WorldWideScience

Sample records for serum measurements obtained

  1. Therapeutic serum phenobarbital concentrations obtained using chronic transdermal administration of phenobarbital in healthy cats.

    Science.gov (United States)

    Delamaide Gasper, Joy A; Barnes Heller, Heidi L; Robertson, Michelle; Trepanier, Lauren A

    2015-04-01

    Seizures are a common cause of neurologic disease, and phenobarbital (PB) is the most commonly used antiepileptic drug. Chronic oral dosing can be challenging for cat owners, leading to poor compliance. The purpose of this study was to determine if the transdermal administration of PB could achieve serum PB concentrations of between 15 and 45 μg/ml in healthy cats. Nineteen healthy cats were enrolled in three groups. Transdermal PB in pluronic lecithin organogel (PLO) was applied to the pinnae for 14 days at a dosage of 3 mg/kg q12h in group 1 (n = 6 cats) and 9 mg/kg q12h in group 2 (n = 7 cats). Transdermal PB in Lipoderm Activemax was similarly applied at 9 mg/kg q12h for 14 days in group 3 (n = 6 cats). Steady-state serum PB concentrations were measured at trough, and at 2, 4 and 6 h after the morning dose on day 15. In group 1, median concentrations ranged from 6.0-7.5 μg/ml throughout the day (observed range 0-11 μg/ml). Group 2 median concentrations were 26.0 μg/ml (observed range 18.0-37.0 μg/ml). For group 3, median concentrations ranged from 15.0-17.0 μg/ml throughout the day (range 5-29 μg/ml). Side effects were mild. One cat was withdrawn from group 2 owing to ataxia and sedation. These results show therapeutic serum PB concentrations can be achieved in cats following chronic transdermal administration of PB in PLO at a dosage of 9 mg/kg q12h. More individual variation was noted using Lipoderm Activemax. Transdermal administration may be an alternative for cats that are difficult to medicate orally. © ISFM and AAFP 2014.

  2. Identification and measurement of a folate-binding protein in human serum by radioimmunoassay

    International Nuclear Information System (INIS)

    Da Costa, M.; Rothenberg, S.P.; Fischer, C.; Rosenberg, Z.

    1978-01-01

    Antiserum raised in rabbits against the FBP obtained from CML cells, and the purified binder labeled with 125 I, have been used for an RIA which can measure an immunologically similar protein in human serum. The concentration of the binding protein in normal serums ranged from 1.2 to 9.3 ng/ml, with a mean +- S.E.M. of 3.8 +- 0.4 ng/ml. Elevated values of the binder protein were measured in the serums from patients with folate deficiency, vitamin B 12 deficiency, liver disease, uremia, myeloproliferative diseases, chronic lymphocytic leukemia, and various types of cancer and in the serum from pregnant women. The concentration of the binder protein and the capacity of the serum to specifically bind isotopically labeled PGA correlated poorly, indicating that the binding protein concentration and degree of saturation by endogenous serum folate vary independently in many instances

  3. Measurement of theophylline in human serum

    International Nuclear Information System (INIS)

    Stetten, O. von; Zech, K.

    1980-01-01

    A radioimmunological (RIA-matsup(R) Theophylline) and a HPLC method for the determination of theophylline concentrations in human serum are compared. HPLC as most specific and precise method is not suitable for greater numbers of analyses due to time needed for chromatography. Theophylline-RIA yields excellent results regarding precision, specificity and recovery with excellent correlation and considerable time savings compared to HPLC. (orig.) [de

  4. Measurement of hydroxylated PCB metabolites for Slovakia maternal blood serums

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S.; Athanasiadou, M; Bergman, A. [Stockholm Univ., Stockholm (Sweden); Charles, J.; Zhao, G.; Hertz-Picciotto, I. [California Univ., Sacramento, CA (United States); Petrik, J.; Kocan, A; Trnovec, T. [Bratislava Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    2005-07-01

    Although it is known that polychlorinated biphenyls (PCBs) have adverse impacts on human health, it is not clear if human health impacts are caused by the PCBs or their related hydroxylated (OH) PCB metabolite compounds. This study measured OH-PCB metabolites in the maternal blood serum specimens from the Svidnik and Michalovce areas in eastern Slovakia where PCBs were intensively produced and inadequately disposed. The aim of the study was to characterize and quantify levels of specific OH-PCB metabolites in Slovakian maternal serums exposed to high environmental PCB levels. All specimens were analyzed for PCBs, and a subset of the samples was analyzed for OH-PCB metabolites. The Wallenburg blood extraction method was adopted to separate the OH-PCBs from the blood serums. Final eluates and calibration standards were spiked with PCB209 as an injection standard before gas chromatography (GC) analysis. OH-PCBs in the samples range from 75{+-}9 per cent to 101{+-}11 per cent. Median concentrations of OH-PCB metabolites of Michalovce samples were approximately twice as high as for the Svidnik samples. Concentrations of OH-PCBs of Michalovce blood samples were comparable to samples obtained from northern Canadian female Inuit and Faroe Island females, and were considered to be among the highest OH-PCB concentrations obtained in human blood. It was concluded that further research is needed to understand the placental transfer of OH-PCBs to the fetus, as well as epidemiological approaches to determine the relationship between the exposure of OH-PCB metabolites and child development. 12 refs., 2 figs.

  5. Fluorescence lifetime measurements of native and glycated human serum albumin and bovine serum albumin

    Science.gov (United States)

    Joshi, Narahari V.; Joshi, Virgina O. d.; Contreras, Silvia; Gil, Herminia; Medina, Honorio; Siemiarczuk, Aleksander

    1999-05-01

    Nonenzymatic glycation, also known as Maillard reaction, plays an important role in the secondary complications of the diabetic pathology and aging, therefore, human serum albumin (HSA) and bovine serum albumin (BSA) were glycated by a conventional method in our laboratory using glucose as the glycating agent. Fluorescence lifetime measurements were carried out with a laser strobe fluorometer equipped with a nitrogen/dye laser and a frequency doubler as a pulsed excitation source. The samples were excited at 295 nm and the emission spectra were recorded at 345 nm. The obtained decay curves were tried for double and triple exponential functions. It has been found that the shorter lifetime increases for glycated proteins as compared with that of the native ones. For example, in the case of glycated BSA the lifetime increased from 1.36 ns to 2.30 ns. Similarly, for HSA, the lifetime increases from 1.58 ns to 2.26 ns. Meanwhile, the longer lifetime changed very slightly for both proteins (from 6.52 ns to 6.72 ns). The increase in the lifetime can be associated with the environmental effect; originated from the attachment of glucose to some lysine residues. A good example is Trp 214 which is in the cage of Lys 225, Lys 212, Lys 233, Lys 205, Lys 500, Lys 199 and Lys 195. If fluorescence lifetime technique is calibrated and properly used it could be employed for assessing glycation of proteins.

  6. Periods found in heat measurements obtained by calorimetry

    International Nuclear Information System (INIS)

    Jordan, K.C.

    1984-01-01

    During a span of 640 days, a periodicity of 1.5158 +- 0.0008 days was discovered in successive heater equilibria on Calorimeter No. 127. Measurements were taken at 12-h intervals, with occasional changes of exactly 3 or 6 h in the schedule of measurements. This schedule eliminated all other possible periods except a period of 0.150156 days. Periods of 1.519125 and 1.511283 days were discovered in data on the excess length of day as obtained by the US Naval Observatory over a period of 24 y. These two periods could equally well represent periods of 0.150189 and 0.150112 days, since measurements were obtained only once every 24 h. It is suggested that periods observed in sensitive calorimeters and in length of day data may be related. 1 reference, 6 figures, 5 tables

  7. How to obtain traceability on optical radiation measurements?

    Science.gov (United States)

    Matamoros García, Carlos H.

    2006-02-01

    Traceability to national standards provides confidence in measurements results, granting a guaranty when carrying out governmental rules and when demonstrating conformity with quality requirements such as ISO 9000 or ISO/IEC 17025 (and the Mexican equivalent standards). The appropriate traceability contributes with confidence of the quality of products or services. This paper presents different ways to obtain traceability in Mexico for the optical radiation measurements, mentioning some applications, and highlighting the necessity of having traceability to the appropriate units of the SI. Additionally it present the national standards maintained by Centro Nacional de Metrologia (CENAM), the national metrology institute in Mexico, that give the technical support to Mexican measurements in this field and the international recognition that the personal of the Optics and Radiometry Division had gained in 10 years of development.

  8. Fundamental Characteristics For Building Dymanics Obtained From Microtremors Measurements.

    Science.gov (United States)

    Enomoto, T.; Abeki, N.; Kuramochi, D.; Lanuza, A.; Gonzalez, J.; Schmitz, M.; Navarro, M.

    We are performing the international joint research investigations for the seismic disaster mitigation in Metro Manila between Philippine and Japan from 1994, in Caracas between Venezuela and Japan from 1996 and also in Almeria and Granada between Spain and Japan from 1996. We have made the microtremor measurements at Reinforced Concrete (RC) buildings existed in these cities and evaluated the dynamical characteristics of RC buildings, natural period and damping factor. Even if it·fs necessary to have some discussions about the accuracy of microtremor measurement in order to evaluate the dynamical characteristics because of small amplitude range phenomena. However, the microtremor measurement method is a simple, low cost and realistic method in order to observe and investigate the actual dynamical behavior for obtaining the useful information in many countries. In these international joint research works, we settled the main object to the getting useful information of building dynamical characteristics for the seismic disaster mitigation. So, we observed microtremors at the top floor of several kinds of buildings which have the different conditions, for examples, existed place, building type, dimensional scale and number of stories etc. Then we realized the evaluation of natural period and responded damping factor of building depending on the building conditions as a statistical tendencies. In this paper, mainly we would like to present the investigated results of regression relationship between the natural period of RC building and the number of stories in Philippine and Venezuela, respectively. and also, we summarized the relationship between the natural period of RC building and damping factor considering the surrounding soil condition. We thought that these relations are reasonable and believable results in the small amplitude range evaluated from microtremors.

  9. Advances in bioanalytical techniques to measure steroid hormones in serum.

    Science.gov (United States)

    French, Deborah

    2016-06-01

    Steroid hormones are measured clinically to determine if a patient has a pathological process occurring in the adrenal gland, or other hormone responsive organs. They are very similar in structure making them analytically challenging to measure. Additionally, these hormones have vast concentration differences in human serum adding to the measurement complexity. GC-MS was the gold standard methodology used to measure steroid hormones clinically, followed by radioimmunoassay, but that was replaced by immunoassay due to ease of use. LC-MS/MS has now become a popular alternative owing to simplified sample preparation than for GC-MS and increased specificity and sensitivity over immunoassay. This review will discuss these methodologies and some new developments that could simplify and improve steroid hormone analysis in serum.

  10. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. Seoul (Korea, Republic of)

    2011-03-15

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R{sup 2=}0.838, P<0.001). Serum HBsAg level and serum HBV DNA copies were found to be linearly related by both methods (R{sup 2=}0.067, P=0.316 by IRMA, and R{sup 2=}0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients.

  11. Radioimmunoassay measurements of serum thyrotropin in patients with hypothalamic-pituitary and thyroid diseases

    International Nuclear Information System (INIS)

    Miyai, Kiyoshi; Azukizawa, Mizuo; Azukizawa, Hisako; Hosokawa, Mitsuko; Nishi, Keiko

    1975-01-01

    Serum TSH was measured by means of double antibody radioimmunoassay using a commercial Kit Daiichi, in 21 normal subjects, 200 patients with thyroid disease and 130 patients with hypothalamic-pituitary diseases. Serum TSH concentrations in normal subjects were <2 to 8 μU/ml which rose to 8-40 μU/ml after administration of 500 μg TRH intravenously. Serum TSH was undetectable and did not respond to TRH in all untreated patients and in some euthyroid patients with Graves' disease after treatment. Undetectable TSH and no response to TRH were also observed in most patients with a hyperfunctioning thyroid nodule and those with subacute thyroiditis in the acute phase. In some patients with Hashimoto's thyroiditis and all patients with adult myxedema and cretinism, serum TSH levels were increased and showed hyperresponse to TRH. The ratio of bioassay and radioimmunoassay potency estimates for TSH in sera obtained before TRH was not statistically different from that obtained after TRH administration to patients with primary hypothyroidism. Elevated serum TSH was promptly decreased by the administration of thyroid hormone to the patients. More than 50% of patients with pituitary adenoma, acromegaly and craniopharyngioma showed normal basal TSH and no or low response of TSH to TRH. Administration of TRH failed to stimulate a rise in serum TSH in 2 sisters with isolated TSH deficiency with cretinism. Basal TSH was undetectable and showed delayed response to TRH in patients with anorexia nervosa. (auth.)

  12. Method for obtaining more precise measures of excreted organic carbon

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    A new method for concentrating and measuring excreted organic carbon by lyophilization and scintillation counting is efficient, improves measurable radioactivity, and increases precision for estimates of organic carbon excreted by phytoplankton and macrophytes

  13. Development of a radioimmunoassay for the measurement of human leptin in serum

    International Nuclear Information System (INIS)

    Lagarde, A. R.; Nagy, K.; Forgach, T.; Janoki, G. A.

    2003-01-01

    Leptin is a 16 kDa polypeptide hormone encoded by the obese gene (ob) and secreted by adipose tissue. This hormone plays a major role in energy homeostasis and regulation of food intake and body weight. It also affects the metabolic, neuroendocrine and reproductive systems. Labelling of recombinant human leptin with 125I was best performed by the Chloramine-T method. New Zealand white rabbits were immunised with recombinant human leptin, cross-reaction of obtained antisera was analyzed with 10 different antigens. The separation of bound and free fractions was performed using the second antibody - PEG method. The obtained tracer had specific activities of 2.8-3.3 kBq/μg and had a stability of 5 weeks. A highly specific polyclonal antibody was obtained without measurable cross-reaction against the analysed antigens. Concentrations of human leptin were measured by a single overnight incubation assay with a sensitivity of 0.5 ng/ml and a measuring range of 0.5-100 ng/ml. The intra-assay and inter-assay coefficient of variation was under 6% and 8%, respectively. Recovery ranged from 88% to 106%. Serum human leptin concentrations can be accurately and precisely measured by this new radioimmunoassay. Preliminary results obtained from the measurement of serum leptin in lean, overweight and obese patients are presented. Serum leptin concentrations correlated with body mass index and were significantly higher in women than in men, except for obese patients. (author)

  14. Methane Emission Estimates from Landfills Obtained with Dynamic Plume Measurements

    International Nuclear Information System (INIS)

    Hensen, A.; Scharff, H.

    2001-01-01

    Methane emissions from 3 different landfills in the Netherlands were estimated using a mobile Tuneable Diode Laser system (TDL). The methane concentration in the cross section of the plume is measured downwind of the source on a transect perpendicular to the wind direction. A gaussian plume model was used to simulate the concentration levels at the transect. The emission from the source is calculated from the measured and modelled concentration levels.Calibration of the plume dispersion model is done using a tracer (N 2 O) that is released from the landfill and measured simultaneously with the TDL system. The emission estimates for the different locations ranged from 3.6 to 16 m 3 ha -1 hr -1 for the different sites. The emission levels were compared to emission estimates based on the landfill gas production models. This comparison suggests oxidation rates that are up to 50% in spring and negligible in November. At one of the three sites measurements were performed in campaigns in 3 consecutive years. Comparison of the emission levels in the first and second year showed a reduction of the methane emission of about 50% due to implementation of a gas extraction system. From the second to the third year emissions increased by a factor of 4 due to new land filling. Furthermore measurements were performed in winter when oxidation efficiency was reduced. This paper describes the measurement technique used, and discusses the results of the experimental sessions that were performed

  15. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  16. Accuracy of serum luteinizing hormone and serum testosterone measurements to assess the efficacy of medical castration in prostate cancer patients.

    Science.gov (United States)

    Morote, Juan; Comas, Imma; Ferrer, Roser; Planas, Jacques; Celma, Anna; Regis, Lucas

    2017-10-22

    Luteinizing hormone-releasing hormone (LH-RH) agonists are the standard for androgen deprivation therapy (ADT) in prostate cancer (PCa) patients. Current guidelines recommend serum testosterone measurement to assess the efficacy of ADT and to define castration resistance. However, serum testosterone does not reflect the exclusive effect of castration due to its extratesticular production. The aim of this study is to analyze if serum LH reflects better than serum testosterone the activity of LH-RH agonists. Serum LH and serum testosterone were measured with chemiluminescent immunoassay (CLIA) in a cohort study of 1091 participants: 488 PCa patients "on LH-RH agonists", 303 "off LH-RH agonist" in whom LH-RH agonists were withdrawn, and 350 men with PCa suspicion "no LH-RH agonist" who never received LH-RH agonists. In a validation cohort of 147 PCa patients, 124 on "LH-RH agonists" and 19 "off LH-RH agonists", serum testosterone was also measured with liquid chromatography and tandem mass spectrometry (LC MSMS). The area under the curve (AUC) to distinguish patients "on versus off LH-RH agonists" was 0.997 for serum LH and 0.740 for serum testosterone, P < 0.001. The 97.5 percentile of serum LH in patients "on LH-RH agonists" was 0.97 U/L, been the most efficient threshold 1.1 U/L. The AUCs for serum LH, testosterone measured with CLIA and with LC MSMS, in the validation cohort, were respectively 1.000, 0.646 and 0.814, P < 0.001. The efficacy to distinguish patients "on versus off LH-RH agonists" was 98.6%, 78.3%, and 89.5% respectively, using 1.1 U/L as threshold for serum LH and 50 ng/dL for serum testosterone regardless the method. Serum LH is more accurate than serum testosterone regardless the method, to distinguish patients "on versus off LH-RH agonists". The castrate level of serum LH is 1.1 U/l. These findings suggest that assessment of LH-RH agonist efficacy and castration resistance definition should be reviewed.

  17. Measurement results obtained from air quality monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Turzanski, P.K.; Beres, R. [Provincial Inspection of Environmental Protection, Cracow (Poland)

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  18. Comparison of biuret and refractometry methods for the serum total proteins measurement in ruminants.

    Science.gov (United States)

    Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S

    2017-12-01

    Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P  .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.

  19. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    Science.gov (United States)

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  20. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    Science.gov (United States)

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  1. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R 2= 0.838, P 2= 0.067, P=0.316 by IRMA, and R 2= 0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients

  2. Production of antiserum and development of radioimmunoassay for progesterone measurement in serum

    International Nuclear Information System (INIS)

    Abdalla, O.M; Abbas, S.H.

    2004-03-01

    The anti progesterone antibody was obtained by injection of local sudanese sheep (bevies arias) intramuscularly and subcutaneously using 11-a-hydroxy progesterone conjugated with bovine serum albumin and emulsified in friend's adjuvant. The blood samples collected one week after the 3 rd injection was tested for anti-progesterone antibodies. Different dilutions of antisera in Pbs containing 0.0.1 % BSA and 0.1 % Na N 3 (Ph 7.4) were made. Using these dilutions, polystyrene balls of 6.4 mm diameter were coated with a coating volume of 500 μ1/bead.The antibody dilution of 1/200000 was selected and used for assembling a kit to measure progesterone level in serum. Optimization of the assay condition resulted in the following recipes: Fifty μ1 of standard or Qc (Low, normal and high) from Bio Rad for 2 hours. The reaction medium aspirated, washed twice and read for 100 seconds in gamma counter. Assay validation tests including Linearity, recovery, reproducibility and comparability were done. In regards to linearity, the measured concentrations of progesterone in serum samples were plotted against the expected values. The correlation coefficient was 0.997 and a linear regression equation was Y=1.1019+0.9895 X. The mean recovery was 96.86% of the sample replicates ranged from 0.2% to 6%. between assay reproducibility was assessed fro the results obtained from 3 samples which were used for quality control in different assays. The results obtained were in the reference range and were close to each other. Comparison between local and American Dpc reagents for progesterone determination in serum showed high correlation high correlation where r 0.9492.(Author)

  3. Measurement of rat serum FSH by radioreceptor assay and comparison with radioimmunoassay

    International Nuclear Information System (INIS)

    Minegishi, Takashi; Igarashi, Masao; Wakabayashi, Katsumi

    1980-01-01

    Follicle stimulating hormone (FSH) in rat serum is successfully measured by a radioreceptor assay system employing PMS-treated immature rat ovary. The non-specific inhibitory effect of serum was partially overcome by the addition of merthiolate to every component, while the residual effect was compensated for by using FSH-free serum which was prepared by passing the pooled female diestrous rat sera through an immunoadsorbent column packed with anti-ovine FSH-coupled Sepharose 4B. The assay system consisted of 100 μl of Tris-MgCl 2 -BSA or standard, 100 μl of FSH-free serum or sample, 100 μl of the receptor preparation and 100 μl of 125 I-FSH. The incubation was carried out for 4 hr at 37 0 C and 500 μl of cold Tris-MgCl 2 -BSA was used for the termination. Serum FSH could be measured within a range of 0.125 - 16 ng NIAMDD rat FSH I-3/tube. The mean within-assay coefficient of variation was 10.5%. The mean between-assay coefficient of variation was 11.0%. The assay values obtained by RRA showed a good correlation to those by RIA under the same physiological states of the animals. The ratio of the assay values, RRA/RIA, was found to change according to the sex and the physiological states, e.g. around 1.3 in normal males and 1.7 in orchiectomized animals and 2.21 in female rats. Serum FSH levels in female rats obtained by RRA and RIA changed almost in parallel until 20:00 (hr) of proestrous day, but after the first surge of serum FSH they were not parallel. These facts seem to indicate possible changes in the affinity of FSH with its receptor according to the state of animals and lead to the problem of the heterogeneity of FSH. (author)

  4. Changes of serum dehydroepiandrosterone in patients with depression measured by radioimmunoassay

    International Nuclear Information System (INIS)

    Zhang Haisan; Zhang Hongxing; Meng Yan; Zhao Jingyuan; Du Yunhong

    2009-01-01

    To evaluate the reliability of radioimmunoassay for measuring serum neurosteroid dehydroepiandrosterone (DHEA) and to investigate the changes of serum DHEA level in depressive patients after treatment, the serum levels of DHEA in 40 health controls and in 40 depressive patients before and after treatment were measured by radioimmunassay. The results showed that the serum levels of DHEA in patient group before treatment were significantly lower than that in control group (P=0.001); it increased significantly after treatment (P=0.000) and were higher than that in control group (P=0.001). The serum levels of DHEA in both male and female patients after treatment were increased significantly compared with that before treatment (P=0.000). Radioimmunassay is convenient and reliable method and easy to use for the measurement of serum DHEA. The results indicate that the lower serum DHEA level in patients may be related to depression, it can be increased after treatment with antidepressant. (authors)

  5. Genetic and phenotypic correlations between surrogate measures of insulin release obtained from OGTT data

    DEFF Research Database (Denmark)

    Gjesing, Anette Marianne Prior; Ribel-Madsen, Rasmus; Harder, Marie Neergaard

    2015-01-01

    closely related to fasting insulin with a genetic correlation of 0.85. The effects of 82 selected susceptibility single nucleotide polymorphisms on these insulin secretion indices supported our interpretation of the data and added insight into the biological differences between the examined traits......AIMS/HYPOTHESIS: We examined the extent to which surrogate measures of insulin release have shared genetic causes. METHODS: Genetic and phenotypic correlations were calculated in a family cohort (n = 315) in which beta cell indices were estimated based on fasting and oral glucose-stimulated plasma...... glucose, serum C-peptide and serum insulin levels. Furthermore, we genotyped a large population-based cohort (n = 6,269) for common genetic variants known to associate with type 2 diabetes, fasting plasma glucose levels or fasting serum insulin levels to examine their association with various indices...

  6. Radioimmunoassay for measurement of thyroxine (T4) and triiodothyonine (T3) in blood serum

    International Nuclear Information System (INIS)

    Chopra, I.J.

    1975-01-01

    This invention relates to a highly accurate, rapid and simple estimation of thyroxine (T 4 ) directly from blood serum and also relates to the accurate measurement of triiodo-L-thyronine (T 3 ) directly from blood serum. More specifically, the invention relates to a rapid, specific and reliable radioimmunoassay (RIA) technique for measurement of both T 4 and T 3 in unextracted serum. The method requires very small amounts of serum, e.g., 25 microliters (μl) to measure T 4 concentration in nearly all specimens representing clinical states of eu-, hypo- and hyperthyroidism, and 250 μl to measure T 3 concentrations in specimens representing most clinical states

  7. Reliability of soluble IL-2 receptor measurements obtained with enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Akiyama, Mitoshi; Takaishi, Masatoshi; Murakami, Yoshie; Ueda, Ryuzo; Yamakido, Michio; Tsubokura, Tokuo.

    1989-09-01

    Using an enzyme-linked immunosorbent assay (ELISA), human soluble interleukin-2 receptors (IL-2R) were measured in the serum of patients with various autoimmune system diseases. To study the sensitivity and specificity of the assay, soluble IL-2Rs were measured in the culture supernatants and in the cell extracts of peripheral blood mononuclear cells activated with phytohemagglutinin (PHA), purified protein derivative of tuberculin, and allogeneic lymphocytes, as well as in the serum of patients with various collagen diseases. The results correlated well with reports from other laboratories. For example, when stimulated by PHA, the greatest amount of soluble IL-2Rs was produced at the fastest rate. In addition, soluble IL-2R levels in the serum of collagen disease patients were significantly higher than those in healthy persons, who themselves exhibited low levels of detectable soluble IL-2Rs. It is hoped that reliable ELISA measurements of soluble IL-2Rs in the serum of atomic bomb survivors will assist in the interpretation of data collected during the work described in RP 2-87, a study of autoimmunity and autoimmune diseases in the Adult Health Study. (author)

  8. Automated two-site immunofluorescent assay for the measurement of serum chromogranin A.

    Science.gov (United States)

    Popovici, Théodora; Moreira, Baptiste; Schlageter, Marie-Hélène; Bories, Phuong-Nhi

    2014-01-01

    Chromogranin A (CgA) is the best-characterized biological marker common to neuroendocrine tumours and is therefore recommended for their diagnosis. The measurement of serum CgA is of great importance for reaching an early diagnosis and thus reducing the delay before treatment is instigated. The Kryptor CgA assay is the first fully automated assay available. The aim of this study was to evaluate its analytical performance. The imprecision and linearity of the Kryptor CgA assay were evaluated. This assay was compared with the Cis Bio CgA RIA assay in 78 serum samples. Its clinical utility was assessed in serum from 229 patients. The study performed on imprecision of Kryptor measurements showed intra- and inter-run CVs ≤ 5%. The study of linearity showed a satisfactory recovery rate for CgA concentrations up to 1200 μg/L. The Kryptor and RIA assays agreed well on the basis of the cut-off values provided by the two manufacturers. The Bland and Altman plot of the values obtained (range: 20-5560 μg/L) provided a mean difference of -10.1 μg/L (SD: 116). The clinical sensitivities of Kryptor CgA for diagnosis of pheochromocytoma and paraganglioma (n 20) and gastroenteropancreatic NETs (n 17) were respectively 100 and 94%. The Kryptor assay for CgA shows reliable analytical and clinical characteristics and allows a fast delivery of results. © 2013.

  9. Microcantilever based disposable viscosity sensor for serum and blood plasma measurements.

    Science.gov (United States)

    Cakmak, Onur; Elbuken, Caglar; Ermek, Erhan; Mostafazadeh, Aref; Baris, Ibrahim; Erdem Alaca, B; Kavakli, Ibrahim Halil; Urey, Hakan

    2013-10-01

    This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23°C and 37°C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 μl and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges. Copyright © 2013. Published by Elsevier Inc.

  10. A systematic approach to obtain validated Partial Least Square models for predicting lipoprotein subclasses from serum NMR spectra

    NARCIS (Netherlands)

    Mihaleva, V.V.; van Schalkwijk, D.B.; de Graaf, A.A.; van Duynhoven, J.; van Dorsten, F.A.; Vervoort, J.; Smilde, A.; Westerhuis, J.A.; Jacobs, D.M.

    2014-01-01

    A systematic approach is described for building validated PLS models that predict cholesterol and triglyceride concentrations in lipoprotein subclasses in fasting serum from a normolipidemic, healthy population. The PLS models were built on diffusion-edited 1H NMR spectra and calibrated on

  11. A systematic approach to obtain validated partial least square models for predicting lipoprotein subclasses from serum NMR spectra

    NARCIS (Netherlands)

    Mihaleva, V.V.; Schalkwijk, van D.B.; Graaf, de A.A.; Duynhoven, van J.P.M.; Dorsten, van F.A.; Vervoort, J.J.M.; Smilde, A.K.; Westerhuis, J.A.; Jacobs, D.M.

    2014-01-01

    A systematic approach is described for building validated PLS models that predict cholesterol and triglyceride concentrations in lipoprotein subclasses in fasting serum from a normolipidemic, healthy population. The PLS models were built on diffusion-edited (1)H NMR spectra and calibrated on

  12. A systematic approach to obtain validated partial least square models for predicting lipoprotein subclasses from serum nmr spectra

    NARCIS (Netherlands)

    Mihaleva, V.V.; Schalkwijk, D.B. van; Graaf, A.A. de; Duynhoven, J. van; Dorsten, F.A. van; Vervoort, J.; Smilde, A.; Westerhuis, J.A.; Jacobs, D.M.

    2014-01-01

    A systematic approach is described for building validated PLS models that predict cholesterol and triglyceride concentrations in lipoprotein subclasses in fasting serum from a normolipidemic, healthy population. The PLS models were built on diffusion-edited 1H NMR spectra and calibrated on

  13. Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

    International Nuclear Information System (INIS)

    Zhang, Jie; Hisada, Aya; Yoshinaga, Jun; Shiraishi, Hiroaki; Shimodaira, Kazuhisa; Okai, Takashi; Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa

    2013-01-01

    Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

  14. Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Hisada, Aya [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Yoshinaga, Jun, E-mail: junyosh@k.u-tokyo.ac.jp [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Shiraishi, Hiroaki [National Institute for Environmental Studies, Onogawa 16-2, Tsukuba, Ibaraki 305-8563 (Japan); Shimodaira, Kazuhisa; Okai, Takashi [Department of Obstetrics and Gynecology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan); Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa [Department of Psychiatry and Neurology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan)

    2013-11-15

    Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

  15. Some metabolic and anthropometric variables in obes children by measuring serum insulin, and leptin

    International Nuclear Information System (INIS)

    Nour Eldin, A.M.

    2004-01-01

    The present study aimed to assess serum leptin level in obese children to study its correlation with some metabolic variables as serum insulin and serum glucose. The study was conducted on 30 obese children of age from 9-14 years with body mass index (BMI) > 27.8 Kg/m 2 . All children were subjected to history taking, clinical examination, anthropometric measurements and laboratory investigations including fasting serum leptin, insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml) compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric measurements and laboratory investigations including fasting serum insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml)compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric variables was positively correlated with BMI r s = 0.68, (p s = 0.59.(p<0.01). It is concluded that serum leptin is increased in obesity and its concentration effects the size of the body. Moreover, the relation of leptin and insulin suggests a positive role of leptin in insulin resistance, which are common metabolic disorders associated with obesity

  16. The Valuable Role of Measuring Serum Lipid Profile in Cancer Progression

    Directory of Open Access Journals (Sweden)

    Farahnaz Ghahremanfard

    2015-09-01

    Full Text Available Objective: Serum lipid levels are not only associated with etiology, but also with prognosis in cancer. To investigate this issue further, we aimed to evaluate the serum levels of lipids in association with the most important prognostic indicators in cancer patients at the start of chemotherapy. Methods: In a retrospective cross-sectional study, using existing medical records obtained from 2009–2014, the data of all incident cancer cases in Iranian patients referred to the Semnan oncology clinic for chemotherapy were analyzed. Data on demographics, cancer type, prognostic indicators (e.g. lymph node involvement, metastasis, and stage of disease, as well as the patient’s lipid profile were collected. We used multiple logistic regression models to show the relationship between prognosis indicators and lipid profile adjusting for age, gender, and type of cancer. Results: The data of 205 patients was gathered. We found a significant difference in the lipid profile between different types of cancers (breast, colon, gastric, and ovarian. With the exception of high-density lipoprotein levels in women, which were higher than in men, the means of other lipid profiles were similar between the genders. There was a significant association between higher levels of low-density lipoprotein (LDL >110mg/dL in the serum and metastasis (adjusted odds ratio=2.4, 95% CI 1.2–3.5. No significant association was reported between lipid profile and lymph nodes involvement and stage of the disease. Conclusion: Our study suggested a benefit of measuring serum levels of lipids for predicting cancer progression. Increased LDL levels can be considered a predictive factor for increasing the risk of metastasis.

  17. Measurements of serum-free thyroid hormone concentrations by ultrafiltration

    International Nuclear Information System (INIS)

    Konno, Norimichi; Hagiwara, Kohji; Taguchi, Hideo; Murakami, Shigeki; Taguchi, Shizuko

    1987-01-01

    An ultrafiltration method (UF) for measuring free thyroxine (FT 4 ) and free triiodothyronine (FT 3 ) using the Diaflow YM membrane (Centricon-10) is described. The results are compared with those by equilibrium dialysis (ED) and also by mathematical calculations derived from T 4 , T 3 , and binding protein concentrations. The precision with the UF method was excellent. The normal ranges of FT 4 and FT 3 by the three methods are all comparable. There was a high degree of correlation of FT 4 or FT 3 results by UF with those by ED and by calculation (r = 0.940 - 0.974, n = 161, P 4 and FT 3 by all methods agreed well for hyperthyroidism, hypothyroidism, and for patients with low T 4 -binding globulin. The mean FT 3 in pregnancy was lower than the normal value for all methods, and FT 4 concentrations by UF and calculation also decreased in late pregnancy. The mean FT 4 by UF and ED in low T 3 syndrome were significantly higher than in the normal controls, while the calculated FT 4 was lower. The FT 3 in low T 3 syndrome distributed normal to subnormal in all methods. These results indicate that a) the UF method is a reliable reference method for measuring FT 4 and FT 3 concentrations; b) the UF results agree well with those by ED and also with theoretically derived values in subjects with thyroid diseases and TBG abnormalities; c) for patients with low T 3 syndrome, the FT 4 results obtained by UF and ED are similarly discrepant from the calculated results, implying the existence of binding inhibitor(s) which affect both UF and ED measurements. (author)

  18. Clinical significance of combined measurement of serum sex hormones in secondary amenorrhea

    International Nuclear Information System (INIS)

    Chen Boxun; Chen Yue; Gan Xilun

    2004-01-01

    Objective: To study the clinical significance of changes of levels of serum sex hormones in the diagnosis of the types of secondary amenorrhea. Methods: Serum sex hormones levels were measured with chemiluminescence in 100 patients with secondary amenorrhea and 42 controls. The serum hormones determined were: estradiol (E 2 )-, progesterone (PROG), follicle stimulating hormone (FSH)-, luteinizing hormone (LH), prolactin (PRL), testosterone (TSTO). Results: Patients with secondary amenorrhea had significantly higher levels of serum FSH, LH and PRL ( P 2 (P<0.05) than those in the controls. Serum levels of PROG and TSTO were about the same in the patients and controls. Conclusion: Determination of serum hormones levels with chemiluminescence is clinically useful for diagnosis of the types of secondary amenorrhea. (authors)

  19. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... of serum HIV RNA (p normal allele (p

  20. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    Science.gov (United States)

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  1. Radioimmunoassay measurement of creatine kinase BB in the serum of schizophrenic patients

    Energy Technology Data Exchange (ETDEWEB)

    Lerner, M H; Friedhoff, A J [New York Univ., NY (USA). Medical Center

    1980-10-23

    Brain type creatine kinase (BB) isoenzyme was measured using a highly sensitive and specific radioimmunoassay procedure (limit of detection, 1 ..mu..g/l of sample) in two schizophrenic populations, an acute non-medicated group consisting of 35 subjects and a chronic group of 15 subjects. Since the assay can also measure the B subunit of MB isoenzyme, patients were selected so as to exclude subjects with possible heart, kidney or other ailments which might result in an increased serum creatine kinase B subunit. Both the acute schizophrenics (3.0 +- 0.23) x S.E.M. and the chronic schizophrenics (2.9 +- 0.33) had serum levels of creatine kinase BB similar to those of controls (2.8 +- 0.21) and non-cardiac patients (3.5 +- 0.58). Patients having myocardial infarction or neurovascular surgery had elevated creatine kinase B subunit. Similar but much less sensitive quantitative results were obtained using agarose multizonal electrophoresis.

  2. Radioimmunoassay measurement of creatine kinase BB in the serum of schizophrenic patients

    International Nuclear Information System (INIS)

    Lerner, M.H.; Friedhoff, A.J.

    1980-01-01

    Brain type creatine kinase (BB) isoenzyme was measured using a highly sensitive and specific radioimmunoassay procedure (limit of detection, 1 μg/l of sample) in two schizophrenic populations, an acute non-medicated group consisting of 35 subjects and a chronic group of 15 subjects. Since the assay can also measure the B subunit of MB isoenzyme, patients were selected so as to exclude subjects with possible heart, kidney or other ailments which might result in an increased serum creatine kinase B subunit. Both the acute schizophrenics (3.0 +- 0.23) x S.E.M. and the chronic schizophrenics (2.9 +- 0.33) had serum levels of creatine kinase BB similar to those of controls (2.8 +- 0.21) and non-cardiac patients (3.5 +- 0.58). Patients having myocardial infarction or neurovascular surgery had elevated creatine kinase B subunit. Similar but much less sensitive quantitative results were obtained using agarose multizonal electrophoresis. (Auth.)

  3. Evaluation of the correlation between transcutaneous measurement andconcentration ofbilirubin inthe blood serum ofa newborn

    Directory of Open Access Journals (Sweden)

    Małgorzata Morawiecka-Pietrzak

    2016-09-01

    Full Text Available Aim: Due to the potential toxicity of high concentrations of bilirubin, newborns are monitored in terms of the potential emergence of a group at risk of the development of severe hyperbilirubinaemia and, rarely, encephalopathy and kernicterus. The transcutaneous measurement of bilirubin, as a non-invasive method, is applied in neonatal centres. The paper presents an evaluation of the correlation between the transcutaneous measurement and the concentration of bilirubin in the blood serum of a newborn, taking into consideration the reduction of the necessity to carry out blood tests related to the transcutaneous measurement. Material and method: The analysis comprised 1,076 medical histories of newborns hospitalised at the Department of Neonatology of the Municipal Hospital in Zabrze in the period from 1 January to 31 December 2013 (a primary referral centre. The inclusion criteria for the study were: performing a simultaneous transcutaneous measurement and a blood serum concentration measurement of bilirubin, gestational age ≥35 Hbd and birth weight >2,500 g. 272 children were qualified for the study. Results: Boys constituted 51.7%, and girls 48.3% of the research group. The mean gestational age was 38.7 Hbd and the mean birth weight was 3,323.4 g; 67.8% of the children were born by natural labour and 32.2% – by caesarean section. The mean Apgar score in the 5th minute was 9.8 points. The measurement of the concentration of bilirubin was performed on average on the 3.9 day of life. The mean transcutaneous measurement was 9.67 mg% (2.7–17.2 mg% and the mean concentration of bilirubin in the blood serum was 13.18 mg% (7.0–19.8 mg%; the difference was 3.5 mg% (p < 0.0001. A statistically significant positive correlation was found between the concentrations of bilirubin obtained in the transcutaneous measurement and the concentrations in the blood serum (according to Spearman, r

  4. Associations of Body Composition Measurements with Serum Lipid, Glucose and Insulin Profile: A Chinese Twin Study

    Science.gov (United States)

    Liao, Chunxiao; Gao, Wenjing; Cao, Weihua; Lv, Jun; Yu, Canqing; Wang, Shengfeng; Zhou, Bin; Pang, Zengchang; Cong, Liming; Wang, Hua; Wu, Xianping; Li, Liming

    2015-01-01

    Objectives To quantitate and compare the associations of various body composition measurements with serum metabolites and to what degree genetic or environmental factors affect obesity-metabolite relation. Methods Body mass index (BMI), waist circumference (WC), lean body mass (LBM), percent body fat (PBF), fasting serum high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), triglycerides (TG), total cholesterol (TC), glucose, insulin and lifestyle factors were assessed in 903 twins from Chinese National Twin Registry (CNTR). Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from fasting serum glucose and insulin. Linear regression models and bivariate structural equation models were used to examine the relation of various body composition measurements with serum metabolite levels and genetic/environmental influences on these associations, respectively. Results At individual level, adiposity measurements (BMI, WC and PBF) showed significant associations with serum metabolite concentrations in both sexes and the associations still existed in male twins when using within-MZ twin pair comparison analyses. Associations of BMI with TG, insulin and HOMA-IR were significantly stronger in male twins compared to female twins (BMI-by-sex interaction p = 0.043, 0.020 and 0.019, respectively). Comparison of various adiposity measurements with levels of serum metabolites revealed that WC explained the largest fraction of variance in serum LDL-C, TG, TC and glucose concentrations while BMI performed best in explaining variance in serum HDL-C, insulin and HOMA-IR levels. Of these phenotypic correlations, 64–81% were attributed to genetic factors, whereas 19–36% were attributed to unique environmental factors. Conclusions We observed different associations between adiposity and serum metabolite profile and demonstrated that WC and BMI explained the largest fraction of variance in serum lipid profile and insulin

  5. Serum Autoantibody Measurement for the Detection of Hepatocellular Carcinoma

    Science.gov (United States)

    Middleton, Catrin H.; Irving, William; Robertson, John F. R.; Murray, Andrea; Parsy-Kowalska, Celine B.; Macdonald, Isabel K.; McElveen, Jane; Allen, Jared; Healey, Graham F.; Thomson, Brian J.; Ryder, Stephen J.; Holdenrieder, Stefan; Chapman, Caroline J.

    2014-01-01

    Background Individuals with liver disease, and especially those with Hepatitis B or C, are at an increased risk of developing hepatocellular carcinoma (HCC) which is the third most common cause of cancer-related death worldwide. Inadequate screening tests largely account for presentation of advanced tumours and high mortality rates. Early detection of HCC amongst high-risk groups is paramount in improving prognosis. This research aimed to further characterise the previously described humoral immune response raised to tumour-associated antigens (TAAs) in the serum of patients with HCC. Methods Serum from 96 patients with confirmed HCC, 96 healthy controls matched for age and sex, 78 patients with confirmed liver cirrhosis and 91 patients with confirmed chronic liver disease were analysed for the presence of IgG autoantibodies raised to 41 recombinant TAAs/antigen fragments by ELISA. Results Varying autoantibody specificities (97–100%) and sensitivities (0–10%) were observed to individual TAAs. A 21-antigen panel achieved a specificity of 92% and sensitivity of 45% for the detection of HCC. This same panel identified 21% of 169 high-risk controls as having elevated autoantibody levels. A reproducible panel of 10 antigens achieved a specificity of 91% and sensitivity of 41% in HCC. 15% of 152 high-risk controls gave positive results with this panel. Conclusions This minimally invasive blood test has the potential to offer advantages over currently available tools for the identification of HCC amongst pre-disposed patients. Results are comparable to current gold standards in HCC (Ultrasonography) and to similar tests in other cancers (EarlyCDT-Lung). PMID:25093332

  6. Serum autoantibody measurement for the detection of hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Catrin H Middleton

    Full Text Available BACKGROUND: Individuals with liver disease, and especially those with Hepatitis B or C, are at an increased risk of developing hepatocellular carcinoma (HCC which is the third most common cause of cancer-related death worldwide. Inadequate screening tests largely account for presentation of advanced tumours and high mortality rates. Early detection of HCC amongst high-risk groups is paramount in improving prognosis. This research aimed to further characterise the previously described humoral immune response raised to tumour-associated antigens (TAAs in the serum of patients with HCC. METHODS: Serum from 96 patients with confirmed HCC, 96 healthy controls matched for age and sex, 78 patients with confirmed liver cirrhosis and 91 patients with confirmed chronic liver disease were analysed for the presence of IgG autoantibodies raised to 41 recombinant TAAs/antigen fragments by ELISA. RESULTS: Varying autoantibody specificities (97-100% and sensitivities (0-10% were observed to individual TAAs. A 21-antigen panel achieved a specificity of 92% and sensitivity of 45% for the detection of HCC. This same panel identified 21% of 169 high-risk controls as having elevated autoantibody levels. A reproducible panel of 10 antigens achieved a specificity of 91% and sensitivity of 41% in HCC. 15% of 152 high-risk controls gave positive results with this panel. CONCLUSIONS: This minimally invasive blood test has the potential to offer advantages over currently available tools for the identification of HCC amongst pre-disposed patients. Results are comparable to current gold standards in HCC (Ultrasonography and to similar tests in other cancers (EarlyCDT-Lung.

  7. Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction-Measurement by ELISA.

    Directory of Open Access Journals (Sweden)

    Shozo Yokoyama

    Full Text Available Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA.One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH. Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay.A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference and the addition of bovine serum albumin (BSA resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA.We optimized an easy and rapid detection method for assessment of

  8. Control of treatment of differentiated thyroid carcinoma by measurement of thyroglobulin in serum

    International Nuclear Information System (INIS)

    Hagemann, J.; Schneider, C.

    1978-01-01

    The presence of thyroglobulin in serum of patients with differentiated thyroid carcinoma was studied by a specific radioimmunoassay. Seventy-three patients with thyroid carcinomata were examined, 16 of whom had pulmonary or skeletal metastase, 11 local metastases, and the others no metastases. Patients with generalized metastases had very high serum thyroglobulin concentrations while those with local metastases had slightly elevated or normal concentrations. Those with remaining thyroid tissue had mainly normal thyroglobulin levels and patients with neither metastases nor remaining thyroid tissue had undetectable serum thyroglobulin. In seven patients with metastases it was possible to observe the development of serum thyroglobulin after 131 I treatment. In all cases the serum thyroglobulin concentration paralleled the development of the clinical status. Elevated serum thyroglobulin was also found in benign thyroid diseases such as hyperthyroidism and endemic goitre. Measurement of thyroglobulin in serum is therefore of little value in differentiating between benign and malignant thyroid diseases, but it is a good method for the follow-up control of patients with differentiated thyroid carcinomata. Because normal thyroglobulin levels do not exclude local metastases, additional examinations are necessary if normal thyroglobulin levels are found. When thyroglobulin is undetectable, metastases can be excluded and the measurement of thyroglobulin in serum can replace all other methods in the follow-up control. (author)

  9. Combined measurement of maternal serum FE3 and HPL for determination of fetus-placenta function

    International Nuclear Information System (INIS)

    Peng Yangshui; Li Gefang; Xia Dingwen

    2003-01-01

    Objective: To investigate the clinical application of combined measurement of maternal serum FE 3 and HPL for determination of fetus-placenta function. Methods: Maternal serum FE 3 and HPL levels were measured with RIA in 86 complicated and 39 non-complicated pregnant women. Results: Serum FE 3 contents in pregnant women complicated with hypertensive syndrome, intrauterine fetal distress, gestation above 33 wks complicated with diabetes and 3rd grade placenta were significantly lower than those in non-complicated ones (p 3 and HPL could improve the early diagnosis of high-risk pregnancies

  10. Bivariate analysis of basal serum anti-Mullerian hormone measurements and human blastocyst development after IVF

    LENUS (Irish Health Repository)

    Sills, E Scott

    2011-12-02

    Abstract Background To report on relationships among baseline serum anti-Müllerian hormone (AMH) measurements, blastocyst development and other selected embryology parameters observed in non-donor oocyte IVF cycles. Methods Pre-treatment AMH was measured in patients undergoing IVF (n = 79) and retrospectively correlated to in vitro embryo development noted during culture. Results Mean (+\\/- SD) age for study patients in this study group was 36.3 ± 4.0 (range = 28-45) yrs, and mean (+\\/- SD) terminal serum estradiol during IVF was 5929 +\\/- 4056 pmol\\/l. A moderate positive correlation (0.49; 95% CI 0.31 to 0.65) was noted between basal serum AMH and number of MII oocytes retrieved. Similarly, a moderate positive correlation (0.44) was observed between serum AMH and number of early cleavage-stage embryos (95% CI 0.24 to 0.61), suggesting a relationship between serum AMH and embryo development in IVF. Of note, serum AMH levels at baseline were significantly different for patients who did and did not undergo blastocyst transfer (15.6 vs. 10.9 pmol\\/l; p = 0.029). Conclusions While serum AMH has found increasing application as a predictor of ovarian reserve for patients prior to IVF, its roles to estimate in vitro embryo morphology and potential to advance to blastocyst stage have not been extensively investigated. These data suggest that baseline serum AMH determinations can help forecast blastocyst developmental during IVF. Serum AMH measured before treatment may assist patients, clinicians and embryologists as scheduling of embryo transfer is outlined. Additional studies are needed to confirm these correlations and to better define the role of baseline serum AMH level in the prediction of blastocyst formation.

  11. Serum measurement of muscle and oxidative damage in soccer players after a game

    Directory of Open Access Journals (Sweden)

    Cleber Aurino de Pinho

    2010-06-01

    Full Text Available Futsal is a sport that requires sudden acceleration and deceleration with abruptchanges in direction. The marked impacts experienced by futsal players lead to muscle andoxidative damage. The objective of this study was to evaluate the serum levels of markers ofmuscle and oxidative damage in futsal players after a game. Six players with a mean age of 21.2± 0.98 years, weight of 67.1 ± 5.5 kg and height of 171.0 ± 0.07 cm participated in this study.Measurements were obtained 30 minutes before game 1 (pre-game, immediately after game 1(post-game 1, and immediately after a second game (post-game 2, which was performed 24hours after game 1. Serum was collected for the evaluation of creatine kinase and of damageto proteins and lipids. Creatine kinase concentrations, lipid peroxidation (xylenol and proteincarbonylation were significantly higher after games 1 and 2 when compared to pre-game values.Sulfhydryl levels were lower after the end of games 1 and 2 compared to pre-game values. Nodifference in any of the parameters analyzed was observed between post-game 1 and post-game2. Taken together, the results demonstrate that a futsal match provokes muscle and oxidativedamage. Surprisingly, no increase in the parameters studied was observed after game 2. In viewof the limited knowledge about the time of recovery after a futsal match, this study may provideimportant information to professionals working with this sport.

  12. Solid Phase Radioimmunoassay for Measuring Serum Prolactin Using Antibody Coupled Magnetizable Particles

    International Nuclear Information System (INIS)

    El-Bayoumy, A.S.A.

    2012-01-01

    The objective of the present work was to prepare solid phase radioimmunoassay (RIA) reagents. Development as well as optimization and validation of RIA system using solid phase magnetic particles for the measurement of prolactin (PRL) in human serum are described. The production of polyclonal antibodies was carried out by immunizing three Balb/C mice intraperitoneal through primary injection and two booster doses. Low density magnetizable cellulose iron oxide particles have been used to couple covalently to the IgG fraction of polyclonal anti-prolactin using carbonyl diimidazole activation method and applied as a solid phase separating agent for RIA of serum prolactin. Preparation of 125 I-PRL tracer was prepared using lactoperoxidase method and it was purified by gel filtration using sephadex G-100. The PRL standards were prepared using a highly purified PRL antigen with assay buffer as standard matrix. Optimization and validation of the assay were carried out. The results obtained provide a low cost, simple, sensitive, specific and accurate RIA system of prolactin based on magnetizable solid phase separation. These magnetic particles retain their characteristics during storage for 6 months at 4 degree C. In conclusion, this assay could be used as a useful diagnostic tool for pituitary dysfunction and possible reproductive disability.

  13. Study on the measurement of serum thymidine kinase and its clinical significance in hematological neoplastic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Torizumi, Kazutami; Aibata, Hirofumi; Yamada, Ryusaku; Shimizu, Eiji; Okamoto, Yukiharu; Tsujimoto, Masato; Tsuda, Tadaaki; Ota, Kiichiro

    1988-06-01

    A 'Prolifigen TK-REA' kit for measuring serum thymidine kinase (TK) was fundamentally and clinically evaluated. Laboratory findings for recovery, dilution, and reproducibility were satisfactory. There was no correlation between serum TK activity and serum lactic dehydrogenase, carcinoembryonic antigen, or ..cap alpha..-fetoprotein. The serum concentration of TK in normal volunteers ranged from 1.6 to 6.5 U/L. It was extremely high for chronic myeloid leukemia (CML) and acute myeloid leukemia (AML), as compared to the normal value. In the AML group, higher incidence of blasts in peripheral blood tended to be associated with higher serum concentration of TK. A similar tendency was seen in the case of acute lymphocytic leukemia (ALL) and myelodysplasia syndrome (MDS). A positive correlation between serum TK activity and the absolute counts of myeloblasts in peripheral blood existed in CML and AML patients. Since patients with hematological neoplastic disorders, who have abnormality in DNA metabolism, tended to have higher serum TK activity than did normal volunteers, serum TK activity may have a potential marker for abnormal DNA metabolism. (Namekawa, K.).

  14. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  15. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    International Nuclear Information System (INIS)

    Schuettler, J.; White, P.F.

    1984-01-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories

  16. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, J.; White, P.F.

    1984-09-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.

  17. Correlation between measured energy expenditure and clinically obtained variables in trauma and sepsis patients.

    Science.gov (United States)

    Frankenfield, D C; Omert, L A; Badellino, M M; Wiles, C E; Bagley, S M; Goodarzi, S; Siegel, J H

    1994-01-01

    Indirect calorimetry is the preferred method for determining caloric requirements of patients, but availability of the device is limited by high cost. A study was therefore conducted to determine whether clinically obtainable variables could be used to predict metabolic rate. Patients with severe trauma or sepsis who required mechanical ventilation were measured by an open-circuit indirect calorimeter. Several clinical variables were obtained simultaneously. Measurements were repeated every 12 hours for up to 10 days. Twenty-six trauma and 30 sepsis patients were measured 423 times. Mean resting energy expenditure was 36 +/- 7 kcal/kg (trauma) vs 45 +/- 8 kcal/kg (sepsis) (p types.

  18. Serum adipokines, adipose tissue measurements and metabolic parameters in patients with advanced radiographic knee osteoarthritis.

    Science.gov (United States)

    Toussirot, Eric; Michel, Fabrice; Béreau, Matthieu; Dehecq, Barbara; Gaugler, Béatrice; Wendling, Daniel; Grandclément, Emilie; Saas, Philippe; Dumoulin, Gilles

    2017-11-01

    We conducted the present study to evaluate the serum levels of adipokines (leptin, total and high molecular adiponectin, resistin), a marker of cartilage breakdown (C2C), and ghrelin together with body composition in patients with knee osteoarthritis (OA). Fifty patients and 50 sex-matched healthy subjects (HS) were evaluated. Knee OA was scored according to the Kellgren-Lawrence (KL) grade. Body composition parameters including lean mass and measurements of fat mass (total fat, adiposity, fat in the android and gynoid regions, visceral fat and trunk/legs fat ratio) were obtained using dual energy X-ray absorptiometry. Most of the recruited patients (88%) had advanced knee OA with KL grade 3 or 4. The patients had higher body mass index than HS (p < 0.0001). Serum leptin, high molecular adiponectin, resistin and ghrelin levels did not differ between patients and HS. Total adiponectin was higher in women with OA compared to women from the HS group (p = 0.004). Total fat mass, adiposity and measurements of central adiposity (fat in the android region, trunk/lower limbs fat ratio and visceral fat) were increased in patients with knee OA (all p < 0.05). Total adiponectin was borderline associated with the severity of OA. Our results show that total adiponectin is significantly increased in women with advanced knee OA. Independently of gender, patients with severe knee OA were characterized by a significant excess of fat with a distribution toward the visceral region. This abnormal body composition may contribute to the cardiometabolic profile that is described in patients with knee OA.

  19. Serum and urinary oestrone sulphate in pregnancy and delivery measured by a direct radioimmunoassay

    International Nuclear Information System (INIS)

    Honjo, Hideo; Kitawaki, Jo; Itoh, Masafumi; Yasuda, Jinsuke; Yamamoto, Takara; Yamamoto, Takao; Okada, Hiroji; Ohkubo, Tadashi; Nambara, Toshio

    1986-01-01

    Serum and urinary levels of oestrone sulphate in pregnancy and delivery were measured by a direct radioimmunoassay without hydrolysis. the serum and urinary oestrone sulphate increased as pregnancy progressed. the mean level of serum oestrone sulphate increased to the highest peak of 494 pmol/ml at the 35th gestational week and then decreased. The mean level of urinary oestrone sulphate increased to the highest peak of 1.28 μmol/l at the 34th gestational week and the decreased. At vaginal deliveries, the mean level of maternal peripheral serum oestrone sulphate increased hourly at as high a level as 979 pmol/ml. The mean serum level of oestrone sulphate was 204 pmol/ml in the umbilical artery and 145 pmol/ml in the umbilical vein. At Caesarean section, on the other hand, the maternal peripheral serum level of oestrone sulphate averaged 362 pmol/ml. The mean serum levels of oestrone sulphate wre 90.7 pmol/ml and 171 pmol/ml in the umbilical artery and umbilical vein, respectively. These results suggest a maternal origin of oestrone sulphate in pregnancy, with fluctuations in the levels being of interest in relation to labour pain. (author)

  20. Measurement of serum type III procollagen aminopeptide with RIA-gnost PIIIP coated tube

    International Nuclear Information System (INIS)

    Maruyama, Katsuya; Takagi, Toshikazu; Okazaki, Isao

    1992-01-01

    In 55 patients with various alcoholic liver diseases, serum type III procollagen aminopeptide (PIIIP) was measured on admission, on biopsy (2-4 weeks after admission) and on discharge from hospital (3 months after admission) using RIA-gnost PIIIP coated tube, an assay kit recently launched by Hoechst Japan Limited. Serum PIIIP on admission showed a good correlation with the degree of hepatic fibrosis and was significantly higher in any disease group than in healthy controls, suggesting its usefulness as an indicator of hepatic fibrosis. After abstinence, however, serum PIIIP level exhibited an increasing tendency in all the disease groups expect alcoholic hepatitis, and the number of laboratory tests showing a significant correlation with PIIIP decreased as compared with that on admission. The mechanism of serum PIIIP elevations seen after abstience is yet to be elucidated in detail, considering their possible association with factors other than collagen synthesis in the liver. (author)

  1. Magnetic susceptibility measurements of boring cores obtained from regional hydrological study project

    International Nuclear Information System (INIS)

    Hasegawa, Ken

    2010-02-01

    We measured the magnetic susceptibility of boring cores obtained from the Regional Hydrological Study Project to interpret the aeromagnetic survey data which was carried out in Tono area with about 40km square surrounding Tono Geoscience Center. The result of measurements indicates that the magnetic susceptibility of the Toki Granite is not distributed uniformly and the maximum value becomes two orders in magnitude larger than its minimum value. (author)

  2. Proposal of a candidate international conventional reference measurement procedure for free thyroxine in serum.

    NARCIS (Netherlands)

    Thienpont, L.M.; Beastall, G.H.; Christofides, N.D.; Faix, J.D.; Ieiri, T.; Jarrige, V.; Miller, W.G.; Miller, R.; Nelson, J.C.; Ronin, C.; Ross, H.A.; Rottmann, M.; Thijssen, J.H.; Toussaint, B.

    2007-01-01

    In the present paper the IFCC WG-STFT recommends and provides the rationale to establish metrological traceability of serum free thyroxine (FT4) measurements to a candidate international conventional reference measurement procedure. It is proposed that this procedure be based on equilibrium dialysis

  3. Analysis of the results obtained by optical measurements in plasma focus equipments

    International Nuclear Information System (INIS)

    Bilbao, L.; Bruzzone, H.

    1982-01-01

    The results obtained by shadow and Schlieren photographies and interferometry in a 1MJ plasma focus device of Frascati (CNEN-EURATOM, Italy) are compared with a great number of similar measurement results in several devices of the world. A critical analysis of the above results is presented. (L.C.) [pt

  4. Clinical applications of measurement of serum immunoreactive levels of erythropoietin

    International Nuclear Information System (INIS)

    Miller, M.E.; Chandra, M.; Garcia, J.F.

    1985-01-01

    The purification of erythropoietin (Ep) in 1977 enabled investigators to more clearly define the role of this hormone in erythropoiesis in man. Radioimmunoassays were rapidly developed. Undoubtedly differences between levels of immunoreactive and biologically active Ep will be found but the resolution of these discrepancies will expand our understanding of the erythron. Recently others described a monoclonal antibody against Ep. Because of this breakthrough, large quantities of pure hormone should soon be available to a larger number of investigators than currently have access to it. The major clinical use of this hormone will probably be in the treatment of the anemia of chronic renal disease. In the relatively few years since the radioimmunoassay (RIA) was developed, measurements of the levels of this hormone have been made in several disease states as well as in normal man. Most of the findings to date confirm the predictions that have been made over the years based on studies done using the rather crude bioassay for Ep. In the present study the authors shall review and expand on what is known about subjects with chronic lung and renal disease

  5. Development of a quick serum IL-6 measuring system in rheumatoid arthritis.

    Science.gov (United States)

    Koyama, Kensuke; Ohba, Tetsuro; Ishii, Kentaro; Jung, Giman; Haro, Hirotaka; Matsuda, Kenichi

    2017-07-01

    Interleukin-6 (IL-6) plays a crucial role in the pathogenesis of rheumatoid arthritis (RA). Both fulfillment of remission criteria and assessment of other methods of evaluation of RA are important for preventing joint damage progression. Measurement of serum IL-6 concentrations has been reported to be useful for monitoring RA disease activity. However, it takes at least 4-5h to measure serum IL-6 concentrations using traditional methods, which limits its utility during routine assessment in daily clinical practice settings. We established a novel method that enables measurement of serum IL-6 within 24min and requires a very small blood volume. We investigated the accuracy and efficacy of this system in RA patients. One hundred fifty blood samples collected from 76 patients were measured using the two systems. We first developed the prototype of the Human IL-6 RAYFAST. Then, we examined the correlation between the prototype RAYFAST and chemiluminescent enzyme immunoassay (CLEIA) methods. Finally, we compared IL-6 concentrations and clinical parameters using both systems. The correlation between RAYFAST (x) and CLEIA (y) for IL-6 was y=0.895x-5.94, r=0.941 (p<0.0001). Serum IL-6 concentrations in RAYFAST correlated with DAS28-CRP (r=0.372, p<0.05) and DAS28-ESR (r=0.397, p<0.01). Serum IL-6 concentrations in CLEIA correlated with DAS28-CRP (r=0.313, p<0.001) and DAS28-ESR (r=0.353, p<0.001). This new cytokine quick measure system is as accurate as CLEIA methods. Serum IL-6 concentrations can be measured in 24min using the prototype RAYFAST. It might be usable in the daily clinical practice setting, thereby contributing to improved RA management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

    Directory of Open Access Journals (Sweden)

    Mehmet Kola

    2014-01-01

    Full Text Available Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ. Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC. Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2 and reproducibility (ICC, 0.916-0.999 were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2 and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all. Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

  7. Validation of self-reported smoking status by measuring serum cotinine levels: an Indian perspective.

    Science.gov (United States)

    Jeemon, P; Agarwal, S; Ramakrishnan, L; Gupta, R; Snehi, U; Chaturvedi, V; Reddy, K S; Prabhakaran, D

    2010-01-01

    Serum cotinine levels are a reliable marker of tobacco use. Few studies have validated questionnaires assessing smoking and exposure to environmental tobacco smoke (ETS) against serum levels. We undertook such a study in industrial workers in India. We chose 426 individuals by stratified random sampling from a database of 3397 individuals surveyed at New Delhi for the cardiovascular disease surveillance programme in a large industrial setting. Questionnaires assessing details of smoking practices and duration of exposure to ETS (if any) were administered. Cotinine levels were measured in the blood samples of these individuals. The study population comprised 142 nonsmokers not exposed to ETS, 142 non-smokers exposed to ETS and 142 active smokers. Cotinine levels among nonsmokers not exposed to ETS were non-detectable; and for non-smokers exposed to ETS and active smokers, the median (interquartile range) levels were non-detectable (non-detectable to 46.1 ng/ml) and 336 ng/ml (204-500 ng/ml), respectively. The best combined sensitivity (91%) and specificity (87.2%) yielded a cotinine cut-off level of 40.35 ng/ml to differentiate active smokers from non-smokers not exposed to ETS and those exposed to ETS (area under the curve 0.902). The cut-off cotinine level was estimated at 10.95 ng/ml using a similar analysis (sensitivity 43%, specificity 82%; area under the curve 0.64) to distinguish non-smokers not exposed to ETS from those exposed to ETS. The misclassification rate was estimated at 19% and 57.1% among self-reported non-smokers not exposed to ETS and those exposed to ETS, respectively. Obtaining a history of tobacco use is an accurate method of detecting smokers in epidemiological studies whereas serum cotinine levels accurately differentiate smokers from non-smokers. However, a brief questionnaire assessing passive exposure to smoke has poor sensitivity in distinguishing non-smokers exposed to ETS from those not exposed to ETS.

  8. Assessment of a method for measuring serum thyroxine by radioimmunoassay, with use of polyethylene glycol precipitation

    International Nuclear Information System (INIS)

    Farid, N.R.; Kennedy, C.

    1977-01-01

    We assessed the efficacy of a new thyroxine radioimmunoassay kit (Abbott) in which polyethylene glycol is used to separate bound from free hormone. Mean serum thyroxine was 88 +- 15 (+-SD) μg/liter for 96 normal persons. Results for hypothyroid and hyperthyroid persons were clearly separated from those for normal individuals. Women taking oral contraceptive preparations showed variable increases in their serum thyroxine values. The coefficient of variation ranged from 1 to 3% within assay and from 5.4 to 11% among different assays. Excellent parallelism was demonstrated between thyroxine values estimated by this method and those obtained either by competitive protein binding or by a separate radioimmunoassay for the hormone

  9. Measurement of serum leptin levels in polycystic ovary syndrome with hyperandrogenemia and its significance

    International Nuclear Information System (INIS)

    Wang Yande; Zhang Zhiping; Lu Gen; Luo Beilei

    2002-01-01

    Objective: To investigate the serum leptin concentration in polycystic ovary syndrome (PCOS) with hyperandrogenemia (HA) and its relationship with testosterone (T) level and body mass index (BMI). Methods: Serum leptin levels were measured by radioimmunoassay in 53 patients with PCOS, in which 36 cases were of the in non-obesity group and 17 cases in obese group. 30 non-obese cases and 20 obese cases without PCOS served as controls. Results: The levels of leptin in PCOS with HA in obese and non-obese group were significantly higher than those in control group (all p < 0.01). There was a positive correlation between serum leptin levels and testosterone levels in both groups (r = 0.51, p < 0.01 and r = 0.58, p < 0.01). No correlation existed between serum leptin levels and body mass index (BMI) in PCOS patients of non-obese group but there was positive correlation in obesity group (r = 0.56, p < 0.01). Conclusion: High serum leptin levels is one of the characteristic in PCOS patients. The HA in PCOS patients is related to serum leptin levels and heavyweight or obese patients have the phenomenon of leptin resistance

  10. Accuracy of total oxidant measurement as obtained by the phenolphthalin method

    Energy Technology Data Exchange (ETDEWEB)

    Louw, C W; Halliday, E C

    1963-01-01

    The phenolphthalin method of Haagen-Smit and Brunelle (1958) was chosen for a preliminary survey of total oxidant level in Pretoria air, because of its sensitivity. Difficulty, however, was encountered in obtaining reliable standard curves. Some improvement was obtained when conducting all operations except photometer measurements at the temperature of melting ice. It was also found that when the sequence of adding the reagents was changed, so as to simulate conditions during actual sampling, a standard curve approximating a straight line and differing considerably from that of McCabe (1953) was obtained. It follows that values of total oxidant obtained by any experimentor will depend to a certain extent upon the method of standard curve preparation he uses, and when comparisons are made between measurements by experimentors in different towns or countries this factor should be taken into consideration. The accuracy (95% confidence) obtained by the phenolphthalin method, using the mean of three successive samples, was shown to be in the region of 30% for very low amounts of oxidant.

  11. Using Photogrammetric UAV Measurements as Support for Classical Topographical Measurements in Order to Obtain the Topographic Plan for Urban Areas

    Directory of Open Access Journals (Sweden)

    Elemer Emanuel SUBA

    2017-11-01

    Full Text Available This article aims to highlight the benefits of UAV photogrammetric measurements in addition to classical ones. It will also deal with the processing and integration of the point cloud, respectively the digital elevation model in topo-cadastral works. The main purpose of this paper is to compare the results obtained using the UAV photogrammetric measurements with the results obtained by classical methods. It will briefly present the classical measurements made with the total station. In the present project, the closed-circuit traverse and the supported on the endings traverse were made using known coordinate points. Determining the coordinates of the points used for the traverses was done by GNSS methods. The area on which the measurements were made is 67942m2 and is covered by 31 determined station points. From these points, 13 were used as ground control points, respectively components of the aero-triangulation network and 17 points were used to control the obtained results by comparing their coordinates obtained by classical methods with those obtained by the UAV photogrammetric method. It was intended that the constraint points of the aero triangulation to be uniformly distributed on the studied surface.

  12. Exploratory study on a statistical method to analyse time resolved data obtained during nanomaterial exposure measurements

    International Nuclear Information System (INIS)

    Clerc, F; Njiki-Menga, G-H; Witschger, O

    2013-01-01

    Most of the measurement strategies that are suggested at the international level to assess workplace exposure to nanomaterials rely on devices measuring, in real time, airborne particles concentrations (according different metrics). Since none of the instruments to measure aerosols can distinguish a particle of interest to the background aerosol, the statistical analysis of time resolved data requires special attention. So far, very few approaches have been used for statistical analysis in the literature. This ranges from simple qualitative analysis of graphs to the implementation of more complex statistical models. To date, there is still no consensus on a particular approach and the current period is always looking for an appropriate and robust method. In this context, this exploratory study investigates a statistical method to analyse time resolved data based on a Bayesian probabilistic approach. To investigate and illustrate the use of the this statistical method, particle number concentration data from a workplace study that investigated the potential for exposure via inhalation from cleanout operations by sandpapering of a reactor producing nanocomposite thin films have been used. In this workplace study, the background issue has been addressed through the near-field and far-field approaches and several size integrated and time resolved devices have been used. The analysis of the results presented here focuses only on data obtained with two handheld condensation particle counters. While one was measuring at the source of the released particles, the other one was measuring in parallel far-field. The Bayesian probabilistic approach allows a probabilistic modelling of data series, and the observed task is modelled in the form of probability distributions. The probability distributions issuing from time resolved data obtained at the source can be compared with the probability distributions issuing from the time resolved data obtained far-field, leading in a

  13. The measurement of serum human parathyroid hormone (h-PTH53-84) and effect of exercise on calcium metabolism

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Taniguchi, Yoshiyuki; Aibata, Hirofumi; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    This study was focussed our attention on the measurement within the upper physiological level of human serum parathyroid hormone (PTH), using kits of human PTH 53 - 84. This assay kit was able to detect serum PTH in sera with suble changes of serum calcium concentrations before and after short term exercise. These serum PTH levels before and after exercise seemed to be changed within the upper physiological levels of PTH. Thus, this study suggested that the assay kit was likely to become a useful tool of the measurement of the physiological level of serum PTH in humans. (author)

  14. Clinical review: improving the measurement of serum thyroglobulin with mass spectrometry.

    Science.gov (United States)

    Hoofnagle, Andrew N; Roth, Mara Y

    2013-04-01

    Serum thyroglobulin (Tg) measurements are central to the management of patients treated for differentiated thyroid carcinoma. For decades, Tg measurements have relied on methods that are subject to interference by commonly found substances in human serum and plasma, such as Tg autoantibodies. As a result, many patients need additional imaging studies to rule out cancer persistence or recurrence that could be avoided with more sensitive and specific testing methods. The aims of this review are to: 1) briefly review the interferences common to Tg immunoassays; 2) introduce readers to liquid chromatography-tandem mass spectrometry as a method for quantifying proteins in human serum/plasma; and 3) discuss the potential benefits and limitations of the method in the quantification of serum Tg. Mass spectrometric methods have traditionally lacked the sensitivity, robustness, and throughput to be useful clinical assays. These methods failed to meet the necessary clinical benchmarks due to the nature of the mass spectrometry workflow and instrumentation. Over the past few years, there have been major advances in reagents, automation, and instrumentation for the quantification of proteins using mass spectrometry. More recently, methods using mass spectrometry to detect and quantify Tg have been developed and are of sufficient quality to be used in the management of patients. Novel serum Tg assays that use mass spectrometry may avoid the issue of autoantibody interference and other problems with currently available immunoassays for Tg. Prospective studies are needed to fully understand the potential benefits of novel Tg assays to patients and care providers.

  15. An Optimal Estimation Method to Obtain Surface Layer Turbulent Fluxes from Profile Measurements

    Science.gov (United States)

    Kang, D.

    2015-12-01

    In the absence of direct turbulence measurements, the turbulence characteristics of the atmospheric surface layer are often derived from measurements of the surface layer mean properties based on Monin-Obukhov Similarity Theory (MOST). This approach requires two levels of the ensemble mean wind, temperature, and water vapor, from which the fluxes of momentum, sensible heat, and water vapor can be obtained. When only one measurement level is available, the roughness heights and the assumed properties of the corresponding variables at the respective roughness heights are used. In practice, the temporal mean with large number of samples are used in place of the ensemble mean. However, in many situations the samples of data are taken from multiple levels. It is thus desirable to derive the boundary layer flux properties using all measurements. In this study, we used an optimal estimation approach to derive surface layer properties based on all available measurements. This approach assumes that the samples are taken from a population whose ensemble mean profile follows the MOST. An optimized estimate is obtained when the results yield a minimum cost function defined as a weighted summation of all error variance at each sample altitude. The weights are based one sample data variance and the altitude of the measurements. This method was applied to measurements in the marine atmospheric surface layer from a small boat using radiosonde on a tethered balloon where temperature and relative humidity profiles in the lowest 50 m were made repeatedly in about 30 minutes. We will present the resultant fluxes and the derived MOST mean profiles using different sets of measurements. The advantage of this method over the 'traditional' methods will be illustrated. Some limitations of this optimization method will also be discussed. Its application to quantify the effects of marine surface layer environment on radar and communication signal propagation will be shown as well.

  16. Clinical evaluation of analytical variations in serum creatinine measurements : why laboratories should abandon Jaffe techniques

    NARCIS (Netherlands)

    Drion, Iefke; Cobbaert, Christa; Groenier, Klaas H.; Weykamp, Cas; Bilo, Henk J. G.; Wetzels, Jack F. M.; Kleefstra, Nanne

    2012-01-01

    Background: Non-equivalence in serum creatinine (SCr) measurements across Dutch laboratories and the consequences hereof on chronic kidney disease (CKD) staging were examined. Methods: National data from the Dutch annual external quality organization of 2009 were used. 144 participating laboratories

  17. Data analysis of solar potential in northern Bulgaria obtained by measurements with tall meteorological masts

    International Nuclear Information System (INIS)

    Terziev, A.; Genovski, I.; Petrov, P.; Valchev, V.

    2010-01-01

    Energy from the sun as a renewable energy source could be used for producing not only heat energy but also electricity. The maximum utilization of this type energy requires very good knowledge of the solar radiation for an exact geographical location. Determination of the solar intensity is carried out with special devices called pyranometers. This work considers solar potential data analysis based on data collected from meteorological masts installed in Northern Bulgaria. Comparison between the data from on-site measurements and some long-term data sources well known in literature is also considered. The possibility of studying the interpolation between the points where measurements are carried out in order to obtain solar radiation intensity Filed for the area limited by the points of measurement is also reviewed. Based on correlation analysis results the estimated energy production within the studied area has been calculated. (authors)

  18. Quantitative estimation of defects from measurement obtained by remote field eddy current inspection

    International Nuclear Information System (INIS)

    Davoust, M.E.; Fleury, G.

    1999-01-01

    Remote field eddy current technique is used for dimensioning grooves that may occurs in ferromagnetic pipes. This paper proposes a method to estimate the depth and the length of corrosion grooves from measurement of a pick-up coil signal phase at different positions close to the defect. Grooves dimensioning needs the knowledge of the physical relation between measurements and defect dimensions. So, finite element calculations are performed to obtain a parametric algebraic function of the physical phenomena. By means of this model and a previously defined general approach, an estimate of groove size may be given. In this approach, algebraic function parameters and groove dimensions are linked through a polynomial function. In order to validate this estimation procedure, a statistical study has been performed. The approach is proved to be suitable for real measurements. (authors)

  19. Difficulty in obtaining peak expiratory flow measurements in children with acute asthma.

    Science.gov (United States)

    Gorelick, Marc H; Stevens, Molly W; Schultz, Theresa; Scribano, Philip V

    2004-01-01

    To determine the frequency with which children >or=6 years with acute asthma can perform peak expiratory flow rate measurements (PEFR) in an emergency department (ED). Data were obtained from a prospective cohort study of children with acute asthma. All children (age 2-18 years old) treated in an urban pediatric ED for an acute exacerbation during randomly selected days over a 12-month period were prospectively evaluated. According to treatment protocols, PEFR was to be measured in all children age 6 years and older before therapy and after each treatment with inhaled bronchodilators. Registered respiratory therapists obtained PEFR and evaluated whether patients were able to perform the maneuver adequately. Four hundred and fifty-six children, 6 to 18 years old (median 10 years), were enrolled; 291 (64%) had PEFR measured at least once. Of those in whom PEFR was attempted at least once, only 190 (65%) were able to perform adequately. At the start of therapy, 54% (142/262) were able to perform PEFR. Of the 120 who were unable to perform initially, 76 had another attempt at the end of the ED treatment, and 55 (72%) were still unable to perform. A total of 149 patients had attempts at PEFR both at the start and end of treatment, of these, only 71 (48%) provided valid information on both attempts. Patients unable to perform PEFR were younger (mean +/- SD = 8.7 +/- 2.8 years) than those who were able to perform successfully (11.2 +/- 3.2 years) and those with no attempts (10.0 +/- 3.4 years). Children admitted to the hospital were more likely to be unable to perform PEFR (58/126 = 46%) than those discharged from the ED (43/330 = 13%, P < 0.0001). Adequate PEFR measurements are difficult to obtain in children with acute asthma. Treatment and research protocols cannot rely exclusively on PEFR for evaluation of severity.

  20. Optimal Fasting Time before Measurement of Serum Triglyceride Levels in Healthy Volunteers.

    Science.gov (United States)

    Pongsuthana, Surapun; Tivatunsakul, Naris

    2016-02-01

    Coronary heart disease is a major public health problem. Elevated triglyceride levels are a risk factor for atherosclerosis and coronary heart disease. Food intake interferes with the measurement of serum triglyceride levels, and in previous studies, fasting for 12 hours was recommended before blood sampling. In real-world practice, long fasting times cause patient discomfort and poor compliance, and the present study was, therefore, designed to determine the appropriate fasting time prior to measuring serum triglyceride levels. To determine the appropriate fasting time before measuring serum triglyceride levels. This was a pilot study performed using healthy volunteers aged between 20 and 30 years old from November 2013 to December 2013 at Rajavithi Hospital. The first blood sample was measured in the morning after fasting over 12 hours. The subjects then took their regular breakfast, after which they fasted for 8 hours. Blood samples were taken 6 and 8 hours later and sent to the laboratory for measurement of serum triglyceride levels. 40 volunteers, of whom 25 were female, were enrolled. Their mean age was 25.9 ± 2.81 years old, and their mean weight, height, and body mass index were 61.5 ± 12.5 kg, 167.2 ± 8.3 cm and 21.84 ± 3.1 kg/m2, respectively. Mean fasting serum triglyceride level at 12 hours was 80.23 ± 36.33 mg/dl, at 6 hours it was 110.65 ± 73.45 mg/dl, and at 8 hours it was 75.62 ± 46.81 mg/dl. The group fasting for 12 hours had significantly lower serum triglyceride levels than the group fasting for 6 hours (p-value = 0.003), but no significant difference was found between the group fasting for 12 hours and the one fasting for 8 hours (p-value = 0.493). The present study showed no significant difference in triglyceride levels in patients who had fasted or 8 hours and those who had done so for 12 hours. Fasting for only 8 hours before measurement of serum triglyceride may be sufficient.

  1. Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum

    DEFF Research Database (Denmark)

    Artacho-Cordón, F; Arrebola, J P; Nielsen, O

    2017-01-01

    The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained fro...

  2. A sensitive radioimmunoassay for measurements of 3,3'- diiodothyronine in unextracted serum

    International Nuclear Information System (INIS)

    Laurberg, P.

    1978-01-01

    A radioimmunoassay for measurements of 3,3'-diiodothyronine (3,3'-T2) in unextracted serum is described. Antisera to 3,3'-T2 were produced by immunization of rabbits with 3,3'-T2 coupled to human serum albumin. Scatchard plot analysis of the chosen antiserum gave an effective equilibrium constant of 1.1x 10 11 l/mol. The 3,3'-T2 binding capacity in undiluted serum was calculated to be 9.1 mmol/m. Monolabelled ( 125 I)3,3'T2 having a specific activity of 3800 mCi/mg was synthetized from 3-monoiodothyronine. The lowest concentration of standard inducing a consistent fall in per cent bound ( 125 I)3,3'-T2 was 6.0 pmol/l (0.24fmol/tube). Triiodothyronine (T3) cross-reacted significantly in the assay. At 50% inhibition of binding of ( 125 I)3,3'-T2, the cross-reaction was 0.29% (mol/mol), but at the low physiological concentrations of T3 it amounted to approximately 1%. T3 cross-reaction was corrected for in every assay. The interference of 3,3'-T2 binding proteins in serum was precluded by adding 8-anilino-1-napthalenesulphonic acid (ANS). Mean 3,3'-T2 concentrations were 38.9 pmol/l in fourteen normal young females and 48.9 pmol/l in fifteen normal young males. When 3,3'-T2 was measured(1) in extracts of serum, (2) in assays where T3 was added to standards in amounts equivalent to those present in the samples and T3 correction omitted, and (3) using a different 3,3'-T2 antibody, similar levels of 3,3'-T2 were found in normal serum. (Auth.)

  3. Entanglement in bipartite pure states of an interacting boson gas obtained by local projective measurements

    International Nuclear Information System (INIS)

    Paraan, Francis N. C.; Korepin, Vladimir E.; Molina-Vilaplana, Javier; Bose, Sougato

    2011-01-01

    We quantify the extractable entanglement of excited states of a Lieb-Liniger gas that are obtained from coarse-grained measurements on the ground state in which the boson number in one of two complementary contiguous partitions of the gas is determined. Numerically exact results obtained from the coordinate Bethe ansatz show that the von Neumann entropy of the resulting bipartite pure state increases monotonically with the strength of repulsive interactions and saturates to the impenetrable-boson limiting value. We also present evidence indicating that the largest amount of entanglement can be extracted from the most probable projected state having half the number of bosons in a given partition. Our study points to a fundamental difference between the nature of the entanglement in free-bosonic and free-fermionic systems, with the entanglement in the former being zero after projection, while that in the latter (corresponding to the impenetrable-boson limit) being nonzero.

  4. Aircraft and ground vehicle friction measurements obtained under winter runway conditions

    Science.gov (United States)

    Yager, Thomas J.

    1989-01-01

    Tests with specially instrumented NASA B-737 and B-727 aircraft together with several different ground friction measuring devices have been conducted for a variety of runway surface types and wetness conditions. This effort is part of the Joint FAA/NASA Aircraft/Ground Vehicle Runway Friction Program aimed at obtaining a better understanding of aircraft ground handling performance under adverse weather conditions, and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow-, and ice-covered runway conditions is discussed together with ground vehicle friction data obtained under similar runway conditions. For the wet, compacted snow- and ice-covered runway conditions, the relationship between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, and surface contaminant-type are discussed. The test results indicate that use of properly maintained and calibrated ground vehicles for monitoring runway friction conditions should be encouraged particularly under adverse weather conditions.

  5. Variability of bronchial measurements obtained by sequential CT using two computer-based methods

    International Nuclear Information System (INIS)

    Brillet, Pierre-Yves; Fetita, Catalin I.; Mitrea, Mihai; Preteux, Francoise; Capderou, Andre; Dreuil, Serge; Simon, Jean-Marc; Grenier, Philippe A.

    2009-01-01

    This study aimed to evaluate the variability of lumen (LA) and wall area (WA) measurements obtained on two successive MDCT acquisitions using energy-driven contour estimation (EDCE) and full width at half maximum (FWHM) approaches. Both methods were applied to a database of segmental and subsegmental bronchi with LA > 4 mm 2 containing 42 bronchial segments of 10 successive slices that best matched on each acquisition. For both methods, the 95% confidence interval between repeated MDCT was between -1.59 and 1.5 mm 2 for LA, and -3.31 and 2.96 mm 2 for WA. The values of the coefficient of measurement variation (CV 10 , i.e., percentage ratio of the standard deviation obtained from the 10 successive slices to their mean value) were strongly correlated between repeated MDCT data acquisitions (r > 0.72; p 2 , whereas WA values were lower for bronchi with WA 2 ; no systematic EDCE underestimation or overestimation was observed for thicker-walled bronchi. In conclusion, variability between CT examinations and assessment techniques may impair measurements. Therefore, new parameters such as CV 10 need to be investigated to study bronchial remodeling. Finally, EDCE and FWHM are not interchangeable in longitudinal studies. (orig.)

  6. Limitations of airway dimension measurement on images obtained using multi-detector row computed tomography.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Oguma

    Full Text Available OBJECTIVES: (a To assess the effects of computed tomography (CT scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS: An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai, and the wall area percentage (WA%. To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. RESULTS: Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001, and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. CONCLUSIONS: The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner.

  7. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Robson, E-mail: robmacedo@yahoo.com [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Fernandes, Juliano Lara [Universidade Estadual de Campinas, Campinas, SP (Brazil); Andrade, Solange Souza; Rochitte, Carlos Eduardo [Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil); Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho [Universidade Potiguar, Natal, RN (Brazil); Coelho, Otávio Rizzi [Universidade Estadual de Campinas, Campinas, SP (Brazil); Diniz, Rosiane Viana Zuza [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil)

    2013-07-15

    Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age.

  8. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    International Nuclear Information System (INIS)

    Macedo, Robson; Fernandes, Juliano Lara; Andrade, Solange Souza; Rochitte, Carlos Eduardo; Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti; Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho; Coelho, Otávio Rizzi; Diniz, Rosiane Viana Zuza

    2013-01-01

    Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age

  9. A method and tool for combining differential or inclusive measurements obtained with simultaneously constrained uncertainties

    Science.gov (United States)

    Kieseler, Jan

    2017-11-01

    A method is discussed that allows combining sets of differential or inclusive measurements. It is assumed that at least one measurement was obtained with simultaneously fitting a set of nuisance parameters, representing sources of systematic uncertainties. As a result of beneficial constraints from the data all such fitted parameters are correlated among each other. The best approach for a combination of these measurements would be the maximization of a combined likelihood, for which the full fit model of each measurement and the original data are required. However, only in rare cases this information is publicly available. In absence of this information most commonly used combination methods are not able to account for these correlations between uncertainties, which can lead to severe biases as shown in this article. The method discussed here provides a solution for this problem. It relies on the public result and its covariance or Hessian, only, and is validated against the combined-likelihood approach. A dedicated software package implementing this method is also presented. It provides a text-based user interface alongside a C++ interface. The latter also interfaces to ROOT classes for simple combination of binned measurements such as differential cross sections.

  10. A method and tool for combining differential or inclusive measurements obtained with simultaneously constrained uncertainties

    Energy Technology Data Exchange (ETDEWEB)

    Kieseler, Jan [CERN, Geneva (Switzerland)

    2017-11-15

    A method is discussed that allows combining sets of differential or inclusive measurements. It is assumed that at least one measurement was obtained with simultaneously fitting a set of nuisance parameters, representing sources of systematic uncertainties. As a result of beneficial constraints from the data all such fitted parameters are correlated among each other. The best approach for a combination of these measurements would be the maximization of a combined likelihood, for which the full fit model of each measurement and the original data are required. However, only in rare cases this information is publicly available. In absence of this information most commonly used combination methods are not able to account for these correlations between uncertainties, which can lead to severe biases as shown in this article. The method discussed here provides a solution for this problem. It relies on the public result and its covariance or Hessian, only, and is validated against the combined-likelihood approach. A dedicated software package implementing this method is also presented. It provides a text-based user interface alongside a C++ interface. The latter also interfaces to ROOT classes for simple combination of binned measurements such as differential cross sections. (orig.)

  11. Blocking temperature distribution in implanted Co-Ni nanoparticles obtained by magneto-optical measurements

    Energy Technology Data Exchange (ETDEWEB)

    D' Orazio, F.; Lucari, F. E-mail: franco.lucari@aquila.infn.it; Melchiorri, M.; Julian Fernandez, C. de; Mattei, G.; Mazzoldi, P.; Sangregorio, C.; Gatteschi, D.; Fiorani, D

    2003-05-01

    Three samples of Co-Ni alloy nanoparticles with different compositions were prepared by sequential ion implantation in silica slides. Transmission electron microscopy (TEM) showed the presence of spherical nanoparticles dispersed in the matrix. Magneto-optical Kerr effect analysis identified two magnetic components attributed to superparamagnetic particles in unblocked and blocked states, respectively. Magnetic field loops were measured as a function of temperature. Blocking temperature distributions were obtained; and their comparison with the size distributions derived from TEM provided the average magnetic anisotropy of the particles.

  12. Blocking temperature distribution in implanted Co-Ni nanoparticles obtained by magneto-optical measurements

    International Nuclear Information System (INIS)

    D'Orazio, F.; Lucari, F.; Melchiorri, M.; Julian Fernandez, C. de; Mattei, G.; Mazzoldi, P.; Sangregorio, C.; Gatteschi, D.; Fiorani, D.

    2003-01-01

    Three samples of Co-Ni alloy nanoparticles with different compositions were prepared by sequential ion implantation in silica slides. Transmission electron microscopy (TEM) showed the presence of spherical nanoparticles dispersed in the matrix. Magneto-optical Kerr effect analysis identified two magnetic components attributed to superparamagnetic particles in unblocked and blocked states, respectively. Magnetic field loops were measured as a function of temperature. Blocking temperature distributions were obtained; and their comparison with the size distributions derived from TEM provided the average magnetic anisotropy of the particles

  13. Measurement of HDO Products Using GC-TCD: Towards Obtaining Reliable Analytical Data

    Directory of Open Access Journals (Sweden)

    Zuas Oman

    2018-03-01

    Full Text Available This paper reported the method development and validation of a gas chromatography with thermal conductivity detector (GC-TCD method for the measurement of the gaseous products of hydrodeoxygenation (HDO. The method validation parameters include selectivity, precision (repeatability and reproducibility, accuracy, linearity, limit of detection (LoD, limit of quantitation (LoQ, and robustness. The results showed that the developed method was able to separate the target components (H2, CO2, CH4 and CO from their mixtures without any special sample treatment. The validated method was selective, precise, accurate, and robust. Application of the developed and validated GC-TCD method to the measurement of by-product components of HDO of bio-oil revealed a good performance with relative standard deviation (RSD less than 1.0% for all target components, implying that the process of method development and validation provides a trustworthy way of obtaining reliable analytical data.

  14. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  15. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  16. Comparison of VIDAS and Radioimmunoassay Methods for Measurement of Cortisol Concentration in Bovine Serum

    Directory of Open Access Journals (Sweden)

    Daniela Proverbio

    2013-01-01

    Full Text Available Radioimmunoassay (RIA is the “gold standard” method for evaluation of serum cortisol concentration. The VIDAS cortisol test is an enzyme-linked fluorescent assay designed for the MiniVidas system. The aim of this study was to compare the VIDAS method with RIA for measurement of bovine serum cortisol concentration. Cortisol concentrations were evaluated in 40 cows using both VIDAS and RIA methods, the latter as the reference method. A paired Student’s -test, Pearson’s correlation analysis, Bland-Altman plot, and Deming regression analysis were used to compare the two methods. There was no statistically significant difference between mean serum cortisol concentrations measured by VIDAS or RIA methods (. Both methods were able to detect significant differences in mean low and high cortisol concentrations ( RIA and VIDAS. The correlation coefficient was low, but a Bland-Altman plot and Deming regression analysis show neither constant nor proportional error. The VIDAS method produced slightly higher values than RIA, but the difference was small and in no case did the mean value move the normal range. Results suggest that VIDAS method is suitable for the determination of bovine serum cortisol concentration in studies of large numbers of animals.

  17. Measurement of serum FT/sub 4/ in pregnancy and binding protein abnormalities by different methods

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, H; Wenzel, K W

    1985-11-01

    In serum of pregnant women in the 3rd trimester, the majority of FT/sub 4/ methods compared in the present study yielded FT/sub 4/ concentrations in the lower parts of normal ranges or beyond the lower normal border lines. In TBG deficiency, serum FT/sub 4/ as measured by six FT/sub 4/ kits was found to be in the manufacturer-specified normal ranges and did not show clearly recognizable systematic differences between single kits or kit groups with different methodological principles. considerable kit-dependent differences of measured FT/sub 4/ were found in euthyroid patients with TBG excess; all values were, however, in the respective normal ranges. In dysalbuminemic hyperthyroxinemia, labelled analogue kits yielded falsely elevated FT/sub 4/ concentrations, while FT/sub 4/ measured by non-analogue methods was normal in agreement with the euthyroid status of the patient.

  18. Latest Developments on Obtaining Accurate Measurements with Pitot Tubes in ZPG Turbulent Boundary Layers

    Science.gov (United States)

    Nagib, Hassan; Vinuesa, Ricardo

    2013-11-01

    Ability of available Pitot tube corrections to provide accurate mean velocity profiles in ZPG boundary layers is re-examined following the recent work by Bailey et al. Measurements by Bailey et al., carried out with probes of diameters ranging from 0.2 to 1.89 mm, together with new data taken with larger diameters up to 12.82 mm, show deviations with respect to available high-quality datasets and hot-wire measurements in the same Reynolds number range. These deviations are significant in the buffer region around y+ = 30 - 40 , and lead to disagreement in the von Kármán coefficient κ extracted from profiles. New forms for shear, near-wall and turbulence corrections are proposed, highlighting the importance of the latest one. Improved agreement in mean velocity profiles is obtained with new forms, where shear and near-wall corrections contribute with around 85%, and remaining 15% of the total correction comes from turbulence correction. Finally, available algorithms to correct wall position in profile measurements of wall-bounded flows are tested, using as benchmark the corrected Pitot measurements with artificially simulated probe shifts and blockage effects. We develop a new scheme, κB - Musker, which is able to accurately locate wall position.

  19. Obtaining the Bunch Shape in a Linac from Beam Spectrum Measurements

    International Nuclear Information System (INIS)

    Bane, Karl LF

    1999-01-01

    In linacs with high single-bunch charge, and tight tolerances for energy spread and emittance growth, controlling the short-range wakefield effects becomes extremely important. The effects of the wakefields, in turn, depend on the bunch length and also on the bunch shape. It was shown in the linac of the Stanford Linear Collider (SLC), for example, that by shaping the bunch, the final rms energy spread could be greatly reduced, compared to for the standard Gaussian bunch shape[1]. Therefore, in machines with high single-bunch charge, a method of measuring bunch shape can be an important beam diagnostic. In a linac with low single-bunch charge, the longitudinal bunch shape can be obtained relatively easily from a single measurement of the beam's final energy spectrum, provided that the final to initial energy ratio is large. One merely shifts the average phase of the beam, so that it rides off-crest sufficiently to induce an energy variation that is monotonic with longitudinal position. Then, by knowing the initial and final energies, the rf wave number, and the average beam phase, one can directly map the spectrum into the bunch shape. In a linac with high single-bunch charge, however, due to the effect of the longitudinal wakefield, this method either does not work at all, or it requires such a large shift in beam phase as to become impractical. In earlier work[2],[3] it was shown that, even when wakefields are important, if one measures the final beam spectrum for two different (properly chosen) values of beam phase, then one can again obtain the bunch shape, and--as a by-product--also the form of the wakefield induced voltage; this method was then illustrated using data from the linac of the SLC. These SLC measurements, however, had been performed with the machine in a special configuration, where the current was low; in addition, the noise the data was low and the measured spectra were smooth distributions. Under normal SLC conditions, however, the currents

  20. Development of solid phase radioimmunoassay using antibody coupled magnetizable particles for measurement of progesterone in human serum

    International Nuclear Information System (INIS)

    Mehany, N.L.

    2007-01-01

    The aim of the present study was to prepare solid phase radioimmunoassay (RIA) reagents. Development as well as optimization and validation of RIA system using solid phase magnetic particles for the measurement of progesterone in human serum are described. The production of polyclonal antibodies was carried out by immunizing five white New-Zealand rabbits subcutaneously. Low density magnetizable cellulose iron oxide particles have been used to couple covalently to the IgG fraction of polyclonal anti-progesterone using carbonyl diimidazole activation method and applied as a solid phase separating agent for RIA of serum progesterone. 125 I-progesterone tracer was prepared using chloramine-T and iodogen oxidation methods and purified using high performance liquid chromatography. The progesterone standards were prepared using highly purified progesterone powder with hormone free serum as standard matrix. Optimization and validation of the assay were carried out. The results obtained provide a low cost, simple, sensitive, specific and accurate RIA system of progesterone based on magnetizable solid phase separation. This may be extremely helpful in diagnosis and proper management of ovulation during childbearing years

  1. Modeling of Production and Quality of Bioethanol Obtained from Sugarcane Fermentation Using Direct Dissolved Sugars Measurements

    Directory of Open Access Journals (Sweden)

    Borja Velazquez-Marti

    2016-04-01

    Full Text Available Bioethanol production from sugarcane represents an opportunity for urban-agricultural development in small communities of Ecuador. Despite the fact that the industry for bioethanol production from sugarcane in Brazil is fully developed, it is still considered expensive as a small rural business. In order to be able to reduce the costs of monitoring the production process, and avoid the application of expensive sensors, the aim of this research was modeling the kinetics of production of bioethanol based on direct measurements of Brix grades, instead of the concentration of alcohol, during the process of cane juice bio-fermentation with Saccharomyces cerevisiae. This avoids the application of expensive sensors that increase the investment costs. Fermentation experiments with three concentrations of yeast and two temperatures were carried out in a laboratory reactor. In each case Brix grades, amount of ethanol and alcoholic degree were measured. A mathematical model to predict the quality and production of bioethanol was developed from Brix grade measurements, obtaining an adjusted coefficient of determination of 0.97. The model was validated in a pilot plant.

  2. Effect of geometrical features various objects on the data quality obtained with measured by TLS

    Science.gov (United States)

    Pawłowicz, J. A.

    2017-08-01

    Collecting data on different building structures using Terrestrial Laser Scanning (TLS) has become in recent years a very popular due to minimize the time required to complete the task as compared to traditional methods. Technical parameters of 3D scanning devices (digitizers) are increasingly being improved, and the accuracy of the data collected allows you to play not only the geometry of an existing object in a digital image, but also enables the assessment of his condition. This is possible thanks to the digitalization of existing objects e.g., a 3D laser scanner, with which is obtained a digital data base is presented in the form of a cloud of points and by using reverse engineering. Measurements using laser scanners depends to a large extent, on the quality of the returning beam reflected from the target surface, towards the receiver. High impact on the strength and quality of the beam returning to the geometric features of the object. These properties may contribute to the emergence of some, sometimes even serious errors during scanning of various shapes. The study defined the effect of the laser beam distortion during the measurement objects with the same material but with different geometrical features on their three-dimensional imaging obtained from measurements made using TLS. We present the problem of data quality, dependent on the deflection of the beam intensity and shape of the object selected examples. The knowledge of these problems allows to obtain valuable data necessary for the implementation of digitization and the visualization of virtually any building structure made of any materials. The studies has been proven that the increase in the density of scanning does not affect the values of mean square error. The increase in the angle of incidence of the beam onto a flat surface, however, causes a decrease in the intensity of scattered radiation that reaches the receiver. The article presents an analysis of the laser beam reflected from broken at

  3. Assessment of MFLL column CO2 measurements obtained during the ACT-America field campaigns

    Science.gov (United States)

    Lin, B.; Browell, E. V.; Kooi, S. A.; Dobler, J. T.; Campbell, J.; Fan, T. F.; Pal, S.; O'Dell, C. W.; Obland, M. D.; Erxleben, W. H.; McGregor, D.; Kochanov, R. V.; DiGangi, J. P.; Davis, K. J.; Choi, Y.

    2017-12-01

    Accurate observations of atmospheric CO2 with airborne and space-based lidar systems such as those used during the Atmospheric Carbon and Transport - America (ACT-America) field campaigns and proposed for the NASA ASCENDS mission would improve our knowledge of CO2 distributions and variations on both regional and global scales, reduce the uncertainties in atmospheric CO2 transport and fluxes, and increase confidence in predictions of future climate changes. To reach these scientific goals, atmospheric column CO2 (XCO2) measurements of the Harris Corporation's Multifunctional Fiber Laser Lidar (MFLL) obtained during the first two ACT-America flight campaigns have been thoroughly investigated by the ACT-America lidar measurement group. MFLL is an intensity-modulated continuous-wave lidar operating in the 1.57-mm CO2 absorption band. Atmospheric XCO2 amounts are retrieved based on the integrated path differential absorption of the lidar signals at online and offline wavelengths between the aircraft and the ground. NASA Langley Research Center and Harris have been collaborating in the development and evaluation of this CO2 lidar approach for a number of years. To gain insights into the lidar performance, the measurement group has collected all possible lidar measurements with corresponding in-situ atmospheric profile information from the first two ACT-America field campaigns, including the data from several flight legs dedicated to lidar calibration. Initially large differences (-1 to 2 %) were found between lidar measured CO2 optical depths and those derived from in-situ observations and spectroscopy from HITRAN2008. When an improved spectroscopic model (Pre-HITRAN2016) was applied, the large systematic errors were much more consistent leading to the development of an empirical linear correction of measured optical depth based on the calibration flight data. This correction accounts for remaining uncertainties in spectroscopic models, environmental conditions, such as

  4. Measurements of vitamin B12 in human blood serum using resonance Raman spectroscopy

    Science.gov (United States)

    Tsiminis, G.; Schartner, E. P.; Brooks, J. L.; Hutchinson, M. R.

    2016-12-01

    Vitamin B12 (cobalamin and its derivatives) deficiency has been identified as a potential modifiable risk factor for dementia and Alzheimer's disease. Chronic deficiency of vitamin B12 has been significantly associated with an increased risk of cognitive decline. An effective and efficient method for measuring vitamin B12 concentration in human blood would enable ongoing tracking and assessment of this potential modifiable risk factor. In this work we present an optical sensor based on resonance Raman spectroscopy for rapid measurements of vitamin B12 in human blood serum. The measurement takes less than a minute and requires minimum preparation (centrifuging) of the collected blood samples.

  5. The correlation between superparamagnetic blocking temperatures and peak temperatures obtained from ac magnetization measurements

    International Nuclear Information System (INIS)

    Madsen, Daniel Esmarch; Moerup, Steen; Hansen, Mikkel Fougt

    2008-01-01

    We study the correlation between the superparamagnetic blocking temperature T B and the peak positions T p observed in ac magnetization measurements for nanoparticles of different classes of magnetic materials. In general, T p = α+βT B . The parameters α and β are different for the in-phase (χ') and out-of-phase (χ'') components and depend on the width σ V of the log-normal volume distribution and the class of magnetic material (ferromagnetic/antiferromagnetic). Consequently, knowledge of both α and β is required if the anisotropy energy barrier KV and the attempt time τ 0 are to be reliably obtained from an analysis based solely on the peak positions

  6. Reliable clinical serum analysis with reusable electrochemical sensor: Toward point-of-care measurement of the antipsychotic medication clozapine.

    Science.gov (United States)

    Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F

    2017-09-15

    Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Evaluation of automated assays for immunoglobulin G, M, and A measurements in dog and cat serum.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Caldin, Marco; Tecles, Fernando; Ceron, Jose J

    2013-09-01

    Measurements of immunoglobulins (Igs) in companion animals can be useful to detect deficiencies of the humoral immune system, that can be associated with opportunistic or chronic infections, or other immune-mediated disorders including B-cell neoplasms. The purpose of this study was to evaluate commercially available automated immunoturbidimetric assays designed for human IgG, M, and A measurements in canine and feline serum using species-specific calibrators. Canine and feline serum samples with different IgG, M, and A concentrations were used for the analytical validation of the assays. Intra- and inter-assay precision, linearity under dilution, spiking recovery, and limit of detection were determined. In addition, effects of lipemia, hemolysis, and bilirubinemia were evaluated. Finally, Ig concentrations were determined in small groups of diseased dogs and cats, and compared with healthy groups. Spiking recovery and linearity under dilution tests showed that the assays measured Igs in canine and feline serum samples precisely and accurately. Intra- and inter-assay imprecisions were lower than 15% in all cases. Significantly higher IgG, IgM, and IgA levels were observed in dogs with leishmaniasis, while dogs with pyometra showed a statistically significant increase in IgM and IgA concentrations in comparison with healthy dogs. Significantly higher IgG and IgM levels were observed in FIV-infected cats compared with healthy ones. The automated human Ig assays showed adequate precision and accuracy with serum samples from dogs and cats. Also, they were able to discriminate different concentrations of Igs in healthy and diseased animals. © 2013 American Society for Veterinary Clinical Pathology.

  8. Clinical usefulness of serum free light chains measurement in patients with multiple myeloma: comparative analysis of two different tests

    Directory of Open Access Journals (Sweden)

    Tadeusz Kubicki

    2017-01-01

    Full Text Available Introduction: There are two commercially available tests for measurement of serum free light chains (sFLC in multiple myeloma (MM patients – Freelite and N Latex FLC. The aim of this study was to perform an assessment and direct comparison of the usefulness of the methods in routine clinical practice.Methods: 40 refractory/relapsed MM patients underwent routine disease activity assessment studies, along with sFLC analysis using both assays. Correlation and concordance between the tests and sensitivity of studied methods of sFLC assessment were established. Special attention was focused on sFLC results in patients finally evaluated after completing the treatment. Results: A weak correlation for the measurement of both κ [Passing–Bablok slope (PB = 0.7681] and λ chains [(PB = 1.542] was found. Using Bland–Altman plots, a bias of 0.0467 (κ and -0.2133 (λ between the measurements was documented. The concordance coefficient equaled 0.87 for κ, 0.62 for λ and 0.52 for κ/λ ratio. Ten patients had an abnormal Freelite assay κ/λ ratio and normal N Latex FLC κ/λ ratio. Three of these patients had negative serum protein electrophoresis results and fulfilled diagnostic criteria of stringent complete remission (sCR according to N Latex FLC (but not according to Freelite. When the κ/λ ratio obtained by both methods was compared to patients’ serum/urine protein electrophoresis and immunofixation results, sensitivity of Freelite and N Latex FLC was established to be 62.5% and 41%, respectively. Conclusions: There was no strong correlation or concordance between the two assays, and the sensitivity in terms of sFLC detection was different. This may cause problems when diagnosis of sCR is considered.

  9. Discrepancy between haemagglutination and radioimmunological techniques for measurement of serum thyroglobulin autoantibodies

    Energy Technology Data Exchange (ETDEWEB)

    Feldt-Rasmussen, U; Perrild, H; Bech, K; Bliddal, H; Date, J; Hoeier Madsen, M; Nordfang, O; Ryder, L P; Thomsen, M; Kappelgaard, E [Dept. of Internal Medicine and Endocrinology, Herlev University Hospital, Dept. of Medicine E, Frederiksberg Hospital, Dept. of Clinical Chemistry, Odense University Hospital, Autoimmune Lab., Serum Institute, Tissue Typing Laboratory and Medical Dept. TA, Rigshospitalet, Copenhagen, Denmark

    1983-01-01

    Recently, it has been suggested that in some patients with autoimmune thyroid diseases the tanned red cell (TRC) method for detection of thyroglobulin autoantibodies (TgAb) is negative where TgAb measured by radioimmunoassay (RIA) show positive values. To investigate this further, patients with thyroid diseaes, pernicious anaemia and a control group were studied for serum concentrations of TgAb by TRC and by quantitative RIA, calibrated against MRC Standard A65/93. Antibodies for microsomes (MAb) were measured immunofluoretically. There was in all patient groups Hashimoto's thyroiditis (n=41), Graves' disease (n=50), Idiopathic myxoedemia (n=12), euthyroid Graves' disease (n=7), pernicious anaemia (n=81) a discrepancy between TgAb measured by TRC and RIA, respectively, whereas there was a reasonable correlation between the presence of TgAb by RIA and the presence of MAb. A possible interference from antinuclear antibodies and rheumatoid factors was ruled out. There was no increased frequency of TgAb measured by RIA in the control group. Fractionation of TRC negative sera revealed macromolecular TRC-activity, whereas TgAb positive sera by both methods had almost exclusively RIA and TRC activiy corresponding to TgG. Based on these results and others it seems that the TRC method for measurement of serum TgAb is of limited diagnostic value. Furthermore, the TRC method is in many cases not sensitive for screening fo TgAb prior to measurement of serum Tg which is of importance as this method shows false values in the presence of TgAb due to methodologial interference.

  10. Discrepancy between haemagglutination and radioimmunological techniques for measurement of serum thyroglobulin autoantibodies

    Energy Technology Data Exchange (ETDEWEB)

    Feldt-Rasmussen, U.; Perrild, H.; Bech, K.; Bliddal, H.; Date, J.; Hoeier Madsen, M.; Nordfang, O.; Ryder, L.P.; Thomsen, M.; Kappelgaard, E. (Dept. of Internal Medicine and Endocrinology, Herlev University Hospital, Dept. of Medicine E, Frederiksberg Hospital, Dept. of Clinical Chemistry, Odense University Hospital, Autoimmune Lab., Serum Institute, Tissue Typing Laboratory and Medical Dept. TA, Rigshospitalet, Copenhagen, Denmark)

    1983-01-01

    Recently, it has been suggested that in some patients with autoimmune thyroid diseases the tanned red cell (TRC) method for detection of thyroglobulin autoantibodies (TgAb) is negative where TgAb measured by radioimmunoassay (RIA) show positive values. To investigate this further, patients with thyroid diseaes, pernicious anaemia and a control group were studied for serum concentrations of TgAb by TRC and by quantitative RIA, calibrated against MRC Standard A65/93. Antibodies for microsomes (MAb) were measured immunofluoretically. There was in all patient groups Hashimoto's thyroiditis (n=41), Graves' disease (n=50), Idiopathic myxoedemia (n=12), euthyroid Graves' disease (n=7), pernicious anaemia (n=81) a discrepancy between TgAb measured by TRC and RIA, respectively, whereas there was a reasonable correlation between the presence of TgAb by RIA and the presence of MAb. A possible interference from antinuclear antibodies and rheumatoid factors was ruled out. There was no increased frequency of TgAb measured by RIA in the control group. Fractionation of TRC negative sera revealed macromolecular TRC-activity, whereas TgAb positive sera by both methods had almost exclusively RIA and TRC activiy corresponding to TgG. Based on these results and others it seems that the TRC method for measurement of serum TgAb is of limited diagnostic value. Furthermore, the TRC method is in many cases not sensitive for screening fo TgAb prior to measurement of serum Tg which is of importance as this method shows false values in the presence of TgAb due to methodologial interference.

  11. Serum cystatin C concentration measured routinely is a prognostic marker for renal disease in dogs.

    Science.gov (United States)

    Iwasa, Naoki; Takashima, Satoshi; Iwasa, Tatsuo; Iwasa, Kazuko; Suzuki, Tomomi; Kobatake, Yui; Kitagawa, Hitoshi; Nishii, Naohito

    2018-06-14

    This study examined the predictive value of serum cystatin C (Cys-C) concentration, measured during routine periodic health examinations, in the renal prognosis of dogs. A cohort of 140 dogs weighing C concentrations were measured during periodic health examinations from December 2013 to March 2016 were prospectively studied, with renal disease-related death the predicted end point. Of the 140 dogs, nine died from renal diseases during the follow-up period (539 ± 249 days). Serum Cys-C concentrations were higher in the dogs that subsequently died of renal disease than in the censored group (0.8 ± 0.25 vs. 0.3 ± 0.1 mg/dl, respectively; P C concentrations (>0.55 mg/dl) had a shorter (P C concentrations (≤0.55 mg/dl). In conclusion, high serum Cys-C concentrations in periodic health examinations in dogs <15 kg predicted poorer prognosis for renal function. Copyright © 2018. Published by Elsevier Ltd.

  12. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... into 3 groups, according to whether their cell-associated HIV DNA load was or = 2,500 DNA copies/10(6) peripheral blood mononuclear cells. Clinical progression rates differed significantly between the groups (p value independent...... of serum HIV RNA (p value. Patients heterozygous for the CCR5 delta 32 allele had significantly lower HIV DNA loads than those homozygous for the normal allele (p

  13. Clinical significance of dynamic measurements of serum and urinary TNF-α contents in patients receiving kidney transplantation

    International Nuclear Information System (INIS)

    Wu Cuihua; Xu Jun; Zhang Daojie

    2004-01-01

    Objective: To investigate the clinical significance of dynamic measurements of serum and urinary TNF-α contents in patients following kidney transplantation. Methods: Serum and urinary TNF-α contents were measured with RIA in 45 patients receiving kidney transplantation (both before and 2 day after operation) and 45 controls. In the group of 33 patients without rejection, serial dynamic measurements of serum and urinary TNF-α content were repeatedly performed on d7, d14, d21 and d28 postoperatively. Results: Serum TNF-α levels in all the patients groups were significantly higher than those in the controls (P 0.05). Urinary TNF-α levels dropped even faster and approached control values by d7. Conclusion: Continuous monitoring of post-operative serum and urinary TNF-α contents serves as an important indicator of the function of the transplanted kidney

  14. Clinical significance of measurement of serum TNF-α, T, FSH and PRL levels in male infertility

    International Nuclear Information System (INIS)

    Li Tianquan; Zhou Minglian; He Haoming

    2011-01-01

    Objective: To explore the significance of changes of serum TNF-α, T, FSH and PRL levels in male patients with infertility. Methods: Serum TNF-α, T, FSH and PRL (with RIA) were measured in 36 male patients with infertility and 35 male controls. Results: Serum T level was significantly lower in the patients than those in controls (P<0.01), while the serum TNF-α, FSH and PRL levels were significantly higher in the patients (P<0.01). Serum TNF-α level was negatively correlated with T level in the patients (r=-0.5184, P<0.01) and positively correlated with FSH, PRL levels (r=0.6184, 0.5925, P<0.01). Conclusion: Serum TNF-α, T, FSH and PRL levels were significantly changed in male with infertility and determination of which might useful for prognosis and treatment clinically. (authors)

  15. Self-adaptive Green-Ampt infiltration parameters obtained from measured moisture processes

    Directory of Open Access Journals (Sweden)

    Long Xiang

    2016-07-01

    Full Text Available The Green-Ampt (G-A infiltration model (i.e., the G-A model is often used to characterize the infiltration process in hydrology. The parameters of the G-A model are critical in applications for the prediction of infiltration and associated rainfall-runoff processes. Previous approaches to determining the G-A parameters have depended on pedotransfer functions (PTFs or estimates from experimental results, usually without providing optimum values. In this study, rainfall simulators with soil moisture measurements were used to generate rainfall in various experimental plots. Observed runoff data and soil moisture dynamic data were jointly used to yield the infiltration processes, and an improved self-adaptive method was used to optimize the G-A parameters for various types of soil under different rainfall conditions. The two G-A parameters, i.e., the effective hydraulic conductivity and the effective capillary drive at the wetting front, were determined simultaneously to describe the relationships between rainfall, runoff, and infiltration processes. Through a designed experiment, the method for determining the G-A parameters was proved to be reliable in reflecting the effects of pedologic background in G-A type infiltration cases and deriving the optimum G-A parameters. Unlike PTF methods, this approach estimates the G-A parameters directly from infiltration curves obtained from rainfall simulation experiments so that it can be used to determine site-specific parameters. This study provides a self-adaptive method of optimizing the G-A parameters through designed field experiments. The parameters derived from field-measured rainfall-infiltration processes are more reliable and applicable to hydrological models.

  16. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry.

    Science.gov (United States)

    Sacco, I C N; Picon, A P; Ribeiro, A P; Sartor, C D; Camargo-Junior, F; Macedo, D O; Mori, E T T; Monte, F; Yamate, G Y; Neves, J G; Kondo, V E; Aliberti, S

    2012-09-01

    The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.

  17. Warm magnetic measurements of MCBCs: comparison between the results obtained with the Quadrupole Industrial Magnetic Measurement and the Corrector Industrial Magnetic Measurement systems

    CERN Document Server

    Remondino, Vittorio; Catalan-Lasheras, N

    2005-01-01

    MCBCs modules are first magnetically measured at Tesla using a second-generation Corrector Industrial Magnetic Measurement (CIMM). After assembly into the SSS quadrupoles, measurements are repeated at CERN using the Quadrupole Industrial Magnetic Measurement (QIMM) system. In this note, we compare the measurements provided by the two systems. In all the 18 cases examined, the correlation found is excellent. The consistency of the results obtained indicates that both systems are effective, that modules are correctly measured by the firm personnel and that magnetic characteristics of the modules do not change during their assembly in cold masses.

  18. Measurement of total antioxidant capacity in gingival crevicular fluid and serum in dogs with periodontal disease.

    Science.gov (United States)

    Pavlica, Zlatko; Petelin, Milan; Nemec, Alenka; Erzen, Damjan; Skaleric, Uros

    2004-11-01

    To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. 41 Toy and Miniature Poodles. After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.

  19. The measurement of serum TNF-α levels in patients with lichen planus.

    Science.gov (United States)

    Akpinar Kara, Yesim

    2017-12-01

    Lichen planus is a common mucocutaneous inflammatory skin disease with a multifactorial etiology. Cytokines play a key role in lichen planus pathogenesis. This study investigates the relationship between disease severity and levels of tumor necrosis factor-α (TNF-α), which is considered a primary cytokine that initiates cytotoxicity. Serum TNF-α levels were compared between a patient group (n = 34) and a control group (n = 20). TNF-α serum levels were measured using human TNF-α Enzyme-Linked Immunosorbent Assay (ELISA) test kits, and the two groups were statistically compared to each other. Mean serum TNF-α levels were found to be significantly higher in the patient group than in the control group (p 0.005). No relationship was detected between TNF-α levels and patients' sex. It is thought that TNF-α, a proinflammatory cytokine, may play an important role in the pathogenesis of lichen planus. TNF-α may be a simple and effective predictor to illustrate the inflammatory status in patients with lichen planus.

  20. Relations between various measures of iodine intake and thyroid volume, thyroid nodularity, and serum thyroglobulin

    DEFF Research Database (Denmark)

    Rasmussen, Lone Banke; Ovesen, L.; Bulow, I.

    2002-01-01

    sought to identify, if possible, groups at risk of thyroid disease because of their food choices. Design: This cohort study included 4649 randomly selected subjects with mild-to-moderate iodine deficiency; the subjects lived in 2 cities in Denmark. Iodine intake was estimated by using a food...... some measures of iodine intake were significantly related to the prevalence of thyroid nodules. Conclusions: Even in a geographic area where mild iodine deficiency is common, a significant relation between iodine intake and thyroid volume was found. All measures of iodine intake, except iodine......Background: Iodine intake can be measured in various ways, and each method may have advantages and disadvantages. Objective: We sought to investigate the potential associations of various measures of iodine intake with thyroid volume, prevalence of thyroid nodules, and serum thyroglobulin. We also...

  1. Protein Turnover Measurements in Human Serum by Serial Immunoaffinity LC-MS/MS.

    Science.gov (United States)

    Farrokhi, Vahid; Chen, Xiaoying; Neubert, Hendrik

    2018-02-01

    The half-life of target proteins is frequently an important parameter in mechanistic pharmacokinetic and pharmacodynamic (PK/PD) modeling of biotherapeutics. Clinical studies for accurate measurement of physiologically relevant protein turnover can reduce the uncertainty in PK/PD model-based predictions, for example, of the therapeutic dose and dosing regimen in first-in-human clinical trials. We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment ofmultiple human serum proteins from a [5,5,5- 2 H 3 ]-L-leucine tracer pulse-chase study in healthy volunteers. To confirm the reproducibility of turnover measurements from serial immunoaffinity enrichment, multiple aliquots from the same sample set were subjected to protein turnover analysis in varying order. Tracer incorporation was measured by multiple-reaction-monitoring mass spectrometry and target turnover was calculated using a four-compartment pharmacokinetic model. Five proteins of clinical or therapeutic relevance including soluble tumor necrosis factor receptor superfamily member 12A, tissue factor pathway inhibitor, soluble interleukin 1 receptor like 1, soluble mucosal addressin cell adhesion molecule 1, and muscle-specific creatine kinase were sequentially subjected to turnover analysis from the same human serum sample. Calculated half-lives ranged from 5-15 h; however, no tracer incorporation was observed for mucosal addressin cell adhesion molecule 1. The utility of clinical pulse-chase studies to investigate protein turnover can be extended by serial immunoaffinity enrichment of target proteins. Turnover analysis from serum and subsequently from remaining supernatants provided analytical sensitivity and reproducibility for multiple human target proteins in the same sample set, irrespective of the order of analysis. © 2017 American Association for Clinical Chemistry.

  2. Prognostic value of repeated serum CA 125 measurements in first trimester pregnancy.

    Science.gov (United States)

    Schmidt, T; Rein, D T; Foth, D; Eibach, H W; Kurbacher, C M; Mallmann, P; Römer, T

    2001-08-01

    To assess the diagnostic value of maternal CA 125 in patients with symptomatic first trimester pregnancy and to evaluate the prognostic significance of CA 125 versus beta-hCG in early pregnancies with intact fetal heartbeat, complicated by vaginal bleeding. Two prospective open-label studies with longitudinal follow-up in the second trial. Academic Department of Obstetrics and Gynecology, University of Cologne. Study 1: 168 patients presenting between gestational weeks 6 and 12 with: extrauterine pregnancy, 29; missed abortion, 50; incomplete spontaneous abortion, 38; imminent abortion, 33; and normal pregnancy (no history of endometriosis or ovarian mass), 18. Study 2: Fifty consecutive patients with vaginal bleeding during gestational weeks 6-12 all of whom having demostrable fetal heartbeat. Eighteen patients finally aborted whereas the remainder had normally continuing pregnancy until term. Study 1: Single serum determinations of CA 125 and beta-hCG were correlated with the different disorders observed. Study 2: Two sequential measurements of serum CA 125 and beta-hCG performed within a 5-7 days interval were related to the outcome of pregnancy as indicated by changes of the ultrasound presentation, miscarriage, future hospitalization, or delivery. Study 1: Patients with vaginal bleeding generally had higher median CA 125 values (38 IU/ml; range 1.3-540) compared to non-bleeding patients (17.8 IU/ml; range 1.0-157). No statistically significant differences in regard to median serum CA 125 levels between symptomatic and normal pregnancies occurred: normal pregnancy, 25.5 IU/ml (range 3.2-97); ectopic pregnancy, 26 IU/ml (range 1.3-157); missed abortion, 19.1IU/ml (range 1-242); threatened abortion, 48 IU/ml (range 5.2-540); spontaneous abortion, 40 IU/ml (range 5.4-442). Study 2: Initial CA 125 levels did not differ significantly between both groups of patients with 27/32 non-aborters and 13/18 aborters showing concentrations below 65 IU/ml. After 5-7 days, CA

  3. Development of an electrothermal atomization laser-excited atomic fluorescence spectrometry procedure for direct measurements of arsenic in diluted serum.

    Science.gov (United States)

    Swart, D J; Simeonsson, J B

    1999-11-01

    A procedure for the direct determination of arsenic in diluted serum by electrothermal atomization laser-excited atomic fluorescence spectrometry (ETA-LEAFS) is reported. Laser radiation needed to excite As at 193.696 and 197.197 nm is generated as the second anti-Stokes stimulated Raman scattering output of a frequency-doubled dye laser operating near 230.5 and 235.5 nm, respectively. Two different LEAFS schemes have been utilized and provide limits of detection of 200-300 fg for As in aqueous standards. When measurements of serum samples diluted 1:10 with deionized water are performed, a stable background signal is observed that can be accounted for by taking measurements with the laser tuned off-wavelength. No As is detected in any of the bovine or human serum samples analyzed. Measurements of 100 pg/mL standard additions of As to a diluted bovine serum sample utilizing either inorganic or organic As species demonstrate a linear relationship of the fluorescence signal to As spike concentration, but exhibit a sensitivity of approximately half that observed in pure aqueous standards. The limit of detection for As in 1:10 diluted serum samples is 65 pg/mL or 650 fg absolute mass, which corresponds to 0.65 ng/mL As in undiluted serum. To our knowledge, the ETA-LEAFS procedure is currently the only one capable of directly measuring As in diluted serum at these levels.

  4. The role of the uncertainty of measurement of serum creatinine concentrations in the diagnosis of acute kidney injury.

    Science.gov (United States)

    Kin Tekce, Buket; Tekce, Hikmet; Aktas, Gulali; Uyeturk, Ugur

    2016-01-01

    Uncertainty of measurement is the numeric expression of the errors associated with all measurements taken in clinical laboratories. Serum creatinine concentration is the most common diagnostic marker for acute kidney injury. The goal of this study was to determine the effect of the uncertainty of measurement of serum creatinine concentrations on the diagnosis of acute kidney injury. We calculated the uncertainty of measurement of serum creatinine according to the Nordtest Guide. Retrospectively, we identified 289 patients who were evaluated for acute kidney injury. Of the total patient pool, 233 were diagnosed with acute kidney injury using the AKIN classification scheme and then were compared using statistical analysis. We determined nine probabilities of the uncertainty of measurement of serum creatinine concentrations. There was a statistically significant difference in the number of patients diagnosed with acute kidney injury when uncertainty of measurement was taken into consideration (first probability compared to the fifth p = 0.023 and first probability compared to the ninth p = 0.012). We found that the uncertainty of measurement for serum creatinine concentrations was an important factor for correctly diagnosing acute kidney injury. In addition, based on the AKIN classification scheme, minimizing the total allowable error levels for serum creatinine concentrations is necessary for the accurate diagnosis of acute kidney injury by clinicians.

  5. Bivariate analysis of basal serum anti-Müllerian hormone measurements and human blastocyst development after IVF

    Directory of Open Access Journals (Sweden)

    Sills E Scott

    2011-12-01

    Full Text Available Abstract Background To report on relationships among baseline serum anti-Müllerian hormone (AMH measurements, blastocyst development and other selected embryology parameters observed in non-donor oocyte IVF cycles. Methods Pre-treatment AMH was measured in patients undergoing IVF (n = 79 and retrospectively correlated to in vitro embryo development noted during culture. Results Mean (+/- SD age for study patients in this study group was 36.3 ± 4.0 (range = 28-45 yrs, and mean (+/- SD terminal serum estradiol during IVF was 5929 +/- 4056 pmol/l. A moderate positive correlation (0.49; 95% CI 0.31 to 0.65 was noted between basal serum AMH and number of MII oocytes retrieved. Similarly, a moderate positive correlation (0.44 was observed between serum AMH and number of early cleavage-stage embryos (95% CI 0.24 to 0.61, suggesting a relationship between serum AMH and embryo development in IVF. Of note, serum AMH levels at baseline were significantly different for patients who did and did not undergo blastocyst transfer (15.6 vs. 10.9 pmol/l; p = 0.029. Conclusions While serum AMH has found increasing application as a predictor of ovarian reserve for patients prior to IVF, its roles to estimate in vitro embryo morphology and potential to advance to blastocyst stage have not been extensively investigated. These data suggest that baseline serum AMH determinations can help forecast blastocyst developmental during IVF. Serum AMH measured before treatment may assist patients, clinicians and embryologists as scheduling of embryo transfer is outlined. Additional studies are needed to confirm these correlations and to better define the role of baseline serum AMH level in the prediction of blastocyst formation.

  6. A rigorous assessment of tree height measurements obtained using airborne LIDAR and conventional field methods.

    Science.gov (United States)

    Hans-Erik Andersen; Stephen E. Reutebuch; Robert J. McGaughey

    2006-01-01

    Tree height is an important variable in forest inventory programs but is typically time-consuming and costly to measure in the field using conventional techniques. Airborne light detection and ranging (LIDAR) provides individual tree height measurements that are highly correlated with field-derived measurements, but the imprecision of conventional field techniques does...

  7. Savinase action on bovine serum albumin (BSA) monolayers demonstrated with measurements at the air-water interface and liquid Atomic Force Microscopy (AFM) imaging

    DEFF Research Database (Denmark)

    Balashev, Konstantin; Callisen, Thomas H; Svendsen, Allan

    2011-01-01

    We studied the enzymatic action of Savinase on bovine serum albumin (BSA) organized in a monolayer spread at the air/water interface or adsorbed at the mica surface. We carried out two types of experiments. In the first one we followed the degradation of the protein monolayer by measuring....... In both cases we obtained an estimate for the turnover number (TON) of the enzyme reaction....

  8. Serum protein capillary electrophoresis and measurement of acute phase proteins in a captive cheetah (Acinonyx jubatus) population

    DEFF Research Database (Denmark)

    Depauw, Sarah; Delanghe, Joris; Whitehouse-Tedd, Katherine

    2014-01-01

    Renal and gastrointestinal pathologies are widespread in the captive cheetah (Acinonyx jubatus) population but are often diagnosed at a late stage, because diagnostic tools are limited to the evaluation of clinical signs or general blood examination. Presently, no data are available on serum...... proteins and acute-phase proteins in cheetahs during health or disease, although they might be important to improve health monitoring. This study aimed to quantify serum proteins by capillary electrophoresis in 80 serum samples from captive cheetahs, categorized according to health status and disease type....... Moreover, serum amyloid A concentrations were measured via a turbidimetric immunoassay validated in domestic cats, whereas haptoglobin and C-reactive protein were determined by non-species-specific functional tests. Cheetahs classified as healthy had serum protein and acute phase protein concentrations...

  9. A constant albumin factor for the calculation of the percentage composition of the serum-protein fraction obtained by elution of paper electrophoresis strips : the azocarmine staining of strips

    NARCIS (Netherlands)

    Meulemans, O.

    A new method of calculating the percentages of serum protein is discussed. This method has a smaller distribution curve than the factor that is generally used for the correction of the extinction of the albumin fraction obtained with the elution method. The magnitude of the new factor is 1.22 ±

  10. Clinical significance of measurement of serum insulin-like growth factor II and adrenomedulion levels in patients with essential hypertension

    International Nuclear Information System (INIS)

    Fan Bifu; Ji Naijun; Mei Yibin; Wang Chengyao; Chen Donghai; Li Fuyuan; Guan Lihua; Gao Meiying

    2003-01-01

    Objective: To investigate the changes of serum levels of insulin-like growth factor II (IGF II) and adrenomedullin (ADM) in patients with essential hypertension. Methods: Serum IGF II and ADM levels were measured in 62 cases of hypertension and 40 controls with RIA. Results: Serum IGF II and ADM levels were significantly bigger in hypertensive patients than those in the controls (t = 4.454, p < 0.01; t = 3.992, p < 0.01). The serum IGF II level was significantly positively correlated to the serum ADM levels (r = 0.379, p < 0.05) and both were significantly positively correlated to the mean arterial pressure (r = 0.346, r = 0.353, p < 0.05) but not with BMI. Serum ADM levels increased gradually as the disease progressed from stage I to stage III (p < 0.05) with levels in stage III markedly higher than those in stage I (p < 0.01). In EH patients with heart and/or brain and/or renal complications the serum ADM levels were significantly higher than those in EH patients without complications (t = 2.050, p < 0.05). Such differences did not exist in the case of IGF II. Conclusion: Serum IGF II and ADM levels were increased markedly in hypertensive patients. These two factors were mutually positively correlated and both were positively correlated to mean arterial pressure. ADM levels increased gradually as the disease progressing but IGF II levels remained stable

  11. Comparison of Lasserre's Measure-based Bounds for Polynomial Optimization to Bounds Obtained by Simulated Annealing

    NARCIS (Netherlands)

    de Klerk, Etienne; Laurent, Monique

    We consider the problem of minimizing a continuous function f over a compact set K. We compare the hierarchy of upper bounds proposed by Lasserre in [SIAM J. Optim. 21(3) (2011), pp. 864-885] to bounds that may be obtained from simulated annealing. We show that, when f is a polynomial and K a convex

  12. Seasonal Changes in Serum Thyrotropin Concentrations Observed from Big Data Obtained During Six Consecutive Years from 2010 to 2015 at a Single Hospital in Japan.

    Science.gov (United States)

    Yoshihara, Ai; Noh, Jaeduk Yoshimura; Watanabe, Natsuko; Iwaku, Kenji; Kunii, Yo; Ohye, Hidemi; Suzuki, Miho; Matsumoto, Masako; Suzuki, Nami; Sugino, Kiminori; Thienpont, Linda M; Hishinuma, Akira; Ito, Koichi

    2018-04-01

    This study analyzed big data for serum thyrotropin (TSH), free triiodothyronine (fT3), and free thyroxine (fT4) concentrations in patients who had attended the outpatient clinic of Ito Hospital (Tokyo, Japan) during a recent six-year period (between January 1, 2010, and December 31, 2015) in order to investigate for seasonal changes. The serum TSH concentrations were reviewed for all 135,417 patients aged >20 years. Patients with any thyroid diseases were included, irrespective of whether they were receiving drug therapy. In total 1,637,721 serum samples were analyzed for TSH, 1,626,269 for fT3, and 1,669,381 for fT4. It was observed that the TSH concentrations showed annual changes during the six-year period. They decreased during the summer, while they increased during the winter. The TSH concentrations were negatively correlated with the daily temperatures (Spearman rank correlation coefficient -0.4486; p < 0.0001). The same applied for the correlation between fT3 concentrations and daily temperatures. The fact that the TSH concentrations show annual changes in areas where the temperature ranges during the year are rather wide should be borne in mind for interpretation of results.

  13. Study of Bovine Serum Albumin Solubility in Aqueous Solutions by Intrinsic Viscosity Measurements

    Directory of Open Access Journals (Sweden)

    Martin Alberto Masuelli

    2013-01-01

    Full Text Available The behavior of bovine serum albumin (BSA in water is scarcely studied, and the thermodynamic properties arising from the experimental measurements have not been reported. Intrinsic viscosity measurements are very useful in assessing the interaction between the solute and solvent. This work discussed in a simple determination of the enthalpy of BSA in aqueous solution when the concentration ranges from 0.2 to 36.71% wt. and the temperature from 35 to 40°C. The relationship between the concentration and intrinsic viscosity is determined according to the method of Huggins. The temperature increase reduces the ratio between inherent viscosity and concentration (ηi/c. This is reflected in the Van't Hoff curve. Furthermore, this work proposes hydrodynamic cohesion value as an indicator of the degree of affinity of protein with water and thermodynamic implications in conformational changes.

  14. A Compendium of Resistance, Sinkage and Trim, and Longitudinal Wave Cut Measurements Obtained on Model 5365

    National Research Council Canada - National Science Library

    Ratchliffe, Toby; Fullerton, Anne; Rice, James; Walker, Don; Russell, Lauren; Fu, Thomas

    2007-01-01

    .... In these experiments drag force was measured using both 6-component Kistler gages and a "traditional" block gage at the tow post location, as well as a Kistler gage located at the grasshopper bracket...

  15. Serum protein capillary electrophoresis and measurement of acute phase proteins in a captive cheetah (Acinonyx jubatus) population.

    Science.gov (United States)

    Depauw, Sarah; Delanghe, Joris; Whitehouse-Tedd, Katherine; Kjelgaard-Hansen, Mads; Christensen, Michelle; Hesta, Myriam; Tugirimana, Pierrot; Budd, Jane; Dermauw, Veronique; Janssens, Geert P J

    2014-09-01

    Renal and gastrointestinal pathologies are widespread in the captive cheetah (Acinonyx jubatus) population but are often diagnosed at a late stage, because diagnostic tools are limited to the evaluation of clinical signs or general blood examination. Presently, no data are available on serum proteins and acute-phase proteins in cheetahs during health or disease, although they might be important to improve health monitoring. This study aimed to quantify serum proteins by capillary electrophoresis in 80 serum samples from captive cheetahs, categorized according to health status and disease type. Moreover, serum amyloid A concentrations were measured via a turbidimetric immunoassay validated in domestic cats, whereas haptoglobin and C-reactive protein were determined by non-species-specific functional tests. Cheetahs classified as healthy had serum protein and acute phase protein concentrations within reference ranges for healthy domestic cats. In contrast, unhealthy cheetahs had higher (P cheetahs suffering from chronic kidney disease were significantly greater compared to the reportedly healthy cheetahs. Our study indicates that serum proteins in the cheetah can be analyzed by routine capillary electrophoresis, whereas acute-phase proteins can be measured using available immunoassays or non-species-specific techniques, which are also likely to be applicable in other exotic felids. Moreover, results suggest that serum amyloid A and haptoglobin are important acute-phase proteins in the diseased cheetah and highlight the need to evaluate their role as early-onset markers for disease.

  16. Use of aluminum nitride to obtain temperature measurements in a high temperature and high radiation environment

    Science.gov (United States)

    Wernsman, Bernard R.; Blasi, Raymond J.; Tittman, Bernhard R.; Parks, David A.

    2016-04-26

    An aluminum nitride piezoelectric ultrasonic transducer successfully operates at temperatures of up to 1000.degree. C. and fast (>1 MeV) neutron fluencies of more than 10.sup.18 n/cm.sup.2. The transducer comprises a transparent, nitrogen rich aluminum nitride (AlN) crystal wafer that is coupled to an aluminum cylinder for pulse-echo measurements. The transducer has the capability to measure in situ gamma heating within the core of a nuclear reactor.

  17. A comparison of oxygen saturation measurements obtained from a 'blue sensor' with a standard sensor.

    Science.gov (United States)

    Mawson, Isabel E; Dawson, Jennifer A; Donath, Susan M; Davis, Peter G

    2011-10-01

    The study aims to investigate pulse oximetry measurements from a 'blue' pulse oximeter sensor against measurements from a 'standard' pulse oximeter sensor in newly born infants. Immediately after birth, both sensors were attached to the infant, one to each foot. SpO₂ measurements were recorded simultaneously from each sensor for 10 min. Agreement between pairs of SpO₂ measurements were calculated using Bland-Altman analysis. Thirty-one infants were studied. There was good correlation between simultaneous SpO₂ measurements from both sensors (r² = 0.75). However, the mean difference between 'blue' and 'standard' sensors was -1.6%, with wide 95% limits of agreement +18.4 to -21.6%. The range of mean difference between sensors from each infant ranged from -20 to +20. The mean difference between the blue and standard sensor SpO₂ measurements is not clinically important. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  18. Electron beam water calorimetry measurements to obtain beam quality conversion factors.

    Science.gov (United States)

    Muir, Bryan R; Cojocaru, Claudiu D; McEwen, Malcolm R; Ross, Carl K

    2017-10-01

    To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, k Q , for several ion chamber types. Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator. Ion chamber measurements are made as a function of depth for cylindrical and plane-parallel ion chambers over a period of five years to investigate the stability of ion chamber response and for indirect calibration. Water calorimetry measurements are made in 18 MeV and 22 MeV beams. An insulated enclosure with fine temperature control is used to maintain a constant temperature (drifts less than 0.1 mK/min) of the calorimeter phantom at 4°C to minimize effects from convection. Two vessels of different designs are used with calibrated thermistor probes to measure radiation induced temperature rise. The vessels are filled with high-purity water and saturated with H 2 or N 2 gas to minimize the effect of radiochemical reactions on the measured temperature rise. A set of secondary standard ion chambers are calibrated directly against the calorimeter. Finally, several other ion chambers are calibrated in the NRC 60 Co reference field and then cross-calibrated against the secondary standard chambers in electron beams to realize k Q factors. The long-term stability of the cylindrical ion chambers in electron beams is better (always <0.15%) than plane-parallel chambers (0.2% to 0.4%). Calorimetry measurements

  19. Modifiable risk factors promoting neurodegeneration is associated with two novel brain degradation markers measured in serum

    DEFF Research Database (Denmark)

    Neergaard, Jesper; Møller, Katrine Dragsbæk; Christiansen, Claus

    2017-01-01

    truncated tau fragments (Tau-A and Tau-C) in serum. Platelets, albumin and several modifiable risk factors, including Body Mass Index, high density lipoprotein and White Blood Cell count were associated with the serum level of tau fragments. The factors associated with tau in serum may promote...

  20. Obtaining sub-daily new snow density from automated measurements in high mountain regions

    Science.gov (United States)

    Helfricht, Kay; Hartl, Lea; Koch, Roland; Marty, Christoph; Olefs, Marc

    2018-05-01

    The density of new snow is operationally monitored by meteorological or hydrological services at daily time intervals, or occasionally measured in local field studies. However, meteorological conditions and thus settling of the freshly deposited snow rapidly alter the new snow density until measurement. Physically based snow models and nowcasting applications make use of hourly weather data to determine the water equivalent of the snowfall and snow depth. In previous studies, a number of empirical parameterizations were developed to approximate the new snow density by meteorological parameters. These parameterizations are largely based on new snow measurements derived from local in situ measurements. In this study a data set of automated snow measurements at four stations located in the European Alps is analysed for several winter seasons. Hourly new snow densities are calculated from the height of new snow and the water equivalent of snowfall. Considering the settling of the new snow and the old snowpack, the average hourly new snow density is 68 kg m-3, with a standard deviation of 9 kg m-3. Seven existing parameterizations for estimating new snow densities were tested against these data, and most calculations overestimate the hourly automated measurements. Two of the tested parameterizations were capable of simulating low new snow densities observed at sheltered inner-alpine stations. The observed variability in new snow density from the automated measurements could not be described with satisfactory statistical significance by any of the investigated parameterizations. Applying simple linear regressions between new snow density and wet bulb temperature based on the measurements' data resulted in significant relationships (r2 > 0.5 and p ≤ 0.05) for single periods at individual stations only. Higher new snow density was calculated for the highest elevated and most wind-exposed station location. Whereas snow measurements using ultrasonic devices and snow

  1. Measurement of FA and VitB12 in serum by TRFIA and its clinical application

    International Nuclear Information System (INIS)

    Zhou Jinhong; Wang Huimin

    2006-01-01

    To investigate the correlation between diseases and the quantity of folic acid(FA) and vitamine B 12 (VitB 12 ) in serum, the quantity of FA and VitB 12 in serum was measured by TR- FIA. The results showed that the levels of FA and VitB 12 in 68 controlled subjects were 20.13±5.72 nmol/L and 240.45±58.23 pmol/L respectively. The levels of FA and VitB 12 in 6 patients with megaloblastic anemia, 26 with medium-terminal gestation femineity, 7 with liver cirrhosis, 10 with gastric ulcerand 31 with cerebral infarction were significant lower than those in the control group. The level of FA in 24 with malignant hematopathy and 57 with malignant tumor was significantly lower but VitB 12 between the 31 patients with iron deficiency anemia and 12 with CAA and the control group. The amount of the FA in 9 patients with chronic atrophic gastritis and 42 blood donors were lower than that in the control. The determination of FA and VitB 12 levels may be quite significant in the diagnosis, therapy and prognosis of diseases. Laboratories should establish the reference values which fit the locals specifically. (authors)

  2. Measurement of serum TGA, TPOAb levels with ECLEIA in patients with Hashimoto thyroiditis

    International Nuclear Information System (INIS)

    Yu Yuanjun; Chen Qiao; Quan Cheng; Tang Jinxian

    2007-01-01

    Objective: To determine the serum autoantibodies contents during different clinical stages in patients with Hashimoto thyroiditis. Methods: Serum TGA and TPOAb were detected with chemiluminescence enzyme immunoassay (ECLEIA) and RIA simultaneously in 125 patients with Hashimoto thyroiditis. Results: HT with hyperthyroidism (12 cases) TGA: ECLEIA, (621 + 245 ) IU/ml, positive rate: 83.3%, RIA:66.7%, TPOAb: ECLEIA (452 ± 203) IU/ml, positive rates: 100%, RIA:75.0%, HT with hypothyroidism (50 cases): TGA: ECLEIA ( 1152 + 420) IU/ml. Positive Rates: 94.0%, RIA: 88.0%, TPOAb: (482 + 302) IU/ml. Positive Rates: 96.0%, RIA:90.9%; HT with normal thyroid function (63 cases): TGA: ECLEIA (230 ± 186) IU/ml. Positive Rates: 58.7%, RIA:38.1%, TPOAb:(302 ± 201)IU/ml. Positive Rates: 92.1%, RIA: 63.5%. Conclusion: Measurement of TGA and TPOAb with ECLEIA is much more sensitive than that with the conventional RIA. (authors)

  3. Radon in Estonian buildings. Establishment of a measurement system and obtained results

    International Nuclear Information System (INIS)

    Pahapill, L.; Rulkov, A.; Swedjemark, G.A.

    1996-12-01

    One purpose of this project was the establishment of a radon monitoring programme inside the state environmental monitoring programme. Another purpose was to investigate regions, expected to have high radon levels indoors. A new method for the long-term measurement of indoor radon was established and the staff for these measurements was trained. The results of the measurement can be used by Estonian decision-makers to work out rules and standards. There is no legislative act in the field of radiation in Estonian at this time. To summarize the results of the measurements we can say that indoor radon concentrations vary by region. The radon investigations must be continued to identify the risk areas and types of housing construction. The results of the state radon monitoring are provided to the municipalities, who advice the owners of planned new houses to select the right construction for the house. A new project will follow with an investigation of radon in randomly selected dwellings, training and equipment for radon measurement in soil, and general advice with regard to radon, as well as assistance in preparing information about radon. 7 refs, 5 figs

  4. Crystal fields of dilute Tb, Dy, Ho, or Er in Lu obtained by magnetization measurements

    International Nuclear Information System (INIS)

    Touborg, P.; Hog, J.

    1975-01-01

    Magnetization measurements are reported on single crystals of dilute Tb, Dy, Ho, or Er in Lu. These measurements were performed in the temperature range 1.5--100 K and field range 0--6 T and include measurements of initial susceptibility, isothermal and isofield magnetization, and basal-plane anisotropy. The results show features similar to the corresponding Y-R alloys, where R is a rare earth. Crystal-field and molecular-field parameters could be unabiguously deduced from the experimental data. The effects of crystal-field level broadening were investigated and demonstrated for Ho. Comparison of the Y-R and Lu-R results makes possible an estimate of the crystal-field parameters in the pure-rare-earth metals

  5. The Effects of Survey Timing on Student Evaluation of Teaching Measures Obtained Using Online Surveys

    Science.gov (United States)

    Estelami, Hooman

    2015-01-01

    Teaching evaluations are an important measurement tool used by business schools in gauging the level of student satisfaction with the educational services delivered by faculty. The growing use of online teaching evaluations has enabled educational administrators to expand the time period during which student evaluation of teaching (SET) surveys…

  6. Measurements of cardiac output obtained with transesophageal echocardiography and pulmonary artery thermodilution are not interchangeable

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Graeser, K; Hansen, K L

    2014-01-01

    was placed in the following successive positions: supine, head-down tilt, head-up tilt, supine, supine with phenylephrine administration, pace heart rate 80 beats per minute (bpm), pace heart rate 110 bpm. TEE CO and PAC CO were measured simultaneously. The agreement was analysed by Bland-Altman plots...

  7. Ensuring validity of radiometric temperature measurements obtained in the field using infrared imagers

    CSIR Research Space (South Africa)

    Mudau, AE

    2010-11-01

    Full Text Available When a military aircraft becomes the target of an approaching infrared seeker missile, it relies on infrared counter-measures to serve as decoys and to confuse the missile. The Optronic Sensor Systems (OSS) group at CSIR-DPSS is involved in computer...

  8. Methods for obtaining true particle size distributions from cross section measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lord, Kristina Alyse [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    Sectioning methods are frequently used to measure grain sizes in materials. These methods do not provide accurate grain sizes for two reasons. First, the sizes of features observed on random sections are always smaller than the true sizes of solid spherical shaped objects, as noted by Wicksell [1]. This is the case because the section very rarely passes through the center of solid spherical shaped objects randomly dispersed throughout a material. The sizes of features observed on random sections are inversely related to the distance of the center of the solid object from the section [1]. Second, on a plane section through the solid material, larger sized features are more frequently observed than smaller ones due to the larger probability for a section to come into contact with the larger sized portion of the spheres than the smaller sized portion. As a result, it is necessary to find a method that takes into account these reasons for inaccurate particle size measurements, while providing a correction factor for accurately determining true particle size measurements. I present a method for deducing true grain size distributions from those determined from specimen cross sections, either by measurement of equivalent grain diameters or linear intercepts.

  9. An analysis of boundary-effects in obtaining the frequency dependent specific heat by effusivity measurements

    DEFF Research Database (Denmark)

    Christensen, Tage Emil; Behrens, Claus

    The frequency dependent specific heat is a significant response function characterizing the glass transition. Contrary to the dielectric response it is not easily measured over many decades. The introduction of the 3-omega method, where the temperature oscillations at a planar oscillatoric heat g...

  10. Impedance measurements on oxide films on aluminium obtained by pulsed tensions

    Energy Technology Data Exchange (ETDEWEB)

    Belmokre, K. [Lab. of Applied Chemical, Dept. of Chemie, Skikda University, BP 26 - 21000 Skikda (Algeria); Azzouz, N. [Dept. of Industrial Chemie, Jijel University Center, 18000 Jijel (Algeria); Hannani, A. [Lab. Electrochem. Corros. Institute of Chemical USTHB Alger (Algeria); Pagetti, J. [Lab. LCMI, Franche-Comte - University UFR Sciences and Technical 16, Gray street - 25030 Besancon Cedex (France)

    2003-01-01

    We have performed this study on oxide films sealed or not in boiling water. The films are first obtained on type 1050 A aluminium substrate by pulsed tensions anodizing technique, in a sulfuric acid solution. Afterwards the, Electrochemical Impedance Spectroscopy (EIS) is employed to appreciate the films behaviour in a neutral solution of 3.5% K{sub 2}SO{sub 4}, in which the interface processes interest only the ageing phenomenon of the oxide films and not their corrosion. We have also attempted a correlation between pulse parameters of anodization and the electrical parameters characterizing these films. The sealing influence on ageing has been studied as well. For all films, ageing is appreciated using impedance diagrams evolution versus time. The results show: - the existence of two capacitive loops confirming the presence of two oxide layers characteristic of oxide films obtained in a sulfuric acid medium. The first loop, at high frequencies, is related to the external porous layer and the second one, at lower frequencies, is related to the internal barrier layer. - the thickness of the barrier layer varies between 25 and 40 nm in relation with the electrical pulse parameters. - the sealing acts favorably against anodic oxide films ageing. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  11. Interpretation of acoustic parameters obtained by EMAR measurement for non-destructive hydrogen concentration measurement in Zr alloy

    International Nuclear Information System (INIS)

    Nakatsuka, Masafumi; Uchida, Katsuya; Miyazaki, Akihiro; Ishii, Yoshiaki

    2007-01-01

    An obvious quantitative relation between hydrogen concentrations in zirconium alloy and acoustic anisotropy parameters obtained by the electromagnetic acoustic resonance (EMAR) method was reported. To elucidate the mechanism, the acoustic parameters were calculated based on the elastic theory and the equation of motion. The acoustic parameters of obtained by the EMAR method were interpreted quantitatively using the anisotropic elastic constants of the specimen, and value calculated from texture data for non-hydrogen charged specimens showed good agreement with those obtained by the EMAR method. Calculated temperature dependence of the acoustic anisotropy for the non-hydrogen charged specimen also agreed well with that by the EMAR method. The consistencies demonstrated that the absolute values of the acoustic parameters for non-hydrogen charged specimen can be calculated from both the texture data of (0002) pole figure and the elastic constants of the specimen. Hydrogen addition up to approximately 650ppm was found not to change the original (0002) pole figure and, correspondingly, no hydrogen concentration dependence of the acoustic parameters was obtained from the calculation. These results implied that the zirconium hydride itself played an important role for the change in the acoustic parameters of the hydrogen charged specimens, and the importance of obtaining the information on the elastic constants of the zirconium hydride was pointed out. (author)

  12. Diagnostic relevance of radioiron-absorption-measurements and immunoradiometric serum-ferritin-assay in the evaluation of iron stores

    International Nuclear Information System (INIS)

    Heinrich, H.C.

    1978-01-01

    Negative iron balance and enhanced iron demand respectively causes deficient iron stores (prelatent iron deficiency) with increased iron absorption, later on decrease of serum iron and increase of transferrin (latent Fe deficiency) and at least iron deficient anemia (manifest iron deficiency). In prelatend iron deficiency diagnostic 59 Fe 2+ absorption is increased and the RES cells do not show storage iron cytochemically. In latent iron deficiency in addition serum iron, transferrin iron saturation and serum ferritin is decreased and hypochromic mikrocytic anemia completes the signs of manifest iron deficiency. Besides rare cases of primary hemochromatosis and marked hyperdasia of ineffective erythropoiesis in homocygotic beta-thalassemia, hereditary non-spherocytic hemolytic anemia caused by pyruvate kinase deficiency and some sideroblastic anemias increased 59 Fe 2+ absorption is a reliable measure of exhausted iron stores. In these exceptional cases differential diagnosis between sideroachrestic and siderosensitive iron deficiency anemia can be made by measurement of serum iron and serum ferritin respectively. The etiology of iron deficiency is to be cleared by measurement of 59 Fe absorption from 59 Fe 2+ and 59 Fe-marked meat with consecutive estimation of whole body 59 Fe elimination. Shortly after completion or during oral iron therapy serum ferritin concentration is not suitable to evaluate the content of iron stores. (orig.) [de

  13. Clinical value of the joint measurement of serum concentrations of type IV collagen and laminin in patients with diabetic nephropathy

    International Nuclear Information System (INIS)

    Wang Lu; Wang Ping; Li Yongpei

    2004-01-01

    Objective: To study clinical value of the joint measurement of serum concentrations of type IV collagen (IV C) and laminin (LN) in patients with diabetic nephropathy (DN) by radioimmunoassay (RIA). Methods: Serum concentrations of IV C, LN were measured by RIA in 35 diabetic patients with normalbuminuria (group A), 28 cases of microalbuminuria (group B), 15 cases of macroalbuminuria (group C) and 30 normal subjects as control . Results: The serum concentrations of IV C, LN in total 78 diabetic patients [(97.6 ± 19.2), (132.4 ± 31.5) μg/L] were higher than that of the controls [(77.4 ± 8.2), (101.5 ± 17.6) μg/L, P<0.05], especially in group B and C, it was remarkably higher compared with the controls (P<0.05, P<0.01). There was significant positive correlation of serum IV C, LN to diabetic duration and the levels of blood urea nitrogen (BUN), creatinine (Cr), urinary albumin excretion rate (UAER). Conclusions: The results suggest that the joint measurement of serum levels of IV C, LN and UAER in DN patients might better evaluate the development process of DN, and be of help for early diagnosis and treatment of DN. Serum levels of IV C, LN and UAER in DN patients may become the reliable clinical markers for assessing the severity and predicting the prognosis of DN

  14. A NEW RECIPE FOR OBTAINING CENTRAL VOLUME DENSITIES OF PRESTELLAR CORES FROM SIZE MEASUREMENTS

    International Nuclear Information System (INIS)

    Tassis, Konstantinos; Yorke, Harold W.

    2011-01-01

    We propose a simple analytical method for estimating the central volume density of prestellar molecular cloud cores from their column density profiles. Prestellar cores feature a flat central part of the column density and volume density profiles of the same size indicating the existence of a uniform-density inner region. The size of this region is set by the thermal pressure force which depends only on the central volume density and temperature of the core, and can provide a direct measurement of the central volume density. Thus, a simple length measurement can immediately yield a central density estimate independent of any dynamical model for the core and without the need for fitting. Using the radius at which the column density is 90% of the central value as an estimate of the size of the flat inner part of the column density profile yields an estimate of the central volume density within a factor of two for well-resolved cores.

  15. Reliability of biceps femoris and semitendinosus muscle architecture measurements obtained with ultrasonography

    Directory of Open Access Journals (Sweden)

    Viviane Bastos de Oliveira

    Full Text Available Introduction Currently, little attention is given to the muscle architecture reliability studies of the hamstring using a robust statistical. Our purpose was to determine the reliability of ultrasound measurements of muscle thickness, fascicle length and pennation angle of the biceps femoris and semitendinosus muscles, including heteroskedasticity and internal consistency analyses. Methods Two images of biceps femoris and semitendinosus at 50% of the thigh length were acquired from 21 volunteers, in two visits. The parameters were measured three times in each image, and for each muscle. The reliability was analyzed by the intraclass correlation coefficient (ICC and Cronbach’s alpha (αCronbach. The relative standard error of the measurements (%SEM were calculated and Bland-Altman plots were generated. Results All parameters presented excellent ICC for the three repeated measurements (ICC from 0.93 ‒ 0.99 and moderate to excellent reliability intraday (ICC from 0.70 ‒ 0.95 for both muscles. The present study indicates that ultrasound is a reliable tool to estimate the biceps femoris fascicle length (ICC = 0.97, αCronbach = 0.98, %SEM = 7.86 and semitendinosus (ICC = 0.90, αCronbach = 0.95, %SEM = 7.55, as well as the biceps femoris muscle thickness (ICC = 0.89, αCronbach = 0.94, %SEM = 10.23 and semitendinosus muscle thickness (ICC = 0.87, αCronbach = 0.93, %SEM = 1.35. At last, biceps femoris pennation angle (ICC = 0.93, αCronbach = 0.96 and %SEM = 4.36 and semitendinosus (ICC = 0.96, αCronbach = 0.98 and %SEM = 4.25 also had good repeatability. Conclusion Ultrasonography show good repeatability in estimating of muscle architecture parameters.

  16. Evidence of the extended orientational order in amorphous alloys obtained from magnetic measurements

    International Nuclear Information System (INIS)

    Chudnovsky, E.M.; Tejada, J.

    1993-01-01

    Magnetic measurements of R-Fe-B (R = rare earth) amorphous alloys show that magnetic anisotropy axes are correlated on the scale ∼ 100 A. The X-ray study of these materials does not reveal any positional correlations beyond the 10 A scale. These observations support theoretical suggestions that the orientational order in amorphous systems can be much more extended than the positional order. (orig.)

  17. Development, calibration and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

    International Nuclear Information System (INIS)

    Carcreff, H.; Cloute-Cazalaa, V.; Salmon, L.

    2011-01-01

    Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Div. at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

  18. Development, calibration, and experimental results obtained with an innovative calorimeter (CALMOS) for nuclear heating measurements

    International Nuclear Information System (INIS)

    Carcreff, Hubert; Cloute-Cazalaa, Veronique; Salmon, Laurent

    2012-01-01

    Nuclear heating inside an MTR reactor has to be known in order to be able to control samples temperature during irradiation experiments. An R and D program has been carried out at CEA to design a new type of in-core calorimetric system. This new development, started in 2002, has for main objective to manufacture a calorimeter suitable to monitoring nuclear heating inside the 70 MWth OSIRIS material testing reactor operated by CEA's Nuclear Energy Division at the Saclay research center. An innovative calorimetric probe, associated to a specific handling system, has been designed to provide access to measurements both along the fissile height and on the upper part of the core, where nuclear heating still remains high. Two mock-ups of the probe were manufactured and tested in 2005 and 2009 in ex-core area of OSIRIS reactor for process validation, while a displacement system has been especially studied to move the probe along a given axial measurement range. This paper deals with the development, tests on preliminary mock-ups and the finalization of the probe. Main modeling and experimental results are presented. Moreover, alternative methods to calibration for nuclear heating rate measurements which are now possible with this new calorimeter are presented and discussed. (authors)

  19. Revisitation of FRET methods to measure intraprotein distances in Human Serum Albumin

    Energy Technology Data Exchange (ETDEWEB)

    Santini, S.; Bizzarri, A.R.; Cannistraro, S., E-mail: cannistr@unitus.it

    2016-11-15

    We revisited the FRET methods to measure the intraprotein distance between Trp-214 (used as donor) of Human Serum Albumin and its Cys-34, labelled with 1.5-Iaedans (used as acceptor). Variation of Trp fluorescence emission in terms of both intensity and lifetime, as well the enhancement of the acceptor fluorescence emission upon Trp excitation, have been monitored. A careful statistical analysis of the fluorescence results from ten independently prepared samples, combined with suitable spectral corrections, provided reproducible distances estimations by each one of the three methods. Even if monitoring of the donor lifetime variation in the presence of the acceptor reproduces at the best the crystallographic data, by allowing even sub-nanometre distance variations to be appreciated, we suggest that a comparative analysis of all the three methods, applied with statistical significance, should be preferred to achieve a better reliability of the FRET technique.

  20. Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

    International Nuclear Information System (INIS)

    Mathieu, Kelsey B.; McNitt-Gray, Michael F.; Zhang, Di; Kim, Hyun J.; Cody, Dianna D.

    2010-01-01

    Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI 100,air ); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI w ) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI 100,air values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI 100,air ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI w for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).

  1. Polarization measurement and vertical aperture optimization for obtaining circularly polarized bend-magnet radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kortright, J.B.; Rice, M.; Hussain, Z. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    Growing interest in utilizing circular polarization prompted the design of bend-magnet beamline 9.3.2 at the Advanced Light Source, covering the 30-1500 eV spectral region, to include vertical aperturing capabilities for optimizing the collection of circular polarization above and below the orbit plane. After commissioning and early use of the beamline, a multilayer polarimeter was used to characterize the polarization state of the beam as a function of vertical aperture position. This report partially summarizes the polarimetry measurements and compares results with theoretical calculations intended to simulate experimental conditions.

  2. Electron and phonon properties of 25 A-15 superconductors obtained from heat capacity measurements

    International Nuclear Information System (INIS)

    Junod, A.

    1982-01-01

    We review 25 specific heat measurements performed in Geneva on binary and pseudo-binary A-15 compounds. The rather extended temperature range allows us to make reliable estimates of several moments of the phonon spectrum which are required in the theory of superconductivity. The Tsub(c) expression of Allen and Dynes can then be used consistently to estimate the microscopic parameters lambda, eta, Nsub(bs) (Esub(F)), etc. The broad range of values reviewed permits to establish significant correlations between the parameters in stoichiometric and ordered compounds. (orig.)

  3. Ocean current surface measurement using dynamic elevations obtained by the GEOS-3 radar altimeter

    Science.gov (United States)

    Leitao, C. D.; Huang, N. E.; Parra, C. G.

    1977-01-01

    Remote Sensing of the ocean surface from the GEOS-3 satellite using radar altimeter data has confirmed that the altimeter can detect the dynamic ocean topographic elevations relative to an equipotential surface, thus resulting in a reliable direct measurement of the ocean surface. Maps of the ocean dynamic topography calculated over a one month period and with 20 cm contour interval are prepared for the last half of 1975. The Gulf Stream is observed by the rapid slope change shown by the crowding of contours. Cold eddies associated with the current are seen as roughly circular depressions.

  4. Evaluation of Hydraulic Parameters Obtained by Different Measurement Methods for Heterogeneous Gravel Soil

    Directory of Open Access Journals (Sweden)

    Chen Zeng

    2012-01-01

    Full Text Available Knowledge of soil hydraulic parameters for the van Genuchten function is important to characterize soil water movement for watershed management. Accurate and rapid prediction of soil water flow in heterogeneous gravel soil has become a hot topic in recent years. However, it is difficult to precisely estimate hydraulic parameters in a heterogeneous soil with rock fragments. In this study, the HYDRUS-2D numerical model was used to evaluate hydraulic parameters for heterogeneous gravel soil that was irregularly embedded with rock fragments in a grape production base. The centrifugal method (CM, tensiometer method (TM and inverse solution method (ISM were compared for various parameters in the van Genuchten function. The soil core method (SCM, disc infiltration method (DIM and inverse solution method (ISM were also investigated for measuring saturated hydraulic conductivity. Simulation with the DIM approach revealed a problem of overestimating soil water infiltration whereas simulation with the SCM approach revealed a problem of underestimating water movement as compared to actual field observation. The ISM approach produced the best simulation result even though this approach slightly overestimated soil moisture by ignoring the impact of rock fragments. This study provides useful information on the overall evaluation of soil hydraulic parameters attained with different measurement methods for simulating soil water movement and distribution in heterogeneous gravel soil.

  5. Event generator tunes obtained from underlying event and multiparton scattering measurements

    CERN Document Server

    Khachatryan, Vardan; Tumasyan, Armen; Adam, Wolfgang; Aşılar, Ece; Bergauer, Thomas; Brandstetter, Johannes; Brondolin, Erica; Dragicevic, Marko; Erö, Janos; Flechl, Martin; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hartl, Christian; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Knünz, Valentin; König, Axel; Krammer, Manfred; Krätschmer, Ilse; Liko, Dietrich; Matsushita, Takashi; Mikulec, Ivan; Rabady, Dinyar; Rahbaran, Babak; Rohringer, Herbert; Schieck, Jochen; Schöfbeck, Robert; Strauss, Josef; Treberer-Treberspurg, Wolfgang; Waltenberger, Wolfgang; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Alderweireldt, Sara; Cornelis, Tom; De Wolf, Eddi A; Janssen, Xavier; Knutsson, Albert; Lauwers, Jasper; Luyckx, Sten; Van De Klundert, Merijn; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Van Spilbeeck, Alex; Abu Zeid, Shimaa; Blekman, Freya; D'Hondt, Jorgen; Daci, Nadir; De Bruyn, Isabelle; Deroover, Kevin; Heracleous, Natalie; Keaveney, James; Lowette, Steven; Moreels, Lieselotte; Olbrechts, Annik; Python, Quentin; Strom, Derek; Tavernier, Stefaan; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Van Parijs, Isis; Barria, Patrizia; Brun, Hugues; Caillol, Cécile; Clerbaux, Barbara; De Lentdecker, Gilles; Fasanella, Giuseppe; Favart, Laurent; Grebenyuk, Anastasia; Karapostoli, Georgia; Lenzi, Thomas; Léonard, Alexandre; Maerschalk, Thierry; Marinov, Andrey; Perniè, Luca; Randle-conde, Aidan; Seva, Tomislav; Vander Velde, Catherine; Vanlaer, Pascal; Yonamine, Ryo; Zenoni, Florian; Zhang, Fengwangdong; Beernaert, Kelly; Benucci, Leonardo; Cimmino, Anna; Crucy, Shannon; Dobur, Didar; Fagot, Alexis; Garcia, Guillaume; Gul, Muhammad; Mccartin, Joseph; Ocampo Rios, Alberto Andres; Poyraz, Deniz; Ryckbosch, Dirk; Salva Diblen, Sinem; Sigamani, Michael; Tytgat, Michael; Van Driessche, Ward; Yazgan, Efe; Zaganidis, Nicolas; Basegmez, Suzan; Beluffi, Camille; Bondu, Olivier; Brochet, Sébastien; Bruno, Giacomo; Caudron, Adrien; Ceard, Ludivine; Da Silveira, Gustavo Gil; Delaere, Christophe; Favart, Denis; Forthomme, Laurent; Giammanco, Andrea; Hollar, Jonathan; Jafari, Abideh; Jez, Pavel; Komm, Matthias; Lemaitre, Vincent; Mertens, Alexandre; Musich, Marco; Nuttens, Claude; Perrini, Lucia; Pin, Arnaud; Piotrzkowski, Krzysztof; Popov, Andrey; Quertenmont, Loic; Selvaggi, Michele; Vidal Marono, Miguel; Beliy, Nikita; Hammad, Gregory Habib; Aldá Júnior, Walter Luiz; Alves, Fábio Lúcio; Alves, Gilvan; Brito, Lucas; Correa Martins Junior, Marcos; Hamer, Matthias; Hensel, Carsten; Moraes, Arthur; Pol, Maria Elena; Rebello Teles, Patricia; Belchior Batista Das Chagas, Ewerton; Carvalho, Wagner; Chinellato, Jose; Custódio, Analu; Melo Da Costa, Eliza; De Jesus Damiao, Dilson; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Huertas Guativa, Lina Milena; Malbouisson, Helena; Matos Figueiredo, Diego; Mora Herrera, Clemencia; Mundim, Luiz; Nogima, Helio; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Sznajder, Andre; Tonelli Manganote, Edmilson José; Vilela Pereira, Antonio; Ahuja, Sudha; Bernardes, Cesar Augusto; De Souza Santos, Angelo; Dogra, Sunil; Tomei, Thiago; De Moraes Gregores, Eduardo; Mercadante, Pedro G; Moon, Chang-Seong; Novaes, Sergio F; Padula, Sandra; Romero Abad, David; Ruiz Vargas, José Cupertino; Aleksandrov, Aleksandar; Hadjiiska, Roumyana; Iaydjiev, Plamen; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Vutova, Mariana; Dimitrov, Anton; Glushkov, Ivan; Litov, Leander; Pavlov, Borislav; Petkov, Peicho; Ahmad, Muhammad; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Chen, Mingshui; Cheng, Tongguang; Du, Ran; Jiang, Chun-Hua; Plestina, Roko; Romeo, Francesco; Shaheen, Sarmad Masood; Spiezia, Aniello; Tao, Junquan; Wang, Chunjie; Wang, Zheng; Zhang, Huaqiao; Asawatangtrakuldee, Chayanit; Ban, Yong; Li, Qiang; Liu, Shuai; Mao, Yajun; Qian, Si-Jin; Wang, Dayong; Xu, Zijun; Avila, Carlos; Cabrera, Andrés; Chaparro Sierra, Luisa Fernanda; Florez, Carlos; Gomez, Juan Pablo; Gomez Moreno, Bernardo; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Puljak, Ivica; Ribeiro Cipriano, Pedro M; Antunovic, Zeljko; Kovac, Marko; Brigljevic, Vuko; Kadija, Kreso; Luetic, Jelena; Micanovic, Sasa; Sudic, Lucija; Attikis, Alexandros; Mavromanolakis, Georgios; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Rykaczewski, Hans; Bodlak, Martin; Finger, Miroslav; Finger Jr, Michael; Abdelalim, Ahmed Ali; Awad, Adel; Mahrous, Ayman; Mohammed, Yasser; Radi, Amr; Calpas, Betty; Kadastik, Mario; Murumaa, Marion; Raidal, Martti; Tiko, Andres; Veelken, Christian; Eerola, Paula; Pekkanen, Juska; Voutilainen, Mikko; Härkönen, Jaakko; Karimäki, Veikko; Kinnunen, Ritva; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Peltola, Timo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Wendland, Lauri; Talvitie, Joonas; Tuuva, Tuure; Besancon, Marc; Couderc, Fabrice; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Favaro, Carlotta; Ferri, Federico; Ganjour, Serguei; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Machet, Martina; Malcles, Julie; Rander, John; Rosowsky, André; Titov, Maksym; Zghiche, Amina; Antropov, Iurii; Baffioni, Stephanie; Beaudette, Florian; Busson, Philippe; Cadamuro, Luca; Chapon, Emilien; Charlot, Claude; Dahms, Torsten; Davignon, Olivier; Filipovic, Nicolas; Granier de Cassagnac, Raphael; Jo, Mihee; Lisniak, Stanislav; Mastrolorenzo, Luca; Miné, Philippe; Naranjo, Ivo Nicolas; Nguyen, Matthew; Ochando, Christophe; Ortona, Giacomo; Paganini, Pascal; Pigard, Philipp; Regnard, Simon; Salerno, Roberto; Sauvan, Jean-Baptiste; Sirois, Yves; Strebler, Thomas; Yilmaz, Yetkin; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Aubin, Alexandre; Bloch, Daniel; Brom, Jean-Marie; Buttignol, Michael; Chabert, Eric Christian; Chanon, Nicolas; Collard, Caroline; Conte, Eric; Coubez, Xavier; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Goetzmann, Christophe; Le Bihan, Anne-Catherine; Merlin, Jeremie Alexandre; Skovpen, Kirill; Van Hove, Pierre; Gadrat, Sébastien; Beauceron, Stephanie; Bernet, Colin; Boudoul, Gaelle; Bouvier, Elvire; Carrillo Montoya, Camilo Andres; Chierici, Roberto; Contardo, Didier; Courbon, Benoit; Depasse, Pierre; El Mamouni, Houmani; Fan, Jiawei; Fay, Jean; Gascon, Susan; Gouzevitch, Maxime; Ille, Bernard; Lagarde, Francois; Laktineh, Imad Baptiste; Lethuillier, Morgan; Mirabito, Laurent; Pequegnot, Anne-Laure; Perries, Stephane; Ruiz Alvarez, José David; Sabes, David; Sgandurra, Louis; Sordini, Viola; Vander Donckt, Muriel; Verdier, Patrice; Viret, Sébastien; Toriashvili, Tengizi; Lomidze, David; Autermann, Christian; Beranek, Sarah; Edelhoff, Matthias; Feld, Lutz; Heister, Arno; Kiesel, Maximilian Knut; Klein, Katja; Lipinski, Martin; Ostapchuk, Andrey; Preuten, Marius; Raupach, Frank; Schael, Stefan; Schulte, Jan-Frederik; Verlage, Tobias; Weber, Hendrik; Wittmer, Bruno; Zhukov, Valery; Ata, Metin; Brodski, Michael; Dietz-Laursonn, Erik; Duchardt, Deborah; Endres, Matthias; Erdmann, Martin; Erdweg, Sören; Esch, Thomas; Fischer, Robert; Güth, Andreas; Hebbeker, Thomas; Heidemann, Carsten; Hoepfner, Kerstin; Knutzen, Simon; Kreuzer, Peter; Merschmeyer, Markus; Meyer, Arnd; Millet, Philipp; Olschewski, Mark; Padeken, Klaas; Papacz, Paul; Pook, Tobias; Radziej, Markus; Reithler, Hans; Rieger, Marcel; Scheuch, Florian; Sonnenschein, Lars; Teyssier, Daniel; Thüer, Sebastian; Cherepanov, Vladimir; Erdogan, Yusuf; Flügge, Günter; Geenen, Heiko; Geisler, Matthias; Hoehle, Felix; Kargoll, Bastian; Kress, Thomas; Kuessel, Yvonne; Künsken, Andreas; Lingemann, Joschka; Nehrkorn, Alexander; Nowack, Andreas; Nugent, Ian Michael; Pistone, Claudia; Pooth, Oliver; Stahl, Achim; Aldaya Martin, Maria; Asin, Ivan; Bartosik, Nazar; Behnke, Olaf; Behrens, Ulf; Bell, Alan James; Borras, Kerstin; Burgmeier, Armin; Campbell, Alan; Choudhury, Somnath; