WorldWideScience

Sample records for serum samples drawn

  1. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  2. Microcontroller-based system for estimate of calcium in serum samples.

    Science.gov (United States)

    Neelamegam, Periyaswmy; Jamaludeen, Abdul Sheriff; Ragendran, Annamalai; Murugrananthan, Krishanamoorthy

    2010-01-01

    In this study, a microcontroller-based control unit was designed and constructed for the estimation of serum calcium in blood samples. The proposed optoelectronic instrument used a red light emitting diode (LED) as a light source and photodiode as a sensor. The performance of the system was compared with that of a commercial instrument in measuring calcium ion. The quantitative analysis of calcium in a catalyst using arsenazo III as colorimetric reagent was used to test the device. The calibration curve for calcium binding with arsenazo III was drawn to check the range of linearity, which was between 0.1 to 4.5 mM L⁻¹. The limit of detection (LOD) is 0.05 mM L⁻¹. Absorbance changes over the pH range of 2-12 were determined to optimize the assay, with maximum absorption at pH 9.0. Interferences in absorbance from monovalent (K+ and Na+) and divalent (Mg²+) cations were also studied. The results show that the system works successfully.

  3. Metabolite characterization in serum samples from normal healthy ...

    African Journals Online (AJOL)

    Metabolite characterization in serum samples from normal healthy human subjects by 1H and 13C NMR spectroscopy. D Misra, U Bajpai. Abstract. One and two dimensional NMR spectroscopy has been employed to characterize the various metabolites of serum control healthy samples. Two dimensional heteronuclear ...

  4. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  5. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.

    Science.gov (United States)

    Sulaiman, Raashda A; Cornes, Michael P; Whitehead, Simon J; Othonos, Nadia; Ford, Clare; Gama, Rousseau

    2011-11-01

    To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.

  6. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  7. Comparison of miRNA quantitation by Nanostring in serum and plasma samples.

    Directory of Open Access Journals (Sweden)

    Catherine Foye

    Full Text Available Circulating microRNAs that are associated with specific diseases have garnered much attention for use in diagnostic assays. However, detection of disease-associated miRNA can be affected by several factors such as release of contaminating cellular miRNA during sample collection, variations due to amplification of transcript for detection, or controls used for normalization for accurate quantitation. We analyzed circulating miRNA in serum and plasma samples obtained concurrently from 28 patients, using a Nanostring quantitative assay platform. Total RNA concentration ranged from 32-125 μg/ml from serum and 30-220 μg/ml from plasma. Of 798 miRNAs, 371 miRNAs were not detected in either serum or plasma samples. 427 were detected in either serum or plasma but not both, whereas 151 miRNA were detected in both serum and plasma samples. The diversity of miRNA detected was greater in plasma than in serum samples. In serum samples, the number of detected miRNA ranged from 3 to 82 with a median of 17, whereas in plasma samples, the number of miRNA detected ranged from 25 to 221 with a median of 91. Several miRNA such as miR451a, miR 16-5p, miR-223-3p, and mir25-3p were highly abundant and differentially expressed between serum and plasma. The detection of endogenous and exogenous control miRNAs varied in serum and plasma, with higher levels observed in plasma. Gene expression stability identified candidate invariant microRNA that were highly stable across all samples, and could be used for normalization. In conclusion, there are significant differences in both the number of miRNA detected and the amount of miRNA detected between serum and plasma. Normalization using miRNA with constant expression is essential to minimize the impact of technical variations. Given the challenges involved, ideal candidates for blood based biomarkers would be those that are indifferent to type of body fluid, are detectable and can be reliably quantitated.

  8. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  9. Fecal corticosterone reflects serum corticosterone in Florida sandhill cranes.

    Science.gov (United States)

    Ludders, J W; Langenberg, J A; Czekala, N M; Erb, H N

    2001-07-01

    Florida sandhill cranes (Grus canadensis pratensis) were conditioned to confinement 6 hr/day for 7 days. On day 8, each bird's jugular vein was catheterized, blood samples were drawn, and each crane was confined for 6 hr. Using a randomized, restricted cross-over design, cranes were injected intravenously with either 0.9% NaCl solution or ACTH (cosyntropin; Cortrosyn; 0.25 mg). During the 6 hr of confinement, fecal samples (feces and urine) were collected from each of five cranes immediately after defecation. Individual fecal samples were collected approximately at hourly intervals and assayed for corticosterone. We showed previously that serum corticosterone did not vary significantly following saline injection, but peaked significantly 60 min after ACTH injection. Maximal fecal corticosterone concentrations (ng/g) were greater (P cranes under controlled conditions, fecal corticosterone concentration reflects serum corticosterone levels, fecal corticosterone, Grus canadensis pratensis, sandhill cranes, serum corticosterone levels.

  10. Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.

    Science.gov (United States)

    Ferreira, Janita; Camargos, Paulo Augusto Moreira; Clemente, Wanessa Trindade; Romanelli, Roberta Maia de Castro

    2018-01-01

    Neonatal sepsis is the most frequent health care-associated infection in neonatal units. This study aimed to analyze articles on the clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of intravascular catheter-related bloodstream infection (CRBSI) in neonates. A systematic search was performed for studies published from 1987-2017, without language restriction. Observational studies carried out in neonates with CRBSI diagnosed using catheter-drawn blood samples or catheter tip cultures were included. A total of 412 articles were identified in the databases and 10 articles were included. The 7 studies that evaluated central venous catheter tip cultures and cultures of catheter fragments presented sensitivities ranging from 58.5%-100% and specificities ranging from 60%-95.7%. Three studies that evaluated catheter-drawn blood cultures, paired with peripheral blood cultures, reported sensitivity and specificity of 94% and 71% when evaluated for the differential time to positivity. When quantitative evaluation was performed, the sensitivity and specificity were 80% and 99.4%. Most of the studies analyzed cultures from the central venous catheter tip and catheter fragments for the diagnosis of CRBSI in neonatal populations. The results of this review suggest that the analysis of the catheter-drawn blood samples and catheter tip cultures, paired with peripheral blood cultures, are efficient methods for the diagnosis of CRBSI in neonates. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  12. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  13. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  14. Tensile Fracture Behavior of Progressively-Drawn Pearlitic Steels

    Directory of Open Access Journals (Sweden)

    Jesús Toribio

    2016-05-01

    Full Text Available In this paper a study is presented of the tensile fracture behavior of progressively-drawn pearlitic steels obtained from five different cold-drawing chains, including each drawing step from the initial hot-rolled bar (not cold-drawn at all to the final commercial product (pre-stressing steel wire. To this end, samples of the different wires were tested up to fracture by means of standard tension tests, and later, all of the fracture surfaces were analyzed by scanning electron microscopy (SEM. Micro-fracture maps (MFMs were assembled to characterize the different fractographic modes and to study their evolution with the level of cumulative plastic strain during cold drawing.

  15. Radioenzymatic assay for trimethoprim in very small serum samples.

    OpenAIRE

    Yogev, R; Melick, C; Tan-Pong, L

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved.

  16. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  17. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  18. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  19. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  20. Serum concentration of anti-Müllerian hormone is not associated with semen quality

    DEFF Research Database (Denmark)

    Aksglaede, L; Olesen, I A; Carlsen, E

    2018-01-01

    Impaired semen quality is frequent in Western countries and is the main reason or contributing reason in up to 50% of cases of couple infertility. Male factor infertility is mainly determined by examination of semen samples according to the World Health Organization's 2010 guidelines. AMH has both...... autocrine and paracrine properties through a direct effect via the AMH type II receptor and is therefore thought to be involved in spermatogenesis. We aimed to study the association between the serum concentration of AMH and semen quality in a cross-sectional study including 970 young Danish men from...... the general population. All participants provided a semen sample, had a blood sample drawn, underwent a physical examination, and answered a questionnaire including information on lifestyle and medical history. Serum concentrations of reproductive hormones [AMH, luteinizing hormone (LH), follicle...

  1. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  2. Release of muscle α-actin into serum after intensive exercise

    Directory of Open Access Journals (Sweden)

    A Martínez-Amat

    2010-12-01

    Full Text Available Purpose: To study the effects of high-level matches on serum alpha actin and other muscle damage markers in teams of rugby and handball players. Methods: Blood samples were drawn from 23 sportsmen: 13 rugby players and 10 handball players. One sample was drawn with the player at rest before the match and one immediately after the match. Immunoassays were used to determine troponin I, troponin T, LDH, and myoglobin concentrations. Western blot and densitometry were used to measure α-actin concentrations. Muscle injury was defined by a total CK value of > 500 IU/L (Rosalki method. Results: Mean pre- and post-match serum alpha-actin values were, respectively, 7.16 and 26.47 μg/ml in the handball group and 1.24 and 20.04 μg/ml in the rugby team. CPK, LDH and myoglobin but not troponin 1 levels also significantly differed between these time points. According to these results, large amounts of α-actin are released into peripheral blood immediately after intense physical effort. Possible cross-interference between skeletal and cardiac muscle damage can be discriminated by the combined use of α-actin and troponin I. Conclusion: The significant increase in alpha-actin after a high-level match may be a reliable marker for the early diagnosis and hence more effective treatment of muscle injury.

  3. Online Signature Verification on MOBISIG Finger-Drawn Signature Corpus

    Directory of Open Access Journals (Sweden)

    Margit Antal

    2018-01-01

    Full Text Available We present MOBISIG, a pseudosignature dataset containing finger-drawn signatures from 83 users captured with a capacitive touchscreen-based mobile device. The database was captured in three sessions resulting in 45 genuine signatures and 20 skilled forgeries for each user. The database was evaluated by two state-of-the-art methods: a function-based system using local features and a feature-based system using global features. Two types of equal error rate computations are performed: one using a global threshold and the other using user-specific thresholds. The lowest equal error rate was 0.01% against random forgeries and 5.81% against skilled forgeries using user-specific thresholds that were computed a posteriori. However, these equal error rates were significantly raised to 1.68% (random forgeries case and 14.31% (skilled forgeries case using global thresholds. The same evaluation protocol was performed on the DooDB publicly available dataset. Besides verification performance evaluations conducted on the two finger-drawn datasets, we evaluated the quality of the samples and the users of the two datasets using basic quality measures. The results show that finger-drawn signatures can be used by biometric systems with reasonable accuracy.

  4. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  5. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  6. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  7. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review.

    Science.gov (United States)

    Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W

    2017-01-01

    The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n  = 122 papers were included. The proteins S100B ( n  = 66) and NSE ( n  = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n  = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n  = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n  = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be

  8. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-07-01

    Full Text Available BackgroundThe proteins S100B, neuron-specific enolase (NSE, glial fibrillary acidic protein (GFAP, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1, and neurofilament light (NF-L have been serially sampled in serum of patients suffering from traumatic brain injury (TBI in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term “effective half-life” (t1/2 in order to describe the “fall” rate in serum.Materials and methodsThrough searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations.ResultsFollowing screening (10,389 papers, n = 122 papers were included. The proteins S100B (n = 66 and NSE (n = 27 were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1–2 h though possibly of non-cerebral origin. In contrast, the t1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP (n = 18 appears to have t1/2 of about 24–48 h in severe TBI. The protein UCH-L1 (n = 9 presents a t1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L (n = 2 only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use.ConclusionSerial sampling of brain-specific proteins in serum reveals

  9. Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples

    Directory of Open Access Journals (Sweden)

    Samira Moraes Cunha de Mesquita

    2015-06-01

    Full Text Available ABSTRACT. Mesquita S.M.C., Mansur F.J., Nascimento E.R., Barreto M.L. & Kimura L.M.S. [Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples.] Padroniza- ção e aplicação de ELISA indireto para diagnóstico de Mycoplasma bovis em amostras de soro sanguíneo bovino. Revista Brasileira de Medicina Veterinária, 37(2:101-107, 2015. Universidade Federal Fluminense, Faculdade de Veteriná- ria, Rua Vital Brazil Filho, 64, Vital Brazil, Niterói, RJ 24230-340, Brasil. E-mail: samira.veterinaria@gmail.com International researchers presented results indicating frequent involvement of Mycoplasma spp. as a causative agent of mastitis in cattle, associating its presence with significant economic losses to farmers. Mycoplasma bovis is the species most reported and relevant, because it causes more severe disease. The level of antibodies against M. bovis remains high for several months and can be detected by ELISA. The aim of this work was to develop an indirect ELISA with whole cell antigen of M. bovis (strain Donetta PG 45 with subsequent application in bovine blood serum samples for detection of antibodies against M. bovis. The immunization of cows A and B by inoculating an immunogen against M. bovis to obtain hyperimmune blood serum was the first stage of this work, then the stage of standardization of ELISA was proceeded. The concentration of 2 mg of antigen/mL for coating the microtiter plates was decided by statistical analyses. The optical density value 0,2 was determined as the limit of reactivity discrimination of samples (the cut-off point. The hyperimmune blood serum sample of the cow A (collected 30 days after immunization was chosen as the positive control and, the fetal calf serum was chosen as negative control of the assay. In addition, the ideal optimal dilutions found for blood serum samples was 1:400 and for conjugate was 1:10.000 and the substrate used was the ortho

  10. Retrospective analysis of dengue specific IgM reactive serum samples

    OpenAIRE

    Nemai Bhattacharya; Bhaswati Bandyopadhyay; Indranil Bhattacharjee; Hiranmoy Mukherjee; Srabani Talukdar; Ruby Mondal; Netai Pramanick; Goutam Chandra; Amiya K. Hati

    2013-01-01

    Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1) antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: Th...

  11. Effects of sleep deprivation on serum cortisol level and mental health in servicemen.

    Science.gov (United States)

    Song, Hong-Tao; Sun, Xin-Yang; Yang, Ting-Shu; Zhang, Li-Yi; Yang, Jia-Lin; Bai, Jing

    2015-06-01

    This study aimed to investigate the effects of sleep deprivation on serum cortisol level and mental health and explore the correlations between them in servicemen. A total of 149 out of the 207 Chinese servicemen were randomly selected to go through 24hour sleep deprivation, leaving the rest (58) as the control group, before and after which their blood samples were drawn for cortisol measurement. Following the procedure, all the participants were administered the Military Personnel Mental Disorder Prediction Scale, taking the military norm as baseline. The results revealed that the post-deprivation serum cortisol level was positively correlated with the factor score of mania in the sleep deprivation group (rSp=0.415, pSleep deprivation could significantly increase serum cortisol level and may affect mental health in servicemen. The increase of serum cortisol level is significantly related to mania disorder during sleep deprivation. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Low serum vitamin D concentrations in patients with schizophrenia.

    Science.gov (United States)

    Itzhaky, Dganit; Amital, Daniela; Gorden, Katya; Bogomolni, Alisa; Arnson, Yoav; Amital, Howard

    2012-02-01

    Vitamin D is increasingly associated with the pathology of cognition and mental illness. Vitamin D receptors have been detected on neurons that regulate behavior. To assess vitamin D serum concentrations in patients with major depression and schizophrenia as compared to healthy controls and to determine if a correlation exists between serum levels of vitamin D and disease activity. We recruited 50 patients with schizophrenia and compared them to 33 patients with major depression and 50 controls with no major psychopathology. The Positive and Negative Syndrome Scale (PANSS) for schizophrenia and the Hamilton Depression scale for depression were administered on the same day the blood samples were drawn. We used LIAISON 25-OH vitamin D (DiaSorin) immunoassay to measure serum concentrations of 25-OH vitamin D. Lower serum vitamin D concentrations were detected among patients with schizophrenia (15.0 +/- 7.3 ng/ml) compared to patients with depression (19.6 +/- 8.3 ng/ml) and to controls (20.2 +/- 7.8 ng/ml, P vitamin D levels. Serum vitamin D levels were lower in patients with schizophrenia as compared to patients with depression and to healthy controls. No correlation was found between serum concentration and disease activity. Additional studies are needed to elucidate the role of vitamin D in the autoimmune mechanism and in the pathogenesis of schizophrenia.

  13. Serum levels of INSL3, AMH, Inhibin B and Testosterone during pubertal transition in healthy boys

    DEFF Research Database (Denmark)

    Lindhardt Johansen, Marie; Anand-Ivell, Ravinder; Mouritsen, Annette

    2014-01-01

    to luteinizing hormone (LH), follicle-stimulating hormone (FSH), testosterone, inhibin B, and anti-Müllerian hormone (AMH) during puberty in healthy boys.MethodsTen boys were included from the longitudinal part of the COPENHAGEN Puberty Study. Pubertal evaluation, including testicular volume, was performed...... and blood samples drawn every 6 months for 5 years. Serum concentrations of testosterone were determined by a newly developed LC-MS/MS method, and serum concentrations of INSL3, AMH, inhibin B, FSH and LH, respectively, were determined by validated immunoassays.ResultsSerum INSL3 levels increased...... progressively with increasing age, pubertal onset and testicular volume. In six of ten boys, LH increased prior to the first observed increase in INSL3. In the remaining four boys, the increase in LH and INSL3 was observed at the same examination. The increases in serum concentrations of LH, testosterone...

  14. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  15. Resolution of a serum sample mix-up through the use of short tandem repeat DNA typing.

    Science.gov (United States)

    Allen, Robert W; Pritchard, Jane K

    2004-12-01

    A sample mix-up occurred in a tissue procurement laboratory in which aliquots of serum from two tissue donors were accidentally mislabeled. The clues to the apparent mixup involved discrepant Hepatitis C test results. In an attempt to resolve the apparent mix up, DNA typing was performed using serum samples as a possible source of genomic DNA. Two hundred microliter aliquots of two reference sera and aliquots prepared from them were subjected to DNA extraction. PCR amplification of 9 STR loci was performed on the extracts and amplicons were analyzed by capillary electrophoresis. About 1 microg/ml of DNA was recovered from all serum samples and was of sufficient quality to direct the amplification of most, if not all STR loci allowing the mislabeled specimens to be traced to the proper tissue donor. Serum is a useful source of genomic DNA for STR analysis in situations in which such samples are the only source of DNA for testing. Interestingly, one of the tissue donors on life support and repeatedly receiving blood products, exhibited a mixed DNA profile indicative of the presence of DNA from multiple individuals in the bloodstream.

  16. Usefulness of in-house real time PCR for HBV DNA quantification in serum and oral fluid samples.

    Science.gov (United States)

    Portilho, Moyra Machado; Mendonça, Ana Carolina da Fonseca; Bezerra, Cristianne Sousa; do Espirito-Santo, Márcia Paschoal; de Paula, Vanessa Salete; Nabuco, Leticia Cancella; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2018-06-01

    For quantification of hepatitis B virus DNA (HBV DNA), commercial assays are used with serum or plasma samples, but oral fluid samples could be an alternative for HBV diagnosis due to ease of collection. This study aims to develop in-house real time PCR using synthetic curve for HBV DNA quantification for serum and oral fluid samples. Samples were collected from 103 individuals (55 HBsAg reactive and HBV DNA reactive by commercial assay and 48 without HBV markers) and submitted to two in-house real time PCR assays for HBV pre-S/S region with different standard curves: qPCR plasmidial and qPCR synthetic. A total of 27 serum samples were HBV DNA positive by qPCR plasmidial and 40 with qPCR synthetic (72% and 85% of concordance, respectively). Quantitative PCR synthetic presented efficiency of 99% and sensitivity of 2log10 copies/mL. Among oral fluid samples, five and ten were detected using qPCR plasmidial and synthetic, respectively. This study demonstrated that qPCR synthetic using serum samples could be used as alternative for HBV DNA quantification due to its sensitivity. In addition, it was possible to quantify HBV DNA in oral fluid samples suggesting the potential of this specimen for molecular diagnosis of HBV. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. SketchingDIS: Hand-drawn Sketching in HCI

    DEFF Research Database (Denmark)

    Lewis, Makayla; Sturdee, Miriam; Alexander, Jason

    2017-01-01

    DIS: Hand-drawn sketching in HCI' SketchingDIS.wordpress.com, a one-day workshop will bring together researchers from various disciplines that have incorporated hand-drawn sketching into their everyday research practice, to share knowledge and methodologies, generate ideas, practice collaborative sketching...

  18. Serum thromboxane B2 (TXB2 Determination is Influenced by Sample Incubation Temperature in Healthy Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Aleš Jerin

    2009-01-01

    Full Text Available The measurement of serum thromboxane B2 (TXB2 production by platelets is a specific test for assessment of platelet cyclooxygenase (COX-1 activity following administration of non-steroidal anti-inflammatory drugs (NSAIDs. The aim of this study was to investigate the influence of sample incubation at 37 °C for one hour on serum TXB2 concentration in comparison with incubation at room temperature. A total of 54 blood samples for serum TXB2 measurements were collected from six healthy beagle dogs into two separate serum tubes. While one group of tubes was incubated in a 37 °C water bath, the second group of tubes was left to coagulate at room temperature, both for one hour. Serum TXB2 concentrations were measured by ELISA. The mean concentration (± SD of serum TXB2 in the group of samples that were incubated at 37 °C was significantly (P 2 concentration in healthy beagle dogs and demonstrate that validated methods for assessment of COX-1 activity by measurement of serum TXB2 should be used in order to make results more reliable and comparable between different studies. The results of this study might be of great help in planning NSAID studies in dogs by providing the information that TXB2 generation by platelets is influenced profoundly by incubation temperature.

  19. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.

    Science.gov (United States)

    Govorukhina, N I; Reijmers, T H; Nyangoma, S O; van der Zee, A G J; Jansen, R C; Bischoff, R

    2006-07-07

    Discovery of biomarkers is a fast developing field in proteomics research. Liquid chromatography coupled on line to mass spectrometry (LC-MS) has become a powerful method for the sensitive detection, quantification and identification of proteins and peptides in biological fluids like serum. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomics studies. To perform future comparative analyses of samples from a serum bank of cervical cancer patients in a longitudinal and cross-sectional manner, methodology based on the depletion of high-abundance proteins followed by tryptic digestion and LC-MS has been developed. Two sample preparation methods were tested in terms of their efficiency to deplete high-abundance serum proteins and how they affect the repeatability of the LC-MS data sets. The first method comprised depletion of human serum albumin (HSA) on a dye ligand chromatographic and immunoglobulin G (IgG) on an immobilized Protein A support followed by tryptic digestion, fractionation by cation-exchange chromatography, trapping on a C18 column and reversed-phase LC-MS. The second method included depletion of the six most abundant serum proteins based on multiple immunoaffinity chromatography followed by tryptic digestion, trapping on a C18 column and reversed-phase LC-MS. Repeatability of the overall procedures was evaluated in terms of retention time and peak area for a selected number of endogenous peptides showing that the second method, besides being less time consuming, gave more repeatable results (retention time: <0.1% RSD; peak area: <30% RSD). Application of an LC-MS component detection algorithm followed by principal component analysis (PCA) enabled discrimination of serum samples that were spiked with horse heart cytochrome C from non-spiked serum and the detection of a concentration trend, which correlated to the amount of spiked horse heart

  20. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  1. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  2. Physical properties of drawn very low density polyethylene films

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.S. [Yeungnam University, Kyongsan (Korea, Republic of); Lee, J.Y. [Korea Institute of Footwear and Leather Technology, Pusan (Korea, Republic of)

    1998-05-01

    Very low density polyethylene (VLDPE) films were prepared by quenching the pressed melt in ice water. The films were drawn with universal testing machine under constant temperature at four different temperatures, 30, 60, 80, and 110 {sup o} C. Thermal, mechanical properties, grossity, and gas permeability of the drawn VLDPE films as a function of draw ratio were investigated to examine their applicability to packaging. The films showed tow melting peaks, i.e., low temperature endotherm (LTE) and high temperature endotherm (HTE). The melting temperatures were increased with the draw ratio and the drawing temperature. The mechanical properties of the VLDPE film drawn at 80 {sup o} C were superior to those drawn at 110 {sup o} C. The grossity and gas permeability of the VLDPE film drawn at 110 {sup o} C were found to be best among the drawn films.

  3. Quality assesment for the analysis of PCDDs/PCDFs in individual human serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Perez, F [IIQAB-CSIC, Barcelona (Spain). Dept. of Ecotechnologies, Lab. of Dioxins; Abad, E; Llerena, J J; Caixach, J; Rivera, J

    2004-09-15

    The aim of this work was to optimise a relevant methodology for the ultratrace analysis of PCDDs/PCDFs in individual human serum samples. In order to carry out the study, different strategies including the elaboration of quality control samples, parallel sample analysis, control blanks and a number of quality assurance measures were implemented as analytical current practices. Some of the main drawbacks in the analysis of PCDDs/PCDFs in these kind of samples come from two conflicting aspects: the small sample size and the low levels expected to be found. Taking this into account, an unavoidable compromise between the sample amount and the minimum analytical requirements, mainly the detection limit (LOD), is mandatory. To reach this goal C{sub 18} solid phase extraction was used to remove the analytes from the matrix. Clean up was performed by solid-liquid adsorption chromatography using a variety of adsorbents. Instrumental analysis was achieved by high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). Finally, the optimised methodology was applied to evaluate the potential impact in general population living in the surroundings of an obsolete municipal waste incinerator plant (MWI). Thus, more than 400 individuals serum samples potentially exposed to the emission of the incinerator and people not exposed were considered in this study.

  4. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  5. Studies of the remagnetization process in cold drawn Fe-rich thin amorphous wires

    International Nuclear Information System (INIS)

    Gawronski, P.; Zhukov, A.P.; Blanco, J.M.; Gonzalez, J.; Zhukova, V.; Kulakowski, K.

    2007-01-01

    Results on local hysteresis loops for Fe-rich amorphous cold-drawn wires with the sample lengths of 30 mm and 70 mm under applied stress, σ, up to 1300 MPa are reported. For both lengths, the magnetization, M, increases with σ and the coercive field, H C , decreases. Near the wire end, M results to be larger than at the wire center, and H C sharply decreases. This reduction is eliminated if the applied stress is large enough. It is assumed, that the magnetic configuration at the wire end for the cold-drawn wires is different from the other wires families

  6. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  7. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  8. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  9. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  10. Chemometrics enhanced HPLC-DAD performance for rapid quantification of carbamazepine and phenobarbital in human serum samples.

    Science.gov (United States)

    Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh

    2014-02-01

    This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  11. Predictors of Serum 25-Hydroxyvitamin D Concentrations among a Sample of Egyptian Schoolchildren

    Directory of Open Access Journals (Sweden)

    Mones M. Abu Shady

    2016-01-01

    Full Text Available Objective. To assess the level of 25-hydroxyvitamin D status among a sample of Egyptian schoolchildren and to evaluate predictors of deficiency and insufficiency. Subjects and Methods. A cross-sectional study comprising 200 prepubescent schoolchildren aged from 9 to 11 years was performed. A questionnaire including frequency of midday sun exposure, milk intake, physical activity, and level of maternal education was taken. Body mass index (BMI was calculated; serum 25-hydroxyvitamin D [25(OHD], serum calcium, phosphorus, and parathyroid hormone were measured. Results. Vitamin D deficiency [serum 25(OHD < 20 ng/mL] was detected in 11.5% of subjects while its insufficiency (serum 25(OHD is between 20 and 29.9 ng/mL was detected in 15%. Results revealed that obesity, low physical activity, low sun exposure, and low maternal education level are significant predictors of insufficiency, though female gender, low maternal education level, and low milk intake are significant predictors of deficiency. Lower serum phosphorus and higher serum parathyroid hormone were significantly associated with both deficiency and insufficiency (p<0.05. Conclusion. Vitamin D deficiency and insufficiency are common among schoolchildren in Egypt. Food fortification, vitamin D supplementation, and increasing maternal awareness about the importance of physical activity and exposure of their children to ultraviolet light may help to overcome this problem.

  12. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

    . This study aimed to test that theory. Method: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. Results: We found statistically significant chromium contamination from the steel needle with mean differences......  Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bias...... between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline significant...

  13. A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies

    Directory of Open Access Journals (Sweden)

    Elodie Jobard

    2016-12-01

    Full Text Available The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies.

  14. Soluble CD44 concentration in the serum and peritoneal fluid samples of patients with different stages of endometriosis.

    Science.gov (United States)

    Mashayekhi, Farhad; Aryaee, Hadis; Mirzajani, Ebrahim; Yasin, Ashraf Ale; Fathi, Abdolsatar

    2015-09-01

    Endometriosis is a gynecological disease defined by the histological presence of endometrial glands and stroma outside the uterine cavity, most commonly implanted over visceral and peritoneal surface within the female pelvis. CD44 is a membrane protein expressed by human endometrial cells, and it has been shown to promote the adhesion of endometrial cells. The aim of this study was to determine the levels of soluble CD44 (sCD44) in the serum and peritoneal fluid (PF) samples of patients with different stages of endometriosis. 39 PF and serum samples from normal healthy and 130 samples from different stages of patients with endometriosis (33 cases of stage I, 38 stage II, 30 stage III and 29 stage IV) were included in this study. Total protein concentration (TPC) and the level of s-cMet in the serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay, respectively. No significant change in the TPC was seen in the serum of patients with endometriosis when compared to normal controls. Results obtained demonstrated that all serum and peritoneal fluid samples, presented sCD44 expression, whereas, starting from stages I to IV endometriosis, a significant increase of sCD44 expression was observed as compared to control group. The results of this study show that a high expression of sCD44 is correlated with advanced stages of endometriosis. It is also concluded that the detection of serum and/or peritoneal fluid sCD44 may be useful in classifying endometriosis.

  15. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  16. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  17. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  18. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  19. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  20. A comparative study of some physico-chemical properties of human serum albumin samples from different sources--I : Some physico-chemical properties of isoionic human serum albumin solutions

    NARCIS (Netherlands)

    Dröge, J.H.M.; Janssen, L.H.M.; Wilting, J.

    1982-01-01

    Human serum albumin samples from different sources were investigated. The fatty acid content of the albumin before and after deionization on a mixed bed ion-exchange column varied from sample to sample. When an albumin sample from one source was deionized under standard conditions the amount of

  1. Association of high fetuin-B concentrations in serum with fertilization rate in IVF: a cross-sectional pilot study.

    Science.gov (United States)

    Floehr, Julia; Dietzel, Eileen; Neulen, Josef; Rösing, Benjamin; Weissenborn, Ute; Jahnen-Dechent, Willi

    2016-03-01

    Is serum fetuin-B associated with the fertilization rate in in vitro fertilization (IVF)? Serum fetuin-B increased during IVF cycles when oocytes could be fertilized while remained unchanged in fertilization failure. Fetuin-B deficiency in mice causes premature zona pellucida hardening mediated by the zona protease ovastacin. Thus fetuin-B deficiency renders females infertile. We determined the human serum fetuin-B reference range, studying longitudinally, over the course of one month, five male and seven female volunteers without hormone treatment and four female volunteers on varying hormonal contraception. We sampled blood and determined serum fetuin-B, luteinizing hormone (LH), estradiol (E2) and progesterone (P4). In addition, we determined serum fetuin-B and estradiol in eight women undergoing intracytoplasmatic sperm injection (ICSI, nine ICSI cycles) and 19 women undergoing IVF (21 IVF cycles) after ovarian stimulation with recombinant human follicular stimulating hormone (rFSH) and/or a combined medication of FSH and LH. At least three blood samples were analyzed in each cycle. We compared serum fetuin-B and follicular fluid fetuin-B in nine patients by measuring follicular fetuin-B in pooled follicular fluid, and in fluid obtained from individual follicles. Samples were drawn from January 2012 to March 2014. All volunteers and patients gave informed consent. Fetuin-B was measured employing a commercial sandwich enzyme-linked immunosorbent assay. Serum fetuin-B was determined as duplicates in 5 male (34 ± 14.6 years) and 11 female volunteers (29.4 ± 4.1 years) as well as in female volunteers on hormonal contraception (30.0 ± 6.5 years). The duplicate standard deviation was 4.0 ± 2.3%. The contraceptive drugs were mono or combined preparations containing 0-0.03 mg ethinyl estradiol, and 0.15-3.0 mg of various progestins. In addition, serum fetuin-B was determined as triplicates in 27 female patients undergoing conventional IVF (19) or ICSI (8). The

  2. Quantitative profiling of serum samples using TMT protein labelling, fractionation and LC-MS/MS.

    Science.gov (United States)

    Sinclair, John; Timms, John F

    2011-08-01

    Blood-borne biomarkers are urgently required for the early detection, accurate diagnosis and prognosis of disease. Additionally, improved methods of profiling serum and plasma proteins for biomarker discovery efforts are needed. Herein, we report a quantitative method based on amino-group labelling of serum proteins (rather than peptides) with isobaric tandem mass tags (TMT) and incorporating immune-based depletion, gel-based and strong anion exchange separation of proteins prior to differential endoproteinase treatment and liquid chromatography tandem mass spectrometry. We report a generally higher level of quantitative coverage of the serum proteome compared to other peptide-based isobaric tagging approaches and show the potential of the method by applying it to a set of unique samples that pre-date the diagnosis of pancreatic cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    Science.gov (United States)

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  4. Clinical, radiological and molecular diagnosis correlation in serum samples from patients with osteoarticular tuberculosis

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2014-07-01

    Conclusions: Nested PCR in serum samples is a rapid, highly sensitive and specific modality for OTB detection. PCR should be performed in addition to clinical evaluation, imaging studies, acid-fast bacilli staining, culture and histopathology diagnosis, if possible.

  5. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  6. Pakistanis living in Oslo have lower serum 1,25-dihydroxyvitamin D levels but higher serum ionized calcium levels compared with ethnic Norwegians. The Oslo Health Study

    Science.gov (United States)

    Holvik, Kristin; Meyer, Haakon E; Søgaard, Anne Johanne; Haug, Egil; Falch, Jan A

    2007-01-01

    Background Persons of Pakistani origin living in Oslo have a much higher prevalence of vitamin D deficiency and secondary hyperparathyroidism but similar bone mineral density compared with ethnic Norwegians. Our objective was to investigate whether Pakistani immigrants living in Oslo have an altered vitamin D metabolism by means of compensatory higher serum levels of 1,25-dihydroxyvitamin D (s-1,25(OH)2D) compared with ethnic Norwegians; and whether serum levels of ionized calcium (s-Ca2+) differ between Pakistanis and Norwegians. Methods In a cross-sectional, population-based study venous serum samples were drawn from 94 Pakistani men and 67 Pakistani women aged 30–60 years, and 290 Norwegian men and 270 Norwegian women aged 45–60 years; in total 721 subjects. Results Pakistanis had lower s-1,25(OH)2D compared with Norwegians (p Oslo with low vitamin D status and secondary hyperparathyroidism have lower s-1,25(OH)2D compared with ethnic Norwegians. However, the Pakistanis have higher s-Ca2+. The cause of the higher s-Ca2+ in Pakistanis in spite of their higher iPTH remains unclear. PMID:17945003

  7. Correlation of serum magnesium with dyslipidemia in patients on maintenance hemodialysis

    Directory of Open Access Journals (Sweden)

    Muhammad Rafique Ansari

    2012-01-01

    Full Text Available This study was performed to determine the correlation between serum magnesium (Mg and dyslipidemia in patients on maintenance hemodialysis (MHD. This hospital-based cross-sectional observational study was conducted at the Department of Nephro-Urology, Liaquat University Hospital, Hyderabad, Pakistan, from April 2008 to June 2008. Fifty patients with end-stage kidney disease on MHD treatment (33 males and 17 females were studied. The mean duration on HD was 7.58 ± 2.05 years, with frequency being two to three sessions/week, and each session lasted for four hours. After obtaining informed written consent, the general information of each patient was recorded on a proforma. After overnight fasting, blood samples was drawn from the arterio-venous fistula for lipid profile, lipoprotein, serum Mg, serum creatinine, blood urea, serum calcium and serum phosphorus. Dyslipidemia was defined as presence of total cholesterol (TC, triglyceride (TG or low-density lipoprotein (LDL levels more then 95 th percentile for age and gender or high-density lipoprotein (HDL levels less then 35 mg/dL. Descriptive and inferential statistical analyses were performed using SPSS version 16.0. The mean age of the study patients was 45.68 ± 13.97 years. There was a significant positive correlation between serum Mg and serum lipoprotein-a (LP-a (r = 0.40, P < 0.007, serum HDL (r = 0.31, P < 0.01 and serum TG (r = 0.35, P < 0.005. There was no significant correlation between serum Mg and serum LDL-c and serum TC. The serum TG and LP-a levels were significantly increased while HDL-c was significantly lower in MHD patients. The serum TC, LDL-c and very low-density lipoprotein-c were not significantly elevated. We conclude that patients with chronic kidney disease undergoing MHD show positive correlation between serum Mg and serum HDL, LP-a and TG. The abnormalities of lipid metabolism, such as hyper-triglyceridemia, elevated LP-a and low HDL-c, could contribute to

  8. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  9. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  10. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    Metabonomics offers a distinct advantage over other tests as it can be ... Metabolic profiling in heart disease has also been successfully ... resonances of the small metabolites showing fingerprints of serum metabolomic profile (Figure. 3).

  11. Ultratrace analysis of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in human serum and cerebrospinal fluid (CSF) samples

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K.; Watanabe, K.; Takemori, H. [Shimadzu Techno Research, Inc., Kyoto (Japan); Shoda, T. [Ehime Univ. Medical Research Center, Matsuyama (Japan); Kuroda, Y. [Tokyo Metropolitan Inst. for Neuroscience, Tokyo (Japan)

    2004-09-15

    In the present study, we established pretreatment and high sensitivity analytical method of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in serum and cerebrospinal fluid (CSF) of humans for the first time. Analyzing serum and CSF samples from humans found unique because PCBs behavior and metabolism could be discerned. Furthermore, so far studies reported concentrations of OH-PCBs in wildlife samples obtained by HRGC-LRMS or GC-ECD data. In this study, we established cleanup and analytical methods by high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) using 1 mL of sample. Mainly, total PCBs and OH-PCBs in the CSF were extracted by specialized developed method. Using this method, PCBs and OH-PCBs could be determined swiftly. Based on this method, major OH-PCB congeners were detected from human, serum, CSF, control serum and Rhesus monkey plasma. Present methodology developed based on the isotope dilution technique using OH-PCBs standard and thus we suggest the present methodology could apply for ultra trace analysis of OHPCBs as well as total PCBs in human samples.

  12. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  13. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    Science.gov (United States)

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from studies. We confirmed from the relationships between questionnaire results and the PFC concentrations in the serum samples, that food is one of the important contribution factors of human exposure to PFCs. However, there were no correlations between the PFC concentrations in the one day composite diet samples and the serum samples, because a one day composite diet sample is not necessarily representative of a person's long-term diet and because of the small number of samples taken. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Quantitation of 14C-oxaliplatin concentrations in human serum samples by using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kobayashi, Takeshi; Toyoguchi, Teiko; Kato, Kazuhiro; Tokanai, Fuyuki; Shiraishi, Tadashi

    2013-01-01

    The understanding of human pharmacokinetics is important for development of new drugs. Microdosing studies have been proposed as means of obtaining human pharmacokinetics information at early stages of drug development. Accelerator mass spectrometry (AMS) has high detection sensitivity and is expected to play an important role in microdose trials. In this study, we used the AMS microdosing facility at Yamagata University to measure the concentration of 14 C in 14 C-oxaliplatin-spiked serum samples. The calibration curve of 14 C concentration in serum was linear, and the correlation coefficient was 0.9994. The precision, accuracy, and stability values obtained (freeze and thaw cycles, and short- and long-term stability) satisfied the criteria. The mean background 14 C concentrations in samples of 6 healthy Japanese volunteers were 1.635dpm/mL in blood and 0.56dpm/mL in plasma. These results suggest the suitability of AMS-based quantitation for analyzing samples from microdosing studies. (author)

  15. The accuracy of serum interleukin-6 and tumour necrosis factor as markers for ovarian torsion.

    Science.gov (United States)

    Cohen, S B; Wattiez, A; Stockheim, D; Seidman, D S; Lidor, A L; Mashiach, S; Goldenberg, M

    2001-10-01

    The aim of this study was to investigate a possible role for interleukin-6 (IL-6) and tumour necrosis factor (TNF-alpha) as pre-operative markers for the diagnosis of ovarian torsion. Twenty consecutive patients admitted to the gynaecological emergency room with suspected clinical diagnosis of ovarian torsion were prospectively assigned to the study. Blood samples were drawn pre-operatively and examined for serum concentrations of IL-6 and TNF-alpha. Surgeons were blinded to laboratory results prior to laparoscopy. The pre-operative diagnosis of ovarian torsion was confirmed during an urgent diagnostic laparoscopy in 8 (40%) patients. The surgical diagnosis among the remaining 12 patients was a large ovarian cyst not in torsion. In six out of eight (75.0%) patients with ovarian torsion serum IL-6 concentrations were elevated. None of the 12 patients without torsion had elevated serum IL-6 concentrations. This difference was statistically significant (P < 0.001). There was no significant difference in the proportion of women with elevated serum TNF-alpha concentrations, two of eight (25.0%) patients with torsion and four of 12 (33.3%) control cases. Elevated serum IL-6 concentrations, but not serum TNF-alpha concentrations, were significantly associated with the occurrence of ovarian torsion. In patients with vague clinical signs of ovarian torsion, serum IL-6 might help to distinguish which patients should undergo diagnostic laparoscopy.

  16. The relationship between serum total testosterone and free testosterone levels with serum hemoglobin and hematocrit levels: a study in 1221 men.

    Science.gov (United States)

    Shin, Yu Seob; You, Jae Hyung; Cha, Jai Seong; Park, Jong Kwan

    2016-12-01

    To investigate the relationship between serum total testosterone (TT) and free testosterone (FT) levels in men with anemia. We reviewed the records of 1221 subjects between March 2009 and December 2014. All the subjects' blood samples were drawn for TT and FT assays. Their serum hemoglobin (Hb) and serum hematocrit (Hct) levels were measured. The primary objective of our study was to investigate the association between TT and FT levels with Hb and Hct levels. The mean age was 59.82 ± 12.71 years. The mean TT and FT levels were 4.54 ± 2.02 ng/mL and 10.63 ± 3.69 pg/mL, respectively. The mean Hb and Hct levels were 14.72 ± 1.34 g/dL and 43.11 ± 3.75%, respectively. Subjects with low TT (<2.35 ng/mL) had low Hb and Hct levels (p < 0.001, p < 0.001, respectively). TT was positively associated with FT, Hb, and Hct. TT and FT levels were significantly lower in older men. Subjects with low TT and FT levels had low Hb and Hct levels. This suggests that TT and FT play a significant role in erythropoiesis. Testosterone replacement therapy may be effective in men with hypogonadism to reduce the incidence of anemia.

  17. Frequency of deaths in hepatitis C virus infected hepatocellular carcinoma patients and its relationship with raised serum alpha-fetoprotein levels.

    Science.gov (United States)

    Shaikh, Fida Hussain; Zeb, Shaista; Chandio, Sultan Ahmed; Munaf, Alvina; Ghori, Muhamad Aamir; Memon, Mohammad Sadik; Burney, Asif Ali

    2016-01-01

    To determine the frequency of deaths in hepatitis C virus infected hepatocellular carcinoma patients, and its relationship with raised serum alpha-fetoprotein levels. The cross-sectional study was conducted at Isra University Hospital, Hyderabad, Pakistan, between March 2013 and April 2014, and comprised all patients diagnosed with hepatitis C virus and hepatocellular carcinoma over 30 years ofage. Blood sample was drawn for the measurement of serum Alfa fetoprotein levels. Data was analysed using SPSS 16. The mean age of the 165 patients was55.49±11.67 years. The mean tumour size was 5.63 ± 2.14cm. Of the total, 31(18.8%) patients had tumour size 5cm. The mean serum Alfa fetoprotein level was 7641.0±3665.32 IU/ml. Overall mortality rate was 70(41.9%). Tumour size >5cm was significantly associated with mortality (p=0.016). Serum Alfa fetoprotein levels were a useful tool for the detection of hepatocellular carcinoma in hepatitis C virus patients.

  18. Prediction of grain deformation in drawn copper wire

    OpenAIRE

    Chang Chao-Cheng; Wang Zi-Wei; Huang Chien-Kuo; Wu Hsu-Fu

    2015-01-01

    Most copper wire is produced using a drawing process. The crystallographic texture of copper wire, which is strongly associated with grain deformation, can have a profound effect on the formability and mechanical and electrical properties. Thus, the ability to predict grain deformation in drawn copper wire could help to elucidate the evolution of microstructure, which could be highly valuable in product design. This study developed a novel method for predicting grain deformation in drawn copp...

  19. Accuracy of cotinine serum test to detect the smoking habit and its association with periodontal disease in a multicenter study.

    Science.gov (United States)

    Duque, A; Martínez, P-J; Giraldo, A; Gualtero, D-F; Ardila, C-M; Contreras, A; Duarte, S; Lafaurie, G-I

    2017-07-01

    The validity of the surveys on self-reported smoking status is often questioned because smokers underestimate cigarette use and deny the habit. It has been suggested that self-report should be accompanied by cotinine test. This report evaluates the usefulness of serum cotinine test to assess the association between smoking and periodontal status in a study with a large sample population to be used in studies with other serum markers in epidemiologic and periodontal medicine researches. 578 patients who were part of a multicenter study on blood biomarkers were evaluated about smoking and its relation to periodontal disease. Severity of periodontal disease was determinate using clinical attachment loss (CAL). Smoking was assessed by a questionnaire and a blood sample drawn for serum cotinine determination. The optimal cut-off point for serum cotinine was 10 ng/ml. Serum cotinine showed greater association with severity of CAL than self-report for mild-moderate CAL [OR 2.03 (CI95% 1.16-3.53) vs. OR 1.08 (CI95% 0.62-1.87) ] advanced periodontitis [OR 2.36 (CI95% 1.30- 4.31) vs. OR 2.06 (CI95% 0.97-4.38) ] and extension of CAL > 3 mm [ OR 1.78 (CI95% 1.16-1.71) vs. 1.37 (CI95% 0.89-2.11)]. When the two tests were evaluated together were not shown to be better than serum cotinine test. Self-reported smoking and serum cotinine test ≥ 10ng/ml are accurate ,complementary and more reliable methods to assess the patient's smoking status and could be used in studies evaluating serum samples in large population and multicenter studies. The serum cotinine level is more reliable to make associations with the patient's periodontal status than self-report questionnaire and could be used in multicenter and periodontal medicine studies.

  20. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  1. Pencil drawn strain gauges and chemiresistors on paper.

    Science.gov (United States)

    Lin, Cheng-Wei; Zhao, Zhibo; Kim, Jaemyung; Huang, Jiaxing

    2014-01-22

    Pencil traces drawn on print papers are shown to function as strain gauges and chemiresistors. Regular graphite/clay pencils can leave traces composed of percolated networks of fine graphite powders, which exhibit reversible resistance changes upon compressive or tensile deflections. Flexible toy pencils can leave traces that are essentially thin films of graphite/polymer composites, which show reversible changes in resistance upon exposure to volatile organic compounds due to absorption/desorption induced swelling/recovery of the polymer binders. Pencil-on-paper devices are low-cost, extremely simple and rapid to fabricate. They are light, flexible, portable, disposable, and do not generate potentially negative environmental impact during processing and device fabrication. One can envision many other types of pencil drawn paper electronic devices that can take on a great variety of form factors. Hand drawn devices could be useful in resource-limited or emergency situations. They could also lead to new applications integrating art and electronics.

  2. Human motion retrieval from hand-drawn sketch.

    Science.gov (United States)

    Chao, Min-Wen; Lin, Chao-Hung; Assa, Jackie; Lee, Tong-Yee

    2012-05-01

    The rapid growth of motion capture data increases the importance of motion retrieval. The majority of the existing motion retrieval approaches are based on a labor-intensive step in which the user browses and selects a desired query motion clip from the large motion clip database. In this work, a novel sketching interface for defining the query is presented. This simple approach allows users to define the required motion by sketching several motion strokes over a drawn character, which requires less effort and extends the users’ expressiveness. To support the real-time interface, a specialized encoding of the motions and the hand-drawn query is required. Here, we introduce a novel hierarchical encoding scheme based on a set of orthonormal spherical harmonic (SH) basis functions, which provides a compact representation, and avoids the CPU/processing intensive stage of temporal alignment used by previous solutions. Experimental results show that the proposed approach can well retrieve the motions, and is capable of retrieve logically and numerically similar motions, which is superior to previous approaches. The user study shows that the proposed system can be a useful tool to input motion query if the users are familiar with it. Finally, an application of generating a 3D animation from a hand-drawn comics strip is demonstrated.

  3. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Evaluation of nested polymerase chain reaction for the early detection of Leptospira spp. DNA in serum samples from patients with leptospirosis.

    Science.gov (United States)

    Blanco, Roberta Morozetti; Romero, Eliete Caló

    2014-04-01

    The aim of this study was to analyse the nested polymerase chain reaction (nested PCR) in human serum samples of patients with clinical manifestations of leptospirosis. The cases of leptospirosis were defined by the microagglutination test (MAT). The samples were collected in 2010. Of 1042 serum samples collected from 521 patients, 28 (5.4%) were considered positive cases of leptospirosis, and 493 (94.6%) were negative. Twenty-three confirmed cases had no MAT-detectable antibodies in the acute sample (mean of 5.6 days after onset). Nested PCR was positive in 22/23 (95.7%) patients during the acute phase of the disease, with negative results by MAT. Nested PCR was negative in all convalescent serum samples with positive results by MAT. All negative cases of leptospirosis were negative by nested PCR. The nested PCR is an alternative diagnostic tool for early detection of leptospires in sera during the first 7 days of the disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  6. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  7. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  8. Correlation of Cadmium and Magnesium in the Blood and Serum Samples of Smokers and Non-Smokers Chronic Leukemia Patients.

    Science.gov (United States)

    Khan, Noman; Afridi, Hasan Imran; Kazi, Tasneem Gul; Arain, Muhammad Balal; Bilal, Muhammad; Akhtar, Asma; Khan, Mustafa

    2017-03-01

    It was studied that cancer-causing processes are related with the disproportions of essential and toxic elements in body tissues and fluid. The purpose of the current study was to evaluate the levels of magnesium (Mg) and cadmium (Cd) in serum and blood samples of smokers and nonsmokers who have chronic myeloid (CML) and lymphocytic (CLL) leukemia, age ranged 31-50 years. For comparative study, age-matched smokers and nonsmoker males were chosen as controls/referents. The levels of elements in patient were analyzed before any treatment by atomic absorption spectrophotometer, after microwave assisted acid digestion. The validation of the method was done by using certified reference materials of serum and blood samples. The resulted data indicated that the adult male smokers and nonsmokers have two- to fourfold higher levels of Cd in the blood and sera samples as compared to the referents (p blood and serum samples of both types of leukemia patients as related to referent values. The resulted data indicates significant negative correlation among Mg and Cd in leukemia patients and smoker referents. Further studies are needed to clarify the role of these elements in pathogenesis of chronic leukemia.

