WorldWideScience

Sample records for serum optical density

  1. Preliminary analysis of the relationship between serum lutein and zeaxanthin levels and macular pigment optical density

    Directory of Open Access Journals (Sweden)

    Fujimura S

    2016-10-01

    Full Text Available Shigeto Fujimura,1,2 Kohei Ueda,1 Yoko Nomura,1 Yasuo Yanagi3,4 1Department of Ophthalmology, University of Tokyo School of Medicine, Tokyo, 2Department of Ophthalmology, Kanazawa University School of Medicine, Ishikawa, Japan; 3Singapore Eye Research Institute, 4Medical Retina Department, Singapore National Eye Centre, Singapore Purpose: To assess the relationship between combined serum lutein and zeaxanthin (L+Z concentration and macular pigment optical density (MPOD, and to investigate the effect of L+Z+docosahexaenoic acid (DHA dietary supplementation on the spatial distribution of MPOD.Methods: Twenty healthy fellow eyes with unilateral wet age-related macular degeneration or chronic central serous chorioretinopathy were included. All participants received a dietary supplement for 6 months that contained 20 mg L, 1 mg Z, and 200 mg DHA. The best-corrected visual acuity and contrast sensitivity (CS were measured at baseline and at 1, 3, and 6 months. Serum L+Z concentrations were measured at baseline and at 3 months. MPOD was calculated at each time point using fundus autofluorescent images.Results: Serum L+Z concentration was correlated with MPOD at 1°–2° eccentricity at baseline (r=0.63, P=0.003 and 3 months (r=0.53, P=0.015. Serum L+Z concentration increased by a factor of 2.3±1.0 (P<0.0001. At 6 months, MPOD was significantly higher compared to the baseline level at 0°–0.25° (P=0.034 and 0.25°–0.5° (P=0.032 eccentricity. CS improved after 3 or 6 months of L+Z+DHA supplementation (P<0.05.Conclusion: Juxtafoveal MPOD was associated with serum L+Z concentration. Foveal MPOD was increased by L+Z+DHA dietary supplementation. Keywords: fundus autofluorescence, supplement, spatial distribution

  2. Macular pigment optical density is related to serum lutein in retinitis pigmentosa

    Science.gov (United States)

    Purpose: To determine whether macular pigment optical density (MPOD) is related to the degree of cystoid macular edema (CME) in patients with retinitis pigmentosa. Methods: We measured MPOD with heterochromatic flicker photometry and central foveal retinal thickness with optical coherence tomography...

  3. Serum carotenoids and macular pigment optical density in patients with intestinal resections and healthy subjects: an exploratory study

    DEFF Research Database (Denmark)

    Eriksen, Jane Nygaard; Prahm, August P; Falk, Mads Krüger

    2018-01-01

    Reduced absorption capacity in patients with intestinal resections (IR) could result in malabsorption of fat-soluble components like carotenoids, which are of clinical interest in relation to visual health. In this case cohort, we investigated the association between IR and serum lutein, zeaxanthin......·0001) in the group with IR. Serum lutein, zeaxanthin, β-carotene and macular pigment optical density were >15 % lower in the patient group compared with healthy controls (P carotenoids. Results suggest...... that for a test of macular carotenoid supplementation, subjects with a potentially clinically significant carotenoid deficit could be recruited among patients with IR....

  4. The effect of modified eggs and an egg-yolk based beverage on serum lutein and zeaxanthin concentrations and macular pigment optical density: results from a randomized trial.

    Directory of Open Access Journals (Sweden)

    Elton R Kelly

    Full Text Available Increasing evidence suggests a beneficial effect of lutein and zeaxanthin on the progression of age-related macular degeneration. The aim of this study was to investigate the effect of lutein or zeaxanthin enriched eggs or a lutein enriched egg-yolk based buttermilk beverage on serum lutein and zeaxanthin concentrations and macular pigment levels. Naturally enriched eggs were made by increasing the levels of the xanthophylls lutein and zeaxanthin in the feed given to laying hens. One hundred healthy volunteers were recruited and randomized into 5 groups for 90 days. Group one added one normal egg to their daily diet and group two received a lutein enriched egg-yolk based beverage. Group three added one lutein enriched egg and group four one zeaxanthin enriched egg to their diet. Group five was the control group and individuals in this group did not modify their daily diet. Serum lutein and zeaxanthin concentrations and macular pigment densities were obtained at baseline, day 45 and day 90. Macular pigment density was measured by heterochromatic flicker photometry. Serum lutein concentration in the lutein enriched egg and egg yolk-based beverage groups increased significantly (p<0.001, 76% and 77%. A strong increase in the serum zeaxanthin concentration was observed in individuals receiving zeaxanthin enriched eggs (P< 0.001, 430%. No changes were observed in macular pigment density in the various groups tested. The results indicate that daily consumption of lutein or zeaxanthin enriched egg yolks as well as an egg yolk-based beverage show increases in serum lutein and zeaxanthin levels that are comparable with a daily use of 5 mg supplements.ClinicalTrials.gov NCT00527553.

  5. Serum bicarbonate and bone mineral density in US adults.

    Science.gov (United States)

    Chen, Wei; Melamed, Michal L; Abramowitz, Matthew K

    2015-02-01

    Chronic metabolic acidosis leads to bone mineral loss and results in lower bone mineral density (BMD), which is a risk factor for osteoporosis-related fractures. The effect of low-level metabolic acidosis on bone density in the general population is unknown. Cross-sectional study. 9,724 nationally representative adults 20 years or older in NHANES (National Health and Nutrition Examination Survey) 1999-2004. Serum bicarbonate level. Lumbar and total BMD, as well as low lumbar and total bone mass, defined as 1.0 SD below the sex-specific mean value of young adults. BMD was measured by dual-energy x-ray absorptiometry and serum bicarbonate was measured in all participants. Both men and women with lower serum bicarbonate levels were more likely to be current smokers and had higher body mass index and estimated net endogenous acid production. There was a significant linear trend across quartiles of serum bicarbonate with lumbar BMD in the total population, as well as in sex-specific models (P=0.02 for all 3 models, P=0.1 for interaction). For total BMD, a significant association was seen with serum bicarbonate level for women but not men (P=0.02 and P=0.1, respectively; P=0.8 for interaction), and a significant association was seen for postmenopausal women but not premenopausal women (P=0.02 and P=0.2, respectively; P=0.5 for interaction). Compared with women with serum bicarbonate levels <24mEq/L, those with serum bicarbonate levels ≥27mEq/L had 0.018-g/cm(2) higher total BMD (95% CI, 0.004-0.032; P=0.01) and 31% lower odds of having low total bone mass (OR, 0.68; 95% CI, 0.46-0.99; P=0.049). Cross-sectional study using a single measurement of serum bicarbonate. Subgroup differences are not definitive. Lower serum bicarbonate levels are associated with lower BMD in US adults. Further studies should examine whether serum bicarbonate levels should be incorporated into the diagnostic assessment and management of osteoporosis. Copyright © 2015 National Kidney Foundation

  6. High Spectral Density Optical Communication Technologies

    CERN Document Server

    Nakazawa, Masataka; Miyazaki, Tetsuya

    2010-01-01

    The latest hot topics of high-spectral density optical communication systems using digital coherent optical fibre communication technologies are covered by this book. History and meaning of a "renaissance" of the technology, requirements to the Peta-bit/s class "new generation network" are also covered in the first part of this book. The main topics treated are electronic and optical devices, digital signal processing including forward error correction, modulation formats as well as transmission and application systems. The book serves as a reference to researchers and engineers.

  7. The effect of serum magnesium levels and serum endothelin-1 levels on bone mineral density in protein energy malnutrition.

    Science.gov (United States)

    Ozturk, C F; Karakelleoglu, C; Orbak, Z; Yildiz, L

    2012-06-01

    An inadequate and imbalanced intake of protein and energy results in protein-energy malnutrition (PEM). It is known that bone mineral density and serum magnesium levels are low in malnourished children. However, the roles of serum magnesium and endothelin-1 (ET-1) levels in the pathophysiology of bone mineralization are obscure. Thus, the relationships between serum magnesium and ET-1 levels and the changes in bone mineral density were investigated in this study. There was a total of 32 subjects, 25 of them had PEM and seven were controls. While mean serum ET-1 levels of the children with kwashiorkor and marasmus showed no statistically significant difference, mean serum ET-1 levels of both groups were significantly higher than that of the control group. Serum magnesium levels were lower than normal value in 9 (36%) of 25 malnourished children. Malnourished children included in this study were divided into two subgroups according to their serum magnesium levels. While mean serum ET-1 levels in the group with low magnesium levels were significantly higher than that of the group with normal magnesium levels (p malnutrition. Our study suggested that lower magnesium levels and higher ET-1 levels might be important factors in changes of bone mineral density in malnutrition. We recommend that the malnourished patients, especially with hypomagnesaemia, should be treated with magnesium early.

  8. Macular pigment density in relation to serum and adipose tissue concentrations of lutein and serum concentrations of zeaxanthin

    NARCIS (Netherlands)

    Broekmans, W.M.R.; Berendschot, T.T.J.R.; Klöpping-Ketelaars, I.A.A.; Vries, A.J. de; Goldbohm, R.A.; Tijburg, L.B.M.; Kardinaal, A.F.M.; Poppel, G. van

    2002-01-01

    Background: Macular pigment (MP), concentrated in the central area of the retina, contains the carotenoids lutein and zeaxanthin. A low MP density could be a risk factor for age-related macular degeneration. Little information is available regarding MP density in relation to serum lutein and

  9. Effects of Environmental Factors on the Growth, Optical Density and ...

    African Journals Online (AJOL)

    . C. vulgaris was cultivated in sterilized natural seawater enriched with F/2-Si medium. Then grow in bucket, tub and photobioreactor (PBR) in outdoor condition. The daily routine work consisted of culture checkups of optical density, biomass ...

  10. Serum osteoprotegerin levels and mammographic density among high-risk women.

    Science.gov (United States)

    Moran, Olivia; Zaman, Tasnim; Eisen, Andrea; Demsky, Rochelle; Blackmore, Kristina; Knight, Julia A; Elser, Christine; Ginsburg, Ophira; Zbuk, Kevin; Yaffe, Martin; Narod, Steven A; Salmena, Leonardo; Kotsopoulos, Joanne

    2018-06-01

    Mammographic density is a risk factor for breast cancer but the mechanism behind this association is unclear. The receptor activator of nuclear factor κB (RANK)/RANK ligand (RANKL) pathway has been implicated in the development of breast cancer. Given the role of RANK signaling in mammary epithelial cell proliferation, we hypothesized this pathway may also be associated with mammographic density. Osteoprotegerin (OPG), a decoy receptor for RANKL, is known to inhibit RANK signaling. Thus, it is of interest to evaluate whether OPG levels modify breast cancer risk through mammographic density. We quantified serum OPG levels in 57 premenopausal and 43 postmenopausal women using an enzyme-linked immunosorbent assay (ELISA). Cumulus was used to measure percent density, dense area, and non-dense area for each mammographic image. Subjects were classified into high versus low OPG levels based on the median serum OPG level in the entire cohort (115.1 pg/mL). Multivariate models were used to assess the relationship between serum OPG levels and the measures of mammographic density. Serum OPG levels were not associated with mammographic density among premenopausal women (P ≥ 0.42). Among postmenopausal women, those with low serum OPG levels had higher mean percent mammographic density (20.9% vs. 13.7%; P = 0.04) and mean dense area (23.4 cm 2 vs. 15.2 cm 2 ; P = 0.02) compared to those with high serum OPG levels after covariate adjustment. These findings suggest that low OPG levels may be associated with high mammographic density, particularly in postmenopausal women. Targeting RANK signaling may represent a plausible, non-surgical prevention option for high-risk women with high mammographic density, especially those with low circulating OPG levels.

  11. Optical density measurements on the examination of colon cancer tissues

    International Nuclear Information System (INIS)

    Touati, E.; Ajaal, T.; Hamassi, A.

    2015-01-01

    Automated quantitative image analysis can aid in cancer diagnosis and, in general, mange medical treatments managements and improve routine medical diagnosis. Early diagnosis can make big difference between life and death. Microscopic images from two tissue types forty-four normal and fifty-eight cancers, was evaluated based on their ability to identify abnormalities in colon images. Optical density approach is applied to extract parameters that exhibit cancer behavior on colon tissues images. Using statistical toolbox, a significant result of (p<0.0001) for the mean and the variance of the optical density parameter were detected, and only (p<0.001) for skewness optical density. based on linear discrimination method, the obtained result shows 905 accuracy for both sensitivity and specificity, and with an overall accuracy of 90% (author)

  12. Effects of stocking density on growth performance, feather growth, intestinal development, and serum parameters of geese.

    Science.gov (United States)

    Yin, L Y; Wang, Z Y; Yang, H M; Xu, L; Zhang, J; Xing, H

    2017-09-01

    This experiment was conducted to evaluate the effects of stocking density on the growth performance, feather growth, intestinal development, and serum parameters of geese. In total, 336 healthy, 28-day-old, male Yangzhou goslings were randomly allotted to 30 plastic wire-floor pens according to 5 stocking densities (2, 3, 4, 5 and 6 birds/m2). The results showed that with the stocking density increased from 2 birds/m2 to 6 birds/m2, the body weights of geese at 42 d (P density was increased to 6 birds/m2. Serum concentrations of alkaline phosphatase (P = 0.013) and triiodothyronine (P density increased. The serum thyroxine concentration of geese from the 6 birds/m2 group was lower than that of geese from the other groups (P density will adversely influence thyroid function and the developments of the body weight, body size, feathers, and small intestine. Under our experimental conditions, we recommend that the stocking density of geese should be kept to 5 or fewer birds/m2 to avoid the negative effects of high stocking density on geese. © 2017 Poultry Science Association Inc.

  13. Role of Echogenic Amniotic Fluid Particles and Optical Density in ...

    African Journals Online (AJOL)

    This study was aimed to correlate echogenic amniotic fluid particle size (AFPS) in late third trimester to fetal lung maturity and amniotic fluid optical density (AFOD) at labor. AFPS were measured with specified criteria by real time transabdominal USG (3.5MHz) while Amniotic Fluid Index (AFI) was measured during routine ...

  14. Crowd Analysis by Using Optical Flow and Density Based Clustering

    DEFF Research Database (Denmark)

    Santoro, Francesco; Pedro, Sergio; Tan, Zheng-Hua

    2010-01-01

    In this paper, we present a system to detect and track crowds in a video sequence captured by a camera. In a first step, we compute optical flows by means of pyramidal Lucas-Kanade feature tracking. Afterwards, a density based clustering is used to group similar vectors. In the last step...

  15. Interocular agreement in melanin and macular pigment optical density.

    NARCIS (Netherlands)

    Kanis, M.J.; Berendschot, T.T.J.M.; van Norren, D.

    2007-01-01

    Macular pigment (MP) and melanin possibly protect the macular area by absorbing blue light and acting as antioxidants. Because little is known about the interocular correlation of melanin, we determined its optical density (MOD) in both eyes of healthy subjects using fundus reflectometry. The

  16. High-Density Near-Field Optical Disc Recording

    Science.gov (United States)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Ide, Naoki; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2005-05-01

    We developed a high-density near-field optical recording disc system using a solid immersion lens. The near-field optical pick-up consists of a solid immersion lens with a numerical aperture of 1.84. The laser wavelength for recording is 405 nm. In order to realize the near-field optical recording disc, we used a phase-change recording media and a molded polycarbonate substrate. A clear eye pattern of 112 GB capacity with 160 nm track pitch and 50 nm bit length was observed. The equivalent areal density is 80.6 Gbit/in2. The bottom bit error rate of 3 tracks-write was 4.5× 10-5. The readout power margin and the recording power margin were ± 30.4% and ± 11.2%, respectively.

  17. Amorphous silicon rich silicon nitride optical waveguides for high density integrated optics

    DEFF Research Database (Denmark)

    Philipp, Hugh T.; Andersen, Karin Nordström; Svendsen, Winnie Edith

    2004-01-01

    Amorphous silicon rich silicon nitride optical waveguides clad in silica are presented as a high-index contrast platform for high density integrated optics. Performance of different cross-sectional geometries have been measured and are presented with regards to bending loss and insertion loss...

  18. Serum γ-Glutamyl Transferase Is Inversely Associated with Bone Mineral Density Independently of Alcohol Consumption

    Directory of Open Access Journals (Sweden)

    Han Seok Choi

    2016-03-01

    Full Text Available Backgroundγ-Glutamyl transferase (GGT is a well-known marker of chronic alcohol consumption or hepatobiliary diseases. A number of studies have demonstrated that serum levels of GGT are independently associated with cardiovascular and metabolic disorders. The purpose of this study was to test if serum GGT levels are associated with bone mineral density (BMD in Korean adults.MethodsA total of 462 subjects (289 men and 173 women, who visited Severance Hospital for medical checkup, were included in this study. BMD was measured using dual energy X-ray absorptiometry. Cross-sectional association between serum GGT and BMD was evaluated.ResultsAs serum GGT levels increased from the lowest tertile (tertile 1 to the highest tertile (tertile 3, BMD decreased after adjusting for confounders such as age, body mass index, amount of alcohol consumed, smoking, regular exercise, postmenopausal state (in women, hypertension, diabetes mellitus, and hypercholesterolemia. A multiple linear regression analysis showed a negative association between log-transformed serum GGT levels and BMD. In a multiple logistic regression analysis, tertile 3 of serum GGT level was associated with an increased risk for low bone mass compared to tertile 1 (odds ratio, 2.271; 95% confidence interval, 1.340 to 3.850; P=0.002.ConclusionSerum GGT level was inversely associated with BMD in Korean adults. Further study is necessary to fully elucidate the mechanism of the inverse relationship.

  19. Lower Serum Creatinine Is Associated with Low Bone Mineral Density in Subjects without Overt Nephropathy

    Science.gov (United States)

    Huh, Ji Hye; Choi, Soo In; Lim, Jung Soo; Chung, Choon Hee; Shin, Jang Yel; Lee, Mi Young

    2015-01-01

    Background Low skeletal muscle mass is associated with deterioration of bone mineral density. Because serum creatinine can serve as a marker of muscle mass, we evaluated the relationship between serum creatinine and bone mineral density in an older population with normal renal function. Methods Data from a total of 8,648 participants (4,573 men and 4,075 postmenopausal women) aged 45–95 years with an estimated glomerular filtration rate >60 ml/min/1.73 m2 were analyzed from the Fourth Korea National Health and Nutrition Examination Survey (2008–2010). Bone mineral density (BMD) and appendicular muscle mass (ASM) were measured using dual-energy X-ray absorptiometry. Receiver operating characteristic curve analysis revealed that the cut points of serum creatinine for sarcopenia were below 0.88 mg/dl in men and 0.75 mg/dl in women. Subjects were divided into two groups: low creatinine and upper normal creatinine according to the cut point value of serum creatinine for sarcopenia. Results In partial correlation analysis adjusted for age, serum creatinine was positively associated with both BMD and ASM. Subjects with low serum creatinine were at a higher risk for low BMD (T-score ≤ –1.0) at the femur neck, total hip and lumbar spine in men, and at the total hip and lumbar spine in women after adjustment for confounding factors. Each standard deviation increase in serum creatinine was significantly associated with reduction in the likelihood of low BMD at the total hip and lumbar spine in both sexes (men: odds ratio (OR) = 0.84 [95% CI = 0.74−0.96] at the total hip, OR = 0.8 [95% CI = 0.68−0.96] at the lumbar spine; women: OR = 0.83 [95% CI = 0.73–0.95] at the total hip, OR=0.81 [95% CI = 0.67–0.99] at the lumbar spine). Conclusions Serum creatinine reflected muscle mass, and low serum creatinine was independently associated with low bone mineral density in subjects with normal kidney function. PMID:26207750

  20. Interrelationships between maternal carotenoid status and newborn infant macular pigment optical density and carotenoid status.

    Science.gov (United States)

    Henriksen, Bradley S; Chan, Gary; Hoffman, Robert O; Sharifzadeh, Mohsen; Ermakov, Igor V; Gellermann, Werner; Bernstein, Paul S

    2013-08-15

    Deposition of the macular pigment carotenoids lutein and zeaxanthin in the human retina occurs early in life. In this study, we examined the interrelationships of maternal carotenoid status and newborn infant macular pigment levels and systemic carotenoid status. As a secondary measure, we also evaluated the effects of intrauterine growth restriction (IUGR) on carotenoid status in term newborn infants. We measured mother and infant skin carotenoids using resonance Raman spectroscopy (RRS), serum carotenoids by HPLC, and mother breast milk carotenoids by HPLC. We measured infant macular pigment levels using noninvasive blue light reflectometry. We enrolled 30 healthy term infants, their mothers, and 10 IUGR infants and their mothers. A subset of 16 infants was imaged for macular pigment optical density (MPOD). Infant serum zeaxanthin levels correlated with MPOD (r = 0.68, P = 0.007). Mother serum zeaxanthin levels correlated with infant MPOD (r = 0.59, P = 0.032). Infant and mother serum lutein did not correlate with MPOD. Mother-infant correlations were found for total serum carotenoids (r = 0.42, P = 0.020) and skin carotenoids (r = 0.48, P = 0.001). No difference was seen between IUGR infants and controls in total serum or skin carotenoids. Mothers of IUGR infants had lower total serum carotenoids (P = 0.019) and breast milk carotenoids than controls (P = 0.006). Our findings suggest that maternal zeaxanthin status may play a more important role than lutein status in macular pigment deposition in utero. Controlled trials are needed to determine whether maternal zeaxanthin prenatal supplementation can raise infant macular pigment levels and/or improve ocular function.

  1. Optically Addressed Nanostructures for High Density Data Storage

    Science.gov (United States)

    2005-10-14

    beam to sub-wavelength resolutions. X. Refereed Journal Publications I. M. D. Stenner , D. J. Gauthier, and M. A. Neifeld, "The speed of information in a...profiles for high-density optical data storage," Optics Communications, Vol.253, pp.56-69, 2005. 5. M. D. Stenner , D. J. Gauthier, and M. A. Neifeld, "Fast...causal information transmission in a medium with a slow group velocity," Physical Review Letters, Vol.94, February 2005. 6. M. D. Stenner , M. A

  2. Development of theoretical oxygen saturation calibration curve based on optical density ratio and optical simulation approach

    Science.gov (United States)

    Jumadi, Nur Anida; Beng, Gan Kok; Ali, Mohd Alauddin Mohd; Zahedi, Edmond; Morsin, Marlia

    2017-09-01

    The implementation of surface-based Monte Carlo simulation technique for oxygen saturation (SaO2) calibration curve estimation is demonstrated in this paper. Generally, the calibration curve is estimated either from the empirical study using animals as the subject of experiment or is derived from mathematical equations. However, the determination of calibration curve using animal is time consuming and requires expertise to conduct the experiment. Alternatively, an optical simulation technique has been used widely in the biomedical optics field due to its capability to exhibit the real tissue behavior. The mathematical relationship between optical density (OD) and optical density ratios (ODR) associated with SaO2 during systole and diastole is used as the basis of obtaining the theoretical calibration curve. The optical properties correspond to systolic and diastolic behaviors were applied to the tissue model to mimic the optical properties of the tissues. Based on the absorbed ray flux at detectors, the OD and ODR were successfully calculated. The simulation results of optical density ratio occurred at every 20 % interval of SaO2 is presented with maximum error of 2.17 % when comparing it with previous numerical simulation technique (MC model). The findings reveal the potential of the proposed method to be used for extended calibration curve study using other wavelength pair.

  3. Relation among serum and tissue concentrations of lutein and zeaxanthin and macular pigment density.

    Science.gov (United States)

    Johnson, E J; Hammond, B R; Yeum, K J; Qin, J; Wang, X D; Castaneda, C; Snodderly, D M; Russell, R M

    2000-06-01

    Lutein and zeaxanthin are the only carotenoids in the macular region of the retina (referred to as macular pigment [MP]). Foods that are rich in lutein and zeaxanthin can increase MP density. Response to dietary lutein and zeaxanthin in other tissues has not been studied. The objective of this study was to examine tissue responses to dietary lutein and zeaxanthin and relations among tissues in lutein and zeaxanthin concentrations. Seven subjects consumed spinach and corn, which contain lutein and zeaxanthin, with their daily diets for 15 wk. At 0, 4, 8, and 15 wk and 2 mo after the study, serum, buccal mucosa cells, and adipose tissue were analyzed for carotenoids, and MP density was measured. Serum and buccal cell concentrations of lutein increased significantly from baseline during dietary modification. Serum zeaxanthin concentrations were greater than at baseline only at 4 wk, whereas buccal cell and adipose tissue concentrations of zeaxanthin did not change. Adipose tissue lutein concentrations peaked at 8 wk. Changes in adipose tissue lutein concentration were inversely related to the changes in MP density, suggesting an interaction between adipose tissue and retina in lutein metabolism. To investigate the possibility of tissue interactions, we examined cross-sectional relations among serum, tissue, and dietary lutein concentrations, anthropometric measures, and MP density in healthy adults. Significant negative correlations were found between adipose tissue lutein concentrations and MP for women, but a significant positive relation was found for men. Sex differences in lutein metabolism may be an important factor in tissue interactions and in determining MP density.

  4. Density and radioactivity distribution of respirable range human serum albumin aerosol

    International Nuclear Information System (INIS)

    Raghunath, B.; Somasundaram, S.; Soni, P.S.

    1988-01-01

    Dry human serum albumin (HSA) aerosol in the respirable size range was generated using the BARC nebulizer. The aerosol was sampled using Lovelace Aerosol Particle Separator (LAPS) and the density of HSA was determined. Labelling of HSA with 99m TcO 4 - was done, both in HSA solution and with dry denatured HSA particles, to study the distribution of radioactivity in both cases. The results are discussed. (author)

  5. Power Spectral Density Specification and Analysis of Large Optical Surfaces

    Science.gov (United States)

    Sidick, Erkin

    2009-01-01

    The 2-dimensional Power Spectral Density (PSD) can be used to characterize the mid- and the high-spatial frequency components of the surface height errors of an optical surface. We found it necessary to have a complete, easy-to-use approach for specifying and evaluating the PSD characteristics of large optical surfaces, an approach that allows one to specify the surface quality of a large optical surface based on simulated results using a PSD function and to evaluate the measured surface profile data of the same optic in comparison with those predicted by the simulations during the specification-derivation process. This paper provides a complete mathematical description of PSD error, and proposes a new approach in which a 2-dimentional (2D) PSD is converted into a 1-dimentional (1D) one by azimuthally averaging the 2D-PSD. The 1D-PSD calculated this way has the same unit and the same profile as the original PSD function, thus allows one to compare the two with each other directly.

  6. A one-step separation of human serum high density lipoproteins 2 and 3 by rate-zonal density gradient ultracentrifugation in a swinging bucket rotor

    NARCIS (Netherlands)

    Groot, P.H.E.; Scheek, L.M.; Havekes, L.; Noort, W.L. van; Hooft, F.M. van 't

    1982-01-01

    A method was developed for the separation of the high density lipoprotein subclasses HDL2 and HDL3 from human serum. Six serum samples are fractionated in a single-step ultracentrifugal procedure using the Beckman (SW-40) swinging bucket rotor. The method is based on a difference in flotation rate

  7. Nonimaging optical designs for maximum-power-density remote irradiation.

    Science.gov (United States)

    Feuermann, D; Gordon, J M; Ries, H

    1998-04-01

    Designs for flexible, high-power-density, remote irradiation systems are presented. Applications include industrial infrared heating such as in semiconductor processing, alternatives to laser light for certain medical procedures, and general remote high-brightness lighting. The high power densities in herent to the small active radiating regions of conventional metal-halide, halogen, xenon, microwave-sulfur, and related lamps can be restored with nonimaging concentrators with little loss of power. These high fluxlevels can then be transported at high transmissivity with light channels such as optical fibers or lightpipes, and reshaped into luminaires that can deliver prescribed angular and spatial flux distributions onto desired targets. Details for nominally two- and three-dimensional systems are developed, along with estimates ofoptical performance.

  8. Serum anti-Helicobacter pylori immunoglobulin G titer correlates with grade of histological gastritis, mucosal bacterial density, and levels of serum biomarkers.

    Science.gov (United States)

    Tu, Huakang; Sun, Liping; Dong, Xiao; Gong, Yuehua; Xu, Qian; Jing, Jingjing; Yuan, Yuan

    2014-03-01

    OBJECTIVE. Clinical implications of serum anti-Helicobacter pylori immunoglobulin G (IgG) titer were unclear. This study investigated the associations of serum anti-H. pylori IgG titer with grade of histological gastritis, mucosal bacterial density and levels of serum biomarkers, including pepsinogen (PG) I, PGII, PGI/II ratio and gastrin-17. MATERIAL AND METHODS. Study participants were from a screening program in northern China. Serum anti-H. pylori IgG measurements were available for 5922 patients with superficial gastritis. Serum anti-H. pylori IgG titer and serum biomarkers were measured using ELISA, and gastric biopsies were evaluated using standardized criteria. RESULTS. In patients with mild, moderate or severe superficial gastritis, the mean serum anti-H. pylori IgG titers were 17.3, 33.4 and 54.4 EIU (p for trend histological gastritis, mucosal bacterial density and concentrations of serum PGI, PGII and gastrin-17, and negatively with PGI/II ratio.

  9. Development of optical immunosensors for detection of proteins in serum.

    Science.gov (United States)

    Kyprianou, Dimitris; Chianella, Iva; Guerreiro, Antonio; Piletska, Elena V; Piletsky, Sergey A

    2013-01-15

    The detection of proteins in biological samples such as blood, serum or plasma by biosensors is very challenging due to the complex nature of the matrix, which contains a high level of many interfering compounds. Here we show the application of a novel polymeric immobilisation matrix that helps in the detection of specific protein analytes in biological samples by surface plasmon resonance (SPR) immunosensors. This polymer matrix contains thioacetal functional groups included in the network, and these groups do not require any further activation in order to react with proteins, making it attractive for sensor fabrication. The protein prostate specific antigen (PSA) was selected as a model target analyte. A sandwich format with two primary antibodies recognising different parts (epitopes) of the analyte was used for the detection of PSA in serum. The efficiency of the reduction of non-specific binding achieved with novel polymer was compared with those of other techniques such as coating of sensor surface with polyethylene glycol (PEG), use of charged hydrophilic aspartic acid and surfactants such as Tween20. The detection limit of the polymer based immunosensor was 0.1 ng ml(-1) for free form PSA (f-PSA) in buffer and 5 ng ml(-1) in 20% serum. This is an improvement compared with similar devices reported on literature, indicating the potential of the immunosensor developed here for the analysis of real samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Acetaldehyde binding increases the catabolism of rat serum low-density lipoproteins

    International Nuclear Information System (INIS)

    Savolainen, M.J.; Baraona, E.; Lieber, C.S.

    1987-01-01

    Acetaldehyde was found to form adducts with rat serum lipoproteins. The binding of [ 14 C]acetaldehyde to lipoproteins was studied at low concentrations which are known to exist during ethanol oxidation. The amount of lipoprotein adducts was a linear function of acetaldehyde concentration up to 250 μM. Incubation of rat plasma low-density lipoproteins (LDL) with 200 μM acetaldehyde increased the disappearance rate of the 3 H-label from the cholesterol ester moiety of LDL injected into normal rats. The data show that even low concentrations of acetaldehyde are capable of affecting LDL metabolism. These findings may provide an explanation for the low concentrations of serum LDL in alcoholics. The alcohol-induced hyperlipidemia includes either a lack of increase or a decrease in the low-density lipoprotein (LDL) concentration, but the underlying mechanism is not known. It has been shown previously, that the acetylation of lysine residues of LDL apoprotein (apoB) by acetanhydride leads to rapid uptake of LDL particles by macrophages through a non-LDL receptor pathway. Since acetaldehyde, the first toxic metabolite of ethanol, is a chemically reactive compound capable of binding to proteins, they tested whether acetaldehyde forms adducts with serum lipoproteins and subsequently alters the catabolism of LDL. 19 references, 2 figures, 1 table

  11. Association between serum 25-hydroxyvitamin D levels and bone mineral density in normal postmenopausal women

    Directory of Open Access Journals (Sweden)

    Vasundhara Kamineni

    2016-01-01

    Full Text Available Aim: This study was conducted with the objective of assessing serum 25-hydroxyvitamin D (25(OHD in postmenopausal women (PMW, to detect osteopenia or osteoporosis in PMW and to establish a correlation between serum 25(OHD levels and bone mineral density (BMD. Materials and Methods: A total of 100 healthy PMW were selected, and a prospective observational study was conducted to correlate the BMD with serum 25(OHD levels. Their laboratory investigations along with serum 25(OHD levels were done. Their BMD was assessed with dual-energy X-ray absorptiometry at lumbar spine and neck of femur; T-scores were derived. Correlation analysis was done to investigate the relationship between serum 25(OHD levels and BMD. Results: The proportion of osteoporosis at the hip was 31.9% in deficient group, 16.1% in insufficient, and 18.2% in sufficient group and at lumbar spine, it was 27.7%, 16.1%, and 22.7%, respectively. Forty-seven percent of PMW had deficient (<20 ng/ml serum 25(OHD levels and 31% had insufficiency. T-score at hip in deficient group was −2.05 ± 0.25, and in an insufficient group, it was −1.79 ± 0.13; T-score at lumbar spine was −1.92 ± 0.12 and −1.79 ± 0.12, respectively, but both were not statistically significant. Osteoporosis was seen in 24%, osteopenia in 55% at hip level and 23% and 59% respectively at lumbar spine. There was no association between serum 25(OHD levels and BMD neither at hip nor at lumbar spine ( P = 0.51 and P = 0.79 respectively. Conclusion: In this study, among our cohort of patients there was no correlation between serum 25(OHD levels and BMD. However, Vitamin D deficiency coexists with low BMD. Vitamin D insufficiency is a common risk factor for osteoporosis associated with increased bone remodeling and low bone mass.

  12. Serum bone alkaline phosphatase and calcaneus bone density predict fractures: a prospective study.

    Science.gov (United States)

    Ross, P D; Kress, B C; Parson, R E; Wasnich, R D; Armour, K A; Mizrahi, I A

    2000-01-01

    The aim of this study was to assess the ability of serum bone-specific alkaline phosphatase (bone ALP), creatinine-corrected urinary collagen crosslinks (CTx) and calcaneus bone mineral density (BMD) to identify postmenopausal women who have an increased risk of osteoporotic fractures. Calcaneus BMD and biochemical markers of bone turnover (serum bone ALP and urinary CTx) were measured in 512 community-dwelling postmenopausal women (mean age at baseline 69 years) participating in the Hawaii Osteoporosis Study. New spine and nonspine fractures subsequent to the BMD and biochemical bone markers measurements were recorded over an average of 2.7 years. Lateral spinal radiographs were used to identify spine fractures. Nonspine fractures were identified by self-report at the time of each examination. During the 2.7-year follow-up, at least one osteoporotic fracture occurred in 55 (10.7%) of the 512 women. Mean baseline serum bone ALP and urinary CTx were significantly higher among women who experienced an osteoporotic fracture compared with those women who did not fracture. In separate age-adjusted logistic regression models, serum bone ALP, urinary CTx and calcaneus BMD were each significantly associated with new fractures (odds ratios of 1.53, 1.54 and 1.61 per SD, respectively). Multiple variable logistic regression analysis identified BMD and serum bone ALP as significant predictors of fracture (p = 0.002 and 0.017, respectively). The results from this investigation indicate that increased bone turnover is significantly associated with an increased risk of osteoporotic fracture in postmenopausal women. This association is similar in magnitude and independent of that observed for BMD.

  13. Serum oxidized low density lipoprotein levels in preeclamptic and normotensive pregnants.

    Science.gov (United States)

    Kozan, A; Yildirmak, S Turkmen; Mihmanli, V; Ayabakan, H; Cicek, Y G; Kalaslioglu, V; Doean, S; Cebeci, H Cerci

    2015-01-01

    BACKGROUNDS/AIM: The aim of the study was to determine serum lipids and oxidized low density lipoprotein (ox-LDL) levels in preeclamptic pregnants and compare with those of normotensives. Ox-LDL levels were determined by enzyme linked immunosorbent assay (ELISA); total cholesterol, hight density lipoprotein (HDL)-cholesterol and triglyceride levels were measured by enzymatic colorimetric assay in 26 normotensive and 27 preeclamptic pregnants. LDL and very low density lipoprotein (VLDL) cholesterol was calculated by Friedwald formula. Serum levels of Ox-LDL (U/L), total-cholesterol (mg/dL), HDL-cholesterol (mg/dL), LDL-cholesterol (mg/dL), triglyceride (mg/dL), and VLDL-cholesterol (mg/dL) in normotensive and preeclamptic pregnants were found as 130±60 and 133±69; 248±49 and 248±81; 67±14 and 61±16; 147±61 and 135±59; 207±76 and 256±87; 41±15 and 50±17, respectively. Mean values of Ox-LDL and other lipid parameters were higher than the upper limits of their reference ranges in both of groups. However no significant differences were found in Ox-LDL, total, HDL and LDL-cholesterol levels between two groups. However, the levels of triglyceride and VLDL-cholesterol were significantly higher in preeclampsia group. The present results suggest that the levels of serum Ox-LDL and other lipid parameters rise as a result of pregnancy rather than as a result of preeclampsia.

  14. Liver lipase and high-density lipoprotein. Lipoprotein changes after incubation of human serum with rat liver lipase.

    Science.gov (United States)

    Groot, P H; Scheek, L M; Jansen, H

    1983-05-16

    Human sera were incubated with rat liver lipase after inactivation of lecithin:cholesterol acyltransferase, and the changes in serum lipoprotein composition were measured. In the presence of liver lipase serum triacylglycerol and phosphatidylcholine were hydrolyzed. The main changes in the concentrations of these lipids were found in the high-density lipoprotein fraction. Subfractionation of high-density lipoprotein by rate-zonal ultracentrifugation showed a prominent decrease in all constituents of high-density lipoprotein2, a smaller decrease in the 'light' high-density lipoprotein3 and an increase in the 'heavy' high-density lipoprotein3. These data support a concept in which liver lipase is involved in high-density lipoprotein2 phospholipid and triacylglycerol catabolism and suggest that as a result of this action high-density lipoprotein2 is converted into high-density lipoprotein3.

  15. [Development of a software standardizing optical density with operation settings related to several limitations].

    Science.gov (United States)

    Tu, Xiao-Ming; Zhang, Zuo-Heng; Wan, Cheng; Zheng, Yu; Xu, Jin-Mei; Zhang, Yuan-Yuan; Luo, Jian-Ping; Wu, Hai-Wei

    2012-12-01

    To develop a software that can be used to standardize optical density to normalize the procedures and results of standardization in order to effectively solve several problems generated during standardization of in-direct ELISA results. The software was designed based on the I-STOD method with operation settings to solve the problems that one might encounter during the standardization. Matlab GUI was used as a tool for the development. The software was tested with the results of the detection of sera of persons from schistosomiasis japonica endemic areas. I-STOD V1.0 (WINDOWS XP/WIN 7, 0.5 GB) was successfully developed to standardize optical density. A serial of serum samples from schistosomiasis japonica endemic areas were used to examine the operational effects of I-STOD V1.0 software. The results indicated that the software successfully overcame several problems including reliability of standard curve, applicable scope of samples and determination of dilution for samples outside the scope, so that I-STOD was performed more conveniently and the results of standardization were more consistent. I-STOD V1.0 is a professional software based on I-STOD. It can be easily operated and can effectively standardize the testing results of in-direct ELISA.

  16. Serum Paraoxonase 1 Activity Is Associated with Fatty Acid Composition of High Density Lipoprotein

    Directory of Open Access Journals (Sweden)

    Maryam Boshtam

    2013-01-01

    Full Text Available Introduction. Cardioprotective effect of high density lipoprotein (HDL is, in part, dependent on its related enzyme, paraoxonase 1 (PON1. Fatty acid composition of HDL could affect its size and structure. On the other hand, PON1 activity is directly related to the structure of HDL. This study was designed to investigate the association between serum PON1 activity and fatty acid composition of HDL in healthy men. Methods. One hundred and forty healthy men participated in this research. HDL was separated by sequential ultracentrifugation, and its fatty acid composition was analyzed by gas chromatography. PON1 activity was measured spectrophotometrically using paraxon as substrate. Results. Serum PON1 activity was directly correlated with the amount of stearic acid and dihomo-gamma-linolenic acid (DGLA. PON1/HDL-C was directly correlated with the amount of miristic acid, stearic acid, and DGLA and was inversely correlated with total amount of ω6 fatty acids of HDL. Conclusion. The fatty acid composition of HDL could affect the activity of its associated enzyme, PON1. As dietary fats are the major determinants of serum lipids and lipoprotein composition, consuming some special dietary fatty acids may improve the activity of PON1 and thereby have beneficial effects on health.

  17. Serum paraoxonase 1 activity is associated with fatty acid composition of high density lipoprotein.

    Science.gov (United States)

    Boshtam, Maryam; Razavi, Amirnader Emami; Pourfarzam, Morteza; Ani, Mohsen; Naderi, Gholam Ali; Basati, Gholam; Mansourian, Marjan; Dinani, Narges Jafari; Asgary, Seddigheh; Abdi, Soheila

    2013-01-01

    Cardioprotective effect of high density lipoprotein (HDL) is, in part, dependent on its related enzyme, paraoxonase 1 (PON1). Fatty acid composition of HDL could affect its size and structure. On the other hand, PON1 activity is directly related to the structure of HDL. This study was designed to investigate the association between serum PON1 activity and fatty acid composition of HDL in healthy men. One hundred and forty healthy men participated in this research. HDL was separated by sequential ultracentrifugation, and its fatty acid composition was analyzed by gas chromatography. PON1 activity was measured spectrophotometrically using paraxon as substrate. Serum PON1 activity was directly correlated with the amount of stearic acid and dihomo-gamma-linolenic acid (DGLA). PON1/HDL-C was directly correlated with the amount of miristic acid, stearic acid, and DGLA and was inversely correlated with total amount of ω 6 fatty acids of HDL. The fatty acid composition of HDL could affect the activity of its associated enzyme, PON1. As dietary fats are the major determinants of serum lipids and lipoprotein composition, consuming some special dietary fatty acids may improve the activity of PON1 and thereby have beneficial effects on health.

  18. Association between serum cystatin C and bone mineral density in Korean adults

    Directory of Open Access Journals (Sweden)

    Yi DW

    2017-11-01

    Full Text Available Dongwon Yi,1,2 Ah Reum Khang,1,2 Hye Won Lee,1,2 Seok Man Son,1,2 Yang Ho Kang1,2 1Division of Endocrinology and Metabolism, Department of Internal Medicine, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, 2Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea Background: Serum cystatin C has been known as a novel marker of preclinical renal dysfunction, and higher cystatin C levels are associated with increased risks of hip and nonvertebral fractures. However, there are few reports on the association between serum cystatin C and bone mineral density (BMD, especially in the Asian population. We evaluated the association between cystatin C levels and BMD of the spine and hip in Korean adults.Methods: A cross-sectional study was performed in 865 Korean adults (325 men and 540 women who participated in a comprehensive medical examination program and underwent bone densitometry. Renal function was assessed by the estimated glomerular filtration rate (eGFR, which was calculated using an equation based on creatinine (eGFRcre and cystatin C (eGFRcys.Results: The serum cystatin C level was negatively correlated with different types of BMD, including the lowest lumbar, total lumbar, femoral neck, and total femur BMD, in women, but not in men. Higher cystatin C levels were associated with a higher prevalence of osteoporosis in women (odds ratio [OR], 3.68; 95% confidence interval [CI], 1.69–8.03; P=0.001, but not in men (OR, 0.85; 95% CI, 0.30–2.38; P=0.761. However, this association was attenuated in the multivariable model adjusted for age, body mass index, serum 25-hydroxyvitamin D3, and creatinine (OR, 1.01; 95% CI, 0.38–2.71 in women. In addition, the eGFRcys showed a stronger positive correlation with BMD than the eGFRcre.Conclusion: Our findings suggest that serum cystatin C levels might help identify women with osteoporosis

  19. Study on the relationship between serum testosterone level and forearm distal bone density in post-menopausal women

    International Nuclear Information System (INIS)

    Li Wenqi; Zhou Zhengli; Li Xin; Zhou Jiwen

    2002-01-01

    Objective: To study the relationship between the androgen level and bone density in post-menopausal women. Methods: Serum testosterone (T) level and forearm distal bone density (BMD) were measured in 39 past-menopausal women who had never taken any estrogen or calcium preparation. Their serum estradiol (E 2 ) levels were about the same. According to their BMD, the 39 subjects were divided into normal (n = 22) and osteoporotic (n = 17) groups. Results: The mean serum testosterone (T) level in the normal group was significantly higher than that in the osteoporotic group (p 1 = 0.72, r 2 0.75; p 1 and r 2 was 0.14, suggesting similarity of the positive cor-relationship for both groups (p > 0.05). Conclusion: Serum testosterone level seems to bear close relationship with bone density and osteoporosis

  20. Flux density calibration in diffuse optical tomographic systems.

    Science.gov (United States)

    Biswas, Samir Kumar; Rajan, Kanhirodan; Vasu, Ram M

    2013-02-01

    The solution of the forward equation that models the transport of light through a highly scattering tissue material in diffuse optical tomography (DOT) using the finite element method gives flux density (Φ) at the nodal points of the mesh. The experimentally measured flux (Umeasured) on the boundary over a finite surface area in a DOT system has to be corrected to account for the system transfer functions (R) of various building blocks of the measurement system. We present two methods to compensate for the perturbations caused by R and estimate true flux density (Φ) from Umeasuredcal. In the first approach, the measurement data with a homogeneous phantom (Umeasuredhomo) is used to calibrate the measurement system. The second scheme estimates the homogeneous phantom measurement using only the measurement from a heterogeneous phantom, thereby eliminating the necessity of a homogeneous phantom. This is done by statistically averaging the data (Umeasuredhetero) and redistributing it to the corresponding detector positions. The experiments carried out on tissue mimicking phantom with single and multiple inhomogeneities, human hand, and a pork tissue phantom demonstrate the robustness of the approach.

  1. Space Density of Optically Selected Type 2 Quasars

    Science.gov (United States)

    Reyes, Reinabelle; Zakamska, Nadia L.; Strauss, Michael A.; Green, Joshua; Krolik, Julian H.; Shen, Yue; Richards, Gordon T.; Anderson, Scott F.; Schneider, Donald P.

    2008-12-01

    Type 2 quasars are luminous active galactic nuclei whose central regions are obscured by large amounts of gas and dust. In this paper, we present a catalog of type 2 quasars from the Sloan Digital Sky Survey, selected based on their optical emission lines. The catalog contains 887 objects with redshifts z < 0.83; this is 6 times larger than the previous version and is by far the largest sample of type 2 quasars in the literature. We derive the [O III]5007 luminosity function (LF) for 108.3 L sun < L [O III] < 1010 L sun (corresponding to intrinsic luminosities up to M[2500 Å] ~= -28 mag or bolometric luminosities up to 4 × 1047 erg s-1). This LF provides robust lower limits to the actual space density of obscured quasars due to our selection criteria, the details of the spectroscopic target selection, and other effects. We derive the equivalent LF for the complete sample of type 1 (unobscured) quasars and determine the ratio of type 2 to type 1 quasar number densities. Our data constrain this ratio to be at least ~1.5:1 for 108.3 L sun < L [O III] < 109.5 L sun at z < 0.3, and at least ~1.2:1 for L [O III] ~ 1010 L sun at 0.3 < z < 0.83. Type 2 quasars are at least as abundant as type 1 quasars in the relatively nearby universe (z <~ 0.8) for the highest luminosities.

  2. Lateral diffusion of the topological charge density in stochastic optical fields

    CSIR Research Space (South Africa)

    Roux, FS

    2010-01-01

    Full Text Available Stochastic (i.e. random and quasi-random) optical fields may contain distributions of optical vortices that are represented by non-uniform topological charge densities. Numerical simulations are used to investigate the evolution under free...

  3. Optical diagnosis of dengue virus infection in human blood serum using Raman spectroscopy

    International Nuclear Information System (INIS)

    Saleem, M; Bilal, M; Anwar, S; Rehman, A; Ahmed, M

    2013-01-01

    We present the optical diagnosis of dengue virus infection in human blood serum using Raman spectroscopy. Raman spectra were acquired from 18 blood serum samples using a laser at 532 nm as the excitation source. A multivariate regression model based on partial least-squares regression is developed that uses Raman spectra to predict dengue infection with leave-one-sample-out cross validation. The prediction of dengue infection by our model yields correlation coefficient r 2 values of 0.9998 between the predicted and reference clinical results. The model was tested for six unknown human blood sera and found to be 100% accurate in accordance with the clinical results. (letter)

  4. Expression of human apolipoprotein A-I epitopes in high density lipoproteins and in serum

    International Nuclear Information System (INIS)

    Marcel, Y.L.; Jewer, D.; Vezina, C.; Milthorp, P.; Weech, P.K.

    1987-01-01

    The expression and immunoreactivity of apolipoprotein (apo) A-I epitopes in high density lipoproteins (HDL) and serum has been investigated using two series of monoclonal antibodies (Mabs) which have been described elsewhere. Series 1 Mabs, identified as 3D4, 6B8, and 5G6, were obtained by immunization and screening with apoA-I, and series 2 Mabs, identified as 2F1, 4H1, 3G10, 4F7, and 5F6, were obtained by immunization and screening with HDL. These Mabs were characterized with respect to their binding to HDL particles in solution. In series 2 Mabs, 2F1, 3G10, and 4F7, which react with apoA-I CNBr-fragments 1 and 2, could precipitate 100% of 125 I-labeled HDL, while 4H1 and 5F6, which react with CNBr fragments 1 and 3, precipitated 90 and 60% of 125 I-labeled HDL, respectively. Therefore, three distinct epitopes mapped to CNBr fragments 1 and 2 have been identified which are expressed on all HDL particles, indicating that several antigenic do mains exist on apoA-I which have the same conformation on all apoA-I-containing lipoproteins. The Mabs reacting at these sites have significantly higher affinity constants for 125 I-labeled HDL than those that failed to precipitate 100% of HDL. This suggests that the high affinity Mabs react with apoA-I epitopes that are both expressed on all lipoproteins and located in thermo-dynamically stable regions of the molecules. All Mabs from series 1 precipitated 35% or less of 125 I-labeled HDL prepared from freshly collected serum, but the proportion of HDL particles expressing the epitopes for these Mabs doubled or more upon serum storage at 4 degrees C. The time course of the alteration of apoA-I antigen in vitro was measured in three normolipemic donors

  5. Increased serum oxidized low-density lipoprotein levels in pregnancies complicated by gestational diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Azam Ghaneei

    2015-07-01

    Full Text Available Background: Elevated serum levels of oxidized Low-density Lipoprotein (oxLDL have been found in type 2 and in poorly controlled diabetic patients. Gestational diabetes mellitus (GDM has common features with type 2 diabetes. Objective: The aim of our study was to evaluate the serum levels of oxLDL in women with GDM compared to normal pregnant women. Materials and Methods: In this cross-sectional study, ninety-two subjects were randomly allocated to either GDM (n=46 or control (n=46 groups matched for age, body mass index and parity from March 2013 to March 2014. GDM was diagnosed according to the American Diabetes Association criteria at 24-26 weeks of gestation. OxLDL was measured using enzyme-linked immunosorbent assay. T-test and Pearson correlation coefficients were applied for analyzing the data by using SPSS version 17. Results: Compared to the controls, significantly higher oxLDL levels were found in the GDM group (17.16 ± 3.71 U/L vs. 8.77 ± 1.84 U/L, respectively, p < 0.001. No significant correlations were found between oxLDL and age and BMI of the patients in the groups. Conclusion: Our study found significant increase of oxLDL in GDM emphasizing the role of short-term hyperglycemia in the formation of oxLDL during GDM. The importance of aptly diagnosis of GDM in maternal health may also be concluded.

  6. Relationships between serum Omentin-1 levels and bone mineral density in older men with osteoporosis

    Institute of Scientific and Technical Information of China (English)

    Li Yang; Xin-Lan Zhao; Bin Liao; Ai-Ping Qin

    2016-01-01

    Objective: To investigate the correlation between serum Omentin-1 levels and the presence of osteoporosis in older men. Methods: Serum Omentin-1, bone turnover biochemical markers, and bone mineral density (BMD) were determined in 45 older men with osteoporosis or 45 older men without osteoporosis (65e70 years old). Results: Omentin-1 levels were increased in older men with osteoporosis, and the differences remained significant after con-trolling for fat mass. Omentin-1 was negatively correlated with BMD. In a multiple linear stepwise regression analysis, Omentin-1, lean mass, but not fat mass, were independent predictors of BMD for the combined group. Significant negative correlations between Omentin-1 and bone-specific alkaline phosphatase (BAP) and bone cross-linked N-telopeptides of typeⅠcollagen (NTX) were found. Omentin-1 was also independently associated with BMD and bone turnover markers in older men with osteoporosis and control groups that were considered separately. Conclusions: Omentin-1 is an independent predictor of BMD in older men with osteoporosis, and it is negatively correlated with bone turnover biochemical markers. It is suggested that Omentin-1 may exert a negative effect on bone mass through the regulation of the osteoblast differentiation in the older men with osteoporosis.

  7. Fiber optic chemical sensors: The evolution of high- density fiber-optic DNA microarrays

    Science.gov (United States)

    Ferguson, Jane A.

    2001-06-01

    Sensors were developed for multianalyte monitoring, fermentation monitoring, lactate analysis, remote oxygen detection for use in bioremediation monitoring and in a fuel spill clean-up project, heavy metal analysis, and high density DNA microarrays. The major focus of this thesis involved creating and improving high-density DNA gene arrays. Fiber optic sensors are created using fluorescent indicators, polymeric supports, and optical fiber substrates. The fluorescent indicator is entrapped in a polymer layer and attached to the tip of the optical fiber. The tip of the fiber bearing the sensing layer (the distal end) is placed in the sample of interest while the other end of the fiber (the proximal end) is connected to an analysis system. Any length of fiber can be used without compromising the integrity or sensitivity of the system. A fiber optic oxygen sensor was designed incorporating an oxygen sensitive fluorescent dye and a gas permeable polymer attached to an optical fiber. The construction simplicity and ruggedness of the sensor enabled its deployment for in situ chemical oxidation and bioremediation studies. Optical fibers were also used as the substrate to detect biomolecules in solution. To monitor bioprocesses, the production of the analyte of interest must be coupled with a species that is optically measurable. For example, oxygen is consumed in many metabolic functions. The fiber optic oxygen sensor is equipped with an additional sensing layer. Upon contact with a specific biochemical in the sample, a reaction occurs in the additional sensing layer that either consumes or produces oxygen. This dual layer system was used to monitor the presence of lactate, an important metabolite for clinical and bioprocess analysis. In many biological and environmental systems, the generation of one species occurs coincidentally with the generation or consumption of another species. A multianalyte sensor was prepared that can monitor the simultaneous activity of pH, CO2

  8. Examination of the constancy of the medium optical density of conventional chest radiographs

    International Nuclear Information System (INIS)

    Stieve, F.E.; Rupp, N.; Niederhofer, F.; Gfirtner, H.

    2002-01-01

    Purpose: To determine whether the medium optical density of conventional chest radiographs is constant. Materials and Methods: 47 PA chest radiographs were digitized to measure the optical density and its dynamic range of normal and pathologically altered lungs. Results: For constant exposure factors and a correctly positioned region of interest, the medium optical density deviates only minimal despite differences in AP chest diameter, entry dose and dynamic range, and is largely independent of the pathologic pulmonary findings. Conclusion: Digitization of the radiograph enables the determination of the physical parameters used to operate the imaging system, such as medium optical density, image contrast, image latitude and density distribution, in accordance to the guidelines of the German Medical Association. If the region of interest encompasses the clinically relevant region of the lung, the measured value of the optical density corresponds with only minor variation to the average value of the entire lung region. (orig.) [de

  9. Optical properties of two-dimensional charge density wave materials

    Science.gov (United States)

    Sayers, Charles; Karbassi, Sara; Friedemann, Sven; da Como, Enrico

    Titanium diselenide (TiSe2) is a member of the layered transition metal dichalcogenide (TMD) materials. It exhibits unusual chiral charge ordering below 190 K after undergoing an initial phase transition to a commensurate (2 x 2 x 2) charge density wave (CDW) at 200 K which is enhanced further in the monolayer. Recently, the first evidence of chirality in a CDW system was discovered in this material by scanning tunneling microscopy and time-resolved reflectivity experiments, where separate left and right handed charge-ordered domains were found to exist within a single sample. We have prepared single crystals of 1T-TiSe2 using iodine vapour transport, and confirmed their quality by x-ray analysis and charge transport measurements. Using a combination of polarised optical spectroscopy techniques in the mid to far infrared (4 to 700 meV photon energy), we have measured an anisotropy relating to the CDW gap. We discuss the results on the basis of chiral domains with different handedness and the nature of the CDW transition.

  10. Serum myostatin in central south Chinese postmenopausal women: Relationship with body composition, lipids and bone mineral density.

    Science.gov (United States)

    Ma, Yulin; Li, Xianping; Zhang, Hongbin; Ou, Yangna; Zhang, Zhimin; Li, Shuang; Wu, Feng; Sheng, Zhifeng; Liao, Eryuan

    2016-08-01

    Previous data suggest that myostatin has direct effects on the proliferation and differentiation of osteoprogenitor cells. The relationships between serum myostatin, body composition lipids and bone mineral density in postmenopausal women remain unclear. The aim of this study is to elucidate the relationships between serum myostatin, body composition, lipids and bone mineral density in central south Chinese postmenopausal women. A cross-sectional study was conducted in 175 healthy postmenopausal women, aged 51-75 years old. Bone mineral density (BMD) and body composition were measured by double energy X-ray absorptiometry (DXA). Serum myostatin, 25-dihydroxyvitamin D(25OH-D), parathyroid hormone (PTH), bone alkaline phosphatase (BAP) and carboxy-terminal telopeptide of type I collagen (CTX) were measured by enzyme-linked immunoabsorbent assay (ELISA). In contrast to the osteoporotic women, the women without osteoporosis had higher BMI, fat mass and lean mass (Pmyostatin after adjusted by age. BMD at each site was positively correlated with age at menopause, fat mass and lean mass, and also negatively correlated with age and serum BAP. Serum myostatin was positively correlated with tryglicerides, not correlated with either body composition or BMD at each site. Our data indicated that serum myostatin concentration did not correlate with muscle and bone mass. Further studies are needed to demonstrate the role of myostatin in regulating the bone metabolism.

  11. Cone photopigment in older subjects: decreased optical density in early age-related macular degeneration

    Science.gov (United States)

    Elsner, Ann E.; Burns, Stephen A.; Weiter, John J.

    2002-01-01

    We measured changes to cone photoreceptors in patients with early age-related macular degeneration. The data of 53 patients were compared with normative data for color matching measurements of long- and middle-wavelength-sensitive cones in the central macula. A four-parameter model quantified cone photopigment optical density and kinetics. Cone photopigment optical density was on average less for the patients than for normal subjects and was uncorrelated with visual acuity. More light was needed to reduce the photopigment density by 50% in the steady state for patients. These results imply that cone photopigment optical density is reduced by factors other than slowed kinetics.

  12. Effects of varying densities on serum reproductive parameters in pen-reared juvenile female rainbow trout Oncorhynchus mykiss farms

    Science.gov (United States)

    Hou, Zhishuai; Wen, Haishen; Li, Jifang; He, Feng; Liu, Qun; Wang, Jinhuan; Guan, Biao; Wang, Qinglong

    2017-01-01

    The primary goal of this study was to assess the effect of varying densities on serum reproductive parameters of immature rainbow trout Oncorhynchus mykiss. Experimental trout were maintained in intensive, pen-reared farms for 300 days in fresh water reservoirs. Initial densities were 4.6, 6.6, and 8.6 kg/m3 (40, 60, 80 ind./m3), indicated as SD1, SD2, SD3, and final densities were 31.1, 40.6, 49.3 kg/m3, respectively. A summary of the ovarian stages were observed by histological examination. Serum E2 (estradiol), T (testosterone) were evaluated by radioimmunoassay and FSH (follicle-stimulating-hormone), LH (luteinizing-hormone), vitellogenin, 17α,20β-P (17α,20βdihydroxy4-pregnen-3-one) were measured by enzyme-linked immunosorbent assay. Our findings demonstrated that ovarian development were retarded (from stage III to stage IV) at highest rearing density (SD3) after 180 days of intensive culture (over 40.6 kg/m3). In addition, we observed an inverse relationship between serum reproductive parameters and rearing density. Furthermore, compared to serum reproductive parameters of SD1, E2, T, FSH, vitellogenin, 17α,20β-P, GSI and LH of two higher density groups decreased firstly and significantly at 60 (over 15.9 kg/m 3 ), 180 (over 31.7 kg/m 3 ), 180 (over 40.6 kg/m3), 240 (over 36 kg/m3), 240 (over 36 kg/m3), 240 (over 45 kg/m3) and 300 (over 49.3 kg/m3) days, respectively. Comparing serum reproductive parameters within the same ovarian development stage of rainbow trout from varying densities revealed that higher population density also led to significantly lower overall serum reproductive parameters. Overall, this study presents the reproductive, endocrinological parameters of juvenile female rainbow trout at high rearing densities and indicates the need for rainbow trout (114.44±5.21 g, 19.69±0.31 cm) that are initially stocked at 6.6 or 8.6 kg/m3 should be classified and subdivided into lower density after 180 days of farming (not over 31.7 kg/m3).

  13. Density profile and cholesterol concentration of serum lipoproteins in experimental animals and human subjects on hypercholesterolaemic diets

    NARCIS (Netherlands)

    Beynen, A.C.; Terpstra, A.H.M.

    1984-01-01

    1. 1. The density profile of Sudan black stained serum lipoproteins was studied in human subjects and various animal species on diets supplemented with cholesterol. 2. 2. In the animals studied (rabbits, calves, mice, chickens, rats and guinea-pigs), the feeding of cholesterol resulted in an

  14. Changes in macular pigment optical density after membrane peeling.

    Science.gov (United States)

    Romano, Mario R; Cennamo, Gilda; Grassi, Piergiacomo; Sparnelli, Federica; Allegrini, Davide; Cennamo, Giovanni

    2018-01-01

    To highlight the differences in macular pigment optical density (MPOD) between eyes with vitreoretinal interface syndrome and healthy control eyes, to assess the changes in MPOD in eyes treated with macular peeling, to investigate the relationships between MPOD changes and measures of retinal sensitivity such as best corrected visual acuity (BCVA) and microperimetry. In this cross-sectional comparative study, 30 eyes affected by idiopathic epiretinal membrane (iERM, 15eyes) or full-thickness macular hole (FTMH, 15eyes) were compared with 60 eyes from 30 healthy age-matched patients. MPOD values (mean MPOD, maximum MPOD, MPOD area, and MPOD volume) were measured in a range of 4°-7° of eccentricity around the fovea, using the one-wavelength reflectometry method (Visucam 200, Carl-Zeiss Meditec). Patients affected by iERM and FTMH were treated with vitrectomy and epiretinal membrane-inner limiting membrane (ERM-ILM) peeling, with follow-up examinations performed preoperatively and 6 months postoperatively. The main outcome measures were the differences in MPOD between eyes with vitreoretinal interface syndrome and healthy eyes, changes in MPOD after ERM-ILM peeling, and relationships between MPOD and functional changes. Mean MPOD differed significantly between control eyes and those with iERM (P = .0001) or FTMH (P = .0006). The max MPOD and MPOD area increased, but not significantly. After peeling, the only significant change in MPOD was in MPOD volume (P = .01). In the ERM group, postoperative mean MPOD correlated significantly with best-corrected visual acuity (r = .739, P = .002). MPOD was reduced in patients with iERM or FTMH compared with healthy eyes. We found a significant correlation between the mean postoperative MPOD and postoperative BCVA, hypothesizing that the postoperative increase in mean MPOD could be due to a change in distribution for unfolding and expansion of the fovea after the peeling. MOPD may be considered as a prognostic factor associated

  15. Correlation between serum anyloid a low density lipoprotein and genotoxicity in smokers

    International Nuclear Information System (INIS)

    Jamil, A.; Rashid, A.; Majeed, A.; Naveed, A.K.

    2018-01-01

    Objective:To investigate the relation between serum amyloid A-low density lipoprotein (SAA-LDL) and genotoxicity in smokers. Study Design:An experimental study. Place and Duration of Study:Army Medical College, Rawalpindi and National Institute of Health (NIH), Islamabad, from June 2014 to February 2015. Methodology:Seventy healthy Sprague Dawley rats were purchased from NIH and exposed to cigarette smoke in smoke chamber for three months. Blood samples were drawn from each rat at the end of the study period. SAA-LDL was determined by enzyme-linked immunosorbent assay (ELISA). Genotoxicity was assessed by cytokinesis block micronucleus (CBMN) assay. Pearson correlation was used to find correlation between SAA-LDL and genotoxicity. Results:Strong positive correlation was found between SAA-LDL and micronuclei frequency in smoke-exposed rats (r=0.799, N=70, p <0.01). Conclusion:Statistically significant strong positive correlation between SAA-LDL and genotoxicity in smoke-exposed rats shows that changes in one is associated with changes in other and vice versa. (author)

  16. High-Density Lipoprotein Cholesterol, Blood Urea Nitrogen, and Serum Creatinine Can Predict Severe Acute Pancreatitis.

    Science.gov (United States)

    Hong, Wandong; Lin, Suhan; Zippi, Maddalena; Geng, Wujun; Stock, Simon; Zimmer, Vincent; Xu, Chunfang; Zhou, Mengtao

    2017-01-01

    Early prediction of disease severity of acute pancreatitis (AP) would be helpful for triaging patients to the appropriate level of care and intervention. The aim of the study was to develop a model able to predict Severe Acute Pancreatitis (SAP). A total of 647 patients with AP were enrolled. The demographic data, hematocrit, High-Density Lipoprotein Cholesterol (HDL-C) determinant at time of admission, Blood Urea Nitrogen (BUN), and serum creatinine (Scr) determinant at time of admission and 24 hrs after hospitalization were collected and analyzed statistically. Multivariate logistic regression indicated that HDL-C at admission and BUN and Scr at 24 hours (hrs) were independently associated with SAP. A logistic regression function (LR model) was developed to predict SAP as follows: -2.25-0.06 HDL-C (mg/dl) at admission + 0.06 BUN (mg/dl) at 24 hours + 0.66 Scr (mg/dl) at 24 hours. The optimism-corrected c-index for LR model was 0.832 after bootstrap validation. The area under the receiver operating characteristic curve for LR model for the prediction of SAP was 0.84. The LR model consists of HDL-C at admission and BUN and Scr at 24 hours, representing an additional tool to stratify patients at risk of SAP.

  17. Long term stability of paraoxonase-1 and high-density lipoprotein in human serum

    Directory of Open Access Journals (Sweden)

    Beekhof Piet K

    2012-05-01

    Full Text Available Abstract Background Paraoxonase-1 (PON1 is an enzyme with numerous functions and receives an increasing interest in clinical and epidemiological studies. Sometimes samples are stored for longer periods at a certain temperature. Therefore the stability of PON1 activity must be checked and retained upon storage for longer periods. Results In this study the stability of PON1 activity has been tested in human serum samples during storage up to 12 months at 3 commonly used temperatures, -20°C, -70°C and −196°C. It was found that the stability of the PON1 activity is constant during 12 months of storage at −70°C and −196°C. Storage at −20°C resulted in a small but statistically significant decrease after 6 months to about 94% of its original value. Nonetheless, the rank order between the samples at T = 0 and 12 months remained the same. The same temperature dependence was found for the associated high-density lipoprotein. Conclusions It can be concluded that −70°C is the right temperature for storage to maintain the PON1 activity for at least one year. Storage at a lower temperature in liquid nitrogen (−196°C is not necessary.

  18. Non-invasive optical detection of HBV based on serum surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Zheng, Zuci; Wang, Qiwen; Weng, Cuncheng; Lin, Xueliang; Lin, Yao; Feng, Shangyuan

    2016-10-01

    An optical method of surface-enhanced Raman spectroscopy (SERS) was developed for non-invasive detection of hepatitis B surface virus (HBV). Hepatitis B virus surface antigen (HBsAg) is an established serological marker that is routinely used for the diagnosis of acute or chronic hepatitis B virus(HBV) infection. Utilizing SERS to analyze blood serum for detecting HBV has not been reported in previous literature. SERS measurements were performed on two groups of serum samples: one group for 50 HBV patients and the other group for 50 healthy volunteers. Blood serum samples are collected from healthy control subjects and patients diagnosed with HBV. Furthermore, principal components analysis (PCA) combined with linear discriminant analysis (LDA) were employed to differentiate HBV patients from healthy volunteer and achieved sensitivity of 80.0% and specificity of 74.0%. This exploratory work demonstrates that SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of HBV.

  19. Density functional study of : Electronic and optical properties

    Indian Academy of Sciences (India)

    K C Bhamu

    3Department of Physics, Swami Keshvanand Insitute of Technology, Management and Gramothan, ... Published online 20 June 2017. Abstract. This paper focusses on the electronic and optical properties of scandium-based silver delafossite.

  20. Alpha slow-moving high-density-lipoprotein subfraction in serum of a patient with radiation enteritis and peritoneal carcinosis

    International Nuclear Information System (INIS)

    Peynet, J.; Legrand, A.; Messing, B.; Thuillier, F.; Rousselet, F.

    1989-01-01

    An alpha slow-moving high-density-lipoprotein (HDL) subfraction was seen in a patient presenting with radiation enteritis and peritoneal carcinosis, who was given long-term cyclic parenteral nutrition. This subfraction, observed in addition to normal HDL, was precipitated with low-density lipoproteins (LDL) and very-low-density lipoproteins (VLDL) by sodium phosphotungstate-magnesium chloride. The patient's serum lipoproteins were analyzed after fractionation by density gradient ultracentrifugation. The alpha slow-moving HDL floated in the ultracentrifugation subfractions with densities ranging from 1.028 to 1.084 kg/L, and their main apolipoproteins included apolipoprotein E in addition to apolipoprotein A-I. These HDL were larger than HDL2. The pathogenesis of this unusual HDL subfraction is hypothesized

  1. Optical properties of Al nanostructures from time dependent density functional theory

    KAUST Repository

    Mokkath, Junais Habeeb; Schwingenschlö gl, Udo

    2016-01-01

    The optical properties of Al nanostructures are investigated by means of time dependent density functional theory, considering chains of varying length and ladders/stripes of varying aspect ratio. The absorption spectra show redshifting

  2. Beam density equalization in a channel with nonlinear optics

    International Nuclear Information System (INIS)

    Batygin, Yu.K.; Kushin, V.V.; Nesterov, N.A.; Plotnikov, S.V.

