WorldWideScience

Sample records for serum neutralization assay

  1. Bluetongue virus: comparative evaluation of enzyme-linked immunosorbent assay, immunodiffusion, and serum neutralization for detection of viral antibodies.

    OpenAIRE

    Poli, G; Stott, J; Liu, Y S; Manning, J S

    1982-01-01

    Comparative studies on the detection of bovine serum immunoglobulin G antibodies to bluetongue virus with an enzyme-linked immunosorbent assay, an immunodiffusion method, and a serum neutralization assay demonstrated complete concordance between the enzyme-linked immunosorbent assay and the serum neutralization assay results. However, the immunodiffusion method failed to detect bluetongue virus antibody in a substantial number of sera found to possess bluetongue virus immunoglobulin G with th...

  2. A novel, colorimetric neutralization assay for measuring antibodies to influenza viruses.

    Science.gov (United States)

    Lehtoranta, Liisa; Villberg, Anja; Santanen, Riitta; Ziegler, Thedi

    2009-08-01

    A colorimetric cell proliferation assay for measuring neutralizing antibodies to influenza viruses in human sera is described. Following a 90-min incubation, the serum-virus mixture was transferred to Madin-Darby canine kidney cells cultured in 96-well plates. After further incubation for three days, a tetrazolium salt was added to the wells. Cellular mitochondrial dehydrogenases cleave the tetrazolium salt to formazan, and the resulting color change is read by a spectrophotometer. The absorbance values correlate directly to the number of viable cells in the assay well and thus also to the neutralizing activity of influenza-specific antibodies present in the serum. With the few hands-on manipulations required, this assay allows simultaneous testing of a considerable number of sera, offers opportunities for automation, and is suitable for use under biosafety level-3 conditions. The test was used to study the antibody response after the administration of seasonal, inactivated, trivalent influenza vaccine. Antibody titers determined by the neutralization test in pre- and post-vaccination serum pairs were compared with those obtained by the hemagglutination inhibition assay. The neutralization test yielded higher pre- and post-vaccination titers and a larger number of significant increases in post-vaccination antibody titer than the hemagglutination inhibition test. This new test format could serve as a valuable laboratory tool for influenza vaccine studies.

  3. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    Science.gov (United States)

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  4. EL4 cell-based colorimetric toxin neutralization activity assays for determination of neutralizing anti-ricin antibodies.

    Science.gov (United States)

    Lindsey, Changhong Y; Brown, J Edward; Torabazar, Nahid R; Smith, Leonard A

    2013-01-01

    A recombinant ricin toxin A-chain 1-33/44-198 vaccine (RVEc), developed at the United States Army Medical Research Institute of Infectious Diseases as a vaccine candidate, is under investigation in a phase 1 clinical study. To effectively evaluate the immunogenicity of this ricin vaccine and to eliminate the use of radioactive material, an EL4 cell-based colorimetric toxin neutralization activity (TNA) assay using a CellTiter 96 AQueous One Solution Cell Proliferation Assay Reagent has been developed, optimized, and applied in the vaccine efficacy studies. The TNA assay measures the protective neutralizing anti-ricin antibodies in animal sera by determining the cell viability after ricin exposure in the assay system and comparing it to a purified mouse polyclonal antiricin IgG standard curve. The standard curve of the anti-ricin TNA assay closely fits a four-parameter logistic regression model. The unknown test sample concentration was expressed as microg/mL, but not the 50% effective concentration (EC50), which was determined by most TNA assays. The neutralizing endpoint titers, not the 50% effective dilution (ED50), of human specimens were measured with the TNA assay in support of the clinical study of the RVEc vaccine. The optimal amount of ricin toxin, EL4 cells, and concentration of standards used in the assay system was established to minimize false-negative and false-positive results of serum specimens from the nonclinical and clinical studies of RVEc. The testing conditions were adjusted to optimize assay performance. The colorimetric TNA assay replaced a radioactive TNA assay previously used in the ricin vaccine studies.

  5. A safe and reliable neutralization assay based on pseudovirus to measure neutralizing antibody titer against poliovirus.

    Science.gov (United States)

    Liu, Shaohua; Song, Dongmei; Bai, Han; Lu, Weiwei; Dai, Xinxian; Hao, Chunsheng; Zhang, Zhongyang; Guo, Huijie; Zhang, Yue; Li, Xiuling

    2017-12-01

    With the promotion of inactivated poliomyelitis vaccine (IPV) and live attenuated oral poliomyelitis vaccine (OPV), the global reported cases of poliomyelitis have reduced sharply from 0.35 million in 1988 to 74 in 2015. The Polio Eradication & Endgame Strategic Plan published by WHO in 2013 included the strategy of implementation of poliovirus safe handling and containment measures to minimize the risks of facility-associated reintroduction of virus into the polio-free community to prevent the re-import of poliovirus. Toward this strategy, we produced replication-incompetent pseudovirus of poliovirus type 1, 2, 3 attenuated strains by constructing poliovirus capsid expression vectors and poliovirus replicon then transfecting HEK293T cells and developed a pseudovirus-based neutralization assay (pNA) to determine neutralizing antibody titer which is more secure, time-saving and reliable than conventional neutralization assay (cNA). By using anti-poliovirus rat serum, we demonstrated excellent correlation between neutralizing antibody titers measured by cNA and pNA. It was concluded that pNA can be a potential alternative to replace cNA as a safe and time-saving system for titer determination after live poliovirus's safekeeping. © 2017 Wiley Periodicals, Inc.

  6. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  7. Determination of low tetanus or diphtheria antitoxin titers in sera by a toxin neutralization assay and a modified toxin-binding inhibition test

    Directory of Open Access Journals (Sweden)

    M.H. Sonobe

    2007-01-01

    Full Text Available A method for the screening of tetanus and diphtheria antibodies in serum using anatoxin (inactivated toxin instead of toxin was developed as an alternative to the in vivo toxin neutralization assay based on the toxin-binding inhibition test (TOBI test. In this study, the serum titers (values between 1.0 and 19.5 IU measured by a modified TOBI test (Modi-TOBI test and toxin neutralization assays were correlated (P < 0.0001. Titers of tetanus or diphtheria antibodies were evaluated in serum samples from guinea pigs immunized with tetanus toxoid, diphtheria-tetanus or triple vaccine. For the Modi-TOBI test, after blocking the microtiter plates, standard tetanus or diphtheria antitoxin and different concentrations of guinea pig sera were incubated with the respective anatoxin. Twelve hours later, these samples were transferred to a plate previously coated with tetanus or diphtheria antitoxin to bind the remaining anatoxin. The anatoxin was then detected using a peroxidase-labeled tetanus or diphtheria antitoxin. Serum titers were calculated using a linear regression plot of the results for the corresponding standard antitoxin. For the toxin neutralization assay, L+/10/50 doses of either toxin combined with different concentrations of serum samples were inoculated into mice for anti-tetanus detection, or in guinea pigs for anti-diphtheria detection. Both assays were suitable for determining wide ranges of antitoxin levels. The linear regression plots showed high correlation coefficients for tetanus (r² = 0.95, P < 0.0001 and for diphtheria (r² = 0.93, P < 0.0001 between the in vitro and the in vivo assays. The standardized method is appropriate for evaluating titers of neutralizing antibodies, thus permitting the in vitro control of serum antitoxin levels.

  8. Two different mutations in the envelope protein of feline immunodeficiency virus allow the virus to escape from neutralization by feline serum antibodies.

    NARCIS (Netherlands)

    C.H.J. Siebelink (Kees); M.L. Bosch (Marnix); G.F. Rimmelzwaan (Guus); R.H. Meloen; A.D.M.E. Osterhaus (Albert)

    1995-01-01

    textabstractViral progeny of two molecular clones of feline immunodeficiency virus (FIV), 19k1 and 19k32, were tested in a virus neutralization assay. In this assay the infection of thymocytes with FIV19k1 was neutralized by serum S1422, derived from an SPF cat 22 weeks after infection with FIV19k1.

  9. Detection by radioimmunoassay and enzyme-linked immunosorbent assay of coronavirus antibodies in bovine serum and lacteal secretions.

    Science.gov (United States)

    Rodak, L; Babiuk, L A; Acres, S D

    1982-07-01

    The sensitivity of a radioimmunoassay (RIA), an enzyme-linked immunosorbent assay (ELISA), and a serum neutralization assay (SN) for detecting antibodies to bovine coronavirus in serum and colostrum were compared. Although there proved to be a good correlation among all three assays (r = 0.915 and 0.964 for RIA with SN and ELISA, respectively), RIA and ELISA proved to be at least 10 times more sensitive than neutralization tests. By using these techniques, it was possible to detect a time-dependent decrease in antibody levels in bovine colostrum after parturition. Using ELISA, we demonstrated that 12 of 12 herds in Saskatchewan, and 109 of 110 animals tested, and antibody to bovine coronavirus. There was no elevated antibody response in serum or lacteal secretions of cows vaccinated once or twice with a commercially available modified live rota-coronavirus vaccine. In addition to being more sensitive than SN, ELISA and RIA proved to have other advantages for measuring antibody levels to bovine coronavirus and therefore warrant wider use as tools in diagnostic virology.

  10. Optimization and validation of a neutralizing antibody assay for HIV-1 in A3R5 cells.

    Science.gov (United States)

    Sarzotti-Kelsoe, Marcella; Daniell, Xiaoju; Todd, Christopher A; Bilska, Miroslawa; Martelli, Amanda; LaBranche, Celia; Perez, Lautaro G; Ochsenbauer, Christina; Kappes, John C; Rountree, Wes; Denny, Thomas N; Montefiori, David C

    2014-07-01

    A3R5 is a human CD4(+) lymphoblastoid cell line that was engineered to express CCR5 and is useful for the detection of weak neutralizing antibody responses against tier 2 strains of HIV-1. Here we describe the optimization and validation of the HIV-1 neutralizing antibody assay that utilizes A3R5 cells, performed in compliance with Good Clinical Laboratory Practice (GCLP) guidelines. The assay utilizes Renilla luciferase-expressing replication competent infectious molecular clones (IMC) encoding heterologous env genes from different HIV-1 clades. Key assay validation parameters tested included specificity, accuracy, precision, limit of detection and quantitation, specificity, linearity and range, and robustness. Plasma samples demonstrated higher non-specific activity than serum samples in the A3R5 assay. This assay can tolerate a wide range of virus input but is more sensitive to cell concentration. The higher sensitivity of the A3R5 assay in neutralization responses to tier 2 strains of HIV-1 makes it complementary to, but not a substitute for the TZM-bl assay. The validated A3R5 assay is employed as an endpoint immunogenicity test for vaccine-elicited neutralizing antibodies against tier 2 strains of HIV-1, and to identify correlates of protection in HIV-1 vaccine trials conducted globally. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Myostatin inhibitors in sports drug testing: Detection of myostatin-neutralizing antibodies in plasma/serum by affinity purification and Western blotting.

    Science.gov (United States)

    Walpurgis, Katja; Thomas, Andreas; Schänzer, Wilhelm; Thevis, Mario

    2016-02-01

    Myostatin is a key regulator of skeletal muscle growth and inhibition of its signaling pathway results in an increased muscle mass and function. The aim of this study was to develop a qualitative detection assay for myostatin-neutralizing antibodies for doping control purposes by using immunological approaches. To detect different types of myostatin-neutralizing antibodies irrespective of their amino acid sequence, an immunological assay specific for antibodies directed against myostatin and having a human Fc domain was established. Affinity purification and Western blotting strategies were combined to allow extracting and identifying relevant analytes from 200 μL of plasma/serum in a non-targeted approach. The assay was characterized regarding specificity, linearity, precision, robustness, and recovery. The assay was found to be highly specific, robust, and linear from 0.1 to 1 μg/mL. The precision was successfully specified at three different concentrations and the recovery of the affinity purification was 58%. Within this study, an immunological detection assay for myostatin-neutralizing antibodies present in plasma/serum specimens was developed and successfully characterized. The presented approach can easily be modified to include other therapeutic antibodies and serves as proof-of-concept for the detection of antibody-based myostatin inhibitors in doping control samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Neutralization of X4- and R5-tropic HIV-1 NL4-3 variants by HOCl-modified serum albumins

    Directory of Open Access Journals (Sweden)

    Schwalbe Birco

    2010-06-01

    Full Text Available Abstract Background Myeloperoxidase (MPO, an important element of the microbicidal activity of neutrophils, generates hypochlorous acid (HOCl from H2O2 and chloride, which is released into body fluids. Besides its direct microbicidal activity, HOCl can react with amino acid residues and HOCl-modified proteins can be detected in vivo. Findings This report is based on binding studies of HOCl-modified serum albumins to HIV-1 gp120 and three different neutralization assays using infectious virus. The binding studies were carried out by surface plasmon resonance spectroscopy and by standard ELISA techniques. Virus neutralization assays were carried out using HIV-1 NL4-3 virus and recombinant strains with CXCR4 and CCR5 coreceptor usage. Viral infection was monitored by a standard p24 or X-gal staining assay. Our data demonstrate that HOCl-modified mouse-, bovine- and human serum albumins all bind to the HIV-1 NL4-3 gp120 (LAV glycoprotein in contrast to non-modified albumin. Binding of HOCl-modified albumin to gp120 correlated to the blockade of CD4 as well as that of V3 loop specific monoclonal antibody binding. In neutralization experiments, HOCl-modified serum albumins inhibited replication and syncytium formation of the X4- and R5-tropic NL4-3 isolates in a dose dependent manner. Conclusions Our data indicate that HOCl-modified serum albumin veils the binding site for CD4 and the V3 loop on gp120. Such masking of the viral gp120/gp41 envelope complex might be a simple but promising strategy to inactivate HIV-1 and therefore prevent infection when HOCl-modified serum albumin is applied, for example, as a topical microbicide.

  13. Contribution of murine innate serum inhibitors toward interference within influenza virus immune assays.

    Science.gov (United States)

    Cwach, Kevin T; Sandbulte, Heather R; Klonoski, Joshua M; Huber, Victor C

    2012-03-01

    Prior to detection of an antibody response toward influenza viruses using the hemagglutination inhibition assay (HAI), sera are routinely treated to inactivate innate inhibitors using both heat inactivation (56°C) and recombinant neuraminidase [receptor-destroying enzyme (RDE)]. We revisited the contributions of innate serum inhibitors toward interference with influenza viruses in immune assays, using murine sera, with emphasis on the interactions with influenza A viruses of the H3N2 subtype. We used individual serum treatments: 56°C alone, RDE alone, or RDE + 56°C, to treat sera prior to evaluation within HAI, microneutralization, and macrophage uptake assays. Our data demonstrate that inhibitors present within untreated murine sera interfere with the HAI assay in a manner that is different from that seen for the microneutralization assay. Specifically, the γ class inhibitor α(2) -Macroglobulin (A2-M) can inhibit H3N2 viruses within the HAI assay, but not in the microneutralization assay. Based on these findings, we used a macrophage uptake assay to demonstrate that these inhibitors can increase uptake by macrophages when the influenza viruses express an HA from a 1968 H3N2 virus isolate, but not a 1997 H3N2 isolate. The practice of treating sera to inactivate innate inhibitors of influenza viruses prior to evaluation within immune assays has allowed us to effectively detect influenza virus-specific antibodies for decades. However, this practice has yielded an under-appreciation for the contribution of innate serum inhibitors toward host immune responses against these viruses, including contributions toward neutralization and macrophage uptake. © 2011 Blackwell Publishing Ltd.

  14. LabKey Server NAb: A tool for analyzing, visualizing and sharing results from neutralizing antibody assays

    Directory of Open Access Journals (Sweden)

    Gao Hongmei

    2011-05-01

    Full Text Available Abstract Background Multiple types of assays allow sensitive detection of virus-specific neutralizing antibodies. For example, the extent of antibody neutralization of HIV-1, SIV and SHIV can be measured in the TZM-bl cell line through the degree of luciferase reporter gene expression after infection. In the past, neutralization curves and titers for this standard assay have been calculated using an Excel macro. Updating all instances of such a macro with new techniques can be unwieldy and introduce non-uniformity across multi-lab teams. Using Excel also poses challenges in centrally storing, sharing and associating raw data files and results. Results We present LabKey Server's NAb tool for organizing, analyzing and securely sharing data, files and results for neutralizing antibody (NAb assays, including the luciferase-based TZM-bl NAb assay. The customizable tool supports high-throughput experiments and includes a graphical plate template designer, allowing researchers to quickly adapt calculations to new plate layouts. The tool calculates the percent neutralization for each serum dilution based on luminescence measurements, fits a range of neutralization curves to titration results and uses these curves to estimate the neutralizing antibody titers for benchmark dilutions. Results, curve visualizations and raw data files are stored in a database and shared through a secure, web-based interface. NAb results can be integrated with other data sources based on sample identifiers. It is simple to make results public after publication by updating folder security settings. Conclusions Standardized tools for analyzing, archiving and sharing assay results can improve the reproducibility, comparability and reliability of results obtained across many labs. LabKey Server and its NAb tool are freely available as open source software at http://www.labkey.com under the Apache 2.0 license. Many members of the HIV research community can also access the Lab

  15. International network for comparison of HIV neutralization assays: the NeutNet report.

    Science.gov (United States)

    Fenyö, Eva Maria; Heath, Alan; Dispinseri, Stefania; Holmes, Harvey; Lusso, Paolo; Zolla-Pazner, Susan; Donners, Helen; Heyndrickx, Leo; Alcami, Jose; Bongertz, Vera; Jassoy, Christian; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Sattentau, Quentin; Schuitemaker, Hanneke; Sutthent, Ruengpung; Wrin, Terri; Scarlatti, Gabriella

    2009-01-01

    Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet) involving 18 independent participants was organized to compare different assays. Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4) at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (virus infectivity assays, VI assays), or their Env-pseudotyped (gp160) derivatives produced in 293T cells (PSV assays) from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression. PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent. The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of neutralizing

  16. International network for comparison of HIV neutralization assays: the NeutNet report.

    Directory of Open Access Journals (Sweden)

    Eva Maria Fenyö

    Full Text Available Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1 vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration (NeutNet involving 18 independent participants was organized to compare different assays.Each laboratory evaluated four neutralizing reagents (TriMab, 447-52D, 4E10, sCD4 at a given range of concentrations against a panel of 11 viruses representing a wide range of genetic subtypes and phenotypes. A total of 16 different assays were compared. The assays utilized either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (virus infectivity assays, VI assays, or their Env-pseudotyped (gp160 derivatives produced in 293T cells (PSV assays from molecular clones or uncloned virus. Target cells included PBMC and genetically-engineered cell lines in either a single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs that included extracellular or intracellular p24 antigen detection, RNA quantification and luciferase and beta-galactosidase reporter gene expression.PSV assays were generally more sensitive than VI assays, but there were important differences according to the virus and inhibitor used. For example, for TriMab, the mean IC50 was always lower in PSV than in VI assays. However, with 4E10 or sCD4 some viruses were neutralized with a lower IC50 in VI assays than in the PSV assays. Inter-laboratory concordance was slightly better for PSV than for VI assays with some viruses, but for other viruses agreement between laboratories was limited and depended on both the virus and the neutralizing reagent.The NeutNet project demonstrated clear differences in assay sensitivity that were dependent on both the neutralizing reagent and the virus. No single assay was capable of detecting the entire spectrum of

  17. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    Science.gov (United States)

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  18. A novel reporter system for neutralizing and enhancing antibody assay against dengue virus.

    Science.gov (United States)

    Song, Ke-Yu; Zhao, Hui; Jiang, Zhen-You; Li, Xiao-Feng; Deng, Yong-Qiang; Jiang, Tao; Zhu, Shun-Ya; Shi, Pei-Yong; Zhang, Bo; Zhang, Fu-Chun; Qin, E-De; Qin, Cheng-Feng

    2014-02-18

    Dengue virus (DENV) still poses a global public health threat, and no vaccine or antiviral therapy is currently available. Antibody plays distinct roles in controlling DENV infections. Neutralizing antibody is protective against DENV infection, whereas sub-neutralizing concentration of antibody can increase DENV infection, termed antibody-dependent enhancement (ADE). Plaque-based assay represents the most widely accepted method measuring neutralizing or enhancing antibodies. In this study, a novel reporter virus-based system was developed for measuring neutralization and ADE activity. A stable Renilla luciferase reporter DENV (Luc-DENV) that can produce robust luciferase signals in BHK-21 and K562 cells were used to establish the assay and validated against traditional plaque-based assay. Luciferase value analysis using various known DENV-specific monoclonal antibodies showed good repeatability and a well linear correlation with conventional plaque-based assays. The newly developed assay was finally validated with clinical samples from infected animals and individuals. This reporter virus-based assay for neutralizing and enhancing antibody evaluation is rapid, lower cost, and high throughput, and will be helpful for laboratory detection and epidemiological investigation for DENV antibodies.

  19. Analysis of variola and vaccinia virus neutralization assays for smallpox vaccines.

    Science.gov (United States)

    Hughes, Christine M; Newman, Frances K; Davidson, Whitni B; Olson, Victoria A; Smith, Scott K; Holman, Robert C; Yan, Lihan; Frey, Sharon E; Belshe, Robert B; Karem, Kevin L; Damon, Inger K

    2012-07-01

    Possible smallpox reemergence drives research for third-generation vaccines that effectively neutralize variola virus. A comparison of neutralization assays using different substrates, variola and vaccinia (Dryvax and modified vaccinia Ankara [MVA]), showed significantly different 90% neutralization titers; Dryvax underestimated while MVA overestimated variola neutralization. Third-generation vaccines may rely upon neutralization as a correlate of protection.

  20. Development of a blocking ELISA for detection of serum neutralizing antibodies against newly emerged duck Tembusu virus.

    Directory of Open Access Journals (Sweden)

    Xuesong Li

    Full Text Available BACKGROUND: Since April 2010, domesticated ducks in China have been suffering from an emerging infectious disease characterized by retarded growth, high fever, loss of appetite, decline in egg production, and death. The causative agent was identified as a duck Tembusu virus (DTMUV, a member of the Ntaya virus (NTAV group within the genus Flavivirus, family Flaviviridae. DTMUV is highly contagious and spreads rapidly in many species of ducks. More than 10 million shelducks have been infected and approximately 1 million died in 2010. The disease remains a constant threat to the duck industry; however, it is not known whether DTMUV can infect humans or other mammalians, despite the fact that the virus has spread widely in southeast China, one of the most densely populated areas in the world. The lack of reliable methods to detect the serum antibodies against DTMUV has limited our ability to conduct epidemiological investigations in various natural hosts and to evaluate the efficiency of vaccines to DTMUV. METHODOLOGY/PRINCIPAL FINDINGS: A neutralizing monoclonal antibody (mAb 1F5 binding specifically to the E protein was developed. Based on the mAb, a blocking enzyme-linked immunosorbent assay (ELISA was developed for the detection of neutralizing antibodies against DTMUV. The average value of percent inhibition (PI of 350 duck serum samples obtained from DTMUV-free farms was 1.0% ± 5.8% (mean ± SD. The selected cut-off PI values for negative and positive sera were 12.6% (mean +2SD and 18.4% (mean +3SD, respectively. When compared with a serum neutralizing antibody test (SNT using chicken embryonated eggs, the rate of coincidence was 70.6% between the blocking ELISA and SNT, based on the titration of 20 duck DTMUV-positive serum samples. CONCLUSIONS/SIGNIFICANCE: The blocking ELISA based on a neutralizing mAb allowed rapid, sensitive, and specific detection of neutralization-related antibodies against DTMUV.

  1. Optimizing cationic and neutral lipids for efficient gene delivery at high serum content.

    Science.gov (United States)

    Chan, Chia-Ling; Ewert, Kai K; Majzoub, Ramsey N; Hwu, Yeu-Kuang; Liang, Keng S; Leal, Cecília; Safinya, Cyrus R

    2014-01-01

    Cationic liposome (CL)-DNA complexes are promising gene delivery vectors with potential application in gene therapy. A key challenge in creating CL-DNA complexes for application is that their transfection efficiency (TE) is adversely affected by serum. In particular, little is known about the effects of a high serum content on TE, even though this may provide design guidelines for application in vivo. We prepared CL-DNA complexes in which we varied the neutral lipid [1,2-dioleoyl-sn-glycerophosphatidylcholine, glycerol-monooleate (GMO), cholesterol], the headgroup charge and chemical structure of the cationic lipid, and the ratio of neutral to cationic lipid; we then measured the TE of these complexes as a function of serum content and assessed their cytotoxicity. We tested selected formulations in two human cancer cell lines (M21/melanoma and PC-3/prostate cancer). In the absence of serum, all CL-DNA complexes of custom-synthesized multivalent lipids show high TE. Certain combinations of multivalent lipids and neutral lipids, such as MVL5(5+)/GMO-DNA complexes or complexes based on the dendritic-headgroup lipid TMVLG3(8+) exhibited high TE both in the absence and presence of serum. Although their TE still dropped to a small extent in the presence of serum, it reached or surpassed that of benchmark commercial transfection reagents, particularly at a high serum content. Two-component vectors (one multivalent cationic lipid and one neutral lipid) can rival or surpass benchmark reagents at low and high serum contents (up to 50%, v/v). We propose guidelines for optimizing the serum resistance of CL-DNA complexes based on a given cationic lipid. Copyright © 2014 John Wiley & Sons, Ltd.

  2. Neutralizing antibodies against two HIV-1 strains in consecutively collected serum samples: cross neutralization and association to HIV-1 related disease

    DEFF Research Database (Denmark)

    Arendrup, M; Nielsen, C M; Hansen, J E

    1992-01-01

    97 sera collected during a 10-year period from 10 HIV-1 infected individuals were tested for neutralizing capacity against a virus isolate FICPH-22 obtained from a Danish AIDS patient, and the laboratory strain HTLV-IIIB. Three patterns of serum neutralizing activity were demonstrated: (a) patients...... developing high neutralizing activity against both HIV strains; (b) patients developing high neutralizing activity against the Danish virus isolate; and (c) patients developing only low titers of neutralizing antibodies (NA) against both HIV strains. The HTLV-IIIB strain was less sensitive to serum...... neutralization than the FICPH-22 isolate and the appearance of NA against HTLV-IIIB was typically lacking several years behind that against FICPH-22 indicating a broadening of the NA response over time. No difference in clinical outcome was observed comparing patients reaching high titers of NA and patients...

  3. Determination of antipsychotic drug in human serum by radioreceptor assay

    International Nuclear Information System (INIS)

    Wu Jinchang; Jiang Yimin

    1989-01-01

    Serum antipsychotic drug in 50 psychosis cases were measured by radioreceptor assay (RRA) and the values were compared in parallel with that by radioimmunoassay (RIA). The results showed that the RRA values were lower than the RIA values, but both assays gave significant correlation between the serum drug level and antipsychotic dose

  4. Functional assay of the alternative complement pathway of rat serum

    International Nuclear Information System (INIS)

    Coonrod, J.D.; Jenkins, S.D.

    1979-01-01

    Two functional assays of the alternative pathway of complement activation in rat serum were developed. In the first assay, conditions were established for titration of alternative pathway activity by use of the 50% hemolytic end-point of rabbit red blood cells (RaRBC) in serum treated with ethyleneglycol-bis-(beta-aminoethyl ether)-N, N'-tetraacetic acid (EGTA). The second assay of alternative pathway activity was based on the opsonization of heat-killed radiolabeled pneumococci of serotype 25 (Pn25). Opsonization of Pn25 was shown to proceed entirely via the alternative pathway in rat serum. There was excellent correlation between the results obtained with the RaRBC lysis test and those obtained with the opsonization test. Because of its technical simplicity, the RaRBC lysis test appeared to be the single most useful test of alternative pathway activity in rat serum. (Auth.)

  5. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  6. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    International Nuclear Information System (INIS)

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  7. A Rapid Zika Diagnostic Assay to Measure Neutralizing Antibodies in Patients

    Directory of Open Access Journals (Sweden)

    Chao Shan

    2017-03-01

    Full Text Available The potential association of microcephaly and other congenital abnormalities with Zika virus (ZIKV infection during pregnancy underlines the critical need for a rapid and accurate diagnosis. Due to the short duration of ZIKV viremia in infected patients, a serologic assay that detects antibody responses to viral infection plays an essential role in diagnosing patient specimens. The current serologic diagnosis of ZIKV infection relies heavily on the labor-intensive Plaque Reduction Neutralization Test (PRNT that requires more than one-week turnaround time and represents a major bottleneck for patient diagnosis. To overcome this limitation, we have developed a high-throughput assay for ZIKV and dengue virus (DENV diagnosis that can attain the “gold standard” of the current PRNT assay. The new assay is homogeneous and utilizes luciferase viruses to quantify the neutralizing antibody titers in a 96-well format. Using 91 human specimens, we showed that the reporter diagnostic assay has a higher dynamic range and maintains the relative specificity of the traditional PRNT assay. Besides the improvement of assay throughput, the reporter virus technology has also shortened the turnaround time to less than two days. Collectively, our results suggest that, along with the viral RT-PCR assay, the reporter virus-based serologic assay could be potentially used as the first-line test for clinical diagnosis of ZIKV infection as well as for vaccine clinical trials.

  8. Evaluation of three gentamicin serum assay techniques

    International Nuclear Information System (INIS)

    Matzke, G.R.; Gwizdala, C.; Wery, J.; Ferry, D.; Starnes, R.

    1982-01-01

    This investigation was designed to compare the enzyme-modified immunoassay (Syva--EMIT) with a radioimmunoassay (New England Nuclear--RIA) and the radiometric assay (Johnston--BACTEC) to determine the optimal assay for use in our aminoglycoside dosing service. The serum concentration determinations obtained via the three assay methods were analyzed by linear regression analysis. Significant positive correlations were noted between the three assay techniques (p less than 0.005) during both sample collection phases. The coefficients of determination for EMIT vs BACTEC and RIA vs BACTEC were 0.73 and 0.83 during phase 1, respectively, and 0.65 and 0.68 during phase 2, respectively. The slope of the regression lines also varied markedly during the two phases; 0.49 and 0.42 for EMIT and for RIA vs BACTEC, respectively, during phase 1 compound with 1.12 and 0.77, respectively, during phase 2. The differences noted in these relationships during phase 1 and 2 may be related to the alteration of the pH of the control sera utilized in the BACTEC assay. In contrast, RIA vs EMIT regression analysis indicated that existence of a highly significant relationship (p less than 0.0005 and r2 . 0.90). The EMIT technique was the easiest and most accurate for determination of serum gentamicin concentrations, whereas the BACTEC method was judged unacceptable for clinical use

  9. Automated image-based assay for evaluation of HIV neutralization and cell-to-cell fusion inhibition.

    Science.gov (United States)

    Sheik-Khalil, Enas; Bray, Mark-Anthony; Özkaya Şahin, Gülsen; Scarlatti, Gabriella; Jansson, Marianne; Carpenter, Anne E; Fenyö, Eva Maria

    2014-08-30

    Standardized techniques to detect HIV-neutralizing antibody responses are of great importance in the search for an HIV vaccine. Here, we present a high-throughput, high-content automated plaque reduction (APR) assay based on automated microscopy and image analysis that allows evaluation of neutralization and inhibition of cell-cell fusion within the same assay. Neutralization of virus particles is measured as a reduction in the number of fluorescent plaques, and inhibition of cell-cell fusion as a reduction in plaque area. We found neutralization strength to be a significant factor in the ability of virus to form syncytia. Further, we introduce the inhibitory concentration of plaque area reduction (ICpar) as an additional measure of antiviral activity, i.e. fusion inhibition. We present an automated image based high-throughput, high-content HIV plaque reduction assay. This allows, for the first time, simultaneous evaluation of neutralization and inhibition of cell-cell fusion within the same assay, by quantifying the reduction in number of plaques and mean plaque area, respectively. Inhibition of cell-to-cell fusion requires higher quantities of inhibitory reagent than inhibition of virus neutralization.

  10. Comparison of a neutralization enzyme immunoassay and an enzyme-linked immunosorbent assay for evaluation of immune status of children vaccinated for mumps.

    Science.gov (United States)

    Harmsen, T; Jongerius, M C; van der Zwan, C W; Plantinga, A D; Kraaijeveld, C A; Berbers, G A

    1992-01-01

    A 50% neutralization enzyme immunoassay (N50-EIA) was compared with an indirect enzyme-linked immunosorbent assay (ELISA) for determining mumps virus antibodies in three consecutive serum samples from 138 children vaccinated with a live mumps vaccine at the age (in years) of 1.5. By the N50-EIA, most (132 of 138) preserum samples did not show neutralizing activity. Eight to 12 weeks after vaccination, 17 of the children were still negative, but only 7 remained so after 2.5 years, resulting in a seroconversion rate of 125 of 132 (95%). Over the same period, the neutralization geometric mean titer rose from 3.6 to 9.9. By an indirect ELISA, 128 of 138 preserum samples were found negative. The early and late postvaccination sera of 8 children were ELISA negative, resulting in a seroconversion rate of 120 of 128 (94%). Only two children remained seronegative by both methods. Seven of the late postvaccination serum samples yielded noncorresponding results, reflecting 95% correlation between both methods. Due to cross-reactivity with parainfluenza viruses, the ELISA proved to be less specific, but on the other hand, it showed a greater sensitivity than the N50-EIA. PMID:1500523

  11. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Directory of Open Access Journals (Sweden)

    Leo Heyndrickx

    Full Text Available BACKGROUND: Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s can provide measures of protective immunity. An international collaboration (NeutNet involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs and soluble CD4 (Phase I study. METHODS: In the present study (Phase II, polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (Virus Infectivity Assays, VIA, or Env (gp160-pseudotyped viruses (pseudoviruses, PSV produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP reporter gene expression. FINDINGS: Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014. Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. CONCLUSIONS: Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus

  12. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Science.gov (United States)

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s) can provide measures of protective immunity. An international collaboration (NeutNet) involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs) and soluble CD4 (Phase I study). In the present study (Phase II), polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (Virus Infectivity Assays, VIA), or Env (gp160)-pseudotyped viruses (pseudoviruses, PSV) produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP) reporter gene expression. Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014). Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus. Consistent with the Phase I study, we recommend

  13. New Insights into Butyrylcholinesterase Activity Assay: Serum Dilution Factor as a Crucial Parameter.

    Directory of Open Access Journals (Sweden)

    Joanna Jońca

    Full Text Available Butyrylcholinesterase (BChE activity assay and inhibitor phenotyping can help to identify patients at risk of prolonged paralysis following the administration of neuromuscular blocking agents. The assay plays an important role in clinical chemistry as a good diagnostic marker for intoxication with pesticides and nerve agents. Furthermore, the assay is also commonly used for in vitro characterization of cholinesterases, their toxins and drugs. There is still lack of standardized procedure for measurement of BChE activity and many laboratories use different substrates at various concentrations. The purpose of this study was to validate the BChE activity assay to determine the best dilution of human serum and the most optimal concentration of substrates and inhibitors. Serum BChE activity was measured using modified Ellman's method applicable for a microplate reader. We present our experience and new insights into the protocol for high-throughput routine assays of human plasma cholinesterase activities adapted to a microplate reader. During our routine assays used for the determination of BChE activity, we have observed that serum dilution factor influences the results obtained. We show that a 400-fold dilution of serum and 5mM S-butyrylthiocholine iodide can be successfully used for the accurate measurement of BChE activity in human serum. We also discuss usage of various concentrations of dibucaine and fluoride in BChE phenotyping. This study indicates that some factors of such a multicomponent clinical material like serum can influence kinetic parameters of the BChE. The observed inhibitory effect is dependent on serum dilution factor used in the assay.

  14. International Network for Comparison of HIV Neutralization Assays: The NeutNet Report

    NARCIS (Netherlands)

    Fenyö, Eva Maria; Heath, Alan; Dispinseri, Stefania; Holmes, Harvey; Lusso, Paolo; Zolla-Pazner, Susan; Donners, Helen; Heyndrickx, Leo; Alcami, Jose; Bongertz, Vera; Jassoy, Christian; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Sattentau, Quentin; Schuitemaker, Hanneke; Sutthent, Ruengpung; Wrin, Terri; Scarlatti, Gabriella

    2009-01-01

    BACKGROUND: Neutralizing antibody assessments play a central role in human immunodeficiency virus type-1 (HIV-1) vaccine development but it is unclear which assay, or combination of assays, will provide reliable measures of correlates of protection. To address this, an international collaboration

  15. Comparison of two high-throughput assays for quantification of adenovirus type 5 neutralizing antibodies in a population of donors in China.

    Directory of Open Access Journals (Sweden)

    Qiang Liu

    Full Text Available BACKGROUND: The presence of various levels of Adenovirus serotype 5 neutralizing antibodies (Ad5NAb is thought to contribute to the inconsistent clinical results obtained from vaccination and gene therapy studies. Currently, two platforms based on high-throughput technology are available for Ad5NAb quantification, chemiluminescence- and fluorescence-based assays. The aim of this study was to compare the results of two assays in the seroepidemiology of Ad5NAb in a local population of donors. METHODOLOGY/PRINCIPAL FINDINGS: The fluorescence-based neutralizing antibody detection test (FRNT using recombinant Ad5-EGFP virus and the chemiluminescence-based neutralizing antibody test (CLNT using Ad5-Fluc were developed and standardized for detecting the presence of Ad5NAb in serum samples from the population of donors in Beijing and Anhui provinces, China. First, the overall percentage of people positive for Ad5NAb performed by CLNT was higher than that obtained by FRNT (85.4 vs 69.9%, p<0.001. There was an 84.5% concordance between the two assays for the 206 samples tested (144 positive in both assays and 30 negative in both assays. All 32 discordant sera were CLNT-positive/FRNT-negative and were confirmed positive by western blot. Secondly, for all 144 sera positive by both assays, the two assays showed high correlation (r = 0.94, p<0.001 and close agreement (mean difference: 0.395 log(10, 95% CI: -0.054 log(10 to 0.845 log(10. Finally, it was found by both assays that there was no significant difference observed for titer or prevalence by gender (p = 0.503 vs 0.818, for two assays; however, age range (p = 0.049 vs 0.010 and geographic origin (p = 0.007 vs 0.011 were correlated with Ad5NAb prevalence in northern regions of China. CONCLUSION: The CLNT assay was relatively more simple and had higher sensitivity than the FRNT assay for determining Ad5NAb titers. It is strongly suggested that the CLNT assay be used for future

  16. High-throughput pseudovirion-based neutralization assay for analysis of natural and vaccine-induced antibodies against human papillomaviruses.

    Directory of Open Access Journals (Sweden)

    Peter Sehr

    Full Text Available A highly sensitive, automated, purely add-on, high-throughput pseudovirion-based neutralization assay (HT-PBNA with excellent repeatability and run-to-run reproducibility was developed for human papillomavirus types (HPV 16, 18, 31, 45, 52, 58 and bovine papillomavirus type 1. Preparation of 384 well assay plates with serially diluted sera and the actual cell-based assay are separated in time, therefore batches of up to one hundred assay plates can be processed sequentially. A mean coefficient of variation (CV of 13% was obtained for anti-HPV 16 and HPV 18 titers for a standard serum tested in a total of 58 repeats on individual plates in seven independent runs. Natural antibody response was analyzed in 35 sera from patients with HPV 16 DNA positive cervical intraepithelial neoplasia grade 2+ lesions. The new HT-PBNA is based on Gaussia luciferase with increased sensitivity compared to the previously described manual PBNA (manPBNA based on secreted alkaline phosphatase as reporter. Titers obtained with HT-PBNA were generally higher than titers obtained with the manPBNA. A good linear correlation (R(2 = 0.7 was found between HT-PBNA titers and anti-HPV 16 L1 antibody-levels determined by a Luminex bead-based GST-capture assay for these 35 sera and a Kappa-value of 0.72, with only 3 discordant sera in the low titer range. In addition to natural low titer antibody responses the high sensitivity of the HT-PBNA also allows detection of cross-neutralizing antibodies induced by commercial HPV L1-vaccines and experimental L2-vaccines. When analyzing the WHO international standards for HPV 16 and 18 we determined an analytical sensitivity of 0.864 and 1.105 mIU, respectively.

  17. Measurement of rat serum FSH by radioreceptor assay and comparison with radioimmunoassay

    International Nuclear Information System (INIS)

    Minegishi, Takashi; Igarashi, Masao; Wakabayashi, Katsumi

    1980-01-01

    Follicle stimulating hormone (FSH) in rat serum is successfully measured by a radioreceptor assay system employing PMS-treated immature rat ovary. The non-specific inhibitory effect of serum was partially overcome by the addition of merthiolate to every component, while the residual effect was compensated for by using FSH-free serum which was prepared by passing the pooled female diestrous rat sera through an immunoadsorbent column packed with anti-ovine FSH-coupled Sepharose 4B. The assay system consisted of 100 μl of Tris-MgCl 2 -BSA or standard, 100 μl of FSH-free serum or sample, 100 μl of the receptor preparation and 100 μl of 125 I-FSH. The incubation was carried out for 4 hr at 37 0 C and 500 μl of cold Tris-MgCl 2 -BSA was used for the termination. Serum FSH could be measured within a range of 0.125 - 16 ng NIAMDD rat FSH I-3/tube. The mean within-assay coefficient of variation was 10.5%. The mean between-assay coefficient of variation was 11.0%. The assay values obtained by RRA showed a good correlation to those by RIA under the same physiological states of the animals. The ratio of the assay values, RRA/RIA, was found to change according to the sex and the physiological states, e.g. around 1.3 in normal males and 1.7 in orchiectomized animals and 2.21 in female rats. Serum FSH levels in female rats obtained by RRA and RIA changed almost in parallel until 20:00 (hr) of proestrous day, but after the first surge of serum FSH they were not parallel. These facts seem to indicate possible changes in the affinity of FSH with its receptor according to the state of animals and lead to the problem of the heterogeneity of FSH. (author)

  18. Development and validation of cell-based luciferase reporter gene assays for measuring neutralizing anti-drug antibodies against interferon beta.

    Science.gov (United States)

    Hermanrud, Christina; Ryner, Malin; Luft, Thomas; Jensen, Poul Erik; Ingenhoven, Kathleen; Rat, Dorothea; Deisenhammer, Florian; Sørensen, Per Soelberg; Pallardy, Marc; Sikkema, Dan; Bertotti, Elisa; Kramer, Daniel; Creeke, Paul; Fogdell-Hahn, Anna

    2016-03-01

    Neutralizing anti-drug antibodies (NAbs) against therapeutic interferon beta (IFNβ) in people with multiple sclerosis (MS) are measured with cell-based bioassays. The aim of this study was to redevelop and validate two luciferase reporter-gene bioassays, LUC and iLite, using a cut-point approach to identify NAb positive samples. Such an approach is favored by the pharmaceutical industry and governmental regulatory agencies as it has a clear statistical basis and overcomes the limitations of the current assays based on the Kawade principle. The work was conducted following the latest assay guidelines. The assays were re-developed and validated as part of the "Anti-Biopharmaceutical Immunization: Prediction and analysis of clinical relevance to minimize the risk" (ABIRISK) consortium and involved a joint collaboration between four academic laboratories and two pharmaceutical companies. The LUC assay was validated at Innsbruck Medical University (LUCIMU) and at Rigshospitalet (LUCRH) Copenhagen, and the iLite assay at Karolinska Institutet, Stockholm. For both assays, the optimal serum sample concentration in relation to sensitivity and recovery was 2.5% (v/v) in assay media. A Shapiro-Wilk test indicated a normal distribution for the majority of runs, allowing a parametric approach for cut-point calculation to be used, where NAb positive samples could be identified with 95% confidence. An analysis of means and variances indicated that a floating cut-point should be used for all assays. The assays demonstrated acceptable sensitivity for being cell-based assays, with a confirmed limit of detection in neat serum of 1519 ng/mL for LUCIMU, 814 ng/mL for LUCRH, and 320 ng/mL for iLite. Use of the validated cut-point assay, in comparison with the previously used Kawade method, identified 14% more NAb positive samples. In conclusion, implementation of the cut-point design resulted in increased sensitivity to detect NAbs. However, the clinical significance of these low

  19. Immunoradiometric assay for ferritin in human serum

    International Nuclear Information System (INIS)

    Leyland, M.J.; Ganguli, P.C.; Blower, D.; Delamore, I.W.

    1975-01-01

    A sensitiv specific and precise immunoradiometric assay for ferritin has been developed. Ferritin was measured in the serum of 160 hospital controls, 101 females (118 plus/minus 9 μg/l) and 59 males (189 plus/minus 16 μg/l). This difference was statistically significant. In 28 patients with untreated iron deficiency anemia, serum ferritin concentration (6.1plus/minus 0.7 μg/l) was significantly lower than in the controls, but it was within the normal range in 14 cases of polycythaemia vera treated by repeated phlebotomy. In 4 patients with primary haemachromatosis (2884 plus/minus 56 μg/l), 25 with secondary iron overload states (5702 plus/minus 1235 μg/l) and 8 with haemolytic anaemia (1612 plus/minus 605 μg/l), serum ferritin levels were markedly elevated. In 14 cases of transfusional siderosis there was a highly significant correlation between serum ferritin concentration and units of blood transfused. A circadian rhythmin serum ferritin concentration was observed in 7 healthy subjects. (author)

  20. Neutralization Assay for Zika and Dengue Viruses by Use of Real-Time-PCR-Based Endpoint Assessment.

    Science.gov (United States)

    Wilson, Heather L; Tran, Thomas; Druce, Julian; Dupont-Rouzeyrol, Myrielle; Catton, Michael

    2017-10-01

    The global spread and infective complications of Zika virus (ZKV) and dengue virus (DENV) have made them flaviviruses of public health concern. Serological diagnosis can be challenging due to antibody cross-reactivity, particularly in secondary flavivirus infections or when there is a history of flavivirus vaccination. The virus neutralization assay is considered to be the most specific assay for measurement of anti-flavivirus antibodies. This study describes an assay where the neutralization endpoint is measured by real-time PCR, providing results within 72 h. It demonstrated 100% sensitivity (24/24 ZKV and 15/15 DENV) and 100% specificity (11/11 specimens) when testing well-characterized sera. In addition, the assay was able to determine the correct DENV serotype in 91.7% of cases. The high sensitivity and specificity of the real-time PCR neutralization assay makes it suitable to use as a confirmatory test for sera that are reactive in commercial IgM/IgG enzyme immunoassays. Results are objective and the PCR-based measurement of the neutralization endpoint lends itself to automation so that throughput may be increased in times of high demand. Copyright © 2017 American Society for Microbiology.

  1. Radioenzymatic assay for trimethoprim in very small serum samples.

    OpenAIRE

    Yogev, R; Melick, C; Tan-Pong, L

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved.

  2. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  3. Solid-phase immunoradiometric assay for serum amyloid A protein using magnetisable cellulose particles

    International Nuclear Information System (INIS)

    De Beer, F.C.; Dyck, R.F.; Pepys, M.B.

    1982-01-01

    An immunoradiometric assay for human serum amyloid A protein (SAA) was developed using magnetisable cellulose particles as the solid phase. Rabbit antiserum to SAA was raised by immunization with SAA isolated from acute-phase serum by gel filtration in formic acid. The antiserum was rendered monospecific for SAA by solid-phase immunoabsorption with normal human serum, which contains only traces of SAA, and some was coupled covalently to the cellulose particles. Immunopurified anti-SAA antibodies were isolated from the monospecific anti-SAA serum by binding to, and elution from insolubilized acute-phase serum and were radiolabelled with 125 I. The assay was calibrated with an acute phase serum which contained 6000 times more SAA than normal sera with the lowest detectable level of SAA, and an arbitrary value of 6000 U/l was assigned to this standard. Sera were tested in the native, undenatured state and there was no increase in SAA immunoreactivity following alkali treatment or heating. The assay range was from 1-2000 U/l so that all SAA levels above 6 U/l could be measured on a single (1:6) dilution of serum. The intra- and interassay coefficients of variation were 11.7 and 15.0% respectively. Among 100 healthy normal subjects (50 male, 50 female) the median SAA level was 9 U/l, range <1-100, with 93% below 20 U/l and only 2% below the lower limit of sensitivity of the assay (1 U/l). (Auth.)

  4. Detection of extensive cross-neutralization between pandemic and seasonal A/H1N1 Influenza Viruses using a pseudotype neutralization assay.

    Directory of Open Access Journals (Sweden)

    Béatrice Labrosse

    Full Text Available BACKGROUND: Cross-immunity between seasonal and pandemic A/H1N1 influenza viruses remains uncertain. In particular, the extent that previous infection or vaccination by seasonal A/H1N1 viruses can elicit protective immunity against pandemic A/H1N1 is unclear. METHODOLOGY/PRINCIPAL FINDINGS: Neutralizing titers against seasonal A/H1N1 (A/Brisbane/59/2007 and against pandemic A/H1N1 (A/California/04/2009 were measured using an HIV-1-based pseudovirus neutralization assay. Using this highly sensitive assay, we found that a large fraction of subjects who had never been exposed to pandemic A/H1N1 express high levels of pandemic A/H1N1 neutralizing titers. A significant correlation was seen between neutralization of pandemic A/H1N1 and neutralization of a standard seasonal A/H1N1 strain. Significantly higher pandemic A/H1N1 neutralizing titers were measured in subjects who had received vaccination against seasonal influenza in 2008-2009. Higher pandemic neutralizing titers were also measured in subjects over 60 years of age. CONCLUSIONS/SIGNIFICANCE: Our findings reveal that the extent of protective cross-immunity between seasonal and pandemic A/H1N1 influenza viruses may be more important than previously estimated. This cross-immunity could provide a possible explanation of the relatively mild profile of the recent influenza pandemic.

  5. Automated two-site immunofluorescent assay for the measurement of serum chromogranin A.

    Science.gov (United States)

    Popovici, Théodora; Moreira, Baptiste; Schlageter, Marie-Hélène; Bories, Phuong-Nhi

    2014-01-01

    Chromogranin A (CgA) is the best-characterized biological marker common to neuroendocrine tumours and is therefore recommended for their diagnosis. The measurement of serum CgA is of great importance for reaching an early diagnosis and thus reducing the delay before treatment is instigated. The Kryptor CgA assay is the first fully automated assay available. The aim of this study was to evaluate its analytical performance. The imprecision and linearity of the Kryptor CgA assay were evaluated. This assay was compared with the Cis Bio CgA RIA assay in 78 serum samples. Its clinical utility was assessed in serum from 229 patients. The study performed on imprecision of Kryptor measurements showed intra- and inter-run CVs ≤ 5%. The study of linearity showed a satisfactory recovery rate for CgA concentrations up to 1200 μg/L. The Kryptor and RIA assays agreed well on the basis of the cut-off values provided by the two manufacturers. The Bland and Altman plot of the values obtained (range: 20-5560 μg/L) provided a mean difference of -10.1 μg/L (SD: 116). The clinical sensitivities of Kryptor CgA for diagnosis of pheochromocytoma and paraganglioma (n 20) and gastroenteropancreatic NETs (n 17) were respectively 100 and 94%. The Kryptor assay for CgA shows reliable analytical and clinical characteristics and allows a fast delivery of results. © 2013.

  6. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    International Nuclear Information System (INIS)

    Hovi, T.; Roivainen, M.

    1989-01-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with 51 Cr, [ 3 H]leucine, or, preferentially, with [ 3 H]uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30 degree C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well

  7. Reactivity of human sera in a sensitive, high-throughput pseudovirus-based papillomavirus neutralization assay for HPV16 and HPV18

    International Nuclear Information System (INIS)

    Pastrana, Diana V.; Buck, Christopher B.; Pang, Y.-Y. S.; Thompson, Cynthia D.; Castle, Philip E.; FitzGerald, Peter C.; Krueger Kjaer, Susanne; Lowy, Douglas R.; Schiller, John T.

    2004-01-01

    Sensitive high-throughput neutralization assays, based upon pseudoviruses carrying a secreted alkaline phosphatase (SEAP) reporter gene, were developed and validated for human papillomavirus (HPV)16, HPV18, and bovine papillomavirus 1 (BPV1). SEAP pseudoviruses were produced by transient transfection of codon-modified papillomavirus structural genes into an SV40 T antigen expressing line derived from 293 cells, yielding sufficient pseudovirus from one flask for thousands of titrations. In a 96-well plate format, in this initial characterization, the assay was reproducible and appears to be as sensitive as, but more specific than, a standard papillomavirus-like particle (VLP)-based enzyme-linked immunosorbent assay (ELISA). The neutralization assay detected type-specific HPV16 or HPV18 neutralizing antibodies (titers of 160-10240) in sera of the majority of a group of women infected with the corresponding HPV type, but not in virgin women. Sera from HPV16 VLP vaccinees had high anti-HPV16 neutralizing titers (mean: 45000; range: 5120-163840), but no anti-HPV18 neutralizing activity. The SEAP pseudovirus-based neutralization assay should be a practical method for quantifying potentially protective antibody responses in HPV natural history and prophylactic vaccine studies

  8. Use of 51Cr release to measure the cytotoxic effects of staphylococcal leukocidin and toxin neutralization on bovine leukocytes

    International Nuclear Information System (INIS)

    Loeffler, D.A.; Schat, K.A.; Norcross, N.L.

    1986-01-01

    Leukocidin toxin from Staphylococcus aureus produces specific cytolytic effects on neutrophils and macrophages. The most commonly used method for determination of leukocidin activity is microscopic examination for characteristic morphological changes in toxin-treated cells. The 51 Cr release assay was modified to allow quantitation of the cytolytic effects of leukocidin on bovine peripheral blood neutrophils and lymphocytes. Toxin neutralization by serum and milk samples was quantitated by this method. The neutralizing abilities of the various samples were found to correlate with the levels of immunoglobulin G (IgG1) specific for leukocidin. Undiluted normal serum samples, however, were capable of partially preventing the cytotoxic effects of leukocidin. The assay was shown to be an effective means of quantitating the cytotoxic activity of leukocidin on neutrophils as well as demonstrating neutralization of cytotoxicity by milk and serum samples

  9. Development and characterization of a pre-treatment procedure to eliminate human monoclonal antibody therapeutic drug and matrix interference in cell-based functional neutralizing antibody assays.

    Science.gov (United States)

    Xu, Weifeng; Jiang, Hao; Titsch, Craig; Haulenbeek, Jonathan R; Pillutla, Renuka C; Aubry, Anne-Françoise; DeSilva, Binodh S; Arnold, Mark E; Zeng, Jianing; Dodge, Robert W

    2015-01-01

    Biological therapeutics can induce an undesirable immune response resulting in the formation of anti-drug antibodies (ADA), including neutralizing antibodies (NAbs). Functional (usually cell-based) NAb assays are preferred to determine NAb presence in patient serum, but are often subject to interferences from numerous serum factors, such as growth factors and disease-related cytokines. Many functional cell-based NAb assays are essentially drug concentration assays that imply the presence of NAbs by the detection of small changes in functional drug concentration. Any drug contained in the test sample will increase the total amount of drug in the assay, thus reducing the sensitivity of NAb detection. Biotin-drug Extraction with Acid Dissociation (BEAD) has been successfully applied to extract ADA, thereby removing drug and other interfering factors from human serum samples. However, to date there has been no report to estimate the residual drug level after BEAD treatment when the drug itself is a human monoclonal antibody; mainly due to the limitation of traditional ligand-binding assays. Here we describe a universal BEAD optimization procedure for human monoclonal antibody (mAb) drugs by using a LC-MS/MS method to simultaneously measure drug (a mutant human IgG4), NAb positive control (a mouse IgG), and endogenous human IgGs as an indicator of nonspecific carry-over in the BEAD eluate. This is the first report demonstrating that residual human mAb drug level in clinical sample can be measured after BEAD pre-treatment, which is critical for further BEAD procedure optimization and downstream immunogenicity testing. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. High Concentrations of Measles Neutralizing Antibodies and High-Avidity Measles IgG Accurately Identify Measles Reinfection Cases

    Science.gov (United States)

    Rota, Jennifer S.; Hickman, Carole J.; Mercader, Sara; Redd, Susan; McNall, Rebecca J.; Williams, Nobia; McGrew, Marcia; Walls, M. Laura; Rota, Paul A.; Bellini, William J.

    2016-01-01

    In the United States, approximately 9% of the measles cases reported from 2012 to 2014 occurred in vaccinated individuals. Laboratory confirmation of measles in vaccinated individuals is challenging since IgM assays can give inconclusive results. Although a positive reverse transcription (RT)-PCR assay result from an appropriately timed specimen can provide confirmation, negative results may not rule out a highly suspicious case. Detection of high-avidity measles IgG in serum samples provides laboratory evidence of a past immunologic response to measles from natural infection or immunization. High concentrations of measles neutralizing antibody have been observed by plaque reduction neutralization (PRN) assays among confirmed measles cases with high-avidity IgG, referred to here as reinfection cases (RICs). In this study, we evaluated the utility of measuring levels of measles neutralizing antibody to distinguish RICs from noncases by receiver operating characteristic curve analysis. Single and paired serum samples with high-avidity measles IgG from suspected measles cases submitted to the CDC for routine surveillance were used for the analysis. The RICs were confirmed by a 4-fold rise in PRN titer or by RT-quantitative PCR (RT-qPCR) assay, while the noncases were negative by both assays. Discrimination accuracy was high with serum samples collected ≥3 days after rash onset (area under the curve, 0.953; 95% confidence interval [CI], 0.854 to 0.993). Measles neutralizing antibody concentrations of ≥40,000 mIU/ml identified RICs with 90% sensitivity (95% CI, 74 to 98%) and 100% specificity (95% CI, 82 to 100%). Therefore, when serological or RT-qPCR results are unavailable or inconclusive, suspected measles cases with high-avidity measles IgG can be confirmed as RICs by measles neutralizing antibody concentrations of ≥40,000 mIU/ml. PMID:27335386

  11. Immunoreactive somatomedin A in human serum

    International Nuclear Information System (INIS)

    Hall, K.; Brandt, J.; Enberg, G.; Fryklund, L.

    1979-01-01

    A RIA has been developed for somatomedin A (SM-A) utilizing Sepharose-bound antibodies. This assay, measuring SM-A, the insulin-like growth factors 1 and 2, and somatomedin C, allows determination in serum samples. In comparison with a serum standard, the mean serum levels in patients with acromegaly or GH deficiency and healthy subjects were 8.7 +- 0.7 (n=25), 0.24 +- 0.02 (n=25), and 1.15 +- 0.11 U/ml, respectively. The correlation coefficient between immunoreactive SM-A and SM-A by radioreceptor assay was highly significant (r=0.93), although the potency ratio of SM-A between the two groups of patients was higher in the RIA than in the radioreceptor assay. Gel chromatography revealed that SM-A in acromegalic serum is bound to a carrier protein which is absent in patients with GH deficiency. After gel chromatography at low pH, 90% of applied immunoreactive SM-A was recovered in the low molecular weight fraction and consisted mainly of neutral polypeptides

  12. The peritoneal transport of serum proteins and neutral dextran in CAPD patients

    NARCIS (Netherlands)

    Krediet, R. T.; Koomen, G. C.; Koopman, M. G.; Hoek, F. J.; Struijk, D. G.; Boeschoten, E. W.; Arisz, L.

    1989-01-01

    The peritoneal transport of five serum proteins and intravenously-administered neutral dextran was studied in 13 CAPD patients. In all patients a study was done three hours after the administration of dextran. In nine the study was repeated after 14 hours, and in six also after 38 hours. Using gel

  13. Neutralization potential as an assay of alkalinity of environmental solids

    International Nuclear Information System (INIS)

    Grube, W.E.Jr.; Ammons, J.T.

    1993-01-01

    The method to determine neutralizing equivalence of agricultural limestone has been applied to quantify the amount of bases present in a broad diversity of mineral materials, solid reagents, and products involved in environmental processes. The capacity to neutralize native or imposed acidity must be known in many processes in order to preserve near-neutral material. The standard method for assaying agricultural limestones was adapted to quantify native alkalinity in calcareous rocks exposed by coal surface mining. Data from these analyses continue to provide the surface mining industry and regulating agencies with a measure of the extent to which acidic mine drainage may be neutralized by the natural components of surrounding rock strata and disturbed materials. This approach to determine base content has also been applied to commercially available industrial byproducts added to soils or wastes. Kiln dust, fly ash, sludge, and other additives have been evaluated routinely to measure their alkalinity contribution and also batch-to-batch uniformity. The application of this technique to monitor amounts of reagents added to neutralize acid waste materials by adding alkalis is discussed. Use of this procedure to evaluate different materials is documented with exemplary data. Results of analyses of a broad variety of rock and soil materials, amended soils, soil additives or amendments, industrial waste byproducts, sludge, and treated wastes are presented. Utility of the procedure for routine quality control in soil treatment, amendment uniformity, and product analysis is discussed

  14. Assay of serum ferritin by two different radioimmunometric methods and its clinical significance

    International Nuclear Information System (INIS)

    Kaltwasser, J.P.; Werner, E.; Gesellschaft fuer Strahlen- und Umweltforschung m.b.H., Frankfurt am Main

    1977-01-01

    Serum ferritin was measured by two different radioimmunometric methods a) the Addison assay, b) a commercial radioimmunoassay. Iron storage in the body was determined using 59 Fe. A dose correlation was found between serum ferritin and iron storage in the body. (AJ) [de

  15. Potent neutralizing serum immunoglobulin A (IgA) in human immunodeficiency virus type 2-exposed IgG-seronegative individuals

    DEFF Research Database (Denmark)

    Lizeng, Q; Nilsson, C; Sourial, S

    2004-01-01

    Links Potent neutralizing serum immunoglobulin A (IgA) in human immunodeficiency virus type 2-exposed IgG-seronegative individuals.Lizeng Q, Nilsson C, Sourial S, Andersson S, Larsen O, Aaby P, Ehnlund M, Bjorling E. Research Center, South Hospital, Stockholm, Sweden. The mechanisms behind...... the resistance to human immunodeficiency virus type 2 (HIV-2) infection are still not fully understood. In the present study, we explored the HIV-2-specific humoral serum immunoglobulin A (IgA) immune response in HIV-2-exposed IgG-seronegative (EGSN) individuals. Serum samples from heterosexual EGSN individuals...... and their known HIV-2-infected partners, as well as controls originating from Guinea-Bissau in Africa, were studied. Antibody reactivity to native and recombinant envelope glycoproteins was investigated, and the capacity of purified serum IgA to neutralize HIV-2(SBL6669) was tested. Our results showed that 16...

  16. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein

    International Nuclear Information System (INIS)

    Zhang, Xinsheng; Wallace, Olivia L.; Domi, Arban; Wright, Kevin J.; Driscoll, Jonathan; Anzala, Omu; Sanders, Eduard J.; Kamali, Anatoli; Karita, Etienne; Allen, Susan; Fast, Pat; Gilmour, Jill; Price, Matt A.; Parks, Christopher L.

    2015-01-01

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. - Highlights: • Screened 146 serum samples for measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb). • MV nAb is prevalent in the sera. • CDV neutralizing activity is generally low or absent and when detected it is present in sera with high MV nAb titers. • A neutralization-resistant CDV mutant was isolated using human serum selection. • A mutation was identified in the receptor-binding region of CDV hemagglutinin protein that confers the neutralization resistance

  17. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xinsheng, E-mail: xzhang@iavi.org [AIDS Vaccine Design and Development Laboratory, International AIDS Vaccine Initiative (IAVI), Brooklyn, NY (United States); Molecular and Cellular Biology Program, State University of New York, Brooklyn, NY (United States); Wallace, Olivia L.; Domi, Arban; Wright, Kevin J.; Driscoll, Jonathan [AIDS Vaccine Design and Development Laboratory, International AIDS Vaccine Initiative (IAVI), Brooklyn, NY (United States); Anzala, Omu [Kenya AIDS Vaccine Initiative (KAVI)-Institute of Clinical Research, Nairobi (Kenya); Sanders, Eduard J. [Centre for Geographic Medicine Research, Kenya Medical Research Institute (KEMRI), Kilifi, Kenya & Centre for Clinical Vaccinology and Tropical Medicine, University of Oxford, Headington (United Kingdom); Kamali, Anatoli [MRC/UVRI Uganda Virus Research Unit on AIDS, Masaka and Entebbe (Uganda); Karita, Etienne [Projet San Francisco, Kigali (Rwanda); Allen, Susan [Department of Pathology and Laboratory Medicine, Emory University, Atlanta, GA (United States); Fast, Pat [Department of Medical Affairs, International AIDS Vaccine Initiative, NY, NY (United States); Gilmour, Jill [Human Immunology Laboratory, International AIDS Vaccine Initiative, London (United Kingdom); Price, Matt A. [Department of Medical Affairs, International AIDS Vaccine Initiative, NY, NY (United States); Department of Epidemiology and Biostatistics, University of California at San Francisco, San Francisco, CA (United States); Parks, Christopher L. [AIDS Vaccine Design and Development Laboratory, International AIDS Vaccine Initiative (IAVI), Brooklyn, NY (United States); Molecular and Cellular Biology Program, State University of New York, Brooklyn, NY (United States)

    2015-08-15

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. - Highlights: • Screened 146 serum samples for measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb). • MV nAb is prevalent in the sera. • CDV neutralizing activity is generally low or absent and when detected it is present in sera with high MV nAb titers. • A neutralization-resistant CDV mutant was isolated using human serum selection. • A mutation was identified in the receptor-binding region of CDV hemagglutinin protein that confers the neutralization resistance.

  18. Recent advances in the characterization of HIV-1 neutralization assays for standardized evaluation of the antibody response to infection and vaccination.

    Science.gov (United States)

    Polonis, Victoria R; Brown, Bruce K; Rosa Borges, Andrew; Zolla-Pazner, Susan; Dimitrov, Dimiter S; Zhang, Mei-Yun; Barnett, Susan W; Ruprecht, Ruth M; Scarlatti, Gabriella; Fenyö, Eva-Maria; Montefiori, David C; McCutchan, Francine E; Michael, Nelson L

    2008-06-05

    In AIDS vaccine development the pendulum has swung towards a renewed emphasis on the potential role for neutralizing antibodies in a successful global vaccine. It is recognized that vaccine-induced antibody performance, as assessed in the available neutralization assays, may well serve as a "gatekeeper" for HIV-1 subunit vaccine prioritization and advancement. As a result, development of a standardized platform for reproducible measurement of neutralizing antibodies has received considerable attention. Here we review current advancements in our knowledge of the performance of different types of antibodies in a traditional primary cell neutralization assay and the newer, more standardized TZM-bl reporter cell line assay. In light of recently revealed differences (see accompanying article) in the results obtained in these two neutralization formats, parallel evaluation with both platforms should be contemplated as an interim solution until a better understanding of immune correlates of protection is achieved.

  19. Immune Serum From Sabin Inactivated Poliovirus Vaccine Immunization Neutralizes Multiple Individual Wild and Vaccine-Derived Polioviruses.