  9. Are samples drawn from Mechanical Turk valid for research on political ideology?

    Directory of Open Access Journals (Sweden)

    Scott Clifford

    2015-12-01

    Full Text Available Amazon’s Mechanical Turk (MTurk is an increasingly popular tool for the recruitment of research subjects. While there has been much focus on the demographic differences between MTurk samples and the national public, we know little about whether liberals and conservatives recruited from MTurk share the same psychological dispositions as their counterparts in the mass public. In the absence of such evidence, some have argued that the selection process involved in joining MTurk invalidates the subject pool for studying questions central to political science. In this paper, we evaluate this claim by comparing a large MTurk sample to two benchmark national samples – one conducted online and one conducted face-to-face. We examine the personality and value-based motivations of political ideology across the three samples. All three samples produce substantively identical results with only minor variation in effect sizes. In short, liberals and conservatives in our MTurk sample closely mirror the psychological divisions of liberals and conservatives in the mass public, though MTurk liberals hold more characteristically liberal values and attitudes than liberals from representative samples. Overall, our results suggest that MTurk is a valid recruitment tool for psychological research on political ideology.

  10. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  11. Slurry sampling in serum blood for mercury determination by CV-AFS

    International Nuclear Information System (INIS)

    Aranda, Pedro R.; Gil, Raul A.; Moyano, Susana; De Vito, Irma; Martinez, Luis D.

    2009-01-01

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 μg L -1 Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L -1 and the relative standard deviation was 3.9% at levels around of 0.4 μg L -1 Hg

  12. Effect of body mass index on serum leptin levels

    International Nuclear Information System (INIS)

    Paul, R.F.; Hassan, M.; Nazar, H.S.

    2012-01-01

    Background: Leptin is product of ob gene, an adipose tissue derived hormone that plays a key role in the regulation of body fat mass by regulating appetite and metabolism while balancing energy intake and energy expenditure. The objective of the study was to evaluate possible association between serum leptin levels and Body Mass Index (BMI) of gender in adult age group. Methods: Two-hundred-seventy subjects aged 20-50 years were randomly selected from general population of Abbottabad. The subjects were grouped on the basis on BMI (89 normal, 92 overweight, and 89 obese). After complete evaluation, demographic data was recorded and BMI. Non-fasting venous blood samples were drawn to measure serum leptin and serum glucose levels. The data were analysed using SPSS-15 calculating mean, percentage, independent t-test and chi-square test. Correlation and regression curve analysis were obtained, and p and r values were calculated. Results: Serum leptin levels and differences between genders were significant in all body mass indices. For normal BMI group the mean values for leptin were 2.6+-1.5 gamma g/ml in men, and 17.3+9-10.2 gamma g/ml for women. For Group-2 mean leptin levels in men were 9.9+-6.8 gamma g/ml and in women were 34.8+-13.6 gamma g/ml. For Group-3 BMI comprising obese subjects mean values for men were 21.3+-14.2 gamma g/ml and for women were 48.21+-21.2 gamma g/ml (p<0.001). Conclusion: A progressive increase in serum leptin concentration was observed with an increase in BMI. Significant difference between leptin concentrations in either gender was found in normal, overweight and obese subjects. (author)

  13. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of

  14. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  15. Substructural evolution during cyclic torsion of drawn low carbon steel bars

    International Nuclear Information System (INIS)

    Correa, E.C.S.; Aguilar, M.T.P.; Monteiro, W.A.; Cetlin, P.R.

    2006-01-01

    Strain softening effects have been previously observed in drawn low carbon steel bars as a result of cyclic torsion experiments. In this paper, the substructural aspects related to the phenomenon have been investigated. Single pass drawn bars were subjected to a quarter, to a half, to a full torsion cycle and to 10 such cycles. Transmission electron microscopy revealed the development of extended microbands crossing the former dislocation arrangement of the drawn metal, which evolves to a rectangular shaped subgrains structure as torsion deformation is conducted

  16. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... with mean differences between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline...

  17. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  18. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  19. Microstructure and strengthening mechanisms in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andy; Huang, Xiaoxu

    2011-01-01

    Strengthening mechanisms and strength–structure relationships have been analyzed in a cold-drawn pearlitic steel with a structural scale in the nanometer range and a flow stress of about 3.5GPa. The wires have been drawn up to a strain of 3.7 and the structures analyzed and quantified by transmis......Strengthening mechanisms and strength–structure relationships have been analyzed in a cold-drawn pearlitic steel with a structural scale in the nanometer range and a flow stress of about 3.5GPa. The wires have been drawn up to a strain of 3.7 and the structures analyzed and quantified...... by transmission electron microscopy and high resolution electron microscopy. The mechanical properties have been determined by tensile testing. It is found that the interlamellar spacing and the thickness of the cementite lamellae are reduced in accordance with the changes in wire diameter up to a strain of 2...... at the ferrite/cementite interface. Three strengthening mechanisms have been analyzed: (i) boundary strengthening, (ii) dislocation strengthening and (iii) solid solution hardening. The individual and combined contributions, based on an assumption of linear additivity, of these mechanisms to the wire strength...

  20. Effects of γ-irradiation and thermal treatment of crystallinity of drawn HDPE

    International Nuclear Information System (INIS)

    Liu Zhanjun; Silverman, J.

    1997-01-01

    The effect of absorbed dose irradiated in vacuum and air on the crystallinity of drawn HDPE was studied. Experimental results show that up to 250 kGy of absorbed dose when irradiated in vacuum, the crystallinity of drawn HDPE is decreased from about 75% to about 71%, and then the increase of absorbed dose until 1000 kGy has no further effect in lowering the crystallinity; when irradiated in air, an absorbed dose of 1000 kGy has no effect on the crystallinity of drawn HDPE. The effect of temperature of thermal treatment on the crystallinity of unirradiated drawn HDPE was also investigated. At first, the crystallinity is increased with the increase of temperature of thermal treatment, at about 120 degree C, it reaches the maximum value, and then it is rapidly lowered with the further increase of temperature of thermal treatment. Based on the existence of a lot of voids and lattice defects inside the drawn HDPE, the above experimental results were explained

  1. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  2. High positive predictive value of Gram stain on catheter-drawn blood samples for the diagnosis of catheter-related bloodstream infection in intensive care neonates.

    Science.gov (United States)

    Deleers, M; Dodémont, M; Van Overmeire, B; Hennequin, Y; Vermeylen, D; Roisin, S; Denis, O

    2016-04-01

    Catheter-related bloodstream infections (CRBSIs) remain a leading cause of healthcare-associated infections in preterm infants. Rapid and accurate methods for the diagnosis of CRBSIs are needed in order to implement timely and appropriate treatment. A retrospective study was conducted during a 7-year period (2005-2012) in the neonatal intensive care unit of the University Hospital Erasme to assess the value of Gram stain on catheter-drawn blood samples (CDBS) to predict CRBSIs. Both peripheral samples and CDBS were obtained from neonates with clinically suspected CRBSI. Gram stain, automated culture and quantitative cultures on blood agar plates were performed for each sample. The paired quantitative blood culture was used as the standard to define CRBSI. Out of 397 episodes of suspected CRBSIs, 35 were confirmed by a positive ratio of quantitative culture (>5) or a colony count of CDBS culture >100 colony-forming units (CFU)/mL. All but two of the 30 patients who had a CDBS with a positive Gram stain were confirmed as having a CRBSI. Seven patients who had a CDBS with a negative Gram stain were diagnosed as CRBSI. The sensitivity, specificity, positive predictive value and negative predictive value of Gram stain on CDBS were 80, 99.4, 93.3 and 98.1 %, respectively. Gram staining on CDBS is a viable method for rapidly (<1 h) detecting CRBSI without catheter withdrawal.

  3. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  4. Heat treatment effect on the mechanical properties of industrial drawn copper wires

    International Nuclear Information System (INIS)

    Beribeche, Abdellatif; Boumerzoug, Zakaria; Ji, Vincent

    2013-01-01

    In this present investigation, the mechanical properties of industrial drawn copper wires have been studied by tensile tests. The effect of prior heat treatments at 500°C on the drawn wires behavior was the main goal of this investigation. We have found that the mechanical behavior of drawn wires depends strongly on those treatments. SEM observations of the wire cross section after tensile tests have shown that the mechanism of rupture was mainly controlled by the void formation

  5. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  6. Glyco-centric lectin magnetic bead array (LeMBA − proteomics dataset of human serum samples from healthy, Barrett׳s esophagus and esophageal adenocarcinoma individuals

    Directory of Open Access Journals (Sweden)

    Alok K. Shah

    2016-06-01

    Full Text Available This data article describes serum glycoprotein biomarker discovery and qualification datasets generated using lectin magnetic bead array (LeMBA – mass spectrometry techniques, “Serum glycoprotein biomarker discovery and qualification pipeline reveals novel diagnostic biomarker candidates for esophageal adenocarcinoma” [1]. Serum samples collected from healthy, metaplastic Barrett׳s esophagus (BE and esophageal adenocarcinoma (EAC individuals were profiled for glycoprotein subsets via differential lectin binding. The biomarker discovery proteomics dataset consisting of 20 individual lectin pull-downs for 29 serum samples with a spiked-in internal standard chicken ovalbumin protein has been deposited in the PRIDE partner repository of the ProteomeXchange Consortium with the data set identifier PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD002442. Annotated MS/MS spectra for the peptide identifications can be viewed using MS-Viewer (〈http://prospector2.ucsf.edu/prospector/cgi-bin/msform.cgi?form=msviewer〉 using search key “jn7qafftux”. The qualification dataset contained 6-lectin pulldown-coupled multiple reaction monitoring-mass spectrometry (MRM-MS data for 41 protein candidates, from 60 serum samples. This dataset is available as a supplemental files with the original publication [1].

  7. The baseline serum value of α-amylase is a significant predictor of distance running performance.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Tarperi, Cantor; La Torre, Antonio; Guidi, Gian Cesare; Schena, Federico

    2015-02-01

    This study was planned to investigate whether serum α-amylase concentration may be associated with running performance, physiological characteristics and other clinical chemistry analytes in a large sample of recreational athletes undergoing distance running. Forty-three amateur runners successfully concluded a 21.1 km half-marathon at 75%-85% of their maximal oxygen uptake (VO2max). Blood was drawn during warm up and 15 min after conclusion of the run. After correction for body weight change, significant post-run increases were observed for serum values of alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, bilirubin, creatine kinase (CK), iron, lactate dehydrogenase (LDH), triglycerides, urea and uric acid, whereas the values of body weight, glomerular filtration rate, total and low density lipoprotein-cholesterol were significantly decreased. The concentration of serum α-amylase was unchanged. In univariate analysis, significant associations with running performance were found for gender, VO2max, training regimen and pre-run serum values of α-amylase, CK, glucose, high density lipoprotein-cholesterol, LDH, urea and uric acid. In multivariate analysis, only VO2max (p=0.042) and baseline α-amylase (p=0.021) remained significant predictors of running performance. The combination of these two variables predicted 71% of variance in running performance. The baseline concentration of serum α-amylase was positively correlated with variation of serum glucose during the trial (r=0.345; p=0.025) and negatively with capillary blood lactate at the end of the run (r=-0.352; p=0.021). We showed that the baseline serum α-amylase concentration significantly and independently predicts distance running performance in recreational runners.

  8. Clinical usefulness of creatine Kinase BB determination by a Ria method in serum of patients with cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Nuti, A; Giraldi, C; Piccini, P; Bonucelli, U; Clerico, A; Del Chicca, M G

    1988-01-01

    The measurement of creatine kinase BB isoenzyme (CK-BB) using RIA methods could have diagnostic utility as a biological marker of cerebral damage. The aim of the present study is to evaluate whether frequent sampling (4 samples/day for 3 days) permits a better correlation between serum CK/sub B/B values and the clinical outcomes of patients with cerebrovascular accidents. 16 in-patients (12 men and 4 women) with stroke (15 of an ischemic nature and 1 hemorrhagic) have benn studied. The presence of stroke was confirmed by clinical symptoms and by CAT results. Blood samples were drawn at 6 and 12 a.m. and at 6 and 12 p.m. over 3 consecutive days after hospitalization. Values of serum CK-BB above the normal range (>7 ng/ml) were found in the 5 of the 16 (31.3%) patients studied. The mean CK-BB value observed in the patients' group was significantly higher than that found in a group of 112 control subjects (controls, mean+-SD=2.1+-1.7 ng/ml vs patients 3.3+-3.4 ng/ml, unpaired t-test p<0.025). We observed a very wide range of serum CKBB levels in most of the patients studied. Some prominent peaks of CK-BB concetrations were found in patients' outcame (Spearman correlation coefficient r-s=0.618, p<0,01). Although our results indicate that the measurement of CK-BB concentrations cannot be considered a sensitive marker of stroke, the significant correlation between serum CK-BB values and outcome suggests that high CK-BB levels could be a sign of worse prognosis in patients with cerebrovascular accidents. 24 refs.

  9. Clinical usefulness of creatine Kinase BB determination by a Ria method in serum of patients with cerebrovascular accidents

    International Nuclear Information System (INIS)

    Nuti, A.; Giraldi, C.; Piccini, P.; Bonucelli, U.; Clerico, A.; Del Chicca, M. G.

    1988-01-01

    The measurement of creatine kinase BB isoenzyme (CK-BB) using RIA methods could have diagnostic utility as a biological marker of cerebral damage. The aim of the present study is to evaluate whether frequent sampling (4 samples/day for 3 days) permits a better correlation between serum CK B B values and the clinical outcomes of patients with cerebrovascular accidents. 16 in-patients (12 men and 4 women) with stroke (15 of an ischemic nature and 1 hemorrhagic) have benn studied. The presence of stroke was confirmed by clinical symptoms and by CAT results. Blood samples were drawn at 6 and 12 a.m. and at 6 and 12 p.m. over 3 consecutive days after hospitalization. Values of serum CK-BB above the normal range (>7 ng/ml) were found in the 5 of the 16 (31.3%) patients studied. The mean CK-BB value observed in the patients' group was significantly higher than that found in a group of 112 control subjects (controls, mean+-SD=2.1+-1.7 ng/ml vs patients 3.3+-3.4 ng/ml, unpaired t-test p<0.025). We observed a very wide range of serum CKBB levels in most of the patients studied. Some prominent peaks of CK-BB concetrations were found in patients' outcame (Spearman correlation coefficient r-s=0.618, p<0,01). Although our results indicate that the measurement of CK-BB concentrations cannot be considered a sensitive marker of stroke, the significant correlation between serum CK-BB values and outcome suggests that high CK-BB levels could be a sign of worse prognosis in patients with cerebrovascular accidents

  10. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...... in the structure and crystallography when a randomly oriented cementite structure in a patented wire during wire drawing is transformed into a lamellar structure parallel to the drawing axis. Changes in the interlamellar spacing and in the misorientation angle along and across the ferrite lamellae show significant...... through-diameter variations in wires drawn to large strains P 1.5. The structural evolution is hierarchical as the structural variations have their cause in a different macroscopic orientation of the cementite in the initial (patented) structure with respect to the wire axis. The through...

  11. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...... in the structure and crystallography when a randomly oriented cementite structure in a patented wire during wire drawing is transformed into a lamellar structure parallel to the drawing axis. Changes in the interlamellar spacing and in the misorientation angle along and across the ferrite lamellae show significant...... through-diameter variations in wires drawn to large strains ⩾ 1.5. The structural evolution is hierarchical as the structural variations have their cause in a different macroscopic orientation of the cementite in the initial (patented) structure with respect to the wire axis. The through...

  12. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  13. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    Science.gov (United States)

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  14. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  15. Serum prolactin levels in psoriasis and its association with disease activity: A case-control study

    Directory of Open Access Journals (Sweden)

    Mohammad Abid Keen

    2014-01-01

    Full Text Available Background: Psoriasis is a T-cell-mediated autoimmune chronic skin disorder in which an environmental factor, perhaps a viral antigen, induces T cells to produce cytokines. These cytokines stimulate keratinocyte proliferation and production of antigenic adhesion molecules in the dermal blood vessels. Several mediators and hormones have been implicated in keratinocyte hyperproliferation and among these hormones, prolactin (PRL has been found to have an effect on epithelial cells, lymphocytes and keratinocytes, thus an effect on the etiopathogenesis of psoriasis. Aim: The present study was designed to compare serum PRL levels in psoriatic patients with a control group. Settings and Design: This study was a hospital-based case control study, conducted in the department of Dermatology, STD and Leprosy, SMHS Hospital (Associated teaching hospital of Government Medical College Srinagar over a period of 1 year, from September 2012 to 2013. Materials and Methods: The present study included 60 patients of psoriasis (42 males and 18 females and 60 controls matched for age and sex. Serum PRL levels of patients and controls were measured by ECLIA and inferences were drawn. Statistical Analysis Used: Statistical significance of the results was carried out by the Chi-square test and the independent samples t-test. Statistical significance was determined at a level of P < 0.05. Results: Serum PRL levels were significantly increased in patients as compared to the control group (P value: 0.002. There was a positive correlation between pretreatment serum PRL levels and PASI score (r value: 0.379; P value: 0.003. An insignificant association was found between the pretreatment PRL level and serum PRL level after treatment (P value: 0.22. Also, a negative correlation between the duration of psoriasis and serum PRL was seen (r value: -0.008; P value: 0.954. Conclusion: PRL may have a role to play in the etiopathogenesis of psoriasis. However, further studies with

  16. Anti-Taenia solium metacestode IgG antibodies in serum samples from inhabitants of a central-western region of Brazil

    Directory of Open Access Journals (Sweden)

    Oliveira Heliana B. de

    2006-01-01

    Full Text Available A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB. Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51. The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5% and 47-52 kDa (80%. The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001. In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

  17. The use of enzyme-linked immunosorbent assay for detection of Mycoplasma hominis antibodies in infertile women serum samples

    DEFF Research Database (Denmark)

    Baczynska, Agata; Friis Svenstrup, Helle; Fedder, Jens

    2005-01-01

    BACKGROUND: Besides Chlamydiae trachomatis and Mycoplasma genitalium, Mycoplasma hominis may also cause infertility due to damage of the Fallopian tubes. Therefore serum samples from infertile women were analyzed for antibodies to M. hominis. METHODS: Sera from 304 infertile women were investigat...

  18. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  20. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  1. Retrospective analysis of dengue specific IgM reactive serum samples

    Directory of Open Access Journals (Sweden)

    Nemai Bhattacharya

    2013-04-01

    Full Text Available Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1 antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: This reconstructed study revealed that of those 91 dengue cases, 70.3% (64 and 29.7% (27 were suffering from secondary and primary dengue respectively, showing that number of secondary dengue cases were much more than that of primary dengue cases with a possibility of emergence of DHF. A small proportion of cases 18.7% (17 were reactive for NS1. The duration of fever in NS1 antigen positive cases varied between 5 and 7 days. Of 17 NS1 reactive cases, 10 (10.9% and 7 (7.7% were suffering from secondary and primary dengue respectively. Conclusions: Early detection of primary and secondary dengue cases would be facilitated by utilizing all three parameters (NS1 antigen, anti-dengue IgM and IgG helping to evaluate, monitor and treat a dengue case effectively.

  2. Prevalence of parvovirus B19 and parvovirus V9 DNA and antibodies in paired bone marrow and serum samples from healthy individuals.

    Science.gov (United States)

    Heegaard, Erik D; Petersen, Bodil Laub; Heilmann, Carsten J; Hornsleth, Allan

    2002-03-01

    Parvovirus B19 (hereafter referred to as B19) exhibits a marked tropism to human bone marrow (BM), and infection may lead to erythema infectiosum, arthropathy, hydrops fetalis, and various hematologic disorders. Recently, a distinct parvovirus isolate termed V9 with an unknown clinical spectrum was discovered. In contrast to the many studies of B19 serology and viremia, valid information on the frequency of B19 or V9 DNA in the BM of healthy individuals is limited. To develop a reference value, paired BM and serum samples from healthy subjects were tested for the presence of B19 and V9 DNA and specific antibodies. Immunoglobulin M (IgM) was not found in any of the serum samples. The prevalence of IgG showed a gradual and steady increase from 37% in children aged 1 to 5 years to 87% in people aged >50 years. When 190 well-characterized subjects were examined, B19 DNA was detected in the BM of 4 individuals (2.1%; 95% confidence interval, 0.58 to 5.3%) while none of the paired serum samples showed evidence of circulating viral DNA. V9 DNA was not found in any of the BM or serum samples. The finding of B19 DNA probably indicated a primary infection in one 7-year-old individual and reinfection or reactivation of persistent infection in the remaining three persons, aged 47 to 58 years. Serving as a benchmark for future studies, these findings are useful when interpreting epidemiologic data, performing BM transplantation, or considering clinical implications of parvovirus infection.

  3. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  4. Comparison of the Montreal Cognitive Assessment and the Mini-Mental State Examination in detecting multi-domain mild cognitive impairment in a Chinese sub-sample drawn from a population-based study.

    Science.gov (United States)

    Dong, YanHong; Yean Lee, Wah; Hilal, Saima; Saini, Monica; Wong, Tien Yin; Chen, Christopher Li-Hsian; Venketasubramanian, Narayanaswamy; Ikram, Mohammad Kamran

    2013-11-01

    We examined the discriminant validity of the Montreal Cognitive Assessment (MoCA) and the Mini-Mental State Examination (MMSE) in detecting multiple-domain mild cognitive impairment (md-MCI) in a Chinese sub-sample drawn from elderly population-based study. This study included Chinese participants from the Epidemiology of Dementia in Singapore (EDIS) study aged ≥ 60 years who underwent cognitive screening with the Abbreviated Mental Test and Progressive Forgetfulness Questionnaire. Screen-positive participants subsequently underwent MoCA, MMSE, and a comprehensive formal neuropsychological battery. MCI was defined by Petersen's criteria and further classified into single-domain MCI (sd-MCI) and md-MCI. Area under the receiver operating characteristic curve (AUC) with 95% confidence intervals (CIs) was computed for the MoCA and the MMSE in detecting md-MCI. A total of 300 participants were recruited: 128 (42.7%) were diagnosed with no cognitive impairment (NCI), 47 (15.7%) with sd-MCI, and 83 (28.0%) with md-MCI. Forty-one participants were excluded, 7 (2.3%) had dementia, and 34 (11.3%) had only objective cognitive impairment without subjective complaints. Although the MoCA had a significantly larger AUC than the MMSE (0.94 (95% CI = 0.91-0.97) vs. 0.91 (95% CI = 0.86-0.95), p= 0.04), at optimal cut-off points, the MoCA (19/20) was equivalent to the MMSE (25/26) in detecting md-MCI (sensitivity: 0.80 vs. 0.87, specificity: 0.92 vs. 0.80). Both screening tests had good discriminant validity and can be used in detecting md-MCI in a sub-sample of Chinese drawn from a population-based study.

  5. Social Gender in the Pictures Drawn by Students about Physical Education Class

    Science.gov (United States)

    Temel, Cenk; Güllü, Mehmet

    2016-01-01

    The current study aimed to analyze the social gender perception in physical education classes in Turkey through the pictures drawn by students about the physical education class. The document analysis technique, which is a qualitative research method, was used in the study. In the light of this aim, the pictures drawn by a total of 394 students…

  6. Maternal serum theobromine and the development of preeclampsia.

    Science.gov (United States)

    Klebanoff, Mark A; Zhang, Jun; Zhang, Cuilin; Levine, Richard J

    2009-09-01

    Preeclampsia, a disorder with prominent cardiovascular manifestations, is a cause of maternal, fetal, and infant morbidity and mortality. Chocolate contains compounds that may promote cardiovascular health. A recent study found chocolate consumption during pregnancy, and, particularly, increasing cord serum concentration of theobromine (the primary methylxanthine alkaloid in chocolate), to be associated with reduced occurrence of preeclampsia. We studied 2769 women who comprised the control group from a case-control study of caffeine metabolites and spontaneous abortion nested within the Collaborative Perinatal Project. These women were pregnant between 1959 and 1966, with liveborn infants of at least 28 weeks' gestation. Serum was drawn at 26 weeks' gestation, and assayed for theobromine by high-performance liquid chromatography. Odds ratios (ORs) for preeclampsia were estimated using logistic regression, and adjusted for age, education, prepregnant weight, race, parity, smoking, and gestation at blood draw. Preeclampsia occurred in 68 (2.9%) of 2105 eligible women. Adjusted ORs for preeclampsia were near unity across most third-trimester theobromine concentrations. Adjusted ORs for preeclampsia according to theobromine concentration in serum at theobromine and preeclampsia.

  7. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  8. Mass fragmentographic analysis of total cholesterol in serum using a heptadeuterated internal standard

    International Nuclear Information System (INIS)

    Wolthers, B.G.; Hindriks, F.R.; Muskiet, F.A.J.; Groen, A.

    1980-01-01

    A mass fragmentographic method for the determination of total cholesterol in serum using heptadeuterated [25,26,26,26,27,27,27- 2 H] cholesterol as internal standard is presented. The results obtained are compared with a colorimetric and gas chromatographic method which were previously proposed as reference methods. Criteria for the development of absolute measurement by means of mass fragmentography and stable isotopically labelled internal standards are given. The conclusion is drawn that, at present, mass fragmentographic methods for the determination of total cholesterol in serum do not fulfil the criteria required for absolute methods. (Auth.)

  9. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  10. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  11. Hand-Drawn Resistors and a Simple Tester Using a Light-Emitting Diode

    Science.gov (United States)

    Kamata, Masahiro; Abe, Mayumi

    2012-01-01

    A thick line drawn on a sheet of paper with a 6B pencil is electrically conductive and its resistance can be roughly estimated using a simple tester made of a light-emitting diode (LED) and a lithium coin-type cell. Using this hand-drawn resistor and the LED tester, we developed teaching materials that help students to understand how electrical…

  12. Lessons drawn from serious accidents in nuclear power stations

    International Nuclear Information System (INIS)

    Kosciusko-Morizet, F.; Tanguy, P.

    1981-01-01

    Taking a number of serious accidents considered to be particularly representative (Windscale, Enrico Fermi, Lucens, Browns Ferry, Three Mile Island and Saint-Laurent-des-Eaux), the paper analyses the conclusions reached in subsequent enquiries and the lessons drawn from them by the responsible authorities. While design problems sometimes come to light, it is much more generally operational safety - problems related to instructions, the training of operators, the man/machine relationship - which appears to be inadequate. The organization of relations between the different partners - builders, operators and safety bodies - likewise gives rise to some observations. Certain measures should be pursued on a broader scale in order to improve our ability to prevent serious accidents: (i) incidents important from the standpoint of safety must be identified; (ii) these incidents must be brought to the knowledge of all partners concerned, in all interested countries; (iii) the lessons drawn from them must be exchanged and compared; and (iv) the lessons must be made generally available in a directly usable form (i.e. as design modifications, changes in instructions and so on). Particular attention must be given to the problems of countries which are embarking on nuclear programmes and which, with a small number of installations, need direct and permanent access to all the lessons drawn from the operation of a large power station park, and must be able to call upon the assistance of teams from outside in the event of an accident. (author)

  13. Hirarchical structures and strength in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Hansen, Niels; Godfrey, Andrew

    2014-01-01

    and the cementite decomposition, have been analyzed and quantified by scanning electron microscopy, transmission electron microscopy and high resolution electron microscopy for wires cold drawn up to a strain of 3.68. Three strengthening mechanisms, boundary strengthening, dislocation strengthening and solid...... solution hardening, have been analyzed based on the microstructural analysis. The individual and combined contributions, of these mechanisms to the wire strength have been estimated and good agreement has been found between the measured flow stress and values estimated based on an assumption of linear...... additivity of the three strengthening mechanisms. Mechanisms behind the higher strength of about 6.4 GPa in the wires drawn to higher strains and to a finer microstructural scale is also discussed....

  14. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    Science.gov (United States)

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  15. A highly selective and sensitive Tb3+-acetylacetone photo probe for the assessment of acetazolamide in pharmaceutical and serum samples

    Science.gov (United States)

    Youssef, A. O.

    2018-04-01

    A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.

  16. Serum sample levels of bromine, iron, scandium and zinc in preschool children of Atayal and Bunun aborigines living in central Taiwan

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Ding-Bang Lin; Yuan-Yaw Wei

    2006-01-01

    This study determined bromine, iron, scandium and zinc serum levels in Taiwanese aboriginal preschool children living in remote mountainous areas to increase the understanding of the social, cultural, nutrient and ethnic background of the Taiwanese children. Seventy-three serum samples were taken from two ethnic groups of preschool children, Atayal aborigines (AAPC) and Bunun aborigines (BAPC). Sera of these children were freeze dried. Trace elements in sera were identified by instrumental neutron activation analysis (INAA). The accuracy and precision of INAA was evaluated using certified reference materials: Tomato Leaves (NIST-SRM 1570a) and Lichen (IAEA-336). Statistical analysis identified several different patterns for ethnic groups, gender and age via the two-tailed Student's t-test. Analytical results showed that the ranges of Br, Fe, Sc and Zn in sera were somewhat wide. The Zn serum levels (p < 0.05) and Br serum levels (p < 0.01) in the AAPC were significantly lower than those in the BAPC. However, there were no significant differences in Fe or Sc serum levels between the two groups. Analytical results were compared to published data for different counties. This study is the first investigating trace elements in Taiwanese aborigines and can be used to establish a much-needed serum element database. (author)

  17. Wet sample digestion for quantification of vanadium(V) in serum by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Heinemann, G.; Vogt, W.; Jacob, K.

    1999-01-01

    Three types of pressure digestion systems used prior to the determination of the ultratrace element vanadium by electrothermal atomic absorption spectrometry were evaluated: The high-pressure ashing (HPA) system, the DAB III pressure digestion system and the pressurized microwave digestion (PMD) system. Complete sample digestion and no loss of graphite tube sensitivity as well as reliable vanadium values could only be achieved with HPA digests of freeze-dried serum. The mean recovery rate was 98% and no loss of tube sensitivity could be observed. Using non-lyophilized serum the mean recovery rate was 70%. The DAB III digestion system, vicarious for closed pressure digestion in steel bombs with an allowable temperature up to about 200C, cannot be recommended to mineralize human biological material for vanadium determinations, because the remaining not completely decomposed organic compounds extracted together with the vanadium-cupferron complex caused a marked carbon-buildup and formation of carbides in the graphite tube were found to change the shape of the absorption signals distinctly, and to decline the tube sensitivity strongly (about 25%) so that reliable results cannot be achieved. The recovery rate was too low in general (about 50%). In addition, a subsequent treatment of the DAB III digests with perchloric acid was unsuccessful. The PMD system proved to be not suited, because the samples became highly contaminated by vanadium possibly from the titan seal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  18. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  19. Residual stresses evolution in hardening, cold drawn or shot-peening carbon steel as a function of the heating temperature

    International Nuclear Information System (INIS)

    Vannes, A.-B.; Parisot, Alain; Fougeres, Roger; Theolier, Maurice

    1977-01-01

    Residual stress variations are studied in hardening, cold-drawn, shot-peening carbon steel samples as a function of heating temperature or the tempering one. For temperatures between 100 0 C and 250 0 C, a relative maximum is observed for the mean level of the residual stresses. These results are explained on the basis of two antagonistic mechanisms: restoration and ageing [fr

  20. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms.

    Directory of Open Access Journals (Sweden)

    Nick De Regge

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSV is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions.Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively.While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%, the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively. The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively. Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid result indicated the

  1. Structural, magnetic and electrical transport properties in cold-drawn thin Fe-rich wires

    International Nuclear Information System (INIS)

    Garcia, C.; Chizhik, A.; Val, J.J. del; Zhukov, A.; Blanco, J.M.; Gonzalez, J.

    2005-01-01

    Microstructural (X-ray diffraction), magnetic properties (hysteresis loop), electrical resistivity, magneto-impedance and stress impedance effects have been investigated in cold-drawn Fe 77.5 B 15 Si 7.5 amorphous wire. Initial amorphous wire (obtained by the in-rotating-water technique) with diameter of 125 μm was submitted to cold-drawn process decreasing the diameter to 50 μm. Such cold-drawn wire was treated by current annealing (currents of 190, 210, 220 and 230 mA during times between 1 and 45 min) for tailoring the magnetic and electrical transport properties. A qualitative analysis of the magnetoimpedance and stress impedance effects is given by considering the influence of the magnetoelastic anisotropy and frequency of the AC driving electrical current on the circular permeability

  2. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  3. Correlation between serum anyloid a low density lipoprotein and genotoxicity in smokers

    International Nuclear Information System (INIS)

    Jamil, A.; Rashid, A.; Majeed, A.; Naveed, A.K.

    2018-01-01

    Objective:To investigate the relation between serum amyloid A-low density lipoprotein (SAA-LDL) and genotoxicity in smokers. Study Design:An experimental study. Place and Duration of Study:Army Medical College, Rawalpindi and National Institute of Health (NIH), Islamabad, from June 2014 to February 2015. Methodology:Seventy healthy Sprague Dawley rats were purchased from NIH and exposed to cigarette smoke in smoke chamber for three months. Blood samples were drawn from each rat at the end of the study period. SAA-LDL was determined by enzyme-linked immunosorbent assay (ELISA). Genotoxicity was assessed by cytokinesis block micronucleus (CBMN) assay. Pearson correlation was used to find correlation between SAA-LDL and genotoxicity. Results:Strong positive correlation was found between SAA-LDL and micronuclei frequency in smoke-exposed rats (r=0.799, N=70, p <0.01). Conclusion:Statistically significant strong positive correlation between SAA-LDL and genotoxicity in smoke-exposed rats shows that changes in one is associated with changes in other and vice versa. (author)

  4. A Novel Genetic Group of Bovine Hepacivirus in Archival Serum Samples from Brazilian Cattle

    Directory of Open Access Journals (Sweden)

    Cláudio W. Canal

    2017-01-01

    Full Text Available Hepatitis C virus (HCV (genus Hepacivirus; family Flaviviridae is a major human pathogen causing persistent infection and hepatic injury. Recently, emerging HCV-like viruses were described infecting wild animals, such as bats and rodents, and domestic animals, including dogs, horses, and cattle. Using degenerate primers for detecting bovine pestiviruses in a 1996 survey three bovine serum samples showed a low identity with the genus Pestivirus of the Flaviviridae family. A virus could not be isolated in cell culture. The description of bovine hepaciviruses (BovHepV in 2015 allowed us to retrospectively identify the sequences as BovHepV, with a 88.9% nucleotide identity. In a reconstructed phylogenetic tree, the Brazilian BovHepV samples grouped within the bovine HCV-like cluster in a separated terminal node that was more closely related to the putative bovine Hepacivirus common ancestor than to bovine hepaciviruses detected in Europe and Africa.

  5. The Correlation between Troponin and Ferritin Serum Levels in the Patients with Major Beta-Thalassemia

    Directory of Open Access Journals (Sweden)

    Iraj Shahramian

    2013-06-01

    Full Text Available Background: Thalassemia is a hereditary hemoglobinopathy whose most common complication is cardiac involvement which ends up in these patients’ death. Since troponin is a sensitive and specific marker for the detection of microinfarct, we studied the relationship between troponin and ferritin serum levels for early diagnosis of cardiac involvement in these patients. Materials and Methods: This case-control study was performed on 80 patients, including 40 patients with major thalassemia and normal echocardiography and 40 healthy volunteers ranging from 6 months to 16 years old. All the children were examined and the eligible children who were not infected with known heart disease, iron deficiency anemia, kidney disease, diabetes, fever, and systemic diseases were enrolled into the study after obtaining written informed consents from their parents. At 8:00 A.M. before breakfast, 5cc blood was drawn from these children. After collecting the samples, ferritin and troponin serum levels were evaluated using ELISA and electro- kymonolonsense methods, respectively. The gathered data were analyzed through the SPSS statistical software (v. 20 and T-test. Besides, P value<0.05 was considered as statistically significant. Results: The study results revealed a significant difference between the two groups regarding the mean of the serum levels of troponin (P=0.045 and ferritin (P=0.001. In this study, no significant correlation was observed between serum troponin and ferritin levels and age and BMI in the two groups. Also, no significant relationship was found between serum troponin level and sex (P=0.264. Conclusions: In microinfarct, troponin increases independent of ferritin; therefore, it can be used for early detection of cardiac involvement in thalassemia patients to determine the sub-clinical effects.

  6. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  7. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    -13, and VEGF, LH plasma levels vs. EDTA plasma: IL-2 and IL-4. CONCLUSION: Stored serum, LH plasma, and EDTA plasma from clinical trials can be used for analysis of circulating cytokines and proteins. Variations in measurements occur, but are within reasonable ranges. The optimal type of media...... in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...... on different dates was reasonable. However, samples run on different dates could exhibit different absolute values. The 75th percentile of the fold differences for samples run on different dates was 2.2. No significant difference was found between one and four freeze-thaw cycles (except for HGF...

  8. Detection of cryoglobulins in serum of Caspian miniature horse

    Directory of Open Access Journals (Sweden)

    Atyabi, N,

    2012-06-01

    Full Text Available Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was performed on normal serum samples and also on four serum samples containing precipitates using an automated electrophoresis system on cellulose acetate strips. In addition Ig isotypes detection (IgG, IgM and IgA was performed on both precipitates and serum containing precipitates using single radio immunediffusion method (SRID. A narrow-based peak on gamma region of precipitate acetate cellulose strips was observed. Precipitate concentrations were strikingly higher than normal concentration of serum immuneglobulins. It can be suggested that cryoglobulin concentration in a proportion of Caspian miniature horse is higher than other equides may be in relation with animal susceptibility to neoplasias such as lymphoma and leukemia.

  9. Radioimmunologic determination of alphafetoproteins concentration in blood serum samples and in the amniotic fluid in healthy pregnant women in the 2 trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Skalba, P; Krupa, B; Rozmus, M; Brudnik, K; Kokocinska, D; Rajs, M [Slaska Akademia Medyczna, Katowice (Poland)

    1980-01-01

    Radioimmunologic technique of double antibodies was used for the determination of alphafetoprotein (AFP) concentrations in blood serum samples from 223 healthy, pregnant women with single pregnancies and in amniotic fluid samples from 43 donors. The gestational age during samples collection was 10 to 25 weeks. The AFP preparation for the test was supplied by the International Agency of Cancer Research, anti-AFP antibodies produced by Behringwerke and personally produced rabbit antiglobulin antibodies. The results of the AFP determinations in the blood and amniotic fluid samples were presented in tables in form of medians. The serum AFP concentrations overranging the double medians value were met in 8.5%, overranging the triple medians - in 2.6%. Repeat determinations decreased the number of false positive results for about 50%. The results permit to issue a conclusion that the used technique is fully applicable for scan examinations in prenatal diagnosis of fetal nervous system malformations.

  10. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  11. Association of dyslipidemia, increased insulin resistance, and serum CA 15-3 with increased risk of breast cancer in urban areas of North and Central India

    Directory of Open Access Journals (Sweden)

    Poonam Kachhawa

    2018-01-01

    Full Text Available Objective: This study aims to determine the association of dyslipidemia and increased insulin resistance (IR with increased breast cancer (BC risk. Materials and Methods: The study group comprised 110 premenopausal and 143 postmenopausal, untreated female BC patients in the age range of 29–72 years. Control group consisted of 117 premenopausal and 141 postmenopausal healthy females in the age range of 23–75. Approximately 8-ml blood samples were drawn to measure various biochemical parameters. Serum glucose, total cholesterol, triglyceride (TG, and high-density lipoprotein-cholesterol were measured. Very low-density lipoprotein-cholesterol (VLDL-C and LDL-C were calculated using Friedewald's formula. Serum insulin and serum CA 15-3 were estimated by immune enzymatic assay. IR was assessed using homeostasis model assessment IR index (HOMA-IR. Results: Clinical variables in the case and control groups were compared using the unpaired Student's t-test. The crude and adjusted odds ratios (ORs and 95% confidence intervals (CIs were calculated by binary logistic regression analysis. Pearson's correlation analysis was used to determine the association between CA 15-3 and variables of interest. Total cholesterol, TG, LDL, VLDL, serum glucose, serum insulin, HOMA-IR, and serum CA 15-3 were significantly higher (P < 0.001 in BC patients compared to those in controls. Significant adjusted ORs with 95% CI were found to be fasting glucose, total cholesterol, and TGs. We also found a significant positive correlation between total cholesterol, TG, LDL, serum glucose, serum insulin, HOMA-IR, and serum CA 15-3. Conclusion: This study confirms the association between dyslipidemia, IR, and increased BC risk.

  12. Origin of DNA in human serum and usefulness of serum as a material for DNA typing.

    Science.gov (United States)

    Takayama, T; Yamada, S; Watanabe, Y; Hirata, K; Nagai, A; Nakamura, I; Bunai, Y; Ohya, I

    2001-06-01

    The aims of this study were to clarify the origin of DNA in human serum and to investigate whether serum is a material available for DNA typing in routine forensic practice. Blood was donated from 10 healthy adult volunteers and stored for up to 8 days, at 4 degrees C and at room temperature. The serum DNA concentration at zero time was in the range of 5.6 to 21.8 ng/ml with a mean of 12.2+/-1.6 ng/ml. The concentrations increased with storage time. On agarose gel electrophoresis, all serum samples showed ladder patterns and the size of each band was an integer multiple of approximately 180 bp considered to be characteristic of apoptosis. DNA typing from DNA released by apoptosis was possible. Exact DNA typing of D1S80, HLA DQA1, PM, CSF1PO, TPOX, TH01 and vWA was possible for each sample. These results indicate that serum contains fragmented DNA derived from apoptosis of leukocytes, especially neutrophils, and that fragmented DNA is an appropriate material for DNA typing.

  13. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  14. SERUM LEVEL OF LIPIDS, APOLIPOPROTEINS AND VITAMIN D IN CHILDREN AT HIGH RISK OF CORONARY ARTERY DISEASE

    Directory of Open Access Journals (Sweden)

    M BASHTAM

    2002-06-01

    Full Text Available Introduction. Coronary artery disease (CAD is one of the most prevalent disease in human population that has high prevalence and mortality in lsfahan (Iran. As positive family history and changes in serum lipids and lipoproteins are risk factors of these diseases, and also studies have showed the relationship between serum vitamin D and CAD, we studied serum level of lipids, lipoproteins and vitamin D in high risk children compared with control group, and the relation between serum vitamin D and other factors. Methods. This case-control study was done on 44 subjects (25 boys, 19 girls aged 2-18 years old with positive CAD family history as case group and also 44 persons with negative CAD family history as control group with the same age groups. The subjects were selected by convenience sampling method. Children who consumed antiepilepthic drugs as phenytoin or phenobarbital and those who had positive family histroy for renal stone were excluded for variable vitamin D levels due to drug interaction and genetic susceptibility, respectively. All subjects were invited to Isfahan Cardiovascular Research Center. Using a questionnaire, information on personal characteristics, CVD family history and ... were obtained. A fasting (12-14 hr blood sample was drawn from each one. Serum APOA1, APO B100 and vitamin Dwere measured by radioimmunoassay and serum lipids by ELAN 2000 autoanalyzer. Statistical analysis was done by SPSS. The level of serum APOA1, APO B100 and vitamin D were compared between two groups by independent t test and the relation of the mentioned apolipoproteins with vitamin D was studied using multiple linear regression. Results. Serum vitamin D was significantly lower in case group (P < 0.045. Among studied factors, only triglyceride was significantly higher in control group (P < 0.0001 and also no significant relaitonship was observed between serum APO A1, APO B100 and vitamin D. Sex comparision in case group showed those mean levels

  15. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  16. Prevalence of serum anti-neuronal autoantibodies in patients admitted to acute psychiatric care

    DEFF Research Database (Denmark)

    Schou, M; Sæther, S G; Borowski, K

    2016-01-01

    BACKGROUND: Autoimmune encephalitis associated with anti-neuronal antibodies may be challenging to distinguish from primary psychiatric disorders. The significance of anti-neuronal antibodies in psychiatric patients without clear evidence of autoimmune encephalitis is unknown. We investigated...... the serum prevalence of six anti-neuronal autoantibodies in a cohort of unselected patients admitted to acute psychiatric care. METHOD: Serum was drawn from 925 patients admitted to acute psychiatric in-patient care. Psychiatric diagnoses were set according to International Classification of Diseases (ICD......)-10 criteria. Antibody analysis was performed with an indirect immunofluorescence test for N-methyl d-aspartate receptor (NMDAR) antibodies and five other anti-neuronal autoantibodies of the immunoglobulin (Ig) classes IgA, IgG and IgM isotype. RESULTS: Anti-neuronal autoantibodies were found in 11...

  17. Identification of serum metabolites associated with risk of type 2 diabetes using a targeted metabolomic approach.

    Science.gov (United States)

    Floegel, Anna; Stefan, Norbert; Yu, Zhonghao; Mühlenbruch, Kristin; Drogan, Dagmar; Joost, Hans-Georg; Fritsche, Andreas; Häring, Hans-Ulrich; Hrabě de Angelis, Martin; Peters, Annette; Roden, Michael; Prehn, Cornelia; Wang-Sattler, Rui; Illig, Thomas; Schulze, Matthias B; Adamski, Jerzy; Boeing, Heiner; Pischon, Tobias

    2013-02-01

    Metabolomic discovery of biomarkers of type 2 diabetes (T2D) risk may reveal etiological pathways and help to identify individuals at risk for disease. We prospectively investigated the association between serum metabolites measured by targeted metabolomics and risk of T2D in the European Prospective Investigation into Cancer and Nutrition (EPIC)-Potsdam (27,548 adults) among all incident cases of T2D (n = 800, mean follow-up 7 years) and a randomly drawn subcohort (n = 2,282). Flow injection analysis tandem mass spectrometry was used to quantify 163 metabolites, including acylcarnitines, amino acids, hexose, and phospholipids, in baseline serum samples. Serum hexose; phenylalanine; and diacyl-phosphatidylcholines C32:1, C36:1, C38:3, and C40:5 were independently associated with increased risk of T2D and serum glycine; sphingomyelin C16:1; acyl-alkyl-phosphatidylcholines C34:3, C40:6, C42:5, C44:4, and C44:5; and lysophosphatidylcholine C18:2 with decreased risk. Variance of the metabolites was largely explained by two metabolite factors with opposing risk associations (factor 1 relative risk in extreme quintiles 0.31 [95% CI 0.21-0.44], factor 2 3.82 [2.64-5.52]). The metabolites significantly improved T2D prediction compared with established risk factors. They were further linked to insulin sensitivity and secretion in the Tübingen Family study and were partly replicated in the independent KORA (Cooperative Health Research in the Region of Augsburg) cohort. The data indicate that metabolic alterations, including sugar metabolites, amino acids, and choline-containing phospholipids, are associated early on with a higher risk of T2D.

  18. Serum copper and zinc concentrations in a representative sample of the Canarian population.

    Science.gov (United States)

    Díaz Romero, Carlos; Henríquez Sánchez, Patricia; López Blanco, Félix; Rodríguez Rodríguez, Elena; Serra Majem, Lluis

    2002-01-01

    Serum copper (Cu) and zinc (Zn) concentrations of 395 individuals (187 males + 208 females) living in Canary Islands were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 1.10 +/- 0.25 mg/L and 1.16 +/- 0.52 mg/L respectively. Our data were similar to other data published in other Spanish regions. Individuals from Lanzarote presented a mean Cu and Zn concentrations higher (p EL Hierro showed the lowest (p 0.05) among the different age intervals. No clear trends in the serum Cu and Zn concentrations were observed when drinking and smoking habits were considered. The increase of physical exercise reduced (p < 0.05) the serum Cu concentrations.

  19. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    International Nuclear Information System (INIS)

    Fliniaux, Ophélie; Gaillard, Gwenaelle; Lion, Antoine; Cailleu, Dominique; Mesnard, François; Betsou, Fotini

    2011-01-01

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4°C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4°C. Five or ten serum freeze–thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  20. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  1. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  2. Serum cytokine levels in Kleine-Levin syndrome

    DEFF Research Database (Denmark)

    Kornum, Birgitte Rahbek; Rico, Thomas; Lin, Ling

    2015-01-01

    in USA, France, and Taiwan in a clinical setting. Processing of the samples was performed at the Stanford Center for Sleep Sciences and Medicine. RESULTS: We did not observe any changes in serum cytokine levels during KLS episodes compared to between episodes. In a small cohort of asymptomatic KLS...... patients and age- and gender matched healthy controls (n = 8/group) whose blood samples were all collected and processed at the same day; asymptomatic KLS patients had significantly higher levels of serum sVCAM1 cytokine compared to healthy controls. CONCLUSION: These data suggest that KLS episodes...... unknown. The objective of this study was to determine serum cytokine levels in patients with KLS during and between episodes. PATIENTS/METHODS: Fifty-two typical KLS patients were included in the study of whom 17 patients donated blood samples both during and between episodes. Blood samples were collected...

  3. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  4. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Fliniaux, Ophelie [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Gaillard, Gwenaelle [Biobanque de Picardie (France); Lion, Antoine [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Cailleu, Dominique [Batiment Serres-Transfert, rue de Mai/rue Dallery, Plateforme Analytique (France); Mesnard, Francois, E-mail: francois.mesnard@u-picardie.fr [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Betsou, Fotini [Integrated Biobank of Luxembourg (Luxembourg)

    2011-12-15

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4 Degree-Sign C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4 Degree-Sign C. Five or ten serum freeze-thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  5. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  6. The relationship between metabolic presbycusis and serum paraoxonase/arylesterase activity.