    1993-01-01

    Simulation of beam density equalization in 2.85 m length transport channel covering two quadrupole lenses and two octupole lenses was carried out to obtain irradiation homogeneous field of track membrane materials. 0.3 MeV/nucleon energy and 1/8 electron-charge-mass ratio ion beam was supplied to the system inlet. Equalization of beam density function equal to about 80% was obtained. 4 refs., 1 fig

  3. Density of states in an optical speckle potential

    International Nuclear Information System (INIS)

    Falco, G. M.; Fedorenko, A. A.; Giacomelli, J.; Modugno, M.

    2010-01-01

    We study the single-particle density of states of a one-dimensional speckle potential, which is correlated and non-Gaussian. We consider both the repulsive and the attractive cases. The system is controlled by a single dimensionless parameter determined by the mass of the particle, the correlation length, and the average intensity of the field. Depending on the value of this parameter, the system exhibits different regimes, characterized by the localization properties of the eigenfunctions. We calculate the corresponding density of states using the statistical properties of the speckle potential. We find good agreement with the results of numerical simulations.

  4. The effect of BCMO1 gene variants on macular pigment optical density in young healthy Caucasians

    Directory of Open Access Journals (Sweden)

    Zachary eKyle-Little

    2014-12-01

    Full Text Available Background: Serum lutein (L and zeaxanthin (Z positively correlate with macular pigment optical density (MPOD, hence the latter is a valuable indirect tool for measuring L and Z content in the macula. L and Z have been attributed antioxidant capacity and protection from certain retinal diseases but their uptake within the eye is thought to depend on genetic, age and environmental factors. In particular gene variants within beta-carotene monooxygenase (BCMO1 are thought to modulate MPOD in the macula.Objectives: To determine the effect of BCMO1 single nucleotide polymorphisms (SNPs rs11645428, rs6420424 and rs6464851 on macular pigment optical density (MPOD in a cohort of young healthy participants of Caucasian origin with normal ocular health.Design: In this cohort study, MPOD was assessed in 46 healthy participants (22 male and 24 female with a mean age of 24 ± 4.0 years (range 19-33. The three SNPs, rs11645428, rs6420424, rs6564851 that have established associations with MPOD were determined using MassEXTEND (hME Sequenom assay. One-way analysis of variance (ANOVA was performed on groups segregated into homozygous and heterozygous BCMO1 genotypes. Correlations between body mass index (BMI, iris colour, gender, central retinal thickness (CRT, diet and MPOD were investigated.Results: MPOD did not significantly vary with BCMO1 rs11645428 (F2,41 = 0.700, p = 0.503, rs6420424 (F2,41 = 0.210, p = 0.801 nor rs6464851 homozygous or heterozygous genotypes (F2,41 = 0,13, p = 0.88, in this young healthy cohort. The combination of these three SNPs into triple genotypes based on plasma conversion efficiency did not affect MPOD (F2,41 = 0.07, p = 0.9. There was a significant negative correlation with MPOD and central retinal thickness (r = - 0.39, p = 0.01 but no significant correlation between BMI, iris colour, gender and MPOD. Conclusion: Our results indicate that macular pigment deposition within the central retina is not dependent on BCMO1 gene variant

  5. High-density near-field optical disc recording using phase change media and polycarbonate substrate

    Science.gov (United States)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2004-09-01

    We developed a high density near field optical recording disc system with a solid immersion lens and two laser sources. In order to realize the near field optical recording, we used a phase change recording media and a molded polycarbonate substrate. The near field optical pick-up consists of a solid immersion lens with numerical aperture of 1.84. The clear eye pattern of 90.2 GB capacity (160nm track pitch and 62 nm per bit) was observed. The jitter using a limit equalizer was 10.0 % without cross-talk. The bit error rate using an adaptive PRML with 8 taps was 3.7e-6 without cross-talk. We confirmed that the near field optical disc system is a promising technology for a next generation high density optical disc system.

  6. SERODS: a new medium for high-density optical data storage

    Science.gov (United States)

    Vo-Dinh, Tuan; Stokes, David L.

    1998-10-01

    A new optical dada storage technology based on the surface- enhanced Raman scattering (SERS) effect has been developed for high-density optical memory and three-dimensional data storage. With the surface-enhanced Raman optical data storage (SERODS) technology, the molecular interactions between the optical layer molecules and the nanostructured metal substrate are modified by the writing laser, changing their SERS properties to encode information as bits. Since the SERS properties are extremely sensitive to molecular nano- environments, very small 'spectrochemical holes' approaching the diffraction limit can be produced for the writing process. The SERODS device uses a reading laser to induce the SERS emission of molecules on the disk and a photometric detector tuned to the frequency of the RAMAN spectrum to retrieve the stored information. The results illustrate that SERODS is capable of three-dimensional data storage and has the potential to achieve higher storage density than currently available optical data storage systems.

  7. Space density of optically-selected type 2 quasars

    OpenAIRE

    Reyes, Reinabelle; Zakamska, Nadia L.; Strauss, Michael A.; Green, Joshua; Krolik, Julian H.; Shen, Yue; Richards, Gordon; Anderson, Scott; Schneider, Donald

    2008-01-01

    Type 2 quasars are luminous active galactic nuclei (AGN) whose central regions are obscured by large amounts of gas and dust. In this paper, we present a catalog of type 2 quasars from the Sloan Digital Sky Survey (SDSS), selected based on their optical emission lines. The catalog contains 887 objects with redshifts z < 0.83; this is six times larger than the previous version and is by far the largest sample of type 2 quasars in the literature. We derive the [OIII]5008 luminosity function for...

  8. Magneto-optical imaging of transport current densities in superconductors

    International Nuclear Information System (INIS)

    Crabtree, G.W.; Welp, U.; Gunter, D.O.; Zhong, W.; Balachandran, U.; Haldar, P.; Sokolowski, R.S.; Vlasko-Vlasov, V.K.; Nikitenko, V.I.

    1995-01-01

    Direct imaging of the paths of transport currents in superconductors creates many new possibilities for exploring the basic features of vortex pinning mechanisms and for improving the performance of superconducting materials. A technique for imaging the path and magnitude of the transport current density flowing in superconductors is described. Results are given for a 37-filament BSCCO 2223 powder-in-tube wire, showing a highly inhomogeneous current path within the filaments

  9. Electronic and optical properties of nanocrystalline WO3 thin films studied by optical spectroscopy and density functional calculations

    International Nuclear Information System (INIS)

    Johansson, Malin B; Niklasson, Gunnar A; Österlund, Lars; Baldissera, Gustavo; Persson, Clas; Valyukh, Iryna; Arwin, Hans

    2013-01-01

    The optical and electronic properties of nanocrystalline WO 3 thin films prepared by reactive dc magnetron sputtering at different total pressures (P tot ) were studied by optical spectroscopy and density functional theory (DFT) calculations. Monoclinic films prepared at low P tot show absorption in the near infrared due to polarons, which is attributed to a strained film structure. Analysis of the optical data yields band-gap energies E g ≈ 3.1 eV, which increase with increasing P tot by 0.1 eV, and correlate with the structural modifications of the films. The electronic structures of triclinic δ-WO 3 , and monoclinic γ- and ε-WO 3 were calculated using the Green function with screened Coulomb interaction (GW approach), and the local density approximation. The δ-WO 3 and γ-WO 3 phases are found to have very similar electronic properties, with weak dispersion of the valence and conduction bands, consistent with a direct band-gap. Analysis of the joint density of states shows that the optical absorption around the band edge is composed of contributions from forbidden transitions (>3 eV) and allowed transitions (>3.8 eV). The calculations show that E g in ε-WO 3 is higher than in the δ-WO 3 and γ-WO 3 phases, which provides an explanation for the P tot dependence of the optical data. (paper)

  10. Electronic and optical properties of nanocrystalline WO3 thin films studied by optical spectroscopy and density functional calculations

    Science.gov (United States)

    Johansson, Malin B.; Baldissera, Gustavo; Valyukh, Iryna; Persson, Clas; Arwin, Hans; Niklasson, Gunnar A.; Österlund, Lars

    2013-05-01

    The optical and electronic properties of nanocrystalline WO3 thin films prepared by reactive dc magnetron sputtering at different total pressures (Ptot) were studied by optical spectroscopy and density functional theory (DFT) calculations. Monoclinic films prepared at low Ptot show absorption in the near infrared due to polarons, which is attributed to a strained film structure. Analysis of the optical data yields band-gap energies Eg ≈ 3.1 eV, which increase with increasing Ptot by 0.1 eV, and correlate with the structural modifications of the films. The electronic structures of triclinic δ-WO3, and monoclinic γ- and ε-WO3 were calculated using the Green function with screened Coulomb interaction (GW approach), and the local density approximation. The δ-WO3 and γ-WO3 phases are found to have very similar electronic properties, with weak dispersion of the valence and conduction bands, consistent with a direct band-gap. Analysis of the joint density of states shows that the optical absorption around the band edge is composed of contributions from forbidden transitions (>3 eV) and allowed transitions (>3.8 eV). The calculations show that Eg in ε-WO3 is higher than in the δ-WO3 and γ-WO3 phases, which provides an explanation for the Ptot dependence of the optical data.

  11. High densities and optical collisions in a two-colour magneto-optical trap for metastable helium

    NARCIS (Netherlands)

    Koelemeij, J.C.J.; Tychkov, A.; Jeltes, T.; Hogervorst, W.; Vassen, W.

    2004-01-01

    We have studied a cloud of cold metastable helium (He*) atoms interacting with near-resonant light at 1083 nm and 389 nm. The 1083 nm light allows for efficient loading of a large magneto-optical trap (MOT) and the 389 nm light is subsequently used to increase the density and reduce the temperature

  12. The local density of optical states of a metasurface

    Science.gov (United States)

    Lunnemann, Per; Koenderink, A. Femius

    2016-02-01

    While metamaterials are often desirable for near-field functions, such as perfect lensing, or cloaking, they are often quantified by their response to plane waves from the far field. Here, we present a theoretical analysis of the local density of states near lattices of discrete magnetic scatterers, i.e., the response to near field excitation by a point source. Based on a pointdipole theory using Ewald summation and an array scanning method, we can swiftly and semi-analytically evaluate the local density of states (LDOS) for magnetoelectric point sources in front of an infinite two-dimensional (2D) lattice composed of arbitrary magnetoelectric dipole scatterers. The method takes into account radiation damping as well as all retarded electrodynamic interactions in a self-consistent manner. We show that a lattice of magnetic scatterers evidences characteristic Drexhage oscillations. However, the oscillations are phase shifted relative to the electrically scattering lattice consistent with the difference expected for reflection off homogeneous magnetic respectively electric mirrors. Furthermore, we identify in which source-surface separation regimes the metasurface may be treated as a homogeneous interface, and in which homogenization fails. A strong frequency and in-plane position dependence of the LDOS close to the lattice reveals coupling to guided modes supported by the lattice.

  13. Lectures on light nonlinear and quantum optics using the density matrix

    CERN Document Server

    Rand, Stephen C.

    2016-01-01

    This book bridges the gap between introductory quantum mechanics and the research front of modern optics and scientific fields that make use of light. While suitable as a reference for the specialist in quantum optics, it also targets non-specialists from other disciplines who need to understand light and its uses in research. It introduces a single analytic tool, the density matrix, to analyze complex optical phenomena encountered in traditional as well as cross-disciplinary research. It moves swiftly in a tight sequence from elementary to sophisticated topics in quantum optics, including optical tweezers, laser cooling, coherent population transfer, optical magnetism, electromagnetically induced transparency, squeezed light, and cavity quantum electrodynamics. A systematic approach starts with the simplest systems—stationary two-level atoms—then introduces atomic motion, adds more energy levels, and moves on to discuss first-, second-, and third-order coherence effects that are the basis for analyzing n...

  14. Reduction of damage initiation density in fused silica optics via UV laser conditioning

    Science.gov (United States)

    Peterson, John E.; Maricle, Stephen M.; Brusasco, Raymond M.; Penetrante, Bernardino M.

    2004-03-16

    The present invention provides a method for reducing the density of sites on the surface of fused silica optics that are prone to the initiation of laser-induced damage, resulting in optics which have far fewer catastrophic defects and are better capable of resisting optical deterioration upon exposure for a long period of time to a high-power laser beam having a wavelength of about 360 nm or less. The initiation of laser-induced damage is reduced by conditioning the optic at low fluences below levels that normally lead to catastrophic growth of damage. When the optic is then irradiated at its high fluence design limit, the concentration of catastrophic damage sites that form on the surface of the optic is greatly reduced.

  15. Microscopic optical potentials derived from ab initio translationally invariant nonlocal one-body densities

    Science.gov (United States)

    Gennari, Michael; Vorabbi, Matteo; Calci, Angelo; Navrátil, Petr

    2018-03-01

    Background: The nuclear optical potential is a successful tool for the study of nucleon-nucleus elastic scattering and its use has been further extended to inelastic scattering and other nuclear reactions. The nuclear density of the target nucleus is a fundamental ingredient in the construction of the optical potential and thus plays an important role in the description of the scattering process. Purpose: In this paper we derive a microscopic optical potential for intermediate energies using ab initio translationally invariant nonlocal one-body nuclear densities computed within the no-core shell model (NCSM) approach utilizing two- and three-nucleon chiral interactions as the only input. Methods: The optical potential is derived at first order within the spectator expansion of the nonrelativistic multiple scattering theory by adopting the impulse approximation. Nonlocal nuclear densities are derived from the NCSM one-body densities calculated in the second quantization. The translational invariance is generated by exactly removing the spurious center-of-mass (COM) component from the NCSM eigenstates. Results: The ground-state local and nonlocal densities of He 4 ,6 ,8 , 12C, and 16O are calculated and applied to optical potential construction. The differential cross sections and the analyzing powers for the elastic proton scattering off these nuclei are then calculated for different values of the incident proton energy. The impact of nonlocality and the COM removal is discussed. Conclusions: The use of nonlocal densities has a substantial impact on the differential cross sections and improves agreement with experiment in comparison to results generated with the local densities especially for light nuclei. For the halo nuclei 6He and 8He, the results for the differential cross section are in a reasonable agreement with the data although a more sophisticated model for the optical potential is required to properly describe the analyzing powers.

  16. Serum prolactin concentrations in relation to hypopituitarism and obesity in children with optic nerve hypoplasia.

    Science.gov (United States)

    Vedin, Amy M; Garcia-Filion, Pamela; Fink, Cassandra; Borchert, Mark; Geffner, Mitchell E

    2012-01-01

    The majority of children with optic nerve hypoplasia (ONH) develop hypopituitarism and many also become obese. These associated conditions are a major cause of morbidity and are possibly due to hypothalamic dysfunction. Because mild hyperprolactinemia often occurs in subjects with disorders of the hypothalamus, we examined whether hyperprolactinemia was present in children with ONH during the first 3 years of life and whether it was a marker for hypopituitarism and/or obesity. Data were retrospectively analyzed from a registry study of children with ONH. The initial serum prolactin was obtained prior to age 36 months (n = 125) and compared with pituitary function and body mass index at age 5. 72% of subjects had an elevated initial serum prolactin and 60% had hypopituitarism. An elevated initial prolactin was associated with hypopituitarism (OR 2.58; 95% CI 1.16, 5.73), specifically with growth hormone deficiency (OR 2.77; 95% CI 1.21, 6.34). 31% of subjects had a body mass index ≥ 85th percentile, but this did not correlate with initial hyperprolactinemia. Early hyperprolactinemia correlates with the presence of hypopituitarism in children with ONH, but it is not a reliable prognosticator of hypopituitarism. Additionally, hyperprolactinemia does not predict future weight excess. Copyright © 2012 S. Karger AG, Basel.

  17. Next-generation fabrication technologies for optical pickup devices in high-density optical disk storage systems

    Science.gov (United States)

    Hosoe, Shigeru

    1999-05-01

    This paper shows a direction of friction technologies to make aspherical plastic objective lens with higher optical performance for high density optical disk storage systems. Specifically, a low birefringence and low water absorption (less than 0.1%) optical resin, low tool abrasion mold material, high circularity diamond tool which nose circularity is less than 30 nm, and 1 nm axis resolution precision lathe which tool position is stabilized against drift by environmental change are referred. Cut optical surface of a mold sample was constantly attained in less than 5 nmRtm surface roughness. Using these new technologies, aspherical plastic objective lens (NA0.6) for DVD which wave aberration is less than 35 m (lambda) rms was realized.

  18. Serum oxidized low-density lipoprotein level as a marker of oxidative stress in patients undergoing hyperbaric oxygen therapy.

    Science.gov (United States)

    Keskin, Kudret; Kilci, Hakan; Aksan, Gökhan; Çetinkal, Gökhan; Yıldız, Süleyman Sezai; Kocaman Türk, Füsun; Bingöl, Gülsüm

    2017-09-01

    Oxidative stress (OS) is involved in the pathogenesis of atherosclerosis. Hyperbaric oxygen therapy (HBOT), in which 100% oxygen is inhaled under hyperbaric pressure, may create OS. Therefore, the aim of this research was to measure the serum oxidized low-density lipoprotein (oxLDL) level in patients undergoing HBOT. Twenty-nine patients who underwent HBOT to treat various diseases were enrolled in this study. The serum oxLDL level was measured at the beginning of the first and after the 10th therapy session. There was no significant difference between the oxLDL level of patients before and after HBOT (4.96±0.1 vs. 4.94±0.1 U/mL; p=0.36). HBOT seems to be safe in terms of oxLDL production up to 10 sessions. However, further large-scale studies investigating longer duration of HBOT treatment are required to understand the role of OS.

  19. Comparison of soymilk and probiotic soymilk effects on serum high-density lipoprotein cholesterol and low-density lipoprotein cholesterol in diabetic Wistar rats

    Directory of Open Access Journals (Sweden)

    Mina Babashahi

    2015-04-01

    Full Text Available BACKGROUND: Soy milk (SM and its fermented products are identified as rich sources of bioactive compounds helping to manage and to reduce the risk of chronic disease. This study aimed to compare the effects of SM and probiotic SM (PSM consumption on serum low-density lipoprotein cholesterol (LDL-C and high-density lipoprotein cholesterol (HDL-C in diabetic Wistar rats. METHODS: Probiotic SM was prepared by fermentation of the plain SM with a native strain of Lactobacillus plantarum. 20 streptozotocin-nicotinamide-induced diabetic Wistar rats were divided into two groups based on the type of administered SM (SM group and PSM group. The animals were fed with 1 ml/day of either soy or PSM for 21 days. The serum lipoprotein levels were analyzed at baseline and the end of the intervention period. RESULTS: HDL-C increased significantly in PSM group. Furthermore, this group showed more percent of change in increased HDL-C in compression with SM group (P < 0.050. Regarding LDL-C level, rats fed with SM was not significantly different from the PSM group (P < 0.050; though, this biomarker was reduced in both group. CONCLUSION: Probiotic SM could modulate blood lipoprotein levels. Thus, it may be considered in managing diabetes complications and atherosclerotic risks. 

  20. Fog Density Estimation and Image Defogging Based on Surrogate Modeling for Optical Depth.

    Science.gov (United States)

    Jiang, Yutong; Sun, Changming; Zhao, Yu; Yang, Li

    2017-05-03

    In order to estimate fog density correctly and to remove fog from foggy images appropriately, a surrogate model for optical depth is presented in this paper. We comprehensively investigate various fog-relevant features and propose a novel feature based on the hue, saturation, and value color space which correlate well with the perception of fog density. We use a surrogate-based method to learn a refined polynomial regression model for optical depth with informative fog-relevant features such as dark-channel, saturation-value, and chroma which are selected on the basis of sensitivity analysis. Based on the obtained accurate surrogate model for optical depth, an effective method for fog density estimation and image defogging is proposed. The effectiveness of our proposed method is verified quantitatively and qualitatively by the experimental results on both synthetic and real-world foggy images.

  1. Electron beam manipulation, injection and acceleration in plasma wakefield accelerators by optically generated plasma density spikes

    Energy Technology Data Exchange (ETDEWEB)

    Wittig, Georg; Karger, Oliver S.; Knetsch, Alexander [Institute of Experimental Physics, University of Hamburg, 22761 Hamburg (Germany); Xi, Yunfeng; Deng, Aihua; Rosenzweig, James B. [Particle Beam Physics Laboratory, UCLA, Los Angeles, CA 90095 (United States); Bruhwiler, David L. [RadiaSoft LLC, Boulder, CO 80304 (United States); RadiaBeam Technologies LLC (United States); Smith, Jonathan [Tech-X UK Ltd, Daresbury, Cheshire WA4 4FS (United Kingdom); Sheng, Zheng-Ming; Jaroszynski, Dino A.; Manahan, Grace G. [Physics Department, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Hidding, Bernhard [Institute of Experimental Physics, University of Hamburg, 22761 Hamburg (Germany); Physics Department, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom)

    2016-09-01

    We discuss considerations regarding a novel and robust scheme for optically triggered electron bunch generation in plasma wakefield accelerators [1]. In this technique, a transversely propagating focused laser pulse ignites a quasi-stationary plasma column before the arrival of the plasma wake. This localized plasma density enhancement or optical “plasma torch” distorts the blowout during the arrival of the electron drive bunch and modifies the electron trajectories, resulting in controlled injection. By changing the gas density, and the laser pulse parameters such as beam waist and intensity, and by moving the focal point of the laser pulse, the shape of the plasma torch, and therefore the generated trailing beam, can be tuned easily. The proposed method is much more flexible and faster in generating gas density transitions when compared to hydrodynamics-based methods, and it accommodates experimentalists needs as it is a purely optical process and straightforward to implement.

  2. Single exosome detection in serum using microtoroid optical resonators (Conference Presentation)

    Science.gov (United States)

    Su, Judith

    2016-03-01

    Recently exosomes have attracted interest due to their potential as cancer biomarkers. We report the real time, label-free sensing of single exosomes in serum using microtoroid optical resonators. We use this approach to assay the progression of tumors implanted in mice by specifically detecting low concentrations of tumor-derived exosomes. Our approach measures the adsorption of individual exosomes onto a functionalized silica microtoroid by tracking changes in the optical resonant frequency of the microtoroid. When exosomes land on the microtoroid, they perturb its refractive index in the evanescent field and thus shift its resonance frequency. Through digital frequency locking, we are able to rapidly track these shifts with accuracies of better than 10 attometers (one part in 10^11). Samples taken from tumor-implanted mice from later weeks generated larger frequency shifts than those from earlier weeks. Control samples taken from a mouse with no tumor generated no such increase in signal between subsequent weeks. Analysis of shifts from tumor-implanted mouse samples show a distribution of unitary steps, with the maximum step having a height of ~1.2 fm, corresponding to an exosome size of 44 ± 4.8 nm. This size range corresponds to that found by performing nanoparticle tracking analysis on the same samples. Our results demonstrate development towards a minimally-invasive tumor "biopsy" that eliminates the need to find and access a tumor.

  3. Mapping the Local Density of Optical States of a Photonic Crystal with Single Quantum Dots

    DEFF Research Database (Denmark)

    Wang, Qin; Stobbe, Søren; Lodahl, Peter

    2011-01-01

    We use single self-assembled InGaAs quantum dots as internal probes to map the local density of optical states of photonic crystal membranes. The employed technique separates contributions from nonradiative recombination and spin-flip processes by properly accounting for the role of the exciton...... fine structure. We observe inhibition factors as high as 70 and compare our results to local density of optical states calculations available from the literature, thereby establishing a quantitative understanding of photon emission in photonic crystal membranes. © 2011 American Physical Society....

  4. Changes of bone density and serum osteocalcin levels in mid and late pregnancy

    International Nuclear Information System (INIS)

    Qiu Jianmin; Hu Yafen

    1998-01-01

    Single photon bone densitometer has been used to determine the bone mineral contents in 1521 cases of mid and late pregnant women. The results showed that the contents are significantly lower than the normal group (P<0.001). Varying degrees of bone mineral loss took place in 488 cases (32.1%) of pregnant women. Serum osteocalcin (BGP) levels in 40 cases of normal nonpregnant women and 41 cases of the bone mineral loss group of pregnant women have been measured simultaneously. The results showed that the contents of the bone mineral loss group of pregnant women are obviously lower than the normal group (P<0.001). This fact implies that the determinations of single photon bone densitometer and serum BGP RIA can be used as the indices for assessing the bone mineral loss in pregnant women

  5. A novel method to create high density stratification with matching refractive index for optical flow investigations

    Science.gov (United States)

    Krohn, Benedikt; Manera, Annalisa; Petrov, Victor

    2018-04-01

    Turbulent mixing in stratified environments represents a challenging task in experimental turbulence research, especially when large density gradients are desired. When optical measurement techniques like particle image velocimetry (PIV) are applied to stratified liquids, it is common practice to combine two aqueous solutions with different density but equal refractive index, to suppress particle image deflections. While refractive image matching (RIM) has been developed in the late 1970s, the achieved limit of 4% density ratio was not rivalled up to day. In the present work, we report a methodology, based on the behavior of excess properties and their change in a multicomponent system while mixing, that allows RIM for solutions with higher density differences. The methodology is then successfully demonstrated using a ternary combination of water, isopropanol and glycerol, for which RIM in presence of a density ratio of 8.6% has been achieved. Qualitative PIV results of a turbulent buoyant jet with 8.6% density ratio are shown.

  6. Measurement of the optical density of packable composites: comparison between direct and indirect digital systems

    Directory of Open Access Journals (Sweden)

    Graziottin Luiz Felipe Rodrigues

    2002-01-01

    Full Text Available The aim of this study was to measure the optical density of four packable composite resins with widths of 1, 2, 3 and 4 mm, by means of Digora® (direct and DentScan DentView® (indirect digital imaging systems, in order to compare both methods. Twenty acrylic plates, with the proposed thicknesses, were used, each one containing a sample of each resin. Each acrylic plate was radiographed three times, under a standardized technique. For the Digora® system, an optical plate was used under each resin sample, and, for the DentScan DentView® system, occlusal films were employed, totalizing 60 exposures for each system. Optical plates and films were scanned and three consecutive optical readouts were carried out, totalizing 1,440 readouts. The results were submitted to statistical analysis and revealed that the average optical density of the four resins always increased as thickness increased. Regarding the comparisons between the composite resins, in both analysis the resin with the greater optical density was SurefilTM followed by ProdigyTM Condensable, AlertTM and Solitaire®. The correlations between the results of Digora® and DentScan DentView® were significant for the different thicknesses and materials. The observed tendency is that as the values obtained with the Digora® system increase, so do the values obtained with DentScan DentView®. While thickness increased, the values of optical density in both Digora® and DentScan DentView® tended to approach each other. The Digora® system presented smaller amplitude between the results obtained in adjacent thicknesses.

  7. Effect of Target Density on Microstructural, Electrical, and Optical Properties of Indium Tin Oxide Thin Films

    Science.gov (United States)

    Zhu, Guisheng; Zhi, Li; Yang, Huijuan; Xu, Huarui; Yu, Aibing

    2012-09-01

    In this paper, indium tin oxide (ITO) targets with different densities were used to deposit ITO thin films. The thin films were deposited from these targets at room temperature and annealed at 750°C. Microstructural, electrical, and optical properties of the as-prepared films were studied. It was found that the target density had no effect on the properties or deposition rate of radiofrequency (RF)-sputtered ITO thin films, different from the findings for direct current (DC)-sputtered films. Therefore, when using RF sputtering, the target does not require a high density and may be reused.

  8. Modelling of the energy density deposition profiles of ultrashort laser pulses focused in optical media

    International Nuclear Information System (INIS)

    Vidal, F; Lavertu, P-L; Bigaouette, N; Moore, F; Brunette, I; Giguere, D; Kieffer, J-C; Olivie, G; Ozaki, T

    2007-01-01

    The propagation of ultrashort laser pulses in dense optical media is investigated theoretically by solving numerically the nonlinear Schroedinger equation. It is shown that the maximum energy density deposition as a function of the pulse energy presents a well-defined threshold that increases with the pulse duration. As a consequence of plasma defocusing, the maximum energy density deposition is generally smaller and the size of the energy deposition zone is generally larger for shorter pulses. Nevertheless, significant values of the energy density deposition can be obtained near threshold, i.e., at lower energy than for longer pulses

  9. Accurate Prediction of Transimpedances and Equivalent Input Noise Current Densities of Tuned Optical Receiver Front Ends

    DEFF Research Database (Denmark)

    Liu, Qing Zhong

    1991-01-01

    Novel analytical expressions have been derived for calculating transimpedances and equivalent input noise current densities of five tuned optical receiver front ends based on PIN diode and MESFETs or HEMTs. Miller's capacitance, which has been omitted in previous studies, has been taken...

  10. Simulation of Space Charge Effects in Electron Optical System Based on the Calculations of Current Density

    Czech Academy of Sciences Publication Activity Database

    Zelinka, Jiří; Oral, Martin; Radlička, Tomáš

    2015-01-01

    Roč. 21, S4 (2015), s. 246-251 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : electron optical system * calculations of current density Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  11. Macular pigment optical density in the elderly: findings in a large biracial Midsouth population sample

    NARCIS (Netherlands)

    Iannaccone, Alessandro; Mura, Marco; Gallaher, Kevin T.; Johnson, Elizabeth J.; Todd, William Andrew; Kenyon, Emily; Harris, Tarsha L.; Harris, Tamara; Satterfield, Suzanne; Johnson, Karen C.; Kritchevsky, Stephen B.

    2007-01-01

    PURPOSE: To report the macular pigment optical density (MPOD) findings at 0.5 degrees of eccentricity from the fovea in elderly subjects participating in ARMA, a study of aging and age-related maculopathy (ARM) ancillary to the Health, Aging, and Body Composition (Health ABC) Study. METHODS: MPOD

  12. Identification and mapping of linear antibody epitopes in human serum albumin using high-density Peptide arrays.

    Directory of Open Access Journals (Sweden)

    Lajla Bruntse Hansen

    Full Text Available We have recently developed a high-density photolithographic, peptide array technology with a theoretical upper limit of 2 million different peptides per array of 2 cm(2. Here, we have used this to perform complete and exhaustive analyses of linear B cell epitopes of a medium sized protein target using human serum albumin (HSA as an example. All possible overlapping 15-mers from HSA were synthesized and probed with a commercially available polyclonal rabbit anti-HSA antibody preparation. To allow for identification of even the weakest epitopes and at the same time perform a detailed characterization of key residues involved in antibody binding, the array also included complete single substitution scans (i.e. including each of the 20 common amino acids at each position of each 15-mer peptide. As specificity controls, all possible 15-mer peptides from bovine serum albumin (BSA and from rabbit serum albumin (RSA were included as well. The resulting layout contained more than 200.000 peptide fields and could be synthesized in a single array on a microscope slide. More than 20 linear epitope candidates were identified and characterized at high resolution i.e. identifying which amino acids in which positions were needed, or not needed, for antibody interaction. As expected, moderate cross-reaction with some peptides in BSA was identified whereas no cross-reaction was observed with peptides from RSA. We conclude that high-density peptide microarrays are a very powerful methodology to identify and characterize linear antibody epitopes, and should advance detailed description of individual specificities at the single antibody level as well as serologic analysis at the proteome-wide level.

  13. Identification and mapping of linear antibody epitopes in human serum albumin using high-density Peptide arrays.

    Science.gov (United States)

    Hansen, Lajla Bruntse; Buus, Soren; Schafer-Nielsen, Claus

    2013-01-01

    We have recently developed a high-density photolithographic, peptide array technology with a theoretical upper limit of 2 million different peptides per array of 2 cm(2). Here, we have used this to perform complete and exhaustive analyses of linear B cell epitopes of a medium sized protein target using human serum albumin (HSA) as an example. All possible overlapping 15-mers from HSA were synthesized and probed with a commercially available polyclonal rabbit anti-HSA antibody preparation. To allow for identification of even the weakest epitopes and at the same time perform a detailed characterization of key residues involved in antibody binding, the array also included complete single substitution scans (i.e. including each of the 20 common amino acids) at each position of each 15-mer peptide. As specificity controls, all possible 15-mer peptides from bovine serum albumin (BSA) and from rabbit serum albumin (RSA) were included as well. The resulting layout contained more than 200.000 peptide fields and could be synthesized in a single array on a microscope slide. More than 20 linear epitope candidates were identified and characterized at high resolution i.e. identifying which amino acids in which positions were needed, or not needed, for antibody interaction. As expected, moderate cross-reaction with some peptides in BSA was identified whereas no cross-reaction was observed with peptides from RSA. We conclude that high-density peptide microarrays are a very powerful methodology to identify and characterize linear antibody epitopes, and should advance detailed description of individual specificities at the single antibody level as well as serologic analysis at the proteome-wide level.

  14. Glaucoma Diagnostic Ability of the Optical Coherence Tomography Angiography Vessel Density Parameters.

    Science.gov (United States)

    Chung, Jae Keun; Hwang, Young Hoon; Wi, Jae Min; Kim, Mijin; Jung, Jong Jin

    2017-11-01

    To investigate the glaucoma diagnostic abilities of vessel density parameters as determined by optical coherence tomography (OCT) angiography in different stages of glaucoma. A total of 113 healthy eyes and 140 glaucomatous eyes were enrolled. Diagnostic abilities of the OCT vessel density parameters in the optic nerve head (ONH), peripapillary, and macular regions were evaluated by calculating the area under the receiver operation characteristic curves (AUCs). AUCs of the peripapillary vessel density parameters and circumpapillary retinal nerve fiber layer (RNFL) thickness were compared. OCT angiography vessel densities in the ONH, peripapillary, and macular regions in the glaucomatous eyes were significantly lower than those in the healthy eyes (P glaucoma detection. The peripapillary vessel density parameters showed similar AUCs with the corresponding sectoral RNFL thickness (P > 0.05). However, in the early stage of glaucoma, the AUCs of the inferotemporal and temporal peripapillary vessel densities were significantly lower than that of the RNFL thickness (P glaucoma diagnostic ability with circumpapillary RNFL thickness, in the early stage, the vessel density parameters showed limited clinical value.

  15. Predicting Intra-Urban Population Densities in Africa using SAR and Optical Remote Sensing Data

    Science.gov (United States)

    Linard, C.; Steele, J.; Forget, Y.; Lopez, J.; Shimoni, M.

    2017-12-01

    The population of Africa is predicted to double over the next 40 years, driving profound social, environmental and epidemiological changes within rapidly growing cities. Estimations of within-city variations in population density must be improved in order to take urban heterogeneities into account and better help urban research and decision making, especially for vulnerability and health assessments. Satellite remote sensing offers an effective solution for mapping settlements and monitoring urbanization at different spatial and temporal scales. In Africa, the urban landscape is covered by slums and small houses, where the heterogeneity is high and where the man-made materials are natural. Innovative methods that combine optical and SAR data are therefore necessary for improving settlement mapping and population density predictions. An automatic method was developed to estimate built-up densities using recent and archived optical and SAR data and a multi-temporal database of built-up densities was produced for 48 African cities. Geo-statistical methods were then used to study the relationships between census-derived population densities and satellite-derived built-up attributes. Best predictors were combined in a Random Forest framework in order to predict intra-urban variations in population density in any large African city. Models show significant improvement of our spatial understanding of urbanization and urban population distribution in Africa in comparison to the state of the art.

  16. The effect of ingestion of egg and low density lipoprotein (LDL oxidation on serum lipid profiles in hypercholesterolemic women

    Directory of Open Access Journals (Sweden)

    Taweesak Techakriengkrai1

    2012-04-01

    Full Text Available Egg is a major source of dietary cholesterol. The serum lipid response to egg shows marked individual variation, beingpartly genetically determined, and influence by ethnic groups and the overall diet response. In the present investigation, weinvestigated the effect of ingestion of egg and low density lipoprotein (LDL oxidation on serum lipid profile in hypercholesterolemicwomen. Forty hypercholesterolemic women volunteers on a cholesterol-lowering diet (CLD divided into 2 groups ina randomized controlled cross-over study of one egg per day (CLD + 1 egg for 4-week and three eggs per day (CLD + 3 eggsfor 4-week, separated by 4-week period egg-free. The body weight, blood pressure, serum lipid profiles and LDL oxidationwere measured at 4-week intervals. Cholesterol-lowering diet was applied throughout the study by a dietitian using a foodexchange program and 3-day dietary recall every 4 weeks. Compared to the values obtained at baseline, the mean serum totalcholesterol and LDL cholesterol of CLD + 3 eggs was not significantly different from baseline whereas of those of 4-week ofegg-free period and CLD + 1 egg were significantly decreased (238.3±2.9 mg/dL and 228.3±4.7 mg/dL compared to thebaseline (252.2±5.9 mg/dL as was LDL cholesterol (161.2±3.0 mg/dL and 155.7±4.8 mg/dL compared to the baseline (177.5±6.0 mg/dL (p<0.05. The study showed there were no significantly difference the body weight, blood pressure, HDL cholesterol,triglycerides or LDL oxidation during the study. However, serum total cholesterol and LDL cholesterol of 1 or 3 eggsper day after 4-week of egg consumption was not significantly higher than the egg-free period. The study suggests that inhypercholesterolemic women who are on cholesterol-lowering diet, consuming one or three eggs per day did not raise serumcholesterol or LDL cholesterol levels at 4 weeks or result in any change in LDL oxidation.

  17. Calculation of the local optical density of states in absorbing and gain media

    International Nuclear Information System (INIS)

    Di Stefano, O; Fina, N; Savasta, S; Girlanda, R; Pieruccini, M

    2010-01-01

    The local optical density of states plays a key role in a wide range of phenomena. Near to structures displaying optical absorption or gain, the definition of the photonic local density of states needs to be revised. In this case two operative different definitions can be adopted to characterize photonic structures. The first (ρ A (r, ω)) describes the light intensity at a point r when the material system is illuminated isotropically and corresponds to what can be measured by a near-field microscope. The second (ρ B (r, ω)) gives a measure of vacuum fluctuations and coincides with ρ A (r, ω) in systems with real susceptibility. Scattering calculations in the presence of dielectric and metallic nanostructures show that these two definitions can give rather different results, the difference being proportional to the thermal emission power of the photonic structure. We present a detailed derivation of this result and numerical calculations for nanostructures displaying optical gain. In the presence of amplifying media, ρ B (r, ω) displays regions with negative photon densities, thus failing in describing a power signal. In contrast, ρ A (r, ω), positive definite, properly describes the near-field optical properties of these structures.

  18. Serum amyloid A stimulates macrophage foam cell formation via lectin-like oxidized low-density lipoprotein receptor 1 upregulation

    International Nuclear Information System (INIS)

    Lee, Ha Young; Kim, Sang Doo; Baek, Suk-Hwan; Choi, Joon Hyuk; Cho, Kyung-Hyun; Zabel, Brian A.; Bae, Yoe-Sik

    2013-01-01

    Highlights: ► SAA induced macrophage foam cell formation. ► SAA stimulated upregulation of lectin-like oxidized low-density lipoprotein receptor 1 (LOX1). ► SAA-induced LOX1 expression and foam cell formation is mediated by JNK/NF-κB signaling. ► HDL-conjugated SAA also stimulates foam cell formation via LOX1 upregulation. ► The finding reveals a novel mechanism of action of SAA in the pathogenesis of atherosclerosis. -- Abstract: Elevated levels of serum amyloid A (SAA) is a risk factor for cardiovascular diseases, however, the role of SAA in the pathophysiology of atherosclerosis remains unclear. Here we show that SAA induced macrophage foam cell formation. SAA-stimulated foam cell formation was mediated by c-jun N-terminal kinase (JNK) signaling. Moreover, both SAA and SAA-conjugated high density lipoprotein stimulated the expression of the important scavenger receptor lectin-like oxidized low-density lipoprotein receptor 1 (LOX1) via nuclear factor-κB (NF-κB). A LOX1 antagonist carrageenan significantly blocked SAA-induced foam cell formation, indicating that SAA promotes foam cell formation via LOX1 expression. Our findings therefore suggest that SAA stimulates foam cell formation via LOX1 induction, and thus likely contributes to atherogenesis

  19. Effect of chromium chloride supplementation on glucose tolerance and serum lipids including high-density lipoprotein of adult men.

    Science.gov (United States)

    Riales, R; Albrink, M J

    1981-12-01

    Chromium deficiency may cause insulin resistance, hyperinsulinemia, impaired glucose tolerance, and hyperlipidemia, recovered by chromium supplementation. The effect of chromium supplementation on serum lipids and glucose tolerance was tested in a double-blind 12-wk study of 23 healthy adult men aged 31 to 60 yr. Either 200 micrograms trivalent chromium in 5 ml water (Cr) or 5 ml plain water (W) was ingested daily 5 days each week. Half the subjects volunteered for glucose tolerance tests with insulin levels. At 12 wk high-density lipoprotein cholesterol increased in the Cr group from 35 to 39 mg/dl (p less than 0.05) but did not change in the water group (34 mg/dl). The largest increase in high-density lipoprotein cholesterol and decreases in insulin and glucose were found in those subjects having normal glucose levels together with elevated insulin levels at base-line. The data are thus consistent with the hypothesis that Cr supplementation raises high-density lipoprotein cholesterol and improves insulin sensitivity in those with evidence of insulin resistance but normal glucose tolerance.

  20. Serum amyloid A stimulates macrophage foam cell formation via lectin-like oxidized low-density lipoprotein receptor 1 upregulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ha Young, E-mail: hayoung@skku.edu [Department of Biological Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Mitochondria Hub Regulation Center, Dong-A University, Busan 602-714 (Korea, Republic of); Kim, Sang Doo [Department of Biological Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Baek, Suk-Hwan [Department of Biochemistry and Molecular Biology, College of Medicine, Yeungnam University, Daegu 705-717 (Korea, Republic of); Choi, Joon Hyuk [Department of Pathology, College of Medicine, Yeungnam University, Daegu 705-717 (Korea, Republic of); Cho, Kyung-Hyun [School of Biotechnology, Yeungnam University, Gyeongsan 712-749 (Korea, Republic of); Zabel, Brian A. [Palo Alto Institute for Research and Education, Veterans Affairs Hospital, Palo Alto, CA 94304 (United States); Bae, Yoe-Sik, E-mail: yoesik@skku.edu [Department of Biological Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Mitochondria Hub Regulation Center, Dong-A University, Busan 602-714 (Korea, Republic of); Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul 135-710 (Korea, Republic of)

    2013-03-29

    Highlights: ► SAA induced macrophage foam cell formation. ► SAA stimulated upregulation of lectin-like oxidized low-density lipoprotein receptor 1 (LOX1). ► SAA-induced LOX1 expression and foam cell formation is mediated by JNK/NF-κB signaling. ► HDL-conjugated SAA also stimulates foam cell formation via LOX1 upregulation. ► The finding reveals a novel mechanism of action of SAA in the pathogenesis of atherosclerosis. -- Abstract: Elevated levels of serum amyloid A (SAA) is a risk factor for cardiovascular diseases, however, the role of SAA in the pathophysiology of atherosclerosis remains unclear. Here we show that SAA induced macrophage foam cell formation. SAA-stimulated foam cell formation was mediated by c-jun N-terminal kinase (JNK) signaling. Moreover, both SAA and SAA-conjugated high density lipoprotein stimulated the expression of the important scavenger receptor lectin-like oxidized low-density lipoprotein receptor 1 (LOX1) via nuclear factor-κB (NF-κB). A LOX1 antagonist carrageenan significantly blocked SAA-induced foam cell formation, indicating that SAA promotes foam cell formation via LOX1 expression. Our findings therefore suggest that SAA stimulates foam cell formation via LOX1 induction, and thus likely contributes to atherogenesis.

  1. WDR1 and CLNK gene polymorphisms correlate with serum glucose and high-density lipoprotein levels in Tibetan gout patients.

    Science.gov (United States)

    Lan, Bing; Chen, Peng; Jiri, Mutu; He, Na; Feng, Tian; Liu, Kai; Jin, Tianbo; Kang, Longli

    2016-03-01

    Current evidence suggests heredity and metabolic syndrome contributes to gout progression. Specifically, the WDR1 and CLNK genes may play a role in gout progression in European ancestry populations. However, no studies have focused on Chinese populations, especially Tibetan individuals. This study aims to determine whether variations in these two genes correlate with gout-related indices in Chinese-Tibetan gout patients. Eleven single-nucleotide polymorphisms in the WDR1 and CLNK genes were detected in 319 Chinese-Tibetan gout patients and 318 controls. We used one-way analysis of variance to evaluate the polymorphisms' effects on gout based on mean serum levels of metabolism indicators, such as albumin, glucose (GLU), triglycerides, cholesterol, high-density lipoproteins (HDL-C), creatinine, and uric acid, from fasting venous blood samples. All p values were Bonferroni corrected. Polymorphisms of the WDR1 and CLNK genes affected multiple risk factors for gout development. Significant differences in serum GLU levels were detected between different genotypic groups with WDRI polymorphisms rs4604059 (p = 0.005) and rs12498927 (p = 0.005). In addition, significant differences in serum HDL-C levels were detected between different genotypic groups with the CLNK polymorphism rs2041215 (p = 0.001). Polymorphisms of CLNK also affected levels of albumin, triglycerides, and creatinine. This study is the first to investigate and identify positive correlations between WDR1 and CLNK gene polymorphisms in Chinese-Tibetan populations. Our findings provide significant evidence for the effect of genetic polymorphisms on gout-related factors in Chinese-Tibetan populations.

  2. Optical Absorption in Molecular Crystals from Time-Dependent Density Functional Theory

    Science.gov (United States)

    2017-04-23

    Our approach represents a full solid-state calculation, allowing for polarization ef- fects while still capable of capturing inter-molecular dis...AFRL-AFOSR-UK-TR-2017-0030 Optical absorption in molecular crystals from time-dependent density functional theory Leeor Kronik WEIZMANN INSTITUTE OF...from time-dependent density functional theory 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA9550-15-1-0290 5c.  PROGRAM ELEMENT NUMBER 61102F 6. AUTHOR(S

  3. A Fiber-Optic System Generating Pulses of High Spectral Density

    Science.gov (United States)

    Abramov, A. S.; Zolotovskii, I. O.; Korobko, D. A.; Fotiadi, A. A.

    2018-03-01

    A cascade fiber-optic system that generates pulses of high spectral density by using the effect of nonlinear spectral compression is proposed. It is demonstrated that the shape of the pulse envelope substantially influences the degree of compression of its spectrum. In so doing, maximum compression is achieved for parabolic pulses. The cascade system includes an optical fiber exhibiting normal dispersion that decreases along the fiber length, thereby ensuring that the pulse envelope evolves toward a parabolic shape, along with diffraction gratings and a fiber spectral compressor. Based on computer simulation, we determined parameters of cascade elements leading to maximum spectral density of radiation originating from a subpicosecond laser pulse of medium energy.

  4. Multiple-capillary measurement of RBC speed, flux, and density with optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2013-11-01

    As capillaries exhibit heterogeneous and fluctuating dynamics even during baseline, a technique measuring red blood cell (RBC) speed and flux over many capillaries at the same time is needed. Here, we report that optical coherence tomography can capture individual RBC passage simultaneously over many capillaries located at different depths. Further, we demonstrate the ability to quantify RBC speed, flux, and linear density. This technique will provide a means to monitor microvascular flow dynamics over many capillaries at different depths at the same time.

  5. Optical properties of Al nanostructures from time dependent density functional theory

    KAUST Repository

    Mokkath, Junais Habeeb

    2016-04-05

    The optical properties of Al nanostructures are investigated by means of time dependent density functional theory, considering chains of varying length and ladders/stripes of varying aspect ratio. The absorption spectra show redshifting for increasing length and aspect ratio. For the chains the absorption is dominated by HOMO → LUMO transitions, whereas ladders and stripes reveal more complex spectra of plasmonic nature above a specific aspect ratio.

  6. A Novel Approach to the Sensing of Liquid Density Using a Plastic Optical Fibre Cantilever Beam

    Science.gov (United States)

    Kulkarni, Atul; Kim, Youngjin; Kim, Taesung

    2009-01-01

    This article reports for the first time the use of a plastic optical fibre (POF) cantilever beam to measure the density of a liquid. The sensor is based on the Archimedes buoyancy principle. The sensor consists of a POF bonded on the surface of a metal beam in the form of a cantilever configuration, and at the free end of the beam a displacer is…

  7. Highly absorptive curcumin reduces serum atherosclerotic low-density lipoprotein levels in patients with mild COPD

    Directory of Open Access Journals (Sweden)

    Funamoto M

    2016-08-01

    Full Text Available Masafumi Funamoto,1,2 Yoichi Sunagawa,1–3 Yasufumi Katanasaka,1–3 Yusuke Miyazaki,1,2 Atsushi Imaizumi,4 Hideaki Kakeya,5 Hajime Yamakage,2 Noriko Satoh-Asahara,2 Maki Komiyama,2 Hiromichi Wada,2 Koji Hasegawa,2 Tatsuya Morimoto1–3 1Division of Molecular Medicine, School of Pharmaceutical Sciences, University of Shizuoka, Shizuoka, 2Clinical Research Institute, National Hospital Organization Kyoto Medical Center, Kyoto, 3Shizuoka General Hospital, Shizuoka, 4Theravalues Corporation, Kioicho, Tokyo, 5Department of System Chemotherapy and Molecular Sciences, Division of Bioinformatics and Chemical Genomics, Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto, Japan Purpose: COPD is mainly caused by tobacco smoking and is associated with a high frequency of coronary artery disease. There is growing recognition that the inflammation in COPD is not only confined to the lungs but also involves the systemic circulation and can impact nonpulmonary organs, including blood vessels. α1-antitrypsin–low-density lipoprotein (AT-LDL complex is an oxidatively modified LDL that accelerates atherosclerosis. Curcumin, one of the best-investigated natural products, is a powerful antioxidant. However, the effects of curcumin on AT-LDL remain unknown. We hypothesized that Theracurmin®, a highly absorptive curcumin with improved bioavailability using a drug delivery system, ameliorates the inflammatory status in subjects with mild COPD.Patients and methods: This is a randomized, double-blind, parallel-group study. Subjects with stages I–II COPD according to the Japanese Respiratory Society criteria were randomly assigned to receive 90 mg Theracurmin® or placebo twice a day for 24 weeks, and changes in inflammatory parameters were evaluated.Results: There were no differences between the Theracurmin® and placebo groups in terms of age, male/female ratio, or body mass index in 39 evaluable subjects. The percent changes in blood pressure

  8. Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

    Science.gov (United States)

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.

    2016-01-01

    Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505

  9. Technical factors influencing cone packing density estimates in adaptive optics flood illuminated retinal images.

    Directory of Open Access Journals (Sweden)

    Marco Lombardo

    Full Text Available PURPOSE: To investigate the influence of various technical factors on the variation of cone packing density estimates in adaptive optics flood illuminated retinal images. METHODS: Adaptive optics images of the photoreceptor mosaic were obtained in fifteen healthy subjects. The cone density and Voronoi diagrams were assessed in sampling windows of 320×320 µm, 160×160 µm and 64×64 µm at 1.5 degree temporal and superior eccentricity from the preferred locus of fixation (PRL. The technical factors that have been analyzed included the sampling window size, the corrected retinal magnification factor (RMFcorr, the conversion from radial to linear distance from the PRL, the displacement between the PRL and foveal center and the manual checking of cone identification algorithm. Bland-Altman analysis was used to assess the agreement between cone density estimated within the different sampling window conditions. RESULTS: The cone density declined with decreasing sampling area and data between areas of different size showed low agreement. A high agreement was found between sampling areas of the same size when comparing density calculated with or without using individual RMFcorr. The agreement between cone density measured at radial and linear distances from the PRL and between data referred to the PRL or the foveal center was moderate. The percentage of Voronoi tiles with hexagonal packing arrangement was comparable between sampling areas of different size. The boundary effect, presence of any retinal vessels, and the manual selection of cones missed by the automated identification algorithm were identified as the factors influencing variation of cone packing arrangements in Voronoi diagrams. CONCLUSIONS: The sampling window size is the main technical factor that influences variation of cone density. Clear identification of each cone in the image and the use of a large buffer zone are necessary to minimize factors influencing variation of Voronoi

  10. Size-resolved chemical composition, effective density, and optical properties of biomass burning particles

    Science.gov (United States)

    Zhai, Jinghao; Lu, Xiaohui; Li, Ling; Zhang, Qi; Zhang, Ci; Chen, Hong; Yang, Xin; Chen, Jianmin

    2017-06-01

    Biomass burning aerosol has an important impact on the global radiative budget. A better understanding of the correlations between the mixing states of biomass burning particles and their optical properties is the goal of a number of current studies. In this work, the effective density, chemical composition, and optical properties of rice straw burning particles in the size range of 50-400 nm were measured using a suite of online methods. We found that the major components of particles produced by burning rice straw included black carbon (BC), organic carbon (OC), and potassium salts, but the mixing states of particles were strongly size dependent. Particles of 50 nm had the smallest effective density (1.16 g cm-3) due to a relatively large proportion of aggregate BC. The average effective densities of 100-400 nm particles ranged from 1.35 to 1.51 g cm-3 with OC and inorganic salts as dominant components. Both density distribution and single-particle mass spectrometry showed more complex mixing states in larger particles. Upon heating, the separation of the effective density distribution modes confirmed the external mixing state of less-volatile BC or soot and potassium salts. The size-resolved optical properties of biomass burning particles were investigated at two wavelengths (λ = 450 and 530 nm). The single-scattering albedo (SSA) showed the lowest value for 50 nm particles (0.741 ± 0.007 and 0.889 ± 0.006) because of the larger proportion of BC content. Brown carbon played an important role for the SSA of 100-400 nm particles. The Ångström absorption exponent (AAE) values for all particles were above 1.6, indicating the significant presence of brown carbon in all sizes. Concurrent measurements in our work provide a basis for discussing the physicochemical properties of biomass burning aerosol and its effects on the global climate and atmospheric environment.

  11. Increased serum cartilage oligomeric matrix protein levels and decreased patellar bone mineral density in patients with chondromalacia patellae.

    Science.gov (United States)

    Murphy, E; FitzGerald, O; Saxne, T; Bresnihan, B

    2002-11-01

    Chondromalacia patellae is a potentially disabling disorder characterised by features of patellar cartilage degradation. To evaluate markers of cartilage and bone turnover in patients with chondromalacia patellae. 18 patients with chondromalacia patellae were studied. Serum cartilage oligomeric matrix protein (s-COMP) and bone sialoprotein (s-BSP) levels were measured by enzyme linked immunosorbent assay (ELISA) and compared with those of age and sex matched healthy control subjects. Periarticular bone mineral density (BMD) of both knee joints was assessed by dual energy x ray absorptiometry (DXA). s-COMP levels were significantly raised in all patients with chondromalacia patellae compared with healthy control subjects (p=0.0001). s-BSP levels did not differ significantly between the groups (p=0.41). BMD of the patella was significantly reduced in patients with chondromalacia patellae compared with the control subjects (p=0.016). In patients with bilateral chondromalacia patellae, BMD of the patella was lower in the more symptomatic knee joint (p=0.005). Changes in periarticular BMD were localised to the patella and were not present in femoral regions. Neither s-COMP (p=0.18) nor s-BSP (p=0.40) levels correlated with patellar BMD. Increased s-COMP levels, reflecting cartilage degradation, and reduced BMD localised to the patella may represent clinically useful markers in the diagnosis and monitoring of patients with chondromalacia patellae. Measures of cartilage degradation did not correlate with loss of patellar bone density, suggesting dissociated pathophysiological mechanisms.

  12. Optical forces, torques, and force densities calculated at a microscopic level using a self-consistent hydrodynamics method

    Science.gov (United States)

    Ding, Kun; Chan, C. T.

    2018-04-01

    The calculation of optical force density distribution inside a material is challenging at the nanoscale, where quantum and nonlocal effects emerge and macroscopic parameters such as permittivity become ill-defined. We demonstrate that the microscopic optical force density of nanoplasmonic systems can be defined and calculated using the microscopic fields generated using a self-consistent hydrodynamics model that includes quantum, nonlocal, and retardation effects. We demonstrate this technique by calculating the microscopic optical force density distributions and the optical binding force induced by external light on nanoplasmonic dimers. This approach works even in the limit when the nanoparticles are close enough to each other so that electron tunneling occurs, a regime in which classical electromagnetic approach fails completely. We discover that an uneven distribution of optical force density can lead to a light-induced spinning torque acting on individual particles. The hydrodynamics method offers us an accurate and efficient approach to study optomechanical behavior for plasmonic systems at the nanoscale.

  13. Electron density measurement in gas discharge plasmas by optical and acoustic methods

    International Nuclear Information System (INIS)

    Biagioni, A.; Anania, M.P.; Bellaveglia, M.; Chiadroni, E.; Giovenale, D. Di; Pirro, G. Di; Ferrario, M.; Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Cianchi, A.; Filippi, F.; Mostacci, A.; Zigler, A.

    2016-01-01

    Plasma density represents a very important parameter for both laser wakefield and plasma wakefield acceleration, which use a gas-filled capillary plasma source. Several techniques can be used to measure the plasma density within a capillary discharge, which are mainly based on optical diagnostic methods, as for example the well-known spectroscopic method using the Stark broadening effect. In this work, we introduce a preliminary study on an alternative way to detect the plasma density, based on the shock waves produced by gas discharge in a capillary. Firstly, the measurements of the acoustic spectral content relative to the laser-induced plasmas by a solid target allowed us to understand the main properties of the acoustic waves produced during this kind of plasma generation; afterwards, we have extended such acoustic technique to the capillary plasma source in order to calibrate it by comparison with the stark broadening method.

  14. Axial length and cone density as assessed with adaptive optics in myopia

    Directory of Open Access Journals (Sweden)

    Supriya Dabir

    2015-01-01

    Full Text Available Aim: To assess the variations in cone mosaic in myopia and its correlation with axial length (AL. Subjects and Methods: Twenty-five healthy myopic volunteers underwent assessment of photoreceptors using adaptive optics retinal camera at 2° and 3° from the foveal center in four quadrants superior, inferior, temporal and nasal. Data was analyzed using SPSS version 17 (IBM. Multivariable regression analysis was conducted to study the relation between cone density and AL, quadrant around the fovea and eccentricity from the fovea. Results: The mean cone density was significantly lower as the eccentricity increased from 2° from the fovea to 3° (18,560 ± 5455-16,404 ± 4494/mm 2 respectively. There was also a statistically significant difference between four quadrants around the fovea. The correlation of cone density and spacing with AL showed that there was a significant inverse relation of AL with the cone density. Conclusion: In myopic patients with good visual acuity cone density around the fovea depends on the quadrant, distance from the fovea as well as the AL. The strength of the relation of AL with cone density depends on the quadrant and distance.

  15. A novel approach to the sensing of liquid density using a plastic optical fibre cantilever beam

    Science.gov (United States)

    Kulkarni, Atul; Kim, Youngjin; Kim, Taesung

    2009-01-01

    This article reports for the first time the use of a plastic optical fibre (POF) cantilever beam to measure the density of a liquid. The sensor is based on the Archimedes buoyancy principle. The sensor consists of a POF bonded on the surface of a metal beam in the form of a cantilever configuration, and at the free end of the beam a displacer is attached. Due to the apparent loss of the true weight of the displacer there is a deflection in the cantilever beam, which causes macro bending in the POF. The loss of intensity due to macro bending of the POF is a measure of the density of the liquid under test. The variation of weight loss with the density of different liquids showed that the weight loss is proportional to density. This sensor is capable of detecting the weight loss with respect to their densities even for liquids having close values of density like distilled water, tap water, and milk of various brands. The resolution of the sensor is observed to be 1.1 mg cm-3.

  16. Relationship between Body Mass Composition, Bone Mineral Density, Skin Fibrosis and 25(OH Vitamin D Serum Levels in Systemic Sclerosis.

    Directory of Open Access Journals (Sweden)

    Addolorata Corrado

    Full Text Available A reduced bone mineral density (BMD is observed in several rheumatic autoimmune diseases, including Systemic Sclerosis (SSc; nevertheless, data concerning the possible determinants of bone loss in this disease are not fully investigated. The aim of this study is to evaluate the relationship between BMD, body mass composition, skin sclerosis and serum Vitamin D levels in two subsets of SSc patients. 64 post-menopausal SSc patients, classified as limited cutaneous (lcSSc or diffuse cutaneous (dcSSc SSc, were studied. As control, 35 healthy post-menopausal women were recruited. Clinical parameters were evaluated, including the extent of skin involvement. BMD at lumbar spine, hip, femoral neck and body mass composition were determined by dual-energy X-ray absorptiometry. Serum calcium, phosphorus, alkaline phosphatase, urine pyridinium cross-links, intact parathyroid hormone and 25-hydroxyvitamin D (25OHD were measured. BMD at spine, femoral neck and total hip was significantly lower in SSc patients compared to controls. In dcSSc subset, BMD at spine, femoral neck and total hip was significantly lower compared to lcSSc. No differences in both fat and lean mass were found in the three study groups even if patients with dcSSc showed a slightly lower total body mass compared to healthy controls. Total mineral content was significantly reduced in dSSc compared to both healthy subjects and lcSSc group. Hypovitaminosis D was observed both in healthy post-menopausal women and in SSc patients, but 25OHD levels were significantly lower in dcSSc compared to lcSSc and inversely correlated with the extent of skin thickness. These results support the hypothesis that the extent of skin involvement in SSc patients could be an important factor in determining low circulating levels of 25OHD, which in turn could play a significant role in the reduction of BMD and total mineral content.

  17. Optical rotation calculated with time-dependent density functional theory: the OR45 benchmark.

    Science.gov (United States)

    Srebro, Monika; Govind, Niranjan; de Jong, Wibe A; Autschbach, Jochen

    2011-10-13

    Time-dependent density functional theory (TDDFT) computations are performed for 42 organic molecules and three transition metal complexes, with experimental molar optical rotations ranging from 2 to 2 × 10(4) deg cm(2) dmol(-1). The performances of the global hybrid functionals B3LYP, PBE0, and BHLYP, and of the range-separated functionals CAM-B3LYP and LC-PBE0 (the latter being fully long-range corrected), are investigated. The performance of different basis sets is studied. When compared to liquid-phase experimental data, the range-separated functionals do, on average, not perform better than B3LYP and PBE0. Median relative deviations between calculations and experiment range from 25 to 29%. A basis set recently proposed for optical rotation calculations (LPol-ds) on average does not give improved results compared to aug-cc-pVDZ in TDDFT calculations with B3LYP. Individual cases are discussed in some detail, among them norbornenone for which the LC-PBE0 functional produced an optical rotation that is close to available data from coupled-cluster calculations, but significantly smaller in magnitude than the liquid-phase experimental value. Range-separated functionals and BHLYP perform well for helicenes and helicene derivatives. Metal complexes pose a challenge to first-principles calculations of optical rotation.

  18. Statistical measurement of power spectrum density of large aperture optical component

    International Nuclear Information System (INIS)

    Xu Jiancheng; Xu Qiao; Chai Liqun

    2010-01-01

    According to the requirement of ICF, a method based on statistical theory has been proposed to measure the power spectrum density (PSD) of large aperture optical components. The method breaks the large-aperture wavefront into small regions, and obtains the PSD of the large-aperture wavefront by weighted averaging of the PSDs of the regions, where the weight factor is each region's area. Simulation and experiment demonstrate the effectiveness of the proposed method. They also show that, the obtained PSDs of the large-aperture wavefront by statistical method and sub-aperture stitching method fit well, when the number of small regions is no less than 8 x 8. The statistical method is not sensitive to translation stage's errors and environment instabilities, thus it is appropriate for PSD measurement during the process of optical fabrication. (authors)

  19. Additional consumption of one egg per day increases serum lutein plus zeaxanthin concentration and lowers oxidized low-density lipoprotein in moderately hypercholesterolemic males.

    Science.gov (United States)

    Kishimoto, Yoshimi; Taguchi, Chie; Saita, Emi; Suzuki-Sugihara, Norie; Nishiyama, Hiroshi; Wang, Wei; Masuda, Yasunobu; Kondo, Kazuo

    2017-09-01

    The egg is a nutrient-dense food and contains antioxidative carotenoids, lutein and zeaxanthin, but its impact on serum cholesterol levels has been a matter of concern, especially for individuals who have high serum cholesterol levels. We conducted this study to determine whether and how the daily additional consumption of one egg affects serum lipid profiles and parameters of LDL oxidation in moderately hypercholesterolemic males. Nineteen male Japanese adults (total cholesterol [TC]>5.2mmol/L) participated, consuming one soft boiled egg per day for 4weeks in addition to their habitual diet. Despite the significant increase in their intake of dietary cholesterol during the intervention period, the subjects' serum concentrations of TC and low-density lipoprotein cholesterol (LDL-C) did not increase. Their serum malondialdehyde modified low-density lipoprotein (MDA-LDL) concentrations were significantly decreased and their LDL oxidation lag times, reflecting the resistance of free-radical-induced LDL lipid peroxidation (ex vivo), was prolonged after 2 and 4weeks. At weeks 2 and 4, the subjects' serum lutein+zeaxanthin concentrations were significantly higher than their baseline values and showed both an inverse relation with MDA-LDL and a positive relationship with the LDL oxidation lag time. These data showed that in moderately hypercholesterolemic males, the additional consumption of one egg per day for 4weeks did not have adverse effects on serum TC or LDL-C, and it might reduce the susceptibility of LDL to oxidation through an increase in the serum lutein and zeaxanthin concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements

    International Nuclear Information System (INIS)

    Nonato de Oliveira, Lucas; Sampaio, Francisco Glaildo Almeida; Moreira, Marcos Vasques; Almeida, Adelaide de

    2014-01-01

    In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe 3+ in Fricke Xylenol gel (FXG) are necessary for determining the spatial distribution of the absorbed dose from measurements of the optical density. Five sets of FXG dosimeters, kept at different constant temperatures, were exposed to collimated 6 MV photons. The optical density profile, proportional to the Fe 3+ concentration, at the boundary between irradiated and non-irradiated parts of each dosimeter was measured periodically over a period of 60 h. By comparing the experimental data with a function that accounts for the unobserved initial concentration profile of Fe 3+ in the FXG, we obtained diffusion coefficients 0.30±0.05, 0.40±0.05, 0.50±0.05, 0.60±0.05 and 0.80±0.05 mm 2 /h for the temperatures 283.0±0.5, 286.0±0.5, 289.0±0.5, 292.0±0.5, and 296.0±0.5 K, respectively. The activation energy of Fe 3+ diffusion in the gel, 0.54±0.06 eV, was determined from the temperature dependence of the diffusion coefficients. - Highlights: • A new analytical method to determine diffusion coefficients of ions in gels is proposed. • The method is applied for measurements of the diffusion coefficients of Fe 3+ ions in a Fricke gel dosimeter. • Activation energy of the Fe 3+ ions in the gel was found to be 0.54 ±0.06 eV

  1. The Quantitative Measurements of Vascular Density and Flow Area of Optic Nerve Head Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Bazvand, Fatemeh; Mirshahi, Reza; Fadakar, Kaveh; Faghihi, Houshangh; Sabour, Siamak; Ghassemi, Fariba

    2017-08-01

    The purpose of this study was to evaluate the vascular density (VD) and the flow area on optic nerve head (ONH) and peripapillary area, and the impact of age and sex using optical coherence tomography angiography (OCTA) in healthy human subjects. Both eyes of each volunteer were scanned by an RTVue XR Avanti; Optovue with OCTA using the split-spectrum amplitude-decorrelation angiography algorithm technique. Masked graders evaluated enface angiodisc OCTA data. The flow area of ONH and the VD were automatically calculated. A total of 79 eyes of patients with a mean age of 37.03±11.27 were examined. The total ONH (papillary and peripapillary) area VD was 56.03%±4.55%. The flow area of the ONH was 1.74±0.10 mm/1.34 mm. The temporal and inferotemporal peripapillary VD was different between male and female patients. Increasing age causes some changes in the flow area of the ONH and the papillary VD from the third to the fourth decade (analysis of variance test; P<0.05). A normal quantitative database of the flow area and VD of the papillary and peripapillary area, obtained by RTVue XR with OCT angiography technique, is presented here.

  2. Spatially resolvable optical emission spectrometer for analyzing density uniformity of semiconductor process plasma

    International Nuclear Information System (INIS)

    Oh, Changhoon; Ryoo, Hoonchul; Lee, Hyungwoo; Hahn, Jae W.; Kim, Se-Yeon; Yi, Hun-Jung

    2010-01-01

    We proposed a spatially resolved optical emission spectrometer (SROES) for analyzing the uniformity of plasma density for semiconductor processes. To enhance the spatial resolution of the SROES, we constructed a SROES system using a series of lenses, apertures, and pinholes. We calculated the spatial resolution of the SROES for the variation of pinhole size, and our calculated results were in good agreement with the measured spatial variation of the constructed SROES. The performance of the SROES was also verified by detecting the correlation between the distribution of a fluorine radical in inductively coupled plasma etch process and the etch rate of a SiO 2 film on a silicon wafer.

  3. Effect of Current Density on Thermal and Optical Properties of p-Type Porous Silicon

    International Nuclear Information System (INIS)

    Kasra Behzad; Wan Mahmood Mat Yunus; Zainal Abidin Talib; Azmi Zakaria; Afarin Bahrami

    2011-01-01

    The different parameters of the porous silicon (PSi) can be tuned by changing some parameters in preparation process. We have chosen the anodization as formation method, so the related parameters should be changed. In this study the porous silicon (PSi) layers were formed on p-type Si wafer. The samples were anodized electrically in a fixed etching time under some different current densities. The structural and optical properties of porous silicon (PSi) on silicon (Si) substrates were investigated using photoluminescence (PL) and Photoacoustic Spectroscopy (PAS). (author)

  4. Platelet activating factor-acylhydrolase (PAF-ase) activity is higher in serum of men than women and is related to levels of low density lipoprotein (LDL)

    International Nuclear Information System (INIS)

    Farr, R.S.; Howell, S.E.; Wardlow, M.L.