    Science.gov (United States)

    Sun, Mingbo; Li, Changgui; Xu, Wenbo; Liao, Guoyang; Li, Rongcheng; Zhou, Jian; Li, Yanping; Cai, Wei; Yan, Dongmei; Che, Yanchun; Ying, Zhifang; Wang, Jianfeng; Yang, Huijuan; Ma, Yan; Ma, Lei; Ji, Guang; Shi, Li; Jiang, Shude; Li, Qihan

    2017-05-15

    A Sabin strain-based inactivated poliomyelitis vaccine (Sabin-IPV) is the rational option for completely eradicating poliovirus transmission. The neutralizing capacity of Sabin-IPV immune serum to different strains of poliovirus is a key indicator of the clinical protective efficacy of this vaccine. Sera collected from 500 infants enrolled in a randomized, blinded, positive control, phase 2 clinical trial were randomly divided into 5 groups: Groups A, B, and C received high, medium, and low doses, respectively, of Sabin-IPV, while groups D and E received trivalent oral polio vaccine and Salk strain-based IPV, respectively, all on the same schedule. Immune sera were collected after the third dose of primary immunization, and tested in cross-neutralization assays against 19 poliovirus strains of all 3 types. All immune sera from all 5 groups interacted with the 19 poliovirus strains with various titers and in a dose-dependent manner. One type 2 immunodeficiency-associated vaccine-derived poliovirus strain was not recognized by these immune sera. Sabin-IPV vaccine can induce protective antibodies against currently circulating and reference wild poliovirus strains and most vaccine-derived poliovirus strains, with rare exceptions. NCT01056705. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  20. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    International Nuclear Information System (INIS)

    Ahlstedt, S.; Rylander, H.

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, 125 I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not. (author)

  1. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstedt, S; Rylander, H [Goeteborg Univ. (Sweden)

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, /sup 125/I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not.

  2. Management strategy in pregnancies with elevated second-trimester maternal serum alpha-fetoprotein based on a second assay.

    Science.gov (United States)

    Spaggiari, Emmanuel; Ruas, Marie; Dreux, Sophie; Valat, Anne-Sylvie; Czerkiewicz, Isabelle; Guimiot, Fabien; Schmitz, Thomas; Delezoide, Anne-Lise; Muller, Françoise

    2013-04-01

    To assess maternal-fetal outcomes in pregnancies associated with persistently elevated second-trimester maternal serum alpha-fetoprotein. A retrospective cohort study in 658 patients with maternal serum alpha-fetoprotein ≥2.5 multiple of median, performed at routine Down syndrome screening. Maternal serum alpha-fetoprotein was assayed a second time in 341 of them. Outcomes were recorded in all cases. The group with unexplained maternal serum alpha-fetoprotein persistently ≥2.5 multiple of median was associated with more pregnancy complications 37 of 92 (40.2%) as fetal death, preeclampsia, intrauterine growth restriction, and congenital nephrotic syndrome, compared with the group with maternal serum alpha-fetoprotein that returned to a normal level 37 of 226 (16.4%) (P alpha-fetoprotein returns to a normal level on a second assay, the risk of adverse outcome significantly decreases, but these pregnancies are still at risk of complications and therefore need close surveillance. Repeat maternal serum alpha-fetoprotein assay allows identification of patients who should be offered amniocentesis to evaluate the risk of nephrotic syndrome and epidermolysis bullosa. Alpha-fetoprotein should be monitored in pregnancies associated with unexplained high maternal serum alpha-fetoprotein. A management strategy based on ultrasound examination, second maternal serum alpha-fetoprotein assay and amniocentesis is proposed to improve prenatal counseling and management of such pregnancies. However, a prospective study remains necessary to evaluate it. Copyright © 2013 Mosby, Inc. All rights reserved.

  3. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  4. Standardization of Neisseria meningitidis Serogroup B Colorimetric Serum Bactericida Assay

    Science.gov (United States)

    Rodríguez, Tamara; Lastre, Miriam; Cedré, Barbara; Campo, Judith del; Bracho, Gustavo; Zayas, Caridad; Taboada, Carlos; Díaz, Miriam; Sierra, Gustavo; Pérez, Oliver

    2002-01-01

    The correlate of protection for serogroup B meningococci is not currently known, but for serogroup C it is believed to be the serum bactericidal assay (SBA). The current SBAs are labor intensive and the variations in protocols among different laboratories make interpretation of results difficult. A colorimetric SBA (cSBA), based on the ability of Neisseria meningitidis serogroup B to consume glucose, leading to acid production, was standardized by using group B strain Cu385-83 as the target. The cSBA results were compared to those obtained for a traditional colony-counting microassay (mSBA). Glucose and bromocresol purple pH indicator were added to the medium in order to estimate growth of cSBA target cell survivors through color change. Different variants of the assay parameters were optimized: growth of target cells (Mueller Hinton agar plates), target cell number (100 CFU/per well), and human complement source used at a final concentration of 25%. After the optimization, three other group B strains (H44/76, 490/91, and 511/91) were used as targets for the cSBA. The selection of the assay parameters and the standardization of cSBA were done with 13 sera from vaccinated volunteers. The titers were determined as the higher serum dilution that totally inhibited the bacterial growth marked by the color invariability of the pH indicator. This was detected visually as well as spectrophotometrically and was closely related to a significant difference in the growth of target cell survivors determined using Student’s t test. Intralaboratory reproducibility was ±1 dilution. The correlation between bactericidal median titers and specific immunoglobulin G serum concentration by enzyme immunoassay was high (r = 0.910, P < 0.01). The bactericidal titers generated by the cSBA and the mSBA were nearly identical, and there was a high correlation between the two assays (r = 0.974, P < 0.01). The standardized cSBA allows easy, fast, and efficient evaluation of samples. PMID

  5. Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood

    International Nuclear Information System (INIS)

    McGown, E.L.; Lewis, C.M.; Dong, M.H.; Sauberlich, H.E.

    1978-01-01

    Results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] were compared with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested on whole-blood samples; both yielded values significantly higher than those by microbiological assay. The frequency distributions of erythrocyte folate data differed strikingly between the two kits; the NEN method yielded a much narrower range of normal values than did either the Bio-Rad or the microbiological assay. Radioassay kits appear to be suitable diagnostic agents for serum folate, if the behavior of a particular kit is investigated thoroughly before its routine use. However, the diagnostic value of radioassays of erythrocyte folate needs to be validated

  6. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    Energy Technology Data Exchange (ETDEWEB)

    Pals, G; Meuwissen, S G.M.; Frants, R R; Kostense, P J; Eriksson, A W; Raesaenen, V

    1987-02-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 ..mu..g/l and r=0.971 in the range 0-100 ..mu..g/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum.

  7. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    International Nuclear Information System (INIS)

    Pals, Gerard; Meuwissen, S.G.M.; Frants, R.R.; Kostense, P.J.; Eriksson, A.W.; Raesaenen, Vesa

    1987-01-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 μg/l and r=0.971 in the range 0-100 μg/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum. (author)

  8. [Evaluation of serum PIVKA-II by Lumipulse PrestoII assay].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Kani, Satomi; Goto, Takaaki; Takasaka, Yoshimitsu; Matsuura, Kentaro; Sugauchi, Fuminaka; Moriyama, Kazushige; Murakami, Hiroshi; Kitajima, Sachiko; Mizokami, Masashi

    2009-03-01

    Measurements of serum concentrations of Des-gamma-carboxy Prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, in Lumipulsef assay, it was reported that antibodies against alkaline phosphatase (ALP) derived from anti bleeding sheets led false high values of PIVKA-II in the patients with HCC resection. To improve the previous issue, newly developed Lumipulse PrestoII assay was examined. (1) The assay was reliable and positively correlated with the previous assays (Lumipulse f and Picolumi, R = 0.997 and 0.994 (n=115), respectively). (2) Eleven cases, which had false high values of PIVKA-II by the Lumipulsef assay, were examined by the PrestoII assay with excess of inactive ALP. The false high values of 10 cases were improved, but only one was still high. False reactivity of this case was stronger than other cases, more effective adsorption was required. (3) Comparing the absorbent activity of inactive ALP among 6 different kinds, we found inactive ALP with much higher adsorbent activity. When this inactive ALP was applied to assay, false high values of PIVKA-II were improved in all 11 cases. In conclusion, the PrestoII assay, which applies the inactive ALP with high activity, is reliable and useful for clinical screening.

  9. Neutral Red versus MTT assay of cell viability in the presence of copper compounds.

    Science.gov (United States)

    Gomez Perez, Mariela; Fourcade, Lyvia; Mateescu, Mircea Alexandru; Paquin, Joanne

    2017-10-15

    Copper is essential for numerous physiological functions, and copper compounds may display therapeutic as well as cytotoxic effects. The MTT (3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide) assay is a standard test largely used in cytotoxicity studies. This report shows that low micromolar levels of copper compounds such as Cu(II)Urea 2 , Cu(II)Ser 2 and CuCl 2 can interfere with the MTT assay making improper the detection of formazan product of MTT reduction. Comparatively, the Neutral Red assay appears to be sensitive and showing no interference with these compounds. The lactate dehydrogenase alternative assay cannot be used because of inhibitory effect of these copper compounds on the enzyme activity. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Caldin, Marco; Tecles, Fernando; Ceron, Jose J

    2013-09-01

    Measurements of immunoglobulins (Igs) in companion animals can be useful to detect deficiencies of the humoral immune system, that can be associated with opportunistic or chronic infections, or other immune-mediated disorders including B-cell neoplasms. The purpose of this study was to evaluate commercially available automated immunoturbidimetric assays designed for human IgG, M, and A measurements in canine and feline serum using species-specific calibrators. Canine and feline serum samples with different IgG, M, and A concentrations were used for the analytical validation of the assays. Intra- and inter-assay precision, linearity under dilution, spiking recovery, and limit of detection were determined. In addition, effects of lipemia, hemolysis, and bilirubinemia were evaluated. Finally, Ig concentrations were determined in small groups of diseased dogs and cats, and compared with healthy groups. Spiking recovery and linearity under dilution tests showed that the assays measured Igs in canine and feline serum samples precisely and accurately. Intra- and inter-assay imprecisions were lower than 15% in all cases. Significantly higher IgG, IgM, and IgA levels were observed in dogs with leishmaniasis, while dogs with pyometra showed a statistically significant increase in IgM and IgA concentrations in comparison with healthy dogs. Significantly higher IgG and IgM levels were observed in FIV-infected cats compared with healthy ones. The automated human Ig assays showed adequate precision and accuracy with serum samples from dogs and cats. Also, they were able to discriminate different concentrations of Igs in healthy and diseased animals. © 2013 American Society for Veterinary Clinical Pathology.

  11. Comparative evaluation of various solid phases for the development of coated tube assays for the estimation of progesterone in human serum, bovine serum and bovine milk

    International Nuclear Information System (INIS)

    Karir, Tarveen; Samuel, Grace; Sivaprasad, N.; Venkatesh, Meera

    2009-01-01

    Immobilization of progesterone antibody using three polystyrene surfaces and two progesterone radiotracers for use in the development of a coated tube assay for the evaluation of progesterone levels in human serum, bovine serum and bovine milk was studied. The selection of the solid phase and the tracers were based on the maximum binding, non-specific binding, sensitivity and percentage recovery. Amongst the polystyrene tubes studied, streptavidin coated tubes showed the acceptable assay features such as low non-specific binding (0.5-1.0%), adequate sensitivity (0.13-0.16 ng/ml) and recovery (85-115%) for all the three sample matrices, human serum, bovine serum and bovine milk.

  12. A pseudovirus-based hemagglutination-inhibition assay as a rapid, highly sensitive, and specific assay for detecting avian influenza A (H7N9 antibodies

    Directory of Open Access Journals (Sweden)

    Anli Zhang

    2015-06-01

    Full Text Available Background Increased surveillance of avian-origin influenza A (H7N9 virus infection is critical to assess the risk of new outbreaks in China. A high-throughput assay with a good safety profile, sensitivity, and specificity is urgently needed. Methods We used a hemagglutination-inhibition (HI assay based on an H7N9-enveloped pseudovirus to assess serum neutralization antibodies level in 40 H7N9 positive sera and 40 H7N9 negative sera and compared the efficacy of the assay with traditional HI test and micro-neutralization (MN test. Results Spearman’s rank correlation coefficient analysis showed pseudovirus HI (PHI titers correlated well with both HI titers and MN titers. Receiver operating characteristic (ROC curves test revealed using a PHI cut-off titer of 10, the sensitivity and specificity reached 1.0. Conclusions PHI can be used in H7N9-related serological studies. This assay is high-throughput, very sensitive and specific, and cost effective.

  13. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  14. The potential value of the neutral comet assay and the expression of genes associated with DNA damage in assessing the radiosensitivity of tumor cells.

    Science.gov (United States)

    Jayakumar, Sundarraj; Bhilwade, Hari N; Pandey, Badri N; Sandur, Santosh K; Chaubey, Ramesh C

    2012-10-09

    The assessment of tumor radiosensitivity would be particularly useful in optimizing the radiation dose during radiotherapy. Therefore, the degree of correlation between radiation-induced DNA damage, as measured by the alkaline and the neutral comet assays, and the clonogenic survival of different human tumor cells was studied. Further, tumor radiosensitivity was compared with the expression of genes associated with the cellular response to radiation damage. Five different human tumor cell lines were chosen and the radiosensitivity of these cells was established by clonogenic assay. Alkaline and neutral comet assays were performed in γ-irradiated cells (2-8Gy; either acute or fractionated). Quantitative PCR was performed to evaluate the expression of DNA damage response genes in control and irradiated cells. The relative radiosensitivity of the cell lines assessed by the extent of DNA damage (neutral comet assay) immediately after irradiation (4Gy or 6Gy) was in agreement with radiosensitivity pattern obtained by the clonogenic assay. The survival fraction of irradiated cells showed a better correlation with the magnitude of DNA damage measured by the neutral comet assay (r=-0.9; Pcomet assay (r=-0.73; Pcomet assay was better than alkaline comet assay for assessment of radiosensitivities of tumor cells after acute or fractionated doses of irradiation. © 2012 Elsevier B.V. All rights reserved.

  15. Cupric ion reducing antioxidant capacity assay for antioxidants in human serum and for hydroxyl radical scavengers.

    Science.gov (United States)

    Apak, Reşat; Güçlü, Kubilay; Ozyürek, Mustafa; Bektaşoğlu, Burcu; Bener, Mustafa

    2010-01-01

    Tests measuring the combined antioxidant effect of the nonenzymatic defenses in biological fluids may be useful in providing an index of the organism's capability to counteract reactive species known as pro-oxidants, resist oxidative damage, and combat oxidative stress-related diseases. The selected chromogenic redox reagent for the assay of human serum should be easily accessible, stable, selective, and respond to all types of biologically important antioxidants such as ascorbic acid, alpha-tocopherol, beta-carotene, reduced glutathione (GSH), uric acid, and bilirubin, regardless of chemical type or hydrophilicity. Our recently developed cupric reducing antioxidant capacity (CUPRAC) spectrophotometric method for a number of polyphenols and flavonoids using the copper(II)-neocuproine reagent in ammonium acetate buffer is now applied to a complete series of plasma antioxidants for the assay of total antioxidant capacity of serum, and the resulting absorbance at 450 nm is recorded either directly (e.g., for ascorbic acid, alpha-tocopherol, and glutathione) or after incubation at 50 degrees C for 20 min (e.g., for uric acid, bilirubin, and albumin), quantitation being made by means of a calibration curve. The lipophilic antioxidants, alpha-tocopherol and beta-carotene, are assayed in dichloromethane. Lipophilic antioxidants of serum are extracted with n-hexane from an ethanolic solution of serum subjected to centrifugation. Hydrophilic antioxidants of serum are assayed in the centrifugate after perchloric acid precipitation of proteins. The CUPRAC molar absorptivities, linear ranges, and TEAC (trolox equivalent antioxidant capacity) coefficients of the serum antioxidants are established, and the results are evaluated in comparison with the findings of the ABTS/TEAC reference method. The intra- and inter-assay coefficients of variation (CVs) are 0.7 and 1.5%, respectively, for serum. The CUPRAC assay proved to be efficient for glutathione and thiol-type antioxidants

  16. A novel immunological assay for hepcidin quantification in human serum.

    Directory of Open Access Journals (Sweden)

    Vasiliki Koliaraki

    Full Text Available BACKGROUND: Hepcidin is a 25-aminoacid cysteine-rich iron regulating peptide. Increased hepcidin concentrations lead to iron sequestration in macrophages, contributing to the pathogenesis of anaemia of chronic disease whereas decreased hepcidin is observed in iron deficiency and primary iron overload diseases such as hereditary hemochromatosis. Hepcidin quantification in human blood or urine may provide further insights for the pathogenesis of disorders of iron homeostasis and might prove a valuable tool for clinicians for the differential diagnosis of anaemia. This study describes a specific and non-operator demanding immunoassay for hepcidin quantification in human sera. METHODS AND FINDINGS: An ELISA assay was developed for measuring hepcidin serum concentration using a recombinant hepcidin25-His peptide and a polyclonal antibody against this peptide, which was able to identify native hepcidin. The ELISA assay had a detection range of 10-1500 microg/L and a detection limit of 5.4 microg/L. The intra- and interassay coefficients of variance ranged from 8-15% and 5-16%, respectively. Mean linearity and recovery were 101% and 107%, respectively. Mean hepcidin levels were significantly lower in 7 patients with juvenile hemochromatosis (12.8 microg/L and 10 patients with iron deficiency anemia (15.7 microg/L and higher in 7 patients with Hodgkin lymphoma (116.7 microg/L compared to 32 age-matched healthy controls (42.7 microg/L. CONCLUSIONS: We describe a new simple ELISA assay for measuring hepcidin in human serum with sufficient accuracy and reproducibility.

  17. Development and evaluation of a blocking enzyme-linked immunosorbent assay and virus neutralization assay to detect antibodies to viral hemorrhagic septicemia virus

    Science.gov (United States)

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas M.; Toohey-Kurth, Kathy

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV.

  18. Development of in vitro and in vivo rabies virus neutralization assays based on a high-titer pseudovirus system

    Science.gov (United States)

    Nie, Jianhui; Wu, Xiaohong; Ma, Jian; Cao, Shouchun; Huang, Weijin; Liu, Qiang; Li, Xuguang; Li, Yuhua; Wang, Youchun

    2017-01-01

    Pseudoviruses are useful virological tools because of their safety and versatility; however the low titer of these viruses substantially limits their wider applications. We developed a highly efficient pseudovirus production system capable of yielding 100 times more rabies pseudovirus than the traditional method. Employing the high-titer pseudoviruses, we have developed robust in vitro and in vivo neutralization assays for the evaluation of rabies vaccine, which traditionally relies on live-virus based assays. Compared with current rapid fluorescent focus inhibition test (RFFIT), our in vitro pseudovirus-based neutralization assay (PBNA) is much less labor-intensive while demonstrating better reproducibility. Moreover, the in vivo PBNA assay was also found to be superior to the live virus based assay. Following intravenous administration, the pseudovirus effectively infected the mice, with dynamic viral distributions being sequentially observed in spleen, liver and brain. Furthermore, data from in vivo PBNA showed great agreement with those generated from the live virus model but with the experimental time significantly reduced from 2 weeks to 3 days. Taken together, the effective pseudovirus production system facilitated the development of novel PBNA assays which could replace live virus-based traditional assays due to its safety, rapidity, reproducibility and high throughput capacity. PMID:28218278

  19. Genotoxicity testing: Comparison of the γH2AX focus assay with the alkaline and neutral comet assays.

    Science.gov (United States)

    Nikolova, Teodora; Marini, Federico; Kaina, Bernd

    2017-10-01

    Genotoxicity testing relies on the quantitative measurement of adverse effects, such as chromosome aberrations, micronuclei, and mutations, resulting from primary DNA damage. Ideally, assays will detect DNA damage and cellular responses with high sensitivity, reliability, and throughput. Several novel genotoxicity assays may fulfill these requirements, including the comet assay and the more recently developed γH2AX assay. Although they are thought to be specific for genotoxicants, a systematic comparison of the assays has not yet been undertaken. In the present study, we compare the γH2AX focus assay with the alkaline and neutral versions of the comet assay, as to their sensitivities and limitations for detection of genetic damage. We investigated the dose-response relationships of γH2AX foci and comet tail intensities at various times following treatment with four prototypical genotoxicants, methyl methanesulfonate (MMS), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), mitomycin C, and hydrogen peroxide (H 2 O 2 ) and we tested whether there is a correlation between the endpoints, i.e., alkali-labile sites and DNA strand breaks on the one hand and the cell's response to DNA double-strand breaks and blocked replication forks on the other. Induction of γH2AX foci gave a linear dose response and all agents tested were positive in the assay. The increase in comet tail intensity was also a function of dose; however, mitomycin C was almost completely ineffective in the comet assay, and the doses needed to achieve a significant effect were somewhat higher for some treatments in the comet assay than in the γH2AX foci assay, which was confirmed by threshold analysis. There was high correlation between tail intensity and γH2AX foci for MMS and H 2 O 2 , less for MNNG, and none for mitomycin C. From this we infer that the γH2AX foci assay is more reliable, sensitive, and robust than the comet assay for detecting genotoxicant-induced DNA damage. Copyright © 2017 Elsevier

  20. Establishment and clinical application of immunoradiometric assay for human growth hormone in serum

    International Nuclear Information System (INIS)

    Ji Jinfeng; Wu Congyuan; Niu Zhanpo; Zhang Kui; Song Ailing; Deng Jieying; Shi Mifan

    1992-01-01

    An immunoradiometric assay (IRMA) for human growth hormone (hGH) in serum is developed based on two high specific monoclonal antibodies against hGh. It can specifically detect the levels of serum bioactive hGh and had no cross-reaction with human prolactin (hPRL) and hGh oligmeric forms. The sensitivity was 0.2 ng/ml and the recovery for different concentrations of hGh was 92.0% ∼ 103.2%. The coefficients of variation for intra and inter-assay were<9.1% and <14.2%, respectively. Integral analysis of the results of RIA and IRMA with the patients' clinical manifestations revealed that hGh IRMA is better than hGh RIA in reflecting the clinical states of different acromegalic patients

  1. Dengue-Immune Humans Have Higher Levels of Complement-Independent Enhancing Antibody than Complement-Dependent Neutralizing Antibody.

    Science.gov (United States)

    Yamanaka, Atsushi; Konishi, Eiji

    2017-09-25

    Dengue is the most important arboviral disease worldwide. We previously reported that most inhabitants of dengue-endemic countries who are naturally immune to the disease have infection-enhancing antibodies whose in vitro activity does not decrease in the presence of complement (complement-independent enhancing antibodies, or CiEAb). Here, we compared levels of CiEAb and complement-dependent neutralizing antibodies (CdNAb) in dengue-immune humans. A typical antibody dose-response pattern obtained in our assay system to measure the balance between neutralizing and enhancing antibodies showed both neutralizing and enhancing activities depending on serum dilution factor. The addition of complement to the assay system increased the activity of neutralizing antibodies at lower dilutions, indicating the presence of CdNAb. In contrast, similar dose-response curves were obtained with and without complement at higher dilutions, indicating higher levels of CiEAb than CdNAb. For experimental support for the higher CiEAb levels, a cocktail of mouse monoclonal antibodies against dengue virus type 1 was prepared. The antibody dose-response curves obtained in this assay, with or without complement, were similar to those obtained with human serum samples when a high proportion of D1-V-3H12 (an antibody exhibiting only enhancing activity and thus a model for CiEAb) was used in the cocktail. This study revealed higher-level induction of CiEAb than CdNAb in humans naturally infected with dengue viruses.

  2. Prediction of Protection against Asian Enterovirus 71 Outbreak Strains by Cross-neutralizing Capacity of Serum from Dutch Donors, The Netherlands

    Science.gov (United States)

    Koen, Gerrit; van Eijk, Hetty; Koekkoek, Sylvie M.; de Jong, Menno D.; Wolthers, Katja C.

    2016-01-01

    Outbreaks of human enterovirus 71 (EV-71) in Asia are related to high illness and death rates among children. To gain insight into the potential threat for the population of Europe, we determined the neutralizing activity in intravenous immunoglobulin (IVIg) batches and individual serum samples from donors in the Netherlands against EV-71 strains isolated in Europe and in Asia. All IVIg batches and 41%, 79%, and 65% of serum samples from children ≤5 years of age, women of childbearing age, and HIV-positive men, respectively, showed high neutralizing activity against a Dutch C1 strain, confirming widespread circulation of EV-71 in the Netherlands. Asian B3–4 and C4 strains were efficiently cross-neutralized, predicting possible protection against extensive circulation and associated outbreaks of those types in Europe. However, C2 and C5 strains that had few mutations in the capsid region consistently escaped neutralization, emphasizing the importance of monitoring antigenic diversity among circulating EV-71 strains. PMID:27533024

  3. Prediction of Protection against Asian Enterovirus 71 Outbreak Strains by Cross-neutralizing Capacity of Serum from Dutch Donors, The Netherlands.

    Science.gov (United States)

    van der Sanden, Sabine M G; Koen, Gerrit; van Eijk, Hetty; Koekkoek, Sylvie M; de Jong, Menno D; Wolthers, Katja C

    2016-09-01

    Outbreaks of human enterovirus 71 (EV-71) in Asia are related to high illness and death rates among children. To gain insight into the potential threat for the population of Europe, we determined the neutralizing activity in intravenous immunoglobulin (IVIg) batches and individual serum samples from donors in the Netherlands against EV-71 strains isolated in Europe and in Asia. All IVIg batches and 41%, 79%, and 65% of serum samples from children ≤5 years of age, women of childbearing age, and HIV-positive men, respectively, showed high neutralizing activity against a Dutch C1 strain, confirming widespread circulation of EV-71 in the Netherlands. Asian B3-4 and C4 strains were efficiently cross-neutralized, predicting possible protection against extensive circulation and associated outbreaks of those types in Europe. However, C2 and C5 strains that had few mutations in the capsid region consistently escaped neutralization, emphasizing the importance of monitoring antigenic diversity among circulating EV-71 strains.

  4. Measurement of neutralizing serum antibodies of patients vaccinated with human papillomavirus L1 or L2-based immunogens using furin-cleaved HPV Pseudovirions.

    Directory of Open Access Journals (Sweden)

    Joshua W Wang

    Full Text Available Antibodies specific for neutralizing epitopes in either Human papillomavirus (HPV capsid protein L1 or L2 can mediate protection from viral challenge and thus their accurate and sensitive measurement at high throughput is likely informative for monitoring response to prophylactic vaccination. Here we compare measurement of L1 and L2-specific neutralizing antibodies in human sera using the standard Pseudovirion-Based Neutralization Assay (L1-PBNA with the newer Furin-Cleaved Pseudovirion-Based Neutralization Assay (FC-PBNA, a modification of the L1-PBNA intended to improve sensitivity towards L2-specific neutralizing antibodies without compromising assay of L1-specific responses. For detection of L1-specific neutralizing antibodies in human sera, the FC- PBNA and L1-PBNA assays showed similar sensitivity and a high level of correlation using WHO standard sera (n = 2, and sera from patients vaccinated with Gardasil (n = 30 or an experimental human papillomavirus type 16 (HPV16 L1 VLP vaccine (n = 70. The detection of L1-specific cross-neutralizing antibodies in these sera using pseudovirions of types phylogenetically-related to those targeted by the L1 virus-like particle (VLP vaccines was also consistent between the two assays. However, for sera from patients (n = 17 vaccinated with an L2-based immunogen (TA-CIN, the FC-PBNA was more sensitive than the L1-PBNA in detecting L2-specific neutralizing antibodies. Further, the neutralizing antibody titers measured with the FC-PBNA correlated with those determined with the L2-PBNA, another modification of the L1-PBNA that spacio-temporally separates primary and secondary receptor engagement, as well as the protective titers measured using passive transfer studies in the murine genital-challenge model. In sum, the FC-PBNA provided sensitive measurement for both L1 VLP and L2-specific neutralizing antibody in human sera. Vaccination with TA-CIN elicits weak cross-protective antibody in a

  5. Tear and serum IgE concentrations by Tandem-R IgE immunoradiometric assay in allergic patients

    International Nuclear Information System (INIS)

    Insler, M.S.; Lim, J.M.; Queng, J.T.; Wanissorn, C.; McGovern, J.P.

    1987-01-01

    The authors studied a population of 39 allergic and 15 nonallergic patients, and determined their tear and serum IgE concentrations. Samples of tear and serum were tested for IgE by the Tandem-R immunoradiometric assay, which uses monoclonal antibody to produce a specific assay for IgE. The serum IgE levels in the study group showed a range from 23,280 to 16 IU/ml compared with controls of 72 to 2 IU/ml. Tear IgE in the study group varied from 159 IU/ml to less than 1 IU/ml compared with controls of 8 IU/ml to less than 1 IU/ml. A statistically significant correlation between tear and serum IgE exists in the allergic patients with eye symptoms. It also exists when serum IgE was greater than 100 IU/ml, the tear IgE greater than 4 IU/ml, or when both the serum IgE was greater than 100 IU/ml and the tear IgE greater than 4 IU/ml

  6. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  7. 9G4 autoreactivity is increased in HIV-infected patients and correlates with HIV broadly neutralizing serum activity.

    Directory of Open Access Journals (Sweden)

    James J Kobie

    Full Text Available The induction of a broadly neutralizing antibody (BNAb response against HIV-1 would be a desirable feature of a protective vaccine. Vaccine strategies thus far have failed to elicit broadly neutralizing antibody responses; however a minority of HIV-infected patients do develop circulating BNAbs, from which several potent broadly neutralizing monoclonal antibodies (mAbs have been isolated. The findings that several BNmAbs exhibit autoreactivity and that autoreactive serum antibodies are observed in some HIV patients have advanced the possibility that enforcement of self-tolerance may contribute to the rarity of BNAbs. To examine the possible breakdown of tolerance in HIV patients, we utilized the 9G4 anti-idiotype antibody system, enabling resolution of both autoreactive VH4-34 gene-expressing B cells and serum antibodies. Compared with healthy controls, HIV patients had significantly elevated 9G4+ serum IgG antibody concentrations and frequencies of 9G4+ B cells, a finding characteristic of systemic lupus erythematosus (SLE patients, both of which positively correlated with HIV viral load. Compared to the global 9G4-IgD--memory B cell population, the 9G4+IgD--memory fraction in HIV patients was dominated by isotype switched IgG+ B cells, but had a more prominent bias toward "IgM only" memory. HIV envelope reactivity was observed both in the 9G4+ serum antibody and 9G4+ B cell population. 9G4+ IgG serum antibody levels positively correlated (r = 0.403, p = 0.0019 with the serum HIV BNAbs. Interestingly, other serum autoantibodies commonly found in SLE (anti-dsDNA, ANA, anti-CL did not correlate with serum HIV BNAbs. 9G4-associated autoreactivity is preferentially expanded in chronic HIV infection as compared to other SLE autoreactivities. Therefore, the 9G4 system provides an effective tool to examine autoreactivity in HIV patients. Our results suggest that the development of HIV BNAbs is not merely a consequence of a general breakdown in

  8. Studies on the 2-site immunoradiometric assay of serum ferritin and its applications for diagnosis of iron deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, J.; Niitsu, Y. (Sapporo Medical Coll. (Japan). Cancer Research Inst.)

    1980-10-01

    The 2-site immunoradiometric assay using paper discs as a solid phase material was established for the measurement of serum ferritin. The standard curve was found the range from 0.5ng -- 500ng ferritin per ml and the sensitivity limit of the assay was 0.1ng ferritin per ml. The clinical value of serum ferritin assay was then investigated for diagnosis of iron deficiency. The mean serum ferritin concentrations of normal subjects were greater for males (119.8+-55.5ng/ml) than for females (56.5+-55.5ng/ml) although this sex difference was not distinct beyond the age of 45. All 15 patients with iron deficient anemia had serum ferritin concentrations below the normal range, whereas in other anemias including anemia associated with chronic inflammation, pernicious anemia, aplastic anemia, serum ferritin concentrations were normal or elevated. In 116 apparently normal subjects, 13.8% of total females had abnormally low serum ferritin concentrations with normal hemoglobin levels. The cytochrome c oxidase activity of peripheral leucocytes from those subjects were generally depleted. Most of them frequently suffered from easy fatigability, weakness, and dizziness and these complications were clearly relieved by the administration of iron. Measurement of serum ferritin was found to be quite useful for diagnosis and assessment of iron deficient states.

  9. Pentobarbital quantitation using EMIT serum barbiturate assay reagents: application to monitoring of high-dose pentobarbital therapy.

    Science.gov (United States)

    Pape, B E; Cary, P L; Clay, L C; Godolphin, W

    1983-01-01

    Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.

  10. Comparison of two enzyme-linked immunosorbent assays and one rapid immunoblot assay for detection of herpes simplex virus type 2-specific antibodies in serum

    NARCIS (Netherlands)

    Groen, J; Van Dijk, G; Niesters, H G; Van Der Meijden, W I; Osterhaus, A D

    The sensitivities and specificities of three immunoassays for the detection of herpes simplex virus type 2 (HSV-2)-specific immunoglobulin G antibodies in serum, including the one-strip rapid immunoblot assay (RIBA; Chiron Corporation) and two indirect enzyme immunosorbent assays (EIA; Gull

  11. A serum and platelet-rich plasma serotonin assay using liquid chromatography tandem mass spectrometry for monitoring of neuroendocrine tumor patients.

    Science.gov (United States)

    Korse, Catharina M; Buning-Kager, Johanna C G M; Linders, Theodora C; Heijboer, Annemieke C; van den Broek, Daan; Tesselaar, Margot E T; van Tellingen, Olaf; van Rossum, Huub H

    2017-06-01

    Serotonin is used for the diagnosis and follow-up of neuroendocrine tumors (NET). We describe the analytical and clinical validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) based serotonin assay for serum and platelet-rich plasma (PRP). An LC-MS/MS based method for serum and PRP serotonin was validated by determination of assay imprecision, carry-over, linearity, interference, recovery, sample stability and a matrix/method comparison of serum and PRP serotonin was made with whole blood serotonin. Furthermore, upper limits of normal were determined and serotonin concentrations of healthy individuals, 14 NET patients without evidence of disease and 51 NET patients with evidence of disease were compared. For serum and PRP fractions, total assay imprecision was serotonin upper limit of normal were 5.5nmol/10 9 platelet and 5.1nmol/10 9 platelet, respectively. NET patients with confirmed evidence of disease had significantly higher serum and PRP serotonin levels when compared to NET patients without evidence of disease and healthy volunteers. LC-MS/MS based serum and PRP serotonin assays were developed with suitable analytical characteristics. Furthermore, serum and PRP serotonin was found to be useful for monitoring NET patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Evaluation of the neutral comet assay for detection of alpha-particle induced DNA-double-strand-breaks

    International Nuclear Information System (INIS)

    Hofbauer, Daniela

    2010-01-01

    Aim of this study was to differentiate DNA-double-strand-breaks from DNA-single-strand-breaks on a single cell level, using the comet assay after α- and γ-irradiation. Americium-241 was used as a alpha-irradiation-source, Caesium-137 was used for γ-irradiation. Because of technical problems with both the neutral and alkaline comet assay after irradiation of gastric cancer cells and human lymphocytes, no definite differentiation of DNA-damage was possible.

  13. Detection of antibodies against H5 and H7 strains in birds: evaluation of influenza pseudovirus particle neutralization tests

    Directory of Open Access Journals (Sweden)

    Sofie Wallerström

    2014-01-01

    Full Text Available Introduction: Avian influenza viruses circulate in bird populations, and it is important to maintain and uphold our knowledge of the viral strains that are currently of interest in this context. Here, we describe the use of hemagglutinin-pseudotype retroviruses based on highly pathogenic influenza viruses for the screening of avian sera for influenza A antibodies. Our aim was also to determine whether the pseudovirus neutralization tests that we assessed were sensitive and simple to use compared to the traditional methods, including hemagglutination inhibition assays and microneutralization tests. Material and methods: H5 and H7 pseudovirus neutralization tests were evaluated by using serum from infected rabbits. Subsequently, the assays were further investigated using a panel of serum samples from avian species. The panel contained samples that were seropositive for five different hemagglutinin subtypes as well as influenza A seronegative samples. Results and discussion: The results suggest that the pseudovirus neutralization test is an alternative to hemagglutination inhibition assays, as we observed comparable titers to those of both standard microneutralizations assays as well as hemagglutinin inhibition assays. When evaluated by a panel of avian sera, the method also showed its capability to recognize antibodies directed toward low-pathogenic H5 and H7. Hence, we conclude that it is possible to use pseudoviruses based on highly pathogenic avian influenza viruses to screen avian sera for antibodies directed against influenza A subtypes H5 and H7.

  14. A rapid microtiter plate serum bactericidal assay method for determining serum complement-mediated killing of Mannheimia haemolytica.

    Science.gov (United States)

    Ayalew, Sahlu; Confer, Anthony W; Shrestha, Binu; Payton, Mark E

    2012-05-01

    In this study, we describe a rapid microtiter serum bactericidal assay (RMSBA) that can be used to measure the functionality of immune sera. It quantifies bactericidal activity of immune sera in the presence of complement against a homologous bacterium, M. haemolytica in this case. There is high correlation between data from RMSBA and standard complement-mediated bacterial killing assay (r=0.756; p<0.0001). The RMSBA activity of sera can be generated in less than 5 h instead of overnight incubation. RMSBA costs substantially less in terms of time, labor, and resources and is highly reproducible. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. The Diagnosis of Invasive and Noninvasive Pulmonary Aspergillosis by Serum and Bronchoalveolar Lavage Fluid Galactomannan Assay

    Directory of Open Access Journals (Sweden)

    Shuzhen Zhang

    2015-01-01

    Full Text Available The incidence and mortality of invasive pulmonary aspergillosis (IPA are rising, particularly in critically ill patients and patients with severe chronic obstructive pulmonary disease (COPD. Noninvasive aspergillosis occurring in these patients requires special attention because of the possibility of developing subsequent IPA, given the poor health and worsened immune state of these patients. We compared the performance of the Platelia galactomannan (GM enzyme immunoassay in the bronchoalveolar lavage fluid (BALF and serum. The sensitivity, and specificity of BALF-GM were 85.4% and 62.4%, and those of serum-GM were 67.9% and 93.5% at the cutoff index of 0.5. As the cutoff index increased, the specificity of BALF-GM detection was increased with the detriment of sensitivity. The area under the ROC curves was 0.817 (95% CI: 0.718–0.916 for BALF-GM and 0.819 (95% CI: 0.712–0.926 for serum-GM. The optimal cutoff index was 1.19 for BALF-GM, and the sensitivity and specificity were 67.9% and 89.2%. The BALF-GM assay is more sensitive in detecting pulmonary aspergillosis than serum-GM assay and fungal cultures. However, BALF-GM assay has a high false-positive rate at the cutoff index of 0.5. Hence, the diagnostic cutoff index of the BALF-GM assay should be improved to avoid the overdiagnosis of pulmonary aspergillosis in clinic.

  16. Quantification of equine immunoglobulin A in serum and secretions by a fluorescent bead-based assay.

    Science.gov (United States)

    Schnabel, Christiane L; Babasyan, Susanna; Freer, Heather; Wagner, Bettina

    2017-06-01

    Only few quantitative reports exist about the concentrations and induction of immunoglobulin A (IgA) in mucosal secretions of horses. Despite this, it is widely assumed that IgA is the predominant immunoglobulin on mucosal surfaces in the horse. Here, two new monoclonal antibodies (mAbs) against equine IgA, clones 84-1 and 161-1, were developed and characterized in detail. Both IgA mAbs specifically bound monomeric and dimeric equine IgA in different applications, such as Western blots and fluorescent bead-based assays. Cross-reactivity with other equine immunoglobulin isotypes was not observed. The new IgA mAb 84-1 was used in combination with the previously characterized anti-equine IgA mAb BVS2 for the development and validation of a fluorescent bead-based assay to quantify total IgA in equine serum and various secretions. The IgA assay's linear detection ranged from 64pg/ml to 1000ng/ml. For the quantification of IgA in serum or in secretions an IgA standard was purified from serum or nasal wash fluid (secretory IgA), respectively. The different standards were needed for accurate IgA quantification in the respective samples taking the different signal intensities of monomeric and dimeric IgA on the florescent bead-based assay into account. IgA was quantified by the bead-based assay established here in different equine samples of healthy adult individuals. In serum the median total IgA was 0.45mg/ml for Thoroughbred horses (TB, n=10) and 1.16mg/ml in Icelandic horses (ICH, n=12). In nasopharyngeal secretions of TB (n=7) 0.13mg/ml median total IgA was measured, and 0.25mg/ml for ICH (n=12). Saliva of ICH (n=6) contained a median of 0.15mg/ml, colostrum of Warmbloods (n=8) a median of 1.89mg/ml IgA. Compared to IgG1 and IgG4/7 quantified in the same samples, IgA appeared as the major immunoglobulin isotype in nasopharyngeal secretions and saliva while it is a minor isotype in serum and colostrum. The newly developed monoclonal antibodies against equine IgA and the

  17. Protective levels of canine distemper virus antibody in an urban dog population using plaque reduction neutralization test

    Directory of Open Access Journals (Sweden)

    O.I. Oyedele

    2004-11-01

    Full Text Available Blood samples from 50 dogs were collected at three veterinary clinics in Ibadan and Abuja, Nigeria and the serum from each sample was evaluated serologically for neutralizing antibodies against canine distemper virus (CDV by the highly sensitive plaque reduction (PRN neutralization assay. Thirteen dogs had plaque reduction neutralization titres of 0-100, seven had titres of 100-1 000 while 30 had titres ranging from 1 000-6 000. The PRN titres of vaccinated dogs were found to be significantly higher than unvaccinated dogs. The widespread use of the highly reproducible PRN test for the evaluation of antibody response to CDV may be very important in the generation of international CDV positive serum standards that should help to improve pre-and post-vaccination testing of dogs worldwide.

  18. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  19. Studies on the 2-site immunoradiometric assay of serum ferritin and its applications for diagnosis of iron deficiency

    International Nuclear Information System (INIS)

    Koseki, Junichi; Niitsu, Yoshiro

    1980-01-01

    The 2-site immunoradiometric assay using paper discs as a solid phase material was established for the measurement of serum ferritin. The standard curve was found the range from 0.5ng -- 500ng ferritin per ml and the sensitivity limit of the assay was 0.1ng ferritin per ml. The clinical value of serum ferritin assay was then investigated for diagnosis of iron deficiency. The mean serum ferritin concentrations of normal subjects were greater for males (119.8+-55.5ng/ml) than for females (56.5+-55.5ng/ml) although this sex difference was not distinct beyond the age of 45. All 15 patients with iron deficient anemia had serum ferritin concentrations below the normal range, whereas in other anemias including anemia associated with chronic inflammation, pernicious anemia, aplastic anemia, serum ferritin concentrations were normal oe elevated. In 116 apparently normal subjects, 13.8% of total females had abnormally low serum ferritin concentrations with normal hemoglobin levels. The cytochrome c oxidase activity of peripheral leucocytes from those subjects were generally depleted. Most of them frequently suffered from easy fatiguability, weakness, and dizziness and these complications were clearly relieved by the administration of iron. Measurement of serum ferritin was found to be quite useful for diagnosis and assessment of iron deficient states. (author)

  20. A solid phase radioimmunoassay for free triiodothyronine in serum: assay development and validation

    International Nuclear Information System (INIS)

    Liu Fangyan; Zhou Meiying; Yin Linxiang; Yang Jianzhong; Hua Chenglin

    1999-01-01

    A solid phase radioimmunoassay for free triiodothyronine in serum was developed based on double-antibody coated tubes. The method was turned out to be reliable with good reproducibility, higher sensitivity and easy performance. The measurable range of FT 3 in serum was 1.2 to 38 pmol/L. The mean coefficients of variation within and between assays were 1.79%∼3.18% and 4.72%∼9.31%, respectively. The FT 3 concentrations in euthyroid serum as determined by this method were 2.8 to 7.8 pmol/L. The FT 3 values determined by this new method correlated well with those measured by a commercial radioimmunoassay (r = 0.853)

  1. Evaluation of the Ramco kit for serum ferritin assay

    Energy Technology Data Exchange (ETDEWEB)

    Dempster, W S; Knight, G J [Red Cross War Memorial Children' s Hospital, Cape Town (South Africa). Department of Paediatrics and Child Health; Jacobs, P [Cape Town Univ. (South Africa). Dept. of Haematology

    1979-12-22

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6..mu..g/l to greater than 2 000 ..mu..g/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice.

  2. A novel assay to quantitate MASP-2/ficolin-3 complexes in serum

    DEFF Research Database (Denmark)

    Csuka, Dorottya; Munthe-Fog, Lea; Skjoedt, Mikkel-Ole

    2013-01-01

    in the circulation. The significance of lectin pathway complexes in the circulation is unknown. Thus, we established an assay for the measurement of circulating MASP-2/ficolin-3 complexes. A quantitative sandwich ELISA was developed for the measurement of the MASP-2/ficolin-3 complexes in serum based on monoclonal...

  3. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein.

    Science.gov (United States)

    Zhang, Xinsheng; Wallace, Olivia L; Domi, Arban; Wright, Kevin J; Driscoll, Jonathan; Anzala, Omu; Sanders, Eduard J; Kamali, Anatoli; Karita, Etienne; Allen, Susan; Fast, Pat; Gilmour, Jill; Price, Matt A; Parks, Christopher L

    2015-08-01

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Detection of serum anti-sperm antibody in infertile couples with dot-immunogold filtration assay (DIGFA)

    International Nuclear Information System (INIS)

    Xie Xiaoxian

    2005-01-01

    Objective: To develop a new method for rapid detection of serum anti-sperm antibody in infertile couples. Methods: Human sperm antigen was prepared from pooled semen specimens of fertile males. Nitro-cellulose membrane was used as solid-phase carrier of the antigen. Colloidal gold pellet combined goat anti-human IgG was taken as labelled antibody. A dot-immunogold filtration assay system was established for test of serum anti-human sperm antibody. Serum specimens from 137 infertile couples were tested and the result compared with flat from ELISA. Results: The human sperm antigen would react with the anti-sperm antibody in the tested serum over the cellulose membrane through filtration and the result could be read with naked eye within 6 minutes. In this study of 137 infertile coupled, the anti-sperm antibody was positive in 21.9% of the female serum specimens and 13.19% of the males. Compared with the result from ELISA, the consistency rate was 96.1%. The sensitivity of the assay was 90.2% and specificity was 95.4%. The p reparation was stable after 6 months refrigerator storage. Conclusion: This newly developed DIGFA is very adequate for rap id detection of anti-sperm antibody and deserves popularization. (authors)

  5. Immunoradiometric assay for prolactin in serum and tissue; Comparison with radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Ohnami, Shumpei; Nakata, Hajime; Eto, Sumiya (University of Occupational and Environmental Health Hospital, Kitakyushu, Fukuoka (Japan))

    1990-09-01

    Prolactin (PRL) concentrations in sera and tumors of patients with various pituitary tumors were measured by both immunoradiometric assay (IRMA) and radioimmunoassay (RIA). PRL concentrations in sera and tumor tissues measured by IRMA were well correlated with those measured by RIA. PRL concentrations in sera reflected those of tumors removed. This IRMA is a simple and useful method for PRL determination in serum and tissue. (author).

  6. Detection of canine distemper virus serum neutralizing antibodies in captive U.S. phocids.

    Science.gov (United States)

    Clancy, Meredith M; Gamble, Kathryn C; Travis, Dominic A

    2013-03-01

    Antibodies to morbilliviruses have been documented in free-ranging pinnipeds throughout populations in the Atlantic and Arctic Oceans, but not from the Pacific Ocean. As a symbolic geographic barrier between the exposed Atlantic and naive Pacific populations, the captive phocid population in North America had undocumented serologic status. In this study, canine distemper virus (CDV) serum neutralization assays were used to assess the prevalence of antibodies in this population with participation of 25 U.S. institutions from grey seals (Halichoerus grypus, n = 6) and harbor seals (Phoca vitulina, n = 108). Historic and environmental risk factors associated with the epidemiology of distemper virus were collected by survey. Based on antibodies to canine distemper virus, the prevalence of exposure in this population was 25.5%, with 28 seals (grey, n = 2; harbor, n = 26) demonstrating antibody titers > or = 1:16, and positive titers ranged from 1:4 to 1:1,536. By survey analysis, strong associations with seropositive status were identified for captive origin (P = 0.013) and movement among institutions (P = 0.024). Size of population has positive correlation with likelihood of seropositive seals at an institution (P = 0.020). However, no major husbandry or enclosure-based risk factors were identified in institutions with seropositive seals, and no interaction between individual or institutional risk factors was identified. Previously undocumented prior to this study, CDV antibodies were measured in harbor seals (n = 2) recently stranded from the Pacific coast.

  7. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    Science.gov (United States)

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  8. A comparison of sperm agglutination and immobilization assays with a quantitative ELISA for anti-sperm antibody in serum.

    Science.gov (United States)

    Lynch, D M; Leali, B A; Howe, S E

    1986-08-01

    An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.

  9. Evaluation of stat assay of serum digoxin concentration by radioimmunoassay and its application for digoxin regimen based on pharmacokinetics

    International Nuclear Information System (INIS)

    Sasaki, Yasuhito; Sato, Akemi; Shinozaki, Kimikazu; Masuhara, Keiso; Tabuse, Katsuyoshi.

    1980-01-01

    Serum digoxin concentrations measured by stat RIA (phadebas digoxin RIA kit) correlated well with results obtained by complete assays. The result of stat assay can be reported within 1 hour, measuring one or more samples together with 2 standard samples in duplicates. Precise measurement can be expected with serum digoxin concentration over 0.5 ng/ml. The stat assay allows to apply the theory of pharmacokinetics for the estimation of digoxin concentration at steady states measuring minimum digoxin concentration (C sub(n)(min)) on the 3rd to 6th day after the start of digoxin therapy. The estimated serum digoxin levels were well agreed with measured values with the difference ranging from 1.6 to 8.6% in CV. The method is usefull for the planning and assessment of appropriate digoxin regimen. (author)

  10. Comparison of the PRNT and an immune fluorescence assay in yellow fever vaccinees receiving immunosuppressive medication.

    Science.gov (United States)

    Wieten, Rosanne W; Jonker, Emile F F; Pieren, Daan K J; Hodiamont, Caspar J; van Thiel, Pieter P A M; van Gorp, Eric C M; de Visser, Adriëtte W; Grobusch, Martin P; Visser, Leo G; Goorhuis, Abraham

    2016-03-04

    The 17D-yellow fever (YF) vaccination is considered contraindicated in immune-compromised patients; however, accidental vaccination occurs. In this population, measuring the immune response is useful in clinical practice. In this study we compare two antibody tests (the Immune Fluorescence Assay and the Plaque Reduction Neutralization Test) in a group of Dutch immune-compromised travellers with a median of 33 days (IQR [28-49]) after primary YF vaccination. We collected samples of 15 immune-compromised vaccinees vaccinated with the 17D yellow fever vaccine between 2004 and 2012. All samples measured in the plaque reduction neutralization test yielded positive results (>80% virus neutralization with a 1:10 serum dilution). Immune Fluorescence Assay sensitivity was 28% (95% CI [0.12-0.49]). No adverse events were reported. All immune-compromised patients mounted an adequate response with protective levels of virus neutralizing antibodies to the 17-D YF vaccine. No adverse effects were reported. Compared to the plaque reduction neutralization test, the sensitivity of the Immune Fluorescence Assay test was low. Further research is needed to ascertain that 17D vaccination in immune-compromised patients is safe. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. High-pressure liquid chromatographic assay of Bay n 7133 in human serum.

    OpenAIRE

    Fasching, C E; Hughes, C E; Hector, R F; Peterson, L R

    1984-01-01

    A high-pressure liquid chromatographic method that includes a Sep-Pak (Waters Associates, Inc., Milford , Mass.) preparation of human serum was employed for the quantitative assay of Bay n 7133. Drug levels of 0.1 to 20 micrograms/ml could be detected. No interference from amphotericin B was found in the chromatographic analysis of Bay n 7133.

  12. Oral immunization with rotavirus VP7 expressed in transgenic potatoes induced high titers of mucosal neutralizing IgA

    International Nuclear Information System (INIS)

    Wu Yuzhang; Li Jintao; Mou Zhirong; Fei Lei; Ni Bing; Geng Miao; Jia Zhengcai; Zhou Wei; Zou Liyun; Tang Yan

    2003-01-01

    Rotaviruses (RV) are a common cause of severe diarrhea in young children, resulting in nearly one million deaths worldwide annually. Rotavirus VP7 was the rotavirus neutralizing protein. Previous study reported that VP7 DNA vaccine can induce high levels of IgG in mice but cannot protect mice against challenge (Choi, A.H., Basu, M., Rae, M.N., McNeal, M.M., Ward, R.L., 1998. Virology 250, 230-240). We found that rotavirus VP7 could maintain its neutralizing immunity when it was transformed into the potato genome. Mice immunized with the transformed tubers successfully elicited serum IgG and mucosal IgA specific for VP7. The mucosal IgA titer was as high as 1000, while serum IgG titer was only 600. Neutralizing assays indicated that IgA could neutralize rotavirus. These results indicate the potential usefulness of plants for production and delivery of edible rotavirus vaccines

  13. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  14. Global panel of HIV-1 Env reference strains for standardized assessments of vaccine-elicited neutralizing antibodies.

    Science.gov (United States)

    deCamp, Allan; Hraber, Peter; Bailer, Robert T; Seaman, Michael S; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K; Zolla-Pazner, Susan; LaBranche, Celia C; Mascola, John R; Korber, Bette T; Montefiori, David C

    2014-03-01

    Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit

  15. Novel immunoradiometric assay of thyroglobulin in serum with use of monoclonal antibodies selected for lack of cross-reactivity with autoantibodies

    International Nuclear Information System (INIS)

    Piechaczyk, M.; Baldet, L.; Pau, B.; Bastide, J.M.

    1989-01-01

    A multisite immunoradiometric assay for measurement of serum thyroglobulin (Tg), designated Magnogel-IRMA-Tg, has been developed, involving magnetic microbeads (Magnogel). This assay is based on the use of five anti-Tg monoclonal antibodies (MAbs) directed against three antigenic regions on the Tg molecule that are not recognized by anti-Tg autoantibodies (aAbs). Four of these MAbs, directed against two antigenic domains, were coupled to the magnetic beads and were used to trap the serum antigen. Another MAb, directed against the third region, was iodinated and served as the labeled second antibody. The Magnogel-IRMA-Tg technique is reproducible, rapid, and sensitive (lower detection limit, 3 micrograms/L). The assay reliably measures serum Tg in the presence of anti-Tg aAbs

  16. Highly Specific Detection of Myostatin Prodomain by an Immunoradiometric Sandwich Assay in Serum of Healthy Individuals and Patients

    Science.gov (United States)

    Widera, Christian; Gottlieb, Jens; Vogel, Arndt; Schmidt, Sebastian; Brandes, Gudrun; Heuft, Hans-Gert; Lichtinghagen, Ralf; Kempf, Tibor; Wollert, Kai C.; Bauersachs, Johann; Heineke, Joerg

    2013-01-01

    Background Myostatin is a muscle derived factor that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in rodent models of muscle wasting and in cachectic patients with cancer or pulmonary disease. Therefore, there is an increasing interest to use serum myostatin as a biomarker. Methods We established an immunoradiometric sandwich assay (IRMA), which uses a commercially available chicken polyclonal, affinity purified antibody directed against human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals as well as 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic pulmonary disease. Results The IRMA had a detection limit of 0.7ng/ml, an intraassay imprecision of ≤14.1% and an interassay imprecision of ≤ 18.9%. The specificity of our assay was demonstrated by size exclusion chromatography, detection of myostatin by Western-blotting and a SMAD-dependent transcriptional-reporter assay in the signal-rich serum fractions, as well as lack of interference by unspecific substances like albumin, hemoglobin or lipids. Myostatin prodomain was stable at room temperature and resistant to freeze-thaw cycles. Apparently healthy individuals over the age of 55 had a median myostatin prodomain serum concentration of 3.9ng/ml (25th-75th percentiles, 2-7ng/ml) and we could not detect increased levels in patients with stable chronic heart failure or cancer related weight loss. In contrast, we found strongly elevated concentrations of myostatin prodomain (median 26.9ng/ml, 25th-75th percentiles, 7-100ng/ml) in the serum of underweight patients with chronic pulmonary disease. Conclusions We established a highly specific IRMA for the quantification of myostatin prodomain concentration in human serum. Our assay could be useful to study myostatin as a biomarker for example in patients with chronic pulmonary disease, as we detected highly

  17. A novel cell-based assay for measuring neutralizing autoantibodies against type I interferons in patients with autoimmune polyendocrine syndrome type 1.

    Science.gov (United States)

    Breivik, Lars; Oftedal, Bergithe E V; Bøe Wolff, Anette S; Bratland, Eirik; Orlova, Elizaveta M; Husebye, Eystein S

    2014-07-01

    An important characteristic of autoimmune polyendocrine syndrome type 1 (APS 1) is the existence of neutralizing autoantibodies (nAbs) against the type I interferons (IFN) -α2 and -ω at frequencies close to 100%. Type 1 IFN autoantibodies are detected by antiviral neutralizing assays (AVA), binding assays with radiolabelled antigens (RLBA), enzyme-linked immunosorbent assay (ELISA), or by reporter-based cell assays. We here present a simple and reliable version of the latter utilizing a commercially available cell line (HEK-Blue IFN-α/β). All 67 APS 1 patients were positive for IFN-ω nAbs, while 90% were positive for IFN-α2 nAbs, a 100% and 96% correlation with RLBA, respectively. All blood donors and non-APS 1 patients were negative. The dilution titer required to reduce the effect of IFN-ω nAbs correlated with the RLBA index. This cell-based autoantibody assay (CBAA) is easy to perform, suitable for high throughput, while providing high specificity and sensitivity. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    Science.gov (United States)

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  19. Thermometric enzyme linked immunosorbent assay in continuous flow system: optimization and evaluation using human serum albumin as a model system.

    Science.gov (United States)

    Borrebaeck, C; Börjeson, J; Mattiasson, B

    1978-06-15

    Thermometric enzyme-linked immunosorbent assay (TELISA) is described. After the procedure of optimization, human serum albumin was assayed using anti-human serum albumin bound to Sepharose CL 4-B in the enzyme thermistor unit and catalase as label on the free antigen. The model system was used for assays down to 10(-13)M and the preparation of immobilized antibodies was used repeatedly up to 100 times. Comparative studies of the TELISA technique with bromocresol green, immunoturbidimetric and rocket immunoelectrophoretic methods were carried out and showed that TELISA could be used as an alternative method.

  20. Clinical significance of serum thymosin α1 assay in tumor patients

    International Nuclear Information System (INIS)

    Wang Jiamin; Lv Ming'en; Zhao Xiaojuan; Gao Weiqiang; Bai Xia; Wang Zhaoyue

    2003-01-01

    Objective: To investigate the clinical significance of thymosin α1(Tα1) measurement in evaluating clinical status of patients with solid malignant tumors. Methods: Tα1 levels in serum of 50 normal adults, 20 patients with benign tumors and 63 patients with malignant tumors were measured by enzyme linked immunosorbent assay (ELISA). The association of Tα1 level with tumor invasion, metastasis and its alteration after different treatment in patients with malignant tumors were also studied. Results: The serum Tα1 level was 0.69±0.35 μg/L in normal adults, 0.96±0.37 μg/L in patients with benign tumors and 1.46±0.90 μg/L in patients with malignant tumors. In comparison it was both increased between patients with benign and malignant tumors and the normal adults (P<0.01 and P<0.001). And its increasing extent in malignant tumors was much greater than that in benign tumors (P<0.05). The serum Tα1 level in patients with malignant tumors was correlated with tumor invasion, metastasis and different treatment intervention. Conclusions: Our findings suggest that the serum Tα1 level be increased in tumor patients, and that it may be used as a new tumor marker in clinic

  1. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  2. An evaluation of the Ramco kit for serum ferritin assay

    International Nuclear Information System (INIS)

    Dempster, W.S.; Knight, G.J.; Jacobs, P.

    1979-01-01

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6μg/l to greater than 2 000 μg/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice

  3. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  4. Cross-reactivity and phospholipase A2 neutralization of anti-irradiated Bothrops jararaca venom antibodies

    International Nuclear Information System (INIS)

    Spencer, P.J.; Nascimento, N. do; Paula, R.A. de; Cardi, B.A.; Rogero, J.R.

    1995-01-01

    The detoxified Bothrops jararaca venom, immunized rabbits with the toxoid obtained and investigated cross-reactivity of the antibodies obtained against autologous and heterelogous venoms was presented. It was also investigated the ability of the IgGs, purified by affinity chromatography, from those sera to neutralize phospholipase. A 2 , an ubiquous enzyme in animal venoms. Results indicate that venom irradiation leads to an attenuation of toxicity of 84%. Cross-reactivity was investigated by ELISA and Western blot and all venoms were reactive to the antibodies. On what refers to phospholipase A 2 activity neutralization, the antibodies neutralized autologous venoms efficiently and, curiously, other venoms from the same genus were not neutralized, while Lachesis muta venom, a remote related specier, was neutralized by this serum. These data suggest that irradiation preserve important epitopes for induction of neutralizing antibodies and that these epitopes are not shared by all venoms assayed. (author). 8 refs, 2 figs, 3 tabs

  5. Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Andresen, Lars Ole; Klausen, Joan; Barfod, Kristen

    2002-01-01

    and from herds declared free of infection with Ap. The Ap serotype 12 blocking ELISA showed a herd sensitivity of 0.77 (95% confidence interval, 0.62-0.88) and a herd specificity of 1.00 (0.95-1.00) with a cut-off value at 40% relative absorbance or 60% inhibition. The assay may be used advantageously......The objective was to develop a blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Actinobacillus pleuropneumoniae (Ap) serotype 12 in pig serum. Lipopolysaccharide (LPS) from Ap serotype 12 was purified and used as antigen in the assay. Antibodies to the LPS antigen...... in samples of pig serum were detected by inhibition of the binding of polyclonal rabbit antibodies raised against Ap serotype 12. The assay was evaluated against sera from experimentally infected pigs, from pig herds naturally infected with Ap and from herds declared free of Ap serotypc 12 infection...

  6. Analytical validation of a new point-of-care assay for serum amyloid A in horses.

    Science.gov (United States)

    Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M

    2018-01-17

    Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the

  7. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  8. Comparison of seven serum thyroglobulin assays in the follow-up of papillary and follicular thyroid cancer patients.

    Science.gov (United States)

    Schlumberger, M; Hitzel, A; Toubert, M E; Corone, C; Troalen, F; Schlageter, M H; Claustrat, F; Koscielny, S; Taieb, D; Toubeau, M; Bonichon, F; Borson-Chazot, F; Leenhardt, L; Schvartz, C; Dejax, C; Brenot-Rossi, I; Torlontano, M; Tenenbaum, F; Bardet, S; Bussière, F; Girard, J J; Morel, O; Schneegans, O; Schlienger, J L; Prost, A; So, D; Archambeaud, F; Ricard, M; Benhamou, E

    2007-07-01

    Serum thyroglobulin (Tg) is the marker of differentiated thyroid cancer after initial treatment and TSH stimulation increases its sensitivity for the diagnosis of recurrent disease. The goal of the study is to compare the diagnostic values of seven methods for serum Tg measurement for detecting recurrent disease both during L-T4 treatment and after TSH stimulation. Thyroid cancer patients who had no evidence of persistent disease after initial treatment (total thyroidectomy and radioiodine ablation) were studied at 3 months on L-T4 treatment (Tg1) and then at 9-12 months after withdrawal or recombinant human TSH stimulation (Tg2). Sera with anti-Tg antibodies or with an abnormal recovery test result were excluded from Tg analysis with the corresponding assay. The results of serum Tg determination were compared to the clinical status of the patient at the end of follow-up. Thirty recurrences were detected among 944 patients. A control 131I total body scan had a low sensitivity, a low specificity, and a low clinical impact. Assuming a common cutoff for all Tg assays at 0.9 ng/ml, sensitivity ranged from 19-40% and 68-76% and specificity ranged from 92-97% and 81-91% for Tg 1 and Tg2, respectively. Using assays with a functional sensitivity at 0.2-0.3 ng/ml, sensitivity was 54-63% and specificity was 89% for Tg1. Using the two methods with a lowest functional sensitivity at 0.02 and 0.11 ng/ml resulted in a higher sensitivity for Tg1 (81% and 78%), but at the expense of a loss of specificity (42% and 63%); finally, for these two methods, using an optimized functional sensitivity according to receiver operating characteristic curves at 0.22 and 0.27 ng/ml resulted in a sensitivity at 65% and specificity at 85-87% for Tg1. Using an assay with a lower functional sensitivity may give an earlier indication of the presence of Tg in the serum on L-T4 treatment and may be used to study the trend in serum Tg without performing any TSH stimulation. Serum Tg determination

  9. A simple micro-extraction plate assay for automated LC-MS/MS analysis of human serum 25-hydroxyvitamin D levels.

    Science.gov (United States)

    Geib, Timon; Meier, Florian; Schorr, Pascal; Lammert, Frank; Stokes, Caroline S; Volmer, Dietrich A

    2015-01-01

    This short application note describes a simple and automated assay for determination of 25-hydroxyvitamin D (25(OH)D) levels in very small volumes of human serum. It utilizes commercial 96-well micro-extraction plates with commercial 25(OH)D isotope calibration and quality control kits. Separation was achieved using a pentafluorophenyl liquid chromatography column followed by multiple reaction monitoring-based quantification on an electrospray triple quadrupole mass spectrometer. Emphasis was placed on providing a simple assay that can be rapidly established in non-specialized laboratories within days, without the need for laborious and time consuming sample preparation steps, advanced calibration or data acquisition routines. The analytical figures of merit obtained from this assay compared well to established assays. To demonstrate the applicability, the assay was applied to analysis of serum samples from patients with chronic liver diseases and compared to results from a routine clinical immunoassay. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Radioreceptor assay for 1,25-dihydroxyvitamin D3 in serum and its application in the study of rachitis

    International Nuclear Information System (INIS)

    Shi Yuyuan; Zhang Peiyin; Li Yajuan

    1988-01-01

    A modifed radioreceptor assay for 1,25-(OH) 2 -D 3 (1,25-Dihydroxy vitamin D 3 , Dihydroxycholecalciferol, DHCC) in serum was established, which was proved to have high sensitivity, stability and accuracy, and was applied in patients with rachitis. The results showed that DHCC level in serum in rachictic patients was lower than that of the control. The detection rate of DHCC was obviously higher than that through symptoms, laboratory tests and X-ray examination in patients with rachitis. Therefore, this assay technique can be used as a sensitive indicator for diagnosis of rachitis. It was also found that DHCC level in mothers was cor-relative with their infants, so that assay for DHCC level in pregnant mothers has significance in prevention and treatment of rachitis in their infants

  11. Serum IFN neutralizing antibodies and neopterin levels in a cross-section of MS patients.

    Science.gov (United States)

    Cook, S D; Quinless, J R; Jotkowitz, A; Beaton, P

    2001-09-25

    To determine levels of serum interferon beta (IFNbeta) neutralizing antibody (NAb) and neopterin-an IFN biologic response marker-in patients with MS treated with Betaseron or Avonex. Controversy exists over the relative immunogenicity of IFNbeta-1a and IFNbeta-1b and the reasons for any such difference. To determine the role of patient profile and test methodology in IFNbeta, NAb levels need to be measured blindly and simultaneously in a predefined closely matched MS patient cohort. Serum NAb and neopterin levels were measured in closely matched patients on Avonex (n = 98) or Betaseron (n = 64). NAb were determined by Athena Diagnostics and serum neopterin levels by Covance Laboratories using a competitive binding radioimmunoassay. More patients taking Betaseron (22%) than Avonex (7%) had elevated titers of NAb (p = 0.008). Mean serum neopterin levels were lower in patients with high as compared to low NAb titers (p = 0.0002). No difference in mean neopterin levels was found comparing the total Betaseron group to the Avonex group; however, in the subset of patients with low NAb titers, mean neopterin levels were higher in the Betaseron than in the Avonex group (p = 0.027). A random cross-sectional sampling of patients on Avonex showed a decrease in neopterin levels over time between weekly doses. NAb are more commonly found with Betaseron than Avonex. More studies are needed to determine the correlation among serum neopterin levels, other biologic response markers, NAb, and disease activity in patients with MS being treated with IFNbeta.

  12. Reporter gene assay for the quantification of the activity and neutralizing antibody response to TNFα antagonists

    DEFF Research Database (Denmark)

    Lallemand, Christophe; Kavrochorianou, Nadia; Steenholdt, Casper

    2011-01-01

    A cell-based assay has been developed for the quantification of the activity of TNFα antagonists based on human erythroleukemic K562 cells transfected with a NFκB regulated firefly luciferase reporter-gene construct. Both drug activity and anti-drug neutralizing antibodies can be quantified...... with a high degree of precision within 2h, and without interference from cytokines and other factors known to activate NFκB. The assay cells also contain the Renilla luciferase reporter gene under the control of a constitutive promoter that allows TNFα-induced firefly luciferase activity to be normalized...... relative to Renilla luciferase expression. Thus, results are independent of cell number or differences in cell viability, resulting in intra and inter assay coefficients of variation of 10% or less. Normalization of results relative to the expression of an internal standard also provides a means...

  13. Clinical evaluation of the Serum CrossLaps One Step ELISA, a new assay measuring the serum concentration of bone-derived degradation products of type I collagen C-telopeptides

    DEFF Research Database (Denmark)

    Christgau, S; Rosenquist, C; Alexandersen, P

    1998-01-01

    The Serum CrossLaps One Step ELISA is a sandwich assay using two monoclonal antibodies specific for a beta-aspartate form of the epitope EKAHDGGR derived from the carboxy-terminal telopeptide region of type I collagen alpha1-chain. Our objective was to assess the clinical value of the Serum Cross...

  14. The accuracy of serum galactomannan assay in diagnosing invasive pulmonary aspergillosis.

    Science.gov (United States)

    Sarrafzadeh, Shokooh Azam; Hoseinpoor Rafati, Ali; Ardalan, Maryam; Mansouri, Davood; Tabarsi, Payam; Pourpak, Zahra

    2010-09-01

    Galactomannan (GM) antigen is an aspergillus specific antigen that is released during the growth phase of invasive aspergillosis. We aimed to find the optimum cutoff and accuracy of serum Galactomannan assay in immunocompromised patients. Immunocompromised patients diagnosed with invasive pulmonary aspergillosis (IPA) based on the European Organization for Research and Treatment of Cancer/Invasive Mycosis Study Group (EORTC/MSG) with three levels of certainty proven, probable and possible, referred for GM antigen measurement at Immunology, Asthma and Allergy Research Institute (IAARI) from 2006 to 2009 and if they met the criteria were enrolled in this study. Totally 49 patients with IPA were enrolled in our study. According to EORTC/MSG, patients categorized into three levels of certainty: They were diagnosed as 'proven' invasive pulmonary aspergillosis 16(32.7%), 'probable' 18(36.7%) and 'possible' 15(30.6%). The most common host risk factor was solid tumors 17(34.7%). The accuracy of Galactomannan assay increased from 0.5 to 2 cutoffs. The optimum sensitivity and specificity obtained at the index cutoff of ≥1.5 for diagnosis of "proven" IPA; which were respectively, 69.2% and 72.2%. Other cutoffs had high variance between sensitivity and specificity for diagnosis of IPA. The calculated cutoff gained by receiver operating characteristic (ROC) analysis for detecting proven IPA was 1.5. Intermediate accuracy of serum GM test in conjunct with clinical findings would help early IPA detection among immunocompromised patients.

  15. An immunoradiometric assay for Helicobacter pylori urease B in serum

    International Nuclear Information System (INIS)

    Bai Yanyan; Wang Zhaoyue; Bai Xia; Ruan Changgen; Miao Jingcheng; Gu Guanbing

    2008-01-01

    Objective: The aim of this study was to establish and evaluate a novel immunoradiometric assay (IRMA) for detecting helicobacter pylori (HP) urease B (ureB) in serum. Methods: HP ureB was prepared by the DNA recombinant technique. Monoclonal antibodies against HP ureB were produced by hybridoma technique and were used to establish IRMA for detecting HP ureB. Fifty patients with chronic gastric diseases were recruited in this study, including 36 with gastric ulcer disease, 9 with chronic gastritis and 5 with gastric cancer. The IRMA was compared with rapid urease test (RUT), polymerase chain reaction (PCR) test and direct-ELISA test of serum anti-ureB antibody, using HP culture from gastric biopsy samples as a 'golden standard'. Results: The sensitivity and specificity of IRMA for HP ureB were 94.6% and 76.9%, respectively, with positive and negative predictive values being 92.1% and 83.3%. The sensitivity and specificity of RUT, PCR and serum anti-ureB antibody test were 94.6% and 23.1% , 66.8% and 84.6%, 86.5% and 38.5%, respectively. IRMA and the test of serum anti-ureB antibody was not significantly different from the 'golden standard' (X 2 =1.165, P>0.05), but RUT and PCR showed statistically significant difference with the 'gold standard' (X 2 =5.333, 9.436; all P<0.05). Conclusion: IRMA for HP ureB antigen is a sensitive and specific method for detection of HP infection, and can be used in the study of etiology and pathogenesis of gastric and some other related diseases. (authors)

  16. Sensitive assays enable detection of serum IgG antibodies against Clostridium difficile toxin A and toxin B in healthy subjects and patients with Clostridium difficile infection.

    Science.gov (United States)

    Zhao, Xuemei; Bender, Florent; Shukla, Rajiv; Kang, John J; Caro-Aguilar, Ivette; Laterza, Omar F

    2016-04-01

    Pathogenic Clostridium difficile produces two proinflammatory exotoxins, toxin A and toxin B. Low level of serum antitoxin IgG antibodies is a risk factor for the development of primary and recurrent C. difficile infection (CDI). We developed and validated two sensitive, titer-based electrochemiluminescence assays for the detection of serum antibody levels against C. difficile toxins A and B. These assays demonstrated excellent precision. The sensitivity of the assays allowed the detection of antitoxin A and antitoxin B IgG antibodies in all tested serum samples during assay validation. The validated titer-based assays enable assessment of antitoxin A and antitoxin B IgG antibodies as potential biomarkers to identify patients with CDI at increased risk for CDI recurrence.

  17. Serum neutralizing activities from a Beijing homosexual male cohort infected with different subtypes of HIV-1 in China.

    Directory of Open Access Journals (Sweden)

    Mingshun Zhang

    Full Text Available Protective antibodies play a critical role in an effective HIV vaccine; however, eliciting antibodies to block infection by viruses from diverse genetic subtypes remains a major challenge. As the world's most populous country, China has been under the threat of at least three major subtypes of circulating HIV-1 viruses. Understanding the cross reactivity and specificities of serum antibody responses that mediate broad neutralization of the virus in HIV-1 infected Chinese patients will provide valuable information for the design of vaccines to prevent HIV-1 transmission in China. Sera from a cohort of homosexual men, who have been managed by a major HIV clinical center in Beijing, China, were analyzed for cross-sectional neutralizing activities against pseudotyped viruses expressing Env antigens of the major subtype viruses (AE, BC and B subtypes circulating in China. Neutralizing activities in infected patients' blood were most capable of neutralizing viruses in the homologous subtype; however, a subset of blood samples was able to achieve broad neutralizing activities across different subtypes. Such cross neutralizing activity took 1-2 years to develop and CD4 binding site antibodies were critical components in these blood samples. Our study confirmed the presence of broadly neutralizing sera in China's HIV-1 patient population. Understanding the specificity and breadth of these neutralizing activities can guide efforts for the development of HIV vaccines against major HIV-1 viruses in China.

  18. Study of serum TSH content in functioning thyroid gland adenoma by 'supersensitive' immunoradiometric assay

    International Nuclear Information System (INIS)

    Foeldes, Janos; Banos, Csaba; Csillag, Jozsef; Lakatos, Peter; Tarjan, Gabor; 2546970HU)

    1987-01-01

    Determinations of serum TSH levels by immunoradiometric assay (IRMA)-math TSH (Mallinckrodt) kit and of the thyroid function by scintiscanning using 99m Tc-pertechnetate (20-40 MBq) were carried out paralelly in euthyroid and hyperthyroid patients. A comparison of the two tests allowed a better distinction of preclinical hyperthyreosis from toxic adenomas. (L.E.)

  19. Salivary anti-coxsackievirus-B4 neutralizing activity and pattern of immune parameters in patients with type 1 diabetes: a pilot study.

    Science.gov (United States)

    Nekoua, Magloire Pandoua; Yessoufou, Akadiri; Alidjinou, Enagnon Kazali; Badia-Boungou, Francis; Moutairou, Kabirou; Sane, Famara; Hober, Didier

    2018-05-17

    Enteroviruses, especially coxsackieviruses B (CV-B), have been associated with the pathogenesis of type 1 diabetes (T1D). An anti-CV-B4 neutralizing activity in saliva of T1D patients was previously reported. Our aim was to study the association between the saliva anti-CV-B4 neutralizing activity and immune parameters in T1D patients in comparison with non-diabetic individuals. Saliva and blood samples were collected from 15 T1D patients and 8 controls. The anti-CV-B4 and anti-poliovirus type 1 (PV-1) activities of saliva and serum samples were determined by a plaque neutralization assay. Quantification of serum cytokines was performed by ELISA and the frequencies of lymphocyte subsets were evaluated using flow cytometry. The levels of salivary anti-CV-B4 neutralizing activity were higher in T1D patients than in controls (p = 0.02), whereas the serum levels of anti-CV-B4 neutralizing activity and the saliva and serum levels of anti-PV-1 neutralizing activity were not different. The proportions of effector CD4 + T cells and CD19 + B cells, but not those of CD4 + T cells, CD8 + T cells and Foxp3 + regulatory T cells, were higher in T1D patients than in controls (p = 0.02 and p = 0.01 respectively). Moreover, serum IFN-γ levels were lower in T1D patients compared to controls (p = 0.03) while IL-4 and IL-10 were not different. There was an association between saliva anti-CV-B4 activity, down-regulation of IFN-γ and B cell expansion in peripheral blood of T1D patients. The association between saliva anti-CV-B4 activity and disturbance of immune system in T1D patients deserves further investigation.

  20. Prediction of Protection against Asian Enterovirus 71 Outbreak Strains by Cross-neutralizing Capacity of Serum from Dutch Donors, The Netherlands

    NARCIS (Netherlands)

    van der Sanden, Sabine M. G.; Koen, Gerrit; van Eijk, Hetty; Koekkoek, Sylvie M.; de Jong, Menno D.; Wolthers, Katja C.

    2016-01-01

    Outbreaks of human enterovirus 71 (EV-71) in Asia are related to high illness and death rates among children. To gain insight into the potential threat for the population of Europe, we determined the neutralizing activity in intravenous immunoglobulin (IVIg) batches and individual serum samples from

  1. An Improved Neutral a-Glucosidase Assay for Assessment of Epididymal Function—Validation and Comparison to the WHO Method

    Directory of Open Access Journals (Sweden)

    Frank Eertmans

    2014-01-01

    Full Text Available Neutral a-glucosidase (NAG activity in human seminal plasma is an important indicator for epididymis functionality. In the present study, the classic World Health Organization (WHO method has been adapted to enhance assay robustness. Changes include modified enzyme reaction buffer composition and usage of an alternative enzyme inhibitor for background correction (glucose instead of castanospermine. Both methods have been tested in parallel on 144 semen samples, obtained from 94 patients/donors and 50 vasectomized men (negative control, respectively. Passing-Bablok regression analysis demonstrated equal assay performance. In terms of assay validation, analytical specificity, detection limit, measuring range, precision, and cut-off values have been calculated. These data confirm that the adapted method is a reliable, improved tool for NAG analysis in human semen.

  2. Serum gonadotropins levels in childhood. Critical comparison between immunoradiometric assays and radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Hertogh, R. De; Vankrieken, L. (Physiology of Human Reproduction Research Unit, University of Louvain, School of Medicine, Brussels (Belgium)); Wolter, R.; Vliet, G. Van (Hopital Universitaire des Enfants, Reine Fabiola, Free University of Brussels (Belgium))

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author).

  3. Ternary mixed-mode silica sorbent of solid-phase extraction for determination of basic, neutral and acidic drugs in human serum.

    Science.gov (United States)

    Jin, Shupei; Qiao, Yinghua; Xing, Jun

    2018-06-01

    In this study, a ternary mixed-mode silica sorbent (TMSS) with octamethylene, carboxyl, and amino groups was prepared via Cu(I)-catalyzed azide-alkyne cycloaddition (CuAAC) click reaction and a subsequent reduction of azide to primary amine. While used in solid-phase extraction (SPE), the retention behavior of TMSS towards a total of nine kinds of basic, neutral, and acidic drugs was investigated in detail. The results revealed that hydrophobic, ion-exchange interaction, and electrostatic repulsion between TMSS and the analytes were closely related to the retention behavior of TMSS. Besides, the log K ow value of the analyte was also a factor influencing the retention behavior of analytes on TMSS. The nine analytes could be retained by TMSS simultaneously and then, were eluted into two fractions according to the acid-base property of the analytes for further determinations. The acidic and neutral analytes were in one fraction, and the basic ones in the other fraction. When used to treat the human serum spiked with the nine drugs, TMSS offered higher recoveries than BakerBond CBA and comparable recoveries to Oasis WCX. It should be noted TMSS had better purifying capability for human serum than Oasis WCX. Under the optimized SPE conditions, a method of SPE hyphenated to high-performance liquid chromatography-ultraviolet detection (HPLC-UV) for determination of the basic, neutral, and acidic drugs spiked in human serum was established. For the nine drugs, the linear ranges were all between 5.0 and 1000 μg L -1 with correlation coefficients (R 2 ) above 0.9990, and the limits of detection (LODs) were in the range of 0.8-2.3 μg L -1 . The intra-day and inter-day relative standard deviations (RSDs) were less than 5.3 and 8.8%, respectively. Graphical abstract Treating drugs in human serum by SPE with ternary mixed-mode silica sorbent.

  4. Serum bactericidal assay for the evaluation of typhoid vaccine using a semi-automated colony-counting method.

    Science.gov (United States)

    Jang, Mi Seon; Sahastrabuddhe, Sushant; Yun, Cheol-Heui; Han, Seung Hyun; Yang, Jae Seung

    2016-08-01

    Typhoid fever, mainly caused by Salmonella enterica serovar Typhi (S. Typhi), is a life-threatening disease, mostly in developing countries. Enzyme-linked immunosorbent assay (ELISA) is widely used to quantify antibodies against S. Typhi in serum but does not provide information about functional antibody titers. Although the serum bactericidal assay (SBA) using an agar plate is often used to measure functional antibody titers against various bacterial pathogens in clinical specimens, it has rarely been used for typhoid vaccines because it is time-consuming and labor-intensive. In the present study, we established an improved SBA against S. Typhi using a semi-automated colony-counting system with a square agar plate harboring 24 samples. The semi-automated SBA efficiently measured bactericidal titers of sera from individuals immunized with S. Typhi Vi polysaccharide vaccines. The assay specifically responded to S. Typhi Ty2 but not to other irrelevant enteric bacteria including Vibrio cholerae and Shigella flexneri. Baby rabbit complement was more appropriate source for the SBA against S. Typhi than complements from adult rabbit, guinea pig, and human. We also examined the correlation between SBA and ELISA for measuring antibody responses against S. Typhi using pre- and post-vaccination sera from 18 human volunteers. The SBA titer showed a good correlation with anti-Vi IgG quantity in the serum as determined by Spearman correlation coefficient of 0.737 (P measure functional antibody titers against S. Typhi in sera from human subjects immunized with typhoid vaccines. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Optimization of a colorimetric assay for glycosylated human serum albumin

    International Nuclear Information System (INIS)

    Bohney, J.P.; Feldhoff, R.C.

    1986-01-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100 0 C. A NaBH 4 reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with [ 3 H]glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation

  6. Measurement of cetuximab and panitumumab-unbound serum EGFR extracellular domain using an assay based on slow off-rate modified aptamer (SOMAmer reagents.

    Directory of Open Access Journals (Sweden)

    Noh Jin Park

    Full Text Available Response to cetuximab (Erbitux® and panitumumab (Vectibix® varies among individuals, and even those who show response ultimately gain drug resistance. One possible etiologic factor is differential interaction between the drug and target. We describe the development of an assay based on Slow Off-rate Modified Aptamer (SOMAmer(™ reagents that can distinguish drug-bound from unbound epidermal growth factor receptor (EGFR.This quantitative assay uses a SOMAmer reagent specific for EGFR extracellular domain (ECD as a capturing reagent. Captured SOMAmer is quantitated using PCR. Linearity and accuracy (recovery of the assay were assessed using normal sera and purified EGFR ECD.This EGFR ECD assay showed linearity between 2.5 and 600 ng/mL. Average recovery was 101%. The assay detected EGFR but showed little cross-reactivity to other ErbB proteins: 0.4% for ErbB2, 6.9% for ErbB3, and 1.3% for ErbB4. Preincubation of normal serum with either cetuximab or panitumumab resulted in a dose-dependent decrease in EGFR ECD levels measured using the SOMAmer assay; preincubation did not affect measurement with an ELISA.This SOMAmer-based serum EGFR ECD assay accurately and specifically measures EGFR in serum. Detection of significant amounts of drug-unbound EGFR in patients undergoing cetuximab or panitumumab treatment could be an indicator of poor drug response. Further studies are needed to evaluate the utility of the assay as an indicator of drug efficacy or as a guide to dosing.

  7. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    Science.gov (United States)

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  8. Impact of host cell variation on the neutralization of HIV-1 in vitro.

    Science.gov (United States)

    Polonis, Victoria R; Schuitemaker, Hanneke; Bunnik, Evelien M; Brown, Bruce K; Scarlatti, Gabriella

    2009-09-01

    In this review we present current advances in our understanding of HIV-1 neutralization assays that employ primary cell types, as compared with those that utilize cell lines and the newer, more standardized pseudovirus assays. A commentary on the challenges of standardizing in-vitro neutralization assays using primary cells is included. The data from reporter cell line neutralization assays may agree with results observed in primary cells; however, exceptions have recently been reported. Multiple variables exist in primary cell assays using peripheral blood mononuclear cells from HIV-seronegative donors; in-vitro neutralization titers can vary significantly based on the donor cells used for assay targets and for virus propagation. Thus, more research is required to achieve validated primary cell neutralization assays. HIV-vaccine-induced antibody performance in the current neutralization assays may function as a 'gatekeeper' for HIV-1 subunit vaccine advancement. Development of standardized platforms for reproducible measurement of in-vitro neutralization is therefore a high priority. Given the considerable variation in results obtained from some widely applied HIV neutralization platforms, parallel evaluation of new antibodies using different host cells for assay targets, as well as virus propagation, is recommended until immune correlates of protection are identified.

  9. Development and validation of cell-based luciferase reporter gene assays for measuring neutralizing anti-drug antibodies against interferon beta

    DEFF Research Database (Denmark)

    Hermanrud, Christina; Ryner, Malin; Luft, Thomas

    2016-01-01

    a normal distribution for the majority of runs, allowing a parametric approach for cut-point calculation to be used, where NAb positive samples could be identified with 95% confidence. An analysis of means and variances indicated that a floating cut-point should be used for all assays. The assays......Neutralizing anti-drug antibodies (NAbs) against therapeutic interferon beta (IFNβ) in people with multiple sclerosis (MS) are measured with cell-based bioassays. The aim of this study was to redevelop and validate two luciferase reporter-gene bioassays, LUC and iLite, using a cut-point approach...... to identify NAb positive samples. Such an approach is favored by the pharmaceutical industry and governmental regulatory agencies as it has a clear statistical basis and overcomes the limitations of the current assays based on the Kawade principle. The work was conducted following the latest assay guidelines...

  10. Performance Characteristics of CA 19-9 Radioimmunoassay and Clinical Significance of Serum CA 19-9 Assay in Patients with Malignancy

    International Nuclear Information System (INIS)

    Kim, Sang Eun; Shong, Young Kee; Cho, Bo Youn; Kim, Noe Kyeong; Koh, Chang Soon; Lee, Mun Ho; Hong, Seong Woon; Hong, Kee Suk

    1985-01-01

    To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum. CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. The results were as follows; 1) The CA 19-9 radioimmunoassay was simple to perform and can be completed in one work day. And the between-assay reproducibility and the assay recovery were both excellent. 2) The mean serum CA 19-9 level in 135 normal controls was 8.4±4.2 U/mL. Normal upper limit of serum CA 19-9 was defined as 21.0 U/mL. 4 out of 135 (3.0%) normal controls showed elevated CA 19-9 levels above the normal upper limit. 3) One out of 20 (5.0%) patients with benign gastrointestinal diseases showed elevated serum CA 19-9 level above the normal upper limit. 4) In 81 patients with various untreated malignancy, 41 patients (50.6%) showed elevated serum CA 19-9 levels. 66.7% of 18 patients with colorectal cancer, 100% of 2 patients with pancreatic cancer, 100% of 3 patients with common bile duct cancer, 47.1% of 17 patients with stomach cancer, 28.6% of 28 patients with hepatoma and 60.0% of 5 gastrointestinal tract cancers showed elevated serum CA 19-9 levels. 5) The sensitivities of serum CA 19-9 related to respectability in colorectal and stomach cancer were 33.3% in resectable colorectal cancer, 83.3% in unresectable colorectal cancer, 41.7% in resectable stomach cancer, 60.0% in unresectable stomach cancer respectively. 6) The sensitivity of serum CA 19-9 in 9 patients of postoperative colorectal cancer without recurrence were 33.3% and significantly decreased compared with that of untreated colorectal cancer, 66.7% (p<0.05). 7) In Patients with colorectal cancer

  11. Adaptation of the neutral bacterial comet assay to assess antimicrobial-mediated DNA double-strand breaks in Escherichia coli

    Science.gov (United States)

    SOLANKY, DIPESH; HAYDEL, SHELLEY E.

    2012-01-01

    This study aimed to determine the mechanism of action of a natural antibacterial clay mineral mixture, designated CB, by investigating the induction of DNA double-strand breaks (DSBs) in Escherichia coli. To quantify DNA damage upon exposure to soluble antimicrobial compounds, we modified a bacterial neutral comet assay, which primarily associates the general length of an electrophoresed chromosome, or comet, with the degree of DSB-associated DNA damage. To appropriately account for antimicrobial-mediated strand fragmentation, suitable control reactions consisting of exposures to water, ethanol, kanamycin, and bleomycin were developed and optimized for the assay. Bacterial exposure to the CB clay resulted in significantly longer comet lengths, compared to water and kanamycin exposures, suggesting that the induction of DNA DSBs contributes to the killing activity of this antibacterial clay mineral mixture. The comet assay protocol described herein provides a general technique for evaluating soluble antimicrobial-derived DNA damage and for comparing DNA fragmentation between experimental and control assays. PMID:22940101

  12. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  13. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals.

    Science.gov (United States)

    Davis, Rachel; Giguère, Steeve

    2005-11-15

    To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.

  14. Elevated Levels of SOX10 in Serum from Vitiligo and Melanoma Patients, Analyzed by Proximity Ligation Assay.

    Directory of Open Access Journals (Sweden)

    Andries Blokzijl

    Full Text Available The diagnosis of malignant melanoma currently relies on clinical inspection of the skin surface and on the histopathological status of the excised tumor. The serum marker S100B is used for prognostic estimates at later stages of the disease, but analyses are marred by false positives and inadequate sensitivity in predicting relapsing disorder.To investigate SOX10 as a potential biomarker for melanoma and vitiligo.In this study we have applied proximity ligation assay (PLA to detect the transcription factor SOX10 as a possible serum marker for melanoma. We studied a cohort of 110 melanoma patients. We further investigated a second cohort of 85 patients with vitiligo, which is a disease that also affects melanocytes.The specificity of the SOX10 assay in serum was high, with only 1% of healthy blood donors being positive. In contrast, elevated serum SOX10 was found with high frequency among vitiligo and melanoma patients. In patients with metastases, lack of SOX10 detection was associated with treatment benefit. In two responding patients, a change from SOX10 positivity to undetectable levels was seen before the response was evident clinically.We show for the first time that SOX10 represents a promising new serum melanoma marker for detection of early stage disease, complementing the established S100B marker. Our findings imply that SOX10 can be used to monitor responses to treatment and to assess if the treatment is of benefit at stages earlier than what is possible radiologically.

  15. Serum neutralization as a differential serological test for classical swine fever virus and other pestivirus infections

    Directory of Open Access Journals (Sweden)

    Paredes J.C.M.

    1999-01-01

    Full Text Available Serum neutralization tests (SN were performed against classical swine fever virus (CSFV, bovine viral diarrhea virus (BVDV and border disease virus (BDV on samples of swine serum collected for screening of antibodies to CSFV, in order to determine the SN value as a differential serological test. Ninety-nine sera out of a sample of 16,664 were positive for antibodies to pestiviruses in an ELISA test which did not distinguish antibodies to different pestiviruses. When submitted to SN, 81 sera were positive for CSFV antibodies only. In 17 sera, crossreactive antibodies to either CSFV, BVDV or BDV were detected. In most of these sera (13 out of 17 the differences between SN titres against the three viruses were not sufficient to estimate which was the most likely antibody-inducing virus. It was concluded that, for the SN to be useful in such differentiation, it is essential to examine a sample which must include a representative number of sera from the same farm where suspect animals were detected. When isolated serum samples are examined, such as those obtained with the sampling strategy adopted here, the SN may give rise to inconclusive results.

  16. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  17. Optimization of a colorimetric assay for glycosylated human serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Bohney, J.P.; Feldhoff, R.C.

    1986-05-01

    The thiobarbituric acid (TBA) assay has been used for several years to quantitate the amount of glucose which has been non-enzymatically linked to hemoglobin and other proteins. The ketoamine-protein adduct is converted to 5-hydroxymethylfurfural (HMF) by mild hydrolysis with oxalic acid. Reaction of HMF with TBA yields a colored product which has an absorbance maximum at 443 nm. Several modifications of the original procedure has been published, but none permit the unambiguous quantitation of glycosylated human serum albumin (glc-HSA). Problems relate to reagent preparation and stability, the time and temperature of hydrolysis, the choice of standards, and background color corrections. The authors have found that maximum color yield occurs after hydrolysis in an autoclave for 2 h. This increases the sensitivity 3-fold and cuts the assay time in half relative to hydrolysis for 4.5 h at 100/sup 0/C. A NaBH/sub 4/ reduction of a parallel protein sample must be performed to correct for variable background color associated with different sample sources and amounts. HMF can be used as a standard, however, corrections must be made for HMF degradation. Fructose is a better standard, but HMF formation from fructose is faster than formation from glc-HSA. This may result in an underestimate of percent glycosylation. The best standard appears to be glc-HSA prepared with (/sup 3/H)glucose. It appears that with proper controls and standards the TBA assay can be used to determine actual rather than relative percent glycosylation.

  18. Comparison of Brucella immunoglobulin M and G flow assays with serum agglutination and 2-mercaptoethanol tests in the diagnosis of brucellosis

    NARCIS (Netherlands)

    Zeytinoğlu, Ayşin; Turhan, Ajda; Altuğlu, Imre; Bilgiç, Altinay; Abdoel, Theresia H.; Smits, Henk L.

    2006-01-01

    The diagnostic value of Brucella IgM/IgG flow assays was evaluated in comparison with serum agglutination and 2-mercaptoethanol tests by testing a selection of serum samples submitted to the laboratory because of clinical suspicion of brucellosis. All 39 admission and 11 follow-up samples that

  19. Validation of a serum neutralization test for detection of antibodies specific to cyprinid herpesvirus 3 in infected common and koi carp (Cyprinus carpio).

    Science.gov (United States)

    Cabon, J; Louboutin, L; Castric, J; Bergmann, S; Bovo, G; Matras, M; Haenen, O; Olesen, N J; Morin, T

    2017-05-01

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of a serious infective, notifiable disease affecting common carp and varieties. In survivors, infection is generally characterized by a subclinical latency phase with restricted viral replication. The CyHV-3 genome is difficult to detect in such carrier fish that represent a potential source of dissemination if viral reactivation occurs. In this study, the analytical and diagnostic performance of an alternative serum neutralization (SN) method based on the detection of CyHV-3-specific antibodies was assessed using 151 serum or plasma samples from healthy and naturally or experimentally CyHV-3-infected carp. French CyHV-3 isolate 07/108b was neutralized efficiently by sera from carp infected with European, American and Taiwanese CyHV-3 isolates, but no neutralization was observed using sera specific to other aquatic herpesviruses. Diagnostic sensitivity, diagnostic specificity and repeatability of 95.9%, 99.0% and 99.3%, respectively, were obtained, as well as a compliance rate of 89.9% in reproducibility testing. Neutralizing antibodies were steadily detected in infected carp subjected to restrictive or permissive temperature variations over more than 25 months post-infection. The results suggest that this non-lethal diagnostic test could be used in the future to improve the epidemiological surveillance and control of CyHV-3 disease. © 2016 John Wiley & Sons Ltd.

  20. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  1. A urine midmolecule osteocalcin assay shows higher discriminatory power than a serum midmolecule osteocalcin assay during short-term alendronate treatment of osteoporotic patients.

    Science.gov (United States)

    Srivastava, A K; Mohan, S; Singer, F R; Baylink, D J

    2002-07-01

    We isolated and characterized a peptide fragment corresponding to amino acid sequence 14-28 of human osteocalcin in urine from Paget's disease, and developed a polyclonal antibody reactive to this peptide in urine. We used this antibody to measure urinary fragments of osteocalcin and compared to efficacy of the urinary osteocalcin assay with a serum osteocalcin (sOC) assay (ELISA-Osteo, Cis-Bio International) to monitor the short-term changes in bone turnover in response to alendronate treatment. The synthetic peptide-based urinary osteocalcin (uOC) radioimmunoassay (RIA) showed an analytical sensitivity of 6.25 ng/mL, standard curve range of 3.12-400 ng/mL, and mean intra- (n = 20) and interassay (n = 30) coefficient of variation (CV) of sALP) (Alkphose-B, Metra Biosystems) in serum samples. The percent change data obtained between baseline and 30 days (n = 18) posttreatment suggested a rapid decline in uOC concentration (-27%, p sALP (-3.4%, p = 0.689), two specific markers of bone formation. As expected, due to the coupling of bone formation and bone resorption, the concentration of all markers showed a 30%-45% decline compared with baseline values after 90 days (n = 16) of treatment. Correlation of markers after a 30 day treatment with alendronate revealed a higher correlation (r = 0.61, p sALP (r = -0.14, p = 0.295) with uNTx. Similarly, correlation coefficients with r values between 0.48 and 0.55 (p < 0.05) were observed between uOC, sNTx, and sCTx, whereas no significant correlation was observed between sOC and sNTx or sCTx. These results provide indirect evidence that fragments measured by the urine assay probably originated from bone resorption, and suggest that the uOC assay could be used to assess short-term changes in bone metabolism with regard to osteocalcin.

  2. The Attainment of High Sensitivity and Precision in Radioimmunoassay Techniques as Exemplified in a Simple Assay of Serum Insulin

    Energy Technology Data Exchange (ETDEWEB)

    Albano, Janet; Ekins, R. P. [Institute of Nuclear Medicine, Middlesex Hospital Medical School, London (United Kingdom)

    1970-02-15

    Recent controversy has underlined the fundamental confusion surrounding the concepts of assay ''sensitivity'' and ''precision'' and, in particular, their optimization in radioimmunoassay and other saturation assay procedures. Many formal definitions of sensitivity (e.g. that laid down by the American Chemical Society) express this concept in terms of the slope of the ''dose'' response curve; nevertheless, in common usage, the term is normally regarded as a synonym for the detection limit of the measurement technique. However, a technique which is ''sensitive'' in the formal sense may not display a low limit of detection, and it is readily demonstrable that, in radioimmunoassay systems in particular, there are circumstances in which increase in the slope of the response curve may lead to an increase in the detection limit of the assay. The authors have based their insulin assay protocols on mathematical principles specifically designed to lead to the minimization of the detection limit. The method depends on the use of (uncoated) charcoal for the separation of free and bound labelled insulin in incubation mixtures in which insulin-free human serum is used as diluent. The detection limit of the method is approximately 1 pg/ml of incubation mixture, corresponding to roughly 0.25 {mu}U/ml of serum at the serum dilutions used. In a formal comparative study, the method has been shown to be more sensitive, precise and accurate than other methods relying on double antibody or chromato-electrophoietic separation. The relevance of such factors as high specific activity labelled hormone to the attainment of high sensitivity is discussed. (author)

  3. Humoral response and neutralization capacity of sheep serum inoculated with natural and Cobalt 60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2002-01-01

    The aim of this work was to investigate antigen irradiation on crotalic antivenom and the capacity of sheep as serum producers. Twelve sheep in two groups of six were inoculated with Crotalus durissus terrificus venom. One group was inoculated with natural venom (N V) and the other with Cobalt 60 gamma-irradiated venom (Ir V). Three antigen doses were given to the animals at monthly intervals for immunization. The toxic activity of the venom was assessed by LD 50 determination in mice. Blood samples were collected weekly analyses of serum neutralization capacity and potency. At the end of the experiment, the animals were challenged with a LD 50 for sheep showed no signs of envenoming. These results showed that toxicity of the irradiated venom was 4.4 times less than the natural venom. The sera from the irradiated group neutralized LD 50 14.6 times, and the sera from the natural group 4.4 times. Sera from the irradiated group were five times more potent. The two groups did not present clinical alterations. The results of this study show the potential for using sheep in crotalic antivenom production. The use of irradiated venom in sheep immunization induces a powerful and lasting humoral immune response shown by both the in vitro neutralization and potency tests and by the indirect ELISA antibody level detection technique. (author)

  4. Recommendations for the validation of cell-based assays used for the detection of neutralizing antibody immune responses elicited against biological therapeutics.

    Science.gov (United States)

    Gupta, Shalini; Devanarayan, Viswanath; Finco, Deborah; Gunn, George R; Kirshner, Susan; Richards, Susan; Rup, Bonita; Song, An; Subramanyam, Meena

    2011-07-15

    The administration of biological therapeutics may result in the development of anti-drug antibodies (ADAs) in treated subjects. In some cases, ADA responses may result in the loss of therapeutic efficacy due to the formation of neutralizing ADAs (NAbs). An important characteristic of anti-drug NAbs is their direct inhibitory effect on the pharmacological activity of the therapeutic. Neutralizing antibody responses are of particular concern for biologic products with an endogenous homolog whose activity can be potentially dampened or completely inhibited by the NAbs leading to an autoimmune-type deficiency syndrome. Therefore, it is important that ADAs are detected and characterized appropriately using sensitive and reliable methods. The design, development and optimization of cell-based assays used for detection of NAbs have been published previously by Gupta et al. 2007 [1]. This paper provides recommendations on best practices for the validation of cell-based NAb assay and suggested validation parameters based on the experience of the authors. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. The need for a sufficient number of low level sera in comparisons of different serum vitamin B12 assays

    International Nuclear Information System (INIS)

    Gijzen, A.H.J.; Kock, H.W. de; Meulendijk, P.N.; Schmidt, N.A.; Schopman, W.; Tertoolen, J.F.W.; Voogd, C.E.

    1983-01-01

    Eight radiochemical methods for the assay of vitamin B 12 in serum were compared with the microbiological assay with Lactobacillus leichmannii ATCC 7830 using 198 individual sera of patients. There was a good agreement between the results of most samples with some kits and the microbiological assay. However, especially in the sera of vitamin B 12 -deficient patients large discrepancies between the results could occur. These variations were due to both the kits used and the performance of the assays in different laboratories. A sufficient number of non-pooled sera of vitamin B 12 -deficient patients should be included in investigations to validate radiochemical methods. (Auth.)

  6. Characterization of broadly neutralizing antibody responses to HIV-1 in a cohort of long term non-progressors.

    Science.gov (United States)

    González, Nuria; McKee, Krisha; Lynch, Rebecca M; Georgiev, Ivelin S; Jimenez, Laura; Grau, Eulalia; Yuste, Eloísa; Kwong, Peter D; Mascola, John R; Alcamí, José

    2018-01-01

    Only a small fraction of HIV-1-infected patients develop broadly neutralizing antibodies (bNAbs), a process generally associated to chronic antigen stimulation. It has been described that rare aviremic HIV-1-infected patients can generate bNAbs but this issue remains controversial. To address this matter we have assessed bNAb responses in a large cohort of long-term non-progressors (LTNPs) with low or undetectable viremia. Samples from the LTNP cohort of the Spanish AIDS Research Network (87 elite and 42 viremic controllers) and a control population of 176 viremic typical-progressors (TPs) were screened for bNAbs using Env-recombinant viruses. bNAb specificities were studied by ELISA using mutated gp120, neutralization assays with mutated viruses, and peptide competition. Epitope specificities were also elucidated from the serum pattern of neutralization against a panel of diverse HIV-1 isolates. Broadly neutralizing sera were found among 9.3% LTNPs, both elite (7%) and viremic controllers (14%). Within the broadly neutralizing sera, CD4 binding site antibodies were detected by ELISA in 4/12 LTNPs (33%), and 16/33 of TPs (48%). Anti-MPER antibodies were detected in 6/12 LTNPs (50%) and 14/33 TPs (42%) whereas glycan-dependent HIV-1 bNAbs were more frequent in LTNPs (11/12, 92%) as compared to TPs (12/33, 36%). A good concordance between standard serum mapping and neutralization-based mapping was observed. LTNPs, both viremic and elite controllers, showed broad humoral immune responses against HIV-1, including activity against many major epitopes involved in bNAbs-mediated protection.

  7. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  8. Time-resolved immunofluorometric assay of serum ferritin

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yao [China Inst. of Atomic Energy, Beijing (China)

    2007-06-15

    This assay is a solid phase, two-site fluoroimmunometric assay based on the direct sandwish technique. Standards or samples containing ferritin are first reacted with immobilized anti-ferritin antibodies. Then the europium-lablled antibodies are reacted with the bound antigen. The range of this assay is 2-1000 ng/mL. The analytical sentivity is better than 0.05 ng/mL. The intra-assay variation and inter-assay variation are both below 5%; This kit was compared with Wallac DELFIA kit. The correlation is r=0.96. (authors)

  9. Application of human erythrocytes to a radioimmune assay of immune complexes in serum. [Lupus erythematosus, type B hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, F; Miyakawa, Y; Mayumi, M [Tokyo Metropolitan Lab. of Public Health (Japan)

    1979-07-01

    An immune adherence receptor exists on the surface of primate erythrocytes, and has been characterized as a receptor for the activated third component of complement (C3b). Human red blood cells (RCBs, blood group O) were applied to a sensitive determination of complement-fixing, soluble immune complexes in serum. The method involved the binding of immune complexes with RBCs in the presence of complement and the detection of cell-bound IgG molecules by radiolabelled anti-human IgG antibodies. Since the binding of RBCs with monomeric IgG was minimal, cell bound IgG molecules were taken as representing immune complexes. When aggregated human gammaglobulin (AHG) was used as a model of immune complexes, as little as 5 ..mu..g dissolved in 1 ml of normal human serum were detected. The binding of RBCs with AHG was inhibited in EDTA solution where the classical complement pathway could not be activated. The RBC radioimmune assay was successfully applied to the determination of soluble immune complexes in pathological serum samples obtained from the patients with systemic lupus erythematosus and those with fulminant Type B hepatitis. False-positive results by autoantibodies against RBCs could be excluded by a Coombs test and by comparing the binding in the presence of complement with that in EDTA solution. The ubiquitous availability of RBCs coupled with a high sensitivity would allow the RBC radioimmune assay to be used as a further method of determining immune complexes in the serum.

  10. Performance characteristics of SCC radioimmunoassay and clinical significance serum SCC Ag assay in patients with malignancy

    International Nuclear Information System (INIS)

    Kim, Dong Youn

    1986-01-01

    To evaluate the performance characteristics of SCC RIV and the clinical significance of serum SCC Ag assay in patients with malignancy, serum SCC Ag levels were measured by SCC RIV kit in 40 normal controls and 35 percents with various untreated malignancy, who visited Chonju Presbyterian Medical Center. The results were as follows; 1. The SCC RIA was simple to perform and can be completed in two workday. And the standard curve and reproducibility were both good. 2. The mean serum SCC Ag level in normal controls was 1.64 ± 0.93 ng/mL and normal upper limit of serum SCC Ag was defined as 2.6 ng/mL. 3 out of 40 (7.5%) normal controls showed elevated SCC Ag levels above the normal upper limit. 3. In 35 patients with various untreated malignancy, 18 patients (51.4%) showed elevated serum SCC Ag levels, 59.1% of 22 patients with cervical cancer, 80% of 5 patients with lung cancer, 33% of 3 patients with esophageal cancer, 0% of 2 patients with rectal cancer and 0% of 3 patients with breast cancer showed elevated serum SCC Ag levels. Above results represent that SCC RIV is simple method to perform followed by good standard curve and reproducibility, and may be a useful indicator reflecting diagnostic data of patients with cervical cancer and lung cancer

  11. Comparison of assays for the detection of West Nile virus antibodies in equine serum after natural infection or vaccination

    Czech Academy of Sciences Publication Activity Database

    Joó, K.; Bakonyi, T.; Szenci, O.; Ferenczi, E.; Barna, M.; Malik, P.; Hubálek, Zdeněk; Fehér, O.; Kutasi, O.

    2017-01-01

    Roč. 183, č. 1 (2017), s. 1-6 ISSN 0165-2427 Institutional support: RVO:68081766 Keywords : West Nile virus * Haemagglutination-inhibition test * Enzymelinked immunosorbent assay * Plaque reduction neutralization test * Vaccination * Natural infection Subject RIV: FN - Epidemiology, Contagious Diseases ; Clinical Immunology OBOR OECD: Immunology Impact factor: 1.718, year: 2016

  12. Molecular epidemiology of malaria in Cameroon. XV. Experimental studies on serum substitutes and supplements and alternative culture media for in vitro drug sensitivity assays using fresh isolates of Plasmodium falciparum.

    Science.gov (United States)

    Basco, Leonardo K

    2003-08-01

    In vitro drug sensitivity assay is an important tool for various on-going studies aiming to establish the correlation between candidate molecular markers for drug resistance and drug response in laboratory-adapted strains and field isolates of Plasmodium falciparum. A widespread use of this technique in the field would require a suitable substitute that can replace human serum. In this study, several alternative sources of serum substitutes and supplements were evaluated for their capacity to sustain parasite growth for a single life cycle and their compatibility with in vitro assays for clinical isolates that have not been adapted to in vitro culture. Albumax, a commercial preparation of lipid-enriched bovine albumin, did not support parasite growth as much as human serum and fetal calf serum in several isolates. Other serum supplements (AmnioMax and Ultroser) supported parasite growth relatively well. The 50% inhibitory concentrations (IC50s) of chloroquine and antifolates determined with 0.05% Albumax were generally two or three times higher than with human serum. With 10% fetal calf serum, IC50s for chloroquine and antifolates were approximately two times higher and three times lower than with human serum, respectively. The use of AmnioMax and OptiMAb resulted in a greater than two-fold increase in IC50s and several uninterpretable assays. Despite possible batch-to-batch differences, fetal calf serum may be a suitable substitute for in vitro drug assays while awaiting the results of further studies on other serum substitutes and supplements.

  13. Comparison of radioassay and microbiological assay for serum folate, with clinical assessment of discrepant results

    International Nuclear Information System (INIS)

    Baril, L.; Carmel, R.

    1978-01-01

    Folate assays by use of radiolabeled folate provide obvious practical advantages over the standard microbiological assay, but remain incompletely tested. We therefore compared results for 415 sera with a kit involving 3 H-labeled folate and the Lactobacillus casei microbiological method. We examined the patients' data when there were discrepancies between the two methods. Although the correlation overall was satisfactory, results were discrepant in 25% of cases. In 74% of the latter, the radioassay result appeared to be the correct one, primarily because L. casei results were suppressed by antibiotics being taken by the patient. The radioassay occasionally gave falsely high values for patients with liver disease and falsely low ones for patients who had received isotopes for scanning purposes. Several assay kits that make use of 125 I- or 75 Se-labeled folate were also tested. Although these results correlated with the results of 3 H-labeled folate assay, various problems appeared, including the possible need for serum-supernate control tubes in one kit. Answers to these and other questions and careful clinical correlation of results are needed for any folate radioassays before their adoption for routine clinical use

  14. Performance characteristics of CA 19-9 radioimmunoassay and clinical significance of serum CA 19-9 assay in patients with malignancy

    International Nuclear Information System (INIS)

    Kim, S.E.; Shong, Y.K.; Cho, B.Y.; Kim, N.K.; Koh, C.S.; Lee, M.H.; Hong, K.S.

    1985-01-01

    To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. (Author)

  15. Carbon dots based immunosorbent assay for the determination of GFAP in human serum

    Science.gov (United States)

    Ma, Yunsu; Xu, Guanhong; Wei, Fangdi; Cen, Yao; Song, Yueyue; Ma, Yujie; Xu, Xiaoman; Shi, Menglan; Sohail, Muhammad; Hu, Qin

    2018-04-01

    Glial fibrillary acidic protein (GFAP) is expressed in the central nervous system and the level of GFAP normally rises with brain injury and astroglial tumors. So, serum GFAP is used as a marker for diagnosing various types of brain damage and astroglial tumors. In this study, a new sensor based on carbon dots (CDs) linked with antibodies to specifically detect GFAP in human serum was developed. Anti-GFAP (Ab1) linked with protein A/G agarose resin (PA/G) as a capture antibody (PA/G-Ab1) and anti-GFAP (Ab2) labeled with CDs as a detection antibody (CDs-Ab2) were prepared firstly. Then the CD-linked antibody immunosorbent assay (CLAISA) method was constructed based on the sandwich conjunction reaction among PA/G-Ab1, GFAP, and CDs-Ab2. CLAISA, using the fluorescence of PA/G-Ab1-GFAP-Ab2-CDs as the direct signal, enabled the proposed immunosensor to detect GFAP sensitively with a linear range of 0.10-8.00 ng ml-1 and a detection limit of 25 pg ml-1. This method was applied to the determination of GFAP in human serum by the standard addition method, and the results showed high accuracy and precision. Considering the easy synthetic process and excellent performance of CLAISA, this method has great potential to be used to monitor GFAP in the clinic.

  16. An immunoradiometric assay for procoagulant factor VIII antigen: results in haemophilia, von Willebrand's disease and fetal plasma and serum

    International Nuclear Information System (INIS)

    Peake, I.R.; Bloom, A.L.; Giddings, J.C.; Ludlam, C.A.

    1979-01-01

    An immunoradiometric assay (IRMA) has been developed based on the inhibitor which arose in a polytransfused severe haemophiliac. The two-site IRMA measured antigens closely associated with the procoagulant parts of the factor VIII complex, which are termed FVIIIC antigens or FVIIICAG. FVIIICAG was present in normal plasma and also, at a slightly lower concentration, in normal serum. In 37 patients with haemophilia A, 36 had FVIIICAG levels of less than 10% of the normal plasma pool. In patients with von Willebrand's disease the levels of FVIIIC and FVIIICAG were in good agreement, both before and after treatment with cryoprecipitate or DDAVP. FVIIICAG was relatively stable in plasma at 37 0 C and could also be detected in cord and fetal serum. The assay is of potential value for detecting reduced levels of factor VIII, for carrier detection and for the prenatal diagnosis of haemophilia. (author)

  17. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. Seoul (Korea, Republic of)

    2011-03-15

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R{sup 2=}0.838, P<0.001). Serum HBsAg level and serum HBV DNA copies were found to be linearly related by both methods (R{sup 2=}0.067, P=0.316 by IRMA, and R{sup 2=}0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients.

  18. An enzyme-linked immunosorbent assay for the quantification of serum platelet-bindable IgG.

    Science.gov (United States)

    Howe, S E; Lynch, D M; Lynch, J M

    1984-01-01

    An enzyme-linked immunosorbent assay (ELISA) using F(ab')2 peroxidase-labeled antihuman immunoglobulin and o-phenylenediamine dihydrochloride (OPD) as a substrate was developed to measure serum platelet bindable IgG (S-PBIgG). The assay was made quantitative by standardizing the number of normal "target" platelets bound to microtiter plate wells, and by incorporating quantitated IgG standards with each microtiter plate tested to prepare a standard calibration curve. By this method, S-PBIgG for normal individuals was 3.4 +/- 1.6 fg per platelet (mean +/- 1 SD; n = 40). Increased S-PBIgG levels were detected in 36 of 40 patients with clinical autoimmune thrombocytopenia (ATP), ranging from 7.0 to 85 fg per platelet. Normal S-PBIgG levels were found in 34 of 40 patients with nonimmune thrombocytopenia. This method showed a sensitivity of 90 percent, specificity of 85 percent, and in the sample population studied, a positive predictive value of 0.86 and a negative predictive value of 0.90. This assay is highly reproducible (coefficient of variation was 6.8%) and appears useful in the evaluation of patients with suspected immune-mediated thrombocytopenia.

  19. Clinical value of assays of multiple serum tumor markers in conjunction with 18F-FDG SPECT for discriminating malignant from benign lung disorders

    International Nuclear Information System (INIS)

    Zhang Chunyan; Wang Linglong; Tu Liping; Yu Yuefang; Zhu Weijie; Cai Ao; Gao Shuxing

    2006-01-01

    Objective: To evaluate the clinical value of assays of multiple tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung disorders. Methods: A total of 62 patients with malignant and benign lung diseases un- derwent 18 F-FDG SPECT examination and tests for serum tumor markers CEA, CA50, CA199 and CA242, alone or combined. The sensitivity, specificity, accuracy of these tests were examined. Results: The sensitivity, specificity accuracy of 18 F-FDG SPECT for the diagnosis of malignant lung tumors were 85.7 (30/35), 59.3 (16/27) and 74.2(46/62) respectively, those of each of serum CEA, CA199, CA50, CA242 levels in diagnosing malignant lung tumors were 22.9(8/35), 92.6(25/27), 59.7(33/62), 14.3(5/35), 100(27/27), 51.6 (32/62), 34.3 (12/35), 85.2 (23/27), 56.5 (35/62), 28.6 (10/35), 85.2 (23/27) and 53.2 (33/62) respectively, those of assays of multiple serum tumor markers for diagnosis of malignant lung tumors were 85.7 (30/35), 85.2 (23/27) and 85.5 (53/62) respectively, those of assays of multiple tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung nodules were 88.6(31/35), 85.2(23/27) and 87.1 (54/62) respectively. Conclusion: Assays of multiple serum tumor markers in conjunction with 18 F-FDG SPECT for discriminating malignant from benign lung disorders can yield higher sensitivity, specialty and accuracy, making a significant contribution to clinical application. (authors)

  20. 25-hydroxy-Vitamin D status: limitations in comparison and clinical interpretation of serum-levels across different assay methods.

    Science.gov (United States)

    Enko, Dietmar; Fridrich, Leo; Rezanka, Erwin; Stolba, Robert; Ernst, Juliane; Wendler, Iris; Fabian, Daniel; Hauptlorenz, Susanne; Halwachs-Baumann, Gabriele

    2014-01-01

    Background: Over the last decade, clinical interest to evaluate human 25-hydroxy-vitamin D (25[OH]D) serum levels has increased exponentially. In the present study, four chemiluminescence immunoassays (CLIA), one radioimmunoassy (RIA), and one high performance liquid chromatography (HPLC) method were compared and also with the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in view of 25(OH)D serum level determination. Methods: For the method comparison, blood samples from 133 consecutive patients were prospectively collected. All participants gave written informed consent for their blood samples to be used in this study. They came to the Department of Nuclear Medicine of the Central Hospital Steyr (Austria) for osteodensidometric measurement as part of their preventive medical check-up. Pearson's correlation coefficients, Bland-Altman plots, and paired t-tests were calculated. Assay-specific reference ranges were considered using blood samples from persons with normal parathormone, calcium, and total-protein values (n = 97). Results: The highest correlation was between the HPLC and the LC-MS/MS method (r = 0.96). The lowest correlation was between the cobas Vitamin D3 assay (Roche) and any of the evaluated assays (r = 0.46 - 0.63). Bland-Altman plots revealed a big negative mean bias in three assays (cobas Vitamin D3 assay [Roche]: -22.8; DiaSorin LIAISON [25[OH]D total CLIA [Diasorin]: -18.4; Diasorin 25[OH]D125 I RIA [Diasorin]: -23.8 [nmol/L]) and a much smaller positive mean bias in the other assays (ClinRep complete 25[OH]D2/D3 HPLC kit [Recipe]: 2.7; ADVIA Centaur Vitamin D total assay [Siemens]: 8.2; IDS total vitamin D assay [Immunodiagnostic Systems]: 12.1 [nmol/L]) compared to the LC-MS/MS method. Meanwhile, the manufacturer has withdrawn the cobas Vitamin D3 assay from the market. Conclusions: Poor antibody specificity with cross-reactivity to other vitamin D metabolites, incomplete extraction of the 25(OH)D analyte from the vitamin D

  1. Measles Virus Hemagglutinin epitopes immunogenic in natural infection and vaccination are targeted by broad or genotype-specific neutralizing monoclonal antibodies.

    Science.gov (United States)

    Muñoz-Alía, Miguel Angel; Casasnovas, José M; Celma, María Luisa; Carabaña, Juan; Liton, Paloma B; Fernandez-Muñoz, Rafael

    2017-05-15

    Measles virus (MV) remains a leading cause of vaccine-preventable deaths in children. Protection against MV is associated with neutralizing antibodies that preferentially recognize the viral hemagglutinin (MV-H), and to a lesser extent, the fusion protein (MV-F). Although MV is serologically monotypic, 24 genotypes have been identified. Here we report three neutralization epitopes conserved in the more prevalent circulating MV genotypes, two located in the MV-H receptor binding site (RBS) (antigenic site III) and a third in MV-H/MV-F interphase (antigenic site Ia) which are essential for MV multiplication. In contrast, two MV-H neutralization epitopes, showed a genotype-specific neutralization escape due to a single amino acid change, that we mapped in the "noose" antigenic site, or an enhanced neutralization epitope (antigenic site IIa). The monoclonal antibody (mAb) neutralization potency correlated with its binding affinity and was mainly driven by kinetic dissociation rate (k off ). We developed an immunoassay for mAb binding to MV-H in its native hetero-oligomeric structure with MV-F on the surface of a MV productive steady-state persistently infected (p.i.) human cell lines, and a competitive-binding assay with serum from individuals with past infection by different MV genotypes. Binding assays revealed that a broad neutralization epitope, in RBS antigenic site, a genotype specific neutralization epitopes, in noose and IIa sites, were immunogenic in natural infection and vaccination and may elicit long-lasting humoral immunity that might contribute to explain MV immunogenic stability. These results support the design of improved measles vaccines, broad-spectrum prophylactic or therapeutic antibodies and MV-used in oncolytic therapies. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Thermometric enzyme linked immunosorbent assay: TELISA.

    Science.gov (United States)

    Mattiasson, B; Borrebaeck, C; Sanfridson, B; Mosbach, K

    1977-08-11

    A new method, thermometric enzyme linked immunosorbent assay (TELISA), for the assay of endogenous and exogenous compounds in biological fluids is described. It is based on the previously described enzyme linked immunosorbent assay technique, ELISA, but utilizes enzymic heat formation which is measured in an enzyme thermistor unit. In the model system studied determination of human serum albumin down to a concentration of 10(-10) M (5 ng/ml) was achieved, with both normal and catalase labelled human serum albumin competing for the binding sites on the immunosorbent, which was rabbit antihuman serum albumin immobilized onto Sepharose CL-4B.

  3. Comparison of cell-based and non-cell-based assay platforms for the detection of clinically relevant anti-drug neutralizing antibodies for immunogenicity assessment of therapeutic proteins.

    Science.gov (United States)

    Hu, Jenny; Wala, Iwona; Han, Hong; Nagatani, Janice; Barger, Troy; Civoli, Francesca; Kaliyaperumal, Arunan; Zhuang, Yao; Gupta, Shalini

    2015-04-01

    Anti-drug neutralizing antibodies (NAbs) formed due to unwanted immunogenicity of a therapeutic protein point towards a mature immune response. NAb detection is important in interpreting the therapeutic's efficacy and safety in vivo. In vitro cell-based NAb assays provide a physiological system for NAb detection, however are complex assays. Non-cell-based competitive ligand binding (CLB) approaches are also employed for NAb detection. Instead of cells, CLB assays use soluble receptor and conjugated reagents and are easier to perform, however have reduced physiological relevance. The aim of this study was to compare the performance of CLB assays to established cell-based assays to determine the former's ability to detect clinically relevant NAbs towards therapeutics that (i) acted as an agonist or (ii) acted as antagonists by binding to a target receptor. We performed a head-to-head comparison of the performance of cell-based and CLB NAb assays for erythropoietin (EPO) and two anti-receptor monoclonal antibodies (AMG-X and AMG 317). Clinically relevant NAb-positive samples identified previously by a cell-based assay were assessed in the corresponding CLB format(s). A panel of 12 engineered fully human anti-EPO monoclonal antibodies (MAbs) was tested in both EPO NAb assay formats. Our results showed that the CLB format was (i) capable of detecting human anti-EPO MAbs of differing neutralizing capabilities and affinities and (ii) provided similar results as the cell-based assay for detecting NAbs in patient samples. The cell-based and CLB assays also behaved comparably in detecting NAbs in clinical samples for AMG-X. In the case of anti-AMG 317 NAbs, the CLB format failed to detect NAbs in more than 50% of the tested samples. We conclude that assay sensitivity, drug tolerance and the selected assay matrix played an important role in the inability of AMG 317 CLB assays to detect clinically relevant NAbs. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay

    NARCIS (Netherlands)

    Beld, Marcel; Sentjens, Roel; Rebers, Sjoerd; Weegink, Christine; Weel, Jan; Sol, Cees; Boom, René

    2002-01-01

    We have evaluated the VERSANT HCV RNA 3.0. Assay (HCV 3.0 bDNA assay) (Bayer Diagnostics, Berkeley, Calif.), which is an improved signal amplification procedure for the HCV 2.0 bDNA assay for the quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The HCV 3.0

  5. Development of a new in vivo kit for detection of prostate specific antigen in human serum using immunoradiometric assay method

    International Nuclear Information System (INIS)

    Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.

    2006-01-01

    Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum

  6. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R 2= 0.838, P 2= 0.067, P=0.316 by IRMA, and R 2= 0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients

  7. Clinical applications of HPLC-competitive protein binding assay for serum 25-hydroxyvitamin D

    International Nuclear Information System (INIS)

    Yang Shouli

    1989-01-01

    This report describes the clinical applications of HPLC-competitive protein binding assay for serum 25(OH) Vit D in 156 cases. Serum 25(OH) Vit D of normal human was 33.1 +- 14.8 nmol/L (13.2 +- 5.9 ng/ml), while for various diseases are as follows: rickets, 18.0 +- 9.0 nmol/L (7.2 +- 3.6 ng/ml, n = 36, P 0.1); pneumonia of children, 33.8 +- 14.8 nmol/L (13.5 +- 5.9 ng/ml, n = 10, P > 0.5); cirrhosis, 13.8 +- 11.3 nmol/L (5.5 +- 4.5 ng/ml, n = 9, P 0.2); administration of anticonvulsant (1 to 15 years), 19.0 +- 6.5 nmol/L (7.6 +- 2.6 ng/ml, n = 19, P 6 months), 15.3 +- 5.0 nmol/L (6.1 +- 2.0 ng/ml, n = 6, P 0.5); pregnant women, 39.8 +- 16.5 nmol/L (15.9 +- 6.6 ng/ml, n = 7, P > 0.1). We found it is a useful reference value for most of the above diseased state especially for differentiation between rickets and hypervitaminosis

  8. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  9. IgA and neutralizing antibodies to influenza a virus in human milk: a randomized trial of antenatal influenza immunization.

    Science.gov (United States)

    Schlaudecker, Elizabeth P; Steinhoff, Mark C; Omer, Saad B; McNeal, Monica M; Roy, Eliza; Arifeen, Shams E; Dodd, Caitlin N; Raqib, Rubhana; Breiman, Robert F; Zaman, K

    2013-01-01

    Antenatal immunization of mothers with influenza vaccine increases serum antibodies and reduces the rates of influenza illness in mothers and their infants. We report the effect of antenatal immunization on the levels of specific anti-influenza IgA levels in human breast milk. (ClinicalTrials.gov identifier NCT00142389; http://clinicaltrials.gov/ct2/show/NCT00142389). The Mother's Gift study was a prospective, blinded, randomized controlled trial that assigned 340 pregnant Bangladeshi mothers to receive either trivalent inactivated influenza vaccine, or 23-valent pneumococcal polysaccharide vaccine during the third trimester. We evaluated breast milk at birth, 6 weeks, 6 months, and 12 months, and serum at 10 weeks and 12 months. Milk and serum specimens from 57 subjects were assayed for specific IgA antibody to influenza A/New Caledonia (H1N1) using an enzyme-linked immunosorbent assay (ELISA) and a virus neutralization assay, and for total IgA using ELISA. Influenza-specific IgA levels in breast milk were significantly higher in influenza vaccinees than in pneumococcal controls for at least 6 months postpartum (p = 0.04). Geometric mean concentrations ranged from 8.0 to 91.1 ELISA units/ml in vaccinees, versus 2.3 to 13.7 ELISA units/mL in controls. Virus neutralization titers in milk were 1.2 to 3 fold greater in vaccinees, and correlated with influenza-specific IgA levels (r = 0.86). Greater exclusivity of breastfeeding in the first 6 months of life significantly decreased the expected number of respiratory illness with fever episodes in infants of influenza-vaccinated mothers (p = 0.0042) but not in infants of pneumococcal-vaccinated mothers (p = 0.4154). The sustained high levels of actively produced anti-influenza IgA in breast milk and the decreased infant episodes of respiratory illness with fever suggest that breastfeeding may provide local mucosal protection for the infant for at least 6 months. Studies are needed to determine the

  10. Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection

    International Nuclear Information System (INIS)

    Ma Caiyun; Jiang Li; Ge Gaoxia; Zhang Xiaojie

    2005-01-01

    Electrochemiluminescene immunoassay (ECLIA) and enzyme-linked immunosorbent (ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA. The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values, 4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively. The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L. Only in 3 samples, the results measured by ECLIA and ELISA were different (ECLIA: positive; ELISA: negative) among 165 samples. It is concluded that the met hod of ECLIA is more efficient than ELISA for detection of HBsAb in serum. (authors)

  11. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  12. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    Science.gov (United States)

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Effect of serum heat-inactivation and dilution on detection of anti-WNV antibodies in mice by West Nile virus E-protein microsphere immunoassay.

    Directory of Open Access Journals (Sweden)

    Madhuri Namekar

    Full Text Available Immunopathogenesis studies employing West Nile virus (WNV mice model are important for the development of antivirals and vaccines against WNV. Since antibodies produced in mice early during WNV infection are essential for clearing virus from the periphery, it is important to detect early and persistent anti-WNV antibodies. ELISA and plaque reduction neutralization tests are traditionally used for detection of anti-WNV antibodies and WNV-neutralizing antibodies, respectively. Although these assays are sensitive and specific, they are expensive and time consuming. Microsphere immunoassays (MIA are sensitive, specific, allow for high throughput, are cost effective, require less time to perform than other methods, and require low serum volumes. Several assay parameters such as serum heat-inactivation (HI and dilution can alter WNV MIA sensitivity. We examined the effect of these parameters on WNV E-protein MIA (WNV E-MIA for the enhanced detection of anti-WNV IgM and IgG antibodies. WNV E-MIA was conducted using serial dilutions of HI and non-HI (NHI serum collected at various time points from mice inoculated with WNV. HI significantly enhanced detection of IgM and IgG antibodies as compared to NHI serum. WNV IgM and IgG antibodies in HI sera were detected earlier at day 3 and IgM antibodies persisted up to day 24 after infection. HI serum at 1∶20 dilution was found to be optimal for detection of both IgM and IgG antibodies as compared to higher-serum dilutions. Further, addition of exogenous complement to the HI serum decreased the WNV E-MIA sensitivity. These results suggest that serum-HI and optimal dilution enhance WNV E-MIA sensitivity by eliminating the complement interference, thereby detecting low-titer anti-WNV antibodies during early and late phases of infection. This improved MIA can also be readily employed for detection of low-titer antibodies for detection of other infectious agents and host proteins.

  14. Development of RIA reagents for detection of serum T3 using magnetic assay method

    International Nuclear Information System (INIS)

    Prasarnleungwirai, P.; Suprarop, P.; Tanjoy, V.; Saraneeyatham, T.

    1992-01-01

    The T3 RIA assay is widely used for diagnosis of the disease caused by malfunction of thyroid organ. The common methods used are: 1. Liquid phase, second antibody and PEG. 2. Solid phase, cellulose or sepharose. Since these two techniques need expensive refrigerated centrifuges to separate the bound from free, small labs in the remote part of the countries whose budgets are limited cannot use this technique. Magnetic assay technique for T3 detection employ strong magnetic plate for separation thus eliminate the use of costly refrigerated centrifuge. Preparation of magnetizable cellulose particles conjugated to proper anti T3 serum is done by activation of selected magnetizable cellulose particle with CDI (1,1 carbonyl dimidazole). The activated magnetic particles are then coupled to specific antibody in borate buffer pH 8. The assessment of prepared magnetic particle capture anti T3 are done by selecting the proper concentration of anti T3 magnetic particles. The result from both magnetic technique and second antibody/PEG are compared, and they show good correlation

  15. Flow cytometry-based assay to evaluate human serum MUC1-Tn antibodies

    DEFF Research Database (Denmark)

    Van Elssen, Catharina H M J; Clausen, Henrik; Germeraad, Wilfred T V

    2011-01-01

    Mucin-1 (MUC1) is a heavily O-glycosylated, transmembrane protein that is expressed on the apical surface of most secretory epithelia. In malignantly transformed epithelia, MUC1 has lost its apical distribution, is underglycosylated and is secreted into the circulation. Due to the underglycosylat......Mucin-1 (MUC1) is a heavily O-glycosylated, transmembrane protein that is expressed on the apical surface of most secretory epithelia. In malignantly transformed epithelia, MUC1 has lost its apical distribution, is underglycosylated and is secreted into the circulation. Due...... to detect antibodies binding to the underglycosylated MUC1 protein. This cellular system is complementary to the previously published methods to detect MUC1 serum antibodies, since the antibodies to the native protein are evaluated and therefore it can be effectively used for MUC1 antibody monitoring...... in vaccination studies as well as for functional assays....

  16. Microbiological assay of ampicillin in serum and aqueous humor of patients given ampicillin-sulbactam injection

    Directory of Open Access Journals (Sweden)

    Madhavan Hajib

    1998-01-01

    Full Text Available The aim of this study was to determine the bacterial growth inhibitory activities of ampicillin in aqueous humor and serum of patients administered ampicillin-sulbactam combination intramuscularly prior to cataract surgery. 43 patients received a combination of both antibiotics intramuscularly at varying periods (60-140 minutes prior to surgery. Aqueous humor and venous blood were collected at the beginning of the surgery. For microbiological assay, spores of Bacillus subtilis were incorporated in the agar. The test sample and the standard solutions (calibrators of ampicillin and ampicillin-sulbactam combination were placed in 3 mm wells in the agar. The diameter zones of growth inhibitory activities of ampicillin of the calibrators and the test samples measured in mm were extrapolated to the standard curve and were recorded as ampicillin activity in (μg/ml. The results of the assay were placed in 5 groups according to the time intervals between injection and collection of serum and aqueous humor (≤70, 75, 80, 90, >90 minutes. Ampicillin activities in sera and aqueous humor of group 5 (>90 minutes were significantly higher than the others (p<0.001. The ratio of ampicillin activities of sera and aqueous humor in group 5 patients was significantly lower indicating higher concentration of ampicillin activity in aqueous humor during this period. Bacterial growth inhibitory activities of ampicillin-sulbactam combination were adequate in aqueous humor of all patients with highest activity being 90 minutes after intramuscular administration indicating the potential usefulness of this antibiotic combination as chemoprophylaxis prior to cataract surgery.

  17. International Network for Comparison of HIV Neutralization Assays: The NeutNet Report II

    NARCIS (Netherlands)

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Background: Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance,

  18. Enzyme-linked immunosorbent serum assay specific for the 7S domain of Collagen Type IV (P4NP 7S)

    DEFF Research Database (Denmark)

    Leeming, Diana J; Nielsen, Mette J; Dai, Yueqin

    2012-01-01

    Aim:  The present study describes the ability of a newly developed N-terminal pro-peptides of type IV collagen 7S domain (P4NP 7S) competitive enzyme-linked immunosorbent assay (ELISA) for describing liver fibrosis. The assay applies a monoclonal antibody specific for a PIVNP 7S epitope 100...... were significantly elevated in rat with liver fibrosis as seen by histology (CCL4: 283% elevated in the highest quartile of total hepatic collagen compared with controls, P = 0.001; BDL: 183% elevated at week 4 compared with sham, P type IV collagen...... expression in BDL rats (r = 0.49, P serum assay specific for P4NP 7S was highly related to liver fibrosis...

  19. Development of an enzyme-linked immunosorbent assay for detection of CDCP1 shed from the cell surface and present in colorectal cancer serum specimens.

    Science.gov (United States)

    Chen, Yang; Harrington, Brittney S; Lau, Kevin C N; Burke, Lez J; He, Yaowu; Iconomou, Mary; Palmer, James S; Meade, Brian; Lumley, John W; Hooper, John D

    2017-05-30

    CUB domain containing protein 1 (CDCP1) is a transmembrane protein involved in progression of several cancers. When located on the plasma membrane, full-length 135kDa CDCP1 can undergo proteolysis mediated by serine proteases that cleave after two adjacent amino acids (arginine 368 and lysine 369). This releases from the cell surface two 65kDa fragments, collectively termed ShE-CDCP1, that differ by one carboxyl terminal residue. To evaluate the function of CDCP1 and its potential utility as a cancer biomarker, in this study we developed an enzyme-linked immunosorbent assay (ELISA) to reliably and easily measure the concentration of ShE-CDCP1 in biological samples. Using a reference standard we demonstrate that the developed ELISA has a working range of 0.68-26.5ng/ml, and the limit of detection is 0.25ng/ml. It displays high intra-assay (repeatability) and high inter-assay (reproducibility) precision with all coefficients of variation ≤7%. The ELISA also displays high accuracy detecting ShE-CDCP1 levels at ≥94.8% of actual concentration using quality control samples. We employed the ELISA to measure the concentration of ShE-CDCP1 in human serum samples with our results suggesting that levels are significantly higher in serum of colorectal cancer patients compared with serum from individuals with benign conditions (pELISA is a suitable method to quantify ShE-CDCP1 concentration in human serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Actions of four organic acids in radix isatidis on endotoxin-neutralization investigated by kinetic turbidimetric assay.

    Science.gov (United States)

    Ma, Li; He, Ying-jun; Li, You; Gong, Mu-xin

    2012-06-01

    To investigate anti-endotoxin action of four OAs reacted with endotoxin by the LAL assay with KTA. Using a incubating kinetic tube reader and kinetic turbidimetric assay (KTA), the concentration-response time curve of endotoxin reacted with limulus amebocyte lysate (LAL) at 37 degrees C were obtained and the action of four organic acids (OAs) on it were investigated. The four OAs were benzoic acid, salicylic acid, syringic acid and 2-amino-benzoic acid from Radix isatidis. Meanwhile, the temperature variation caused by endotoxin with the four OAs was studied by the rabbit pyrogen test (RPT). It was showed that a low concentration (1 mg/mL) of the four OAs had a little effect of anti-endotoxin, and when the concentrations of the four OAs were 30 mg/mL, the endotoxin was neutralized completely. The relationships between the concentrations of endotoxin and the OAs were all linear with correlation coefficients of greater than 0.9995, indicating that the four OAs all had strong anti-endotoxin action, while syringic acid had the strongest action among the four OAs with IC50 of 12.84 mg/mL. The investigations of KTA agreed well with the results obtained by means of RPT.

  1. Optimization of Neutral Comet Assay for studying DNA double-strand breaks in pea and wheat

    Directory of Open Access Journals (Sweden)

    Ivelina Nikolova

    2013-01-01

    Full Text Available This study describes an adaptation of the Comet assay under neutral conditions for mono- and dicotyledonous plants pea (Pisum sativum L. and wheat (Triticum aestivum L.. Modifications concern lysis and electrophoresis steps, respectively. Electrophoresis was carried out varying the intensity of the electric field. A linear relationship between the percentages of DNA in the tail from control background with alteration of intensity was found. Trypan blue dye exclusion test was used in order to determine the intactness of nuclear membrane of the isolated nuclei from both plant model systems. Assessment was conducted on non-irradiated and irradiated nuclei on a monolayer with three doses of UVC. It was found that the share of intact nuclei (trypan blue negative ones is about 95% in controls. Gradual dose-related increase of damaged nuclei was observed in both species, reaching statistical significance only at the higher dose applied.

  2. A biotin-drug extraction and acid dissociation (BEAD) procedure to eliminate matrix and drug interference in a protein complex anti-drug antibody (ADA) isotype specific assay.

    Science.gov (United States)

    Niu, Hongmei; Klem, Thomas; Yang, Jinsong; Qiu, Yongchang; Pan, Luying

    2017-07-01

    Monitoring anti-drug antibody (ADA) responses in patients receiving protein therapeutics treatment is an important safety assessment for regulatory agencies, drug manufacturers, clinicians and patients. Recombinant human IGF-1/IGFBP-3 (rhIGF-1/rhIGFBP-3) is a 1:1 formulation of naturally occurring protein complex. The individual IGF-1 and IGFBP-3 proteins have multiple binding partners in serum matrix with high binding affinity to each other, which presents challenges in ADA assay development. We have developed a biotin-drug extraction with acid dissociation (BEAD) procedure followed by an electrochemiluminescence (ECL) direct assay to overcome matrix and drug interference. The method utilizes two step acid dissociation and excess biotin-drug to extract total ADA, which are further captured by soluble biotin-drug and detected in an ECL semi-homogeneous direct assay format. The pre-treatment method effectively eliminates interference by serum matrix and free drug, and enhances assay sensitivity. The assays passed acceptance criteria for all validation parameters, and have been used for clinical sample Ab testing. This method principle exemplifies a new approach for anti-isotype ADA assays, and could be an effective strategy for neutralizing antibody (NAb), pharmacokinetic (PK) and biomarker analysis in need of overcoming interference factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  4. The comparison between the humoral response and the neutralizing capacity of sheep serum inoculated with natural venom and Co60 irradiated venom from Crotalus durissus terrificus (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.

    2000-01-01

    Crotalus durissus terrificus venom was irradiated with Co 60 to investigate the effects of antigen-irradiation on antivenom production in sheep. Twelve sheep were divided in two groups of 6. One group received irradiated, while the other received natural venom. Three doses of antigen were given at monthly intervals. The toxic activity of the venom was assessed by LD 50 in mice. Weekly blood samples were obtained to evaluate anti-crotalic serum titers by indirect ELISA, neutralization capacity, and serum potency. A complete blood count, plasma protein and fibrinogen concentration, and serum albumin and globulin were also determined. At end of the experiment, the animals were challenged with ovine LD 50 , without clinical abnormalities. (author)

  5. Radioimmunoassay for determination of thyroglobulin in human serum

    International Nuclear Information System (INIS)

    Rodriguez Cabrera, M.E.; Blanca Fernandez, S.; Baldor Navarro, F.; Rodriguez Gonzalez, J.C.

    1996-01-01

    We described the development and analytical evaluation of a radioimmunoassay with double antibody in liquid phase for human serum thyroglobulin determination using a set of reagents produced in the National Institute of Endocrinology. The reference interval for normal population was 5.7 - 44 ng/ml (X± 2DS; n=170). The intra-assay precipision was 8.1 % (control serum A) and 7.0 (control serum B) and the inter-assay precision was 9.1 % (control serum A) and 9.2 % (control serum B). The sensibility was 4.7 ng/ml and the recovery was 95 %

  6. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  7. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  8. INDUCTION OF CYTOKINE PRODUCTION IN CHEETAH (ACINONYX JUBATUS) PERIPHERAL BLOOD MONONUCLEAR CELLS AND VALIDATION OF FELINE-SPECIFIC CYTOKINE ASSAYS FOR ANALYSIS OF CHEETAH SERUM.

    Science.gov (United States)

    Franklin, Ashley D; Crosier, Adrienne E; Vansandt, Lindsey M; Mattson, Elliot; Xiao, Zhengguo

    2015-06-01

    Peripheral blood mononuclear cells (PBMCs) were isolated from the whole blood of cheetahs (Acinonyx jubatus ; n=3) and stimulated with lipopolysaccharides (LPS) to induce the production of proinflammatory cytokines TNF-α, IL-1β, and IL-6 for establishment of cross-reactivity between these cheetah cytokines and feline-specific cytokine antibodies provided in commercially available Feline DuoSet® ELISA kits (R&D Systems, Inc., Minneapolis, Minnesota 55413, USA). This study found that feline-specific cytokine antibodies bind specifically to cheetah proinflammatory cytokines TNF-α, IL-1β, and IL-6 from cell culture supernatants. The assays also revealed that cheetah PBMCs produce a measurable, cell concentration-dependent increase in proinflammatory cytokine production after LPS stimulation. To enable the use of these kits, which are designed for cell culture supernatants for analyzing cytokine concentrations in cheetah serum, percent recovery and parallelism of feline cytokine standards in cheetah serum were also evaluated. Cytokine concentrations in cheetah serum were approximated based on the use of domestic cat standards in the absence of cheetah standard material. In all cases (for cytokines TNF-α, IL-1β, and IL-6), percent recovery increased as the serum sample dilution increased, though percent recovery varied between cytokines at a given dilution factor. A 1:2 dilution of serum resulted in approximately 45, 82, and 7% recovery of TNF-α, IL-1β, and IL-6 standards, respectively. Adequate parallelism was observed across a large range of cytokine concentrations for TNF-α and IL-1β; however, a significant departure from parallelism was observed between the IL-6 standard and the serum samples (P=0.004). Therefore, based on our results, the Feline DuoSet ELISA (R&D Systems, Inc.) kits are valid assays for the measurement of TNF-α and IL-1β in cheetah serum but should not be used for accurate measurement of IL-6.

  9. Analysis of serum angiotensin-converting enzyme.

    Science.gov (United States)

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  10. Broadly Neutralizing Activity of Zika Virus-Immune Sera Identifies a Single Viral Serotype

    Directory of Open Access Journals (Sweden)

    Kimberly A. Dowd

    2016-08-01

    Full Text Available Recent epidemics of Zika virus (ZIKV have been associated with congenital malformation during pregnancy and Guillain-Barré syndrome. There are two ZIKV lineages (African and Asian that share >95% amino acid identity. Little is known regarding the ability of neutralizing antibodies elicited against one lineage to protect against the other. We investigated the breadth of the neutralizing antibody response following ZIKV infection by measuring the sensitivity of six ZIKV strains to neutralization by ZIKV-confirmed convalescent human serum or plasma samples. Contemporary Asian and early African ZIKV strains were similarly sensitive to neutralization regardless of the cellular source of virus. Furthermore, mouse immune serum generated after infection with African or Asian ZIKV strains was capable of neutralizing homologous and heterologous ZIKV strains equivalently. Because our study only defines a single ZIKV serotype, vaccine candidates eliciting robust neutralizing antibody responses should inhibit infection of both ZIKV lineages, including strains circulating in the Americas.

  11. Cross-neutralization between three mumps viruses & mapping of haemagglutinin-neuraminidase (HN epitopes

    Directory of Open Access Journals (Sweden)

    Sunil R Vaidya

    2016-01-01

    Full Text Available Background & objectives: The reports from the countries where mumps vaccine is given as routine immunization suggest differences in mumps virus neutralizing antibody titres when tested with vaccine and wild type viruses. Such reports are unavailable from countries like India where mumps vaccine is not included in routine immunization. We, therefore, undertook this study to understand the cross-neutralization activity of Indian mumps viruses. Methods: By using commercial mumps IgG enzyme immunoassay (EIA and a rapid focus reduction neutralization test (FRNT, a panel of serum samples was tested. The panel consisted of 14 acute and 14 convalescent serum samples collected during a mumps outbreak and 18 archived serum samples. Two wild types (genotypes C and G and Leningrad-Zagreb vaccine strain (genotype N were used for the challenge experiments and FRNT titres were determined and further compared. The HN protein sequence of three mumps viruses was analyzed for the presence of key epitopes. Results: All serum samples effectively neutralized mumps virus wild types and a vaccine strain. However, significantly lower FRNT titres were noted to wild types than to vaccine strain (P<0.05. The comparison between EIA and FRNT results revealed 95.6 per cent agreement. No amino acid changes were seen in the epitopes in the Indian wild type strains. All potential N-linked glycosylation sites were observed in Indian strains. Interpretation & conclusions:Good cross-neutralization activity was observed for three mumps virus strains, however, higher level of FRNT titres was detected for mumps virus vaccine strain compared to Indian wild type isolates.

  12. Cross-neutralization between three mumps viruses & mapping of haemagglutinin-neuraminidase (HN) epitopes.

    Science.gov (United States)

    Vaidya, Sunil R; Dvivedi, Garima M; Jadhav, Santoshkumar M

    2016-01-01

    The reports from the countries where mumps vaccine is given as routine immunization suggest differences in mumps virus neutralizing antibody titres when tested with vaccine and wild type viruses. Such reports are unavailable from countries like India where mumps vaccine is not included in routine immunization. We, therefore, undertook this study to understand the cross-neutralization activity of Indian mumps viruses. By using commercial mumps IgG enzyme immunoassay (EIA) and a rapid focus reduction neutralization test (FRNT), a panel of serum samples was tested. The panel consisted of 14 acute and 14 convalescent serum samples collected during a mumps outbreak and 18 archived serum samples. Two wild types (genotypes C and G) and Leningrad-Zagreb vaccine strain (genotype N) were used for the challenge experiments and FRNT titres were determined and further compared. The HN protein sequence of three mumps viruses was analyzed for the presence of key epitopes. All serum samples effectively neutralized mumps virus wild types and a vaccine strain. However, significantly lower FRNT titres were noted to wild types than to vaccine strain (P<0.05). The comparison between EIA and FRNT results revealed 95.6 per cent agreement. No amino acid changes were seen in the epitopes in the Indian wild type strains. All potential N-linked glycosylation sites were observed in Indian strains. Good cross-neutralization activity was observed for three mumps virus strains, however, higher level of FRNT titres was detected for mumps virus vaccine strain compared to Indian wild type isolates.

  13. Fluorescence Adherence Inhibition Assay: A Novel Functional Assessment of Blocking Virus Attachment by Vaccine-Induced Antibodies.

    Directory of Open Access Journals (Sweden)

    Atul Asati

    Full Text Available Neutralizing antibodies induced by vaccination or natural infection play a critically important role in protection against the viral diseases. In general, neutralization of the viral infection occurs via two major pathways: pre- and post-attachment modes, the first being the most important for such infections as influenza and polio, the latter being significant for filoviruses. Neutralizing capacity of antibodies is typically evaluated by virus neutralization assays that assess reduction of viral infectivity to the target cells in the presence of functional antibodies. Plaque reduction neutralization test, microneutralization and immunofluorescent assays are often used as gold standard virus neutralization assays. However, these methods are associated with several important prerequisites such as use of live virus requiring safety precautions, tedious evaluation procedure and long assessment time. Hence, there is a need for a robust, inexpensive high throughput functional assay that can be performed rapidly using inactivated virus, without extensive safety precautions. Herein, we report a novel high throughput Fluorescence Adherence Inhibition assay (fADI using inactivated virus labeled with fluorescent secondary antibodies virus and Vero cells or erythrocytes as targets. It requires only few hours to assess pre-attachment neutralizing capacity of donor sera. fADI assay was tested successfully on donors immunized with polio, yellow fever and influenza vaccines. To further simplify and improve the throughput of the assay, we have developed a mathematical approach for calculating the 50% titers from a single sample dilution, without the need to analyze multi-point titration curves. Assessment of pre- and post-vaccination human sera from subjects immunized with IPOL®, YF-VAX® and 2013-2014 Fluzone® vaccines demonstrated high efficiency of the assay. The results correlated very well with microneutralization assay performed independently by the FDA

  14. Novel cell-based assay reveals associations of circulating serum AhR-ligands with metabolic syndrome and mitochondrial dysfunction.

    Science.gov (United States)

    Park, Wook-Ha; Jun, Dae Won; Kim, Jin Taek; Jeong, Jae Hoon; Park, Hyokeun; Chang, Yoon-Seok; Park, Kyong Soo; Lee, Hong Kyu; Pak, Youngmi Kim

    2013-01-01

    Serum concentrations of environmental pollutants have been positively correlated with diabetes and metabolic syndrome in epidemiologic studies. In turn, abnormal mitochondrial function has been associated with the diseases. The relationships between these variables, however, have not been studied. We developed novel cell-based aryl hydrocarbon receptor (AhR) agonist bioassay system without solvent extraction process and analyzed whether low-dose circulating AhR ligands in human serum are associated with parameters of metabolic syndrome and mitochondrial function. Serum AhR ligand activities were measured as serum 2,3,7,8-tetrachlorodibenzo-p-dioxin equivalent (sTCDDeq) in pM using 10 μL human sera from 97 Korean participants (47 with glucose intolerance and 50 matched controls, average age of 46.6 ± 9.9 years, 53 male and 45 female). sTCDDeq were higher in participants with glucose intolerance than normal controls and were positively associated (P fasting glucose, but not with HDL-cholesterol. Body mass index was in a positive linear relationship with serum AhR ligands in healthy participants. When myoblast cells were incubated with human sera, ATP generating power of mitochondria became impaired in an AhR ligand concentration-dependent manner. Our results support that circulating AhR ligands may directly reduce mitochondrial function in tissues, leading to weight gain, glucose intolerance, and metabolic syndrome. Our rapid cell-based assay using minute volume of human serum may provide one of the best monitoring systems for circulating AhR ligands, good clinical biomarkers for the progress of disease and therapeutic efficacy. Copyright © 2013 International Union of Biochemistry and Molecular Biology, Inc.

  15. Physiological and endocrino-metabolic factors affecting serum myoglobin levels assayed by a radioimmunological method

    International Nuclear Information System (INIS)

    Clerico, A.; Giampietro, O.; Del Chicca, M.G.

    1984-01-01

    Only recently with the introduction of accurate and sensitive RIA methods it has been possible to detect significant amounts of myoglobin (M) in human sera. We studied serum M levels by a RIA in normal subjects and athletes with different age, sex and muscle mass, at rest and in different hours of the day, and after physical training, in hypothyroid and acromegalic patients before and after therapy, with the aim to evidentiate the possible factors affecting serum M levels. We used for M assay a very sensitive RIA method. We studied 62 normal adult persons (32 men and 30 women, 16-62 years of age), 93 children (0-12 year old), 15 neonates and 9 athletes. In addition, in 21 normal adult subjects (11 men, 10 women) circadian profiles of M concentrations were studied at rest. A significant circadian rhythm was found in 18 out 21 subjects studied, with higher M levels in the morning hours. Children showed low M concentrations (10.8 - 6.1 ng/ml), while in neonates higher M levels were found. Adult men showed significantly higher M levels (26.2 +- 10.3 ng/ml) than women (19.1 +- 7.3 ng/ml) at 8-10 a.m. A significant correlation between body mass and M levels was found in nonobese-adult men, women and athletes (r=0.7195, n=60, p<0.001) at 8-10 a.m. This correlation was also clearly evident at every hour of the day in the 21 subjects studied for circadian profiles. Myoglobin levels greatly increased after physical training. In 6 of 10 hypothyroid patients M was cleary elevated before substitutive therapy; a significant inverse correlation was found between serum M levels and circulating peripheral (free and total) thyroid hormones. Before treatment, in all acromegalics basal M levels were found to be slightly higher than normal, with significant circadian rhythm, as in normals. In addition, a 'biphasic' pattern of M levels in relation to the behaviour of serum GH concentrations was observed. (Author)

  16. Quantification of Lyssavirus-Neutralizing Antibodies Using Vesicular Stomatitis Virus Pseudotype Particles.

    Science.gov (United States)

    Moeschler, Sarah; Locher, Samira; Conzelmann, Karl-Klaus; Krämer, Beate; Zimmer, Gert

    2016-09-16

    Rabies is a highly fatal zoonotic disease which is primarily caused by rabies virus (RABV) although other members of the genus Lyssavirus can cause rabies as well. As yet, 14 serologically and genetically diverse lyssaviruses have been identified, mostly in bats. To assess the quality of rabies vaccines and immunoglobulin preparations, virus neutralization tests with live RABV are performed in accordance with enhanced biosafety standards. In the present work, a novel neutralization test is presented which takes advantage of a modified vesicular stomatitis virus (VSV) from which the glycoprotein G gene has been deleted and replaced by reporter genes. This single-cycle virus was trans-complemented with RABV envelope glycoprotein. Neutralization of this pseudotype virus with RABV reference serum or immune sera from vaccinated mice showed a strong correlation with the rapid fluorescent focus inhibition test (RFFIT). Importantly, pseudotype viruses containing the envelope glycoproteins of other lyssaviruses were neutralized by reference serum to a significantly lesser extent or were not neutralized at all. Taken together, a pseudotype virus system has been successfully developed which allows the safe, fast, and sensitive detection of neutralizing antibodies directed against different lyssaviruses.

  17. Quantification of Lyssavirus-Neutralizing Antibodies Using Vesicular Stomatitis Virus Pseudotype Particles

    Directory of Open Access Journals (Sweden)

    Sarah Moeschler

    2016-09-01

    Full Text Available Rabies is a highly fatal zoonotic disease which is primarily caused by rabies virus (RABV although other members of the genus Lyssavirus can cause rabies as well. As yet, 14 serologically and genetically diverse lyssaviruses have been identified, mostly in bats. To assess the quality of rabies vaccines and immunoglobulin preparations, virus neutralization tests with live RABV are performed in accordance with enhanced biosafety standards. In the present work, a novel neutralization test is presented which takes advantage of a modified vesicular stomatitis virus (VSV from which the glycoprotein G gene has been deleted and replaced by reporter genes. This single-cycle virus was trans-complemented with RABV envelope glycoprotein. Neutralization of this pseudotype virus with RABV reference serum or immune sera from vaccinated mice showed a strong correlation with the rapid fluorescent focus inhibition test (RFFIT. Importantly, pseudotype viruses containing the envelope glycoproteins of other lyssaviruses were neutralized by reference serum to a significantly lesser extent or were not neutralized at all. Taken together, a pseudotype virus system has been successfully developed which allows the safe, fast, and sensitive detection of neutralizing antibodies directed against different lyssaviruses.

  18. The comparison between the humoral response and the neutralizing capacity of sheep serum inoculated with natural venom and Co{sup 60} irradiated venom from Crotalus durissus terrificus (Laurenti, 1768)

    Energy Technology Data Exchange (ETDEWEB)

    Netto, D.P. [Universidade Estadual de Londrina, PR (Brazil). Centro de Ciencias Agrarias. Dept. de Medicina Veterinaria Preventiva]. E-mail: mnetto@uel.br

    2000-07-01

    Crotalus durissus terrificus venom was irradiated with Co{sup 60} to investigate the effects of antigen-irradiation on antivenom production in sheep. Twelve sheep were divided in two groups of 6. One group received irradiated, while the other received natural venom. Three doses of antigen were given at monthly intervals. The toxic activity of the venom was assessed by LD{sub 50} in mice. Weekly blood samples were obtained to evaluate anti-crotalic serum titers by indirect ELISA, neutralization capacity, and serum potency. A complete blood count, plasma protein and fibrinogen concentration, and serum albumin and globulin were also determined. At end of the experiment, the animals were challenged with ovine LD{sub 50}, without clinical abnormalities. (author)

  19. Mimotopes selected by biopanning with high-titer HIV-neutralizing antibodies in plasma from Chinese slow progressors

    Directory of Open Access Journals (Sweden)

    Xiaoli Zhang

    Full Text Available OBJECTIVE: One approach to identifying HIV-1 vaccine candidates is to dissect the natural antiviral immune response in treatment-naïve individuals infected for over ten years, considered slow progressor patients (SPs. It is suspected that SP plasma has strongly neutralizing antibodies (NAb targeting specific HIV viral epitopes. METHODS: NAbs levels of 11 HIV-1-infected SPs were detected by PBMC-based neutralization assays. To investigate SP NAb epitope, this study used a biopanning approach to obtain mimotopes of HIV-1 that were recognized by SP plasma NAbs. IgG was purified from hightiter NAb SP plasma, and used as the ligand for three rounds of biopanning to select HIV-specific mimotopes from a phage-displayed random peptide library. Double-antibody sandwich ELISA, competitive inhibition assays, and peptide sequence analysis were used to evaluate the characteristics of phage-borne mimotopes. RESULTS: SPs had significantly more plasma neutralizing activity than typical progressors (TPs (p = 0.04. P2 and P9 plasma, which have highest-titer HIV-NAb, were selected as ligands for biopanning. After three rounds of biopanning, 48 phage clones were obtained, of which 22 clones were consistent with requirement, binding with HIV-1 positive plasma and unbinding with HIV-1 negative plasma. Compared with linear HIV-1 protein sequence and HIV-1 protein structure files, only 12 clones were possible linear mimotopes of NAbs. In addition, the C40 clone located in gp41 CHR was found to be a neutralizing epitope, which could inhibit pooled HIV-1 positive plasma reaction. CONCLUSION: Biopanning of serum IgG can yield mimotopes of HIV-1-related antigen epitopes. This methodology provides a basis for exploration into HIV-1-related antigen-antibody interactions and furthers NAb immunotherapy and vaccine design.

  20. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  1. An examination of the hexokinase method for serum glucose assay using external quality assessment data.

    Science.gov (United States)

    Westwood, A; Bullock, D G; Whitehead, T P

    1986-01-01

    Hexokinase methods for serum glucose assay appeared to give slightly but consistently higher inter-laboratory coefficients of variation than all methods combined in the UK External Quality Assessment Scheme; their performance over a two-year period was therefore compared with that for three groups of glucose oxidase methods. This assessment showed no intrinsic inferiority in the hexokinase method. The greater variation may be due to the more heterogeneous group of instruments, particularly discrete analysers, on which the method is used. The Beckman Glucose Analyzer and Astra group (using a glucose oxidase method) showed the least inter-laboratory variability but also the lowest mean value. No comment is offered on the absolute accuracy of any of the methods.

  2. Rapid detection of serum antibody by dual-path platform VetTB assay in white-tailed deer infected with Mycobacterium bovis.

    Science.gov (United States)

    Lyashchenko, Konstantin P; Greenwald, Rena; Esfandiari, Javan; O'Brien, Daniel J; Schmitt, Stephen M; Palmer, Mitchell V; Waters, W Ray

    2013-06-01

    Bovine tuberculosis (TB) in cervids remains a significant problem affecting farmed herds and wild populations. Traditional skin testing has serious limitations in certain species, whereas emerging serological assays showed promising diagnostic performance. The recently developed immunochromatographic dual-path platform (DPP) VetTB assay has two antigen bands, T1 (MPB83 protein) and T2 (CFP10/ESAT-6 fusion protein), for antibody detection. We evaluated the diagnostic accuracy of this test by using serum samples collected from groups of white-tailed deer experimentally inoculated with Mycobacterium bovis, M. avium subsp. paratuberculosis, or M. bovis BCG Pasteur. In addition, we used serum samples from farmed white-tailed deer in herds with no history of TB, as well as from free-ranging white-tailed deer culled during field surveillance studies performed in Michigan known to have bovine TB in the wild deer population. The DPP VetTB assay detected antibody responses in 58.1% of experimentally infected animals within 8 to 16 weeks postinoculation and in 71.9% of naturally infected deer, resulting in an estimated test sensitivity of 65.1% and a specificity of 97.8%. The higher seroreactivity found in deer with naturally acquired M. bovis infection was associated with an increased frequency of antibody responses to the ESAT-6 and CFP10 proteins, resulting in a greater contribution of these antigens, in addition to MPB83, to the detection of seropositive animals, compared with experimental M. bovis infection. Deer experimentally inoculated with either M. avium subsp. paratuberculosis or M. bovis BCG Pasteur did not produce cross-reactive antibodies that could be detected by the DPP VetTB assay. The present findings demonstrate the relatively high diagnostic accuracy of the DPP VetTB test for white-tailed deer, especially in the detection of naturally infected animals.

  3. Comparison of humoral immune response, neutralization capacity of anticrotalic serum in young ovines, clinical and weight evaluation between animals inoculated with Crotalus durissus terrificus venom, natural or Cobalt-60-irradiated

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.

    2005-01-01

    The Elisa technique was used to evaluate and compare the humoral immune response of young ovine to anticrotalic serum production. During serum production, the clinical and weight evaluation of the animals was performed. The parameters utilized were complete blood count, and dosage of urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin. The animals weight was verified fortnightly during the experiment. The neutralization capacity of the serum produced from the snake Crotalus durissus terrificus natural (NV) and Cobalt-60-irradiated venom (IrV) was evaluated by in vitro challenges. One group of six animals received natural venom, the second group received irradiated venom, and the third was the control group. The animals received six immunizations during 84 days with an interval of 14 days. There was a significant difference (p<5%) in the ELISA test for the profile of the antibodies produced by the experimental groups (NV< IrV). There was no significant difference (p<5%) for biochemical tests, complete blood count, and animals weight between the three groups tested. The group immunized with irradiated venom showed antibodies profile higher than the group immunized with natural venom. The neutralization capacity of the serum produced from the IrV was fivefold higher when compared to the serum produced with NV. The clinical and weight evaluation showed that the o vines in post-weaning phase did not have their physiological profiles altered, and showed an excellent increase in weight during the experimental period. These results indicate a new perspective for the utilization of o vines, aiming the commercial production of anticrotalic serum, which may be applied in the treatment of human and animal envenomation. The cost for its production may be reduced by the posterior utilization of hyperimmunized ovine in human feeding. (author)

  4. Comparison of humoral immune response, neutralization capacity of anticrotalic serum in young ovines, clinical and weight evaluation between animals inoculated with Crotalus durissus terrificus venom, natural or Cobalt-60-irradiated

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Junior, R.S. E-mail: rseabra@cevap.org.br

    2005-07-01

    The Elisa technique was used to evaluate and compare the humoral immune response of young ovine to anticrotalic serum production. During serum production, the clinical and weight evaluation of the animals was performed. The parameters utilized were complete blood count, and dosage of urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin. The animals weight was verified fortnightly during the experiment. The neutralization capacity of the serum produced from the snake Crotalus durissus terrificus natural (NV) and Cobalt-60-irradiated venom (IrV) was evaluated by in vitro challenges. One group of six animals received natural venom, the second group received irradiated venom, and the third was the control group. The animals received six immunizations during 84 days with an interval of 14 days. There was a significant difference (p<5%) in the ELISA test for the profile of the antibodies produced by the experimental groups (NVneutralization capacity of the serum produced from the IrV was fivefold higher when compared to the serum produced with NV. The clinical and weight evaluation showed that the o vines in post-weaning phase did not have their physiological profiles altered, and showed an excellent increase in weight during the experimental period. These results indicate a new perspective for the utilization of o vines, aiming the commercial production of anticrotalic serum, which may be applied in the treatment of human and animal envenomation. The cost for its production may be reduced by the posterior utilization of hyperimmunized ovine in human feeding. (author)

  5. The value of the indirect immunoradiometric assay of serum alpha - fetoprotein in detecting liver regeneration and neoplastic transformation in chronic liver disease. Part of a coordinated programme on in vitro assay techniques

    International Nuclear Information System (INIS)

    Voiculetz, N.

    1979-07-01

    To investigate the concentration of alphafetoprotein AFP in different liver diseases and above all in liver cancer the immunoradiometric assay was utilized. The results of AFP studies were compared with regeneration index, blastic T lymphocytes transformation as well as other morphological and biochemical data. The results of the investigations indicated that: 38% of chronic benign hepatopathies displayed the values of serum AFP in normal ranges, 54% were in the range of 41 - 200ng/ml, and 8% showed 200 and more ng/ml. The most important conclusion from the work performed was that the elevation of serum AFP level in the evaluation of chronic hepatopathies, especially in cirrhoses, appears as an index of malignancy

  6. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  7. Radioimmunoassay of progesterone in unextracted serum

    International Nuclear Information System (INIS)

    Haynes, S.P.; Corcoran, J.M.; Eastman, C.J.; Doy, F.A.

    1980-01-01

    A rapid, precise radioimmunoassay for progesterone in 25 μL of unextracted serum is described. Progesterone is released from its binding protein by adding an optimal amount of cortisol, which binds to the same protein (cortisol binding globulin) as progesterone. The amount of cortisol required does not cross react with the specific progesterone antibody used. This approach considerably shortens assay time and removes a tedious and imprecise stage in the conventional assay of serum progesterone. Results correlated well (r = 0.97) with a method involving organic solvent extraction of progesterone from serum. During the two years we have used this mehod in a busy diagnostic endocrine laboratory, the between-assay precision (CV) for low-, medium-, and high-concentration quality control sera was 12, 7, and 9%, respectively. Data from participation in an independent external quality-control program verified the adequacies of the method

  8. Lack of Durable Cross-Neutralizing Antibodies Against Zika Virus from Dengue Virus Infection.

    Science.gov (United States)

    Collins, Matthew H; McGowan, Eileen; Jadi, Ramesh; Young, Ellen; Lopez, Cesar A; Baric, Ralph S; Lazear, Helen M; de Silva, Aravinda M

    2017-05-01

    Cross-reactive antibodies elicited by dengue virus (DENV) infection might affect Zika virus infection and confound serologic tests. Recent data demonstrate neutralization of Zika virus by monoclonal antibodies or human serum collected early after DENV infection. Whether this finding is true in late DENV convalescence (>6 months after infection) is unknown. We studied late convalescent serum samples from persons with prior DENV or Zika virus exposure. Despite extensive cross-reactivity in IgG binding, Zika virus neutralization was not observed among primary DENV infections. We observed low-frequency (23%) Zika virus cross-neutralization in repeat DENV infections. DENV-immune persons who had Zika virus as a secondary infection had distinct populations of antibodies that neutralized DENVs and Zika virus, as shown by DENV-reactive antibody depletion experiments. These data suggest that most DENV infections do not induce durable, high-level Zika virus cross-neutralizing antibodies. Zika virus-specific antibody populations develop after Zika virus infection irrespective of prior DENV immunity.

  9. Determination of thymidine in serum used for cell culture media

    International Nuclear Information System (INIS)

    Schaer, J.C.; Maurer, U.; Schindler, R.

    1978-01-01

    Thymidine concentrations in serum used for cell culture media were determined with an assay based on isotope dilution. In this assay, incorporation of (3H)-thymidine into DNA of cultured cells was measured in the presence of 5 and 20% serum as a function of the concentration of unlabeled thymidine added to the medium. Thymidine concentrations were measured using horse serum as well as fetal calf serum in the culture media. Dialysis of serum resulted in a reduction of thymidine levels by factors of at least 10

  10. Evaluation of the Aptima HBV Quant assay vs. the COBAS TaqMan HBV test using the high pure system for the quantitation of HBV DNA in plasma and serum samples.

    Science.gov (United States)

    Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin

    2018-03-28

    Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target 0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.

  11. Inactivated H7 Influenza Virus Vaccines Protect Mice despite Inducing Only Low Levels of Neutralizing Antibodies.

    Science.gov (United States)

    Kamal, Ram P; Blanchfield, Kristy; Belser, Jessica A; Music, Nedzad; Tzeng, Wen-Pin; Holiday, Crystal; Burroughs, Ashley; Sun, Xiangjie; Maines, Taronna R; Levine, Min Z; York, Ian A

    2017-10-15

    Avian influenza viruses of the H7 hemagglutinin (HA) subtype present a significant public health threat, as evidenced by the ongoing outbreak of human A(H7N9) infections in China. When evaluated by hemagglutination inhibition (HI) and microneutralization (MN) assays, H7 viruses and vaccines are found to induce lower level of neutralizing antibodies (nAb) than do their seasonal counterparts, making it difficult to develop and evaluate prepandemic vaccines. We have previously shown that purified recombinant H7 HA appear to be poorly immunogenic in that they induce low levels of HI and MN antibodies. In this study, we immunized mice with whole inactivated reverse genetics reassortant (RG) viruses expressing HA and neuraminidase (NA) from 3 different H7 viruses [A/Shanghai/2/2013(H7N9), A/Netherlands/219/2003(H7N7), and A/New York/107/2003(H7N2)] or with human A(H1N1)pdm09 (A/California/07/2009-like) or A(H3N2) (A/Perth16/2009) viruses. Mice produced equivalent titers of antibodies to all viruses as measured by enzyme-linked immunosorbent assay (ELISA). However, the antibody titers induced by H7 viruses were significantly lower when measured by HI and MN assays. Despite inducing very low levels of nAb, H7 vaccines conferred complete protection against homologous virus challenge in mice, and the serum antibodies directed against the HA head region were capable of mediating protection. The apparently low immunogenicity associated with H7 viruses and vaccines may be at least partly related to measuring antibody titers with the traditional HI and MN assays, which may not provide a true measure of protective immunity associated with H7 immunization. This study underscores the need for development of additional correlates of protection for prepandemic vaccines. IMPORTANCE H7 avian influenza viruses present a serious risk to human health. Preparedness efforts include development of prepandemic vaccines. For seasonal influenza viruses, protection is correlated with antibody

  12. Toxicity of binary chemical munition destruction products: methylphosphonic acid, methylphosphinic acid, 2-diisopropylaminoethanol, DF neutralent, and QL neutralent.

    Science.gov (United States)

    Watson, Rebecca E; Hafez, Ahmed M; Kremsky, Jonathan N; Bizzigotti, George O

    2007-01-01

    This paper reports the toxicity and environmental impact of neutralents produced from the hydrolysis of binary chemical agent precursor chemicals DF (methylphosphonic difluoride) and QL (2-[bis(1-methylethyl)amino]ethyl ethyl methylphosphonite). Following a literature review of the neutralent mixtures and constituents, basic toxicity tests were conducted to fill data gaps, including acute oral and dermal median lethal dose assays, the Ames mutagenicity test, and ecotoxicity tests. For methylphosphonic acid (MPA), a major constituent of DF neutralent, the acute oral LD(50) in the Sprague-Dawley rat was measured at 1888 mg/kg, and the Ames test using typical tester strains of Salmonella typhimurium and Escherichia coli was negative. The 48-h LC(50) values for pH-adjusted DF neutralent with Daphnia magna and Cyprinodon variegatus were > 2500 mg/L and 1593 mg/L, respectively. The acute oral LD(50) values in the rat for QL neutralent constituents methylphosphinic acid (MP) and 2-diisopropylaminoethanol (KB) were both determined to be 940 mg/kg, and the Ames test was negative for both. Good Laboratory Practice (GLP)-compliant ecotoxicity tests for MP and KB gave 48-h D. magna EC(50) values of 6.8 mg/L and 83 mg/L, respectively. GLP-compliant 96-h C. variegatus assays on MP and KB gave LC(50) values of 73 and 252 mg/L, respectively, and NOEC values of 22 and 108 mg/L. QL neutralent LD(50) values for acute oral and dermal toxicity tests were both > 5000 mg/kg, and the 48-h LD(50) values for D. magna and C. variegatus were 249 and 2500 mg/L, respectively. Using these data, the overall toxicity of the neutralents was assessed.

  13. False positive acetaminophen concentrations in icteric serum

    Directory of Open Access Journals (Sweden)

    L. de Jong

    2016-04-01

    Full Text Available Introduction: Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. Description: A 49-year-old woman was admitted to our hospital with a hepatic encephalopathy and a total serum bilirubin concentration of 442 µmol/l. The acetaminophen concentration of 11.5 mg/l was measured with an enzymatic-colorimetric assay, thus treatment with N-acetyl cysteine was started. Interestingly, the acetaminophen concentration remained unchanged (11.5–12.3 mg/l during a period of 4 consecutive days. In contrast, the acetaminophen concentration measured by HPLC, a chromatographic technique, remained undetectable Discussion: In the presented case, elevated bilirubin was the most likely candidate to interfere with acetaminophen assay causing false positive results. Bilirubin has intense absorbance in the ultraviolet and visible regions of the electromagnetic spectrum and for that reason it causes interference in an enzymatic-colorimetric assay. Conclusion: False positive acetaminophen laboratory test results may be found in icteric serum, when enzymatic-colorimetric assays are used for determination of an acetaminophen concentration. Questionable acetaminophen results in icteric serum should be confirmed by a non-enzymatic method, by means of ultrafiltration of the serum, or by dilution studies. Keywords: Acetaminophen, Enzymatic-colorimetric assays, HPLC, Bilirubin, Interference, Paracetamol, Liver failure, Jaundice

  14. Isotope derivative assay of human serum bile acids

    International Nuclear Information System (INIS)

    Pageaux, J.F.; Duperray, B.; Dubois, M.; Pacheco, H.

    1981-01-01

    A new method for the selective determination of the main serum bile acids has been developed. Serum samples with added 14 C-labeled bile acid were submitted to deproteinization, alkaline hydrolysis, methylation, and were then chromatographed on alumina before acetylation with 2 microliters of [ 3 H]acetic anhydride. Excess reagent was eliminated by evaporation; elimination of residual tritiated contaminants and separation of the doubly labeled bile acid derivatives were obtained by thin-layer chromatography, column chromatography on Lipidex 5000, and crystallization. The sensitivity of the method is about 10 pmol of each bile acid. Analyses of seven sera with normal or elevated concentration of bile acids by the proposed method and gas-liquid chromatography showed a close correlation

  15. A novel radioassay for the determination of folate in serum and red cells and new observations on the stability of serum folate

    International Nuclear Information System (INIS)

    Lynch, E.P.J.; Tovey, K.C.; Guilford, H.

    1977-01-01

    A Competitive Protein Binding assay for the determination of folate in serum and red cells has been developed. The assay has been fully validated in hospital trials and comparisons have been made with the microbiological assay. We have based the standardization of the radioassay on N 5 -methyltetrahydrofolate (N 5 -MTHF) as this is the predominant folate derivative in serum samples. At about pH 9.5 pteroylglutamic acid (PGA) and N 5 -MTHF demonstrate the same affinity for folate binding proteins. Therefore, many folate assays have adopted PGA largely because of the popular belief that N 5 -MTHF is highly unstable. However, we have demonstrated that N 5 -MTHF in serum standards is surprisingly stable at -20 0 C. All the reagents for the assay (including the N 5 -MTHF standards) have shown perfectly acceptable stability, permitting their storage for at least three weeks at -20 0 C and one week at 4 0 C. Evidence will be presented to support the use of N 5 -MTHF as being the more appropriate standard. Folate in human serum samples is stable even at room temperature in the presence of 0.1% sodium azide. (orig./AJ) [de

  16. Assay system

    International Nuclear Information System (INIS)

    Patzke, J.B.; Rosenberg, B.J.

    1984-01-01

    The accuracy of assays for monitoring concentrations of basic drugs in biological fluids containing a 1 -acid glycoproteins, such as blood (serum or plasma), is improved by the addition of certain organic phosphate compounds to minimize the ''protein effect.'' Kits containing the elements of the invention are also disclosed

  17. Diagnosis of Barmah Forest virus infection by a nested real-time SYBR green RT-PCR assay.

    Directory of Open Access Journals (Sweden)

    Linda Hueston

    Full Text Available Barmah Forest virus (BFV is a mosquito borne (+ ssRNA alphavirus found only in Australia. It causes rash, myalgia and arthralgia in humans and is usually diagnosed serologically. We developed a real-time PCR assay to detect BFV in an effort to improve diagnosis early in the course of infection. The limit of detection was 16 genome equivalents with a specificity of 100%. Fifty five serum samples from BFV-infected patients were tested by the PCR. 52 of 53 antibody-positive samples were PCR negative. Two culture-positive (neutralizing antibody negative samples were positive on first round PCR, while one sample (IgM and neutralizing antibody strongly positive, IgG negative was positive on second round PCR, suggesting that viral RNA is detectable and transiently present in early infection. PCR can provide results faster than culture, is capable of high throughput and by sequencing the PCR product strain variants can be characterized.

  18. Use of enzyme-linked immunosorbent assay and dipstick assay for detection of Strongyloides stercoralis infection in humans

    NARCIS (Netherlands)

    van Doorn, H. Rogier; Koelewijn, Rob; Hofwegen, Henk; Gilis, Henk; Wetsteyn, Jose C. F. M.; Wismans, Pieter J.; Sarfati, Claudine; Vervoort, Tony; van Gool, Tom

    2007-01-01

    A homemade enzyme-linked immunosorbent assay (ELISA) (Academic Medical Center ELISA [AMC-ELISA]) and a dipstick assay for the detection of anti-Strongyloides stercoralis antibodies in serum were developed and evaluated together with two commercially available ELISAs (IVD-ELISA [IVD Research, Inc.

  19. Development of insusceptibility to serum factor during the radiation transformation process

    International Nuclear Information System (INIS)

    Terasima, T.; Yasukawa, M.; Kimura, M.

    1983-01-01

    The effects of using different assay sera on the X-ray-induced transformation yield in 10T1/2 mouse cells were studied. The use of newborn calf assay serum gave a 5 x greater value of transformation than foetal calf serum. This difference in transformation yield with different assay sera was used to investigate the time interval required for the development of insusceptibility of cells to serum factor. Sequential shifting from low yield sera (LYS) to high yield sera (HYS) showed that the radiation-initiated cells were most susceptible to HYS at the beginning of the assay culture but finally became insusceptible within 2 weeks of incubation. (U.K.)

  20. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.

    Science.gov (United States)

    Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L

    2017-09-01

    C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision assay precision ELISA demonstrated a significant correlation with RIA (R

  1. Diagnostic efficacy of monoclonal antibody based sandwich enzyme linked immunosorbent assay (ELISA for detection of Fasciola gigantica excretory/secretory antigens in both serum and stool

    Directory of Open Access Journals (Sweden)

    Zoheiry Mona K

    2011-09-01

    Full Text Available Abstract Background This research was carried out to develop a reliable monoclonal antibody (MoAb-based sandwich enzyme linked immunosorbent assay (ELISA for the diagnosis of active Fasciola gigantica infection in both serum and stool for comparative purposes. Methods From a panel of MoAbs raised against F. gigantica excretory/secretory antigens (ES Ags, a pair (12B/11D/3F and 10A/9D/10G was chosen due to its high reactivity and strict specificity to F. gigantica antigen by indirect ELISA. Results The two MoAbs were of the IgG1 and IgG2a subclasses, respectively. Using SDS-PAGE and EITB, the selected MoAbs recognized 83, 64, 45 and 26 kDa bands of ES Ags. The lower detection limit of ELISA assay was 3 ng/ml. In stool, the sensitivity, specificity and diagnostic efficacy of ELISA was 96%, 98.2 and 97.1%; while in serum they were 94%, 94.6% and 94.3%, respectively. Moreover, a positive correlation was found between ova count in stool of F. gigantica infected patients and the OD readings of ELISA in both stool and serum samples (r = 0.730, p Conclusions These data showed that the use of MoAb-based sandwich ELISA for the detection of F. gigantica coproantigens in stool specimens was superior to serum samples; it provides a highly efficient, non-invasive technique for the diagnosis of active F. gigantica infection.

  2. A national quality control scheme for serum HGH assays

    International Nuclear Information System (INIS)

    Hunter, W.M.; McKenzie, I.

    1979-01-01

    In the autumn of 1975 the Supraregional Assay Service established a Quality Control Sub-Committee and the intra-laboratory QC Scheme for Growth Hormone (HGH) assays which is described here has served, in many respects, as a pilot scheme for protein RIA. Major improvements in accuracy, precision and between-laboratory agreement can be brought about by intensively interactive quality control schemes. A common standard is essential and should consist of ampoules used for one or only a small number of assays. Accuracy and agreement were not good enough to allow the overall means to serve as target values but a group of 11 laboratories were sufficiently accurate to provide a 'reference group mean' to so serve. Gross non-specificity was related to poor assay design and was quickly eliminated. Within-laboratory between-batch variability was much worse than that normally claimed for simple protein hormone RIA. A full report on this Scheme will appear shortly in Annals of Clinical Biochemistry. (Auth.)

  3. Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction-Measurement by ELISA.

    Directory of Open Access Journals (Sweden)

    Shozo Yokoyama

    Full Text Available Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA.One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH. Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay.A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference and the addition of bovine serum albumin (BSA resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA.We optimized an easy and rapid detection method for assessment of

  4. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  5. A simple and rapid Hepatitis A Virus (HAV titration assay based on antibiotic resistance of infected cells: evaluation of the HAV neutralization potency of human immune globulin preparations

    Directory of Open Access Journals (Sweden)

    Kaplan Gerardo G

    2008-12-01

    Full Text Available Abstract Background Hepatitis A virus (HAV, the causative agent of acute hepatitis in humans, is an atypical Picornaviridae that grows poorly in cell culture. HAV titrations are laborious and time-consuming because the virus in general does not cause cytopathic effect and is detected by immunochemical or molecular probes. Simple HAV titration assays could be developed using currently available viral construct containing selectable markers. Results We developed an antibiotic resistance titration assay (ARTA based on the infection of human hepatoma cells with a wild type HAV construct containing a blasticidin (Bsd resistance gene. Human hepatoma cells infected with the HAV-Bsd construct survived selection with 2 μg/ml of blasticidin whereas uninfected cells died within a few days. At 8 days postinfection, the color of the pH indicator phenol red in cell culture media correlated with the presence of HAV-Bsd-infected blasticidin-resistant cells: an orange-to-yellow color indicated the presence of growing cells whereas a pink-to-purple color indicated that the cells were dead. HAV-Bsd titers were determined by an endpoint dilution assay based on the color of the cell culture medium scoring orange-to-yellow wells as positive and pink-to-purple wells as negative for HAV. As a proof-of-concept, we used the ARTA to evaluate the HAV neutralization potency of two commercially available human immune globulin (IG preparations and a WHO International Standard for anti-HAV. The three IG preparations contained comparable levels of anti-HAV antibodies that neutralized approximately 1.5 log of HAV-Bsd. Similar neutralization results were obtained in the absence of blasticidin by an endpoint dilution ELISA at 2 weeks postinfection. Conclusion The ARTA is a simple and rapid method to determine HAV titers without using HAV-specific probes. We determined the HAV neutralization potency of human IG preparations in 8 days by ARTA compared to the 14 days required by the

  6. Detection and serotyping of dengue virus in serum samples by multiplex reverse transcriptase PCR-ligase detection reaction assay.

    Science.gov (United States)

    Das, S; Pingle, M R; Muñoz-Jordán, J; Rundell, M S; Rondini, S; Granger, K; Chang, G-J J; Kelly, E; Spier, E G; Larone, D; Spitzer, E; Barany, F; Golightly, L M

    2008-10-01

    The detection and successful typing of dengue virus (DENV) from patients with suspected dengue fever is important both for the diagnosis of the disease and for the implementation of epidemiologic control measures. A technique for the multiplex detection and typing of DENV serotypes 1 to 4 (DENV-1 to DENV-4) from clinical samples by PCR-ligase detection reaction (LDR) has been developed. A serotype-specific PCR amplifies the regions of genes C and E simultaneously. The two amplicons are targeted in a multiplex LDR, and the resultant fluorescently labeled ligation products are detected on a universal array. The assay was optimized using 38 DENV strains and was evaluated with 350 archived acute-phase serum samples. The sensitivity of the assay was 98.7%, and its specificity was 98.4%, relative to the results of real-time PCR. The detection threshold was 0.017 PFU for DENV-1, 0.004 PFU for DENV-2, 0.8 PFU for DENV-3, and 0.7 PFU for DENV-4. The assay is specific; it does not cross-react with the other flaviviruses tested (West Nile virus, St. Louis encephalitis virus, Japanese encephalitis virus, Kunjin virus, Murray Valley virus, Powassan virus, and yellow fever virus). All but 1 of 26 genotypic variants of DENV serotypes in a global DENV panel from different geographic regions were successfully identified. The PCR-LDR assay is a rapid, sensitive, specific, and high-throughput technique for the simultaneous detection of all four serotypes of DENV.

  7. Assay of oestrogen

    International Nuclear Information System (INIS)

    Edwards, J.C.

    1981-01-01

    A particular problem with the direct radioimmunoassay of unconjugated oestriol in pregnancy is caused by the increased amount of steroid-binding proteins present in pregnancy serum and plasma. The steroid-binding proteins react with oestriol and 125 I-labelled oestriol during the assay procedure and the steroid-protein bound 125 I-labelled oestriol is precipitated along with the antibody-bound 125 I-labelled oestriol by the ammonium sulphate solution separation system. A novel method is described whereby progesterone (1-20 μg/ml) is used to block the action of steroid-binding proteins in pregnancy serum and plasma samples, thus minimizing interference in a direct radioimmunoassay for unconjugated oestriol using a specific anti-oestriol serum. (U.K.)

  8. IgD multiple myeloma: Clinical, biological features and prognostic value of the serum free light chain assay.

    Science.gov (United States)

    Djidjik, R; Lounici, Y; Chergeulaïne, K; Berkouk, Y; Mouhoub, S; Chaib, S; Belhani, M; Ghaffor, M

    2015-09-01

    IgD multiple myeloma (MM) is a rare subtype of myeloma, it affects less than 2% of patients with MM. To evaluate the clinical and prognostic attributes of serum free light chains (sFLCs) analysis, we examined 17 cases of IgD MM. From 1998 to 2012, we obtained 1250 monoclonal gammapathies including 590 multiple myeloma and 17 patients had IgD MM. With preponderance of men patients with a mean age at diagnosis of: 59±12years. Patients with IgD MM have a short survival (Median survival=9months). The presenting features included: bone pain (75%), lymphadenopathy (16%), hepatomegaly (25%), splenomegaly (8%), associated AL amyloidosis (6%), renal impairment function (82%), infections (47%), hypercalcemia (37%) and anemia (93%). Serum electrophoresis showed a subtle M-spike (Mean=13.22±10g/L) in all patients associated to a hypogammaglobulinemia. There was an over-representation of Lambda light chain (65%); high serum β2-microglobulin in 91% and Bence Jones proteinuria was identified in 71%. The median rate of sFLCs κ was 19.05mg/L and 296.75mg/L for sFLCs λ. sFLCR was abnormal in 93% of patients and it showed concordance between baseline sFLCR and the survival (P=0.034). The contribution of FLC assay is crucial for the prognosis of patients with IgD MM. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. Clinical applications of HPLC-competitive protein binding assay for serum 25-hydroxyvitamin D

    Energy Technology Data Exchange (ETDEWEB)

    Shouli, Yang [China-Japan Friendship Hospital, Beijing, BJ (China). Inst. of Clinical Medical Science; and others

    1989-08-01

    This report describes the clinical applications of HPLC-competitive protein binding assay for serum 25(OH) Vit D in 156 cases. Serum 25(OH) Vit D of normal human was 33.1 +- 14.8 nmol/L (13.2 +- 5.9 ng/ml), while for various diseases are as follows: rickets, 18.0 +- 9.0 nmol/L (7.2 +- 3.6 ng/ml, n = 36, P < 0.005); hypervitaminosis D, 116.8 +- 31.3 nmol/L (46.7 +- 12.3 ng/ml, n = 6, P < 0.001); renal diseases of children, 25.3 +- 7.3 nmol/L (10.1 +- 2.9 ng/ml, n = 9. P > 0.1); pneumonia of children, 33.8 +- 14.8 nmol/L (13.5 +- 5.9 ng/ml, n = 10, P > 0.5); cirrhosis, 13.8 +- 11.3 nmol/L (5.5 +- 4.5 ng/ml, n = 9, P < 0.001); vasculitis, 25.5 +- 15.3 nmol/L (10.2 +- 6.1 ng/ml, n = 5, P > 0.2); administration of anticonvulsant (1 to 15 years), 19.0 +- 6.5 nmol/L (7.6 +- 2.6 ng/ml, n = 19, P < 0.001); administration of glococorticoids (> 6 months), 15.3 +- 5.0 nmol/L (6.1 +- 2.0 ng/ml, n = 6, P < 0.005); hyperthyroidism, 34.0 +- 23.5 nmol/L (13.6 +- 9.4 ng/ml, n = 13, P > 0.5); pregnant women, 39.8 +- 16.5 nmol/L (15.9 +- 6.6 ng/ml, n = 7, P > 0.1). We found it is a useful reference value for most of the above diseased state especially for differentiation between rickets and hypervitaminosis.

  10. Establishment of an animal challenge model as a potency assay for an inactivated Enterovirus Type 71 vaccine.

    Science.gov (United States)

    Wang, Kun-Teng; Lin, Shih-Jie; Wang, Hsiu-Chi; Chen, Pin-Chun; Lin, Jiao-Jung; Chiang, Jen-Ron; Chang, Chao-Liang; Shih, Daniel Yang-Chih; Lo, Chi-Fang; Wang, Der-Yuan

    2016-07-01

    Enterovirus 71 (EV71) belongs to the Enterovirus genus of the Picornaviridae family, and its occurrence in Asia is associated with hand-foot-and-mouth disease (HFMD), leading to death in some cases, in young children. An effective EV71 vaccine is therefore urgently needed. In this study, we established a two-step EV71 vaccine potency model. Intraperitoneal injections in 2-day-old suckling mice were used to establish the LD50 of EV71 B4, B5, C2, C4, and C5 subgenotypes. Only C4 caused hind limb paralysis in mice (LD50: 2.62 ± 0.45). EV71 VP1 protein was identified in the brain tissues at histology. In the second phase of the model, 3-week-old female ICR mice received one primary and two boosting i.p. injections of formalin-inactivated EV71 B4 and C4 vaccine. Immunized serum was neutralized in vitro with EV71 C4 and applied to the murine challenge model. The C4 vaccine-immunized serum exhibited the highest protective titre (ED50 = 114.6), while the B4 immunized serum had the weakest protective titre (ED50 = 34.3). Additionally, human plasma and intravenous immunoglobulin displayed significant protection in the neutralization assay. Our results could facilitate candidate EV71 vaccine immunogenicity and efficacy evaluations, and may help establish reference EV71 antisera in the future. Copyright © 2016 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  11. Antibody induced by immunization with the Jeryl Lynn mumps vaccine strain effectively neutralizes a heterologous wild-type mumps virus associated with a large outbreak.

    Science.gov (United States)

    Rubin, Steven A; Qi, Li; Audet, Susette A; Sullivan, Bradley; Carbone, Kathryn M; Bellini, William J; Rota, Paul A; Sirota, Lev; Beeler, Judy

    2008-08-15

    Recent mumps outbreaks in older vaccinated populations were caused primarily by genotype G viruses, which are phylogenetically distinct from the genotype A vaccine strains used in the countries affected by the outbreaks. This finding suggests that genotype A vaccine strains could have reduced efficacy against heterologous mumps viruses. The remote history of vaccination also suggests that waning immunity could have contributed to susceptibility. To examine these issues, we obtained consecutive serum samples from children at different intervals after vaccination and assayed the ability of these samples to neutralize the genotype A Jeryl Lynn mumps virus vaccine strain and a genotype G wild-type virus obtained during the mumps outbreak that occurred in the United States in 2006. Although the geometric mean neutralizing antibody titers against the genotype G virus were approximately one-half the titers measured against the vaccine strain, and although titers to both viruses decreased with time after vaccination, antibody induced by immunization with the Jeryl Lynn mumps vaccine strain effectively neutralized the outbreak-associated virus at all time points tested.

  12. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.

    Science.gov (United States)

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2016-04-01

    We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automated 25(OH)D assays (Abbott, Beckman, and Roche). The accuracy of each assay tested was evaluated against a Labquality reference serum panel for 25(OH)D (Ref!25OHD; University of Ghent). Intra- and inter-day imprecision of the Fujirebio 25(OH)D assay was Lumipulse G 25-OH vitamin D assay from Fujirebio demonstrated a good correlation with LC-MS/MS and some immunoassays. The performance of the assay is well-suited for routine 25(OH)D measurement in clinical serum samples. A correction for the observed negative bias vs. LC-MS/MS could be considered.

  13. Physiological serum copper concentrations found in malignancies cause unfolding induced aggregation of human serum albumin in vitro.

    Science.gov (United States)

    Rizvi, Asim; Furkan, Mohd; Naseem, Imrana

    2017-12-15

    Malignancies are characterized by several drastic metabolic changes, one of which is a progressive rise in the levels of serum copper. This rise in serum copper is documented across all malignancies and across malignancies in several species. This study aims to explore in vitro the effect of increased copper levels on the structure of the blood protein human serum albumin. Exposure of human serum albumin to physiologically relevant copper concentrations for 21 days resulted in structural modifications in the protein which were evident by changes in the intrinsic florescence. A loss of the predominantly alpha helical structure of human serum albumin was recorded along with a tendency to form protein aggregates. This aggregation was characterized by Thioflavin T and Congo Red assays. Rayleigh light scattering and turbidity assays confirmed aggregation. The aggregates were visually confirmed using transmission electron microscopy. This is the first report implicating increased copper levels as a cause of aggregation of blood proteins in malignancies. The physiological and biochemical implications of this phenomenon are discussed. Copyright © 2017. Published by Elsevier Inc.

  14. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  15. Diagnostic sensitivity of two radio receptor assays (TRAK Assay and TRAK Dyno human) for the detection of TSH receptor antibodies

    International Nuclear Information System (INIS)

    Paunkovic, N.; Paunkovic, J.

    2003-01-01

    Radio receptor assays for the detection of TSH receptor antibodies in serum are typically based on binding the competition of TSH-R antibodies and 125I -labelled-TSH for membrane preparation of thyrocytes (TBII tests). The sensitivity of the available tests utilizing porcine cell membranes was found to be around 80%. A new test (TRAK Dyno human, BRAHMS) utilizes human recombinant TSH receptor and human standard material that is supposed to improve the performance of the test. We have compared the results of these two assays. The sensitivity of the TRAK Assay tested in 356 patients with untreated Grave's disease was found to be 85%, and 97.5% for TRAK Dyno human in 111 newly diagnosed patients. Both tests were performed from the same serum specimen for 60 of the investigated patients. The TRAK Assay was positive in 50 patients (83.2%) and TRAK Dyno human in 59 patients (98.3%). The specificity of the new radio receptor assay was also improved. (author)

  16. An improved ultrafiltration method for determining free testosterone in serum

    International Nuclear Information System (INIS)

    Vlahos, I.; MacMahon, W.; Sgoutas, D.; Bowers, W.; Thompson, J.; Trawick, W.

    1982-01-01

    In this method, we use the Amicon MPS-1 centrifugal ultrafiltration device and the YMB membrane in measuring free testosterone in serum. Two independent assays are combined: total testosterone and the ultrafiltrable fraction of added [ 3 H]testosterone. The unbound fraction is determined in 0.15-0.5 mL ultrafiltrates of 0.6 to 1 mL of variably diluted serum that has been equilibrated with [ 3 H]testosterone at 37 degrees C. The assay is rapid (less than 1 h), practicable (requires 0.6 mL of serum), and reproducible (CV 3.2% within assay, 3.9% between assays). Accuracy was evaluated as the fraction of free testosterone in the ultrafiltrate of dialyzed serum vs that in a prior dialysate; they were the same confirming the validity of the free testosterone measurement. Samples from ostensibly healthy men and women and from hirsute and pregnant women gave results that agreed with those obtained by equilibrium dialysis. Total testosterone concentrations for normal and hirsute women showed considerable overlap, but data on free testosterone concentrations in these populations were better resolved

  17. Radioligand binding assay of cortisol using horse transcortin

    International Nuclear Information System (INIS)

    Dash, R.J.; Sharma, B.R.; Lata, V.

    1979-01-01

    A modified radioligand binding assay was developed to measure cortisol in a single methylene chloride extract of human plasma/serum. The assay utilises 5 percent horse serum for cortisol binding and 3 H-cortisol as tracer. Except for a cross reaction of 13.3 percent for cortisone and 7 percent for prednisolone that for other steroids tested was negligible. The assay sensitivity at the lower 95 percent inhibition of buffer controls was 20 pg/tube. The log dose logit response standard curve was linear between 80 pg and 5 ng/tube. Recovery(Y) of cortisol added (x) to male and pregnant female plasma was quantitated (y = 0.983 X-0.47, r = 0.98). Regression analysis of cortisol estimates obtained in 51 plasma/serum samples with this assay system and a specific radioimmunoassay (using cortisol-3-BSA antiserum) for plasma cortisol gave a coefficient of correlation (r) of 0.95 and a regression coefficient (b) of 0.97. The method was found to be simple and highly reproducible. Availability of all reagents in the aqueous phase permitted handling of a large number of samples by a single technician. (auth.)

  18. Serum-converted platelet lysate can substitute for fetal bovine serum in human mesenchymal stromal cell cultures.

    Science.gov (United States)

    Mojica-Henshaw, Mariluz P; Jacobson, Pam; Morris, Julie; Kelley, Linda; Pierce, Jan; Boyer, Michael; Reems, Jo-Anna

    2013-12-01

    Fetal bovine serum (FBS) is commonly used as a serum supplement for culturing human mesenchymal stromal cells (hMSCs). However, human cells grown in FBS, especially for extended periods, risk potential exposure to bovine immunogenic proteins and infectious agents. To address this issue, we investigated the ability of a novel human platelet serum supplement to substitute for FBS in hMSC cultures. Platelet lysate-serum (PL-serum) was converted from platelet lysate-plasma (PL-plasma) that was manufactured from pooled platelet-rich plasma (PRP) apheresis units. Growth factor levels and the number of residual intact platelets in PL-serum and PL-plasma were compared with enzyme-linked immunosorbent assays and flow cytometry, respectively. Proliferation responses of hMSCs cultured in PL-serum, PL-plasma, or FBS were assessed with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, the immunophenotype of harvested hMSCs was evaluated by flow cytometry and tri-lineage differentiation potential was evaluated by assessing adipogenic, osteogenic and chondrogenic development. Selected growth factor levels in PL-serum were not significantly different from PL-plasma (P > 0.05). hMSC cultures supplemented with PL-serum had comparable growth kinetics to PL-plasma, and hMSC yields were consistently greater than with FBS. hMSCs harvested from cultures supplemented with PL-serum, PL-plasma or FBS had similar cell surface phenotypes and maintained tri-lineage differentiation potential. PL-serum, similar to PL-plasma, can substitute for FBS in hMSC cultures. Use of PL-serum, in contrast to PL-plasma, has an added advantage of not requiring addition of a xenogeneic source of heparin, providing a completely xeno-free culture medium. Copyright © 2013 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  19. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    Science.gov (United States)

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low

  20. Antibody neutralization of retargeted measles viruses

    Science.gov (United States)

    Lech, Patrycja J.; Pappoe, Roland; Nakamura, Takafumi; Tobin, Gregory J.; Nara, Peter L.; Russell, Stephen J.

    2014-01-01

    The measles virus (MV) vaccine lineage is a promising oncolytic but prior exposure to the measles vaccine or wild-type MV strains limits treatment utility due to the presence of anti-measles antibodies. MV entry can be redirected by displaying a polypeptide ligand on the Hemagglutinin (H) C-terminus. We hypothesized that retargeted MV would escape neutralization by monoclonal antibodies (mAbs) recognizing the H receptor-binding surface and be less susceptible to neutralization by human antisera. Using chimeric H proteins, with and without mutations that ablate MV receptor binding, we show that retargeted MVs escape mAbs that target the H receptor-binding surface by virtue of mutations that ablate infection via SLAM and CD46. However, C-terminally displayed domains do not mediate virus entry in the presence of human antibodies that bind to the underlying H domain. In conclusion, utility of retargeted oncolytic measles viruses does not extend to evasion of human serum neutralization. PMID:24725950

  1. Development of a swine specific 9-plex Luminex cytokine assay and assessment of immunity after porcine reproductive and respiratory syndrome virus (PRRSV) vaccination: Elevated serum IL-12 levels are not predictive of protect

    Science.gov (United States)

    A Luminex multiplex swine cytokine assay was developed to measure 9 cytokines simultaneously in pig serum and tested in a porcine reproductive and respiratory syndrome virus (PRRSV) vaccine/challenge study. This assay detects innate (IL-1ß, IL-6, IL-8, IFNa, TNFa); regulatory (IL-10), Th1 (IL-12, I...

  2. [Clinical evaluation of a novel HBsAg quantitative assay].

    Science.gov (United States)

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  3. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  4. The measurement of TSH-receptor autoantibodies in human serum by radioreceptor assay

    International Nuclear Information System (INIS)

    Truong, T.X.

    2002-01-01

    TSH receptor autoantibodies (TRAB) are valuable in Graves' disease with a sensitivity of 85% and a specificity of 80%. Autoantibodies levels decrease progressively with antithyroid drugs treatment or after thyroidectomy. The predictive value of the level of TSH receptor autoantibodies is diversely appreciated. Nevertheless, the vast majority of the studies agrees on the fact that high levels of TSH receptor autoantibodies predict a relapse. The feto-placental transfer of these antibodies could explain congenital hyperthyroidism of newborns from mother affected by Graves' disease. These antibodies are present in certain cases of Hashimoto thyroiditis, subacute thyroiditis or silent thyroiditis in phase of thyrotoxicosis. In Vietnam, first time we have researched determination of TRAB levels in the non disease and the Graves' disease, after treatment of antithyroid drugs and after thyroidectomy. We imported TRAB - Kit from CIS bio international France. The principle of Radioreceptor assay (RRA ) is following: TR - Ab kit utilizes a principle of competition between TSH receptor autoantibodies present in the sample and bovine TSH radiolabelled with 125 -I, facing a fixed and limited amount of soluble porcine TSH receptors. The more TSH receptor autoantibodies are present in the sample, the less 125 -I- TSH is bound to the soluble TSH receptors. Free and bound fractions are separated in adding PEG solution followed by a centrifugation. Results are calculated from a calibration curve (U/l). The samples were counted by the multi crystal gamma counter Oakfield which was supplied from IAEA (Years 2000). This is the first study in Vietnam, the concentration of TSH receptor autoantibodies (TRAB) was determined by radioreceptor assay (RRA) on 30 normal subjects and 30 Grave's disease subjects. The normal range is 1,4 □ 0.6 U/l. Max of normal is 2.99U/l. Min of normal is 3.38U/l .There are 11 males and 29 females with age from 15 to 50 years old. Mean of Graves' disease is

  5. Competitive binding thyroid assay with improved bound-free separation step

    International Nuclear Information System (INIS)

    1979-01-01

    A competitive binding assay is described for serum thyroid hormone using 125 I-labelled thyroid hormone and exogenous thyroid hormone binding protein. The unbound thyroid hormone is separated from thyroid hormone bound to thyroid hormone binding protein using an intermediate base anion exchange resin. This resin comprises tertiary and quaternary amine groups on a polyalkyleneamine lattice and is compressed with microcrystalline cellulose in a tablet form. The assay technique of the present invention employing an intermediate base anion resin was found to give superior results compared with alternative assay techniques used in serum thyroid hormone estimation. (UK)

  6. Neutralizing Antibody Response and Efficacy of Novel Recombinant Tetravalent Dengue DNA Vaccine Comprising Envelope Domain III in Mice

    Directory of Open Access Journals (Sweden)

    Ajit Kulkarni

    2017-03-01

    Full Text Available Background: Dengue is a global arboviral threat to humans; causing 390 million infections per year. The availability of safe and effective tetravalent dengue vaccine is a global requirement to prevent epidemics, morbidity, and mortality associated with it. Methods: Five experimental groups (6 mice per group each of 5-week-old BALB/c mice were immunized with vaccine and placebo (empty plasmid (100 µg, i.m. on days 0, 14 and 28. Among these, four groups (one group per serotype of each were subsequently challenged 3 weeks after the last boost with dengue virus (DENV serotypes 1-4 (100 LD50, 20 µl intracerebrally to determine vaccine efficacy. The fifth group of each was used as a control. The PBS immunized group was used as mock control. Serum samples were collected before and after subsequent immunizations. EDIII fusion protein expression was determined by Western blot. Total protein concentration was measured by Bradford assay. Neutralizing antibodies were assessed by TCID50-CPE inhibition assay. Statistical analysis was performed using Stata/IC 10.1 software for Windows. One-way repeated measures ANOVA and Mann-Whitney test were used for neutralizing antibody analysis and vaccine efficacy, respectively. Results: The recombinant EDIII fusion protein was expressed adequately in transfected 293T cells. Total protein concentration was almost 3 times more than the control. Vaccine candidate induced neutralizing antibodies against all four DENV serotypes with a notable increase after subsequent boosters. Vaccine efficacy was 83.3% (DENV-1, -3, -4 and 50% (DENV-2. Conclusion: Our results suggest that vaccine is immunogenic and protective; however, further studies are required to improve the immunogenicity particularly against DENV-2.

  7. A simplified ultrafiltration method for determination of serum free cortisol

    International Nuclear Information System (INIS)

    MacMahon, W.; Sgoutas, D.

    1983-01-01

    The authors describe the suitability of the Amicon MPS-1 centrifugal ultrafiltration device and the YMB membrane for measuring free cortisol in serum. The method combines two independent assays: total cortisol and the ultrafiltrate fraction of added [ 3 H]cortisol. The unbound fraction is determined in 0.25-0.30 ml of ultrafiltrate collected from 0.6 to 1 ml of serum that has been equilibrated with [ 3 H]cortisol at 37 0 C for 20 min. The assay is rapid (less than 1 h), practical (no more than 0.6 ml of serum is necessary) and repeatable (CV: 3.8% within-assay and 12.2% in different assays). Error introduced in free cortisol measurement due to dilution effects in dialysis is systematically defined, and the effect of tracer purity on the ultrafiltration method is examined. Dialyzed sera from normal men and women, from patients with Cushing's disease and adrenal insufficiency, and from pregnant women gave ultrafiltration results that accurately duplicated those obtained by previous dialysis. (Auth.)

  8. Assay of vitamin B12

    International Nuclear Information System (INIS)

    Tovey, K.C.; Carrick, D.T.

    1982-01-01

    A radioassay is described for vitamin B12 which involves denaturing serum protein binding proteins with alkali. In the denaturation step a dithiopolyol and cyanide are used and in the intrinsic factor assay step a vitamin B12 analogue such as cobinamide is used to bind with any remaining serum proteins. The invention also includes a kit in which the dithiopolyol is provided in admixture with the alkali. The dithiopolyol may be dithiothreitol or dithioerythritol. (author)

  9. Radioisotopic 51Cr-leukocyte adherence inhibition (LAI) assay. I

    International Nuclear Information System (INIS)

    Tsang, P.H.; Tangnavarad, K.; Lesnick, G.; Holland, J.F.; Bekesi, J.G.; Perloff, M.

    1980-01-01

    A simplified radioisotopic leukocyte adherence inhibition assay ( 51 Cr-LAI assay) was used to determine tumor-directed immune responses in patients with cancer of the breast. Essential steps in development of this assay are the standardization of conditions for optimal 51 Cr uptake by peripheral blood lymphocytes (PBL) and the inclusion of autologous or normal AB serum in the incubation media. A dextrose salt mixture (GNK) was found to enhance intracellular uptake of 51 Cr significantly (8-fold) without affecting viability of the cells or without causing selective loss of lymphocyte subpopulations. The presence of 10% autologous or normal AB serum prevented non-specific LAI responses to unrelated tumor antigens. Experimental results are presented and it is seen that this short term (4 h) 51 Cr-LAI assay provides reproducible and specific results analogous to those using tube-LAI assay. The test has the advantages of being accurate, sensitive and free from technical bias. (Auth.)

  10. Ethamsylate (Dicynone) interference in determination of serum creatinine, uric acid, triglycerides, and cholesterol in assays involving the Trinder reaction; in vivo and in vitro.

    Science.gov (United States)

    Dastych, Milan; Wiewiorka, Ondrej; Benovská, Miroslava

    2014-01-01

    The aim of our research was the quantification of interfering properties of the haemostatic drug Dicynone (ethamsylate) in serum creatinine, uric acid, cholesterol, and triglyceride assays using the Trinder reaction. Blood from patients was collected before and 15 minutes after administration of 500 mg Dicynone dose i.v. and the above mentioned analytes were quantified using Roche assays (Cobas 8000). In our in vitro experiment, we measured concentrations of the analytes in pooled serum aliquots with final concentrations of Dicynone additions 0, 30, 60, 150, and 300 mg/L. Aliquots with 60 mg/L Dicynone were also measured at 2, 6, and 8 hours after initial measurement when stored in 22 degrees C and 4 degrees C for comparison. Concentrations of the measured analytes in samples from patients administered with a 500 mg dose of Dicynone were lower in all cases (n = 10) when compared to values in samples taken immediately before treatment. The in vitro samples showed that considerable negative interference occurred even with the low concentrations of Dicynone additions (30 and 60 mg/L), showing the strongest negative interference in creatinine values, followed by uric acid, triglycerides, and cholesterol. Using in vitro samples, we showed strong time and temperature dependence on Dicynone interference. We found and proved significant negative interference of the drug Dicynone (ethamsylate) in the clinical analysis of blood using in vivo and in vitro experiments. Furthermore, we observed a change of this effect in serum matrix over time and at different storage temperatures.

  11. Development and characterization of neutralizing monoclonal antibodies against canine distemper virus hemagglutinin protein.

    Science.gov (United States)

    Bi, Zhenwei; Xia, Xingxia; Wang, Yongshan; Mei, Yongjie

    2015-04-01

    Canine distemper virus (CDV) causes a serious multisystemic disease in dogs and other carnivora. Hemagglutinin (H) protein-specific antibodies are mainly responsible for protective immunity against CDV infection. In the present study, six neutralizing MAbs to the H protein of CDV were newly obtained and characterized by immunizing BALB/c mice with a recent Chinese field isolate. Competitive binding inhibition assay revealed that they recognized four distinct antigenic regions of the H protein. Immunofluorescence assay and western blotting showed that all MAbs recognize the conformational rather than the linear epitopes of the H protein. Furthermore, in immunofluorescence and virus neutralization assays, two of the MAbs were found to react only with the recent Chinese field isolate and not with older CDV strains, including vaccine strain Onderstepoort, indicating there are neutralization-related antigenic variations between the recent Chinese field isolate and the older CDV strains examined in this study. The newly established MAbs are useful for differentiating the expanding CDV strains and could be used in immunotherapy and immunodiagnosis against infection with CDV. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.

  12. The HIV-1 V3 domain on field isolates: participation in generation of escape virus in vivo and accessibility to neutralizing antibodies

    DEFF Research Database (Denmark)

    Arendrup, M; Akerblom, L; Heegaard, P M

    1995-01-01

    The V3 domain is highly variable and induces HIV neutralizing antibodies (NA). Here we addressed the issues of 1) the participation of mutations in V3 in generation of neutralization resistant escape virus in vivo and 2) the applicability of synthetic V3 peptides corresponding to field isolates...... to induce neutralizing immune sera. Seven peptides corresponding to the V3 region of primary and escape virus from 3 HIV-1 infected patients were synthesized and used for antibody (Abs) studies and immunizations. The anti-V3 Abs titre in patient serum was generally low against peptides corresponding...... to autologous virus isolated later than the serum sample in contrast to the titre against peptides corresponding to virus isolated earlier than the serum sample. Furthermore, neutralizing anti-V3 monoclonal antibodies (MAbs) raised against V3 peptides from laboratory strains of HIV-1 showed distinct binding...

  13. Automated measurement of serum thyroxine with the ''AIRA II,'' as compared with competitive protein binding and radioimmunoassay

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.V.R.

    1978-01-01

    Two conventional serum thyroxine assays, run in separate laboratories, one by competitive protein binding and one by radioimmunoassay, were used to evaluate the automated ARIA II (Becton Dickinson Immunodiagnostics) serum thyroxine assay. Competitive protein binding as compared to ARIA II with 111 clinical serum samples gave a slope of 1.04 and a correlation coefficient of 0.94. The radioimmunoassay comparison to ARIA II with 53 clinical serum samples gave a slope of 1.05 and a correlation coefficient of 0.92. The ARIA II inter-assay coefficient of variation for 10 replicates of low, medium, and high thyroxine serum samples was 6.2, 6.0, and 2.9%, respectively, with an inter-assay coefficient of variation among 15 different assays of 15.5, 10.1, and 7.9%. The automated ARIA II, with a 2.2-min cycle per sample, gives results that compare well with those by manual methodology

  14. Evaluation of Brucella dipstick assay for the diagnosis of acute brucellosis

    NARCIS (Netherlands)

    Altuglu, Imre; Zeytinoğlu, Aysin; Bilgic, Altinay; Kamcioglu, Saniye; Karakartal, Guney; Smits, Henk

    2002-01-01

    The diagnostic value of the dipstick assay was evaluated by comparison with Rose Bengal (RB), serum aglutination tests (SAT) and 2 mercaptoethanol test (2-ME) on consecutive serum samples submitted because of suspicion of brucellosis. Serum samples of 232 patients with suspected brucellosis that

  15. Cytomegalovirus neutralization by hyperimmune and standard intravenous immunoglobulin preparations.

    Science.gov (United States)

    Planitzer, Christina B; Saemann, Marcus D; Gajek, Hartwig; Farcet, Maria R; Kreil, Thomas R

    2011-08-15

    Cytomegalovirus (CMV) remains one of the most important pathogens after transplantation, potentially leading to CMV disease, allograft dysfunction, acute, and chronic rejection and opportunistic infections. Immunoglobulin G (IgG) preparations with high antibody titers against CMV are a valuable adjunctive prevention and treatment option for clinicians and apart from standard intravenous immunoglobulin (IVIG), CMV hyperimmune preparations are available. The CMV antibody titer of these preparations is typically determined by Enzyme-linked immunosorbent assay (ELISA), also used for the selection of high titer plasma donors for the production of the CMV Hyperimmune product. However, CMV ELISA titers do not necessarily correlate with CMV antibody function which is determined by virus neutralization tests. CMV antibody titers were determined by both ELISA and virus neutralization assay and the IgG subclass distribution was compared between a CMV hyperimmune licensed in Europe and standard IVIG preparations. Although the expected high CMV IgG ELISA antibody titers were confirmed for three lots of a CMV hyperimmune preparation, the functionally more relevant CMV neutralizing antibody titers were significantly higher for 31 lots of standard IVIG preparations. Moreover, considerably lower IgG3 levels were found for the CMV hyperimmune preparation compared with standard IVIG preparations. The higher functional CMV neutralization titers of standard IVIG preparations and the better availability of these preparations, suggest that these products could be a valuable alternative to the CMV hyperimmune preparation.

  16. Heterotypic Protection and Induction of a Broad Heterotypic Neutralization Response by Rotavirus-Like Particles

    Science.gov (United States)

    Crawford, Sue E.; Estes, Mary K.; Ciarlet, Max; Barone, Christopher; O’Neal, Christine M.; Cohen, Jean; Conner, Margaret E.

    1999-01-01

    The recognition that rotaviruses are the major cause of life-threatening diarrheal disease and significant morbidity in young children has focused efforts on disease prevention and control of these viruses. Although the correlates of protection in children remain unclear, some studies indicate that serotype-specific antibody is important. Based on this premise, current live attenuated reassortant rotavirus vaccines include the four predominant serotypes of virus. We are evaluating subunit rotavirus vaccines, 2/6/7-VLPs and 2/4/6/7-VLPs, that contain only a single VP7 of serotype G1 or G3. In mice immunized parenterally twice, G3 virus-like particles (VLPs) induced a homotypic, whereas G1 VLPs induced a homotypic and heterotypic (G3) serum neutralizing immune response. Administration of three doses of G1 or G3 VLPs induced serum antibodies that neutralized five of seven different serotype test viruses. The inclusion of VP4 in the VLPs was not essential for the induction of heterotypic neutralizing antibody in mice. To confirm these results in another species, rabbits were immunized parenterally with two doses of 2/4/6/7-VLPs containing a G3 or G1 VP7, sequentially with G3 VLPs followed by G1 (G3/G1) VLPs, or with live or psoralen-inactivated SA11. High-titer homotypic serum neutralizing antibody was induced in all rabbits, and low-level heterotypic neutralizing antibody was induced in a subset of rabbits. The rabbits immunized with the G1 or G3/G1 VLPs in QS-21 were challenged orally with live G3 ALA rotavirus. Protection levels were similar in rabbits immunized with homotypic G3 2/4/6/7-VLPs, heterotypic G1 2/4/6/7-VLPs, or G3/G1 2/4/6/7-VLPs. Therefore, G1 2/4/6/7-VLPs can induce protective immunity against a live heterotypic rotavirus challenge in an adjuvant with potential use in humans. Following challenge, broad serum heterotypic neutralizing antibody responses were detected in rabbits parenterally immunized with G1, G3/G1, or G3 VLPs but not with SA11

  17. Evaluation of royal jelly as an alternative to fetal bovine serum in cell culture using cell proliferation assays and live cell imaging.

    Science.gov (United States)

    Musa, Marahaini; Nasir, Nurul Fatihah Mohamad; Thirumulu, Kannan Ponnuraj

    2014-01-01

    Royal jelly is a nutritious substance produced by the young nurse bees and contains significant amounts of proteins which are important for cell growth and proliferation. The aim of this study was to evaluate the effect of royal jelly as an alternative to fetal bovine serum (FBS) in cell culture using cell proliferation assays and live cell imaging. MRC-5 cells were treated with various concentrations of royal jelly extract in MTT assay. The control groups were comprised of Alpha-Minimal Essential Medium (α-MEM) alone and α-MEM with 10% FBS. Subsequently, the cell proliferation was studied for 10 days using Alamar Blue assay and live cell imaging from 48 to 72 h. The population doubling time (PDT) was determined using trypan blue assay after live cell imaging. In MTT assay, 0.156 and 0.078 mg/ml of royal jelly produced higher cell viability compared to positive control group but were not significantly different (P > 0.05). In the Alamar Blue assay, 0.156 and 0.078 mg/ml of royal jelly produced greater percentage of reduction at day 3 even though no significant difference was found (P > 0.05). Based on live cell imaging, the PDT for positive, negative, 0.156 and 0.078 mg/ml of royal jelly groups were 29.09, 62.50, 41.67 and 41.67 h respectively. No significant difference was found in the PDT between all the groups (P > 0.05). Royal jelly does not exhibit similar ability like FBS to facilitate cell growth under the present test conditions.

  18. Impact of host cell variation on the neutralization of HIV-1 in vitro

    NARCIS (Netherlands)

    Polonis, Victoria R.; Schuitemaker, Hanneke; Bunnik, Evelien M.; Brown, Bruce K.; Scarlatti, Gabriella

    2009-01-01

    PURPOSE OF REVIEW: In this review we present current advances in our understanding of HIV-1 neutralization assays that employ primary cell types, as compared with those that utilize cell lines and the newer, more standardized pseudovirus assays. A commentary on the challenges of standardizing

  19. Detection of Serum Thermolabile β-2 Macroglycoprotein (Hakata Antigen) by Enzyme-Linked Immunosorbent Assay Using Polysaccharide Produced by Aerococcus viridans

    Science.gov (United States)

    Tsujimura, Mitsushi; Ishida, Chuzo; Sagara, Yasuko; Miyazaki, Takashi; Murakami, Koichi; Shiraki, Hiroshi; Okochi, Kazuo; Maeda, Yoshiaki

    2001-01-01

    Although a serum thermolabile β-2 macroglycoprotein (TMG) may play a role in host defense as a lectin, little is known of its related physiological functions, mainly due to a lack of appropriate methods for tracing the functions of TMG. We identified a polysaccharide from Aerococcus viridans, PSA, which reacts with TMG, and based on this finding, we developed an enzyme-linked immunosorbent assay to trace the functions of TMG. Using ethanol precipitation and DEAE-Sepharose and Sephacryl S-400 column chromatographies, we isolated PSA from cultured medium of A. viridans, and it exhibited specific binding against TMG in blood samples. In sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), the isolated PSA showed ladder bands that implied the existence of repeating units composed of d-glucose, N-acetyl-d-glucosamine, d-mannose, and d-xylose, as confirmed by gas chromatography-mass spectrometry. SDS-PAGE and immunochemical analysis, using rabbit anti-TMG antibody, showed that PSA specifically binds solely to intact serum TMG but not to TMG heated at 56°C for 30 min, a condition under which antigenicity is lost. TMG in serum samples bound to PSA in a dose-dependent manner, and this binding was clearly suppressed by addition of PSA. These observations indicate that PSA is a useful adsorbent to TMG and can be used to develop appropriate methods for tracing the functions of TMG. PMID:11238239

  20. Production of high titre antibody response against Russell's viper venom in mice immunized with ethanolic extract of fruits of Piper longum L. (Piperaceae) and piperine.

    Science.gov (United States)

    Shenoy, P A; Nipate, S S; Sonpetkar, J M; Salvi, N C; Waghmare, A B; Chaudhari, P D

    2014-01-15

    Piper longum L. fruits have been traditionally used against snakebites in north-eastern and southern region of India. The aim of the study was to assess the production of antibody response against Russell's viper venom in mice after prophylactic immunization with ethanolic extract of fruits of Piper longum L. and piperine. The mice sera were tested for the presence of antibodies against Russell's viper venom by in vitro lethality neutralization assay and in vivo lethality neutralization assay. Polyvalent anti-snake venom serum (antivenom) manufactured by Haffkine Bio-Pharmaceutical Corporation Ltd. was used as standard. Further confirmation of presence of antibodies against the venom in sera of mice immunized with PLE and piperine was done using indirect enzyme-linked immunosorbent assay (ELISA) and double immunodiffusion test. Treatment with PLE-treated mice serum and piperine-treated mice serum was found to inhibit the lethal action of venom both in the in vitro lethality neutralization assay and in vivo lethality neutralization assay. ELISA testing indicated that there were significantly high (pPiper longum and piperine produced a high titre antibody response against Russell's viper venom in mice. The antibodies against PLE and piperine could be useful in antivenom therapy of Russell's viper bites. PLE and piperine may also have a potential interest in view of the development of antivenom formulations used as antidote against snake bites. Copyright © 2013 Elsevier GmbH. All rights reserved.

  1. A Microplate Growth Inhibition Assay for Screening Bacteriocins against Listeria monocytogenes to Differentiate Their Mode-of-Action

    Directory of Open Access Journals (Sweden)

    Paul Priyesh Vijayakumar

    2015-06-01

    Full Text Available Lactic acid bacteria (LAB have historically been used in food fermentations to preserve foods and are generally-recognized-as-safe (GRAS by the FDA for use as food ingredients. In addition to lactic acid; some strains also produce bacteriocins that have been proposed for use as food preservatives. In this study we examined the inhibition of Listeria monocytogenes 39-2 by neutralized and non-neutralized bacteriocin preparations (Bac+ preps produced by Lactobacillus curvatus FS47; Lb. curvatus Beef3; Pediococcus acidilactici Bac3; Lactococcus lactis FLS1; Enterococcus faecium FS56-1; and Enterococcus thailandicus FS92. Activity differences between non-neutralized and neutralized Bac+ preps in agar spot assays could not readily be attributed to acid because a bacteriocin-negative control strain was not inhibitory to Listeria in these assays. When neutralized and non-neutralized Bac+ preps were used in microplate growth inhibition assays against L. monocytogenes 39-2 we observed some differences attributed to acid inhibition. A microplate growth inhibition assay was used to compare inhibitory reactions of wild-type and bacteriocin-resistant variants of L. monocytogenes to differentiate bacteriocins with different modes-of-action (MOA whereby curvaticins FS47 and Beef3, and pediocin Bac3 were categorized to be in MOA1; enterocins FS92 and FS56-1 in MOA2; and lacticin FLS1 in MOA3. The microplate bacteriocin MOA assay establishes a platform to evaluate the best combination of bacteriocin preparations for use in food applications as biopreservatives against L. monocytogenes.

  2. A Microplate Growth Inhibition Assay for Screening Bacteriocins against Listeria monocytogenes to Differentiate Their Mode-of-Action.

    Science.gov (United States)

    Vijayakumar, Paul Priyesh; Muriana, Peter M

    2015-06-11

    Lactic acid bacteria (LAB) have historically been used in food fermentations to preserve foods and are generally-recognized-as-safe (GRAS) by the FDA for use as food ingredients. In addition to lactic acid; some strains also produce bacteriocins that have been proposed for use as food preservatives. In this study we examined the inhibition of Listeria monocytogenes 39-2 by neutralized and non-neutralized bacteriocin preparations (Bac+ preps) produced by Lactobacillus curvatus FS47; Lb. curvatus Beef3; Pediococcus acidilactici Bac3; Lactococcus lactis FLS1; Enterococcus faecium FS56-1; and Enterococcus thailandicus FS92. Activity differences between non-neutralized and neutralized Bac+ preps in agar spot assays could not readily be attributed to acid because a bacteriocin-negative control strain was not inhibitory to Listeria in these assays. When neutralized and non-neutralized Bac+ preps were used in microplate growth inhibition assays against L. monocytogenes 39-2 we observed some differences attributed to acid inhibition. A microplate growth inhibition assay was used to compare inhibitory reactions of wild-type and bacteriocin-resistant variants of L. monocytogenes to differentiate bacteriocins with different modes-of-action (MOA) whereby curvaticins FS47 and Beef3, and pediocin Bac3 were categorized to be in MOA1; enterocins FS92 and FS56-1 in MOA2; and lacticin FLS1 in MOA3. The microplate bacteriocin MOA assay establishes a platform to evaluate the best combination of bacteriocin preparations for use in food applications as biopreservatives against L. monocytogenes.

  3. Neutralization epitopes on HIV pseudotyped with HTLV-I: Conservation of carbohydrate Epitopes

    DEFF Research Database (Denmark)

    Sørensen, A M; Nielsen, C; Arendrup, M

    1994-01-01

    One mechanism for expanding the cellular tropism of human immunodeficiency virus (HIV) in vitro is through formation of phenotypically mixed particles (pseudotypes) with human T lymphotropic virus type I (HTLV-I). In this study we found that pseudotypes allow penetration of HIV particles into CD4......-negative cells, previously nonsusceptible to HIV infection. The infection of CD4-negative cells with pseudotypes could be blocked with anti-HTLV-I serum but failed to be significantly inhibited with anti-HIV serum or a V3-neutralizing anti-gp120 monoclonal antibody. This may represent a possibility...... by cell-free pseudotypes in CD4-negative cells. We suggest that although viral cofactors might expand the tropism of HIV in vivo, HIV and HTLV-I seem to induce common carbohydrate neutralization epitopes....

  4. Neutralization epitopes on HIV pseudotyped with HTLV-I: conservation of carbohydrate epitopes

    DEFF Research Database (Denmark)

    Sørensen, A M; Nielsen, C; Arendrup, M

    1994-01-01

    One mechanism for expanding the cellular tropism of human immunodeficiency virus (HIV) in vitro is through formation of phenotypically mixed particles (pseudotypes) with human T lymphotropic virus type I (HTLV-I). In this study we found that pseudotypes allow penetration of HIV particles into CD4......-negative cells, previously nonsusceptible to HIV infection. The infection of CD4-negative cells with pseudotypes could be blocked with anti-HTLV-I serum but failed to be significantly inhibited with anti-HIV serum or a V3-neutralizing anti-gp120 monoclonal antibody. This may represent a possibility...... by cell-free pseudotypes in CD4-negative cells. We suggest that although viral cofactors might expand the tropism of HIV in vivo, HIV and HTLV-I seem to induce common carbohydrate neutralization epitopes....

  5. Neutralizing antibodies in cats infected with feline immunodeficiency virus.

    NARCIS (Netherlands)

    F. Tozzini; D. Matteucci; P. Bandecchi; F. Baldinotti; C.H.J. Siebelink (Kees); A.D.M.E. Osterhaus (Albert); M. Bendinelli

    1993-01-01

    textabstractSera from cats experimentally infected with five isolates of feline immunodeficiency virus (FIV) from various geographical regions and from FIV enzyme-linked immunosorbent assay-seropositive field cats from four European countries neutralized the Petaluma strain of FIV (FIV-P),

  6. Multiplex assay (Mikrogen recomBead) for detection of serum IgG and IgM antibodies to 13 recombinant antigens of Borrelia burgdorferi sensu lato in patients with neuroborreliosis

    DEFF Research Database (Denmark)

    Dessau, Ram Benny; Møller, Jens K.; Kolmos, Birte

    2015-01-01

    A multiplex-bead-based assay for the detection of serum antibodies to Borrelia burgdorferi sensu lato was evaluated. The assay contained 13 different antigens in both the IgG and the IgM assay; thus, a total of 26 measurement results were available from each sample. A total of 49 Danish patients......, the construction of a diagnostic score, evaluation of the scoring method using an independent dataset and an assessment of the analytical quality of the multiplex assay. The VlsE IgG had the highest diagnostic value with an AUC (area under the curve) of 96% on the receiver operating characteristic curve. The Osp......C IgM had AUCs just above 80%. All the other antigens had both low quantitative reactivity and lower contrast in the patients with LNB compared to controls. The diagnostic value of the assay may be improved by using a logistic model giving a sensitivity of 90 and 79% for the specificities at 92 and 98...

  7. Microchemiluminescent assay system

    Energy Technology Data Exchange (ETDEWEB)

    Kiel, J.L.

    1986-04-09

    The patent concerns a microchemiluminescent assay system, which can be used to detect ionizing radiation, heat or specific substances. The method involves the use of a complex formed from serum albumin and a luminescer which, in the presence of ionizing radiation (heat, or a specific analyte), will emit light in an amount proportional to the amount of radiation, etc. (U.K.).

  8. Evaluation of an enzyme-linked immunosorbent assay for determination of porcine haptoglobin

    DEFF Research Database (Denmark)

    Petersen, H. H.; Nielsen, J. P.; Jensen, A.L.

    2001-01-01

    An enzyme-linked immunosorbent assay for quantification of haptoglobin in porcine serum was evaluated. Tbe detection limit when expressed as the estimated concentration of a blank sample was 0.0003 mg/ml. The precision of the assay was acceptable with intra-assay coefficients of variation below 4...... % and inter-assay coefficient of variation below 5 % for serum concentrations ranging from 1.0 mg/ml and above. For samples with a concentration below 0.8 mg/ml, the inter-assay coefficient of variation was above 10 %. The assay maintained linearity under dilution. Recovery was proportional. Haemolysis.......2. The maximum allowable analytical imprecision was 2.6 % and the maximum analytical inaccuracy was 9.9 %. The number of samples required to determine, the true haptoglobin value in an individual pig when accounting for the day-to-day fluctuation was 5. In conclusion, the haptoglobin assay was found...

  9. Prostate-specific antigen superior serum marker for prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, J A; Allen, M A; Keane, T; Duffy, J J

    1987-05-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM/sup R/) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable.

  10. Prostate-specific antigen superior serum marker for prostatic carcinoma

    International Nuclear Information System (INIS)

    Heaney, J.A.; Allen, M.A.; Keane, T.; Duffy, J.J.

    1987-01-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM R ) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable. (author)

  11. Comparison of antibody responses to human papillomavirus vaccination as measured by three assays

    Directory of Open Access Journals (Sweden)

    Hilary Ann Robbins

    2014-01-01

    Full Text Available Background: Different assays, including the competitive Luminex immunoassay (cLIA, secreted alkaline phosphatase neutralization assay (SEAP-NA, and virus-like particle-based ELISA, are commonly used to measure antibody responses after human papillomavirus (HPV vaccination. Direct assay comparisons aid interpretation of immunogenicity data evaluated by different assays. Methods: We compared cLIA to SEAP-NA and ELISA among 51 HPV16/18-vaccinated women enrolled in the Costa Rica Vaccine Trial. We tested replicate serum samples collected at months 0, 1, and 12 by HPV16/18 cLIA, SEAP-NA, and ELISA. For a subset (N=10, we further tested month 24 and 36 samples. We calculated seroprevalence estimates and Spearman rank correlation coefficients comparing cLIA to SEAP-NA and ELISA.Results: After one vaccine dose, seroprevalence by SEAP-NA and ELISA was 100% (both HPV16 and HPV18, and by cLIA was 96% (95% CI 87%-100% for HPV16 and 71% (95% CI 56%-83% for HPV18. Seroprevalence was 100% by all assays after 3 doses. Correlation between assays was high after one vaccine dose (cLIA/SEAP-NA ρ=0.91 (HPV16 and ρ=0.86 (HPV18; cLIA/ELISA ρ=0.84 (HPV16 and ρ=0.74 (HPV18; all p<0.001 and remained high through month 36. Ratios of mean antibody levels to seropositivity cutoffs at month 36 were lower for cLIA than for SEAP-NA or ELISA, particularly for HPV18 (HPV18 ratio for cLIA 1.9, SEAP-NA 3.5, ELISA 3.4.Conclusion: Though correlation between cLIA and SEAP-NA/ELISA is high and stable after vaccination, the assays differ in scale and sensitivity, with notable differences after 1 vaccine dose and for HPV18. Our results demonstrate that comparisons of antibody responses to HPV vaccination measured by different assays are approximate, and must consider biological and technical differences between assays.

  12. MERS Coronavirus Neutralizing Antibodies in Camels, Eastern Africa, 1983-1997

    NARCIS (Netherlands)

    Müller, Marcel A; Corman, Victor Max; Jores, Joerg; Meyer, Benjamin; Younan, Mario; Liljander, Anne; Bosch, Berend-Jan; Lattwein, Erik; Hilali, Mosaad; Musa, Bakri E; Bornstein, Set; Drosten, Christian

    2014-01-01

    To analyze the distribution of Middle East respiratory syndrome coronavirus (MERS-CoV)-seropositive dromedary camels in eastern Africa, we tested 189 archived serum samples accumulated during the past 30 years. We identified MERS-CoV neutralizing antibodies in 81.0% of samples from the main

  13. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  14. Detection of microbial translocation in HIV and SIV infection using the Limulus amebocyte lysate assay is masked by serum and plasma.

    Directory of Open Access Journals (Sweden)

    Ashwin Balagopal

    Full Text Available Microbial translocation (MT is thought to be a major contributor to the pathogenesis of HIV-related immune activation, and circulating lipopolysaccharide (LPS from gram-negative bacteria is the principle measurement of this process. However, related research has been impeded by inconsistent LPS test results.Specimens were obtained from HIV-infected adults enrolled in the PEARLS study (ACTG A5175 and HIV-HCV co-infected participants enrolled in a study of liver disease staging using MRI elastography. Pig-tailed macaque specimens were obtained from SIV-infected and -uninfected animals. Samples were tested for LPS using the LAL assay with diazo-coupling modifications to improve sensitive detection.When exogenous LPS was added to macaque plasma, >25% inhibition of LPS detection was found in 10/10 (100% samples at 20% plasma concentration compared to control; in contrast 5/10 (50% samples at 2% plasma concentration (p = 0.07 and 0/10 (0% at 0.1% plasma concentration (p = 0.004 showed >25% inhibition of LPS detection. Similarly, when LPS was added to human serum, >25% inhibition of LPS detection was found in 5/12 (42% of samples at 2% serum concentration compared to control, while 0/12 (0% of samples in 0.1% serum showed >25% inhibition of LPS detection (p = 0.07. Likewise, LPS detection in human sera without exogenous LPS was improved by dilution: LPS was detected in 2/12 (17% human samples in 2% serum, ranging from 3,436-4,736 pg/mL, compared to 9/12 (75% samples in 0.1% serum, ranging from 123 pg/mL -60,131 pg/mL (p = 0.016. In a separate validation cohort of HIV-HCV co-infected participants sampled at two different times on the same day, LPS measured in 0.2% plasma and with diazo-coupling was closely correlated between the first and second samples (R = 0.66, p<0.05.Undiluted serum and plasma mask LPS detection. The extent of MT may be substantially underestimated.

  15. ADAM12: a novel first-trimester maternal serum marker for Down syndrome

    DEFF Research Database (Denmark)

    Laigaard, Jennie; Sørensen, Tina; Fröhlich, Camilla

    2003-01-01

    levels decrease markedly during pregnancy. ADAM12 (A disintegrin and metalloprotease) is an IGFBP-3 and IGFBP-5 protease and is present in human pregnancy serum. The goal of this study was to determine whether ADAM12 concentration in maternal serum is a useful indicator of foetal health. METHODS: We......OBJECTIVES: The concentration of bioavailable insulin-like growth factor (IGF) I and II is important to foetal growth. It is regulated by insulin-like growth factor binding proteins (IGFBP) 1 through 6. Proteolytic cleavage of IGFBP-3 takes place in human pregnancy serum; accordingly, IGFBP-3 serum...... developed an enzyme-linked immunosorbent assay (ELISA) for the quantification of ADAM12 in serum. The assay range was 42 to 667 micro g/L. Recombinant ADAM12 was used as the standard for calibration. RESULTS: We found that ADAM12 was highly stable in serum. Serum concentration increased from 180 micro g...

  16. Human serum albumin binding assay based on displacement of a non selective fluorescent inhibitor.

    Science.gov (United States)

    Thorarensen, Atli; Sarver, Ronald W; Tian, Fang; Ho, Andrea; Romero, Donna L; Marotti, Keith R

    2007-08-15

    In this paper, we describe a fluorescent antibacterial analog, 6, with utility as a competition probe to determine affinities of other antibacterial analogs for human serum albumin (HSA). Analog 6 bound to HSA with an affinity of 400+/-100 nM and the fluorescence was environmentally sensitive. With 370 nm excitation, environmental sensitivity was indicated by a quenching of the 530 nm emission when the probe bound to HSA. Displacement of dansylsarcosine from HSA by 6 indicated it competed with compounds that bound at site II (ibuprofen binding site) on HSA. Analog 6 also shifted the NMR peaks of an HSA bound oleic acid molecule that itself was affected by compounds that bound at site II. In addition to binding at site II, 6 interacted at site I (warfarin binding site) as indicated by displacement of dansylamide and the shifting of NMR peaks of an HSA bound oleic acid molecule affected by warfarin site binding. Additional evidence for multiple site interaction was discovered when a percentage of 6 could be displaced by either ibuprofen or phenylbutazone. A competition assay was established using 6 to determine relative affinities of other antibacterial inhibitors for HSA.

  17. Prevalence of measles neutralizing antibody in children under 15 ...

    African Journals Online (AJOL)

    The immune status of children under 15 years in the Southwestern region of Nigeria against measles virus was determined using the neutralization test with a view to assessing the herd immunity to the virus in these communities. A total of 256 serum samples collected from children were tested by the beta method of ...

  18. An improved assay for iduronate 2-sulphate sulphatase in serum and its use in the detection of carriers of the Hunter syndrome

    International Nuclear Information System (INIS)

    Archer, I.M.; Harper, P.S.; Wusteman, F.S.

    1981-01-01

    A more sensitive assay procedure has been developed for the enzyme iduronate 2-sulphate sulphatase which is deficient in the Hunter syndrome. The substrate is O-(α-L-idopyranosyluronic acid 2-sulphate)-(1 → 4)-2,5 anhydro-D-[ 3 H-1)mannitol 6-sulphate, which, after incubation, is separated from the product by ion-exchange chromatography on a micro-columnn of Dowex 1 X 2 (Cl - ). Serum analyses can be used to supplement those on hair roots in the detection of carriers of the Hunter syndrome. (Auth.)

  19. [Virus strain specific serum neutralizing antibodies in children and adolescents immunized with a Russian mumps vaccine].

    Science.gov (United States)

    Otrashevskaia, E V; Krasil'nikov, I V; Ignat'ev, G M

    2010-01-01

    Postvaccination immunity was studied in the children and teenagers without a history of clinical mumps infection, who had been immunized with the Leningrad-3 mumps vaccine. The level of specific lgG in ELISA and that and spectrum of their neutralizing activity against a vaccine strain and three heterologous mumps virus (MV) strains (genotypes A, C, and H) were measured. The investigation included 151 sera from the vaccinees aged 3 to 17 years, possessing the detectable specific IgG titers in ELISA and the detectable neutralizing titers against the vaccine strain. 97.4% of the vaccinees had neutralizing activity against 1-3 heterologous MV strains. A preponderance of neutralizing titers against heterologous MV strains by 1-log2 in some sera (6.5-32.5 depending on age) was most likely to suggest that the vaccinees' had been in contact with these virus strains in the past. In our investigation, a combination of positive IgG titers and neutralizing titers against the vaccine strain 2-log2 or higher provided the protection of the vaccinated children and teenagers against the symptomatic infection. There was a pronounced buster effect of the second immunization and a drop in the neutralizing activity of the sera from the vaccinated children and adolescents over time after the first and second immunization.

  20. Microculture Plaque Neutralization Test for California Group Arboviruses

    Science.gov (United States)

    Seawright, Gary L.; Harding, Gherry; Thomas, Frederick C.; Hanson, Robert P.

    1974-01-01

    A microculture plaque neutralization test is described for California-group arboviruses that is as precise and quantitative as the standard test conducted in 60-mm petri dishes. It was shown that there was no significant between-panel or between-day variation in determinations and that a single pipette could be used for all serum-dilution levels within a titration without inoculum carry-over effect. The experimental protocol and statistical methods used produce 50% neutralization end points that meet the assumptions of parametric statistics. This permits the power and versatility of the analysis of variance to be exploited in testing for treatment effects in serological and immunological studies with viruses. Images PMID:4216288

  1. Cloning of the first human anti-JCPyV/VP1 neutralizing monoclonal antibody: epitope definition and implications in risk stratification of patients under natalizumab therapy.

    Science.gov (United States)

    Diotti, Roberta Antonia; Mancini, Nicasio; Clementi, Nicola; Sautto, Giuseppe; Moreno, Guisella Janett; Criscuolo, Elena; Cappelletti, Francesca; Man, Petr; Forest, Eric; Remy, Louise; Giannecchini, Simone; Clementi, Massimo; Burioni, Roberto

    2014-08-01

    JC virus (JCPyV) has gained novel clinical importance as cause of progressive multifocal leukoencephalopathy (PML), a rare demyelinating disease recently associated to immunomodulatory drugs, such as natalizumab used in multiple sclerosis (MS) cases. Little is known about the mechanisms leading to PML, and this makes the need of PML risk stratification among natalizumab-treated patients very compelling. Clinical and laboratory-based risk-stratification markers have been proposed, one of these is represented by the JCPyV-seropositive status, which includes about 54% of MS patients. We recently proposed to investigate the possible protective role of neutralizing humoral immune response in preventing JCPyV reactivation. In this proof-of-concept study, by cloning the first human monoclonal antibody (GRE1) directed against a neutralizing epitope on JCPyV/VP1, we optimized a robust anti-JCPyV neutralization assay. This allowed us to evaluate the neutralizing activity in JCPyV-positive sera from MS patients, demonstrating the lack of correlation between the level of anti-JCPyV antibody and anti-JCPyV neutralizing activity. Relevant consequences may derive from future clinical studies induced by these findings; indeed the study of the serum anti-JCPyV neutralizing activity could allow not only a better risk stratification of the patients during natalizumab treatment, but also a better understanding of the pathophysiological mechanisms leading to PML, highlighting the contribution of peripheral versus central nervous system JCPyV reactivation. Noteworthy, the availability of GRE1 could allow the design of novel immunoprophylactic strategies during the immunomodulatory treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Development and characterization of a reverse genetic system for studying dengue virus serotype 3 strain variation and neutralization.

    Directory of Open Access Journals (Sweden)

    William B Messer

    Full Text Available Dengue viruses (DENV are enveloped single-stranded positive-sense RNA viruses transmitted by Aedes spp. mosquitoes. There are four genetically distinct serotypes designated DENV-1 through DENV-4, each further subdivided into distinct genotypes. The dengue scientific community has long contended that infection with one serotype confers lifelong protection against subsequent infection with the same serotype, irrespective of virus genotype. However this hypothesis is under increased scrutiny and the role of DENV genotypic variation in protection from repeated infection is less certain. As dengue vaccine trials move increasingly into field-testing, there is an urgent need to develop tools to better define the role of genotypic variation in DENV infection and immunity. To better understand genotypic variation in DENV-3 neutralization and protection, we designed and constructed a panel of isogenic, recombinant DENV-3 infectious clones, each expressing an envelope glycoprotein from a different DENV-3 genotype; Philippines 1982 (genotype I, Thailand 1995 (genotype II, Sri Lanka 1989 and Cuba 2002 (genotype III and Puerto Rico 1977 (genotype IV. We used the panel to explore how natural envelope variation influences DENV-polyclonal serum interactions. When the recombinant viruses were tested in neutralization assays using immune sera from primary DENV infections, neutralization titers varied by as much as ∼19-fold, depending on the expressed envelope glycoprotein. The observed variability in neutralization titers suggests that relatively few residue changes in the E glycoprotein may have significant effects on DENV specific humoral immunity and influence antibody mediated protection or disease enhancement in the setting of both natural infection and vaccination. These genotypic differences are also likely to be important in temporal and spatial microevolution of DENV-3 in the background of heterotypic neutralization. The recombinant and synthetic tools

  3. Radioassay for serum and red cell folate

    International Nuclear Information System (INIS)

    Longo, D.L.; Herbert, V.

    1976-01-01

    A simple, reliable assay for serum and red cell folate is described. It uses plain untreated liquid or powdered milk, requiring no special handling or purification, as binder. Such milk makes it possible to ignore endogenous serum folate binder, since crude (but not purified) milk contains a factor which releases folate from serum binder. It simplifies counting radioactivity by employing a gamma emitting isotope of pteroylglutamic acid (PGA), namely the 125 I-tyramide of PGA. Like the 3 H-PGA assay of Givas and Gutcho, it permits the use of stable PGA rather than unstable methyltetrahydrofolic acid (MeTHFA) standards, because it is carried out at pH 9.3, a pH at which milk folate binder is unable to distinguish PGA from MeTHFA, which is the predominant folate in human tissues. The equipment required to do the radioassay is present in most diagnostic chemistry laboratories. Results are essentially identical to the generally accepted Lactobacillus casei microbiologic method of folate assay, except that false low results are not produced in the radioassay by antibiotics, tranquilizers, and chemotherapeutic agents. Three caveats in its use are the relative instability of 125 I-PGA as compared to 3 H-PGA, the fact that various powdered milks differ widely in folate-binding capacity, and that only about 60 percent of commercially obtained skim or powdered milk preparations appear to contain the substance which splits folate from serum binder

  4. Studies on somatomedin A with special reference to its measurement by a radioreceptor assay

    International Nuclear Information System (INIS)

    Takano, K.

    1975-01-01

    A radioreceptor assay for somatomedin A was developed utilizing human placental membrane. This assay method is more sensitive and simpler than the chick bioassay and requires only 40μl of serum. It is not species specific. The level of somatomedin A in serum from different animals decrease with increased size of the animal species. (Auth.)

  5. Rapid microbiological assay of serum vitamin B 12 by electronic counter.

    Science.gov (United States)

    Stuart, J; Sklaroff, S A

    1966-01-01

    A new method of measuring the growth of Lactobacillus leichmannii is reported. Its adoption for the estimation of serum vitamin B(12) levels shortens the incubation period required to five hours at 45 degrees C. The method is compared statistically with a standard method of estimation, requiring incubation at 37 degrees C., by duplicate determinations on 106 hospital patients. The significance of the apparently decreased accuracy of the new method at low serum levels is discussed, and a re-appraisal of the optimum growth temperature of Lactobacillus leichmannii suggested.

  6. Levels of house dust mite-specific serum immunoglobulin E (IgE) in different cat populations using a monoclonal based anti-IgE enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Bexley, Jennifer; Hogg, Janice E; Hammerberg, Bruce; Halliwell, Richard E W

    2009-10-01

    Levels of serum immunoglobulin E (IgE) specific for the house dust mites (HDMs) Dermatophagoides farinae (DF) and Dermatophagoides pteronyssinus (DP) in 58 cats with clinical signs suggestive of atopic dermatitis (allergic dermatitis cats), 52 cats with no history of allergic or immunological disease (nonallergic cats) and 26 specific pathogen-free (SPF) cats were measured using a monoclonal anti-IgE enzyme-linked immunosorbent assay. Reactivity to both native and reduced HDM allergens was compared. SPF cats had significantly lower levels of HDM-specific serum IgE than cats with allergic dermatitis and nonallergic cats. The difference in levels of HDM-specific IgE in the serum of cats with allergic dermatitis and nonallergic cats was significant for native DF allergen, but not for native DP allergen or reduced HDM allergens. The results suggest that DF in its native form may be a significant allergen in cats with allergic dermatitis. The clinical relevance of these reactions, however, remains to be proven.

  7. Inhibition of Neutral Red Photolysis with Different Antioxidants

    Directory of Open Access Journals (Sweden)

    Zlatan Rimpapa

    2007-02-01

    Full Text Available Neutral red is a dye the azine structure which has been used as an acido-base indicator and a dye in histochemistry. In 1960 Goldhaber introduced Neutral red into the medium of resorbing bone cultures to localize the osteoclast in the living cultures. Using time-lapse microcinematography in order to follow the osteoclasts, he reported excellent contrast could be obtained with Neutral red due to the avidity of osteoclasts for this dye. Unfortunately, however, the photodynamic effect resulting from subsequent exposure of these cultures to light precluded this approach, and again in 1963. it was observed that the death of the osteoclasts was probably due to a photodynamic effect related to the dye in the cell, the presence of oxygen and the frequent exposure of light by our time-lapse photography. VIS and UV irradiation induced photolysis of Neutral red, and from Neutral red cation produced with photons a Neutral red radical. This Neutral red radical can be inhibited with action of an antioxidant, such as melatonin, glutathione, ascorbic acid, E vitamin, etc. We developed an assay with Neutral redphotolysis which utilizes a VIS and UV irradiation technique for quantification the inhibition of photolysis with action of an antioxidant. In this method Neutral red acts double, as a free radical generator and as a photosensitizer.

  8. Identification of high-affinity anti-IL-1 α autoantibodies in normal human serum as an interfering substance in a sensitive enzyme-linked immunosorbent assay for IL-1 α

    International Nuclear Information System (INIS)

    Mae, N.; Liberato, D.J.; Chizzonite, R.; Satoh, H.

    1991-01-01

    A highly reproducible, sensitive, and specific sandwich enzyme-linked immunosorbent assay (ELISA) for recombinant human IL-1 α (rhIL-1 alpha) has been developed. Results from this ELISA have demonstrated that the concentration of rhIL-1 α added to normal human serum (NHS) decreased by 16.3% after 3 h and 24.9% after 6 h at room temperature. Molecular exclusion column chromatography with Sephacryl S-300 HR revealed that 125I-labeled IL-1 α added to normal human serum rapidly formed higher molecular weight complexes without indication of proteolytic degradation. The observed reduction in immunoreactivity was correlated with this protein complex formation and accounted for the apparent instability of rhIL-1 α in NHS. Immunoblot analysis indicated that the molecular weight of the binding protein was 150-160K, and the IL-1 α binding activity was removed and recovered from NHS by Protein-G affinity chromatography; indicating that the binding protein was IL-1 α-specific IgG. The binding of 125I-labeled IL-1 α to the serum binding proteins could be inhibited by unlabeled IL-1 alpha (IC50 = 7.4 x 10(-11) M) but not by unlabeled IL-1 β. Kinetic analysis with 125I-labeled IL-1 alpha revealed that the average binding affinity of these IL-1 α-specific IgGs was 4.7 x 10(10) M-1. These results suggest that these autoantibodies may interfere with the detection of IL-1 α in human serum by various assay systems and also could be a regulator of circulating IL-1 α

  9. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  10. Use of the serum anti-Müllerian hormone assay as a surrogate for polycystic ovarian morphology: impact on diagnosis and phenotypic classification of polycystic ovary syndrome.

    Science.gov (United States)

    Fraissinet, Alice; Robin, Geoffroy; Pigny, Pascal; Lefebvre, Tiphaine; Catteau-Jonard, Sophie; Dewailly, Didier

    2017-08-01

    Does the use of the serum anti-Müllerian hormone (AMH) assay to replace or complement ultrasound (U/S) affect the diagnosis or phenotypic distribution of polycystic ovary syndrome (PCOS)? Combining U/S and the serum AMH assay to define polycystic ovarian morphology (PCOM) diagnoses PCOS (according to the Rotterdam classification) in more patients than definitions using one or the other of these indicators exclusively. Since 2003, PCOM, as defined by U/S, is one of the three diagnostic criteria for PCOS. As it is closely correlated with follicle excess seen at U/S, an excessive serum AMH level could be used as a surrogate for PCOM. Single-center retrospective study from a database of prospectively collected clinical, laboratory and ultrasound data from patients referred for oligo-anovulation (OA) and/or hyperandrogenism (HA) between January 2009 and January 2016. The standard Rotterdam classification for PCOS was tested against two modified versions that defined PCOM by either excessive serum AMH level alone (AMH-only) or a combination (i.e. 'and/or') of the latter and U/S. The PCOS phenotypes were defined as A (full phenotype, OA+HA+PCOM), B (OA+HA), C (HA+PCOM) and D (OA+PCOM). PCOS was more frequently diagnosed when PCOM was defined as the combination 'positive U/S' and/or 'positive AMH' (n = 639) than by either only U/S-only (standard definition, n = 612) or by AMH-only (n = 601). With this combination, PCOM was recognized in 637 of the 639 cases that met the Rotterdam classification, and phenotype B practically disappeared. In this population, U/S and AMH markers were discordant for PCOM in 103 (16.1%) cases (9% U/S-only, 7.1% AMH-only, P = 0.159). The markers used had no other significant impact on the phenotypic distribution (except for phenotype B). However, the percentage of cases positive by U/S-only was significantly higher in phenotype D than in phenotype A (14.1% vs. 5.8%, P < 0.05). Furthermore, in the discordant cases, plasma LH levels were

  11. Continuous recording of long-chain acyl-coenzyme A synthetase activity using fluorescently labeled bovine serum albumin

    DEFF Research Database (Denmark)

    Demant, Erland J.F.; Nystrøm, Birthe T.

    2001-01-01

    acyl-Coenzyme A, synthetase, activity assay, fluorescence recording, fatty acid probe, serum albumin, hydroxycoumarin, detergent, micelles, Pseudomonas fragi, rat liver microsomes......acyl-Coenzyme A, synthetase, activity assay, fluorescence recording, fatty acid probe, serum albumin, hydroxycoumarin, detergent, micelles, Pseudomonas fragi, rat liver microsomes...

  12. Reassessing the reliability of the salivary cortisol assay for the diagnosis of Cushing syndrome.

    Science.gov (United States)

    Zhang, Qian; Dou, Jingtao; Gu, Weijun; Yang, Guoqing; Lu, Juming

    2013-10-01

    The cortisol concentration in saliva is 10-fold lower than total serum cortisol and accurately reflects the serum concentration, both levels being lowest around midnight. The salivary cortisol assay measures free cortisol and is unaffected by confounding factors. This study analysed published data on the sensitivity and specificity of salivary cortisol levels in the diagnosis of Cushing syndrome. Data from studies on the use of different salivary cortisol assay techniques in the diagnosis of Cushing syndrome, published between 1998 and 2012 and retrieved using Ovid MEDLINE®, were analysed for variance and correlation. For the 11 studies analysed, mean sensitivity and specificity of the salivary cortisol assay were both >90%. Repeated measurements were easily made with this assay, enabling improved diagnostic accuracy in comparison with total serum cortisol measurements. This analysis confirms the reliability of the saliva cortisol assay as pragmatic tool for the accurate diagnosis of Cushing syndrome. With many countries reporting a rising prevalence of metabolic syndrome, diabetes and obesity--in which there is often a high circulating cortisol level--salivary cortisol measurement will help distinguish these states from Cushing syndrome.

  13. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  14. Assay of 25-OH vitamin D3

    International Nuclear Information System (INIS)

    Nayer, P. de; Thalasso, M.; Beckers, C.

    1977-01-01

    A simplified version of the competitive protein binding assay for 25-OH vit D3 derived from the method of Belsey et al. is presented. The procedure does not include a chromatography step, and is performed on an alcoolic extract of 0.1 ml plasma or serum. Normal rat serum (1:20,000) was used as binding protein. No β-lipoproteins were added to the assay buffer. A 10% displacement of the tracer was observed at 0.04 ng/tube, and 50% at 0.15 ng/tube, allowing for the measurement of 25-OH vit D3 concentrations between 2 ng/ml and 200 ng/ml. Mean values in a normal group was 23.1 +- 6.5 ng/ml (range 16-37 ng/ml, n = 11). (orig.) [de

  15. Cross-neutralization of antibodies induced by vaccination with Purified Chick Embryo Cell Vaccine (PCECV) against different Lyssavirus species.

    Science.gov (United States)

    Malerczyk, Claudius; Freuling, Conrad; Gniel, Dieter; Giesen, Alexandra; Selhorst, Thomas; Müller, Thomas

    2014-01-01

    Rabies is a neglected zoonotic disease caused by viruses belonging to the genus lyssavirus. In endemic countries of Asia and Africa, where the majority of the estimated 60,000 human rabies deaths occur, it is mainly caused by the classical rabies virus (RABV) transmitted by dogs. Over the last decade new species within the genus lyssavirus have been identified. Meanwhile 15 (proposed or classified) species exist, including Australian bat lyssavirus (ABLV), European bat lyssavirus (EBLV-1 and -2), Duvenhage virus (DUVV), as well as Lagos bat virus (LBV) and Mokola virus (MOKV) and recently identified novel species like Bokeloh bat lyssavirus (BBLV), Ikoma bat lyssavirus (IKOV) or Lleida bat lyssavirus (LLBV). The majority of these lyssavirus species are found in bat reservoirs and some have caused human infection and deaths. Previous work has demonstrated that Purified Chick Embryo Cell Rabies Vaccine (PCECV) not only induces immune responses against classical RABV, but also elicits cross-neutralizing antibodies against ABLV, EBLV-1 and EBLV-2. Using the same serum samples as in our previous study, this study extension investigated cross-neutralizing activities of serum antibodies measured by rapid fluorescent focus inhibition test (RFFIT) against selected other non-classical lyssavirus species of interest, namely DUVV and BBLV, as well as MOKV and LBV. Antibodies developed after vaccination with PCECV have neutralizing capability against BBLV and DUVV in the same range as against ABLV and EBLV-1 and -2. As expected, for the phylogenetically more distant species LBV no cross-neutralizing activity was found. Interestingly, 15 of 94 serum samples (16%) with a positive neutralizing antibody titer against RABV displayed specific cross-neutralizing activity (65-fold lower than against RABV) against one specific MOKV strain (Ethiopia isolate), which was not seen against a different strain (Nigeria isolate). Cross-neutralizing activities partly correlate with the

  16. Salivary and serum insulin-like growth factor (IGF-1) assays in anorexic patients.

    Science.gov (United States)

    Paszynska, Elzbieta; Dmitrzak-Weglarz, Monika; Slopien, Agnieszka; Tyszkiewicz-Nwafor, Marta; Rajewski, Andrzej

    2016-12-01

    The purpose of this study was to measure the salivary and serum free IGF-1 concentration of patients with anorexia nervosa (AN) in comparison to an average population. A controlled clinical trial was designed for an age- and gender-matched group of 121 AN patients and 77 healthy individuals. A clinical examination was made and blood and salivary samples were taken during the acute stage of AN (BMI measuring free IGF-1 was used. Anorexic patients had significant reductions in salivary unstimulated flow rate (UFR), pH and free IGF-1 levels in their saliva and serum. Significant correlations between serum IGF-1 and BMI; salivary IGF-1 and UFR and pH were detected. Salivary and serum IGF-1 analyses appear to be a reliable biochemical indicator of malnutrition in AN patients. Measurement of salivary IGF-1 levels would allow new perspectives in monitoring AN in its early stages.

  17. SiMa Cells for a Serotype Specific and Sensitive Cell-Based Neutralization Test for Botulinum Toxin A and E.

    Science.gov (United States)

    Bak, Nicola; Rajagopal, Shalini; Stickings, Paul; Sesardic, Dorothea

    2017-07-20

    Botulinum toxins (BoNTs), of which there are seven serotypes, are among the most potent neurotoxins, with serotypes A, B and E causing human botulism. Antitoxins form the first line of treatment for botulism, and functional, highly sensitive in vitro methods for toxin neutralization are needed to replace the current in vivo methods used for determination of antitoxin potency. In this preliminary proof of concept study, we report the development of a neutralization test using the neuroblastoma SiMa cell line. The assay is serotype specific for either BoNT/A or BoNT/E, which both cleave unique sequences on SNAP-25 within SiMa cells. The end point is simple immunodetection of cleaved SNAP-25 from cell lysates with antibodies detecting only the newly exposed sequence on SNAP-25. Neutralizing antibodies prevent the toxin-induced cleavage of SNAP-25. The toxin neutralization assay, with an EC50 of ~2 mIU/mL determined with a standardized reference antiserum, is more sensitive than the mouse bioassays. Relevance was demonstrated with commercial and experimental antitoxins targeting different functional domains, and of known in vivo neutralizing activities. This is the first report describing a simple, specific, in vitro cell-based assay for the detection of neutralizing antibodies against BoNT/A and BoNT/E with a sensitivity exceeding that of the mouse bioassay.

  18. Strong negative interference of ethamsylate (Dicynone®) in serum creatinine quantification via enzymatic assay using Trinder reaction.

    Science.gov (United States)

    Wiewiorka, Ondrej; Dastych, Milan; Čermáková, Zdenka

    2013-08-01

    With discrepancies encountered as early as the verification of enzymatic method for quantification of serum creatinine, our research pointed to a later confirmed interference caused by a compound called ethamsylate present in the commonly used antihemorrhagic drug Dicynone. We measured concentrations of creatinine of 10 patients with blood taken before and 15 minutes after the intravenous administration of a 500 mg dose of Dicynone. The creatinine concentration was determined using Jaffe method and enzymatic method that utilize Trinder reaction (Roche) in analyzer Cobas c 501 (Roche AG, Basel, Switzerland). We also monitored concentration of blood creatinine in three patients before and 15 minutes after application of Dicynone (500 mg i.v.) and in the following 6th, 12th, 18th, and 24th hours. We discovered a significant negative bias in creatinine results using enzymatic assay with Trinder reaction in blood taken 15 min after i.v. application of 500 mg Dicynone to patients compared to their pre-application values (average decrease of 47%). Unlike this, the results of compensated Jaffe method yielded steady results in all samples (average deviation 0.6% from original values). However, 12 h after the drug administration comparable results were seen as before the administration. Considering the strong negative interference of ethamsylate in enzymatic assay using Trinder reaction for creatinine quantification, blood from patients with prescribed Dicynone should be taken at least 12 h after the last application of the drug for obtaining the correct creatinine values.

  19. Radiosotopic assay and binder therefor

    International Nuclear Information System (INIS)

    Caston, J.D.; Kamen, B.A.

    1976-01-01

    A rapid and less costly radioisotopic assay for measuring the concentration of folate in blood serum is described. This procedure utilizes 3 H-pteroylmonoglutamate, unlabeled 5-methyltetrahydrofolic acid, and a partially purified folate binder, such as for example a folate binder extracted from hog kidney. The procedure involves radioisotopically relating the bound amounts of a labeled folate and a known folate at various concentrations of the known folate in a system containing a predetermined amount of the labeled folate, a predetermined amount of the binder factor for the folates, and a predetermined amount of defolated test serum. 16 claims, 8 drawing figures

  20. Determination of inorganic nitrate in serum and urine by a kinetic cadmium-reduction method.

    Science.gov (United States)

    Cortas, N K; Wakid, N W

    1990-08-01

    Nitrate in serum and urine was assayed by a modification of the cadmium-reduction method; the nitrite produced was determined by diazotization of sulfanilamide and coupling to naphthylethylene diamine. After samples were deproteinized with Somogyi reagent, the nitrate was reduced by Cu-coated Cd in glycine buffer at pH 9.7 (2.5 to 3 g of Cd granules for a 4-mL reaction mixture). The reduction followed pseudo-first-order reaction kinetics, a convenient time interval for assay being 75 to 90 min. Maximum reduction (85%) occurred at about 2 h. Detection limits in urine or serum were 2 to 250 mumol/L. This method does not require the reaction to go to completion, does not require expensive reagents or equipment, and can assay several samples simultaneously. Repeated assays of two serum pools gave CVs of 9.0% and 4.7% for nitrate concentrations of 31.4 and 80.2 mumol/L, respectively (n = 20 each). The mean concentration of nitrate was 1704.0 +/- 1294 (SD) mumol/L (n = 21) in untimed normal urine, 81.8 +/- 50.1 mumol/L in serum of 38 renal dialysis patients, and 51.2 +/- 26.4 mumol/L in serum of 38 controls.

  1. Assay of fluconazole by high-performance liquid chromatography with a mixed-phase column.

    OpenAIRE

    Wallace, J E; Harris, S C; Gallegos, J; Foulds, G; Chen, T J; Rinaldi, M G

    1992-01-01

    A mixed-phase liquid chromatographic column was used to assay fluconazole in plasma, serum, and cerebrospinal fluid. The assay was linear from 0.2 to 20 micrograms/ml, with an average coefficient of variation of less than 5%. The partitioning of the drug between serum and cerebrospinal fluid was determined for 34 patients. The method was demonstrated to be suitable for both pharmacokinetic studies and monitoring of patients receiving treatment with this antifungal agent.

  2. Heated oligonucleotide ligation assay (HOLA): an affordable single nucleotide polymorphism assay.

    Science.gov (United States)

    Black, W C; Gorrochotegui-Escalante, N; Duteau, N M

    2006-03-01

    Most single nucleotide polymorphism (SNP) detection requires expensive equipment and reagents. The oligonucleotide ligation assay (OLA) is an inexpensive SNP assay that detects ligation between a biotinylated "allele-specific detector" and a 3' fluorescein-labeled "reporter" oligonucleotide. No ligation occurs unless the 3' detector nucleotide is complementary to the SNP nucleotide. The original OLA used chemical denaturation and neutralization. Heated OLA (HOLA) instead uses a thermal stable ligase and cycles of denaturing and hybridization for ligation and SNP detection. The cost per genotype is approximately US$1.25 with two-allele SNPs or approximately US$1.75 with three-allele SNPs. We illustrate the development of HOLA for SNP detection in the Early Trypsin and Abundant Trypsin loci in the mosquito Aedes aegypti (L.) and at the a-glycerophosphate dehydrogenase locus in the mosquito Anopheles gambiae s.s.

  3. A rapid and quantitative assay for measuring antibody-mediated neutralization of West Nile virus infection

    International Nuclear Information System (INIS)

    Pierson, Theodore C.; Sanchez, Melissa D.; Puffer, Bridget A.; Ahmed, Asim A.; Geiss, Brian J.; Valentine, Laura E.; Altamura, Louis A.; Diamond, Michael S.; Doms, Robert W.

    2006-01-01

    West Nile virus (WNV) is a neurotropic flavivirus within the Japanese encephalitis antigenic complex that is responsible for causing West Nile encephalitis in humans. The surface of WNV virions is covered by a highly ordered icosahedral array of envelope proteins that is responsible for mediating attachment and fusion with target cells. These envelope proteins are also primary targets for the generation of neutralizing antibodies in vivo. In this study, we describe a novel approach for measuring antibody-mediated neutralization of WNV infection using virus-like particles that measure infection as a function of reporter gene expression. These reporter virus particles (RVPs) are produced by complementation of a sub-genomic replicon with WNV structural proteins provided in trans using conventional DNA expression vectors. The precision and accuracy of this approach stem from an ability to measure the outcome of the interaction between antibody and viral antigens under conditions that satisfy the assumptions of the law of mass action as applied to virus neutralization. In addition to its quantitative strengths, this approach allows the production of WNV RVPs bearing the prM-E proteins of different WNV strains and mutants, offering considerable flexibility for the study of the humoral immune response to WNV in vitro. WNV RVPs are capable of only a single round of infection, can be used under BSL-2 conditions, and offer a rapid and quantitative approach for detecting virus entry and its inhibition by neutralizing antibody

  4. Neutralized adenovirus-immune complexes can mediate effective gene transfer via an Fc receptor-dependent infection pathway.

    Science.gov (United States)

    Leopold, Philip L; Wendland, Rebecca L; Vincent, Theresa; Crystal, Ronald G

    2006-10-01

    Neutralization of adenovirus (Ad) by anti-Ad neutralizing antibodies in serum involves formation of Ad-immune complexes that prevent the virus from interacting with target cells. We hypothesized that Ad-immune complexes likely contain viable Ad vectors which, although no longer capable of gaining access to receptors on target cells, may be able to express transgenes in cells bearing Fc receptors for immunoglobulins, i.e., that antibody-based "neutralization" of Ad vectors may be circumvented by the Fc receptor pathway. To test this hypothesis, we expressed the Fcgamma receptor IIA (FcgammaR) in A549 lung epithelial cells or human dermal fibroblasts and evaluated gene transfer in the presence of human neutralizing anti-Ad serum. FcgammaR-expressing cells bound and internalized copious amounts of Ad, with a distinct population of internalized Ad trafficking to the nucleus. The dose-response curves for inhibition of gene transfer revealed that FcgammaR-expressing cells required a more-than-10-fold higher concentration of anti-Ad serum to achieve 50% inhibition of Ad-encoded beta-galactosidase expression compared with non-FcgammaR-expressing cells. The discrepancy between neutralization of Ad during infection of FcgammaR-expressing cells and neutralization of Ad during infection of non-FcgammaR-expressing cells occurred with either heat-inactivated or non-heat-inactivated sera, was blocked by addition of purified Fc domain protein, and did not require the cytoplasmic domain of FcgammaR, suggesting that immune complex internalization proceeded via endocytosis rather than phagocytosis. FcgammaR-mediated infection by Ad-immune complexes did not require expression of the coxsackie virus-Ad receptor (CAR) since similar data were obtained when CAR-deficient human dermal fibroblasts were engineered to express FcgammaR. However, interaction of the Ad penton base with cell surface integrins contributed to the difference in neutralization between FcgammaR-expressing and non

  5. ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors

    International Nuclear Information System (INIS)

    Wang Yiqing; Shi Zhixu

    2002-01-01

    Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors

  6. The clinical utility of serum ferritin levels in patients with malignant tumors treated by radiotherapy

    International Nuclear Information System (INIS)

    Mitsuhashi, Norio; Okazaki, Atsushi; Hayakawa, Kazushige; Nakano, Takashi; Yamanaka, Mikio

    1983-01-01

    The serum levels of ferritin in 394 patients, including 339 patients with various malignant tumors and 23 with various non-malignant diseases, and 32 healthy subjects were determined. The normal levels of ferritin were 82.7 +- 42.3 ng/ml for males and 42.0 +- 36.9 ng/ml for females. The positive ratio of serum ferritin level was 28% in patients with malignant tumors and 22% in patients with non-malignant diseases. The usefulness of serum ferritin assay in screening for malignant tumors appeared to be limited. High serum levels of ferritin were found in patients with malignant lymphoma (positive ratio: 42%), pulmonary cancer (38%) and esophageal cancer (37%). According to the histological types, epidermoid cancer appeared to produce a higher serum level of ferritin than adenocarcinoma in patients with pulmonary cancer. It was interesting that malignant lymphoma had a high serum level of ferritin in spite of its low serum level of CEA. Carcinoma of the digestive tracts except for esophagus was considered to have a normal serum ferritin level in spite of the advanced stage. There was no close relationship between serum ferritin levels and CEA levels in patients with pulmonary cancer and breast cancer. Serum CEA assay was more useful for detection of tumors than serum ferritin assay in patients with breast cancer. Serum ferritin levels in patients with good prognosis decreased following radiation therapy, but those in patients with poor prognosis elevated or unchanged in spite of therapy. Therefore, serial ferritin determinations may be useful for evaluation of radiotherapy and assessment of prognosis. (J.P.N.)

  7. Comparison of neutralizing and hemagglutination-inhibiting antibody responses to influenza A virus vaccination of human immunodeficiency virus-infected individuals

    NARCIS (Netherlands)

    Benne, CA; Harmsen, M; Tavares, L; Kraaijeveld, CA; De Jong, JC

    A neutralization enzyme immunoassay (N-EIA) was used to determine the neutralizing serum antibody titers to influenza A/Taiwan/1/86 (H1N1) and Beijing/353/89 (H3N2) viruses after vaccination of 51 human immunodeficiency virus (HIV) type 1-infected individuals and 10 healthy noninfected controls

  8. Investigations into the choice of immunogen, ligand, antiserum and assay conditions for the radioimmunoassay of conjugated cholic acid

    Energy Technology Data Exchange (ETDEWEB)

    Beckett, G J; Percy-Robb, I W [Royal Infirmary, Edinburgh (UK); Hunter, W M [Medical Research Council, Edinburgh (UK)

    1978-09-01

    Investigations into the choice of immunogen, ligand, antiserum and assay conditions for the radioimmunoassay of conjugated cholic acid have been performed with a view to producing optimal assay conditions. Cholic acid-BSA was found to be the best immunogen to produce antibodies to conjugated cholic acid and the response was of an IgG type. Incorporating a spacer (hexanoic acid) between hapten and carrier protein resulted in a decrease in antiserum titre. Optimal conditions for the assay were found using (/sup 125/I)histamine-glycocholic acid as ligand with a dilution of antiserum to produce 60% binding of ligand and a pH of 7.4. Using these assay conditions no serum effects were found; extraction of serum prior to assay was therefore unnecessary. The assay was sensitive enough to detect post-prandial increases in serum bile acid concentrations following a liquid test meal; no increase was observed throughout the same time period in a fasting control.

  9. Novel Autoantibody Serum and Cerebrospinal Fluid Biomarkers in Veterans with Gulf War Illness

    Science.gov (United States)

    2017-10-01

    using Western blot and ELISA assays. PURPOSE: Development of peripheral biomarkers for GWI. Scope of the Research: Serum and plasma from 250 Gulf War...basic protein (MBP), Myelin Associated Glycoprotein (MAG), CaMKII, alpha-synuclein, GFAP, S100B, Western Blot, ELISA , chronic fatigue syndrome (CFS...Milestone(s) Achieved: Site 1, 4 and 5 serum and CSF data collected and set up for laboratory assays ( ELISA , western blot). Autoantibody data shipped

  10. Development and validation of a Luminex assay for detection of a predictive biomarker for PROSTVAC-VF therapy

    Science.gov (United States)

    Lucas, Julie L.; Tacheny, Erin A.; Ferris, Allison; Galusha, Michelle; Srivastava, Apurva K.; Ganguly, Aniruddha; Williams, P. Mickey; Sachs, Michael C.; Thurin, Magdalena; Tricoli, James V.; Ricker, Winnie; Gildersleeve, Jeffrey C.

    2017-01-01

    Cancer therapies can provide substantially improved survival in some patients while other seemingly similar patients receive little or no benefit. Strategies to identify patients likely to respond well to a given therapy could significantly improve health care outcomes by maximizing clinical benefits while reducing toxicities and adverse effects. Using a glycan microarray assay, we recently reported that pretreatment serum levels of IgM specific to blood group A trisaccharide (BG-Atri) correlate positively with overall survival of cancer patients on PROSTVAC-VF therapy. The results suggested anti-BG-Atri IgM measured prior to treatment could serve as a biomarker for identifying patients likely to benefit from PROSTVAC-VF. For continued development and clinical application of serum IgM specific to BG-Atri as a predictive biomarker, a clinical assay was needed. In this study, we developed and validated a Luminex-based clinical assay for measuring serum IgM specific to BG-Atri. IgM levels were measured with the Luminex assay and compared to levels measured using the microarray for 126 healthy individuals and 77 prostate cancer patients. This assay provided reproducible and consistent results with low %CVs, and tolerance ranges were established for the assay. IgM levels measured using the Luminex assay were found to be highly correlated to the microarray results with R values of 0.93–0.95. This assay is a Laboratory Developed Test (LDT) and is suitable for evaluating thousands of serum samples in CLIA certified laboratories that have validated the assay. In addition, the study demonstrates that discoveries made using neoglycoprotein-based microarrays can be readily migrated to a clinical assay. PMID:28771597

  11. Overcoming the inhibitory effect of serum on lipofection by increasing the charge ratio of cationic liposome to DNA.

    Science.gov (United States)

    Yang, J P; Huang, L

    1997-09-01

    Since cationic liposome was first developed as a lipofection reagent, a drawback has been noted in that the efficiency of lipofection decreases dramatically after addition of serum to the lipofection medium. This drawback hampers the application of cationic liposome for systematic delivery of genes. In the present studies, we found that the effect of serum on DC-chol liposome-mediated lipofection is dependent on the charge ratio of liposome to DNA. Serum inhibited lipofection activity of the lipoplex at low charge ratios, whereas it enhanced the lipofection activity at high charge ratios. This phenomenon was observed using DOTAP/DOPE but not lipofectamine. Measurement of cellular association of DNA showed that serum could reduce the binding of lipoplex to cells at all tested charge ratios, i.e. 0-10.6. Removal of negatively charged proteins from serum by DEAE Sephacel column abolished the inhibitory effect of serum on lipofection. The fraction contained only negatively charged serum proteins which strongly inhibited lipofection at low charge ratios but not at higher charge ratios. Furthermore, preincubation of serum with positively charged polylysine, which neutralized negatively charged serum proteins, eliminated the inhibitory effect of serum on lipofection. In summary, inactivation of cationic liposome by serum is due to negatively charged serum proteins and it can be overcome by increasing charge ratio of cationic liposome-DNA lipoplexes or by neutralizing the serum with polylysine.

  12. Sperm DNA quality evaluated by comet assay and sperm chromatin structure assay in stallions after unilateral orchiectomy.

    Science.gov (United States)

    Serafini, R; Varner, D D; Bissett, W; Blanchard, T L; Teague, S R; Love, C C

    2015-09-15

    Unilateral orchiectomy (UO) may interfere with thermoregulation of the remaining testis caused by inflammation surrounding the incision site, thus altering normal spermatogenesis and consequently sperm quality. Two measures of sperm DNA quality (neutral comet assay and the sperm chromatin structure assay [SCSA]) were compared before UO (0 days) and at 14, 30, and 60 days after UO to determine whether sperm DNA changed after a mild testis stress (i.e., UO). The percent DNA in the comet tail was higher at 14 and 60 days compared to 0 days (P comet tail measures (i.e., length, moment, migration) were higher at all time periods after UO compared to 0 days (P comet assay and the SCSA, which was not identified using traditional measures of sperm quality. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  14. Prevalence of neutralizing antibodies to rabies virus in serum of seven species of insectivorous bats from Colorado and New Mexico, United States

    Science.gov (United States)

    Bowen, Richard A.; O'Shea, Thomas J.; Shankar, Vidya; Neubaum, Melissa A.; Neubaum, Daniel J.; Rupprecht, Charles E.

    2013-01-01

    We determined the presence of rabies-virus-neutralizing antibodies (RVNA) in serum of 721 insectivorous bats of seven species captured, sampled, and released in Colorado and New Mexico, United States in 2003-2005. A subsample of 160 bats was tested for rabies-virus RNA in saliva. We sampled little brown bats (Myotis lucifugus) at two maternity roosts in Larimer County, Colorado; big brown bats (Eptesicus fuscus) at three maternity roosts in Morgan County, Colorado; and big brown bats at five maternity roosts in Larimer County. We also sampled hoary bats (Lasiurus cinereus) and silver-haired bats (Lasionycteris noctivagans) captured while drinking or foraging over water in Bernalillo County, New Mexico and at various locations in Larimer County. Big brown bats, little brown bats, long-legged myotis (Myotis volans), long-eared myotis (Myotis evotis), and fringed myotis (Myotis thysanodes) were also sampled over water in Larimer County. All species except long-eared myotis included individuals with RVNA, with prevalences ranging from 7% in adult female silver-haired bats to 32% in adult female hoary bats. None of the bats had detectable rabies-virus RNA in oropharyngeal swabs, including 51 bats of 5 species that had RVNA in serum. Antibody-positive bats were present in nine of the 10 maternity colonies sampled. These data suggest that wild bats are commonly exposed to rabies virus and develop a humoral immune response suggesting some degree of viral replication, but many infections fail to progress to clinical disease.

  15. Influenza virus neutralizing antibodies and IgG isotype profiles after immunization of mice with influenza A subunit vaccine using various adjuvants

    NARCIS (Netherlands)

    Benne, CA; Harmsen, M; vanderGraaff, W; Verheul, AFM; Snippe, H; Kraaijeveld, CA

    The influence of various adjuvants on the development of influenza virus neutralizing antibodies and distribution of anti-influenza virus IgG isotypes after immunization of mice with influenza A (H3N2) subunit vaccine was investigated. Serum titres of influenza virus neutralizing antibodies and

  16. Discriminating the hemolytic risk of blood type A plasmas using the complement hemolysis using human erythrocytes (CHUHE) assay.

    Science.gov (United States)

    Cunnion, Kenji M; Hair, Pamela S; Krishna, Neel K; Sass, Megan A; Enos, Clinton W; Whitley, Pamela H; Maes, Lanne Y; Goldberg, Corinne L

    2017-03-01

    The agglutination-based cross-matching method is sensitive for antibody binding to red blood cells but is only partially predictive of complement-mediated hemolysis, which is important in many acute hemolytic transfusion reactions. Here, we describe complement hemolysis using human erythrocytes (CHUHE) assays that directly evaluate complement-mediated hemolysis between individual serum-plasma and red blood cell combinations. The CHUHE assay is used to evaluate correlations between agglutination titers and complement-mediated hemolysis as well as the hemolytic potential of plasma from type A blood donors. Plasma or serum from each type A blood donor was incubated with AB or B red blood cells in the CHUHE assay and measured for free hemoglobin release. CHUHE assays for serum or plasma demonstrate a wide, dynamic range and high sensitivity for complement-mediated hemolysis for individual serum/plasma and red blood cell combinations. CHUHE results suggest that agglutination assays alone are only moderately predictive of complement-mediated hemolysis. CHUHE results also suggest that plasma from particular type A blood donors produce minimal complement-mediated hemolysis, whereas plasma from other type A blood donors produce moderate to high-level complement-mediated hemolysis, depending on the red blood cell donor. The current results indicate that the CHUHE assay can be used to assess complement-mediated hemolysis for plasma or serum from a type A blood donor, providing additional risk discrimination over agglutination titers alone. © 2016 AABB.

  17. Radioimmunoassays of parathyroid hormone: Clinical value of the midregion and c-terminal assay

    International Nuclear Information System (INIS)

    Hengst, K.; Raidt, H.; Hoegemann, B.; Wagner, H.

    1984-01-01

    PTH was measured by midregion and carboxy-terminal assay in 20 patients suffering from primary hyperparathyroidism, 30 patients with secondary hyperparathyroidism, 10 persons with tertiary hyperparathyroidism, 50 patients who underwent transplantation of the kidney, 10 patients with hypoparathyroidism and 10 patients with other hypocalcemia as well as in 50 normal persons. Diagnosing hyperparathyroidism both assays were successful, when serum kreatinine was within the normal range. Especially midregion fragments became elevated, when serum kreatinine was above 2,0 mg. During renal failure diagnosis of hyperparathyroidism and hypoparathyroidism is more difficult. In normal renal function, however, the midregion assay is more sensitive for diagnosis of hypoparathyroidism compared to the carboxy-terminal assay. After kidney transplantation midregion levels of PTH are elevated, perhaps because of a failure of the transplanted kidney to eliminate the midregion fragment. (orig.) [de

  18. serum immunoglobulin levels in white, asiatic and bantu blood donors

    African Journals Online (AJOL)

    all assays were calculated as a percentage of the mean of. TABLE I. RESULTS OF IMMUNOGLOBULIN ASSAYS OF tOO WHITE, tOO ASIATIC AND 100 BANTU DONORS, EXPRESSED AS A. PERCENTAGE OF A CONTROL SERUM. Parameter. Range. Mean. Variance. Standard deviation. CoefI. of variation.

  19. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    Science.gov (United States)

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  20. Investigation of the solubility and the potentials for purification of serum amyloid A (SAA) from equine acute phase serum

    DEFF Research Database (Denmark)

    Christensen, Michelle Brønniche; Sørensen, Jens Christian; Jacobsen, Stine

    2013-01-01

    BACKGROUND: Serum amyloid A (SAA) is useful as a diagnostic marker of systemic inflammation in horses, but only heterologous assays based on non-equine calibration and standardization are available for measurements of equine SAA. More accurate measurements could be obtained using purified species......-specific SAA in native conformation for assay calibration and standardization. Further knowledge about the biochemical properties of SAA would facilitate a future production of native species-specific calibration material Therefore, the aim of the study was an investigation of the solubility and potentials...... for purification of equine SAA based on biochemical properties.Freeze dried equine acute phase serum was dissolved in 70% 2-propanol, 8 M urea, and milli-Q water, respectively. Supercritical fluid extraction (SFE), size-exclusive chromatography (FPLC-SEC), and preparative isoelectric focusing (IEF) were performed...

  1. The measurement of serum human parathyroid hormone (h-PTH53-84) and effect of exercise on calcium metabolism

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Taniguchi, Yoshiyuki; Aibata, Hirofumi; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    This study was focussed our attention on the measurement within the upper physiological level of human serum parathyroid hormone (PTH), using kits of human PTH 53 - 84. This assay kit was able to detect serum PTH in sera with suble changes of serum calcium concentrations before and after short term exercise. These serum PTH levels before and after exercise seemed to be changed within the upper physiological levels of PTH. Thus, this study suggested that the assay kit was likely to become a useful tool of the measurement of the physiological level of serum PTH in humans. (author)

  2. Evaluation of antivenoms in the neutralization of hyperalgesia and edema induced by Bothrops jararaca and Bothrops asper snake venoms

    Directory of Open Access Journals (Sweden)

    Picolo G.

    2002-01-01

    Full Text Available Neutralization of hyperalgesia induced by Bothrops jararaca and B. asper venoms was studied in rats using bothropic antivenom produced at Instituto Butantan (AVIB, 1 ml neutralizes 5 mg B. jararaca venom and polyvalent antivenom produced at Instituto Clodomiro Picado (AVCP, 1 ml neutralizes 2.5 mg B. aspar venom. The intraplantar injection of B. jararaca and B. asper venoms caused hyperalgesia, which peaked 1 and 2 h after injection, respectively. Both venoms also induced edema with a similar time course. When neutralization assays involving the independent injection of venom and antivenom were performed, the hyperalgesia induced by B. jararaca venom was neutralized only when bothropic antivenom was administered iv 15 min before venom injection, whereas edema was neutralized when antivenom was injected 15 min or immediately before venom injection. On the other hand, polyvalent antivenom did not interfere with hyperalgesia or edema induced by B. asper venom, even when administered prior to envenomation. The lack of neutralization of hyperalgesia and edema induced by B. asper venom is not attributable to the absence of neutralizing antibodies in the antivenom, since neutralization was achieved in assays involving preincubation of venom and antivenom. Cross-neutralization of AVCP or AVIB against B. jararaca and B. asper venoms, respectively, was also evaluated. Only bothropic antivenom partially neutralized hyperalgesia induced by B. asper venom in preincubation experiments. The present data suggest that hyperalgesia and edema induced by Bothrops venoms are poorly neutralized by commercial antivenoms even when antibodies are administered immediately after envenomation.

  3. Systematic review with meta-analysis: diagnostic performance of the combination of pepsinogen, gastrin-17 and anti-Helicobacter pylori antibodies serum assays for the diagnosis of atrophic gastritis.

    Science.gov (United States)

    Zagari, R M; Rabitti, S; Greenwood, D C; Eusebi, L H; Vestito, A; Bazzoli, F

    2017-10-01

    The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays (panel test) is a non-invasive tool for the diagnosis of atrophic gastritis. However, the diagnostic reliability of this test is still uncertain. To assess the diagnostic performance of the serum panel test for the diagnosis of atrophic gastritis. Medline via PubMed, Embase, Scopus, Cochrane Library databases and abstracts of international conferences proceedings were searched from January 1995 to December 2016 using the primary keywords "pepsinogens," "gastrin," "atrophic gastritis," "gastric precancerous lesions." Studies were included if they assessed the accuracy of the serum panel test for the diagnosis of atrophic gastritis using histology according to the updated Sydney System as reference standard. Twenty studies with a total of 4241 subjects assessed the performance of serum panel test for the diagnosis of atrophic gastritis regardless of the site in the stomach. The summary sensitivity was 74.7% (95% confidence interval (CI), 62.0-84.3) and the specificity was 95.6% (95%CI, 92.6-97.4). With a prevalence of atrophic gastritis of 27% (median prevalence across the studies), the negative predictive value was 91%. Few studies with small sample size assessed the performance of the test in detecting the site of atrophic gastritis. The combination of pepsinogen, gastrin-17 and anti-H. pylori antibodies serological assays appears to be a reliable tool for the diagnosis of atrophic gastritis. This test may be used for screening subjects or populations at high risk of gastric cancer for atrophic gastritis; however, a cost-effectiveness analysis is needed. © 2017 John Wiley & Sons Ltd.

  4. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  5. Development of a high-throughput colorimetric Zika virus infection assay.

    Science.gov (United States)

    Müller, Janis A; Harms, Mirja; Schubert, Axel; Mayer, Benjamin; Jansen, Stephanie; Herbeuval, Jean-Philippe; Michel, Detlef; Mertens, Thomas; Vapalahti, Olli; Schmidt-Chanasit, Jonas; Münch, Jan

    2017-04-01

    Zika virus (ZIKV) is an emerging pathogen that causes congenital infections which may result in birth defects, such as microcephaly. Currently, no approved treatment or vaccination is available. ZIKV can be readily detected in cell culture where virally infected cells are normally stained by specific antibodies. As ZIKV regularly causes a cytopathic effect, we were wondering whether this viral property can be used to quantitatively determine viral infectivity. We here describe the use of an 3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2H-tetrazolium bromide-(MTT)-based cell viability assay that allows to determine ZIKV-induced cell death. We show that this colorimetric assay quantifies ZIKV infection over a broad range of viral dilutions in both monkey and human cells. It allows to determine inhibitory activities of antivirals that block ZIKV or to define the neutralizing antibody titers of ZIKV antisera. This MTT-based ZIKV detection assay can be evaluated by naked eye or computational tools, has a broad linear range, does not require large equipment or costly reagents, and thus represents a promising alternative to antibody-based assays, in particular in resource-poor settings. We propose to use this simple, fast, and cheap method for quantification of ZIKV neutralizing antibodies and testing of antiviral compounds.

  6. Endoscopic gastritis, serum pepsinogen assay, and Helicobacter pylori infection.

    Science.gov (United States)

    Lee, Sun-Young

    2016-09-01

    Endoscopic findings of the background gastric mucosa are important in the Helicobacter pylori-seroprevalent population. It is strongly correlated not only with the risk of gastric cancer, but also with the excretion ability of gastric mucosa cells. In noninfected subjects, common endoscopic findings are regular arrangement of collecting venules, chronic superficial gastritis, and erosive gastritis. In cases of active H. pylori infection, nodularity on the antrum, hemorrhagic spots on the fundus, and thickened gastric folds are common endoscopic findings. The secreting ability of the gastric mucosa cells is usually intact in both noninfected and actively infected stomachs, and the intragastric condition becomes hyperacidic upon inflammation. Increased serum pepsinogen II concentration correlates well with active H. pylori infection, and also indicates an increased risk of diffuse-type gastric cancer. In chronic inactive H. pylori infection, metaplastic gastritis and atrophic gastritis extending from the antrum (closed-type chronic atrophic gastritis) toward the corpus (open-type chronic atrophic gastritis) are common endoscopic findings. The intragastric environment is hypoacidic and the risk of intestinal-type gastric cancer is increased in such conditions. Furthermore, there is a decrease in serum pepsinogen I concentration when the secreting ability of the gastric mucosa cells is damaged. Serologic and endoscopic changes that occur upon H. pylori infection are important findings for estimating the secreting ability of the gastric mucosa cells, and could be applied for the secondary prevention of gastric cancer.

  7. Egg yolk antibodies for detection and neutralization of Clostridium botulinum type A neurotoxin.

    Science.gov (United States)

    Trott, D L; Yang, M; Gonzalez, J; Larson, A E; Tepp, W H; Johnson, E A; Cook, M E

    2009-05-01

    The objective of this research project was to determine the usefulness of an egg antibody platform for producing materials for the detection and neutralization of botulinum type A neurotoxin. Yield estimates for detection and neutralizing antibodies produced using methods described were calculated. Antibody specific to botulinum toxoid A (aToxoid) and toxin A (aBoNT/A) was produced by immunizing hens with botulinum toxoid A (toxoid) followed by increasing amounts of botulinum neurotoxin A (BoNT/A) in Freund incomplete adjuvant. Egg yolks were extracted with polyethylene glycol (PEG) for antibody detection and neutralization experiments. A model aToxoid/toxoid immunoassay using only egg yolk antibody was developed and had a detection limit of 1 pg/ml of toxoid. In an indirect enzyme-linked immunosorbent assay of BoNT/A-specific antibody, the aBoNT/A contained more BoNT/A-specific antibody than did the aToxoid, and aBoNT/A was as effective as commercial rabbit antibody. The aToxoid provided no protection against BoNT/A in a standard mouse neutralization assay; however, 1 mg of PEG-extracted aBoNT/A neutralized 4,000 lethal doses of BoNT/A injected intraperitoneally. Based on these results, we calculated that in 1 month one hen could produce more than 100 liters of antibody detection reagents or enough antibody to neutralize approximately 11.6 million mouse lethal doses of botulinum toxin. Utilization of an egg antibody platform is potentially rapid (28 to 70 days) and scalable to kilogram quantities using current egg production facilities with as few as 1,000 hens.

  8. Serum Vitamin A and Zinc Levels of Some Preschool Children in ...

    African Journals Online (AJOL)

    Serum levels of vitamin A (VA) and zinc of sixty-one randomly selected preschool children aged 4 to 60 months from Sokoto in the Northwestern Nigeria were investigated. The serum VA was assayed spectrophotometrically by ultraviolet irradiation method while Zn level was determined using atomic absorption ...

  9. Barcoded microchips for biomolecular assays.

    Science.gov (United States)

    Zhang, Yi; Sun, Jiashu; Zou, Yu; Chen, Wenwen; Zhang, Wei; Xi, Jianzhong Jeff; Jiang, Xingyu

    2015-01-20

    Multiplexed assay of analytes is of great importance for clinical diagnostics and other analytical applications. Barcode-based bioassays with the ability to encode and decode may realize this goal in a straightforward and consistent manner. We present here a microfluidic barcoded chip containing several sets of microchannels with different widths, imitating the commonly used barcode. A single barcoded microchip can carry out tens of individual protein/nucleic acid assays (encode) and immediately yield all assay results by a portable barcode reader or a smartphone (decode). The applicability of a barcoded microchip is demonstrated by human immunodeficiency virus (HIV) immunoassays for simultaneous detection of three targets (anti-gp41 antibody, anti-gp120 antibody, and anti-gp36 antibody) from six human serum samples. We can also determine seven pathogen-specific oligonucleotides by a single chip containing both positive and negative controls.

  10. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  11. Radioimmunoassay for 3,3',5'-triiodo-L-thyronine in unextracted serum: method and clinical results

    International Nuclear Information System (INIS)

    Nicod, P.; Burger, A.; Staeheli, V.; Vallotton, M.B.

    1976-01-01

    Serum 3,3',5'-triiodothyronine (rT 3 ) was measured with a radioimmunoassay in unextracted serum. The assay was specific and reproducible. The coefficients of variation for three different sera known for high, normal, and low rT 3 concentrations between assays were 4, 6, and 9 percent and within assays 4, 9, and 7 percent, respectively. In euthyroid subjects 20 to 60 years old, rT 3 was 450 +- 200 pg/ml (mean +- SD, n = 83). Serum rT 3 was found to be increased in hyperthyroidism (range: 762 to 2581 pg/ml; n = 11) but also in acute and chronic illness (up to 2400 pg/ml; n = 24) and in anorexia nervosa (536 to 1058 pg/ml; n = 7). In the latter two situations there was mostly an inverse change in serum 3,5,3'-triiodothyronine (T 3 ) which was in the low normal range or decreased. These findings suggest a metabolic control of thryoxine deiodination. A low serum rT 3 was found in 9 of 12 hypothyroid patients and in the serum of one chronically ill patient. Long-term treatment (1 to 7 years) with lithium carbonate slightly reduced serum rT 3 , although the changes were inside the normal range. Kidney function was not found to be necessary for its production, as anephric patients had normal rT 3 values. In addition, hemodialysis increased serum rT 3 , which is probably due to the heparin therapy

  12. Are "Market Neutral" Hedge Funds Really Market Neutral?

    OpenAIRE

    Andrew J. Patton

    2009-01-01

    Using a variety of different definitions of "neutrality," this study presents significant evidence against the neutrality to market risk of hedge funds in a range of style categories. I generalize standard definitions of "market neutrality," and propose five different neutrality concepts. I suggest statistical tests for each neutrality concept, and apply these tests to a database of monthly returns on 1423 hedge funds from five style categories. For the "market neutral" style, approximately o...

  13. Spectroscopic studies on the interaction and sonodynamic damage of neutral red (NR) to bovine serum albumin (BSA)

    Energy Technology Data Exchange (ETDEWEB)

    Liu Bin; Guo Ying [Department of Pharmacy, Liaoning University, Shenyang 110036 (China); Wang, Jun, E-mail: wangjun890@126.co [Department of Chemistry, Liaoning University, Shenyang 110036 (China); Xu Rui [Department of Chemistry, Liaoning University, Shenyang 110036 (China); Wang Xin; Wang Dan; Zhang Liqun [Department of Pharmacy, Liaoning University, Shenyang 110036 (China); Xu Yongnan [Department of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016 (China)

    2010-06-15

    In this paper, the interaction of neutral red (NR) with bovine serum albumin (BSA) and the sonodynamic damage to BSA under ultrasonic irradiation was studied by means of ultraviolet-visible (UV-vis) and fluorescence spectra. The quenching constant (K{sub SV}=5.749x10{sup 4} L/mol), binding constant (K{sub A}=3.19x10{sup 4} L/mol) and binding site number (n=0.9462) were measured. The binding distance (r=2.47 nm) between NR and BSA was obtained according to Foester's non-radiative energy transfer theory. The damage process of BSA molecules was detected by the hyperchromic effect of UV-vis spectra and quenching of intrinsic fluorescence spectra. In addition, the influencing factors such as ultrasonic irradiation time and NR concentration on the damage to BSA molecules were also considered. The results showed that the damage degree is enhanced with the increase of ultrasonic irradiation time and NR concentration. The possible mechanism of sonodynamic damage to BSA molecules was mainly mediated by singlet oxygen ({sup 1}O{sub 2}). Otherwise, the binding and damaging sites to BSA molecules were also estimated by synchronous fluorescence. The results indicated that the NR is more vicinal to tryptophan (Trp) residue than to tyrosine (Tyr) residue and the damage site is also mainly at Trp residues. The research result will bring a certain significance to use sonosensitive drugs in the fields of tumor treatment.

  14. Serum amyloid A and haptoglobin concentrations in serum and peritoneal fluid of healthy horses and horses with acute abdominal pain

    DEFF Research Database (Denmark)

    Pihl, Tina Holberg; Andersen, Pia Haubro; Kjelgaard-Hansen, Mads

    2013-01-01

    BACKGROUND: Peritoneal fluid (PF) analysis is a valuable diagnostic tool in equine medicine. Markers such as serum amyloid A (SAA) and haptoglobin (Hp) could facilitate the diagnosis of inflammatory abdominal conditions. OBJECTIVES: The objectives were to (1) establish reference intervals (RI......) for SAA and Hp in serum and PF in healthy horses, (2) compare SAA and Hp concentrations between healthy horses and horses with colic, and (3) to assess the correlation between serum and PF concentrations. METHODS: Serum amyloid A and Hp concentrations were determined by automated assays in prospectively...... enrolled healthy reference horses and horses with colic. RIs were calculated, group concentrations were compared by Student's t-test, and Pearson's correlation for serum and PF concentrations were determined. RESULTS: In healthy horses (n = 62) the measurements for SAA were below the detection limit (0...

  15. Engineering Venom’s Toxin-Neutralizing Antibody Fragments and Its Therapeutic Potential

    Directory of Open Access Journals (Sweden)

    Larissa M. Alvarenga

    2014-08-01

    Full Text Available Serum therapy remains the only specific treatment against envenoming, but anti-venoms are still prepared by fragmentation of polyclonal antibodies isolated from hyper-immunized horse serum. Most of these anti-venoms are considered to be efficient, but their production is tedious, and their use may be associated with adverse effects. Recombinant antibodies and smaller functional units are now emerging as credible alternatives and constitute a source of still unexploited biomolecules capable of neutralizing venoms. This review will be a walk through the technologies that have recently been applied leading to novel antibody formats with better properties in terms of homogeneity, specific activity and possible safety.

  16. Hepatitis C virus resistance to broadly neutralizing antibodies measured using replication-competent virus and pseudoparticles.

    Science.gov (United States)

    Wasilewski, Lisa N; Ray, Stuart C; Bailey, Justin R

    2016-11-01

    A better understanding of natural variation in neutralization resistance and fitness of diverse hepatitis C virus (HCV) envelope (E1E2) variants will be critical to guide rational development of an HCV vaccine. This work has been hindered by inadequate genetic diversity in viral panels and by a lack of standardization of HCV entry assays. Neutralization assays generally use lentiviral pseudoparticles expressing HCV envelope proteins (HCVpp) or chimeric full-length viruses that are replication competent in cell culture (HCVcc). There have been few systematic comparisons of specific infectivities of E1E2-matched HCVcc and HCVpp, and to our knowledge, neutralization of E1E2-matched HCVpp and HCVcc has never been compared using a diverse panel of human broadly neutralizing monoclonal antibodies (bNAbs) targeting distinct epitopes. Here, we describe an efficient method for introduction of naturally occurring E1E2 genes into a full-length HCV genome, producing replication-competent chimeric HCVcc. We generated diverse panels of E1E2-matched HCVcc and HCVpp and measured the entry-mediating fitness of E1E2 variants using the two systems. We also compared neutralization of E1E2-matched HCVcc and HCVpp by a diverse panel of human bNAbs targeting epitopes across E1E2. We found no correlation between specific infectivities of E1E2-matched HCVcc versus HCVpp, but found a very strong positive correlation between relative neutralization resistance of these same E1E2-matched HCVcc and HCVpp variants. These results suggest that quantitative comparisons of neutralization resistance of E1E2 variants can be made with confidence using either HCVcc or HCVpp, allowing the use of either or both systems to maximize diversity of neutralization panels.

  17. Development and characterization of human monoclonal antibodies that neutralize multiple TGFβ isoforms.

    Science.gov (United States)

    Bedinger, Daniel; Lao, Llewelyn; Khan, Shireen; Lee, Steve; Takeuchi, Toshihiko; Mirza, Amer M

    2016-01-01

    Transforming growth factor (TGF)β levels are elevated in, and drive the progression of, numerous disease states such as advanced metastatic cancer and systemic and ocular fibrosis. There are 3 main isoforms, TGFβ1, 2, and 3. As multiple TGFβ isoforms are involved in disease processes, maximal therapeutic efficacy may require neutralization of 2 or more of the TGFβ isoforms. Fully human antibody phage display libraries were used to discover a number of antibodies that bind and neutralize various combinations of TGFβ1, 2 or 3. The primary panning did not yield any uniformly potent pan-isoform neutralizing antibodies; therefore, an antibody that displayed potent TGFβ 1, 2 inhibition, but more modest affinity versus TGFβ3, was affinity matured by shuffling with a light chain sub-library and further screening. This process yielded a high affinity pan-isoform neutralizing clone. Antibodies were analyzed and compared by binding affinity, as well as receptor and epitope competition by surface plasmon resonance methods. The antibodies were also shown to neutralize TGFβ effects in vitro in 3 assays: 1) interleukin (IL)-4 induced HT-2 cell proliferation; 2) TGFβ-mediated IL-11 release by A549 cells; and 3) decreasing SMAD2 phosphorylation in Detroit 562 cells. The antibodies' potency in these in vitro assays correlated well with their isoform-specific affinities. Furthermore, the ability of the affinity-matured clone to decrease tumor burden in a Detroit 562 xenograft study was superior to that of the parent clone. This affinity-matured antibody acts as a very potent inhibitor of all 3 main isoforms of TGFβ and may have utility for therapeutic intervention in human disease.

  18. Establishment of immunoradiometric assay for free prostate-specific antigen

    International Nuclear Information System (INIS)

    Ma Lianxue

    2009-01-01

    An immunoradiometric assay (IRMA) of free prostate specific antigen (F-PSA) in serum was established. One monoclonal antibody against total PSA (T-PSA) was coated on the plastic tubes, the other against F-PSA was labeled with 125 I. The sensitivity of assay was 0.04 μg/L (n=20, +2s), the CVs were 2.9%-4.0% for the intra-assay and 3.5%-10.5% for the inter-assay and the average recovery was 102.7%. The correlative equation comparing with the FPSA-RIA (CIS BIO) is y=0.965 1 χ -0.001 1, and r=0.996 4. This F-PSA IRMA is a sensitive and precise method in detecting F-PSA and fit for the vitro assay. (authors)

  19. Comparison of two assays for detection of antibodies against canine parvovirus and canine distemper virus in dogs admitted to a Florida animal shelter.

    Science.gov (United States)

    Gray, Lauren K; Crawford, P Cynda; Levy, Julie K; Dubovi, Edward J

    2012-05-01

    To compare 2 assays for use in the identification of dogs with a protective antibody titer (PAT) against canine parvovirus (CPV) and canine distemper virus (CDV). Prospective cross-sectional study. 431 dogs admitted to a municipal animal shelter in north central Florida. Blood samples were collected from dogs on the day of admission to the shelter. Serum was obtained, criterion-referenced assays were used to identify dogs that had PATs against CPV (titers ≥ 80; hemagglutination inhibition assay) and CDV (titers ≥ 32; virus neutralization assay), and results were compared with results of a semiquantitative ELISA and an immunofluorescence assay (IFA). For correct identification of dogs that had PATs against viruses, the ELISA had significantly higher specificity for CPV (98%) and CDV (95%) than did the IFA (82% and 70%, respectively) and had significantly lower sensitivity for CDV (88%) than did the IFA (97%); the sensitivity for CPV was similar (ELISA, 98%; IFA, 97%). Overall diagnostic accuracy was significantly greater with the ELISA than with the IFA. Predictive value of a positive result for PATs was significantly higher with the ELISA for CPV (99%) and CDV (93%) than with the IFA (92% and 71%, respectively). The ELISA had fewer false-positive results than did the IFA and could be performed on-site in shelters in < 1 hour. Accuracy and practicality of the ELISA may be useful for identifying the infection risk of dogs exposed during outbreaks attributable to CPV and CDV infections in shelters.

  20. Detecting tau in serum of transgenic animal models after tau immunotherapy treatment.

    Science.gov (United States)

    d'Abramo, Cristina; Acker, Christopher M; Schachter, Joel B; Terracina, Giuseppe; Wang, Xiaohai; Forest, Stefanie K; Davies, Peter

    2016-01-01

    In the attempt to elucidate if the "peripheral sink hypothesis" could be a potential mechanism of action for tau removal in passive immunotherapy experiments, we have examined tau levels in serum of chronically injected JNPL3 and Tg4510 transgenic animals. Measurement of tau in serum of mice treated with tau antibodies is challenging because of the antibody interference in sandwich enzyme-linked immunosorbent assays. To address this issue, we have developed a heat-treatment protocol at acidic pH to remove interfering molecules from serum, with excellent recovery of tau. The present data show that pan-tau and conformational antibodies do increase tau in mouse sera. However, these concentrations in serum do not consistently correlate with reductions of tau pathology in brain, suggesting that large elevations of tau species measured in serum are not predictive of efficacy. Here, we describe a reliable method to detect tau in serum of transgenic animals that have undergone tau immunotherapy. Levels of tau in human serum are less than the sensitivity of current assays, although artifactual signals are common. The method may be useful in similarly treated humans, a situation in which false positive signals are likely. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Radioimmunoassay for detection of VP1 specific neutralizing antibodies of foot and mouse disease virus

    International Nuclear Information System (INIS)

    Patzer, E.J.; Jackson, M.L.; Moore, D.M.

    1985-01-01

    A solid-phase radioimmunoassay was developed for the detection of antibodies against a specific region of the VP1 protein of the A24 and O1 serotypes of foot and mouth disease virus. The antibody titers from the radioimmunoassay showed a positive correlation with neutralizing antibody titers determined by a mouse protection assay. The specificity of the assay resides in the peptide used as antigen. The assay is rapid, reproducible and does not require the use of whole virions. (orig.)

  2. Serum endocan levels before and after surgery on low-grade gliomas.

    Science.gov (United States)

    Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda

    2017-01-01

    Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.

  3. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  4. Development of in vitro assay method with radioisotope

    International Nuclear Information System (INIS)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W.; Oh, O. D.

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([ 125 I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [ 125 I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides

  5. Development of in vitro assay method with radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W. [Korea Atomic Energy Research Institute. Korea Cancer Center Hospital, Seoul (Korea, Republic of); Oh, O. D. [Yonsei University, Seoul (Korea, Republic of)

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([{sup 125}I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [{sup 125}I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides.

  6. Serum ferritin, serum nitric oxide, and cognitive function in pediatric thalassemia major

    Directory of Open Access Journals (Sweden)

    Septiana Nur Qurbani

    2017-06-01

    Full Text Available Background Hemolysis and repeated blood transfusions in children with thalassemia major cause iron overload in various organs, including the brain, and may lead to neurodegeneration. Hemolysis also causes decreased levels of nitric oxide, which serves as a volume transmitter and slow dynamic modulation, leading to cognitive impairment. Objective To assess for correlations between serum ferritin as well as nitric oxide levels and cognitive function in children with thalassemia major.  Methods This analytical study with cross-sectional design on 40 hemosiderotic thalassemia major patients aged 6−14 years, was done at the Thalassemia Clinic in Dr. Hasan Sadikin Hospital, Bandung, West Java, from May to June 2015. Serum ferritin measurements were performed by an electrochemiluminescence immunoassay; serum nitric oxide was assayed by a colorimetric procedure based on Griess reaction; and cognitive function was assessed by the Wechsler Intelligence Scale for Children test. Statistical analysis was done using Spearman’s Rank correlation, with a significance value of 0.05. Results Abnormal values in verbal, performance, and full scale IQ were found in 35%, 57.5% and 57.5%, respectively. Serum nitric oxide level was significantly correlated with performance IQ (P=0.022, but not with verbal IQ (P=0.359 or full scale IQ (P=0.164. There were also no significant correlations between serum ferritin level and full scale, verbal, or performance IQ (P=0.377, 0.460, and 0.822, respectively. Conclusion Lower serum nitric oxide level is significantly correlated to lower cognitive function, specifically in the performance IQ category. However, serum ferritin level has no clear correlation with cognitive function.

  7. Novel, Anti-hTNF-α Variable New Antigen Receptor Formats with Enhanced Neutralizing Potency and Multifunctionality, Generated for Therapeutic Development

    Directory of Open Access Journals (Sweden)

    Obinna C. Ubah

    2017-12-01

    Full Text Available The management of chronic inflammatory diseases, such as inflammatory bowel disease, psoriasis, and rheumatoid arthritis has significantly improved over the last decade with the clinical availability of anti-TNF-α biologics. Despite this undoubted treatment success, a combination of acquired resistance together with an increased risk of systemic complications, means that a significant number of patients either fail to find a suitable targeted therapy or frustratingly discover that an approach that did work is no longer efficacious. Here, we report the isolation and characterization of a new class of super-neutralizing anti-TNF-α biologics formats, the building blocks of which were originally derived as variable new antigen receptor (VNAR domains from an immunized nurse shark. These parental small, stable VNAR monomers recognize and neutralize tumor necrosis factor (TNF-α, in cell-based assays, at nanomolar concentrations. However, the simple, single-chain molecular architecture of VNARs allows for easy and multiple reformatting options. Through reformatting, we achieved a 50,000-fold enhancement in in vitro efficacy with super-neutralizing fusion proteins able to block TNF-α induced cytotoxicity in the 2–5 pM range while retaining other functionality through the addition of fusion proteins known to extend serum half-life in vivo. In an in vitro intestinal epithelial barrier dysfunction efficacy model, the lead VNAR domains, restored barrier function and prevented paracellular flux with comparable efficacy to adalimumab (Humira®. In addition, all multivalent VNAR constructs restored trans-epithelial electrical resistance (TEER to approximately 94% of the untreated control. Reformatted VNAR domains should be considered as a new class of biologic agents for the treatment of hTNF-α driven diseases; either used systemically with appropriate half-life extension or alternatively where site-specific delivery of small and stable neutralizers

  8. Forms of vitamin B12 in radioisotope dilution assays

    International Nuclear Information System (INIS)

    Begley, J.A.; Hall, C.A.

    1981-01-01

    Since the presence of analogues of vitamin B 12 (B 12 , cobalamin, Cbl) has been postulated as the basis for the high values obtained by some radioisotope dilution assays (RIDA) of serum Cbl, serum was examined for analogues. None could be demonstrated in the extracts of serum prepared for RIDA as sought by both direct and indirect techniques. The natural forms of serum Cbl were converted to cyanocobalamin (CN Cbl) by this process of extraction which included cyanide (CN). The correctly performed RIDA for Cbl based on R binder gave higher values than a RIDA based on intrinsic factor or than by bioassay. By exclusion, the difference appeared to be due to unidentified factors rather than the presence of analogues. (author)

  9. Linearization of the bradford protein assay.

    Science.gov (United States)

    Ernst, Orna; Zor, Tsaffrir

    2010-04-12

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.

  10. Application of radioreceptor assay of benzodiazepines for toxicology

    International Nuclear Information System (INIS)

    Aaltonen, L.; Scheinin, M.

    1982-01-01

    A radioreceptor assay (RRA) for determining benzodiazepines (BZ) has been developed and applied to toxicological analysis of serum samples from 21 patients with acute BZ overdosage. The method was sensitive (e.g., lorazepam 17 nM, diazepam 41 nM), and specific for pharmacologically active BZ derivatives. The reproducibility of the results was good (intra-assay variation < 8%, inter-assay variation < 10%). Concentrations measured by the RRA showed a good correlation with those obtained by gas-liquid chromatographic analysis of the same samples. The quantitative results represent the sum of one or several parent substances and all biologically active metabolites, in proportion to their receptor binding affinities. (author)

  11. Clinical review: improving the measurement of serum thyroglobulin with mass spectrometry.

    Science.gov (United States)

    Hoofnagle, Andrew N; Roth, Mara Y

    2013-04-01

    Serum thyroglobulin (Tg) measurements are central to the management of patients treated for differentiated thyroid carcinoma. For decades, Tg measurements have relied on methods that are subject to interference by commonly found substances in human serum and plasma, such as Tg autoantibodies. As a result, many patients need additional imaging studies to rule out cancer persistence or recurrence that could be avoided with more sensitive and specific testing methods. The aims of this review are to: 1) briefly review the interferences common to Tg immunoassays; 2) introduce readers to liquid chromatography-tandem mass spectrometry as a method for quantifying proteins in human serum/plasma; and 3) discuss the potential benefits and limitations of the method in the quantification of serum Tg. Mass spectrometric methods have traditionally lacked the sensitivity, robustness, and throughput to be useful clinical assays. These methods failed to meet the necessary clinical benchmarks due to the nature of the mass spectrometry workflow and instrumentation. Over the past few years, there have been major advances in reagents, automation, and instrumentation for the quantification of proteins using mass spectrometry. More recently, methods using mass spectrometry to detect and quantify Tg have been developed and are of sufficient quality to be used in the management of patients. Novel serum Tg assays that use mass spectrometry may avoid the issue of autoantibody interference and other problems with currently available immunoassays for Tg. Prospective studies are needed to fully understand the potential benefits of novel Tg assays to patients and care providers.

  12. The stability of complement-mediated bactericidal activity in human serum against Salmonella.

    Directory of Open Access Journals (Sweden)

    Colette M O'Shaughnessy

    Full Text Available The complement cascade includes heat-labile proteins and care is required when handling serum in order to preserve its functional integrity. We have previously used a whole human serum bactericidal assay to show that antibody and an intact complement system are required in blood for killing of invasive isolates of Salmonella. The aim of the present study was to evaluate the conditions under which human serum can be stored and manipulated while maintaining complement integrity. Serum bactericidal activity against Salmonella was maintained for a minimum of 35 days when stored at 4°C, eight days at 22°C and 54 hours at 37°C. Up to three freeze-thaw cycles had no effect on the persistence of bactericidal activity and hemolytic complement assays confirmed no effect on complement function. Delay in the separation of serum for up to four days from clotted blood stored at 22°C did not affect bactericidal activity. Dilution of serum resulted in an increased rate of loss of bactericidal activity and so serum should be stored undiluted. These findings indicate that the current guidelines concerning manipulation and storage of human serum to preserve complement integrity and function leave a large margin for safety with regards to bactericidal activity against Salmonella. The study provides a scheme for determining the requirements for serum handling in relation to functional activity of complement in other systems.

  13. Enzyme-immuno assay for total estrogens and human placental lactogen. Comparison with radio-immuno-assay in normal pregnancy-monitoring

    International Nuclear Information System (INIS)

    Raichvarg, D.; Tallet, F.; Lajeunie, E.; Bonnaire, Y.; Danglas, P.

    1980-01-01

    The concentrations of estrogens (E) and human placental lactogen (HLP) are estimated in sera by radio immuno-assay (RIA) and enzyme-immuno-assay (EIA). Statistical data indicate mean intra-assay variation coefficients of 7% and 12% for E and HLP tests, respectively. The correlation coefficient (RIA/EIA) are found higher than 0,9% for both hormonal assays. The dilution curves obtained by RIA and EIA are similar. However, Student'test gives a significant difference for E determination. In fact, total E and E 3 only are measured by EIA and RIA, respectively. In most cases biological interferences are negligible except for HLP in presence of higher protein or haemoglobin levels. RIA and EIA are performed to study serum HLP and E levels throughout normal pregnancies. Results allow to use EIA for HLP and E evaluations in pregnancy-monitoring [fr

  14. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  15. Comparative Analysis of Serum (Antioxidative Status Parаmeters in Healthy Persons

    Directory of Open Access Journals (Sweden)

    Tatjana Ruskovska

    2013-03-01

    Full Text Available Five antioxidant and two oxidative stress assays were applied to serum samples of 43 healthy males. The antioxidant tests showed different inter-assay correlations. A very good correlation of 0.807 was observed between the ferric reducing ability of plasma (FRAP and total antioxidant status (TAS assay and also a fair correlation of 0.501 between the biological antioxidant potential (BAP and TAS assay. There was no statistically significant correlation between the BAP and FRAP assay. The anti-oxidant assays have a high correlation with uric acid, especially the TAS (0.922 and FRAP assay (0.869. The BAP assay has a much lower and no statistically significant correlation with uric acid (0.302, which makes BAP more suitable for the antioxidant status. The total thiol assay showed no statistically significant correlation with uric acid (0.114. The total thiol assay, which is based on a completely different principle, showed a good and statistically significant correlation with the BAP assay (0.510 and also to the TAS assay, but to a lower and not significant extent (0.279 and not with the FRAP assay (−0.008. The oxy-adsorbent test (OXY assay has no correlation with any of the other assays tested. The oxidative stress assays, reactive oxygen metabolites (ROM and total oxidant status (TOS, based on a different principle, do not show a statistically significant correlation with the serum samples in this study. Both assays showed a negative, but not significant, correlation with the antioxidant assays. In conclusion, the ROM, TOS, BAP and TTP assays are based on different principles and will have an additional value when a combination of these assays will be applied in large-scale population studies.

  16. Detection of Serum IgG4 Levels in Patients with IgG4-Related Disease and Other Disorders

    Science.gov (United States)

    Wang, Chenqiong; Wu, Xuefen; Miao, Ye; Xiong, Hui; Bai, Lin; Dong, Lingli

    2015-01-01

    Objective Elevated serum IgG4 levels are an important hallmark for diagnosing IgG4-related disease (IgG4-RD), but can also be observed in other diseases. This study aimed to compare two different testing methods for IgG4: ELISA and nephelometric assay. Both assays were used to measure serum IgG4 concentrations, and to assess the prevalence of high serum IgG4 levels in both IgG4-RD and non-IgG4-RD diseases. Methods A total of 80 serum samples were tested using the nephelometric assay and ELISA method that we established. Serum IgG4 concentrations were determined by ELISA for 957 patients with distinct diseases, including 12 cases of IgG4-RD and 945 cases of non-IgG4-RD. Results IgG4 levels from 80 selected serum samples examined by ELISA were in agreement with those detected using the nephelometry assay. Meanwhile, the serum IgG4 concentrations measured by ELISA were also consistent with the clinical diagnoses of patients with IgG4-RD during the course of disease. The Elevated levels of serum IgG4 (>1.35 g/L) were detected in all IgG4-RD (12/12) patients, and the prevalence of high IgG4 serum levels was 3.39% in non-IgG4-RD cases. Among them, the positive rates of serum IgG4 were 2.06% in patients with carcinoma and 6.3% in patients with other non-IgG4 autoimmune diseases. Conclusion Our established ELISA method is a reliable and convenient technique, which could be extensively used in the clinic to measure serum IgG4 levels. High levels of IgG4 were observed in IgG4-RD. However, this phenomenon could also be observed in other diseases, such as carcinomas and other autoimmune diseases. Thus, a diagnosis of IgG4 disease cannot only be dependent on the detection of elevated serum IgG4 levels. PMID:25885536

  17. Validity of transcobalamin II-based radioassay for the determination of serum vitamin B12 concentrations

    International Nuclear Information System (INIS)

    Paltridge, G.; Rudzki, Z.; Ryall, R.G.

    1980-01-01

    A valid radioassay for the estimation of serum vitamin B 12 in the presence of naturally occurring vitamin B 12 (= cobalamin) analogues can be operated if serum transcobalamin II (TC II) is used as the binding protein. Serum samples that gave diagnostically discrepant results when their vitamin B 12 content was analysed (i) by a commercial radioassay known to be susceptible to interference from cobalamin analogues, and (ii) by microbiological assay, were further analysed by an alternative radioassay which uses the transcobalamins (principally TC II) of diluted normal serum as the assay binding protein. Concordance between the results from microbiological assay and the TC II-based radioassay was found in all cases. In an extended study over a three-year period, all routine serum samples sent for vitamin B 12 analysis that had a vitamin B 12 content of less than 320 ng/l by the TC II-based radioassay (reference range 200-850 ng/l) were reanalysed using an established microbiological method. Over 1000 samples were thus analysed. The data are presented to demonstrate the validity of the TC II-based radioassay results in this group of patients, serum samples from which are most likely to produce diagnostically erroneous vitamin B 12 results when analysed by a radioassay that is less specific for cobalamins. (author)

  18. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  19. Serum bactericidal activity as indicator of innate immunity in pacu Piaractus mesopotamicus (Holmberg, 1887

    Directory of Open Access Journals (Sweden)

    J.D. Biller-Takahashi

    2013-12-01

    Full Text Available The immune system of teleost fish has mechanisms responsible for the defense against bacteria through protective proteins in several tissues. The protein action can be evaluated by serum bactericidal activity and this is an important tool to analyze the immune system. Pacu, Piaractus mesopotamicus, is one of the most important fish in national aquaculture. However there is a lack of studies on its immune responses. In order to standardize and assess the accuracy of the serum bactericidal activity assay, fish were briefly challenged with Aeromonas hydrophila and sampled one week after the challenge. The bacterial infection increased the concentration of protective proteins, resulting in a decrease of colony-forming unit values expressed as well as an enhanced serum bactericidal activity. The protocol showed a reliable assay, appropriate to determine the serum bactericidal activity of pacu in the present experimental conditions.

  20. Motavizumab, A Neutralizing Anti-Respiratory Syncytial Virus (Rsv Monoclonal Antibody Significantly Modifies The Local And Systemic Cytokine Responses Induced By Rsv In The Mouse Model

    Directory of Open Access Journals (Sweden)

    Jafri Hasan S

    2007-10-01

    Full Text Available Abstract Motavizumab (MEDI-524 is a monoclonal antibody with enhanced neutralizing activity against RSV. In mice, motavizumab suppressed RSV replication which resulted in significant reduction of clinical parameters of disease severity. We evaluated the effect of motavizumab on the local and systemic immune response induced by RSV in the mouse model. Balb/c mice were intranasally inoculated with 106.5 PFU RSV A2 or medium. Motavizumab was given once intraperitoneally (1.25 mg/mouse as prophylaxis, 24 h before virus inoculation. Bronchoalveolar lavage (BAL and serum samples were obtained at days 1, 5 (acute and 28 (long-term post inoculation and analyzed with a multiplex assay (Beadlyte Upstate, NY for simultaneous quantitation of 18 cytokines: IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, KC (similar to human IL-8, IL-10, IL-12p40, IL-12p70, IL-13, IL-17, TNF-α, MCP-1, RANTES, IFN-γ and GM-CSF. Overall, cytokine concentrations were lower in serum than in BAL samples. By day 28, only KC was detected in BAL specimens at low concentrations in all groups. Administration of motavizumab significantly reduced (p

  1. Individual contributions of the human metapneumovirus F, G, and SH surface glycoproteins to the induction of neutralizing antibodies and protective immunity

    International Nuclear Information System (INIS)

    Skiadopoulos, Mario H.; Biacchesi, Stephane; Buchholz, Ursula J.; Amaro-Carambot, Emerito; Surman, Sonja R.; Collins, Peter L.; Murphy, Brian R.

    2006-01-01

    We evaluated the individual contributions of the three surface glycoproteins of human metapneumovirus (HMPV), namely the fusion F, attachment G, and small hydrophobic SH proteins, to the induction of serum HMPV-binding antibodies, serum HMPV-neutralizing antibodies, and protective immunity. Using reverse genetics, each HMPV protein was expressed individually from an added gene in recombinant human parainfluenza virus type 1 (rHPIV1) and used to infect hamsters once or twice by the intranasal route. The F protein was highly immunogenic and protective, whereas G and SH were only weakly or negligibly immunogenic and protective, respectively. Thus, in contrast to other paramyxoviruses, the HMPV attachment G protein is not a major neutralization or protective antigen. Also, although the SH protein of HMPV is a virion protein that is much larger than its counterparts in previously studied paramyxoviruses, it does not appear to be a significant neutralization or protective antigen

  2. Antibody class capture assay (ACCA) for rubella-specific IgM antibody.

    Science.gov (United States)

    Isaac, M; Payne, R A

    1982-01-01

    Enzyme-linked immunosorbent assays for IgM antirubella were carried out on 1,546 sera, using an IgM capture method with a F (ab')2 conjugate (ACCA). Under the conditions described, sera containing IgM antirubella bound up to 15 times as much enzyme activity as negative specimens. Paired serum specimens from 27 patients, serial serum specimens from 6 patients, and single serum specimens from 15 patients who had had recent rubella were examined by the haemagglutination inhibition test (HAI) in the presence and absence of 2-mercaptoethanol following sucrose density gradient centrifugation (SDGC). ACCA confirmed all the results found with HAI following SDGC. Specimens were examined from ten patients with congenital rubella; ACCA confirmed the results found with both immunofluorescence following SDGC and radioimmunoassay. Pre- and post-vaccination specimens from 123 patients who had been vaccinated against rubella were examined. An IgM response could only be demonstrated in the 57 cases when IgG was absent in the first specimen. The specificity of the assay was confirmed by testing 31 serum specimens from rubella immune patients that also contained rheumatoid factor, 163 serum specimens from patients with acute infections other than rubella, and 12 serum specimens from infants with miscellaneous neonatal abnormalities other than congenital rubella. The ACCA proved a simple, sensitive, and specific test for IgM antirubella and the results compared favourably with those obtained by the SDGC technique.

  3. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    International Nuclear Information System (INIS)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.; Stuzman, R.E.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadal function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men

  4. Total serum homocysteine as an indicator of vitamin B12 and folate status

    International Nuclear Information System (INIS)

    Chu, R.C.; Hall, C.A.

    1988-01-01

    Presented is a modification of an assay for total serum homocysteine (Hcy) in which the Hcy plus radioactive adenosine is converted enzymatically to labeled S-adenosylhomocysteine (AdoHcy). The modifications included a commerical source for the AdoHcy hydrolase, adenosine labeled with either 14 C or 3 H, and separation of the AdoHcy by thin layer chromatography. The assay was sensitive to 25 pmol. Hcy levels in sera from 18 controls ranged from 6.9 to 12.1 mumol/L with a mean of 9.1 and a SD of 1.5 mumol/L. The total serum Hcy was increased in vitamin B12 and folate deficiency. The level was high in congenital defects of vitamin B12 metabolism, blocking the methylation of Hcy regardless of the serum vitamin B12 levels, but was normal in the absence of tissue deficiency even if the serum vitamin B12 levels were low. The procedure has been found practical in two years of use and requires only 0.1 mL of serum

  5. A new semiquantitative radiometric opsonin assay

    International Nuclear Information System (INIS)

    Yamamura, M.; Valdimarsson, H.

    1978-01-01

    A new semiquantitative radiometric opsonin assay is described. It was found that the opsonin activity generated by incubating brewer's yeast, Saccharomyces cerevisiae, in medium containing less than 5% human serum was exclusively complement dependent. In contrast, C.albicans was effectively opsonized in the absence of complement. Antibodies and the early classical complement pathway did not contribute to the opsonization of S.cerevisiae and neither did C5-9. The brewer's yeast assay can therefore be used for measuring selectively the opsonizing capacity of the alternative pathway. Sera from approximately 7% of apparently healthy adult controls consistently failed to generate significant opsonin activity while 8 out of 26 patients with suspected immune deficiency of unknown cause were defective in this assay. All opsonin deficient sera so far tested had haemolytically normal alternative pathway and Factor B activity. (author)

  6. Serum protein inhibition of thyrotropin binding to human thyroid tissue

    International Nuclear Information System (INIS)

    Beall, G.N.; Chopra, I.J.; Solomon, D.H.; Kruger, S.R.

    1978-01-01

    We used a modificaton of the TSH radioreceptor assay to detect TSH-binding inhibition (TBI) activity in serum and serum fractions from normal subjects and patients with Graves' disease. TBI activity is present in normal IgG prepared by DEAE-Sephadex chromatography and in normal globulins prepared by precipitation at 1.6 M ammonium sulfate. Other normal serum proteins also had TBI activity when large concentrations were tested. Gel filtration chromatography and powder block electrophoresis were used to prepare fractions of normal and Graves' disease sera. In these fractions from normal serum, TBI activity was found in both γ-globulin and α-globulin-albumin fractions electrophoretically and in both 7S and 4S peaks from gel filtration. TBI activity from Graves' disease patients' sera was similarly distributed, but relatively more TBI accompanied the electrophoretic γ-globulins. Sepharose Protein-A and anti-IgG were used as immunoabsorbents to isolate and purify IgG from normal and Graves' disease sera. TBI activity in IgG was proportional to the IgG concentration, indicating that the TBI which migrates as a γ-globulin electrophoretically is an IgG and thus may possibly be an antibody. Inhibitory activity found in normal serum globulins and in the non-IgG fractions of both normal and abnormal sera seriously interferes with attempts to use the TSH radioreceptor assay to study the hypothesized anti-TSH receptor antibody in the serum of patients with Graves' disease

  7. Refractometric total protein concentrations in icteric serum from dogs.

    Science.gov (United States)

    Gupta, Aradhana; Stockham, Steven L

    2014-01-01

    To determine whether high serum bilirubin concentrations interfere with the measurement of serum total protein concentration by refractometry and to assess potential biases among refractometer measurements. Evaluation study. Sera from 2 healthy Greyhounds. Bilirubin was dissolved in 0.1M NaOH, and the resulting solution was mixed with sera from 2 dogs from which food had been withheld to achieve various bilirubin concentrations up to 40 mg/dL. Refractometric total protein concentrations were estimated with 3 clinical refractometers. A biochemical analyzer was used to measure biuret assay-based total protein and bilirubin concentrations with spectrophotometric assays. No interference with refractometric measurement of total protein concentrations was detected with bilirubin concentrations up to 41.5 mg/dL. Biases in refractometric total protein concentrations were detected and were related to the conversion of refractive index values to total protein concentrations. Hyperbilirubinemia did not interfere with the refractometric estimation of serum total protein concentration. The agreement among total protein concentrations estimated by 3 refractometers was dependent on the method of conversion of refractive index to total protein concentration and was independent of hyperbilirubinemia.

  8. Broadly-Reactive Neutralizing and Non-neutralizing Antibodies Directed against the H7 Influenza Virus Hemagglutinin Reveal Divergent Mechanisms of Protection.

    Directory of Open Access Journals (Sweden)

    Gene S Tan

    2016-04-01

    Full Text Available In the early spring of 2013, Chinese health authorities reported several cases of H7N9 influenza virus infections in humans. Since then the virus has established itself at the human-animal interface in Eastern China and continues to cause several hundred infections annually. In order to characterize the antibody response to the H7N9 virus we generated several mouse monoclonal antibodies against the hemagglutinin of the A/Shanghai/1/13 (H7N9 virus. Of particular note are two monoclonal antibodies, 1B2 and 1H5, that show broad reactivity to divergent H7 hemagglutinins. Monoclonal antibody 1B2 binds to viruses of the Eurasian and North American H7 lineages and monoclonal antibody 1H5 reacts broadly to virus isolates of the Eurasian lineage. Interestingly, 1B2 shows broad hemagglutination inhibiting and neutralizing activity, while 1H5 fails to inhibit hemagglutination and demonstrates no neutralizing activity in vitro. However, both monoclonal antibodies were highly protective in an in vivo passive transfer challenge model in mice, even at low doses. Experiments using mutant antibodies that lack the ability for Fc/Fc-receptor and Fc/complement interactions suggest that the protection provided by mAb 1H5 is, at least in part, mediated by the Fc-fragment of the mAb. These findings highlight that a protective response to a pathogen may not only be due to neutralizing antibodies, but can also be the result of highly efficacious non-neutralizing antibodies not readily detected by classical in vitro neutralization or hemagglutination inhibition assays. This is of interest because H7 influenza virus vaccines induce only low hemagglutination inhibiting antibody titers while eliciting robust antibody titers as measured by ELISA. Our data suggest that these binding but non-neutralizing antibodies contribute to protection in vivo.

  9. A Diverse Panel of Hepatitis C Virus Glycoproteins for Use in Vaccine Research Reveals Extremes of Monoclonal Antibody Neutralization Resistance.

    Science.gov (United States)

    Urbanowicz, Richard A; McClure, C Patrick; Brown, Richard J P; Tsoleridis, Theocharis; Persson, Mats A A; Krey, Thomas; Irving, William L; Ball, Jonathan K; Tarr, Alexander W

    2015-12-23

    Despite significant advances in the treatment of hepatitis C virus (HCV) infection, the need to develop preventative vaccines remains. Identification of the best vaccine candidates and evaluation of their performance in preclinical and clinical development will require appropriate neutralization assays utilizing diverse HCV isolates. We aimed to generate and characterize a panel of HCV E1E2 glycoproteins suitable for subsequent use in vaccine and therapeutic antibody testing. Full-length E1E2 clones were PCR amplified from patient-derived serum samples, cloned into an expression vector, and used to generate viral pseudoparticles (HCVpp). In addition, some of these clones were used to generate cell culture infectious (HCVcc) clones. The infectivity and neutralization sensitivity of these viruses were then determined. Bioinformatic and HCVpp infectivity screening of approximately 900 E1E2 clones resulted in the assembly of a panel of 78 functional E1E2 proteins representing distinct HCV genotypes and different stages of infection. These HCV glycoproteins differed markedly in their sensitivity to neutralizing antibodies. We used this panel to predict antibody efficacy against circulating HCV strains, highlighting the likely reason why some monoclonal antibodies failed in previous clinical trials. This study provides the first objective categorization of cross-genotype patient-derived HCV E1E2 clones according to their sensitivity to antibody neutralization. It has shown that HCV isolates have clearly distinguishable neutralization-sensitive, -resistant, or -intermediate phenotypes, which are independent of genotype. The panel provides a systematic means for characterization of the neutralizing response elicited by candidate vaccines and for defining the therapeutic potential of monoclonal antibodies. Hepatitis C virus (HCV) has a global burden of more than 170 million people, many of whom cannot attain the new, expensive, direct-acting antiviral therapies. A safe and

  10. Interstitial fluid contains higher in vitro IGF bioactivity than serum

    DEFF Research Database (Denmark)

    Espelund, Ulrick; Søndergaard, Klaus; Bjerring, Peter

    2012-01-01

    MEASURE: Serum and SBF concentrations of bioactive IGF (determined in vitro by specific IGF-I receptor (IGF-IR) phosphorylation assay), immunoreactive IGF and IGF binding protein (IGFBP) levels, Western ligand blotting (WLB) of IGFBPs and IGFBP-3 Western immunoblotting (WiB). RESULTS: The ability of SBF...... to phosphorylate the IGF-IR in vitro was 41±27% higher than that of serum (P=0.007 by repeated measures ANOVA). By contrast, immunoreactive IGF and IGFBP-concentrations were approximately 50% lower in SBF than in serum (all P≤0.002). A marked difference in the composition of IGFBPs between serum and SBF...... was observed, including 3-fold elevated amounts of IGFBP-3 fragments in SBF (Pvitro IGF bioactivity was higher in SBF than in serum. This may...

  11. Analysis of memory B cell responses and isolation of novel monoclonal antibodies with neutralizing breadth from HIV-1-infected individuals.

    Directory of Open Access Journals (Sweden)

    Davide Corti

    2010-01-01

    Full Text Available The isolation of human monoclonal antibodies (mAbs that neutralize a broad spectrum of primary HIV-1 isolates and the characterization of the human neutralizing antibody B cell response to HIV-1 infection are important goals that are central to the design of an effective antibody-based vaccine.We immortalized IgG(+ memory B cells from individuals infected with diverse clades of HIV-1 and selected on the basis of plasma neutralization profiles that were cross-clade and relatively potent. Culture supernatants were screened using various recombinant forms of the envelope glycoproteins (Env in multiple parallel assays. We isolated 58 mAbs that were mapped to different Env surfaces, most of which showed neutralizing activity. One mAb in particular (HJ16 specific for a novel epitope proximal to the CD4 binding site on gp120 selectively neutralized a multi-clade panel of Tier-2 HIV-1 pseudoviruses, and demonstrated reactivity that was comparable in breadth, but distinct in neutralization specificity, to that of the other CD4 binding site-specific neutralizing mAb b12. A second mAb (HGN194 bound a conserved epitope in the V3 crown and neutralized all Tier-1 and a proportion of Tier-2 pseudoviruses tested, irrespective of clade. A third mAb (HK20 with broad neutralizing activity, particularly as a Fab fragment, recognized a highly conserved epitope in the HR-1 region of gp41, but showed striking assay-dependent selectivity in its activity.This study reveals that by using appropriate screening methods, a large proportion of memory B cells can be isolated that produce mAbs with HIV-1 neutralizing activity. Three of these mAbs show unusual breadth of neutralization and therefore add to the current panel of HIV-1 neutralizing antibodies with potential for passive protection and template-based vaccine design.

  12. Serum Transforming Growth Factor Beta-1 as an Index of Chemical Hepato carcinogenesis in Rats

    International Nuclear Information System (INIS)

    Abdelgawad, M.R.; Fekry, A.E.; Edrees, G.; Ali, M.A.; Ghareeb, N.A.

    2008-01-01

    Transforming growth factor beta-1 (TGF β1) is an important mediator which controls liver cell proliferation and replication. The relation between TGF β1, Alpha-fetoprotein (AFP) and clinically thought hepatocellular carcinoma (HCC) in rats were investigated to clarify the clinical value of measuring peripheral serum TGF β1 and AFP in evaluation of HCC. Peripheral serum TGF β1 and AFP were measured during chemically induced hepato carcinogenesis. Male rats were given a genotoxic compound diethylnitrosamine (DEN) in drinking water for 149 days with control receiving drinking water only. Animals were killed at different times intervals 54, 86 and 149 days, serum TGF β1 levels were measured by, Enzyme Linked Immunosorbent Assay (ELISA) and AFP levels were assayed by immunoradiometric assay (IRMA). In DEN treated rats 54 days, there was mild portal tract inflammatory cellular infiltrate, serum TGF β1 and AFP levels were both significantly elevated above control (P>0.05 and P<0.001). At 86 days there were moderate inflammation (portal and peri portal), serum TGF β1 and AFP levels were significantly increased, (P<0.001). At 149 days typical HCC were present in ten of ten rats and serum TGF β1 and AFP were both significantly elevated compared with controls, (P<0.001). It can be concluded that serum TGF β1 and AFP levels are elevated during chemically induced HCC and have roles during the stages of process (initiation, promotion and progression); both serum TGF β1 and AFP levels can be used in parallel as a non invasive tumor markers for early diagnosis and prognosis of HCC

  13. A novel mutation in PNPLA2 leading to neutral lipid storage disease with myopathy.

    Science.gov (United States)

    Ash, Daniel B; Papadimitriou, Dimitra; Hays, Arthur P; Dimauro, Salvatore; Hirano, Michio

    2012-09-01

    Mutations in PNPLA2, a gene encoding adipose triglyceride lipase, lead to neutral lipid storage disease with myopathy. To report the clinical and molecular features of a case of neutral lipid storage disease with myopathy resulting from a novel mutation in PNPLA2. Case report. University hospital. A 65-year-old man with progressive muscle weakness and high serum creatine kinase levels. Direct sequencing of the PNPLA2 gene. Identification of a novel homozygous mutation in the patient's PNPLA2 gene confirmed the suspected diagnosis of neutral lipid storage disease with myopathy. Screening of the PNPLA2 gene should be considered for patients presenting with high levels of creatine kinase, progressive muscle weakness, and systemic lipid accumulation. The presence of Jordans anomaly can be a strong diagnostic clue.

  14. Neutralizing and non-neutralizing monoclonal antibodies against dengue virus E protein derived from a naturally infected patient

    Directory of Open Access Journals (Sweden)

    Isern Sharon

    2010-02-01

    Full Text Available Abstract Background Antibodies produced in response to infection with any of the four serotypes of dengue virus generally provide homotypic immunity. However, prior infection or circulating maternal antibodies can also mediate a non-protective antibody response that can enhance the course of disease in a subsequent heterotypic infection. Naturally occurring human monoclonal antibodies can help us understand the protective and pathogenic roles of the humoral immune system in dengue virus infection. Results Epstein-Barr Virus (EBV transformation of B cells isolated from the peripheral blood of a human subject with previous dengue infection was performed. B cell cultures were screened by ELISA for antibodies to dengue (DENV envelope (E protein. ELISA positive cultures were cloned by limiting dilution. Three IgG1 human monoclonal antibodies (HMAbs were purified and their binding specificity to E protein was verified by ELISA and biolayer interferometry. Neutralization and enhancement assays were conducted in epithelial and macrophage-like cell lines, respectively. All three HMAbs bound to E from at least two of the four DENV serotypes, one of the HMAbs was neutralizing, and all were able to enhance DENV infection. Conclusions HMAbs against DENV can be successfully generated by EBV transformation of B cells from patients at least two years after naturally acquired DENV infections. These antibodies show different patterns of cross-reactivity, neutralizing, and enhancement activity.

  15. Comparison of multiple assays for detecting human antibodies directed against antigens on normal and malignant tissue culture cells

    International Nuclear Information System (INIS)

    Rosenberg, S.A.; Schwarz, S.; Anding, H.; Hyatt, C.; Williams, G.M.; Johns Hopkins Univ., Baltimore, Md.

    1977-01-01

    Four separate assays of human antibody reactivity to four separate normal and malignant human tissue culture cells lines from two patients have been evaluated using a single highly-reactive allogeneic serum. The visual end-point cytolysis assay and the chromium-51 release assay were equally sensitive in measuring complement mediated antibody cytotoxicity and both were far more sensitive than a trypan blue dye exclusion assay. The assay of antibody reactivity by hemadsorption technique was about 10 times more sensitive than any of the cytotoxicity assays. This latter assay measures only IgG antibody however. These assays showed that cell lines from different patients may differ greatly in 'reactivity' to an allogeneic serum and emphasized the importance of utilizing tumor and normal cells from the same patient when using tissue culture cells to search for tumor specific reactivity. These observations emphasize the importance of utilizing multiple assays against paired normal and malignant cells from the same patient to be certain of the specificity and magnitude of the measured antibody

  16. An ARGS-aggrecan assay for analysis in blood and synovial fluid

    DEFF Research Database (Denmark)

    Larsson, S; Lohmander, Stefan; Struglics, A

    2014-01-01

    OBJECTIVE: To validate a modified ligand-binding assay for the detection of aggrecanase generated aggrecan fragments with the ARGS neoepitope in synovial fluid (SF) and blood, and to verify the identity of aggrecan fragments found in blood. DESIGN: An enzyme-linked immunosorbent assay (ELISA....... Aggrecan was purified from serum and plasma pools and analysed by Western blot. RESULTS: The limits of quantification for the ARGS-aggrecan assay was between 0.2 and 0.025 pmol ARGS/ml, and the sensitivity of the assay was improved two-fold compared to when using a standard purified from human donors...... similar, and correlated (r(S) = 0.773, P assay is highly sensitive and suited for analysis...

  17. Analytical interference by contrast agents in biochemical assays

    DEFF Research Database (Denmark)

    Otnes, Sigrid; Fogh-Andersen, Niels; Rømsing, Janne

    2017-01-01

    Objective. To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods. The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29...... most frequently performed biochemical assays. One-day-old plasma, serum, and whole blood were spiked with doses of each agent such that the gadolinium agents and the iodine agents reached concentrations of 0.5mMand 12mg iodine/mL, respectively. Subsequently, 12 assays were reexamined using 1/2 and 1...

  18. X-ray induced DNA double strand break production and repair in mammalian cells as measured by neutral filter elution

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, M O; Kohn, K W [National Institutes of Health, Bethesda, MD (USA)

    1979-10-01

    A neutral filter elution method was used for detecting DNA double strand breaks in mouse L1210 cells after X-ray. The assay detected the number of double strand breaks induced by as little as 1000 rad of X-ray. The rate of DNA elution through the filters under neutral conditions increased with X-ray dose. Certain conditions for deproteinization, pH, and filter type were shown to increase the assay's sensitivity. Hydrogen peroxide and Bleomycin also induced apparent DNA double strand breaks, although the ratios of double to single strand breaks varied from those produced by X-ray. The introduction of double strand cuts by HpA I restriction endonuclease in DNA lysed on filters resulted in a rapid rate of elution under neutral conditions, implying that the method can detect double strand breaks if they exist in the DNA. The eluted DNA banded with a double stranded DNA marker in cesium chloride. This evidence suggested that the assay detected DNA double strand breaks. L1210 cells were shown to rejoin most of the DNA double strand breaks induced by 5-10 krad of X-ray with a half-time of about 40 minutes. (author).

  19. Comparison of serum and salivary antibodies in children vaccinated with oral live or parenteral inactivated poliovirus vaccines of different antigen concentrations.

    Science.gov (United States)

    Zaman, S; Carlsson, B; Jalil, F; Mellander, L; Van Wezel, A L; Böttiger, M; Hanson, L A

    1991-12-01

    A new antigen-rich inactivated poliovirus vaccine (IPV) in ordinary (IPV1), double (IPV2) and quadruple (IPV4) antigen concentrations was given in 2 doses to 6 and 18 week old Pakistani infants. The immune responses to poliovirus types 1 and 3 were compared to those in infants given three doses of oral poliovirus vaccine (OPV) at 6, 12 and 18 weeks of age. Enzyme-linked immunosorbent assay, ELISA, was used to estimate IgG and IgA in serum and secretory IgA (SIgA) in saliva. Two to three years later, a follow-up of the serum antibody response was carried out in the same infants using a microneutralization test. Serum IgG antibody responses to poliovirus type 1 antigen after two doses of IPV1, IPV2 and IPV4 were not significantly higher than the response after three doses of OPV at 21 weeks of age (p greater than 0.05). The serum IgG responses to poliovirus type 3 were similar to those against type 1 in all the groups. Mean neutralizing antibody titres to poliovirus type 1 was significantly higher in the IPV2 group than the rest of the groups (p less than 0.01). For type 3, these titres were highest but not significantly, in the IPV4 group (p greater than 0.05). This study shows that two doses of a new antigen-rich IPV can give similar immediate serum antibody responses as OPV but higher late responses. SIgA antibodies in saliva were more efficiently induced by OPV after three doses than after 2 doses of IPV (p less than 0.05).

  20. Inositol and hepatic lipidosis. II. Effect of inositol supplementation and time from parturition on serum insulin, thyroxine and triiodothyronine and their relationship to serum and liver lipids in dairy cows.

    Science.gov (United States)

    Gerloff, B J; Herdt, T H; Wells, W W; Nachreiner, R F; Emery, R S

    1986-06-01

    Percutaneous liver biopsies and blood samples were obtained from 80 dairy cows in nine Michigan herds over the peripartum period. Thirty-nine cows were fed 17 g of supplemental inositol and 41 were fed a placebo. Liver biopsies were assayed for total myoinositol and triglyceride (TG) concentrations. Blood samples were assayed for serum dextran precipitable cholesterol, nonesterified fatty acids (NEFA), insulin, thyroxine (T4), free (FT4), triiodothyronine (T3) and free T3 (FT3) concentrations. Serum concentrations of insulin and the thyroid hormones decreased near parturition, with lowest concentrations occurring in the immediate postpartum period. Concentrations of T3 correlated well with T4, and the concentrations of free thyroid hormones reflected concentrations of total thyroid hormones. The percentage of hormone in the free fraction remained constant over time. Serum insulin, T3 and T4 were negatively correlated with serum NEFA and liver TG concentrations. Thyroid hormone concentrations were positively correlated with serum dextran precipitable cholesterol concentrations. Inositol supplementation was associated with reduced circulating T3 and FT3 concentrations, but not T4 and FT4 concentrations. Changes in hormone concentrations at parturition and their relationship to liver TG and serum NEFA concentrations were consistent with a metabolic adaptation by the dairy cow to the negative energy balance of early lactation.

  1. Importance of Neutralizing Monoclonal Antibodies Targeting Multiple Antigenic Sites on the Middle East Respiratory Syndrome Coronavirus Spike Glycoprotein To Avoid Neutralization Escape

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lingshu; Shi, Wei; Chappell, James D.; Joyce, M. Gordon; Zhang, Yi; Kanekiyo, Masaru; Becker, Michelle M.; van Doremalen, Neeltje; Fischer, Robert; Wang, Nianshuang; Corbett, Kizzmekia S.; Choe, Misook; Mason, Rosemarie D.; Van Galen, Joseph G.; Zhou, Tongqing; Saunders, Kevin O.; Tatti, Kathleen M.; Haynes, Lia M.; Kwong, Peter D.; Modjarrad, Kayvon; Kong, Wing-Pui; McLellan, Jason S.; Denison, Mark R.; Munster, Vincent J.; Mascola, John R.; Graham, Barney S.; Gallagher, Tom

    2018-03-07

    ABSTRACT

    Middle East respiratory syndrome coronavirus (MERS-CoV) causes a highly lethal pulmonary infection with ~35% mortality. The potential for a future pandemic originating from animal reservoirs or health care-associated events is a major public health concern. There are no vaccines or therapeutic agents currently available for MERS-CoV. Using a probe-based single B cell cloning strategy, we have identified and characterized multiple neutralizing monoclonal antibodies (MAbs) specifically binding to the receptor-binding domain (RBD) or S1 (non-RBD) regions from a convalescent MERS-CoV-infected patient and from immunized rhesus macaques. RBD-specific MAbs tended to have greater neutralizing potency than non-RBD S1-specific MAbs. Six RBD-specific and five S1-specific MAbs could be sorted into four RBD and three non-RBD distinct binding patterns, based on competition assays, mapping neutralization escape variants, and structural analysis. We determined cocrystal structures for two MAbs targeting the RBD from different angles and show they can bind the RBD only in the “out” position. We then showed that selected RBD-specific, non-RBD S1-specific, and S2-specific MAbs given prophylactically prevented MERS-CoV replication in lungs and protected mice from lethal challenge. Importantly, combining RBD- and non-RBD MAbs delayed the emergence of escape mutations in a cell-based virus escape assay. These studies identify MAbs targeting different antigenic sites on S that will be useful for defining mechanisms of MERS-CoV neutralization and for developing more effective interventions to prevent or treat MERS-CoV infections.

    IMPORTANCEMERS-CoV causes a highly lethal respiratory infection for which no vaccines or antiviral therapeutic options are currently available. Based on continuing exposure from established reservoirs in dromedary camels and bats, transmission of MERS-CoV into humans and future outbreaks are expected. Using

  2. Production of antiserum and development of radioimmunoassay for progesterone measurement in serum

    International Nuclear Information System (INIS)

    Abdalla, O.M; Abbas, S.H.

    2004-03-01

    The anti progesterone antibody was obtained by injection of local sudanese sheep (bevies arias) intramuscularly and subcutaneously using 11-a-hydroxy progesterone conjugated with bovine serum albumin and emulsified in friend's adjuvant. The blood samples collected one week after the 3 rd injection was tested for anti-progesterone antibodies. Different dilutions of antisera in Pbs containing 0.0.1 % BSA and 0.1 % Na N 3 (Ph 7.4) were made. Using these dilutions, polystyrene balls of 6.4 mm diameter were coated with a coating volume of 500 μ1/bead.The antibody dilution of 1/200000 was selected and used for assembling a kit to measure progesterone level in serum. Optimization of the assay condition resulted in the following recipes: Fifty μ1 of standard or Qc (Low, normal and high) from Bio Rad for 2 hours. The reaction medium aspirated, washed twice and read for 100 seconds in gamma counter. Assay validation tests including Linearity, recovery, reproducibility and comparability were done. In regards to linearity, the measured concentrations of progesterone in serum samples were plotted against the expected values. The correlation coefficient was 0.997 and a linear regression equation was Y=1.1019+0.9895 X. The mean recovery was 96.86% of the sample replicates ranged from 0.2% to 6%. between assay reproducibility was assessed fro the results obtained from 3 samples which were used for quality control in different assays. The results obtained were in the reference range and were close to each other. Comparison between local and American Dpc reagents for progesterone determination in serum showed high correlation high correlation where r 0.9492.(Author)

  3. Maternal serum levels of adiponectin in preeclampsia

    International Nuclear Information System (INIS)

    Khosrowbeygi, A.; Ahmadvand, H.

    2009-01-01

    The results of the serum levels of adiponectin in pre eclamptic patients are conflicting. Objective: The aim of the present study was to assess serum levels of adiponectin in women with pre eclampsia compared with healthy pregnant women. Methods: A cross-sectional study was designed. The case group consisted of women with pre eclampsia (n=30). The control group consisted of 30 matched normal pregnant women. Serum levels of adiponectin were assessed using enzyme-linked immunosorbent assay method. Results: Serum levels of adiponectin were significantly higher in the pre eclamptic group than those in the normal control group. In the pre eclamptic patients serum levels of adiponectin showed a significant negative correlation with body mass index while no correlation was found in the normal pregnant women. In women with pre eclampsia, levels of adiponectin were decreased significantly in the overweight women compared with normal weight women, while in the control group no significant difference was observed. Conclusion: In conclusion, elevation of adiponectin levels might be a physiological feedback response to minimize endothelial dysfunction in pre eclamptic patients. (author)

  4. A sensitive radioimmunoassay for measurements of 3,3'- diiodothyronine in unextracted serum

    International Nuclear Information System (INIS)

    Laurberg, P.

    1978-01-01

    A radioimmunoassay for measurements of 3,3'-diiodothyronine (3,3'-T2) in unextracted serum is described. Antisera to 3,3'-T2 were produced by immunization of rabbits with 3,3'-T2 coupled to human serum albumin. Scatchard plot analysis of the chosen antiserum gave an effective equilibrium constant of 1.1x 10 11 l/mol. The 3,3'-T2 binding capacity in undiluted serum was calculated to be 9.1 mmol/m. Monolabelled ( 125 I)3,3'T2 having a specific activity of 3800 mCi/mg was synthetized from 3-monoiodothyronine. The lowest concentration of standard inducing a consistent fall in per cent bound ( 125 I)3,3'-T2 was 6.0 pmol/l (0.24fmol/tube). Triiodothyronine (T3) cross-reacted significantly in the assay. At 50% inhibition of binding of ( 125 I)3,3'-T2, the cross-reaction was 0.29% (mol/mol), but at the low physiological concentrations of T3 it amounted to approximately 1%. T3 cross-reaction was corrected for in every assay. The interference of 3,3'-T2 binding proteins in serum was precluded by adding 8-anilino-1-napthalenesulphonic acid (ANS). Mean 3,3'-T2 concentrations were 38.9 pmol/l in fourteen normal young females and 48.9 pmol/l in fifteen normal young males. When 3,3'-T2 was measured(1) in extracts of serum, (2) in assays where T3 was added to standards in amounts equivalent to those present in the samples and T3 correction omitted, and (3) using a different 3,3'-T2 antibody, similar levels of 3,3'-T2 were found in normal serum. (Auth.)

  5. Enterovirus 71 Neutralizing Antibodies Seroepidemiological Research among Children in Guangzhou, China between 2014 and 2015: A Cross-Sectional Study.

    Science.gov (United States)

    Zhang, Dingmei; Chen, Yan; Chen, Xiashi; He, Zhenjian; Zhu, Xun; Hao, Yuantao

    2017-03-20

    A hand-foot-mouth disease outbreak occurred in 2014 around Guangdong. The purpose of this study was investigating the status and susceptibility of infectious neutralizing antibodies to enterovirus 71 among children so as to provide scientific evidence for the population immunity level of hand-foot-mouth disease and prepare for enterovirus 71 vaccination implementation. Serum specimens were collected from children in communities from January 2014 to March 2015 in Guangzhou. A total of 197 serum samples from children 1-5 years old were collected for this cross-sectional study via non-probabilistic sampling from the database of Chinese National Science and Technique Major Project. Neutralization activity was measured via micro neutralization test in vitro. The positive rate of enterovirus 71 neutralizing antibodies was 59.4%, whereas the geometric mean titre was 1:12.7. A statistically significant difference in true positive rates was found between different age groups but not between different genders. Being the most susceptible population of hand-foot-mouth disease, children under 3 years of age are more likely to be infected with enterovirus 71, and the immunity of children increases with increasing age. Further cohort studies should be conducted, and measures for prevention and vaccination should be taken.

  6. Enterovirus 71 Neutralizing Antibodies Seroepidemiological Research among Children in Guangzhou, China between 2014 and 2015: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Dingmei Zhang

    2017-03-01

    Full Text Available A hand-foot-mouth disease outbreak occurred in 2014 around Guangdong. The purpose of this study was investigating the status and susceptibility of infectious neutralizing antibodies to enterovirus 71 among children so as to provide scientific evidence for the population immunity level of hand-foot-mouth disease and prepare for enterovirus 71 vaccination implementation. Serum specimens were collected from children in communities from January 2014 to March 2015 in Guangzhou. A total of 197 serum samples from children 1–5 years old were collected for this cross-sectional study via non-probabilistic sampling from the database of Chinese National Science and Technique Major Project. Neutralization activity was measured via micro neutralization test in vitro. The positive rate of enterovirus 71 neutralizing antibodies was 59.4%, whereas the geometric mean titre was 1:12.7. A statistically significant difference in true positive rates was found between different age groups but not between different genders. Being the most susceptible population of hand–foot–mouth disease, children under 3 years of age are more likely to be infected with enterovirus 71, and the immunity of children increases with increasing age. Further cohort studies should be conducted, and measures for prevention and vaccination should be taken.

  7. On becoming neutral: effects of experimental neutralizing reconsidered.

    Science.gov (United States)

    van den Hout, M; van Pol, M; Peters, M

    2001-12-01

    Behaviour Research and Therapy 34 (1996) 889-898 found that writing out a negative thought produced anxiety and an urge to neutralize the thought, that instructing participants to neutralize the thought reduced anxiety/neutralization urge in the short run (i.e. within 2 min), but that in the control group 20 min without instruction was attended by the same reduction in anxiety/urge to neutralize ("natural decay"). The observations were made with pariticipants who scored high on "thought action fusion" and the experiment was set up as exerimental model of obsessions. We repeated the study with participants that were not selected on thought action fusion. All the findings reported by Behaviour Research and Therapy 34 (1996) 889-898 were replicated. Correlational analysis indicated that the strength of the effect was not related to scores on scales measuring "thought action fusion". Behaviour Research and Therapy 34 (1996) 889-898 did not assess whether non-neutralizing was followed by immediate reductions in distress. We did assess this and found that the larger part of the immediate reduction of distress after neutralization also occurs when no neutralization instruction is given. The effects of neutralization instructions in the present type of experiment are considerably less powerful than suggested earlier.

  8. First 25-hydroxyvitamin D assay for general chemistry analyzers.

    Science.gov (United States)

    Saida, Fakhri B; Chen, Xiaoru; Tran, Kiet; Dou, Chao; Yuan, Chong

    2015-03-01

    25-Hydroxyvitamin D [25(OH)D], the predominant circulating form of vitamin D, is an accurate indicator of the general vitamin D status of an individual. Because vitamin D deficiencies have been linked to several pathologies (including osteoporosis and rickets), accurate monitoring of 25(OH)D levels is becoming increasingly important in clinical settings. Current 25(OH)D assays are either chromatographic or immunoassay-based assays. These assays include HPLC, liquid chromatography-tandem mass spectrometry (LC-MS/MS), enzyme-immunosorbent, immunochemiluminescence, immunofluorescence and radioimmunoassay. All these assays use heterogeneous formats that require phase separation and special instrumentations. In this article, we present an overview of these assays and introduce the first homogeneous assay of 25(OH)D for use on general chemistry analyzers. A special emphasis is put on the unique challenges posed by the 25(OH)D analyte. These challenges include a low detection limit, the dissociation of the analyte from its serum transporter and the inactivation of various binding proteins without phase separation steps.

  9. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    International Nuclear Information System (INIS)

    Yang, S.Y.; Lan, C.B.; Chen, C.H.; Horng, H.E.; Hong, Chin-Yih; Yang, H.C.; Lai, Y.K.; Lin, Y.H.; Teng, K.S.

    2009-01-01

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  10. Independency of Fe ions in hemoglobin on immunomagnetic reduction assay

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S.Y. [MagQu Co. Ltd., Sindian City, Taipei County 231, Taiwan (China); Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Lan, C.B.; Chen, C.H. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Horng, H.E. [Institute of Electro-optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China)], E-mail: phyfv001@scc.ntnu.edu.tw; Hong, Chin-Yih [Department of Mechanical Engineering, Nan-Kai University of Technology, Nantau County, Taiwan (China)], E-mail: cyhong@nkut.edu.tw; Yang, H.C. [Department of Physics, National Taiwan University, Taipei 106, Taiwan (China)], E-mail: hcyang@phys.ntu.edu.tw; Lai, Y.K. [College of Life Sciences, National Tsing Hua University, Hsinchu City 300, Taiwan (China); Department of Bioresources, Da-Yeh University, Changhua 515, Taiwan (China); Lin, Y.H.; Teng, K.S. [Apex Biotechnology Co. Ltd., Hsinchu City 300, Taiwan (China)

    2009-10-15

    Immunomagnetic reduction (IMR), which involves measuring the reduction in the ac magnetic susceptibility of magnetic reagents, is due to the association between bio-functionalized magnetic nanoparticles and target bio-molecules. This has been demonstrated for assaying proteins in solutions free of Fe ions, such as serum. In this work, the validity of IMR assay for samples rich in Fe ions like hemoglobin (Hb) is investigated. According to the results, there is no magnetic signal contributed by Fe-ion-rich Hb. Furthermore, the results show a high sensitivity in assaying hemoglobin A1c (HbA1c) by using IMR.

  11. Ensaio imunoenzimático comercial no diagnóstico sorológico das infecções por herpesvírus bovino 1 A commercial enzyme immune assay in serodiagnosis of bovine herpesvirus 1 infections

    Directory of Open Access Journals (Sweden)

    Kerlei Cristina Médici

    2000-04-01

    Full Text Available Avaliou-se o desempenho de um ensaio imunoenzimático, obtido de fonte comercial, na identificação de anticorpos contra herpesvírus bovino tipo 1 (BHV-1, induzidos tanto por infecção natural quanto por vacinação, em 1000 amostras de soros sangüíneos de bovinos. A análise comparativa dos resultados obtidos no sistema avaliado e na técnica padrão de soroneutralização mostrou uma concordância de 97,05% (K=0,94 entre as duas metodologias de diagnóstico sorológico.The performance of a commercial immune assay in the identification antibody of natural infection or vaccination against bovine herpesvirus type 1 (BHV-1 in 1000 samples of bovine serum was evaluated. The comparative analysis from the result of the evaluated system and standard serum neutralization technique showed a rate of agreement of 97.05% (K=0.94 between the two serologic diagnotic methods.

  12. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  13. Emerging Technologies and Generic Assays for the Detection of Anti-Drug Antibodies

    Directory of Open Access Journals (Sweden)

    Michael A. Partridge

    2016-01-01

    Full Text Available Anti-drug antibodies induced by biologic therapeutics often impact drug pharmacokinetics, pharmacodynamics response, clinical efficacy, and patient safety. It is critical to assess the immunogenicity risk of potential biotherapeutics in producing neutralizing and nonneutralizing anti-drug antibodies, especially in clinical phases of drug development. Different assay methodologies have been used to detect all anti-drug antibodies, including ELISA, radioimmunoassay, surface plasmon resonance, and electrochemiluminescence-based technologies. The most commonly used method is a bridging assay, performed in an ELISA or on the Meso Scale Discovery platform. In this report, we aim to review the emerging new assay technologies that can complement or address challenges associated with the bridging assay format in screening and confirmation of ADAs. We also summarize generic anti-drug antibody assays that do not require drug-specific reagents for nonclinical studies. These generic assays significantly reduce assay development efforts and, therefore, shorten the assay readiness timeline.

  14. Immunocapture loop-mediated isothermal amplification assays for the detection of canine parvovirus.

    Science.gov (United States)

    Sun, Yu-Ling; Yen, Chon-Ho; Tu, Ching-Fu

    2017-11-01

    A loop-mediated isothermal amplification (LAMP) assay was used for rapid canine parvovirus (CPV) diagnosis. To reduce the time required and increase the sensitivity of the assay, an immunocapture (IC) technique was developed in this study to exclude the DNA extraction step in molecular diagnostic procedures for CPV. A polyclonal rabbit anti-CPV serum was produced against VP2-EpC that was cloned via DNA recombination. The polyclonal anti-VP2-EpC serum was used for virus capture to prepare microtubes. IC-LAMP was performed to amplify a specific CPV target gene sequence from the CPV viral particles that were captured on the microtubes, and the amplicons were analyzed using agarose electrophoresis or enzyme-linked immunosorbent assay (IC-LAMP-ELISA) and lateral-flow dipstick (IC-LAMP-LFD). The detection sensitivities of IC-LAMP, IC-LAMP-ELISA, and IC-LAMP-LFD were 10 -1 , 10 -1 , and 10 -1 TCID 50 /mL, respectively. Using the IC-LAMP-ELISA and IC-LAMP-LFD assays, the complete CPV diagnostic process can be achieved within 1.5h. Both of the developed IC-LAMP-based assays are simple, direct visual and efficient techniques that are applicable to the detection of CPV. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Study of the role of serum folic acid in atopic dermatitis: A correlation with serum IgE and disease severity

    Directory of Open Access Journals (Sweden)

    Maha A Shaheen

    2011-01-01

    Full Text Available Background : Most atopic dermatitis (AD patients have elevated serum immunoglobulin E (IgE. Impaired folic acid (FA metabolism was found to reduce the intracellular methyl donor pool, associated with a higher prevalence of atopy. Aim : To assess serum IgE and FA in AD patients and to correlate their levels with the disease severity, and with each other. Materials and Methods : Twenty patients with AD were assessed for serum FA and IgE, compared with 20 age- and sex-matched controls. Patients were classified into three groups (mild, moderate, and severe AD based on clinical severity according to Nottingham index. In both patients and controls, serum IgE was measured using Enzyme-linked immunosorbent assay technique and serum FA was measured using Microparticle Enzyme Immunoassay technique. Results : Serum FA levels were lower in AD patients compared with controls, but the difference was not statistically significant. FA levels did not show statistically significant difference among disease severity groups and did not correlate with serum IgE levels. On the other hand, serum IgE levels were significantly elevated in AD patients compared with controls, and among AD patients, its levels were significantly elevated in severe AD compared with mild and moderate disease. Conclusion : Serum IgE is useful in assessment of AD severity and activity. FA contribution to AD needs further investigations.

  16. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays

    OpenAIRE

    Saleh, Lanja; Mueller, Daniel; von Eckardstein, Arnold

    2015-01-01

    BACKGROUND: We evaluated the analytical and clinical performance of the new Lumipulse® G 25-OH vitamin D assay from Fujirebio, and compared it to a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method and three other commercial automated assays. METHODS: Total 25 hydroxy vitamin D (25(OH)D) levels were measured in 100 selected serum samples from our routine analysis with Fujirebio 25(OH)D assay. The results were compared with those obtained with LC-MS/MS and three other automat...

  17. Evaluation of Multiplexed Foot-and-Mouth Disease Nonstructural Protein Antibody Assay Against Standardized Bovine Serum Panel

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, J; Parida, S; Clavijo, A

    2007-05-14

    Liquid array technology has previously been used to show proof-of-principle of a multiplexed non structural protein serological assay to differentiate foot-and-mouth infected and vaccinated animals. The current multiplexed assay consists of synthetically produced peptide signatures 3A, 3B and 3D and recombinant protein signature 3ABC in combination with four controls. To determine diagnostic specificity of each signature in the multiplex, the assay was evaluated against a naive population (n = 104) and a vaccinated population (n = 94). Subsequently, the multiplexed assay was assessed using a panel of bovine sera generated by the World Reference Laboratory for foot-and-mouth disease in Pirbright, UK. This sera panel has been used to assess the performance of other singleplex ELISA-based non-structural protein antibody assays. The 3ABC signature in the multiplexed assay showed comparative performance to a commercially available non-structural protein 3ABC ELISA (Cedi test{reg_sign}) and additional information pertaining to the relative diagnostic sensitivity of each signature in the multiplex is acquired in one experiment. The encouraging results of the evaluation of the multiplexed assay against a panel of diagnostically relevant samples promotes further assay development and optimization to generate an assay for routine use in foot-and-mouth disease surveillance.

  18. Serum thyroglobulin in the management of patients with thyroid cancer

    International Nuclear Information System (INIS)

    Barsano, C.P.; Skosey, C.; DeGroot, L.J.; Refetoff, S.

    1982-01-01

    We have reviewed our experience with the management of patients with thyroid cancer to assess the potential benefits of employing the serum thyroglobulin assay in patient management programs and to determine the optimal conditions for this application. Serum thyroglobulin levels were found to be more reliable when obtained from hypothyroid patients. Levels of thyroglobulin greater than 10 ng/mL appeared to be abnormally elevated in both thyroidectomized patients prior to radioactive iodine therapy (group 1) and in thyroidectomized patients after radioactive iodine therapy (group 2). Elevated thyroglobulin levels were found to be useful indicators of the presence of metastatic disease, whereas normal thyroglobulin levels were reliable indicators of the absence of metastases. In group 1 patients, elevated thyroglobulin levels reliably predicted the presence of important total body scan uptake. In group 2 patients, normal thyroglobulin levels reliably predicted the absence of total body scan uptake. The serum thyroglobulin assay can substantially reduce the need for repetitive total body scanning in the follow-up of group 2 patients with thyroid cancer

  19. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay*

    Science.gov (United States)

    DALBY, TINE; SØRENSEN, CHARLOTTE; PETERSEN, JESPER WESTPHAL; KROGFELT, KAREN ANGELIKI

    2010-01-01

    Dalby T, Sørensen C, Petersen JW, Krogfelt KA. Pertussis serology: assessment of IgG anti-PT ELISA for replacement of the CHO cell assay. APMIS 2010; 118: 968–72. Two types of serological assays are commonly used for the assessment of pertussis vaccine-induced antibodies; the Chinese hamster ovary cell (CHO cell) assay and the immunoglobulin G (IgG) anti pertussis toxin (PT) enzyme-linked immunosorbent assay (IgG anti-PT ELISA). Recently, both the techniques have been modified to improve performance with sera with interfering activity (CHO cell assay) or with heat-treated sera (IgG anti-PT ELISA). These two improved techniques were compared by the analysis of 100 individual serum samples from a previous clinical trial and 213 sera from a longitudinal serum collection from 20 Danish adults recently vaccinated with the Danish acellular pertussis vaccine. The comparison showed a significant linear correlation between the results of the two assays with a p-value of ELISA can be used as a replacement for the often troublesome and time-consuming CHO cell assay for the measurement of vaccine-induced human antibodies to PT. PMID:21091778

  20. Values of serum AFP, GGTⅡ and GP73 in diagnosis of primary hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    ZHU Chen

    2014-10-01

    Full Text Available ObjectiveTo explore the early diagnostic values of serum alpha-fetoprotein (AFP, gamma-glutamyltransferase Ⅱ (GGTⅡ, and Golgi protein 73 (GP73 in patients with primary hepatocellular carcinoma (PHC. MethodsThe serum specimens of 100 patients with liver diseases (50 cases of hepatitis and liver cirrhosis and 50 cases of PHC and 50 healthy people were collected in our hospital from February 2013 to February 2014. Electrochemical luminescence technique, specific immuno-membrane adsorption assay, and enzyme-linked immunosorbent assay were used to measure the serum levels of AFP, GGTⅡ, and GP73. Comparison of continuous data between multiple groups was made by analysis of variance, and comparison between two groups was made by q test. The receiver operating characteristic (ROC curves of single or combined test results were made, and the areas under the ROC curves (AUCs were calculated. The sensitivity, specificity, and AUCs of AFP, GGTⅡ, GP73, and the combined test were analyzed and compared. ResultsThe level of serum GGTⅡ in the PHC group was significantly different compared with those in the other two groups (F=16.224, P<0.05, but there was no significant difference between the normal group and the hepatitis and liver cirrhosis group (P>0.05. Significant differences in serum levels of AFP and GP73 were observed by paired comparison between the PHC group, hepatitis and liver cirrhosis group, and normal group (F=193.128, F=20.231, P<0.05 for both. When assayed alone, the specificities of GP73, GGTⅡ, and AFP were 69%, 64% and 51%, respectively, and the sensitivities were 92%, 84%, and 76%, respectively. In combined test, the specificity was 94.6% and the sensitivity was 98.8%. ConclusionThe GP73 test is the best performer in the single assays. Combined test of serum AFP, GGTⅡ, and GP73 shows a good diagnostic value for PHC with greatly improved specificity and sensitivity.

  1. Structural basis for type VI secreted peptidoglycan dl-endopeptidase function, specificity and neutralization in Serratia marcescens

    Energy Technology Data Exchange (ETDEWEB)

    Srikannathasan, Velupillai; English, Grant [University of Dundee, Dundee DD1 5EH, Scotland (United Kingdom); Bui, Nhat Khai [Newcastle University, Newcastle upon Tyne NE2 4HH (United Kingdom); Trunk, Katharina; O’Rourke, Patrick E. F.; Rao, Vincenzo A. [University of Dundee, Dundee DD1 5EH, Scotland (United Kingdom); Vollmer, Waldemar [Newcastle University, Newcastle upon Tyne NE2 4HH (United Kingdom); Coulthurst, Sarah J., E-mail: s.j.coulthurst@dundee.ac.uk; Hunter, William N., E-mail: s.j.coulthurst@dundee.ac.uk [University of Dundee, Dundee DD1 5EH, Scotland (United Kingdom)

    2013-12-01

    Crystal structures of type VI secretion system-associated immunity proteins, a peptidoglycan endopeptidase and a complex of the endopeptidase and its cognate immunity protein are reported together with assays of endopeptidase activity and functional assessment. Some Gram-negative bacteria target their competitors by exploiting the type VI secretion system to extrude toxic effector proteins. To prevent self-harm, these bacteria also produce highly specific immunity proteins that neutralize these antagonistic effectors. Here, the peptidoglycan endopeptidase specificity of two type VI secretion-system-associated effectors from Serratia marcescens is characterized. These small secreted proteins, Ssp1 and Ssp2, cleave between γ-d-glutamic acid and l-meso-diaminopimelic acid with different specificities. Ssp2 degrades the acceptor part of cross-linked tetratetrapeptides. Ssp1 displays greater promiscuity and cleaves monomeric tripeptides, tetrapeptides and pentapeptides and dimeric tetratetra and tetrapenta muropeptides on both the acceptor and donor strands. Functional assays confirm the identity of a catalytic cysteine in these endopeptidases and crystal structures provide information on the structure–activity relationships of Ssp1 and, by comparison, of related effectors. Functional assays also reveal that neutralization of these effectors by their cognate immunity proteins, which are called resistance-associated proteins (Raps), contributes an essential role to cell fitness. The structures of two immunity proteins, Rap1a and Rap2a, responsible for the neutralization of Ssp1 and Ssp2-like endopeptidases, respectively, revealed two distinct folds, with that of Rap1a not having previously been observed. The structure of the Ssp1–Rap1a complex revealed a tightly bound heteromeric assembly with two effector molecules flanking a Rap1a dimer. A highly effective steric block of the Ssp1 active site forms the basis of effector neutralization. Comparisons with Ssp2–Rap2

  2. Structural basis for type VI secreted peptidoglycan dl-endopeptidase function, specificity and neutralization in Serratia marcescens

    International Nuclear Information System (INIS)

    Srikannathasan, Velupillai; English, Grant; Bui, Nhat Khai; Trunk, Katharina; O’Rourke, Patrick E. F.; Rao, Vincenzo A.; Vollmer, Waldemar; Coulthurst, Sarah J.; Hunter, William N.

    2013-01-01

    Crystal structures of type VI secretion system-associated immunity proteins, a peptidoglycan endopeptidase and a complex of the endopeptidase and its cognate immunity protein are reported together with assays of endopeptidase activity and functional assessment. Some Gram-negative bacteria target their competitors by exploiting the type VI secretion system to extrude toxic effector proteins. To prevent self-harm, these bacteria also produce highly specific immunity proteins that neutralize these antagonistic effectors. Here, the peptidoglycan endopeptidase specificity of two type VI secretion-system-associated effectors from Serratia marcescens is characterized. These small secreted proteins, Ssp1 and Ssp2, cleave between γ-d-glutamic acid and l-meso-diaminopimelic acid with different specificities. Ssp2 degrades the acceptor part of cross-linked tetratetrapeptides. Ssp1 displays greater promiscuity and cleaves monomeric tripeptides, tetrapeptides and pentapeptides and dimeric tetratetra and tetrapenta muropeptides on both the acceptor and donor strands. Functional assays confirm the identity of a catalytic cysteine in these endopeptidases and crystal structures provide information on the structure–activity relationships of Ssp1 and, by comparison, of related effectors. Functional assays also reveal that neutralization of these effectors by their cognate immunity proteins, which are called resistance-associated proteins (Raps), contributes an essential role to cell fitness. The structures of two immunity proteins, Rap1a and Rap2a, responsible for the neutralization of Ssp1 and Ssp2-like endopeptidases, respectively, revealed two distinct folds, with that of Rap1a not having previously been observed. The structure of the Ssp1–Rap1a complex revealed a tightly bound heteromeric assembly with two effector molecules flanking a Rap1a dimer. A highly effective steric block of the Ssp1 active site forms the basis of effector neutralization. Comparisons with Ssp2–Rap2

  3. Spontaneous and cytokine induced basophil adhesion evaluated by microtiter assay

    DEFF Research Database (Denmark)

    Quan, Sha; Poulsen, Lars K; Reimert, Claus Michael

    2002-01-01

    We have developed a microtiter assay for evaluating basophil spontaneous adhesion to extracellular matrix (ECM) proteins exemplified by fibronectin and cytokine induced basophil adhesion to bovine serum albumin (BSA). The percentage of basophils adhering to either ECM or BSA was quantified...

  4. Detection and quantification of serum or plasma HCV RNA: mini review of commercially available assays.

    Science.gov (United States)

    Le Guillou-Guillemette, Helene; Lunel-Fabiani, Francoise

    2009-01-01

    The treatment schedule (combination of compounds, doses, and duration) and the virological follow-up for management of antiviral treatment in patients chronically infected by HCV is now well standardized, but to ensure good monitoring of the treated patients, physicians need rapid, reproducible, and sensitive molecular virological tools with a wide range of detection and quantification of HCV RNA in blood samples. Several assays for detection and/or quantification of HCV RNA are currently commercially available. Here, all these assays are detailed, and a brief description of each step of the assay is provided. They are divided into two categories by method: those based on signal amplification and those based on target amplification. These two categories are then divided into qualitative, quantitative, and quantitative detection assays. The real-time reverse-transcription polymerase chain reaction (RT-PCR)-based assays are the most promising strategy in the HCV virological area.

  5. Determination of serum neuron specific enolase and glutathion S transferases levels in patients with acute cerebral infarction and its clinical significance

    International Nuclear Information System (INIS)

    Guo Jianyi; Lu Tianhe; Bao Yanmei

    2002-01-01

    Objective: To evaluate the variation of serum neuron specific enolase (NSE) and glutathion S transferases (GST) levels in patients with cerebral infarction and its clinical significance. Methods: The serum levels of NSE in cerebral infarction patients were determined with immunoradiometric assay (IRMA), and the serum level of GST were determined by enzyme immuno sandwich assay (ELISA). Results: Serum NSE levels linked in patients were significantly higher (p<0.01) and GST serum levels were significantly lower (p < 0.01) within 3 days after onset of disease than those at two weeks and those in the controls. There was a positive correlation between serum NSE levels and neurological deficit scores (p < 0.001) and a negative correlation with serum GST levels (p < 0.05). There was also a close relationship between the serum NSE levels and the volume of infarction (p < 0.001). Conclusion: There was a close relationship between the Serum levels of NSE, GST and clinical features of Patients in the early stage of cerebral infarction

  6. Serum total antioxidant capacity in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Almira Hadžović-Džuvo

    2011-02-01

    Full Text Available Multiple sclerosis (MS is a chronic inflammatory disease of the central nervous system (CNS. It is characterized by loss of myelin, the fatty tissue that surrounds and protects nerve fibres allowing them to conduct electrical impulses. Recent data indicate that oxidative stress (OS plays a major role in the pathogenesis of multiple sclerosis (MS. The aim of this study was to estimate level of serum total antioxidative capacity in patients with multiple sclerosis. Our cross-sectional study included 33 patients with MS and 24 age and sex matched control subjects. All our patients had a Poser criteria for definite diagnostic categories of multiple sclerosis. Serum total antioxidant capacity (TAC was measured by quantitative colorimetric determination, using Total antioxidant Capacity-QuantiCromAntioxidant Assay Kit (BioAssay systems, USA; DTAC-100. Mean serum TAC in multiple sclerosis group of patients was 119.2 mM Trolox equivalents and was significantly lower (p<0.001 compared to the control group of subjects (167.1 mM Trolox equivalents. Our results showed that oxidative stress plays an important role in pathogenesis of multiple sclerosis. This finding, also, suggests the importance of antioxidants in diet and therapy of MS patients.

  7. Kinetics of Epstein-Barr Virus (EBV) Neutralizing and Virus-Specific Antibodies after Primary Infection with EBV

    Science.gov (United States)

    Bu, Wei; Hayes, Gregory M.; Liu, Hui; Gemmell, Lorraine; Schmeling, David O.; Radecki, Pierce; Aguilar, Fiona; Burbelo, Peter D.; Woo, Jennifer; Balfour, Henry H.

    2016-01-01

    Prospective studies of antibodies to multiple Epstein-Barr virus (EBV) proteins and EBV neutralizing antibodies in the same individuals before, during, and after primary EBV infection have not been reported. We studied antibody responses to EBV in college students who acquired primary EBV infection during prospective surveillance and correlated the kinetics of antibody response with the severity of disease. Neutralizing antibodies and enzyme-linked immunosorbent assay (ELISA) antibodies to gp350, the major target of neutralizing antibody, reached peak levels at medians of 179 and 333 days after the onset of symptoms of infectious mononucleosis, respectively. No clear correlation was found between the severity of the symptoms of infectious mononucleosis and the peak levels of antibody to individual viral proteins or to neutralizing antibody. In summary, we found that titers of neutralizing antibody and antibodies to multiple EBV proteins increase over many months after primary infection with EBV. PMID:26888186

  8. Milk minerals modify the effect of fat intake on serum lipid profile

    DEFF Research Database (Denmark)

    Lorenzen, Janne Kunchel; Jensen, Søren Krogh; Astrup, Arne

    2014-01-01

    Despite a high content of saturated fat, evidence from observational studies indicates that the consumption of dairy products may have a neutral effect or may be inversely associated with the risk of CVD. We aimed to examine whether milk minerals modify the effect of saturated fat on serum lipid...

  9. Serum amyloid P down-regulates CCL-1 expression, and inhibits ...

    African Journals Online (AJOL)

    Differentially expressed proteins in SAP-Tg and C57BL/6 serum were analyzed, and further determined by enzymelinked immunosorbent assay (ELISA) and ... SAP recombinant protein, ELISA results showed that CCL-1 secretion significantly ...

  10. Serum Endostatin Levels in Oral Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Maryam Mardani

    2018-05-01

    Full Text Available Introduction: Endostatin is a C-­terminal proteolytic fragment of collagen XVIII and, as with angiostatin and thrombospondin, is known as an anti­angiogenic agent. The aim of this study was to assess the level of serum endostatin in patients with oral squamous cell carcinoma (SCC, and its association with the clinicopathological characteristics of the tumor.   Materials and Methods:  Using an enzyme-linked immunosorbent assay (ELISA kit, we investigated the circulating levels of endostatin in the blood serum of 45 patients with oral SCC and 45 healthy controls.   Results: The mean level of serum endostatin in patients was significantly lower (68.8±85 ng/ml than in healthy controls (175.6±73 ng/ml (P

  11. Evaluation of automated serum des-gamma-carboxyprothrombin (DCP) assays for detecting hepatocellular carcinoma.

    Science.gov (United States)

    Choi, Jonghyeon; Park, Yongjung; Kim, Jeong-Ho; Kim, Hyon-Suk

    2011-12-01

    We evaluated two new autoanalyzers, μTAS and Lumipulse for des-γ-carboxyprothrombin (DCP) assay. Analytical performance was evaluated, and the upper reference limit of the 97.5th percentile for DCP was re-established using sera from 140 healthy individuals. DCP levels were determined by the two autoanalyzers and EIA in a total of 239 sera from HCC patients (n=120) and those without HCC (n=119). Total imprecision of the two automated assays was Lumipulse. There were proportional and constant biases between the results from the autoanalyzers and those from EIA. The two newly developed DCP assays showed high analytical performance, but re-establishment of reference limits would be necessary. The new analyzers could be useful for clinical laboratories because of convenience of operation and wide AMRs. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Titration of individual strains in trivalent live-attenuated influenza vaccine without neutralization.

    Science.gov (United States)

    Sirinonthanawech, Naraporn; Surichan, Somchaiya; Namsai, Aphinya; Puthavathana, Pilaipan; Auewarakul, Prasert; Kongchanagul, Alita

    2016-11-01

    Formulation and quality control of trivalent live-attenuated influenza vaccine requires titration of infectivity of individual strains in the trivalent mix. This is usually performed by selective neutralization of two of the three strains and titration of the un-neutralized strain in cell culture or embryonated eggs. This procedure requires standard sera with high neutralizing titer against each of the three strains. Obtaining standard sera, which can specifically neutralize only the corresponding strain of influenza viruses and is able to completely neutralize high concentration of virus in the vaccine samples, can be a problem for many vaccine manufacturers as vaccine stocks usually have very high viral titers and complete neutralization may not be obtained. Here an alternative approach for titration of individual strain in trivalent vaccine without the selective neutralization is presented. This was done by detecting individual strains with specific antibodies in an end-point titration of a trivalent vaccine in cell culture. Similar titers were observed in monovalent and trivalent vaccines for influenza A H3N2 and influenza B strains, whereas the influenza A H1N1 strain did not grow well in cell culture. Viral interference among the vaccine strains was not observed. Therefore, providing that vaccine strains grow well in cell culture, this assay can reliably determine the potency of individual strains in trivalent live-attenuated influenza vaccines. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A method of radiocompetitive assay of total thyroxine in the serum by means of enzymatic release of thyroxine from the transporting proteins

    International Nuclear Information System (INIS)

    Snarski, A.; Wyrwinski, J.

    1978-01-01

    Pepsin causes denaturation of the transporting proteins and liberates thyroxine which can be assayed by the radiocompetitive method. Change of the pH of the medium from acid to alkaline inactivates irreveribly pepsin. The enzymatic release of thyroxine is much simpler that the method of ethanol extraction and thermal denaturation of the transporting proteins applied up to now. The new technique of thyroxine release has been introduced for radiocompetitive determination of thyroxine using dextran coated charcoal for adsorption of the free hormone. A new method has been elaborated for preparation of working standards of thyroxine in a mixture of pepsin solution with hormone-free serum. The method is efficient and rapid. The normal range is from 50 to 130 nanomol/l. Over 7 000 determinations were done as yet in patients with suspected thyroid function disturbances. (author)

  14. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Science.gov (United States)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-01-01

    Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433

  15. Effective surveillance for early classical swine fever virus detection will utilize both virus and antibody detection capabilities.

    Science.gov (United States)

    Panyasing, Yaowalak; Kedkovid, Roongtham; Thanawongnuwech, Roongroje; Kittawornrat, Apisit; Ji, Ju; Giménez-Lirola, Luis; Zimmerman, Jeffrey

    2018-03-01

    Early recognition and rapid elimination of infected animals is key to controlling incursions of classical swine fever virus (CSFV). In this study, the diagnostic characteristics of 10 CSFV assays were evaluated using individual serum (n = 601) and/or oral fluid (n = 1417) samples collected from -14 to 28 days post inoculation (DPI). Serum samples were assayed by virus isolation (VI), 2 commercial antigen-capture enzyme-linked immunosorbent assays (ELISA), virus neutralization (VN), and 3 antibody ELISAs. Both serum and oral fluid samples were tested with 3 commercial real-time reverse transcription-polymerase chain reaction (rRT-PCR) assays. One or more serum samples was positive by VI from DPIs 3 to 21 and by antigen-capture ELISAs from DPIs 6 to 17. VN-positive serum samples were observed at DPIs ≥ 7 and by antibody ELISAs at DPIs ≥ 10. CSFV RNA was detected in serum samples from DPIs 2 to 28 and in oral fluid samples from DPIs 4 to 28. Significant differences in assay performance were detected, but most importantly, no single combination of sample and assay was able to dependably identify CSFV-inoculated pigs throughout the 4-week course of the study. The results show that effective surveillance for CSFV, especially low virulence strains, will require the use of PCR-based assays for the detection of early infections (<14 days) and antibody-based assays, thereafter. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. The detection of hemorrhagic proteins in snake venoms using monoclonal antibodies against Virginia opossum (Didelphis virginiana) serum.

    Science.gov (United States)

    Sánchez, E E; García, C; Pérez, J C; De La Zerda, S J

    1998-10-01

    Most snakes and a few warm-blooded animals have a resistance to snake venoms because of naturally occurring antihemorrhagins found in their sera. The antihemorrhagins in serum of Virginia opossum (Didelphis virginiana) neutralize hemorrhagic activity by binding to hemorrhagins in snake venoms. The binding characteristic of antihemorrhagins in D. virginiana serum was used to develop a five-step western blot. The detection of hemorrhagic proteins were measured indirectly with antihemorrhagins in Virginia opossum serum and with DV-2LD#2, a monoclonal antibody specific for Virginia opossum antihemorrhagins. Snake venoms were separated by native-PAGE, transferred to a Millipore Immobilon-P membrane and then incubated with crude Virginia opossum serum. The hemorrhagins in snake venom bind to antihemorrhagins in Virginia opossum serum which react with DV-2LD#2 a monoclonal antibody that is specific for Virginia opossum antihemorrhagins. DV-2LD#2 monoclonal antibody inhibits antihemorrhagic activity in Virginia opossum serum when mixed in equal amounts. The inhibition of antihemorrhagins by DV-2LD#2 monoclonal antibody suggests specificity. DV-2LD#2 monoclonal antibody does not recognize antihemorrhagins in gray woodrat (Neotoma micropus) serum. The five-step western blot reveals two well-defined bands which represent hemorrhagins found in Western diamondback rattlesnake (Crotalus atrox) venom. Venoms from 15 different snake species were examined to determine the usefulness of the five-step western blot. Other hemorrhagic venoms (Great Basin rattlesnake (C. viridis lutosus), Prairie rattlesnake (C. viridis viridis), Tancitaran dusky rattlesnake (C. pusillus), Northern Mojave rattlesnake (C. scutulatus scutulatus type B) and Northern Pacific rattlesnake (C. v. oreganus)) had one single band in the five-step western blot. DV-2LD#2 did not bind to the non-hemorrhagic venoms and reacted with 50% of the hemorrhagic venoms used in this study. The monoclonal antibody, CAH

  17. Clinical evaluation of the Byk LIA-mat CA125 II assay: discussion of a reference value.

    Science.gov (United States)

    Bonfrer, J M; Korse, C M; Verstraeten, R A; van Kamp, G J; Hart, G A; Kenemans, P

    1997-03-01

    The Byk LIA-mat CA125 II assay was compared with the Centocor IRMA CA125 II. Serum samples studied (n = 1012) were obtained from 652 apparently healthy females, 61 pregnant women, and 299 patients with benign and malignant gynecological tumors. The CA125 II assay value at the 95th percentile of the total healthy group was 29 kU/L for the LIA-mat and 32 kU/L for the Centocor assay. For the LIA-mat assay the 95th percentile was 31 kU/L (Centocor 36 kU/L) for the group 55 years of age. By using ROC curves we found the optimal pretreatment Byk LIA-mat CA125 II value differentiating between benign and malignant ovarian tumors to be 95 kU/L. Pretreatment CA125 values > 1000 kU/L were detected in serum samples of patients with advanced epithelial ovarian cancer.

  18. Neutralization of toxicological activities of medically-relevant Bothrops snake venoms and relevant toxins by two polyvalent bothropic antivenoms produced in Peru and Brazil.

    Science.gov (United States)

    Estevao-Costa, Maria I; Gontijo, Silea S; Correia, Barbara L; Yarleque, Armando; Vivas-Ruiz, Dan; Rodrigues, Edith; Chávez-Olortegui, Carlos; Oliveira, Luciana S; Sanchez, Eladio F

    2016-11-01

    Snakebite envenoming is a neglected public pathology, affecting especially rural communities or isolated areas of tropical and subtropical Latin American countries. The parenteral administration of antivenom is the mainstay and the only validated treatment of snake bite envenoming. Here, we assess the efficacy of polyspecific anti-Bothrops serum (α-BS) produced in the Instituto Nacional de Salud (INS, Peru) and at the Fundação Ezequiel Dias (FUNED, Brazil), to neutralize the main toxic activities induced by five medically-relevant venoms of: Bothrops atrox, B. barnetti, and B. pictus from Peru, and the Brazilian B. jararaca and B. leucurus, all of them inhabiting different geographical locations. Protein electrophoretic patterns of these venoms showed significant differences in composition, number and intensity of bands. Another goal was to evaluate the efficacy and safety of lyophilized α-BS developed at INS to neutralize the detrimental effects of these venoms using in vivo and in vitro assays. The availability of lyophilized α-BS has relevant significance in its distribution to distant rural communities where the access to antivenom in health facilities is more difficult. Despite the fact that different antigen mixtures were used for immunization during antivenom production, our data showed high toxin-neutralizing activity of α-BS raised against Bothrops venoms. Moreover, the antivenom cross-reacted even against venoms not included in the immunization mixture. Furthermore, we have evaluated the efficacy of both α-BS to neutralize key toxic compounds belonging to the predominant protein families of Bothrops snakes. Most significantly, both α-BS cross-specifically neutralized the main toxicological activities e.g. lethality and hemorrhage induced by these venoms. Thus, our data indicate that both α-BS are equally effective to treat snake bite victims inflicted by Bothrops snakes particularly B. atrox, responsible for the largest numbers of human

  19. The evaluation of a user-friendly lateral flow assay for the serodiagnosis of human brucellosis in Kazakhstan.

    Science.gov (United States)

    Mizanbayeva, Sulushash; Smits, Henk L; Zhalilova, Katya; Abdoel, Theresia H; Kozakov, Stanislaw; Ospanov, Kenes S; Elzer, Philip H; Douglas, James T

    2009-09-01

    Serum samples from all patients with culture-confirmed brucellosis including those with chronic disease from Kazakhstan tested positive in the serum agglutination test for titers > or = 1:25 and reacted in the Brucella immunoglobulin M/immunoglobulin G lateral flow assay (LFA) confirming the high sensitivity of these assays. The strong reactivity in the LFA observed for the majority (92.1%) of the samples from the patients with culture-confirmed brucellosis together with the user-friendliness of the assay procedure makes the LFA ideal for the confirmation of brucellosis in endemic areas in Kazakhstan. The Rose Bengal test lacked sensitivity in particular for patients with chronic brucellosis therefore limiting its value as a quick screening assay. The study emphasizes the importance of the LFA as a useful, rapid, and easy-to-perform tool in the diagnostic testing of brucellosis.

  20. Recombinant Helicobacter bilis Protein P167 for Mouse Serodiagnosis in a Multiplex Microbead Assay

    OpenAIRE

    Feng, Sunlian; Kendall, Lon V.; Hodzic, Emir; Wong, Scott; Lorenzana, Edward; Freet, Kimberly; Ku, Karin S.; Luciw, Paul A.; Barthold, Stephen W.; Khan, Imran H.

    2004-01-01

    Infection of mice with Helicobacter bilis is widespread in research and commercial mouse colonies. Therefore, sensitive, specific, and high-throughput assays are needed for rapid and accurate testing of mice in large numbers. This report describes a novel multiplex assay, based on fluorescent microbeads, for serodetection of H. bilis infection. The assay requires only a few microliters of serum to perform and is amenable to a high-throughput format. Individual microbead sets were conjugated t...

  1. Reliability of soluble IL-2 receptor measurements obtained with enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Akiyama, Mitoshi; Takaishi, Masatoshi; Murakami, Yoshie; Ueda, Ryuzo; Yamakido, Michio; Tsubokura, Tokuo.

    1989-09-01

    Using an enzyme-linked immunosorbent assay (ELISA), human soluble interleukin-2 receptors (IL-2R) were measured in the serum of patients with various autoimmune system diseases. To study the sensitivity and specificity of the assay, soluble IL-2Rs were measured in the culture supernatants and in the cell extracts of peripheral blood mononuclear cells activated with phytohemagglutinin (PHA), purified protein derivative of tuberculin, and allogeneic lymphocytes, as well as in the serum of patients with various collagen diseases. The results correlated well with reports from other laboratories. For example, when stimulated by PHA, the greatest amount of soluble IL-2Rs was produced at the fastest rate. In addition, soluble IL-2R levels in the serum of collagen disease patients were significantly higher than those in healthy persons, who themselves exhibited low levels of detectable soluble IL-2Rs. It is hoped that reliable ELISA measurements of soluble IL-2Rs in the serum of atomic bomb survivors will assist in the interpretation of data collected during the work described in RP 2-87, a study of autoimmunity and autoimmune diseases in the Adult Health Study. (author)

  2. Inter-laboratory and inter-assay comparison on two real-time PCR techniques for quantification of PCV2 nucleic acid extracted from field samples

    DEFF Research Database (Denmark)

    Hjulsager, Charlotte Kristiane; Grau-Roma, L.; Sibila, M.

    2009-01-01

    Several real-time PCR assays for quantification of PCV2 DNA (qPCR) have been described in the literature. and different in-house assays are being used by laboratories around the world. A general threshold of it copies of PCV2 per millilitre serum for postweaning multisystemic wasting syndrome (PMWS......) diagnosis has been suggested. However, neither inter-laboratory nor inter-assay comparisons have been published so far. In the present study two different qPCR probe assays Used routinely in two laboratories were compared on DNA extracted From serum, nasal and rectal swabs. Results showed a significant...

  3. Diagnostic relevance of radioiron-absorption-measurements and immunoradiometric serum-ferritin-assay in the evaluation of iron stores

    International Nuclear Information System (INIS)

    Heinrich, H.C.

    1978-01-01

    Negative iron balance and enhanced iron demand respectively causes deficient iron stores (prelatent iron deficiency) with increased iron absorption, later on decrease of serum iron and increase of transferrin (latent Fe deficiency) and at least iron deficient anemia (manifest iron deficiency). In prelatend iron deficiency diagnostic 59 Fe 2+ absorption is increased and the RES cells do not show storage iron cytochemically. In latent iron deficiency in addition serum iron, transferrin iron saturation and serum ferritin is decreased and hypochromic mikrocytic anemia completes the signs of manifest iron deficiency. Besides rare cases of primary hemochromatosis and marked hyperdasia of ineffective erythropoiesis in homocygotic beta-thalassemia, hereditary non-spherocytic hemolytic anemia caused by pyruvate kinase deficiency and some sideroblastic anemias increased 59 Fe 2+ absorption is a reliable measure of exhausted iron stores. In these exceptional cases differential diagnosis between sideroachrestic and siderosensitive iron deficiency anemia can be made by measurement of serum iron and serum ferritin respectively. The etiology of iron deficiency is to be cleared by measurement of 59 Fe absorption from 59 Fe 2+ and 59 Fe-marked meat with consecutive estimation of whole body 59 Fe elimination. Shortly after completion or during oral iron therapy serum ferritin concentration is not suitable to evaluate the content of iron stores. (orig.) [de

  4. Contents of trace elements in blood of healthy old people assayed by ICP-MS

    International Nuclear Information System (INIS)

    Wen Xinyu; Tong Hongli; Wang Ling; Zhou Heping; Tian Yaping

    2008-01-01

    To investigate the levels of 11 trace elements in serum of healthy old people to provide scientific basis for prevention and treatment of geriatric diseases, the serum were separated from blood samples according to standard procedure. The serum samples were underwent digestion, elimination of nitric acid, volume fixation and then assayed by inductively coupled plasma mass spectrometry. The results showed that the contents of Al in elderly people's serum is higher than those in young people (P<0.01), while the contents of V, Cr, Cu and Se in elderly people's serum were lower than those in young people (P<0.05). There were no significant differences in other trace elements between two groups. The contents of some trace elements in elderly people's serum changed significantly. (authors)

  5. Serum adiponectin levels in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Fayyaz, I.; Shah, S.I.; Ghani, M.

    2009-01-01

    Adiponectin is an adipocytokine secreted from white adipose tissue. Serum level of adiponectin has been shown to be reduced in several disease states like obesity and diabetes. Hypoadiponectinemia has also been included in the list of newer risk factors for Coronary Artery Disease (CAD). In this analytical cross-sectional study serum adiponectin level was measured by Enzyme Linked Immunosorbant Assay (ELISA) in 60 cases of coronary artery disease (CAD) (both sexes, aged 40-60 yrs) and 60 healthy controls. Low levels of adiponectin were seen in CAD patients as well as controls. These levels were lower as compared to western standards. Our study conforms to the previous observation of lower serum adiponectin levels in South Asians compared to the western standards. Serum adiponectin level should be considered in the laboratory work-up of CAD patients. (author)

  6. Correlation of Serum Cystatin C with Glomerular Filtration Rate in Patients Receiving Platinum-Based Chemotherapy

    Directory of Open Access Journals (Sweden)

    Ernesta Cavalcanti

    2016-01-01

    Full Text Available Objectives. Serum cystatin C seems to be an accurate marker of glomerular filtration rate (GFR compared to serum creatinine. The aim of this work was to explore the possibility of using serum cystatin C instead of serum creatinine to early predict renal failure in cancer patients who received platinum based chemotherapy. Design and Methods. Serum creatinine, serum cystatin C concentrations, and GFR were determined simultaneously in 52 cancer patients received carboplatin-based or cisplatin-based chemotherapy. Serum creatinine was assayed on Cobas C6000-Roche, serum cystatin C assay was performed on AIA 360-Tosoh, and GFR was determined in all patients, before the first cycle of chemotherapy and before the subsequent administrations. Results. In the overall series, for the prediction of a fall of GFR < 80 mL/min/1.73 m2, the AUC of the ROC curve for cystatin C was 0,667 and the best threshold was 1.135 mg/L (sensitivity 90.5%, specificity 61.1%. For a GFR fall < 60 mL/min/1.73 m2, the AUC of ROC curve for cystatin C was 74.3% and the best threshold was 1.415 mg/L (sensitivity 66.7%, specificity 73.2%. Conclusions. Baseline cystatin C values were not able to predict renal failure during subsequent treatment. In conclusion, serum cystatin C is not a reliable early marker to efficiently predict renal failure in patients receiving chemotherapy.

  7. Sex differences in the aging pattern of renin-angiotensin system serum peptidases.

    Science.gov (United States)

    Fernández-Atucha, A; Izagirre, A; Fraile-Bermúdez, A B; Kortajarena, M; Larrinaga, G; Martinez-Lage, P; Echevarría, E; Gil, J

    2017-01-01

    Serum peptidases, such as angiotensin-converting enzyme (ACE), angiotensin-converting enzyme-2 (ACE2), neutral endopeptidase (NEP), aminopeptidase N (APN), and aminopeptidase A (APA), are important elements of the renin-angiotensin system (RAS). Dysregulation of these enzymes has been associated with hypertension and cardiovascular risk. In the present study, serum activities of RAS peptidases were analyzed to evaluate the existence of sexual differences, with a possible different pattern in pre- and post-andropausal/post-menopausal participants. One hundred and eighteen healthy men and women between 41 and 70 years of age (58 women and 60 men) were recruited to participate in the study. Serum RAS-regulating enzymes were measured by spectrofluorimetry. Enzymatic activity was recorded as units of enzyme per milliliter of serum (U/mL). Significantly lower serum APA activity was observed in men with respect to women; no sex differences were detected for ACE, ACE2, NEP, or APN. Significantly lower APA and ACE serum activity were observed in older men compared to older women. In contrast, younger (menopausia, on the critical serum enzymatic activities of the RAS, which could correlate with sexual differences in cardiovascular risk.

  8. Whole blood microculture assay of human lymphocyte function.

    Science.gov (United States)

    Pauly, J L; Han, T

    1976-11-01

    A whole blood microculture assay is described for measuring lymphocyte reactivity to mitogenic and antigenic stimulants. This assay employs heparinized whole blood, serum-free culture medium, microtiter plates, and a Multiple Automated Sample Harvester (MASH). When this assay is compared to other leukocyte assays, its major advantages include (1) the utilization of fewer lymphocytes per microculture, thuus reducing the amount of blood required per test while increasing the number of test agents and replicate cultures which can be employed in any given experiment; (2) the conservation of mitogens, antigens, drugs, enzymes, hormones, lymphokines, and other test agents, some of which are either expensive of difficult to prepare in large quantities; (3) the elimination of lymphocyte isolation and purification procedures which may disrupt the relative proportion of T cells, B cells and antigen-processing cells; and (4) the application of an automated harvester which simplifies and expedites procedures required for processing cells for liquid scintillation counting.

  9. haematological parameters and serum biochemical indices of pre

    African Journals Online (AJOL)

    mrmrsolayiwola

    2012-05-01

    May 1, 2012 ... pubertal male rabbits fed with graded level of blood- ... The effects of feeding graded levels of blood wild sunflower forage meal ... and serum biochemical parameters in rabbit were studied. ... (Cheeke et al., 1986), high in protein, low in cholesterol ..... assay of nutritional anaemia (dietary deficiency of iron,.

  10. A ring test of in vitro neutral detergent fiber digestibility: Analytical variability and sample ranking

    Science.gov (United States)

    In vitro neutral detergent fiber (NDF) digestibility (NDFD) is an empirical measurement used to describe fermentability of NDF by rumen microbes. Variability is inherent in assays and affects the precision that can be expected for replicated samples. The study objective was to evaluate variability w...

  11. Diagnosis of Fasciola gigantica infection in cattle using capture-ELISA assay for detecting antigen in faeces

    Directory of Open Access Journals (Sweden)

    Sarwitri Endah Estuningsih

    2006-10-01

    Full Text Available Capture-ELISA assay is a diagnosis for antigen detection in the serum or faeces using polyclonal or monoclonal antibodies. The purpose of this study was to determine the sensitivity and specificity of capture-ELISA assay using polyclonal antibody for diagnosing Fasciola gigantica infection in cattle by detecting antigen in the faeces. In this study, faecal samples and livers were collected from 141 cattle slaughtered in the abattoir in Jakarta. From each animal, liver was processed for liver flukes count and the corresponding faecal sample was analysed for coproantigen. The result of capture-ELISA assay for antigen detection showed that from 85 cattle infected with Fasciola gigantica, 83 had OD > 0.52 (range from 0.52-1.39 and 2 cattle had OD < 0.52 (range from 0.17-0.51. The sensitivity and specificity of the assay were 97.6% and 92.8% respectively. The assay also able to detect 50 ng/ml of antigen in faecal supernatant. It suggests that this assay will have the advantage over the other methods on its ability to detect the active infection. Collection of faeces, rather than serum, will allow a more cost-effective and adaptable method.

  12. Diagnosis of hepatocellular carcinoma by serial determination of serum alpha-fetoprotein concentration

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, Y; Namba, T; Tanaka, Y; Taketa, K; Ohta, Y [Okayama Univ. (Japan). School of Medicine

    1976-06-01

    This communication describes the clinical significance of serum ..cap alpha..-fetoprotein (S-AFP) determined by radioimmunoassay (RIA) in the diagnosis of hepatocellular carcinoma (HCC). The sensitivity of the AFP assay with the ..cap alpha..-Feto-125 kit produced by the Dainabot RI laboratories was over 2.5 ng/ml. Reproducibility of the kit was satisfactory; coefficient of variation was 6-10% within assays and 13% between assays. The mean and standard deviation of S-AFP in the sera of 30 healthy controls was 5.6+-2.6 ng/ml. When serum with a high level of S-AFP (2.9x10/sup 5/ ng/ml) was diluted with normal horse serum, the actual concentrations of AFP in the diluted serum were consistent with those determined. Thus, normal horse serum was employed to dilute the sera with high levels of AFP. Levels of S-AFP were over 2000 ng/ml in 75.5% of 49 cases with HCC, in 0.64% of 157 patients with hepatitis and cirrhosis of the liver, and in 3.8% of 52 cases of metastatic gastric cancer to the liver. In 20 patients with HCC, levels of S-AFP ranged widely from 7.5 to 9.5x10/sup 5/ ng/ml. In serial determinations of S-AFP in the clinical courses of patients such as those with S-AFP over 2000 ng/ml, the continuous increase of AFP was strongly suggestive of the presence of HCC. In 4 of 20 cases of HCC, the S-AFP levels remained under 300 ng/ml. Histological examination of these 4 cases of HCC showed Classes I and II, but no III in Edmondson's classification. Other cases of HCC with S-AFP levels over 300 ng/ml showed Edmondson's Classes II and III.

  13. A microfluorometric assay for immunoglobulin class and subclass levels in murine serum

    NARCIS (Netherlands)

    Haaijman, J.J.; Brinkhof, J.

    1977-01-01

    The IgG fractions of rabbit antisera specific for the Fc part of mouse IgA, IgM, and the four subclasses of IgG (1, 2a, 2b, and 3) were coupled covalently to Sepharose beads by the cyanogen bromide method. The beads were then incubated with different dilutions of mouse serum. The mouse

  14. Serotype determination of Salmonella by xTAG assay.

    Science.gov (United States)

    Zheng, Zhibei; Zheng, Wei; Wang, Haoqiu; Pan, Jincao; Pu, Xiaoying

    2017-10-01

    Currently, no protocols or commercial kits are available to determine the serotypes of Salmonella by using Luminex MAGPIX®. In this study, an xTAG assay for serotype determination of Salmonella suitable for Luminex MAGPIX® is described and 228 Salmonella isolates were serotype determined by this xTAG assay. The xTAG assay consists of two steps: 1) Multiplex PCR to amplify simultaneously O, H and Vi antigen genes of Salmonella, and 2) Magplex-TAG™ microsphere hybridization to identify accurately the specific PCR products of different antigens. Compared with the serotyping results of traditional serum agglutination test, the sensitivity and specificity of the xTAG assay were 95.1% and 100%, respectively. The agreement rate of these two assays was 95.2%. Compared with Luminex xMAP® Salmonella Serotyping Assay (SSA) kit, the advantages of this xTAG assay are: First, the magnetic beads make it applicable to both the Luminex®100/200™ and MAGPIX® systems. Second, only primers rather than both primers and probes are needed in the xTAG assay, and the process of coupling antigen-specific oligonucleotide probes to beads is circumvented, which make the xTAG assay convenient to be utilized by other laboratories. The xTAG assay may serve as a rapid alternative or complementary method for traditional Salmonella serotyping tests, especially for laboratories that utilize the MAGPIX® systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Serum hyaluronic acid levels during pregnancy and labor.

    Science.gov (United States)

    Kobayashi, H; Sun, G W; Tanaka, Y; Kondo, T; Terao, T

    1999-04-01

    To study the changes in concentrations of serum hyaluronic acid in uncomplicated human pregnancies. We determined the concentrations of serum hyaluronic acid, using a specific enzyme-linked immunosorbent assay, in 70 nonpregnant women, 250 women during their pregnancies, and 68 women at the time of parturition. Results were analyzed for statistical significance with Scheffé test for multiple comparisons. During pregnancy, mean (+/- standard deviation) serum hyaluronic acid levels were 11.4 +/- 4.5, 13.6 +/- 2.8, 20.6 +/- 1.5, and 46.9 +/- 7.9 ng/mL at 5-14 (n = 47), 15-26 (n = 46), 27-37 (n = 58), and 38-40 (n = 99) weeks' gestation, respectively. Pregnant women in labor (n = 68) had significantly higher levels (100.4 +/- 11.3 ng/mL) than did women at term but not in labor (P hyaluronic acid concentrations increase as pregnancy progresses and serum levels increase significantly at term. Hyaluronic acid may be associated with cervical ripening during parturition.

  16. The evaluation of a user-friendly lateral flow assay for the serodiagnosis of human brucellosis in Kazakhstan

    NARCIS (Netherlands)

    Mizanbayeva, Sulushash; Smits, Henk L.; Zhalilova, Katya; Abdoel, Theresia H.; Kozakov, Stanislaw; Ospanov, Kenes S.; Elzer, Philip H.; Douglas, James T.

    2009-01-01

    Serum samples from all patients with culture-confirmed brucellosis including those with chronic disease from Kazakhstan tested positive in the serum agglutination test for titers > or = 1:25 and reacted in the Brucella immunoglobulin M/immunoglobulin G lateral flow assay (LFA) confirming the high

  17. Population-based Tay-Sachs screening among Ashkenazi Jewish young adults in the 21st century: Hexosaminidase A enzyme assay is essential for accurate testing.

    Science.gov (United States)

    Schneider, Adele; Nakagawa, Sachiko; Keep, Rosanne; Dorsainville, Darnelle; Charrow, Joel; Aleck, Kirk; Hoffman, Jodi; Minkoff, Sherman; Finegold, David; Sun, Wei; Spencer, Andrew; Lebow, Johannah; Zhan, Jie; Apfelroth, Stephen; Schreiber-Agus, Nicole; Gross, Susan

    2009-11-01

    Tay-Sachs disease (TSD) carrier screening, initiated in the 1970s, has reduced the birth-rate of Ashkenazi Jews with TSD worldwide by 90%. Recently, several nationwide programs have been established that provide carrier screening for the updated panel of Jewish genetic diseases on college campuses and in Jewish community settings. The goals of this study were to determine the performance characteristics of clinical TSD testing in college- and community-based screening programs and to determine if molecular testing alone is adequate in those settings. Clinical data for TSD testing were retrospectively anonymized and subsequently analyzed for 1,036 individuals who participated in these programs. The performance characteristics of the serum and the platelet Hexosaminidase assays were compared, and also correlated with the results of targeted DNA analysis. The serum assay identified 29 carriers and the platelet assay identified 35 carriers for carrier rates of 1/36 and 1/29, respectively. One hundred sixty-nine samples (16.3%) were inconclusive by serum assay in marked contrast to four inconclusive samples (0.4%) by the platelet assay. Molecular analysis alone would have missed four of the 35 carriers detected by the platelet assay, yielding a false negative rate of 11.4% with a sensitivity of 88.6%. Based on the results of this study, platelet assay was superior to serum with a minimal inconclusive rate. Due to changing demographics of the Ashkenazi Jewish population, molecular testing alone in the setting of broad-based population screening programs is not sufficient, and biochemical analysis should be the assay of choice. Copyright 2009 Wiley-Liss, Inc.

  18. ASTRO Research Fellow Presentation - A comparison of the comet assay and pulsed-field gel electrophoresis as a predictive assay for radiosensitivity in human fibroblasts

    International Nuclear Information System (INIS)

    Sarkaria, Jann N.; Eady, John J.; Peacock, John H.; Steel, G. Gordon

    1996-01-01

    Purpose/Objective: To determine whether neutral lysis single-cell gel electrophoresis (comet assay) or pulsed-field gel electrophoresis (PFGE) can be used as a predictive assay for tissue response to radiotherapy as an alternative to clonogenic survival measurements. Materials and Methods: The comet assay has been widely used to measure DNA double strand breaks (dsb) in individual cells, and it has been suggested that it could be used as an alternative to clonogenic assays to measure radiosensitivity. Previous studies in this lab have demonstrated the ability of pulsed-field gel electrophoresis, which also measures DNA dsb, to accurately predict the radiosensitivity of a panel of fibroblasts based on determination of residual DNA dsb. As part of an ongoing study examining the relationship between fibroblast radiosensitivity and normal-tissue radiation reactions, we have compared the sensitivity and accuracy of the comet assay and PFGE on a different panel of non-transformed fibroblasts derived from breast cancer patients who developed severe radiation late effects and from case-matched controls. For the measurement of initial damage, cells were suspended in PBS and irradiated on ice for the comet assay and irradiated in agarose plugs on ice for pFGE. Residual damage was measured following irradiation of confluent cultures at 37 degree sign C and subsequent incubation for four hours prior to preparation of agarose slides and plugs. All irradiations were performed with a 59 TBq 60 Co source at a dose rate of 1.7 Gy/min. Electrophoresis was performed following neutral pH cell lysis. Comet images were captured and analyzed using Optimas software with DNA damage quantitated by the comet moment. PFGE gels were analyzed using a phosphor-image analysis system and damage was quantitated based on the percent of activity released from the well. Results: The comet assay was able to detect initial DNA damage at a threshold of 5 Gy and exhibited a linear dose

  19. Comparison of 2 molecular assays and a serologic test in diagnosing Mycoplasma pneumoniae infection in paediatrics patients.

    Science.gov (United States)

    Blanco, Silvia; Fuenzalida, Loreto; Bas, Albert; Prat, Cristina; Ramírez, Aida; Matas, Lurdes; Rodrigo, Carlos; Ausina, Vicente

    2011-12-01

    Two commercial polymerase chain reaction (PCR) assays (a real-time PCR [Cepheid] and an oligochromatographic test [Speed-oligo]) and 1 serology test (Serodia-Myco II) for detecting Mycoplasma pneumoniae in nasopharyngeal aspirates and serum samples were studied. Among the 145 samples, 32 serum pairs were serologically positive for M. pneumoniae. Of these, in 30 nasopharyngeal aspirates, M. pneumoniae was detected using the real-time PCR assay and 25 using Speed-oligo, corresponding to a sensitivity of 93.7% and 78.1%, respectively. Among the 94 samples with negative serology, we only obtained 1 positive result by real-time PCR assay. In the group of samples from healthy children, no positive results were obtained. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Antiradiation Antitoxin IgG : Immunological neutralization of Radiation Toxins at Acute Radiation Syndromes.

    Science.gov (United States)

    Popov, Dmitri; Maliev, Slava

    radiation toxins to induce hyperimmune serum: Group A -Toxoid form of CV ARS toxins ( SRD-1); Group B-Toxoid form of CR ARS (SRD-2)toxins ; Group C -Toxoid form of GI ARS (SRD-3); Group D -Toxoid form of HP ARS (SRD-4). After the hyperimmune serum was pooled from several animals, purified, and concentrated, the IgG fraction was separated. Enzyme-linked immunosorbent assays of the hyper-immune serum had revealed high titers of IgG with specific binding to radi-ation toxins. The antiradiation IgG preparation was injected into laboratory animals one hour before and three hours after irradiation, and was evaluated for its ability to protect inoculated animals against the development of acute radiation syndromes. Results: Animals that were inoculated with specific antiradiation antibodies before and after receiving lethal irradiation at LD 100/30 exhibited 60-75% survival rate within 30 days. Also, these animals inoculated with the Antiradiation Antitoxin had exhibited markedly reduced clinical symptoms of the ARS, even those ones that did not survive irradiation. Discussion: The results of our experiments have demonstrated that the rabbit hyperimmune IgG preparations directed against SRD toxins provide a significant protection against high doses of radiation. In comparison, the mortality rate of irradiated control animals was 100% in the same time period. The mortality rates of animals treated by the hyperimmune IgG antidote have varied in the different groups of ani-mals and different forms of the ARS. However, significant radioprotection was observed in each group treated with the IgGs. The specific antiradiation antidote IGg isolated from hyperim-mune serum of immunized horses is under study. The specific antiradiation antidote contains antibodies to neurotoxins -SAAN IgG includes 50% IgG to Cv ARS, 25% IgG to Cr ARS and 25 % IgG to Gi ARS. The other type of the Specific antiradiation antidote containes antibodies to hematotoxins -SAAH IgG -100%. A combined variant is under

  1. Metal-amplified Density Assays, (MADAs), including a Density-Linked Immunosorbent Assay (DeLISA).

    Science.gov (United States)

    Subramaniam, Anand Bala; Gonidec, Mathieu; Shapiro, Nathan D; Kresse, Kayleigh M; Whitesides, George M

    2015-02-21

    This paper reports the development of Metal-amplified Density Assays, or MADAs - a method of conducting quantitative or multiplexed assays, including immunoassays, by using Magnetic Levitation (MagLev) to measure metal-amplified changes in the density of beads labeled with biomolecules. The binding of target analytes (i.e. proteins, antibodies, antigens) to complementary ligands immobilized on the surface of the beads, followed by a chemical amplification of the binding in a form that results in a change in the density of the beads (achieved by using gold nanoparticle-labeled biomolecules, and electroless deposition of gold or silver), translates analyte binding events into changes in density measureable using MagLev. A minimal model based on diffusion-limited growth of hemispherical nuclei on a surface reproduces the dynamics of the assay. A MADA - when performed with antigens and antibodies - is called a Density-Linked Immunosorbent Assay, or DeLISA. Two immunoassays provided a proof of principle: a competitive quantification of the concentration of neomycin in whole milk, and a multiplexed detection of antibodies against Hepatitis C virus NS3 protein and syphilis T. pallidum p47 protein in serum. MADAs, including DeLISAs, require, besides the requisite biomolecules and amplification reagents, minimal specialized equipment (two permanent magnets, a ruler or a capillary with calibrated length markings) and no electrical power to obtain a quantitative readout of analyte concentration. With further development, the method may be useful in resource-limited or point-of-care settings.

  2. Association of thyroid function with human serum ghrelin and leptin levels

    International Nuclear Information System (INIS)

    Wang Jinping; Xu Hao; Wu Qiulian

    2008-01-01

    Objective: To investigate the effect of different status of thyroid function (hypothyroidism and hyperthyroidism as well as euthyroid status) on serum ghrelin and leptin levels. Methods: The levels of serum ghrelin and leptin were determined by radio immunoassay in 46 untreated subjects with hyperthyroidism, 15 hyperthyroid patients achieved a euthyroid status after radioiodine 131 I therapy, 21 cases of hypothyroidism and 18 cases of normal controls, respectively. Meanwhile, the serum levels of free triiodothyronine (FT 3 ), free thyroxine (FT 4 ) and thyroid-stimulating hormone (TSH) were measured by chemiluminescence immune assay. Results: (1) The levels of serum ghrelin in untreated hyperthyroidism were significantly lower than those in hyperthyroid patients achieved a euthyroid status (t=3.21, P 3 (r=-0.29, P 4 (r=-0.26, P< 0.05), positively correlated with serum TSH (r=0.36, P<0.05); serum leptin levels did not correlate with thyroid hormone. Conclusion: The levels of serum ghrelin were differently under different thyroid functional status and correlated with thyroid hormone, while serum leptin were not. (authors)

  3. A sensitive competitive binding assay for exogenous and endogenous heparins

    International Nuclear Information System (INIS)

    Dawes, J.; Pepper, D.S.

    1982-01-01

    A new type of assay for heparins has been devised, in which the test material competes with 125 I-labelled heparin for binding to protamine-Sepharose. The assay is very sensitive and will measure heparin concentrations down to 10 ng ml-1. It responds to both the degree of sulphation and the molecular weight of acidic polysaccharides, but is independent of their biological activities. It can be used to quantitate heparins in biological fluids after pretreatment of the samples with protease. In this way endogenous heparins were measured in normal human serum, plasma and urine. The assay is extremely versatile and has great potential for the investigation of endogenous and exogenous heparins

  4. Serum components and clinical efficacies of autologous serum eye drops in dry eye patients with active and inactive Sjogren syndrome.

    Science.gov (United States)

    Ma, I-Hsin; Chen, Lily Wei; Tu, Wen-Hui; Lu, Chia-Ju; Huang, Chien-Jung; Chen, Wei-Li

    2017-01-01

    Autologous serum eye drops are considered safe and efficient for the treatment of various ocular surface disorders, including dry eye diseases (DED) caused by the primary and secondary Sjogren syndrome (SS). However, the serum components in patients of SS may be different from those of normal patients and can thus lead to unpredictable therapeutic effects. This study divided the SS patients into active and inactive types based on the erythrocyte sedimentation rate and the presence or absence of active rheumatoid arthritis. We compared the serum components of these two groups with standard and multiplex enzyme linked immunosorbent assay arrays and predicted the therapeutic effects of topical autologous serum for the treatment of DED with ocular surface disease index (OSDI) and Oxford Schema scale (OSS). Hyaluronic acid and transforming growth factor b1 levels were significantly higher in the active SS group compared to the inactive SS group ( P Sjogren dry eye patients into active and inactive groups may appear as a reasonable method to predict the quality of autologous serum eye drops, but there seems to be no significant predictability to the therapeutic effects.

  5. Direct radioimmunoassay of serum progesterone using heterologous bridge tracer and antibody

    International Nuclear Information System (INIS)

    Kothari, K.; Pillai, M.R.A.

    1998-01-01

    The standardisation of a direct radioimmunoassay for progesterone using an 125 I labeled progesterone prepared by iodinating the tyrosine methyl ester (TME) conjugated to a progesterone hemiphthalate derivative and an antibody prepared using a progesterone linked to bovine serum albumin through 11α hemisuccinate derivative is described. The hemiphthalate derivative of progesterone was prepared by reacting 11α-hydroxy progesterone with phthalic anhydride which was then conjugated to TME by using isobutyl chloroformate. The conjugate was iodinated with 125 I using chloramine-T as oxidising agent and purified by thin layer chromatography. Radiochemical purity of the tracer was >95% in all batches. The tracer gave 70-75% binding with excess antibody. Assays were optimised with 8-anilino-1-naphthalene sulphonic acid (ANS) and sodium salicylate as blocking agents to release the progesterone from binding proteins. The assays optimised with sodium salicylate as blocking agent has a sensitivity of 0.25 ng/ml and a working range of 0.25-50 ng/ml, whereas the assay with ANS has a sensitivity of 0.75 ng/ml and a working range of 0.75-100 ng/ml. Serum samples were analysed and compared with the values obtained with a homologous bridge assay. (author)

  6. Two new automated, compared with two enzyme-linked immunosorbent, antimüllerian hormone assays.

    Science.gov (United States)

    Nelson, Scott M; Pastuszek, Ewa; Kloss, Grzegorz; Malinowska, Iwona; Liss, Joanna; Lukaszuk, Aron; Plociennik, Lukasz; Lukaszuk, Krzysztof

    2015-10-01

    To compare new automated antimüllerian hormone (AMH) assay performance characteristics from the new automated Elecsys AMH (Roche; Elecsys) and Access AMH (Beckman Coulter; Access) assays with the existing AMH Gen II ELISA (enzyme-linked immunosorbent assay; Gen II; Beckman Coulter) and AMH ELISA (Ansh Labs) assays. Prospective assay evaluation. University-affiliated clinical chemistry laboratory. Patients referred for serum AMH measurement (n = 83) before start of in vitro fertilization cycle between September 2014 and October 2014. None. Serum AMH concentration. Intra-assay coefficients of variation were low; Ansh ≤ 9.0%; Gen II ≤ 5.8%; Access ≤ 10.7%; and Elecsys ≤ 2.8%. The Passing-Bablok regression equations (pmol/L) were y (Access) = 0.128 + (0.781 × Gen II); and y (Access) = 0.302 + (0.742 x Ansh). For y (Elecys) = 0.087 + (0.729 x Gen II) and y (Elecys) = 0.253 + (0.688 x Ansh Labs). For y (Elecys) = 0.943 - (0.037 × Access). For all the assays, AMH exhibited a moderate positive correlation with AFC (r = 0.62-0.64); number of cumulus oocyte complexes (r = 0.60-0.64); and metaphase II oocytes (r = 0.48-0.50). Accuracy of pregnancy prediction, as determined by area under the receiver operating characteristic curve, was uniformly low for all assays (0.62-0.63). The novel automated assays exhibit strong concordance in calibration, but derived values are substantially lower than those obtained from pre-existing assays, with assay-specific interpretation required for routine clinical use. These results highlight the need for an international standard of measurement of AMH. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Comparison of miRNA quantitation by Nanostring in serum and plasma samples.

    Directory of Open Access Journals (Sweden)

    Catherine Foye

    Full Text Available Circulating microRNAs that are associated with specific diseases have garnered much attention for use in diagnostic assays. However, detection of disease-associated miRNA can be affected by several factors such as release of contaminating cellular miRNA during sample collection, variations due to amplification of transcript for detection, or controls used for normalization for accurate quantitation. We analyzed circulating miRNA in serum and plasma samples obtained concurrently from 28 patients, using a Nanostring quantitative assay platform. Total RNA concentration ranged from 32-125 μg/ml from serum and 30-220 μg/ml from plasma. Of 798 miRNAs, 371 miRNAs were not detected in either serum or plasma samples. 427 were detected in either serum or plasma but not both, whereas 151 miRNA were detected in both serum and plasma samples. The diversity of miRNA detected was greater in plasma than in serum samples. In serum samples, the number of detected miRNA ranged from 3 to 82 with a median of 17, whereas in plasma samples, the number of miRNA detected ranged from 25 to 221 with a median of 91. Several miRNA such as miR451a, miR 16-5p, miR-223-3p, and mir25-3p were highly abundant and differentially expressed between serum and plasma. The detection of endogenous and exogenous control miRNAs varied in serum and plasma, with higher levels observed in plasma. Gene expression stability identified candidate invariant microRNA that were highly stable across all samples, and could be used for normalization. In conclusion, there are significant differences in both the number of miRNA detected and the amount of miRNA detected between serum and plasma. Normalization using miRNA with constant expression is essential to minimize the impact of technical variations. Given the challenges involved, ideal candidates for blood based biomarkers would be those that are indifferent to type of body fluid, are detectable and can be reliably quantitated.

  8. Therapeutic drug monitoring of caffeine in preterm infants: Could saliva be an alternative to serum?

    Science.gov (United States)

    Chaabane, Amel; Chioukh, Fatma Z; Chadli, Zohra; Ben Fredj, Nadia; Ben Ameur, Karim; Ben Hmida, Hayet; Boughattas, Naceur A; Monastiri, Kamel; Aouam, Karim

    2017-12-01

    Evaluate whether saliva could be a useful alternative to serum for routine therapeutic drug monitoring of caffeine in preterm infants using the enzyme multiplied immunoassay technique (EMIT) assay. We conducted a prospective study including preterm infants (less than 34 weeks' amenorrhea) admitted to the intensive care and neonatal medicine department. All infants received 5, 10, 15, 20 and 25mg/kg/day of citrate caffeine intravenously from the first to the fifth day of birth, respectively. For each patient, two concomitant blood and saliva samples corresponding to the trough concentrations were collected 24hours after each caffeine dose. The caffeine concentrations were determined using the EMIT ® 2000 caffeine assay. Thirteen preterm infants were included. The saliva and the serum caffeine concentration increased proportionally to the administered dose. Saliva and serum kinetics were comparable and the saliva caffeine concentrations were correlated to the serum ones (r 2 =0.76). Saliva caffeine monitoring by EMIT is a valid, useful and safe alternative to serum in preterm infants. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  9. Study on the correlation between serum digoxin levels and its therapeutic efficacy and toxicity and pharmacokinetics of digoxin in Thai patients using radionuclide procedures

    International Nuclear Information System (INIS)

    Poopyruchpong, N.

    1984-02-01

    The development of a radioimmunoassay procedure for the measurement of serum digoxin, using a locally raised rabbit anti-digoxin serum, tritiated digoxin from a commercial supplier and dextran-coated charcoal for the separation step, is described. Assay optimization included the determination of optimal antiserum dilution, incubation time and charcoal concentration. Assay validation included the evaluation of assay accuracy, precision and specificity. Results of measurements on sera from a preliminary group of patients undergoing digoxin medication are presented

  10. Serum stabilities of short tryptophan- and arginine-rich antimicrobial peptide analogs.

    Directory of Open Access Journals (Sweden)

    Leonard T Nguyen

    2010-09-01

    Full Text Available Several short antimicrobial peptides that are rich in tryptophan and arginine residues were designed with a series of simple modifications such as end capping and cyclization. The two sets of hexapeptides are based on the Trp- and Arg-rich primary sequences from the "antimicrobial centre" of bovine lactoferricin as well as an antimicrobial sequence obtained through the screening of a hexapeptide combinatorial library.HPLC, mass spectrometry and antimicrobial assays were carried out to explore the consequences of the modifications on the serum stability and microbicidal activity of the peptides. The results show that C-terminal amidation increases the antimicrobial activity but that it makes little difference to its proteolytic degradation in human serum. On the other hand, N-terminal acetylation decreases the peptide activities but significantly increases their protease resistance. Peptide cyclization of the hexameric peptides was found to be highly effective for both serum stability and antimicrobial activity. However the two cyclization strategies employed have different effects, with disulfide cyclization resulting in more active peptides while backbone cyclization results in more proteolytically stable peptides. However, the benefit of backbone cyclization did not extend to longer 11-mer peptides derived from the same region of lactoferricin. Mass spectrometry data support the serum stability assay results and allowed us to determine preferred proteolysis sites in the peptides. Furthermore, isothermal titration calorimetry experiments showed that the peptides all had weak interactions with albumin, the most abundant protein in human serum.Taken together, the results provide insight into the behavior of the peptides in human serum and will therefore aid in advancing antimicrobial peptide design towards systemic applications.

  11. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  12. The radio ligand receptor assay for thyroid stimulating factors

    International Nuclear Information System (INIS)

    Kruck, G.; Kruck, I.

    1978-01-01

    The possible uses of RRA in routine examinations to detect HTSI and physiological TSH concentrations were investigated in this study. The primary difficulties were that the RRA had a low sensitivity using the Mehdi method and the investigation results exhibited large deviations. The authors first investigated the non-specific influences of the incubation medium such as temperature, incubation time, protein used and salts on the 125 I-TSH compared by means of the enriched membrane according to Mehdi. After the modification of the labelling process of 125 I-TSH with Smith's post-purification method, it was possible to improve the sensitivity of the assay system from 100 μU to 10 μU TSH/test. It was now possible to detect HTSI in 67% of the Morbus Basedow sera in clinical tests (compared with 54% in the RRA prior to modification and 19% in the McKenzie assay). The discrepancy between these results and those of Mukhtar et al. - with a HTSI detection in 100% of the cases investigated for the same sensitivity of the assay - remains unexplained. The sensitivity of the RRA is not sufficient to detect TSH in serum, as the standard region for the basal TSH level in the serum is given as between 0.5 and 3.8 μU/ml in the radioimmunoassay. (orig./AJ) [de

  13. [False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-04-01

    Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.

  14. Serum Biopterin and Neopterin Levels as Predictors of Empty Follicles

    Directory of Open Access Journals (Sweden)

    Akihiro Hamuro

    2015-01-01

    Full Text Available Objective This study measured serum and follicular fluid (FF levels of biopterin, neopterin, vascular endothelial growth factor (VEGF, and macrophage colony-stimulating factor (M-CSF in patients receiving mild ovarian stimulation for oocyte retrieval. Patients and Methods Infertile patients who underwent ovarian stimulation were divided into the following: Group 1, no oocyte retrieval ( n = 12, and Group 2, retrieval of more than four oocytes ( n = 13. Median total gonadotropin dose in both groups was 150 IU. Biopterin and neopterin levels were measured using high-performance liquid chromatography. VEGF and M-CSF levels were measured by enzyme-linked immunosorbent assay. Results Compared to Group 2, serum and FF levels of neopterin and VEGF and serum levels of M-CSF were significantly increased, and serum and FF levels of biopterin were significantly decreased in Group 1 ( P < 0.05 each. Conclusion Biopterin and neopterin levels showed similar differences in FF and serum of patients with empty follicles. Decreased biopterin and increased neopterin in serum could predict poor oocyte retrieval.

  15. Neutralization of White Spot Syndrome Virus by Monoclonal Antibodies against Viral Envelope Proteins

    Directory of Open Access Journals (Sweden)

    Hsiu-Hui Shih

    2004-09-01

    Full Text Available Two monoclonal antibodies (MAbs recognizing envelope proteins of the white spot syndrome virus (WSSV, 6E1 against VP28 and 3E8 against VP19, were applied to demonstrate their neutralizing ability to this virus by using both in vitro and in vivo assays. Mixtures of MAb 6E1 with virus filtrate were inoculated into the primary explant monolayer culture derived from the lymphoid Oka organs of Penaeus monodon. Mab was likely to neutralize the infectivity of virus to monolayer since cytopathic effects were apparently blocked in experiment group. WSSV was titrated using Blue-Cell ELISA and the neutralizing index was calculated to be 6.90 for 6EI and 5.83 for 3E8. Neutralized virus fluids injected intramuscularly into post larvae of P. monodon. The shrimp in the positive control, which were injected with WSSV only showed an increasing mortality and a 100% mortality was reached at day 34, whereas no shrimp died in the negative control. The mortality for 6E1 was 6.7% and for 3E8 was 13.3%. These results suggest that Mabs recognizing the WSSV envelope proteins could neutralize viral infectivity to both cultured cells and shrimp.

  16. Egr-1 and serum response factor are involved in growth factors- and serum-mediated induction of E2-EPF UCP expression that regulates the VHL-HIF pathway.

    Science.gov (United States)

    Lim, Jung Hwa; Jung, Cho-Rok; Lee, Chan-Hee; Im, Dong-Soo

    2008-11-01

    E2-EPF ubiquitin carrier protein (UCP) has been shown to be highly expressed in common human cancers and target von Hippel-Lindau (VHL) for proteosomal degradation in cells, thereby stabilizing hypoxia-inducible factor (HIF)-1alpha. Here, we investigated cellular factors that regulate the expression of UCP gene. Promoter deletion assay identified binding sites for early growth response-1 (Egr-1) and serum response factor (SRF) in the UCP promoter. Hepatocyte or epidermal growth factor (EGF), or phorbol 12-myristate 13-acetate induced UCP expression following early induction of Egr-1 expression in HeLa cells. Serum increased mRNA and protein levels of SRF and UCP in the cell. By electrophoretic mobility shift and chromatin immunoprecipitation assays, sequence-specific DNA-binding of Egr-1 and SRF to the UCP promoter was detected in nuclear extracts from HeLa cells treated with EGF and serum, respectively. Overexpression of Egr-1 or SRF increased UCP expression. RNA interference-mediated depletion of endogenous Egr-1 or SRF impaired EGF- or serum-mediated induction of UCP expression, which was required for cancer cell proliferation. Systemic delivery of EGF into mice also increased UCP expression following early induction of Egr-1 expression in mouse liver. The induced UCP expression by the growth factors or serum increased HIF-1alpha protein level under non-hypoxic conditions, suggesting that the Egr-1/SRF-UCP-VHL pathway is in part responsible for the increased HIF-1alpha protein level in vitro and in vivo. Thus, growth factors and serum induce expression of Egr-1 and SRF, respectively, which in turn induces UCP expression that positively regulates cancer cell growth.

  17. Radioimmunoassay for 3,3',5'-triiodo-L-thyronine in unextracted serum: method and clinical results. [/sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Nicod, P.; Burger, A.; Staeheli, V.; Vallotton, M.B.

    1976-05-01

    Serum 3,3',5'-triiodothyronine (rT/sub 3/) was measured with a radioimmunoassay in unextracted serum. The assay was specific and reproducible. The coefficients of variation for three different sera known for high, normal, and low rT/sub 3/ concentrations between assays were 4, 6, and 9 percent and within assays 4, 9, and 7 percent, respectively. In euthyroid subjects 20 to 60 years old, rT/sub 3/ was 450 +- 200 pg/ml (mean +- SD, n = 83). Serum rT/sub 3/ was found to be increased in hyperthyroidism (range: 762 to 2581 pg/ml; n = 11) but also in acute and chronic illness (up to 2400 pg/ml; n = 24) and in anorexia nervosa (536 to 1058 pg/ml; n = 7). In the latter two situations there was mostly an inverse change in serum 3,5,3'-triiodothyronine (T/sub 3/) which was in the low normal range or decreased. These findings suggest a metabolic control of thryoxine deiodination. A low serum rT/sub 3/ was found in 9 of 12 hypothyroid patients and in the serum of one chronically ill patient. Long-term treatment (1 to 7 years) with lithium carbonate slightly reduced serum rT/sub 3/, although the changes were inside the normal range. Kidney function was not found to be necessary for its production, as anephric patients had normal rT/sub 3/ values. In addition, hemodialysis increased serum rT/sub 3/, which is probably due to the heparin therapy.

  18. Identifying the Role of E2 Domains on Alphavirus Neutralization and Protective Immune Responses.

    Directory of Open Access Journals (Sweden)

    James Weger-Lucarelli

    Full Text Available Chikungunya virus (CHIKV and other alphaviruses are the etiologic agents of numerous diseases in both humans and animals. Despite this, the viral mediators of protective immunity against alphaviruses are poorly understood, highlighted by the lack of a licensed human vaccine for any member of this virus genus. The alphavirus E2, the receptor-binding envelope protein, is considered to be the predominant target of the protective host immune response. Although envelope protein domains have been studied for vaccine and neutralization in flaviviruses, their role in alphaviruses is less characterized. Here, we describe the role of the alphavirus E2 domains in neutralization and protection through the use of chimeric viruses.Four chimeric viruses were constructed in which individual E2 domains of CHIKV were replaced with the corresponding domain from Semliki Forest virus (SFV (ΔDomA/ΔDomB/ΔDomC/ ΔDomA+B. Vaccination studies in mice (both live and inactivated virus revealed that domain B was the primary determinant of neutralization. Neutralization studies with CHIKV immune serum from humans were consistent with mouse studies, as ΔDomB was poorly neutralized.Using chimeric viruses, it was determined that the alphavirus E2 domain B was the critical target of neutralizing antibodies in both mice and humans. Therefore, chimeric viruses may have more relevance for vaccine discovery than peptide-based approaches, which only detect linear epitopes. This study provides new insight into the role of alphavirus E2 domains on neutralization determinants and may be useful for the design of novel therapeutic technologies.

  19. Aggravation of serum Hepatocyte Growth Factor levels during hepato carcinogenesis in Rats

    International Nuclear Information System (INIS)

    Abdelgawad, M.R.; Ghareeb, N.A.

    2010-01-01

    Hepatocyte growth factor (HGF) has an essential role during liver development and it plays an important role in the regeneration and repair of injured tissues and acting as a mitogen, motogen and morphogens for a variety of epithelial cells. The role of HGF in carcinogenesis is in straggle and so, the present study aimed to through light through the level of HGF during different steps of carcinogenesis. Forty male rats were given diethylnitrosamine (DEN) in drinking water (100 mg/l) for up to 16 weeks. Eight rats were sacrificed at 8, 12 and 16 weeks. Besides, 8 hepatoma bearing rats were exposed to a single dose gamma irradiation (3 Gy) were sacrificed after 2 weeks from exposure (2 rats died, 36 hrs post irradiation) and 8 hepatoma bearing rats were sacrificed after 4 weeks from receiving a combined antioxidant (N-acetylcysteine and Lmethionine). Serum HGF was assayed by enzyme linked immunosorbent assay (ELISA). Serum HGF level in DEN treated rats and in exposed hepatoma bearing rats was significantly higher than in control rats whereas, serum HGF level after treatment with N acetylcysteine and L-methionine for 4 weeks was significantly decreased than DEN treated rats and concluded that serum HGF may play a role during promotion and progression of hepatocellular carcinoma (HCC) and during treatment

  20. A Functional Henipavirus Envelope Glycoprotein Pseudotyped Lentivirus Assay System

    Directory of Open Access Journals (Sweden)

    Broder Christopher C

    2010-11-01

    Full Text Available Abstract Background Hendra virus (HeV and Nipah virus (NiV are newly emerged zoonotic paramyxoviruses discovered during outbreaks in Queensland, Australia in 1994 and peninsular Malaysia in 1998/9 respectively and classified within the new Henipavirus genus. Both viruses can infect a broad range of mammalian species causing severe and often-lethal disease in humans and animals, and repeated outbreaks continue to occur. Extensive laboratory studies on the host cell infection stage of HeV and NiV and the roles of their envelope glycoproteins have been hampered by their highly pathogenic nature and restriction to biosafety level-4 (BSL-4 containment. To circumvent this problem, we have developed a henipavirus envelope glycoprotein pseudotyped lentivirus assay system using either a luciferase gene or green fluorescent protein (GFP gene encoding human immunodeficiency virus type-1 (HIV-1 genome in conjunction with the HeV and NiV fusion (F and attachment (G glycoproteins. Results Functional retrovirus particles pseudotyped with henipavirus F and G glycoproteins displayed proper target cell tropism and entry and infection was dependent on the presence of the HeV and NiV receptors ephrinB2 or B3 on target cells. The functional specificity of the assay was confirmed by the lack of reporter-gene signals when particles bearing either only the F or only G glycoprotein were prepared and assayed. Virus entry could be specifically blocked when infection was carried out in the presence of a fusion inhibiting C-terminal heptad (HR-2 peptide, a well-characterized, cross-reactive, neutralizing human mAb specific for the henipavirus G glycoprotein, and soluble ephrinB2 and B3 receptors. In addition, the utility of the assay was also demonstrated by an examination of the influence of the cytoplasmic tail of F in its fusion activity and incorporation into pseudotyped virus particles by generating and testing a panel of truncation mutants of NiV and HeV F

  1. Prevaccination Rotavirus Serum IgG and IgA Are Associated With Lower Immunogenicity of Live, Oral Human Rotavirus Vaccine in South African Infants.

    Science.gov (United States)

    Moon, Sung-Sil; Groome, Michelle J; Velasquez, Daniel E; Parashar, Umesh D; Jones, Stephanie; Koen, Antoinette; van Niekerk, Nadia; Jiang, Baoming; Madhi, Shabir A

    2016-01-15

    Live oral rotavirus (RV) vaccines have shown modest efficacy among children in African countries for reasons that are not completely understood. We examined the possible inhibitory effect of preexisting antirotavirus antibodies on immunogenicity of monovalent RV vaccine (RV1). Mother-infant pairs were enrolled at presentation for their routine immunization visit in Soweto, South Africa, when infants were aged 5-8 weeks. Infant serum samples were obtained before the first and second doses of RV1 and 1 month after the second dose. Maternal serum and breast milk samples were obtained prior to administration of each dose of RV1 to infants. RV-specific immunoglobulin G (IgG), IgA, and neutralizing activity in sera of infants and serum or breast milk samples of mothers were measured using enzyme-linked immunosorbent assays or a microneutralization test. Of the 107 serum pairs from infants who were seronegative for RV IgA at enrollment, we observed a strong positive association between IgG titers in pre-dose 1 sera of infants and mothers and significant negative associations between IgG titers in pre-dose 1 sera of infants and seroconversion to RV1 post-dose 1. Similarly, mothers whose infants' IgA seroconverted after RV1 had significantly lower pre-dose 1 IgG titers in sera than those whose infants did not seroconvert. High levels of preexisting serum IgG, including transplacentally acquired maternal IgG, appeared to have an inhibitory effect on the immunogenicity of RV1 among infants and may, in part, contribute to lower efficacy of RV vaccines in this and other low-income settings. Published by Oxford University Press for the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  2. Serum gonadotropins levels in childhood

    International Nuclear Information System (INIS)

    Hertogh, R. De; Vankrieken, L.; Wolter, R.; Vliet, G. Van

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author)

  3. Assessment of serum lipids in nigerians with type-2 diabetes mellitus complications

    International Nuclear Information System (INIS)

    Idogun, E.S.; Unuigbe, E.I.

    2007-01-01

    To assess the serum lipids and lipoprotein cholesterol in patients with complicated type 2 Diabetes Mellitus (DM): Hypertensive diabetics and diabetic nephropathy. This is a cross-sectional study. A total of 52 type 2 DM patients and 20 healthy controls were studied. The patients' population consisted of 23 normotensive diabetics, 16 hypertensive diabetics and 13 patients with diabetic nephropathy. The serum total cholesterol, HDL-cholesterol and triglycerides were assayed in patients and controls, using standardized assay methods. The mean serum total cholesterol was higher in patients than controls. The normotensive diabetic patients had the lowest total cholesterol among the patients groups 4.01+-0.82 mmol/L compared to the hypertensive diabetics 6.01+-0.93 mmol/L and the diabetic nephropathy patients 6.90+-1.20 mmol/L, (P <0.0001). The prevalence of dyslipidaemia in the patients was between 25% - 69%, lowest in the normotensive diabetics and highest in the diabetic nephropathy patients. We hope that these findings will draw specific attention to the management of dyslipidaemia in patients with complicated type 2 DM especially diabetic nephropathy and hypertensive diabetics. (author)

  4. Serum ferritin in recurrent oral ulceration

    International Nuclear Information System (INIS)

    Challacombe, S.J.; Scully, C.; Keevil, B.; Lehner, T.

    1983-01-01

    A sensitive radio-assay for ferritin was developed and used to examine serum ferritin levels in 105 patients with recurrent oral ulceration (ROU), 41 patients with Behcet's syndrome (BS), 42 with other ulcerative oral lesions, 35 patients with non-ulcerative oral lesions and in 78 controls. Ferritin levels increased with age and were significantly higher in males than females. The mean ferritin concentrations in male patients with ROU, BS or with other oral ulcers were significantly reduced in comparison with controls, and in female patients were significantly reduced in those with major aphthous ulcers. The prevalence of low serum ferritin levels was about 8% in patients with ROU, 15% in BS and 9.5% in patients with other ulcerative oral lesions, compared with less than 3% in patients with non-ulcerative oral disorders and in controls. Most of the iron-deficient patients were female. Serum ferritin levels did not directly correlate with serum iron levels and may be a more accurate indicator of iron deficiency. Furthermore, serum ferritin can distinguish between patients with true iron deficiency and those with secondary sideropenia. It is suggested that in a small number of patients, oral ulceration may be a presenting sign of iron deficiency, and that in a further small proportion of patients, ROU already present will be exacerbated by concurrent iron deficiency. Both groups will show a therapeutic response to correction of the iron deficiency. The results suggest that serum ferritin levels are a useful part of the haematological investigatons in patients with ROU. (author)

  5. Role of serum amyloid P component in immune clearance

    International Nuclear Information System (INIS)

    Bristow, D.L.

    1986-01-01

    In order to clarify the mechanism of interaction of serum amyloid P component (SAP) with complement, the interaction of SAP with Clq was studied. It is known that SAP binds Sepharose 4B in the presence of calcium. 125 I-Clq was retained on the Sepharose when purified 125 I-Clq was incubated with SAP prior to affinity chromatography on Sepharose. In the absence of SAP, the 125 I-Clq was not retained. To further examine the interaction of SAP with Clq, SAP was incubated at varying ratios with Clq. These mixtures were examined via crossed immunoelectro-immunoelectrophoresis against goat anti-SAP. A change in the electrophoretic behavior of SAP was observed in the presence of Clq. It was found that SAP interacted with the collagen-like stem of Clq. In these studies, 125 I-SAP was incubated with pepsin digests of Clq in a microtitre solid-phase binding assay. In addition, a microtitre solid-phase binding assay was utilized in order to investigate the possible binding of SAP with IgG. The ability of SAP activate complement as detected by C3 conversion was studied. It was found that SAP activated complement to a limited extent in normal human serum but caused extensive C3 conversion when serum from an individual with decreased levels of Cl inhibitor was used. Furthermore, the action of the complement pathway by SAP in the latter serum was reversed by the addition of exogenous Cl inhibitor, indicating that SAP has the ability to play a role in the regulation of complement via the classical pathway

  6. Longitudinal study of serum placental GH in 455 normal pregnancies

    DEFF Research Database (Denmark)

    Chellakooty, Marla; Skibsted, Lillian; Skouby, Sven O

    2002-01-01

    women with normal singleton pregnancies at approximately 19 and 28 wk gestation. Serum placental GH concentrations were measured by a highly specific immunoradiometric assay, and fetal size was measured by ultrasound. Data on birth weight, gender, prepregnancy body mass index (BMI), parity, and smoking...

  7. Patients with fibromyalgia have normal serum levels of hyaluronic acid

    DEFF Research Database (Denmark)

    Bliddal, Henning; Møller, H J; Schaadt, M

    2000-01-01

    OBJECTIVE: To investigate the levels of hyaluronic acid (HA) in Danish patients with fibromyalgia (FM). METHODS: Serum levels of HA were determined in 53 patients with established FM and 55 control samples using a radiometric assay. Values were correlated to clinical disease severity variables...

  8. Serum complement changes during double-blind food challenges in children with a history of food sensitivity.

    Science.gov (United States)

    Martin, M E; Guthrie, L A; Bock, S A

    1984-04-01

    Serum levels of C3, C4, factor B, properdin, total hemolytic complement and alternative-pathway hemolytic activity were measured before and after double-blind food challenge in 23 children with impressive histories of adverse reactions to foods. The 23 subjects had 11 positive food challenges and 12 negative food challenges. Nine patients with reagin-mediated positive food challenges showed increases in all six complement assays after double-blind food challenge, while the group with negative food challenges showed decreases in five of the six assays. The difference between the two groups for complement changes after double-blind food challenge was significant only for the alternative-pathway assay. Individual subject analysis revealed markedly heterogeneous changes in direction and magnitude within both groups for all complement assays. Therefore, it is concluded that measurement of serum complement levels is not a useful test for the clinical evaluation of a patient with suspected food sensitivity.

  9. Comparison of Intact PTH and Bio-Intact PTH Assays Among Non-Dialysis Dependent Chronic Kidney Disease Patients.

    Science.gov (United States)

    Einbinder, Yael; Benchetrit, Sydney; Golan, Eliezer; Zitman-Gal, Tali

    2017-09-01

    The third-generation bio-intact parathyroid hormone (PTH) (1-84) assay was designed to overcome problems associated with the detection of C-terminal fragments by the second-generation intact PTH assay. The two assays have been compared primarily among dialysis populations. The present study evaluated the correlations and differences between these two PTH assays among patients with chronic kidney disease (CKD) stages 3 to 5 not yet on dialysis. Blood samples were collected from 98 patients with CKD stages 3 to 5. PTH concentrations were measured simultaneously by using the second-generation - PTH intact-STAT and third-generation bio-intact 1-84 PTH assays. Other serum biomarkers of bone mineral disorders were also assessed. CKD stage was calculated by using the CKD-Epidemiology Collaboration (EPI) formula. Serum bio-intact PTH concentrations were strongly correlated but significantly lower than the intact PTH concentrations (r=0.963, Pbio-intact PTH) positively correlated with urea (r=0.523, r=0.504; P=0.002, respectively), phosphorus (r=0.532, r=0.521; Pbio-intact PTH assay detected significantly lower PTH concentrations compared with intact PTH assay. Additional studies that correlate the diagnosis and management of CKD mineral and bone disorders with bone histomorphometric findings are needed to determine whether bio-intact PTH assay results are better surrogate markers in these early stages of CKD. © The Korean Society for Laboratory Medicine

  10. Serum albumin: accuracy and clinical use.

    Science.gov (United States)

    Infusino, Ilenia; Panteghini, Mauro

    2013-04-18

    Albumin is the major plasma protein and its determination is used for the prognostic assessment of several diseases. Clinical guidelines call for monitoring of serum albumin with specific target cut-offs that are independent of the assay used. This requires accurate and equivalent results among different commercially available methods (i.e., result standardization) through a consistent definition and application of a reference measurement system. This should be associated with the definition of measurement uncertainty goals based on medical relevance of serum albumin to make results reliable for patient management. In this paper, we show that, in the current situation, if one applies analytical goals for serum albumin measurement derived from its biologic variation, the uncertainty budget derived from each step of the albumin traceability chain is probably too high to fulfil established quality levels for albumin measurement and to guarantee the accuracy needed for clinical usefulness of the test. The situation is further worsened if non-specific colorimetric methods are used for albumin measurement as they represent an additional random source of uncertainty. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. A novel multiplex poliovirus binding inhibition assay applicable for large serosurveillance and vaccine studies, without the use of live poliovirus.

    Science.gov (United States)

    Schepp, Rutger M; Berbers, Guy A M; Ferreira, José A; Reimerink, Johan H; van der Klis, Fiona R

    2017-03-01

    Large-scale serosurveillance or vaccine studies for poliovirus using the "gold standard" WHO neutralisation test (NT) are very laborious and time consuming. With the polio eradication at hand and with the removal of live attenuated Sabin strains from the oral poliovirus vaccine (OPV), starting with type 2 (as of April 2016), laboratories will need to conform to much more stringent laboratory biosafety regulations when handling live poliovirus strains. In this study, a poliovirus binding inhibition multiplex immunoassay (polio MIA) using inactivated poliovirus vaccine (IPV-Salk) was developed for simultaneous quantification of serum antibodies directed to all three poliovirus types. Our assay shows a good correlation with the NT and an excellent correlation with the ELISA-based binding inhibition assay (POBI). The assay is highly type-specific and reproducible. Additionally, serum sample throughput increases about fivefold relative to NT and POBI and the amount of serum needed is reduced by more than 90%. In conclusion, the polio MIA can be used as a safe and high throughput application, especially for large-scale surveillance and vaccine studies, reducing laboratory time and serum amounts needed. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Evaluation of a magnetic particles-based chemiluminescence enzyme immunoassay for Golgi protein 73 in human serum.

    Science.gov (United States)

    Liu, Xiangyi; Wan, Xiaohua; Lu, Sheng; Zhang, Lijun; Yu, Shaohua; Lu, Xinxin

    2015-05-20

    Golgi protein 73 (GP73) is regarded as a potential serum biomarker for early diagnosis of hepatocellular carcinoma (HCC). We developed a rapid magnetic particles-based chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of serum GP73. Fluorescein isothiocyanate (FITC) and alkaline phosphatase (ALP) were used to label 2 different monoclonal antibodies to GP73. Serum GP73 was captured with labeled antibodies and formed a sandwiched immunoreaction. The magnetic particles (MPs) coated with anti-FITC antibody were used as a means of separation of the GP73 protein from other serum proteins. After adding the enzyme substrate solution, the relative light unit (RLU) was measured. A MPs-CLEIA for serum GP73 was established and evaluated. The RLU was directly proportional to the concentration of GP73. The method linearity was 5-600 μg/l. Limit of the blank was 2.19 μg/l. The intra- and inter-assay imprecision was 73-0.89), and the sensitivity and specificity, with cut-off value of 115.6 μg/l, were 75.4% and 92.1%, respectively. The proposed method demonstrates an acceptable performance for quantifying serum GP73. This assay could be appropriate for routine use in clinical laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  14. Individuals with autism have higher 8-Iso-PGF2α levels than controls, but no correlation with quantitative assay of Paraoxonase 1 serum levels.

    Science.gov (United States)

    Pop, Bianca; Niculae, Alexandru-Ștefan; Pop, Tudor Lucian; Răchișan, Andreea Liana

    2017-12-01

    Autism spectrum disorder (ASD) represents a very large set of neurodevelopmental issues with diverse clinical outcomes. Various hypotheses have been put forth for the etiology of autism spectrum disorder, including issues pertaining to oxidative stress. In this study, we conducted measurements of serum 8-Iso-Prostaglanding F2 α (8-iso-PGF2α, which is the results of non-enzimatically mediated polyunsaturated fatty acid oxidation) in a population of individuals with autism and a control group of age and sex matched controls. A quantitative assay of Paraoxonase 1 (PON1) was conducted. Data regarding comorbidities, structural MRI scans, medication, intelligence quotient (IQ) and Childhood Autism Rating Scale scores (CARS) were also included in our study. Our results show that patients diagnosed with autism have higher levels of 8-iso-PGF2α than their neurotypical counterparts. Levels of this particular metabolite, however, do not correlate with quantitative serum levels of Paraoxonase 1, which has been shown to be altered in individuals with autism. Neither 8-iso-PGF2α nor quantitative levels of PON1 provide any meaningful correlation with clinical or neuroimaging data in this study group. Future research should focus on providing data regarding PON 1 phenotype, in addition to standard quantitative measurements, in relation to 8-iso-PGF2α as well as other clinical and structural brain findings.

  15. An indicator cell assay for blood-based diagnostics.

    Directory of Open Access Journals (Sweden)

    Samuel A Danziger

    Full Text Available We have established proof of principle for the Indicator Cell Assay Platform™ (iCAP™, a broadly applicable tool for blood-based diagnostics that uses specifically-selected, standardized cells as biosensors, relying on their innate ability to integrate and respond to diverse signals present in patients' blood. To develop an assay, indicator cells are exposed in vitro to serum from case or control subjects and their global differential response patterns are used to train reliable, disease classifiers based on a small number of features. In a feasibility study, the iCAP detected pre-symptomatic disease in a murine model of amyotrophic lateral sclerosis (ALS with 94% accuracy (p-Value = 3.81E-6 and correctly identified samples from a murine Huntington's disease model as non-carriers of ALS. Beyond the mouse model, in a preliminary human disease study, the iCAP detected early stage Alzheimer's disease with 72% cross-validated accuracy (p-Value = 3.10E-3. For both assays, iCAP features were enriched for disease-related genes, supporting the assay's relevance for disease research.

  16. Analytical Bias in the Measurement of Serum 25-Hydroxyvitamin D Concentrations Impairs Assessment of Vitamin D Status in Clinical and Research Settings.

    Directory of Open Access Journals (Sweden)

    Lucinda J Black

    Full Text Available Measured serum 25-hydroxyvitamin D concentrations vary depending on the type of assay used and the specific laboratory undertaking the analysis, impairing the accurate assessment of vitamin D status. We investigated differences in serum 25-hydroxyvitamin D concentrations measured at three laboratories (laboratories A and B using an assay based on liquid chromatography-tandem mass spectrometry and laboratory C using a DiaSorin Liaison assay, against a laboratory using an assay based on liquid chromatography-tandem mass spectrometry that is certified to the standard reference method developed by the National Institute of Standards and Technology and Ghent University (referred to as the 'certified laboratory'. Separate aliquots from the same original serum sample for a subset of 50 participants from the Ausimmune Study were analysed at the four laboratories. Bland-Altman plots were used to visually check agreement between each laboratory against the certified laboratory. Compared with the certified laboratory, serum 25-hydroxyvitamin D concentrations were on average 12.4 nmol/L higher at laboratory A (95% limits of agreement: -17.8,42.6; 12.8 nmol/L higher at laboratory B (95% limits of agreement: 0.8,24.8; and 10.6 nmol/L lower at laboratory C (95% limits of agreement: -48.4,27.1. The prevalence of vitamin D deficiency (defined here as 25-hydroxyvitamin D <50 nmol/L was 24%, 16%, 12% and 41% at the certified laboratory, and laboratories A, B, and C, respectively. Our results demonstrate considerable differences in the measurement of 25-hydroxyvitamin D concentrations compared with a certified laboratory, even between laboratories using assays based on liquid chromatography-tandem mass spectrometry, which is often considered the gold-standard assay. To ensure accurate and reliable measurement of serum 25-hydroxyvitamin D concentrations, all laboratories should use an accuracy-based quality assurance system and, ideally, comply with international

  17. Climate Neutral Campus Key Terms and Definitions | Climate Neutral Research

    Science.gov (United States)

    Campuses | NREL Neutral Campus Key Terms and Definitions Climate Neutral Campus Key Terms and Definitions The term climate neutral evolved along with net zero and a number of other "green" and accuracy in these areas lets research campuses know exactly how close they are to climate

  18. Interplay of HIV-1 phenotype and neutralizing antibody response in pathogenesis of AIDS.

    Science.gov (United States)

    Scarlatti, G; Leitner, T; Hodara, V; Jansson, M; Karlsson, A; Wahlberg, J; Rossi, P; Uhlén, M; Fenyö, E M; Albert, J

    1996-06-01

    A majority of human immunodeficiency virus type 1 (HIV-1) infected individuals display a rapid loss of CD4+ lymphocytes with fast progression towards overt acquired immunodeficiency syndrome (AIDS). However, a small proportion of individuals infected by HIV-1 remain immunologically intact for many years. In order to identify factors that might influence the pathogenesis of HIV-1 infection, 21 Italian mothers and 11 Swedish homosexual men were studied for the presence of autologous neutralizing antibodies in serum, biological phenotype of virus isolates and envelope variable region 3 (V3) sequences. The results were compared to the risk of mother-to-child transmission and progression of the disease. The presence of a neutralizing antibody response to the autologous virus as well as a virus with slow replicative capacity were linked both to low risk of mother-to-child transmission and non-progression of the disease. Patients whose peripheral blood mononuclear cells contained a mutation in the tip of the V3 loop (Arg318 to serine, lysine or leucine) significantly more often had neutralizing antibodies to autologous virus isolates containing arginine at this position. Thus, it appears that the interplay and balance between neutralizing antibody response of the host and the biological phenotype of HIV-1 strongly influence pathogenesis.

  19. Digoxin serum levels with respect to some biochemical and clinical indicators

    Energy Technology Data Exchange (ETDEWEB)

    Sedlak, J; Curilla, E [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1984-10-01

    Digoxin serum levels were examined in 40 patients using enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) and correlated with levels of potassium, magnesium, creatinine, urea, glomerular filtration (GF) and with clinical signs of different degrees of digitalis serum concentration. The digoxin level assessed by ELISA and RIA methods correlated fairly closely. An average dependence was found between digoxin levels and levels of creatinine, urea and GF. A correlation was observed between a high level of digoxin and clinical signs of digitalis intoxication.

  20. Digoxin serum levels with respect to some biochemical and clinical indicators

    International Nuclear Information System (INIS)

    Sedlak, J.; Curilla, E.

    1984-01-01

    Digoxin serum levels were examined in 40 patients using enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) and correlated with levels of potassium, magnesium, creatinine, urea, glomerular filtration (GF) and with clinical signs of different degrees of digitalis serum concentration. The digoxin level assessed by ELISA and RIA methods correlated fairly closely. An average dependence was found between digoxin levels and levels of creatinine, urea and GF. A correlation was observed between a high level of digoxin and clinical signs of digitalis intoxication