    Science.gov (United States)

    Keleş, Erol; Kapusuz, Zeliha; Gürsu, Mehmet Ferit; Karlıdag, Turgut; Kaygusuz, Irfan; Bulmuş, Funda Gülcü; Yalcın, Sinasi

    2014-01-01

    To determine the presence of a relationship between metabolic presbycusis and serum paraoxonase/arylesterase activity. A total of 30 patients who had been admitted to the Ear, Nose, and Throat (ENT) Clinic of Fırat University Medical Faculty and diagnosed as metabolic presbycusis were included in the study. The control group was composed of 30 healthy volunteers. Pure tone audiometry and impedencemeter were performed on all subjects included in the study at the audiometry laboratory of the ENT clinic. The presence of a regular hearing curve, a symmetrical sensorineural hearing loss more than 25 dB with preserved speech discrimination were accepted as criteria for metabolic presbycusis. Blood samples were drawn from the patients prior to the hearing tests. The sera were separated for measurements of total cholesterol, triglyceride, high-density lipoprotein, very low-density lipoprotein, low-density lipoprotein, human serum paraoxonase and arylesterase levels, respectively. No statistically significant difference was found between the patient and the control groups in terms of age and gender. Paraoxonase, arylesterase and paraoxonase/arylesterase, high-density lipoprotein levels were found to decrease in the study group and the difference was found to be statistically significant compared to the control group (P presbycusis. Furthermore, the results of this study make us think that there could be a relationship between metabolic presbycusis and cardiovascular diseases. In this case, metabolic presbycusis may be a determining parameter in the early diagnosis of cardiovascular diseases. We consider that this study may be the pioneer for further studies conducted with larger patient numbers.

  7. Systematic sampling of discrete and continuous populations: sample selection and the choice of estimator

    Science.gov (United States)

    Harry T. Valentine; David L. R. Affleck; Timothy G. Gregoire

    2009-01-01

    Systematic sampling is easy, efficient, and widely used, though it is not generally recognized that a systematic sample may be drawn from the population of interest with or without restrictions on randomization. The restrictions or the lack of them determine which estimators are unbiased, when using the sampling design as the basis for inference. We describe the...

  8. The effect of elevated die temperature on deformation of deep drawn round metal cup

    Science.gov (United States)

    Basril, M. A. M.; Hafsyam, Y. M.; Azuddin, M.; Choudhury, I. A.

    2017-06-01

    One of the major considerations in the current deep drawing practice is the product quality. In this research, the effect of heating temperature on the drawability of the round metal cup has been investigated. Firstly, round metal cups of aluminium and mild steel were drawn from the blank diameters of 60 mm, 65 mm and 70 mm. The experiment conducted at room temperature first, then at 50°C and 100°C. The elongation of the major and minor strains along the cup profile after the process is measured and analysed. On the other hand, the defects from the experiment output and ABAQUS/CAE simulation are compared. The result from experiment shows that the highest major elongation is 11.64 mm and it is happened to a deep drawn aluminium round cup with LDR of 1.69 at temperature of 100°C. On the other hand, for deep drawn mild steel round cup, shows highest major elongation of 12.44 mm for a cup with LDR of 1.56 at 100°C. Both of these statements indicates that the higher temperature could improve the formability of the deep drawn parts besides reducing the probability of the defect to be happened.

  9. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  10. 7 CFR 51.17 - Official sampling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Official sampling. 51.17 Section 51.17 Agriculture... Inspection Service § 51.17 Official sampling. Samples may be officially drawn by any duly authorized... time and place of the sampling and the brands or other identifying marks of the containers from which...

  11. Paper-based potentiometric pH sensor using carbon electrode drawn by pencil

    Science.gov (United States)

    Kawahara, Ryotaro; Sahatiya, Parikshit; Badhulika, Sushmee; Uno, Shigeyasu

    2018-04-01

    A flexible and disposable paper-based pH sensor fabricated with a pencil-drawn working electrode and a Ag/AgCl paste reference electrode is demonstrated for the first time to show pH response by the potentiometric principle. The sensor substrate is made of chromatography paper with a wax-printed hydrophobic area, and various types of carbon pencils are tested as working electrodes. The pH sensitivities of the electrodes drawn by carbon pencils with different hardnesses range from 16.5 to 26.9 mV/pH. The proposed sensor is expected to be more robust against shape change in electrodes on a flexible substrate than other types of chemiresistive/amperometric pH sensors.

  12. Structural Analysis of Hand Drawn Bumblebee Bombus terrestris Silk

    Directory of Open Access Journals (Sweden)

    Andrea L. Woodhead

    2016-07-01

    Full Text Available Bombus terrestris, commonly known as the buff-tailed bumblebee, is native to Europe, parts of Africa and Asia. It is commercially bred for use as a pollinator of greenhouse crops. Larvae pupate within a silken cocoon that they construct from proteins produced in modified salivary glands. The amino acid composition and protein structure of hand drawn B. terrestris, silk fibres was investigated through the use of micro-Raman spectroscopy. Spectra were obtained from single fibres drawn from the larvae salivary gland at a rate of 0.14 cm/s. Raman spectroscopy enabled the identification of poly(alanine, poly(alanine-glycine, phenylalanine, tryptophan, and methionine, which is consistent with the results of amino acid analysis. The dominant protein conformation was found to be coiled coil (73% while the β-sheet content of 10% is, as expected, lower than those reported for hornets and ants. Polarized Raman spectra revealed that the coiled coils were highly aligned along the fibre axis while the β-sheet and random coil components had their peptide carbonyl groups roughly perpendicular to the fibre axis. The protein orientation distribution is compared to those of other natural and recombinant silks. A structural model for the B. terrestris silk fibre is proposed based on these results.

  13. Quantitative determination of albumin in microlitre amounts of rat serum: With a short note on serum albumin levels in ageing rats

    NARCIS (Netherlands)

    Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.; Hollander, C.F.

    1967-01-01

    A simple dye binding method for determining rat serum albumin, which employs the anionic dye 2-(4′-hydroxybenzneeazo) benzoic acid (HBABA) is described. Albumin in 5μ1 of serum is determined colorimetrically. Purified rat albumin is used as a primary standard and rat serum as a reference sample.

  14. Quantitating Iron in Serum Ferritin by Use of ICP-MS

    Science.gov (United States)

    Smith, Scott M.; Gillman, Patricia L.

    2003-01-01

    A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid

  15. X-ray residual stress measurements on cold-drawn steel wire

    NARCIS (Netherlands)

    Willemse, P.F.; Naughton, B.P.; Verbraak, C.A.

    1982-01-01

    The interplanar spacing d{hkl} versus sin2 ψ distributions were measured for the 211, 310, 220 and 200 reflections from severely cold-drawn 0.7% C steel wire with a diameter of 0.25 mm. From the shape of the curves it was concluded that, as well as a 110 fibre texture and elastic anisotropy, plastic

  16. Serum IgG antibody levels to periodontal microbiota are associated with incident Alzheimer disease.

    Science.gov (United States)

    Noble, James M; Scarmeas, Nikolaos; Celenti, Romanita S; Elkind, Mitchell S V; Wright, Clinton B; Schupf, Nicole; Papapanou, Panos N

    2014-01-01

    Periodontitis and Alzheimer disease (AD) are associated with systemic inflammation. This research studied serum IgG to periodontal microbiota as possible predictors of incident AD. Using a case-cohort study design, 219 subjects (110 incident AD cases and 109 controls without incident cognitive impairment at last follow-up), matched on race-ethnicity, were drawn from the Washington Heights-Inwood Columbia Aging Project (WHICAP), a cohort of longitudinally followed northern Manhattan residents aged >65 years. Mean follow-up was five years (SD 2.6). In baseline sera, serum IgG levels were determined for bacteria known to be positively or negatively associated with periodontitis (Porphyromonas gingivalis, Tannerella forsythia, Actinobacillus actinomycetemcomitans Y4, Treponema denticola, Campylobacter rectus, Eubacterium nodatum, and Actinomyces naeslundii genospecies-2). In all analyses, we used antibody threshold levels shown to correlate with presence of moderate-severe periodontitis. Mean age was 72 years (SD 6.9) for controls, and 79 years (SD 4.6) for cases (pthe sample. In a model adjusting for baseline age, sex, education, diabetes mellitus, hypertension, smoking, prior history of stroke, and apolipoprotein E genotype, high anti-A. naeslundii titer (>640 ng/ml, present in 10% of subjects) was associated with increased risk of AD (HR = 2.0, 95%CI: 1.1-3.8). This association was stronger after adjusting for other significant titers (HR = 3.1, 95%CI: 1.5-6.4). In this model, high anti-E. nodatum IgG (>1755 ng/ml; 19% of subjects) was associated with lower risk of AD (HR = 0.5, 95%CI: 0.2-0.9). Serum IgG levels to common periodontal microbiota are associated with risk for developing incident AD.

  17. Quantitative proteomic analysis for high-throughput screening of differential glycoproteins in hepatocellular carcinoma serum

    International Nuclear Information System (INIS)

    Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing

    2015-01-01

    Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC

  18. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    Science.gov (United States)

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  20. The effect of mechano-chemical treatment on structural properties of the drawn TiNi-based alloy wire

    Science.gov (United States)

    Anikeev, Sergey; Hodorenko, Valentina; Gunther, Victor; Chekalkin, Timofey; Kang, Ji-hoon; Kang, Seung-baik

    2018-01-01

    The rapid development of biomedical materials with the advanced functional characteristics is a challenging task because of the growing demands for better material properties in-clinically employed. Modern medical devices that can be implanted into humans have evolved steadily by replacing TiNi-based alloys for titanium and stainless steel. In this study, the effect of the mechano-chemical treatment on structural properties of the matrix and surface layer of the drawn TiNi-based alloy wire was assessed. A range of samples have been prepared using different drawing and etching procedures. It is clear from the results obtained that the fabricated samples show a composite structure comprising the complex matrix and textured oxycarbonitride spitted surface layer. The suggested method of surface treatment is a concept to increase the surface roughness for the enhanced bio-performance and better in vivo integration.

  1. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  2. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  3. Ochratoxin A in serum of swine from different Brazilian states.

    Science.gov (United States)

    Krüger, César D; Cavaglieri, Lilia R; Direito, Glória M; Keller, Kelly M; Dalcero, Ana M; da Rocha Rosa, Carlos A

    2010-09-01

    The aims of the current study were to monitor the presence of ochratoxin A (OTA) in the serum of slaughtered swine and to investigate its distribution in 4 major geographical regions of Brazil. A total of 400 samples of serum were collected from 4 major states of Brazil (100 samples each). Ochratoxin A concentrations were determined by high-performance liquid chromatography. In Santa Catarina State, 60% of the samples had OTA concentrations ranging from 4.01 to 75.4 mg/l. In Mato Grosso State, 75% of the samples had OTA concentrations ranging from 0.17 to 46.79 mg/l. Bahia State samples had OTA concentrations ranging from 2.72 to 4.13 mg/l in 36% of the samples, whereas 68% of the samples from Rio de Janeiro State had OTA concentrations ranging from 0.16 to 115 mg/l. Only Santa Catarina State and Rio de Janeiro State had serum samples that exceeded 75 mg/l OTA in 20% and 2% of the samples, respectively. A direct relationship between the higher concentrations of OTA in serum from the States of Santa Catarina and Rio de Janeiro and the highest concentrations of OTA in food intended for animal consumption in the same 2 Brazilian states was found in the present study. Ochratoxin A distribution in foodstuffs is very heterogeneous, and an alternative method by which to monitor the presence of OTA in feed includes analyzing swine serum samples, which reflect the toxin content of the ingested feed. This strategy could prevent the occurrence of ochratoxicosis in animal production, reduce economic losses, and minimize hazards to human health.

  4. Influence of feeding on serum canine pancreatic lipase immunoreactivity concentrations

    Directory of Open Access Journals (Sweden)

    Steiner JM

    2014-10-01

    Full Text Available Jörg M Steiner, Craig G Ruaux, David A Williams Gastrointestinal Laboratory, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA Abstract: Measurement of serum concentration of pancreatic lipase immunoreactivity (PLI has been shown to be highly specific for exocrine pancreatic function and sensitive for the diagnosis of canine pancreatitis. Currently, it is recommended that food be withheld for at least 12 hours before collecting a blood sample for analysis from dogs. However, it is unknown whether feeding has any influence on serum canine PLI concentration. Thus, the goal of this study was to evaluate the influence of feeding on serum canine PLI concentrations in healthy dogs. Food was withheld from eight healthy adult Beagle dogs for at least 17 hours and a baseline serum sample (0 minutes was collected. Dogs were fed and serum samples were collected at 15, 30, 45, 60, 75, 90, 105, 150, 180, 210, 240, 300, 360, 420, and 480 minutes. There was no significant difference in serum canine PLI concentrations at any time after feeding (P=0.131. We conclude that feeding has no significant influence on serum canine PLI concentrations. Keywords: dog, pancreatic function, pancreatitis, biomarker, diagnostic test

  5. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  6. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  7. LEVELS OF NEUROSPECIFIC ENOLASE AND ENOLASE-SPECIFIC AUTOANTIBODIES IN BLOOD SERUM OF THE PATIENTS WITH AUTOIMMUNE THYROPATIES

    Directory of Open Access Journals (Sweden)

    N. N. Tsybikov

    2010-01-01

    Full Text Available The patients with autoimmune thyroiditis and various functional states of thyroid gland, and diffuse toxic goiter with pronounced thyrotoxicosis were studied for neurospecific enolase and enolase-specific autoantibodies levels in blood serum. Increased concentrations of neurospecific enolase and specific autoantibodies were revealed in all groups of the patients. A conclusion was drawn that nervous system may be involved into pathological process during development of thyropaties.

  8. Serum Lipid Profile: Fasting or Non-fasting?

    OpenAIRE

    Nigam, P. K.

    2010-01-01

    Serum lipid profile has now become almost a routine test. It is usually done in fasting state due to certain limitations in non-fasting serum sample. In the recent past efforts have been made to simplify blood sampling by replacing fasting lipid profile with non-fasting lipid profile. However, fasting specimen is preferred if cardiovascular risk assessment is based on total cholesterol, LDL cholesterol or non-HDL cholesterol. A lot has yet to be done in this area. Till then we have to believe...

  9. Evaluation of a type 1 diabetes serum cohort by SELDI-TOF MS protein profiling

    DEFF Research Database (Denmark)

    Albrethsen, J.; Kaas, A.; Schonle, E.

    2009-01-01

    Proteomics analysis of serum from patients with type 1 diabetes (T1D) may lead to novel biomarkers for prediction of disease and for patient monitoring. However, the serum proteome is highly sensitive to sample processing and before proteomics biomarker research serum cohorts should preferably...... be examined for potential bias between sample groups. S ELDI-TOF MS protein profiling was used for preliminary evaluation of a biological-bank with 766 serum samples from 270 patients with T1D, collected at 18 different paediatric centers representing 15 countries in Europe and Japan over 2 years (2000......-2002). Samples collected 1 (n = 270), 6 (n = 248), and 12 (n = 248) months after T1D diagnosis were grouped across centers and compared. The serum protein profiles varied with collection site and day of analysis; however, markers of sample processing were not systematically different between samples collected...

  10. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  11. Revealing microstructural and mechanical characteristics of cold-drawn pearlitic steel wires undergoing simulated galvanization treatment

    Energy Technology Data Exchange (ETDEWEB)

    Fang Feng, E-mail: fangfeng@seu.edu.cn [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Hu Xianjun [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Jiangsu Sha-Steel Group, Zhangjiagang City, Jiangsu Province 215625 (China); Chen Shaohui [Jiangsu Sha-Steel Group, Zhangjiagang City, Jiangsu Province 215625 (China); Xie Zonghan [School of Engineering, Edith Cowen University, Joondalup, WA 6027 (Australia); Jiang Jianqing [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China)

    2012-06-15

    Highlights: Black-Right-Pointing-Pointer Annealing time on microstructure and mechanical properties of cold-drawn steel wires were studied. Black-Right-Pointing-Pointer Exothermic peak in cold-drawn wire was resulting from the spheroidization of lamellar cementite. Black-Right-Pointing-Pointer Spheroidization of lamellar cementite is the main effect for torsion property of wires after annealing. - Abstract: Spheroidization of lamellar cementite often occurs in cold-drawn pearlitic steel wires during galvanizing treatment, leading to the degradation of mechanical properties. Therefore, it is important to understand effects of galvanization process on microstructure and mechanical properties of cold-drawn wires. In this paper, cold-drawn steel wires were fabricated by cold drawing pearlitic steel rods from 13 mm to 6.9 mm in diameter. Thermal annealing at 450 Degree-Sign C was used to simulate galvanizing treatment of steel wires. Tensile strength, elongation and torsion laps of steel rods and wires with, and without, annealing treatment were determined. Microstructure was observed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In addition, differential scanning calorimetry (DSC) was used to probe the spheroidization temperature of cementite. Experimental results showed that tensile strength of wires increased from 1780 MPa to 1940 MPa for annealing <5 min, and then decreased. Tensile strength became constant for annealing >10 min. Elongation of wires decreased for annealing <2.5 min, and then recovered slightly. It approached a constant value for annealing >5 min. Tensile strength and elongation of wires were both influenced by the strain age hardening and static recovery processes. Notably, torsion laps of wires hardly changed when annealing time was less than 2.5 min, and then decreased rapidly. Its value became constant when the hold time is greater than 10 min. Lamellar cementite began to spheroidize at annealing >2.5 min

  12. Levels of some trace elements in serum of esophageal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, D M. A. [Sudan Academy of Sciences, Atomic Energy Council, Khartoum (Sudan)

    2011-01-15

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  13. Levels of some trace elements in serum of esophageal cancer patients

    International Nuclear Information System (INIS)

    Saeed, D. M. A.

    2011-01-01

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  14. Clinical implications in the prevalence and associated cardiovascular factors of elevated serum alanine aminotransferase levels among elderly agricultural and fishing population in Taipei, Taiwan: experience at a teaching hospital.

    Science.gov (United States)

    Chen, Yu-Fen; Hu, Yi-Chun; Shen, Hsi-Che; Chang, Hui-Te; Tung, Tao-Hsin

    2014-01-01

    To discuss the prevalence and associated factors related to an elevated serum alanine aminotransferase (ALT) level among the elderly agricultural and fishing population. A total of 6542 (3989 males and 2553 females) healthy adults voluntarily admitted to a teaching hospital for a physical checkup in 2010 in Taipei, Taiwan. Fasting blood samples were drawn via venipuncture, and clinical nurses interviewed the study participants using a structured questionnaire from. The overall prevalence of an elevated serum ALT level was 18.2% and revealed a statistically significant decrease with increasing age (P < 0.001). The men exhibited a higher prevalence than the women (19.7% vs 15.9%; P < 0.001). Male sex; younger age; and presence of obesity, hypertension, hyperuricemia, and hypoalbuminemia were significantly associated with an elevated serum ALT level. Sex-related differences were also revealed. For the men, type 2 diabetes (odds ratio [OR], 1.23; 95% confidence interval [CI], 1.02-1.57), hypercholesterolemia (OR, 1.78; 95% CI, 1.22-2.83), hypertriglyceridemia (OR, 1.32; 95% CI, 1.04-1.73), and low high-density lipoprotein (OR, 1.26; 95% CI, 1.05-1.51) were significantly related to an elevated serum ALT level, but this was not so for the women. The disparity of ALT in age groups was revealed. Several sex-related differences were indicated pertaining to the prevalence of an elevated serum ALT level among elderly specific occupational population.

  15. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  16. Use of serum and blood samples on filter paper to improve the surveillance of Dengue in Pacific Island Countries.

    Science.gov (United States)

    Aubry, Maite; Roche, Claudine; Dupont-Rouzeyrol, Myrielle; Aaskov, John; Viallon, Jérôme; Marfel, Maria; Lalita, Paul; Elbourne-Duituturaga, Salanieta; Chanteau, Suzanne; Musso, Didier; Pavlin, Boris I; Harrison, Dustin; Kool, Jacob L; Cao-Lormeau, Van-Mai

    2012-09-01

    In Pacific Island Countries (PICs) the epidemiology of dengue is characterized by long-term transmission of a single dengue virus (DENV) serotype. The emergence of a new serotype in one island country often indicates major outbreaks with this serotype will follow in other PICs. Filter paper (FP) cards on which whole blood or serum from dengue suspected patients had been dried was evaluated as a method for transportation of this material by standard mail delivery throughout the Pacific. Twenty-two FP-dried whole blood samples collected from patients in New Caledonia and Wallis & Futuna Islands, during DENV-1 and DENV-4 transmission, and 76 FP-dried sera collected from patients in Yap State, Majuro (Republic of Marshall Islands), Tonga and Fiji, before and during outbreaks of DENV-2 in Yap State and DENV-4 in Majuro, were tested for the presence of DENV RNA, by serotype specific RT-PCR, at the Institut Louis Malardé in French Polynesia. The serotype of DENV could be determined, by a variety of RT-PCR procedures, in the FP-dried samples after more than three weeks of transport at ambient temperatures. In most cases, the sequencing of the envelope gene to genotype the viruses also was possible. The serotype and genotype of DENV can be determined from FP-dried serum or whole blood samples transported over thousands of kilometers at ambient, tropical, temperatures. This simple and low-cost approach to virus identification should be evaluated in isolated and resource poor settings for surveillance for a range of significant viral diseases. Copyright © 2012. Published by Elsevier B.V.

  17. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  18. Evaluation of HER2/neu oncoprotein in serum & tissue samples of women with breast cancer

    Directory of Open Access Journals (Sweden)

    Shailaja Shukla

    2016-01-01

    Interpretation & conclusions: The results suggest that elevated serum HER2 level was associated with a clinicopathological aggressive phenotype of breast carcinoma and was related to tissue HER2 overexpression. Therefore, serum HER2 may be useful for monitoring the course of the disease and response to treatment.

  19. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  20. Sample size of the reference sample in a case-augmented study.

    Science.gov (United States)

    Ghosh, Palash; Dewanji, Anup

    2017-05-01

    The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  1. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  2. Advanced prostatic carcinomas with low serum levels of prostate-specific antigen

    Directory of Open Access Journals (Sweden)

    Cerović Snežana J.

    2002-01-01

    Full Text Available The serum levels of prostate-specific antigen (PSA represent a significant diagnostic and monitoring parameter of prostatic carcinoma (PC. The aim of the study was to establish correlation of serum PSA level in addition to grade, histological type, and clinical stage of PC in patients with normal or intermediary PSA serum level. In 37 untreated PC patients with preoperative serum PSA levels ranging between 0.1 and 9.6 ng/ml, paraffin-embedded tissue and serum samples were immunohistological studied and immunoassay for PSA was done. The most representative was poorly differentiated PC with D stage In serum samples from PC patients 27 (73.7% normal (≤ 4.0 ng/ml, and 10 (27.3% intermediate (4.1-10 ng/ml PSA levels were found Immunohistochemistry, in 36 PC (97.3% had demonstrated the expression of PSA. Our study results had shown low serum PSA levels in some patients with advanced poorly differentiated PC.

  3. 7 CFR 27.25 - Additional samples of cotton; drawing.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Additional samples of cotton; drawing. 27.25 Section... Samples § 27.25 Additional samples of cotton; drawing. In addition to the samples hereinbefore prescribed, separate samples, if desired, may be drawn and furnished to the owner of the cotton. ...

  4. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  5. Maldi-Tof /Tof-MS Reveals Elevated Serum Haptoglobin and Amyloid A in Behcet's Disease

    NARCIS (Netherlands)

    Mao, L.; Dong, H.; Yang, P.; Zhou, H.; Huang, X.; Lin, X.; Kijlstra, A.

    2008-01-01

    Behcet¿s disease (BD) is a multisystemic autoimmune disease with unclear etiology and pathogenesis. To screen aberrant serum proteins in BD, serum samples were obtained from eight male BD patients with active uveitis and eight male healthy volunteers with informed consent. The serum samples from

  6. Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.

    Science.gov (United States)

    Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto

    2017-04-01

    Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  8. Environmental and economic impacts of fertilizer drawn forward osmosis and nanofiltration hybrid system

    KAUST Repository

    Kim, Jung Eun; Phuntsho, Sherub; Chekli, Laura; Hong, Seungkwan; Ghaffour, NorEddine; Leiknes, TorOve; Choi, Joon Yong; Shon, Ho Kyong

    2017-01-01

    Environmental and economic impacts of the fertilizer drawn forward osmosis (FDFO) and nanofiltration (NF) hybrid system were conducted and compared with conventional reverse osmosis (RO) hybrid scenarios using microfiltration (MF) or ultrafiltration

  9. Structure evolution and mechanical behavior of poly(ethylene terephthalate fibers drawn at different number of drawing stages

    Directory of Open Access Journals (Sweden)

    Haji Aminoddin

    2012-01-01

    Full Text Available In this work, the structure, mechanical and thermal properties of PET fiber obtained by hot multi-stage drawing have been investigated in terms of their dependence on the number of drawing steps at an equivalent total draw ratio. Differential scanning calorimetry, birefringence, wide-angle x-ray diffraction, FTIR spectroscopy, tensile properties, and taut-tie molecules were used to characterize the fine structure and physical properties of the fibers. Results have been explained in terms of a higher drawing residence time at an equivalent drawing speed. For single stage drawn fiber, a high tensile strength is obtained, whereas a high initial modulus is obtained for fiber drawn at three-stage drawing. According to the results, an important finding is that three-stage drawing process has the potential to produce high-modulus fibers. The enhanced fraction of taut-tie molecules is found in three-stage drawn fiber, which is believed to be one of the important factors leading to the high modulus achieved in fibers drawn in hot multistage.

  10. Serum erythropoietin levels by radioimmunoassay in polycythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Birgegaard, G.; Miller, O.; Caro, J.; Erslev, A. (Cardeza Foundation for Hematological Research, Jefferson University, Philadelphia, Pa.)

    1982-01-01

    A radioimmunoassay (RIA) method for erythropoietin (Epo) was developed and validated against the polycythaemic mouse assay. The correlation was good, with a r=0.94. Several other criteria of specificity were also filled by the RIA, which had a lower detection limit of 5 mU/ml. The mean serum-Epo level in 6 patients with secondary polycythaemia, 50.2 +- 26.2 mU/ml, was significantly higher than in a group of 11 normal subjects, 28.7 +- 7.2 mU/ml (P<0.0002). However, the Epo level in 31 polycythaemia vera (PV) patients, M = 21.9 +- 6.6 mU/ml, was not significantly different from normal (P = 0.006). Since previous studies with bioassay of heat-treated and concentrated plasma samples have shown a decreased serum-Epo level in PV, Epo levels were measured before and after heat treatment and concentration of samples from normals and polycythaemics. It was found that the levels of immunoreactive material increased after heat treatment and 40 times concentration in samples from normals and patients with secondary polycythaemias, but decreased in PV. We conclude that the Epo levels in serum in the low range measured by our and previous RIA:s probably are not true Epo levels but are partly due to an unspecific serum effect, that was removed by heat treatment.

  11. Relationships between coronary heart disease risk factors and serum ionized calcium in Kennedy Space Center Cohort

    Science.gov (United States)

    Goodwin, Lisa Ann; Frey, Mary Anne Bassett; Merz, Marion P.; Alford, William R.

    1987-01-01

    Kennedy Space Center (KSC) employees are reported to be at high risk for coronary heart disease (CHD). Risk factors for CHD include high serum total cholesterol levels, low levels of high-density lipoprotein cholesterol (HDLC), elevated triglyceride, smoking, inactivity, high blood pressure, being male, and being older. Higher dietary and/or serum calcium Ca(++) may be related to a lower risk for CHD. Fifty men and 37 women participated. Subjects were tested in the morning after fasting 12 hours. Information relative to smoking and exercise habits was obtained; seated blood pressures were measured; and blood drawn. KCS men had higher risk values than KCS women as related to HDLC, triglycerides, systolic blood pressure, and diastolic blood pressure. Smoking and nonsmoking groups did not differ for other risk factors or for serum Ca(++) levels. Exercise and sedentary groups differed in total cholesterol and triglyceride levels. Serum Ca(++) levels were related to age, increasing with age in the sedentary group and decreasing in the exercisers, equally for men and women. It is concluded that these relationships may be significant to the risk of CHD and/or the risk of bone demineralization in an aging population.

  12. [Trend of the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Retrospective analysis of serum samples of the years 2006-2015].

    Science.gov (United States)

    Müller, A; Freude, B

    2016-01-01

    An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45  068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40  949 samples (30  462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply,  150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.

  13. Aspects of the Hematology and Serum Biochemistry of Sahel and ...

    African Journals Online (AJOL)

    This study was conducted to investigate effects of year, age, season and breeds on aspects of the hematology and serum biochemical indices of Sahel and Sokoto red bucks in Mubi, Adamawa state, Nigeria. Blood and serum samples were used to determine PCV, Hb, RBC and WBC, and while serum protein (BSP) and ...

  14. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. The Pilot Study of the Effect of Meditation to the Serum Brain-Derived Neurotrophic Factor (BDNF) of Medical Students, Srinakharinvirot University.

    Science.gov (United States)

    Turakitwanakan, Wanpen; Mekseepralard, Chantana; Busarakumtragul, Panaree

    2015-11-01

    Mindfulness meditation is a method to decrease stress and increase memory. So, mindfulness meditation should increase serum brain-derived neurotrophic factor (BDNF). To study the effect of mindfulness meditation on the serum BDNF of medical students. The study group consisted of 30 male and female second-year medical students that volunteered to participate in the study, aged 19.1 ± 0.55 year olds (range 18-20) from Srinakharinwirot University. Their blood was drawn to measure BDNF before and after a four-day mindfulness meditation programme. The comparison of serum BDNF levels before and after meditation were analysed by paired t-test. The subjects were 66.77%female and 33.33% male. The average serum BDNF level before the meditation was 17.67 ng/ml (SD 3.58). After meditation, there was a decrease in serum BDNF to 17.34 ng/ml, which was however not statistically significant (SD 4.04, p > 0.05). The levels of blood BDNF decreases slightly after practising meditation. We plan to investigate the reason in the future.

  16. Rapid detection of cytomegalovirus in bronchoalveolar lavage fluid and serum samples by polymerase chain reaction: correlation of virus isolation and clinical outcome for patients with human immunodeficiency virus infection

    DEFF Research Database (Denmark)

    Hansen, K K; Vestbo, Jørgen; Benfield, T

    1997-01-01

    Bronchoalveolar lavage (BAL) fluids and serum samples from 153 patients with pulmonary symptoms who were infected with human immunodeficiency virus (HIV) and underwent BAL were examined for the presence of cytomegalovirus (CMV) by conventional culture and by polymerase chain reaction (PCR...... technique than conventional culture. Detection of CMV DNA in BAL fluid or serum predicted subsequent development of extrapulmonary CMV disease but not death for HIV-infected patients with pulmonary symptoms....

  17. Competitive radioimmunoassay of digoxin in serum

    International Nuclear Information System (INIS)

    Oslapas, Raymond; Herrin, T.R.

    1975-01-01

    The process described is for determining the digoxin level of a serum. To do so a mixture is made by adding to the serum sample an antidigoxin antibody and a suitable labelling quantity of O 3 -(hydroxy-4 phenethylcarbamoyl)digoxigenin for radioactive labelling. The mixture is allowed to incubate so that the digoxin of the sample and the radioactive labelling reagent joint to the antidigoxin antibody. A precipitating agent is added to the mixture to help the formation of a precipitate and thus separate the labelled digoxin taken up from the precipitate free digoxin. The liquid is separated from the precipitate formed and the residual radioactivity of the precipitate is measured [fr

  18. Methylphenidate Ameliorates Depressive Comorbidity in ADHD Children without any Modification on Differences in Serum Melatonin Concentration between ADHD Subtypes

    Directory of Open Access Journals (Sweden)

    Isabel Cubero-Millán

    2014-09-01

    Full Text Available The vast majority of Attention-deficit/hyperactivity disorder (ADHD patients have other associated pathologies, with depressive symptoms as one of the most prevalent. Among the mediators that may participate in ADHD, melatonin is thought to regulate circadian rhythms, neurological function and stress response. To determine (1 the serum baseline daily variations and nocturnal excretion of melatonin in ADHD subtypes and (2 the effect of chronic administration of methylphenidate, as well as the effects on symptomatology, 136 children with ADHD (Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision: DSM-IV-TR criteria were divided into subgroups using the “Children’s Depression Inventory” (CDI. Blood samples were drawn at 20:00 and 09:00 h, and urine was collected between 21:00 and 09:00 h, at inclusion and after 4.61 ± 2.29 months of treatment. Melatonin and its urine metabolite were measured by radioimmunoassay RIA. Factorial analysis was performed using STATA 12.0. Melatonin was higher predominantly in hyperactive-impulsive/conduct disordered children (PHI/CD of the ADHD subtype, without the influence of comorbid depressive symptoms. Methylphenidate ameliorated this comorbidity without induction of any changes in the serum melatonin profile, but treatment with it was associated with a decrease in 6-s-melatonin excretion in both ADHD subtypes. Conclusions: In untreated children, partial homeostatic restoration of disrupted neuroendocrine equilibrium most likely led to an increased serum melatonin in PHI/CD children. A differential cerebral melatonin metabolization after methylphenidate may underlie some of the clinical benefit.

  19. Serum bicarbonate and dehydration severity in gastroenteritis

    OpenAIRE

    Narchi, H.

    1998-01-01

    The concentration of bicarbonate was measured in serum samples from 106 children with gastroenteritis and dehydration. A concentration less than 22 mmol/l was more common in children with severe dehydration, but the magnitude of bicarbonate reduction was not significantly different with increasing degrees of dehydration. Doctors should not rely on the serum bicarbonate concentration when assessing fluid deficit.



  20. Impact of Prolonged Blood Incubation and Extended Serum Storage at Room Temperature on the Human Serum Metabolome

    Directory of Open Access Journals (Sweden)

    Beate Kamlage

    2018-01-01

    Full Text Available Metabolomics is a powerful technology with broad applications in life science that, like other -omics approaches, requires high-quality samples to achieve reliable results and ensure reproducibility. Therefore, along with quality assurance, methods to assess sample quality regarding pre-analytical confounders are urgently needed. In this study, we analyzed the response of the human serum metabolome to pre-analytical variations comprising prolonged blood incubation and extended serum storage at room temperature by using gas chromatography-mass spectrometry (GC-MS and liquid chromatography-tandem mass spectrometry (LC-MS/MS -based metabolomics. We found that the prolonged incubation of blood results in a statistically significant 20% increase and 4% decrease of 225 tested serum metabolites. Extended serum storage affected 21% of the analyzed metabolites (14% increased, 7% decreased. Amino acids and nucleobases showed the highest percentage of changed metabolites in both confounding conditions, whereas lipids were remarkably stable. Interestingly, the amounts of taurine and O-phosphoethanolamine, which have both been discussed as biomarkers for various diseases, were 1.8- and 2.9-fold increased after 6 h of blood incubation. Since we found that both are more stable in ethylenediaminetetraacetic acid (EDTA blood, EDTA plasma should be the preferred metabolomics matrix.

  1. Iron and ADHD: Time to Move beyond Serum Ferritin Levels

    Science.gov (United States)

    Donfrancesco, Renato; Parisi, Pasquale; Vanacore, Nicola; Martines, Francesca; Sargentini, Vittorio; Cortese, Samuele

    2013-01-01

    Objective: (a) To compare serum ferritin levels in a sample of stimulant-naive children with ADHD and matched controls and (b) to assess the association of serum ferritin to ADHD symptoms severity, ADHD subtypes, and IQ. Method: The ADHD and the control groups included 101 and 93 children, respectively. Serum ferritin levels were determined with…

  2. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    Science.gov (United States)

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  3. Selenium status of South Bohemia seniors characterized by INAA of blood serum

    International Nuclear Information System (INIS)

    Kvicala, J.; Zamrazil, V.; Nemecek, J.; Jiranek, J.

    2008-01-01

    To estimate the status of selenium in seniors of the South Bohemia region, Czech Republic, 481 serum samples from seniors living in 17 Asylum Houses for seniors in the age between 60 and 99 years were obtained. Samples were analyzed by instrumental neutron activation analysis with concurrent analysis of 4 reference materials for quality assurance. Average concentration of serum Se, arithmetic means in individual Asylum Houses, frequency distribution of serum Se concentrations as well as five years running monitoring of serum Se concentrations of one group of seniors proved selenium deficiency of the elderly population of the region South Bohemia. (author)

  4. Effect of Ramadan fasting on serum heat shock protein 70 and serum lipid profile.

    Science.gov (United States)

    Zare, A; Hajhashemi, M; Hassan, Z M; Zarrin, S; Pourpak, Z; Moin, M; Salarilak, S; Masudi, S; Shahabi, S

    2011-07-01

    Ramadan, the holy month for the Islamic world, is a period every year when food and fluid intake is restricted to the pre-sunrise and post-sunset hours. The aim of this study was to evaluate the effect of Ramadan fasting on the serum concentration of heat shock protein 70 (HSP70) and serum lipid profile in healthy men. A total of 32 male volunteers with a mean age of 28.5 (range 23-37) years were selected for the study. Blood samples were obtained one day prior to Ramadan and on the 3rd and 25th days of fasting. Serum HSP70, triglyceride (TG), cholesterol (Chol), low-density lipoprotein (LDL) and high-density lipoprotein (HDL), LDL/HDL and Chol/HDL ratios were investigated. It was observed that the mean concentrations of serum HSP70 and HDL on the 25th day of Ramadan were significantly higher than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels on the 3rd day of Ramadan was significantly higher than those recorded one day before Ramadan. Mean concentrations of serum TG, Chol, LDL, and LDL/HDL and Chol/HDL ratios on the 25th day of Ramadan were significantly lower than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels found on the 3rd day of Ramadan were also significantly lower than those recorded one day before Ramadan. Ramadan fasting increases serum HSP70 and improves serum lipid profile.

  5. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  6. Serum insulin like growth factor-1 is associated with working memory, executive function and selective attention in a sample of healthy, fit older adults.

    Science.gov (United States)

    Bellar, D; Glickman, E L; Juvancic-Heltzel, J; Gunstad, J

    2011-03-31

    The present study examined the association between serum insulin like growth factor-1 (IGF-1) concentrations and cognitive function in a sample of healthy, fit older adults (age: 70.8±9.3 years, body mass index (BMI): 27.3±5.7). Participants reported to the laboratory and basic anthropometric data were collected, followed by a fasted blood draw to quantify serum IGF-1. Participants then underwent cognitive testing that included the Mini-Mental Status Exam (MMSE), Trail Making Test A and B, Ruff's 2 and 7 test of selective attention and Letter Number Sequencing. Results showed the participants were generally cognitively intact (MMSE 27.6±1.8). Significant partial correlations (controlled for age, gender and years of education) emerged between serum IGF-1 concentrations and the total (r=0.381, P=0.030) and longest trial (r=0.455, P=0.011) on Letter Number Sequencing. Similar partial correlations yielded significant relationships between serum IGF-1 and Ruff's Automatic Detection Errors (r=-0.495, P=0.006), Controlled Speed Errors (r=-0.598, P=0.002) and errors made on the Trial Making Test part B (r=-0.466, P=0.010). These findings suggest that fasting levels of serum IGF-1 are related to higher levels of cognitive performance in healthy older adults, including working memory, selective attention and executive function. Further work is needed to more clearly determine possible mechanisms. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  7. Effect of storage duration on cytokine stability in human serum and plasma.

    Science.gov (United States)

    Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James

    2018-06-14

    Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix.

    Science.gov (United States)

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-11-30

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.

  9. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    International Nuclear Information System (INIS)

    Schuettler, J.; White, P.F.

    1984-01-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories

  10. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, J.; White, P.F.

    1984-09-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.

  11. Influence of the collection tube on metabolomic changes in serum and plasma.

    Science.gov (United States)

    López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D

    2016-04-01

    Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  13. A study of serum lipid profile and serum apolipoproteins A1 and B in Indian male violent criminal offenders.

    Science.gov (United States)

    Chakrabarti, Nandini; Sinha, V K

    2006-01-01

    High cholesterol has been advanced as the most important factor in the development of coronary artery disease. Most panels have recommended population-wide dietary restrictions, yet a body of evolving data yields evidence of the hazards of low cholesterol, including links to aggression and hostility. The aim of this study was to compare the serum lipid profile and serum apolipoproteins A1 and B of men with a violent criminal record and men with no criminal history. Fasting blood samples were collected from 30 men with a known history of violent crime and 30 men with no criminal record. Serum lipid profile and serum apolipoproteins A1 and B were measured in each sample, and compared between the two groups. The group with the violent criminal record showed significantly lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B compared with the control group. Lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B could predispose to violence. Future research might explore the possibility that diets offered in prison could affect relevant pathways in lipid metabolism. Copyright (c) 2006 John Wiley & Sons, Ltd.

  14. Organic cattle products: Authenticating production origin by analysis of serum mineral content.

    Science.gov (United States)

    Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta

    2018-10-30

    An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Clinical and biochemical assessment of high serum vitamin B12 levels

    DEFF Research Database (Denmark)

    Arendt, Johan Frederik Berg; Nexø, Ebba

    2012-01-01

    Introduction: Measurement of serum cobalamin (Cbl) is routinely used to assess suspected Cbl deficiency. Surprisingly, 15% of all samples analysed for serum Cbl show values above the reference range of 200-600 pmol/L. Aim: We hypothesized that increased Cbl levels are caused by alterations...... in the circulating Cbl binding proteins haptocorrin (HC) and/or transcobalamin (TC), and that such changes may be of clinical importance. Materials and methods: We collected 834 blood samples from hospital treated patients with serum Cbl levels: 1000 pmol/L. In-house ELISAs were used...

  16. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  17. Impact of reverse nutrient diffusion on membrane biofouling in fertilizer-drawn forward osmosis

    KAUST Repository

    Li, Sheng; Kim, Youngjin; Chekli, Laura; Phuntsho, Sherub; Shon, Ho Kyong; Leiknes, TorOve; Ghaffour, NorEddine

    2017-01-01

    Biofouling in fertilizer-drawn forward osmosis (FDFO) for water reuse was investigated by spiking pure bacteria species Pseudomonas aeruginosa PAO1+GFP and using three different fertilizers KNO3, KCl and KH2PO4 as draw solutions. The performance

  18. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix

    OpenAIRE

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-01-01

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The ...

  19. Factors in selecting serum samples for use in determining the positive/negative threshold (cut-off) in ELISA

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    The threshold (cut-off) that defines whether a test result is seropositive or seronegative is calculated by testing serum samples from a subpopulation of animals that is assumed to represent the target population in all aspects. For this proposition to be true, it is essential to consider the variables in the target population that must be represented in the subpopulation. Without representation of the variables in the subpopulation, it is likely that the cut-off selected for the test will be errant and will misclassify animals as to their infection status. The purpose of this paper is to identify a few of the principal variables that need to be taken into account when selecting a subpopulation of animals for test validation. (author)

  20. Prognostic implication of serum hepatocyte growth factor in stage II/III breast cancer patients who received neoadjuvant chemotherapy.

    Science.gov (United States)

    Kim, Hyori; Youk, Jeonghwan; Yang, Yaewon; Kim, Tae-Yong; Min, Ahrum; Ham, Hye-Seon; Cho, Seongcheol; Lee, Kyung-Hun; Keam, Bhumsuk; Han, Sae-Won; Oh, Do-Youn; Ryu, Han Suk; Han, Wonshik; Park, In Ae; Kim, Tae-You; Noh, Dong-Young; Im, Seock-Ah

    2016-03-01

    In stage II/III breast cancer, neoadjuvant chemotherapy (NAC) is a standard treatment. Although several biomarkers are used to predict prognosis in breast cancer, there is no reliable predictive biomarker for NAC success. Recently, the hepatocyte growth factor (HGF) and cMet signaling pathway demonstrated to be involved in breast cancer tumor progression, and its potential as a biomarker is under active investigation. In this study, we assessed the potential of serum HGF as a prognostic biomarker for NAC efficacy. Venous blood samples were drawn from patients diagnosed with stage II/III breast cancer and treated with NAC in Seoul National University Hospital from August 2004 to November 2009. Serum HGF level was determined using an ELISA system. We reviewed the medical records of the patients and investigated the association of HGF level with patients' clinicopathologic characteristics. A total of 121 female patients (median age = 45 years old) were included. Median level of HGF was 934 pg/ml (lower quartile: 772, upper quartile: 1145 pg/ml). Patients with higher HGF level than median value were significantly more likely to have clinically detectable regional node metastasis (p = 0.017, Fisher's exact test). Patients with complete and partial response according to the American Joint Committee on Cancer 7th Edition criteria tended to have higher HGF level (p = 0.105 by t test). Patients with an HGF level higher than the upper quartile value had longer relapse-free survival than the other patients (106 vs. 85 months, p = 0.008). High serum HGF levels in breast cancer patients are associated with clinically detectable regional node metastasis and, paradoxically, with longer relapse-free survival in stage II/III breast cancer.

  1. [Cultivation of a permanent fish cell line in serum-free media special experiences with a cytotoxicity test for waste water samples

    Science.gov (United States)

    Kohlpoth, Martin; Rusche, Brigitte

    1997-01-01

    The use of fetal calf serum (FCS) as standard medium additive for the cell cultivation must be regarded critically from the point of view of animal welfare as well as for scientific reasons and makes it necessary to look for alternatives. In the last years an in vitro cytotoxicity assay for the testing of industrial waste waters with the permanent fish cell line RTG-2 was established and pre-validated as an alternative to the fish test with the golden orfe. The application of FCS is also a special problem with regard to the testing of waste waters in a cytotoxicity test so that FCS-alternatives were tested. The RTG-2 cells were successfully adapted to the two solvents Basal Medium Supplement (BMS) and Ultroser-G (U-G) that are used to replace serum. The characterisation of these adapted cell lines showed no significant differences in growth rate, adhesion rate, viability and sensitivity to chemicals in comparison to the original RTG-2 cells. On the determination of the cytotoxicity of industrial waste waters the RTG-2 cells adapted to the BMS medium indicated a clearly higher toxicity of the waste water samples than the original RTG-2 cells. This result confirms the thesis that serum components react with waste water elements and thus change the bio-availability of toxic compounds.

  2. Evaluation of serum and milk ELISAs for paratuberculosis in Danish dairy cattle

    DEFF Research Database (Denmark)

    Klausen, Joan; Huda, A.; Ekeroth, Lars

    2003-01-01

    concurrently from six dairy herds infected with MAP and from two dairy herds without history of infection with MAP. A cut-off value of 7 OD% was used in the ELISAs. At this cut-off value, all six culture-positive herds were positive in the serum ELISA but one was negative in the milk ELISA. All six culture......-positive herds were positive in the CFT. In the two culture-negative herds, the serum and the milk ELISA deemed all serum samples negative at this cut-off value, whereas four serum samples from one of these herds were positive in the CFT. The highest cut-off value enabling the milk ELISA to record all six...... culture-positive herds as positive was 4 OD%. The highest cut-off value enabling the serum ELISA to record all six culture-positive herds as positive was 17 OD%. Individual-sample relative sensitivities of the ELISAs ranged from 49 to 64% and relative specificities were 80-96% at the cut-off values of 4...

  3. New sampling strategy using a Bayesian approach to assess iohexol clearance in kidney transplant recipients.

    Science.gov (United States)

    Benz-de Bretagne, I; Le Guellec, C; Halimi, J M; Gatault, P; Barbet, C; Alnajjar, A; Büchler, M; Lebranchu, Y; Andres, Christian Robert; Vourcʼh, P; Blasco, H

    2012-06-01

    Glomerular filtration rate (GFR) measurement is a major issue in kidney transplant recipients for clinicians. GFR can be determined by estimating the plasma clearance of iohexol, a nonradiolabeled compound. For practical and convenient application for patients and caregivers, it is important that a minimal number of samples are drawn. The aim of this study was to develop and validate a Bayesian model with fewer samples for reliable prediction of GFR in kidney transplant recipients. Iohexol plasma concentration-time curves from 95 patients were divided into an index (n = 63) and a validation set (n = 32). Samples (n = 4-6 per patient) were obtained during the elimination phase, that is, between 120 and 270 minutes. Individual reference values of iohexol clearance (CL(iohexol)) were calculated from k (elimination slope) and V (volume of distribution from intercept). Individual CL(iohexol) values were then introduced into the Bröchner-Mortensen equation to obtain the GFR (reference value). A population pharmacokinetic model was developed from the index set and validated using standard methods. For the validation set, we tested various combinations of 1, 2, or 3 sampling time to estimate CL(iohexol). According to the different combinations tested, a maximum a posteriori Bayesian estimation of CL(iohexol) was obtained from population parameters. Individual estimates of GFR were compared with individual reference values through analysis of bias and precision. A capability analysis allowed us to determine the best sampling strategy for Bayesian estimation. A 1-compartment model best described our data. Covariate analysis showed that uremia, serum creatinine, and age were significantly associated with k(e), and weight with V. The strategy, including samples drawn at 120 and 270 minutes, allowed accurate prediction of GFR (mean bias: -3.71%, mean imprecision: 7.77%). With this strategy, about 20% of individual predictions were outside the bounds of acceptance set at ± 10

  4. Air-structured optical fibre drawn from a 3D-printed preform

    OpenAIRE

    Cook, Kevin; Canning, John; Leon-Saval, Sergio; Reid, Zane; Hossain, Md Arafat; Comatti, Jade-Edouard; Luo, Yanhua; Peng, Gang-Ding

    2016-01-01

    A structured optical fibre is drawn from a 3D-printed structured preform. Preforms containing a single ring of holes around the core are fabricated using filament made from a modified butadiene polymer. More broadly, 3D printers capable of processing soft glasses, silica and other materials are likely to come on line in the not-so distant future. 3D printing of optical preforms signals a new milestone in optical fibre manufacture.

  5. Does the time interval between antimüllerian hormone serum sampling and initiation of ovarian stimulation affect its predictive ability in in vitro fertilization-intracytoplasmic sperm injection cycles with a gonadotropin-releasing hormone antagonist?

    DEFF Research Database (Denmark)

    Polyzos, Nikolaos P; Nelson, Scott M; Stoop, Dominic

    2013-01-01

    To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response.......To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response....

  6. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    Science.gov (United States)

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  7. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    International Nuclear Information System (INIS)

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  8. The 226Ra isotope activities in ground water samples drawn of two wells from the Meridional Pluton, Morungaba Granitoids, eastern Sao Paulo State; Atividades do 226Ra em aguas subterraneas extraidas de dois pocos localizados no pluton meridional, granitoides de Morungaba, SP

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, Fabio de Oliveira; Silva Junior, Mario Goncalves da; Bertolla, Luciana; Ribeiro, Fernando Brenha [Sao Paulo Univ., SP (Brazil). Inst. de Astronomia, Geofisica e Ciencias Atmosfericas. Dept. de Geofisica]. E-mail: brenha@iag.usp.br

    2005-07-01

    The 226Ra activities, both in solution and associated with suspended solids, were measured in ground water samples drawn from two wells drilled in a fractured granitic aquifer from the Meridional Pluton, Morungaba Granitoids, eastern Sao Paulo State. The 226Ra isotope activities were measured in a sequence of samples collected about one month apart between March, 2003 and April 2004. The 226Ra activities were measured by radon gas emanometry. The mean dissolved 226Ra activity concentration activities observed in the two wells were (44.9 {+-} 7.1) mBq/L and (51.6 {+-} 8.8) mBq/L. The 226Ra activity of the suspend solids in a liter of these waters varied between (0,6 {+-} 0,1) mBq and (13 {+-} 1) mBq, respectively. (author)

  9. Genetic factors explain half of all variance in serum eosinophil cationic protein

    DEFF Research Database (Denmark)

    Elmose, Camilla; Sverrild, Asger; van der Sluis, Sophie

    2014-01-01

    with variation in serum ECP and to determine the relative proportion of the variation in ECP due to genetic and non-genetic factors, in an adult twin sample. METHODS: A sample of 575 twins, selected through a proband with self-reported asthma, had serum ECP, lung function, airway responsiveness to methacholine......, exhaled nitric oxide, and skin test reactivity, measured. Linear regression analysis and variance component models were used to study factors associated with variation in ECP and the relative genetic influence on ECP levels. RESULTS: Sex (regression coefficient = -0.107, P ... was statistically non-significant (r = -0.11, P = 0.50). CONCLUSION: Around half of all variance in serum ECP is explained by genetic factors. Serum ECP is influenced by sex, BMI, and airway responsiveness. Serum ECP and airway responsiveness seem not to share genetic variance....

  10. Serum zinc and copper levels in children with febrile convulsion

    Directory of Open Access Journals (Sweden)

    Mohammad Shokrzadeh

    2016-09-01

    Full Text Available Febrile convulsions (FC are the most common neurologic disorder in children 6-60 months of age. Zinc (Zn and copper (Cu play role as cofactors in more than 300 enzymatic activities significantly. The aim of this study was to evaluate the relationship serum levels of Zn and Cu with seizure occurrence in febrile children. In this case-control study, 270 children with 6 month to 6 years were evaluated. The patients were enrolled in three groups: a children with febrile convulsion, b febrile children without convulsion and c healthy ones. After recording of all patients’ characteristics, 5 mL blood was taken from peripheral vessels at the first 12 hours of hospitalization. Absorption of all samples was read by BRAIC (Rayleigh instrument company, WFX-130 model with calibration diagram, considering samples dilution levels. The mean of serum Zn levels in children with FC were significantly lower than other two groups. Mean serum Cu levels in children with FC and non-FC patients were significantly higher than healthy children. No meaningful differences were observed in serum levels of Zn and Cu among the girl or boy cases. This study showed significant lower serum zinc level in children with febrile seizure and meaningful higher serum copper level than control group cases. There was no significant difference in level of serum zinc and copper in term of sex.

  11. Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL

    Directory of Open Access Journals (Sweden)

    Gurmukh Singh

    2015-04-01

    Full Text Available Objective: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. Methods: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a evidence of corrective action in patients with serum folate values 25.7 ng/mL. Results: The prevalence of serum folate levels, in patients, 25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate 60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL. Keywords: Serum folate, Prevalence of folate deficiency, Neural tube defects, Optimum serum folate level, Utility of folate testing

  12. Value of serum tenascin-C in patients with acute myocardial infarction

    African Journals Online (AJOL)

    Rania Gaber

    2015-10-09

    Oct 9, 2015 ... Aliquots of serum were delivered into Eppendorf tubes. Serum samples have been .... Tenascin-C induced by aldosterone-mediated inflammation. J · Cardiovasc .... nosis estimation and targeted therapy. Cell Adh Migr 2015 ...

  13. Fiber vs Rolling Texture: Stress State Dependence for Cold-Drawn Wire

    Science.gov (United States)

    Zorina, M. A.; Karabanalov, M. S.; Stepanov, S. I.; Demakov, S. L.; Loginov, Yu. N.; Lobanov, M. L.

    2018-02-01

    The texture of the cold-drawn copper wire was investigated along the radius using electron backscatter diffraction. The complex fiber texture of the central region of the wire was considered as the rolling texture consisting of a set of preferred orientations. The texture of the periphery region was revealed to be similar to the shear texture. The orientation-dependent properties of the wire were proven to be determined by the texture of the near-surface layers.

  14. Mechanical and metallurgical changes on 308L wires drawn by electropulses

    OpenAIRE

    Sánchez Egea, Antonio José; González Rojas, Hernan Alberto; Celentano, Diego Javier; Jorba Peiró, Jordi

    2015-01-01

    The electroplastic effects resulting from different electropulses configurations on a wire drawing process are investigated experimentally and numerically. Electropulses are induced into 308L stainless steel while it is simultaneously wire drawn. A current density of 185 A/mm2, a frequency range from 140 to 355 Hz and a pulse duration range from 100 to 250 µs are combined to electrically assist the wire drawing process. The electropulsing influence is studied in several mechanical parameters,...

  15. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  16. Some comments on the effectiveness of the therapy for Β-thalassemia

    Science.gov (United States)

    Jiang, K.; Ma, W. Y.; Ortalli, I.; Pedrazzi, G.; Zhang, X.; Izzi, G. C.

    1994-12-01

    In the present study, twenty-five samples of red blood cells (RBCs) and two samples of lyophilized serum, drawn from thirteen patients with Β-thanassemia major, have been examined by Mössbauer spectroscopy. All these patients undergo long-term therapy by regular blood transfusion and deferoxamine. The samples were obtained at the end of one cycle of treatments, before the successive blood transfusion. The results show, within the experimental errors, that the ferritin-like iron appears to be absent in the RBCs of the patients but it is still present in the serum.

  17. Plasma as alternatively sample to quantify tetanus antitoxin

    Directory of Open Access Journals (Sweden)

    Ariel Menéndez-Barrios

    2015-08-01

    Full Text Available Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce aspecific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample. The possible use of plasma obtained from plasmapheresis as alternative sample was evaluated in this research, to minimize the volume of total blood extracted to the donors. One hundred plasma donors who came to donate between October and November 2013 were selected by simple random sampling. Serum sample was obtained for extraction of 5 mL of blood, deposited in dry glass tube. While the other sample took 1.5 mL of plasma in a plastic tube with cover, at the end of the donation directly of the unit of plasma collected. Comparison of the difference between the means of both groups was done using SPSS for Windows. It was found that the values obtained in serum were bigger than those obtained in plasma. Difference between the means of both groups was statistically significant (p 0.00. It is not advisable to use the obtained plasma of the plasmapheresis as analytic sample in this assay.

  18. Kinetics of human serum amyloid A

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Martin, M.E.; Solomon, N.

    1986-01-01

    In order to better understand the pathogenetic role of serum amyloid A (SAA) we studied the kinetics of 131 I radiolabelled pure SAA, extracted from 400 ml serum of a human volunteer. 50 microCi of 131 I SAA and 15 microCi 125 I labelled sodium iodide were administered i.v. on two occasions at 6 month intervals. Serum and plasma samples were collected at 10-20 min intervals x 10, then once daily x 10; lymphocytes were separated from monocytes and granulocytes. Counts per minute of 131 I and 125 I were measured in each sample in the serum, in serum precipitates resulting after addition of a rabbit anti-SAA antibody and of TCA and in various cell subpopulations as well as in the whole urine and TCA precipitated urine from each micturition. The 131 I disappearance curves from the plasma and serum precipitates were semilogarithmically plotted; cumulative 131 I cpm in plasma, cells and urine at various intervals were determined. Body scanning was performed at 2, 16, and 48 h. The results of the two experiments were very similar. The curve of 131 I SAA in plasma TCA precipitates indicated the existence of 4 compartments likely due to uptake of 131 I SAA by some plasma proteins, circulating cells and other tissues; later release from tissues started at 6 h. The 131 I SAA half-life time in these compartments was found to be 35, 170, 255, and 550 min, respectively. Tissue binding of 131 I was also suggested by a rising of the 125 I: 131 I ratio with time and by a 26% release of 131 I in the urine at 15 h which could not account for its plasma disappearance. Scanning, except for 131 I uptake in the spleen at 2 h likely due to blood activity, showed no organ concentration. 92% of the injected 131 I was found in the urine but only 6.2% of 131 I SAA was accounted for in urine precicipitates

  19. Sustained high serum caspase-3 concentrations and mortality in septic patients.

    Science.gov (United States)

    Lorente, L; Martín, M M; Pérez-Cejas, A; González-Rivero, A F; López, R O; Ferreres, J; Solé-Violán, J; Labarta, L; Díaz, C; Palmero, S; Jiménez, A

    2018-02-01

    Caspase-3 is the main executor of the apoptotic process. Higher serum caspase-3 concentrations in non-survivor compared to survivor septic patients have been found. The objectives of this work (with the increase of sample size to 308 patients, and the determination of serum caspase-3 concentrations also on days 4 and 8 of diagnosis of severe sepsis) were to know whether an association between serum caspase-3 concentrationss during the first week, degree of apoptosis, sepsis severity, and sepsis mortality exists. We collected serum samples of 308 patients with severe sepsis from eight intensive care units on days 1, 4 and 8 to measure concentrations of caspase-3 and caspase-cleaved cytokeratin (CCCK)-18 (to assess degree of apoptosis). End point was 30-day mortality. We found higher serum concentrations of caspase-3 and CCCK-18 in non-survivors compared to survivors on days 1 (p < 0.001), 4 (p < 0.001), and 8 (p < 0.001). We found an association between serum caspase-3 concentrations on days 1, 4 and 8 of severe sepsis diagnosis and serum CCCK-18 concentrations (p < 0.001), SOFA (p < 0.001), serum acid lactic concentrations (p < 0.001), and 30-day sepsis mortality (p < 0.001). The new findings of this work were that an association between serum caspase-3 concentrations during the first week, apoptosis degree, sepsis severity, and sepsis mortality exists.

  20. Serum Glutamate Is a Predictor for the Diagnosis of Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gheyath Al Gawwam

    2017-01-01

    Full Text Available One neurotransmitter, glutamate, has been implicated in the autoimmune demyelination seen in multiple sclerosis (MS. Glutamate is present in many tissues in the body, so consideration should be given to whether the serum level of glutamate is likely well correlated with the activity of the disease. This research aimed to compare the serum glutamate levels from patients diagnosed with MS with those from an age-matched control population. A review of this data could shed light upon whether the serum testing of glutamate using Enzyme-Linked Immunosorbent Assay (ELISA is a reliable indicator of MS activity. Serum samples were obtained from 55 patients with different patterns of MS and from 25 healthy adults as a control group. The ELISA technique was used to determine the glutamate levels in the serum samples. The mean serum glutamate level for patients with MS was 1.318±0.543 nmol/ml and that of the controls was 0.873±0.341 nmol/ml. The serum glutamate levels showed an area under the curve via the receiver operating characteristics (ROC of 0.738, which was significant (p value = 0.001. The present study is the first to establish a strong connection between the serum glutamate levels and MS patients, where there was statistically significant elevation of serum glutamate in MS patients; hence this elevation might be used as a monitor to help in the diagnosis of MS patients.

  1. Serum amyloid A isoforms in serum and synovial fluid from spontaneously diseased dogs with joint diseases or other conditions

    DEFF Research Database (Denmark)

    Kjelgaard-Hansen, Mads Jens; Christensen, Michelle B.; Lee, Marcel Huisung

    2007-01-01

    Serum amyloid A (SAA) is a major acute phase protein in dogs. However, knowledge of qualitative properties of canine SAA and extent of its synthesis in extrahepatic tissues is limited. The aim of the study was to investigate expression of different SAA isoforms in serum and synovial fluid...... in samples obtained from dogs (n = 16) suffering from different inflammatory or non-inflammatory conditions, which were either related or unrelated to joints. Expression of SAA isoforms was visualized by denaturing isoelectric focusing and Western blotting. Serum amyloid A was present in serum from all dogs...... with systemic inflammatory activity, and up to four major isoforms with apparent isoelectric points between 6.1 and 7.9 were identified. In synovial fluid from inflamed joints one or more highly alkaline SAA isoforms (with apparent isoelectric points above 9.3) were identified, with data suggesting local...

  2. Parathyroid hormone related protein concentration in human serum and CSF correlates with age.

    Science.gov (United States)

    Kushnir, Mark M; Peterson, Lisa K; Strathmann, Frederick G

    2018-02-01

    Parathyroid Hormone-Related Protein (PTHrP) is involved in intracellular calcium (Ca) regulation, and has been demonstrated to participate in regulation of Ca in brain cells, activation of neurons, and modulation of pain. However, there are conflicting reports regarding the presence of PTHrP in CSF. PTHrP and Ca were quantified in paired CSF and serum samples using mass spectrometry-based methods. Associations between PTHrP and Ca concentrations with age, sex and concentrations of nine CSF diagnostic markers in a set of 140 paired serum and CSF patient samples were evaluated. The observed median PTHrP concentration in CSF was 51 times higher than in serum; the median concentration of Ca in CSF was 1.8 times lower than in serum. We observed positive correlation between concentrations of PTHrP in CSF and serum (p=0.013). Distribution of PTHrP concentrations in serum was associated with age (p=0.0068) and the concentrations were higher in women. In samples with serum calcium concentrations within the reference intervals (n=118), central 95% distribution of concentrations for Ca-CSF, PTHrP-serum and PTHrP-CSF were 5.4 (4.5-6.1) mg/dL, 1.2 (0.5-2.5) pmol/L, 62 (22-125) pmol/L, respectively. Our data demonstrate that PTHrP is a normal constituent of human CSF with median concentrations 51 fold higher than in serum. Elevated serum PTHrP concentrations were positively correlated with age and significantly higher in women. Our data suggest that CSF could be a significant source of circulating PTHrP. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients

    OpenAIRE

    Venkatapathy, Ramesh; Govindarajan, Vasupradha; Oza, Nirima; Parameswaran, Sreejith; Pennagaram Dhanasekaran, Balamurali; Prashad, Karthikshree V.

    2014-01-01

    Context. Sampling blood for serum analysis is an invasive procedure. A noninvasive alternative would be beneficial to patients and health care professionals. Aim. To correlate serum and salivary creatinine levels and evaluate the role of saliva as a noninvasive alternative to serum for creatinine estimation in chronic kidney disease patients. Study Design. Case-control study. Methods. Blood and saliva samples were collected from 37 healthy individuals and 105 chronic kidney disease patients...

  4. Reliability of a method of sampling stream invertebrates

    CSIR Research Space (South Africa)

    Chutter, FM

    1966-05-01

    Full Text Available In field ecological studies inferences must often be drawn from dissimilarities in numbers and species of organisms found in biological samples collected at different times and under various conditions....

  5. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    Energy Technology Data Exchange (ETDEWEB)

    Pals, G; Meuwissen, S G.M.; Frants, R R; Kostense, P J; Eriksson, A W; Raesaenen, V

    1987-02-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 ..mu..g/l and r=0.971 in the range 0-100 ..mu..g/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum.

  6. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    International Nuclear Information System (INIS)

    Pals, Gerard; Meuwissen, S.G.M.; Frants, R.R.; Kostense, P.J.; Eriksson, A.W.; Raesaenen, Vesa

    1987-01-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 μg/l and r=0.971 in the range 0-100 μg/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum. (author)

  7. Structural Parameters and Strengthening Mechanisms in Cold-Drawn Pearlitic Steel Wires

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andy; Huang, Xiaoxu

    2012-01-01

    Pearlitic steel wires have a nanoscale structure and a strength which can reach 5 GPa. In order to investigate strengthening mechanisms, structural parameters including interlamellar spacing, dislocation density and cementite decomposition, have been analyzed by transmission electron microscopy...... and high resolution electron microscopy in wires cold drawn up to a strain of 3.7. Three strengthening mechanisms, namely boundary strengthening, dislocation strengthening and solid solution hardening have been analyzed and good agreement has been found between the measured flow stress and the value...

  8. Xeno-oestrogenic activity in serum as marker of occupational pesticide exposure

    DEFF Research Database (Denmark)

    Andersen, Helle Raun; Nielsen, Flemming; Nielsen, Jesper Bo

    2007-01-01

    -oestrogenic activity in serum was statistically significant for women who had been at work within the last week, while no association was observed for women who had not been at work during the most recent week. Conclusions: The study illustrates the usefulness of this biomarker for qualitative assessment...... with oestrogen-like properties in an occupational setting. Methods: Serum samples were obtained from two separate cohorts representing non-pregnant and pregnant female greenhouse workers in Denmark. Serum samples from 270 non-pregnant women and 173 pregnant women were analysed for xeno-oestrogenic activity......, medium or high based on information collected by detailed interviews of the women and the employers. Results: In both cohorts, an exposure-associated increase in the xeno-oestrogenic activity in serum was demonstrated. Among the pregnant women, the association between pesticide exposure and xeno...

  9. 75 FR 95 - Endorsement and Payment of Checks Drawn on the United States Treasury

    Science.gov (United States)

    2010-01-04

    ... Checks Drawn on the United States Treasury AGENCY: Financial Management Service, Fiscal Service, Treasury..., Financial Management Service (FMS), is proposing to amend its regulation governing the endorsement and... Banks to debit a financial institution's account at the financial institution's servicing Federal...

  10. 76 FR 57907 - Indorsement and Payment of Checks Drawn on the United States Treasury

    Science.gov (United States)

    2011-09-19

    ...), Financial Management Service (FMS), to direct Federal Reserve Banks to debit a financial institution's Master Account for all check reclamations against the financial institution that the financial... Checks Drawn on the United States Treasury AGENCY: Financial Management Service, Fiscal Service, Treasury...

  11. [Determination of serum acetaminophen based on the diazo reaction and its application in the evaluation of gastric emptying].

    Science.gov (United States)

    Li, Cai-na; Sun, Su-juan; Shen, Zhu-fang

    2015-05-01

    This study aims to establish a method to determine the serum acetaminophen concentration based on diazo reaction, and apply it in the gastric emptying evaluation. Theoretically, acetaminophen could take hydrolysis reaction in hydrochloric acid solution to produce p-aminophenol, which could then take diazo reaction resulting in a product with special absorption peak at 312 nm. Then the serum acetaminophen concentration and recovery rate were calculated according to the standard curve drawn with absorbance at 312 nm. ICR mice were given a dose of acetaminophen (500 mg x kg(-1)) by gavage and the serum acetaminophen was dynamically measured through the diazo reaction. Besides, ICR mice were subcutaneously injected with the long-acting GLP-1 analog GW002 before the gavage of acetaminophen, and serum acetaminophen concentration was measured as above to study how GW002 could influence the gastric emptying. The data showed acetaminophen ranging from 0 to 160 μg x mL(-1) could take diazo reaction with excellent linear relationship, and the regression equation was y = 0.0181 x +0.0104, R2 = 0.9997. The serum acetaminophen was also measured with good linear relationship (y = 0.0045 x + 0.0462, R = 0.9982) and the recovery rate was 97.4%-116.7%. The serum concentration of acetaminophen reached peak at about 0.5 h after gavage, and then gradually decreased. GW002 could significantly lower the serum acetaminophen concentration and make the area under the concentration-time curve (AUC) decrease by 28.4%. In conclusion, a method for the determination of serum acetaminophen based on the diazo reaction was established with good accuracy and could be used in the evaluation of gastric emptying.

  12. Alterations of serum cholesterol and serum lipoprotein in breast cancer of women

    OpenAIRE

    Hasija, Kiran; Bagga, Hardeep K.

    2005-01-01

    Fasting blood sample of 50 normal subjects (control) and 100 patients of breast cancer were investigated for serum total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol, very low density lipoprotein, high density lipoprotein cholesterol:low density lipoprotein cholesterol ratio and total cholesterol:high density lipoprotein cholesterol ratio during breast cancer of women. Five cancer stages, types, age groups, parity and menopausal status were undertaken...

  13. TEST OF AN ANIMAL DRAWN FIELD IMPLEMENT CART

    Directory of Open Access Journals (Sweden)

    Paolo Spugnoli

    2008-06-01

    Full Text Available The field performance of a horse-drawn hitch cart equipped with a PTO system powered by the two cart ground wheels have been investigated. For this purpose field tests on clay and turf soil, with varying ballast and PTO torque, have been carried out pulling the cart by a tractor. Preliminary tests were aimed at assessing the traction capability of horse breed. These tests showed that the mean draught force given by two of these horses was 173daN, average working speed was about 1m*s-1, resulting a mean draught power developed by each horse of about 0.86kW. The PTO cart system performance has shown that the torque has not exceeded 2.4daN*m, maximum draught or PTO power was 1.15kW, rotation speed just higher than 400min-1, with mean efficiency of about 50%. These values are consistent with horse performance and small haymaking, fertilizing, seeding and chemical application machine requirements.

  14. An analysis of the relationship between serum cortisol and serum sodium in routine clinical patients

    Directory of Open Access Journals (Sweden)

    Eleanor McLaughlan

    2017-08-01

    Full Text Available Objectives: Adrenal insufficiency is an uncommon cause of hyponatraemia that should not be overlooked due to the severe consequences of an Addisonian crisis. Using the laboratory database of a large teaching hospital, we have explored the relationship between serum sodium and serum cortisol, and have estimated the frequency of hypoadrenalism in severely hyponatraemic patients. Design and methods: Data were gathered over a 23 month period from the Laboratory Information Management System at the Leeds Teaching Hospitals NHS Trust for instances where serum sodium and cortisol had been measured on a single sample. Data were also gathered over the same time period for all patients with severe hyponatraemia (serum sodium ≤120 mmol/L in order to determine the frequency of cortisol requesting and the incidence of adrenal insufficiency. Results: Analysis of the data (n=3268 patients revealed a trend showing higher cortisol concentrations in patients who were severely hypo- or hypernatraemic. The median cortisol concentration for patients with sodium ≤110 mmol/L was 856 nmol/L, and there was a gradual decrease in cortisol over the sodium range ≤110–150 mmol/L (Rs =−0.323, p<0.0001. Patients with sodium ≥151 mmol/L had a median cortisol of 725 nmol/L. 42% of the 978 patients with serum sodium ≤120 mmol/L had serum cortisol measured within two weeks, of whom 1.7% were diagnosed with adrenal insufficiency. Conclusions: This dataset shows rising cortisol in response to hypo- or hypernatraemia, in keeping with the stress response to illness. The data show that adrenal insufficiency is a rare cause of hyponatraemia which may be overlooked. Keywords: Serum, Sodium, Cortisol, Adrenal insufficiency

  15. Precise determination of sodium in serum by simulated isotope dilution method of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yan Ying; Zhang Chuanbao; Zhao Haijian; Chen Wenxiang; Shen Ziyu; Wang Xiaoru; Chen Dengyun

    2007-01-01

    A new precise and accurate method for the determination of sodium in serum by inductively coupled plasma mass spectrometry (ICP-MS) was developed. Since 23 Na is the single isotope element, 27 Al is selected as simulated isotope of Na. Al is spiked into serum samples and Na standard solution. 23 Na/ 27 Al ratio in the Na standard solution is determined to assume the natural Na isotope ratio. The serums samples are digested by purified HNO 3 /H 2 O 2 and diluted to get about 0.6 μg·g -1 Al solutions, and the 23 Na/ 27 Al ratios of the serum samples are obtained to calculate the accurate Na concentrations basing on the isotope dilution method. When the simulated isotope dilution method of ICP-MS is applied and Al is selected as the simulated isotope of Na, the precise and accurate Na concentrations in the serums are determined. The inter-day precision of CV<0.13% for one same serum sample is obtained during 3 days 4 measurements. The spike recoveries are between 99.69% and 100.60% for 4 different serum samples and 3 days multi-measurements. The results of measuring standard reference materials of serum sodium are agree with the certified value. The relative difference between 3 days is 0.22%-0.65%, and the relative difference in one bottle is 0.15%-0.44%. The ICP-MS and Al simulated isotope dilution method is proved to be not only precise and accurate, but also quick and convenient for measuring Na in serum. It is promising to be a reference method for precise determination of Na in serum. Since Al is a low cost isotope dilution reagent, the method is possible to be widely applied for serum Na determination. (authors)

  16. Serum Metabonomics of Mild Acute Pancreatitis.

    Science.gov (United States)

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  17. Immunoreactive somatomedin A in human serum

    International Nuclear Information System (INIS)

    Hall, K.; Brandt, J.; Enberg, G.; Fryklund, L.

    1979-01-01

    A RIA has been developed for somatomedin A (SM-A) utilizing Sepharose-bound antibodies. This assay, measuring SM-A, the insulin-like growth factors 1 and 2, and somatomedin C, allows determination in serum samples. In comparison with a serum standard, the mean serum levels in patients with acromegaly or GH deficiency and healthy subjects were 8.7 +- 0.7 (n=25), 0.24 +- 0.02 (n=25), and 1.15 +- 0.11 U/ml, respectively. The correlation coefficient between immunoreactive SM-A and SM-A by radioreceptor assay was highly significant (r=0.93), although the potency ratio of SM-A between the two groups of patients was higher in the RIA than in the radioreceptor assay. Gel chromatography revealed that SM-A in acromegalic serum is bound to a carrier protein which is absent in patients with GH deficiency. After gel chromatography at low pH, 90% of applied immunoreactive SM-A was recovered in the low molecular weight fraction and consisted mainly of neutral polypeptides

  18. Epinephrine Auto-Injector Versus Drawn Up Epinephrine for Anaphylaxis Management: A Scoping Review.

    Science.gov (United States)

    Chime, Nnenna O; Riese, Victoria G; Scherzer, Daniel J; Perretta, Julianne S; McNamara, LeAnn; Rosen, Michael A; Hunt, Elizabeth A

    2017-08-01

    Anaphylaxis is a life-threatening event. Most clinical symptoms of anaphylaxis can be reversed by prompt intramuscular administration of epinephrine using an auto-injector or epinephrine drawn up in a syringe and delays and errors may be fatal. The aim of this scoping review is to identify and compare errors associated with use of epinephrine drawn up in a syringe versus epinephrine auto-injectors in order to assist hospitals as they choose which approach minimizes risk of adverse events for their patients. PubMed, Embase, CINAHL, Web of Science, and the Cochrane Library were searched using terms agreed to a priori. We reviewed human and simulation studies reporting errors associated with the use of epinephrine in anaphylaxis. There were multiple screening stages with evolving feedback. Each study was independently assessed by two reviewers for eligibility. Data were extracted using an instrument modeled from the Zaza et al instrument and grouped into themes. Three main themes were noted: 1) ergonomics, 2) dosing errors, and 3) errors due to route of administration. Significant knowledge gaps in the operation of epinephrine auto-injectors among healthcare providers, patients, and caregivers were identified. For epinephrine in a syringe, there were more frequent reports of incorrect dosing and erroneous IV administration with associated adverse cardiac events. For the epinephrine auto-injector, unintentional administration to the digit was an error reported on multiple occasions. This scoping review highlights knowledge gaps and a diverse set of errors regardless of the approach to epinephrine preparation during management of anaphylaxis. There are more potentially life-threatening errors reported for epinephrine drawn up in a syringe than with the auto-injectors. The impact of these knowledge gaps and potentially fatal errors on patient outcomes, cost, and quality of care is worthy of further investigation.

  19. Increased serum cortisol binding in chronic active hepatitis

    International Nuclear Information System (INIS)

    Orbach, O.; Schussler, G.C.

    1989-01-01

    A high serum cortisol concentration, apparently due to increased cortisol-binding globulin (CBG), was found in a patient (index case) with chronic active hepatitis (CAH). We therefore performed further studies to determine whether increased cortisol binding is generally associated with CAH. Serum samples were obtained from 15 hospitalized patients with long-term liver function test elevations but no evidence of cirrhosis, 15 normal subjects without a history of hepatitis, four healthy pregnant women, and 10 alcoholic patients with stigmata of cirrhosis. Serum cortisol binding was measured by an adaptation of a previously described charcoal uptake method. Thyroxine-binding globulin (TBG) and sex hormone-binding globulin were determined by radioimmunoassays. Charcoal uptake of 125I cortisol from sera of normal subjects and additional patients with CAH revealed that increased serum cortisol binding by a saturable site, presumably CBG, was associated with CAH. Cortisol binding was significantly correlated with immunoassayable TBG, suggesting that in CAH, similar mechanisms may be responsible for increasing the serum concentrations of CBG and TBG

  20. A novel radioassay for the determination of folate in serum and red cells and new observations on the stability of serum folate

    International Nuclear Information System (INIS)

    Lynch, E.P.J.; Tovey, K.C.; Guilford, H.

    1977-01-01

    A Competitive Protein Binding assay for the determination of folate in serum and red cells has been developed. The assay has been fully validated in hospital trials and comparisons have been made with the microbiological assay. We have based the standardization of the radioassay on N 5 -methyltetrahydrofolate (N 5 -MTHF) as this is the predominant folate derivative in serum samples. At about pH 9.5 pteroylglutamic acid (PGA) and N 5 -MTHF demonstrate the same affinity for folate binding proteins. Therefore, many folate assays have adopted PGA largely because of the popular belief that N 5 -MTHF is highly unstable. However, we have demonstrated that N 5 -MTHF in serum standards is surprisingly stable at -20 0 C. All the reagents for the assay (including the N 5 -MTHF standards) have shown perfectly acceptable stability, permitting their storage for at least three weeks at -20 0 C and one week at 4 0 C. Evidence will be presented to support the use of N 5 -MTHF as being the more appropriate standard. Folate in human serum samples is stable even at room temperature in the presence of 0.1% sodium azide. (orig./AJ) [de

  1. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  2. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  3. Efficient evaluation of humoral immune responses by the use of serum pools

    DEFF Research Database (Denmark)

    Sternbæk, Louise; Draborg, Anette H.; Nielsen, Christoffer T.

    2017-01-01

    has considered using serum pools as a quick and efficient screening method to confirm or deny hypotheses. Methods We created serum pools from four different patient groups (systemic lupus erythematosus n = 85, rheumatoid arthritis n = 77, Sjögren's syndrome n = 91, systemic sclerosis n = 66) and one......Background Collection and testing of individual serum samples are often used in research to gain knowledge about e.g. the humoral response against bacteria or virus. This is a valid but time-consuming method and might be a waste of valuable serum samples for inefficient research. So far, no study...... healthy control group (n = 67). Each serum pool was analyzed using three well-known immunoassays: enzyme-linked immunosorbent assay (ELISA), line blot, and immunofluorescence microscopy (anti-nuclear antibody (ANA) screening). The presence of Epstein-Barr virus (EBV) EA/D-, EBNA-1-, VCA p23-, and gp350...

  4. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  5. Serum protein fingerprint of patients with gastric cancer by SELDI ...

    African Journals Online (AJOL)

    To study the serum protein fingerprint of patients with gastric cancer and to screen for protein molecules closely related to gastric cancer during the onset and progression of the disease using surface-enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Serum samples from 80 gastric ...

  6. Analytical Application of Flow Immunosensor in Detection of Thyroxine and Triiodothyronine in Serum.

    Science.gov (United States)

    Wani, Tanveer A; Zargar, Seema; Majid, Salma; Darwish, Ibrahim A

    2016-11-01

    In this study, an immunosensor based on kinetic exclusion analysis (KinExA) was used for thyroxine (T4) and triiodothyronine (T3) estimation. A KinExA™ 3200 instrument was used for this analysis, which is an automated flow fluorimeter designed to separate free unbound antibody binding sites in reaction mixtures of antibody, antigen, and antibody-antigen complex. A T3-BSA- and T4-BSA-coated polymethyl methacrylate (PMMA) bead microcolumn is generated inside the flow cell of the instrument. A sample mixture containing T3 and T4 with their respective monoclonal antibodies and their complexes are drawn past the microbead column. The unbound T3 or T4 monoclonal antibody binding sites are captured by their respective T3 and T4 antigens coated on the PMMA beads as bovine serum albumin conjugates. Fluorescently labeled secondary antibodies bind to the T3 or T4 antigen-antibody complex to generate fluorescence intensity for analysis. The limit of detection for the T3 and T4 assays was found to be 0.06 and 1.9 ng mL -1 with acceptable precision values. The convenience of the automated KinExA format may be valuable in medical diagnostic laboratories.

  7. Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Attia, M.S., E-mail: Mohamed_sam@yahoo.com [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); Othman, A.M. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt); Youssef, A.O. [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); El-Raghi, E. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt)

    2012-08-15

    This paper reports on a facile technique combined with a simple, sensitive and selective spectrofluorimetric method for the determination of hydrochlorothiazide. In methanol, at pH 8.3 and {lambda}{sub ex}=340, hydrochlorothiazide can remarkably enhance the luminescence intensity of the Eu{sup 3+} ion doped in polymethylmethacrylate polymer (PMMA) matrix. This could be due to the energy transfer from hydrochlorothiazide to Eu{sup 3+} in the excited stated. At the optimized experimental conditions, the enhancement of the characteristic emission band (617 nm) of Eu{sup 3+} ion doped PMMA is directly proportional to the concentration of hydrochlorothiazide with a dynamic range of 5 Multiplication-Sign 10{sup -8}-1.0 Multiplication-Sign 10{sup -5} mol L{sup -1} and detection limit of 8.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. Application of the suggested method was successfully applied to the determination of hydrochlorothiazide in pharmaceutical preparations and human serum samples, with high percentage of recovery, good accuracy and precision. - Highlights: Black-Right-Pointing-Pointer HCT was determined by europium sensitized by HCT in PMMA polymer. Black-Right-Pointing-Pointer Band at 617 nm of Eu{sup 3+} ion ({sup 5}D{sub 0}{yields}{sup 7}F{sub 2}) is sensitive to HCT concentration. Black-Right-Pointing-Pointer Recovery and R.S.D for tablets serum samples in proposed method were calculated. Black-Right-Pointing-Pointer Method is verified for HCT determination in real samples with no interferences.

  8. Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction-Measurement by ELISA.

    Directory of Open Access Journals (Sweden)

    Shozo Yokoyama

    Full Text Available Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA.One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH. Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay.A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference and the addition of bovine serum albumin (BSA resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA.We optimized an easy and rapid detection method for assessment of

  9. Airborne Precursors Predict Maternal Serum Perfluoroalkyl Acid Concentrations.

    Science.gov (United States)

    Makey, Colleen M; Webster, Thomas F; Martin, Jonathan W; Shoeib, Mahiba; Harner, Tom; Dix-Cooper, Linda; Webster, Glenys M

    2017-07-05

    Human exposure to persistent perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorooctanesulfonate (PFOS), can occur directly from contaminated food, water, air, and dust. However, precursors to PFAAs (PreFAAs), such as dipolyfluoroalkyl phosphates (diPAPs), fluorotelomer alcohols (FTOHs), perfluorooctyl sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs), which can be biotransformed to PFAAs, may also be a source of exposure. PFAAs were analyzed in 50 maternal sera samples collected in 2007-2008 from participants in Vancouver, Canada, while PFAAs and PreFAAs were measured in matching samples of residential bedroom air collected by passive sampler and in sieved vacuum dust (<150 μm). Concentrations of PreFAAs were higher than for PFAAs in air and dust. Positive associations were discovered between airborne 10:2 FTOH and serum PFOA and PFNA and between airborne MeFOSE and serum PFOS. On average, serum PFOS concentrations were 2.3 ng/mL (95%CI: 0.40, 4.3) higher in participants with airborne MeFOSE concentrations in the highest tertile relative to the lowest tertile. Among all PFAAs, only PFNA in air and vacuum dust predicted serum PFNA. Results suggest that airborne PFAA precursors were a source of PFOA, PFNA, and PFOS exposure in this population.

  10. Common lessons drawn from different laboratories analyses of super-phenix start-up experiments

    International Nuclear Information System (INIS)

    Cabrillat, J.C.; Salvatores, M.; Carta, M.; D'Angelo, A.; Giese, H.; De Wouters, R.; Newton, T.; Harrison, P.; Sztark, H.; Wehmann, U.

    1990-01-01

    Measurements issued from the SUPER-PHENIX start-up experiments have been analysed by the different partners within the European Community with their own data and methods. Common lessons can be drawn from the different analyses and recommendations made on the definition of the characteristics of a common European formulaire and in the actions in support of its qualification

  11. Genotyping of Single Nucleotide Polymorphisms in DNA Isolated from Serum Using Sequenom MassARRAY Technology.

    Directory of Open Access Journals (Sweden)

    Tess V Clendenen

    Full Text Available Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA.We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison.We observed that 60 of the 81 SNPs (74% had high call frequencies (≥95% using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95% had highly concordant (>98% genotype calls across all three sample types. High purity was not a critical factor to successful genotyping.Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.

  12. Automated measurement of serum thyroxine with the ''AIRA II,'' as compared with competitive protein binding and radioimmunoassay

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.V.R.

    1978-01-01

    Two conventional serum thyroxine assays, run in separate laboratories, one by competitive protein binding and one by radioimmunoassay, were used to evaluate the automated ARIA II (Becton Dickinson Immunodiagnostics) serum thyroxine assay. Competitive protein binding as compared to ARIA II with 111 clinical serum samples gave a slope of 1.04 and a correlation coefficient of 0.94. The radioimmunoassay comparison to ARIA II with 53 clinical serum samples gave a slope of 1.05 and a correlation coefficient of 0.92. The ARIA II inter-assay coefficient of variation for 10 replicates of low, medium, and high thyroxine serum samples was 6.2, 6.0, and 2.9%, respectively, with an inter-assay coefficient of variation among 15 different assays of 15.5, 10.1, and 7.9%. The automated ARIA II, with a 2.2-min cycle per sample, gives results that compare well with those by manual methodology

  13. Organohalogenated contaminants (OHCs) in the serum and hair of pet cats and dogs: Biosentinels of indoor pollution

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Nadeem [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Malik, Riffat Naseem [Environmental Biology and Ecotoxicology Laboratory, Department of Environmental Sciences, Quiad-i-Azam University, Islamabad 45320 (Pakistan); Mehdi, Toufeer [Institute of Microbiology, University of Agriculture Faisalabad (Pakistan); Eqani, Syed Ali Musstjab Akber Shah [Department of Bio Sciences, COMSATS Institute of Information Technology, Islamabad (Pakistan); Javeed, Aqeel [Department of Pharmacology and Toxicology, University of Veterinary and Animal Sciences, Lahore (Pakistan); Neels, Hugo [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Covaci, Adrian, E-mail: adrian.covaci@ua.ac.be [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium)

    2013-04-01

    Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p′-DDE, was the major OHC in cat serum (N = 20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p′-DDE was not detected in dog serum (N = 16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median = 6.0 ng/g lw) than cat serum (median = 2.2 ng/g lw). Levels of most OHCs were significantly higher (p < 0.05) in cat serum than those found in human serum from the same region, in particular for ∑PBDEs (ranged 1–1280 ng/g lw). Significantly lower levels of OCPs (p < 0.05) were detected in dog serum than in human serum. The concentrations of ∑BPs were seven times higher in cat serum (median 112 ng/g lw) than dog serum (median 16 ng/g lw). To the best of our knowledge, this is the first time that NBFRs, e.g. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenylethane (DBDPE), and bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), were detected in cat and dog's hair. BTBPE had the highest detection frequency (30%) in the serum samples. In cat and dog hair samples, the order of importance of OHCs was ∑OCPs > ∑NBFRs > ∑PBDEs > ∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N = 12), ∑DDTs (r = 0.65, p = 0.001) were significantly correlated, while for all other OHCs no significant correlations (p < 0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to

  14. Serum cation profile of broilers at various stages of exposure to deoxynivalenol.

    Science.gov (United States)

    Yunus, Agha Waqar; Böhm, Josef

    2013-05-01

    The present experiment was carried out to investigate if levels of serum cations in broilers are modulated differently at various stages of exposure to deoxynivalenol (DON). Male broiler chicks at 7 days of age were fed a basal diet (0.27 mg of DON; 0.01 mg of zearalenone/kg), or either a low DON diet (1.68 mg of DON; 0.15 mg of zearalenone/kg) or a high DON diet (12.21 mg of DON; 1.09 mg of zearalenone/kg) produced using extracts from Fusarium graminearum cultures. Blood samples from the birds were collected during weeks 2, 4, and 5 of exposure. The high DON diet resulted in lower serum calcium levels compared to the basal diet at all the 3 sampling stages, while the low DON diet resulted in lower serum calcium levels only during weeks 2 and 5. Serum potassium levels were reduced under both the DON diets during weeks 2 and 5, while no diet-associated changes were found for serum levels of magnesium, sodium, and zinc. Under the present experimental conditions, the serum levels of calcium were consistently modulated in the broilers exposed to the DON-contaminated diets. The modulation of serum levels of potassium was, however, dependent upon the stage of exposure to DON.

  15. Detection of Cytomegalovirus DNA in Serum Correlates with Clinical Cytomegalovirus Retinitis in AIDS

    DEFF Research Database (Denmark)

    Hansen, K.K.; Ricksten, A.; Hofmann, B.

    1994-01-01

    The high sensitivity of nested polymerase chain reaction (PCR) offers the possibility of rapid detection of cytomegalovirus (CMV) DNA in serum. Five consecutive serum samples were examined from 52 human immunodeficiency virus (HIV)-seropositive patients (19 of whom had clinically presumed diagnosis...... became positive with the onset of clinical retinitis. In contrast, 29 of 33 HIV-seropositive subjects without clinical CMV chorioretinitis and matched with respect to age and CD4 T cell numbers were negative for CMV DNA in all 5 serum samples. Thus, the presence of CMV DNA in serum analyzed by PCR...... is a good predictive marker of CMV retinitis in HIV-seropositive subjects. A positive PCR results supports the clinical diagnosis and may be useful for monitoring response to antiviral treatment....

  16. Supercritical fluid extraction of selected pharmaceuticals from water and serum.

    Science.gov (United States)

    Simmons, B R; Stewart, J T

    1997-01-24

    Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45 degrees C, and a restrictor temperature of 60 degrees C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n = 3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n = 3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n = 3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.

  17. Serum biomarkers for the early diagnosis of TIA: The MIND-TIA study protocol.

    Science.gov (United States)

    Dolmans, L Servaas; Rutten, Frans H; El Bartelink, Marie-Louise; Seppenwoolde, Gerdien; van Delft, Sanne; Kappelle, L Jaap; Hoes, Arno W

    2015-07-28

    A Transient Ischaemic Attack (TIA) bears a high risk of a subsequent ischaemic stroke. Adequate diagnosis of a TIA should be followed immediately by the start of appropriate preventive therapy, including antiplatelets. The diagnosis of a TIA based on symptoms and signs only is notoriously difficult and biomarkers of brain ischaemia might improve the recognition, and target management and prognosis of TIA patients. Our aim is to quantify the added diagnostic value of serum biomarkers of brain ischaemia in patients suspected of TIA. a cross-sectional diagnostic accuracy study with an additional six month follow-up period. 350 patients suspected of TIA in the primary care setting. Patients suspected of a TIA will be recruited by at least 200 general practitioners (GPs) in the catchment area of seven TIA outpatient clinics willing to participate in the study. In all patients a blood sample will be drawn as soon as possible after the patient has contacted the GP, but at least within 72 h after onset of symptoms. Participants will be referred by the GP to the regional TIA outpatient clinic for additional investigations, including brain imaging. The 'definite' diagnosis (reference standard) will be made by a panel consisting of three experienced neurologists who will use all available diagnostic information and the clinical information obtained during the outpatient clinic assessment, and a six month follow-up period. The diagnostic accuracy, and value in addition to signs and symptoms of candidate serum biomarkers will be assessed in terms of discrimination with C statistics, and calibration with plots. We aim to include 350 suspected cases, with 250 patients with indeed definite TIA (or minor stroke) according to the panel. We hope to find novel biomarkers that will enable a rapid and accurate diagnosis of TIA. This would largely improve the management and prognosis of such patients. ClinicalTrials.gov Identifier NCT01954329.

  18. Serum ferritin levels, socio-demographic factors and desferrioxamine therapy in multi-transfused thalassemia major patients at a government tertiary care hospital of Karachi, Pakistan

    Directory of Open Access Journals (Sweden)

    Rehman Anis

    2011-08-01

    Full Text Available Abstract Background Beta thalassemia is the most frequent genetic disorder of haemoglobin synthesis in Pakistan. Recurrent transfusions lead to iron-overload manifested by increased serum Ferritin levels, for which chelation therapy is required. Findings The study was conducted in the Pediatric Emergency unit of Civil Hospital Karachi after ethical approval by the Institutional Review Board of Dow University of Health Sciences. Seventy nine cases of beta thalassemia major were included after a written consent. The care takers were interviewed for the socio-demographic variables and the use of Desferrioxamine therapy, after which a blood sample was drawn to assess the serum Ferritin level. SPSS 15.0 was employed for data entry and analysis. Of the seventy-nine patients included in the study, 46 (58.2% were males while 33 (41.8% were females. The mean age was 10.8 (± 4.5 years with the dominant age group (46.2% being 10 to 14 years. In 62 (78.8% cases, the care taker education was below the tenth grade. The mean serum Ferritin level in our study were 4236.5 ng/ml and showed a directly proportional relationship with age. Desferrioxamine was used by patients in 46 (58.2% cases with monthly house hold income significant factor to the use of therapy. Conclusions The mean serum Ferritin levels are approximately ten times higher than the normal recommended levels for normal individuals, with two-fifths of the patients not receiving iron chelation therapy at all. Use of iron chelation therapy and titrating the dose according to the need can significantly lower the iron load reducing the risk of iron-overload related complications leading to a better quality of life and improving survival in Pakistani beta thalassemia major patients. Conflicts of Interest: None

  19. The fire course and consequences to be drawn from the fire in the Browns Ferry nuclear power station

    International Nuclear Information System (INIS)

    Hoffmeister, N.

    1977-01-01

    After a short description of the fire course and the fire fighting measures during the cable fire at Browns Ferry nuclear power station, the effects on the safety system are given in chronological order, and consequences are drawn for a general fire protection programme for nuclear power plants. In this context, the licensing guideline of the NRC for fire protection in nuclear power plants is mentioned, which took particular account of the consequences to be drawn from the Browns Ferry fire. (ORU) [de

  20. 7 CFR 27.35 - Lower class of two samples to prevail.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Lower class of two samples to prevail. 27.35 Section 27.35 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE... Micronaire Determinations § 27.35 Lower class of two samples to prevail. In case a sample drawn from one...

  1. Application of FT-IR spectroscopy on breast cancer serum analysis

    Science.gov (United States)

    Elmi, Fatemeh; Movaghar, Afshin Fayyaz; Elmi, Maryam Mitra; Alinezhad, Heshmatollah; Nikbakhsh, Novin

    2017-12-01

    Breast cancer is regarded as the most malignant tumor among women throughout the world. Therefore, early detection and proper diagnostic methods have been known to help save women's lives. Fourier Transform Infrared (FT-IR) spectroscopy, coupled with PCA-LDA analysis, is a new technique to investigate the characteristics of serum in breast cancer. In this study, 43 breast cancer and 43 healthy serum samples were collected, and the FT-IR spectra were recorded for each one. Then, PCA analysis and linear discriminant analysis (LDA) were used to analyze the spectral data. The results showed that there were differences between the spectra of the two groups. Discriminating wavenumbers were associated with several spectral differences over the 950-1200 cm- 1(sugar), 1190-1350 cm- 1 (collagen), 1475-1710 cm- 1 (protein), 1710-1760 cm- 1 (ester), 2800-3000 cm- 1 (stretching motions of -CH2 & -CH3), and 3090-3700 cm- 1 (NH stretching) regions. PCA-LDA performance on serum IR could recognize changes between the control and the breast cancer cases. The diagnostic accuracy, sensitivity, and specificity of PCA-LDA analysis for 3000-3600 cm- 1 (NH stretching) were found to be 83%, 84%, 74% for the control and 80%, 76%, 72% for the breast cancer cases, respectively. The results showed that the major spectral differences between the two groups were related to the differences in protein conformation in serum samples. It can be concluded that FT-IR spectroscopy, together with multivariate data analysis, is able to discriminate between breast cancer and healthy serum samples.

  2. Comparison of serum pools and oral fluid samples for detection of porcine circovirus type 2 by quantitative real-time PCR in finisher pigs

    DEFF Research Database (Denmark)

    Nielsen, Gitte Blach; Nielsen, Jens Peter; Haugegaard, John

    2018-01-01

    Porcine circovirus type 2 (PCV2) diagnostics in live pigs often involves pooled serum and/or oral fluid samples for group-level determination of viral load by quantitative real-time polymerase chain reaction (qPCR). The purpose of the study was to compare the PCV2 viral load determined by q......PCR of paired samples at the pen level of pools of sera (SP) from 4 to 5 pigs and the collective oral fluid (OF) from around 30 pigs corresponding to one rope put in the same pen. Pigs in pens of 2 finishing herds were sampled by cross-sectional (Herd 1) and cross-sectional with follow-up (Herd 2) study designs....... In Herd 1, 50 sample pairs consisting of SP from 4 to 5 pigs and OF from around 23 pigs were collected. In Herd 2, 65 sample pairs consisting of 4 (SP) and around 30 (OF) pigs were collected 4 times at 3-week intervals. A higher proportion of PCV2-positive pens (86% vs. 80% and 100% vs. 91%) and higher...

  3. Proteomics Analysis for Finding Serum Markers of Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Yushan Cheng

    2014-01-01

    Full Text Available A combination of peptide ligand library beads (PLLB and 1D gel liquid chromatography-mass spectrometry/mass spectrometry (1DGel-LC-MS/MS was employed to analyze serum samples from patients with ovarian cancer and from healthy controls. Proteomic analysis identified 1200 serum proteins, among which 57 proteins were upregulated and 10 were downregulated in the sera from cancer patients. Retinol binding protein 4 (RBP4 is highly upregulated in the ovarian cancer serum samples. ELISA was employed to measure plasma concentrations of RBP4 in 80 samples from ovarian cancer patients, healthy individuals, myoma patients, and patients with benign ovarian tumor, respectively. The plasma concentrations of RBP4 ranging from 76.91 to 120.08 ng/mL with the mean value 89.13±1.67 ng/mL in ovarian cancer patients are significantly higher than those in healthy individuals (10.85±2.38 ng/mL. Results were further confirmed with immunohistochemistry, demonstrating that RBP4 expression levels in normal ovarian tissue were lower than those in ovarian cancer tissues. Our results suggested that RBP4 is a potential biomarker for diagnostic of screening ovarian cancer.

  4. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  5. Research on Melt Degassing Processes of High Conductivity Hard Drawn Aluminum Wire

    Science.gov (United States)

    Xu, Xuexia; Feng, Yanting; Wang, Qing; Li, Wenbin; Fan, Hui; Wang, Yong; Li, Guowei; Zhang, Daoqian

    2018-03-01

    Degassing effects of ultrasonic and vacuum processes on high conductivity hard drawn aluminum melt were studied. Results showed that the degassing efficiency improved with the increase of ultrasonic power within certain range, stabilizing at 70% with 240W. For vacuum degassing process, hydrogen content of aluminum melt decreased with the loading time and was linear with logarithm of vacuum degree. Comparison of degassing effects of ultrasonic, vacuum, vacuum-ultrasonic degassing process showed that vacuum-ultrasonic process presented optimal effect.

  6. Serum endocan levels before and after surgery on low-grade gliomas.

    Science.gov (United States)

    Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda

    2017-01-01

    Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.

  7. determination of serum chloride ion concentration in pregnant

    African Journals Online (AJOL)

    Yusif

    ABSTRACT. Serum chloride ion level in blood samples of pregnant women attending ante-natal care clinic in Minjibir was investigated. The mean and standard deviation of the ion in the samples is 100.51+ 4.89mmol/L. The distribution is skewed towards high frequency of low concentrations and could be attributed to.

  8. Plasma and Serum Metabolite Association Networks: Comparability within and between Studies Using NMR and MS Profiling.

    Science.gov (United States)

    Suarez-Diez, Maria; Adam, Jonathan; Adamski, Jerzy; Chasapi, Styliani A; Luchinat, Claudio; Peters, Annette; Prehn, Cornelia; Santucci, Claudio; Spyridonidis, Alexandros; Spyroulias, Georgios A; Tenori, Leonardo; Wang-Sattler, Rui; Saccenti, Edoardo

    2017-07-07

    Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA-MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids.

  9. Tensile behaviour of drawn tungsten wire used in tungsten fibre-reinforced tungsten composites

    International Nuclear Information System (INIS)

    Riesch, J; Feichtmayer, A; Fuhr, M; Gietl, H; Höschen, T; Neu, R; Almanstötter, J; Coenen, J W; Linsmeier, Ch

    2017-01-01

    In tungsten fibre-reinforced tungsten composites (W f /W) the brittleness problem of tungsten is solved by utilizing extrinsic toughening mechanisms. The properties of the composite are very much related to the properties of the drawn tungsten wire used as fibre reinforcements. Its high strength and capability of ductile deformation are ideal properties facilitating toughening of W f /W. Tensile tests have been used for determining mechanical properties and study the deformation and the fracture behaviour of the wire. Tests of as-fabricated and straightened drawn wires with a diameter between 16 and 150 μ m as well as wire electrochemically thinned to a diameter of 5 μ m have been performed. Engineering stress–strain curves and a microscopic analysis are presented with the focus on the ultimate strength. All fibres show a comparable stress–strain behaviour comprising necking followed by a ductile fracture. A reduction of the diameter by drawing leads to an increase of strength up to 4500 MPa as a consequence of a grain boundary hardening mechanism. Heat treatment during straightening decreases the strength whereas electrochemical thinning has no significant impact on the mechanical behaviour. (paper)

  10. Validity of transcobalamin II-based radioassay for the determination of serum vitamin B12 concentrations

    International Nuclear Information System (INIS)

    Paltridge, G.; Rudzki, Z.; Ryall, R.G.

    1980-01-01

    A valid radioassay for the estimation of serum vitamin B 12 in the presence of naturally occurring vitamin B 12 (= cobalamin) analogues can be operated if serum transcobalamin II (TC II) is used as the binding protein. Serum samples that gave diagnostically discrepant results when their vitamin B 12 content was analysed (i) by a commercial radioassay known to be susceptible to interference from cobalamin analogues, and (ii) by microbiological assay, were further analysed by an alternative radioassay which uses the transcobalamins (principally TC II) of diluted normal serum as the assay binding protein. Concordance between the results from microbiological assay and the TC II-based radioassay was found in all cases. In an extended study over a three-year period, all routine serum samples sent for vitamin B 12 analysis that had a vitamin B 12 content of less than 320 ng/l by the TC II-based radioassay (reference range 200-850 ng/l) were reanalysed using an established microbiological method. Over 1000 samples were thus analysed. The data are presented to demonstrate the validity of the TC II-based radioassay results in this group of patients, serum samples from which are most likely to produce diagnostically erroneous vitamin B 12 results when analysed by a radioassay that is less specific for cobalamins. (author)

  11. Cardiac troponin T and CK-MB mass release after visually successful percutaneous transluminal coronary angioplasty in stable angina pectoris

    DEFF Research Database (Denmark)

    Ravkilde, J; Nissen, H; Mickley, H

    1994-01-01

    The incidence of cardiac troponin T (Tn-T) and creatine kinase (CK) isoenzyme MB mass release was studied in 23 patients with stable angina pectoris undergoing visually successful percutaneous transluminal coronary angioplasty (PTCA). Serial blood samples were drawn for measurement of serum Tn...

  12. Analysis of serum angiotensin-converting enzyme.

    Science.gov (United States)

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  13. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples.

    Science.gov (United States)

    Yilmaz, Erkan; Ocsoy, Ismail; Ozdemir, Nalan; Soylak, Mustafa

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L(-)(1) and 8.8 μg L(-)(1), respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. A computational platform for MALDI-TOF mass spectrometry data: application to serum and plasma samples.

    Science.gov (United States)

    Mantini, Dante; Petrucci, Francesca; Pieragostino, Damiana; Del Boccio, Piero; Sacchetta, Paolo; Candiano, Giovanni; Ghiggeri, Gian Marco; Lugaresi, Alessandra; Federici, Giorgio; Di Ilio, Carmine; Urbani, Andrea

    2010-01-03

    Mass spectrometry (MS) is becoming the gold standard for biomarker discovery. Several MS-based bioinformatics methods have been proposed for this application, but the divergence of the findings by different research groups on the same MS data suggests that the definition of a reliable method has not been achieved yet. In this work, we propose an integrated software platform, MASCAP, intended for comparative biomarker detection from MALDI-TOF MS data. MASCAP integrates denoising and feature extraction algorithms, which have already shown to provide consistent peaks across mass spectra; furthermore, it relies on statistical analysis and graphical tools to compare the results between groups. The effectiveness in mass spectrum processing is demonstrated using MALDI-TOF data, as well as SELDI-TOF data. The usefulness in detecting potential protein biomarkers is shown comparing MALDI-TOF mass spectra collected from serum and plasma samples belonging to the same clinical population. The analysis approach implemented in MASCAP may simplify biomarker detection, by assisting the recognition of proteomic expression signatures of the disease. A MATLAB implementation of the software and the data used for its validation are available at http://www.unich.it/proteomica/bioinf. (c) 2009 Elsevier B.V. All rights reserved.

  15. Serum LP(A) levels in randomized healthy men from different European countries

    NARCIS (Netherlands)

    Cigolini, M; Seidell, J C; Zenti, M G; Bonadonna, G; Zambelli, L; Deslypere, J P; Contaldo, F; Cruz, A.; Charzewska, J; Targher, G

    Serum lipoprotein(a) [Lp(a)], blood lipids, serum insulin and anthropometric parameters were determined in randomized samples of 38-year-old men living in six European cities: Ede (The Netherlands), Deinze (Belgium), Warsaw (Poland), Lumiar (Portugal), Verona and Naples (respectively in northern and

  16. Comparative evaluation of various solid phases for the development of coated tube assays for the estimation of progesterone in human serum, bovine serum and bovine milk

    International Nuclear Information System (INIS)

    Karir, Tarveen; Samuel, Grace; Sivaprasad, N.; Venkatesh, Meera

    2009-01-01

    Immobilization of progesterone antibody using three polystyrene surfaces and two progesterone radiotracers for use in the development of a coated tube assay for the evaluation of progesterone levels in human serum, bovine serum and bovine milk was studied. The selection of the solid phase and the tracers were based on the maximum binding, non-specific binding, sensitivity and percentage recovery. Amongst the polystyrene tubes studied, streptavidin coated tubes showed the acceptable assay features such as low non-specific binding (0.5-1.0%), adequate sensitivity (0.13-0.16 ng/ml) and recovery (85-115%) for all the three sample matrices, human serum, bovine serum and bovine milk.

  17. Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.

    Science.gov (United States)

    Mozaffari, A A; Samadieh, H

    2013-09-01

    To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.

  18. Serum homocysteine level in vegetarians in District Tharparker, Sindh

    Science.gov (United States)

    Kapoor, Aneel; Zuberi, Nudrat Anwar; Rathore, M. Imran; Baig, Mukhtiar

    2015-01-01

    Objectives: The aim of present study was to investigate serum homocysteine levels in apparently healthy vegetarians and ominvores in Mithi, district Tharparker, Sindh, Pakistan. Methods: This study was conducted in the Department of Biochemistry, Basic Medical Sciences Institute (BMSI), Jinnah Postgraduate Medical Center (JPMC), Karachi and blood samples were collected from Mithi, district Tharparker, Sindh, Pakistan, in 2012. One hundred vegetarian and one hundred omnivores (age ranging from 20-40 years) were enrolled for this study. Serum homocysteine levels were measured by the chemiluminescence enzyme immunoassay method. Results: Serum homocysteine (Hcy) level was considerably higher (p15µmol/L compared to omnivores 6%, (p15µmol/L serum Hcy level in vegetarian group and 6.9% male and 3.5% females had >15µmol/L serum Hcy level in omnivores group, but the difference was not significant in any group. Conclusion: Vegetarians are more prone to develop hyperhomocysteinemia, so they are at high risk to develop cardiovascular disease. PMID:25878628

  19. Lessons drawn from the operation of EDF 900MW nuclear power plants to evaluate and improve safety

    International Nuclear Information System (INIS)

    Brisbois, J.; Dupuis, M.C.; Marcille, R.

    1986-06-01

    The lessons drawn from operation are used to detect the weak points not taken sufficiently into account by the design studies and to check that system availability remains at least equal to the level defined at the design stage. In both cases, they aim at deciding what remedial actions are to be taken. The latter may result in additional obligations (modification or addition of equipment or operating rules) and, in certain cases, may slacken obligations. This paper examines in turn: how are the events recorded and then analyzed, what lessons are drawn using concrete examples, what contribution is made by probabilistic risk studies using experience feedback in evaluating overall safety [fr

  20. Stability of selected serum hormones and lipids after long-term storage in the Janus Serum Bank.

    Science.gov (United States)

    Gislefoss, Randi E; Grimsrud, Tom K; Mørkrid, Lars

    2015-04-01

    The potential value of a biobank depends on the quality of the samples, i.e. how well they reflect the biological or biochemical state of the donors at the time of sampling. Documentation of sample quality has become a particularly important issue for researchers and users of biobank studies. The aim of this study was to investigate the long-term stability of selected components: cholesterol, high density cholesterol (HDLC), low density cholesterol (LDLC), apolipoprotein A1 (apo-A1), apolipoprotein B (apo B), follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), thyroid stimulating hormone (TSH) and free thyroxin (FT4). Samples, stored at -25°C, from 520 men aged 40-49 years at blood sampling distributed in equally sized groups (n=130) according to length of storage, 0, 4, 17 and 29 years, respectively, were used in a cross sectional design. The freshly collected serum samples were used as a reference group to calculate storage related changes. The differences between fresh samples and samples stored for 29 years were substantial for apo-A1 (+12%), apo-B (+22.3%), HDLC (-69.2%), LDLC (+31.3%), and PRL (-33.5%), while total cholesterol, FSH, LH, TSH and FT4 did not show any significant difference. The study showed large differences in serum level of the selected components. The lipids and apolipoproteins were all changed except for total cholesterol. Most hormones investigated (FSH, LH, TSH and FT4) proved to be stable after 29 years of storage while PRL showed sign of degradation. The observed differences are probably due to long-term storage effects and/or external factors (i.e. diet and smoking). Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. 78 FR 21596 - Drawn Stainless Steel Sinks From the People's Republic of China: Countervailing Duty Order

    Science.gov (United States)

    2013-04-11

    ... single or multiple drawn bowls, with or without drain boards, whether finished or unfinished, regardless... steel, and then welding and finishing the vertical corners to form the bowls. Stainless steel sinks with...

  2. The effect of aqueous Aloe vera gel extract on serum mineral ...

    African Journals Online (AJOL)

    This study was conducted to determine the effect of Aloe vera gel extract on the serum mineral compositions of Red Sokoto bucks. Blood samples were collected from 30 bucks before the commencement of administration of Aloe vera gel extract for serum minerals and these served as control group. The bucks were now ...

  3. Clinical study on the changes of perioperative serum thyroid hormone during heart surgery

    International Nuclear Information System (INIS)

    Xu Zhonghua; Qian Yongyue; Liu Zengli; Wu Jinchang; Yang Chen

    2002-01-01

    To observe the changes of perioperative serum thyroid hormone and their clinical significance, blood samples were obtained from 20 patients before, during and after heart operations. Thyroid hormones were measured by radioimmunoassay. The results showed that serum T 3 , T 4 and FT 3 levels significantly declined during cardiopulmonary bypass (CPB) and thereafter. Serum T 3 and T 4 concentrations reached their nadir at the lowest hypothermia of CPB. TSH and FT 4 levels remained normal ranges at postoperative sampling times. Conclusions: CPB would severely affect patients' thyroid function, thus simulated a 'low T 3 syndrome', and low T 3 syndrome would produce side effects on postoperative heart function

  4. Reproducibility of biomarkers in induced sputum and in serum from chronic smokers.

    Science.gov (United States)

    Zuiker, Rob G J A; Kamerling, Ingrid M C; Morelli, Nicoletta; Calderon, Cesar; Boot, J Diderik; de Kam, Marieke; Diamant, Zuzana; Burggraaf, Jacobus; Cohen, Adam F

    2015-08-01

    Soluble inflammatory markers obtained from non-invasive airway sampling such as induced sputum may be useful biomarkers for targeted pharmaceutical interventions. However, before these soluble markers can be used as potential targets, their variability and reproducibility need to be established in distinct study populations. This study aimed to assess the reproducibility of biomarkers obtained from induced sputum and serum in chronic smokers and non-smokers. Sputum and serum samples were obtained from 16 healthy non-smokers and 16 asymptomatic chronic smokers (for both groups: 8M/8F, 30-52 years, FEV1 ≥80% pred.; ≥10 pack years for the smokers) on 2 separate visits 4-10 days apart. Soluble markers in serum and sputum were analysed by ELISA. The differences between smokers vs non-smokers were analysed with a t-test and variability was assessed on log-transformed data by a mixed model ANOVA. Analysable sputum samples could be obtained from all 32 subjects. In both study populations neutrophils and macrophages were the predominant cell types. Serum Pulmonary Surfactant Associated Protein D had favourable reproducibility criteria for reliability ratio (0.99), intra-subject coefficient of variation (11.2%) and the Bland Altman limits of agreement. Furthermore, chronic smokers, compared to non-smokers, had significantly higher sputum concentrations of IL-8 (1094.6 pg/mL vs 460.8 pg/mL, p = 0.006)), and higher serum concentrations of Pulmonary Surfactant Associated Protein D (110.9 pg/mL vs 64.7 pg/mL, p = 0.019), and lower concentrations of Serum Amyloid A (1352.4 pg/mL vs 2297.5 pg/mL, p = 0.022). Serum Pulmonary Surfactant Associated Protein D proved to be a biomarker that fulfilled the criteria for reproducibility in both study groups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Relationship between RBC Mercury Levels and Serum n3 Polyunsaturated Fatty Acid Concentrations among Japanese Men and Women

    International Nuclear Information System (INIS)

    Tsuji, M.; Ando, T.; Wakamiya, J.; Koriyama, Ch.; Akiba, S.; Kitano, T.

    2012-01-01

    Aims. To evaluate potential health risk and benefits of fish consumption, the association of fish consumption with total mercury levels in red blood cells (RBCs) and serum eicosapentaenoic acid (EPA) concentrations was examined. Subjects and Methods. Study subjects were 269 Japanese (98 men and 171 women) living in a remote island of Kagoshima, and their blood was drawn in 1994. Results. Total mercury levels were related to weekly fish consumption among women (P=0.035) but not among men (P=0.643). However, serum EPA levels were not related to fish consumption in both women and men. In contrast, EPA levels in the high-density lipoprotein (HDL) fraction of the sera were significantly related to fish consumption (P values for men and women were 0.014 and 0.073, resp.). Interestingly, mercury levels were related to serum EPA levels and EPA in the HDL fraction of the sera (P=0.001) among women (P=0.005) but not among men. Sex differences in fish species consumed may be an explanation for the observed sex difference. Conclusion. Those findings suggest that the health benefit of fish consumption can be maximized by the careful selection of fish species consumed

  6. Iterative importance sampling algorithms for parameter estimation

    OpenAIRE

    Morzfeld, Matthias; Day, Marcus S.; Grout, Ray W.; Pau, George Shu Heng; Finsterle, Stefan A.; Bell, John B.

    2016-01-01

    In parameter estimation problems one computes a posterior distribution over uncertain parameters defined jointly by a prior distribution, a model, and noisy data. Markov Chain Monte Carlo (MCMC) is often used for the numerical solution of such problems. An alternative to MCMC is importance sampling, which can exhibit near perfect scaling with the number of cores on high performance computing systems because samples are drawn independently. However, finding a suitable proposal distribution is ...

  7. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  8. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  9. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  10. Potential of cancer screening with serum surface-enhanced Raman spectroscopy and a support vector machine

    International Nuclear Information System (INIS)

    Li, S X; Zhang, Y J; Zeng, Q Y; Li, L F; Guo, Z Y; Liu, Z M; Xiong, H L; Liu, S H

    2014-01-01

    Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA–SVM methods. The results prove that a RBF kernel PCA–SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample. (letters)

  11. Comparison of Serum Protein Electrophoresis Values in Wild and Captive Whooping Cranes ( Grus americana ).

    Science.gov (United States)

    Hausmann, Jennifer C; Cray, Carolyn; Hartup, Barry K

    2015-09-01

    Protein electrophoresis of serum samples from endangered, wild whooping cranes ( Grus americana ) was performed to help assess the health of the only self-sustaining, migratory population in North America. Serum samples from wild adult cranes (n = 22) were taken at Aransas National Wildlife Refuge, Texas, USA during winter. Wild juvenile cranes (n = 26) were sampled at Wood Buffalo National Park, Northwest Territories, Canada, in midsummer. All captive crane samples were acquired from the International Crane Foundation, Baraboo, WI, USA. Captive adult cranes (n = 30) were sampled during annual examinations, and archived serum samples from captive juvenile cranes (n = 19) were selected to match the estimated age of wild juveniles. Wild juveniles had significantly lower concentrations of all protein fractions than wild adults, except for prealbumin and γ globulins. All protein fraction concentrations for wild juveniles were significantly lower compared with captive juveniles, except for prealbumin and γ globulins, which were higher. Wild adults had significantly greater γ globulin concentrations than captive adults. Captive juveniles had significantly lower prealbumin and albumin concentrations and albumin : globulin ratios than captive adults. The higher γ globulin concentrations in wild versus captive cranes are likely because of increased antigenic exposure and immune stimulation. Protein fraction concentrations vary significantly with age and natural history in this species. Reference intervals for serum protein electrophoresis results from captive adult whooping cranes are provided in this study.

  12. Serum total and free carnitine levels in children with asthma.

    Science.gov (United States)

    Asilsoy, Suna; Bekem, Ozlem; Karaman, Ozkan; Uzuner, Nevin; Kavukçu, Salih

    2009-02-01

    Serum carnitine is decreased in recurrent pulmonary infections. We aimed to evaluate serum carnitine levels in asthmatic children. Study group consisted of children with stable asthma and those with acute asthma attacks, while control group included healthy children. Attack severity was determined by the pulmonary score system. Total and free carnitine levels were studied in one blood sample from the control group and stable asthmatics and in two samples from children with acute asthma exacerbation during and after the attack. All the 40 patients in the study group had moderate asthma including 30 with acute attack (13 mild and 17 moderate) and 10 with stable asthma. Carnitine levels were significantly lower in acute attack asthmatics than in the stable asthmatics and controls, while there was no significant difference between the latter two groups. Carnitine levels were not different between asthmatics with mild and moderate attack, and were similar during and after an acute attack. Serum carnitine levels decrease in children with moderate asthma during exacerbation of asthma and shortly thereafter. Further studies are needed to evaluate the effect of carnitine treatment on serum carnitine level.

  13. Studies of serial serum electrophoretic pattern for prognosis in various cancer patients during irradiation

    International Nuclear Information System (INIS)

    Ra, Woo Youn; Woo, Won Hyung

    1971-01-01

    During the period from June. 1969 to Dec. 1970, the serum protein electrophoretic patterns of 44 cases of various cancer patients have been studied to determine the alterations in serum protein fractions in patients who were responding to irradiation or those failing. The serum electrophoretic pattern could be observed as an indicator of prognosis or radiosensitivity. A blood sample was obtained prior to any treatment and the follow up sampling was performed 2 times during radiation therapy. Serum total protein was determined by the method of Wolfson and serum electrophoresis was carried out by using Spinoco Model R B electrophoresis system. The results were following: Seven cases out of cases of cervical cancer responding favorably to radiotherapy showed decreased in Alpha-2 globulin fraction were increased. A case whose third time serum electrophoretic pattern showed multiple myeloma type died 5 months after radiotherapy with bone metastasis. Four cases out of 9 cases of favorably responded breast cancer patients showed decreased in Alpha-2 globulin foraction compared with 2 cases of unfavorable response showed increased in Alpha-2 globulin fraction

  14. Studies of serial serum electrophoretic pattern for prognosis in various cancer patients during irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ra, Woo Youn; Woo, Won Hyung [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    1971-10-15

    During the period from June. 1969 to Dec. 1970, the serum protein electrophoretic patterns of 44 cases of various cancer patients have been studied to determine the alterations in serum protein fractions in patients who were responding to irradiation or those failing. The serum electrophoretic pattern could be observed as an indicator of prognosis or radiosensitivity. A blood sample was obtained prior to any treatment and the follow up sampling was performed 2 times during radiation therapy. Serum total protein was determined by the method of Wolfson and serum electrophoresis was carried out by using Spinoco Model R B electrophoresis system. The results were following: Seven cases out of cases of cervical cancer responding favorably to radiotherapy showed decreased in Alpha-2 globulin fraction were increased. A case whose third time serum electrophoretic pattern showed multiple myeloma type died 5 months after radiotherapy with bone metastasis. Four cases out of 9 cases of favorably responded breast cancer patients showed decreased in Alpha-2 globulin foraction compared with 2 cases of unfavorable response showed increased in Alpha-2 globulin fraction.

  15. Variation in risk indicators of cardiovascular disease during the menstrual cycle: an investigation of within-subject variations in glutathione peroxidase, haemostatic variables, lipids and lipoproteins in healthy young women

    DEFF Research Database (Denmark)

    Larsen, L F; Andersen, H R; Hansen, A B

    1996-01-01

    Variations in erythrocyte glutathione peroxidase activity, serum concentrations of lipids and lipoproteins and in blood coagulation and fibrinolysis during the menstrual cycle were studied in healthy young women. Blood samples were drawn twice a week for 9 weeks. A group of males was used...

  16. The impact of FCN2 polymorphisms and haplotypes on the Ficolin-2 serum levels

    DEFF Research Database (Denmark)

    Munthe-Fog, L; Hummelshøj, T; Hansen, B E

    2007-01-01

    Ficolin-2 in serum samples and identified FCN2 genotypes with a Taq Man-based minor groove binder assay and by sequencing. Serum samples were applied to gel-permeation chromatography and fractions were analysed by an ELISA, SDS-PAGE and subsequently Western blotting. In 214 Danish blood donors, the median...... Ficolin-2 serum concentration was determined to 5.4 microg/ml (range: 1.0-12.2 microg/ml). An ELISA, SDS-PAGE and Western blot analysis of gel-permeation chromatography fractions showed that Ficolin-2 comprises a mixture of covalently and non-covalently linked Ficolin-2 oligomers independent...

  17. Biochemical Changes in the Serum and Liver of albino rats exposed ...

    African Journals Online (AJOL)

    Biochemical changes in the serum and liver of albino rats chronically exposed to rats administered 5gk-1 , 7.5gk-1 and 15gk-1 of gasoline , kerosine and crude petroleum(bonny light) respectively were studied. The petroleum samples were administered intraperitoneally and the biochemical changes in the rat serum and the ...

  18. Elevated serum leptin levels in patients with acute myocardial infarction; correlation with coronary angiographic and echocardiographic findings

    Directory of Open Access Journals (Sweden)

    Khafaji Hadi AR

    2012-05-01

    Full Text Available Abstract Background To assess the relationship between serial serum leptin levels in patients with acute myocardial infarction (AMI who received thrombolysis and the degree of coronary atherosclerosis, coronary reperfusion, echocardiographic findings, and clinical outcome. 51 consecutive patients presenting with AMI were studied. Clinical characteristics including age, sex, body mass index (BMI and cardiovascular risk factors were recorded. Serial serum leptin levels at the time of admission and subsequently at 0, 6, 12, 24, 36, 60 hours afterwards were obtained. Coronary angiography was performed in 34 patients; the relation between serum leptin levels and evidence of coronary reperfusion as well as the extent of coronary atherosclerosis according to the coronary artery surgery study classification (CASS were evaluated. Echocardiographic evaluation was performed in all patients. 36 matched patients were enrolled as control group who had serum leptin level 9.4 ± 6.5 ng/ml. Results The patients mean age was 50.5 ± 10.6 years. There were 47 males and 3 females. 37.1% were diabetics, 23.5% were hypertensive, 21.6% were dyslipidemic and 22.7% were obese (BMI ≥ 30. Leptin concentrations (ng/ml increased and peaked at the 4th sample (36 hrs after admission (mean ± SD sample (1 =9.55 ± 7.4, sample (2 =12.9 ± 8.4, sample (3 =13.8 ± 10.4, sample (4 =18.9 ± 18.1, sample (5 =11.4 ± 6.5, sample (6 =10.8 ± 8.9 ng/ml. There was a significant correlation between serum leptin and BMI (r = 0.342; p = 0.03. Leptin levels correlated significantly to creatine kinase level on the second day (r = 0.43, p ≤ 0.01. Significant correlation of mean serum leptin with the ejection fraction (P p = 0.8. There was a trend for an increase in the mean serum leptin levels with increasing number of diseased vessels. There was no correlation between serum leptin levels and outcome neither during the

  19. Serum metabonomics of rats irradiated by low-dose γ-rays

    Directory of Open Access Journals (Sweden)

    Ying HE

    2014-08-01

    Full Text Available Objective To explore the effect of low-dose γ-rays on the metabolites in rat serum. Methods Sixteen healthy male SD rats were randomly divided into control group and irradiated group (n=8. The rats in irradiated group were irradiated by 60Co γ-rays with a dose rate of 72mGy/h for 7 days (1 hour per day. At the 7th day after irradiation, blood samples were taken from abdominal aorta to obtain the serum. The metabolic fingerprints of serum were obtained from the two groups of rats, and 1H nuclear magnetic resonance (NMR spectroscopy, principal component analysis (PCA and orthogonal signal correction-partial least squares (OSC-PLS method were used for pattern recognition, and the difference in metabolite profile between two groups was identified by SIMCA-P software. Results The rat serum 1H NMR spectra revealed a significant difference between control group and irradiated group, the OSC-PLS plots of the serum samples presented marked clustering between two groups. Compared with the control group, the content of lipid, glucose, creatine, glycine/glucose, high density lipoprotein, low density lipoprotein, very low density lipoprotein/low density lipoprotein and unsaturated fatty acid increased, while the content of lactic acid, threonine/lipid, alanine, N-acetyl glycoprotein 1, N-acetyl glycoprotein 2, saturated fatty acid and phosphatidyl choline decreased in irradiated group. Conclusion Irradiation with low-dose γ-ray could induce changes in metabolites in rat serum, concerning mainly immune function, energy metabolism, carbohydrate metabolism and lipid metabolism. DOI: 10.11855/j.issn.0577-7402.2014.07.02

  20. Serum protein profile at remission can accurately assess therapeutic outcomes and survival for serous ovarian cancer.

    Directory of Open Access Journals (Sweden)

    Jinhua Wang

    Full Text Available BACKGROUND: Biomarkers play critical roles in early detection, diagnosis and monitoring of therapeutic outcome and recurrence of cancer. Previous biomarker research on ovarian cancer (OC has mostly focused on the discovery and validation of diagnostic biomarkers. The primary purpose of this study is to identify serum biomarkers for prognosis and therapeutic outcomes of ovarian cancer. EXPERIMENTAL DESIGN: Forty serum proteins were analyzed in 70 serum samples from healthy controls (HC and 101 serum samples from serous OC patients at three different disease phases: post diagnosis (PD, remission (RM and recurrence (RC. The utility of serum proteins as OC biomarkers was evaluated using a variety of statistical methods including survival analysis. RESULTS: Ten serum proteins (PDGF-AB/BB, PDGF-AA, CRP, sFas, CA125, SAA, sTNFRII, sIL-6R, IGFBP6 and MDC have individually good area-under-the-curve (AUC values (AUC = 0.69-0.86 and more than 10 three-marker combinations have excellent AUC values (0.91-0.93 in distinguishing active cancer samples (PD & RC from HC. The mean serum protein levels for RM samples are usually intermediate between HC and OC patients with active cancer (PD & RC. Most importantly, five proteins (sICAM1, RANTES, sgp130, sTNFR-II and sVCAM1 measured at remission can classify, individually and in combination, serous OC patients into two subsets with significantly different overall survival (best HR = 17, p<10(-3. CONCLUSION: We identified five serum proteins which, when measured at remission, can accurately predict the overall survival of serous OC patients, suggesting that they may be useful for monitoring the therapeutic outcomes for ovarian cancer.

  1. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  2. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  3. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

  4. Analysis of trace elements in serum from human eating irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi; Chen Shijie; Gao Sumei

    1987-01-01

    A method of trace element analysis by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AEC) in serum from human eating food preserved by irradiation is described. Trace element analysis in human serum is one of the research projects concerning the wholesomeness. 78 serum samples of the human eating food preserved by irradiation were collected. After ashing and solving ICP-AES analysis of serum is performed for detecting 12 trace elements in specimen solution. The detection limitations are in the range of 10 -2 - 10 -3 ppm for differemt elements. The recoveries of elements are over 73%. Concentrations of 12 trace elements in 78 human serum has been calculated with F and t tests at PDP 11/70 computer and it was concluded that there is no significant difference between testing group and control group

  5. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  6. Low temperature annealing of cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Bech, Jakob Ilsted; Hansen, Niels

    2015-01-01

    Cold-drawn pearlitic steel wires are nanostructured and the flow stress at room temperature can reach values above 6 GPa. A typical characteristic of the nanostructured metals, is the low ductility and thermal stability. In order to optimize both the processing and application of the wires......, the thermal behaviour is of interest. This has been studied by annealing the wires for 1h at temperatures from ambient temperature to 300 ℃ (573 K). It is expected that a raising temperature may lead to structural changes and a reduction in strength. The change in strength is however not expected to be large....... For this reason we have applied a very precise technique to measure the tensile properties of the wires from a strain of 10-4 to the maximum strain of about 1-2%. The structural changes have also been followed to estimate and relate strength changes to changes in structural parameters and morphology....

  7. Serum progranulin as an indicator of neutrophilic airway inflammation and asthma severity.

    Science.gov (United States)

    Park, So Young; Hong, Gyong Hwa; Park, Sunjoo; Shin, Bomi; Yoon, Sun-Young; Kwon, Hyouk-Soo; Kim, Tae-Bum; Moon, Hee-Bom; Cho, You Sook

    2016-12-01

    Progranulin, a protein secreted from the airway epithelium, is known to attenuate the downstream cascade of neutrophilic inflammation in particular. We hypothesized that progranulin may have a role in inflammatory regulation in asthma. To investigate the association between serum progranulin levels and various clinical features in patients with asthma. Serum samples and clinical data of 475 patients with asthma and 35 healthy controls at a tertiary referral hospital and its affiliated health promotion center were collected. Serum progranulin levels were compared between patients with asthma and healthy controls and then were compared within the patients with asthma in terms of pulmonary function and measures of inflammatory status. Univariate and multivariate analyses were performed to identify factors associated with severity of asthma. Serum progranulin levels were significantly lower in the asthma group than in healthy group and were positively correlated with prebronchodilator forced expiratory volume in 1 second predicted within patients with asthma. We found a negative correlation between serum progranulin levels and blood neutrophil counts. Multivariate analysis revealed that higher serum progranulin levels were associated with a lower risk of severe asthma (odds ratio, 0.888; 95% confidence interval, 0.846-0.932; P progranulin remains unknown, we suggest that serum progranulin may be an indicator of severe asthma with airflow limitation. Future studies with comprehensive airway sampling strategies are warranted to clarify its role, particularly in neutrophilic asthma. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  8. Organochlorine pesticide residue levels in blood serum of inhabitants from Veracruz, Mexico.

    Science.gov (United States)

    Waliszewski, Stefan M; Caba, M; Herrero-Mercado, M; Saldariaga-Noreña, H; Meza, E; Zepeda, R; Martínez-Valenzuela, C; Gómez Arroyo, S; Villalobos Pietrini, R

    2012-09-01

    The objective of the present study was to monitor the levels of organochlorine pesticides HCB; α-, β-, γ-HCH; pp'DDE; op'DDT; and pp'DDT in blood serum of Veracruz, Mexico inhabitants. Organochlorine pesticides were analyzed in 150 blood serum samples that constituted that which remained after clinical analyses, using gas chromatography-electron-capture detection (GC-ECD). The results were expressed as milligrams per kilogram on fat basis and micrograms per liter on wet weight. Only the following pesticides were detected: p,p'-DDE was the major organochlorine component, detected in 100% of samples at mean 15.8 mg/kg and 8.4 μg/L; p,p'-DDT was presented in 41.3.% of monitored samples at mean 3.1 mg/kg and 1.4 μg/L; β-HCH was found in 48.6% of the samples at mean 4.9 mg/kg and 2.7 μg/L; op'DDT was determined to be in only 3.3% of monitored samples at mean 2.7 mg/kg and 1.4 μg/L. The pooled samples divided according to sex showed significant differences of β-HCH and pp'DDE concentrations in females. The samples grouped according to age presented the third tertile as more contaminated in both sexes, indicating age as a positively associated factor with serum organochlorine pesticide levels in Veracruz inhabitants.

  9. Quantitative Assessment of Serum Nickel and Chromium Levels in Orthodontic Patients: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Rohan Rai

    2011-01-01

    Results : Results obtained indicated that although nickel level in the serum was significant initially in the samples when compared to the controls, there was a gradual decrease of serum nickel level when the appliance was present for a longer duration. However, serum chromium levels showed no significant changes with time.

  10. Serum levo-carnitine levels and skeletal muscle functions in type 2 diabetes mellitus in rodents

    International Nuclear Information System (INIS)

    Aleem, S.B.; Hussain, M.M.; Farooq, Y.

    2013-01-01

    Objective: To study serum levo-carnitine (l-carnitine) levels and isometric contraction, force frequency relationship and fatigue of rodent skeletal muscles in type 2 diabetes mellitus. Study Design: Randomized controlled trial. Place and Duration of Study: Physiology Department, Army Medical College, Rawalpindi, from January 2009 to January 2010. Methodology: Sixty Sprague-Dawley rats were randomly divided into two groups; group I (control), fed on normal diet ad libitum and Group II (diabetic), fed on high fat diet and administered streptozocin to induce type 2 diabetes mellitus (T2DM). At 21st day, plasma glucose and TG/HDL ratio were measured to confirm the development of T2DM in group II. At 28th day, blood was drawn by intracardiac puncture to estimate serum levo-carnitine levels. Contractile functions of skeletal muscles were assessed by using iWorx AHK/214 physiological data acquisition unit. Simple muscle twitches, maximum isometric twitch tension (MITT), time-to-peak twitch tension (TPTT) and time-to-relax to 50% of the peak twitch tension (1/2RT) of extensor digitorum muscles were recorded. Muscles were stimulated at higher frequencies to determine maximum fused tetanic tension (MFTT), maximum fused tetanic tension after fatigue protocol (TTFP) and recovery from fatigue (RF). Results: Serum levo-carnitine level decreased significantly in the diabetic group. Both groups had similar MITT, TPTT and 1/2RT but decline in MFTT, TTFP and RF was significant in the diabetic rats. Conclusion: T2DM adversely affected serum levo-carnitine levels and the contractile functions of rodent skeletal muscle at high frequency stimulation. (author)

  11. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  12. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    Science.gov (United States)

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  13. Measurement of hydroxylated PCB metabolites for Slovakia maternal blood serums

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S.; Athanasiadou, M; Bergman, A. [Stockholm Univ., Stockholm (Sweden); Charles, J.; Zhao, G.; Hertz-Picciotto, I. [California Univ., Sacramento, CA (United States); Petrik, J.; Kocan, A; Trnovec, T. [Bratislava Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    2005-07-01

    Although it is known that polychlorinated biphenyls (PCBs) have adverse impacts on human health, it is not clear if human health impacts are caused by the PCBs or their related hydroxylated (OH) PCB metabolite compounds. This study measured OH-PCB metabolites in the maternal blood serum specimens from the Svidnik and Michalovce areas in eastern Slovakia where PCBs were intensively produced and inadequately disposed. The aim of the study was to characterize and quantify levels of specific OH-PCB metabolites in Slovakian maternal serums exposed to high environmental PCB levels. All specimens were analyzed for PCBs, and a subset of the samples was analyzed for OH-PCB metabolites. The Wallenburg blood extraction method was adopted to separate the OH-PCBs from the blood serums. Final eluates and calibration standards were spiked with PCB209 as an injection standard before gas chromatography (GC) analysis. OH-PCBs in the samples range from 75{+-}9 per cent to 101{+-}11 per cent. Median concentrations of OH-PCB metabolites of Michalovce samples were approximately twice as high as for the Svidnik samples. Concentrations of OH-PCBs of Michalovce blood samples were comparable to samples obtained from northern Canadian female Inuit and Faroe Island females, and were considered to be among the highest OH-PCB concentrations obtained in human blood. It was concluded that further research is needed to understand the placental transfer of OH-PCBs to the fetus, as well as epidemiological approaches to determine the relationship between the exposure of OH-PCB metabolites and child development. 12 refs., 2 figs.

  14. Inositol and hepatic lipidosis. II. Effect of inositol supplementation and time from parturition on serum insulin, thyroxine and triiodothyronine and their relationship to serum and liver lipids in dairy cows.

    Science.gov (United States)

    Gerloff, B J; Herdt, T H; Wells, W W; Nachreiner, R F; Emery, R S

    1986-06-01

    Percutaneous liver biopsies and blood samples were obtained from 80 dairy cows in nine Michigan herds over the peripartum period. Thirty-nine cows were fed 17 g of supplemental inositol and 41 were fed a placebo. Liver biopsies were assayed for total myoinositol and triglyceride (TG) concentrations. Blood samples were assayed for serum dextran precipitable cholesterol, nonesterified fatty acids (NEFA), insulin, thyroxine (T4), free (FT4), triiodothyronine (T3) and free T3 (FT3) concentrations. Serum concentrations of insulin and the thyroid hormones decreased near parturition, with lowest concentrations occurring in the immediate postpartum period. Concentrations of T3 correlated well with T4, and the concentrations of free thyroid hormones reflected concentrations of total thyroid hormones. The percentage of hormone in the free fraction remained constant over time. Serum insulin, T3 and T4 were negatively correlated with serum NEFA and liver TG concentrations. Thyroid hormone concentrations were positively correlated with serum dextran precipitable cholesterol concentrations. Inositol supplementation was associated with reduced circulating T3 and FT3 concentrations, but not T4 and FT4 concentrations. Changes in hormone concentrations at parturition and their relationship to liver TG and serum NEFA concentrations were consistent with a metabolic adaptation by the dairy cow to the negative energy balance of early lactation.

  15. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Organohalogenated contaminants (OHCs) in the serum and hair of pet cats and dogs: Biosentinels of indoor pollution

    International Nuclear Information System (INIS)

    Ali, Nadeem; Malik, Riffat Naseem; Mehdi, Toufeer; Eqani, Syed Ali Musstjab Akber Shah; Javeed, Aqeel; Neels, Hugo; Covaci, Adrian

    2013-01-01

    Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p′-DDE, was the major OHC in cat serum (N = 20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p′-DDE was not detected in dog serum (N = 16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median = 6.0 ng/g lw) than cat serum (median = 2.2 ng/g lw). Levels of most OHCs were significantly higher (p ∑NBFRs > ∑PBDEs > ∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N = 12), ∑DDTs (r = 0.65, p = 0.001) were significantly correlated, while for all other OHCs no significant correlations (p < 0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to document the presence of OHCs in pets from Pakistan and provides baseline information for future monitoring of OHCs in pets. - Highlights: ► Different classes of OHCs were analyzed in pet serum and hair from Pakistan. ► p,p′-DDE was the major pollutant in cat serum, but was < LOQ in dog serum. ► Except HO-PCBs all other classes of OHCs were higher in cat than in dog serum. ► Three of the novel BFRs were detected in pet hair samples. ► Most of OHCs were present at higher levels in cats than humans from the same region

  17. Photographic but not line-drawn faces show early perceptual neural sensitivity to eye gaze direction

    Directory of Open Access Journals (Sweden)

    Alejandra eRossi

    2015-04-01

    Full Text Available Our brains readily decode facial movements and changes in social attention, reflected in earlier and larger N170 event-related potentials (ERPs to viewing gaze aversions vs. direct gaze in real faces (Puce et al. 2000. In contrast, gaze aversions in line-drawn faces do not produce these N170 differences (Rossi et al., 2014, suggesting that physical stimulus properties or experimental context may drive these effects. Here we investigated the role of stimulus-induced context on neurophysiological responses to dynamic gaze. Sixteen healthy adults viewed line-drawn and real faces, with dynamic eye aversion and direct gaze transitions, and control stimuli (scrambled arrays and checkerboards while continuous electroencephalographic (EEG activity was recorded. EEG data from 2 temporo-occipital clusters of 9 electrodes in each hemisphere where N170 activity is known to be maximal were selected for analysis. N170 peak amplitude and latency, and temporal dynamics from event-related spectral perturbations (ERSPs were measured in 16 healthy subjects. Real faces generated larger N170s for averted vs. direct gaze motion, however, N170s to real and direct gaze were as large as those to respective controls. N170 amplitude did not differ across line-drawn gaze changes. Overall, bilateral mean gamma power changes for faces relative to control stimuli occurred between 150-350 ms, potentially reflecting signal detection of facial motion.Our data indicate that experimental context does not drive N170 differences to viewed gaze changes. Low-level stimulus properties, such as the high sclera/iris contrast change in real eyes likely drive the N170 changes to viewed aversive movements.

  18. Determination of human albumin in serum and urine samples by constant-energy synchronous fluorescence method.

    Science.gov (United States)

    Madrakian, Tayyebeh; Bagheri, Habibollah; Afkhami, Abbas

    2015-08-01

    A sensitive spectrofluorimetric method using constant-energy synchronous fluorescence technique is proposed for the determination of human albumin without separation. In this method, no reagent was used for enhancement of the fluorescence signal of albumin in the solution. Effects of some parameters, such as energy difference between excitation and emission monochromators (ΔE), emission and excitation slit widths and scan rate of wavelength were studied and the optimum conditions were established. For this purpose factorial design and response surface method were employed for optimization of the effective parameters on the fluorescence signal. The results showed that the scan rate of the wavelength has no significant effect on the analytical signal. The calibration curve was linear in the range 0.1-220.0 µg mL(-1) of albumin with a detection limit of 7.0 × 10(-3)  µg mL(-1). The relative standard deviations (RSD) for six replicate measurements of albumin were calculated as 2.2%, 1.7% and 1.3% for 0.5, 10.0 and 100.0 µg mL(-1) albumin, respectively. Furthermore the proposed method has been employed for the determination of albumin in human serum and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Serum proteomics reveals systemic dysregulation of innate immunity in type 1 diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qibin; Fillmore, Thomas L.; Schepmoes, Athena A.; Clauss, Therese RW; Gritsenko, Marina A.; Mueller, Patricia W.; Rewers, Marian; Atkinson, Mark A.; Smith, Richard D.; Metz, Thomas O.

    2013-01-14

    Using global liquid chromatography-mass spectrometry (LC-MS)-based proteomics analyses, we identified 24 serum proteins significantly variant between those with type 1 diabetes and healthy controls. Functionally, these proteins represent innate immune responses, the activation cascade of complement, inflammatory responses and blood coagulation. Targeted verification analyses were performed on 52 surrogate peptides representing these proteins with serum samples from an antibody standardization program cohort of 100 healthy control and 50 type 1 diabetic subjects, and 16 peptides were verified having very good discriminating power, with areas under the receiver operator characteristic curve ≥ 0.8. Further validation with blinded serum samples from an independent cohort (10 healthy control and 10 type 1 diabetic) demonstrated that peptides from platelet basic protein and C1 inhibitor achieved both 100% sensitivity and 100% specificity for classification of samples. The disease specificity of these proteins was assessed using serum from 50 age matched type 2 diabetic individuals, and a subset of proteins, particularly C1 inhibitor were exceptionally good discriminators between these two forms of diabetes. The panel of biomarkers distinguishing those with type 1 diabetes from healthy control and type 2 diabetes suggests dysregulated innate immune responses may be associated with the development of this disorder.

  20. Serum and Plasma Metabolomic Biomarkers for Lung Cancer.

    Science.gov (United States)

    Kumar, Nishith; Shahjaman, Md; Mollah, Md Nurul Haque; Islam, S M Shahinul; Hoque, Md Aminul

    2017-01-01

    In drug invention and early disease prediction of lung cancer, metabolomic biomarker detection is very important. Mortality rate can be decreased, if cancer is predicted at the earlier stage. Recent diagnostic techniques for lung cancer are not prognosis diagnostic techniques. However, if we know the name of the metabolites, whose intensity levels are considerably changing between cancer subject and control subject, then it will be easy to early diagnosis the disease as well as to discover the drug. Therefore, in this paper we have identified the influential plasma and serum blood sample metabolites for lung cancer and also identified the biomarkers that will be helpful for early disease prediction as well as for drug invention. To identify the influential metabolites, we considered a parametric and a nonparametric test namely student׳s t-test as parametric and Kruskal-Wallis test as non-parametric test. We also categorized the up-regulated and down-regulated metabolites by the heatmap plot and identified the biomarkers by support vector machine (SVM) classifier and pathway analysis. From our analysis, we got 27 influential (p-value<0.05) metabolites from plasma sample and 13 influential (p-value<0.05) metabolites from serum sample. According to the importance plot through SVM classifier, pathway analysis and correlation network analysis, we declared 4 metabolites (taurine, aspertic acid, glutamine and pyruvic acid) as plasma biomarker and 3 metabolites (aspartic acid, taurine and inosine) as serum biomarker.

  1. Effects of blood collection conditions on ovarian cancer serum markers.

    Directory of Open Access Journals (Sweden)

    Jason D Thorpe

    2007-12-01

    Full Text Available Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies.We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer.Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.

  2. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  3. Clinical Usefulness of Serum Cystatin C as a Marker of Renal Function

    Directory of Open Access Journals (Sweden)

    Kwang-Sook Woo

    2014-08-01

    Full Text Available BackgroundAccurate renal function measurements are important in the diagnosis and treatment of kidney diseases. In contrast to creatinine, the production of serum cystatin C has been extensively reported to be unaffected by body muscle mass, age, gender, and nutritional status.MethodsOur study included 37 samples from diabetic chronic kidney disease (CKD patients for whom serum creatinine tests had been requested and 40 samples from a healthy populations in Dong-A University Hospital between May 2010 and June 2010. The assay precision (i.e., the coefficient of variation and the reference range of the serum cystatin C test were evaluated. We compared the estimated glomerular filtration rates (GFRs based on cystatin C with those based on creatinine. Moreover, we investigated the influences of age, gender, weight, and muscle mass on serum creatinine and serum cystatin C.ResultsThere was a positive correlation between GFR based on creatinine and that based on cystatin C (r=0.79, P<0.0001 among the diabetic CKD patients. Serum creatinine and cystatin C were significantly correlated with body weight and muscle mass, but the strengths of these correlations were greater for serum creatinine. The precision study revealed excellent results for both the high and low controls. The 95% reference interval of cystatin C in the healthy population was 0.371 to 1.236 mg/L.ConclusionBased on these results, we conclude that, despite the strong correlation between serum creatinine and cystatin C, cystatin C is less affected by weight and muscle mass and might represent a better alternative for the assessment of renal function.

  4. Can serums be replaced by Mueller‑Hinton agar in germ tube test?

    African Journals Online (AJOL)

    2016-03-03

    Mar 3, 2016 ... various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and Mueller‑Hinton agar (MHA). Materials and Methods: Fifty species isolated from various clinical samples that were defined as C. albicans by both conventional and DNA sequence analysis methods were included in the ...

  5. 7 CFR 27.20 - Drawing and handling of samples of cotton; inspection of bales.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Drawing and handling of samples of cotton; inspection... Regulations Inspection and Samples § 27.20 Drawing and handling of samples of cotton; inspection of bales. One sample shall be drawn from the top side of each bale and one from the bottom side. Each such sample shall...

  6. Plasma and serum lipidomics of healthy white adults shows characteristic profiles by subjects' gender and age.

    Directory of Open Access Journals (Sweden)

    Masaki Ishikawa

    Full Text Available Blood is a commonly used biofluid for biomarker discovery. Although blood lipid metabolites are considered to be potential biomarker candidates, their fundamental properties are not well characterized. We aimed to (1 investigate the matrix type (serum vs. plasma that may be preferable for lipid biomarker exploration, (2 elucidate age- and gender-associated differences in lipid metabolite levels, and (3 examine the stability of lipid metabolites in matrix samples subjected to repeated freeze-thaw cycles. Using liquid chromatography-mass spectrometry, we performed lipidomic analyses for fasting plasma and serum samples for four groups (15 subjects/group of young and elderly (25-34 and 55-64 years old, respectively males and females and for an additional aliquot of samples from young males, which were subjected to repeated freeze-thaw cycles. Lysophosphatidylcholine and diacylglycerol levels were higher in serum than in plasma samples, suggesting that the clotting process influences serum lipid metabolite levels. Gender-associated differences highlighted that the levels of many sphingomyelin species were significantly higher in females than in males, irrespective of age and matrix (plasma and serum. Age-associated differences were more prominent in females than in males, and in both matrices, levels of many triacylglycerols were significantly higher in elderly females than in young females. Plasma and serum levels of most lipid metabolites were reduced by freeze-thawing. Our results indicate that plasma is an optimal matrix for exploring lipid biomarkers because it represents the original properties of an individual's blood sample. In addition, the levels of some blood lipid species of healthy adults showed gender- and age-associated differences; thus, this should be considered during biomarker exploration and its application in diagnostics. Our fundamental findings on sample selection and handling procedures for measuring blood lipid metabolites

  7. Comparison of the extraction and determination of serum exosome and miRNA in serum and the detection of miR-27a-3p in serum exosome of ALS patients.

    Science.gov (United States)

    Xu, Qian; Zhao, Yuying; Zhou, Xiaoyan; Luan, Jing; Cui, Yazhou; Han, Jinxiang

    2018-02-01

    Amyotrophic Lateral Sclerosis (ALS) is a muscle-bone degenerative disease, which lacks a specific index for diagnosis. In our previous studies, we found that exosomes mediated the interaction mechanism between muscle and bone at the cellular level, and myoblast exosomes can transfer miR-27a-3p to promote osteoblast mineralization. Therefore, we suppose that the expression of miR-27a-3p in the serum exosomes of ALS patients also changes. In this study, we used healthy human serum as a sample to find out the conditions and methods for extraction and detection. Then through comparison of the expression of miR-27a-3p in the serum exosomes of 10 ALS patients and healthy subjects, we found that in the ALS patients miR-27a-3p was down-regulated, and may be involved in the development of ALS, and therefore has potential as a reference for the diagnosis of ALS in the clinic.

  8. Magnetic immunoassay using CdSe/ZnS quantum dots as fluorescent probes to detect the level of DNA methyltransferase 1 in human serum sample

    Directory of Open Access Journals (Sweden)

    Yu F

    2018-01-01

    Full Text Available Fei Yu,1,* Ya-min Xiong,1,* Song-cheng Yu,1 Lei-liang He,1 Shan-shan Niu,1 Yu-ming Wu,1 Jie Liu,1 Ling-bo Qu,2 Li-e Liu,1 Yong-jun Wu1 1College of Public Health, 2College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, Henan, People’s Republic of China *These authors contributed equally to this work Background: DNA methyltransferase 1 (DNMT1, a dominant enzyme responsible for the transfer of a methyl group from the universal methyl donor to the 5-position of cytosine residues in DNA, is essential for mammalian development and closely related to cancer and a variety of age-related chronic diseases. DNMT1 has become a useful biomarker in early disease diagnosis and a potential therapeutic target in cancer therapy and drug development. However, till now, most of the studies on DNA methyltransferase (MTase detection have focused on the prokaryote MTase and its activity.Methods: A magnetic fluorescence-linked immunosorbent assay (FLISA using CdSe/ZnS quantum dots as fluorescent probes was proposed for the rapid and sensitive detection of the DNMT1 level in this study. Key factors that affect the precision and accuracy of the determination of DNMT1 were optimized.Results: Under the optimal conditions, the limit of detection was 0.1 ng/mL, the linear range was 0.1–1,500 ng/mL, the recovery was 91.67%–106.50%, and the relative standard deviations of intra- and inter-assays were respectively 5.45%–11.29% and 7.03%–11.25%. The cross-reactivity rates with DNA methyltransferases 3a and 3b were only 4.0% and 9.4%, respectively. Furthermore, FLISA was successfully used to detect the levels of DNMT1 in human serum samples, and compared with commercial enzyme-linked immunosorbent assay (ELISA kits. The results revealed that there was a good correlation between FLISA and commercial ELISA kits (correlation coefficient r=0.866, p=0.001. The linear scope of FLISA was broader than ELISA, and the measurement time was much shorter

  9. 77 FR 22561 - Drawn Stainless Steel Sinks From the People's Republic of China: Correction to Notice of...

    Science.gov (United States)

    2012-04-16

    ... multiple drawn bowls, with or without drain boards, whether finished or unfinished, regardless of type of... vertical corners to form the bowls. Stainless steel sinks with fabricated bowls may sometimes be referred...

  10. Diagnostic value and timing of serum antichlamidial antibody level evaluation during infertility workup among infertile women in whom tubal factor was detected with diagnostic laparoscopy

    Directory of Open Access Journals (Sweden)

    Serkan Kahyaoğlu

    2012-03-01

    Full Text Available OBJECTIVES: With normal hysterosalpingography (HSG results, selecting suitable candidates for the laparoscopic treatment of probable pelvic adhesions following previous pelvic inflammatory disease, it would be wise to investigate serum antibody screening against chlamidia trachomatis. It is worth to evaluate whether it is useful to detect a negative antichlamidial antibody disease for cancelling laparoscopy for a while with abnormal HSG findings. These two subjects have been investigated in study. MATERIAL AND METHODS: For detecting diagnostic value of serum antichlamidial antibody, in our infertility clinic, postoperative blood samples of 80 patients who were hospitalized for diagnostic laparoscopy to investigate infertility ethiology between May 2004 and November 2005 have been tested with microelisa method for antichlamidial IgM and IgG antibodies. HSG films of the patients performed at least one year were evaluated. Venous blood was drawn from these patients during postoperative early period for studying serum IgM and IgG antibodies of chlamidia trachomatis and the results were compared with operative findings. RESULTS: According to the antichlamidial antibody levels 60 (75% patients have not been infected with chlamidia and 20 (25% patients have been infected previously. When the patients were divided to two groups; normal and abnormal; based on preoperative HSG films; 18 (30% of the 60 patients with abnormal HSG films and 2 (10% of the 20 patients with normal HSG films had positive antichlamidial antibody levels respectively. CONCLUSION: The relationship between chlamidia trachomatis infection and tubal infertility has been demonstrated among 85% of patients with positive antichlamidial antibody levels and 46.7% of patients with negative levels who had tubal passage defects detected during diagnostic laparoscopy.

  11. Non-invasive optical detection of HBV based on serum surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Zheng, Zuci; Wang, Qiwen; Weng, Cuncheng; Lin, Xueliang; Lin, Yao; Feng, Shangyuan

    2016-10-01

    An optical method of surface-enhanced Raman spectroscopy (SERS) was developed for non-invasive detection of hepatitis B surface virus (HBV). Hepatitis B virus surface antigen (HBsAg) is an established serological marker that is routinely used for the diagnosis of acute or chronic hepatitis B virus(HBV) infection. Utilizing SERS to analyze blood serum for detecting HBV has not been reported in previous literature. SERS measurements were performed on two groups of serum samples: one group for 50 HBV patients and the other group for 50 healthy volunteers. Blood serum samples are collected from healthy control subjects and patients diagnosed with HBV. Furthermore, principal components analysis (PCA) combined with linear discriminant analysis (LDA) were employed to differentiate HBV patients from healthy volunteer and achieved sensitivity of 80.0% and specificity of 74.0%. This exploratory work demonstrates that SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of HBV.

  12. Determinants of brain-derived neurotrophic factor (BDNF) in umbilical cord and maternal serum.

    Science.gov (United States)

    Flöck, A; Weber, S K; Ferrari, N; Fietz, C; Graf, C; Fimmers, R; Gembruch, U; Merz, W M

    2016-01-01

    Brain-derived neurotrophic factor (BDNF) plays a fundamental role in brain development; additionally, it is involved in various aspects of cerebral function, including neurodegenerative and psychiatric diseases. Involvement of BDNF in parturition has not been investigated. The aim of our study was to analyze determinants of umbilical cord BDNF (UC-BDNF) concentrations of healthy, term newborns and their respective mothers. This cross-sectional prospective study was performed at a tertiary referral center. Maternal venous blood samples were taken on admission to labor ward; newborn venous blood samples were drawn from the umbilical cord (UC), before delivery of the placenta. Analysis was performed with a commercially available immunoassay. Univariate analyses and stepwise multivariate regression models were applied. 120 patients were recruited. UC-BDNF levels were lower than maternal serum concentrations (median 641 ng/mL, IQR 506 vs. median 780 ng/mL, IQR 602). Correlation between UC- and maternal BDNF was low (R=0.251, p=0.01). In univariate analysis, mode of delivery (MoD), gestational age (GA), body mass index at delivery, and gestational diabetes were determinants of UC-BDNF (MoD and smoking for maternal BDNF, respectively). Stepwise multivariate regression analysis revealed a model with MoD and GA as determinants for UC-BDNF (MoD for maternal BDNF). MoD and GA at delivery are determinants of circulating BDNF in the mother and newborn. We hypothesize that BDNF, like other neuroendocrine factors, is involved in the neuroendocrine cascade of delivery. Timing and mode of delivery may exert BDNF-induced effects on the cerebral function of newborns and their mothers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Optimal Fasting Time before Measurement of Serum Triglyceride Levels in Healthy Volunteers.

    Science.gov (United States)

    Pongsuthana, Surapun; Tivatunsakul, Naris

    2016-02-01

    Coronary heart disease is a major public health problem. Elevated triglyceride levels are a risk factor for atherosclerosis and coronary heart disease. Food intake interferes with the measurement of serum triglyceride levels, and in previous studies, fasting for 12 hours was recommended before blood sampling. In real-world practice, long fasting times cause patient discomfort and poor compliance, and the present study was, therefore, designed to determine the appropriate fasting time prior to measuring serum triglyceride levels. To determine the appropriate fasting time before measuring serum triglyceride levels. This was a pilot study performed using healthy volunteers aged between 20 and 30 years old from November 2013 to December 2013 at Rajavithi Hospital. The first blood sample was measured in the morning after fasting over 12 hours. The subjects then took their regular breakfast, after which they fasted for 8 hours. Blood samples were taken 6 and 8 hours later and sent to the laboratory for measurement of serum triglyceride levels. 40 volunteers, of whom 25 were female, were enrolled. Their mean age was 25.9 ± 2.81 years old, and their mean weight, height, and body mass index were 61.5 ± 12.5 kg, 167.2 ± 8.3 cm and 21.84 ± 3.1 kg/m2, respectively. Mean fasting serum triglyceride level at 12 hours was 80.23 ± 36.33 mg/dl, at 6 hours it was 110.65 ± 73.45 mg/dl, and at 8 hours it was 75.62 ± 46.81 mg/dl. The group fasting for 12 hours had significantly lower serum triglyceride levels than the group fasting for 6 hours (p-value = 0.003), but no significant difference was found between the group fasting for 12 hours and the one fasting for 8 hours (p-value = 0.493). The present study showed no significant difference in triglyceride levels in patients who had fasted or 8 hours and those who had done so for 12 hours. Fasting for only 8 hours before measurement of serum triglyceride may be sufficient.

  14. Headspace Solid Phase Micro Extraction Gas Chromatographic Determination of Fenthion in Human Serum

    Directory of Open Access Journals (Sweden)

    Kyriaki Machera

    2008-05-01

    Full Text Available A simple and effective analytical procedure was developed for the determination of fenthion residues in human serum samples. The sample treatment was performed using the headspace solid-phase micro extraction with polyacrylate fiber, which has the advantage to require low amount of serum (1 mL without tedious pre-treatment. The quantification of fenthion was carried out by gas chromatography-mass spectrometry and the recoveries ranged from 79 to 104% at two spiking levels for 6 replicates. Detection and quantification limits were calculated as 1.51 and 4.54 ng/mL of serum respectively. Two fenthion metabolites − fenoxon and fenthion–sulfoxide − were also identified.

  15. Antinuclear, Cytoskeletal, Antineuronal Antibodies in the Serum Samples of Children with Tic Disorders and Obsessive Compulsive Disorders

    Directory of Open Access Journals (Sweden)

    Işık Görker

    2011-11-01

    Full Text Available streptococcus infections in the development of tic and obsessive compulsive disorders (OCD is controversial. The autoimmune hypothesis states that during infection, formation of autoantibodies leads to an autoimmune disorder, which in turn results in movement disorders, tic disorders and/or OCD. In order to test this hypothesis, we assayed these antibodies in children and adolescents diagnosed with tic disorders and/or OCD.Material and Methods: Children and adolescents who were diagnosed with either tic disorders or OCD according to DSM-IV criteria (n=28, were compared with healthy controls (n=15 having similar age and gender characteristics. Regardless of a streptococcus infection history, serum samples of all patients and controls underwent antinuclear, cytoskeletal, and antineuronal antibody assay using indirect immunofluorescence.Results: The rates of antinuclear antibody positivity were 21% and 20% in the patient and control groups respectively (p>0.05. Antineuronal antibody was positive in 2 (7% of 28 patients versus in 1 (6% of 15 controls (p>0.05.Conclusion: These results suggest that such antibodies may not be involved in the pathogenesis of tic disorders/OCD.

  16. Spectrophotometric determination of dopamine hydrochloride in pharmaceutical, banana, urine and serum samples by potassium ferricyanide-Fe(III).

    Science.gov (United States)

    Guo, Li; Zhang, Yan; Li, Quanmin

    2009-12-01

    In the present work, we developed a simple, sensitive and inexpensive method to determine dopamine hydrochloride using potassium ferricyanide-Fe(III) by spectrophotometry. The results show that Fe(III) is deoxidized to Fe(II) by dopamine hydrochloride at pH 4.0, and then Fe(II) reacts with potassium ferricyanide to form a soluble prussian blue (KFe(III)[Fe(II)(CN)6]). The absorbance of this product was monitored over time using a spectrophotometer at an absorption maximum of 735 nm, and the amount of dopamine hydrochloride could be calculated based on the absorbance. A good linear relationship of the concentration of dopamine hydrochloride versus absorbance was observed, and a linear regression equation of A = 0.022 + 0.16921C (microg mL(-1)) was obtained. Moreover, the apparent molar absorption coefficient for the indirect determination of dopamine hydrochloride was 3.2 x 10(4) L mol(-1) cm(-1). This described method has been used to determine dopamine hydrochloride in pharmaceutical, banana, urine and serum samples with satisfactory results.

  17. Fertilizer drawn forward osmosis process for sustainable water reuse to grow hydroponic lettuce using commercial nutrient solution

    KAUST Repository

    Chekli, Laura; Eun Kim, Jung; El Saliby, Ibrahim; Kim, Youngjin; Phuntsho, Sherub; Li, Sheng; Ghaffour, NorEddine; Leiknes, TorOve; Kyong Shon, Ho

    2017-01-01

    This study investigated the sustainable reuse of wastewater using fertilizer drawn forward osmosis (FDFO) process through osmotic dilution of commercial nutrient solution for hydroponics, a widely used technique for growing plants without soil

  18. Significance of serum and bile tumor markers in the diagnostic approach of patients with malignant pancreatobiliary disease.

    Science.gov (United States)

    Natsios, Athanasios; Vezakis, Antonios; Kaparos, Georgios; Fragulidis, Georgios; Karakostas, Nikolaos; Kouskouni, Evangelia; Logothetis, Emmanouil; Polydorou, Andreas

    2015-01-01

    Serum and bile tumor markers are under intense scrutiny for the diagnosis of malignant disease. The purpose of our study was to report the usefulness of serum and bile tumor markers for the discrimination between benign and malignant pancreatobiliary diseases. Between March 2010 and May 2013, 95 patients with obstructive jaundice or history of biliary obstruction, were included in the study. During ERCP, bile samples were obtained for measurement of tumor markers CEA, CA19- 9, CA125, CA72-4 and CA242. Serum samples were taken before ERCP for the same measurements. The patients were divided into two groups: patients with malignant disease and patients with benign disease. Serum tumor marker levels were significantly higher in patients with malignant disease. Serum CA242 and CA19-9 exhibited the highest diagnostic accuracy (76.8% and 73.7%, respectively). CA125 and CA72-4 levels in bile samples were significantly higher in patients with malignant disease. Bile CA125, CEA and CA72-4 achieved the best diagnostic accuracy (69, 65 and 65), respectively). The combined detection of CA19-9, CA242 in serum and CA125, CA72-4 in bile along with total bilirubin levels, showed the best diagnostic accuracy (81%). Serum and bile tumor markers, when studied alone, lack the diagnostic yield to discriminate benign from malignant pancreatobiliary diseases. In cases of diagnostic dilemmas the combination of serum and bile markers might be helpful.

  19. Serum auto-antibody testing for early diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Parvez, S.

    2012-01-01

    The aim of this thesis is generate prototype-tests suitable for randomized prospective validation of auto-antibody based diagnostic testing using serum samples. Tumours can stimulate the production of auto-antibodies against autologous cellular proteins known as TAAs (tumour associated antigens). This discovery has lead to a possibility of using the auto-antibodies as serological tools for the early diagnosis and management of breast cancer. The recombinant proteins expressed by the SEREX clones, identified from screenings of brain and lung tumour, were used for the production of the protein microarrays and macroarrays. The protein microarrays showed better correlation between the replicates of the serum samples used. The optimized protocols were used for the subsequent experiments. A sizable panel of 642 clone-proteins was selected by marker-screening on protein macroarrays with 38000 clones. These 642 clone-proteins were used to generate protein microarrays that differentiated serum samples from breast cancer patients and controls. Antigenic peptide motifs were identified by in-silico analysis of 642 clone-proteins and peptide arrays were generated using synthetically generated peptides. Comparative studies between protein microarrays and peptide microarrays were done using breast cancer and healthy control samples. Simultaneously, SEREX strategy was used for the identification of the immunogenic TAAs. I identified 192 cDNA expression clones derived from breast cancer tissue samples and the selection was done using breast cancer sera. The genes corresponding to these clones were found over-represented for the pathways that are known to be associated with cancers. These genes showed typical features of TAAs, like over-expression, mutations and fusion genes. (author)

  20. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  1. First-Trimester Serum Acylcarnitine Levels to Predict Preeclampsia: A Metabolomics Approach

    Directory of Open Access Journals (Sweden)

    Maria P. H. Koster

    2015-01-01

    Full Text Available Objective. To expand the search for preeclampsia (PE metabolomics biomarkers through the analysis of acylcarnitines in first-trimester maternal serum. Methods. This was a nested case-control study using serum from pregnant women, drawn between 8 and 14 weeks of gestational age. Metabolites were measured using an UPLC-MS/MS based method. Concentrations were compared between controls (n=500 and early-onset- (EO- PE (n=68 or late-onset- (LO- PE (n=99 women. Metabolites with a false discovery rate <10% for both EO-PE and LO-PE were selected and added to prediction models based on maternal characteristics (MC, mean arterial pressure (MAP, and previously established biomarkers (PAPPA, PLGF, and taurine. Results. Twelve metabolites were significantly different between EO-PE women and controls, with effect levels between −18% and 29%. For LO-PE, 11 metabolites were significantly different with effect sizes between −8% and 24%. Nine metabolites were significantly different for both comparisons. The best prediction model for EO-PE consisted of MC, MAP, PAPPA, PLGF, taurine, and stearoylcarnitine (AUC = 0.784. The best prediction model for LO-PE consisted of MC, MAP, PAPPA, PLGF, and stearoylcarnitine (AUC = 0.700. Conclusion. This study identified stearoylcarnitine as a novel metabolomics biomarker for EO-PE and LO-PE. Nevertheless, metabolomics-based assays for predicting PE are not yet suitable for clinical implementation.

  2. Pyridoxal 5'-phosphate, pyridoxal, and 4-pyridoxic acid in the paired serum and cerebrospinal fluid of children.

    Science.gov (United States)

    Akiyama, Tomoyuki; Hayashi, Yumiko; Hanaoka, Yoshiyuki; Shibata, Takashi; Akiyama, Mari; Tsuchiya, Hiroki; Yamaguchi, Tokito; Kobayashi, Katsuhiro

    2017-09-01

    We quantified pyridoxal 5'-phosphate (PLP), pyridoxal (PL), and 4-pyridoxic acid (PA) in paired serum and cerebrospinal fluid (CSF) samples from children and investigated the effect of age on the concentrations and CSF-to-serum ratios of these vitamers. Serum and CSF samples prospectively collected from 49 pediatric patients were analyzed. PLP, PL, and PA were measured using high-performance liquid chromatography with fluorescence detection, using pre-column derivatization by semicarbazide. Effects of age on these vitamers, the PLP-to-PL ratio, CSF-to-serum PLP ratio, and CSF-to-serum PL ratio were evaluated using correlation analysis. The PLP, PL, and PA concentrations in the serum and CSF were higher at younger ages, except for CSF PA concentrations that were mostly below the limit of detection (<1.2nmol/l). The PLP-to-PL ratios in the serum and CSF correlated positively with age. The CSF-to-serum PLP ratio and CSF-to-serum PL ratio were independent of age. Age-related changes in PLP, PL, and PA in serum and in CSF from pediatric patients and CSF-to-serum ratios of PLP and PL demonstrated in this study will provide valuable information for evaluating PLP supply to the central nervous system from the peripheral blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Sampling Assumptions Affect Use of Indirect Negative Evidence in Language Learning.

    Directory of Open Access Journals (Sweden)

    Anne Hsu

    Full Text Available A classic debate in cognitive science revolves around understanding how children learn complex linguistic patterns, such as restrictions on verb alternations and contractions, without negative evidence. Recently, probabilistic models of language learning have been applied to this problem, framing it as a statistical inference from a random sample of sentences. These probabilistic models predict that learners should be sensitive to the way in which sentences are sampled. There are two main types of sampling assumptions that can operate in language learning: strong and weak sampling. Strong sampling, as assumed by probabilistic models, assumes the learning input is drawn from a distribution of grammatical samples from the underlying language and aims to learn this distribution. Thus, under strong sampling, the absence of a sentence construction from the input provides evidence that it has low or zero probability of grammaticality. Weak sampling does not make assumptions about the distribution from which the input is drawn, and thus the absence of a construction from the input as not used as evidence of its ungrammaticality. We demonstrate in a series of artificial language learning experiments that adults can produce behavior consistent with both sets of sampling assumptions, depending on how the learning problem is presented. These results suggest that people use information about the way in which linguistic input is sampled to guide their learning.

  4. Sampling Assumptions Affect Use of Indirect Negative Evidence in Language Learning

    Science.gov (United States)

    2016-01-01

    A classic debate in cognitive science revolves around understanding how children learn complex linguistic patterns, such as restrictions on verb alternations and contractions, without negative evidence. Recently, probabilistic models of language learning have been applied to this problem, framing it as a statistical inference from a random sample of sentences. These probabilistic models predict that learners should be sensitive to the way in which sentences are sampled. There are two main types of sampling assumptions that can operate in language learning: strong and weak sampling. Strong sampling, as assumed by probabilistic models, assumes the learning input is drawn from a distribution of grammatical samples from the underlying language and aims to learn this distribution. Thus, under strong sampling, the absence of a sentence construction from the input provides evidence that it has low or zero probability of grammaticality. Weak sampling does not make assumptions about the distribution from which the input is drawn, and thus the absence of a construction from the input as not used as evidence of its ungrammaticality. We demonstrate in a series of artificial language learning experiments that adults can produce behavior consistent with both sets of sampling assumptions, depending on how the learning problem is presented. These results suggest that people use information about the way in which linguistic input is sampled to guide their learning. PMID:27310576

  5. Comparison of serum fractionation methods by data independent label-free proteomics

    Directory of Open Access Journals (Sweden)

    D. Baiwir

    2015-12-01

    Full Text Available Off-line sample prefractionations applied prior to biomarker discovery proteomics are options to enable more protein identifications and detect low-abundance proteins. This work compared five commercial methods efficiency to raw serum analysis using label-free proteomics. The variability of the protein quantities determined for each process was similar to the unprefractionated serum. A 49% increase in protein identifications and 12.2% of reliable quantification were obtained. A 61 times lower limit of protein quantitation was reached compared to protein concentrations observed in raw serum. The concentrations of detected proteins were confronted to estimated reference values.

  6. Collagen derived serum markers in carcinoma of the prostate

    DEFF Research Database (Denmark)

    Rudnicki, M; Jensen, L T; Iversen, P

    1995-01-01

    Three new collagen markers deriving from the collagenous matrix, e.g. carboxyterminal propeptide of type I procollagen (PICP), carboxy-terminal pyridinoline cross-linked telopeptide of type I collagen (ICTP), and aminoterminal propeptide of type III procollagen (PIIINP) were used for the diagnose...... of prostatic bone metastases. Blood samples were obtained prior to biopsy or TURP. Serum PICP, PIIINP and ICTP were measured with commercial available RIAs and PSA by IRMA. Serum PSA was increased in patients with local prostatic cancer compared with patients with hyperplasia (p

  7. Metabolic Footprinting of Fermented Milk Consumption in Serum of Healthy Men

    Science.gov (United States)

    Pimentel, Grégory; Burton, Kathryn J; von Ah, Ueli; Bütikofer, Ueli; Pralong, François P; Vionnet, Nathalie; Portmann, Reto; Vergères, Guy

    2018-01-01

    Abstract Background Fermentation is a widely used method of natural food preservation that has consequences on the nutritional value of the transformed food. Fermented dairy products are increasingly investigated in view of their ability to exert health benefits beyond their nutritional qualities. Objective To explore the mechanisms underpinning the health benefits of fermented dairy intake, the present study followed the effects of milk fermentation, from changes in the product metabolome to consequences on the human serum metabolome after its ingestion. Methods A randomized crossover study design was conducted in 14 healthy men [mean age: 24.6 y; mean body mass index (in kg/m2): 21.8]. At the beginning of each test phase, serum samples were taken 6 h postprandially after the ingestion of 800 g of a nonfermented milk or a probiotic yogurt. During the 2-wk test phases, subjects consumed 400 g of the assigned test product daily (200 g, 2 times/d). Serum samples were taken from fasting participants at the end of each test phase. The serum metabolome was assessed through the use of LC-MS–based untargeted metabolomics. Results Postprandial serum metabolomes after milk or yogurt intake could be differentiated [orthogonal projections to latent structures discriminant analysis (OPLS-DA) Q2 = 0.74]. Yogurt intake was characterized by higher concentrations of 7 free amino acids (including proline, P = 0.03), reduced concentrations of 5 bile acids (including glycocholic acid, P = 0.04), and modulation of 4 indole derivative compounds (including indole lactic acid, P = 0.01). Fasting serum samples after 2 wk of daily intake of milk or yogurt could also be differentiated based on their metabolic profiles (OPLS-DA Q2 = 0.56) and were discussed in light of the postprandial results. Conclusion Metabolic pathways related to amino acids, indole derivatives, and bile acids were modulated in healthy men by the intake of yogurt. Further investigation to explore novel

  8. Preparation of the low molecular weight serum proteome for mass spectrometry analysis.

    Science.gov (United States)

    Waybright, Timothy J; Chan, King C; Veenstra, Timothy D; Xiao, Zhen

    2013-01-01

    The discovery of viable biomarkers or indicators of disease states is complicated by the inherent complexity of the chosen biological specimen. Every sample, whether it is serum, plasma, urine, tissue, cells, or a host of others, contains thousands of large and small components, each interacting in multiple ways. The need to concentrate on a group of these components to narrow the focus on a potential biomarker candidate becomes, out of necessity, a priority, especially in the search for immune-related low molecular weight serum biomarkers. One such method in the field of proteomics is to divide the sample proteome into groups based on the size of the protein, analyze each group, and mine the data for statistically significant items. This chapter details a portion of this method, concentrating on a method for fractionating and analyzing the low molecular weight proteome of human serum.

  9. Reproducibility of serum protein profiling by systematic assessment using solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry

    DEFF Research Database (Denmark)

    Callesen, Anne K; Christensen, René Depont; Madsen, Jonna S

    2008-01-01

    for serum protein profiling we investigated a range of sample preparation techniques and developed a statistical method based on repeated analyses for evaluation of protein-profiling performance of MALDI MS. Two different solid-phase extraction (SPE) methods were investigated, namely custom......Protein profiling of human serum by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is potentially a new diagnostic tool for early detection of human diseases, including cancer. Sample preparation is a key issue in MALDI MS and the analysis of complex samples such as serum......-made microcolumns and commercially available magnetic beads. Using these two methods, nineteen different sample preparation methods for serum profiling by MALDI MS were systematically tested with regard to matrix selection, stationary phase, selectivity, and reproducibility. Microcolumns were tested with regard...

  10. Development and application of a fluorescence protein microarray for detecting serum alpha-fetoprotein in patients with hepatocellular carcinoma.

    Science.gov (United States)

    Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong; Li, Ning

    2016-12-01

    Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC ( n = 65) and healthy control subjects ( n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC.

  11. Assessing the removal of organic micro-pollutants from anaerobic membrane bioreactor effluent by fertilizer-drawn forward osmosis

    KAUST Repository

    Kim, Youngjin; Li, Sheng; Chekli, Laura; Woo, Yun Chul; Wei, Chunhai; Phuntsho, Sherub; Ghaffour, NorEddine; Leiknes, TorOve; Shon, Ho Kyong

    2017-01-01

    In this study, the behavior of organic micro-pollutants (OMPs) transport including membrane fouling was assessed in fertilizer-drawn forward osmosis (FDFO) during treatment of the anaerobic membrane bioreactor (AnMBR) effluent. The flux decline

  12. Norm Block Sample Sizes: A Review of 17 Individually Administered Intelligence Tests

    Science.gov (United States)

    Norfolk, Philip A.; Farmer, Ryan L.; Floyd, Randy G.; Woods, Isaac L.; Hawkins, Haley K.; Irby, Sarah M.

    2015-01-01

    The representativeness, recency, and size of norm samples strongly influence the accuracy of inferences drawn from their scores. Inadequate norm samples may lead to inflated or deflated scores for individuals and poorer prediction of developmental and academic outcomes. The purpose of this study was to apply Kranzler and Floyd's method for…

  13. Effect of Camel Milk's Supplementation on Serum Glucose Levels ...

    African Journals Online (AJOL)

    Keywords: Camel Milk, Serum glucose, Lipid profile, Diabetes. INTRODUCTION. Diabetes is ... all products of Randox Laboratories, Switzerland. Fresh camel milk samples .... Abbott, R.D., Wilson, P.W., Kannel, W.B. and. Castelli, W.P. (1988).

  14. The Impact of Anxious and Calm Emotional States on Color Usage in Pre-Drawn Mandalas

    Science.gov (United States)

    Kersten, Andrea; van der Vennet, Renee

    2010-01-01

    The purpose of this single-subject experiment was to test whether a link exists between emotional state and color usage in a common art therapy technique. The researchers hypothesized that when coloring a pre-drawn mandala, participants would choose warm colors when they were anxious and cool colors when they were calm. The non-random sample…

  15. Quantitative determination of heparin levels in serum with microtiter plate-format optode

    International Nuclear Information System (INIS)

    Kim, Sung Bae; Kang, Tae Young; Cha, Geun Sig; Nam, Hakhyun

    2006-01-01

    A new assay method has been developed for the quantitative determination of heparin in serum using a microtiter plate-format optode (MPO). Heparin and proton in physiological sample are favorably co-extracted into the solvent polymeric optode membrane containing both cationic lipophilic additive, tridodecylmethyl ammonium chloride (TDMAC), and proton-selective ionophore, 3-hydroxy-4-(4-nitrophenylazo)-phenyloctadecanoate (ETH 2412), resulting in the absorbance change of the membrane to varying heparin levels. The optimized MPO composition contains low polymer-to-plasticizer ratio compared to those of conventional ion-selective optodes or electrodes, i.e., poly(vinyl chloride) (20.0)/dioctylsebacate (76.3)/ETH 2412 (1.7)/TDMAC (1.0) (wt.%): it resulted in a quantitative response to heparin from 0 to 15 unit/mL in serum with high sensitivity. The heparin-protamine titration on the MPO could provide rapid and precise determination of heparin. It was shown that the heparin levels in serum sample could be determined from the rate of absorbance change over time (ΔA/Δt); this method was more effective than the direct absorbance measurement in minimizing the interferences from color and turbidity of serum samples. MPO has been developed as a high throughput and convenient disposable sensing device, and may find a wide application in the determination of polyions and charged macromolecules

  16. Elevated Serum Level of Human Alkaline Phosphatase in Obesity

    International Nuclear Information System (INIS)

    Khan, A. R.; Awan, F. R.; Najam, S. S.; Islam, M.; Siddique, T.; Zain, M.

    2015-01-01

    Objective: To investigate a correlation between serum alkaline phosphatase level and body mass index in human subjects. Methods: The comparative cross-sectional study was carried out at the National Institute for Biotechnology and Genetic Engineering, Faisalabad, Pakistan, from April 2012 to June 2013. Blood serum alkaline phosphatase levels were estimated and the subjects were divided into three sub-groups on the basis of their body mass index: normal weight (<25kg/m2), overweight (25-27kg/m2) and obese (>27kg/m2) subjects. The serum samples were used for the estimation of clinically important biochemical parameters, using commercial kits on clinical chemistry analyser. Results: Of the 197 subjects, 97(49 percent) were obese and 100(51 percent) were non-obese. The serum alkaline phosphatase level increased in obese (214±6.4 IU/L) compared to the non-obese subjects (184.5±5 IU/L). Furthermore, a significant linear relationship (r=0.3;p-0.0001) was found between serum alkaline phosphatase and body mass index. Other biochemical variables were not correlated to the body mass index. Conclusion: Over activity and higher amounts of alkaline phosphatase were linked to the development of obesity. (author)

  17. Passive immunity transfer and serum constituents of crossbred calves

    Directory of Open Access Journals (Sweden)

    Thaís G. Rocha

    2012-06-01

    Full Text Available Passive immunity transfer (PIT evaluation is an essential tool for the maintenance of healthy calves during the first months of life. Since lactation number and breed have been proven to influence immunoglobulin levels in colostrum, the aim of this study was to evaluate PIT from primiparous and multiparous Canchim cows to their calves. Blood samples were collected from the calves before colostrum intake and 1, 2, 7, 15 and 30 days thereafter, while colostrum samples from the cows were taken immediately after parturition. Activities of gamma-glutamyl transferase (GGT, alkaline phosphatase (ALP, and concentrations of total protein, albumin, globulins, immunoglobulin A (IgA, immunoglobulin G (IgG, total and ionized calcium, inorganic phosphorus, magnesium, sodium and potassium were evaluated in calves' serum and activities of GGT and ALP and concentrations of total protein, IgA and IgG were assessed in cow's colostrum whey. Immunoglobulins concentrations were evaluated by electrophoresis in polyacrylamide gels. Serum biochemistry evaluations revealed an increase in gamma-glutamyl transferase and alkaline phosphatase activities and in total protein, globulins, immunoglobulin A and immunoglobulin G levels in calves' serum after colostrum intake. Only total protein and light chain immunoglobulin G levels in colostrum whey were affected by the cows' lactation number. Phosphorus and magnesium levels in blood serum increased after colostrum intake, while sodium and potassium levels oscillated in the experimental period. PIT was influenced by the cows' lactation number but was efficient in both groups.

  18. 78 FR 13019 - Drawn Stainless Steel Sinks From the People's Republic of China: Investigation, Final Determination

    Science.gov (United States)

    2013-02-26

    ... single or multiple drawn bowls, with or without drain boards, whether finished or unfinished, regardless... Tube From the People's Republic of China, 77 FR 52683, 52686 (August 30, 2012). \\30\\ See Preliminary... Determination of Critical Circumstances, in Part: Light- Walled Rectangular Pipe and Tube from the People's...

  19. Aflatoxin B1-lysine adduct in dried blood spot samples of animals and humans.

    Science.gov (United States)

    Xue, Kathy S; Cai, Wenjie; Tang, Lili; Wang, Jia-Sheng

    2016-12-01

    Dried blood spots (DBS) were proposed as potentially viable method for exposure assessment of environmental toxicants in infant and young children. For this study, we validated an experimental protocol to quantify AFB 1 -lysine adduct in DBS samples of AFB 1 -treated F344 rats, as well as samples from human field study. Significant dose-response relationships in AFB 1 -lysine adduct formation were found in DBS samples of rats treated with single- and repeated-dose AFB 1 . AFB 1 -lysine levels in DBS samples were highly correlated with corresponding serum sample levels. The Person coefficients were 0.997 for the single-dose exposure, and 0.996 for the repeated-dose exposure. Levels of AFB 1 -lysine adduct had also good agreement between DBS and serum samples as shown by Bland-Altman plot analysis. For human field study samples (n = 36), a Pearson correlation coefficient of 0.784 was found between AFB 1 -lysine adduct levels of DBS and corresponding serum samples. Bland-Altman plots showed the distribution of the log differences between DBS and serum AFB 1 -lysine levels are within 95% confidence intervals. These results showed AFB 1 -lysine adduct levels in DBS cards and serum samples from animals and human samples are comparable, and the DBS technique and analytical protocol is a good means to assess AFB 1 exposure in infant and children populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Relationship between serum total magnesium and serum potassium ...

    African Journals Online (AJOL)

    Relationship between serum total magnesium and serum potassium in emergency surgical patients in a tertiary hospital in Ghana. Robert Djagbletey, Brenda Phillips, Frank Boni, Christian Owoo, Ebenezer Owusu-Darkwa, Papa Kobina Gyakye deGraft-Johnson, Alfred E. Yawson ...

  1. The effect of a non-denaturing detergent and a guanidinium-based inactivation agent on the viability of Ebola virus in mock clinical serum samples.

    Science.gov (United States)

    Burton, J E; Easterbrook, L; Pitman, J; Anderson, D; Roddy, S; Bailey, D; Vipond, R; Bruce, C B; Roberts, A D

    2017-12-01

    The 2014 Ebola outbreak in West Africa required the rapid testing of clinical material for the presence of potentially high titre Ebola virus (EBOV). Safe, fast and effective methods for the inactivation of such clinical samples are required so that rapid diagnostic tests including downstream analysis by RT-qPCR or nucleotide sequencing can be carried out. One of the most commonly used guanidinium - based denaturing agents, AVL (Qiagen) has been shown to fully inactivate EBOV once ethanol is added, however this is not compatible with the use of automated nucleic acid extraction systems. Additional inactivation agents need to be identified that can be used in automated systems. A candidate inactivation agent is Triton X-100, a non-denaturing detergent that is frequently used in clinical nucleic acid extraction procedures and has previously been used for inactivation of EBOV. In this study the effect of 0.1% and 1.0% Triton X-100 (final concentration 0.08% and 0.8% respectively) alone and in combination with AVL on the viability of EBOV (10 6 TCID 50 /ml) spiked into commercially available pooled negative human serum was tested. The presence of viable EBOV in the treated samples was assessed by carrying out three serial passages of the samples in Vero E6 cells (37°C, 5% CO 2 , 1 week for each passage). At the end of each passage the cells were observed for evidence of cytopathic effect and samples were taken for rRT-PCR analysis for the presence of EBOV RNA. Before cell culture cytotoxic components of AVL and Triton X-100 were removed from the samples using size exclusion spin column technology or a hydrophobic adsorbent resin. The results of this study showed that EBOV spiked into human serum was not fully inactivated when treated with either 0.1% (v/v) Triton X-100 for 10 mins or 1.0% (v/v) Triton X-100 for 20 mins (final concentrations 0.08% and 0.8% Triton X-100 respectively). AVL alone also did not consistently provide complete inactivation. Samples treated

  2. Oral cancer screening: serum Raman spectroscopic approach

    Science.gov (United States)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  3. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    Science.gov (United States)

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  4. Day/night changes in serum S100B protein concentrations in acute paranoid schizophrenia.

    Science.gov (United States)

    Morera-Fumero, Armando L; Díaz-Mesa, Estefanía; Abreu-Gonzalez, Pedro; Fernandez-Lopez, Lourdes; Cejas-Mendez, Maria Del Rosario

    2017-04-03

    There are day/night and seasonal changes in biological markers such as melatonin and cortisol. Controversial changes in serum S100B protein levels have been described in schizophrenia. We aim studying whether serum S100B levels present day/night variations in schizophrenia patients and whether S100B levels are related to psychopathology. Sixty-five paranoid schizophrenic inpatients participated in the study. Psychopathology was assessed with the Positive and Negative Syndrome Scale (PANSS) at admission and discharge. Blood was drawn at 12:00 (midday) and 00:00 (midnight) hours at admission and discharge. Sixty-five healthy subjects matched by age, gender and season acted as control group. At admission and discharge patients had significantly higher serum S100B concentrations at midday and midnight than healthy subjects. At admission, patients showed a day/night variation of S100B levels, with higher S100B levels at 12:00 than at 00:00h (143.7±26.3pg/ml vs. 96.9±16.6pg/ml). This day/night difference was not present in the control group. Midday and midnight S100B at admission decreased when compared to S100B at discharge (midday, 143.7±26.3 vs. 83.0±12, midnight 96.9±16.6 vs. 68.6±14.5). There was a positive correlation between the PANSS positive subscale and S100B concentrations at admission. This correlation was not present at discharge. acute paranoid schizophrenia inpatients present a day/night change of S100B serum levels at admission that disappears at discharge. The correlation between serum S100B concentrations and the PANSS positive scores at admission as well as the decrease of S100B at discharge may be interpreted as an acute biological response to the clinical state of the patients. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Assessment of lectin and HILIC based enrichment protocols for characterization of serum glycoproteins by mass spectrometry

    DEFF Research Database (Denmark)

    Calvano, Cosima D; Zambonin, Carlo G; Jensen, Ole Nørregaard

    2008-01-01

    glycosylation profiles are associated with certain human ailments. Glycoprotein analysis by mass spectrometry of biological samples, such as blood serum, is hampered by sample complexity and the low concentration of the potentially informative glycopeptides and -proteins. We assessed the utility of lectin...... of 63 glycosylation sites in 38 proteins were identified by both methods, demonstrating distinct differences and complementarity. Serial application of custom-made microcolumns of mixed, immobilized lectins proved efficient for recovery and analysis of glycopeptides from serum samples of breast cancer...

  6. Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation.

    Science.gov (United States)

    Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2013-07-01

    Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American

  7. Determination of antibacterial flomoxef in serum by capillary electrophoresis.

    Science.gov (United States)

    Kitahashi, Toshihiro; Furuta, Itaru

    2003-04-01

    A determination method of flomoxef (FMOX) concentration in serum by capillary electrophoresis is developed. Serum samples are extracted with acetonitrile. After pretreatment, they are separated in a fused-silica capillary tube with a 25 mM borate buffer (pH 10.0) as a running buffer that contains 50mM sodium dodecyl sulfate. The FMOX and acetaminophen (internal standard) are detected by UV absorbance at 200 nm. Linearity (0-200 mg/L) is good, and the minimum limit of detection is 1.0 mg/L (S/N = 3). The relative standard deviations of intra- and interassay variability are 1.60-4.78% and 2.10-3.31%, respectively, and the recovery rate is 84-98%. This method can be used for determination of FMOX concentration in serum.

  8. Effect of oral contraceptive progestins on serum copper concentration

    DEFF Research Database (Denmark)

    Berg, Gabriele; Kohlmeier, L; Brenner, H

    1998-01-01

    OBJECTIVES: Recent epidemiologic studies have shown an increased mortality from cardiovascular diseases in people with higher serum copper levels. Even though higher serum copper concentration in women using oral contraceptives is well known, there is still uncertainty about the influence of newer...... progestin compounds in oral contraceptives on serum copper concentration. This issue is of particular interest in the light of recent findings of an increased risk of venous thromboembolism in users of oral contraceptives containing newer progestins like desogestrel compared to users of other oral...... contraceptives. DESIGN: Cross-sectional epidemiologic study. Examinations included a detailed questionnaire on medical history and lifestyle factors, a seven day food record, and blood samples. SETTING: National health and nutrition survey among healthy people living in private homes in West Germany in 1987...

  9. Vacuum-assisted breast biopsy of suspected mammographic breast diagnoses: predictive value of serum proteomic profile

    International Nuclear Information System (INIS)

    Schittulli, F.; Ventrella, V.

    2009-01-01

    The project planned a series of actions oriented to different scientific questions: to complete the prospective collection of serum samples for serum proteomic analysis according to SOPs needed for the Italy-USA program; the identification of different mammographic signs for prediction of histological diagnosis of breast lesions through mammotone; the analysis of relationship between serum proteomic profile and micro histology characteristics of breast lesions

  10. Metabonomic study of human serum in gallbladder cancer by 1H NMR spectroscopy

    International Nuclear Information System (INIS)

    Sonkar, Kanchan; Sinha, Neeraj; Behari, Anu; Kapoor, V.K.

    2012-01-01

    Gallbladder carcinoma (GBC) is one of the most lethal malignancies of upper gastrointestinal tract and it has the highest mortality rate in Chile and India. It has a very high incidence rates in northern India therefore it is also called as an Indian disease. There are several factors which play important role in development of gallbladder cancer including long-standing stones in gallbladder and alterations in composition of bile. Studies on gallstones and gallbladder tissues revealed that benign group can easily be discriminated from malignant group. Many proteomic studies have been performed for different cancers and several responsible serum protein markers have been identified but there is no such metabonomics study that shows the presence of any biomarker associated with gallbladder carcinoma. Identification of such biomarker would help immensely in the diagnostic of GBC. For this study we have collected blood samples (70; including patients from Chronic Cholecystitis (CC), XanthoGranulomatous Cholecystitis (XGC) and Gallbladder Cancer (GBC)) post-operatively (immediately after surgery) from patient undergoing cholecystectomy in Department of Surgical Gastroenterology, SGPGIMS. Control samples were also collected from 20 volunteers after 12 hrs of fasting. 4 ml of blood sample was collected and was allowed to clot in plastic tube for 30 min at room temperature in incubator. The serum was collected by centrifugation and samples were stored at -80 deg C till NMR experiments. 400 μL of serum was used for recording NMR spectra. NMR spectra were recorded at Bruker Avance 800 MHz spectrometer using CPMG pulse sequence with water presaturation. Control serum shows presence of various amino acids and low molecular weight metabolites. Detailed multivariate analysis along with markers found in serum associated with GBC will be presented. (author)

  11. Development of an electrothermal atomization laser-excited atomic fluorescence spectrometry procedure for direct measurements of arsenic in diluted serum.

    Science.gov (United States)

    Swart, D J; Simeonsson, J B

    1999-11-01

    A procedure for the direct determination of arsenic in diluted serum by electrothermal atomization laser-excited atomic fluorescence spectrometry (ETA-LEAFS) is reported. Laser radiation needed to excite As at 193.696 and 197.197 nm is generated as the second anti-Stokes stimulated Raman scattering output of a frequency-doubled dye laser operating near 230.5 and 235.5 nm, respectively. Two different LEAFS schemes have been utilized and provide limits of detection of 200-300 fg for As in aqueous standards. When measurements of serum samples diluted 1:10 with deionized water are performed, a stable background signal is observed that can be accounted for by taking measurements with the laser tuned off-wavelength. No As is detected in any of the bovine or human serum samples analyzed. Measurements of 100 pg/mL standard additions of As to a diluted bovine serum sample utilizing either inorganic or organic As species demonstrate a linear relationship of the fluorescence signal to As spike concentration, but exhibit a sensitivity of approximately half that observed in pure aqueous standards. The limit of detection for As in 1:10 diluted serum samples is 65 pg/mL or 650 fg absolute mass, which corresponds to 0.65 ng/mL As in undiluted serum. To our knowledge, the ETA-LEAFS procedure is currently the only one capable of directly measuring As in diluted serum at these levels.

  12. Elevated serum levels of Chromogranin A in hepatocellular carcinoma.

    Science.gov (United States)

    Biondi, Antonio; Malaguarnera, Giulia; Vacante, Marco; Berretta, Massimiliano; D'Agata, Velia; Malaguarnera, Michele; Basile, Francesco; Drago, Filippo; Bertino, Gaetano

    2012-01-01

    During the past three decades, the incidence of hepatocellular carcinoma in the United States has tripled. The neuroendocrine character has been observed in some tumor cells within some hepatocellular carcinoma nodules and elevated serum chromogranin A also been reported in patients with hepatocellular carcinoma. The aim of this work was to investigate the role of serum concentration of chromogranin A in patients with hepatocellular carcinoma at different stages. The study population consisted of 96 patients (63 males and 33 females age range 52-84) at their first hospital admission for hepatocellular carcinoma. The control group consisted of 35 volunteers (20 males and 15 females age range 50-80). The hepatocellular carcinoma patients were stratified according the Barcelona-Clinic Liver Cancer classification. Venous blood samples were collected before treatment from each patients before surgery, centrifuged to obtain serum samples and stored at -80° C until assayed. The chromogranin A serum levels were elevated (> 100 ng/ml) in 72/96 patients with hepatocellular carcinoma. The serum levels of chromogranin A were significantly correlated (p<0.05) with alpha-fetoprotein. In comparison with controls, the hepatocellular carcinoma patients showed a significant increase (p<0.001) vs controls. The chromogranin A levels in the Barcelona staging of hepatocellular carcinoma was higher in stage D compared to stage C (p<0.01), to stage B (p<0.001), and to stage A (p<0.001). Molecular markers, such as chromogranin A, could be very useful tools for hepatocellular carcinoma diagnosis. However the molecular classification should be incorporated into a staging scheme, which effectively separated patients into groups with homogeneous prognosis and response to treatment, and thus serves to aid in the selection of appropriate therapy.

  13. Experiments on the radioimmunological determination of the triiodothyronine binding capacity of human blood serum

    International Nuclear Information System (INIS)

    Traub, H.W.J.

    1980-01-01

    Bovine serum antibodies have been obtained from rabbits. Constant amounts of antibodies have been incubated with increasing amounts of antigens. The maximum value found for T 3 binding to the antigen-antibody complex was 66 μg RA/mg antigen. Human serum samples containing 0,05 ng 125 J-T 3 /μl were incubated with 600 μg RA, and the antigen was precipitated with 8,4 mg anti-RA. The mean value obtained for 30 enthyreotic test persons was a binding to RA of 7.9 +- 0,52% 125 J-T 3 . Comparative measurements of patient and standard serum samples shared only slight differences. This means that the measured data do not reflect the thyroid function. (orig./MG) [de

  14. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  15. TIMSS 2011 User Guide for the International Database. Supplement 4: TIMSS 2011 Sampling Stratification Information

    Science.gov (United States)

    Foy, Pierre, Ed.; Arora, Alka, Ed.; Stanco, Gabrielle M., Ed.

    2013-01-01

    This supplement contains documentation on the explicit and implicit stratification variables included in the TIMSS 2011 data files. The explicit strata are smaller sampling frames, created from the national sampling frames, from which national samples of schools were drawn. The implicit strata are nested within the explicit strata, and were used…

  16. Application of cloud point preconcentration and flame atomic absorption spectrometry for the determination of cadmium and zinc ions in urine, blood serum and water samples

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2013-01-01

    Full Text Available A simple, sensitive and selective cloud point extraction procedure is described for the preconcentration and atomic absorption spectrometric determination of Zn2+ and Cd2+ ions in water and biological samples, after complexation with 3,3',3",3'"-tetraindolyl (terephthaloyl dimethane (TTDM in basic medium, using Triton X-114 as nonionic surfactant. Detection limits of 3.0 and 2.0 µg L-1 and quantification limits 10.0 and 7.0 µg L-1were obtained for Zn2+ and Cd2+ ions, respectively. Relative standard deviation was 2.9 and 3.3, and enrichment factors 23.9 and 25.6, for Zn2+ and Cd2+ ions, respectively. The method enabled determination of low levels of Zn2+ and Cd2+ ions in urine, blood serum and water samples.

  17. Acute effect of copper exposure on serum biochemical characteristics of common carp (Cyprinus carpio L.

    Directory of Open Access Journals (Sweden)

    Melika Ghelichpour

    2014-07-01

    Full Text Available Effects of ambient copper was investigated on serum stress markers, sodium and enzyme levels in Common carp (Cyprinus carpio L. over a 14-d exposure period. Fish were exposed to 0, 25 and 100 μg L-1 copper (as copper sulfate and blood was sampled at 0, 3, 7 and 14 d after exposure. Serum profile was significantly affected by copper concentration, sampling time and their interaction. Increase in serum levels of cortisol, glucose, alanine aminotransferase and aspartate aminotransferase and decrease in serum sodium levels were observed in both copper-exposed groups, 3 d after copper exposure, which lasted until the end of the experiment. It is concluded that copper exposure causes stress response and sodium loss in common carp. Likewise alanine aminotransferase and aspartate aminotransferase increase after exposure which might be as results of either tissue damage or stress.

  18. SERUM IGF-I AND HORMONAL RESPONSES TO INCREMENTAL EXERCISE IN ATHLETES WITH AND WITHOUT LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Zebrowska

    2009-03-01

    Full Text Available We investigated the response of insulin-like growth factor (IGF- I, insulin-like growth factor binding protein-3 (IGFBP-3 and some hormones, i.e., testosterone (T, growth hormone (GH, cortisol (C, and insulin (I, to maximal exercise in road cyclists with and without diagnosed left ventricular hypertrophy. M-mode and two-dimensional Doppler echocardiography was performed in 30 professional male endurance athletes and a group of 14 healthy untrained subjects using a Hewlett-Packard Image Point HX ultrasound system with standard imaging transducers. Echocardiography and an incremental physical exercise test were performed during the competitive season. Venous blood samples were drawn before and immediately after the maximal cycling exercise test for determination of somatomedin and hormonal concentrations. The basal concentration of IGF-I was statistically higher (p < 0.05 in athletes with left ventricular muscle hypertrophy (LVH when compared to athletes with a normal upper limit of the left ventricular wall (LVN (p < 0.05 and to the control group (CG (p < 0.01. The IGF-I level increased significantly at maximal intensity of incremental exercise in CG (p < 0.01, LVN (p < 0.05 and LVH (p < 0.05 compared to respective values at rest. Long-term endurance training induced an increase in resting (p < 0.01 and post-exercise (p < 0.05 IGF-I/IGFBP-3 ratio in athletes with LVH compared to LVN. The testosterone (T level was lower in LVH at rest compared to LVN and CG groups (p < 0.05. These results indicate that resting serum IGF-I concentration were higher in trained subjects with LVH compared to athletes without LVH. Serum IGF- I/IGFBP-3 elevation at rest and after exercise might suggest that IGF-I act as a potent stimulant of left ventricular hypertrophy in chronically trained endurance athletes

  19. Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration.

    Science.gov (United States)

    Killilea, David W; Rohner, Fabian; Ghosh, Shibani; Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H; King, Janet C

    2017-06-01

    Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1-2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions.

  20. Thiazide increases serum calcium in anuric patients: the role of parathyroid hormone.

    Science.gov (United States)

    Vasco, Raquel F V; Reis, Eduardo T; Moyses, Rosa M A; Elias, Rosilene M

    2017-12-01

    We evaluated the effect of hydrochlorothiazide in a sample of anuric patients on hemodialysis and found an increase in serum calcium, which occurred only in those with parathyroid hormone >300 pg/ml. This finding highlights the extra-renal effect of this diuretic and a possible role of parathyroid hormone in the mechanism. Thiazide diuretics are commonly used in patients with chronic kidney disease to treat hypertension. Their effects on calcium and bone metabolism are not well established, once calciuria may not fully explain levels of calcium and parathyroid hormone (PTH) in this population. A previous study has suggested that thiazides require the presence of PTH as a permissive condition for its renal action. In anuric patients, however, the role of PTH, if any, in the thiazide effect is unknown. To assess thiazide extra renal effect on serum calcium and whether such an effect is reliant on PTH, hydrochlorothiazide (HCTZ) 100 mg was given orally once a day to a sample of 19 anuric patients on hemodialysis for 2 weeks. Laboratories' analyses were obtained in three phases: baseline, after diuretic use, and after a 2-week washout phase. We demonstrated that serum calcium (Ca) increased in ten patients (52.6%) after HCTZ use, returning to previous levels after the washout period. Out of the 19 patients, ten presented PTH ≥ 300 pg/ml, and Ca has increased in eight of them, whereas in the other nine patients with PTH < 300 pg/ml, serum Ca has increased only in two individuals (RR risk of increase Ca 3.9; p = 0.012). HCTZ was capable of increasing serum Ca in a sample of anuric patients on hemodialysis and seems this effect is highly dependent on PTH levels. Caution is required while interpreting this result, as the small sample size might implicate in a finding caused by chance.

  1. Correlation of Serum Magnesium with Serum Parathormone Levels in Patients on Regular Hemodialysis

    Directory of Open Access Journals (Sweden)

    Baradaran Azar

    2006-01-01

    Full Text Available Secondary hyperparathyroidism (SHPT is a common, important, and treatable complication of end-stage renal disease. This study was conducted to investigate the role of serum magnesium (Mg in regulating the secretion of parathyroid hormone (PTH by the parathyroid gland in patients on maintenance hemodialysis (HD. Pre-dialysis serum levels of calcium (Ca, phosphorus (P, Mg, alkaline phosphatase (ALP, intact serum PTH (iPTH, serum 25-hydroxy Vitamin D (25-OH Vit D and plasma bicarbonate (HCO3 were measured. The Urea Reduction Rate as well as duration and dosage of HD treatment were noted. Our study did not show any significant correlation between serum Mg levels and duration of HD treatment, levels of serum ALP, and plasma HCO3, Ca and P. An inverse correlation, albeit insignificant, was found between the serum Mg levels and iPTH (r=-0.30 p=0.079; also, a significant positive correlation was found between serum Mg levels and serum 25-OH Vit D levels (r= 0.40 p= 0.009. Our findings are in agreement with previous data, which suggest that factors other than serum Mg are more important in the regulation of PTH secretion in HD patients. A positive and strong association between serum Mg with 25-OH Vit D needs to be studied in greater detail.

  2. Combined experimental and statistical strategy for mass spectrometry based serum protein profiling for diagnosis of breast cancer

    DEFF Research Database (Denmark)

    Callesen, Anne Kjærgaard; Vach, Werner; Jørgensen, Per E

    2008-01-01

    it in a well-described breast cancer case-control study. A rigorous sample collection protocol ensured high quality specimen and reduced bias from preanalytical factors. Preoperative serum samples obtained from 48 breast cancer patients and 28 controls were used to generate MALDI MS protein profiles. A total...... and controls. A diagnostic rule based on these 72 mass values was constructed and exhibited a cross-validated sensitivity and specificity of approximately 85% for the detection of breast cancer. With this method, it was possible to distinguish early stage cancers from controls without major loss of sensitivity...... and specificity. We conclude that optimized serum sample handling and mass spectrometry data acquisition strategies in combination with statistical analysis provide a viable platform for serum protein profiling in cancer diagnosis....

  3. Serum testosterone levels in males are not associated with entrepreneurial behavior in two independent observational studies.

    Science.gov (United States)

    van der Loos, Matthijs J H M; Haring, Robin; Rietveld, Cornelius A; Baumeister, Sebastian E; Groenen, Patrick J F; Hofman, Albert; de Jong, Frank H; Koellinger, Philipp D; Kohlmann, Thomas; Nauck, Matthias A; Rivadeneira, Fernando; Uitterlinden, André G; van Rooij, Frank J A; Wallaschofski, Henri; Thurik, A Roy

    2013-07-02

    Previous research has suggested a positive association between testosterone (T) and entrepreneurial behavior in males. However, this evidence was found in a study with a small sample size and has not been replicated. In the present study, we aimed to verify this association using two large, independent, population-based samples of males. We tested the association of T with entrepreneurial behavior, operationalized as self-employment, using data from the Rotterdam Study (N=587) and the Study of Health in Pomerania (N=1697). Total testosterone (TT) and sex hormone-binding globulin (SHBG) were measured in the serum. Free testosterone (FT), non-SHBG-bound T (non-SHBG-T), and the TT/SHBG ratio were calculated and used as measures of bioactive serum T, in addition to TT adjusted for SHBG. Using logistic regression models, we found no significant associations between any of the serum T measures and self-employment in either of the samples. To our knowledge, this is the first large-scale study on the relationship between serum T and entrepreneurial behavior. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Prevalence of antileptospiral serum antibodies in dogs in Ireland

    Science.gov (United States)

    A total of 474 serum samples from client owned Irish dogs were tested for the presence of antibodies against serovars Canicola, Icterohaemorrhagiae, Bratislava, Autumnalis, Pomona, Altodouro, Grippotyphosa, Mozdok, Hardjobovis and Ballum. Six percent of dogs presented to veterinary practitioners for...

  5. Production of antiserum and development of radioimmunoassay for progesterone measurement in serum

    International Nuclear Information System (INIS)

    Abdalla, O.M; Abbas, S.H.

    2004-03-01

    The anti progesterone antibody was obtained by injection of local sudanese sheep (bevies arias) intramuscularly and subcutaneously using 11-a-hydroxy progesterone conjugated with bovine serum albumin and emulsified in friend's adjuvant. The blood samples collected one week after the 3 rd injection was tested for anti-progesterone antibodies. Different dilutions of antisera in Pbs containing 0.0.1 % BSA and 0.1 % Na N 3 (Ph 7.4) were made. Using these dilutions, polystyrene balls of 6.4 mm diameter were coated with a coating volume of 500 μ1/bead.The antibody dilution of 1/200000 was selected and used for assembling a kit to measure progesterone level in serum. Optimization of the assay condition resulted in the following recipes: Fifty μ1 of standard or Qc (Low, normal and high) from Bio Rad for 2 hours. The reaction medium aspirated, washed twice and read for 100 seconds in gamma counter. Assay validation tests including Linearity, recovery, reproducibility and comparability were done. In regards to linearity, the measured concentrations of progesterone in serum samples were plotted against the expected values. The correlation coefficient was 0.997 and a linear regression equation was Y=1.1019+0.9895 X. The mean recovery was 96.86% of the sample replicates ranged from 0.2% to 6%. between assay reproducibility was assessed fro the results obtained from 3 samples which were used for quality control in different assays. The results obtained were in the reference range and were close to each other. Comparison between local and American Dpc reagents for progesterone determination in serum showed high correlation high correlation where r 0.9492.(Author)

  6. Selection of suitable fertilizer draw solute for a novel fertilizer-drawn forward osmosis-anaerobic membrane bioreactor hybrid system

    KAUST Repository

    Kim, Youngjin; Chekli, Laura; Shim, Wang-Geun; Phuntsho, Sherub; Li, Sheng; Ghaffour, NorEddine; Leiknes, TorOve; Shon, Ho Kyong

    2016-01-01

    In this study, a protocol for selecting suitable fertilizer draw solute for anaerobic fertilizer-drawn forward osmosis membrane bioreactor (AnFDFOMBR) was proposed. Among eleven commercial fertilizer candidates, six fertilizers were screened further

  7. Serum telomerase levels in smokers and smokeless tobacco users as Maras powder.

    Science.gov (United States)

    Bozkuş, Fulsen; Atilla, Nurhan; Şimşek, Seçil; Kurutaş, Ergül; Samur, Anıl; Arpağ, Hüseyin; Kahraman, Hasan

    2017-09-01

    To the best of our knowledge, no previous study regarding the serum telomerase levels in Maras powder users (MPUs) has been founded. The aim of the current study was to investigate serum telomerase levels in smokers and MPUs. The study was carried out with 98 patients (36 MPUs, 32 smokers and 30 non-smokers). Blood samples were collected, and after having measured the serum telomerase and malondialdehyde (MDA) levels of the patients, comparison were made between the groups. It has been observed that the serum telomerase and MDA levels of smokers (pnon-smoker control subjects. In addition, the levels of serum telomerase and MDA were observed to be higher in the MPU group compared to those of the smoker group (psmokers. In this context, it may be useful to further measure and assess telomerase activity in such patients in order to better determine the harmful effects associated with these habits.

  8. On the radiolysis of desoxyribonucleic acid in presence of serum albumin

    International Nuclear Information System (INIS)

    Geiger, A.M.

    1984-01-01

    The experiments were carried out on the simple model of DNA-bovine serum albumin. The two substances were solved in 10 -2 M sodium phosphate buffer pH 7 in the ratio 1 : 10, which is about the natural ratio of nucleic acid to protein in the cell. The preparations were irradiated with various doses up to 1760 Gy, in the presence of air, nitrogen, or laughing gas. The irradiated samples were then separated over the gel sepharose CL-2B using 2 x 10 -2 M sodium phosphate buffer pH 7 with and without sodium dodecyl sulphate. Photometric measurement of the fractions was done using a wavelength of 260 nm. The protein content was determined with two different colorimetric techniques, after calibrating experiments defining the linear range. In order to determine the effect of the protein on the radiosensitivity of the DNA, samples without bovine serum albumin were irradiated in the three gaseous environments with 440 Gy. Incubation of the irradiated samples with SDS, and separation in the presence of SDS, revealed information on the covalent bonds forming between DNA and bovine serum albumin, whereas gel filtration without SDS yielded information also on non-covalent bonds. (orig./EF) [de

  9. Characterization of the serum metabolome following radiation treatment in patients with high-grade gliomas

    International Nuclear Information System (INIS)

    Mörén, Lina; Wibom, Carl; Bergström, Per; Johansson, Mikael; Antti, Henrik; Bergenheim, A. Tommy

    2016-01-01

    Glioblastomas progress rapidly making response evaluation using MRI insufficient since treatment effects are not detectable until months after initiation of treatment. Thus, there is a strong need for supplementary biomarkers that could provide reliable and early assessment of treatment efficacy. Analysis of alterations in the metabolome may be a source for identification of new biomarker patterns harboring predictive information. Ideally, the biomarkers should be found within an easily accessible compartment such as the blood. Using gas-chromatographic- time-of-flight-mass spectroscopy we have analyzed serum samples from 11 patients with glioblastoma during the initial phase of radiotherapy. Fasting serum samples were collected at admittance, on the same day as, but before first treatment and in the morning after the second and fifth dose of radiation. The acquired data was analyzed and evaluated by chemometrics based bioinformatics methods. Our findings were compared and discussed in relation to previous data from microdialysis in tumor tissue, i.e. the extracellular compartment, from the same patients. We found a significant change in metabolite pattern in serum comparing samples taken before radiotherapy to samples taken during early radiotherapy. In all, 68 metabolites were lowered in concentration following treatment while 16 metabolites were elevated in concentration. All detected and identified amino acids and fatty acids together with myo-inositol, creatinine, and urea were among the metabolites that decreased in concentration during treatment, while citric acid was among the metabolites that increased in concentration. Furthermore, when comparing results from the serum analysis with findings in tumor extracellular fluid we found a common change in metabolite patterns in both compartments on an individual patient level. On an individual metabolite level similar changes in ornithine, tyrosine and urea were detected. However, in serum, glutamine and

  10. Genetic regulation of serum phytosterol levels and risk of coronary artery disease.

    Science.gov (United States)

    Teupser, Daniel; Baber, Ronny; Ceglarek, Uta; Scholz, Markus; Illig, Thomas; Gieger, Christian; Holdt, Lesca M; Leichtle, Alexander; Greiser, Karin H; Huster, Dominik; Linsel-Nitschke, Patrick; Schäfer, Arne; Braund, Peter S; Tiret, Laurence; Stark, Klaus; Raaz-Schrauder, Dorette; Fiedler, Georg M; Wilfert, Wolfgang; Beutner, Frank; Gielen, Stephan; Grosshennig, Anika; König, Inke R; Lichtner, Peter; Heid, Iris M; Kluttig, Alexander; El Mokhtari, Nour E; Rubin, Diana; Ekici, Arif B; Reis, André; Garlichs, Christoph D; Hall, Alistair S; Matthes, Gert; Wittekind, Christian; Hengstenberg, Christian; Cambien, Francois; Schreiber, Stefan; Werdan, Karl; Meitinger, Thomas; Loeffler, Markus; Samani, Nilesh J; Erdmann, Jeanette; Wichmann, H-Erich; Schunkert, Heribert; Thiery, Joachim

    2010-08-01

    Phytosterols are plant-derived sterols that are taken up from food and can serve as biomarkers of cholesterol uptake. Serum levels are under tight genetic control. We used a genomic approach to study the molecular regulation of serum phytosterol levels and potential links to coronary artery disease (CAD). A genome-wide association study for serum phytosterols (campesterol, sitosterol, brassicasterol) was conducted in a population-based sample from KORA (Cooperative Research in the Region of Augsburg) (n=1495) with subsequent replication in 2 additional samples (n=1157 and n=1760). Replicated single-nucleotide polymorphisms (SNPs) were tested for association with premature CAD in a metaanalysis of 11 different samples comprising 13 764 CAD cases and 13 630 healthy controls. Genetic variants in the ATP-binding hemitransporter ABCG8 and at the blood group ABO locus were significantly associated with serum phytosterols. Effects in ABCG8 were independently related to SNPs rs4245791 and rs41360247 (combined P=1.6 x 10(-50) and 6.2 x 10(-25), respectively; n=4412). Serum campesterol was elevated 12% for each rs4245791 T-allele. The same allele was associated with 40% decreased hepatic ABCG8 mRNA expression (P=0.009). Effects at the ABO locus were related to SNP rs657152 (combined P=9.4x10(-13)). Alleles of ABCG8 and ABO associated with elevated phytosterol levels displayed significant associations with increased CAD risk (rs4245791 odds ratio, 1.10; 95% CI, 1.06 to 1.14; P=2.2 x 10(-6); rs657152 odds ratio, 1.13; 95% CI, 1.07 to 1.19; P=9.4 x 10(-6)), whereas alleles at ABCG8 associated with reduced phytosterol levels were associated with reduced CAD risk (rs41360247 odds ratio, 0.84; 95% CI, 0.78 to 0.91; P=1.3 x 10(-5)). Common variants in ABCG8 and ABO are strongly associated with serum phytosterol levels and show concordant and previously unknown associations with CAD.

  11. Physician-assisted dying: thoughts drawn from Albert Camus' writing.

    Science.gov (United States)

    Bozzaro, Claudia

    2018-03-20

    Physician-assisted dying (assisted suicide and euthanasia) is currently an intensely discussed topic in several countries. Despite differences in legislation and application, countries with end-of-life laws have similar eligibility criteria for assistance in dying: individuals must be in a hopeless situation and experience unbearable suffering. Hopelessness, as a basic aspect of the human condition, is a central topic in Albert Camus' philosophical work The Myth of Sisyphus, which addresses the question of suicide. Suffering in the face of a hopeless situation, and the way doctors approach this suffering, is the topic of his novel The Plague, which describes the story of a city confronted with a plague epidemic. In this paper, I draw philosophical and ethical conclusions about physician-assisted dying based on an analysis of central concepts in the work of Camus-specifically, those treated in The Myth of Sisyphus and The Plague. On the basis of my interpretation of Camus' work, I argue that hopelessness and unbearable suffering are useless as eligibility criteria for physician-assisted dying, given that they do not sufficiently elucidate where the line should be drawn between patients who should to be eligible for assistance and those who should not.

  12. Association of serum sparc with insulin resistance in type-2 diabetes mellitus

    International Nuclear Information System (INIS)

    Nadeem, K.; Ahmed, U.; Arif, H.

    2017-01-01

    Objective: To determine the association of serum SPARC with insulin resistance in type-2 diabetes. Study Design: Descriptive study. Place and Duration of Study: Physiology department and CREAM lab, Army medical college, Rawalpindi, in collaboration with Military Hospital Rawalpindi, from Feb 2016 to Oct 2016. Material and Methods: Sixty individuals were recruited in this descriptive study. Thirty diagnosed cases of type- 2 DM were included, while thirty age and gender matched healthy individuals were included as controls through non-probability purposive sampling. Controls were labelled as group A, while cases were labelled as group B. Patients with type-1 DM, type-2 DM on insulin therapy, hyperglycemic states other than DM and inflammatory disorders were excluded from the study. Data were collected after informed and written consent. Blood samples were withdrawn under strict aseptic measures and serum was stored at -20 degree C. Serum insulin levels and serum SPARC levels were analyzed by enzyme linked immunosorbent assay (ELISA). Insulin resistance was determined using homeostasis model assessment of insulin resistance (HOMA-IR), and its value >1.5 was considered significant. Results: Fasting insulin levels were significantly higher in group B as compared with group A, supporting the diagnosis of type-2 DM. HOMA-IR values were greater than 1.5 in group B, thus establishing significant insulin resistance. Serum SPARC levels were significantly higher in group B than group A (17.7 ± 1.14 vs 8.7 ± 1.08 ng/ml) with p-value<0.001. Serum SPARC levels showed positive correlation with fasting insulin levels and HOMA-IR values. Conclusion: Our study showed a positive correlation between serum SPARC levels and insulin resistance, which indicates that SPARC plays an important role in the development of insulin resistance in type-2 diabetes mellitus. (author)

  13. Direct microcomputer controlled determination of zinc in human serum by flow injection atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Nielsen, Bent; Jensen, Arne

    1986-01-01

    A procedure is described for the direct determination of zinc in human serum by fully automated, microcomputer controlled flow injection atomic absorption spectrometry (Fl-AAS). The Fl system is pumpless, using the negative pressure created by the nebuliser. It only consists of a three-way valve......, programmable from the microcomputer, to control the sample volume. No pre-treatment of the samples is necessary. The limit of detection is 0.14 mg l–1, and only small amounts of serum (

  14. Serum IgG antibody levels to periodontal microbiota are associated with incident Alzheimer disease.

    Directory of Open Access Journals (Sweden)

    James M Noble

    Full Text Available Periodontitis and Alzheimer disease (AD are associated with systemic inflammation. This research studied serum IgG to periodontal microbiota as possible predictors of incident AD.Using a case-cohort study design, 219 subjects (110 incident AD cases and 109 controls without incident cognitive impairment at last follow-up, matched on race-ethnicity, were drawn from the Washington Heights-Inwood Columbia Aging Project (WHICAP, a cohort of longitudinally followed northern Manhattan residents aged >65 years. Mean follow-up was five years (SD 2.6. In baseline sera, serum IgG levels were determined for bacteria known to be positively or negatively associated with periodontitis (Porphyromonas gingivalis, Tannerella forsythia, Actinobacillus actinomycetemcomitans Y4, Treponema denticola, Campylobacter rectus, Eubacterium nodatum, and Actinomyces naeslundii genospecies-2. In all analyses, we used antibody threshold levels shown to correlate with presence of moderate-severe periodontitis.Mean age was 72 years (SD 6.9 for controls, and 79 years (SD 4.6 for cases (p640 ng/ml, present in 10% of subjects was associated with increased risk of AD (HR = 2.0, 95%CI: 1.1-3.8. This association was stronger after adjusting for other significant titers (HR = 3.1, 95%CI: 1.5-6.4. In this model, high anti-E. nodatum IgG (>1755 ng/ml; 19% of subjects was associated with lower risk of AD (HR = 0.5, 95%CI: 0.2-0.9.Serum IgG levels to common periodontal microbiota are associated with risk for developing incident AD.

  15. B-type natriuretic peptide (BNP serum levels in rats after forced repeated swimming stress

    Directory of Open Access Journals (Sweden)

    Almira Hadžovic-Džuvo

    2011-02-01

    Full Text Available Aim To estimate the effects of forced repeated swimming stress on BNP serum levels in rats. Methods Adult male Wistar rats weighting between 280-330 g were divided into two groups: control group (n =8 and stress group (n =8. Rats in the stress group were exposed to forced swimming stress daily, for 7 days. The rats were forced to swim in plastic tanks (90 cm wide, 120 cm deep containing tap water (temperature ca. 25°C. The depth of water was 40 cm. Duration of each swimming session progressively increased from 10 minutes on the irst day to 40 minutes on days 6 and 7. Rats were sacriiced and blood was drawn from abdominal aorta for BNP analysis immediately after the last swimming session. B-type natriuretic serum level was determined by ELISA method using RAT BNP-32 kit (Phoenix Pharmaceutical Inc.. Results There was no statistically signiicant difference between mean BNP serum level in the stress group after the swimming period (0.81±0.14 ng/ml as compared to the unstressed group of rats (0.8 ±0.08ng/ml. After the swimming period mean body weight slightly decreased in the stress group in comparison with values before stress period (296.3 g vs.272.8 g, but this difference was not statistically signiicant. The stress period had no inluence on food intake in the stress rat group. Conclusion The workload consisting of 40-minutes long swimming session is not suficient to provoke BNP release from myocardium in rats.

  16. B-type natriuretic peptide (BNP) serum levels in rats after forced repeated swimming stress.

    Science.gov (United States)

    Hadzovic-Dzuvo, Almira; Valjevac, Amina; Avdagić, Nesina; Lepara, Orhan; Zaćiragić, Asija; Jadrić, Radivoj; Alajbegović, Jasmin; Prnjavorac, Besim

    2011-02-01

    To estimate the effects of forced repeated swimming stress on BNP serum levels in rats. Adult male Wistar rats weighting between 280-330 g were divided into two groups: control group (n = 8) and stress group (n = 8). Rats in the stress group were exposed to forced swimming stress daily, for 7 days. The rats were forced to swim in plastic tanks (90 cm wide, 120 cm deep) containing tap water (temperature ca. 25 degrees C). The depth of water was 40 cm. Duration of each swimming session progressively increased from 10 minutes on the first day to 40 minutes on days 6 and 7. Rats were sacrificed and blood was drawn from abdominal aorta for BNP analysis immediately after the last swimming session. B-type natriuretic serum level was determined by ELISA method using RAT BNP-32 kit (Phoenix Pharmaceutical Inc.). There was no statistically significant difference between mean BNP serum level in the stress group after the swimming period (0.81 +/- 0.14 ng/ml) as compared to the unstressed group of rats (0.8 +/- 0.08 ng/ml). After the swimming period mean body weight slightly decreased in the stress group in comparison with values before stress period (296.3 g vs. 272.8 g), but this difference was not statistically significant. The stress period had no influence on food intake in the stress rat group. The workload consisting of 40-minutes long swimming session is not sufficient to provoke BNP release from myocardium in rats.

  17. Detection and serotyping of dengue virus in serum samples by multiplex reverse transcriptase PCR-ligase detection reaction assay.

    Science.gov (United States)

    Das, S; Pingle, M R; Muñoz-Jordán, J; Rundell, M S; Rondini, S; Granger, K; Chang, G-J J; Kelly, E; Spier, E G; Larone, D; Spitzer, E; Barany, F; Golightly, L M

    2008-10-01

    The detection and successful typing of dengue virus (DENV) from patients with suspected dengue fever is important both for the diagnosis of the disease and for the implementation of epidemiologic control measures. A technique for the multiplex detection and typing of DENV serotypes 1 to 4 (DENV-1 to DENV-4) from clinical samples by PCR-ligase detection reaction (LDR) has been developed. A serotype-specific PCR amplifies the regions of genes C and E simultaneously. The two amplicons are targeted in a multiplex LDR, and the resultant fluorescently labeled ligation products are detected on a universal array. The assay was optimized using 38 DENV strains and was evaluated with 350 archived acute-phase serum samples. The sensitivity of the assay was 98.7%, and its specificity was 98.4%, relative to the results of real-time PCR. The detection threshold was 0.017 PFU for DENV-1, 0.004 PFU for DENV-2, 0.8 PFU for DENV-3, and 0.7 PFU for DENV-4. The assay is specific; it does not cross-react with the other flaviviruses tested (West Nile virus, St. Louis encephalitis virus, Japanese encephalitis virus, Kunjin virus, Murray Valley virus, Powassan virus, and yellow fever virus). All but 1 of 26 genotypic variants of DENV serotypes in a global DENV panel from different geographic regions were successfully identified. The PCR-LDR assay is a rapid, sensitive, specific, and high-throughput technique for the simultaneous detection of all four serotypes of DENV.

  18. First-trimester maternal serum human thyroid-stimulating hormone in chromosomally normal and Down syndrome pregnancies

    NARCIS (Netherlands)

    Pratt, JJ; de Wolf, BTHM; Mantingh, A

    Maternal serum human thyroid-stimulating hormone (TSH) levels were investigated in chromosomally normal and Down syndrome pregnancies to determine whether TSH can be used as a marker for Down syndrome in the first trimester. Measurements were conducted on stored serum samples collected from 23 Down

  19. Association of testosterone and BDNF serum levels with craving during alcohol withdrawal.

    Science.gov (United States)

    Heberlein, Annemarie; Lenz, Bernd; Opfermann, Birgitt; Gröschl, Michael; Janke, Eva; Stange, Katrin; Groh, Adrian; Kornhuber, Johannes; Frieling, Helge; Bleich, Stefan; Hillemacher, Thomas

    2016-08-01

    Preclinical and clinical studies show associations between testosterone and brain-derived neurotrophic growth factor (BDNF) serum levels. BDNF and testosterone have been independently reported to influence alcohol consumption. Therefore, we aimed to investigate a possible interplay of testosterone and BDNF contributing to alcohol dependence. Regarding possible interplay of testosterone and BDNF and the activity of the hypothalamic pituitary axis (HPA), we included cortisol serum levels in our research. We investigated testosterone and BDNF serum levels in a sample of 99 male alcohol-dependent patients during alcohol withdrawal (day 1, 7, and 14) and compared them to a healthy male control group (n = 17). The testosterone serum levels were significantly (p BDNF serum levels (day 1: p = 0.008). In a subgroup of patients showing high cortisol serum levels (putatively mirroring high HPA activity), we found a significant association of BDNF and testosterone as well as with alcohol craving measured by the Obsessive and Compulsive Drinking Scale (OCDS). Our data suggest a possible association of BDNF and testosterone serum levels, which may be relevant for the symptomatology of alcohol dependence. Further studies are needed to clarify our results. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. A Common Variant in the SETD7 Gene Predicts Serum Lycopene Concentrations.

    Science.gov (United States)

    D'Adamo, Christopher R; D'Urso, Antonietta; Ryan, Kathleen A; Yerges-Armstrong, Laura M; Semba, Richard D; Steinle, Nanette I; Mitchell, Braxton D; Shuldiner, Alan R; McArdle, Patrick F

    2016-02-06

    Dietary intake and higher serum concentrations of lycopene have been associated with lower incidence of prostate cancer and other chronic diseases. Identifying determinants of serum lycopene concentrations may thus have important public health implications. Prior studies have suggested that serum lycopene concentrations are under partial genetic control. The goal of this research was to identify genetic predictors of serum lycopene concentrations using the genome-wide association study (GWAS) approach among a sample of 441 Old Order Amish adults that consumed a controlled diet. Linear regression models were utilized to evaluate associations between genetic variants and serum concentrations of lycopene. Variant rs7680948 on chromosome 4, located in the intron region of the SETD7 gene, was significantly associated with serum lycopene concentrations (p = 3.41 × 10(-9)). Our findings also provided nominal support for the association previously noted between SCARB1 and serum lycopene concentrations, although with a different SNP (rs11057841) in the region. This study identified a novel locus associated with serum lycopene concentrations and our results raise a number of intriguing possibilities regarding the nature of the relationship between SETD7 and lycopene, both of which have been independently associated with prostate cancer. Further investigation into this relationship might help provide greater mechanistic understanding of these associations.

  1. A Common Variant in the SETD7 Gene Predicts Serum Lycopene Concentrations

    Directory of Open Access Journals (Sweden)

    Christopher R. D’Adamo

    2016-02-01

    Full Text Available Dietary intake and higher serum concentrations of lycopene have been associated with lower incidence of prostate cancer and other chronic diseases. Identifying determinants of serum lycopene concentrations may thus have important public health implications. Prior studies have suggested that serum lycopene concentrations are under partial genetic control. The goal of this research was to identify genetic predictors of serum lycopene concentrations using the genome-wide association study (GWAS approach among a sample of 441 Old Order Amish adults that consumed a controlled diet. Linear regression models were utilized to evaluate associations between genetic variants and serum concentrations of lycopene. Variant rs7680948 on chromosome 4, located in the intron region of the SETD7 gene, was significantly associated with serum lycopene concentrations (p = 3.41 × 10−9. Our findings also provided nominal support for the association previously noted between SCARB1 and serum lycopene concentrations, although with a different SNP (rs11057841 in the region. This study identified a novel locus associated with serum lycopene concentrations and our results raise a number of intriguing possibilities regarding the nature of the relationship between SETD7 and lycopene, both of which have been independently associated with prostate cancer. Further investigation into this relationship might help provide greater mechanistic understanding of these associations.

  2. Evaluation of serum lysyl oxidase as a blood test for colorectal cancer.

    Science.gov (United States)

    Ward, S T; Weston, C J; Hepburn, E; Damery, S; Hejmadi, R K; Morton, D G; Middleton, G; Ismail, T; Adams, D H

    2014-06-01

    Lysyl oxidase (LOX) expression is elevated in colorectal cancer (CRC) tissue and associated with disease progression. A blood test may form a more acceptable diagnostic test for CRC although LOX has not previously been measured in the serum. We therefore sought to determine the clinical usefulness of a serum LOX test for CRC in a symptomatic population. Adult patients referred to a hospital colorectal clinic with bowel symptoms completed a questionnaire and provided a blood sample for serum LOX measurement. Associations between presenting symptoms, serum LOX concentrations and outcomes of investigations were tested by univariate and multivariate analyses to determine if serum LOX was clinically useful in the prediction of CRC. LOX expression in CRC and adjacent colon biopsies was evaluated by ELISA and immunohistochemistry. Thirty-one cases of colorectal cancer and 16 high-risk polyps were identified from a total of 962 participants. There was no association between serum LOX concentration and the presence of CRC, high-risk polyps or cancers at any site. LOX expression was significantly increased in CRC tissue compared to adjacent colon. Despite overexpression of LOX in CRC tissue, elevated serum levels could not be demonstrated. Serum LOX measurement is therefore not a clinically useful test for CRC. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. GSTP1, GSTM1 and GSTT1 genetic polymorphisms and total serum GST concentration in stable male COPD

    Directory of Open Access Journals (Sweden)

    Žuntar Irena

    2014-03-01

    Full Text Available The aim of this study was to test the hypothesis that glutathione- S-transferase (GST genotypes were associated with COPD. GSTP1, GSTM1 and GSTT1 genotypes were determined by DNA methods and GST activity spectrophotometrically in older male Caucasian Croats (non- -smokers, ex-smokers, and smokers with stable COPD (n = 30 and sex/age matched controls (n = 60. The distribution of GSTP1 genotypes and alleles in controls vs. COPD showed a statistical difference (p < 0.05. The odds ratio of CC/CT+TT (wild type GSTP1 exon 6 vs. joint heterozygous and mutant homozygous GSTP1 exon 6 was 10.000 and statistically different (p = 0.002. In this study, the GSTP1 mutant genotype of exon 5 (GG, as well as GSTP1 mutant and heterozygous genotypes of exon 6 (TT and CT, were suggested to be genetic contributors to COPD susceptibility. Null GSTM1, null GSTT1 and joint GSTM1/GSTT1 null genotypes were not disease associated. Serum GST was not associated with GST genotypes and COPD or smoking history in our study subjects. Conclusions drawn from the study should be further supported and clarified by studies with larger sample sizes.

  4. Assessment of iron status of Sudanese pregnant women by serum ferritin

    International Nuclear Information System (INIS)

    Eltayeb, E.A.; Khangi, F.A.; Satti, G.M.; Abu Salab, A.

    2004-03-01

    Eighty five normal pregnant women were included in the study at the start of the second trimester. Two blood samples were taken during the second trimester and two blood samples during the third trimester. The height of all subjects was measured. The weights of the subjects were under iron-supplementation throughout the gestation period. Sixty four normal non-parentage women were included in the study to serve as controls. Iron status was assessed for the groups with following parameters, haemoglobin (Hb), packed corpuscular volume (PCV), red blood cells count, peripheral blood film, mean corpuscular volume (MCV), mean cell haemoglobin (MCH), Mean haemoglobin concentration (MCH C), serum iron (Si), total iron binding capacity (T IBC), serum transferrin saturation (Ts) and serum ferritin (Sf). No significant difference was observed in the mean haemoglobin concentrations but the PCV of the non-pregnant women was higher than that of the pregnant women at different stages of gestation (p<0.05). MCV, MCH and MCH C values of the non-pregnant women were lower than those of the of the pregnant at different stages of gestation (p<0.05). Serum iron and transferrin saturation of the non-pregnant women were higher than those of the pregnant women, this difference was statistically significant at weeks (16-18) and (22-24) (p<0.05). Serum ferritin of the non-pregnant women was higher than that of the pregnant women and decreased continuously during the pregnancy, but this decrease was not statistically significant. Iron deficiency anaemia was observed in both pregnant and non-pregnant women. The best parameter that could be used as a marker for iron deficiency is serum ferritin. Iron supplementation s corrected for haemoglobin but not for iron status, but more studies were needed to cover this issue using different parameters.(Author)

  5. Assessment of serum copper, iron and immune complexes in potentially malignant disorders and oral cancer

    Directory of Open Access Journals (Sweden)

    Ritu TIWARI

    Full Text Available Abstract Potentially malignant disorders (PMDs of oral cavity and oral cancer remain a cause of serious concern despite intensive research and development. Diet and immunity have been identified to play a crucial role as modifying factors in these diseases. Our study intended to explore this relationship by estimating and comparing the serum levels of copper, iron and circulating immune complexes (CICs in patients diagnosed with PMDs and oral cancer and normal healthy individuals. In this study, 40 histopathologically diagnosed cases of PMDs and oral cancer were included along with 30 healthy controls and 5 ml of venous blood was drawn using venipuncture. Serum estimation of copper, iron and CIC then followed using the colorimetric and spectrophotometric methods. The data obtained was subjected to statistical analysis using one way ANOVA and Pearson’s Product-Moment Correlation Test. The mean serum copper level was measured as 138.98 ± 10.13µg/100ml in the PMD group and 141.99 ± 21.44 µg/100ml in the oral cancer as compared to 105.5 + 18.81µ/100ml in the controls. The mean serum CIC levels was highest in the oral cancer (9.65 ± 0.16OD470 followed by the PMD group (0.18 + 0.21 OD470 and least in the control group (0.048 ± 0.02OD470. Whereas, the serum levels of iron showed a significant decrease in the PMD group (110.9 ± 10.54 µg/100ml and the oral cancer group (114.29 ± 25.83 µg/100ml as compared with the control group (136.85 ± 14.48 µg/100ml. There was no positive correlation obtained between the three groups with respect to the chosen parameters indicating that the variables were independent of each other. It can be thus be ascertained that trace elements like copper and iron as well as humoral responses (CICs have a close relationship with PMDs and oral cancers.

  6. Label-free LC-MSe in tissue and serum reveals protein networks underlying differences between benign and malignant serous ovarian tumors.

    Directory of Open Access Journals (Sweden)

    Wouter Wegdam

    Full Text Available PURPOSE: To identify proteins and (molecular/biological pathways associated with differences between benign and malignant epithelial ovarian tumors. EXPERIMENTAL PROCEDURES: Serum of six patients with a serous adenocarcinoma of the ovary was collected before treatment, with a control group consisting of six matched patients with a serous cystadenoma. In addition to the serum, homogeneous regions of cells exhibiting uniform histology were isolated from benign and cancerous tissue by laser microdissection. We subsequently employed label-free liquid chromatography tandem mass spectrometry (LC-MSe to identify proteins in these serum and tissues samples. Analyses of differential expression between samples were performed using Bioconductor packages and in-house scripts in the statistical software package R. Hierarchical clustering and pathway enrichment analyses were performed, as well as network enrichment and interactome analysis using MetaCore. RESULTS: In total, we identified 20 and 71 proteins that were significantly differentially expressed between benign and malignant serum and tissue samples, respectively. The differentially expressed protein sets in serum and tissue largely differed with only 2 proteins in common. MetaCore network analysis, however inferred GCR-alpha and Sp1 as common transcriptional regulators. Interactome analysis highlighted 14-3-3 zeta/delta, 14-3-3 beta/alpha, Alpha-actinin 4, HSP60, and PCBP1 as critical proteins in the tumor proteome signature based on their relative overconnectivity. The data have been deposited to the ProteomeXchange with identifier PXD001084. DISCUSSION: Our analysis identified proteins with both novel and previously known associations to ovarian cancer biology. Despite the small overlap between differentially expressed protein sets in serum and tissue, APOA1 and Serotransferrin were significantly lower expressed in both serum and cancer tissue samples, suggesting a tissue-derived effect in serum

  7. Serum alkaline phosphatase screening for vitamin D deficiency states

    International Nuclear Information System (INIS)

    Shaheen, S.; Barrakzai, Q.

    2012-01-01

    Objective: To determine whether serum vitamin D levels are correlated with serum levels of alkaline phosphatase or not. Study Design: Cross-sectional, observational study. Place and Duration of Study: Multi-centre study, conducted at Liaquat National Hospital and Medical College, National Medical Centre and Medicare Hospital, Karachi, from January to October 2009. Methodology: Patients attending the Orthopaedic OPDs with complaints of pain in different body regions and serum vitamin D/sub 3/ levels of greater or equal to 30 ng/ml were included in the study. Patients with vitamin D deficiency were further categorized into mild deficiency or insufficiency (vit. D/sub 3/ = 20-29 ng/ml), moderate deficiency (vit. D/sub 3/ = 5 - 19 ng/ml) and severe deficiency forms (vit. D/sub 3/ < 5 ng/ml). Pearson correlation was applied to test the correlation of serum alkaline phosphatase levels with serum vitamin D/sub 3/ levels. P-value < 0.05 was considered to be significant. Results: Out of 110 samples, 26 had mild (23%), 61 had moderate (55%) and 21 had severe (19.1%) vitamin D deficiencies. All of the patients in the three groups had alkaline phosphatase with in normal limits and the total mean value of the enzyme was 135.97 +- 68.14I U/L. The inter group comparison showed highest values of alkaline phosphatase in the moderate vitamin D deficiency group. The correlation coefficient of alkaline phosphatase and serum vitamin D/sub 3/ levels was r =0.05 (p =0.593). Conclusion: Serum vitamin D/sub 3/ levels may not be correlated with increased serum alkaline phosphatase levels. Therefore, alkaline phosphatase may not be used as a screening test to rule out vitamin D deficiency. (author)

  8. Serum irisin levels in patients with psoriasis.

    Science.gov (United States)

    Baran, Anna; Myśliwiec, Hanna; Kiluk, Paulina; Świderska, Magdalena; Flisiak, Iwona

    2017-06-01

    Irisin has been proposed to regulate metabolic diseases such as obesity, diabetes or metabolic syndrome which are common comorbidities in psoriasis. The aim of this study was to evaluate the serum irisin level in psoriasis and elucidate possible associations with disease activity, inflammatory or metabolic parameters and topical treatment. Thirty-seven individuals with active plaque-type psoriasis and 15 healthy controls were enrolled. Blood samples were collected before and after two weeks of therapy. Serum irisin concentrations were examined by enzyme-linked immunosorbent assay (ELISA). The results were correlated with psoriasis area and severity index (PASI), body mass index (BMI), inflammatory and biochemical markers, lipid profile and effectiveness of topical treatment. Irisin serum levels were insignificantly increased in psoriatic patients in comparison to the controls (p = 0.38). No significant correlations between investigated adipokine and several indicators of metabolic disorders, nor BMI (p = 0.37) or PASI (p = 0.5) were found. Significant positive correlations with C-reactive protein (CRP) (0.009), lipocalin-2 (p = 0.02), age (p = 0.02) and disease duration (p = 0.008) were noted. After topical treatment, serum irisin level did not significantly change (p = 0.31), despite clinical improvement. Irisin might be a marker of inflammation in psoriatic patients, but may not be a reliable indicator of metabolic conditions, severity of psoriasis nor efficacy of antipsoriatic treatment.

  9. Superior serum half life of albumin tagged TNF ligands

    International Nuclear Information System (INIS)

    Mueller, Nicole; Schneider, Britta; Pfizenmaier, Klaus; Wajant, Harald

    2010-01-01

    Due to their immune stimulating and apoptosis inducing properties, ligands of the TNF family attract increasing interest as therapeutic proteins. A general limitation of in vivo applications of recombinant soluble TNF ligands is their notoriously rapid clearance from circulation. To improve the serum half life of the TNF family members TNF, TWEAK and TRAIL, we genetically fused soluble variants of these molecules to human serum albumin (HSA). The serum albumin-TNF ligand fusion proteins were found to be of similar bioactivity as the corresponding HSA-less counterparts. Upon intravenous injection (i.v.), serum half life of HSA-TNF ligand fusion proteins, as determined by ELISA, was around 15 h as compared to approximately 1 h for all of the recombinant control TNF ligands without HSA domain. Moreover, serum samples collected 6 or 24 h after i.v. injection still contained high TNF ligand bioactivity, demonstrating that there is only limited degradation/inactivation of circulating HSA-TNF ligand fusion proteins in vivo. In a xenotransplantation model, significantly less of the HSA-TRAIL fusion protein compared to the respective control TRAIL protein was required to achieve inhibition of tumor growth indicating that the increased half life of HSA-TNF ligand fusion proteins translates into better therapeutic action in vivo. In conclusion, our data suggest that genetic fusion to serum albumin is a powerful and generally applicable mean to improve bioavailability and in vivo activity of TNF ligands.

  10. Serum ferritin and stomach cancer risk among A-bomb survivors

    International Nuclear Information System (INIS)

    Akiba, Suminori; Neriishi, Kazuo; Blot, W.J.; Kabuto, Michinori; Stevens, R.G.; Kato, Hiroo; Land, C.E.

    1990-02-01

    Using stored serum samples collected from 1970-72 and/or from 1977-79, serum ferritin, transferrin, and ceruloplasmin levels were immunologically determined for 233 stomach cancer and 84 lung cancer cases diagnosed from 1973-83 and for 385 matched controls from a fixed population of Hiroshima and Nagasaki atomic bomb survivors. Elevated stomach cancer risk was associated with low serum ferritin levels, with more than a threefold excess among those in the lowest quintile as compared to the highest ferritin quintile. The average serum ferritin concentration was 8% lower in the stomach cancer cases than in the controls. Risk did not vary with the time between blood collection and stomach cancer onset, remaining high among those with low ferritin levels five or more years before cancer diagnosis. Low ferritin combined with achlorhydria, diagnosed about 10 years before the blood collection and up to 25 years before cancer diagnosis, was an exceptionally strong marker of increased stomach cancer risk. No effect of transferrin or ceruloplasmin independent of ferritin was observed on gastric cancer risk. Lung cancer risk was not related to these three serum proteins. (author)

  11. Survey of serum concentrations of dioxins, furans, and coplanar polychlorinated biphenyls in a small non-random sample of U.S. residents

    Energy Technology Data Exchange (ETDEWEB)

    Grassman, J. [Brooklyn Coll. CUNY, Health and Nutrition Sciences, Brooklyn, New York, NY (United States); Patterson, D.G. Jr.; Needham, L.L. [National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Spencer, D.L.; Masten, S.A. [Environmental Toxicology Program, National Inst. of Environmental Health Sciences, Research Triangle Park, NC (United States)

    2004-09-15

    This cross sectional assessment of serum dioxin concentrations was conducted as part of a larger study to examine the relationship between dioxin exposure and gene expression in peripheral blood mononuclear cells. Recent reports indicate that environmental levels of dioxins have declined since the mid-1980's. Except for the recent National Health and Nutrition Examination Survey (NHANES), there has been little systematic surveillance of serum dioxins levels in the US general population. Here, we report the serum concentrations of 22 congeners of dioxins and dioxin-like compounds and their relationship with age, sex, smoking, and meat consumption.

  12. Prevalence of Peste Des Petits Ruminants Virus (PPRV in Mardan, Hangu and Kohat District of Pakistan; Comparative Analysis of PPRV Suspected serum samples using Competitive ELISA (cELISA and Agar Gel Immunodiffusion (AGID

    Directory of Open Access Journals (Sweden)

    Misbah Aslam

    2009-06-01

    Full Text Available Peste des petits Ruminants (PPR is an acute, febrile, highly contagious and economically important viral disease of small ruminants. However PPR is more prevalent in sheep and goat. Competitive ELISA, Virus neutrilization test, and RT-PCR are the available techniques for diagnosis of PPR which give rapid detection where as Agar gel immunodiffusion and Counter immunoelectrophoresis were previously used for PPR detection. In this study two serological techniques were compared for PPR diagnosis. The main aim of this study was to evaluate the comparative sensitivity of both techniques for PPR detection. For this purpose one hundred and sixty PPR suspected serum samples collected from goats and sheep flocks (unvaccinated from three Districts of NWFP including Mardan, Hangu and Kohat were analyzed in National Veterinary Laboratories, Islamabad. Out of these 160 samples, fifty (50 were found positive for PPR antibodies with cELISA (Prevalence = 31.25%. The cELISA positive serum samples however gave negative results when tested with AGID although the control well was always positive. Thus it was concluded that cELISA technique is more sensitive and specific than AGID for PPR antibody detection. [Vet. World 2009; 2(3.000: 89-92

  13. Concurrent determination of total serum calcium and magnesium by thermometric titration with ethylenediaminetetraacetate.

    Science.gov (United States)

    Callicott, R H; Carr, P W

    1976-07-01

    Total serum calcium and magnesium may be determined in one thermometric titration, with disodium ethylenediaminetetraacetate as the titrant. A 1-ml serum sample is diluted with 1 ml of tris(hydroxymethyl)aminomethane buffer (pH 8) and titrated at a constant rate with a motorized syringe buret. Results by the thermometric method compared well with those by atomic absorption spectroscopy.

  14. Reduced serum concentrations of brain-derived neurotrophic factor (BDNF) in transsexual Brazilian men.

    Science.gov (United States)

    Fontanari, Anna Martha Vaitses; Costa, Angelo Brandelli; Aguiar, Bianca; Tusset, Cíntia; Andreazza, Tahiana; Schneider, Maiko; da Rosa, Eduarda Dias; Soll, Bianca Machado Borba; Schwarz, Karine; da Silva, Dhiordan Cardoso; Borba, André Oliveira; Mueller, Andressa; Massuda, Raffael; Lobato, Maria Inês Rodrigues

    2016-09-06

    Serum BDNF levels are significantly decreased in transsexual Brazilian women when compared to cis-sexual men. Since transsexual men are also exposed to chronic social stress and have a high prevalence of associated psychopathologies, it is plausible to inquire if BDNF serum levels are altered in transsexual men as well. Therefore, our objective was to evaluate differences in BDNF serum level of transsexual men when compared to cis-sexual men and women. Our sample comprises 27 transsexual men, 31 cis-sexual women and 30 cis-sexual men recruited between 2011 and 2015. We observed that BDNF serum concentration is decreased in transsexual men comparing to cis-sexual men and women. Cross-sex hormone treatment, chronic social stress or long-term gender dysphoria (GD) could explain the variation found in BDNF serum levels. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Changes in collagen metabolites in serum after cemented hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Joerring, S; Jensen, L T

    1993-01-01

    Markers of types I and III collagen turnover were measured in serial blood samples collected preoperatively and 60 days after surgery in 13 patients undergoing cemented total hip arthroplasty and 11 patients undergoing cemented total knee arthroplasty. The markers were the carboxyterminal extension....... We suggest that the changes in serum PICP and serum PIIINP reflect collagen formation in healing soft connective tissue 60 days after cemented hip or knee arthroplasty....

  16. Aspects of preanalytical variation of lactoferrin and elastase/alpha 1-protease inhibitor complexes

    DEFF Research Database (Denmark)

    Antonsen, S; Qvist, N; Wanscher, M

    1993-01-01

    , if possible. Therefore, we have evaluated the influence of various aspects of sampling and handling conditions on the results obtained when measuring ELA-PI and LAC. Blood samples from both healthy persons as well as patients, who had undergone laparotomy the day before, were investigated. We confirmed...... the previous observations of higher concentrations of ELA-PI and LAC in serum compared to plasma. This was more pronounced in patients than in healthy adults. In EDTA-blood the most important change was seen in samples from patients when stored at room temperature. In this situation increases of LAC...... specimens drawn from healthy persons. EDTA-plasma obtained by venous puncture following minimal stasis contained 10% higher concentrations of LAC compared to samples drawn from intravenous catheters, while no difference was observed in the case of ELA-PI. However, in one individual prolonged venous stasis...

  17. Detection of Volatile Compounds Emitted from Nasal Secretions and Serum: Towards Non-Invasive Identification of Diseased Cattle Biomarkers

    Directory of Open Access Journals (Sweden)

    Devin L. Maurer

    2018-03-01

    Full Text Available Non-invasive diagnostics and finding biomarkers of disease in humans have been a very active research area. Some of the analytical technologies used for finding biomarkers of human disease are finding their use in livestock. Non-invasive sample collection from diseased cattle using breath and headspace of fecal samples have been reported. In this work, we explore the use of volatile organic compounds (VOCs emitted from bovine nasal secretions and serum for finding biomarkers for bovine respiratory disease (BRD. One hundred nasal swabs and 100 serum samples (n = 50 for both ‘sick’ and ‘healthy’ were collected at the time of treatment for suspected BRD. Solid-phase microextraction (SPME was used to collect headspace samples that were analyzed using gas chromatography-mass spectrometry (GC-MS. It was possible to separate sick cattle using non-invasive analyses of nasal swabs and also serum samples by analyzing and comparing volatiles emitted from each group of samples. Four volatile compounds were found to be statistically significantly different between ‘sick’ and ‘normal’ cattle nasal swabs samples. Five volatile compounds were found to be significantly different between ‘sick’ and ‘normal’ cattle serum samples, with phenol being the common marker. Future studies are warranted to improve the extraction efficiency targeting VOCs preliminarily identified in this study. These findings bring us closer to the long-term goal of real-time, animal-side detection and separation of sick cattle.

  18. Reproducibility of positive results for the detection of serum galactomannan by Platelia™ aspergillus EIA.

    Science.gov (United States)

    Pedroza, Kelly C M C; de Matos, Sócrates B; de Moura, Daniel L; Oliveira, Mônica B B; Araújo, Marco A S; Nascimento, Roberto J M; Lima, Fernanda W M

    2013-10-01

    Galactomannan (GM) was recently included in consensus guidelines as an indirect mycological criterion for the diagnosis of invasive aspergillosis. Currently, there is an enzyme immunoassay available to detect GM in biological samples, the Platelia™ Aspergillus EIA. In this study, the reproducibility of positive results obtained using this assay was evaluated using serum samples from neutropenic patients. A trend toward lower values was observed, and 55 %(27/49) of positive results were negative after retesting. A low reproducibility of positive results for the detection of GM in serum was observed.

  19. Segmentectomy for giant pulmonary sclerosing haemangiomas with high serum KL-6 levels

    Science.gov (United States)

    Kuroda, Hiroaki; Mun, Mingyon; Okumura, Sakae; Nakagawa, Ken

    2012-01-01

    We describe a 61-year old female patient with a giant pulmonary sclerosing haemangioma (PSH) and an extremely high preoperative serum KL-6 level. During an annual health screening, the patient showed a posterior mediastinal mass on chest radiography. Chest computed tomography and magnetic resonance imaging revealed a well-circumscribed 60 mm diameter nodule with a marked contrast enhancement in the left lower lobe. The preoperative serum KL-6 level was elevated to 8204 U/ml. We performed a four-port thoracoscopic basal segmentectomy and lymph node sampling for diagnosis and therapy. The postoperative diagnosis showed PSH. The serum KL-6 level decreased dramatically with tumour resection. To the best of our knowledge, this is the first report of a patient with PSH showing a high serum KL-6 level. PMID:22454483

  20. 21 CFR 640.65 - Plasmapheresis.

    Science.gov (United States)

    2010-04-01

    ... sample is drawn to determine whether or not the donor may continue in the program. The review shall be..., the donor shall be removed from the program until these values return to normal. (ii) A donor with a reactive serologic test for syphilis shall not be plasmapheresed again until the donor's serum is tested...

  1. Body mass index and its effect on serum cortisol level

    African Journals Online (AJOL)

    2014-08-21

    Aug 21, 2014 ... In Cushing's syndrome, serum cortisol level is elevated, and obesity is one of ... follows: A baseline blood sample for cortisol, fasting plasma glucose, full ... Continuous variables were expressed as means ± standard deviation.

  2. SPE-HPLC purification of endocrine disrupting compounds from human serum for assessment of xenoestrogenic activity

    DEFF Research Database (Denmark)

    Hjelmborg, P.S.; Ghisari, Mandana; Bonefeld-Jørgensen, Eva

    2006-01-01

    Assessment of xenoestrogenic activity in human serum samples requires the removal of endogenous sex hormones to assure that the activity measured originates from xenobiotic compounds only. Serum samples representing high, medium and lower accumulation of persistent organic pollutants (POPs) were...... measured by ERE-CALUX was validated and considered to be a valuable tool to assess the combined ER effect of lipophilic serum POPs where additive/synergistic and agonistic/antagonistic effects are integrated giving an overall estimate of exposure and bioactivity....... for the study. MVLN cells, stably transfected with an estrogen receptor (ER) luciferase reporter vector (ERE-CALUX), were exposed to the reconstituted SPE-HPLC extracts for determination of the integrated estrogenic activity. The effects of PCBs were analyzed by direct in vitro exposure of PCBs (138, 153...

  3. Osteoprotegerin independently predicts mortality in patients with stable coronary artery disease: the CLARICOR trial

    DEFF Research Database (Denmark)

    Bjerre, Mette; Hilden, Jørgen; Kastrup, Jens

    2014-01-01

    OBJECTIVES: To elucidate the prognostic power of serum osteoprotegerin (OPG) in patients with stable coronary artery disease (CAD). METHODS: Serum OPG levels were measured in the CLARICOR trial cohort of 4063 patients with stable CAD on blood samples drawn at randomization. The follow-up was 2...... predictor for all-cause mortality. Importantly, OPG remained an independent predictor of mortality even after adjustment for both clinical and conventional cardiovascular risk markers (HR 2.5 [95% CI 1.6-3.9, p power as to all...

  4. Distinctive serum protein profiles involving abundant proteins in lung cancer patients based upon antibody microarray analysis

    International Nuclear Information System (INIS)

    Gao, Wei-Min; Haab, Brian B; Hanash, Samir M; Kuick, Rork; Orchekowski, Randal P; Misek, David E; Qiu, Ji; Greenberg, Alissa K; Rom, William N; Brenner, Dean E; Omenn, Gilbert S

    2005-01-01

    Cancer serum protein profiling by mass spectrometry has uncovered mass profiles that are potentially diagnostic for several common types of cancer. However, direct mass spectrometric profiling has a limited dynamic range and difficulties in providing the identification of the distinctive proteins. We hypothesized that distinctive profiles may result from the differential expression of relatively abundant serum proteins associated with the host response. Eighty-four antibodies, targeting a wide range of serum proteins, were spotted onto nitrocellulose-coated microscope slides. The abundances of the corresponding proteins were measured in 80 serum samples, from 24 newly diagnosed subjects with lung cancer, 24 healthy controls, and 32 subjects with chronic obstructive pulmonary disease (COPD). Two-color rolling-circle amplification was used to measure protein abundance. Seven of the 84 antibodies gave a significant difference (p < 0.01) for the lung cancer patients as compared to healthy controls, as well as compared to COPD patients. Proteins that exhibited higher abundances in the lung cancer samples relative to the control samples included C-reactive protein (CRP; a 13.3 fold increase), serum amyloid A (SAA; a 2.0 fold increase), mucin 1 and α-1-antitrypsin (1.4 fold increases). The increased expression levels of CRP and SAA were validated by Western blot analysis. Leave-one-out cross-validation was used to construct Diagonal Linear Discriminant Analysis (DLDA) classifiers. At a cutoff where all 56 of the non-tumor samples were correctly classified, 15/24 lung tumor patient sera were correctly classified. Our results suggest that a distinctive serum protein profile involving abundant proteins may be observed in lung cancer patients relative to healthy subjects or patients with chronic disease and may have utility as part of strategies for detecting lung cancer

  5. Comparison of serum lipid profile in ischaemic and haemorrhagic stroke

    International Nuclear Information System (INIS)

    Mehmood, A.; Sharif, M.A.

    2010-01-01

    To compare serum lipid profile between patients of ischaemic and haemorrhagic strokes. Study Design: Cross sectional, comparative study. Place and Duration of Study: Military Hospital, Rawalpindi, from August 2004 to February 2005. Methodology: Patients with diagnosis of stroke comprising 100 consecutive patients each of ischaemic and haemorrhagic strokes were included in the study while patients on lipid lowering therapy were excluded from study. To determine the subtype of stroke, clinical examination followed by CT scan of brain was done. A serum sample after 8 hours of overnight fasting was taken on the next day of admission for both groups of patients. Total serum cholesterol, triglycerides, LDL cholesterol, VLDL-cholesterol and HDL-cholesterol was determined, using enzymatic colorimetric method. Statistical analysis was done by comparison of lipid profile in two subgroups, using proportion test for any significant difference. Results: The mean age at presentation of patients with stroke was 64.2+-12 years with a male to female ratio of 3.6:1. In 100 ischaemic stroke patients, raised serum total cholesterol was seen in 42, triglyceride in 04, LDL-cholesterol in 05 and VLDL-cholesterol in 07 patients. Serum HDL-cholesterol was below the normal reference in 31 cases. On the other hand, serum total cholesterol and triglycerides was raised in 05 patients each, LDL-cholesterol in 09 and VLDL-cholesterol in 03 patients of haemorrhagic stroke. Serum HDL-cholesterol was below normal in 04 patients of haemorrhagic stroke. On comparison, there were significantly greater number of patients with raised serum cholesterol and low HDL-cholesterol in ischaemic stroke than haemorrhagic stroke (p < 0.05). No statistical significance was found on comparing serum values of ischaemic and haemorrhagic stroke for triglycerides, LDL-cholesterol and VLDL-cholesterol. Conclusion: Ischaemic stroke patients had high serum total cholesterol and lower HDL-cholesterol levels as compared to

  6. Serum concentrations of pituitary and adrenal hormones in female pigs exposed to two photoperiods.

    Science.gov (United States)

    Kraeling, R R; Rampacek, G B; Mabry, J W; Cunningham, F L; Pinkert, C A

    1983-11-01

    Serum concentrations of pituitary and adrenal hormones were determined in lactating sows and ovariectomized (OVX) gilts exposed to 8 h (8L:16D) or 16 h of light (16L:8D). In addition serum prolactin (PRL) concentrations were determined after a thyrotropin releasing hormone (TRH) challenge. At 103 +/- 2 d of gestation or 3 wk after ovariectomy of nulliparous gilts on d 7 to 9 of the estrous cycle (d - 10), blood samples were collected from jugular vein cannulae at 30-min intervals for 8 h beginning at 0800 h. Immediately after the last sample, 13 sows and five OVX gilts were assigned to 8L:16D and 14 sows and five OVX gilts were assigned to 16L:8D/d and placed in two identical chambers in the farrowing house. Blood sampling was repeated on d 7, 14 and 21 of lactation in the sows and on d 7, 14, 21 and 28 in the OVX gilts. In Exp. 1, serum cortisol (C) concentrations were similar for sows exposed to 8L:16D (n = 7) and 16L:8D (n = 6) treatments, whereas in Exp. 2, serum C concentrations for sows exposed to 8L:16D (n = 6) were lower than those exposed to 16L:8D (n = 6) on d 7, 14 and 21. Photoperiod failed to influence serum concentrations of PRL, luteinizing hormone (LH) and growth hormone in the lactating sows or PRL in the OVX gilts. Photoperiod also failed to affect mean basal serum concentrations, peak height and peak frequency for PRL and LH in the lactating sows or for PRL in the OVX gilts.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Evaluation of serum osteopontin level and gene polymorphism as biomarkers

    DEFF Research Database (Denmark)

    Prasmickaite, Lina; Berge, Gisle; Bettum, Ingrid J

    2015-01-01

    samples from 275 high-risk melanoma patients enrolled in the Nordic Adjuvant IFN Melanoma trial were analyzed for circulating OPN concentrations and OPN promoter polymorphisms in position -443. The potential relation between serum OPN levels, the genotypes and survival in non-treated patients and patients...... receiving adjuvant IFN-α was investigated. Although slightly better survival was observed in the treated patients that had high levels of OPN, the difference was not statistically significant. In conclusion, serum OPN (its level or the genotype) cannot distinguish melanoma patients with poor prognosis...

  8. Ultrasensitive radioimmunoassay for direct determination of free triiodothyronine concentration in serum

    International Nuclear Information System (INIS)

    Weeke, J.; Oerskov, H.

    1975-01-01

    Free triiodothyronine (T 3 ) in serum has been measured directly in dialysates of serum, using a wick chromatographic radioimmunoassay. Adequate sensitivity was attained by the use of [ 125 I]T 3 with a very high specific activity (2,000 to 3,000μCi/μg). Sera were dialysed against a Krebs-Ringer bicarbonate buffer modified so as to be similar to plasma water. Dialysis took place under carefully controlled circumstances. The influence on the equilibrium of total to free T 3 of temperature, serum dilution and dialysis time was studied. By the present method, free T 3 in serum from groups of subjects including 20 men, 10 women taking oral contraceptives and 20 women with normal menstrual cycles were identical, averaging 5.2 pg/ml. A chromatographic radioimmunoassay of total T 3 using high specific activity [ 125 I]T 3 and a very small test sample is also described. (auth.)

  9. Variation of serum and urine cotinine in passive and active smokers and applicability in preconceptional smoking cessation counseling

    International Nuclear Information System (INIS)

    Weerd, Sabina de; Thomas, Chris M.G.; Kuster, Josien E.T.G.; Cikot, Rolf J.L.M.; Steegers, Eric A.P.

    2002-01-01

    This study assessed the applicability of serum and urine cotinine as a biochemical marker of self-reported smoking habits for use in a preconception smoking cessation program. The variation of serum and urine cotinine over the course of the day was investigated in a sample of 21 smokers and 8 passive smokers who reported their smoking habits and exposure to smoke daily in a questionnaire for 10 consecutive days. Blood and urine samples were collected on two sampling days, 1 week apart. Both serum and urine cotinine assay could distinguish between passive and active smokers, but not between higher categories of smokers (1019 and ≥20 cigarettes per ay) due to significant intersubject overlap. In serum, no significant differences were found between morning and afternoon cotinine concentrations in either day, in contrast to urine cotinine (with lower excretions observed n the morning). An overall coefficient of variation of 22- was observed for both specimens in smokers. Because serum cotinine is subject to lower variability over the course of the day, it is more practical for use in a clinical setting where appointments are scheduled throughout the day in order o confirm smoking status

  10. Analysis of pig serum proteins based on shotgun liquid ...

    African Journals Online (AJOL)

    Recent advances in proteomics technologies have opened up significant opportunities for future applications. We used shotgun liquid chromatography, coupled with tandem mass spectrometry (LC-MS/MS) to determine the proteome profile of healthy pig serum. Samples of venous blood were collected and subjected to ...

  11. Serum nerve growth factor (NGF) levels in children with attention deficit/hyperactivity disorder (ADHD).

    Science.gov (United States)

    Guney, Esra; Ceylan, Mehmet Fatih; Kara, Mehmet; Tekin, Neslihan; Goker, Zeynep; Senses Dinc, Gulser; Ozturk, Onder; Eker, Sevda; Kizilgun, Murat

    2014-02-07

    Attention deficit/hyperactivity disorder (ADHD) is the most commonly diagnosed neurobehavioral disorder of childhood. The etiopathogeny of ADHD has not been totally defined. Recent reports have suggested a pathophysiological role of neurotrophins in ADHD. In this study, we evaluated serum levels of nerve growth factor (NGF) in patients with ADHD. The sample population consisted of 44 child or adolescent patients diagnosed with ADHD according to DSM-IV criteria; 36 healthy subjects were included in the study as controls. Venous blood samples were collected, and NGF levels were measured. The mean serum NGF levels of the ADHD patients were significantly higher than those of the controls. Age and gender of the patients were not correlated with serum NGF levels. There were no significant differences in NGF levels among the combined and predominantly inattentive subtypes of ADHD. Our study suggests that there are higher levels of serum NGF in drug naive ADHD patients, and that increased levels of NGF might have an important role in the pathophysiology of ADHD. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  12. Soil separator and sampler and method of sampling

    Science.gov (United States)

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  13. Isotope derivative assay of human serum bile acids

    International Nuclear Information System (INIS)

    Pageaux, J.F.; Duperray, B.; Dubois, M.; Pacheco, H.

    1981-01-01

    A new method for the selective determination of the main serum bile acids has been developed. Serum samples with added 14 C-labeled bile acid were submitted to deproteinization, alkaline hydrolysis, methylation, and were then chromatographed on alumina before acetylation with 2 microliters of [ 3 H]acetic anhydride. Excess reagent was eliminated by evaporation; elimination of residual tritiated contaminants and separation of the doubly labeled bile acid derivatives were obtained by thin-layer chromatography, column chromatography on Lipidex 5000, and crystallization. The sensitivity of the method is about 10 pmol of each bile acid. Analyses of seven sera with normal or elevated concentration of bile acids by the proposed method and gas-liquid chromatography showed a close correlation

  14. Serum YKL-40 is increased in patients with hepatic fibrosis

    DEFF Research Database (Denmark)

    Johansen, J S; Christoffersen, P; Møller, S

    2000-01-01

    BACKGROUND/AIMS: YKL-40, a mammalian member of the chitinase family, is a lectin that binds heparin and chitin. The function of YKL-40 is unknown, but it may function in tissue remodelling. The aims of this study were to assess the level of circulating YKL-40 in patients with various kinds...... with the blood sample. RESULTS: The median serum YKL-40 was highest in patients with alcoholic cirrhosis (532 microg/l), in particular in patients with additional alcoholic hepatitis (740 microg/l). Patients with alcoholic cirrhosis, post-hepatitic cirrhosis (425 microg/l) and non-cirrhotic fibrosis (330 microg/l......) had significantly higher serum YKL-40 than normal subjects (102 microg/l), patients with fatty liver (195 microg/l) or patients with viral hepatitis without fibrosis (174 microg/l). Serum YKL-40 was significantly (p

  15. Palladium modified porous silicon as multi-functional MALDI chip for serum peptide detection.

    Science.gov (United States)

    Li, Xiao; Chen, Xiaoming; Tan, Jie; Liang, Xiao; Wu, Jianmin

    2017-02-14

    Interest in using mesoporous materials for peptidomic research has increased recently. The present study reports a new type of matrix assisted laser desorption/ionization (MALDI) plate derived from electrochemically etched porous silicon (PSi) whose surface was modified with palladium nanoparticles (PdNPs). Owing to the well-tailored pore size and the molecular filtration effect of the PSi, peptides in serum samples can be selectively captured and enriched in the pore channel, thereby eliminating the interference from large proteins in subsequent MALDI-MS detection. On the other hand, the PdNPs with localized surface plasmon resonance (LSPR) effect can help to enhance the efficiency of energy absorption in the UV region. Meanwhile, the charge separation effect between the PSi semiconductor and PdNPs also can be applied to promote the accumulation of positive charges on PdNPs, resulting in an improvement in laser desorption/ionization (LDI) efficiency under positive linear detection mode. The interplay among these unique properties of PSi and PdNPs can synergistically increase the overall sensitivity in serum peptide detection. Using this technology, serum sample can be directly detected on the PSi-PdNPs chip without complicated pretreatment process. Therefore, a high fidelity serum peptide fingerprint can be acquired in a high throughput way. With the assistance of statistical analysis, colorectal cancer patients and healthy people can be accurately distinguished based on the serum peptide fingerprints.

  16. Urine and serum fetuin-A levels in patients with urolithiasis.

    Science.gov (United States)

    Arora, Rajat; Abrol, Nitin; Antonisamy, B; Vanitha, S; Chandrasingh, J; Kumar, Santosh; Kekre, Nitin; Devasia, Antony

    2017-01-01

    Fetuin-A is a glycoprotein secreted by liver and has been shown to inhibit extraosseous mineralization. Urolithiasis may be a manifestation in the urinary tract due to fetuin deficiency in urine. The objective of this study was to compare the 24-h urine and serum fetuin-A levels of patients with and without urolithiasis. Serum and 24-h urine fetuin-A levels were measured in 41 patients with bilateral, multiple, or recurrent urinary tract calculi (Group A) and 41 matched controls with no calculi (Group B). Fetuin levels were measured by enzyme linked immunosorbent assay. Serum and urine fetuin-A levels in the two groups were compared. The median (range) 24-h urine fetuin-A value in Group A was 11.9 (1.12-221) mg/day and in Group B was 37.7 (1.28-125) mg/day. This difference was statistically significant (Mann-Whitney test, P = 0.0169). The median (range) serum fetuin-A in Group A was 0.67 (0.05-2.68) g/L and in Group B was 0.99 (0.01-5.5) g/L. The difference between serum values in the two arms was not statistically significant (Mann-Whitney test, P = 0.1817). However, the serum creatinine-adjusted mean log serum fetuin and urine fetuin were significantly different in the two arms ( P = 0.003). The mean ± standard deviation (range) serum creatinine in Group A was 0.98 ± 0.25 (0.56-1.58) mg% and in Group B was 0.83 ± 0.16 (0.58-1.18) mg% (two sample t -test, P = 0.0031). Patients with urolithiasis have lower urine fetuin-A and creatinine-adjusted serum fetuin-A levels.

  17. Levels of serum homocysteine in depressive patients Self-correlation factor analysis and comparison with healthy subjects

    Institute of Scientific and Technical Information of China (English)

    Shanxin Wang; Bin Wang; Aihua Yin; Yang Wang

    2008-01-01

    BACKGROUND: Data indicate that the levels of serum homocysteine in depressive patients are higher than those in normal subjects. OBJECTIVE: To investigate the levels of serum homocysteine in patients with major depressive disorder, to determine whether serum homocysteine levels differ with sex, family history, or drug treatment, and to compare depressive patients with normal subjects. DESIGN: Non-randomized concurrent control trial.SETTING: Mental Heath Center of Shandong Province.PARTICIPANTS: Forty in-patients (23 males and 17 females, 18-63 years old) with major depressive disorder were selected from the Mental Health Center of Shandong Province from January to October 2006. All selected patients met the depressive diagnostic standard of Chinese Classification of Mental Disorder (3rd Edition, CCMD-3), and total scores evaluated by the 17-item Hamilton Rating Scale for Depression (HRSD) were ≥ 20. Meanwhile, 36 healthy subjects (20 males and 16 females, 18-60 years old) were enrolled as controls; their total 17-item HRSD scores were ≤ 7. All selected subjects provided consent, and the study was approved by the local ethics committee. METHODS: Fasting venous blood (3 mL) was drawn in both groups at 8:00 in the morning. The levels of serum homocysteine were determined by a fluorescence polarization immunoassay (FPIA). The 17-item HRSD was also compiled from the patients when entering groups. The higher the scores were, the more severe the depression was. Enumeration data for both groups were compared by Chi-square test, measurement data were compared by t-test, and correlations were detected using Pearson and Spearman correlation analysis.MAIN OUTCOME MEASURES: ① Levels of serum homocysteine; ② incidence of hyperhomocysteinemia (Hhcy); ③ correlation between HRSD17 scores and levels of serum homocysteine in depressive patients.RESULTS: Forty depressive patients and 36 control subjects were included in the final analysis without any loss of participants.

  18. Clinical study on osteopenia, serum sexual hormones and BGP level in the menopausal women

    International Nuclear Information System (INIS)

    Yang Liu; Guo Hui; Duan Liusheng

    2003-01-01

    In order to clarify the mechanism of osteogenesis and osteopenia of the menopausal women, serum [Ca 2+ ], [P 3+ ], AKP, sexual hormones and BGP level were investigated. The blood samples were taken from 177 female individuals who were divided into 5 groups based on different ages of menopause. Serum estradiol, testosterone and BGP were measured by RIA. Serum LH, FSH and PRL were determined by IRMA. Serum [Ca 2+ ], [P 3+ ], AKP were determined by biochemistry analytical methods. Results showed that serum E 2 and T levels in the menopausal women were lower than those in the normal, E 2 decreased significantly. Meanwhile, serum PRL level was only a little lower, but the menopausal female had the higher levels of LH and FSH. Conclusion: the most important cause of osteopenia for the menopausal women is the deficiency of estrogen and degeneration of ovarian function

  19. Membrane potential, serum calcium and serum selenium decrease in preeclampsia subjects in Owerri

    Directory of Open Access Journals (Sweden)

    Johnkennedy Nnodim

    2017-08-01

    Full Text Available Background Pre-eclampsia is a serious hypertensive condition of pregnancy associated with high maternal and fetal morbidity and mortality. Women who have had pre-eclampsia have a greater risk of developing hypertension, stroke and ischemic heart disease in later life. The etiology of pre-eclampsia remains unclear. Placental insufficiency plays a key role in the progression of this disease. The aim of this study was to determine membrane potential, serum calcium and serum selenium levels in preeclampsia subjects in Owerri.   Methods A case control study involving 200 primigravida (100 preeclamptic and 100 apparently healthy between the ages of 20 and 32 years attending General Hospital Owerri. Fasting venous blood was collected for the determination of serum selenium and serum calcium while membrane potential was calculated using the Nernst equation. The serum calcium was estimated using Randox Kit and serum selenium by atomic absorption spectrophotometry. The Independent Student t test was used for statistical analysis.   Results The results revealed that membrane potential and serum selenium as well as serum calcium were significantly decreased in preeclampsia when compared with the controls, at p<0.05.   Conclusion Our study demonstrated that the decrease in membrane potential, serum calcium and serum selenium levels may play a critical role in the pathogenesis of pre-eclampsia. There may be a need for increasing the dietary intake of these essential trace metals during pregnancy to prevent pre-eclampsia in Owerri.

  20. Determination of inorganic nitrate in serum and urine by a kinetic cadmium-reduction method.

    Science.gov (United States)

    Cortas, N K; Wakid, N W

    1990-08-01

    Nitrate in serum and urine was assayed by a modification of the cadmium-reduction method; the nitrite produced was determined by diazotization of sulfanilamide and coupling to naphthylethylene diamine. After samples were deproteinized with Somogyi reagent, the nitrate was reduced by Cu-coated Cd in glycine buffer at pH 9.7 (2.5 to 3 g of Cd granules for a 4-mL reaction mixture). The reduction followed pseudo-first-order reaction kinetics, a convenient time interval for assay being 75 to 90 min. Maximum reduction (85%) occurred at about 2 h. Detection limits in urine or serum were 2 to 250 mumol/L. This method does not require the reaction to go to completion, does not require expensive reagents or equipment, and can assay several samples simultaneously. Repeated assays of two serum pools gave CVs of 9.0% and 4.7% for nitrate concentrations of 31.4 and 80.2 mumol/L, respectively (n = 20 each). The mean concentration of nitrate was 1704.0 +/- 1294 (SD) mumol/L (n = 21) in untimed normal urine, 81.8 +/- 50.1 mumol/L in serum of 38 renal dialysis patients, and 51.2 +/- 26.4 mumol/L in serum of 38 controls.

  1. Driving under the influence of drugs -- evaluation of analytical data of drugs in oral fluid, serum and urine, and correlation with impairment symptoms.

    Science.gov (United States)

    Toennes, Stefan W; Kauert, Gerold F; Steinmeyer, Stefan; Moeller, Manfred R

    2005-09-10

    A study was performed to acquire urine, serum and oral fluid samples in cases of suspected driving under the influence of drugs of abuse. Oral fluid was collected using a novel sampling/testing device (Dräger DrugTest System). The aim of the study was to evaluate oral fluid and urine as a predictor of blood samples positive for drugs and impairment symptoms. Analysis for cannabinoids, amphetamine and its derivatives, opiates and cocaine was performed in urine using the Mahsan Kombi/DOA4-test, in serum using immunoassay and gas chromatography-mass spectrometry (GC-MS) confirmation and in oral fluid by GC-MS. Police and medical officer observations of impairment symptoms were rated and evaluated using a threshold value for the classification of driving inability. Accuracy in correlating drug detection in oral fluid and serum were >90% for all substances and also >90% in urine and serum except for THC (71.0%). Of the cases with oral fluid positive for any drug 97.1% of corresponding serum samples were also positive for at least one drug; of drug-positive urine samples this were only 82.4%. In 119 of 146 cases, impairment symptoms above threshold were observed (81.5%). Of the cases with drugs detected in serum, 19.1% appeared not impaired which were the same with drug-positive oral fluid while more persons with drug-positive urine samples appeared uninfluenced (32.7%). The data demonstrate that oral fluid is superior to urine in correlating with serum analytical data and impairment symptoms of drivers under the influence of drugs of abuse.

  2. Pre- and post-operative values of serum CRP in patients undergoing surgery for brain tumour

    International Nuclear Information System (INIS)

    Syeda, T.; Rizvi, H.A.; Hashim, A.S.

    2014-01-01

    Objective: To determine the concentration of C-reactive protein in pre- and post-operative serum samples of brain tumour patients in order to detect the potential risks of post-operative infections. Methods: Serum C-reactive protein was measured on pre- and post-operative Day 1, Day 2 and Day 7 in 18 patients who underwent surgery for brain tumours. The study was performed at the Neurosurgical Ward, Jinnah Postgraduate Medical Centre, Karachi, from May 2007 to April 2008. Mean pre-operative patients and control values were compared using Mann-Whitney or Wilcoxon tests for comparing between pre- and post-operative values. P-value was considered significant at 5.0mg/L but no statistically significant difference was found when compared with healthy controls, with mean 4.4+-6.6 and 0.9+-0.7, respectively. Significantly raised serum concentrations were observed in all post-operative samples when compared with pre-operative samples. Serum CRP concentrations significantly increased post-operatively on Day 1, with mean value of 102.9+-82.0mg/L (p<0.0005), and further increased on Day 2 with mean value of 166.9+-128.1mg/L (p<0.0005), but declined on Day 7, with mean value of 42.7+-63.6mg/L (p<0.005). Conclusion: Pre-operative serum C-reactive protein concentrations of 28% of the patients were elevated, suggesting an association with brain tumours. Post-operative serum concentrations were significantly higher than those noted before the surgery. Absence of a fall of concentration from peak value on post-operative Day 2 or a secondary rise from post-operative Day 7 could be alarming for inter-current infection. (author)

  3. Differential expression of miRNAs in the serum of patients with high-risk oral lesions

    International Nuclear Information System (INIS)

    MacLellan, Sara Ann; Lawson, James; Baik, Jonathan; Guillaud, Martial; Poh, Catherine Fang-Yeu; Garnis, Cathie

    2012-01-01

    Oral cancer is one of the most commonly diagnosed cancers worldwide. Disease is often diagnosed at later stages, which is associated with a poor 5-year survival rate and a high rate of local recurrence. MicroRNAs (miRNAs), a group of small, noncoding RNAs, can be isolated from blood serum samples and have demonstrated utility as biomarkers in multiple cancer types. The aim of this study was to examine the expression profiles of circulating miRNAs in the serum of patients with high-risk oral lesions (HRLs; oral cancer or carcinoma in situ) and to explore their utility as potential oral cancer biomarkers. Global serum miRNA profiles were generated using quantitative PCR method from 1) patients diagnosed with HRLs and undergoing intent-to-cure surgical treatment (N = 30) and 2) a demographically matched, noncancer control group (N = 26). We next honed our list of serum miRNAs associated with disease by reducing the effects of interpatient variability; we compared serum miRNA profiles from samples taken both before and after tumor resections (N = 10). Based on these analyses, fifteen miRNAs were significantly upregulated and five were significantly downregulated based on presence of disease (minimum fold-change >2 in at least 50% of samples, P < 0.05, permutation). Five of these miRNAs (miR-16, let-7b, miR-338-3p, miR-223, and miR-29a) yielded an area under the ROC curve (AUC) >0.8, suggesting utility as noninvasive biomarkers for detection of oral cancer or high-grade lesions. Combining these serum miRNA profiles with other screening techniques could greatly improve the sensitivity in oral cancer detection

  4. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe...... renal dysfunction (estimated clearance values below 21 ml/min) may be determined with adequate precision by one plasma sample drawn at 24 h after injection of the tracer without sampling at 5 h. This appears to be a very practical simplification....

  5. 77 FR 18207 - Drawn Stainless Steel Sinks From the People's Republic of China: Initiation of Antidumping Duty...

    Science.gov (United States)

    2012-03-27

    ... information or comments that they feel are relevant to the development of an accurate listing of physical... Department of Commerce building. In determining whether Petitioner has standing under section 732(c)(4)(A) of... certain drawn stainless steel sinks obtained from Chinese producers, as identified in affidavits regarding...

  6. Development of optical immunosensors for detection of proteins in serum.

    Science.gov (United States)

    Kyprianou, Dimitris; Chianella, Iva; Guerreiro, Antonio; Piletska, Elena V; Piletsky, Sergey A

    2013-01-15

    The detection of proteins in biological samples such as blood, serum or plasma by biosensors is very challenging due to the complex nature of the matrix, which contains a high level of many interfering compounds. Here we show the application of a novel polymeric immobilisation matrix that helps in the detection of specific protein analytes in biological samples by surface plasmon resonance (SPR) immunosensors. This polymer matrix contains thioacetal functional groups included in the network, and these groups do not require any further activation in order to react with proteins, making it attractive for sensor fabrication. The protein prostate specific antigen (PSA) was selected as a model target analyte. A sandwich format with two primary antibodies recognising different parts (epitopes) of the analyte was used for the detection of PSA in serum. The efficiency of the reduction of non-specific binding achieved with novel polymer was compared with those of other techniques such as coating of sensor surface with polyethylene glycol (PEG), use of charged hydrophilic aspartic acid and surfactants such as Tween20. The detection limit of the polymer based immunosensor was 0.1 ng ml(-1) for free form PSA (f-PSA) in buffer and 5 ng ml(-1) in 20% serum. This is an improvement compared with similar devices reported on literature, indicating the potential of the immunosensor developed here for the analysis of real samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Multiplexed Analysis of Serum Breast and Ovarian Cancer Markers by Means of Suspension Bead-quantum Dot Microarrays

    Science.gov (United States)

    Brazhnik, Kristina; Sokolova, Zinaida; Baryshnikova, Maria; Bilan, Regina; Nabiev, Igor; Sukhanova, Alyona

    Multiplexed analysis of cancer markers is crucial for early tumor diagnosis and screening. We have designed lab-on-a-bead microarray for quantitative detection of three breast cancer markers in human serum. Quantum dots were used as bead-bound fluorescent tags for identifying each marker by means of flow cytometry. Antigen-specific beads reliably detected CA 15-3, CEA, and CA 125 in serum samples, providing clear discrimination between the samples with respect to the antigen levels. The novel microarray is advantageous over the routine single-analyte ones due to the simultaneous detection of various markers. Therefore the developed microarray is a promising tool for serum tumor marker profiling.

  8. Quantitative Evaluation of Serum Proteins Uncovers a Protein Signature Related to Maturity-Onset Diabetes of the Young (MODY).

    Science.gov (United States)

    Tuerxunyiming, Muhadasi; Xian, Feng; Zi, Jin; Yimamu, Yilihamujiang; Abuduwayite, Reshalaiti; Ren, Yan; Li, Qidan; Abudula, Abulizi; Liu, SiQi; Mohemaiti, Patamu

    2018-01-05

    Maturity-onset diabetes of the young (MODY) is an inherited monogenic type of diabetes. Genetic mutations in MODY often cause nonsynonymous changes that directly lead to the functional distortion of proteins and the pathological consequences. Herein, we proposed that the inherited mutations found in a MODY family could cause a disturbance of protein abundance, specifically in serum. The serum samples were collected from a Uyghur MODY family through three generations, and the serum proteins after depletion treatment were examined by quantitative proteomics to characterize the MODY-related serum proteins followed by verification using target quantification of proteomics. A total of 32 serum proteins were preliminarily identified as the MODY-related. Further verification test toward the individual samples demonstrated the 12 candidates with the significantly different abundance in the MODY patients. A comparison of the 12 proteins among the sera of type 1 diabetes, type 2 diabetes, MODY, and healthy subjects was conducted and revealed a protein signature related with MODY composed of the serum proteins such as SERPINA7, APOC4, LPA, C6, and F5.

  9. Limited sampling strategies drawn within 3 hours postdose poorly predict mycophenolic acid area-under-the-curve after enteric-coated mycophenolate sodium.

    NARCIS (Netherlands)

    Winter, B.C. de; Gelder, T. van; Mathôt, R.A.A.; Glander, P.; Tedesco-Silva, H.; Hilbrands, L.B.; Budde, K.; Hest, R.M. van

    2009-01-01

    Previous studies predicted that limited sampling strategies (LSS) for estimation of mycophenolic acid (MPA) area-under-the-curve (AUC(0-12)) after ingestion of enteric-coated mycophenolate sodium (EC-MPS) using a clinically feasible sampling scheme may have poor predictive performance. Failure of

  10. Identification of clinical biomarkers for pre-analytical quality control of blood samples.

    Science.gov (United States)

    Kang, Hyun Ju; Jeon, Soon Young; Park, Jae-Sun; Yun, Ji Young; Kil, Han Na; Hong, Won Kyung; Lee, Mee-Hee; Kim, Jun-Woo; Jeon, Jae-Pil; Han, Bok Ghee

    2013-04-01

    Pre-analytical conditions are key factors in maintaining the high quality of biospecimens. They are necessary for accurate reproducibility of experiments in the field of biomarker discovery as well as achieving optimal specificity of laboratory tests for clinical diagnosis. In research at the National Biobank of Korea, we evaluated the impact of pre-analytical conditions on the stability of biobanked blood samples by measuring biochemical analytes commonly used in clinical laboratory tests. We measured 10 routine laboratory analytes in serum and plasma samples from healthy donors (n = 50) with a chemistry autoanalyzer (Hitachi 7600-110). The analyte measurements were made at different time courses based on delay of blood fractionation, freezing delay of fractionated serum and plasma samples, and at different cycles (0, 1, 3, 6, 9) of freeze-thawing. Statistically significant changes from the reference sample mean were determined using the repeated-measures ANOVA and the significant change limit (SCL). The serum levels of GGT and LDH were changed significantly depending on both the time interval between blood collection and fractionation and the time interval between fractionation and freezing of serum and plasma samples. The glucose level was most sensitive only to the elapsed time between blood collection and centrifugation for blood fractionation. Based on these findings, a simple formula (glucose decrease by 1.387 mg/dL per hour) was derived to estimate the length of time delay after blood collection. In addition, AST, BUN, GGT, and LDH showed sensitive responses to repeated freeze-thaw cycles of serum and plasma samples. These results suggest that GGT and LDH measurements can be used as quality control markers for certain pre-analytical conditions (eg, delayed processing or repeated freeze-thawing) of blood samples which are either directly used in the laboratory tests or stored for future research in the biobank.

  11. Estimations of cholesterol, triglycerides and fractionation of lipoproteins in serum samples of some Nigerian female subjects

    Directory of Open Access Journals (Sweden)

    E.I. Adeyeye

    2011-04-01

    Full Text Available Blood samples (serum were collected to determine some biochemical parameters: total glycerides (TG, total cholesterol (TC, high density lipoprotein-cholesterol (HDL-C, low density lipoprotein-cholesterol (LDL-C and very low density lipoprotein-cholesterol (VLDL-C in 53 female subjects in Warri, Delta State, Nigeria using the Reflotron® (an auto analyser, supported with the use of questionnaire to get information on age and sex. Age range of the subjects was 18–80 years. The TG levels in all the subjects were < 200 mg/dL; only one subject (1.89% had TC < 200 mg/dL; nine subjects (17.0% had HDL-C ≤ 35 mg/dL; for LDL-C only one subject (1.89% had a desirable level of < 130 mg/dL; for VLDL-C 29 subjects (54.7% had values 17.2 mg/dL and above. For therapeutic decision-making, TC/HDL-C and LDL-C/HDL-C, were calculated. In TC/HDL-C, three subjects (5.66% had values < 4.4 and in LDL-C/HDL-C, 41 subjects (77.4% had values < 4.5. Hence, TC, HDL-C, LDL-C, TC/HDL-C and slightly LDL-C/HDL-C and VLDL-C in the subjects could lead to increase coronary heart diseases. Results were matched for the age and sex of subjects.

  12. Mass spectrometry-based serum proteome pattern analysis in molecular diagnostics of early stage breast cancer

    Directory of Open Access Journals (Sweden)

    Stobiecki Maciej

    2009-07-01

    Full Text Available Abstract Background Mass spectrometric analysis of the blood proteome is an emerging method of clinical proteomics. The approach exploiting multi-protein/peptide sets (fingerprints detected by mass spectrometry that reflect overall features of a specimen's proteome, termed proteome pattern analysis, have been already shown in several studies to have applicability in cancer diagnostics. We aimed to identify serum proteome patterns specific for early stage breast cancer patients using MALDI-ToF mass spectrometry. Methods Blood samples were collected before the start of therapy in a group of 92 patients diagnosed at stages I and II of the disease, and in a group of age-matched healthy controls (104 women. Serum specimens were purified and the low-molecular-weight proteome fraction was examined using MALDI-ToF mass spectrometry after removal of albumin and other high-molecular-weight serum proteins. Protein ions registered in a mass range between 2,000 and 10,000 Da were analyzed using a new bioinformatic tool created in our group, which included modeling spectra as a sum of Gaussian bell-shaped curves. Results We have identified features of serum proteome patterns that were significantly different between blood samples of healthy individuals and early stage breast cancer patients. The classifier built of three spectral components that differentiated controls and cancer patients had 83% sensitivity and 85% specificity. Spectral components (i.e., protein ions that were the most frequent in such classifiers had approximate m/z values of 2303, 2866 and 3579 Da (a biomarker built from these three components showed 88% sensitivity and 78% specificity. Of note, we did not find a significant correlation between features of serum proteome patterns and established prognostic or predictive factors like tumor size, nodal involvement, histopathological grade, estrogen and progesterone receptor expression. In addition, we observed a significantly (p = 0

  13. Technical note: Evaluation of digital refractometers to estimate serum immunoglobulin G concentration and passive transfer in Jersey calves.

    Science.gov (United States)

    McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D

    2017-10-01

    Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood

    International Nuclear Information System (INIS)

    McGown, E.L.; Lewis, C.M.; Dong, M.H.; Sauberlich, H.E.

    1978-01-01

    Results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] were compared with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested on whole-blood samples; both yielded values significantly higher than those by microbiological assay. The frequency distributions of erythrocyte folate data differed strikingly between the two kits; the NEN method yielded a much narrower range of normal values than did either the Bio-Rad or the microbiological assay. Radioassay kits appear to be suitable diagnostic agents for serum folate, if the behavior of a particular kit is investigated thoroughly before its routine use. However, the diagnostic value of radioassays of erythrocyte folate needs to be validated

  15. Evaluation of a Serum Lung Cancer Biomarker Panel.

    Science.gov (United States)

    Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria

    2018-01-01

    A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results.

  16. INTRAOCULAR AND SERUM LEVELS OF VASCULAR ENDOTHELIAL GROWTH FACTOR IN ACUTE RETINAL NECROSIS AND OCULAR TOXOPLASMOSIS

    NARCIS (Netherlands)

    Wiertz, Karin; De Visser, Lenneke; Rijkers, Ger; De Groot-Mijnes, Jolanda; Los, Leonie; Rothova, Aniki

    2010-01-01

    Purpose: To determine the intraocular and serum vascular endothelial growth factor (VEGF) levels in patients with acute retinal necrosis (ARN) and compare those with VEGF levels found in patients with ocular toxoplasmosis (OT). Methods: Paired intraocular fluid and serum samples of 17 patients with

  17. Serum galectin-1 in patients with multiple myeloma

    DEFF Research Database (Denmark)

    Andersen, Morten Nørgaard; Ludvigsen, Maja; Abildgaard, Niels

    2017-01-01

    with worse disease state or poor outcome. Gal-1 can be secreted from cells by an unknown mechanism, and levels in blood samples were associated with high tumor burden and worse disease state in cHL and CLL patients. However, serum levels of Gal-1 have never been investigated in patients with multiple myeloma...

  18. Serum Fatty Acids Are Correlated with Inflammatory Cytokines in Ulcerative Colitis.

    Directory of Open Access Journals (Sweden)

    Dawn M Wiese

    Full Text Available Ulcerative colitis (UC is associated with increased dietary intake of fat and n-6 polyunsaturated fatty acids (PUFA. Modification of fat metabolism may alter inflammation and disease severity. Our aim was to assess differences in dietary and serum fatty acid levels between control and UC subjects and associations with disease activity and inflammatory cytokines.Dietary histories, serum, and colonic tissue samples were prospectively collected from 137 UC subjects and 38 controls. Both histologic injury and the Mayo Disease Activity Index were assessed. Serum and tissue cytokines were measured by Luminex assay. Serum fatty acids were obtained by gas chromatography.UC subjects had increased total fat and oleic acid (OA intake, but decreased arachidonic acid (AA intake vs controls. In serum, there was less percent saturated fatty acid (SFA and AA, with higher monounsaturated fatty acids (MUFA, linoleic acid, OA, eicosapentaenoic acid (EPA, and docosapentaenoic acid (DPA in UC. Tissue cytokine levels were directly correlated with SFA and inversely correlated with PUFA, EPA, and DPA in UC subjects, but not controls. 5-aminosalicylic acid therapy blunted these associations.In summary, we found differences in serum fatty acids in UC subjects that correlated with pro-inflammatory tissue cytokines. We propose that fatty acids may affect cytokine production and thus be immunomodulatory in UC.

  19. Serum Fatty Acids Are Correlated with Inflammatory Cytokines in Ulcerative Colitis.

    Science.gov (United States)

    Wiese, Dawn M; Horst, Sara N; Brown, Caroline T; Allaman, Margaret M; Hodges, Mallary E; Slaughter, James C; Druce, Jennifer P; Beaulieu, Dawn B; Schwartz, David A; Wilson, Keith T; Coburn, Lori A

    2016-01-01

    Ulcerative colitis (UC) is associated with increased dietary intake of fat and n-6 polyunsaturated fatty acids (PUFA). Modification of fat metabolism may alter inflammation and disease severity. Our aim was to assess differences in dietary and serum fatty acid levels between control and UC subjects and associations with disease activity and inflammatory cytokines. Dietary histories, serum, and colonic tissue samples were prospectively collected from 137 UC subjects and 38 controls. Both histologic injury and the Mayo Disease Activity Index were assessed. Serum and tissue cytokines were measured by Luminex assay. Serum fatty acids were obtained by gas chromatography. UC subjects had increased total fat and oleic acid (OA) intake, but decreased arachidonic acid (AA) intake vs controls. In serum, there was less percent saturated fatty acid (SFA) and AA, with higher monounsaturated fatty acids (MUFA), linoleic acid, OA, eicosapentaenoic acid (EPA), and docosapentaenoic acid (DPA) in UC. Tissue cytokine levels were directly correlated with SFA and inversely correlated with PUFA, EPA, and DPA in UC subjects, but not controls. 5-aminosalicylic acid therapy blunted these associations. In summary, we found differences in serum fatty acids in UC subjects that correlated with pro-inflammatory tissue cytokines. We propose that fatty acids may affect cytokine production and thus be immunomodulatory in UC.

  20. Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies

    Directory of Open Access Journals (Sweden)

    Elza FT Belo

    Full Text Available Dot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic. The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required.