    1986-01-01

    PAF-ase is a specific serum enzyme that inactivates PAF by hydrolyzing acetate from the sn-2 position of the glycerol backbone. A reproducible PAF-ase activity assay was developed. A unit is based on the amount of serum required to release 3.61 +/- 0.042 pm 3 H-acetate from 10 pm 3 H-labeled PAF after incubation for 1 hr at 37 0 C. Assays on two single reference serums repeated 7 days were 0.63 +/- 0.013 U and 1.33 +/- 0.031 U. Serum from 20 normal men and 20 normal premenopausal women had significantly different (p = <0.001) levels of 1.32 +/- 0.072 U and 0.97 +/- 0.051 U respectively. They previously reported that PAF-ase is associated with B-lipoprotein. Therefore, total cholesterol (TC), LDL and high density lipoproteins (HDL) were determined on these 40 serums. Regression analysis revealed PAF-ase units were correlated with LDL (r = 0.740; p = < 0.001) and, parenthetically, with the TC (r = 0.620; p = < 0.001) but not with HDL. These correlations were similar for men and women. Thus, serum PAF-ase was partially controlled by serum LDL levels and the higher PAF-ase levels in serum from men were due in part to higher (p = < 0.01) LDL levels in men (147.6 +/- 6.9 mg/dl) as contrasted to women (119.0 +/- 7.6 mg/dl). PAF is a potent inflammatory, bronchoconstrictive and hypotensive agent. These data indicate that sex and serum LDL levels of subjects must be considered during future studies of the role of PAF vs PAF-ase in different disease states

  5. Diffuse optical tomography with structured-light patterns to quantify breast density

    Science.gov (United States)

    Kwong, Jessica; Nouizi, Farouk; Cho, Jaedu; Zheng, Jie; Li, Yifan; Chen, Jeon-hor; Su, Min-Ying; Gulsen, Gultekin

    2016-02-01

    Breast density is an independent risk factor for breast cancer, where women with denser breasts are more likely to develop cancer. By identifying women at higher risk, healthcare providers can suggest screening at a younger age to effectively diagnose and treat breast cancer in its earlier stages. Clinical risk assessment models currently do not incorporate breast density, despite its strong correlation with breast cancer. Current methods to measure breast density rely on mammography and MRI, both of which may be difficult to use as a routine risk assessment tool. We propose to use diffuse optical tomography with structured-light to measure the dense, fibroglandular (FGT) tissue volume, which has a different chromophore signature than the surrounding adipose tissue. To test the ability of this technique, we performed simulations by creating numerical breast phantoms from segmented breast MR images. We looked at two different cases, one with a centralized FGT distribution and one with a dispersed distribution. As expected, the water and lipid volumes segmented at half-maximum were overestimated for the dispersed case. However, it was noticed that the recovered water and lipid concentrations were lower and higher, respectively, than the centralized case. This information may provide insight into the morphological distribution of the FGT and can be a correction in estimating the breast density.

  6. Association of age and macular pigment optical density using dual-wavelength autofluorescence imaging

    Directory of Open Access Journals (Sweden)

    Lima VC

    2013-04-01

    Full Text Available Verônica Castro Lima,1,2 Richard B Rosen,1,3 Tiago Santos Prata,2 Syril Dorairaj,4 Leigh Spielberg,1 Mauricio Maia,2 Juliana M Sallum21Retina Service, Department of Ophthalmology, The New York Eye and Ear Infirmary, New York, NY, 2Department of Ophthalmology, Federal University of São Paulo, São Paulo, Brazil; 3New York Medical College, New York, NY, 4Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USABackground: Several lines of evidence suggest that macular pigment may play a protective role against age-related macular degeneration, but the influence of age on macular pigment density levels remains unclear. This study was designed to investigate the relationship between age and the normal distribution of macular pigment optical density (MPOD values surrounding the fovea.Methods: Consecutive healthy subjects with no evidence of ocular disease were enrolled in this study. After inclusion, MPOD values were measured at specific eccentricities (0.5, 1, and 2 degrees from the foveal center using a dual-wavelength autofluorescence method employing a modified confocal scanning laser ophthalmoscope. Whenever both eyes were eligible, one was randomly selected for analysis. The correlation between age and MPOD values was investigated using regression analysis.Results: Thirty subjects (30 eyes were included (mean age 48.6 ± 16.4 [range 23–77] years. Significant differences were found between MPOD values measured at 0.5, 1, and 2 degrees from the center of the fovea (0.49 ± 0.12 density units, 0.37 ± 0.11 density units, and 0.13 ± 0.05 density units, respectively, P < 0.05. Significant correlations between age and MPOD values at 0.5 and 1 degree were found (P ≤ 0.02. Values measured at 2 degrees did not correlate significantly with age (P = 0.06.Conclusion: In healthy subjects, MPOD values were highest near the foveal center. These values appeared to increase during adulthood (peak at 45–50 years, followed by a gradual reduction

  7. Interaction of estradiol and high density lipoproteins on proliferation of the human breast cancer cell line MCF-7 adapted to grow in serum free conditions

    International Nuclear Information System (INIS)

    Jozan, S.; Faye, J.C.; Tournier, J.F.; Tauber, J.P.; David, J.F.; Bayard, F.

    1985-01-01

    The responsiveness of the human mammary carcinoma cell line MCF-7 to estradiol and tamoxifen treatment has been studied in different culture conditions. Cells from exponentially growing cultures were compared with cells in their initial cycles after replating from confluent cultures (''confluent-log'' cells). It has been observed that estradiol stimulation of tritiated thymidine incorporation decreases with cell density and that ''confluent-log'' cells are estrogen unresponsive for a period of four cell cycles in serum-free medium conditions. On the other hand, growth of cells replated from exponentially growing, as well as from confluent cultures, can be inhibited by tamoxifen or a combined treatment with tamoxifen and the progestin levonorgestrel. This growth inhibitory effect can be rescued by estradiol when cells are replated from exponentially growing cultures. The growth inhibitory effect cannot be rescued by estradiol alone (10(-10) to 10(-8) M) when cells are replated from confluent cultures. In this condition, the addition of steroid depleted serum is necessary to reverse the state of estradiol unresponsiveness. Serum can be replaced by high density lipoproteins but not by low density lipoproteins or lipoprotein deficient serum. The present data show that estradiol and HDL interact in the control of MCF-7 cell proliferation

  8. Hydrostatic pressure effects on the state density and optical transitions in quantum dots

    International Nuclear Information System (INIS)

    Galindez-Ramirez, G; Perez-Merchancano, S T; Paredes Gutierrez, H; Gonzalez, J D

    2010-01-01

    Using the effective mass approximation and variational method we have computed the effects of hydrostatic pressure on the absorption and photoluminescence spectra in spherical quantum dot GaAs-(Ga, Al) As, considering a finite confinement potential of this particular work we show the optical transitions in quantum of various sizes in the presence of hydrogenic impurities and hydrostatic pressure effects. Our first result describes the spectrum of optical absorption of 500 A QD for different values of hydrostatic pressure P = 0, 20 and 40 Kbar. The absorption peaks are sensitive to the displacement of the impurity center to the edge of the quantum dot and even more when the hydrostatic pressure changes in both cases showing that to the extent that these two effects are stronger quantum dots respond more efficiently. Also this result can be seen in the study of the photoluminescence spectrum as in the case of acceptor impurities consider them more efficiently capture carriers or electrons that pass from the conduction band to the valence band. Density states with randomly distributed impurity show that the additional peaks in the curves of the density of impurity states appear due to the presence of the additional hydrostatic pressure effects.

  9. Recording of radiation-induced optical density changes in doped agarose gels with a CCD camera

    International Nuclear Information System (INIS)

    Tarte, B.J.; Jardine, P.A.; Van Doorn, T.

    1996-01-01

    Full text: Spatially resolved dose measurement with iron-doped agarose gels is continuing to be investigated for applications in radiotherapy dosimetry. It has previously been proposed to use optical methods, rather than MRI, for dose measurement with such gels and this has been investigated using a spectrophotometer (Appleby A and Leghrouz A, Med Phys, 18:309-312, 1991). We have previously studied the use of a pencil beam laser for such optical density measurement of gels and are currently investigating charge-coupled devices (CCD) camera imaging for the same purpose but with the advantages of higher data acquisition rates and potentially greater spatial resolution. The gels used in these studies were poured, irradiated and optically analysed in Perspex casts providing gel sections 1 cm thick and up to 20 cm x 30 cm in dimension. The gels were also infused with a metal indicator dye (xylenol orange) to render the radiation induced oxidation of the iron in the gel sensitive to optical radiation, specifically in the green spectral region. Data acquisition with the CCD camera involved illumination of the irradiated gel section with a diffuse white light source, with the light from the plane of the gel section focussed to the CCD array with a manual zoom lens. The light was also filtered with a green colour glass filter to maximise the contrast between unirradiated and irradiated gels. The CCD camera (EG and G Reticon MC4013) featured a 1024 x 1024 pixel array and was interfaced to a PC via a frame grabber acquisition board with 8 bit resolution. The performance of the gel dosimeter was appraised in mapping of physical and dynamic wedged 6 MV X-ray fields. The results from the CCD camera detection system were compared with both ionisation chamber data and laser based optical density measurements of the gels. Cross beam profiles were extracted from each measurement system at a particular depth (eg. 2.3 cm for the physical wedge field) for direct comparison. A

  10. Optical Depth Estimates and Effective Critical Densities of Dense Gas Tracers in the Inner Parts of Nearby Galaxy Discs

    OpenAIRE

    Jimenez-Donaire, M. J.; Bigiel, F.; Leroy, A. K.; Cormier, D.; Gallagher, M.; Usero, A.; Bolatto, A.; Colombo, D.; Garcia-Burillo, S.; Hughes, A.; Kramer, C.; Krumholz, M. R.; Meier, D. S.; Murphy, E.; Pety, J.

    2016-01-01

    High critical density molecular lines like HCN(1-0) or HCO+(1-0) represent our best tool to study currently star-forming, dense molecular gas at extragalactic distances. The optical depth of these lines is a key ingredient to estimate the effective density required to excite emission. However, constraints on this quantity are even scarcer in the literature than measurements of the high density tracers themselves. Here, we combine new observations of HCN, HCO+ and HNC(1-0) and their optically ...

  11. Association of age and macular pigment optical density using dual-wavelength autofluorescence imaging.

    Science.gov (United States)

    Lima, Verônica Castro; Rosen, Richard B; Prata, Tiago Santos; Dorairaj, Syril; Spielberg, Leigh; Maia, Mauricio; Sallum, Juliana M

    2013-01-01

    Several lines of evidence suggest that macular pigment may play a protective role against age-related macular degeneration, but the influence of age on macular pigment density levels remains unclear. This study was designed to investigate the relationship between age and the normal distribution of macular pigment optical density (MPOD) values surrounding the fovea. Consecutive healthy subjects with no evidence of ocular disease were enrolled in this study. After inclusion, MPOD values were measured at specific eccentricities (0.5, 1, and 2 degrees) from the foveal center using a dual-wavelength autofluorescence method employing a modified confocal scanning laser ophthalmoscope. Whenever both eyes were eligible, one was randomly selected for analysis. The correlation between age and MPOD values was investigated using regression analysis. Thirty subjects (30 eyes) were included (mean age 48.6 ± 16.4 [range 23-77] years). Significant differences were found between MPOD values measured at 0.5, 1, and 2 degrees from the center of the fovea (0.49 ± 0.12 density units, 0.37 ± 0.11 density units, and 0.13 ± 0.05 density units, respectively, P < 0.05). Significant correlations between age and MPOD values at 0.5 and 1 degree were found (P ≤ 0.02). Values measured at 2 degrees did not correlate significantly with age (P = 0.06). In healthy subjects, MPOD values were highest near the foveal center. These values appeared to increase during adulthood (peak at 45-50 years), followed by a gradual reduction after 60 years of age.

  12. Persistent tumor-induced osteomalacia confirmed by elevated postoperative levels of serum fibroblast growth factor-23 and 5-year follow-up of bone density changes.

    Science.gov (United States)

    Zimering, Mark B; Caldarella, Felice A; White, Kenneth E; Econs, Michael J

    2005-01-01

    To describe a case of persistent tumor-induced osteomalacia, determine whether serum fibroblast growth factor-23 (FGF-23) levels postoperatively indicate incomplete tumor resection, and report lumbar spine and forearm bone mineral density (BMD) changes during 5 years of follow-up. We present clinical, radiologic, histologic, and bone densitometry data as well as serum FGF-23 levels (determined with use of a novel C-terminal enzyme-linked immunosorbent assay) from the study patient and discuss these findings in the context of previous literature. A 52-year-old man, who presented with muscle weakness and multiple fractures, was found to have low values for serum phosphorus, serum 1,25-dihydroxyvitamin D, and maximal tubular reabsorption of phosphate per glomerular filtration rate, a high level of serum alkaline phosphatase, and a normal serum concentration of parathyroid hormone, characteristic of tumor-induced osteomalacia. Magnetic resonance imaging to evaluate an abnormality of the left foot revealed a soft tissue mass, biopsy of which confirmed the presence of a benign, phosphaturic, mesenchymal tumor. The baseline serum FGF-23 level (2,050 RU/mL) was more than 17 times the upper limit of normal for adults (23 to 118 RU/mL) and decreased substantially within 1 day after partial resection of the tumor but remained above normal postoperatively. BMD changes indicated rapid substantial recovery of vertebral BMD but ongoing loss of forearm bone density. The serum FGF-23 level is high in a substantial proportion of patients with tumor-induced osteomalacia. The postoperative above normal levels of serum FGF-23 correlated with known persistence of tumor in our study patient. In a patient with normal renal function, such as our study patient, levels of serum FGF-23 studied with use of the C-terminal enzyme-linked immunosorbent assay reached their nadir within 24 hours postoperatively. This result suggests that this assay can provide clinicians with rapid prognostic

  13. Density functional approach to many-body effects in the optical response of atoms

    International Nuclear Information System (INIS)

    Zangwill, A.

    1981-01-01

    The purpose of this work is to present a new method for calculating the optical response of finite electronic system which is accurate, computationally simple, and lends itself to a ready physical interpretation of the results. This work is concerned with the so-called many-body effects which render an independent particle calculation inappropriate for comparison with experimental photoabsorption and photoemission cross sections. Polarization effects are included which describe the response of the system to an external probe and self-energy effects, which describe the dynamics and decay of a single particle state. This work, which essentially reintroduces the residual Coulomb interactions among the electrons, is confined to atoms. The method is a time-dependent local density approximation (TDLDA) and represents a natural generalization of the usual local density approximation to the ground state properties of a many electron system. Using standard first-order time-dependent perturbation theory, a self-consistent mean field theory is derived for an effective field which replaces the external field in the dipole matrix elements of the Golden Rule for photoabsorption. This effective field includes a contribution from an induced classical Coulomb field as well as an induced exchange-correlation field. This work successfully demonstrates the applicability of time-dependent generalization of the local density approximation to the practical calculation of the photo-response of atoms. For the rare gases, barium, cerium and copper are obtained cross sections in quantitative agreement with recent experiments

  14. Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading

    Directory of Open Access Journals (Sweden)

    You Na Kim

    2016-01-01

    Full Text Available Purpose. To quantify whole lens and nuclear lens densities using anterior-segment optical coherence tomography (OCT with a liquid optics interface and evaluate their correlation with Lens Opacities Classification System III (LOCS III lens grading and corrected distance visual acuity (BCVA. Methods. OCT images of the whole lens and lens nucleus of eyes with age-related nuclear cataract were analyzed using ImageJ software. The lens grade and nuclear density were represented in pixel intensity units (PIU and correlations between PIU, BCVA, and LOCS III were assessed. Results. Forty-seven eyes were analyzed. The mean whole lens and lens nuclear densities were 26.99 ± 5.23 and 19.43 ± 6.15 PIU, respectively. A positive linear correlation was observed between lens opacities (R2 = 0.187, p<0.01 and nuclear density (R2 = 0.316, p<0.01 obtained from OCT images and LOCS III. Preoperative BCVA and LOCS III were also positively correlated (R2 = 0.454, p<0.01. Conclusions. Whole lens and lens nuclear densities obtained from OCT correlated with LOCS III. Nuclear density showed a higher positive correlation with LOCS III than whole lens density. OCT with a liquid optics interface is a potential quantitative method for lens grading and can aid in monitoring and managing age-related cataracts.

  15. Vitamin A Intake, Serum Vitamin D and Bone Mineral Density: Analysis of the Korea National Health and Nutrition Examination Survey (KNHANES, 2008–2011

    Directory of Open Access Journals (Sweden)

    Nam-Seok Joo

    2015-03-01

    Full Text Available The association of high vitamin A intake and low bone mineral density (BMD is still controversial. To determine the association of dietary vitamin A intake and serum 25-hydroxyvitamin D (25(OHD concentration with BMD, a total of 6481 subjects (2907 men and 3574 women aged ≥50 years from the Korean National Health and Nutrition Examination Survey (2008–2011 were divided into groups according to dietary vitamin A intake (tertiles and serum 25(OHD (<50, 50–75, >75 nmol/L, and evaluated for BMD after adjusting for relevant variables. Mean dietary vitamin A intakes were 737 and 600 μg RE (Retinol Equivalents in men and women, respectively. Total hip and femoral neck BMD in men and lumbar spine BMD in women were both positively correlated with dietary vitamin A intake in subjects with serum 25(OHD >75 nmol/L. Among men with serum 25(OHD <50 nmol/L, both the top (mean 1353 μg RE and bottom (mean 218 μg RE tertiles of dietary vitamin A intake had lower BMD than the middle group (mean 577 μg RE. In this population, BMD was the highest among men and women with serum 25(OHD = 50–75 nmol/L and that there were no differences in BMD by vitamin A intake in these vitamin D adequate groups. This cross-sectional study indicates that vitamin A intake does not affect bone mineral density as long as the serum 25(OHD concentration is maintained in the moderate level of 50–75 nmol/L.

  16. Vitamin A intake, serum vitamin D and bone mineral density: analysis of the Korea National Health and Nutrition Examination Survey (KNHANES, 2008-2011).

    Science.gov (United States)

    Joo, Nam-Seok; Yang, Sung-Won; Song, Byeng Chun; Yeum, Kyung-Jin

    2015-03-10

    The association of high vitamin A intake and low bone mineral density (BMD) is still controversial. To determine the association of dietary vitamin A intake and serum 25-hydroxyvitamin D (25(OH)D) concentration with BMD, a total of 6481 subjects (2907 men and 3574 women) aged ≥50 years from the Korean National Health and Nutrition Examination Survey (2008-2011) were divided into groups according to dietary vitamin A intake (tertiles) and serum 25(OH)D (75 nmol/L), and evaluated for BMD after adjusting for relevant variables. Mean dietary vitamin A intakes were 737 and 600 μg RE (Retinol Equivalents) in men and women, respectively. Total hip and femoral neck BMD in men and lumbar spine BMD in women were both positively correlated with dietary vitamin A intake in subjects with serum 25(OH)D >75 nmol/L. Among men with serum 25(OH)D L, both the top (mean 1353 μg RE) and bottom (mean 218 μg RE) tertiles of dietary vitamin A intake had lower BMD than the middle group (mean 577 μg RE). In this population, BMD was the highest among men and women with serum 25(OH)D = 50-75 nmol/L and that there were no differences in BMD by vitamin A intake in these vitamin D adequate groups. This cross-sectional study indicates that vitamin A intake does not affect bone mineral density as long as the serum 25(OH)D concentration is maintained in the moderate level of 50-75 nmol/L.

  17. Inelastic collisions and density-dependent excitation suppression in a 87Sr optical lattice clock

    International Nuclear Information System (INIS)

    Bishof, M.; Martin, M. J.; Swallows, M. D.; Benko, C.; Lin, Y.; Quemener, G.; Rey, A. M.; Ye, J.

    2011-01-01

    We observe two-body loss of 3 P 0 87 Sr atoms trapped in a one-dimensional optical lattice. We measure loss rate coefficients for atomic samples between 1 and 6 μK that are prepared either in a single nuclear-spin sublevel or with equal populations in two sublevels. The measured temperature and nuclear-spin preparation dependence of rate coefficients agree well with calculations and reveal that rate coefficients for distinguishable atoms are only slightly enhanced over those of indistinguishable atoms. We further observe a suppression of excitation and losses during interrogation of the 1 S 0 - 3 P 0 transition as density increases and Rabi frequency decreases, which suggests the presence of strong interactions in our dynamically driven many-body system.

  18. Electronic and Optical Properties of Sodium Niobate: A Density Functional Theory Study

    Directory of Open Access Journals (Sweden)

    Daniel Fritsch

    2018-01-01

    Full Text Available In recent years, much effort has been devoted to replace the most commonly used piezoelectric ceramic lead zirconate titanate Pb[ZrxTi1−x]O3 (PZT with a suitable lead-free alternative for memory or piezoelectric applications. One possible alternative to PZT is sodium niobate as it exhibits electrical and mechanical properties that make it an interesting material for technological applications. The high-temperature simple cubic perovskite structure undergoes a series of structural phase transitions with decreasing temperature. However, particularly the phases at room temperature and below are not yet fully characterised and understood. Here, we perform density functional theory calculations for the possible phases at room temperature and below and report on the structural, electronic, and optical properties of the different phases in comparison to experimental findings.

  19. Lipoprotein distribution and serum concentrations of 7α-hydroxy-4-cholesten-3-one and bile acids: effects of monogenic disturbances in high-density lipoprotein metabolism

    DEFF Research Database (Denmark)

    Steiner, Carine; Holleboom, Adriaan G; Karuna, Ratna

    2012-01-01

    BA (bile acid) formation is considered an important final step in RCT (reverse cholesterol transport). HDL (high-density lipoprotein) has been reported to transport BAs. We therefore investigated the effects of monogenic disturbances in human HDL metabolism on serum concentrations and lipoprotein...... concentrations of conjugated and secondary BAs differed between heterozygous carriers of SCARB1 (scavenger receptor class B1) mutations and unaffected individuals (P...

  20. Correlations between internal and external ocular factors and macular pigment optical density.

    Science.gov (United States)

    Tudosescu, Ruxandra; Alexandrescu, Cristina Mihaela; Istrate, Sânziana Luminiţa; Vrapciu, Alexandra Diana; Ciuluvică, Radu Constantin; Voinea, Liliana

    2018-01-01

    To assess the relationship between the macular pigment optical density and blue-light issued by computers, glare sensibility, with iris color, age, sex, or refractive errors. 83 patients (166 eyes) were enrolled in a prospective observational study. They were divided into 2 groups: group 1 (study group) - computer using patients (time spent in front of the computer for minimum 8 hours per day, 5 days per week, 2 years) - 43 patients and group 2 (control group) - 40 patients. The following investigations were conducted in all the selected cases: visual acuity, refraction, biomicroscopy, measurement of the MPOD, glare sensitivity, assessment of eye color. 51.81% of the patients were included in group 1, while the rest, 48.19%, were in group 2. Thus, the MPOD had a mean value of (+/ -SD) 0.42+/ -0.13 (t = -1.08, p = 0.28) in group 1, and 0.44+/ -0.16 on the LE. The results showed a MPOD mean value of 0.51+/ - 0.16 in group 2 and 0.51+/ -0 .16. (t = 0.49, p = 0 .62) on the LE. 55.77% of the patients with light colored iris and 56.14% of those with dark iris had a low MPOD. The data from our study failed to illustrate a significant correlation between MPOD and blue-light issued by computers. Furthermore, a statistic significant relationship regarding iris color, refractive errors, glare, and MPOD was not observed. L = lutein, Z = zeaxanthin, MZ = meso-zeaxanthin, AMD = age related macular degeneration, MPOD = macular pigment optical density, MP = macular pigment, HFP = Heterochromatic Flicker Photometry, RE = right eye, LE = left eye.

  1. The Effects of Bone Mineral Density and Level of Serum Vitamin-D on Pain and Quality of Life in Fibromialgia Patients - Original Investigation

    Directory of Open Access Journals (Sweden)

    Ayşegül Küçükali Türkyılmaz

    2010-12-01

    Full Text Available Aim: The purpose of this study is to determine bone mineral density (BMD and the levels of serum 25-OH-vitamin D3 in premenopausal Fibromyalgia Syndrome (FMS patients, and to examine the effect of them to the pain and quality of life in premenopausal FMS patients. Material and Methods: Premenouposal 30 patients with fibromyalgia and 30 healthy controls included the study. The demographic characteristic, serum values, vitamin D levels, bone mineral density measurements, Visual Analog Scala (VAS, Beck Depression Inventory (BDI, Short Form- 36 (SF-36 and Fibromyalgia Impact Questionery Form (FIQ were determined. Patient and control group were compared in terms of these parameters. Results: There was no significant difference of Vitamin D levels and bone mineral density between case and controls. There was no significant difference between the groups with low and high vitamin D levels in terms of VAS, FIQ, BDI in SF-36 in FMS patients. There was no significant change with regard to VAS, FIQ, BDI, and SF36 between FMS patients with high or low BMD. Conclusion: There is no difference of vitamin D levels and bone mineral density between FMS patients and control group, vitamin D levels and bone mineral density have no effect on pain and quality of life in premenopausal patients with FMS. (From the World of Osteoporosis 2010;16:53-7

  2. Preliminary analysis of modified low density lipoproteins in the serum of healthy and obese dogs and cats

    Directory of Open Access Journals (Sweden)

    Nobuko eMori

    2015-09-01

    Full Text Available Oxidized low-density lipoprotein (LDL is thought to play an important role in the inflammatory response associated with human obesity. The purpose of this preliminary study was to determine oxidized LDL concentrations in healthy dogs and cats, and to evaluate whether obesity affects oxidized LDL concentration, using 39 cats and 19 dogs that had visited 2 different veterinary clinics in Japan. We hypothesized that oxidized LDL concentrations measured against body condition score (BCS may have a potential value in evaluating the qualities of accumulated or circulating lipids in obese dogs and cats that do not show signs of metabolic diseases. The mean oxidized LDL value in BCS3 dogs (2.4 ± 0.9 μg/dl was very similar to that of BCS5 dogs (2.2 ± 0.3 μg/dl. The mean oxidized LDL value of BCS4 dogs was 7.2 ± 10.3 μg/dl and the highest among three groups. BCS4 dogs included two dogs whose oxidized LDL values were higher than the mean oxidized LDL value of healthy humans (11.2 ± 0.3 μg/dl. On the other hand, the mean oxidized LDL value of BCS3 cats was 2.5 ± 0.9 μg/dl, and those of BCS4 and 5 cats were higher than that of BCS3, but there was no significant difference. The BCS4 cat group included one cat with a higher oxidized LDL value, and the BCS5 group also included two cats with oxidized LDL values higher than the mean oxidized LDL value of healthy humans. Interestingly, the oxidized LDL values in 2 obese dogs and 3 obese cats were indeed higher than the mean oxidized LDL value of humans with coronary artery disease (20.1 ± 1.1 μg/dl. In conclusion, this preliminary study showed reference ranges of oxidized dogs and cats against BCS. Obesity alone does not appear to have any direct effect on serum oxidized LDL values in healthy dogs and cats.

  3. Enhancing DNA binding rate using optical trapping of high-density gold nanodisks

    International Nuclear Information System (INIS)

    Lin, En-Hung; Pan, Ming-Yang; Lee, Ming-Chang; Wei, Pei-Kuen

    2014-01-01

    We present the dynamic study of optical trapping of fluorescent molecules using high-density gold nanodisk arrays. The gold nanodisks were fabricated by electron beam lithography with a diameter of 500 nm and a period of 1 μm. Dark-field illumination showed ∼15 times enhancement of fluorescence near edges of nanodisks. Such enhanced near-field generated an optical trapping force of ∼10 fN under 3.58 × 10 3 W/m 2 illumination intensity as calculated from the Brownian motions of 590 nm polystyrene beads. Kinetic observation of thiolated DNA modified with Cy5 dye showed different binding rates of DNA under different illumination intensity. The binding rate increased from 2.14 × 10 3 s −1 (I = 0.7 × 10 3 W/m 2 ) to 1.15 × 10 5 s −1 (I = 3.58 × 10 3 W/m 2 ). Both enhanced fluorescence and binding rate indicate that gold nanodisks efficiently improve both detection limit and interaction time for microarrays

  4. Quantification of a cardiac biomarker in human serum using extraordinary optical transmission (EOT.

    Directory of Open Access Journals (Sweden)

    Tao Ding

    Full Text Available Nanoimprinting lithography (NIL is a manufacturing process that can produce macroscale surface areas with nanoscale features. In this paper, this technique is used to solve three fundamental issues for the application of localized surface plasmonic resonance (LSPR in practical clinical measurements: assay sensitivity, chip-to-chip variance, and the ability to perform assays in human serum. Using NIL, arrays of 140 nm square features were fabricated on a sensing area of 1.5 mm x 1.5 mm with low cost. The high reproducibility of NIL allowed for the use of a one-chip, one-measurement approach with 12 individually manufactured surfaces with minimal chip-to-chip variations. To better approximate a real world setting, all chips were modified with a biocompatible, multi-component monolayer and inter-chip variability was assessed by measuring a bioanalyte standard (2.5-75 ng/ml in the presence of a complex biofluid, human serum. In this setting, nanoimprinted LSPR chips were able to provide sufficient characteristics for a 'low-tech' approach to laboratory-based bioanalyte measurement, including: 1 sufficient size to interface with a common laboratory light source and detector without the need for a microscope, 2 high sensitivity in serum with a cardiac troponin limit of detection of 0.55 ng/ml, and 3 very low variability in chip manufacturing to produce a figure of merit (FOM of 10.5. These findings drive LSPR closer to technical comparability with ELISA-based assays while preserving the unique particularities of a LSPR based sensor, suitability for multiplexing and miniaturization, and point-of-care detections.

  5. Metastable argon atom density in complex argon/acetylene plasmas determined by means of optical absorption and emission spectroscopy

    International Nuclear Information System (INIS)

    Sushkov, Vladimir; Herrendorf, Ann-Pierra; Hippler, Rainer

    2016-01-01

    Optical emission and absorption spectroscopy has been utilized to investigate the instability of acetylene-containing dusty plasmas induced by growing nano-particles. The density of Ar(1s 5 ) metastable atoms was derived by two methods: tunable diode laser absorption spectroscopy and with the help of the branching ratio method of emitted spectral lines. Results of the two techniques agree well with each other. The density of Ar(1s 3 ) metastable atoms was also measured by means of optical emission spectroscopy. The observed growth instability leads to pronounced temporal variations of the metastable and other excited state densities. An analysis of optical line ratios provides evidence for a depletion of free electrons during the growth cycle but no indication for electron temperature variations. (paper)

  6. An insight into the optical properties of CdSe quantum dots during their growth in bovine serum albumin solution

    International Nuclear Information System (INIS)

    Singh, Avinash; Ahmed, M.; Guleria, A.; Singh, A.K.; Adhikari, S.; Rath, M.C.

    2016-01-01

    Bovine serum albumin (BSA) assisted synthesis of cadmium selenide (CdSe) quantum dots (QDs) exhibits remarkable changes in the optical properties of the QDs as well as BSA during their growth. The growth of these QDs was investigated by recording the UV–visible absorption spectra and room temperature steady state fluorescence at different time intervals after the mixing of the precursors. The growth of these QDs was associated with a quenching of the fluorescence from BSA. The fluorescence from these QDs was found to be associated with several features: (1) a gradual red-shift in its peak position, (2) increase in intensity with an isoemissive point up to few minutes from the time of mixing of the two precursors, and (3) subsequent decrease in intensity reaching a minimum value, which remains almost unchanged thereafter. The decrease and increase in the fluorescence from BSA and CdSe QDs, respectively have been explained on the basis of Förster resonance energy transfer (FRET) as well as the simultaneous growth of these QDs. - Highlights: • CdSe quantum dots were synthesized in the presence of bovine serum albumin (BSA). • Fluorescence from BSA was quenched by during the growth of CdSe quantum dots. • There was an energy transfer from BSA to CdSe quantum dots during their growth. • The emission from CdSe quantum dots was associated with a red-shift.

  7. Optical Extinction Measurements of Dust Density in the GMRO Regolith Test Bin

    Science.gov (United States)

    Lane, J.; Mantovani, J.; Mueller, R.; Nugent, M.; Nick, A.; Schuler, J.; Townsend, I.

    2016-01-01

    A regolith simulant test bin was constructed and completed in the Granular Mechanics and Regolith Operations (GMRO) Lab in 2013. This Planetary Regolith Test Bed (PRTB) is a 64 sq m x 1 m deep test bin, is housed in a climate-controlled facility, and contains 120 MT of lunar-regolith simulant, called Black Point-1 or BP-1, from Black Point, AZ. One of the current uses of the test bin is to study the effects of difficult lighting and dust conditions on Telerobotic Perception Systems to better assess and refine regolith operations for asteroid, Mars and polar lunar missions. Low illumination and low angle of incidence lighting pose significant problems to computer vision and human perception. Levitated dust on Asteroids interferes with imaging and degrades depth perception. Dust Storms on Mars pose a significant problem. Due to these factors, the likely performance of telerobotics is poorly understood for future missions. Current space telerobotic systems are only operated in bright lighting and dust-free conditions. This technology development testing will identify: (1) the impact of degraded lighting and environmental dust on computer vision and operator perception, (2) potential methods and procedures for mitigating these impacts, (3) requirements for telerobotic perception systems for asteroid capture, Mars dust storms and lunar regolith ISRU missions. In order to solve some of the Telerobotic Perception system problems, a plume erosion sensor (PES) was developed in the Lunar Regolith Simulant Bin (LRSB), containing 2 MT of JSC-1a lunar simulant. PES is simply a laser and digital camera with a white target. Two modes of operation have been investigated: (1) single laser spot - the brightness of the spot is dependent on the optical extinction due to dust and is thus an indirect measure of particle number density, and (2) side-scatter - the camera images the laser from the side, showing beam entrance into the dust cloud and the boundary between dust and void. Both

  8. Effect of wetting-layer density of states on the gain and phase recovery dynamics of quantum-dot semiconductor optical amplifiers

    International Nuclear Information System (INIS)

    Kim, Jungho; Yu, Bong-Ahn

    2015-01-01

    We numerically investigate the effect of the wetting-layer (WL) density of states on the gain and phase recovery dynamics of quantum-dot semiconductor optical amplifiers in both electrical and optical pumping schemes by solving 1088 coupled rate equations. The temporal variations of the ultrafast gain and phase recovery responses at the ground state (GS) are calculated as a function of the WL density of states. The ultrafast gain recovery responses do not significantly depend on the WL density of states in the electrical pumping scheme and the three optical pumping schemes such as the optical pumping to the WL, the optical pumping to the excited state ensemble, and the optical pumping to the GS ensemble. The ultrafast phase recovery responses are also not significantly affected by the WL density of states except the optical pumping to the WL, where the phase recovery component caused by the WL becomes slowed down as the WL density of states increases. (paper)

  9. Estimation of macular pigment optical density in the elderly: test-retest variability and effect of optical blur in pseudophakic subjects

    NARCIS (Netherlands)

    Gallaher, Kevin T.; Mura, Marco; Todd, Wm Andrew; Harris, Tarsha L.; Kenyon, Emily; Harris, Tamara; Johnson, Karen C.; Satterfield, Suzanne; Kritchevsky, Stephen B.; Iannaccone, Alessandro

    2007-01-01

    The reproducibility of macular pigment optical density (MPOD) estimates in the elderly was assessed in 40 subjects (age: 79.1+/-3.5). Test-retest variability was good (Pearson's r coefficient: 0.734), with an average coefficient of variation (CV) of 18.4% and an intraclass correlation coefficient

  10. Association between lumbar bone mineral density and serum uric acid in postmenopausal women: a cross-sectional study of healthy Chinese population.

    Science.gov (United States)

    Han, Wen; Bai, Xiaojuan; Wang, Nan; Han, Lulu; Sun, Xuefeng; Chen, Xiangmei

    2017-12-01

    Partial correlation and regression analyses were used in this study. We showed that there is a linear relationship between bone mineral density and serum uric acid within the normal physiologic range, and higher serum uric acid levels had a protective effect on bone loss in postmenopausal osteoporosis. The significance of the relationship between lumbar bone mineral density ( BMD) and serum uric acid (SUA) levels is unclear. The aims of this study were to investigate on a population-level the association between lumbar BMD and SUA within the normal physiologic range and to determine whether SUA plays a protective role in bone loss in healthy postmenopausal Chinese women. This was a community-based cross-sectional study involving 390 healthy postmenopausal women, 47-89 years of age, conducted in Shenyang, China. The BMD was measured at the lumbar spine using dual-energy X-ray absorptiometry (DXA). The SUA levels were obtained at each DXA visit. Partial correlation and regression analyses were applied to determine the associations. The SUA levels were significantly different between the normal BMD, osteopenia, and osteoporosis groups. The lumbar BMD was positively correlated with SUA in postmenopausal women after adjustment for age (r = 0.212). After adjustment for age, body mass index, systolic blood pressure, diastolic blood pressure, hip circumference, cigarette smoking, alcohol consumption, milk intake, physical exercise, fracture history, total protein, total bilirubin, triglycerides, total cholesterol, high-density lipoprotein cholesterol, fasting blood glucose, serum calcium, and estimated glomerular filtration rate, the lumbar BMD was associated with SUA and the odds ratio of the third SUA quartile was 0.408 (95%CI, 0.198-0.841, P = 0.015), compared to the first quartile of SUA levels. The lumbar BMD was linearly associated with SUA levels within the normal physiologic range of postmenopausal women. Higher SUA levels had a protective effect on bone loss

  11. Optical excitation and electron relaxation dynamics at semiconductor surfaces: a combined approach of density functional and density matrix theory applied to the silicon (001) surface

    Energy Technology Data Exchange (ETDEWEB)

    Buecking, N

    2007-11-05

    In this work a new theoretical formalism is introduced in order to simulate the phononinduced relaxation of a non-equilibrium distribution to equilibrium at a semiconductor surface numerically. The non-equilibrium distribution is effected by an optical excitation. The approach in this thesis is to link two conventional, but approved methods to a new, more global description: while semiconductor surfaces can be investigated accurately by density-functional theory, the dynamical processes in semiconductor heterostructures are successfully described by density matrix theory. In this work, the parameters for density-matrix theory are determined from the results of density-functional calculations. This work is organized in two parts. In Part I, the general fundamentals of the theory are elaborated, covering the fundamentals of canonical quantizations as well as the theory of density-functional and density-matrix theory in 2{sup nd} order Born approximation. While the formalism of density functional theory for structure investigation has been established for a long time and many different codes exist, the requirements for density matrix formalism concerning the geometry and the number of implemented bands exceed the usual possibilities of the existing code in this field. A special attention is therefore attributed to the development of extensions to existing formulations of this theory, where geometrical and fundamental symmetries of the structure and the equations are used. In Part II, the newly developed formalism is applied to a silicon (001)surface in a 2 x 1 reconstruction. As first step, density-functional calculations using the LDA functional are completed, from which the Kohn-Sham-wave functions and eigenvalues are used to calculate interaction matrix elements for the electron-phonon-coupling an the optical excitation. These matrix elements are determined for the optical transitions from valence to conduction bands and for electron-phonon processes inside the

  12. Shack-Hartmann Electron Densitometer (SHED): An Optical System for Diagnosing Free Electron Density in Laser-Produced Plasmas

    Science.gov (United States)

    2016-11-01

    Free Electron Density in Laser-Produced Plasmas by Anthony R Valenzuela Approved for public release; distribution is...AND SUBTITLE Shack-Hartmann Electron Densitometer (SHED): An Optical System for Diagnosing Free Electron Density in Laser-Produced Plasmas 5a...SUPPLEMENTARY NOTES 14. ABSTRACT The Shack-Hartmann Electron Densitometer is a novel method to diagnose ultrashort pulse laser–produced plasmas

  13. Optical, structural and thermodynamic properties of the interaction between tradimefon and serum albumin

    Science.gov (United States)

    Zhang, Hua-xin; Mei, Ping; Yang, Xi-xiong

    2009-04-01

    The biological toxicity of a chloric pesticide, tradimefon to bovine serum albumin (BSA) were studied by fluorescence and absorption spectroscopy. The fluorescence quenching mechanism analysis indicates the quenching of BSA by TDF was caused by BSA-TDF complex formation and electrostatic interaction played major role in the reaction. The number of binding sites n and observed binding constant Kb was measured by fluorescence quenching method. The thermodynamic parameters Δ Hθ, Δ Gθ, Δ Sθ at different temperatures were calculated, and the distance r between donor (BSA) and acceptor (TDF) was obtained according to Förster theory of non-radiation energy transfer. Three-dimensional fluorescence spectra, circular dichroism (CD) spectra and synchronous fluorescence spectra were used to investigate the structural change of BSA molecules with addition of TDF and the mechanism of binding reaction was analyzed at molecular level.

  14. Measurement of carbon nanotube microstructure relative density by optical attenuation and observation of size-dependent variations.

    Science.gov (United States)

    Park, Sei Jin; Schmidt, Aaron J; Bedewy, Mostafa; Hart, A John

    2013-07-21

    Engineering the density of carbon nanotube (CNT) forest microstructures is vital to applications such as electrical interconnects, micro-contact probes, and thermal interface materials. For CNT forests on centimeter-scale substrates, weight and volume can be used to calculate density. However, this is not suitable for smaller samples, including individual microstructures, and moreover does not enable mapping of spatial density variations within the forest. We demonstrate that the relative mass density of individual CNT microstructures can be measured by optical attenuation, with spatial resolution equaling the size of the focused spot. For this, a custom optical setup was built to measure the transmission of a focused laser beam through CNT microstructures. The transmittance was correlated with the thickness of the CNT microstructures by Beer-Lambert-Bouguer law to calculate the attenuation coefficient. We reveal that the density of CNT microstructures grown by CVD can depend on their size, and that the overall density of arrays of microstructures is affected significantly by run-to-run process variations. Further, we use the technique to quantify the change in CNT microstructure density due to capillary densification. This is a useful and accessible metrology technique for CNTs in future microfabrication processes, and will enable direct correlation of density to important properties such as stiffness and electrical conductivity.

  15. Optical and Morphological Properties of Electron-Beam Irradiated High-Density Thin Poly Ethylene Films

    International Nuclear Information System (INIS)

    Abdel-Hamid, H. M.; Fawzy, Y.H.A.; El-Sayed, S.M.

    2005-01-01

    Effects of surface morphology alterations on the optical properties of the high-density polyethylene (HDPE) films irradiated by 1.5 MeV electron beam has been investigated. The irradiation doses were conducted at the values: 30, 135, 295 and 540 kGy, respectively. The changes induced in HDPE involved: the creation of free radicals, the formation of chemical bonds i.e., intermolecular crosslinking and irreversible cleavage of bonds in the main chain, which resulted in the fragmentation of the molecules. An Ultraviolet-Visible Spectrophotometer (UV-VIS) and Scanning Electron Microscope (SEM) were used to characterize the changes. Because the crosslinking (induced by electron irradiation) limits the movability of the HDPE molecular chains, the optical energy gap was then subjected to a change. It decreased from 4.41 to 3.22 eV with an increasing electron dose up to 540 kGy. At a higher dose of irradiation (540 kGy), degradation of HDPE rather than crosslinking was raised. The irradiated HDPE films indicated that the crosslinking and degradation are likely to have an effect on their surface morphologies. The physical properties of polymeric materials can be modified by ionizing radiation in the form of gamma rays, X-rays and energetic electrons. High-energy electron beam is an especially useful tool in this regard (Cleland et al, 2003). Polymerizing, grafting, crosslinking and chain scission reactions can be initiated by irradiation. The results of such reactions can enhance the utility and value of commercial products. HDPE (CH2-CH2) has many attractive properties, such as an excellent chemical resistance, low friction and low moisture absorption

  16. Macular pigment optical density spatial distribution measured in a subject with oculocutaneous albinism.

    Science.gov (United States)

    Putnam, Christopher M; Bland, Pauline J

    2014-01-01

    Previous studies of macular pigment optical density (MPOD) distribution in individuals with oculocutaneous albinism (OCA) have primarily used objective measurement techniques including fundus reflectometry and autofluorescence. We report here on a subject with OCA and their corresponding MPOD distribution assessed through heterochromatic flicker photometry (HFP). A subject with a history of OCA presented with an ocular history including strabismus surgery of the LE with persistent amblyopia and mild, latent nystagmus. Best corrected visual acuity was 20/25- RE and 20/40- LE. Spectral domain optical coherence tomography (SD-OCT) and fundus photography were also obtained. Evaluation of MPOD spatial distribution up to 8 degrees eccentricity from the fovea was performed using HFP. SD-OCT indicated a persistence of multiple inner retinal layers within the foveal region in the RE and LE including symmetric foveal thickening consistent with foveal hypoplasia. Fundus photography showed mild retinal pigmented epithelial (RPE) hypopigmentation and a poorly demarcated macula. OriginPro 9 was used to plot MPOD spatial distribution of the subject and a 33-subject sample. The OCA subject demonstrated a foveal MPOD of 0.10 with undetectable levels at 6 degrees eccentricity. The study sample showed a mean foveal MPOD of 0.34 and mean 6 degree eccentricity values of 0.03. Consistent with previous macular pigment (MP) studies of OCA, overall MPOD is reduced in our subject. Mild phenotypic expression of OCA with high functional visual acuity may represent a Henle fiber layer amenable to additional MP deposition. Further study of MP supplementation in OCA patients is warranted. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Assessment risk of osteoporosis in Chinese people: relationship among body mass index, serum lipid profiles, blood glucose, and bone mineral density

    Directory of Open Access Journals (Sweden)

    Cui RT

    2016-07-01

    Full Text Available Rongtao Cui,1 Lin Zhou,2 Zuohong Li,2 Qing Li,2 Zhiming Qi,2 Junyong Zhang3 1Department of Orthopedic and Trauma Surgery, Surgical Research, Duisburg-Essen University Hospital, Essen, Germany; 2Department of Orthopedics, Dalian Central Hospital, Dalian, 3Department of Gastroenterology, Shandong Provincial Hospital, Jinan, People’s Republic of China Objective: The aim of our study was to investigate the relationship among age, sex, body mass index (BMI, serum lipid profiles, blood glucose (BG, and bone mineral density (BMD, making an assessment of the risk of osteoporosis.Materials and methods: A total of 1,035 male and 3,953 female healthy volunteers (aged 41–95 years were recruited by an open invitation. The basic information, including age, sex, height, weight, waistline, hipline, menstrual cycle, and medical history, were collected by a questionnaire survey and physical examination. Serum lipid profiles, BG, postprandial blood glucose, and glycosylated hemoglobin were obtained after 12 hours fasting. BMD in lumbar spine was measured by dual-energy X-ray absorptiometry scanning.Results: The age-adjusted BMD in females was significantly lower than in males. With aging, greater differences of BMD distribution exist in elderly females than in males (P<0.001, and the fastigium of bone mass loss was in the age range from 51 to 55 in females and from 61 to 65 years in males. After adjustment for sex, there were significant differences in BMD among BMI-stratified groups in both males and females. The subjects with a BMI of <18.5 had a higher incidence of osteoporosis than BMI ≥18.5 in both sexes. BMD in type 2 diabetes mellitus with a BG of >7.0 mmol/L was lower than in people with BG of ≤7.0 mmol/L (P<0.001. People with serum high-density lipoprotein cholesterol levels of ≥1.56 mmol/L had a greater prevalence of osteoporosis compared with high-density lipoprotein cholesterol ≤1.55 mmol/L. Logistic regression with odds ratios showed that

  18. Detection of lipopolysaccharides in serum using a waveguide-based optical biosensor

    Science.gov (United States)

    Noormohamed, Aneesa; Stromberg, Loreen R.; Anderson, Aaron S.; Karim, Zachary; Dighe, Priya; Kempaiah, Prakasha; Ong'echa, John M.; Perkins, Douglas J.; Doggett, Norman; McMahon, Benjamin; Mukundan, Harshini

    2017-02-01

    Direct ultra-sensitive detection of pathogen biomarkers in blood could provide a universal strategy for diagnosis of bacterial infections, which remain a leading cause of morbidity and mortality in many areas of the world. Many factors complicate diagnosis, including the presence of multiple co-infections in a given patient, and lack of infrastructure in rural settings. In some pediatric patients, such as those in areas with poor resources, an additional challenge exists with low sample volumes due to age and other health factors such as anemia and dehydration. Our team is working on developing novel diagnostic assays, with a waveguide-based biosensor platform, to rapidly and specifically identify pathogen biomarkers from small samples of serum or plasma, allowing for the timely and sensitive diagnosis of infection at the point of care. In addition to the platform, we have developed novel membrane insertion and lipoprotein capture assay methods, to capture lipidated pathogen biomarkers in aqueous blood, by virtue of their interactions with host lipoprotein carriers. Herein, we demonstrate our efforts to adapt the lipoprotein capture assay for the detection of small concentrations of pathogen-secreted lipopolysaccharides in aqueous blood, with the ultimate aim of diagnosing Gram-negative infections effectively.

  19. Enhancement of phase space density by increasing trap anisotropy in a magneto-optical trap with a large number of atoms

    International Nuclear Information System (INIS)

    Vengalattore, M.; Conroy, R.S.; Prentiss, M.G.

    2004-01-01

    The phase space density of dense, cylindrical clouds of atoms in a 2D magneto-optic trap is investigated. For a large number of trapped atoms (>10 8 ), the density of a spherical cloud is limited by photon reabsorption. However, as the atom cloud is deformed to reduce the radial optical density, the temperature of the atoms decreases due to the suppression of multiple scattering leading to an increase in the phase space density. A density of 2x10 -4 has been achieved in a magneto-optic trap containing 2x10 8 atoms

  20. Assessment of Different Sampling Methods for Measuring and Representing Macular Cone Density Using Flood-Illuminated Adaptive Optics.

    Science.gov (United States)

    Feng, Shu; Gale, Michael J; Fay, Jonathan D; Faridi, Ambar; Titus, Hope E; Garg, Anupam K; Michaels, Keith V; Erker, Laura R; Peters, Dawn; Smith, Travis B; Pennesi, Mark E

    2015-09-01

    To describe a standardized flood-illuminated adaptive optics (AO) imaging protocol suitable for the clinical setting and to assess sampling methods for measuring cone density. Cone density was calculated following three measurement protocols: 50 × 50-μm sampling window values every 0.5° along the horizontal and vertical meridians (fixed-interval method), the mean density of expanding 0.5°-wide arcuate areas in the nasal, temporal, superior, and inferior quadrants (arcuate mean method), and the peak cone density of a 50 × 50-μm sampling window within expanding arcuate areas near the meridian (peak density method). Repeated imaging was performed in nine subjects to determine intersession repeatability of cone density. Cone density montages could be created for 67 of the 74 subjects. Image quality was determined to be adequate for automated cone counting for 35 (52%) of the 67 subjects. We found that cone density varied with different sampling methods and regions tested. In the nasal and temporal quadrants, peak density most closely resembled histological data, whereas the arcuate mean and fixed-interval methods tended to underestimate the density compared with histological data. However, in the inferior and superior quadrants, arcuate mean and fixed-interval methods most closely matched histological data, whereas the peak density method overestimated cone density compared with histological data. Intersession repeatability testing showed that repeatability was greatest when sampling by arcuate mean and lowest when sampling by fixed interval. We show that different methods of sampling can significantly affect cone density measurements. Therefore, care must be taken when interpreting cone density results, even in a normal population.

  1. Measurement of rhesus monkey (Macaca mulatta) apolipoprotein B in serum by radioimmunoassay: comparison of immunoreactivities of rhesus and human low density lipoproteins

    International Nuclear Information System (INIS)

    Karlin, J.B.; Juhn, D.J.; Fless, G.; Scanu, A.M.; Rubenstein, A.H.

    1978-01-01

    A sensitive and specific double antibody radioimmunoassay for the major apolipoprotein (apoB) of rhesus (Macaca mulatta) serum very low density lipoprotein (VLDL) and low density lipoprotein (LDL) is described. The antiserum was raised to LDL (d 1.030 to 1.040 g/ml) and the LDL 2 (d 1.020 to 1.050 g/ml) was labeled with 125 I by the chloramine-T or iodine monochloride method. The assay, which was sensitive to 0.02 to 0.5 μg of LDL 2 , had an interassay coefficient of variation of 4.5%. This assay was successfully used to measure apoB in the whole serum and low density lipoproteins of control monkeys maintained on a standard Purina monkey chow (PMC) diet and of three groups of monkeys fed atherogenic diets: an average American diet, a 25% peanut oil and 2% cholesterol-supplemented PMC diet, and a 25% coconut oil and 2% cholesterol-supplemented PMC diet

  2. Extended Bose Hubbard model of interacting bosonic atoms in optical lattices: From superfluidity to density waves

    International Nuclear Information System (INIS)

    Mazzarella, G.; Giampaolo, S. M.; Illuminati, F.

    2006-01-01

    For systems of interacting, ultracold spin-zero neutral bosonic atoms, harmonically trapped and subject to an optical lattice potential, we derive an Extended Bose Hubbard (EBH) model by developing a systematic expansion for the Hamiltonian of the system in powers of the lattice parameters and of a scale parameter, the lattice attenuation factor. We identify the dominant terms that need to be retained in realistic experimental conditions, up to nearest-neighbor interactions and nearest-neighbor hoppings conditioned by the on-site occupation numbers. In the mean field approximation, we determine the free energy of the system and study the phase diagram both at zero and at finite temperature. At variance with the standard on site Bose Hubbard model, the zero-temperature phase diagram of the EBH model possesses a dual structure in the Mott insulating regime. Namely, for specific ranges of the lattice parameters, a density wave phase characterizes the system at integer fillings, with domains of alternating mean occupation numbers that are the atomic counterparts of the domains of staggered magnetizations in an antiferromagnetic phase. We show as well that in the EBH model, a zero-temperature quantum phase transition to pair superfluidity is, in principle, possible, but completely suppressed at the lowest order in the lattice attenuation factor. Finally, we determine the possible occurrence of the different phases as a function of the experimentally controllable lattice parameters

  3. Reliability of Heterochromatic Flicker Photometry in Measuring Macular Pigment Optical Density among Preadolescent Children

    Directory of Open Access Journals (Sweden)

    Sasha M. McCorkle

    2015-10-01

    Full Text Available Macular pigment optical density (MPOD—assessed using customized heterochromatic flicker photometry (cHFP—is related to better cognition and brain lutein among adults. However, the reliability of MPOD assessed by cHFP has not been investigated in children. We assessed inter-session reliability of MPOD using modified cHFP. 7–10-year-olds (n = 66 underwent cHFP over 2 visits using 11 examiners. Reliability was also assessed in a subsample (n = 46 with only 2 examiners. Among all participants, there was no significant difference between the two sessions (p = 0.59—session 1: 0.61 ± 0.28; session 2: 0.62 ± 0.27. There was no significant difference in the MPOD of boys vs. girls (p = 0.56. There was a significant correlation between sessions (Y = 0.52x + 0.31; R2 = 0.29, p ≤ 0.005, with a reliability of 0.70 (Cronbach’s α. Among the subsample with 2 examiners, there was a significant correlation between sessions (Y = 0.54x + 0.31; R2 = 0.32, p < 0.005, with a reliability of 0.72 (Cronbach’s α. In conclusion, there is moderate reliability for modified cHFP to measure MPOD in preadolescents. These findings provide support for future studies aiming to conduct noninvasive assessments of retinal xanthophylls and study their association with cognition during childhood.

  4. Calculations of the electronic density of states and conductivity consistent with the generalized optical theorem

    International Nuclear Information System (INIS)

    Oosten, A.B. van; Geertsma, W.

    1985-01-01

    In order to study density of states (DOS) effects on the resistivity of liquid metals and alloys we derive a set of integral equations for these quantities so that this set satisfies the generalized optical theorem. The DOS is calculated up to second order in the scattering potential using renormalized propagators. The theory is applicable to weak scattering systems, for example, alkali and alkaline earth metals and, for example, to Li-Pb alloys for compositions where the mean free path is much larger that the average interatomic distance. From our numerical results we conclude that the Ziman equation for the resistivity should be multiplied by g 2 =N 2 (Esub(F))/N 2 sub(O)(Esub(F)) where N(Esub(F)) is the DOS at the Fermi level as calculated in our model and Nsub(O)(Esub(F)) is the free electron DOS. This solves the long standing problem of whether or not one should correct the Ziman equation by an effective mass correction. Our model is only valid for alloys consisting of atoms with a small difference in electronegativity. This is clearly shown in the results for the liquid Li-Pb system. Some of the existing resistivity theories for weak and intermediate scattering are examined in the light of our calculations. (author)

  5. Changes in peripapillary blood vessel density in Graves' orbitopathy after orbital decompression surgery as measured by optical coherence tomography angiography.

    Science.gov (United States)

    Lewis, Kyle T; Bullock, John R; Drumright, Ryan T; Olsen, Matthew J; Penman, Alan D

    2018-03-08

    The purpose is to evaluate the utility of optical coherence tomography (OCT) angiography in the evaluation of Graves' orbitopathy (GO) and response to orbital decompression in patients with and without dysthyroid optic neuropathy (DON). This was a single-center, prospective case series in a cohort of 12 patients (24 orbits) with GO and ±DON, (6 orbits) who underwent bilateral orbital decompression. All patients underwent pre- and postoperative OCT angiography of the peripapillary area. Vessel density indices were calculated in a 4.5 mm × 4.5 mm ellipsoid centered on the optic disk using split-spectrum amplitude decorrelation angiography algorithm, producing the vessel density measurements. Mean change in vessel density indices was compared between pre- and postoperative sessions and between patients with and without DON. Patient 1, a 34-year-old male with GO and unilateral DON OD, showed a significant reduction in blood vessel density indices oculus dexter (OD) (DON eye) after decompression while a more modest reduction was found oculus sinister (OS) with the greatest change noted intrapapillary. Patient 2, a 50-year-old male with DON OU, showed worsening neuropathy following decompression OD that was confirmed by angiographic density indices. Patient 3, a 55-year-female with DON, showed a reduction in blood vessel density OD and increased density OS. Patients without DON showed overall less impressive changes in indices as compared to those with DON. Using OCT angiography, response to surgical treatment in GO orbits, more so in orbits with DON, can be demonstrated and quantified using vessel density indices with reproducibility.

  6. Age-related changes of serum tartrate-resistant acid phosphatase 5b and the relationship with bone mineral density in Chinese women

    Institute of Scientific and Technical Information of China (English)

    Yue-juan QIN; Zhen-lin ZHANG; Hao ZHANG; Wei-wei HU; Yu-juan LIU; Yun-qiu HU; Miao LI; Jie-mei GU; Jin-wei HE

    2008-01-01

    Aim: Ostcoclastic activity is mainly assessed by measurement of urinary markers (eg C-terminal cross-linked telopeptides of type I collagen, N-terminal cross-linked telopeptides of type I collagen etc), the levels of which could often be affected by renal clearance. Recently, serum tartrate-resistant acid phosphatase 5b (TRACP5b) has been used as an alternative serum marker to evaluate osteoclastic activity. We investigated the age-related changes of TRACP5b level and its association with bone mineral density (BMD) in Chinese women. Methods: Seven-hundred and twenty-two Chinese mainland women aged 20-79 years were recruited in the study. Serum TRACP5b level was measured using immunoassay to evaluate the state of bone resorption. Bone mineral density (BMD) (g/cm2) at lumbar spine 1-4 and proximal femur were measured by duel-energy X-ray absorptiometry. Results: The serum TRACP5b level reached a bottom value in premenopausal women aged 30-39, gradually increased in women aged 40-49, rapidly rose in women aged 50-59, and culminated with a maximum value in women aged 60-69 before a slow drop in women aged 70-79. The average level of TRACPSb was significantly higher in postmenopausal women [(3.29±1.07) U/L] than in premenopausal women ([1.70±0.59] U/L). The levels of TRACP5b were inversely correlated with BMD at all measured sites (P<0.001). Furthermore, the level of TRACP5b was obviously higher in women with osteoporosis and osteopenia than those with normal bone mass (P<0.001). Conclusion: We have established the reference values of serum TRACPSb in Chinese mainland women, and found that postmenopausal women had higher TRACP5b concentration than younger women. The results showed that serum TRACPSb was a sensitive and useful parameter for the evaluation of age-related changes of bone absorption.

  7. Low serum levels of High-Density Lipoprotein cholesterol (HDL-c) as an indicator for the development of severe postpartum depressive symptoms

    Science.gov (United States)

    Ramachandran Pillai, Raji; Wilson, Anand Babu; Premkumar, Nancy R.; Kattimani, Shivanand; Sagili, Haritha

    2018-01-01

    Postpartum depression (PPD) is a psychiatric complication of childbirth affecting 10–20% of new mothers and has negative impact on both mother and infant. Serum lipid levels have been related to depressive disorders, but very limited literatures are available regarding the lipid levels in women with postpartum depression. The present study is aimed to examine the association of serum lipids with the development of postpartum depressive symptoms. This is a cross sectional study conducted at a tertiary care hospital in South India. Women who came for postpartum check-up at 6th week post-delivery were screened for PPD (September 2014-October 2015). Women with depressive symptoms were assessed using EPDS (Edinburgh Postnatal Depression Scale). The study involved 186 cases and 250 controls matched for age and BMI. Serum levels of lipid parameters were estimated through spectrophotometry and the atherogenic indices were calculated in all the subjects. Low serum levels of Total Cholesterol (TC) and High Density Lipoprotein cholesterol (HDL-c) were significantly low in PPD women with severe depressive symptoms. The study recorded a significant negative correlation between HDL-c and the EPDS score in PPD women (r = -0.140, p = 0.05). Interestingly, the study also observed a significant negative correlation between Body Mass Index (BMI) and EPDS scores in case group (r = -0.146, p = 0.047), whereas a positive correlation between the same in controls (r = 0.187, p = 0.004). Our study demonstrated that low levels of serum HDL-c is correlated with the development of severe depressive symptoms in postpartum women. Study highlights the role of lipids in the development of postpartum depressive symptoms. PMID:29444162

  8. Low serum levels of High-Density Lipoprotein cholesterol (HDL-c as an indicator for the development of severe postpartum depressive symptoms.

    Directory of Open Access Journals (Sweden)

    Raji Ramachandran Pillai

    Full Text Available Postpartum depression (PPD is a psychiatric complication of childbirth affecting 10-20% of new mothers and has negative impact on both mother and infant. Serum lipid levels have been related to depressive disorders, but very limited literatures are available regarding the lipid levels in women with postpartum depression. The present study is aimed to examine the association of serum lipids with the development of postpartum depressive symptoms. This is a cross sectional study conducted at a tertiary care hospital in South India. Women who came for postpartum check-up at 6th week post-delivery were screened for PPD (September 2014-October 2015. Women with depressive symptoms were assessed using EPDS (Edinburgh Postnatal Depression Scale. The study involved 186 cases and 250 controls matched for age and BMI. Serum levels of lipid parameters were estimated through spectrophotometry and the atherogenic indices were calculated in all the subjects. Low serum levels of Total Cholesterol (TC and High Density Lipoprotein cholesterol (HDL-c were significantly low in PPD women with severe depressive symptoms. The study recorded a significant negative correlation between HDL-c and the EPDS score in PPD women (r = -0.140, p = 0.05. Interestingly, the study also observed a significant negative correlation between Body Mass Index (BMI and EPDS scores in case group (r = -0.146, p = 0.047, whereas a positive correlation between the same in controls (r = 0.187, p = 0.004. Our study demonstrated that low levels of serum HDL-c is correlated with the development of severe depressive symptoms in postpartum women. Study highlights the role of lipids in the development of postpartum depressive symptoms.

  9. Optical diagnostic of hepatitis B (HBV) and C (HCV) from human blood serum using Raman spectroscopy

    International Nuclear Information System (INIS)

    Anwar, Shahzad; Firdous, Shamaraz

    2015-01-01

    Hepatitis is the second most common disease worldwide with half of the cases arising in the developing world. The mortality associated with hepatitis B and C can be reduced if the disease is detected at the early stages of development. The aim of this study was to investigate the potential of Raman spectroscopy as a diagnostic tool to detect biochemical changes accompanying hepatitis progression. Raman spectra were acquired from 20 individuals with six hepatitis B infected patients, six hepatitis C infected patients and eight healthy patients in order to gain an insight into the determination of biochemical changes for early diagnostic. The human blood serum was examined at a 532 nm excitation laser source. Raman characteristic peaks were observed in normal sera at 1006, 1157 and 1513 cm −1 , while in the case of hepatitis B and C these peaks were found to be blue shifted with decreased intensity. New Raman peaks appeared in HBV and HCV infected sera at 1194, 1302, 844, 905, 1065 and 1303 cm −1 respectively. A Mat lab subroutine and frequency domain filter program is developed and applied to signal processing of Raman scattering data. The algorithms have been successfully applied to remove the signal noise found in experimental scattering signals. The results show that Raman spectroscopy displays a high sensitivity to biochemical changes in blood sera during disease progression resulting in exceptional prediction accuracy when discriminating between normal and malignant. Raman spectroscopy shows enormous clinical potential as a rapid non-invasive diagnostic tool for hepatitis and other infectious diseases. (letter)

  10. Optical diagnostic of hepatitis B (HBV) and C (HCV) from human blood serum using Raman spectroscopy

    Science.gov (United States)

    Anwar, Shahzad; Firdous, Shamaraz

    2015-06-01

    Hepatitis is the second most common disease worldwide with half of the cases arising in the developing world. The mortality associated with hepatitis B and C can be reduced if the disease is detected at the early stages of development. The aim of this study was to investigate the potential of Raman spectroscopy as a diagnostic tool to detect biochemical changes accompanying hepatitis progression. Raman spectra were acquired from 20 individuals with six hepatitis B infected patients, six hepatitis C infected patients and eight healthy patients in order to gain an insight into the determination of biochemical changes for early diagnostic. The human blood serum was examined at a 532 nm excitation laser source. Raman characteristic peaks were observed in normal sera at 1006, 1157 and 1513 cm-1, while in the case of hepatitis B and C these peaks were found to be blue shifted with decreased intensity. New Raman peaks appeared in HBV and HCV infected sera at 1194, 1302, 844, 905, 1065 and 1303 cm-1 respectively. A Mat lab subroutine and frequency domain filter program is developed and applied to signal processing of Raman scattering data. The algorithms have been successfully applied to remove the signal noise found in experimental scattering signals. The results show that Raman spectroscopy displays a high sensitivity to biochemical changes in blood sera during disease progression resulting in exceptional prediction accuracy when discriminating between normal and malignant. Raman spectroscopy shows enormous clinical potential as a rapid non-invasive diagnostic tool for hepatitis and other infectious diseases.

  11. Low density lipoprotein receptor gene Ava II polymorphism and serum lipid levels in the Guangxi Bai Ku Yao and Han populations

    Directory of Open Access Journals (Sweden)

    Wu Dong-Feng

    2011-02-01

    Full Text Available Abstract Background Several common genetic polymorphisms in the low density lipoprotein receptor (LDL-R gene have associated with modifications of serum total cholesterol (TC and low density lipoprotein cholesterol (LDL-C levels, but the results are not consistent in different populations. Bai Ku Yao is a special subgroup of the Yao minority in China. The present study was undertaken to detect the association of LDL-R gene Ava Ⅱ polymorphism and serum lipid levels in the Guangxi Bai Ku Yao and Han populations. Methods A total of 1024 subjects of Bai Ku Yao and 792 participants of Han Chinese were randomly selected from our previous stratified randomized cluster samples. Genotyping of the LDL-R gene Ava Ⅱ polymorphism was performed by polymerase chain reaction and restriction fragment length polymorphism combined with gel electrophoresis, and then confirmed by direct sequencing. Results The levels of serum TC, high density lipoprotein cholesterol (HDL-C, LDL-C, apolipoprotein (Apo A1 and the ratio of ApoA1 to ApoB were lower in Bai Ku Yao than in Han (P - and A+ alleles was 65.5% and 34.5% in Bai Ku Yao, and 80.7% and 19.3% in Han (P -A-, A-A+ and A+A+ genotypes was 42.6%, 45.9% and 11.5% in Bai Ku Yao, and 64.9%, 31.6% and 3.5% in Han (P P 3.20 mmol/L subgroups in Bai Ku Yao (P P P P +A+ genotype had higher serum LDL-C, TC, HDL-C or ApoA1 levels than the subjects with A-A+ and A-A- genotypes. Spearman rank correlation analysis revealed that the levels of LDL-C in Bai Ku Yao and HDL-C in Han were correlated with genotypes (P P Conclusions The association of LDL-R gene Ava Ⅱ polymorphism and serum lipid levels is different between the Bai Ku Yao and Han populations. The discrepancy might partly result from different LDL-R gene Ava Ⅱ polymorphism or LDL-R gene-enviromental interactions.

  12. Novel silica surface charge density mediated control of the optical properties of embedded optically active materials and its application for fiber optic pH sensing at elevated temperatures.

    Science.gov (United States)

    Wang, Congjun; Ohodnicki, Paul R; Su, Xin; Keller, Murphy; Brown, Thomas D; Baltrus, John P

    2015-02-14

    Silica and silica incorporated nanocomposite materials have been extensively studied for a wide range of applications. Here we demonstrate an intriguing optical effect of silica that, depending on the solution pH, amplifies or attenuates the optical absorption of a variety of embedded optically active materials with very distinct properties, such as plasmonic Au nanoparticles, non-plasmonic Pt nanoparticles, and the organic dye rhodamine B (not a pH indicator), coated on an optical fiber. Interestingly, the observed optical response to varying pH appears to follow the surface charge density of the silica matrix for all the three different optically active materials. To the best of our knowledge, this optical effect has not been previously reported and it appears universal in that it is likely that any optically active material can be incorporated into the silica matrix to respond to solution pH or surface charge density variations. A direct application of this effect is for optical pH sensing which has very attractive features that can enable minimally invasive, remote, real time and continuous distributed pH monitoring. Particularly, as demonstrated here, using highly stable metal nanoparticles embedded in an inorganic silica matrix can significantly improve the capability of pH sensing in extremely harsh environments which is of increasing importance for applications in unconventional oil and gas resource recovery, carbon sequestration, water quality monitoring, etc. Our approach opens a pathway towards possible future development of robust optical pH sensors for the most demanding environmental conditions. The newly discovered optical effect of silica also offers the potential for control of the optical properties of optically active materials for a range of other potential applications such as electrochromic devices.

  13. Lateral phase drift of the topological charge density in stochastic optical fields

    CSIR Research Space (South Africa)

    Roux, FS

    2012-03-01

    Full Text Available The statistical distributions of optical vortices or topological charge in stochastic optical fields can be inhomogeneous in both transverse directions. Such two-dimensional inhomogeneous vortex or topological charge distributions evolve in a...

  14. Erratum: "Space Density of Optically Selected Type 2 Quasars" (2008, AJ, 136, 2373)

    Science.gov (United States)

    Reyes, Reinabelle; Zakamska, Nadia L.; Strauss, Michael A.; Green, Joshua; Krolik, Julian H.; Shen, Yue; Richards, Gordon T.; Anderson, Scott F.; Schneider, Donald P.

    2010-03-01

    Figure 12 of the paper "Space Density of Optically Selected Type 2 Quasars" compares the obscured quasar fractions derived in our work with those of other studies. Unfortunately, some of the points from these other studies were shown incorrectly. Specifically, the results from X-ray data—Hasinger (2004; open circles) and Ueda et al. (2003; open squares)—which we had taken from Figure 16 of Hopkins et al. (2006), were affected by a luminosity conversion error, in the sense that the displayed luminosities for these data were too high by ~1 dex. With this erratum, we correct this problem and update the figure. The new version (Figure 12) shows more recent results from Hasinger (2008), in lieu of the Hasinger (2004) data points. These are based on data in the redshift range z = 0.2-3.2 (open circles) in that work. The best linear fit to these data (black dashed line) is consistent with that derived for the redshift slice z = 0.4-0.8, which overlaps with the highest redshift bin in our study, and is higher than that derived for redshifts smaller than 0.4 (corresponding to a shift of ~0.7 dex in luminosity). Figure 12 also shows estimates of the obscured quasar fraction derived from the ratio of IR to bolometric luminosities of an AGN sample at redshift z ~ 1 (Treister et al. 2008; filled triangles). Because the obscured quasar fractions derived from our analysis (colored arrows) are strict lower limits, there was already a hint in the previous version of Figure 12 that at high quasar luminosities, we find higher obscured quasar fractions than X-ray surveys. The correction and updates of Figure 12 strengthen this conclusion. At face value, our derived obscured quasar fractions are consistent with those from IR data (Treister et al. 2008; filled triangles). However, we find that they are significantly higher than those derived from X-ray surveys at L_[O\\,\\mathsc {iii]}\\gtrsim 10^{9.5}\\;L_{\\odot }, especially those from the recent analysis by Hasinger (2008). This

  15. Symmetry energy, its density slope, and neutron-proton effective mass splitting at normal density extracted from global nucleon optical potentials

    International Nuclear Information System (INIS)

    Xu Chang; Li Baoan; Chen Liewen

    2010-01-01

    Based on the Hugenholtz-Van Hove theorem, it is shown that both the symmetry energy E sym (ρ) and its density slope L(ρ) at normal density ρ 0 are completely determined by the nucleon global optical potentials. The latter can be extracted directly from nucleon-nucleus scatterings, (p,n) charge-exchange reactions, and single-particle energy levels of bound states. Averaging all phenomenological isovector nucleon potentials constrained by world data available in the literature since 1969, the best estimates of E sym (ρ 0 )=31.3 MeV and L(ρ 0 )=52.7 MeV are simultaneously obtained. Moreover, the corresponding neutron-proton effective mass splitting in neutron-rich matter of isospin asymmetry δ is estimated to be (m n * -m p * )/m=0.32δ.

  16. Macular pigment optical density is positively associated with academic performance among preadolescent children.

    Science.gov (United States)

    Barnett, Sasha M; Khan, Naiman A; Walk, Anne M; Raine, Lauren B; Moulton, Christopher; Cohen, Neal J; Kramer, Arthur F; Hammond, Billy R; Renzi-Hammond, Lisa; Hillman, Charles H

    2017-05-23

    Macular pigment optical density (MPOD) - a non-invasive indicator of retinal xanthophylls and correlate of brain lutein - has been associated with superior cognitive function among adult populations. Given that lutein accumulation in the brain occurs in early life, it is possible that the cognitive implications of greater MPOD may be evident in childhood. Participants aged 8-9 years (n = 56) completed MPOD measurements via heterochromatic flicker photometry. Academic performance was assessed using the Kaufman Test of Academic and Educational Achievement II (KTEA). Habitual dietary intake of L and Z was measured among a subsample of participants (n = 35) using averaged 3-day food records. Stepwise hierarchical regression models were developed to determine the relationship between MPOD and academic achievement tests, following the adjustment of key covariates including sex, aerobic fitness, body composition, and intelligence quotient (IQ). The regression analyses revealed that MPOD improved the model, beyond the covariates, for overall academic achievement (ΔR 2  = 0.10, P mathematics (ΔR 2  = 0.07, P = 0.02), and written language composite standard scores (ΔR 2  = 0.15, P < 0.01). This is the first study to demonstrate that retinal L and Z, measured as MPOD, is positively related to academic achievement in children, even after accounting for the robust effects of IQ and other demographic factors. These findings extend the positive associations observed between MPOD and cognitive abilities to a pediatric population. Trail registration: The Fitness Improves Thinking in Kids 2 (FITKids2) trial was registered at www.clinicaltrials.gov as NCT01619826.

  17. Influence of macular pigment optical density spatial distribution on intraocular scatter.

    Science.gov (United States)

    Putnam, Christopher M; Bland, Pauline J; Bassi, Carl J

    This study evaluated the summed measures of macular pigment optical density (MPOD) spatial distribution and their effects on intraocular scatter using a commercially available device (C-Quant, Oculus, USA). A customized heterochromatic flicker photometer (cHFP) device was used to measure MPOD spatial distribution across the central 16° using a 1° stimulus. MPOD was calculated as a discrete measure and summed measures across the central 1°, 3.3°, 10° and 16° diameters. Intraocular scatter was determined as a mean of 5 trials in which reliability and repeatability measures were met using the C-Quant. MPOD spatial distribution maps were constructed and the effects of both discrete and summed values on intraocular scatter were examined. Spatial mapping identified mean values for discrete MPOD [0.32 (s.d.=0.08)], MPOD summed across central 1° [0.37 (s.d.=0.11)], MPOD summed across central 3.3° [0.85 (s.d.=0.20)], MPOD summed across central 10° [1.60 (s.d.=0.35)] and MPOD summed across central 16° [1.78 (s.d.=0.39)]. Mean intraocular scatter was 0.83 (s.d.=0.16) log units. While there were consistent trends for an inverse relationship between MPOD and scatter, these relationships were not statistically significant. Correlations between the highest and lowest quartiles of MPOD within the central 1° were near significance. While there was an overall trend of decreased intraocular forward scatter with increased MPOD consistent with selective short wavelength visible light attenuation, neither discrete nor summed values of MPOD significantly influence intraocular scatter as measured by the C-Quant device. Published by Elsevier España, S.L.U.

  18. The bone mass density in men aged over 50 and its relation to the concentration of free and total testosterone in the blood serum

    International Nuclear Information System (INIS)

    Purzycka-Jazdon, A.; Lasek, W.; Serafin, Z.; Manysiak, S.

    2003-01-01

    As the mean length of life increases, osteoporosis affects a growing number of men and women, thus becoming an important medical and socioeconomic problem in many countries. Pathogenesis and the prevalence of the osteoporosis in women are well established, however, in men, they are still controversial. In this study, the bone mass density (BMD) of the lumbar spine was determined in 100 healthy men age 50-83, using quantitative computed tomography (QCT). Also, the total serum and free testosterone was measured. The mean BMD was 123.1I39.3 mg/cm 3 , and the values below a fracture threshold were noted in 39% of subjects. The mean concentration of total and free serum testosterone was 4.3I1.7 ng/ml and 6.2I3.7 pg/ml, respectively. There was a significant (p 3 , respectively). There was no correlation found between total testosterone and BMD. Results indicate that reduced bone mass density in males over 50 is as frequent as recently reported in females. Moreover, sex hormones seem to be related to osteoporosis development in men as well. (author)

  19. Functional autonomy, bone mineral density (BMD) and serum osteocalcin levels in older female participants of an aquatic exercise program (AAG).

    Science.gov (United States)

    Pernambuco, Carlos Soares; Borba-Pinheiro, Claudio Joaquim; Vale, Rodrigo Gomes de Souza; Di Masi, Fabrizio; Monteiro, Paola Karynne Pinheiro; Dantas, Estelio H M

    2013-01-01

    The aim of the present study was to evaluate the effects of an AAG on BMD, osteocalcin and functional autonomy in older women. The sample consisted of eighty-two post-menopausal women with low BMD, randomly divided into two groups: the Aquatic Aerobics Group [AAG; n=42; age: 66.8±4.2years], submitted to two weekly sessions over eight months, and the Control Group (GC; n=42; age: 66.9±3.2years), which did not participate in regular exercise. BMD was measured by Dual Energy X-ray Absorptiometry [DXA] of the lumbar and femur, and serum osteocalcin was measured using electrochemiluminescence. A functional autonomy assessment protocol (GDLAM, 2004) was also applied. Statistical analyses used were repeated measures ANOVA and Tukey's post hoc tests. The results showed a significant improvement in tests following the GDLAM protocol: 10 meters walk (10mw) -p=0.003; rising from a ventral decubitus position (RVDP) - Δ%=0.78, pAAG when compared to the CG. The AAG achieved the best results for BMD; however, no inter or intragroup statistical differences were recorded for total femur -p=0.975 and lumbar L(2)-L(4)p=0.597. For serum osteocalcin, intra and intergroup statistical differences of p=0.042 and p=0.027 were observed in the AAG, respectively. This demonstrates that an eight-month aquatic aerobic exercise program can improve functional autonomy and osteocalcin levels, although training did not improve lumbar and total femur BMD in the older women. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry.

    Science.gov (United States)

    Desroches, Joannie; Bouchard, Hugo; Lacroix, Frédéric

    2010-04-01

    The purpose of this study is to determine the effect on the measured optical density of scanning on either side of a Gafchromic EBT and EBT2 film using an Epson (Epson Canada Ltd., Toronto, Ontario) 10000XL flat bed scanner. Calibration curves were constructed using EBT2 film scanned in landscape orientation in both reflection and transmission mode on an Epson 10000XL scanner. Calibration curves were also constructed using EBT film. Potential errors due to an optical density difference from scanning the film on either side ("face up" or "face down") were simulated. Scanning the film face up or face down on the scanner bed while keeping the film angular orientation constant affects the measured optical density when scanning in reflection mode. In contrast, no statistically significant effect was seen when scanning in transmission mode. This effect can significantly affect relative and absolute dose measurements. As an application example, the authors demonstrate potential errors of 17.8% by inverting the film scanning side on the gamma index for 3%-3 mm criteria on a head and neck intensity modulated radiotherapy plan, and errors in absolute dose measurements ranging from 10% to 35% between 2 and 5 Gy. Process consistency is the key to obtaining accurate and precise results in Gafchromic film dosimetry. When scanning in reflection mode, care must be taken to place the film consistently on the same side on the scanner bed.

  1. Technical Note: Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry

    International Nuclear Information System (INIS)

    Desroches, Joannie; Bouchard, Hugo; Lacroix, Frederic

    2010-01-01

    Purpose: The purpose of this study is to determine the effect on the measured optical density of scanning on either side of a Gafchromic EBT and EBT2 film using an Epson (Epson Canada Ltd., Toronto, Ontario) 10000XL flat bed scanner. Methods: Calibration curves were constructed using EBT2 film scanned in landscape orientation in both reflection and transmission mode on an Epson 10000XL scanner. Calibration curves were also constructed using EBT film. Potential errors due to an optical density difference from scanning the film on either side (''face up'' or ''face down'') were simulated. Results: Scanning the film face up or face down on the scanner bed while keeping the film angular orientation constant affects the measured optical density when scanning in reflection mode. In contrast, no statistically significant effect was seen when scanning in transmission mode. This effect can significantly affect relative and absolute dose measurements. As an application example, the authors demonstrate potential errors of 17.8% by inverting the film scanning side on the gamma index for 3%--3 mm criteria on a head and neck intensity modulated radiotherapy plan, and errors in absolute dose measurements ranging from 10% to 35% between 2 and 5 Gy. Conclusions: Process consistency is the key to obtaining accurate and precise results in Gafchromic film dosimetry. When scanning in reflection mode, care must be taken to place the film consistently on the same side on the scanner bed.

  2. Density functional study of electronic structure, elastic and optical properties of MNH2 (M=Li, Na, K, Rb)

    International Nuclear Information System (INIS)

    Babu, K Ramesh; Vaitheeswaran, G

    2014-01-01

    We report a systematic first principles density functional study on the electronic structure, elastic and optical properties of nitrogen based solid hydrogen storage materials LiNH 2 , NaNH 2 , KNH 2 , and RbNH 2 . The ground state structural properties are calculated by using standard density functional theory, and also dispersion corrected density functional theory. We find that van der Waals interactions are dominant in LiNH 2 whereas they are relatively weak in other alkali metal amides. The calculated elastic constants show that all the compounds are mechanically stable and LiNH 2 is found to be a stiffer material among the alkali metal amides. The melting temperatures are calculated and follow the order RbNH 2 2 2 2 . The electronic band structure is calculated by using the Tran–Blaha modified Becke–Johnson potential and found that all the compounds are insulators, with a considerable band gap. The [NH 2 ] − derived states completely dominate in the entire valence band region while the metal atom states occupy the conduction band. The calculated band structure is used to analyze the different interband optical transitions occurring between valence and conduction bands. Our calculations show that these materials have considerable optical anisotropy. (paper)

  3. Enhanced density of optical data storage using near-field concept: fabrication and test of nanometric aperture array

    International Nuclear Information System (INIS)

    Cha, J.; Park, J. H.; Kim, Myong R.; Jhe, W.

    1999-01-01

    We have tried to enhance the density of the near-field optical memory and to improve the recording/readout speed. The current optical memory has the limitation in both density and speed. This barrier due to the far-field nature can be overcome by the use of near-field. The optical data storage density can be increased by reducing the size of the nanometric aperture where the near-field is obtained. To fabricate the aperture in precise dimension, we applied the orientation-dependent / anisotropic etching property of crystal Si often employed in the field of MEMS. And so we fabricated the 10 x 10 aperture array. This array will be also the indispensable part for speeding up. One will see the possibility of the multi-tracking pickup in the phase changing type memory through this array. This aperture array will be expected to write the bit-mark whose size is about 100 nm. We will show the recent result obtained. (author)

  4. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    International Nuclear Information System (INIS)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-01-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band (<5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is -110 dB/Hz, with uncertainty ≤0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by ≤0.2 dB. [copyright] 2001 Optical Society of America

  5. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    Energy Technology Data Exchange (ETDEWEB)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-06-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band ({lt}5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is {minus}110 dB/Hz, with uncertainty {le}0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by {le}0.2 dB. {copyright} 2001 Optical Society of America

  6. EFEK PEMBERIAN SUSU SAPI BUBUK TERHADAP KADAR SERUM HDL (HIGH DENSITY LIPOPROTEIN PADA TIKUS PUTIH (Rattus norvegicus GALUR WISTAR MODEL DIABETES MELITUS TIPE 2

    Directory of Open Access Journals (Sweden)

    Zakia Umami

    2015-05-01

    Full Text Available ABSTRACTThe purpose of this study was to determine the cow’s milk powder to increased serum levels of High Density Lipoprotein (HDL of white male rat model with diabetes mellitus type 2. The design of this study was a post-test control group study conducted in 30 male rats which randomly divided into five groups. Negative control group was the group of rats which fed normally, the positive control group was induced by streptozotocin (STZ without given cow’s milk, group P1, P2, P3 were given a normal diet and cow’s milk 0.9; 1.8, and 2.7 g orally every day. The results of this study were the levels of HDL in K(-=44.22 mg/dl, K(+=47.45 mg/dl, P1=56.56 mg/dl, P2=51.82 mg/dl, and P3=59.45 mg/dl. The conclusion was the milk powder was not significantly increase levels of HDL (p>0.05. More longer intervention was suggested for further research to get more significant of HDL level on type 2 diabetes mellitus.Keywords: HDL serum level, high fat diet, milk powder, streptozotocinABSTRAKTujuan penelitian ini adalah menganalisis pengaruh pemberian susu sapi bubuk terhadap peningkatan kadar serum High Density Lipoprotein (HDL tikus putih (Rattus norvegicus berjenis kelamin jantan model diabetes melitus (DM tipe 2. Penelitian ini menggunakan desain penelitian post test control group dengan 30 ekor tikus dibagi secara acak menjadi lima kelompok. Kelompok K(- adalah tikus yang diberi pakan normal, kelompok K(+ diinduksi dengan streptozotocin (STZ tanpa diberi susu, kelompok P1 sampai P3 diberi diet normal dan susu 0,9; 1,8, dan 2,7 g secara oral setiap hari. Hasil penelitian menunjukkan kadar HDL pada K(-=44,22 mg/dl, K(+=47,45 mg/dl, P1=56,56 mg/dl, P2=51,82 mg/dl, dan P3=59,45 mg/dl. Susu sapi bubuk mampu meningkatkan kadar HDL tikus model DM tipe 2 akan tetapi tidak signifikan (p>0,05. Perlu dilakukan penelitian lebih lanjut dengan waktu lama penelitian yang berbeda sehingga bisa berdampak yang lebih signifikan untuk kadar HDL pada DM tipe 2.Kata kunci

  7. Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.

    Science.gov (United States)

    Marroquin, Elsa Y León; Herrera González, José A; Camacho López, Miguel A; Barajas, José E Villarreal; García-Garduño, Olivia A

    2016-09-08

    Radiochromic film has become an important tool to verify dose distributions for intensity-modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the formation of Newton's rings. Furthermore, the symmetrical design of EBT3 allows the user to eliminate side-orientation dependence. This film and the flatbed scanner, Epson Perfection V750, form a dosimetry system whose intrinsic characteristics were studied in this work. In addition, uncertainties associated with these intrinsic characteristics and the total uncertainty of the dosimetry system were determined. The analysis of the response of the radiochromic film (net optical density) and the fitting of the experimental data to a potential function yielded an uncertainty of 2.6%, 4.3%, and 4.1% for the red, green, and blue channels, respectively. In this work, the dosimetry system presents an uncertainty in resolving the dose of 1.8% for doses greater than 0.8 Gy and less than 6 Gy for red channel. The films irradiated between 0 and 120 Gy show differences in the response when scanned in portrait or landscape mode; less uncertainty was found when using the portrait mode. The response of the film depended on the position on the bed of the scanner, contributing an uncertainty of 2% for the red, 3% for the green, and 4.5% for the blue when placing the film around the center of the bed of scanner. Furthermore, the uniformity and reproducibility radiochromic film and reproducibility of the response of the scanner contribute less than 1% to the overall uncertainty in dose. Finally, the total dose uncertainty was 3.2%, 4.9%, and 5.2% for red, green, and blue channels, respectively. The above uncertainty values were obtained by mini-mizing the contribution to the total dose uncertainty

  8. REPRODUCIBILITY OF MACULAR PIGMENT OPTICAL DENSITY MEASUREMENT BY TWO-WAVELENGTH AUTOFLUORESCENCE IN A CLINICAL SETTING.

    Science.gov (United States)

    You, Qi Sheng; Bartsch, Dirk-Uwe G; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William R

    2016-07-01

    Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration, likely because of filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of this study is to determine the reproducibility of MPOD measurement by two-wavelength autofluorescence method using scanning laser ophthalmoscopy. Sixty-eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet age-related macular degeneration, 16 eyes with dry age-related macular degeneration, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia, and 14 eyes with tractional maculopathy, including vitreomacular traction, epiretinal membrane, or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) autofluorescence method with the Spectralis HRA + OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The analysis of variance and Bland-Altman plot were used to assess the reproducibility between the two measurements. The mean MPOD at eccentricities of 1° and 2° was 0.36 ± 0.17 (range: 0.04-0.69) and 0.15 ± 0.08 (range: -0.03 to 0.35) for the first measurement and 0.35 ± 0.17 (range: 0.02-0.68) and 0.15 ± 0.08 (range: -0.01 to 0.33) for the second measurement, respectively. The difference between the 2 measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2°, and 6° radius, and the Bland

  9. Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density

    Science.gov (United States)

    Marroquin, Elsa Y. León; Herrera González, José A.; Camacho López, Miguel A.; Barajas, José E. Villarreal

    2016-01-01

    Radiochromic film has become an important tool to verify dose distributions for intensity‐modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the formation of Newton's rings. Furthermore, the symmetrical design of EBT3 allows the user to eliminate side‐orientation dependence. This film and the flatbed scanner, Epson Perfection V750, form a dosimetry system whose intrinsic characteristics were studied in this work. In addition, uncertainties associated with these intrinsic characteristics and the total uncertainty of the dosimetry system were determined. The analysis of the response of the radiochromic film (net optical density) and the fitting of the experimental data to a potential function yielded an uncertainty of 2.6%, 4.3%, and 4.1% for the red, green, and blue channels, respectively. In this work, the dosimetry system presents an uncertainty in resolving the dose of 1.8% for doses greater than 0.8 Gy and less than 6 Gy for red channel. The films irradiated between 0 and 120 Gy show differences in the response when scanned in portrait or landscape mode; less uncertainty was found when using the portrait mode. The response of the film depended on the position on the bed of the scanner, contributing an uncertainty of 2% for the red, 3% for the green, and 4.5% for the blue when placing the film around the center of the bed of scanner. Furthermore, the uniformity and reproducibility radiochromic film and reproducibility of the response of the scanner contribute less than 1% to the overall uncertainty in dose. Finally, the total dose uncertainty was 3.2%, 4.9%, and 5.2% for red, green, and blue channels, respectively. The above uncertainty values were obtained by minimizing the contribution to the total dose

  10. [Studies on the relationship between beta-adrenergic receptor density on cell wall lymphocytes, total serum catecholamine level and heart rate in patients with hyperthyroidism].

    Science.gov (United States)

    Gajek, J; Zieba, I; Zyśko, D

    2000-08-01

    Hyperthyreosis mimics the hyperadrenergic state and its symptoms were though to be dependent on increased level of catecholamines. Another reason for the symptoms could be the increased density or affinity of beta-adrenergic receptors to catecholamines. The aim of the study was to examine the elements of sympathetic nervous system, thyroid hormones level and their influence on heart rate control in patients with hyperthyreosis. The study was carried out in 18 women, mean age 48.9 +/- 8.7 yrs and 6 men, mean age 54.2 +/- 8.7 yrs. The control group consisted of 30 healthy persons matched for age and sex. We examined the density of beta-adrenergic receptors using radioligand labelling method with 125I-cyanopindolol, serum total catecholamines level with radioenzymatic assay kit, the levels of free thyroid hormones using radioimmunoassays and thyreotropine level with immunoradiometric assay. Maximal, minimal and mean heart rate were studied using Holter monitoring system. The density of beta-adrenergic receptors in hyperthyreosis was 37.3 +/- 21.7 vs 37.2 +/- 18.1 fmol/mg in the control group (p = NS). Total catecholamines level was significantly decreased in hyperthyreosis group: 1.5 +/- 0.89 vs 1.9 +/- 0.73 pmol/ml (p < 0.05). There was significantly higher minimal, maximal and mean heart rate in hyperthyreosis group (p < 0.0001, p < 0.0001 and p < 0.05 respectively). There was a weak inverse correlation between minimum heart rate and triiodothyronine level (r = -0.38, p < 0.05). An inverse correlation between triiodothyronine and catecholamines level (r = -0.49, p < 0.05) was observed. Beta-adrenergic receptors density is unchanged and catecholamines level is decreased in hyperthyreosis when compared to normal subjects. There is no correlation between minimal heart rate and adrenergic receptors density or catecholamines level in hyperthyreosis.

  11. Evolution of the optical vortex density in phase corrected speckle fields

    CSIR Research Space (South Africa)

    Roux, FS

    2010-09-01

    Full Text Available In an attempt to understand the process whereby the phase modulation due to atmospheric turbulance causes phase singularities (also called optical vortices), the authors investigated the effect of phase perturbations in speckle beams. They perturb...

  12. Functional imaging of the human brain using a modular, fibre-less, high-density diffuse optical tomography system.

    Science.gov (United States)

    Chitnis, Danial; Cooper, Robert J; Dempsey, Laura; Powell, Samuel; Quaggia, Simone; Highton, David; Elwell, Clare; Hebden, Jeremy C; Everdell, Nicholas L

    2016-10-01

    We present the first three-dimensional, functional images of the human brain to be obtained using a fibre-less, high-density diffuse optical tomography system. Our technology consists of independent, miniaturized, silicone-encapsulated DOT modules that can be placed directly on the scalp. Four of these modules were arranged to provide up to 128, dual-wavelength measurement channels over a scalp area of approximately 60 × 65 mm 2 . Using a series of motor-cortex stimulation experiments, we demonstrate that this system can obtain high-quality, continuous-wave measurements at source-detector separations ranging from 14 to 55 mm in adults, in the presence of hair. We identify robust haemodynamic response functions in 5 out of 5 subjects, and present diffuse optical tomography images that depict functional haemodynamic responses that are well-localized in all three dimensions at both the individual and group levels. This prototype modular system paves the way for a new generation of wearable, wireless, high-density optical neuroimaging technologies.

  13. An evaluation of the subtraction photoshop software accuracy to detect minor changes in optical density by radiovisiography

    Directory of Open Access Journals (Sweden)

    Talaeipour AR.

    2004-06-01

    Full Text Available Statement of Problem: Subtraction is a newly presented radiography technique to detect minor density"nchanges that are not visible by conventional radiography."nPurpose: The aim of this In-vitro study was to evaluate the efficacy of photoshop subtraction software for"ndetecting minor density changes between two dental images."nMaterials and Methods: In this research, five dried human mandibles were held in fixed position while thin"naluminium sheets were superimposed on each mandible on the 1th and 2nd molar teeth regions."nA reference image, without aluminium sheet placement, was obtained from each mandible subsequently series"nconsist of 20 images with aluminium sheets, ranging from 50p. to "5Q0"x were recorded by radiovisiography"n(RVG system. Initial images were subtracted from subsequent ones by Photoshop subtraction software. The"ndifference in density between the two images at the 1st and 2nd molar sites was related to the aluminium"nsheets. The optical density of aluminium sheets was determined by densitometer."nResults: In the present study, 6.6% of the optical density changes of the minimum aluminium thickness as"n300u. could be detected by photoshop software software."nConclusion: The findings of this study showed that the accuracy of photoshop subtraction software was equal"nto that of the conventional subtraction softwares. Additionally, the accuracy of this software was proved to be"nsuitable for clinical investigations of small localized changes in alveolar bone.

  14. High Speed and High Spatial Density Parameter Measurement Using Fiber Optic Sensing Technology

    Science.gov (United States)

    Parker, Allen R. Jr. (Inventor); Chan, Hon Man (Inventor); Richards, William Lance (Inventor); Piazza, Anthony (Inventor); Hamory, Philip J (Inventor)

    2017-01-01

    The present invention is an improved fiber optic sensing system (FOSS) having the ability to provide both high spatial resolution and high frequency strain measurements. The inventive hybrid FOSS fiber combines sensors from high acquisition speed and low spatial resolution Wavelength-Division Multiplexing (WDM) systems and from low acquisition speed and high spatial resolution Optical Frequency Domain Reflection (OFDR) systems. Two unique light sources utilizing different wavelengths are coupled with the hybrid FOSS fiber to generate reflected data from both the WDM sensors and OFDR sensors operating on a single fiber optic cable without incurring interference from one another. The two data sets are then de-multiplexed for analysis, optionally with conventionally-available WDM and OFDR system analyzers.

  15. Electronic and optical properties of Y-doped Si{sub 3}N{sub 4} by density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhifeng [State Key Lab of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Chen, Fei, E-mail: chenfei027@gmail.com [State Key Lab of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Key Laboratory of Advanced Technology for Specially Functional Materials, Ministry of Education, Wuhan University of Technology, Wuhan 430070 (China); Su, Rui; Wang, Zhihao; Li, Junyang; Shen, Qiang [State Key Lab of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Zhang, Lianmeng [State Key Lab of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070 (China); Key Laboratory of Advanced Technology for Specially Functional Materials, Ministry of Education, Wuhan University of Technology, Wuhan 430070 (China)

    2015-07-15

    Highlights: • Y-doped α-Si{sub 3}N{sub 4} and β-Si{sub 3}N{sub 4} are systematically investigated by DFT. • Impacts of local structure and bond character on electronic property are studied. • Static dielectric constants and optical absorption properties are investigated. - Abstract: Geometry structures, formation energies, electronic and optical properties of Y-doped α-Si{sub 3}N{sub 4} and β-Si{sub 3}N{sub 4} are investigated based on the density functional theory (DFT). The low values of formation energies indicate both Y-doped Si{sub 3}N{sub 4} models can be easily synthesized. Besides, the negative formation energies of α-Y{sub i}-Si{sub 3}N{sub 4} demonstrate that interstitial Y-doped α-Si{sub 3}N{sub 4} has an excellent stability. The energies of impurity levels are different resulting from the different chemical environment around Y atoms. The impurity levels localized in the band gap reduces the maximum energy gaps, which enhances the optical properties of Si{sub 3}N{sub 4}. The static dielectric constants become larger and the optical absorption spectra show the red-shift phenomena for all Y-doped Si{sub 3}N{sub 4} models.

  16. Comparison of serum Dkk1 (Dickkopf-1) and bone mineral density in patients on bisphosphonate treatment vs no treatment.

    LENUS (Irish Health Repository)

    Memon, Adeel R

    2013-05-17

    Complex pathways affect bone metabolism at the cellular level, and a balance between osteoblast and osteoclast activity is critical to bone remodeling. One of the major pathways affecting bone metabolism is Wnt\\/β-catenin signaling, and its disturbances lead to a wide range of bone abnormalities. An important antagonist of this pathway is Dickkopf-1 (Dkk1). Higher Dkk1 levels have been associated with increased bone loss due to inhibition of Wnt pathway. Currently, bisphosphonates are the most commonly used agents to treat primary osteoporotic patients. This study demonstrates the effect of bisphosphonates on Dkk1 levels and its correlation with bone mineral density (BMD). Eighty patients with low BMD were recruited and divided into 2 groups of 40 each (bisphosphonate treatment group and control group). The mean Dkk1 level in the treatment group was significantly reduced to 2358.18 vs 3749.80 pg\\/mL in the control group (p<0.001). Pearson correlation coefficient showed negative correlation between Dkk1 and BMD at lumbar spine (r=-0.55) and femoral neck in the control group; however, no such correlation was found in the treatment group (r=-0.05). Hence, bisphosphonate therapy leads to reduction in Dkk1 levels, but it does not correlate with BMD in such patients.

  17. Energy gaps, valence and conduction charge densities and optical properties of GaAs1‑xPx

    Science.gov (United States)

    Al-Hagan, O. A.; Algarni, H.; Bouarissa, N.; Alhuwaymel, T. F.; Ajmal Khan, M.

    2018-04-01

    The electronic structure and its derived valence and conduction charge distributions along with the optical properties of zinc-blende GaAs1‑xPx ternary alloys have been studied. The calculations are performed using a pseudopotential approach under the virtual crystal approximation (VCA) which takes into account the compositional disorder effect. Our findings are found to be generally in good accord with experiment. The composition dependence of direct and indirect bandgaps showed a clear bandgap bowing. The nature of the gap is found to depend on phosphorous content. The bonding and ionicity of the material of interest have been examined in terms of the anti-symmetric gap and charge densities. The variation in the optical constants versus phosphorous concentration has been discussed. The present investigation may give a useful applications in infrared and visible spectrum light emitters.

  18. Examination of the relation between periodontal health status and cardiovascular risk factors: serum total and high density lipoprotein cholesterol, C-reactive protein, and plasma fibrinogen.

    Science.gov (United States)

    Wu, T; Trevisan, M; Genco, R J; Falkner, K L; Dorn, J P; Sempos, C T

    2000-02-01

    Using data from the Third National Health and Nutrition Examination Survey (1988-1994), the authors examined the relation between periodontal health and cardiovascular risk factors: serum total and high density lipoprotein cholesterol, C-reactive protein, and plasma fibrinogen. A total of 10,146 participants were included in the analyses of cholesterol and C-reactive protein and 4,461 in the analyses of fibrinogen. Periodontal health indicators included the gingival bleeding index, calculus index, and periodontal disease status (defined by pocket depth and attachment loss). While cholesterol and fibrinogen were analyzed as continuous variables, C-reactive protein was dichotomized into two levels. The results show a significant relation between indicators of poor periodontal status and increased C-reactive protein and fibrinogen. The association between periodontal status and total cholesterol level is much weaker. No consistent association between periodontal status and high density lipoprotein cholesterol was detectable. Similar patterns of association were observed for participants aged 17-54 years and those 55 years and older. In conclusion, this study suggests that total cholesterol, C-reactive protein, and fibrinogen are possible intermediate factors that may link periodontal disease to elevated cardiovascular risk.

  19. Thermal and optical excitation of trapped electrons in high-density polyethylene (HDPE) studied through positron annihilation

    International Nuclear Information System (INIS)

    Nahid, F.; Zhang, J.D.; Yu, T.F.; Ling, C.C.; Fung, S.; Beling, C.D.

    2011-01-01

    Positronium (Ps) formation in high-density polyethylene (HDPE) has been studied below the glass transition temperature. The formation probability increases with positron irradiation time due to an increasing number of inter-track trapped electrons becoming available for positron capture. The temperature variation of the saturated Ps level is discussed in different models. The quenching of trapped electrons by light has been studied and the optical de-trapping cross-section for different photon energies has been estimated over the visible region.

  20. Structural, electronic and optical properties of monoclinic Na2Ti3O7 from density functional theory calculations: A comparison with XRD and optical absorption measurements

    Science.gov (United States)

    Araújo-Filho, Adailton A.; Silva, Fábio L. R.; Righi, Ariete; da Silva, Mauricélio B.; Silva, Bruno P.; Caetano, Ewerton W. S.; Freire, Valder N.

    2017-06-01

    Powder samples of bulk monoclinic sodium trititanate Na2Ti3O7 were prepared carefully by solid state reaction, and its monoclinic P21/m crystal structure and morphology were characterized by X-ray powder diffraction (XRD) and scanning electron microscopy (SEM), respectively. Moreover, the sodium trititanate main energy band gap was estimated as Eg=3.51±0.01 eV employing UV-Vis spectroscopy, which is smaller than the measured 3.70 eV energy gap published previously by other authors. Aiming to achieve a better understanding of the experimental data, density functional theory (DFT) computations were performed within the local density and generalized gradient approximations (LDA and GGA, respectively) taking into account dispersion effects through the scheme of Tkatchenko and Scheffler (GGA+TS). Optimal lattice parameters, with deviations relative to measurements Δa=-0.06 Å, Δb=0.02 Å, and Δc=-0.09 Å, were obtained at the GGA level, which was then used to simulate the sodium trititanate electronic and optical properties. Indirect band transitions have led to a theoretical gap energy value of about 3.25 eV. Our results, however, differ from pioneer DFT results with respect to the specific Brillouin zone vectors for which the indirect transition with smallest energy value occurs. Effective masses for electrons and holes were also estimated along a set of directions in reciprocal space. Lastly, our calculations revealed a relatively large degree of optical isotropy for the Na2Ti3O7 optical absorption and complex dielectric function.

  1. Calculation of nucleon densities in calcium, nickel, and molybdenum isotopes on the basis of the dispersive optical model

    Science.gov (United States)

    Bespalova, O. V.; Klimochkina, A. A.

    2017-09-01

    The radial distributions of proton and neutron densities in the even-even isotopes 40-70Ca and 48-78Ni and the analogous distributions of neutron densities in the even-even isotopes 92-138Mo were calculated on the basis of the mean-fieldmodel involving a dispersive optical potential. The respective root-mean-square radii and neutron-skin thicknesses were determined for the nuclei under study. In N > 40 calcium isotopes, the calculated neutron root-mean-square radius exhibits a fast growth with increasing N, and this is consistent with the prediction of the neutron-halo structure in calcium isotopes near the neutron drip line.

  2. The effect of serum vitamin D level and bone mineral density on balance and the risk of falling in postmenopausal women

    Directory of Open Access Journals (Sweden)

    Ayşegül Küçükali Türkyılmaz

    2013-01-01

    Full Text Available Objective: The aim of this study was to investigate the effect of bone mineral density and vitamin D level on the risk of falling and balance in postmenopausal women.Methods: The age ranged from 44 to 67 (57.25±7.27 years, 133 postmenopausal women were enrolled. Age, height, weight, socio-demographic information, history of falling and fracture in last year, risk factors for osteoporosis, and menopause duration were recorded. Serum 25OHD3 level and bone mineral density (BMD of participants were measured. Postural balance function and the risk of falling were evaluated by time-up and go test (TUG, and Berg balance scale (BBS. Patients were divided into 4 groups; group 1: low vitamin D and osteoporosis, group 2: only low vitamin D, group 3: only osteoporotic, group 4: normal. Results: There was significant difference between the groups according to TUG (p<0.001. There were significant differences between group 1 and 2, group 1 and 4, group 3 and 4 (each, p= 0.001. There was significant difference between the groups according to BBS (p<0.001. Significant differences were found between group 1 and 2, group 1 and 4, group 2 (each, p<0.001 and 3 (p= 0.002, group 3 and 4 (p<0.001. There were negative correlations between TUG, L1-L4 and femoral neck BMD (r=-0.488, p<0.001 and r =-0.462, p<0.001, respectively. There were positive correlations between BBS, L1-L4 and femoral neck BMD (r=-0.488, p<0.001 and r=-0.462, p<0.001, respectively. Conclusion: We concluded that whereas vitamin D level had no effect on balance and the risk of falling, whereas osteoporosis had effects both on balance and risk of falling. Key words: Vitamin D, bone mineral density, balance, risk of falling

  3. Polymorphisms in the ghrelin gene are associated with serum high-density lipoprotein cholesterol level and not with type 2 diabetes mellitus in Koreans.

    Science.gov (United States)

    Choi, Hyung Jin; Cho, Young Min; Moon, Min Kyong; Choi, Hye Hun; Shin, Hyoung Doo; Jang, Hak Chul; Kim, Seong Yeon; Lee, Hong Kyu; Park, Kyong Soo

    2006-11-01

    Ghrelin is known to play a role in glucose metabolism and in beta-cell function. There are controversies regarding the role of ghrelin polymorphisms in diabetes and diabetes-related phenotypes. The objective of this study was to examine polymorphisms of the ghrelin gene in a Korean cohort and investigate associations between them and susceptibility to type 2 diabetes and its related phenotypes. The ghrelin gene was sequenced to identify polymorphisms in 24 DNA samples. Common variants were then genotyped in 760 type 2 diabetic patients and 641 nondiabetic subjects. Genetic associations with diabetes-related phenotypes were also analyzed. Nine polymorphisms were identified, and four common polymorphisms [g.-1500C>G, g.-1062G > C, g.-994C > T, g.+408C > A (Leu72Met)] were genotyped in a larger study. The genotype distributions of these four common polymorphisms in type 2 diabetes patients were similar to those of normal nondiabetic controls. However, these four common polymorphisms were variably associated with several diabetes-related phenotypes, such as high-density lipoprotein (HDL) cholesterol, fasting plasma glucose, and homeostasis model assessment of insulin resistance. In particular, subjects harboring g.-1062C were associated with a lower serum HDL cholesterol level after adjusting for other variables (P = 0.0004 or 0.01 after Bonferroni correction for 24 tests). The aforementioned four common polymorphisms in the ghrelin gene were not found to be significantly associated with susceptibility to type 2 diabetes mellitus in the Korean population. However, the common polymorphism g.-1062G > C in the promoter region of the ghrelin gene was found to be significantly associated with serum HDL cholesterol levels.

  4. Quasistatic thermal and nonlinear processes of photoconversion of high-density optical radiation by multilayer structures

    Directory of Open Access Journals (Sweden)

    Blank Arkadiy

    2017-01-01

    Full Text Available The results of the systematic experimental analysis of the thermal nonlinear electro-optic properties of photoelectric converters with silicon vertical cells in comparison with solar elements and elements on the basis of In/Ga/As are presented. The parameters of the linear and quadratic approximations for the investigated dependences are determined, that allows constructing a scalable analytic model of the converter with a given type of the working elements switching.

  5. Silicon photonics integrated circuits: a manufacturing platform for high density, low power optical I/O's.

    Science.gov (United States)

    Absil, Philippe P; Verheyen, Peter; De Heyn, Peter; Pantouvaki, Marianna; Lepage, Guy; De Coster, Jeroen; Van Campenhout, Joris

    2015-04-06

    Silicon photonics integrated circuits are considered to enable future computing systems with optical input-outputs co-packaged with CMOS chips to circumvent the limitations of electrical interfaces. In this paper we present the recent progress made to enable dense multiplexing by exploiting the integration advantage of silicon photonics integrated circuits. We also discuss the manufacturability of such circuits, a key factor for a wide adoption of this technology.

  6. Optical spectroscopy of the density of gap states in ETP-deposited a-Si:H

    NARCIS (Netherlands)

    Willekens, J.; Brinza, M.; Güngör, T.; Adriaenssens, G.J.; Nesladek, M.; Kessels, W.M.M.; Smets, A.H.M.; Sanden, van de M.C.M.

    2004-01-01

    The distribution and density of localized states in the band gap of hydrogenated amorphous silicon, as deposited by the expanding thermal plasma technique, were studied by means of a combined use of the constant photocurrent method (CPM), photothermal deflection spectroscopy (PDS) and time-of-flight

  7. Quantifying protein densities on cell membranes using super-resolution optical fluctuation imaging

    Czech Academy of Sciences Publication Activity Database

    Lukeš, T.; Glatzová, Daniela; Kvíčalová, Zuzana; Levet, F.; Benda, Aleš; Letschert, S.; Sauer, M.; Brdička, Tomáš; Lasser, T.; Cebecauer, Marek

    2017-01-01

    Roč. 8, č. 1 (2017), č. článku 1731. ISSN 2041-1723 R&D Projects: GA ČR GA15-06989S Institutional support: RVO:61388955 ; RVO:68378050 Keywords : quantifying protein densities * membranes * single-molecule localization microscopy Subject RIV: CE - Biochemistry OBOR OECD: Biochemistry and molecular biology Impact factor: 12.124, year: 2016

  8. Acridine orange as an alternative to optical density to study growth kinetics of Lactobacillus bulgaricus ATCC 7517.

    Science.gov (United States)

    Pak, Dolar; Koo, Ok Kyung; Story, Robert S; O'Bryan, Corliss A; Crandall, Philip G; Lee, Sun-Ok; Ricke, Steven C

    2013-01-01

    In this study we assessed the use of acridine orange as an alternative to optical density to quantify the growth of Lactobacillus bulgaricus ATCC 7517. The growth of bacteria in Lactobacillus de Man Rogosa Sharpe (MRS) medium was measured by both acridine orange (AO) and optical density (OD) measurements for 24 h. The relationship between both methods was compared via correlation analysis. The doubling time of bacteria based on the values of OD600 and AO obtained during 24 h growth were also calculated. The result shows strong correlation of cell growth between OD600 and AO during the first 10 hours of growth, but the correlation was less strong when analyzing the data from 0 to 24 hours. Growth rates, generation time and lag time were also similar. This study indicates that AO could be used in place of OD to prepare growth curves of Lactobacillus bulgaricus during the exponential phase of growth, and to compare growth rates, generation times or lag times.

  9. VARIABILITY IN FOVEAL AVASCULAR ZONE AND CAPILLARY DENSITY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY MACHINES IN HEALTHY EYES.

    Science.gov (United States)

    Magrath, George N; Say, Emil Anthony T; Sioufi, Kareem; Ferenczy, Sandor; Samara, Wasim A; Shields, Carol L

    2017-11-01

    To evaluate the variability in foveal avascular zone (FAZ) and capillary density measurements on optical coherence tomography angiography using Optovue RTVue XR Avanti (OA) (Optovue) and Zeiss Cirrus HD-OCT 5000 (ZC) (Carl Zeiss Meditec). In this prospective, comparative case series, parafoveal (3 × 3 mm) optical coherence tomography angiography scans were obtained on healthy volunteers using both the Avanti and Cirrus. The FAZ area and capillary density at the level of both the superficial and deep capillary plexus were measured automatically using the built-in ReVue software (Optovue) with the Avanti as well as manually using ImageJ (National Institutes of Health) with both machines. There were 50 eyes in 25 healthy volunteers included in the analysis. Mean subject age was 33 years and there were 14 women (56%). On optical coherence tomography, mean central macular thickness was significantly greater on OA (259.1 μm) than ZC (257.6 μm, P = 0.0228). On optical coherence tomography angiography, mean superficial and deep plexus FAZ measured 0.2855 mm and 0.3465 mm on Avanti automated (A-A), 0.2739 mm and 0.3637 mm on Avanti manual (A-M), and 0.2657 mm and 0.3993 mm on Cirrus manual (C-M), respectively. There were no statistically significant differences in superficial plexus FAZ measurements between the A-A and A-M (P = 0.4019) or A-A and C-M (P = 0.1336). The A-M measured significantly larger than C-M (P = 0.0396). Deep plexus FAZ measurements were similar on A-A and A-M (P = 0.6299), but both were significantly less compared with C-M (P machine and technique are consistent and reliable between fellow eyes, significant variability exists in FAZ and capillary density measurements among different machines and techniques. Comparison of measurements across machines and techniques should be considered with caution.

  10. Quantitative assessment of slit Mura defect in a thin film transistor-liquid crystal display based on chromaticity and optical density

    International Nuclear Information System (INIS)

    Tzu, Fu-Ming; Chou, Jung-Hua

    2010-01-01

    An innovative non-contact optical inspection method is developed to quantify slit Mura defects for thin film transistor–liquid crystal displays (TFT-LCDs). From the measurements of both chromaticity and optical densities across the slit Mura, the results indicate that the optical density profile is a concave shape and the chromaticity distribution is a convex shape. A linear relation with a negative slope exists between the chromaticity and optical density. A larger colour difference has a steeper slope, and vice versa. All of the measurements with uncertainties of a 99.7% confidence interval satisfy the requirements of the flat panel display industry. The proposed method can accurately quantify the pattern of blue slit Mura of TFT-LCDs; even the perceptibility is below the just noticeable difference

  11. Effect of Current Density on Optical Properties of Anisotropic Photoelectrochemical Etched Silicon (110)

    Science.gov (United States)

    Amirhoseiny, M.; Hassan, Z.; Ng, S. S.

    2012-08-01

    Photoelectrochemical etched Si layers were prepared on n-type (110) oriented silicon wafer. The photoluminescence (PL), Fourier transformed infrared (FTIR) absorption and Raman spectroscopies of etched Si (110) at two different current densities were studied. Both samples showed PL peak in the visible spectral range situated from 650 nm to 750 nm. The corresponding changes in Raman spectra at different current density are discussed. The blue shift in the PL and Raman peaks is consequent of the quantum confinement effect and defect states of surface Si nanocrystallites complexes and hydrogen atoms of the photoelectrochemical etched Si (110) samples. The attenuated total reflection (ATR) results show both hydrogen and oxygen related IR modes in the samples which can be used to explain the PL effect.

  12. Rheo-optical Raman study of microscopic deformation in high-density polyethylene under hot drawing

    OpenAIRE

    Kida, Takumitsu; Hiejima, Yusuke; Nitta, Koh-hei

    2015-01-01

    In situ observation of the microscopic structural changes in high-density polyethylene during hot drawing was performed by incorporating a temperature-controlled tensile machine into a Raman spectroscopy apparatus. It was found that the load sharing and molecular orientation during elongation drastically changed at 50°C. The microscopic stress of the crystalline chains decreased with increasing temperature and diminished around 50°C. Moreover, the orientation of the crystalline chains was gre...

  13. Morphological and Optical Characterization of High Density Au/PAA Nanoarrays

    Directory of Open Access Journals (Sweden)

    Mohamed Shaban

    2016-01-01

    Full Text Available Hexagonal nanoarrays of Au nanorods and nanopillar were deposited on nanoporous anodic alumina (PAA membranes utilizing dc electrodeposition. The surface morphologies and optical properties were characterized by using field emission-scanning electron microscopy (FE-SEM and UV-Vis spectrophotometer, respectively. The optical reflectance spectra of the as-prepared, pore widened, and 2D-Au nanorods-coated PAA membranes were studied in detail. The effects of the angle of incident, pore widening time, and electrodeposition time on the characteristic peaks positions and intensities of the fabricated nanoarrays were addressed. As the angle of incident increased, the interference peaks and transverse surface resonance are shifted to longer wavelengths, but the longitudinal surface plasmon resonance is shifted to shorter wavelengths. Also, the reflected intensities are decreased linearly for the as-prepared sample and decreased exponentially for Au/PAA samples. Using the modified Kubelka-Munk radiative transfer model, the energy gap is increased from 2.83 to 3.06 eV and the refractive index is decreased from 1.84 to 1.36 for the as-prepared and 70 min pore widened PAA membranes, respectively. Based on the advantages of the fabrication approach and the enhanced and controlled properties, this generation of Au/PAA arrays can be used as efficient building blocks for nanoelectronics and nanophotonic devices.

  14. Determination of bone mineral density of the distal extremity of the radio in Rottweiller, by radiographic optic densitometry

    International Nuclear Information System (INIS)

    Alves, Jefferson Douglas Soares; Sterman, Franklin de Almeida

    2010-01-01

    This study allowed the standardization of the bone mineral density (BMD) of the distal extremity of the radio of 36 dogs adults in Rottweiler breed by radiographic optic densitometry. The limbs of the animals were radiographed with scale of aluminum that served as a reference. The radiographs images were digitalized and analyzed by a computer program for comparison of gray tones between the standard image and the image of the reference scale radiographed with the bone. Afterwards the values of density were expressed in millimeters of aluminum. Also studied the correlations between BMD and the sex, weight and external measures as the length of spine, height of the animal and circumference the distal extremity of the limb in study. The mean values and standard deviations of the bone mineral density of the distal extremity of the radio were: for the metaphyseal region the average of BMD of 7,88±0,89 mmAl, the diaphyseal region 1 the average of BMD of 8,58±0,80 mmAl and for diaphyseal region 2 of BMD of 9,00±0,74 mmAl. (author)

  15. Density functional theory versus quantum Monte Carlo simulations of Fermi gases in the optical-lattice arena★

    Science.gov (United States)

    Pilati, Sebastiano; Zintchenko, Ilia; Troyer, Matthias; Ancilotto, Francesco

    2018-04-01

    We benchmark the ground state energies and the density profiles of atomic repulsive Fermi gases in optical lattices (OLs) computed via density functional theory (DFT) against the results of diffusion Monte Carlo (DMC) simulations. The main focus is on a half-filled one-dimensional OLs, for which the DMC simulations performed within the fixed-node approach provide unbiased results. This allows us to demonstrate that the local spin-density approximation (LSDA) to the exchange-correlation functional of DFT is very accurate in the weak and intermediate interactions regime, and also to underline its limitations close to the strongly-interacting Tonks-Girardeau limit and in very deep OLs. We also consider a three-dimensional OL at quarter filling, showing also in this case the high accuracy of the LSDA in the moderate interaction regime. The one-dimensional data provided in this study may represent a useful benchmark to further develop DFT methods beyond the LSDA and they will hopefully motivate experimental studies to accurately measure the equation of state of Fermi gases in higher-dimensional geometries. Supplementary material in the form of one pdf file available from the Journal web page at http://https://doi.org/10.1140/epjb/e2018-90021-1.

  16. Corneal Dendritic Cell Density Is Associated with Subbasal Nerve Plexus Features, Ocular Surface Disease Index, and Serum Vitamin D in Evaporative Dry Eye Disease

    Directory of Open Access Journals (Sweden)

    Rohit Shetty

    2016-01-01

    Full Text Available Dry eye disease (DED has evolved into a major public health concern with ocular discomfort and pain being responsible for significant morbidity associated with DED. However, the etiopathological factors contributing to ocular pain associated with DED are not well understood. The current IVCM based study investigated the association between corneal dendritic cell density (DCD, corneal subbasal nerve plexus (SBNP features, and serum vitamin D and symptoms of evaporative dry eye (EDE. The study included age and sex matched 52 EDE patients and 43 heathy controls. A significant increase in the OSDI scores (discomfort subscale was observed between EDE (median, 20.8 and control (median, 4.2 cohorts (P23 (P<0.05. A positive correlation was observed between DCD and OSDI discomfort subscale (r=0.348; P<0.0003 and SBNP features. An inverse correlation was observed between vitamin D and OSDI scores (r=-0.332; P=0.0095 and DCD with dendritic processes (r=-0.322; P=0.0122. The findings implicate DCD, SBNP features, and vitamin D with EDE symptoms.

  17. Vibrational Spectra and Density functional calculation of Organic Nonlinear Optic Crystal p-Amino Acetanilide

    Energy Technology Data Exchange (ETDEWEB)

    Saja, D; Joe, I Hubert; Jayakumar, V S [Department of Physics, Mar Ivanios College, Thiruvananthapuram-695015, Kerala (India)

    2006-01-01

    The NIR-FT Raman, FT-IR spectral analysis of potential NLO material P-Amino Acetanilide is carried out by density functional computations. The optimized geometry shows that NH2 and NHCOCH3 groups substituted in para position of phenyl ring are non-planar which predicts maximum conjugation of molecule with donor and acceptor groups. Vibrational analysis reveals that simultaneous IR and Raman activation of the phenyl ring modes also provide evidence for the charge transfer interaction between the donors and the acceptor can make the molecule highly polarized and the intra molecular charge transfer interaction must be responsible for the NLO properties of PAA.

  18. Vibrational Spectra and Density functional calculation of Organic Nonlinear Optic Crystal p-Amino Acetanilide

    International Nuclear Information System (INIS)

    Saja, D; Joe, I Hubert; Jayakumar, V S

    2006-01-01

    The NIR-FT Raman, FT-IR spectral analysis of potential NLO material P-Amino Acetanilide is carried out by density functional computations. The optimized geometry shows that NH2 and NHCOCH3 groups substituted in para position of phenyl ring are non-planar which predicts maximum conjugation of molecule with donor and acceptor groups. Vibrational analysis reveals that simultaneous IR and Raman activation of the phenyl ring modes also provide evidence for the charge transfer interaction between the donors and the acceptor can make the molecule highly polarized and the intra molecular charge transfer interaction must be responsible for the NLO properties of PAA

  19. Structural, electronic and optical properties of monoclinic Na2Ti3O7 from density functional theory calculations: A comparison with XRD and optical absorption measurements

    International Nuclear Information System (INIS)

    Araújo-Filho, Adailton A.; Silva, Fábio L.R.; Righi, Ariete; Silva, Mauricélio B. da; Silva, Bruno P.; Caetano, Ewerton W.S.; Freire, Valder N.

    2017-01-01

    Powder samples of bulk monoclinic sodium trititanate Na 2 Ti 3 O 7 were prepared carefully by solid state reaction, and its monoclinic P2 1 /m crystal structure and morphology were characterized by X-ray powder diffraction (XRD) and scanning electron microscopy (SEM), respectively. Moreover, the sodium trititanate main energy band gap was estimated as E g =3.51±0.01 eV employing UV–Vis spectroscopy, which is smaller than the measured 3.70 eV energy gap published previously by other authors. Aiming to achieve a better understanding of the experimental data, density functional theory (DFT) computations were performed within the local density and generalized gradient approximations (LDA and GGA, respectively) taking into account dispersion effects through the scheme of Tkatchenko and Scheffler (GGA+TS). Optimal lattice parameters, with deviations relative to measurements Δa=−0.06 Å, Δb=0.02 Å, and Δc=−0.09 Å, were obtained at the GGA level, which was then used to simulate the sodium trititanate electronic and optical properties. Indirect band transitions have led to a theoretical gap energy value of about 3.25 eV. Our results, however, differ from pioneer DFT results with respect to the specific Brillouin zone vectors for which the indirect transition with smallest energy value occurs. Effective masses for electrons and holes were also estimated along a set of directions in reciprocal space. Lastly, our calculations revealed a relatively large degree of optical isotropy for the Na 2 Ti 3 O 7 optical absorption and complex dielectric function. - Graphical abstract: Monoclinic sodium trititanate Na2Ti3O7 was characterized by experiment and dispersion-corrected DFT calculations. An indirect gap of 3.5 eV is predicted, with heavy electrons and anisotropic holes ruling its conductivity. - Highlights: • Monoclinic Na2Ti3O7 was characterized by experiment (XRD, SEM, UV–Vis spectroscopy). • DFT GGA+TS optimized geometry and optoelectronic properties were

  20. Structure and representation of correlation functions and the density matrix for a statistical wave field in optics

    International Nuclear Information System (INIS)

    Sudarshan, E.C.G.; Mukunda, N.

    1978-03-01

    A systematic structure analysis of the correlation functions of statistical quantum optics is carried out. From a suitably defined auxiliary two-point function identification of the excited modes in the wave field is found. The relative simplicity of the higher order correlation functions emerges as a by-product and the conditions under which these are made pure are derived. These results depend in a crucial manner on the notion of coherence indices aand of unimodular coherence indices. A new class of approximate expressions for the density operator of a statistical wave field is worked out based on discrete characteristic sets. These are even more economical than the diagonal coherent state representations. An appreciation of the subtleties of quantum theory obtains. Certain implications for the physics of light beams are cited. 28 references

  1. Spectroscopic investigations using density functional theory on 2-methoxy- 4(phenyliminomethyl)phenol: A non linear optical material

    Science.gov (United States)

    Hijas, K. M.; Madan Kumar, S.; Byrappa, K.; Geethakrishnan, T.; Jeyaram, S.; Nagalakshmi, R.

    2018-03-01

    Single crystals of 2-methoxy-4(phenyliminomethyl)phenol were grown from ethanol by slow evaporation solution growth technique. Single crystal X-ray diffraction experiment reveals the crystallization in orthorhombic system having non-centrosymmetric space group C2221. Geometrical optimization by density functional theory method was carried out using Gaussian program and compared with experimental results. Detailed experimental and theoretical vibrational analyses were carried out and the results were correlated to find close agreement. Thermal analyses show the material is thermally stable with a melting point of 159 °C. Natural bond orbital analysis was carried out to explain charge transfer interactions through hydrogen bonding. Relatively smaller HOMO-LUMO band gap favors the non linear optical activity of the molecule. Natural population analysis and molecular electrostatic potential calculations visualize the charge distribution in an isolated molecule. Calculated first-order molecular hyperpolarizability and preliminary second harmonic generation test carried out using Kurtz-Perry technique establish 2-methoxy-4(phenyliminomethyl)phenol crystal as a good non linear optical material. Z-scan proposes the material for reverse saturable absorption.

  2. Electronic and optical properties of families of polycyclic aromatic hydrocarbons: A systematic (time-dependent) density functional theory study

    International Nuclear Information System (INIS)

    Malloci, G.; Cappellini, G.; Mulas, G.; Mattoni, A.

    2011-01-01

    Graphical abstract: Electronic absorption spectra of the neutral molecules of the four PAH classes considered, as computed using the real-time real-space TD-DFT. Highlights: →We present a systematic comparative study of families of PAHs. → We computed electronic, optical, and transport properties as a function of size. → We considered oligoacenes, phenacenes, circumacenes, and oligorylenes. → Circumacenes have the best transport properties compared to the other classes. → Oligorylenes are much more efficient in absorbing low-energy photons. - Abstract: Homologous classes of polycyclic aromatic hydrocarbons (PAHs) in their crystalline state are among the most promising materials for organic opto-electronics. Following previous works on oligoacenes we present a systematic comparative study of the electronic, optical, and transport properties of oligoacenes, phenacenes, circumacenes, and oligorylenes. Using density functional theory (DFT) and time-dependent DFT we computed: (i) electron affinities and first ionization energies; (ii) quasiparticle correction to the highest occupied molecular orbital (HOMO)-lowest unoccupied molecular orbital (LUMO) gap; (iii) molecular reorganization energies and (iv) electronic absorption spectra of neutral and ±1 charged systems. The excitonic effects are estimated by comparing the optical gap and the quasiparticle corrected HOMO-LUMO energy gap. For each molecular property computed, general trends as a function of molecular size and charge state are discussed. Overall, we find that circumacenes have the best transport properties, displaying a steeper decrease of the molecular reorganization energy at increasing sizes, while oligorylenes are much more efficient in absorbing low-energy photons in comparison to the other classes.

  3. Optical sensor system for time-resolved quantification of methane densities in CH4-fueled spark ignition engines.

    Science.gov (United States)

    Golibrzuch, Kai; Digulla, Finn-Erik; Bauke, Stephan; Wackerbarth, Hainer; Thiele, Olaf; Berg, Thomas

    2017-08-01

    We present the development and the first application of an optical sensor system that allows single-cycle determination of methane (CH 4 ) concentration inside internal combustion (IC) engines. We use non-dispersive infrared absorption spectroscopy to detect the CH 4 density with a time resolution up to 33 μs at acquisition rates of 30 kHz. The measurement scheme takes advantage of the strong temperature dependence of the absorption band applying two detection channels for CH 4 that detect different spectral regions of the ν 3 anti-symmetric C-H-stretch absorption. The strategy allows the simultaneous determination of fuel concentration as well as gas temperature. We show the proof-of-concept by validation of the measurement strategy in static pressure cell experiments as well as its application to a methane-fueled IC engine using a modified spark plug probe. Our results clearly demonstrate that it is crucial to determine the CH 4 temperature in the probe volume. Due to thermal influences of the sensor probe, the temperature needed to calculate the desired quantities (fuel density, fuel concentration) significantly differs from the gas phase temperature in the rest of the combustion chamber and estimations from standard thermodynamic models, e.g., polytropic compression, will fail.

  4. Measuring and engineering the atomic mass density wave of a Gaussian mass-polariton pulse in optical fibers

    Science.gov (United States)

    Partanen, Mikko; Tulkki, Jukka

    2018-02-01

    Conventional theories of electromagnetic waves in a medium assume that only the energy of the field propagates inside the medium. Consequently, they neglect the transport of mass density by the medium atoms. We have recently presented foundations of a covariant theory of light propagation in a nondispersive medium by considering a light wave simultaneously with the dynamics of the medium atoms driven by optoelastic forces [Phys. Rev. A 95, 063850 (2017)]. In particular, we have shown that the mass is transferred by an atomic mass density wave (MDW), which gives rise to mass-polariton (MP) quasiparticles, i.e., covariant coupled states of the field and matter having a nonzero rest mass. Another key observation of the mass-polariton theory of light is that, in common semiconductors, most of the momentum of light is transferred by moving atoms, e.g., 92% in the case of silicon. In this work, we generalize the MP theory of light for dispersive media and consider experimental measurement of the mass transferred by the MDW atoms when an intense light pulse propagates in a silicon fiber. In particular, we consider optimal intensity and time dependence of a Gaussian pulse and account for the breakdown threshold irradiance of the material. The optical shock wave property of the MDW, which propagates with the velocity of light instead of the velocity of sound, prompts for engineering of novel device concepts like very high frequency mechanical oscillators not limited by the acoustic cutoff frequency.

  5. Density wave induced star formation: The optical surface brightness of galaxies

    International Nuclear Information System (INIS)

    Bash, F.N.

    1979-01-01

    A model for the galactic orbits of molecular clouds has been devised. The molecular clouds are assumed to be launched from the two-armed spiral-shock wave, to orbit in the Galaxy like ballistic particles with gravitational perturbations due to the density-wave spiral-potential, and each cloud is assumed to produce a cluster of stars. Each cloud radiates detectable 12 C 16 O (J=0→1) spectral line radiation from birth for 40 million years. Stars are seen in the cloud about 25 million years after birth, and the star cluster is assumed to continue in ballistic orbit around the Galaxy.The model has been tested by comparing its predicted velocity-longitude diagram for CO against that observed for the Galaxy and by comparing the model's predicted distribution of light in the UBV photometric bands against observed surface photometry for Sb and SC galaxies. The interpolation of the initial velocities in the model was corrected, and the model was examined to see whether preshock or postshock initial velocities better fit the observations. The model gives very good general agreement and reproduces many of the features observed in the CO velocity-longitude diagram

  6. A role for the high-density lipoprotein receptor SR-B1 in synovial inflammation via serum amyloid-A.

    LENUS (Irish Health Repository)

    Mullan, Ronan Hugh

    2012-02-01

    Acute phase apoprotein Serum Amyloid A (A-SAA), which is strongly expressed in rheumatoid arthritis synovial membrane (RA SM), induces angiogenesis, adhesion molecule expression, and matrix metalloproteinase production through the G-coupled receptor FPRL-1. Here we report alternative signaling through the high-density lipoprotein receptor scavenger receptor-class B type 1 (SR-B1). Quantitative expression\\/localization of SR-B1 in RA SM, RA fibroblast-like cells (FLCs), and microvascular endothelial cells (ECs) was assessed by Western blotting and immunohistology\\/fluorescence. A-SAA-mediated effects were examined using a specific antibody against SR-B1 or amphipathic alpha-Helical Peptides (the SR-B1 antagonists L-37pA and D-37pA), in RA FLCs and ECs. Adhesion molecule expression and cytokine production were quantified using flow cytometry and ELISA. SR-B1 was strongly expressed in the RA SM lining layer and endothelial\\/perivascular regions compared with osteoarthritis SM or normal control synovium. Differential SR-B1 expression in RA FLC lines (n = 5) and ECs correlated closely with A-SAA, but not tumor necrosis factor alpha-induced intercellular adhesion molecule-1 upregulation. A-SAA-induced interleukin-6 and -8 production was inhibited in the presence of anti-SR-B1 in human microvascular endothelial cells and RA FLCs. Moreover, D-37pA and L-37pA inhibited A-SAA-induced vascular cell adhesion molecule-1 and intercellular adhesion molecule expression from ECs in a dose-dependent manner. As SR-B1 is expressed in RA synovial tissue and mediates A-SAA-induced pro-inflammatory pathways, a better understanding of A-SAA-mediated inflammatory pathways may lead to novel treatment strategies for RA.

  7. Preparation of Curcumin-Piperazine Coamorphous Phase and Fluorescence Spectroscopic and Density Functional Theory Simulation Studies on the Interaction with Bovine Serum Albumin.

    Science.gov (United States)

    Pang, Wenzhe; Lv, Jie; Du, Shuang; Wang, Jiaojiao; Wang, Jing; Zeng, Yanli

    2017-09-05

    In the present study, a new coamorphous phase (CAP) of bioactive herbal ingredient curcumin (CUR) with high solubilitythe was screened with pharmaceutically acceptable coformers. Besides, to provide basic information for the best practice of physiological and pharmaceutical preparations of CUR-based CAP, the interaction between CUR-based CAP and bovine serum albumin (BSA) was studied at the molecular level in this paper. CAP of CUR and piperazine with molar ratio of 1:2 was prepared by EtOH-assisted grinding. The as-prepared CAP was characterized by powder X-ray diffraction, modulated temperature differential scanning calorimetry, thermogravimetric analysis, Fourier-transform infrared, and solid-state 13 C nuclear magnetic resonance. The 1:2 CAP stoichioimetry was sustained by C═O···H hydrogen bonds between the N-H group of the piperazine and the C═O group of CUR; piperazine stabilized the diketo structure of CUR in CAP. The dissolution rate of CUR-piperazine CAP in 30% ethanol-water was faster than that of CUR; the t 50 values were 243.1 min for CUR and 4.378 min for CAP. Furthermore, interactions of CUR and CUR-piperazine CAP with BSA were investigated by fluorescence spectroscopy and density functional theory (DFT) calculation. The binding constants (K b ) of CUR and CUR-piperazine CAP with BSA were 10.0 and 9.1 × 10 3 L mol -1 at 298 K, respectively. Moreover, DFT simulation indicated that the interaction energy values of hydrogen-bonded interaction in the tryptophan-CUR and tryptophan-CUR-piperazine complex were -26.1 and -17.9 kJ mol -1 , respectively. In a conclusion, after formation of CUR-piperazine CAP, the interaction forces between CUR and BSA became weaker.

  8. Pengaruh Berbagai Dosis Jus Buah Sirsak (Annona muricata L. Terhadap Penurunan Kadar Kolesterol Low Density Lipoprotein (LDL Serum Tikus Putih (Rattus norvegicus Dislipidemia

    Directory of Open Access Journals (Sweden)

    Hesti Dwi Tia

    2014-09-01

    There was the effect of various doses of soursop juice to decrease LDL’s cholesterol levels in dyslipidemia white rat serum. The greater the dose of soursop juice given, the greater the reduction in LDL’s cholesterol levels in the serum of dyslipidemia white rat.

  9. L-Asparagine crystals with wide gap semiconductor features: optical absorption measurements and density functional theory computations.

    Science.gov (United States)

    Zanatta, G; Gottfried, C; Silva, A M; Caetano, E W S; Sales, F A M; Freire, V N

    2014-03-28

    Results of optical absorption measurements are presented together with calculated structural, electronic, and optical properties for the anhydrous monoclinic L-asparagine crystal. Density functional theory (DFT) within the generalized gradient approximation (GGA) including dispersion effects (TS, Grimme) was employed to perform the calculations. The optical absorption measurements revealed that the anhydrous monoclinic L-asparagine crystal is a wide band gap material with 4.95 eV main gap energy. DFT-GGA+TS simulations, on the other hand, produced structural parameters in very good agreement with X-ray data. The lattice parameter differences Δa, Δb, Δc between theory and experiment were as small as 0.020, 0.051, and 0.022 Å, respectively. The calculated band gap energy is smaller than the experimental data by about 15%, with a 4.23 eV indirect band gap corresponding to Z → Γ and Z → β transitions. Three other indirect band gaps of 4.30 eV, 4.32 eV, and 4.36 eV are assigned to α3 → Γ, α1 → Γ, and α2 → Γ transitions, respectively. Δ-sol computations, on the other hand, predict a main band gap of 5.00 eV, just 50 meV above the experimental value. Electronic wavefunctions mainly originating from O 2p-carboxyl, C 2p-side chain, and C 2p-carboxyl orbitals contribute most significantly to the highest valence and lowest conduction energy bands, respectively. By varying the lattice parameters from their converged equilibrium values, we show that the unit cell is less stiff along the b direction than for the a and c directions. Effective mass calculations suggest that hole transport behavior is more anisotropic than electron transport, but the mass values allow for some charge mobility except along a direction perpendicular to the molecular layers of L-asparagine which form the crystal, so anhydrous monoclinic L-asparagine crystals could behave as wide gap semiconductors. Finally, the calculations point to a high degree of optical

  10. L-asparagine crystals with wide gap semiconductor features: Optical absorption measurements and density functional theory computations

    Energy Technology Data Exchange (ETDEWEB)

    Zanatta, G.; Gottfried, C. [Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, 90035-003 Porto Alegre-RS (Brazil); Silva, A. M. [Universidade Estadual do Piauí, 64260-000 Piripiri-Pi (Brazil); Caetano, E. W. S., E-mail: ewcaetano@gmail.com [Instituto de Educação, Ciência e Tecnologia do Ceará, 60040-531 Fortaleza-CE (Brazil); Sales, F. A. M.; Freire, V. N. [Departamento de Física, Universidade Federal do Ceará, Caixa Postal 6030, 60455-760 Fortaleza-CE (Brazil)

    2014-03-28

    Results of optical absorption measurements are presented together with calculated structural, electronic, and optical properties for the anhydrous monoclinic L-asparagine crystal. Density functional theory (DFT) within the generalized gradient approximation (GGA) including dispersion effects (TS, Grimme) was employed to perform the calculations. The optical absorption measurements revealed that the anhydrous monoclinic L-asparagine crystal is a wide band gap material with 4.95 eV main gap energy. DFT-GGA+TS simulations, on the other hand, produced structural parameters in very good agreement with X-ray data. The lattice parameter differences Δa, Δb, Δc between theory and experiment were as small as 0.020, 0.051, and 0.022 Å, respectively. The calculated band gap energy is smaller than the experimental data by about 15%, with a 4.23 eV indirect band gap corresponding to Z → Γ and Z → β transitions. Three other indirect band gaps of 4.30 eV, 4.32 eV, and 4.36 eV are assigned to α3 → Γ, α1 → Γ, and α2 → Γ transitions, respectively. Δ-sol computations, on the other hand, predict a main band gap of 5.00 eV, just 50 meV above the experimental value. Electronic wavefunctions mainly originating from O 2p–carboxyl, C 2p–side chain, and C 2p–carboxyl orbitals contribute most significantly to the highest valence and lowest conduction energy bands, respectively. By varying the lattice parameters from their converged equilibrium values, we show that the unit cell is less stiff along the b direction than for the a and c directions. Effective mass calculations suggest that hole transport behavior is more anisotropic than electron transport, but the mass values allow for some charge mobility except along a direction perpendicular to the molecular layers of L-asparagine which form the crystal, so anhydrous monoclinic L-asparagine crystals could behave as wide gap semiconductors. Finally, the calculations point to a high degree of optical

  11. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  12. The Quantitative Measurements of Vascular Density and Flow Areas of Macula Using Optical Coherence Tomography Angiography in Normal Volunteers.

    Science.gov (United States)

    Ghassemi, Fariba; Fadakar, Kaveh; Bazvand, Fatemeh; Mirshahi, Reza; Mohebbi, Masoumeh; Sabour, Siamak

    2017-06-01

    The quantification of the density of macular vascular networks and blood flow areas in the foveal and parafoveal area in healthy subjects using optical coherence tomography angiography (OCTA). Cross-sectional, prospective study in an institutional setting at the Retina Services of Farabi Eye Hospital. One hundred twelve normal volunteers with no known ocular or systemic disease were included, including patient numbers (one or both eyes), selection procedures, inclusion/exclusion criteria, randomization procedure, and masking. En face angiogram OCTA was performed on a 3 mm × 3 mm region centered on the macula. Automated thresholding and measuring algorithm method for foveal and parafoveal blood flow and vascular density (VD) were used. The density of macular vascular networks and blood flow area in the foveal and parafoveal area were measured. A total of 224 healthy eyes from 112 subjects with a mean age of 36.4 years ± 11.3 years were included. In the foveal region, the VD of the superficial capillary network (sCN) was significantly higher than that of the deep capillary network (dCN) (31.1% ± 5.5% vs. 28.3% ± 7.2%; P < .001), whereas in the parafoveal area, VD was higher in the dCN (62.24% ± 2.8% vs. 56.5% ± 2.5%; P < .001). Flow area in the 1-mm radius circle in the sCN was less than in the dCN. Superficial foveal avascular zone (sFAZ) size was negatively correlated with the VD of the foveal sCN, but in the deep FAZ (dFAZ) was not correlated with VD or blood flow area of the fovea. There was no difference between measured VD and blood flow surface area in both eyes of the subjects. OCTA could be used as a noninvasive, repeatable, layer-free method in quantitative evaluation of VD and blood flow of macular area. The normal quantities of the vascular plexus density and flow will help in better understanding the pathophysiological basis of the vascular disease of retina. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:478-486.]. Copyright 2017, SLACK

  13. The association between breast tissue optical content and mammographic density in pre- and post-menopausal women.

    Directory of Open Access Journals (Sweden)

    Kristina M Blackmore

    Full Text Available Mammographic density (MD, associated with higher water and lower fat content in the breast, is strongly related to breast cancer risk. Optical attenuation spectroscopy (OS is a non-imaging method of evaluating breast tissue composition by red and near-infrared light transmitted through the breast that, unlike mammography, does not involve radiation. OS provides information on wavelength dependent light scattering of tissue and on absorption by water, lipid, oxy-, deoxy-hemoglobin. We propose that OS could be an alternative marker of breast cancer risk and that OS breast tissue measures will be associated with MD. In the present analysis, we developed an algorithm to estimate breast tissue composition and light scattering parameters using a spectrally constrained global fitting procedure employing a diffuse light transport model. OS measurements were obtained from 202 pre- and post-menopausal women with normal mammograms. Percent density (PD and dense area (DA were measured using Cumulus. The association between OS tissue composition and PD and DA was analyzed using linear regression adjusted for body mass index. Among pre-menopausal women, lipid content was significantly inversely associated with square root transformed PD (β = -0.05, p = 0.0002 and DA (β = -0.05, p = 0.019; water content was significantly positively associated with PD (β = 0.06, p = 0.008. Tissue oxygen saturation was marginally inversely associated with PD (β = -0.03, p = 0.057 but significantly inversely associated with DA (β = -0.10, p = 0.002. Among post-menopausal women lipid and water content were significantly associated (negatively and positively, respectively with PD (β lipid = -0.08, β water = 0.14, both p<0.0001 and DA (β lipid = -0.10, p<0.0001; β water = 0.11, p = 0.001. The association between OS breast content and PD and DA is consistent with more proliferation in dense tissue of younger women, greater lipid content in low density tissue and higher water

  14. Study on the interaction between tabersonine and human serum albumin by optical spectroscopy and molecular modeling methods

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Hua; Chen, Rongrong [Department of Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632 (China); Pu Hanlin, E-mail: tphl@jnu.edu.cn [Department of Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632 (China)

    2012-03-15

    The mechanism of interaction between tabersonine (TAB) and human serum albumin (HSA) was investigated by the methods of fluorescence spectroscopy, UV-vis absorption spectroscopy and molecular modeling under simulative physiological conditions. Results obtained from analysis of fluorescence spectrum and fluorescence intensity indicated that TAB has a strong ability to quench the intrinsic fluorescence of HSA through a static quenching procedure. The binding site number n and apparent binding constant K{sub a}, corresponding thermodynamic parameters {Delta}G, {Delta}H and {Delta}S at different temperatures were calculated. The distance r between donor (human serum albumin) and acceptor (tabersonine) was obtained according to the Foerster theory of non-radiation energy transfer. The effect of common ions on binding constant was also investigated. The synchronous fluorescence and three-dimensional fluorescence spectra were used to investigate the structural change of HSA molecules with addition of TAB. Furthermore, the study of molecular modeling indicated that TAB could bind to the site I of HSA and hydrophobic interaction was the major acting force, which was in agreement with the binding mode study. - Highlights: Black-Right-Pointing-Pointer Fluorescence study of the mechanism of interaction between tabersonine and HSA. Black-Right-Pointing-Pointer The binding parameters and thermodynamic parameters were calculated. Black-Right-Pointing-Pointer The distance r was obtained and common ions effects was investigated. Black-Right-Pointing-Pointer Conformation of HSA and its molecular modeling was analyzed.

  15. Concentrations of moxifloxacin in serum and pulmonary compartments following a single 400 mg oral dose in patients undergoing fibre-optic bronchoscopy.

    Science.gov (United States)

    Soman, A; Honeybourne, D; Andrews, J; Jevons, G; Wise, R

    1999-12-01

    The concentrations of moxifloxacin achieved after a single 400 mg dose were measured in serum, epithelial lining fluid (ELF), alveolar macrophages (AM) and bronchial mucosa (BM). Concentrations were determined using a microbiological assay. Nineteen patients undergoing fibre-optic bronchoscopy were studied. Mean serum, ELF, AM and BM concentrations at 2.2, 12 and 24 h were as follows: 2.2 h: 3.2 mg/L, 20.7 mg/L, 56.7 mg/L, 5.4 mg/kg; 12 h: 1.1 mg/L, 5.9 mg/L, 54.1 mg/L, 2.0 mg/kg; 24 h: 0.5 mg/L, 3.6 mg/L, 35.9 mg/L, 1.1 mg/kg, respectively. These concentrations exceed the MIC(90)s for common respiratory pathogens such as Streptococcus pneumoniae (0.25 mg/L), Haemophilus influenzae (0.03 mg/L), Moraxella catarrhalis (0.12 mg/L), Chlamydia pneumoniae (0.12 mg/L) and Mycoplasma pneumoniae (0. 12 mg/L) and indicate that moxifloxacin should be effective in the treatment of community-acquired, lower respiratory tract infections.

  16. Reducing classification error of grassland overgrowth by combing low-density lidar acquisitions and optical remote sensing data

    Science.gov (United States)

    Pitkänen, T. P.; Käyhkö, N.

    2017-08-01

    Mapping structural changes in vegetation dynamics has, for a long time, been carried out using satellite images, orthophotos and, more recently, airborne lidar acquisitions. Lidar has established its position as providing accurate material for structure-based analyses but its limited availability, relatively short history, and lack of spectral information, however, are generally impeding the use of lidar data for change detection purposes. A potential solution in respect of detecting both contemporary vegetation structures and their previous trajectories is to combine lidar acquisitions with optical remote sensing data, which can substantially extend the coverage, span and spectral range needed for vegetation mapping. In this study, we tested the simultaneous use of a single low-density lidar data set, a series of Landsat satellite frames and two high-resolution orthophotos to detect vegetation succession related to grassland overgrowth, i.e. encroachment of woody plants into semi-natural grasslands. We built several alternative Random Forest models with different sets of variables and tested the applicability of respective data sources for change detection purposes, aiming at distinguishing unchanged grassland and woodland areas from overgrown grasslands. Our results show that while lidar alone provides a solid basis for indicating structural differences between grassland and woodland vegetation, and orthophoto-generated variables alone are better in detecting successional changes, their combination works considerably better than its respective parts. More specifically, a model combining all the used data sets reduces the total error from 17.0% to 11.0% and omission error of detecting overgrown grasslands from 56.9% to 31.2%, when compared to model constructed solely based on lidar data. This pinpoints the efficiency of the approach where lidar-generated structural metrics are combined with optical and multitemporal observations, providing a workable framework to

  17. A Cross-Sectional Study Demonstrating Increased Serum Amyloid A Related Inflammation in High-Density Lipoproteins from Subjects with Type 1 Diabetes Mellitus and How This Association Was Augmented by Poor Glycaemic Control

    Directory of Open Access Journals (Sweden)

    Jane McEneny

    2015-01-01

    Full Text Available Inflammatory atherosclerosis is increased in subjects with type 1 diabetes mellitus (T1DM. Normally high-density lipoproteins (HDL protect against atherosclerosis; however, in the presence of serum amyloid-A- (SAA- related inflammation this property may be reduced. Fasting blood was obtained from fifty subjects with T1DM, together with fifty age, gender and BMI matched control subjects. HDL was subfractionated into HDL2 and HDL3 by rapid ultracentrifugation. Serum-hsCRP and serum-, HDL2-, and HDL3-SAA were measured by ELISAs. Compared to control subjects, SAA was increased in T1DM subjects, nonsignificantly in serum (P=0.088, and significantly in HDL2(P=0.003 and HDL3(P=0.005. When the T1DM group were separated according to mean HbA1c (8.34%, serum-SAA and HDL3-SAA levels were higher in the T1DM subjects with HbA1c ≥ 8.34%, compared to when HbA1c was 0.05. This cross-sectional study demonstrated increased SAA-related inflammation in subjects with T1DM that was augmented by poor glycaemic control. We suggest that SAA is a useful inflammatory biomarker in T1DM, which may contribute to their increased atherosclerosis risk.

  18. Cdx-2 polymorphism in Vitamin D Receptor gene was associated with serum 25-hydroxyvitamin D levels, bone mineral density and fracture in middle-aged and elderly Chinese women.

    Science.gov (United States)

    Ling, Yan; Lin, Huandong; Aleteng, Qiqige; Ma, Hui; Pan, Baishen; Gao, Jian; Gao, Xin

    2016-05-15

    The aim of the current study was to examine the relationship between Cdx-2 polymorphism in the promoter region of the VDR gene and serum 25-hydroxyvitamin D (25(OH)D) levels, bone mineral density (BMD) and fracture in Chinese population. This was a cross-sectional study, which included 738 individuals (428 women and 310 men) aged 45 years or older. In women, the association of Cdx-2 polymorphism with serum 25(OH)D levels was significant adjusting for age, BMI, estimated glomerular filtration rate, menopausal status and season of blood collection (P = 0.002). Cdx-2 polymorphism was associated with lumbar spine BMD adjusted for age, BMI, menopausal status and serum 25(OH)D in women (P = 0.005). But it was not associated with femoral neck BMD or total hip BMD in women. In women, Cdx-2 polymorphism was also associated with fracture adjusted for age, BMI, menopausal status, serum 25(OH)D and total hip BMD (P = 0.03). Carriers of AA and AG genotypes was associated with a higher odds of fracture compared with the carriers of GG genotype (OR = 2.14, 95% CI 1.04-4.42 and OR = 1.90, 95% CI 1.03-3.51). In men, Cdx-2 polymorphism was not associated with serum 25(OH)D levels, BMD or fracture. Our results indicate that the association of Cdx-2 polymorphism in the VDR gene with serum 25(OH)D levels, BMD and fracture may have sex differences. Cdx-2 polymorphism in the VDR gene may affect the serum 25(OH)D concentrations and the risk of osteoporosis and fracture in middle-aged and elderly Chinese women. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  20. Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma.

    Directory of Open Access Journals (Sweden)

    Masoud Aghsaei Fard

    Full Text Available Both non-arteritic anterior ischemic optic neuropathy (NAION and primary open-angle glaucoma (POAG damage retinal ganglion cell axons, which are perfused by the radial peripapillary capillaries. To evaluate the pattern of ischemia, we compared peripapillary capillary density (PCD in NAION eyes to POAG eyes matched for visual field mean deviation and retinal nerve fiber layer thickness.31 chronic NAION (>6 months after the acute event and unaffected fellow eyes (31 subjects, 42 moderate and severe POAG eyes (27 subjects, and 77 control eyes (46 healthy subjects were imaged with a commercial optical coherence tomography angiography system (AngioVue, Avanti RTVue-XR, Optovue, CA at two academic institutions. Two concentric circles of diameters 1.95mm (inner and 3.45mm (outer were manually placed on images centered on the optic nerve head, producing an annular region-of-interest. Image analysis with major vessel removal was performed using a custom program. Whole-image, whole-annulus, and sectoral PCDs were measured.Whole-image and whole-annulus PCDs in NAION and moderate and severe POAG eyes were significantly decreased compared to unaffected fellow eyes and control eyes (all P<0.001. Superior and temporal PCD values were affected more than other sectors in both NAION and POAG groups compared to control group. Whole-image and whole-annulus PCDs were not statistically different between NAION and POAG eyes (both P = 0.99. However, of all peripapillary sectors, the inferior sector PCD value was less affected in POAG eyes compared to NAION eyes (P = 0.001. Univariate analysis results also revealed a significant positive correlation between superior and inferior PCDs and corresponding RNFL thicknesses. The inferior sector correlation was greater in POAG than NAION eyes.While the whole PCD values were not different in chronic NAION and POAG, the greater correlation of inferior PCD with corresponding RNFL sectors in POAG compared to NAION suggests greater

  1. Optical to ultraviolet spectra of sandwiches of benzene and transition metal atoms: Time dependent density functional theory and many-body calculations

    DEFF Research Database (Denmark)

    Martinez, Jose Ignacio; García Lastra, Juan Maria; Lopez, M. J.

    2010-01-01

    The optical spectra of sandwich clusters formed by transition metal atoms (titanium, vanadium, and chromium) intercalated between parallel benzene molecules have been studied by time-dependent density functional theory (TDDFT) and many-body perturbation theory. Sandwiches with different number...

  2. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-07-01

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Reusable split-aptamer-based biosensor for rapid detection of cocaine in serum by using an all-fiber evanescent wave optical biosensing platform.

    Science.gov (United States)

    Tang, Yunfei; Long, Feng; Gu, Chunmei; Wang, Cheng; Han, Shitong; He, Miao

    2016-08-24

    A rapid, facile, and sensitive assay of cocaine in biological fluids is important to prevent illegal abuse of drugs. A two-step structure-switching aptasensor has been developed for cocaine detection based on evanescent wave optical biosensing platform. In the proposed biosensing platform, two tailored aptamer probes were used to construct the molecular structure switching. In the existence of cocaine, two fragments of cocaine aptamer formed a three-way junction quickly, and the fluorophore group of one fragment was effectively quenched by the quencher group of the other one. The tail of the three-way junction hybridized with the cDNA sequences immobilized on the optical fiber biosensor. Fluorescence was excited by evanescent wave, and the fluorescence signal was proportional to cocaine concentration. Cocaine was detected in 450 s (300 s for incubation and 150 s for detection and regeneration) with a limit of detection (LOD) of 165.2 nM. The proposed aptasensor was evaluated in human serum samples, and it exhibited good recovery, precision, and accuracy without complicated sample pretreatments. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Espectrofotometria de longo caminho óptico em espectrofotômetro de duplo-feixe convencional: uma alternativa simples para investigações de amostras com densidade óptica muito baixa Long optical path length spectrophotometry in conventional double-beam spectrophotometers: a simple alternative for investigating samples of very low optical density

    Directory of Open Access Journals (Sweden)

    André Luiz Galo

    2009-01-01

    Full Text Available We describe the design and tests of a set-up mounted in a conventional double beam spectrophotometer, which allows the determination of optical density of samples confined in a long liquid core waveguide (LCW capillary. Very long optical path length can be achieved with capillary cell, allowing measurements of samples with very low optical densities. The device uses a custom optical concentrator optically coupled to LCW (TEFLON® AF. Optical density measurements, carried out using a LCW of ~ 45 cm, were in accordance with the Beer-Lambert Law. Thus, it was possible to analyze quantitatively samples at concentrations 45 fold lower than that regularly used in spectrophotometric measurements.

  5. A Unique Report: Development of Super Anti-Human IgG Monoclone with Optical Density Over Than 3

    Directory of Open Access Journals (Sweden)

    Leili Aghebati Maleki

    2013-08-01

    Full Text Available Purpose: Monoclonal antibodies and related conjugates are key reagents used in biomedical researches as well as, in treatment, purification and diagnosis of infectious and non- infectious diseases. Methods: Balb/c mice were immunized with purified human IgG. Spleen cells of the most immune mouse were fused with SP2/0 in the presence of Poly Ethylene Glycol (PEG. Supernatant of hybridoma cells was screened for detection of antibody by ELISA. Then, the sample was assessed for cross-reactivity with IgM & IgA by ELISA and confirmed by immunoblotting. The subclasses of the selected mAbs were determined. The best clone was injected intraperitoneally to some pristane-injected mice. Anti-IgG mAb was purified from the animals' ascitic fluid by Ion exchange chromatography and then, mAb was conjugated with HRP. Results: In the present study, over than 50 clones were obtained that 1 clone had optical density over than 3. We named this clone as supermonoclone which was selected for limiting dilution. The result of the immunoblotting, showed sharp band in IgG position and did not show any band in IgM&IgA position. Conclusion: Based on the findings of this study, the conjugated monoclonal antibody could have application in diagnosis of infectious diseases like Toxoplasmosis, Rubella and IgG class of other infectious and non- infectious diseases.

  6. A Unique Report: Development of Super Anti-Human IgG Monoclone with Optical Density Over Than 3

    Science.gov (United States)

    Aghebati Maleki, Leili; Baradaran, Behzad; Abdolalizadeh, Jalal; Ezzatifar, Fatemeh; Majidi, Jafar

    2013-01-01

    Purpose: Monoclonal antibodies and related conjugates are key reagents used in biomedical researches as well as, in treatment, purification and diagnosis of infectious and non- infectious diseases. Methods: Balb/c mice were immunized with purified human IgG. Spleen cells of the most immune mouse were fused with SP2/0 in the presence of Poly Ethylene Glycol (PEG). Supernatant of hybridoma cells was screened for detection of antibody by ELISA. Then, the sample was assessed for cross-reactivity with IgM & IgA by ELISA and confirmed by immunoblotting. The subclasses of the selected mAbs were determined. The best clone was injected intraperitoneally to some pristane-injected mice. Anti-IgG mAb was purified from the animals' ascitic fluid by Ion exchange chromatography and then, mAb was conjugated with HRP. Results: In the present study, over than 50 clones were obtained that 1 clone had optical density over than 3. We named this clone as supermonoclone which was selected for limiting dilution. The result of the immunoblotting, showed sharp band in IgG position and did not show any band in IgM&IgA position. Conclusion: Based on the findings of this study, the conjugated monoclonal antibody could have application in diagnosis of infectious diseases like Toxoplasmosis, Rubella and IgG class of other infectious and non- infectious diseases. PMID:24312857

  7. First-principles X-ray absorption dose calculation for time-dependent mass and optical density.

    Science.gov (United States)

    Berejnov, Viatcheslav; Rubinstein, Boris; Melo, Lis G A; Hitchcock, Adam P

    2018-05-01

    A dose integral of time-dependent X-ray absorption under conditions of variable photon energy and changing sample mass is derived from first principles starting with the Beer-Lambert (BL) absorption model. For a given photon energy the BL dose integral D(e, t) reduces to the product of an effective time integral T(t) and a dose rate R(e). Two approximations of the time-dependent optical density, i.e. exponential A(t) = c + aexp(-bt) for first-order kinetics and hyperbolic A(t) = c + a/(b + t) for second-order kinetics, were considered for BL dose evaluation. For both models three methods of evaluating the effective time integral are considered: analytical integration, approximation by a function, and calculation of the asymptotic behaviour at large times. Data for poly(methyl methacrylate) and perfluorosulfonic acid polymers measured by scanning transmission soft X-ray microscopy were used to test the BL dose calculation. It was found that a previous method to calculate time-dependent dose underestimates the dose in mass loss situations, depending on the applied exposure time. All these methods here show that the BL dose is proportional to the exposure time D(e, t) ≃ K(e)t.

  8. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  9. Predictors of optical density of lutein and zeaxanthin in retinas of older women in the Carotenoids in Age-Related Eye Disease Study, an ancillary study of the Women's Health Initiative.

    Science.gov (United States)

    Mares, Julie A; LaRowe, Tara L; Snodderly, D Max; Moeller, Suzen M; Gruber, Michael J; Klein, Michael L; Wooten, Billy R; Johnson, Elizabeth J; Chappell, Richard J

    2006-11-01

    Lifestyle, diet, and physical and health predictors of xanthophyll carotenoids in the retina are poorly understood. We aimed to investigate the predictors of the density of lutein and zeaxanthin in the macula of the retina. Macular pigment optical density (MPOD) was measured by heterochromatic flicker photometry. Relations to dietary lutein and zeaxanthin and to other predictors were measured in 1698 women aged 53-86 y. The women were members of observational study cohorts of the Women's Health Initiative at Iowa City, IA, Madison, WI, or Portland, OR, and participated in the Carotenoids in Age-Related Eye Disease Study (2001-2004). MPOD at 0.5 degrees from the foveal center was 30% higher in women in the highest quintile for lutein and zeaxanthin intake [x (+/-SD): 0.40 +/- 0.21] than in women in the lowest quintile (0.31 +/- 0.21) and 20% higher after adjustment for other predictors. Dietary intake of lutein, zeaxanthin, fiber, and polyunsaturated fatty acids (% of energy) together explained 3% of the variability in MPOD. Higher waist circumference and diabetes, which are related to lower MPOD, together with study site explained an additional 5% of variation. The total explained variability increased to 12% when lutein and zexanthin concentrations obtained from the serum, which were collected 4-7 y earlier, were added to the model. MPOD is directly related to dietary intake of lutein and zeaxanthin but even more strongly to serum concentrations, which may reflect unmeasured physical and medical factors that influence the uptake, distribution, and utilization of lutein and zeaxanthin. Higher abdominal body fat and diabetes are related to lower MPOD. Unknown predictors of retinal carotenoids remain.

  10. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  11. An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

    International Nuclear Information System (INIS)

    Paniagua Gonzalez, Gema; Fernandez Hernando, Pilar; Durand Alegria, J. S.

    2009-01-01

    This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10 -3 mg L -1 . The detection limit was 3.17 x 10 -5 mg L -1 . Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10 -3 mg L -1 digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.

  12. An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane

    Energy Technology Data Exchange (ETDEWEB)

    Paniagua Gonzalez, Gema [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Fernandez Hernando, Pilar, E-mail: pfhernando@ccia.uned.es [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain); Durand Alegria, J. S. [Departamento de Ciencias Analiticas, Facultad de Ciencias, Universidad Nacional de Educacion a Distancia (UNED), 28040 Madrid (Spain)

    2009-04-13

    This paper reports the synthesis and testing of a molecularly imprinted polymer membrane for digoxin analysis. Digoxin-specific bulk polymer was obtained by the UV initiated co-polymerisation of methacrylic acid and ethylene glycol dimethacrylate in acetonitrile as porogen. After extracting the template analyte, the ground polymer particles were mixed with plasticizer polyvinyl chloride to form a MIP membrane. A reference polymer membrane was prepared from the same mixture of monomers but with no template. The resultant membrane morphologies were examined by scanning electron microscopy. The imprinted membrane was tested as the recognition element in a digoxin-sensitive fluorescence sensor; sensor response was measured using standard solutions of digoxin at concentrations of up to 4 x 10{sup -3} mg L{sup -1}. The detection limit was 3.17 x 10{sup -5} mg L{sup -1}. Within- and between-day relative standard deviations RSD (n = 5) were in the range 4.5-5.5% and 5.5-6.5% respectively for 0 and 1 x 10{sup -3} mg L{sup -1} digoxin concentrations. A selectivity study showed that compounds of similar structure to digoxin did not significantly interfere with detection for interferent concentrations at 10, 30 and 100 times higher than the digoxin concentration. This simply manufactured MIP membrane showed good recognition characteristics, a high affinity for digoxin, and provided satisfactory results in analyses of this analyte in human serum.

  13. High-density optical data storage based on grey level recording in photobleaching polymers using two-photon excitation under ultrashort pulse and continuous wave illumination

    International Nuclear Information System (INIS)

    Ganic, D.; Day, D.; Gu, M.

    1999-01-01

    Full text: Two-photon excitation has been employed in three-dimensional optical data storage by many researchers in an attempt to increase the storage density of a given material. The probability of two-photon excitation is proportional to the squared intensity of the incident light; this effect produces excitation only within a small region of the focus spot. Another advantage of two-photon excitation is the use of infrared illumination, which results in the reduction of scattering and enables the recording of layers at a deep depth in a thick material. The storage density thus obtained using multi-layered bit optical recording can be as high as Tbit/cm 3 . To increase this storage density even further, grey level recording can be employed. This method utilises variable exposure times of a laser beam focused into a photobleaching sample. As a result, the bleached area possesses a certain pixel value which depends upon the exposure time; this can increase the storage density many times depending upon the number of grey levels used. Our experiment shows that it is possible to attain grey level recording using both ultrashort pulsed and continuous-wave illumination. Although continuous wave illumination requires an average power of approximately 2 orders of magnitude higher than that for ultrashort pulsed illumination, it is a preferred method of recording due to its relatively low system cost and compactness. Copyright (1999) Australian Optical Society

  14. Electronic structure and optical properties of CdS{sub x}Se{sub 1−x} solid solution nanostructures from X-ray absorption near edge structure, X-ray excited optical luminescence, and density functional theory investigations

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, M. W. [DESY (Deutsches Elektronen-Synchrotron), FS-PEX, Notkestrasse 85, 22607 Hamburg (Germany); Yiu, Y. M., E-mail: yyiu@uwo.ca; Sham, T. K. [Department of Chemistry, University of Western Ontario, London, ON N6A5B7 (Canada); Ward, M. J. [Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, NY 14853 (United States); Liu, L. [Institute of Functional Nano and Soft Materials (FUNSOM) and Soochow University-Western University Center for Synchrotron Radiation Research, Soochow University, Suzhou, Jiangsu, 215123 (China); Hu, Y. [Canadian Light Source, University of Saskatchewan, Saskatoon, SK S7N2V3 (Canada); Zapien, J. A. [Center Of Super-Diamond and Advanced Films (COSDAF) and Department of Physics and Materials Science, City University of Hong Kong, Hong Kong SAR (China); Liu, Yingkai [Institute of Physics and Electronic Information, Yunnan Normal University, Kunming, Yunnan, 650500 (China)

    2014-11-21

    The electronic structure and optical properties of a series of iso-electronic and iso-structural CdS{sub x}Se{sub 1−x} solid solution nanostructures have been investigated using X-ray absorption near edge structure, extended X-ray absorption fine structure, and X-ray excited optical luminescence at various absorption edges of Cd, S, and Se. It is found that the system exhibits compositions, with variable local structure in-between that of CdS and CdSe accompanied by tunable optical band gap between that of CdS and CdSe. Theoretical calculation using density functional theory has been carried out to elucidate the observations. It is also found that luminescence induced by X-ray excitation shows new optical channels not observed previously with laser excitation. The implications of these observations are discussed.

  15. Relationship between optical coherence tomography sector peripapillary angioflow-density and Octopus visual field cluster mean defect values.

    Directory of Open Access Journals (Sweden)

    Gábor Holló

    Full Text Available To compare the relationship of Octopus perimeter cluster mean-defect (cluster MD values with the spatially corresponding optical coherence tomography (OCT sector peripapillary angioflow vessel-density (PAFD and sector retinal nerve fiber layer thickness (RNFLT values.High quality PAFD and RNFLT images acquired on the same day with the Angiovue/RTVue-XR Avanti OCT (Optovue Inc., Fremont, USA on 1 eye of 27 stable early-to-moderate glaucoma, 22 medically controlled ocular hypertensive and 13 healthy participants were analyzed. Octopus G2 normal visual field test was made within 3 months from the imaging.Total peripapillary PAFD and RNFLT showed similar strong positive correlation with global mean sensitivity (r-values: 0.6710 and 0.6088, P<0.0001, and similar (P = 0.9614 strong negative correlation (r-values: -0.4462 and -0.4412, P≤0.004 with global MD. Both inferotemporal and superotemporal sector PAFD were significantly (≤0.039 lower in glaucoma than in the other groups. No significant difference between the corresponding inferotemporal and superotemporal parameters was seen. The coefficient of determination (R2 calculated for the relationship between inferotemporal sector PAFD and superotemporal cluster MD (0.5141, P<0.0001 was significantly greater than that between inferotemporal sector RNFLT and superotemporal cluster MD (0.2546, P = 0.0001. The R2 values calculated for the relationships between superotemporal sector PAFD and RNFLT, and inferotemporal cluster MD were similar (0.3747 and 0.4037, respectively, P<0.0001.In the current population the relationship between inferotemporal sector PAFD and superotemporal cluster MD was strong. It was stronger than that between inferotemporal sector RNFLT and superotemporal cluster MD. Further investigations are necessary to clarify if our results are valid for other populations and can be usefully applied for glaucoma research.

  16. Retrieval of tropospheric NO2 vertical column densities and aerosol optical properties form MAXDOAS measurements in Yangtze River Delta, China

    Science.gov (United States)

    Hao, Nan; Van. Roozendael, Michel; Ding, Aijun; Zhou, Bin; Hendrick, François; Shen, Yicheng; Wang, Tin; Valks, Pieter

    2014-05-01

    Air pollution is one of the most important environmental problems in developing Asian countries like China. Due to huge consumption of fossil fuels and rapid increase of traffic emissions in the past decades, many regions in China have been experiencing heavy air pollution. The Yangtze River Delta (YRD) region includes the mega-city Shanghai and the well-industrialized and urbanized areas of Zhejiang Province and Jiangsu Province, with over ten large cities, such as Hangzhou, Suzhou and Nanjing. Covering only 2% land area, this region produces over 20% of China's Gross Domestic Product (GDP) which makes it the most densely populated region and one of the most polluted regions in China. For instance, there more than 60% of a year was haze days with poor visibility in Shanghai over the last few years. In the YRD region, knowledge gaps still exist in the understanding of the source and transport of air pollutants because only few measurement studies have been conducted. MAX-DOAS measurements were performed in Shanghai city center and Wujiang (border of Shanghai and Jiangsu Province) from 2010 to 2012 and in Nanjing (capital of Jiangsu Province) from April 2013. A retrieval algorithm, based on an on-line implementation of the radiative transfer code LIDORT and the optimal estimation technique, has been used to provide information on aerosol extinction vertical profiles. The total aerosol optical depths (AODs) calculated from the retrieved profiles were compared to MODIS, AERONET and local PM measurements. The aerosol information was input to LIDORT to calculate NO2 air mass factors. The retrieved tropospheric NO2 vertical column densities (VCDs) were compared to in-situ and satellite NO2 measurements.

  17. Significant Relationship Between Serum High-sensitivity C-Reactive Protein, High-density Lipoprotein Cholesterol Levels and Children With Kawasaki Disease and Coronary Artery Lesions

    Directory of Open Access Journals (Sweden)

    Chun-Yen Ou

    2009-09-01

    Conclusion: Our results support the possibility of ongoing low-grade inflammation late after the acute phase of KD in children with coronary aneurysms. Serum hs-CRP and HDL-C levels are associated with coronary artery lesions in children with KD.

  18. THE RELATIONSHIP BETWEEN FOVEAL AVASCULAR ZONE AREA, VESSEL DENSITY, AND CYSTOID CHANGES IN DIABETIC RETINOPATHY, AN OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY STUDY.

    Science.gov (United States)

    Tarassoly, Kia; Miraftabi, Arezoo; Soltan Sanjari, Mostafa; Parvaresh, Mohammad Mehdi

    2017-06-29

    To measure the foveal avascular zone (FAZ) areas and vessel densities of patients with diabetic retinopathy and to study their relationship with diabetic cystoid changes and retinal thickness. Prospective case series of 51 eyes of 31 patients with diabetic retinopathy. The eyes were grouped based on the presence or absence of cystoid edema and evaluated using optical coherence tomography angiography. The FAZ areas and vessel density were compared. The FAZ area at the superficial capillary plexus level was equal between the eyes with and without cystoid edema. Vessel density did not differ as well. There was no correlation with retinal thickness. In eyes with cystoid changes, FAZ area changes at the deep capillary plexus level were difficult to interpret. The FAZ area and vessel density at the superficial capillary plexus level are reproducible and independent of the presence of cystoid edema.

  19. Optical and magneto-optical characterization of TbFeCo and GdFeCo thin films for high-density recording

    International Nuclear Information System (INIS)

    Hendren, W R; Atkinson, R; Pollard, R J; Salter, I W; Wright, C D; Clegg, W W; Jenkins, D F L

    2003-01-01

    Thin, optically semi-infinite films of amorphous TbFeCo and GdFeCo, suitable for magneto-optical recording, have been deposited by DC magnetron sputtering onto glass. Ellipsometric techniques have been used to determine the complex refractive index and complex magneto-optical parameter of the films in the wavelength range 400-900 nm, thus characterizing the materials. A review of the literature is presented and shows that the results for the TbFeCo films compare favourably with published results obtained from measurements conducted in situ, with the films protected with ZnS barrier layers. It is found that GdFeCo and TbFeCo are optically very similar, but magneto-optically the materials are quite different

  20. Optical and magneto-optical characterization of TbFeCo and GdFeCo thin films for high-density recording

    Energy Technology Data Exchange (ETDEWEB)

    Hendren, W R [Department of Pure and Applied Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Atkinson, R [Department of Pure and Applied Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Pollard, R J [Department of Pure and Applied Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Salter, I W [Department of Pure and Applied Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Wright, C D [School of Engineering and Computer Science, University of Exeter, Exeter EX4 4QF (United Kingdom); Clegg, W W [CRIST, University of Plymouth, Plymouth PL4 8AA (United Kingdom); Jenkins, D F L [CRIST, University of Plymouth, Plymouth PL4 8AA (United Kingdom)

    2003-03-12

    Thin, optically semi-infinite films of amorphous TbFeCo and GdFeCo, suitable for magneto-optical recording, have been deposited by DC magnetron sputtering onto glass. Ellipsometric techniques have been used to determine the complex refractive index and complex magneto-optical parameter of the films in the wavelength range 400-900 nm, thus characterizing the materials. A review of the literature is presented and shows that the results for the TbFeCo films compare favourably with published results obtained from measurements conducted in situ, with the films protected with ZnS barrier layers. It is found that GdFeCo and TbFeCo are optically very similar, but magneto-optically the materials are quite different.

  1. Normal values of bone mineral density of the accessory carpus bone in Brasileiro de Hipismo (BH) horse breed using optical densitometry in radiographic image

    International Nuclear Information System (INIS)

    Godoy, C.L.B. de; Vulcano, L.C.; Santos, F.A.M.; Soares, J.C.M.

    2005-01-01

    Physiologic values of the bone mineral density (BMD) of the accessory carpal bone in Brasileiro de Hipismo (BH) horse breed were determined by radiographic optic densitometry (ROD), expressed in milimiters of alumminun (mmAl). Lateromedial radiographs of the carpus were taken from 12 intact males and 12 females, from 20 and up to 30 months of age. No significant difference was found in the average mineral bone density of the accessory carpal bone between males (4.7 ± 0.1mmAl) and females (4.,6 ± 0,1mmAl) from 20 to 30 months of age [pt

  2. MOVPE grown InGaAs quantum dots of high optical quality as seed layer for low-density InP quantum dots

    International Nuclear Information System (INIS)

    Richter, D; Hafenbrak, R; Joens, K D; Schulz, W-M; Eichfelder, M; Rossbach, R; Jetter, M; Michler, P

    2010-01-01

    To achieve a low density of optically active InP-quantum dots we used InGaAs islands embedded in GaAs as a seed layer. First, the structural InGaAs quantum dot properties and the influence of the annealing technique was investigated by atomic force microscope measurements. High-resolution micro-photoluminescence spectra reveal narrow photoluminescence lines, with linewidths down to 11 μeV and fine structure splittings of 25 μeV. Furthermore, using these InGaAs quantum dots as seed layer reduces the InP quantum dot density of optically active quantum dots drastically. InP quantum dot excitonic photoluminescence emission with a linewidth of 140 μeV has been observed.

  3. Quantification of Macular Vascular Density Using Optical Coherence Tomography Angiography and Its Relationship with Retinal Thickness in Myopic Eyes of Young Adults

    Directory of Open Access Journals (Sweden)

    Shiqi Yang

    2017-01-01

    Full Text Available Purpose. To quantify macular vascular density using optical coherence tomography angiography (OCTA and to investigate its relationship with retinal thickness in myopic eyes of young adults. Methods. In this cross-sectional study, 268 myopic eyes without pathological changes were recruited and divided into three groups: mild myopia (n=81, moderate myopia (n=117, and high myopia (n=70. Macular vascular density was quantified by OCTA and compared among three groups. Average retinal thickness, central subfield thickness, and macular ganglion cell complex (mGCC thickness were also evaluated and compared. Correlations among these variables were analyzed. Results. There was no statistical difference in superficial (62.3 ± 5.7% versus 62.7 ± 5.9% versus 63.8 ± 5.5% and deep macular vascular densities (58.3 ± 9.6% versus 59.2 ± 9.3% versus 60.9 ± 7.9% among mild-myopia, moderate-myopia, and high-myopia groups (both P>0.05. Superficial and deep macular vascular densities both had correlations with mean arterial pressure. Furthermore, superficial macular vascular density was significantly correlated with mGCC thickness. Conclusions. Varying degrees of myopia did not affect macular vascular density in young healthy adults. In addition, superficial macular vascular density, as an independent factor, was positively correlated with mGCC thickness.

  4. LAST II: Differential temporal responses of macular pigment optical density in patients with atrophic age-related macular degeneration to dietary supplementation with xanthophylls.

    Science.gov (United States)

    Richer, Stuart; Devenport, Jenny; Lang, John C

    2007-05-01

    Age-related macular degeneration (ARMD) is the leading cause of vision loss in aging Western societies. The objective of the Lutein Antioxidant Supplementation Trial (LAST) was to determine whether specific dietary interventions increased macular pigment optical density (MPOD) and visual function in patients with atrophic ARMD. The current objective of LAST II is to discern those specific characteristics that increase MPOD, i.e., that might differentiate a responder from a nonresponder. The LAST study was a prospective, 12-month, randomized, double-masked, placebo-controlled trial conducted at an urban midwestern Veterans Administation Hospital from August 1999 to May 2001. Ninety patients with atrophic ARMD entered the study and were assigned randomly to 1 of 3 groups. Patients in group 1 received 10 mg lutein; in group 2, 10 mg lutein in combination with vitamins, minerals, and antioxidants; and in group 3, maltodextrin placebo. Changes in macular MPOD over time were evaluated. Characteristics potentially influencing MPOD included age, weight (body mass index), initial baseline values of macular pigment, and combining xanthophylls with other nutrients. MPOD increased with supplementation and declined slightly without supplementation (regression slopes not equal to zero in supplemented groups, P < 0.02). The highest increases in MPOD over time occurred in patients with lower baseline values of MPOD. Statistically significant increases in MPOD density were observed in the lutein group for patients with baseline MPOD optical density units and up to 0.2 optical density units in the lutein plus antioxidant group. Further analysis found that none of the subjects' eyes in the lowest quartile of baseline MPOD were in the lowest quartile for change in MPOD. Noteworthy is the observation that those individuals with lowest MPOD, and in greatest need of supplementation, were also most likely to benefit from either the lutein or the lutein plus antioxidant

  5. Effect of insulin combined alendronate sodium on bone mineral density and levels of serum BAP, TRAP-5b and BGP in aged patients with type 2 diabetes mellitus with osteoporosis

    Directory of Open Access Journals (Sweden)

    Fang Wang

    2016-06-01

    Full Text Available Objective: To explore the effect of insulin combined alendronate sodium on bone mineral density and levels of serum BAP, TRAP-5b and BGP in aged patients with type 2 diabetes mellitus with osteoporosis. Methods: A total of 136 patients with type 2 diabetes mellitus with osteoporosis in January 2014 to January 2016 in our hospital for the treatment were selected, and randomly divided into 4 groups, each of 40 cases. Caltrate D was given as a basic treatment to all the patients, and the control group was given the treatment of insulin, and the metformin group was given the treatment of metformin, and the combination group was given the treatment of metformin combined alendronate, and the experiment group was given the treatment of insulin combined alendronate. BMD of the femoral neck and the serum levels of BAP, TRAP-5b and BGP were detected and recorded before the treatment and after one year’s treatment. Results: On index of bone mineral density, the control group and the metformin group showed no significant differences; the combination group was slightly improved, but showed no statistical significance; After the treatment, the bone mineral density of the experiment was significantly improved. On index of bone turnover, the levels of serum BAP and BGP all had been improved and the level of TRAP-5b all was reduced then before the treatment in the control group, the combination group and the experiment group, but only the experiment group showed significant differences; On index of bone turnover, the experiment group were better than other groups, the differences were statistical significant. Conclusions: It has greater clinical curative effect that insulin combined alendronate sodium in the treatment of aged patients with type 2 diabetes mellitus with osteoporosis, it can effectively balance the metabolism of bone, safe and reliable, and it is worthy of application.

  6. Optical properties of body-centered tetragonal C4: Insights from many-body perturbation and time-dependent density functional theories

    Science.gov (United States)

    Tarighi Ahmadpour, Mahdi; Rostamnejadi, Ali; Hashemifar, S. Javad

    2018-04-01

    We study the electronic structure and optical properties of a body-centered tetragonal phase of carbon (bct-C4) within the framework of time-dependent density functional theory and Bethe-Salpeter equation. The results indicate that the optical properties of bct-C4 are strongly affected by the electron-hole interaction. It is demonstrated that the long-range corrected exchange-correlation kernels could fairly reproduce the Bethe-Salpeter equation results. The effective carrier number reveals that at energies above 30 eV, the excitonic effects are not dominant any more and that the optical transitions originate mainly from electronic excitations. The emerged peaks in the calculated electron energy loss spectra are discussed in terms of plasmon excitations and interband transitions. The results of the research indicate that bct-C4 is an indirect wide-band-gap semiconductor, which is transparent in the visible region and opaque in the ultraviolet spectral range.

  7. AN EXPLANATION FOR THE DIFFERENT X-RAY TO OPTICAL COLUMN DENSITIES IN THE ENVIRONMENTS OF GAMMA RAY BURSTS: A PROGENITOR EMBEDDED IN A DENSE MEDIUM

    International Nuclear Information System (INIS)

    Krongold, Yair; Prochaska, J. Xavier

    2013-01-01

    We study the ∼> 10 ratios in the X-ray to optical column densities inferred from afterglow spectra of gamma ray bursts (GRBs) due to gas surrounding their progenitors. We present time-evolving photoionization calculations for these afterglows and explore different conditions of their environment. We find that homogenous models of the environment (constant density) predict X-ray columns similar to those found in the optical spectra, with the bulk of the opacity being produced by neutral material at large distances from the burst. This result is independent of gas density or metallicity. Only models assuming a progenitor immersed in a dense (∼10 2-4 cm –3 ) cloud of gas (with radius ∼10 pc), with a strong, declining gradient of density for the surrounding interstellar medium (ISM) are able to account for the large X-ray to optical column density ratios. However, to avoid an unphysical correlation between the size of this cloud and the size of the ionization front produced by the GRB, the models also require that the circumburst medium is already ionized prior to the burst. The inferred cloud masses are ∼ 6 M ☉ , even if low metallicities in the medium are assumed (Z ∼ 0.1 Z ☉ ). These cloud properties are consistent with those found in giant molecular clouds and our results support a scenario in which the progenitors reside within intense star formation regions of galaxies. Finally, we show that modeling over large samples of GRB afterglows may offer strong constraints on the range of properties in these clouds, and the host galaxy ISM

  8. Reproducibility of Macular Pigment Optical Density Measurement by Two-wave Length Auto-fluorescence in a Clinical Setting

    Science.gov (United States)

    You, Qi-Sheng; Bartsch, Dirk-Uwe G.; Espina, Mark; Alam, Mostafa; Camacho, Natalia; Mendoza, Nadia; Freeman, William

    2015-01-01

    Purpose Macular pigment, composed of lutein, zeaxanthin, and meso-zeaxanthin, is postulated to protect against age-related macular degeneration (AMD), likely due to filtering blue light and its antioxidant properties. Macular pigment optical density (MPOD) is reported to be associated with macular function evaluated by visual acuity and multifocal electroretinogram. Given the importance of macular pigment, reliable and accurate measurement methods are important. The main purpose of current study is to determine the reproducibility of MPOD measurement by two-wave length auto-fluorescence method using scanning laser ophthalmoscopy. Methods Sixty eight eyes of 39 persons were enrolled in the study, including 11 normal eyes, 16 eyes with wet AMD, 16 eyes with dry AMD, 11 eyes with macular edema due to diabetic mellitus, branch retinal vein occlusion or macular telangiectasia and 14 eyes with tractional maculopathy including vitreomacular traction, epiretinal membrane or macular hole. MPOD was measured with a two-wavelength (488 and 514 nm) auto-fluorescence method with the Spectralis HRA+OCT after pupil dilation. The measurement was repeated for each eye 10 minutes later. The Analysis of variance (ANOVA) and Bland-Altman plot were used to assess the reproducibility between the two measurements. Results The mean MPOD at eccentricities of 1° and 2° was 0.36±0.17 (range: 0.04–0.69) and 0.15±0.08(range: −0.03, 0.35) for the first measurement and 0.35±0.17 (range: 0.02, 0.68) and 0.15±0.08 (range: −0.01, 0.33) for the second measurement respectively. The difference between the two measurements was not statistically significant, and the Bland-Altman plot showed 7.4% and 5.9% points outside the 95% limits of agreement, indicating an overall excellent reproducibility. Similarly, there is no significant difference between the first and second measurements of MPOD volume within eccentricities of 1°, 2° and 6° radius, and the Bland-Altman plot showed 8.8%, 2.9% and

  9. Reliability of a two-wavelength autofluorescence technique by Heidelberg Spectralis to measure macular pigment optical density in Asian subjects.

    Science.gov (United States)

    Obana, Akira; Gellermann, Werner; Gohto, Yuko; Seto, Takahiko; Sasano, Hiroyuki; Tanito, Masaki; Okazaki, Shigetoshi

    2018-03-01

    This study evaluates the accuracy of an objective two-wavelength fundus autofluorescence technique for the purpose of measuring the macular pigment optical density (MPOD) in Asian pigmented eyes. Potential differences between MPOD values obtained via autofluorescence technique and subjective heterochromatic photometry (HFP) were examined. Inter-examiner reproducibility between three examiners and test-retest reliability over five time points were also explored. Subjects were 27 healthy Japanese volunteers aged 24 to 58 (mean ± standard deviation, 40.2 ± 9.0) years. An MPOD module of the Spectralis MultiColor instrument configuration (Spectralis-MP) was used for the autofluorescence technique, and a Macular Metrics Densitometer (MM) was used for HFP. The mean MPOD values at 0.25° and 0.5° eccentricities using the Spectralis-MP were 0.51 ± 0.12 and 0.48 ± 0.13, respectively. In comparison, the MM based values were 0.72 ± 0.23 and 0.61 ± 0.25, respectively. High correlations between the Spectralis-MP and MM instrument were found (Pearson's correlation coefficients of 0.73 and 0.87 at 0.25° and 0.5° eccentricities, respectively), but there was a systematic bias: the MPOD values by MM method were significantly higher than those by Spectralis-MP at 0.25° eccentricity. High inter-examiner reproducibility and test-retest reliability were found for MM measurements at 0.5° eccentricity, but not at 0.25°. The Spectralis-MP showed less inter-examiner and test-retest variability than the MM instrument at 0.25° and 0.5° eccentricities. We conclude that the Spectralis-MP, given its high agreement with the HFP method and due to its higher reproducibility and reliability, is well suited for clinical measurements of MPOD levels in Asian pigmented eyes. Copyright © 2018. Published by Elsevier Ltd.

  10. Long-term culture of rat hippocampal neurons at low density in serum-free medium: combination of the sandwich culture technique with the three-dimensional nanofibrous hydrogel PuraMatrix.

    Science.gov (United States)

    Kaneko, Ai; Sankai, Yoshiyuki

    2014-01-01

    The primary culture of neuronal cells plays an important role in neuroscience. There has long been a need for methods enabling the long-term culture of primary neurons at low density, in defined serum-free medium. However, the lower the cell density, the more difficult it is to maintain the cells in culture. Therefore, we aimed to develop a method for long-term culture of neurons at low density, in serum-free medium, without the need for a glial feeder layer. Here, we describe the work leading to our determination of a protocol for long-term (>2 months) primary culture of rat hippocampal neurons in serum-free medium at the low density of 3×10(4) cells/mL (8.9×10(3) cells/cm2) without a glial feeder layer. Neurons were cultured on a three-dimensional nanofibrous hydrogel, PuraMatrix, and sandwiched under a coverslip to reproduce the in vivo environment, including the three-dimensional extracellular matrix, low-oxygen conditions, and exposure to concentrated paracrine factors. We examined the effects of varying PuraMatrix concentrations, the timing and presence or absence of a coverslip, the timing of neuronal isolation from embryos, cell density at plating, medium components, and changing the medium or not on parameters such as developmental pattern, cell viability, neuronal ratio, and neurite length. Using our method of combining the sandwich culture technique with PuraMatrix in Neurobasal medium/B27/L-glutamine for primary neuron culture, we achieved longer neurites (≥3,000 µm), greater cell viability (≥30%) for 2 months, and uniform culture across the wells. We also achieved an average neuronal ratio of 97%, showing a nearly pure culture of neurons without astrocytes. Our method is considerably better than techniques for the primary culture of neurons, and eliminates the need for a glial feeder layer. It also exhibits continued support for axonal elongation and synaptic activity for long periods (>6 weeks).

  11. Long-term culture of rat hippocampal neurons at low density in serum-free medium: combination of the sandwich culture technique with the three-dimensional nanofibrous hydrogel PuraMatrix.

    Directory of Open Access Journals (Sweden)

    Ai Kaneko

    Full Text Available The primary culture of neuronal cells plays an important role in neuroscience. There has long been a need for methods enabling the long-term culture of primary neurons at low density, in defined serum-free medium. However, the lower the cell density, the more difficult it is to maintain the cells in culture. Therefore, we aimed to develop a method for long-term culture of neurons at low density, in serum-free medium, without the need for a glial feeder layer. Here, we describe the work leading to our determination of a protocol for long-term (>2 months primary culture of rat hippocampal neurons in serum-free medium at the low density of 3×10(4 cells/mL (8.9×10(3 cells/cm2 without a glial feeder layer. Neurons were cultured on a three-dimensional nanofibrous hydrogel, PuraMatrix, and sandwiched under a coverslip to reproduce the in vivo environment, including the three-dimensional extracellular matrix, low-oxygen conditions, and exposure to concentrated paracrine factors. We examined the effects of varying PuraMatrix concentrations, the timing and presence or absence of a coverslip, the timing of neuronal isolation from embryos, cell density at plating, medium components, and changing the medium or not on parameters such as developmental pattern, cell viability, neuronal ratio, and neurite length. Using our method of combining the sandwich culture technique with PuraMatrix in Neurobasal medium/B27/L-glutamine for primary neuron culture, we achieved longer neurites (≥3,000 µm, greater cell viability (≥30% for 2 months, and uniform culture across the wells. We also achieved an average neuronal ratio of 97%, showing a nearly pure culture of neurons without astrocytes. Our method is considerably better than techniques for the primary culture of neurons, and eliminates the need for a glial feeder layer. It also exhibits continued support for axonal elongation and synaptic activity for long periods (>6 weeks.

  12. Structural, electronic, and optical properties of GaInO{sub 3}: A hybrid density functional study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, V., E-mail: wangvei@icloud.com; Ma, D.-M.; Liu, R.-J.; Yang, C.-M. [Department of Applied Physics, Xi' an University of Technology, Xi' an 710054 (China); Xiao, W. [State Key Lab of Nonferrous Metals and Processes, General Research Institute for Nonferrous Metals, Beijing 100088 (China)

    2014-01-28

    The structural, electronic, and optical properties of GaInO{sub 3} have been studied by first-principles calculations based on Heyd-Scuseria-Ernzerhof hybrid functional theory. The optical properties, including the optical reflectivity, refractive index, extinction coefficient, absorption coefficient, and electron energy loss are discussed for radiation up to 60 eV together with the calculated electronic structure. Our results predicted that GaInO{sub 3} displays good transparency over the whole vision region, which is in good agreement with the experimental data available in the literature.

  13. Correlations Between Macular, Skin, and Serum Carotenoids

    Science.gov (United States)

    Conrady, Christopher D.; Bell, James P.; Besch, Brian M.; Gorusupudi, Aruna; Farnsworth, Kelliann; Ermakov, Igor; Sharifzadeh, Mohsen; Ermakova, Maia; Gellermann, Werner; Bernstein, Paul S.

    2017-01-01

    Purpose Ocular and systemic measurement and imaging of the macular carotenoids lutein and zeaxanthin have been employed extensively as potential biomarkers of AMD risk. In this study, we systematically compare dual wavelength retinal autofluorescence imaging (AFI) of macular pigment with skin resonance Raman spectroscopy (RRS) and serum carotenoid levels in a clinic-based population. Methods Eighty-eight patients were recruited from retina and general ophthalmology practices from a tertiary referral center and excluded only if they did not have all three modalities tested, had a diagnosis of macular telangiectasia (MacTel) or Stargardt disease, or had poor AFI image quality. Skin, macular, and serum carotenoid levels were measured by RRS, AFI, and HPLC, respectively. Results Skin RRS measurements and serum zeaxanthin concentrations correlated most strongly with AFI macular pigment volume under the curve (MPVUC) measurements up to 9° eccentricity relative to MPVUC or rotationally averaged macular pigment optical density (MPOD) measurements at smaller eccentricities. These measurements were reproducible and not significantly affected by cataracts. We also found that these techniques could readily identify subjects taking oral carotenoid-containing supplements. Conclusions Larger macular pigment volume AFI and skin RRS measurements are noninvasive, objective, and reliable methods to assess ocular and systemic carotenoid levels. They are an attractive alternative to psychophysical and optical methods that measure MPOD at a limited number of eccentricities. Consequently, skin RRS and MPVUC at 9° are both reasonable biomarkers of macular carotenoid status that could be readily adapted to research and clinical settings. PMID:28728169

  14. Prediction of the filter no-reflow phenomenon in patients with angina pectoris by using multimodality: Magnetic resonance imaging, optical coherence tomography, and serum biomarkers.

    Science.gov (United States)

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Otsuka, Kenichiro; Yoshikawa, Junichi; Shimada, Kenei

    2016-05-01

    Although the occurrence of no-reflow during percutaneous coronary intervention (PCI) has been shown to be associated with worse short- and long-term clinical outcomes, the clinical relevance of preventing flow deterioration by using the filter-based distal protection devices (DPDs) is controversial. We investigated predictors of the filter no-reflow (FNR) phenomenon during PCI by using multimodality, such as hyperintense plaques (HIPs) in the coronary artery on T1-weighted imaging (T1WI) non-contrast magnetic resonance, plaque composition by using optical coherence tomography (OCT), and serum biomarkers, in patients with angina pectoris. Fifty lesions from 50 patients with angina were examined. All patients underwent T1WI within 24 h before invasive coronary angiography was performed, and preinterventional OCT was performed on a native atherosclerotic culprit lesion. The signal intensity of coronary plaque to cardiac muscle ratio (PMR) was calculated on a standard console of the magnetic resonance system. Of the 50 lesions, 20 lesions showed FNR during PCI, while non-FNR was observed in 30 lesions. A cut-off value >1.85 of PMR had a sensitivity of 65%, a specificity of 93%, a positive predictive value of 87%, and a negative predictive value of 80% for identifying lesions with FNR. Multivariate analysis revealed that the presence of HIPs with PMR >1.85 (p=0.008) was the only independent predictor of the FNR phenomenon during PCI. This study shows that the presence of HIPs with PMR >1.85 on T1WI was a novel independent predictor of the FNR phenomenon during PCI in angina patients. This result may help in identifying high-risk lesions for no-reflow to deploy filter-based DPDs. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  15. Structural, magnetic, electronic and optical properties of PuC and PuC{sub 0.75}: A hybrid density functional study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rong [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610065 (China); College of Materials Science and Engineering, Chongqing Jiaotong University, Chongqing 400074 (China); Tang, Bin [School of Business Administration, Chongqing City Management College, Chongqing 401331 (China); Gao, Tao, E-mail: gaotao@scu.edu.cn [Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610065 (China); Ao, BingYun, E-mail: aobingyun@caep.cn [Science and Technology on Surface Physics and Chemistry Laboratory, P.O. Box 718-35, Mianyang 621907 (China)

    2016-05-15

    We perform first principles calculations to investigate the structural, magnetic, electronic and optical properties of PuC and PuC{sub 0.75}. Furthermore, we examine the influence of carbon non-stoichiometry on plutonium monocarbide. For the treatment of strongly correlated electrons, the hybrid density functionals like PBE0, Fock-0.25 are used and we compare the results with the generalized gradient approximation (GGA), local density approximation (LDA), LDA + U and experimental ones. The optimized lattice constant a{sub 0} = 4.961 Å for PuC in the Fock-0.25 scheme is the most close to the experimental data. The ground states of PuC and PuC{sub 0.75} are found to be anti-ferromagnetic. Our results indicate that additional removal of a C atom make lattice contract and new DOS peak appear in the near-Fermi region. We also compute and compare the optical properties of PuC and PuC{sub 0.75}. The difference in optical properties between PuC and PuC{sub 0.75} should also be the influence of carbon vacancies.

  16. Precise measurements of spatial density distributions of damages introduced into GaP by MeV-electron beam irradiations based on its optical properties

    International Nuclear Information System (INIS)

    Endo, T.; Hashimoto, Y.; Nakanishi, Y.; Wada, T.

    1985-01-01

    GaP crystals were irradiated uniformly on their flat surfaces by 10 MeV-electrons. The 'below-gap' absorption coefficient Δαsub(b)(hν) and the normalized white-light optical density D/d in these samples increased linearly with a dose phi as Δαsub(b)(2.0) = 3.3 x 10 -16 phi and D/d = 1.42 x 10 -16 phi. The free electron density n in the conduction band estimated from the X 1 -> X 3 absorption band decreased with phi, and as the decrease in the free electron density Δn is equivalent to the density of introduced defects N, it could be expressed that N = Δn = Rsub(c)phi where the value of the carrier removal rate Rsub(c) was 5.8 cm -1 for the S-doped sample. These expressions lead to the basic relation that N is proportional to D/d as expressed in N = 4.1 x 10 16 D/d. Two-dimensional distributions of D/d were measured in the samples irradiated by collimated electron beams at 10 and 16 MeV by using a microdensitometer, and they were converted into the two-dimensional distributions of damage density according to the linear relation of N-D/d. Damages gradually spread laterally with increasing depth at first and then shrink. (author)

  17. density functional theory approach

    Indian Academy of Sciences (India)

    YOGESH ERANDE

    2017-07-27

    Jul 27, 2017 ... a key role in all optical switching devices, since their optical properties can be .... optimized in the gas phase using Density Functional Theory. (DFT).39 The ...... The Mediation of Electrostatic Effects by Sol- vents J. Am. Chem.

  18. Estimation of optical rotation of γ-alkylidenebutenolide, cyclopropylamine, cyclopropyl-methanol and cyclopropenone based compounds by a Density Functional Theory (DFT) approach.

    Science.gov (United States)

    Shahzadi, Iram; Shaukat, Aqsa; Zara, Zeenat; Irfan, Muhammad; Eliasson, Bertil; Ayub, Khurshid; Iqbal, Javed

    2017-10-01

    Computing the optical rotation of organic molecules can be a real challenge, and various theoretical approaches have been developed in this regard. A benchmark study of optical rotation of various classes of compounds was carried out by Density Functional Theory (DFT) methods. The aim of the present research study was to find out the best-suited functional and basis set to estimate the optical rotations of selected compounds with respect to experimental literature values. Six DFT functional LSDA, BVP86, CAM-B3LYP, B3PW91, and PBE were applied on 22 different compounds. Furthermore, six different basis sets, i.e., 3-21G, 6-31G, aug-cc-pVDZ, aug-cc-pVTZ, DGDZVP, and DGDZVP2 were also applied with the best-suited functional B3LYP. After rigorous effort, it can be safely said that the best combination of functional and basis set is B3LYP/aug-cc-pVTZ for the estimation of optical rotation for selected compounds. © 2017 Wiley Periodicals, Inc.

  19. Effects of disorder on atomic density waves and spin-singlet dimers in one-dimensional optical lattices

    International Nuclear Information System (INIS)

    Gao Xianlong

    2008-01-01

    Using the Bethe-ansatz density-functional theory, we study a one-dimensional Hubbard model of confined attractively interacting fermions in the presence of a uniformly distributed disorder. The strongly correlated Luther-Emery nature of the attractive one-dimensional Hubbard model is fully taken into account as the reference system in the density-functional theory. The effects of the disorder are investigated on the atomic density waves in the weak-to-intermediate attractive interaction and on the spin-singlet dimers of doubly occupied sites in the strongly attractive regime. It is found that atomic density waves are sensitive to the disorder and the spin-singlet dimers of doubly occupied sites are quite unstable against the disorder. We also show that a very weak disorder could smear the singularities in the stiffness, thus, suppresses the spin-singlet pairs

  20. Structural, electronic, optical and thermoelectric investigations of antiperovskites A3SnO (A = Ca, Sr, Ba) using density functional theory

    Science.gov (United States)

    Hassan, M.; Shahid, A.; Mahmood, Q.

    2018-02-01

    Density functional theory study of the structural, electrical, optical and thermoelectric behaviors of very less investigated anti-perovskites A3SnO (A = Ca, Sr, Ba) is performed with FP-LAPW technique. The A3SnO exhibit narrow direct band gap, in contrast to the wide indirect band gap of the respective perovskites. Hence, indirect to direct band gap transformation can be realized by the structural transition from perovskite to anti-perovskite. The p-p hybridization between A and O states result in the covalent bonding. The transparency and maximum reflectivity to the certain energies, and the verification of the Penn's model indicate potential optical device applications. Thermoelectric behaviors computed within 200-800 K depict that Ca3SnO exhibits good thermoelectric performance than Ba3SnO and Sr3SnO, and all three operate at their best at 800 K suggesting high temperature thermoelectric device applications.

  1. Raman spectroscopic measurements of CO2 density: Experimental calibration with high-pressure optical cell (HPOC) and fused silica capillary capsule (FSCC) with application to fluid inclusion observations

    Science.gov (United States)

    Wang, X.; Chou, I-Ming; Hu, W.; Burruss, Robert; Sun, Q.; Song, Y.

    2011-01-01

    Raman spectroscopy is a powerful method for the determination of CO2 densities in fluid inclusions, especially for those with small size and/or low fluid density. The relationship between CO2 Fermi diad split (Δ, cm−1) and CO2 density (ρ, g/cm3) has been documented by several previous studies. However, significant discrepancies exist among these studies mainly because of inconsistent calibration procedures and lack of measurements for CO2fluids having densities between 0.21 and 0.75 g/cm3, where liquid and vapor phases coexist near room temperature.In this study, a high-pressure optical cell and fused silica capillary capsules were used to prepare pure CO2 samples with densities between 0.0472 and 1.0060 g/cm3. The measured CO2 Fermi diad splits were calibrated with two well established Raman bands of benzonitrile at 1192.6 and 1598.9 cm−1. The relationship between the CO2 Fermi diad split and density can be represented by: ρ = 47513.64243 − 1374.824414 × Δ + 13.25586152 × Δ2 − 0.04258891551 × Δ3(r2 = 0.99835, σ = 0.0253 g/cm3), and this relationship was tested by synthetic fluid inclusions and natural CO2-rich fluid inclusions. The effects of temperature and the presence of H2O and CH4 on this relationship were also examined.

  2. Exploiting the Error-Correcting Capabilities of Low Density Parity Check Codes in Distributed Video Coding using Optical Flow

    DEFF Research Database (Denmark)

    Rakêt, Lars Lau; Søgaard, Jacob; Salmistraro, Matteo

    2012-01-01

    We consider Distributed Video Coding (DVC) in presence of communication errors. First, we present DVC side information generation based on a new method of optical flow driven frame interpolation, where a highly optimized TV-L1 algorithm is used for the flow calculations and combine three flows....... Thereafter methods for exploiting the error-correcting capabilities of the LDPCA code in DVC are investigated. The proposed frame interpolation includes a symmetric flow constraint to the standard forward-backward frame interpolation scheme, which improves quality and handling of large motion. The three...... flows are combined in one solution. The proposed frame interpolation method consistently outperforms an overlapped block motion compensation scheme and a previous TV-L1 optical flow frame interpolation method with an average PSNR improvement of 1.3 dB and 2.3 dB respectively. For a GOP size of 2...

  3. Differential impact of serum glucose, triglycerides, and high-density lipoprotein cholesterol on cardiovascular risk factor burden in nondiabetic, obese African American women: implications for the prevalence of metabolic syndrome.

    Science.gov (United States)

    Gaillard, Trudy; Schuster, Dara; Osei, Kwame

    2010-08-01

    Metabolic syndrome (MetS) as defined by the Adult Treatment Panel (ATP) III criteria includes 3 metabolic parameters: serum glucose, triglycerides, and high-density lipoprotein cholesterol (HDL-C) measurements. However, the impact of each of the 3 metabolic parameters on cardiovascular disease (CVD) risk in African American women (AAW) is unknown. Therefore, we investigated CVD risk clusters associated with each of the 3 metabolic components of MetS in adult nondiabetic, overweight/obese AAW. We studied the clinical and metabolic CVD risk factors of 258 AAW (mean age, 42.4 +/- 8.4 years; mean body mass index, 33.4 +/- 8.0 (kg/m(2)). Fasting serum insulin, glucose, and C-peptide levels were obtained in each subject. Waist circumference and systolic and diastolic blood pressure were measured. Insulin sensitivity (Bergman minimal model method) and insulin resistance (homeostasis model assessment) were calculated. We examined the prevalence of MetS and its components associated with each of the 3 metabolic components (ie, serum glucose, HDL-C, and triglycerides) of the MetS as defined by ATP III. Worsening of any of the 3 metabolic parameters was associated with increasing waist circumference but not with age and body mass index nor with insulin, C-peptide, homeostasis model assessment of insulin resistance, and insulin sensitivity. As a group, the prevalence of MetS was 35.5% in our AAW. The prevalence of MetS increased 3-fold from first to third tertiles of serum glucose (14.1% and 42.3%, respectively). Worsening of serum HDL-C from tertiles 3 to 1 was associated with significant increases in the prevalence of MetS (1.2% vs 42.3%, respectively). Comparing first with third tertile of triglycerides, there was no significant increase in MetS in our AAW (7% vs 17%). Contrasting the 3 metabolic components, the prevalence of MetS was higher in the third tertile of glucose (43.2%) and first tertile of HDL-C (42.3%) and least with the third tertile of triglycerides (17%). In

  4. Local density of optical states in the band gap of a finite one-dimensional photonic crystal

    NARCIS (Netherlands)

    Yeganegi Dastgerdi, Elahe; Lagendijk, Aart; Mosk, Allard; Vos, Willem L.

    2014-01-01

    We study the local density of states (LDOS) in a finite photonic crystal, in particular in the frequency range of the band gap. We propose an original point of view on the band gap, which we consider to be the result of vacuum fluctuations in free space that tunnel in the forbidden range in the

  5. Novel aluminum near field transducer and highly integrated micro-nano-optics design for heat-assisted ultra-high-density magnetic recording

    International Nuclear Information System (INIS)

    Miao, Lingyun; Hsiang, Thomas Y; Stoddart, Paul R

    2014-01-01

    Heat-assisted magnetic recording (HAMR) has attracted increasing attention as one of the most promising future techniques for ultra-high-density magnetic recording beyond the current limit of 1 Tb in −2 . Localized surface plasmon resonance plays an important role in HAMR by providing a highly focused optical spot for heating the recording medium within a small volume. In this work, we report an aluminum near-field transducer (NFT) based on a novel bow-tie design. At an operating wavelength of 450 nm, the proposed transducer can generate a 35 nm spot size inside the magnetic recording medium, corresponding to a recording density of up to 2 Tb in −2 . A highly integrated micro-nano-optics design is also proposed to ensure process compatibility and corrosion-resistance of the aluminum NFT. Our work has demonstrated the feasibility of using aluminum as a plasmonic material for HAMR, with advantages of reduced cost and improved efficiency compared to traditional noble metals. (paper)

  6. Determination of auto-antibodies to native and oxidized low-density lipoproteins (LDL) in serum of patients underwent coronariography in the Medical-Surgical Research Center (MSRC)

    International Nuclear Information System (INIS)

    Conde CerdeiraI, Hector; Soto Lopez, Yosdel; Aroche Aportela, Ronald

    2010-01-01

    Low-density lipoprotein (LDL) oxidation is an important event in atherosclerosis development. The relationship between oxidized LDL (oxLDL) autoantibodies and coronary artery disease (CAD) remains controversial. IgM and IgG autoantibodies to oxLDL were measured in twenty patients undergoing clinically indicated coronary angiography, and in ten young healthy volunteers from the Center of Molecular Immunology. The levels of IgM autoantibodies to oxLDL did not differ between no CAD patients and healthy subjects, but the levels of IgM autoantibodies to oxLDL of these two groups were higher compared with the one of CAD patient group. Our results, although preliminary, supports the hypothesis that this kind of Abs might be inversely associated with the presence of atherosclerosis

  7. Effects of shape and dopant on structural, optical absorption, Raman, and vibrational properties of silver and copper quantum clusters: A density functional theory study

    International Nuclear Information System (INIS)

    Li Wei-Yin; Chen Fu-Yi

    2014-01-01

    We investigate the effects of shape and single-atom doping on the structural, optical absorption, Raman, and vibrational properties of Ag 13 , Ag 12 Cu 1 , Cu 13 , and Cu 12 Ag 1 clusters by using the (time-dependent) density functional theory. The results show that the most stable structures are cuboctahedron (COh) for Ag 13 and icosahedron (Ih) for Cu 13 , Ag 12 Cu 1core , and Cu 12 Ag 1sur . In the visible—near infrared optical absorption, the transitions consist of the interband and the intraband transitions. Moreover, red shifts are observed as follows: 1) clusters change from Ag 12 Cu 1core to Ag 13 to Ag 12 Cu 1sur with the same motifs, 2) the shapes of pure Ag 13 and Ag 12 Cu 1core clusters change from COh to Ih to decahedron (Dh), 3) the shape of Ag 12 Cu 1sur clusters changes from Ih to COh to Dh, and 4) the shapes of pure Cu 13 and Cu 12 Ag 1 clusters change from Ih to Dh to COh. All of the Raman and vibrational spectra exhibit many significant vibrational modes related to the shapes and the compositions of the clusters. The ranges of vibrational spectra of Ag 13 , Ag 12 Cu 1 or Cu 13 , and Cu 12 Ag 1 clusters become narrower and the vibrational intensities increase as the shape of the clusters changes from Ih to Dh to COh. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  8. Electronic structure and optical properties of Sr{sub 2}SnO{sub 4} studied with FP-LAPW method in density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Prijamboedi, B., E-mail: boedi@chem.itb.ac.id; Umar, S.; Failamani, F. [Inorganic and Physical Chemistry Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia)

    2015-04-16

    Oxide material of Sr{sub 2}SnO{sub 4}, when it is doped with Ti becomes a phosphor material that can emit intense blue light at room temperature. It is important to study the electronic structure of this material in order to determine the optical processes that occur in Ti-doped Sr{sub 2}SnO{sub 4}. Electronic structure and optical properties of Sr{sub 2}SnO{sub 4} is studied using density functional theory framework with full potential linearized augmented plane waves plus local orbitals (FP-LAPW+lo) method. We use modified Becke-Johnson (mBJ) exchange-correlation potential to calculate the energy gap. Our calculation showed that Sr{sub 2}SnO{sub 4} has indirect band gap with band gap energy of around 4.2 eV. The experimental absorption spectra of Sr{sub 2}SnO{sub 4} indicated that this oxide has band gap of around 4.6 eV and it is closer to the results given by mBJ exchange-correlation potential. We also studied other optical properties of Sr{sub 2}SnO{sub 4} and it is found in agreement with the experimental results.

  9. Electron dynamics and optical properties modulation of monolayer MoS{sub 2} by femtosecond laser pulse: a simulation using time-dependent density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Su, Xiaoxing; Jiang, Lan [Beijing Institute of Technology, Laser Micro/Nano Fabrication Laboratory, School of Mechanical Engineering, Beijing (China); Wang, Feng [Beijing Institute of Technology, School of Physics, Beijing (China); Su, Gaoshi [Beijing Institute of Technology, School of Mechatronical Engineering, Beijing (China); Qu, Liangti [Beijing Institute of Technology, Key Laboratory of Cluster Science, Ministry of Education, School of Chemistry, Beijing (China); Lu, Yongfeng [University of Nebraska-Lincoln, Department of Electrical Engineering, Lincoln, NE (United States)

    2017-07-15

    In this study, we adopted time-dependent density functional theory to investigate the optical properties of monolayer MoS{sub 2} and the effect of intense few-cycle femtosecond laser pulses on these properties. The electron dynamics of monolayer MoS{sub 2} under few-cycle and multi-cycle laser irradiation were described. The polarization direction of the laser had a marked effect on the energy absorption and electronic excitation of monolayer MoS{sub 2} because of anisotropy. Change in the polarization direction of few-cycle pulse changed the absorbed energy by a factor over 4000. Few-cycle pulse showed a higher sensitivity to the electronic property of material than multi-cycle pulse. The modulation of the dielectric properties of the material was observed on the femtosecond time scale. The negative divergence appeared in the real part of the function at low frequencies and photoinduced blue shift occurred due to Burstein-Moss effect. The irradiation of femtosecond laser caused the dielectric response within the infrared region and introduced anisotropy to the in-plane optical properties. Laser-based engineering of optical properties through controlling transient electron dynamics expands the functionality of MoS{sub 2} and has potential applications in direction-dependent optoelectronic devices. (orig.)

  10. Ultra-precision fabrication of high density micro-optical backbone interconnections for data center and mobile application

    Science.gov (United States)

    Lohmann, U.; Jahns, J.; Wagner, T.; Werner, C.

    2012-10-01

    A microoptical 3D interconnection scheme and fabricated samples of this fiberoptical multi-channel interconnec- tion with an actual capacity of 144 channels were shown. Additionally the aspects of micrometer-fabrication of such microoptical interconnection modules in the view of alignment-tolerances were considered. For the realiza- tion of the interconnection schemes, the approach of planar-integrated free space optics (PIFSO) is used with its well known advantages. This approach offers the potential for complex interconnectivity, and yet compact size.

  11. Multicanonical evaluation of the tails of the probability density function of semiconductor optical amplifier output power fluctuations

    DEFF Research Database (Denmark)

    Tromborg, Bjarne; Reimer, Michael; Yevick, David

    2010-01-01

    This paper presents a multicanonical Monte Carlo method for simulating the tails of a pdf distribution of the filtered output power from a semiconductor optical amplifier down to values of the order of 10−40. The influence of memory effects on the pdf is examined in order to demonstrate the manner...... in which the calculated pdf approaches the true pdf with increasing integration time. The simulated pdf is shown to be in good agreement with a second order analytic expression for the pdf....

  12. Medical diagnosis system and method with multispectral imaging. [depth of burns and optical density of the skin

    Science.gov (United States)

    Anselmo, V. J.; Reilly, T. H. (Inventor)

    1979-01-01

    A skin diagnosis system includes a scanning and optical arrangement whereby light reflected from each incremental area (pixel) of the skin is directed simultaneously to three separate light filters, e.g., IR, red, and green. As a result, the three devices simultaneously produce three signals which are directly related to the reflectance of light of different wavelengths from the corresponding pixel. These three signals for each pixel after processing are used as inputs to one or more output devices to produce a visual color display and/or a hard copy color print, for one usable as a diagnostic aid by a physician.

  13. Association between serum triglyceride to high-density lipoprotein cholesterol ratio and sarcopenia in elderly Korean males: The Korean National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Chung, Tae-Ha; Kwon, Yu-Jin; Shim, Jae-Yong; Lee, Yong-Jae

    2016-12-01

    We investigated the association between the triglycerides to high-density lipoprotein cholesterol (TG/HDL) ratio and sarcopenia in elderly Korean males. We examined the relationship between the TG/HDL ratio and sarcopenia in 879 elderly males ≥60years who participated in the 2010-2011 KNHANES. Sarcopenia was defined as an appendicular skeletal muscle mass (ASM) divided by the weight (%), which is >1 SD below the mean for young adults. The odds ratios (ORs) for sarcopenia were calculated using multiple logistic regression across the TG/HDL ratio quartiles (Q1: ≤1.4, Q2: 1.5-2.4, Q3: 2.5-3.8 and Q4: ≥3.9) after adjusting for confounding variables. The prevalence of sarcopenia significantly increased in accordance with TG/HDL ratio quartiles. Compared with the lowest quartile of the TG/HDL ratio, the corresponding OR (95% CI) of the highest quartile of the TG/HDL ratio for sarcopenia was 2.10 (1.12-3.91) after adjusting for age, body mass index (BMI), cigarette smoking, alcohol intake and physical activity. TG/HDL ratio was positively related with a higher risk of sarcopenia in elderly Korean males. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. In vivo polarization-sensitive optical coherence tomography of human burn scars: birefringence quantification and correspondence with histologically determined collagen density

    Science.gov (United States)

    Jaspers, Mariëlle E. H.; Feroldi, Fabio; Vlig, Marcel; de Boer, Johannes F.; van Zuijlen, Paul P. M.

    2017-12-01

    Obtaining adequate information on scar characteristics is important for monitoring their evolution and the effectiveness of clinical treatment. The aberrant type of collagen in scars may give rise to specific birefringent properties, which can be determined using polarization-sensitive optical coherence tomography (PS-OCT). The aim of this pilot study was to evaluate a method to quantify the birefringence of the scanned volume and correlate it with the collagen density as measured from histological slides. Five human burn scars were measured in vivo using a handheld probe and custom-made PS-OCT system. The local retardation caused by the tissue birefringence was extracted using the Jones formalism. To compare the samples, histograms of birefringence values of each volume were produced. After imaging, punch biopsies were harvested from the scar area of interest and sent in for histological evaluation using Herovici polychrome staining. Two-dimensional en face maps showed higher birefringence in scars compared to healthy skin. The Pearson's correlation coefficient for the collagen density as measured by histology versus the measured birefringence was calculated at r=0.80 (p=0.105). In conclusion, the custom-made PS-OCT system was capable of in vivo imaging and quantifying the birefringence of human burn scars, and a nonsignificant correlation between PS-OCT birefringence and histological collagen density was found.

  15. Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach

    Science.gov (United States)

    Yong, WANG; Cong, LI; Jielin, SHI; Xingwei, WU; Hongbin, DING

    2017-11-01

    As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering (LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5 × 1019 m-3 to 7.1 × 1020 m-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison, an optical emission spectroscopy (OES) system was established as well. The results showed that the electron excitation temperature (configuration temperature) measured by OES is significantly higher than the electron temperature (kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium (LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.

  16. Density-optimized efficiency for magneto-optical production of a stable molecular Bose-Einstein condensate

    Energy Technology Data Exchange (ETDEWEB)

    Mackie, Matt [Helsinki Institute of Physics, PL 64, FIN-00014 Helsingin yliopisto (Finland); Collin, Anssi [Helsinki Institute of Physics, PL 64, FIN-00014 Helsingin yliopisto (Finland); Suominen, Kalle-Antti [Helsinki Institute of Physics, PL 64, FIN-00014 Helsingin yliopisto (Finland); Javanainen, Juha [Department of Physics, University of Connecticut, Storrs, CT 06269-3046 (United States)

    2003-08-01

    Although photoassociation and the Feshbach resonance are feasible means in principle for creating a molecular Bose-Einstein condensate (MBEC) from an already quantum-degenerate gas of atoms, collision-induced mean-field shifts and irreversible decay place practical constraints on the efficient Raman delivery of stable molecules. Focusing on stimulated Raman adiabatic passage, we propose that the efficiency of both mechanisms for producing a stable MBEC can be improved by treating the density of the initial atom condensate as an optimization parameter.

  17. Serum sickness

    Science.gov (United States)

    ... the problem should be stopped. Avoid using that medicine or antiserum in the future. ... Call your provider if you received medicine or antiserum in the last 4 weeks and have symptoms of serum sickness.

  18. The effect of industrial processing of salmon oil on its ability to reduce serum concentrations of oxidized low-density lipoprotein- β2-glycoprotein-I complex in a mouse model

    Directory of Open Access Journals (Sweden)

    Bomi Framroze

    2014-10-01

    Full Text Available Background: Circulating serum levels of oxidized low-density lipoprotein, β2-glycoprotein I complex (oxLDL-GP, have been previously correlated with adverse cardiovascular events and have been shown to be reduced by consumption of enzymatically liberated extra virgin salmon oil (EVSO. This mouse study measured the changes in the oxLDL-GP lowering effect when consuming EVSO with varying levels of EPA+DHA (eicosapentenoic acid and docosahexenoic acid as well as when consuming EVSO that was subjected to various processing treatments commonly carried out during fish oil production. Methods: Sprague Dawley mice were fed a diet containing eight different EVSO’s incorporated into a normal diet at the Human Equivalent Dose (HED of 1000 mg for 8 weeks. Serum was collected at the start and at the end of the trial and the oxLDL-GP concentrations were measured using an ELISA assay. Statistical analysis of the results was carried out using a 1-tail, paired Student t-Test. Results: In order to lower circulatory oxLDL-GP levels, the mice had to consume a minimum of 80 mg per day HED of EPA+DHA. Heat treatment of the EVSO did not affect this bioactivity but hydrolysis with acid or base and re-esterification to the triglyceride form or significant oxidation (rancidity rendered the oil inactive on this important cardio-vascular disease (CVD biomarker. Conclusions: This result shows that harsh processing conditions on fish oils can lead to the destruction of biological efficacy in spite of increasing the concentration of typical fish oil bioactive constituents such as EPA+DHA. It also lends support to the developing nutrition theory that eating highly-refined, processed or concentrated-ingredient supplements derived from functional foods may not be able to reproduce their full nutritive and health-benefiting effects

  19. Gene-gene combination effect and interactions among ABCA1, APOA1, SR-B1, and CETP polymorphisms for serum high-density lipoprotein-cholesterol in the Japanese population.

    Directory of Open Access Journals (Sweden)

    Akihiko Nakamura

    Full Text Available BACKGROUND/OBJECTIVE: Gene-gene interactions in the reverse cholesterol transport system for high-density lipoprotein-cholesterol (HDL-C are poorly understood. The present study observed gene-gene combination effect and interactions between single nucleotide polymorphisms (SNPs in ABCA1, APOA1, SR-B1, and CETP in serum HDL-C from a cross-sectional study in the Japanese population. METHODS: The study population comprised 1,535 men and 1,515 women aged 35-69 years who were enrolled in the Japan Multi-Institutional Collaborative Cohort (J-MICC Study. We selected 13 SNPs in the ABCA1, APOA1, CETP, and SR-B1 genes in the reverse cholesterol transport system. The effects of genetic and environmental factors were assessed using general linear and logistic regression models after adjusting for age, sex, and region. PRINCIPAL FINDINGS: Alcohol consumption and daily activity were positively associated with HDL-C levels, whereas smoking had a negative relationship. The T allele of CETP, rs3764261, was correlated with higher HDL-C levels and had the highest coefficient (2.93 mg/dL/allele among the 13 SNPs, which was statistically significant after applying the Bonferroni correction (p<0.001. Gene-gene combination analysis revealed that CETP rs3764261 was associated with high HDL-C levels with any combination of SNPs from ABCA1, APOA1, and SR-B1, although no gene-gene interaction was apparent. An increasing trend for serum HDL-C was also observed with an increasing number of alleles (p<0.001. CONCLUSIONS: The present study identified a multiplier effect from a polymorphism in CETP with ABCA1, APOA1, and SR-B1, as well as a dose-dependence according to the number of alleles present.

  20. Effects of inter-tube coupling on the electro-optical properties of silicon carbide nanotube bundles studied by density functional theory

    Science.gov (United States)

    Behzad, Somayeh

    2015-09-01

    The electronic and optical properties of bundled armchair and zigzag silicon carbide nanotubes (SiCNTs) are investigated by using density functional theory. The effects of inter-tube coupling on the electronic dispersions of SiCNT bundles are demonstrated. It was found that the band structure of (6, 0) SiCNT bundle shows metallic feature. The calculated dielectric functions of the armchair and zigzag bundles are similar to that of the isolated tubes, except for the appearance of broadened peaks, small shifts of peak positions about 0.1 eV and increasing of peak intensities. For (6, 0) SiCNT with smaller radius, by considering interband and interaband transitions, the band structure coupling causes an extra peak at low energies.

  1. Structural, optical, mechanical and density functional theory studies of 1H-pyrazol-2-ium hydrogen oxalate crystal

    Energy Technology Data Exchange (ETDEWEB)

    Devi, P. Karthiga, E-mail: karthvi19@gmail.com; Venkatachalam, K.

    2016-11-01

    In the present work, we have grown 1H- pyrazol-2-ium hydrogen oxalate single crystal by slow evaporation solution growth technique. The lattice parameters are determined from single crystal X ray diffraction studies. The functional groups present in the compound are confirmed by Fourier transform infrared spectroscopy. UV-Vis analysis shows that the crystal has a wide transparency window. Vicker's hardness test has been carried out to estimate the stiffness constant, fracture toughness, brittleness index and yield strength of the crystal. Density functional study B3LYP method at 6-31 G (d, p) has been performed to study the optimized structure, HOMO-LUMO energy gap, hyperpolarizability and thermodynamic properties. - Highlights: • The title compound was analyzed using FTIR and UV–Vis spectroscopy. • Mechanical study was carried out using Vicker's hardness test. • Optimized molecular geometry was determined using DFT method. • Hydrogen bonding interaction was studied through NBO analysis.

  2. Dissolved oxygen concentration profiles in the hyporheic zone through the use of a high density fiber optic measurement network

    Science.gov (United States)

    Reeder, W. J.; Quick, A. M.; Farrell, T. B.; Benner, S. G.; Feris, K. P.; Tonina, D.

    2013-12-01

    The hyporheic zone (HZ) is a potentially important source of the potent greenhouse gas, nitrous oxide (N2O); stream processes may account for up to 10% of global anthropogenic N2O emissions. However, mechanistic understanding and predictive quantification of this gas flux is hampered by complex temporally and spatially variable interactions between flow dynamics and biogeochemical processes. Reactive inorganic nitrogen (Nr) is typically present at low concentrations in natural stream waters, but many rural and urban streams suffer from an excess of Nr, typically in the form of ammonium (NH4+) and nitrate (NO3-). These reactive species are either assimilated by living biomass or transformed by microbial processes. The two primary microbial transformations of Nr are nitrification (NH4+ to NO3-) and denitrification (NO3- to N2). Denitrification, which occurs almost exclusively in the anoxic zone of the HZ, permanently removes between 30-70% of all Nr entering streams, other mechanisms may retain nitrogen. The mass transport of reactive species (i.e. O2, NO3- and N2O) by hyporheic flow strongly influences reaction rates, residence times, and subsequent N2O flux. By extension, stream flow and channel morphology presumably control, and may be effective predictors of, N2O generation rates. By recreating the stream processes in the University of Idaho flume, we are able to control the bed morphology, fluxes and residence times through the HZ and concentrations of Nr from exogenous (stream water) and endogenous (organic material in the streambed) sources. For the present experiment, the flume was divided into three streams, each with different morphologies (3, 6 and 9cm dunes) and all using the same source water. Stream water for this first experimental phase had no significant loading of Nr. As such, all reaction products were the result of endogenous sources of Nr. To measure dissolved oxygen (DO) concentrations we deployed 120 channels of a novel, fiber-optic optode

  3. Optical Quantification of Cellular Mass, Volume, and Density of Circulating Tumor Cells Identified in an Ovarian Cancer Patient

    International Nuclear Information System (INIS)

    Phillips, Kevin G.; Velasco, Carmen Ruiz; Li, Julia; Kolatkar, Anand; Luttgen, Madelyn; Bethel, Kelly; Duggan, Bridgette; Kuhn, Peter; McCarty, Owen J. T.

    2012-01-01

    Clinical studies have demonstrated that circulating tumor cells (CTCs) are present in the blood of cancer patients with known metastatic disease across the major types of epithelial malignancies. Recent studies have shown that the concentration of CTCs in the blood is prognostic of overall survival in breast, prostate, colorectal, and non-small cell lung cancer. This study characterizes CTCs identified using the high-definition (HD)-CTC assay in an ovarian cancer patient with stage IIIC disease. We characterized the physical properties of 31 HD-CTCs and 50 normal leukocytes from a single blood draw taken just prior to the initial debulking surgery. We utilized a non-interferometric quantitative phase microscopy technique using brightfield imagery to measure cellular dry mass. Next we used a quantitative differential interference contrast microscopy technique to measure cellular volume. These techniques were combined to determine cellular dry mass density. We found that HD-CTCs were more massive than leukocytes: 33.6 ± 3.2 pg (HD-CTC) compared to 18.7 ± 0.6 pg (leukocytes), p < 0.001; had greater volumes: 518.3 ± 24.5 fL (HD-CTC) compared to 230.9 ± 78.5 fL (leukocyte), p < 0.001; and possessed a decreased dry mass density with respect to leukocytes: 0.065 ± 0.006 pg/fL (HD-CTC) compared to 0.085 ± 0.004 pg/fL (leukocyte), p < 0.006. Quantification of HD-CTC dry mass content and volume provide key insights into the fluid dynamics of cancer, and may provide the rationale for strategies to isolate, monitor or target CTCs based on their physical properties. The parameters reported here can also be incorporated into blood cell flow models to better understand metastasis.

  4. Absorbed dose in AgBr in direct film for photon energies (<150 keV): relation to optical density. Theoretical calculation and experimental evaluation

    International Nuclear Information System (INIS)

    Helmrot, E.; Alm Carlsson, G.

    1996-01-01

    Calculations of absorbed dose in the silver bromide were compared with measurements of optical densities in Ultra-speed and Ektaspeed films for a broad range (25-145 kV) of X-ray energy. The calculated absorbed dose values were appropriately averaged over the complete photon energy spectrum, which was determined experimentally using a Compton spectrometer. For the whole range of tube potentials used, the measured optical densities of the films were found to be proportional to the mean absorbed dose in the AgBr grains calculated according to GREENING's theory. They were also found to be proportional to the collision kerma in silver bromide (K c,AgBr ) indicating proportionality between K c,AgBr and the mean absorbed dose in silver bromide. While GREENING's theory shows that the quotient of the mean absorbed dose in silver bromide and K c,AgBr varies with photon energy, this is not apparent when averaged over the broad (diagnostic) X-ray energy spectra used here. Alternatively, proportionality between K c,AgBr and the mean absorbed dose in silver bromide can be interpreted as resulting from a combination of the SPIERS-CHARLTON theory, valid at low photon energies ( c,AgBr (at the position of the film) independent of photon energy. The importance of taking the complete X-ray energy spectrum into full account in deriving K c,AgBr is clearly demonstrated, showing that the concept of effective energy must be used with care. (orig./HP)

  5. Experimental and density functional theory (DFT): A dual approach to probe the key properties of creatininium L-tartrate monohydrate single crystal for nonlinear optical applications

    Science.gov (United States)

    Thirumurugan, R.; Babu, B.; Anitha, K.; Chandrasekaran, J.

    2017-12-01

    A novel organic nonlinear optical (NLO) material, creatininium L-tartrate monohydrate (CTM) was synthesized and it was grown as single crystals with optical quality. 1H and 13C NMR spectral studies were performed and molecular structure of synthesized CTM compound was confirmed. Single crystal X-ray diffraction (SXRD) analysis confirmed that CTM was crystallized in orthorhombic system with non-centrosymmetric (NCS), P212121, space group. The grown crystal exhibited admirable properties such as second harmonic generation efficiency (SHG) (1.9 times KDP), and high laser damage threshold (LDT) value of 3.7 GW cm-2. CTM crystal displayed high transparency (∼60%) in the visible and near-IR region with low cut-off wavelength at 249 nm. Photoluminescence study confirmed blue wavelength emission (∼463 nm) of grown crystal. Thermal and mechanical behaviours have been successfully analysed for grown crystals. The dielectric studies were carried out for grown crystal as a function of frequencies at different temperatures. Hirshfeld surface and fingerprint plots provided the percentage of individual interactions contributed by each atom. Moreover, density functional theory (DFT) calculations have been employed to probe the frontier molecular orbitals (FMOs) and first hyperpolarizability (β) analysis of the optimized CTM structure. These results validated CTM as a suitable NLO candidate and were discussed in this work.

  6. Structural, optical and vibrational properties of Cr2O3 with ferromagnetic and antiferromagnetic order: A combined experimental and density functional theory study

    Science.gov (United States)

    Larbi, T.; Ouni, B.; Gantassi, A.; Doll, K.; Amlouk, M.; Manoubi, T.

    2017-12-01

    Chromium oxide (Cr2O3) thin films have been synthesized on glass substrates by the spray pyrolysis technique. The structural, morphological and optical properties of the sample have been studied by X-ray diffraction (XRD), Raman spectroscopy, FTIR spectroscopy, scanning probe microscopy and UV-vis spectroscopy respectively. X-ray diffraction results reveal that as deposited film is polycrystalline with a rhombohedral corundum structure and a preferential orientation of the crystallites along the (1 0 4) direction. IR and Raman spectra were recorded in the 100-900 cm-1 range and the observed modes were analysed and assigned to different normal modes of vibration. The direct optical band gap energy value calculated from the transmittance spectra of as-deposited thin film is about 3.38 eV. We employ first principles calculations based on density functional theory (DFT) with the B3LYP hybrid functional and a coupled perturbed Hartree-Fock/Kohn-Sham approach (CPHF/KS). We study the electronic structure, optimum geometry, and IR and Raman spectra of ferromagnetically and antiferromagnetically ordered Cr2O3. The computed results are consistent with the experimental measurements, and provide complete vibrational assignment, for the characterization of Cr2O3 thin film materials which can be used in photocatalysis and gas sensors.

  7. Stochastic singular optics (Conference paper)

    CSIR Research Space (South Africa)

    Roux, FS

    2014-09-01

    Full Text Available The study of optical vortices in stochastic optical fields involves various quantities, including the vortex density and topological charge density, that are defined in terms of local expectation values of distributions of optical vortices...

  8. Micro- and nano-scale optical devices for high density photonic integrated circuits at near-infrared wavelengths

    Science.gov (United States)

    Chatterjee, Rohit

    In this research work, we explore fundamental silicon-based active and passive photonic devices that can be integrated together to form functional photonic integrated circuits. The devices which include power splitters, switches and lenses are studied starting from their physics, their design and fabrication techniques and finally from an experimental standpoint. The experimental results reveal high performance devices that are compatible with standard CMOS fabrication processes and can be easily integrated with other devices for near infrared telecom applications. In Chapter 2, a novel method for optical switching using nanomechanical proximity perturbation technique is described and demonstrated. The method which is experimentally demonstrated employs relatively low powers, small chip footprint and is compatible with standard CMOS fabrication processes. Further, in Chapter 3, this method is applied to develop a hitless bypass switch aimed at solving an important issue in current wavelength division multiplexing systems namely hitless switching of reconfigurable optical add drop multiplexers. Experimental results are presented to demonstrate the application of the nanomechanical proximity perturbation technique to practical situations. In Chapter 4, a fundamental photonic component namely the power splitter is described. Power splitters are important components for any photonic integrated circuits because they help split the power from a single light source to multiple devices on the same chip so that different operations can be performed simultaneously. The power splitters demonstrated in this chapter are based on multimode interference principles resulting in highly compact low loss and highly uniform power splitting to split the power of the light from a single channel to two and four channels. These devices can further be scaled to achieve higher order splitting such as 1x16 and 1x32 power splits. Finally in Chapter 5 we overcome challenges in device

  9. Impact of hydrogen dilution on optical properties of intrinsic hydrogenated amorphous silicon films prepared by high density plasma chemical vapor deposition for solar cell applications

    Science.gov (United States)

    Chen, Huai-Yi; Lee, Yao-Jen; Chang, Chien-Pin; Koo, Horng-Show; Lai, Chiung-Hui

    2013-01-01

    P-i-n single-junction hydrogenated amorphous silicon (a-Si:H) thin film solar cells were successfully fabricated in this study on a glass substrate by high density plasma chemical vapor deposition (HDP-CVD) at low power of 50 W, low temperature of 200°C and various hydrogen dilution ratios (R). The open circuit voltage (Voc ), short circuit current density (Jsc ), fill factor (FF) and conversion efficiency (η) of the solar cell as well as the refractive index (n) and absorption coefficient (α) of the i-layer at 600 nm wavelength rise with increasing R until an abrupt drop at high hydrogen dilution, i.e. R > 0.95. However, the optical energy bandgap (Eg ) of the i-layer decreases with the R increase. Voc and α are inversely correlated with Eg . The hydrogen content affects the i-layer and p/i interface quality of the a-Si:H thin film solar cell with an optimal value of R = 0.95, which corresponds to solar cell conversion efficiency of 3.85%. The proposed a-Si:H thin film solar cell is expected to be improved in performance.

  10. Electronic and Optical Properties of Small Hydrogenated Silicon Quantum Dots Using Time-Dependent Density Functional Theory

    Directory of Open Access Journals (Sweden)

    Muhammad Mus-’ab Anas

    2015-01-01

    Full Text Available This paper presents a systematic study of the absorption spectrum of various sizes of small hydrogenated silicon quantum dots of quasi-spherical symmetry using the time-dependent density functional theory (TDDFT. In this study, real-time and real-space implementation of TDDFT involving full propagation of the time-dependent Kohn-Sham equations were used. The experimental results for SiH4 and Si5H12 showed good agreement with other earlier calculations and experimental data. Then these calculations were extended to study larger hydrogenated silicon quantum dots with diameter up to 1.6 nm. It was found that, for small quantum dots, the absorption spectrum is atomic-like while, for relatively larger (1.6 nm structure, it shows bulk-like behavior with continuous plateau with noticeable peak. This paper also studied the absorption coefficient of silicon quantum dots as a function of their size. Precisely, the dependence of dot size on the absorption threshold is elucidated. It was found that the silicon quantum dots exhibit direct transition of electron from HOMO to LUMO states; hence this theoretical contribution can be very valuable in discerning the microscopic processes for the future realization of optoelectronic devices.

  11. Structural, electronic and optical properties of monoclinic Na{sub 2}Ti{sub 3}O{sub 7} from density functional theory calculations: A comparison with XRD and optical absorption measurements

    Energy Technology Data Exchange (ETDEWEB)

    Araújo-Filho, Adailton A. [Departamento de Física, Universidade Federal do Ceará, Caixa Postal 6030, 60455-760 Fortaleza, CE (Brazil); Silva, Fábio L.R.; Righi, Ariete [Departamento de Física, Universidade Federal de Minas Gerais, Belo Horizonte, MG 31270-901 (Brazil); Silva, Mauricélio B. da; Silva, Bruno P. [Departamento de Física, Universidade Federal do Ceará, Caixa Postal 6030, 60455-760 Fortaleza, CE (Brazil); Caetano, Ewerton W.S., E-mail: ewcaetano@gmail.com [Instituto Federal de Educação, Ciência e Tecnologia do Ceará, 60040-531 Fortaleza, CE (Brazil); Freire, Valder N. [Departamento de Física, Universidade Federal do Ceará, Caixa Postal 6030, 60455-760 Fortaleza, CE (Brazil)

    2017-06-15

    Powder samples of bulk monoclinic sodium trititanate Na{sub 2}Ti{sub 3}O{sub 7} were prepared carefully by solid state reaction, and its monoclinic P2{sub 1}/m crystal structure and morphology were characterized by X-ray powder diffraction (XRD) and scanning electron microscopy (SEM), respectively. Moreover, the sodium trititanate main energy band gap was estimated as E{sub g}=3.51±0.01 eV employing UV–Vis spectroscopy, which is smaller than the measured 3.70 eV energy gap published previously by other authors. Aiming to achieve a better understanding of the experimental data, density functional theory (DFT) computations were performed within the local density and generalized gradient approximations (LDA and GGA, respectively) taking into account dispersion effects through the scheme of Tkatchenko and Scheffler (GGA+TS). Optimal lattice parameters, with deviations relative to measurements Δa=−0.06 Å, Δb=0.02 Å, and Δc=−0.09 Å, were obtained at the GGA level, which was then used to simulate the sodium trititanate electronic and optical properties. Indirect band transitions have led to a theoretical gap energy value of about 3.25 eV. Our results, however, differ from pioneer DFT results with respect to the specific Brillouin zone vectors for which the indirect transition with smallest energy value occurs. Effective masses for electrons and holes were also estimated along a set of directions in reciprocal space. Lastly, our calculations revealed a relatively large degree of optical isotropy for the Na{sub 2}Ti{sub 3}O{sub 7} optical absorption and complex dielectric function. - Graphical abstract: Monoclinic sodium trititanate Na2Ti3O7 was characterized by experiment and dispersion-corrected DFT calculations. An indirect gap of 3.5 eV is predicted, with heavy electrons and anisotropic holes ruling its conductivity. - Highlights: • Monoclinic Na2Ti3O7 was characterized by experiment (XRD, SEM, UV–Vis spectroscopy). • DFT GGA+TS optimized geometry and

  12. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  13. Large-scale fabrication of linear low density polyethylene/layered double hydroxides composite films with enhanced heat retention, thermal, mechanical, optical and water vapor barrier properties

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Jiazhuo; Zhang, Kun; Zhao, Qinghua [College of Chemistry and Material Science, Shandong Agricultural University, 61 Daizong Street, Tai' an 271018 (China); Wang, Qingguo, E-mail: wqgyyy@126.com [College of Food Science and Engineering, Shandong Agricultural University, 61 Daizong Street, Tai' an 271018 (China); Xu, Jing, E-mail: jiaxu@sdau.edu.cn [College of Chemistry and Material Science, Shandong Agricultural University, 61 Daizong Street, Tai' an 271018 (China)

    2016-11-15

    Novel LDH intercalated with organic aliphatic long-chain anion was large-scale synthesized innovatively by high-energy ball milling in one pot. The linear low density polyethylene (LLDPE)/layered double hydroxides (LDH) composite films with enhanced heat retention, thermal, mechanical, optical and water vapor barrier properties were fabricated by melt blending and blowing process. FT IR, XRD, SEM results show that LDH particles were dispersed uniformly in the LLDPE composite films. Particularly, LLDPE composite film with 1% LDH exhibited the optimal performance among all the composite films with a 60.36% enhancement in the water vapor barrier property and a 45.73 °C increase in the temperature of maximum mass loss rate compared with pure LLDPE film. Furthermore, the improved infrared absorbance (1180–914 cm{sup −1}) of LLDPE/LDH films revealed the significant enhancement of heat retention. Therefore, this study prompts the application of LLDPE/LDH films as agricultural films with superior heat retention. - Graphical abstract: The fabrication process of LLDPE/LDH composite films. - Highlights: • LDH with basal spacing of 4.07 nm was synthesized by high-energy ball milling. • LLDPE composite films with homogeneous LDH dispersion were fabricated. • The properties of LLDPE/LDH composite films were improved. • LLDPE/LDH composite films show superior heat retention property.

  14. Large-scale fabrication of linear low density polyethylene/layered double hydroxides composite films with enhanced heat retention, thermal, mechanical, optical and water vapor barrier properties

    International Nuclear Information System (INIS)

    Xie, Jiazhuo; Zhang, Kun; Zhao, Qinghua; Wang, Qingguo; Xu, Jing

    2016-01-01

    Novel LDH intercalated with organic aliphatic long-chain anion was large-scale synthesized innovatively by high-energy ball milling in one pot. The linear low density polyethylene (LLDPE)/layered double hydroxides (LDH) composite films with enhanced heat retention, thermal, mechanical, optical and water vapor barrier properties were fabricated by melt blending and blowing process. FT IR, XRD, SEM results show that LDH particles were dispersed uniformly in the LLDPE composite films. Particularly, LLDPE composite film with 1% LDH exhibited the optimal performance among all the composite films with a 60.36% enhancement in the water vapor barrier property and a 45.73 °C increase in the temperature of maximum mass loss rate compared with pure LLDPE film. Furthermore, the improved infrared absorbance (1180–914 cm −1 ) of LLDPE/LDH films revealed the significant enhancement of heat retention. Therefore, this study prompts the application of LLDPE/LDH films as agricultural films with superior heat retention. - Graphical abstract: The fabrication process of LLDPE/LDH composite films. - Highlights: • LDH with basal spacing of 4.07 nm was synthesized by high-energy ball milling. • LLDPE composite films with homogeneous LDH dispersion were fabricated. • The properties of LLDPE/LDH composite films were improved. • LLDPE/LDH composite films show superior heat retention property.

  15. Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Attia, M.S., E-mail: Mohamed_sam@yahoo.com [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); Othman, A.M. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt); Youssef, A.O. [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); El-Raghi, E. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt)

    2012-08-15

    This paper reports on a facile technique combined with a simple, sensitive and selective spectrofluorimetric method for the determination of hydrochlorothiazide. In methanol, at pH 8.3 and {lambda}{sub ex}=340, hydrochlorothiazide can remarkably enhance the luminescence intensity of the Eu{sup 3+} ion doped in polymethylmethacrylate polymer (PMMA) matrix. This could be due to the energy transfer from hydrochlorothiazide to Eu{sup 3+} in the excited stated. At the optimized experimental conditions, the enhancement of the characteristic emission band (617 nm) of Eu{sup 3+} ion doped PMMA is directly proportional to the concentration of hydrochlorothiazide with a dynamic range of 5 Multiplication-Sign 10{sup -8}-1.0 Multiplication-Sign 10{sup -5} mol L{sup -1} and detection limit of 8.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. Application of the suggested method was successfully applied to the determination of hydrochlorothiazide in pharmaceutical preparations and human serum samples, with high percentage of recovery, good accuracy and precision. - Highlights: Black-Right-Pointing-Pointer HCT was determined by europium sensitized by HCT in PMMA polymer. Black-Right-Pointing-Pointer Band at 617 nm of Eu{sup 3+} ion ({sup 5}D{sub 0}{yields}{sup 7}F{sub 2}) is sensitive to HCT concentration. Black-Right-Pointing-Pointer Recovery and R.S.D for tablets serum samples in proposed method were calculated. Black-Right-Pointing-Pointer Method is verified for HCT determination in real samples with no interferences.

  16. Alterations of serum cholesterol and serum lipoprotein in breast cancer of women

    OpenAIRE

    Hasija, Kiran; Bagga, Hardeep K.

    2005-01-01

    Fasting blood sample of 50 normal subjects (control) and 100 patients of breast cancer were investigated for serum total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol, very low density lipoprotein, high density lipoprotein cholesterol:low density lipoprotein cholesterol ratio and total cholesterol:high density lipoprotein cholesterol ratio during breast cancer of women. Five cancer stages, types, age groups, parity and menopausal status were undertaken...

  17. Atlas-based head modeling and spatial normalization for high-density diffuse optical tomography: in vivo validation against fMRI.

    Science.gov (United States)

    Ferradal, Silvina L; Eggebrecht, Adam T; Hassanpour, Mahlega; Snyder, Abraham Z; Culver, Joseph P

    2014-01-15

    Diffuse optical imaging (DOI) is increasingly becoming a valuable neuroimaging tool when fMRI is precluded. Recent developments in high-density diffuse optical tomography (HD-DOT) overcome previous limitations of sparse DOI systems, providing improved image quality and brain specificity. These improvements in instrumentation prompt the need for advancements in both i) realistic forward light modeling for accurate HD-DOT image reconstruction, and ii) spatial normalization for voxel-wise comparisons across subjects. Individualized forward light models derived from subject-specific anatomical images provide the optimal inverse solutions, but such modeling may not be feasible in all situations. In the absence of subject-specific anatomical images, atlas-based head models registered to the subject's head using cranial fiducials provide an alternative solution. In addition, a standard atlas is attractive because it defines a common coordinate space in which to compare results across subjects. The question therefore arises as to whether atlas-based forward light modeling ensures adequate HD-DOT image quality at the individual and group level. Herein, we demonstrate the feasibility of using atlas-based forward light modeling and spatial normalization methods. Both techniques are validated using subject-matched HD-DOT and fMRI data sets for visual evoked responses measured in five healthy adult subjects. HD-DOT reconstructions obtained with the registered atlas anatomy (i.e. atlas DOT) had an average localization error of 2.7mm relative to reconstructions obtained with the subject-specific anatomical images (i.e. subject-MRI DOT), and 6.6mm relative to fMRI data. At the group level, the localization error of atlas DOT reconstruction was 4.2mm relative to subject-MRI DOT reconstruction, and 6.1mm relative to fMRI. These results show that atlas-based image reconstruction provides a viable approach to individual head modeling for HD-DOT when anatomical imaging is not available

  18. Densities of carbon foils

    International Nuclear Information System (INIS)

    Stoner, J.O. Jr.

    1991-01-01

    The densities of arc-evaporated carbon target foils have been measured by several methods. The density depends upon the method used to measure it; for the same surface density, values obtained by different measurement techniques may differ by fifty percent or more. The most reliable density measurements are by flotation, yielding a density of 2.01±0.03 g cm -3 , and interferometric step height with the surface density known from auxiliary measurements, yielding a density of 2.61±0.4 g cm -3 . The difference between these density values mayy be due in part to the compressive stresses that carbon films have while still on their substrates, uncertainties in the optical calibration of surface densities of carbon foils, and systematic errors in step-height measurements. Mechanical thickness measurements by micrometer caliper are unreliable due to nonplanarity of these foils. (orig.)

  19. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  20. Coordinate invariance in stochastic singular optics

    CSIR Research Space (South Africa)

    Roux, FS

    2013-11-01

    Full Text Available The study of optical vortices in stochastic optical fields involves various quantities, including the vortex density and topological charge density, that are defined in terms of local expectation values of the distributions of optical vortices...

  1. Below band-gap optical absorption and photoluminescence excitation spectroscopy at room temperature in low-defect-density bulk GaN:Fe

    Czech Academy of Sciences Publication Activity Database

    Gladkov, Petar; Hulicius, Eduard; Paskova, T.; Preble, E.; Evans, K.R.

    2012-01-01

    Roč. 100, č. 3 (2012), "031908-1"-"031908-3" ISSN 0003-6951 Grant - others:US Missile Defense Agency(US) HQ 0147-09-C-0005 Institutional support: RVO:68378271 ; RVO:67985882 Keywords : GaN * spectroscopy * optical absorption Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.794, year: 2012

  2. Absolute and estimated values of macular pigment optical density in young and aged Asian participants with or without age-related macular degeneration.

    Science.gov (United States)

    Ozawa, Yoko; Shigeno, Yuta; Nagai, Norihiro; Suzuki, Misa; Kurihara, Toshihide; Minami, Sakiko; Hirano, Eri; Shinoda, Hajime; Kobayashi, Saori; Tsubota, Kazuo

    2017-08-29

    Lutein and zeaxanthin are suggested micronutrient supplements to prevent the progression of age-related macular degeneration (AMD), a leading cause of blindness worldwide. To monitor the levels of lutein/zeaxanthin in the macula, macular pigment optical density (MPOD) is measured. A commercially available device (MPSII®, Elektron Technology, Switzerland), using technology based on heterochromatic flicker photometry, can measure both absolute and estimated values of MPOD. However, whether the estimated value is applicable to Asian individuals and/or AMD patients remains to be determined. The absolute and estimated values of MPOD were measured using the MPSII® device in 77 participants with a best-corrected visual acuity (BCVA) > 0.099 (logMAR score). The studied eyes included 17 young (20-29 years) healthy, 26 aged (>50 years) healthy, 18 aged and AMD-fellow, and 16 aged AMD eyes. The mean BCVA among the groups were not significantly different. Both absolute and estimated values were measurable in all eyes of young healthy group. However, absolute values were measurable in only 57.7%, 66.7%, and 43.8%, of the aged healthy, AMD-fellow, and AMD groups, respectively, and 56.7% of the eyes included in the 3 aged groups. In contrast, the estimated value was measurable in 84.6%, 88.9% and 93.8% of the groups, respectively, and 88.3% of eyes in the pooled aged group. The estimated value was correlated with absolute value in individuals from all groups by Spearman's correlation coefficient analyses (young healthy: R 2  = 0.885, P = 0.0001; aged healthy: R 2  = 0.765, P = 0.001; AMD-fellow: R 2  = 0.851, P = 0.0001; and AMD: R 2  = 0.860, P = 0.013). Using the estimated value, significantly lower MPOD values were found in aged AMD-related eyes, which included both AMD-fellow and AMD eyes, compared with aged healthy eyes by Student's t-test (P = 0.02). Absolute, in contrast to estimated, value was measurable in a limited number of aged participants

  3. Maternal Serum Lipids in Women with Pre‑eclampsia

    African Journals Online (AJOL)

    total cholesterol, high-density lipoprotein (HDL)-cholesterol, low-density ... higher serum triglyceride levels compared with normal pregnant women (P < 0.01). Other measured .... A positive correlation (r2 = 0.82) was observed between systolic.

  4. The effect of oxide shell thickness on the structural, electronic, and optical properties of Si-SiO{sub 2} core-shell nano-crystals: A (time dependent)density functional theory study

    Energy Technology Data Exchange (ETDEWEB)

    Nazemi, Sanaz, E-mail: s.nazemi@ut.ac.ir, E-mail: pourfath@ut.ac.ir; Soleimani, Ebrahim Asl [School of Electrical and Computer Engineering, University of Tehran, Tehran 14395-515 (Iran, Islamic Republic of); Pourfath, Mahdi, E-mail: s.nazemi@ut.ac.ir, E-mail: pourfath@ut.ac.ir [School of Electrical and Computer Engineering, University of Tehran, Tehran 14395-515 (Iran, Islamic Republic of); Institute for Microelectronics, Technische Universität Wien, Wien A-1040 (Austria); Kosina, Hans [Institute for Microelectronics, Technische Universität Wien, Wien A-1040 (Austria)

    2016-04-14

    Due to their tunable properties, silicon nano-crystals (NC) are currently being investigated. Quantum confinement can generally be employed for size-dependent band-gap tuning at dimensions smaller than the Bohr radius (∼5 nm for silicon). At the nano-meter scale, however, increased surface-to-volume ratio makes the surface effects dominant. Specifically, in Si-SiO{sub 2} core-shell semiconductor NCs the interfacial transition layer causes peculiar electronic and optical properties, because of the co-existence of intermediate oxidation states of silicon (Si{sup n+}, n = 0–4). Due to the presence of the many factors involved, a comprehensive understanding of the optical properties of these NCs has not yet been achieved. In this work, Si-SiO{sub 2} NCs with a diameter of 1.1 nm and covered by amorphous oxide shells with thicknesses between 2.5 and 4.75 Å are comprehensively studied, employing density functional theory calculations. It is shown that with increased oxide shell thickness, the low-energy part of the optical transition spectrum of the NC is red shifted and attenuated. Moreover, the absorption coefficient is increased in the high-energy part of the spectrum which corresponds to SiO{sub 2} transitions. Structural examinations indicate a larger compressive stress on the central silicon cluster with a thicker oxide shell. Examination of the local density of states reveals the migration of frontier molecular orbitals from the oxide shell into the silicon core with the increase of silica shell thickness. The optical and electrical properties are explained through the analysis of the density of states and the spatial distribution of silicon sub-oxide species.

  5. Evolution of the scintillation index and the optical vortex density in speckle fields after removal of the least-squares phase

    CSIR Research Space (South Africa)

    Chen, M

    2010-10-01

    Full Text Available Knowledge of the behavior of stochastic optical fields can aid the understanding of the scintillation of light propagating through a turbulent medium. For this purpose, the authors perform a numerical investigation of the evolution...

  6. Soft optics in intelligent optical networks

    Science.gov (United States)

    Shue, Chikong; Cao, Yang

    2001-10-01

    In addition to the recent advances in Hard-optics that pushes the optical transmission speed, distance, wave density and optical switching capacity, Soft-optics provides the necessary intelligence and control software that reduces operational costs, increase efficiency, and enhances revenue generating services by automating optimal optical circuit placement and restoration, and enabling value-added new services like Optical VPN. This paper describes the advances in 1) Overall Hard-optics and Soft-optics 2) Layered hierarchy of Soft-optics 3) Component of Soft-optics, including hard-optics drivers, Management Soft-optics, Routing Soft-optics and System Soft-optics 4) Key component of Routing and System Soft-optics, namely optical routing and signaling (including UNI/NNI and GMPLS signaling). In summary, the soft-optics on a new generation of OXC's enables Intelligent Optical Networks to provide just-in-time service delivery and fast restoration, and real-time capacity management that eliminates stranded bandwidth. It reduces operational costs and provides new revenue opportunities.

  7. Optical properties of bulk semiconductors and graphene/boron nitride: the Bethe-Salpeter equation with derivative discontinuity-corrected density functional energies

    DEFF Research Database (Denmark)

    Yan, Jun; Jacobsen, Karsten W.; Thygesen, Kristian S.

    2012-01-01

    -dimensional systems of graphene and hexagonal boron-nitride (h-BN) we find good agreement with previous many-body calculations. For the graphene/h-BN interface we find that the fundamental and optical gaps of the h-BN layer are reduced by 2.0 and 0.7 eV, respectively, compared to freestanding h-BN. This reduction......We present an efficient implementation of the Bethe-Salpeter equation (BSE) for optical properties of materials in the projector augmented wave method Grid-based projector-augmented wave method (GPAW). Single-particle energies and wave functions are obtained from the Gritsenko, Leeuwen, Lenthe...

  8. Experimental investigation of gas flow rate and electric field effect on refractive index and electron density distribution of cold atmospheric pressure-plasma by optical method, Moiré deflectometry

    Science.gov (United States)

    Khanzadeh, Mohammad; Jamal, Fatemeh; Shariat, Mahdi

    2018-04-01

    Nowadays, cold atmospheric-pressure (CAP) helium plasma jets are widely used in material processing devices in various industries. Researchers often use indirect and spectrometric methods for measuring the plasma parameters which are very expensive. In this paper, for the first time, characterization of CAP, i.e., finding its parameters such as refractive index and electron density distribution, was carried out using an optical method, Moiré deflectometry. This method is a wave front analysis technique based on geometric optics. The advantages of this method are simplicity, high accuracy, and low cost along with the non-contact, non-destructive, and direct measurement of CAP parameters. This method demonstrates that as the helium gas flow rate decreases, the refractive index increases. Also, we must note that the refractive index is larger in the gas flow consisting of different flow rates of plasma comparing with the gas flow without the plasma.

  9. Gauge-Origin Independent Formulation and Implementation of Magneto-Optical Activity within Atomic-Orbital-Density Based Hartree-Fock and Kohn-Sham Response Theories

    DEFF Research Database (Denmark)

    Kjærgaard, Thomas; Jørgensen, Poul; Thorvaldsen, Andreas

    2009-01-01

    A Lagrangian approach has been used to derive gauge-origin independent expressions for two properties that rationalize magneto-optical activity, namely the Verdet constant V(ω) of the Faraday effect and the B term of magnetic circular dichroism. The approach is expressed in terms of an atomic-orb...

  10. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  11. Lowest excited states and optical absorption spectra of donor–acceptor copolymers for organic photovoltaics: a new picture emerging from tuned long-range corrected density functionals

    KAUST Repository

    Pandey, Laxman; Doiron, Curtis; Sears, John S.; Bré das, Jean-Luc

    2012-01-01

    Polymers with low optical gaps are of importance to the organic photovoltaics community due to their potential for harnessing a large portion of the solar energy spectrum. The combination along their backbones of electron-rich and electron-deficient fragments contributes to the presence of low-lying excited states that are expected to display significant charge-transfer character. While conventional hybrid functionals are known to provide unsatisfactory results for charge-transfer excitations at the time-dependent DFT level, long-range corrected (LRC) functionals have been reported to give improved descriptions in a number of systems. Here, we use such LRC functionals, considering both tuned and default range-separation parameters, to characterize the absorption spectra of low-optical-gap systems of interest. Our results indicate that tuned LRC functionals lead to simulated optical-absorption properties in good agreement with experimental data. Importantly, the lowest-lying excited states (excitons) are shown to present a much more localized nature than initially anticipated. © 2012 the Owner Societies.

  12. Wide-angle imaging LIDAR (WAIL): a ground-based instrument for monitoring the thickness and density of optically thick clouds

    International Nuclear Information System (INIS)

    Love, Steven P.; Davis, A.B.; Rohde, C.A.; Ho, Cheng

    2001-01-01

    Traditional lidar provides little information on dense clouds beyond the range to their base (ceilometry), due to their extreme opacity. At most optical wavelengths, however, laser photons are not absorbed but merely scattered out of the beam, and thus eventually escape the cloud via multiple scattering, producing distinctive extended space- and time-dependent patterns which are, in essence, the cloud's radiative Green functions. These Green functions, essentially 'movies' of the time evolution of the spatial distribution of escaping light, are the primary data products of a new type of lidar: Wide Angle Imaging Lidar (WAIL). WAIL data can be used to infer both optical depth and physical thickness of clouds, and hence the cloud liquid water content. The instrumental challenge is to accommodate a radiance field varying over many orders of magnitude and changing over widely varying time-scales. Our implementation uses a high-speed microchannel plate/crossed delay line imaging detector system with a 60-degree full-angle field of view, and a 532 nm doubled Nd:YAG laser. Nighttime field experiments testing various solutions to this problem show excellent agreement with diffusion theory, and retrievals yield plausible values for the optical and geometrical parameters of the observed cloud decks.

  13. Density functional theory study of the conformation and optical properties of hybrid Au(n)-dithienylethene systems (n = 3, 19, 25).

    Science.gov (United States)

    Fihey, Arnaud; Kloss, Benedikt; Perrier, Aurélie; Maurel, François

    2014-07-03

    We present a theoretical study of Aun-dithienylethene hybrid systems (n = 3, 19, 25), where the organic molecule is covalently linked to a nanometer-scaled gold nanoparticle (NP). We aim at gaining insights on the optical properties of such photochromic devices and proposing a size-limited gold aggregate model able to recover the optical properties of the experimental system. We thus present a DFT-based calculation scheme to model the ground-state (conformation, energetic parameters) and excited-state properties (UV-visible absorption spectra) of this type of hybrid systems. Within this framework, the structural parameters (adsorption site, orientation, and internal structure of the photochrome) are found to be slightly dependent on the size/shape of the gold aggregate. The influence of the gold fragment on the optical properties of the resulting hybrid system is then discussed with the help of TD-DFT combined with an analysis of the virtual orbitals involved in the photochromic transitions. We show that, for the open hybrid isomer, the number of gold atoms is the key parameter to recover the photoactive properties that are experimentally observed. On the contrary, for hybrid closed systems, the three-dimensional structure of the metallic aggregate is of high impact. We thus conclude that Au25 corresponds to the most appropriate fragment to model nanometer-sized NP-DTE hybrid device.

  14. CONFORMATION CHANGES OF HUMAN SERUM γ–GLOBULIN IN THE PRESENCE OF ZINC IONS

    Directory of Open Access Journals (Sweden)

    S. B. Cheknev

    2005-01-01

    Full Text Available Abstract. Conformational changes of human serum γ–globulin during interaction with the zinc ions were studied in a solution. It has been shown that the presence of zinc in over its physiological concentrations led to increase in optical density across the whole spectrum of γ–globulin ultraviolet absorption. On the contrary, hypochromia in the spectrum was registered after interaction of the protein with zinc used in subphisiological concentrations. Possible role of divalent metal cations in changes in conformation of the blood serum γ–globulins, and thereby in regulation of their effector functions was discussed. (Med. Immunol., 2005, vol.7, № 4, pp. 375–380

  15. Protein electrophoresis - serum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003540.htm Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  16. Optical density of states in ultradilute GaAsN alloy: Coexistence of free excitons and impurity band of localized and delocalized states

    Energy Technology Data Exchange (ETDEWEB)

    Bhuyan, Sumi; Pal, Bipul; Bansal, Bhavtosh, E-mail: bhavtosh@iiserkol.ac.in [Indian Institute of Science Education and Research Kolkata, Mohanpur Campus, Nadia 741252, West Bengal (India); Das, Sanat K.; Dhar, Sunanda [Department of Electronic Science, University of Calcutta, 92 A.P.C. Road, Kolkata 700009 (India)

    2014-07-14

    Optically active states in liquid phase epitaxy-grown ultra-dilute GaAsN are studied. The feature-rich low temperature photoluminescence spectrum has contributions from excitonic band states of the GaAsN alloy, and two types of defect states—localized and extended. The degree of delocalization for extended states both within the conduction and defect bands, characterized by the electron temperature, is found to be similar. The degree of localization in the defect band is analyzed by the strength of the phonon replicas. Stronger emission from these localized states is attributed to their giant oscillator strength.

  17. Optical nonlinearity of D-A-π-D and D-A-π-A type of new chalcones for potential applications in optical limiting and density functional theory studies

    Science.gov (United States)

    Chandra Shekhara Shetty, T.; Chidan Kumar, C. S.; Gagan Patel, K. N.; Chia, Tze Shyang; Dharmaprakash, S. M.; Ramasami, Ponnadurai; Umar, Yunusa; Chandraju, Siddegowda; Quah, Ching Kheng

    2017-09-01

    Two new chalcones namely, (2E)-1-(3-fluoro-4-methoxyphenyl)-3-(4-methoxyphenyl) prop-2-en-1-one and (2E)-3-(4-chlorophenyl)-1-(3-fluoro-4-methoxyphenyl)prop-2-en-1-one were synthesized and grown as single crystals by slow evaporation technique in methanol. The FTIR spectrum recorded confirms the presence of functional groups in these materials. The molecular conformation of the compounds was achieved by single crystal X-ray diffraction studies. The thermal stability of the crystals was determined from TGA/DSC curve. The third order optical nonlinearity of the chalcone compounds in DMF solution has been carried out using an Nd:YAG laser at 532 nm as the source of excitation. The nonlinear optical response was characterized by measuring the intensity dependent refractive index n2 of the medium using Z-scan technique. It is seen that the molecules exhibit a negative (defocusing) nonlinearity and large nonlinear refractive index of the order of -1.8 × 10-11 esu. The third-order nonlinearity of the studied chalcones is dominated by nonlinear refraction, which leads to strong optical limiting of laser. The result reveals that these two new chalcone molecules would be a promising material for optical limiting applications. In addition, the optimized molecular geometry, vibrational frequencies in gas, and the Molecular Electrostatic Potential (MEP) surface parameters of the two molecules were calculated using DFT/B3LYP method with 6-311++G(d,p) basis set in ground state. All the theoretical calculations were found in good agreement with experimental data.

  18. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  19. The study of structural, elastic, electronic and optical properties of CsYx I(1 − x(Y = F, Cl, Br using density functional theory

    Directory of Open Access Journals (Sweden)

    Mian Shabeer Ahmad

    2017-04-01

    Full Text Available The structural, electronic, elastic and optical properties of CsYx I(1 − x(Y = F, Cl, Br are investigated using full potential linearized augmented plane wave (FP-LAPW method within the generalized gradient approximation (GGA. The ground state properties such as lattice constant (ao and bulk modulus (K have been calculated. The mechanical properties including Poisson’s ratio (σ, Young’s modulus (E, anisotropy factor (A and shear modulus (G were also calculated. The results of these calculations are comparable with the reported experimental and theoretical values. The ductility of CsYx I(1 − x was analyzed using Pugh’s rule (B/G ratio and Cauchy’s pressure (C12−C44. Our results revealed that CsF is the most ductile among the CsYxI(1 − x(Y = F, Cl, Br compounds. The incremental addition of lighter halogens (Yx slightly weakens the strength of ionic bond in CsYxI(1 − x. Moreover, the optical transitions were found to be direct for binary and ternary CsYxI(1 − x. We hope that this study will be helpful in designing binary and ternary Cs halides for optoelectronic applications.

  20. Determination of bone mineral density of the distal extremity of the radio in Rottweiller, by radiographic optic densitometry;Determinacao da densidade mineral ossea da extremidade distal do radio de caes da raca Rottweiller, por meio da densitometria optica radiografica

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Jefferson Douglas Soares, E-mail: radiologia@unifeob.edu.b [Fundacao de Ensino Octavio Bastos (UNIFEOB), Sao Joao da Boa Vista, SP (Brazil). Fac. de Medicina e Veterinaria; Sterman, Franklin de Almeida [Universidade de Sao Paulo (USP), Butanta, SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia

    2010-06-15

    This study allowed the standardization of the bone mineral density (BMD) of the distal extremity of the radio of 36 dogs adults in Rottweiler breed by radiographic optic densitometry. The limbs of the animals were radiographed with scale of aluminum that served as a reference. The radiographs images were digitalized and analyzed by a computer program for comparison of gray tones between the standard image and the image of the reference scale radiographed with the bone. Afterwards the values of density were expressed in millimeters of aluminum. Also studied the correlations between BMD and the sex, weight and external measures as the length of spine, height of the animal and circumference the distal extremity of the limb in study. The mean values and standard deviations of the bone mineral density of the distal extremity of the radio were: for the metaphyseal region the average of BMD of 7,88+-0,89 mmAl, the diaphyseal region 1 the average of BMD of 8,58+-0,80 mmAl and for diaphyseal region 2 of BMD of 9,00+-0,74 mmAl. (author)

  1. A model for the Lin-Shu type density-wave structure of our Galaxy: Line-of-sight and transverse-longitudinal velocities of 242 optically visible open clusters

    Science.gov (United States)

    Griv, E.; Jiang, I.-G.

    2015-02-01

    In this paper, the fourth in a series, we examine again one of the implications of the Lin-Shu density-wave theory, specifically, the noncircular systematic motion of the Galactic objects. Our previous investigation is extended by analyzing simultaneously both the line-of-sight and transversal velocities of a sample of open clusters for which velocities, distances and ages are available. The ordinary equations of the Oort-Lindblad theory of galactic differential rotation are used. The minor effects caused by the two-dimensional tightly-wound density waves are also taken into account. The published data of 242 currently known optically visible clusters having distances rsight and transversal along the Galactic longitude velocities are nearly equal. We argue that the resemblance of these Galactic wave structures is so remarkable that no doubt is felt as to the theory's truth with respect to these data. The results obtained allow us to conclude that several low-m trailing density-wave patterns with different number of spiral arms m (say, m=1, 2, 3, and 4), pitch angles (about 5o, 8o, 11o, and 14o, respectively) and amplitudes of the perturbed gravitational potential may coexist in the Galaxy. The latter suggests the asymmetric multiarm, not well-organized (``flocculent'') spiral structure of the system. In memory of Professors Alexei M. Fridman (1940-2010) and Chi Yuan (1937-2008)

  2. Road density

    Data.gov (United States)

    U.S. Environmental Protection Agency — Road density is generally highly correlated with amount of developed land cover. High road densities usually indicate high levels of ecological disturbance. More...

  3. Activation of lipoprotein lipase by lipoprotein fractions of human serum.

    Science.gov (United States)

    Bier, D M; Havel, R J

    1970-11-01

    Triglycerides in fat emulsions are hydrolyzed by lipoprotein lipase only when they are "activated" by serum lipoproteins. The contribution of different lipoprotein fractions to hydrolysis of triglycerides in soybean oil emulsion was assessed by determining the quantity of lipoprotein fraction required to give half-maximal hydrolysis. Most of the activator property of whole serum from normolipidemic, postabsorptive subjects was in high density lipoproteins. Low density lipoproteins and serum from which all lipoprotein classes were removed had little or no activity. Also, little activator was present in guinea pig serum or in very low density poor serum from an individual with lecithin:cholesterol acyltransferase deficiency, both of which are deficient in high density lipoproteins. Human very low density lipoproteins are potent activators and are much more active than predicted from their content of high density lipoprotein-protein. Per unit weight of protein, very low density lipoproteins had 13 times the activity of high density lipoproteins. These observations suggest that one or more of the major apoproteins of very low density lipoproteins, present as a minor constituent of high density lipoproteins, may be required for the activation process.

  4. The relation between serum visfatin levels and cardiovascular ...

    African Journals Online (AJOL)

    Abir Naguib

    2011-08-15

    Aug 15, 2011 ... HDL, high density lipoproteins; LDL, low density lipoproteins; RS, ... triglycerides and CACS (P = 0.014); however, there was no significant correlation of the CACS with the visfatin .... included total cholesterol (TC), high and low density lipopro-. 118 ... None of the studied patients had elevated serum TG.

  5. The -250G>A promoter variant in hepatic lipase associates with elevated fasting serum high-density lipoprotein cholesterol modulated by interaction with physical activity in a study of 16,156 Danish subjects

    DEFF Research Database (Denmark)

    Grarup, Niels; Andreasen, Camilla H; Andersen, Mette K

    2008-01-01

    -tolerant control subjects (n = 360). RESULTS: In the Inter99 study, the A allele of rs2070895 associated with a 0.057 mmol/liter [95% confidence interval (CI) 0.039-0.075] increase in fasting serum HDL-cholesterol (HDL-c) (P = 8 x 10(-10)) supported by association in the Anglo-Danish-Dutch Study of Intensive...... Treatment in People with Screen Detected Diabetes in Primary Care study [0.038 mmol/liter per allele (95% CI 0.024-0.053); P = 2 x 10(-7)). The allelic effect on HDL-c was modulated by interaction with self-reported physical activity (P(interaction) = 0.002) because vigorous physically active homozygous A...... of variants in LIPC on metabolic traits and type 2 diabetes in a large sample of Danes. Because behavioral factors influence hepatic lipase activity, we furthermore examined possible gene-environment interactions in the population-based Inter99 study. DESIGN: The LIPC -250G>A (rs2070895) variant was genotyped...

  6. The effects of menopause on the serum lipid profile of normal ...

    African Journals Online (AJOL)

    Serum total cholesterol and their subfractions- high-density lipoproteins (HDL), low-density lipoproteins (LDL), very low-density lipoproteins (VLDL) and triglycerides (TG) were estimated using enzymatic and established mathematical methods. There was no significant difference in the total serum cholesterol and triglyceride ...

  7. The relation between serum lipids and lutein and zeaxanthin in the serum and retina: results from cross-sectional, case-control and case study designs

    Directory of Open Access Journals (Sweden)

    Renzi Lisa M

    2012-02-01

    Full Text Available Abstract Background The xanthophyll carotenoids lutein (L and zeaxanthin (Z are found in and around the macula of the primate retina, where they are termed macular pigment (MP. Dietary L and Z are absorbed with fat in the gut and transported on lipoproteins to the retina. Both MP and serum lipoproteins have been related to risk for neurodegenerative diseases such as age-related macular degeneration (AMD. L and Z are carried on both HDL (related to reduced risk of AMD and LDL (related to increased risk. The purpose of this set of studies was to analyze the relation between L and Z in the serum and retina with the circulating lipid profile. Methods In all experiments, lipoproteins were measured enzymatically from plasma, and MP optical density (MPOD was measured using customized heterochromatic flicker photometry. Experiment 1: Relations between serum L and Z, MPOD and lipoprotein levels. 108 young, healthy subjects (M = 23.2, SD = 4.12 years participated. Lipoprotein levels and MPOD were measured. In a subset of 66 participants, serum L and Z levels were also measured using high-performance liquid chromatography. Experiment 2: Relations between lipoprotein levels and MPOD in statin users. 20 subjects (M = 58.05, SD = 11.08 years taking statin medication and 20 subjects (M = 57.95, SD = 11.03 years not taking satin were recruited for participation. MPOD and lipoprotein levels were measured. Experiment 3: lowering lipoprotein levels to impact MPOD. One individual (aged 41 years with high MP density adhered first to an atorvastatin regimen, then, after a wash-out period, to a rosuvastatin regimen. Results Experiment 1: HDL were significantly (p r = 0.33, to serum L (r = 0.36 and to serum Z (r = 0.26. MPOD was also significantly related to total cholesterol (r = 0.19. Experiment 2: MPOD was not lower in statin users when compared to matched non-statin users, but MPOD decreased significantly with increased duration of statin use (r = −0

  8. Molecular structure, chemical reactivity, nonlinear optical activity and vibrational spectroscopic studies on 6-(4-n-heptyloxybenzyoloxy)-2-hydroxybenzylidene)amino)-2H-chromen-2-one: A combined density functional theory and experimental approach

    Science.gov (United States)

    Pegu, David; Deb, Jyotirmoy; Saha, Sandip Kumar; Paul, Manoj Kumar; Sarkar, Utpal

    2018-05-01

    In this work, we have synthesized new coumarin Schiff base molecule, viz., 6-(4-n-heptyloxybenzyoloxy)-2-hydroxybenzylidene)amino)-2H-chromen-2-one and characterized its structural, electronic and spectroscopic properties experimentally and theoretically. The theoretical analysis of UV-visible absorption spectra reflects a red shift in the absorption maximum in comparison to the experimental results. Most of the vibrational assignments of infrared and Raman spectra predicted using density functional theory approach match well with the experimental findings. Further, the chemical reactivity analysis confirms that solvent highly affects the reactivity of the studied compound. The large hyperpolarizability value of the compound concludes that the system exhibits significant nonlinear optical features and thus, points out their possibility in designing material with high nonlinear activity.

  9. Measurement of nucleation site density, bubble departure diameter and frequency in pool boiling of water using high-speed infrared and optical cameras

    Energy Technology Data Exchange (ETDEWEB)

    Gerardi, Craig; Buongiorno, Jacopo; Hu, Lin-wen; McKrell, Thomas [Massachusetts Institute of Technology, Cambridge, MA (United States)], e-mail: jacopo@mit.edu

    2009-07-01

    A high-speed video and IR thermometry based technique has been used to obtain time and space resolved information on bubble nucleation and boiling heat transfer. This approach provides a fundamental and systematic method for investigating nucleate boiling in a very detailed fashion. Data on bubble departure diameter and frequency, growth and wait times, and nucleation site density are measured with relative ease. The data have been compared to the traditional decades-old and poorly-validated nucleate-boiling models and correlations. The agreement between the data and the models is relatively good. This study also shows that new insights into boiling heat transfer mechanisms can be obtained with the present technique. For example, our data and analysis suggest that a large contribution to bubble growth comes from heat transfer through the superheated liquid layer in addition to micro layer evaporation. (author)

  10. Time-dependent broken-symmetry density functional theory simulation of the optical response of entangled paramagnetic defects: Color centers in lithium fluoride

    Science.gov (United States)

    Janesko, Benjamin G.

    2018-02-01

    Parameter-free atomistic simulations of entangled solid-state paramagnetic defects may aid in the rational design of devices for quantum information science. This work applies time-dependent density functional theory (TDDFT) embedded-cluster simulations to a prototype entangled-defect system, namely two adjacent singlet-coupled F color centers in lithium fluoride. TDDFT calculations accurately reproduce the experimental visible absorption of both isolated and coupled F centers. The most accurate results are obtained by combining spin symmetry breaking to simulate strong correlation, a large fraction of exact (Hartree-Fock-like) exchange to minimize the defect electrons' self-interaction error, and a standard semilocal approximation for dynamical correlations between the defect electrons and the surrounding ionic lattice. These results motivate application of two-reference correlated ab initio approximations to the M-center, and application of TDDFT in parameter-free simulations of more complex entangled paramagnetic defect architectures.

  11. Normal co-ordinate analysis, molecular structural, non-linear optical, second order perturbation studies of Tizanidine by density functional theory.

    Science.gov (United States)

    Sheela, N R; Muthu, S; Sampathkrishnan, S; Al-Saadi, Abdulaziz A

    2015-03-15

    The spectroscopic techniques and semi-empirical molecular calculations have been utilized to analyze the drug Tizanidine (5CDIBTA). The solid phase Fourier Transform Infrared (FTIR) and Fourier Transform Raman (FTR) spectral analysis of 5CDIBTA is carried out along with density functional theory (DFT) calculations (B3LYP) with the 6-311++G(d,p) basis set. Detailed interpretation of the vibrational spectra of the compound has been made on the basis of the calculated potential energy distribution (PED). The individual atomic charges by NPA using B3LYP method is studied. A study on the Mulliken atomic charges, frontier molecular orbitals (HOMO-LUMO), molecular electrostatic potential (MEP) and thermodynamic properties were performed. The electric dipole moment (μ) and the first hyperpolarizability (α) values of the investigated molecule were also computed. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Measurement of nucleation site density, bubble departure diameter and frequency in pool boiling of water using high-speed infrared and optical cameras

    International Nuclear Information System (INIS)

    Gerardi, Craig; Buongiorno, Jacopo; Hu, Lin-wen; McKrell, Thomas

    2009-01-01

    A high-speed video and IR thermometry based technique has been used to obtain time and space resolved information on bubble nucleation and boiling heat transfer. This approach provides a fundamental and systematic method for investigating nucleate boiling in a very detailed fashion. Data on bubble departure diameter and frequency, growth and wait times, and nucleation site density are measured with relative ease. The data have been compared to the traditional decades-old and poorly-validated nucleate-boiling models and correlations. The agreement between the data and the models is relatively good. This study also shows that new insights into boiling heat transfer mechanisms can be obtained with the present technique. For example, our data and analysis suggest that a large contribution to bubble growth comes from heat transfer through the superheated liquid layer in addition to micro layer evaporation. (author)

  13. Consuming a hypocaloric high fat low carbohydrate diet for 12 weeks lowers C-reactive protein, and raises serum adiponectin and high density lipoprotein-cholesterol in obese subjects.

    Science.gov (United States)

    Ruth, Megan R; Port, Ava M; Shah, Mitali; Bourland, Ashley C; Istfan, Nawfal W; Nelson, Kerrie P; Gokce, Noyan; Apovian, Caroline M

    2013-12-01

    High fat, low carbohydrate (HFLC) diets have become popular tools for weight management. We sought to determine the effects of a HFLC diet compared to a low fat high carbohydrate (LFHC) diet on the change in weight loss, cardiovascular risk factors and inflammation in subjects with obesity. Obese subjects (29.0-44.6 kg/m2) recruited from Boston Medical Center were randomized to a hypocaloric LFHC (n=26) or HFLC (n=29) diet for 12 weeks. The age range of subjects was 21-62 years. As a percentage of daily calories, the HFLC group consumed 33.5% protein, 56.0% fat and 9.6% carbohydrate and the LFHC group consumed 22.0% protein, 25.0% fat and 55.7% carbohydrate. The change in percent body weight, lean and fat mass, blood pressure, flow mediated dilation, hip:waist ratio, hemoglobin A1C, fasting insulin and glucose, and glucose and insulin response to a 2h oral glucose tolerance test did not differ (P>0.05) between diets after 12 weeks. The HFLC group had greater mean decreases in serum triglyceride (P=0.07), and hs-CRP (P=0.03), and greater mean increases in HDL cholesterol (P=0.004), and total adiponectin (P=0.045) relative to the LFHC. Secreted adipose tissue adiponectin or TNF-α did not differ after weight loss for either diet. Relative to the LFHC group, the HFLC group had greater improvements in blood lipids and systemic inflammation with similar changes in body weight and composition. This small-scale study suggests that HFLC diets may be more beneficial to cardiovascular health and inflammation in free-living obese adults compared to LFHC diets. © 2013.

  14. Statistical optics

    Science.gov (United States)

    Goodman, J. W.

    This book is based on the thesis that some training in the area of statistical optics should be included as a standard part of any advanced optics curriculum. Random variables are discussed, taking into account definitions of probability and random variables, distribution functions and density functions, an extension to two or more random variables, statistical averages, transformations of random variables, sums of real random variables, Gaussian random variables, complex-valued random variables, and random phasor sums. Other subjects examined are related to random processes, some first-order properties of light waves, the coherence of optical waves, some problems involving high-order coherence, effects of partial coherence on imaging systems, imaging in the presence of randomly inhomogeneous media, and fundamental limits in photoelectric detection of light. Attention is given to deterministic versus statistical phenomena and models, the Fourier transform, and the fourth-order moment of the spectrum of a detected speckle image.

  15. Physico-chemical characterization, density functional theory (DFT) studies and Hirshfeld surface analysis of a new organic optical material: 1H-benzo[d]imidazol-3-ium-2,4,6-trinitrobenzene-1,3 bis(olate)

    Science.gov (United States)

    Dhamodharan, P.; Sathya, K.; Dhandapani, M.

    2017-10-01

    A novel organic crystal, 1H-benzo[d]imidazol-3-ium-2,4,6-trinitrobenzene-1,3 bis(olate) (BITB), was synthesized. Single crystals of BITB were harvested by solution growth-slow evaporation technique. 1H and 13C NMR spectroscopic techniques were utilized to confirm the presence of various types of carbons and protons in BITB. Single crystal XRD confirms that BITB crystallizes in monoclinic system with a space group of P21/n. The suitability of this material for optical applications was assessed by optical absorption, transmittance, reflectance and refractive index spectroscopic techniques. Gaussian 09 program at B3LYP/6-311++G(d,p) level of basis set as used for the optimization of molecular structure of BITB. Greater first order hyperpolarizability value of BITB is due to intensive hydrogen bond network in the crystal. The value is 15 times greater than that of Urea, a reference standard. Computation of frontier molecular orbitals and electrostatic potential surface helped to understand the electron density and reactive sites in BITB. The material was thermally stable up to 220 °C. Hirshfeld surface analysis was performed to quantify the covalent and non covalent interactions.

  16. Lung density

    DEFF Research Database (Denmark)

    Garnett, E S; Webber, C E; Coates, G

    1977-01-01

    The density of a defined volume of the human lung can be measured in vivo by a new noninvasive technique. A beam of gamma-rays is directed at the lung and, by measuring the scattered gamma-rays, lung density is calculated. The density in the lower lobe of the right lung in normal man during quiet...... breathing in the sitting position ranged from 0.25 to 0.37 g.cm-3. Subnormal values were found in patients with emphsema. In patients with pulmonary congestion and edema, lung density values ranged from 0.33 to 0.93 g.cm-3. The lung density measurement correlated well with the findings in chest radiographs...... but the lung density values were more sensitive indices. This was particularly evident in serial observations of individual patients....

  17. Investigation of genetic variation in scavenger receptor class B, member 1 (SCARB1) and association with serum carotenoids

    Science.gov (United States)

    McKay, Gareth J; Loane, Edward; Nolan, John M; Patterson, Christopher C; Meyers, Kristin J; Mares, Julie A; Yonova-Doing, Ekaterina; Hammond, Christopher J; Beatty, Stephen; Silvestri, Giuliana

    2013-01-01

    Objective To investigate association of scavenger receptor class B, member 1 (SCARB1) genetic variants with serum carotenoid levels of lutein (L) and zeaxanthin (Z) and macular pigment optical density (MPOD). Design A cross-sectional study of healthy adults aged 20-70. Participants 302 participants recruited following local advertisement. Methods MPOD was measured by customized heterochromatic flicker photometry. Fasting blood samples were taken for serum L and Z measurement by HPLC and lipoprotein analysis by spectrophotometric assay. Forty-seven single nucleotide polymorphisms (SNPs) across SCARB1 were genotyped using Sequenom technology. Association analyses were performed using PLINK to compare allele and haplotype means, with adjustment for potential confounding and correction for multiple comparisons by permutation testing. Replication analysis was performed in the TwinsUK and CAREDS cohorts. Main outcome measures Odds ratios (ORs) for macular pigment optical density area, serum lutein and zeaxanthin concentrations associated with genetic variations in SCARB1 and interactions between SCARB1 and sex. Results Following multiple regression analysis with adjustment for age, body mass index, sex, high-density lipoprotein cholesterol (HDLc), low-density lipoprotein cholesterol (LDLc), triglycerides, smoking, dietary L and Z levels, 5 SNPs were significantly associated with serum L concentration and 1 SNP with MPOD (P<0.01). Only the association between rs11057841 and serum L withstood correction for multiple comparisons by permutation testing (P<0.01) and replicated in the TwinsUK cohort (P=0.014). Independent replication was also observed in the CAREDS cohort with rs10846744 (P=2×10−4), a SNP in high linkage disequilibrium with rs11057841 (r2=0.93). No significant interactions by sex were found. Haplotype analysis revealed no stronger association than obtained with single SNP analyses. Conclusions Our study has identified association between rs11057841 and

  18. Photoabsorption of Acridine Yellow and Proflavin Bound to Human Serum Albumin Studied by Means of Quantum Mechanics/Molecular Dynamics

    DEFF Research Database (Denmark)

    Aidas, Kestutis; Olsen, Jógvan Magnus Haugaard; Kongsted, Jacob

    2013-01-01

    Attempting to unravel mechanisms in optical probing of proteins, we have performed pilot calculations of two cationic chromophores—acridine yellow and proflavin—located at different binding sites within human serum albumin, including the two primary drug binding sites as well as a heme binding site....... The computational scheme adopted involves classical molecular dynamics simulations of the ligands bound to the protein and subsequent linear response polarizable embedding density functional theory calculations of the excitation energies. A polarizable embedding potential consisting of point charges fitted...

  19. Effect of wood flour content on the optical color, surface chemistry, mechanical and morphological properties of wood flour/recycled high density polyethylene (rHDPE) composite

    Science.gov (United States)

    Sheng, Chan Kok; Amin, Khairul Anuar Mat; Kee, Kwa Bee; Hassan, Mohd Faiz; Ali, E. Ghapur E.

    2018-05-01

    In this study, effect of wood flour content on the color, surface chemistry, mechanical properties and surface morphology of wood-plastic composite (WPC) on different mixture ratios of recycled high density polyethylene (rHDPE) and wood flour were investigated in detail. The presence of wood flour in the composite indicates a significant total color change and a decrease of lightness. Functional groups of wood flour in WPC can be seen clearer from the Fourier transform infrared (FTIR) spectra as the wood flour content increases. The mechanical tensile testing shows that the tensile strength of Young's modulus is improved, whereas the strain and elongation at break were reduced by the addition of wood flour. The gap between the wood flour microvoid fibre and rHDPE matrix becomes closer when the wood flour content is increased as observed by scanning electron microscope (SEM) image. This finding implies a significant improvement on the interaction of interfacial adhesion between the rHDPE matrix and wood flour filler in the present WPC.

  20. Serum low-density lipoprotein cholesterol level is strong risk factor for acquired color vision impairment in young to middle-aged Japanese men: the Okubo Color Study Report 2.

    Science.gov (United States)

    Shoji, Takuhei; Sakurai, Yutaka; Sato, Hiroki; Chihara, Etsuo; Ishida, Masahiro; Omae, Kazuyuki

    2010-06-01

    To investigate associations between blood low-density lipoprotein cholesterol (LDL-C) levels and the prevalence of acquired color vision impairment (ACVI) in middle-aged Japanese men. Participants in this cross-sectional study underwent color vision testing, ophthalmic examination, a standardized interview and examination of venous blood samples. Ishihara plates, a Lanthony 15-hue desaturated panel, and Standard pseudoisochromatic Plates part 2 were used to examine color vision ability. The Farnsworth-Munsell 100-hue test was performed to define ACVI. Smoking status and alcohol intake were recorded during the interview. We performed logistic regression analysis adjusted for age, LDL-C level, systemic hypertension, diabetes, cataract, glaucoma, overweight, smoking status, and alcohol intake. Adjusted odds ratios for four LDL-C levels were calculated. A total of 1042 men were enrolled, 872 participants were eligible for the study, and 31 subjects were diagnosed with ACVI. As compared to the lowest LDL-C category level (or=160 mg/dl). The multiple-adjusted ORs were 2.91 (95% CI, 0.87-9.70) for the 2nd highest category and 3.81 (95% CI, 1.03-14.05) for the highest level. Tests for trend were significant (Pmen with elevated LDL-C levels. These changes might be related to deteriorated neurologic function associated with lipid metabolite abnormalities. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  1. Optical materials

    International Nuclear Information System (INIS)

    Poker, D.B.; Ortiz, C.

    1989-01-01

    This book reports on: Diamond films, Synthesis of optical materials, Structure related optical properties, Radiation effects in optical materials, Characterization of optical materials, Deposition of optical thin films, and Optical fibers and waveguides

  2. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  3. Dietary modification of human macular pigment density.

    Science.gov (United States)

    Hammond, B R; Johnson, E J; Russell, R M; Krinsky, N I; Yeum, K J; Edwards, R B; Snodderly, D M

    1997-08-01

    The retinal carotenoids lutein (L) and zeaxanthin (Z) that form the macular pigment (MP) may help to prevent neovascular age-related macular degeneration. The purpose of this study was to determine whether MP density in the retina could be raised by increasing dietary intake of L and Z from foods. Macular pigment was measured psychophysically for 13 subjects. Serum concentrations of L, Z, and beta-carotene were measured by high-performance liquid chromatography. Eleven subjects modified their usual daily diets by adding 60 g of spinach (10.8 mg L, 0.3 mg Z, 5 mg beta-carotene) and ten also added 150 g of corn (0.3 mg Z, 0.4 mg L); two other subjects were given only corn. Dietary modification lasted up to 15 weeks. For the subjects fed spinach or spinach and corn, three types of responses to dietary modification were identified: Eight "retinal responders" had increases in serum L (mean, 33%; SD, 22%) and in MP density (mean, 19%; SD, 11%); two "retinal nonresponders" showed substantial increases in serum L (mean, 31%) but not in MP density (mean, -11%); one "serum and retinal nonresponder" showed no changes in serum L, Z, or beta-carotene and no change in MP density. For the two subjects given only corn, serum L changed little (+11%, -6%), but in one subject serum Z increased (70%) and MP density increased (25%). Increases in MP density were obtained within 4 weeks of dietary modification for most, but not all, subjects. When MP density increased with dietary modification, it remained elevated for at least several months after resuming an unmodified diet. Augmentation of MP for both experimental and clinical investigation appears to be feasible for many persons.

  4. Embryogenesis-promoting factors in rat serum.

    Science.gov (United States)

    Katoh, M; Kimura, R; Shoji, R

    1998-06-15

    Regarding whole rat embryo cultures in vitro, rat serum as a culture medium is known to support the normal growth of rat embryos in the organogenesis phase. The purpose of the present study was to isolate the embryogenesis-promoting factors from rat serum as a first step in the development of a defined serum-free medium for a whole embryo culture system. Pooled rat serum after heat inactivation was fractionated into three major peaks (frA, containing a region of void volume, frB, and frC) by gel filtration. The 9.5-day rat embryos that were cultivated for 48 hr in essential salt medium containing frB (with a molecular size range of 100-500 kDa) revealed normal growth. Three proteins (27 kDa, 76 kDa, and 190 kDa) that had the embryogenesis-promoting effects were isolated from 3-hr delayed centrifuged rat serum by the ion exchange chromatography. The 76-kDa protein was found to be rat transferrin by immunoblotting. The 27-kDa protein was identified as apo-AI (the major apoprotein of high-density lipoprotein) by immunoblotting. High-density lipoprotein obtained from pooled rat serum by a NaBr density gradient ultracentrifugation was found to have a positive effect on embryogenesis. The 10-kDa protein was also identified as alpha 1-inhibitor 3 by immunoblotting. In addition, the embryogenesis-promoting effect of the fraction containing 27-kDa and 190-kDa proteins declined within a short period of storage at -20 degrees C. This decrease was countered by supplementing its fraction (D-2) with albumin isolated from rat serum. These results in the present study suggest that transferrin, high-density lipoprotein, and alpha 1-inhibitor 3 in rat serum may be embryogenesis-promoting factors, and that albumin appeared to play a role in the embryogenesis of rat embryos in whole embryo cultures.

  5. Low Bone Density

    Science.gov (United States)

    ... Density Exam/Testing › Low Bone Density Low Bone Density Low bone density is when your bone density ... people with normal bone density. Detecting Low Bone Density A bone density test will determine whether you ...

  6. Electronic and optical properties of the SiB{sub 2}O{sub 4} (B=Mg, Zn, and Cd) spinel oxides: An ab initio study with the Tran–Blaha-modified Becke–Johnson density functional

    Energy Technology Data Exchange (ETDEWEB)

    Allali, D. [Laboratory for Developing New Materials and their Characterization, University of Setif 1, 19000 Setif (Algeria); Bouhemadou, A., E-mail: a_bouhemadou@yahoo.fr [Laboratory for Developing New Materials and their Characterization, University of Setif 1, 19000 Setif (Algeria); Safi, E. Muhammad Abud Al [Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Bin-Omran, S. [Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Department of Physics, Faculty of Science and Humanitarian Studies, Salman Bin Abdalaziz University, Alkharj 11942 (Saudi Arabia); Chegaar, M. [Department of Physics, Faculty of Science, University of Setif 1, 19000 Setif (Algeria); Khenata, R. [Laboratoire de Physique Quantique et de Modélisation Mathématique (LPQ3M), Département de Technologie, Université de Mascara, 29000 Mascara (Algeria); Reshak, A.H. [New Technologies-Research Center, University of West Bohemia, Univerzitni 8, 306 14 Pilson (Czech Republic); Center of Excellence Geopolymer and Green Technology, School of Material Engineering, University Malaysia Perlis, 01007 Kangar, Perlis (Malaysia)

    2014-06-15

    We report ab initio density functional theory calculations of the structural, electronic and optical properties of the spinel oxides SiMg{sub 2}O{sub 4}, SiZng{sub 2}O{sub 4}, and SiCd{sub 2}O{sub 4} using the full-potential linearized augmented plane-wave method. The structural parameters calculated using both the local density and generalized gradient approximations to the exchange-correlation potential are consistent with the literature data. To calculate the electronic properties, the exchange-correlation potential is treated with various functionals, and we find that the newly developed Tran–Blaha-modified Becke–Johnson functional significantly improves the band gap. We predict a direct band gap in all of the considered SiB{sub 2}O{sub 4} compounds, and the band gaps continuously decrease as the atomic size of the B element increases. The decrease in the fundamental direct band gap (Γ–Γ) from SiMg{sub 2}O{sub 4} to SiZn{sub 2}O{sub 4} to SiCd{sub 2}O{sub 4} can be attributed to p–d mixing in the upper valence bands of SiZn{sub 2}O{sub 4} and SiCd{sub 2}O{sub 4}. The lowest conduction band is well dispersive, similar to that found for transparent conducting oxides such as ZnO. This band is mainly defined by the s and p electrons of the Si and B (B=Mg, Zn, Cd) atoms. The topmost valence band is considerably less dispersive and is defined by O-2p and B–d electrons. The charge-carrier effective masses are evaluated at the topmost valence band and at the bottommost conduction band that were calculated. The frequency-dependent complex dielectric function, absorption coefficient, refractive index, extinction coefficient, reflectivity and electron energy loss function were estimated. We find that the value of the zero-frequency limit of the dielectric function ε(0) increases as the band gap decreases. The origins of the peaks and structures in the optical spectra are determined in terms of the calculated energy band structures.

  7. The concentrations of clinafloxacin in alveolar macrophages, epithelial lining fluid, bronchial mucosa and serum after administration of single 200 mg oral doses to patients undergoing fibre-optic bronchoscopy.

    Science.gov (United States)

    Honeybourne, D; Andrews, J M; Cunningham, B; Jevons, G; Wise, R

    1999-01-01

    The concentrations of clinafloxacin were measured in serum, bronchial mucosa, alveolar macrophages and epithelial lining fluid after single 200 mg oral doses of clinafloxacin had been administered to 15 subjects who were undergoing bronchoscopy. Concentrations were measured using a microbiological assay method. Mean concentrations in serum, bronchial mucosa, alveolar macrophages and epithelial lining fluid at a mean of 1.27 h post-dose were 1.54, 2.65, 15.60 and 2.71 mg/L respectively. These site concentrations exceeded the MIC90 for common respiratory pathogens and indicate that clinafloxacin is likely to be effective in the treatment of a wide range of respiratory tract infections.

  8. Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples

    Directory of Open Access Journals (Sweden)

    Samira Moraes Cunha de Mesquita

    2015-06-01

    Full Text Available ABSTRACT. Mesquita S.M.C., Mansur F.J., Nascimento E.R., Barreto M.L. & Kimura L.M.S. [Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples.] Padroniza- ção e aplicação de ELISA indireto para diagnóstico de Mycoplasma bovis em amostras de soro sanguíneo bovino. Revista Brasileira de Medicina Veterinária, 37(2:101-107, 2015. Universidade Federal Fluminense, Faculdade de Veteriná- ria, Rua Vital Brazil Filho, 64, Vital Brazil, Niterói, RJ 24230-340, Brasil. E-mail: samira.veterinaria@gmail.com International researchers presented results indicating frequent involvement of Mycoplasma spp. as a causative agent of mastitis in cattle, associating its presence with significant economic losses to farmers. Mycoplasma bovis is the species most reported and relevant, because it causes more severe disease. The level of antibodies against M. bovis remains high for several months and can be detected by ELISA. The aim of this work was to develop an indirect ELISA with whole cell antigen of M. bovis (strain Donetta PG 45 with subsequent application in bovine blood serum samples for detection of antibodies against M. bovis. The immunization of cows A and B by inoculating an immunogen against M. bovis to obtain hyperimmune blood serum was the first stage of this work, then the stage of standardization of ELISA was proceeded. The concentration of 2 mg of antigen/mL for coating the microtiter plates was decided by statistical analyses. The optical density value 0,2 was determined as the limit of reactivity discrimination of samples (the cut-off point. The hyperimmune blood serum sample of the cow A (collected 30 days after immunization was chosen as the positive control and, the fetal calf serum was chosen as negative control of the assay. In addition, the ideal optimal dilutions found for blood serum samples was 1:400 and for conjugate was 1:10.000 and the substrate used was the ortho

  9. Modifiable risk factors promoting neurodegeneration is associated with two novel brain degradation markers measured in serum

    DEFF Research Database (Denmark)

    Neergaard, Jesper; Møller, Katrine Dragsbæk; Christiansen, Claus

    2017-01-01

    truncated tau fragments (Tau-A and Tau-C) in serum. Platelets, albumin and several modifiable risk factors, including Body Mass Index, high density lipoprotein and White Blood Cell count were associated with the serum level of tau fragments. The factors associated with tau in serum may promote...

  10. Lower Serum Paraoxonase-1 Activity Is Related to Higher Serum Amyloid A Levels in Metabolic Syndrome

    NARCIS (Netherlands)

    Kappelle, Paul Jan Willem Herman; Bijzet, Johan; Hazenberg, Bouke Pier; Dullaart, Robin Pieter Frank

    Background and Aims. High-density lipoproteins (HDL) contain the anti-oxidative enzyme, paraoxonase-1 (PON-1), which is important for atheroprotection. The acute phase reactant, serum amyloid A (SAA), an HDL-associated apolipoprotein, may impair PON-1 activity, whereas SAA and PON-1 are reciprocally

  11. Level densities

    International Nuclear Information System (INIS)

    Ignatyuk, A.V.

    1998-01-01

    For any applications of the statistical theory of nuclear reactions it is very important to obtain the parameters of the level density description from the reliable experimental data. The cumulative numbers of low-lying levels and the average spacings between neutron resonances are usually used as such data. The level density parameters fitted to such data are compiled in the RIPL Starter File for the tree models most frequently used in practical calculations: i) For the Gilber-Cameron model the parameters of the Beijing group, based on a rather recent compilations of the neutron resonance and low-lying level densities and included into the beijing-gc.dat file, are chosen as recommended. As alternative versions the parameters provided by other groups are given into the files: jaeri-gc.dat, bombay-gc.dat, obninsk-gc.dat. Additionally the iljinov-gc.dat, and mengoni-gc.dat files include sets of the level density parameters that take into account the damping of shell effects at high energies. ii) For the backed-shifted Fermi gas model the beijing-bs.dat file is selected as the recommended one. Alternative parameters of the Obninsk group are given in the obninsk-bs.dat file and those of Bombay in bombay-bs.dat. iii) For the generalized superfluid model the Obninsk group parameters included into the obninsk-bcs.dat file are chosen as recommended ones and the beijing-bcs.dat file is included as an alternative set of parameters. iv) For the microscopic approach to the level densities the files are: obninsk-micro.for -FORTRAN 77 source for the microscopical statistical level density code developed in Obninsk by Ignatyuk and coworkers, moller-levels.gz - Moeller single-particle level and ground state deformation data base, moller-levels.for -retrieval code for Moeller single-particle level scheme. (author)

  12. Determination of the absolute configurations of natural products via density functional theory calculations of optical rotation, electronic circular dichroism, and vibrational circular dichroism: the cytotoxic sesquiterpene natural products quadrone, suberosenone, suberosanone, and suberosenol A acetate.

    Science.gov (United States)

    Stephens, P J; McCann, D M; Devlin, F J; Smith, A B

    2006-07-01

    The determination of the absolute configurations (ACs) of chiral molecules using the chiroptical techniques of optical rotation (OR), electronic circular dichroism (ECD), and vibrational circular dichroism (VCD) has been revolutionized by the development of density functional theory (DFT) methods for the prediction of these properties. Here, we demonstrate the significance of these advances for the stereochemical characterization of natural products. Time-dependent DFT (TDDFT) calculations of the specific rotations, [alpha](D), of four cytotoxic natural products, quadrone (1), suberosenone (2), suberosanone (3), and suberosenol A acetate (4), are used to assign their ACs. TDDFT calculations of the ECD of 1 are used to assign its AC. The VCD spectrum of 1 is reported and also used, together with DFT calculations, to assign its AC. The ACs of 1 derived from its [alpha](D), ECD, and VCD are identical and in agreement with the AC previously determined via total synthesis. The previously undetermined ACs of 2-4, derived from their [alpha](D) values, have absolute configurations of their tricyclic cores identical to that of 1. Further studies of the ACs of these molecules using ECD and, especially, VCD are recommended to establish more definitively this finding. Our studies of the OR, ECD, and VCD of quadrone are the first to utilize DFT calculations of all three properties for the determination of the AC of a chiral natural product molecule.

  13. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  14. Stochastic singular optics

    CSIR Research Space (South Africa)

    Roux, FS

    2013-09-01

    Full Text Available Roux Presented at the International Conference on Correlation Optics 2013 Chernivtsi, Ukraine 18-20 September 2013 CSIR National Laser Centre, Pretoria, South Africa – p. 1/24 Contents ⊲ Defining Stochastic Singular Optics (SSO) ⊲ Tools of Stochastic... of vortices: topological charge ±1 (higher order are unstable). Positive and negative vortex densities np(x, y, z) and nn(x, y, z) ⊲ Vortex density: V = np + nn ⊲ Topological charge density: T = np − nn – p. 4/24 Subfields of SSO ⊲ Homogeneous, normally...

  15. Ultra-High Density Optical Recording

    National Research Council Canada - National Science Library

    Kryder, Mark

    1999-01-01

    .... The work was directed at developing an understanding of the cyclability of phase change media, the fabrication of solid immersion lens, the development of improved integrated engineering test beds...

  16. Density dependent effective interactions

    International Nuclear Information System (INIS)

    Dortmans, P.J.; Amos, K.

    1994-01-01

    An effective nucleon-nucleon interaction is defined by an optimal fit to select on-and half-off-of-the-energy shell t-and g-matrices determined by solutions of the Lippmann-Schwinger and Brueckner-Bethe-Goldstone equations with the Paris nucleon-nucleon interaction as input. As such, it is seen to better reproduce the interaction on which it is based than other commonly used density dependent effective interactions. The new (medium modified) effective interaction when folded with appropriate density matrices, has been used to define proton- 12 C and proton- 16 O optical potentials. With them elastic scattering data are well fit and the medium effects identifiable. 23 refs., 8 figs

  17. Aspirin reduces serum anti-melanocyte antibodies and soluble interleukin-2 receptors in vitiligo patients

    International Nuclear Information System (INIS)

    Zailaie, Mohamad Z.

    2005-01-01

    Increased serum levels of certain immunologic markers including immunoglobulin G (IgG) anti-melanocyte/ vitiligo antibodies (V-IgG) and soluble interleukin-2 receptors (sIL-2R) are associated with augmented humoral and cellular immunity involved in melanocyte cytotoxicity during the active phase of non-segmental vitiligo. Recent reports have shown that, aspirin possesses a wide range of immunomodulatory and antioxidant properties. Therefore, the aim of the present study is to investigate the effect of long-term treatment of vitiligo patients with low-dose oral aspirin on serum V-IgG activity and sIL-2R concentration. The present study was carried out at the Vitiligo Unit, King Abdul-Aziz University Medical Center, Jeddah, Kingdom of Saudi Arabia between March and October 2003. Eighteen female and 14 male patients with a recent onset of non-segmental vitiligo were divided into 2 equal groups. One group received a daily single dose of oral aspirin (300 mg) and the second group received only placebo for a period of 12 weeks. Serum V-IgG activity and sIL-2R concentration were determined before and at the end of treatment period. The V-IgG activity was measured using cellular enzyme-linked immunosorbent assay (ELISA) following incubation of IgG antibodies with an adult cultured melanocytes. Serum sIL-2R concentration was measured using the highly sensitive quantitative sandwich ELISA utilizing a commercially available kit. As expected, the serum V-IgG activity and sIL-2R concentration of the active vitiligo patients (0.81 +/- 0.23 optical density (O.D.), 1428 +/- 510 pg/ml) were significantly increased compared with that of controls (0.27 +/- 0.1 O.D., 846 +/- 312 pg/ml; p<0.05, p<0.01). Aspirin-treated vitiligo patients showed significant decrease in serum V-IgG activity and sIL-2R concentration (0.32 +/- 0.08 O.D., 756 +/- 216 pg/ml) compared with that of placebo-treated patients (0.83 +/- 0.19 O.D., 1327 +/- 392 pg/ml; p<0.01). Low-dose oral aspirin treatment of

  18. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  19. Effect of Ramadan fasting on serum heat shock protein 70 and serum lipid profile.

    Science.gov (United States)

    Zare, A; Hajhashemi, M; Hassan, Z M; Zarrin, S; Pourpak, Z; Moin, M; Salarilak, S; Masudi, S; Shahabi, S

    2011-07-01

    Ramadan, the holy month for the Islamic world, is a period every year when food and fluid intake is restricted to the pre-sunrise and post-sunset hours. The aim of this study was to evaluate the effect of Ramadan fasting on the serum concentration of heat shock protein 70 (HSP70) and serum lipid profile in healthy men. A total of 32 male volunteers with a mean age of 28.5 (range 23-37) years were selected for the study. Blood samples were obtained one day prior to Ramadan and on the 3rd and 25th days of fasting. Serum HSP70, triglyceride (TG), cholesterol (Chol), low-density lipoprotein (LDL) and high-density lipoprotein (HDL), LDL/HDL and Chol/HDL ratios were investigated. It was observed that the mean concentrations of serum HSP70 and HDL on the 25th day of Ramadan were significantly higher than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels on the 3rd day of Ramadan was significantly higher than those recorded one day before Ramadan. Mean concentrations of serum TG, Chol, LDL, and LDL/HDL and Chol/HDL ratios on the 25th day of Ramadan were significantly lower than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels found on the 3rd day of Ramadan were also significantly lower than those recorded one day before Ramadan. Ramadan fasting increases serum HSP70 and improves serum lipid profile.

  20. Nutritional manipulation of primate retinas, I: effects of lutein or zeaxanthin supplements on serum and macular pigment in xanthophyll-free rhesus monkeys.

    Science.gov (United States)

    Neuringer, Martha; Sandstrom, Marita M; Johnson, Elizabeth J; Snodderly, D Max

    2004-09-01

    The xanthophylls lutein (L) and zeaxanthin (Z) are the primary components of macular pigment (MP) and may protect the macula from age-related degeneration (AMD). In this study, L or Z was fed to rhesus monkeys reared on xanthophyll-free diets to follow the accumulation of serum carotenoids and MP over time. Eighteen rhesus monkeys were fed xanthophyll-free semipurified diets from birth until 7 to 16 years. The diets of six were then supplemented with pure L and six with pure Z at 3.9 micromol/kg per day (2.2 mg/kg per day) for 24 to 56 weeks. At baseline and 4- to 12-week intervals during supplementation, serum carotenoids were measured by HPLC, and MP density was estimated by two-wavelength reflectometry. Serum carotenoids and MP were also measured in monkeys fed a stock diet. Monkeys fed xanthophyll-free diets had no L or Z in serum and no detectable MP. During supplementation, serum L or Z increased rapidly over the first 4 weeks and from 16 weeks onward maintained similar levels, both several times higher than in stock-diet-fed monkeys. The central peak of MP optical density increased to a relatively steady level by 24 to 32 weeks in both L- and Z-fed groups. Rhesus monkeys fed a stock diet had lower blood concentrations of L than those found in humans and other nonhuman primates. Rhesus monkeys respond to either dietary L or Z supplementation with increases in serum xanthophylls and MP, even after life-long xanthophyll deficiency. These animals provide a potential model to study mechanisms of protection from AMD. Copyright Association for Research in Vision and Ophthalmology

  1. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  2. Níveis s��ricos de vitamina B12 não se relacionam com baixa densidade mineral óssea em mulheres brasileiras na pós-menopausa Serum levels of vitamin B12 are not related to low bone mineral density in postmenopausal Brazilian women

    Directory of Open Access Journals (Sweden)

    Adriana Maria Kakehasi

    2012-12-01

    time. It has been described an association between low serum vitamin B12, osteoporosis and increased risk of bone fractures, but the studies are heterogeneous and the results are controversial. OBJECTIVE: To investigate the association between plasma levels of vitamin B12 and bone mineral density in a group of asymptomatic women after menopause. METHODS: Asymptomatic postmenopausal women were consecutively invited to participate in this cross-sectional study. Bone mineral density (lumbar spine and femur was measured by DXA Lunar Prodigy Vision, and blood levels of vitamin B12, calcium, phosphorus, bone alkaline phosphatase (BAF, and parathyroid hormone were determined. For the diagnostic of osteoporosis the World Health Organization criteria were considered. RESULTS: Seventy women were included, mean age 62.5 ± 7 years. Eighteen (25.7% women had normal bone mineral density, 33 (47.1% had osteopenia and 19 (27.1% had osteoporosis. Six (8.6% patients had wrist fracture; two (2.8% reported a diagnosis of vertebral fracture and only one (1.4% patient had suffered a hip fracture. The levels of vitamin B12 (mean ± SD, pg/mL of women with normal bone mineral density, osteopenia and osteoporosis were 590.2 ± 364.3, 536.6 ± 452.3, and 590.2 ± 497.9, respectively (P = 0.881. Multiple regression analysis showed that body mass index and BAF were the main predictors of lumbar spine bone mineral density. CONCLUSION: The results indicate that vitamin B12 serum levels are not related to bone mineral density in this group of Brazilian postmenopausal women.

  3. Serum apolipoprotein E concentration and polymorphism influence serum lipid levels in Chinese Shandong Han population.

    Science.gov (United States)

    Han, ShuYi; Xu, YiHui; Gao, MeiHua; Wang, YunShan; Wang, Jun; Liu, YanYan; Wang, Min; Zhang, XiaoQian

    2016-12-01

    Apolipoprotein E (ApoE), which has been shown to influence serum lipid parameters, can bind to multiple types of lipids and plays an important role in the metabolism and homeostasis of lipids and lipoproteins. A previous study showed that ApoE concentration significantly affects serum lipid levels independently of ApoE polymorphism. The serum lipid levels were also closely correlated with dietary habits, and Shandong cuisine is famous for its high salt and oil contents, which widely differ among the different areas in China. Therefore, studying the effect of ApoE polymorphism on ApoE concentration and serum lipid levels in Shandong province is very important.A total of 815 subjects including 285 men and 530 women were randomly selected and studied from Jinan, Shandong province. In order to evaluate the association of ApoE polymorphism and serum level on lipid profiles, the ApoE genotypes, as well as levels of fasting serum ApoE and other lipid parameters, were detected in all subjects.The frequency of the ApoE E3 allele was highest (83.1%), while those of E2 and E4 were 9.4% and 7.5%, respectively, which are similar to those in other Asian populations. ApoE2 allele carriers showed significantly increased ApoE levels but lower levels of serum total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), and Apolipoprotein B (ApoB).We found that ApoE level is influenced by ApoE polymorphism in a gene-dependent manner. The ApoE polymorphism showed different influences on serum lipid parameters with increasing age and body mass index (BMI) in our Shandong Han population.

  4. Serum YKL-40

    DEFF Research Database (Denmark)

    Mylin, Anne K; Abildgaard, Niels; Johansen, Julia S

    2015-01-01

    to clinical progression, i.e. skeletal-related events (SREs), in 230 newly diagnosed patients with multiple myeloma receiving intravenous bisphosphonates. Serum concentrations of YKL-40 and biochemical bone markers (CTX-MMP, CTX-I, PINP) were measured at diagnosis. Patients were evaluated every third month...

  5. 79 - 81_Wali - Serum

    African Journals Online (AJOL)

    DR. AMINU

    2013-06-01

    Jun 1, 2013 ... SERUM ANTIOXIDANT VITAMINS LEVELS IN CHILDREN WITH SICKLE. CELL ANAEMIA IN ... play a role in the development of sickle cell anaemic complications. In the current study, ... vaso-occlusive episodes, acute chest syndrome and impaired ... frequency of sickling crises accompanied by tissue or.

  6. Optic densitometry in radiographic images to evaluate nutritional secondary hyperparathyroidism in kittens

    International Nuclear Information System (INIS)

    Rahal, S.C.; Mortari, A.C.; Caporali, E.H.G.; Vulcano, L.C.; Santos, F.A.M. dos; Takahira, R.K.; Crocci, A.J.

    2002-01-01

    The aim of this study was to evaluate the modification of bone mineral density, as well as the serum biochemistry variation in the nutritional secondary hyperparathyroidism. Ten crossbreed cats, initial aging between 2 and 3 months, and weighing 820 grams were used. After 10 days of adaptation, they were fed with raw beef heart for 60 days. At the end of adaptation time and every 15 days, exams were realized. The method of optical densitometry in radiographic images of the right radius and ulna was used. There was no statistical difference in the bone mineral densitometry between the end of adaptation period and with 15 days of consuming a diet of beef heart. At 30 days the bone density decreased statistically, and it was in the same level at 45 and 60 days. There was no statistical difference in the serum calcium and phosphorus concentrations in all observation time. Serum alkaline phosphatase concentration varied and it was increased above normal variation in the 45 th and 60 th day of the diet. It was possible to conclude that bone densitometry in radiographic images is an efficient method to evaluate bone demineralization, and calcium, phosphorus and alkaline phosphatase serum biochemistry analysis are limited value [pt

  7. Non-linear optical materials

    CERN Document Server

    Saravanan, R

    2018-01-01

    Non-linear optical materials have widespread and promising applications, but the efforts to understand the local structure, electron density distribution and bonding is still lacking. The present work explores the structural details, the electron density distribution and the local bond length distribution of some non-linear optical materials. It also gives estimation of the optical band gap, the particle size, crystallite size, and the elemental composition from UV-Visible analysis, SEM, XRD and EDS of some non-linear optical materials respectively.

  8. Bone density in apheresis donors and whole blood donors

    NARCIS (Netherlands)

    Boot, C.L.; Luken, J.S.; van den Burg, P.J.M.; de Kort, W.L.A.M.; Koopman, M.M.W.; Vrielink, H.; van Schoor, N.M.; den Heijer, M.; Lips, P.

    2015-01-01

    Apheresis donation using citrate causes acute decrease in serum calcium and increase in serum parathyroid hormone. Long-term consequences, such as decrease in bone mineral density (BMD), are not known. In this study, we compared the BMD of 20 postmenopausal apheresis donors (mean donation number 115

  9. Nanocomposite materials based on poly(vinyl chloride) and bovine serum albumin modified ZnO through ultrasonic irradiation as a green technique: Optical, thermal, mechanical and morphological properties.

    Science.gov (United States)

    Mallakpour, Shadpour; Darvishzadeh, Marzieh

    2018-03-01

    In this project, physicochemical properties of poly(vinyl chloride) (PVC) reinforced by ZnO nanoparticles (NPs) were studied. Firstly, ZnO NPs were modified with bovine serum albumin (BSA) as an organo-modifier and biocompatible substance through ultrasound irradiation as environmental friendly, low cost and rapid means. Nanocomposite (NC) films were prepared by loadings of various ratios of ZnO/BSA NPs (3, 6 and 9wt%) inside the PVC. Structural morphology and physical properties of the ZnO-BSA NPs and NC films were investigated via Fourier transform infrared spectroscopy, X-ray diffraction, thermogravimetric analysis (TGA), transmission electron microscopy and field emission scanning electron microscopy. According to the obtained information from the TGA, an increase in the thermal stability can be clearly observed. Also the results of contact angle analysis indicated with increasing percent of ZnO/BSA NPs into PVC the hydrophilic behaviors of NCs were increased. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Serum Creatinine: Not So Simple!

    OpenAIRE

    DELANAYE, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDM...

  11. The Human Serum Metabolome

    Science.gov (United States)

    Psychogios, Nikolaos; Hau, David D.; Peng, Jun; Guo, An Chi; Mandal, Rupasri; Bouatra, Souhaila; Sinelnikov, Igor; Krishnamurthy, Ramanarayan; Eisner, Roman; Gautam, Bijaya; Young, Nelson; Xia, Jianguo; Knox, Craig; Dong, Edison; Huang, Paul; Hollander, Zsuzsanna; Pedersen, Theresa L.; Smith, Steven R.; Bamforth, Fiona; Greiner, Russ; McManus, Bruce; Newman, John W.; Goodfriend, Theodore; Wishart, David S.

    2011-01-01

    Continuing improvements in analytical technology along with an increased interest in performing comprehensive, quantitative metabolic profiling, is leading to increased interest pressures within the metabolomics community to develop centralized metabolite reference resources for certain clinically important biofluids, such as cerebrospinal fluid, urine and blood. As part of an ongoing effort to systematically characterize the human metabolome through the Human Metabolome Project, we have undertaken the task of characterizing the human serum metabolome. In doing so, we have combined targeted and non-targeted NMR, GC-MS and LC-MS methods with computer-aided literature mining to identify and quantify a comprehensive, if not absolutely complete, set of metabolites commonly detected and quantified (with today's technology) in the human serum metabolome. Our use of multiple metabolomics platforms and technologies allowed us to substantially enhance the level of metabolome coverage while critically assessing the relative strengths and weaknesses of these platforms or technologies. Tables containing the complete set of 4229 confirmed and highly probable human serum compounds, their concentrations, related literature references and links to their known disease associations are freely available at http://www.serummetabolome.ca. PMID:21359215

  12. Selected Blood Serum Elements in Van (Turkey Cats

    Directory of Open Access Journals (Sweden)

    V. Altunok

    2007-01-01

    Full Text Available The Turkish Van cat originates from eastern Turkey. One of the characteristic features of Van cats is the colour of their eyes, which can be both eyes blue, both eyes amber or one eye blue and the other amber. Serum essential trace, macro and industrial element concentrations of Van cats (n = 47 according to sex, age, hair length and eye colour differences were investigated. Serum aluminium, arsenic, boron, barium, cobalt, chromium, copper, gallium, indium, iron, lead, lithium, manganese, nickel, selenium, silver, sulphur, strontium, vanadium and zinc were measured with ICP-OES plasma optical atomic emission spectrometer. In result, serum aluminium, barium, copper, manganese and strontium levels in male cats were found higher (p p p p > 0.05 found in the age and hair length groups. Our results indicate that several of the blood serum elements of Van cats may be related to their eye colours and sex differences.

  13. Are galaxy discs optically thick?

    International Nuclear Information System (INIS)

    Disney, Michael; Davies, Jonathan; Phillipps, Steven

    1989-01-01

    We re-examine the classical optical evidence for the low optical depths traditionally assigned to spiral discs and argue that it is highly model-dependent and unconvincing. In particular, layered models with a physically thin but optically thick dust layer behave like optically thin discs. The opposite hypotheses, that such discs are optically thick is then examined in the light of modern evidence. We find it to be consistent with the near-infrared and IRAS observations, with the surface brightnesses, with the HI and CO column densities and with the Hα measurements. (author)

  14. Leptin and bone mineral density

    DEFF Research Database (Denmark)

    Morberg, Cathrine M.; Tetens, Inge; Black, Eva

    2003-01-01

    Leptin has been suggested to decrease bone mineral density (BMD). This observational analysis explored the relationship between serum leptin and BMD in 327 nonobese men (controls) (body mass index 26.1 +/- 3.7 kg/m(2), age 49.9 +/- 6.0 yr) and 285 juvenile obese men (body mass index 35.9 +/- 5.9 kg...... males, but it also stresses the fact that the strong covariation between the examined variables is a shortcoming of the cross-sectional design....

  15. Density operators in quantum mechanics

    International Nuclear Information System (INIS)

    Burzynski, A.

    1979-01-01

    A brief discussion and resume of density operator formalism in the way it occurs in modern physics (in quantum optics, quantum statistical physics, quantum theory of radiation) is presented. Particularly we emphasize the projection operator method, application of spectral theorems and superoperators formalism in operator Hilbert spaces (Hilbert-Schmidt type). The paper includes an appendix on direct sums and direct products of spaces and operators, and problems of reducibility for operator class by using the projection operators. (author)

  16. Free serum thyroxine

    International Nuclear Information System (INIS)

    Degrossi, O.J.; Altschuler, Noe; Cabrejas, M.L. de; Pinkas, Mirta; Garcia del Rio, Hernan

    1982-01-01

    The use of radiommunoassay (RIA) tehcniques has increased the diagnosis of thyroid functional alterations. A solid phase RIA method for free thyroxine (FT4) measurement was tested. Serum FT4, Total T4, T3 and TSH were determined by radioimmunoassay in 179 subjects. One hundred twenty two patients were normal (8 to 75 years old); FT4 was 1.42 +- 0.03 ng/100 ml (avg. value and std. error). In 27 cases of thyrotoxicosis the values were 4.66 +- 0.48 ng/100 ml and in 15 cases of hypothyroidism 0.50 +- 0.06 ng/100 ml (statistics probability [es

  17. Nonlinear optics

    International Nuclear Information System (INIS)

    Boyd, R.W.

    1992-01-01

    Nonlinear optics is the study of the interaction of intense laser light with matter. This book is a textbook on nonlinear optics at the level of a beginning graduate student. The intent of the book is to provide an introduction to the field of nonlinear optics that stresses fundamental concepts and that enables the student to go on to perform independent research in this field. This book covers the areas of nonlinear optics, quantum optics, quantum electronics, laser physics, electrooptics, and modern optics

  18. Physical optics

    International Nuclear Information System (INIS)

    Kim Il Gon; Lee, Seong Su; Jang, Gi Wan

    2012-07-01

    This book indicates physical optics with properties and transmission of light, mathematical expression of wave like harmonic wave and cylindrical wave, electromagnetic theory and light, transmission of light with Fermat principle and Fresnel equation, geometrical optics I, geometrical optics II, optical instrument such as stops, glasses and camera, polarized light like double refraction by polarized light, interference, interference by multiple reflections, diffraction, solid optics, crystal optics such as Faraday rotation and Kerr effect and measurement of light. Each chapter has an exercise.

  19. Physical optics

    Energy Technology Data Exchange (ETDEWEB)

    Kim Il Gon; Lee, Seong Su; Jang, Gi Wan

    2012-07-15

    This book indicates physical optics with properties and transmission of light, mathematical expression of wave like harmonic wave and cylindrical wave, electromagnetic theory and light, transmission of light with Fermat principle and Fresnel equation, geometrical optics I, geometrical optics II, optical instrument such as stops, glasses and camera, polarized light like double refraction by polarized light, interference, interference by multiple reflections, diffraction, solid optics, crystal optics such as Faraday rotation and Kerr effect and measurement of light. Each chapter has an exercise.

  20. Serum myostatin is reduced in individuals with metabolic syndrome.

    Directory of Open Access Journals (Sweden)

    Der-Sheng Han

    Full Text Available Myostatin is a negative regulator of skeletal muscle mass and may also modulate energy metabolism secondarily. We aim to investigate the relationship between serum myostatin and the metabolic variables in diabetic (DM and non-diabetic subjects.A cross-sectional study recruiting 246 consecutive DM patients and 82 age- and gender-matched non-diabetic individuals at a medical center was conducted. The variables of anthropometry and blood chemistry were obtained. Serum myostatin level was measured with enzyme immunoassay.DM group had lower serum myostatin compared with non-diabetics (7.82 versus 9.28 ng/ml, p<0.01. Sixty-two percent of the recruited individuals had metabolic syndrome (MetS. The patients with MetS had significantly lower serum myostatin than those without (7.39 versus 9.49 ng/ml, p<0.001. The serum myostatin level decreased with increasing numbers of the MetS components (p for trend<0.001. The patients with higher body mass index, larger abdominal girth, lower high-density lipoprotein cholesterol (HDL-C, and higher triglycerides had lower serum myostatin than those without. The serum myostatin level was independently negatively related to larger abdominal girth, higher triglycerides, and lower HDL-C after adjustment. The odds ratios for MetS, central obesity, low HDL-C, high triglycerides, and DM were 0.85, 0.88, 0.89, 0.85, and 0.92, respectively, when serum myostatin increased per 1 ng/mL, in the binary logistic regression models.Lower serum myostatin independently associated with MetS, central obesity, low HDL-C, and high triglycerides after adjustment. Higher serum myostatin is associated with favorable metabolic profiles.

  1. Serum creatine kinase isoenzymes in children with osteogenesis imperfecta.

    Science.gov (United States)

    D'Eufemia, P; Finocchiaro, R; Zambrano, A; Lodato, V; Celli, L; Finocchiaro, S; Persiani, P; Turchetti, A; Celli, M

    2017-01-01

    This study evaluates serum creatine kinase isoenzyme activity in children with osteogenesis imperfecta to determine its usefulness as a biochemical marker during treatment with bisphosphonate. The changes of creatine kinase (CK) isoenzyme activity during and after discontinuation therapy were observed. These results could be useful in addressing over-treatment risk prevention. The brain isoenzyme of creatine kinase (CKbb) is highly expressed in mature osteoclasts during osteoclastogenesis, thus plays an important role in bone resorption. We previously identified high serum CKbb levels in 18 children with osteogenesis imperfect (OI) type 1 treated for 1 year with bisphosphonate (neridronate). In the present study, serum CK isoenzymes were evaluated in the same children with continuous versus discontinued neridronate treatment over a further 2-year follow-up period. This study included 18 children with OI type 1, 12 with continued (group A) and 6 with ceased (group B) neridronate treatment. Auxological data, serum biochemical markers of bone metabolism, bone mineral density z-score, and serum total CK and isoenzyme activities were determined in both groups. Serum CKbb was progressively and significantly increased in group A (p < 0.004) but rapidly decreased to undetectable levels in group B. In both groups, the cardiac muscle creatine kinase isoenzyme (CKmb) showed a marked decrease, while serum C-terminal telopeptide (CTx) levels were almost unchanged. This study provides evidence of the cumulative effect of neridronate administration in increasing serum CKbb levels and the reversible effect after its discontinuation. This approach could be employed for verifying the usefulness of serum CKbb as a biochemical marker in patients receiving prolonged bisphosphonate treatment. Moreover, the decreased serum CKmb levels suggest a systemic effect of these drugs.

  2. Concentration-dependent sedimentation properties of ferritin: implications for estimation of iron contents of serum ferritins

    International Nuclear Information System (INIS)

    Niitsu, Y.; Adachi, C.; Takahashi, F.; Goto, Y.; Kohgo, Y.; Urushizaki, I.; Listowsky, I.

    1985-01-01

    Serum ferritins from various sources sedimented at lower densities than tissue ferritins in sucrose gradient centrifugation systems. The sedimentation patterns of ferritins, however, were shown to be dependent on the concentration of the protein; as the concentration decreased the protein appeared to sediment at lower densities. Thus, at the low concentration levels usually used for analysis of serum ferritin, tissue ferritins also sedimented in the same lower density regions. Iron labeling experiments indicated that the sedimentation changes upon dilution were not due to release of iron or was there any indication that the protein dissociated into subunits. The anomalous sedimentation behavior of serum ferritin should therefore not be interpreted in terms of its iron content. The disclosure that serum ferritins may have full complements of iron is counter to the prevalent view that serum ferritins are low iron forms and has potential implications with regard to the sources and possible function of this protein in the circulation

  3. Quantum optics

    National Research Council Canada - National Science Library

    Agarwal, G. S

    2013-01-01

    .... Focusing on applications of quantum optics, the textbook covers recent developments such as engineering of quantum states, quantum optics on a chip, nano-mechanical mirrors, quantum entanglement...

  4. Diet, Alcohol Consumption and Serum Lipid Levels of Elderly Men ...

    African Journals Online (AJOL)

    Methodology: Elderly subjects attending quarterly medical lectures organized by a non-governmental organization at the Federal Medical Centre, Asaba were recruited. Information on diet, alcohol consumption and hypertension were obtained and serum lipids were determined using standard cholesterol / low density ...

  5. Assessment of Serum Levels of Magnesium and Manganese among ...

    African Journals Online (AJOL)

    Pregnant women in developing countries have been reported to consume diets with low density of minerals and essential trace elements. Therefore, this study aims to assess the serum levels of magnesium and manganese and its trimester correlates among pregnant women in Ika community of Delta state, Nigeria.

  6. marital status and occupation versus serum total cholesterol and hdl

    African Journals Online (AJOL)

    DR. AMIN

    ABSTRACT. The influence of marital status and occupation on serum total cholesterol (TC) and high density lipoprotein cholesterol (HDL – CH) concentrations was studied in sixty one (61) adult male and female Hausa subjects aged 20 – 50 years. Irrespective of marital status and occupation, female subjects had higher ...

  7. Electronic and optical properties of the LiCdX (X = N, P, As and Sb) filled-tetrahedral compounds with the Tran–Blaha modified Becke–Johnson density functional

    International Nuclear Information System (INIS)

    Bouhemadou, A.; Bin-Omran, S.; Allali, D.; Al-Otaibi, S.M.; Khenata, R.; Al-Douri, Y.; Chegaar, M.; Reshak, A.H.

    2015-01-01

    Highlights: • Electronic and optical properties of the LiCdX compounds have been predicted. • Tran–Blaha-modified Becke–Johnson functional significantly improves the band gap. • We predict a direct band gap in all of the considered LiCdX compounds. • Origin of the peaks in the optical spectra is determined. - Abstract: The structural, electronic and optical properties of the LiCdN, LiCdP, LiCdAs and LiCdSb filled-tetrahedral compounds have been explored from first-principles. The calculated structural parameters are consistent with the available experimental results. Since DFT with the common LDA and GGA underestimates the band gap, we use a new developed functional able to accurately describe the electronic structure of semiconductors, namely the Tran–Blaha-modified Becke–Johnson potential. The four investigated compounds demonstrate semiconducting behavior with direct band gap ranging from about 0.32 to 1.65 eV. The charge-carrier effective masses are evaluated at the topmost valence band and at the bottommost conduction band. The evolution of the value and nature of the energy band gap under pressure effect is also investigated. The frequency-dependent complex dielectric function and some macroscopic optical constants are estimated. The microscopic origins of the structures in the optical spectra are determined in terms of the calculated energy band structures

  8. Electronic and optical properties of the LiCdX (X = N, P, As and Sb) filled-tetrahedral compounds with the Tran–Blaha modified Becke–Johnson density functional

    Energy Technology Data Exchange (ETDEWEB)

    Bouhemadou, A., E-mail: a_bouhemadou@yahoo.fr [Laboratory for Developing New Materials and their Characterization, University of Setif 1, Setif 19000 (Algeria); Bin-Omran, S. [Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Department of Physics, Faculty of Science & Humanitarian Studies, Salman Bin Abdalaziz University, Alkharj 11942 (Saudi Arabia); Allali, D. [Laboratory for Developing New Materials and their Characterization, University of Setif 1, Setif 19000 (Algeria); Al-Otaibi, S.M. [Department of Physics and Astronomy, College of Science, King Saud University, P.O. Box 2455, Riyadh 11451 (Saudi Arabia); Khenata, R. [Laboratoire de Physique Quantique et de Modélisation Mathématique (LPQ3M), Département de Technologie, Université de Mascara, Mascara 29000 (Algeria); Al-Douri, Y. [Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar, Perlis 01000 (Malaysia); Chegaar, M. [Department of Physics, Faculty of Science, University of Setif 1, Setif 19000 (Algeria); Reshak, A.H. [New Technologies-Research Center, University of West Bohemia, Univerzitni 8, Pilson 306 14 (Czech Republic); Center of Excellence Geopolymer and Green Technology, School of Material Engineering, University Malaysia Perlis, Kangar, Perlis 01007 (Malaysia)

    2015-04-15

    Highlights: • Electronic and optical properties of the LiCdX compounds have been predicted. • Tran–Blaha-modified Becke–Johnson functional significantly improves the band gap. • We predict a direct band gap in all of the considered LiCdX compounds. • Origin of the peaks in the optical spectra is determined. - Abstract: The structural, electronic and optical properties of the LiCdN, LiCdP, LiCdAs and LiCdSb filled-tetrahedral compounds have been explored from first-principles. The calculated structural parameters are consistent with the available experimental results. Since DFT with the common LDA and GGA underestimates the band gap, we use a new developed functional able to accurately describe the electronic structure of semiconductors, namely the Tran–Blaha-modified Becke–Johnson potential. The four investigated compounds demonstrate semiconducting behavior with direct band gap ranging from about 0.32 to 1.65 eV. The charge-carrier effective masses are evaluated at the topmost valence band and at the bottommost conduction band. The evolution of the value and nature of the energy band gap under pressure effect is also investigated. The frequency-dependent complex dielectric function and some macroscopic optical constants are estimated. The microscopic origins of the structures in the optical spectra are determined in terms of the calculated energy band structures.

  9. Serum Creatinine: Not So Simple!

    Science.gov (United States)

    Delanaye, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). © 2017 S. Karger AG, Basel.

  10. Imaging Breast Density: Established and Emerging Modalities

    Directory of Open Access Journals (Sweden)

    Jeon-Hor Chen

    2015-12-01

    Full Text Available Mammographic density has been proven as an independent risk factor for breast cancer. Women with dense breast tissue visible on a mammogram have a much higher cancer risk than women with little density. A great research effort has been devoted to incorporate breast density into risk prediction models to better estimate each individual’s cancer risk. In recent years, the passage of breast density notification legislation in many states in USA requires that every mammography report should provide information regarding the patient’s breast density. Accurate definition and measurement of breast density are thus important, which may allow all the potential clinical applications of breast density to be implemented. Because the two-dimensional mammography-based measurement is subject to tissue overlapping and thus not able to provide volumetric information, there is an urgent need to develop reliable quantitative measurements of breast density. Various new imaging technologies are being developed. Among these new modalities, volumetric mammographic density methods and three-dimensional magnetic resonance imaging are the most well studied. Besides, emerging modalities, including different x-ray–based, optical imaging, and ultrasound-based methods, have also been investigated. All these modalities may either overcome some fundamental problems related to mammographic density or provide additional density and/or compositional information. The present review article aimed to summarize the current established and emerging imaging techniques for the measurement of breast density and the evidence of the clinical use of these density methods from the literature.

  11. Radioimmunoassay of cholylglycine in serum

    International Nuclear Information System (INIS)

    Wakushima, Tadashi; Yamanishi, Yasuhito; Hirayama, Chisato

    1979-01-01

    Serum levels of cholylglycines (CG) were determined by radioimmunoassay and that of total bile acids (TBA) by enzymatic method. In normal subjects, serum levels of CG, TBA and CG/TBA ratio were 0.6 +- 0.4 μM, 7 +- 2 μM, and 0.08 +- 0.06, respectively. They were increased markedly in acute hepatitis and moderately in chronic hepatitis and cirrhosis. Thus, measurement of serum CG as compared with serum TBA appears to be a sensitive liver test. (author)

  12. Optics equations for aero-optical analysis

    Science.gov (United States)

    Sutton, George W.; Pond, John E.

    2011-05-01

    Aero-optical effects occur around moving air vehicles and impact passive imaging or active systems. The air flow around the vehicle is compressed, and often there is a turbulent shear and/or boundary layer both of which cause variations in the index of refraction. Examples of these are reconnaissance aircraft, the Stratospheric Observatory for Infrared Optics (SOFIA), and optically homing hypersonic interceptors. In other applications, a laser beam can be formed within the vehicle, and projected outward and focused on an object. These include the Airborne Laser Laboratory, Airborne Laser and the Airborne Tactical Laser. There are many compressible fluid mechanics computer programs that can predict the air density distribution of the surrounding flow field including density fluctuations in turbulent shear and/or boundary layers. It is necessary for the physical optics to be used to predict the properties of the ensuing image plane intensity distribution, whether passive or active. These include the time-averaged image blur circle and instantaneous realizations. (Ray tracing is a poor approximation that gives erroneous results for small aberrations.)

  13. Electroabsorption optical modulator

    Energy Technology Data Exchange (ETDEWEB)

    Skogen, Erik J.

    2017-11-21

    An electroabsorption modulator incorporates waveguiding regions along the length of the modulator that include quantum wells where at least two of the regions have quantum wells with different bandgaps. In one embodiment of the invention, the regions are arranged such that the quantum wells have bandgaps with decreasing bandgap energy along the length of the modulator from the modulator's input to its output. The bandgap energy of the quantum wells may be decreased in discrete steps or continuously. Advantageously, such an arrangement better distributes the optical absorption as well as the carrier density along the length of the modulator. Further advantageously, the modulator may handle increased optical power as compared with prior art modulators of similar dimensions, which allows for improved link gain when the optical modulator is used in an analog optical communication link.

  14. X-ray and neutron small-angle scattering studies of human serum lipoproteins

    International Nuclear Information System (INIS)

    Luzzati, V.; Tardieu, A.; Mateu, L.; Sardet, C.; Stuhrmann, H.B.; Aggerbeck, L.; Scanu, A.M.

    1976-01-01

    The paper describes an extended x-ray study of two types of human serum lipoproteins and a neutron study of one of them. The results are similar and to some extent complementary. Serum lipoproteins provide an excellent illustration of the wealth of information that can be obtained by a small-angle scattering approach to the structure of particles with non-uniform density distribution, by using solvents of variable density

  15. Relationship between serum total magnesium and serum potassium ...

    African Journals Online (AJOL)

    Relationship between serum total magnesium and serum potassium in emergency surgical patients in a tertiary hospital in Ghana. Robert Djagbletey, Brenda Phillips, Frank Boni, Christian Owoo, Ebenezer Owusu-Darkwa, Papa Kobina Gyakye deGraft-Johnson, Alfred E. Yawson ...

  16. Serum lipids coupled with menopausal status may be used as biomarkers in female gallstone patients

    International Nuclear Information System (INIS)

    Awan, A.Y.; Channa, N.A.; Solangi, D.A.; Tabassum, N.

    2017-01-01

    Objective: Females with different menopausal status are compared for serum lipids to explore the role of menopausal status in developing gallstones. Methodology: This study was conducted at Institute of Biochemistry, University of Sindh Jamshoro, Pakistan. A total number of 135 female gallstone patients admitted at Liaquat University Hospital, Wali Bhai Rajputana Hospital, Hyderabad and other hospitals of Hyderabad, Pakistan and 170 age and gender matched control subjects were selected for the study. The serum samples of patients of different menopausal status and control group were analyzed for the lipid contents. Gallstones recovered from the patients were also analyzed for the composition by FTIR. Results: Serum total cholesterol (TC) and serum high density lipoprotein cholesterol (HDL-C) were significantly varied among all age groups while serum triglycerides (TG), serum very low density lipoprotein cholesterol (VLDL-C) and serum total lipids (TL) were found to be significantly differed among four different types of gallstone formers. Consumers of non-branded oil and non-branded ghee were found with significant lipid alterations in comparison to control group. Major lipid alterations were found in female gallstone patients with pre and peri-menopause. Conclusion: Raised serum TC, serum TG and decreased serum HDL-C in addition to pre- and peri-menopausal status may be considered as biomarkers for female gallstone patients.

  17. Optical Computing

    OpenAIRE

    Woods, Damien; Naughton, Thomas J.

    2008-01-01

    We consider optical computers that encode data using images and compute by transforming such images. We give an overview of a number of such optical computing architectures, including descriptions of the type of hardware commonly used in optical computing, as well as some of the computational efficiencies of optical devices. We go on to discuss optical computing from the point of view of computational complexity theory, with the aim of putting some old, and some very recent, re...

  18. Density-dependent electron scattering in photoexcited GaAs

    DEFF Research Database (Denmark)

    Mics, Zoltán; D'’Angio, Andrea; Jensen, Søren A.

    2013-01-01

    —In a series of systematic optical pump - terahertz probe experiments we study the density-dependent electron scattering rate in photoexcited GaAs in a large range of carrier densities. The electron scattering time decreases by as much as a factor of 4, from 320 to 60 fs, as the electron density...

  19. Bone mineral density and serum levels of 25 OH vitamin D in chronic users of antiepileptic drugs Densidade mineral óssea e níveis séricos de 25 OH vitamina D em usuários crônicos de drogas antiepilépticas

    Directory of Open Access Journals (Sweden)

    Carolina A.M. Kulak

    2004-12-01

    Full Text Available The aim of this cross sectional study was to evaluate bone mineral density (BMD and serum levels of 25-hydroxy vitamin D (25OHD in a group of patients taking antiepileptic drugs (AED for a seizure disorder. Between May-2001 and January-2003, we evaluated 58 patients (40 women/18 men, 34.4±6 years old living in Curitiba or in its metropolitan area, on antiepileptic therapy for 2 to 38 years (10 on monotherapy /48 on multiple drugs regime. The group was matched by age, gender, and bone mass index to 29 healthy subjects (20 women/ 9 men; 34.2±5.9 years old. Medical history and physical exam were performed on all subjects with particular information sought about fractures and risks factors for osteoporosis. Blood samples were collected for total serum calcium, albumin, phosphorus, creatinine, total alkaline phosphatase, and liver function tests. BMD of the lumbar spine, femur and forearm was determined by dual energy X-ray absorptiometry (DXA, Hologic QDR 1000. Between February and April-2003, other blood samples were collected to measure 25OHD, intact paratohormone (PTH and calcium. Unemployment and smoking history were more frequent among patients than among controls (pO objetivo deste estudo transversal foi avaliar a densidade mineral óssea (DMO e os níveis de 25hidroxi vitamina D (25OHD em um grupo de pacientes com epilepsia e usuários crônicos de drogas antiepilépticas (DAE. Entre maio-2001 e janeiro-2003 avaliamos 58 pacientes (40 mulheres/18 homens residentes em Curitiba ou região metropolitana da cidade, com média de idade 34,4±6 anos e tempo de tratamento entre 2 e 38 anos (10 em monoterapia/48 em politerapia. O grupo de pacientes foi emparelhado por idade, sexo e índice de massa corpórea com 29 indivíduos aparentemente sadios (20 mulheres/9 homens; 34,2±5,9 anos. Pacientes e controles foram submetidos a anamnese e exame clínico, com ênfase na história de fraturas e fatores de risco para osteoporose. Nas visitas foram

  20. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  1. The inflammation markers in serum of tumor-bearing rats after plasmonic photothermal therapy

    Science.gov (United States)

    Bucharskaya, Alla B.; Maslyakova, Galina N.; Terentyuk, Georgy S.; Afanasyeva, Galina A.; Navolokin, Nikita A.; Zakharova, Natalia B.; Khlebtsov, Boris N.; Khlebtsov, Nikolai G.; Bashkatov, Alexey N.; Genina, Elina A.; Tuchin, Valery V.

    2018-02-01

    We report on plasmonic photothermal therapy of rats with inoculated cholangiocarcinoma through the intratumoral injection of PEG-coated gold nanorods followed by CW laser light irradiation. The length and diameter of gold nanorods were 41+/-8 nm and 10+/-2 nm, respectively; the particle mass-volume concentration was 400 μg/mL, which corresponds to the optical density of 20 at the wavelength 808 nm. The tumor-bearing rats were randomly divided into three groups: (1) without any treatment (control); (2) with only laser irradiation of tumor; (3) with intratumoral administration of gold nanorods and laser irradiation of tumors. An hour before laser irradiation, the animals were injected intratumorally with gold nanorod solutions in the amount of 30% of the tumor volume. The infrared 808-nm laser with power density of 2.3 W/cm2 was used for plasmonic photothermal therapy (PTT). The withdraw of animals from the experiment was performed 24 h after laser exposure. The content of lipid peroxidation products and molecular markers of inflammation (TNF-α, IGF-1, VEGF-C) was determined by ELISA test in serum of rats. The standard histological techniques with hematoxylin and eosin staining were used for morphological examination of tumor tissues. It was revealed that the significant necrotic changes were noted in tumor tissue after plasmonic photothermal therapy, which were accompanied by formation of inflammatory reaction with release of proinflammatory cytokines and lipid peroxidation products into the bloodstream

  2. DETERMINATION OF SERUM ALBUMIN WITH ...

    African Journals Online (AJOL)

    The reaction of tribromoarsenazo(TB-ASA) with serum albumin in the presence of emulgent OP was studied by spectrophotometry. In a Britton-Robinson buffer solution at pH 2.9, tribromoarsenazo and bovine serum albumin can immediately form a red compound in the presence of emulgent OP with a maximum absorption ...

  3. Engineering Optics

    CERN Document Server

    Iizuka, Keigo

    2008-01-01

    Engineering Optics is a book for students who want to apply their knowledge of optics to engineering problems, as well as for engineering students who want to acquire the basic principles of optics. It covers such important topics as optical signal processing, holography, tomography, holographic radars, fiber optical communication, electro- and acousto-optic devices, and integrated optics (including optical bistability). As a basis for understanding these topics, the first few chapters give easy-to-follow explanations of diffraction theory, Fourier transforms, and geometrical optics. Practical examples, such as the video disk, the Fresnel zone plate, and many more, appear throughout the text, together with numerous solved exercises. There is an entirely new section in this updated edition on 3-D imaging.

  4. Treatment of Refractory Filamentary Keratitis With Autologous Serum Tears.

    Science.gov (United States)

    Read, Sarah P; Rodriguez, Marianeli; Dubovy, Sander; Karp, Carol L; Galor, Anat

    2017-09-01

    To report a case of filamentary keratitis (FK) successfully treated with autologous serum tears and to review the pathogenesis and management of FK. Case report including high-resolution anterior segment optical coherence tomography and filament histopathology. A 61-year-old Hispanic man presented with pain and photophobia of the right eye. He was found to have a corneal epithelial defect and a small peripheral infiltrate 4 months after Laser Assisted in situ Keratomileusis. After resolution of the epithelial defect, he developed FK. Over a 4-month period, conservative management with aggressive lubrication, lid hygiene, topical corticosteroids, topical cyclosporine, bandage contact lenses, and oral doxycycline failed to resolve the corneal filaments. Notably, treatment with 20% autologous serum tears, four times daily, led to a sustained resolution of the FK within 1 week. This case demonstrates the complexity of FK management and introduces autologous serum tears as a viable management option when conservative approaches to this condition fail.

  5. Synthesis and Biochemical effects of magnetite nanoparticle by surfactant-free electrochemical method in an aqueous system:the current density effect

    Directory of Open Access Journals (Sweden)

    Mousa Aliahmad

    2016-07-01

    Full Text Available Obejective(s: In this research, magnetite nanoparticles with an average size of 23-36 nm were successfully synthesized via surfactant-free electrochemical method using iron as the anode and water as the electrolyte in a closed aqueous system in the presence of NaOH at room temperature. Methods: The effect of the current density on product formation and particle size was investigated. Particle size was controlled by adjusting the current density. It was found that particle size decreases by decreasing the current density. In addition, the effect of current density  on the structural and optical properties of nanostructures were studied by X-ray diffraction, Field emission scanning electron microscopy, Fourier transformed infrared, and vibrating sample magnetometer techniques.  Results: The results obtained from the magnetization property study of samples at room temperature showed coactivity and saturation manetization of 0-100 Oe and 27.2- 40.5 emu. g-1, respectively. Finally, the results of biological activity study of nanoparticles on liver and kidney function in male wistar rats demonstrated that oral administration of NPs caused significant alterations to the levels of aspartate transaminase, alanine transaminase, and alkaline phosphatase in serum. Conclusions: No significant changes were detected in the groups treated with 10 and 100 ppm/ day nanostructure (P>0.05. There was a significant increase in the serum level of creatinine and blood urea nitrogen level (p

  6. Electron optics

    CERN Document Server

    Grivet, Pierre; Bertein, F; Castaing, R; Gauzit, M; Septier, Albert L

    1972-01-01

    Electron Optics, Second English Edition, Part I: Optics is a 10-chapter book that begins by elucidating the fundamental features and basic techniques of electron optics, as well as the distribution of potential and field in electrostatic lenses. This book then explains the field distribution in magnetic lenses; the optical properties of electrostatic and magnetic lenses; and the similarities and differences between glass optics and electron optics. Subsequent chapters focus on lens defects; some electrostatic lenses and triode guns; and magnetic lens models. The strong focusing lenses and pris

  7. FOREWORD: Special issue on density

    Science.gov (United States)

    Fujii, Kenichi

    2004-04-01

    This special issue on density was undertaken to provide readers with an overview of the present state of the density standards for solids, liquids and gases, as well as the technologies developed for measuring density. This issue also includes topics on the refractive index of gases and on techniques used for calibrating hydrometers so that almost all areas concerned with density standards are covered in four review articles and seven original articles, most of which describe current research being conducted at national metrology institutes (NMIs). A review article was invited from the Ruhr-Universität Bochum to highlight research on the magnetic suspension densimeters. In metrology, the determinations of the volume of a weight and the density of air are of primary importance in establishing a mass standard because the effect of the buoyancy force of air acting on the weight must be known accurately to determine the mass of the weight. A density standard has therefore been developed at many NMIs with a close relation to the mass standard. Hydrostatic weighing is widely used to measure the volume of a solid. The most conventional hydrostatic weighing method uses water as a primary density standard for measuring the volume of a solid. A brief history of the determination of the density of water is therefore given in a review article, as well as a recommended value for the density of water with a specified isotopic abundance. The most modern technique for hydrostatic weighing uses a solid density standard instead of water. For this purpose, optical interferometers for measuring the diameters of silicon spheres have been developed to convert the length standard into the volume standard with a small uncertainty. A review article is therefore dedicated to describing the state-of-the-art optical interferometers developed for silicon spheres. Relative combined standard uncertainties of several parts in 108 have been achieved today for measuring the volume and density of

  8. Statistical behaviour of optical vortex fields

    CSIR Research Space (South Africa)

    Roux, FS

    2009-09-01

    Full Text Available ) Density limitation→ effective profile for point vortex (remove evanescent field) . – p.10/37 Scintillated optical beams Optical beam in a turbulent atmosphere: → index variations cause random phase modulations → leads to distortion of the optical beam.... Weak scintillation→ continuous phase distortions that can be corrected by an adaptive optical system: Wavefront sensor Beam splitter Scintillated beam Corrected beam Deformable mirror Control signal . – p.11/37 Strong scintillation Strong scintillation...

  9. Grazing Incidence Neutron Optics

    Science.gov (United States)

    Gubarev, Mikhail V. (Inventor); Ramsey, Brian D. (Inventor); Engelhaupt, Darell E. (Inventor)

    2013-01-01

    Neutron optics based on the two-reflection geometries are capable of controlling beams of long wavelength neutrons with low angular divergence. The preferred mirror fabrication technique is a replication process with electroform nickel replication process being preferable. In the preliminary demonstration test an electroform nickel optics gave the neutron current density gain at the focal spot of the mirror at least 8 for neutron wavelengths in the range from 6 to 20.ANG.. The replication techniques can be also be used to fabricate neutron beam controlling guides.

  10. Neuromyelitis optica in a young child with positive serum autoantibody

    OpenAIRE

    Loma, Ingrid P.; Asato, Miya R.; Filipink, Robyn A.; Alper, Gulay

    2008-01-01

    Relapsing neuromyelitis optica is rare in children. The identification of highly specific serum autoantibody marker (neuromyelitis optica –immunoglobulin G) differentiates neuromyelitis optica from other demyelinating disorders particularly in clinically challenging cases. We present a child with multiple episodes of transverse myelitis and optic neuritis with positive neuromyelitis optica-immunoglobulin G titers consistent with a diagnosis of relapsing neuromyelitis optica. Serial titers of ...

  11. Serum lipoprotein (a) concentration in patients with nephrotic syndrome and its clinical implication.

    Science.gov (United States)

    Yang, X; Wang, H; Zhu, Z; Deng, A

    1998-01-01

    Serum lipoprotein(a) [Lp(a)] concentration was determined in 42 patients with primary nephrotic syndrome (NS) and the relationships between Lp (a) and plasma lipids, apolipoproteins, serum creatinine (Scr), albumin, urinary proteins (Upro) were also analyzed. The results showed that: (1) serum Lp(a) concentrations in the patients with NS were higher than those in healthy controls; (2) the levels of serum Lp(a) were correlated positively with total cholesterol (TC), low density lipoprotein cholesterol (LDL-C), very low density lipoprotein cholesterol (VLDL-C), apolipoprotein B (Apo-B), Upros (Upro). It is concluded that the NS patients had the potential risk of suffering from coronary artery disease, glomerular sclerosis and thrombosis. The remission of NS may partially decrease the serum Lp(a) levels. Further studies are needed to explore the prevention and treatment of dislipedemia in patients with NS.

  12. Applied optics

    International Nuclear Information System (INIS)

    Orszag, A.; Antonetti, A.

    1988-01-01

    The 1988 progress report, of the Applied Optics laboratory, of the (Polytechnic School, France), is presented. The optical fiber activities are focused on the development of an optical gyrometer, containing a resonance cavity. The following domains are included, in the research program: the infrared laser physics, the laser sources, the semiconductor physics, the multiple-photon ionization and the nonlinear optics. Investigations on the biomedical, the biological and biophysical domains are carried out. The published papers and the congress communications are listed [fr

  13. Study of Serum Amylase and Serum Cholinesterase in Organophosphorus Poisoning

    Directory of Open Access Journals (Sweden)

    Sharan Badiger

    2016-04-01

    Full Text Available Background: Poisoning due to organophosphorus compounds is most commonly seen. Earlier plasma cholinesterase level was used to assess the severity of poisoning. Presently serum amylase is being recommended as a better indicator of severity. Aims and Objectives: To study plasma cholinesterase and serum amylase levels in acute organophosphorus and to correlate serum amylase levels with clinical severity and outcome. Material and Methods: A total of 80 patients in the study admitted to a tertiary care centre within 24 hours with a history of organophosphorus poisoning were included in study. Estimation of plasma cholinesterase and serum rd amylase was done at the time of admission, and on 3 th day and on 5 day. Results: Occurrence of organophosphorus poisoning was more common among age group 21-30 years and among males (57.5%. They were 25 (31.2% farmers, 23 (28.8% st u d e n ts, a n d 2 2 ( 2 7 . 5% h o u s ewi v e s. Monocrotophos (45.0% was commonly used compound. Mean value of plasma cholinesterase and serum amylase at admission are 3693 U/L, and 185.4 U/L. There was significant inhibition of plasma cholinesterase and elevation of serum amylase at th admission with return to normal values on 5 day. Conclusion: Plasma cholinesterase inhibition 200 U/L has been associated with poor prognosis and proneness to respiratory failure.

  14. Density Distributions of Cyclotrimethylenetrinitramines (RDX)

    International Nuclear Information System (INIS)

    Hoffman, D M

    2002-01-01

    As part of the US Army Foreign Comparative Testing (FCT) program the density distributions of six samples of class 1 RDX were measured using the density gradient technique. This technique was used in an attempt to distinguish between RDX crystallized by a French manufacturer (designated insensitive or IRDX) from RDX manufactured at Holston Army Ammunition Plant (HAAP), the current source of RDX for Department of Defense (DoD). Two samples from different lots of French IRDX had an average density of 1.7958 ± 0.0008 g/cc. The theoretical density of a perfect RDX crystal is 1.806 g/cc. This yields 99.43% of the theoretical maximum density (TMD). For two HAAP RDX lots the average density was 1.786 ± 0.002 g/cc, only 98.89% TMD. Several other techniques were used for preliminary characterization of one lot of French IRDX and two lot of HAAP RDX. Light scattering, SEM and polarized optical microscopy (POM) showed that SNPE and Holston RDX had the appropriate particle size distribution for Class 1 RDX. High performance liquid chromatography showed quantities of HMX in HAAP RDX. French IRDX also showed a 1.1 C higher melting point compared to HAAP RDX in the differential scanning calorimetry (DSC) consistent with no melting point depression due to the HMX contaminant. A second part of the program involved characterization of Holston RDX recrystallized using the French process. After reprocessing the average density of the Holston RDX was increased to 1.7907 g/cc. Apparently HMX in RDX can act as a nucleating agent in the French RDX recrystallization process. The French IRDX contained no HMX, which is assumed to account for its higher density and narrower density distribution. Reprocessing of RDX from Holston improved the average density compared to the original Holston RDX, but the resulting HIRDX was not as dense as the original French IRDX. Recrystallized Holston IRDX crystals were much larger (3-500 (micro)m or more) then either the original class 1 HAAP RDX or French

  15. Fluidic optics

    Science.gov (United States)

    Whitesides, George M.; Tang, Sindy K. Y.

    2006-09-01

    Fluidic optics is a new class of optical system with real-time tunability and reconfigurability enabled by the introduction of fluidic components into the optical path. We describe the design, fabrication, operation of a number of fluidic optical systems, and focus on three devices, liquid-core/liquid-cladding (L2) waveguides, microfluidic dye lasers, and diffraction gratings based on flowing, crystalline lattices of bubbles, to demonstrate the integration of microfluidics and optics. We fabricate these devices in poly(dimethylsiloxane) (PDMS) with soft-lithographic techniques. They are simple to construct, and readily integrable with microanalytical or lab-on-a-chip systems.

  16. Optical fibres

    CERN Document Server

    Geisler, J; Boutruche, J P

    1986-01-01

    Optical Fibers covers numerous research works on the significant advances in optical fibers, with particular emphasis on their application.This text is composed of three parts encompassing 15 chapters. The first part deals with the manufacture of optical fibers and the materials used in their production. The second part describes optical-fiber connectors, terminals and branches. The third part is concerned with the major optoelectronic components encountered in optical-communication systems.This book will be of value to research scientists, engineers, and patent workers.

  17. Atom optics

    International Nuclear Information System (INIS)

    Balykin, V. I.; Jhe, W.

    1999-01-01

    Atom optics, in analogy to neutron and electron optics, deals with the realization of as a traditional elements, such as lenes, mirrors, beam splitters and atom interferometers, as well as a new 'dissipative' elements such as a slower and a cooler, which have no analogy in an another types of optics. Atom optics made the development of atom interferometer with high sensitivity for measurement of acceleration and rotational possible. The practical interest in atom optics lies in the opportunities to create atom microprobe with atom-size resolution and minimum damage of investigated objects. (Cho, G. S.)

  18. Optical interconnects

    CERN Document Server

    Chen, Ray T

    2006-01-01

    This book describes fully embedded board level optical interconnect in detail including the fabrication of the thin-film VCSEL array, its characterization, thermal management, the fabrication of optical interconnection layer, and the integration of devices on a flexible waveguide film. All the optical components are buried within electrical PCB layers in a fully embedded board level optical interconnect. Therefore, we can save foot prints on the top real estate of the PCB and relieve packaging difficulty reduced by separating fabrication processes. To realize fully embedded board level optical

  19. Nonlinear optics

    CERN Document Server

    Boyd, Robert W

    2013-01-01

    Nonlinear Optics is an advanced textbook for courses dealing with nonlinear optics, quantum electronics, laser physics, contemporary and quantum optics, and electrooptics. Its pedagogical emphasis is on fundamentals rather than particular, transitory applications. As a result, this textbook will have lasting appeal to a wide audience of electrical engineering, physics, and optics students, as well as those in related fields such as materials science and chemistry.Key Features* The origin of optical nonlinearities, including dependence on the polarization of light* A detailed treatment of the q

  20. Serum leptin is correlated to high turnover in osteoporosis.

    Science.gov (United States)

    Hipmair, Gunter; Böhler, Nikolaus; Maschek, Wilma; Soriguer, Federico; Rojo-Martínez, Gemma; Schimetta, Wolfgang; Pichler, Robert

    2010-01-01

    Clinical data have suggested that obesity protects against osteoporosis. Leptin, mainly secreted by white adipose tissue, might be involved by mediating an effect on bone metabolism. This study was conducted to investigate a possible relationship of leptin and bone turn-over in postmenopausal women with osteoporosis. We measured bone mineral density (BMD), serum leptin levels and markers of bone metabolism, including osteocalcin and cross-laps in 44 patients with osteoporosis. The main group consisted of 32 postmenopausal women. Mean serum leptin was 13.1 microg/L and showed no statistically significant difference to the levels measured in a collective of normal persons adjusted for age and BMI. When related to serum cross-laps as markers of bone resorption, a positive correlation (posteoporosis.

  1. Correlation of serum magnesium with dyslipidemia in patients on maintenance hemodialysis

    Directory of Open Access Journals (Sweden)

    Muhammad Rafique Ansari

    2012-01-01

    Full Text Available This study was performed to determine the correlation between serum magnesium (Mg and dyslipidemia in patients on maintenance hemodialysis (MHD. This hospital-based cross-sectional observational study was conducted at the Department of Nephro-Urology, Liaquat University Hospital, Hyderabad, Pakistan, from April 2008 to June 2008. Fifty patients with end-stage kidney disease on MHD treatment (33 males and 17 females were studied. The mean duration on HD was 7.58 ± 2.05 years, with frequency being two to three sessions/week, and each session lasted for four hours. After obtaining informed written consent, the general information of each patient was recorded on a proforma. After overnight fasting, blood samples was drawn from the arterio-venous fistula for lipid profile, lipoprotein, serum Mg, serum creatinine, blood urea, serum calcium and serum phosphorus. Dyslipidemia was defined as presence of total cholesterol (TC, triglyceride (TG or low-density lipoprotein (LDL levels more then 95 th percentile for age and gender or high-density lipoprotein (HDL levels less then 35 mg/dL. Descriptive and inferential statistical analyses were performed using SPSS version 16.0. The mean age of the study patients was 45.68 ± 13.97 years. There was a significant positive correlation between serum Mg and serum lipoprotein-a (LP-a (r = 0.40, P < 0.007, serum HDL (r = 0.31, P < 0.01 and serum TG (r = 0.35, P < 0.005. There was no significant correlation between serum Mg and serum LDL-c and serum TC. The serum TG and LP-a levels were significantly increased while HDL-c was significantly lower in MHD patients. The serum TC, LDL-c and very low-density lipoprotein-c were not significantly elevated. We conclude that patients with chronic kidney disease undergoing MHD show positive correlation between serum Mg and serum HDL, LP-a and TG. The abnormalities of lipid metabolism, such as hyper-triglyceridemia, elevated LP-a and low HDL-c, could contribute to

  2. Serum lipids, apoproteins and nutrient intake in rural Cretan boys consuming high-olive-oil diets.

    NARCIS (Netherlands)

    Aravanis, C.; Mensink, R.P.; Karalias, N.; Christodoulou, B.; Kafatos, A.; Katan, M.B.

    1988-01-01

    A high intake of olive oil has produced high levels of high-density and low levels of low-density lipoprotein cholesterol in short-term dietary trials. To investigate long-term effects of olive oil we have studied the diet and serum lipids of boys in Crete, where a high olive oil consumption is the

  3. Changes in the serum profiles of lipids and cholesterol in sheep ...

    African Journals Online (AJOL)

    The samples were used for haematological and parasitological analyses and determination of serum concentrations of total cholesterol, triglycerides, high density lipoprotein-cholesterol (HDL-cholesterol) and low density lipoproteincholesterol (LDL-cholesterol). All animals in the infected group showed parasitaemia by day ...

  4. Laboratory Density Functionals

    OpenAIRE

    Giraud, B. G.

    2007-01-01

    We compare several definitions of the density of a self-bound system, such as a nucleus, in relation with its center-of-mass zero-point motion. A trivial deconvolution relates the internal density to the density defined in the laboratory frame. This result is useful for the practical definition of density functionals.

  5. Association between coffee consumption and serum lipid profile.

    Science.gov (United States)

    Karabudak, Efsun; Türközü, Duygu; Köksal, Eda

    2015-05-01

    The aim of the present study was to investigate the association between coffee consumption and serum lipid levels in a study population of 122 Turkish subjects (mean age, 41.4±12.69 years), including 48 males and 74 females. A questionnaire was compiled to determine baseline characteristics, and food and coffee consumption. Subjects were divided into three groups, which included non-drinkers, Turkish coffee and instant coffee drinkers, and anthropometric measurements were acquired, including weight, height and body mass index. Serum lipid levels were analyzed, including the total cholesterol (TC), triglyceride (TG), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and very low-density lipoprotein cholesterol (VLDL-C) levels. Of the population studied, 76.2% had consumed at least one cup of coffee per week over the previous year. Daily consumption values were 62.3±40.60 ml (0.7±0.50 cup) for Turkish coffee and 116.3±121.96 ml (0.7±0.81 cup) for instant coffee. No statistically significant differences were observed in the serum levels of TC, TG, LDL-C, HDL-C or VLDL-C among the three groups. In addition, no statistically significant differences were observed in the serum lipid levels when comparing individuals who consumed coffee with sugar/cream or who smoked and those who did not (P>0.05). Therefore, the present observations indicated no significant association between the consumption of Turkish or instant coffee and serum lipid levels.

  6. Applied optics and optical design

    CERN Document Server

    Conrady, Alexander Eugen

    1957-01-01

    ""For the optical engineer it is an indispensable work."" - Journal, Optical Society of America""As a practical guide this book has no rival."" - Transactions, Optical Society""A noteworthy contribution,"" - Nature (London)Part I covers all ordinary ray-tracing methods, together with the complete theory of primary aberrations and as much of higher aberration as is needed for the design of telescopes, low-power microscopes and simple optical systems. Chapters: Fundamental Equations, Spherical Aberration, Physical Aspect of Optical Images, Chromatic Aberration, Design of Achromatic Object-Glass

  7. Serum lipids and lipoproteins in patients with psoriasis.

    Science.gov (United States)

    Taheri Sarvtin, Mehdi; Hedayati, Mohammad Taghi; Shokohi, Tahereh; HajHeydari, Zohreh

    2014-05-01

    Psoriasis is a common chronic and recurrent inflammatory skin disorder characterized by hyperproliferation of keratinocytes and infiltration of T cells, monocytes/macrophages and neutrophils into dermal and epidermal layers of the skin. The prevalence of cardiovascular disorders in these patients is remarkably higher compared to normal individuals, which seems to be associated with the hyperlipidemia. This study was designed and conducted to investigate the serum lipid profile in psoriatic patients and its association with the severity of disease. This case-control study was performed on 50 plaque-type psoriasis patients and 50 healthy individuals as control, matched for age and sex. Blood samples were collected after 14 h fasting. Serum triglyceride, cholesterol and lipoproteins were assayed using the standard kit (made by Pars Azmon Co. Iran). Certain parameters, including serum triglyceride, cholesterol, low density lipoprotein (LDL), and very low density lipoprotein (VLDL), were significantly higher in the case group compared to the controls (P lipoprotein (HDL) was significantly lower in the former (P < 0.001). In addition, there was a significant relationship between severity of psoriasis and serum lipid profile. The results have revealed the higher plasma level of lipids in psoriatic patients. This may elevate the risk of atherosclerosis, particularly cardiovascular disorders. Therefore, from the epidemiological point of view, screening psoriatic patients, particularly those with severe psoriasis, is recommended.

  8. Sex-Specific Associations Between Thyrotropin and Serum Lipid Profiles

    DEFF Research Database (Denmark)

    Meisinger, Christa; Ittermann, Till; Tiller, Daniel

    2014-01-01

    BACKGROUND: Population-based studies investigating the sex-specific association between thyrotropin (TSH) levels and serum lipid concentrations are scarce. We examined the association between TSH and total cholesterol, low-density lipoprotein (LDL) cholesterol, high-density lipoprotein (HDL......) cholesterol, and triglycerides in men and women from the general population. Furthermore, the association with TSH outside and within the reference range and lipid levels was studied. METHODS: Individual data of 13,571 men and women without lipid medication of four population-based studies conducted...... in Western European adults were pooled for cross-sectional analyses. The association between TSH levels and lipid concentrations were analyzed by calculating sex-specific multivariable median regression models. RESULTS: In the pooled population, serum TSH levels were significantly positively associated...

  9. Deuteron microscopic optical model potential

    International Nuclear Information System (INIS)

    Guo Hairui; Han Yinlu; Shen Qingbiao; Xu Yongli

    2010-01-01

    A deuteron microscopic optical model potential is obtained by the Green function method through nuclear-matter approximation and local-density approximation based on the effective Skyrme interaction. The microscopic optical model potential is used to calculate the deuteron reaction cross sections and the elastic scattering angular distributions for some target nuclei in the mass range 6≤A≤208 with incident deuteron energies up to 200 MeV. The calculated results are compared with the experimental data.

  10. Digital radiographic evaluation of optical density of porcelains used for fabrication of inlay/onlay prosthesis Avaliação da densidade óptica de porcelanas usadas para confecção de próteses inlay/onlay por meio de radiografia digital

    Directory of Open Access Journals (Sweden)

    Júlio Cezar de Melo Castilho

    2006-01-01

    Full Text Available The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter: Empress (Ivoclair, Simbios (Degussa, Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik. The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al. The samples were X-rayed using two charge coupled devices (CCD - RVG (Trophy - Visualix (Gendex and a phosphor plate system - Digora (Soredex. The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p Objetivo desse trabalho é comparar valores médios de densidade óptica de quatro porcelanas comumente utilizadas para confecção de inlay/onlay por meio da densidade óptica usando radiografia digital. A amostra constou de 20 corpos de prova com espessura de 2mm (mensurados em paquímetro digital das porcelanas: Empress (Ivoclair, Simbios (Degussa, Vita Omega 900 e Vitadur Alpha (Vita Zahnfabrik. Os valores de densidade óptica das amostras foram expressos em milímetros equivalente em alumínio (mm eq Al. Os espécimes foram radiografados, utilizando dois sistemas de dispositivo de carga acoplada (CCD - RVG (Trophy - Visualix (Gendex e um sistema de placa de fósforo - Digora (Soredex. A leitura da densidade óptica foi realizada no programa Image Tool 1.28 totalizando 110 medições. As leituras de densidade ópticas foram feitas no programa Image Tool 1.28 totalizando 110 mensurações. A análise estatística demonstrou que houve diferença estatisticamente significante entre a densidade óptica das porcelanas estudadas independentemente do sistema de radiografia empregado (p < 0,05. A porcelana Omega 900 obteve 1,8988mmeq

  11. Interchip link system using an optical wiring method.

    Science.gov (United States)

    Cho, In-Kui; Ryu, Jin-Hwa; Jeong, Myung-Yung

    2008-08-15

    A chip-scale optical link system is presented with a transmitter/receiver and optical wire link. The interchip link system consists of a metal optical bench, a printed circuit board module, a driver/receiver integrated circuit, a vertical cavity surface-emitting laser/photodiode array, and an optical wire link composed of plastic optical fibers (POFs). We have developed a downsized POF and an optical wiring method that allows on-site installation with a simple annealing as optical wiring technologies for achieving high-density optical interchip interconnection within such devices. Successful data transfer measurements are presented.

  12. Size- and density-controlled deposition of Ag nanoparticle films by a novel low-temperature spray chemical vapour deposition method—research into mechanism, particle growth and optical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang, E-mail: yang.liu@helmholtz-berlin.de; Plate, Paul, E-mail: paul.plate@helmholtz-berlin.de; Hinrichs, Volker; Köhler, Tristan; Song, Min; Manley, Phillip; Schmid, Martina [Helmholtz-Zentrum Berlin für Materialien und Energie GmbH (Germany); Bartsch, Peter [Beuth Hochschule für Technik Berlin, Fachbereich VIII Maschinenbau, Veranstaltungstechnik, Verfahrenstechnik (Germany); Fiechter, Sebastian; Lux-Steiner, Martha Ch. [Helmholtz-Zentrum Berlin für Materialien und Energie GmbH (Germany); Fischer, Christian-Herbert [Freie Universität Berlin, Institute of Chemistry and Biochemistry (Germany)

    2017-04-15

    Ag nanoparticles have attracted interest for plasmonic absorption enhancement of solar cells. For this purpose, well-defined particle sizes and densities as well as very low deposition temperatures are required. Thus, we report here a new spray chemical vapour deposition method for producing Ag NP films with independent size and density control at substrate temperatures even below 100 °C, which is much lower than for many other techniques. This method can be used on different substrates to deposit Ag NP films. It is a reproducible, low-cost process which uses trimethylphosphine (hexafluoroacetylacetonato) silver as a precursor in alcoholic solution. By systematic variation of deposition parameters and classic experiments, mechanisms of particle growth and of deposition processes as well as the low decomposition temperature of the precursor could be explained. Using the 3D finite element method, absorption spectra of selected samples were simulated, which fitted well with the measured results. Hence, further applications of such Ag NP films for generating plasmonic near field can be predicted by the simulation.

  13. Size- and density-controlled deposition of Ag nanoparticle films by a novel low-temperature spray chemical vapour deposition method—research into mechanism, particle growth and optical simulation

    International Nuclear Information System (INIS)

    Liu, Yang; Plate, Paul; Hinrichs, Volker; Köhler, Tristan; Song, Min; Manley, Phillip; Schmid, Martina; Bartsch, Peter; Fiechter, Sebastian; Lux-Steiner, Martha Ch.; Fischer, Christian-Herbert

    2017-01-01

    Ag nanoparticles have attracted interest for plasmonic absorption enhancement of solar cells. For this purpose, well-defined particle sizes and densities as well as very low deposition temperatures are required. Thus, we report here a new spray chemical vapour deposition method for producing Ag NP films with independent size and density control at substrate temperatures even below 100 °C, which is much lower than for many other techniques. This method can be used on different substrates to deposit Ag NP films. It is a reproducible, low-cost process which uses trimethylphosphine (hexafluoroacetylacetonato) silver as a precursor in alcoholic solution. By systematic variation of deposition parameters and classic experiments, mechanisms of particle growth and of deposition processes as well as the low decomposition temperature of the precursor could be explained. Using the 3D finite element method, absorption spectra of selected samples were simulated, which fitted well with the measured results. Hence, further applications of such Ag NP films for generating plasmonic near field can be predicted by the simulation.

  14. Relationship Between Exposure to Industrial Noise and Serum Lipid Profile

    Directory of Open Access Journals (Sweden)

    Ramin Mehrdad

    2011-11-01

    Full Text Available Aim of our study was to investigate the effects of exposure to industrial noise on serum lipid profile among workers who are exposed to noise at work. In a historical cohort study, we recruited 154 and 146 male workers as high and low level noise exposure groups respectively. We defined workers with at least one year exposure to noise level more than 90 dB as high exposure group, and those with exposure to less than 80 dB as low exposure group. Afterwards, in the fasting blood specimens of participants we measured serum Triglyceride (TG, total Cholesterol (TC, high and low density lipoprotein (HDL and LDL. Mean of TG, TC, HDL and LDL for low exposure group were 148, 189, 38 and 103 mg/dl and for high exposure group were 237, 189, 37 and 104 mg/dl respectively. Mean serum TG between two groups was different. Even after adjustment for age, BMI, smoking and work hours per week, serum TG among high exposure group was 89 mg/dl higher than low exposure group and this difference was statistically significant (P=0.00. There was no significant difference between two groups in TC, LDL and HDL levels. This study did not find a statistically significant relationship between exposure to noise and serum TC, LDL and HDL, but TG in two groups was different and this difference was statistically significant.

  15. Scattering of ECRF waves by edge density fluctuations and blobs

    Directory of Open Access Journals (Sweden)

    Ram Abhay K.

    2015-01-01

    Full Text Available The scattering of electron cyclotron waves by density blobs embedded in the edge region of a fusion plasma is studied using a full-wave model. The full-wave theory is a generalization of the usual approach of geometric optics ray scattering by blobs. While the latter allows for only refraction of waves, the former, more general formulation, includes refraction, reflection, and diffraction of waves. Furthermore, the geometric optics, ray tracing, model is limited to blob densities that are slightly different from the background plasma density. Observations in tokamak experiments show that the fluctuating density differs from the background plasma density by 20% or more. Thus, the geometric optics model is not a physically realistic model of scattering of electron cyclotron waves by plasma blobs. The differences between the ray tracing approach and the full-wave approach to scattering are illustrated in this paper.

  16. Co-administration of trientine and flaxseed oil on oxidative stress, serum lipids and heart structure in diabetic rats.

    Science.gov (United States)

    Rezaei, Ali; Heidarian, Esfandiar

    2013-08-01

    The administration of flaxseed oil or flaxseed oil plus trientine in diabetic rats reduced triglyceride, very low density lipoprotein, and total cholesterol. Furthermore, the combined treatment significantly increased superoxide dismutase activity and attenuated serum Cu2+. The results suggest that the administration of flaxseed oil plus trientine is useful in controlling serum lipid abnormalities, oxidative stress, restoring heart structure, and reducing serum Cu2+ in diabetic rats.

  17. Optical electronics

    CERN Document Server

    Yariv, Amnon

    1991-01-01

    This classic text introduces engineering students to the first principles of major phenomena and devices of optoelectronics and optical communication technology. Yariv's "first principles" approach employs real-life examples and extensive problems. The text includes separate chapters on quantum well and semiconductor lasers, as well as phase conjugation and its applications. Optical fiber amplification, signal and noise considerations in optical fiber systems, laser arrays and distributed feedback lasers all are covered extensively in major sections within chapters.

  18. Serum-Sphingosine-1-Phosphate Concentrations Are Inversely Associated with Atherosclerotic Diseases in Humans.

    Directory of Open Access Journals (Sweden)

    Irina Soltau

    Full Text Available Atherosclerotic changes of arteries are the leading cause for deaths in cardiovascular disease and greatly impair patient's quality of life. Sphingosine-1-phosphate (S1P is a signaling sphingolipid that regulates potentially pro-as well as anti-atherogenic processes. Here, we investigate whether serum-S1P concentrations are associated with peripheral artery disease (PAD and carotid stenosis (CS.Serum was sampled from blood donors (controls, N = 174 and from atherosclerotic patients (N = 132 who presented to the hospital with either clinically relevant PAD (N = 102 or CS (N = 30. From all subjects, serum-S1P was measured by mass spectrometry and blood parameters were determined by routine laboratory assays. When compared to controls, atherosclerotic patients before invasive treatment to restore blood flow showed significantly lower serum-S1P levels. This difference cannot be explained by risk factors for atherosclerosis (old age, male gender, hypertension, hypercholesteremia, obesity, diabetes or smoking or comorbidities (Chronic obstructive pulmonary disease, kidney insufficiency or arrhythmia. Receiver operating characteristic curves suggest that S1P has more power to indicate atherosclerosis (PAD and CS than high density lipoprotein-cholesterol (HDL-C. In 35 patients, serum-S1P was measured again between one and six months after treatment. In this group, serum-S1P concentrations rose after treatment independent of whether patients had PAD or CS, or whether they underwent open or endovascular surgery. Post-treatment S1P levels were highly associated to platelet numbers measured pre-treatment.Our study shows that PAD and CS in humans is associated with decreased serum-S1P concentrations and that S1P may possess higher accuracy to indicate these diseases than HDL-C.

  19. Optical computing.

    Science.gov (United States)

    Stroke, G. W.

    1972-01-01

    Applications of the optical computer include an approach for increasing the sharpness of images obtained from the most powerful electron microscopes and fingerprint/credit card identification. The information-handling capability of the various optical computing processes is very great. Modern synthetic-aperture radars scan upward of 100,000 resolvable elements per second. Fields which have assumed major importance on the basis of optical computing principles are optical image deblurring, coherent side-looking synthetic-aperture radar, and correlative pattern recognition. Some examples of the most dramatic image deblurring results are shown.

  20. ZZ-CENPL, Chinese Evaluated Nuclear Parameter Library. ZZ CENPL-DLS, Discrete Level Schemes and Gamma Branching Ratios Library; ZZ CENPL-FBP, Fission Barrier Parameter Library; ZZ CENPL-GDRP, Giant Dipole Resonance Parameter Library; ZZ CENPL-NLD, Nuclear Level Density Parameter Library; ZZ CENPL-MCC, Nuclear Ground State Atomic Masses Library; ZZ CENPL-OMP, Optical Model Parameter Library

    International Nuclear Information System (INIS)

    Su Zongdi

    1995-01-01

    Description of program or function: CENPL - GDRP (Giant Dipole Resonance Parameters for Gamma-Ray): - Format: special format described in documentation; - Nuclides: V, Mn, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Rh, Pd, Ag, Cd, In, Sn, Sb, Te, I, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Ho, Er, Lu, Ta, W, Re, Os, Ir, Pt, Au, Hg, Pb, Bi, Th, U, Np, Pu. - Origin: Experimental values offered by S.S. Dietrich and B.L. Berman. CENPL - FBP (Fission Barrier Parameter Sub-Library): - Format: special format described in documentation; - Nuclides: (1) 51 nuclei region from Th-230 to Cf-255, (2) 46 nuclei region from Th-229 to Cf-253, (3) 24 nuclei region from Pa-232 to Cf-253; - Origin: (1) Lynn, (2) Analysis of experimental data by Back et al., (3) Ohsawa. CENPL - DLS (Discrete level scheme and branch ratio of gamma decay: - Format: Special format described in documentation; - Origin: ENSDF - BNL. CENPL - NLD (Nuclear Level Density): - Format: Special format described in documentation; - Origin: Huang Zhongfu et al. CENPL - OMP (Optical model parameter sub-library): - Format: special format described in documentation ; - Origin: CENDL, ENDF/B-VI, JENDL-3. CENPL - MC (I) and (II) (Atomic masses and characteristic constants for nuclear ground states) : - Format: Brief table format; - Nuclides: 4760 nuclides ranging from Z=0 A=1 to Z=122 A=318. - Origin: Experimental data and systematic results evaluated by Wapstra, theoretical results calculated by Moller, ENSDF - BNL and Nuclear Wallet Cards. CENPL contains the following six sub-libraries: 1. Atomic Masses and Characteristic Constants for nuclear ground states (MCC). This data consists of calculated and in most cases also measured mass excesses, atomic masses, total binding energies, spins, parities, and half-lives of nuclear ground states, abundances, etc. for 4800 nuclides. 2. Discrete Level Schemes and branching ratios of gamma decay (DLS). The data on nuclear discrete levels are based on the Evaluated

  1. Alveolar bone mass in pre- and postmenopausal women with serum calcium as a marker: A comparative study

    Directory of Open Access Journals (Sweden)

    Amitha Ramesh

    2011-01-01

    Conclusion: Postmenopausal women exhibit a reduced alveolar bone mass and lowered levels of serum total calcium with the increasing age. These changes may be useful indicators for low skeletal bone mineral density or osteoporosis.

  2. Laboratory Equipment Type Fiber Optic Refractometer

    Directory of Open Access Journals (Sweden)

    E. F. Carome

    2002-09-01

    Full Text Available Using fiber optics and micro optics technologies we designed aninnovative fiber optic index of refraction transducer that has uniqueproperties. On the base of this transducer a laboratory equipment typefiber optic refractometer was developed for liquid index of refractionmeasurements. Such refractometer may be used for medical,pharmaceutical, industrial fluid, petrochemical, plastic, food, andbeverage industry applications. For example, it may be used formeasuring the concentrations of aqueous solutions: as the concentrationor density of a solute increase, the refractive index increasesproportionately. The paper describes development work related to designof laboratory type fiber optic refractometer and describes experimentsto evaluation of its basic properties.

  3. Rabbit chondrocytes maintained in serum-free medium. I. Synthesis and secretion of hydrodynamically-small proteoglycans

    International Nuclear Information System (INIS)

    Malemud, C.J.; Papay, R.S.

    1986-01-01

    The biosynthesis of sulfated proteoglycan in vitro by rabbit articular chondrocytes in first passage monolayer culture maintained in fetal bovine serum (FBS) or in serum-free conditions was compared. Neosynthesized proteoglycan in the culture medium in the most dense fraction of an associative CsCl density gradient (fraction dAl) declined with increasing time under serum-free conditions, but not when cells were maintained in the presence of serum. After one day, the major peak of incorporated 35 SO 4 in medium fraction dAl eluted as a retarded peak on Sepharose CL-2B, whether cells were maintained under serum-free or serum-containing conditions. The hydrodynamic size of proteoglycan monomer fraction dAlDl obtained after one day of exposure to serum-free culture media was smaller than dAlDl from serum-containing cultures. The hydrodynamic size of dAlDl obtained from serum-free culture media became even progressively smaller after 2 and 3 days' exposure to these conditions. Hydrodynamically small sulfated proteoglycans were identified in the cell-associated dAlDl fraction as early as one day after switching chondrocytes from serum-containing to serum-free medium. Proteoglycan monomer from serum-containing medium reaggregated more efficiently under both conditions. No change in the size of glycosaminoglycan chains was seen in the smaller proteoglycan subpopulations, nor was there any indication of marked changes in the glycosaminoglycan types

  4. Micro-bead injection spectroscopy for label-free automated determination of immunoglobulin G in human serum.

    Science.gov (United States)

    Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A

    2018-01-01

    Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were time-to-result decreased from several hours to times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.

  5. Future Road Density

    Data.gov (United States)

    U.S. Environmental Protection Agency — Road density is generally highly correlated with amount of developed land cover. High road densities usually indicate high levels of ecological disturbance. More...

  6. Advanced infrared optically black baffle materials

    International Nuclear Information System (INIS)

    Seals, R.D.; Egert, C.M.; Allred, D.D.

    1990-01-01

    Infrared optically black baffle surfaces are an essential component of many advanced optical systems. All internal surfaces in advanced infrared optical sensors that require stray light management to achieve resolution are of primary concern in baffle design. Current industrial materials need improvements to meet advanced optical sensor systems requirements for optical, survivability, and endurability. Baffles are required to survive and operate in potentially severe environments. Robust diffuse-absorptive black surfaces, which are thermally and mechanically stable to threats of x-ray, launch, and in-flight maneuver conditions, with specific densities to allow an acceptable weight load, handleable during assembly, cleanable, and adaptive to affordable manufacturing, are required as optical baffle materials. In this paper an overview of recently developed advanced infrared optical baffle materials, requirements, manufacturing strategies, and the Optics MODIL (Manufacturing Operations Development and Integration Laboratory) Advanced Baffle Program are discussed

  7. Achieving maximum baryon densities

    International Nuclear Information System (INIS)

    Gyulassy, M.

    1984-01-01

    In continuing work on nuclear stopping power in the energy range E/sub lab/ approx. 10 GeV/nucleon, calculations were made of the energy and baryon densities that could be achieved in uranium-uranium collisions. Results are shown. The energy density reached could exceed 2 GeV/fm 3 and baryon densities could reach as high as ten times normal nuclear densities

  8. Optical Computing

    Indian Academy of Sciences (India)

    Other advantages of optics include low manufacturing costs, immunity to ... It is now possible to control atoms by trapping single photons in small, .... cement, and optical spectrum analyzers. ... risk of noise is further reduced, as light is immune to electro- ..... mode of operation including management of large multimedia.

  9. Crowding and Density

    Science.gov (United States)

    Design and Environment, 1972

    1972-01-01

    Three-part report pinpointing problems and uncovering solutions for the dual concepts of density (ratio of people to space) and crowding (psychological response to density). Section one, A Primer on Crowding,'' reviews new psychological and social findings; section two, Density in the Suburbs,'' shows conflict between status quo and increased…

  10. Quantum Optics

    CERN Document Server

    Walls, D F

    2007-01-01

    Quantum Optics gives a comprehensive coverage of developments in quantum optics over the past years. In the early chapters the formalism of quantum optics is elucidated and the main techniques are introduced. These are applied in the later chapters to problems such as squeezed states of light, resonance fluorescence, laser theory, quantum theory of four-wave mixing, quantum non-demolition measurements, Bell's inequalities, and atom optics. Experimental results are used to illustrate the theory throughout. This yields the most comprehensive and up-to-date coverage of experiment and theory in quantum optics in any textbook. More than 40 exercises helps readers test their understanding and provide practice in quantitative problem solving.

  11. Optical biosensors.

    Science.gov (United States)

    Damborský, Pavel; Švitel, Juraj; Katrlík, Jaroslav

    2016-06-30

    Optical biosensors represent the most common type of biosensor. Here we provide a brief classification, a description of underlying principles of operation and their bioanalytical applications. The main focus is placed on the most widely used optical biosensors which are surface plasmon resonance (SPR)-based biosensors including SPR imaging and localized SPR. In addition, other optical biosensor systems are described, such as evanescent wave fluorescence and bioluminescent optical fibre biosensors, as well as interferometric, ellipsometric and reflectometric interference spectroscopy and surface-enhanced Raman scattering biosensors. The optical biosensors discussed here allow the sensitive and selective detection of a wide range of analytes including viruses, toxins, drugs, antibodies, tumour biomarkers and tumour cells. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  12. Lagrangian optics

    CERN Document Server

    Lakshminarayanan, Vasudevan; Thyagarajan, K

    2002-01-01

    Ingeometrical optics, light propagation is analyzed in terms of light rays which define the path of propagation of light energy in the limitofthe optical wavelength tending to zero. Many features oflight propagation can be analyzed in terms ofrays,ofcourse, subtle effects near foci, caustics or turning points would need an analysis based on the wave natureoflight. Allofgeometric optics can be derived from Fermat's principle which is an extremum principle. The counterpart in classical mechanics is of course Hamilton's principle. There is a very close analogy between mechanics ofparticles and optics oflight rays. Much insight (and useful results) can be obtained by analyzing these analogies. Asnoted by H. Goldstein in his book Classical Mechanics (Addison Wesley, Cambridge, MA, 1956), classical mechanics is only a geometrical optics approximation to a wave theory! In this book we begin with Fermat's principle and obtain the Lagrangian and Hamiltonian pictures of ray propagation through various media. Given the ...

  13. Quadrature interferometry for plasma density measurements

    International Nuclear Information System (INIS)

    Warthen, B.J.; Shlachter, J.S.

    1995-01-01

    A quadrature interferometer has been used routinely in several pulsed power experiments to measure the line-averaged electron density. The optical source is a 30 mW, continuous wave Nd-YAG laser operating at 1,300 nm. The light is coupled directly to an optical fiber and split into reference and scene beams with a fiber splitter. The scene beam is transported to and from the plasma using single mode optical fibers up to 100 m in length. To simplify alignment through the plasma, the authors have used GRIN lenses on both the launch and receive sides of the single pass transmission diagnostic where this is possible. The return beam passes through a half-wave plate which is used to compensate for polarization rotation associated with slow (hour) time scale drift in the single mode fibers. The reference beam is sent through a quarter-wave plate to produce circular polarization; mixing of the reference and scene beams is accomplished using a non-polarizing beam splitter, and the interference signals are focused into additional fibers which relay the light to fast photodiodes. The quadrature optics allow for an unambiguous determination of the slope of the density changes at inflection points. All of the beam processing optics are located on a stable optical table which is remote and protected from the experiment. Final setup of the interferometer is facilitated by looking at the Lissajous figure generated from the two quadrature components. The authors have used this interferometer to diagnose the background density in the Pegasus-II power flow channel, to study the plasma plume generated in foil implosion experiments, to measure the plasma blowoff during implosions, and to understand the plasma formation mechanism in a fusion target plasma system

  14. Electronic structure of f1 actinide complexes. Pt. 3. Quasi-relativistic density functional calculations of the optical transition energies of PaX62-(X=F,Cl,Br,I)

    International Nuclear Information System (INIS)

    Kaltsoyannis, N.

    1998-01-01

    For pt.II see J. Organomet. Chem., vol.528, p.19, 1997. The four f→f transition energies of the single 5f-based electron of PaX 6 2- (X=F, Cl, Br, I) have been calculated using quasi-relativistic local density functional theory. Excellent agreement ( -1 ) between theory and experiment is obtained for PaCl 6 2- , PaBr 6 2- and PaI 6 2- by variation of the value of α in the Xα exchange-only functional. In contrast, more sophisticated calculational methods including non-local corrections fail to reproduce the experiments well. The PaF 6 2- results are less impressive (up to 1000 cm -1 discrepancy), possibly due to non-aufbau orbital occupations for certain values of α. The values of α employed lie in the range 0.79-0.85, somewhat higher than the most widely used value of 0.7. The theoretical basis for using such values is discussed. (orig.)

  15. Influence of serum percentage on the behavior of Wharton's jelly mesenchymal stem cells in culture.

    Science.gov (United States)

    Harmouch, C; El-Omar, R; Labrude, P; Decot, V; Menu, P; Kerdjoudj, H

    2013-01-01

    Mesenchymal stem cells (MSCs) are multipotent cells able to differentiate into several lineages with valuable applications in regenerative medicine. MSCs differentiation is highly dependent on physicochemical properties of the culture substrate, cell density and on culture medium composition. In this study, we assessed the influence of fetal bovine serum (FBS) level on Wharton's jelly (WJ)-MSCs behavior seeded on polyelectrolyte multilayer films (PEMF) made of four bilayers of poly-allylamine hydrochloride (PAH) as polycation and poly-styrene sulfonate (PSS) as polyanion. MSCs isolated from WJ by explants method were amplified until the third passage. Their phenotypic characterization was performed by flow cytometry analyses. MSCs were seeded on PEMF, in Endothelial growth medium-2 (EGM-2) supplemented by either 5% or 2% FBS. Cell's behavior was monitored for 20 days by optical microscopy and immunofluorescence. Until 2 weeks on glass slides, no difference was observed whatever the FBS percentage. Then with 5% FBS, MSCs formed three-dimensional spheroids on PSS/PAH after 20 days of culture with a nuclear aggregate. Whereas, with 2% FBS, these spheroids did not appear and cells grown in 2D conserved the fibroblast-like morphology. The decrease of FBS percentage from 5% to 2% avoids 3D cell spheroids formation on PAH/PSS. Such results could guide bioengineering towards building 2D structures like cell layers or 3D structures by increasing the osteogenic or chondrogenic differentiation potential of MSCs.

  16. Computer programs simplify optical system analysis

    Science.gov (United States)

    1965-01-01

    The optical ray-trace computer program performs geometrical ray tracing. The energy-trace program calculates the relative monochromatic flux density on a specific target area. This program uses the ray-trace program as a subroutine to generate a representation of the optical system.

  17. Lecithin intake and serum cholesterol.

    NARCIS (Netherlands)

    Knuiman, J.T.; Beynen, A.C.; Katan, M.B.

    1989-01-01

    To find out whether the consumption of lecithin has a more beneficial effect on serum cholesterol than does the consumption of equivalent amounts of polyunsaturated oils, we scrutinized 24 studies on the effect of supplementary lecithin intakes ranging from 1 to 54 mg/d. Most of the studies lacked

  18. Serum transferrin receptor in polycythemia.

    Science.gov (United States)

    Manteiga, R; Remacha, A F; Sardà, M P; Ubeda, J

    1998-10-01

    We measured serum transferrin receptor (sTfR) levels in 22 patients with polycythemia vera and in 26 cases of secondary polycythemia. In our study, raised sTfR levels in both polycythemia groups were related to iron deficiency.

  19. Serum zinc level in thalassemia

    International Nuclear Information System (INIS)

    Keikhaei, B.; Badavi, M.; Pedram, M.; Zandian, K.

    2010-01-01

    To compare serum zinc level between Thalassemia Major (TM) patients and normal population at Shafa Hospital in South West of Iran. A total of 25 male and 36 female of TM patients were enrolled in this study. Out of 61 patients thirty were treated by deferroxamine (DFO) and 31 were on the combination of DFO and deferiprone (DEF) protocol therapy. Sixty normal subjects of the matching age and gender were recruited as controls. From each patient and control group 2 ml of blood was taken in fasting condition. Cell blood count and serum zinc were carried out for both thalassemia patients and normal subjects. The mean age of patients and control group was 15+- 5 years. Mean serum zinc level was 68.97+- 21.12 mu g/dl, 78.10-28.50 mu g/dl, and 80.16+- 26.54 mu g/dl in the TM with DFO, TM with DFO + DEF combination protocol and control group respectively. There was no significant correlation between patients and control group. However 50 percent of TM with DFO, 38.7 percent of TM with DFO + DEF and 32.8 percent of control group had hypozincemia. Nearly 40 to 50 percent of TM patients and one third of normal subjects are suffering from hypozincemia. This study shows that low level of serum zinc is a health problem in both thalassemia patients and normal population in South West of Iran. (author)

  20. an optical tweezer based study

    Indian Academy of Sciences (India)

    Shankar Ghosh

    2006-11-12

    Nov 12, 2006 ... Liquid-Solid interface. Liquid-liquid interface. Shankar Ghosh. Motion of a sphere in an .... Bare mass of a colloidal sphere ∼ 10^15Kg. Note : The effective mass scales with viscosity and not with the density. Shankar Ghosh. Motion of a sphere in an oscillatory boundary layer: an optical tweezer based study ...

  1. Optical diagnostics for plasma etching

    NARCIS (Netherlands)

    Bisschops, T.H.J.; Kroesen, G.M.W.; Veldhuizen, van E.M.; de Zeeuw, C.J.H.; Timmermans, C.J.

    1985-01-01

    Several optical diagnostics were used to det. plasma properties and etch rates in an single wafer etch reactor. Results of UV-visible spectroscopy and IR absorption spectroscopy, indicating different mol. species and their densities are presented. The construction of an interferometer to det. the

  2. Low concentrator PV optics optimization

    Science.gov (United States)

    Sharp, Leonard; Chang, Ben

    2008-08-01

    Purpose: Cost reduction is a major focus of the solar industry. Thin film technologies and concentration systems are viable ways to reducing cost, with unique strengths and weakness for both. Most of the concentrating PV work focuses on high concentration systems for reducing energy cost. Meanwhile, many believe that low concentrators provide significant cost reduction potential while addressing the mainstream PV market with a product that acts as a flat panel replacement. This paper analyzes the relative benefit of asymmetric vs. symmetric optics for low-concentrators in light of specific PV applications. Approach: Symmetric and asymmetric concentrating PV module performance is evaluated using computer simulation to determine potential value across various geographic locations and applications. The selected optic design is modeled against standard cSi flat panels and thin film to determine application fit, system level energy density and economic value. Results: While symmetric designs may seem ideal, asymmetric designs have an advantage in energy density. Both designs are assessed for aperture, optimum concentration ratio, and ideal system array configuration. Analysis of performance across climate specific effects (diffuse, direct and circumsolar) and location specific effects (sunpath) are also presented. The energy density and energy production of low concentrators provide a compelling value proposition. More significantly, the choice of optics for a low concentrating design can affect real world performance. With the goal of maximizing energy density and return on investment, this paper presents the advantages of asymmetric optic concentration and illustrates the value of this design within specific PV applications.

  3. Laser produced plasma density measurement by Mach-Zehnder interferometry

    International Nuclear Information System (INIS)

    Vaziri, A.; Kohanzadeh, Y.; Mosavi, R.K.

    1976-06-01

    This report describes an optical interferometric method of measuring the refractive index of the laser-produced plasma, giving estimates of its electron density. The plasma is produced by the interaction of a high power pulsed CO 2 laser beam with a solid target in the vacuum. The time varying plasma has a transient electron density. This transient electron density gives rise to a changing plasma refractive index. A Mach-Zehnder ruby laser interferometer is used to measure this refractive index change

  4. Probability densities and Lévy densities

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler

    For positive Lévy processes (i.e. subordinators) formulae are derived that express the probability density or the distribution function in terms of power series in time t. The applicability of the results to finance and to turbulence is briefly indicated.......For positive Lévy processes (i.e. subordinators) formulae are derived that express the probability density or the distribution function in terms of power series in time t. The applicability of the results to finance and to turbulence is briefly indicated....

  5. Associations of Body Composition Measurements with Serum Lipid, Glucose and Insulin Profile: A Chinese Twin Study

    Science.gov (United States)

    Liao, Chunxiao; Gao, Wenjing; Cao, Weihua; Lv, Jun; Yu, Canqing; Wang, Shengfeng; Zhou, Bin; Pang, Zengchang; Cong, Liming; Wang, Hua; Wu, Xianping; Li, Liming

    2015-01-01

    Objectives To quantitate and compare the associations of various body composition measurements with serum metabolites and to what degree genetic or environmental factors affect obesity-metabolite relation. Methods Body mass index (BMI), waist circumference (WC), lean body mass (LBM), percent body fat (PBF), fasting serum high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), triglycerides (TG), total cholesterol (TC), glucose, insulin and lifestyle factors were assessed in 903 twins from Chinese National Twin Registry (CNTR). Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from fasting serum glucose and insulin. Linear regression models and bivariate structural equation models were used to examine the relation of various body composition measurements with serum metabolite levels and genetic/environmental influences on these associations, respectively. Results At individual level, adiposity measurements (BMI, WC and PBF) showed significant associations with serum metabolite concentrations in both sexes and the associations still existed in male twins when using within-MZ twin pair comparison analyses. Associations of BMI with TG, insulin and HOMA-IR were significantly stronger in male twins compared to female twins (BMI-by-sex interaction p = 0.043, 0.020 and 0.019, respectively). Comparison of various adiposity measurements with levels of serum metabolites revealed that WC explained the largest fraction of variance in serum LDL-C, TG, TC and glucose concentrations while BMI performed best in explaining variance in serum HDL-C, insulin and HOMA-IR levels. Of these phenotypic correlations, 64–81% were attributed to genetic factors, whereas 19–36% were attributed to unique environmental factors. Conclusions We observed different associations between adiposity and serum metabolite profile and demonstrated that WC and BMI explained the largest fraction of variance in serum lipid profile and insulin

  6. Computed tomography in optic neuritis

    International Nuclear Information System (INIS)

    Fujitani, Ken; Hakuba, Akira; Tsujimoto, Takeshi; Yasui, Toshihiro; Sakamoto, Hiroaki

    1979-01-01

    In two patients with optic neuritis, CT scans showed common features which were helpful in diagnosis. These consisted of an enlargement of the optic nerve and an increased density of the optic nerve after contrast infusion. A 49-year-old man was admitted with a two-week duration of pain and a progressive visual loss in his right eye. On admission, an enlarged central scotoma was noted, and only a flashlight was perceived at the periphery in the right eye. The right optic disc was swollen with perivascular bleeding. Plain skull radiographs and orbital tomographs were normal. An orbital CT scan, however, revealed an enlargement of the right optic nerve, the density of which was increased after the infusion of a contrast medium. After steroid therapy, the CT scan showed a normal optic nerve following improvement in the vision of the right eye. A 44-year-old man was referred to this hospital because of a visual loss in his right eye which had been noted one month before. The right eye, with a central scotoma, had only visual acuity enough to perceive hand motion. The right pupil responded poorly to light. The right optic disc was hyperemic. Plain skull radiographs were normal. The orbital CT scan, however, showed an enlargement of the right optic nerve and exhibited contrast enhancement. Steroid therapy resulted in an improvement of the visual disturbance, and a follow-up CT scan showed normal. Two months later, though, the visual acuity had decreased and a visual field defect was noted in his left eye. The orbital CT scan revealed an enlargement of the left optic nerve. The administration of steroid again improved the visual field defect in the left eye, and the CT scan again showed normal. (author)

  7. Quantum optics

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, P D [University of Queensland, St. Lucia, QLD (Australia).Physics Department

    1999-07-01

    Full text: Quantum optics in Australia has been an active research field for some years. I shall focus on recent developments in quantum and atom optics. Generally, the field as a whole is becoming more and more diverse, as technological developments drive experiments into new areas, and theorists either attempt to explain the new features, or else develop models for even more exotic ideas. The recent developments include quantum solitons, quantum computing, Bose-Einstein condensation, atom lasers, quantum cryptography, and novel tests of quantum mechanics. The talk will briefly cover current progress and outstanding problems in each of these areas. Copyright (1999) Australian Optical Society.

  8. Optical holography

    CERN Document Server

    Collier, Robert J; Lin, Lawrence H

    1971-01-01

    Optical Holography deals with the use of optical holography to solve technical problems, with emphasis on the properties of holograms formed with visible light. Topics covered include the Fourier transform, propagation and diffraction, pulsed-laser holography, and optical systems with spherical lenses. A geometric analysis of point-source holograms is also presented, and holograms and hologram spatial filters formed with spatially modulated reference waves are described. This book is comprised of 20 chapters and begins with an introduction to concepts that are basic to understanding hologr

  9. Nonlinear optics

    CERN Document Server

    Bloembergen, Nicolaas

    1996-01-01

    Nicolaas Bloembergen, recipient of the Nobel Prize for Physics (1981), wrote Nonlinear Optics in 1964, when the field of nonlinear optics was only three years old. The available literature has since grown by at least three orders of magnitude.The vitality of Nonlinear Optics is evident from the still-growing number of scientists and engineers engaged in the study of new nonlinear phenomena and in the development of new nonlinear devices in the field of opto-electronics. This monograph should be helpful in providing a historical introduction and a general background of basic ideas both for expe

  10. Relationship between subclinical hypothyroidism and serum homocysteine concentration in premenopausal women

    Directory of Open Access Journals (Sweden)

    Ayfer Aydoğdu Çolak

    2013-09-01

    Full Text Available Objective: In our study we aimed to examine serum homocysteinelevels of patients without thyroid dysfunctionswho have high serum anti thyroid peroxidase (anti-TPOlevels and patients with subclinical hypothyroidism whohave high serum thyroid stimulating hormone (TSH andanti-TPO levels.Methods: One hundred and seven premenopause femaleoutpatients who referred to endocrine clinic of our hospitalwere included in our study. We generated 3 groups. Firstgroup (Control consists of 53 (50% patients between theages of 30-40 years. Second group (Euthyroid consistsof 31 (29% patients between the ages of 26-49. Thirdgroup (Subclinical Hypothyroidism consists of 23 (21%patients between the ages of 33-53 years. Serum totalcholesterol, triglycerides, high density lipoprotein (HDLlevels were measured by Olympus 2700 autoanalyzer.Serum TSH, free T4, anti-TPO and homocysteine levelswere measured by Siemens Immulite 2000 autoanalyzer.Results: In our study, total cholesterol, triglycerides, lowdensity lipoprotein (LDL and very low density lipoprotein(VLDL levels were not statistically significantly differentamong the groups. Although serum homocysteine levelsof the third group were higher than the other groups it wasnot statistically significantly different among the groups.Conclusion: Serum homocysteine and lipid levels of patientswith euthyroidism and subclinical hypothyroidismwho have positive anti-TPO levels may be inadequate inassessing the risk of cardiovascular diseases. J Clin ExpInvest 2013; 4 (3: 293-297Key words: Hypothyroidsm, homocysteine, premenopause

  11. Quantum optics

    National Research Council Canada - National Science Library

    Agarwal, G. S

    2013-01-01

    ..., quantum metrology, spin squeezing, control of decoherence and many other key topics. Readers are guided through the principles of quantum optics and their uses in a wide variety of areas including quantum information science and quantum mechanics...

  12. Optical probe

    International Nuclear Information System (INIS)

    Denis, J.; Decaudin, J.M.

    1984-01-01

    The probe includes optical means of refractive index n, refracting an incident light beam from a medium with a refractive index n1>n and reflecting an incident light beam from a medium with a refractive index n2 [fr

  13. Serum PSA levels in the Indian population: Is it different?

    Science.gov (United States)

    Agrawal, Amit; Karan, Shailesh Chandra

    2017-04-01

    Serum prostate-specific antigen (PSA) is an important tumour, marker which is widely used to trigger trans-rectal ultrasound (TRUS)-guided prostate biopsy. However, the PSA levels vary with race and ethnicity. Therefore, there is a need to have an Indian reference range. All adult male patients meeting the inclusion and exclusion criteria were enrolled in this study. They were subjected to assessment of serum total PSA, digital rectal examination and trans-abdominal ultrasound. If any one or more of these were found abnormal, then a TRUS-guided 12-core prostate biopsy was done. Patients who were detected to have prostatic cancer were excluded from the final analysis. The data so obtained was grouped among the following three age groups: 40-49, 50-59 and 60-70 years, and the age-specific PSA values, prostatic volume and PSA density were found. A total of 1772 patients were analysed. The mean serum total PSA was 1.76 ng/ml with a standard deviation of 2.566 ng/ml. Group-wise age distribution of the mean serum total PSA was 1.22, 1.97 and 2.08 ng/ml in 40-49, 50-59 and 60-70 years age groups. The mean total PSA and the age-specific PSA range tend to be lower in the Indians than the Western population.

  14. Quantum optics

    DEFF Research Database (Denmark)

    Andersen, Ulrik Lund

    2013-01-01

    Further sensitivity improvements are required before advanced optical interferometers will be able to measure gravitational waves. A team has now shown that introducing quantum squeezing of light may help to detect these elusive waves.......Further sensitivity improvements are required before advanced optical interferometers will be able to measure gravitational waves. A team has now shown that introducing quantum squeezing of light may help to detect these elusive waves....

  15. Optically pumped polarized H- ion source

    International Nuclear Information System (INIS)

    Anderson, L.W.

    1986-01-01

    The current status and future prospects for the optically pumped polarized H - ion source are discussed. At the present time H - ion currents of 60 μA and with a polarization of 65% have been produced. The ion current and polarization can be increased significantly if the optically pumped Na charge exchange target density and polarization can be increased. Studies of wall surfaces that permit many bounces before depolarizing the Na electron spin and studies of radiation trapping in optically pumped Na indicate that the Na target density and polarization can be increased substantially. 27 refs., 6 figs., 2 tabs

  16. Why Density Dependent Propulsion?

    Science.gov (United States)

    Robertson, Glen A.

    2011-01-01

    In 2004 Khoury and Weltman produced a density dependent cosmology theory they call the Chameleon, as at its nature, it is hidden within known physics. The Chameleon theory has implications to dark matter/energy with universe acceleration properties, which implies a new force mechanism with ties to the far and local density environment. In this paper, the Chameleon Density Model is discussed in terms of propulsion toward new propellant-less engineering methods.

  17. Density limits in Tokamaks

    International Nuclear Information System (INIS)

    Tendler, M.

    1984-06-01

    The energy loss from a tokamak plasma due to neutral hydrogen radiation and recycling is of great importance for the energy balance at the periphery. It is shown that the requirement for thermal equilibrium implies a constraint on the maximum attainable edge density. The relation to other density limits is discussed. The average plasma density is shown to be a strong function of the refuelling deposition profile. (author)

  18. Nuclear Level Densities

    International Nuclear Information System (INIS)

    Grimes, S.M.

    2005-01-01

    Recent research in the area of nuclear level densities is reviewed. The current interest in nuclear astrophysics and in structure of nuclei off of the line of stability has led to the development of radioactive beam facilities with larger machines currently being planned. Nuclear level densities for the systems used to produce the radioactive beams influence substantially the production rates of these beams. The modification of level-density parameters near the drip lines would also affect nucleosynthesis rates and abundances

  19. Radioimmunoassay of apolipoprotein A-I of rat serum

    International Nuclear Information System (INIS)

    Fainaru, M.; Havel, R.J.; Felker, T.E.

    1976-01-01

    A double antibody radioimmunoassay technique was developed for quantification of apolipoprotein A-I, the major apoprotein of rat high density lipoprotein. Apo A-I was labelled with 125 I by the chloramine-T method. 125 I-labeled apo A-I had the same electrophoretic mobility as unlabeled apo A-I and more than 80% of the 125 I was precipitated by rabbit anti apo A-I antibodies. The assay is sensitive at the level of 0.5-5 ng, and has intraassay and interassay coefficients of variation of 4.5 and 6.5% respectively. The specificity of the assay was established by competitive displacement of 125 I-labeled apo A-I from its antibody by apo A-I and lipoproteins containing apo A-I, but not by rat albumin and other apoproteins. Immunoreactivity of high density lipoprotein and serum was only about 35% of that of their delipidated forms when Veronal buffer was used as a diluent. Inclusion of 5 mM sodium decyl sulfate in the incubation mixture brought out reactivity equivalent to that found after delipidation. Completeness of the reaction was verified by comparison with the amount of apo A-I in chromatographic fractions of the total apoprotein of high density lipoprotein. Content (weight %, mean values +- S.D.) of immunoassayable apo A-I was: 62.3 +- 5.9 in high density lipoprotein; 1.7 +- 0.3 in low density lipoprotein; 0.09 +- 0.03 in very low density lipoprotein and 25.0 +- 5.0 in lymph chylomicrons. Concentration in whole serum was 51.4 +- 8.9 mg/dl and 33.6 +- 4.1 mg/dl for female and male rats, respectively (p 1.21 g/ml and <1% in lipoproteins of d<1.063 g/ml

  20. Isospin-dependent term in the relativistic microscopic optical potential

    International Nuclear Information System (INIS)

    Rong Jian; Ma Zhongyu; National Laboratory of Heavy Ion Accelerator of Lanzhou, Lanzhou; Chinese Academy of Sciences, Beijing

    2005-01-01

    The isospin-dependence of the relativistic microscopic optical potential is investigated in the Dirac Brueckner-Hartree-Fock approach. The isospin part of the microscopic optical potential is emphasized. A local density approximation is adopted for finite nuclei. Taking 208 Pb as example, the difference between proton and neutron optical potentials is studied and compared with the phenomenological Lane Model potential. (authors)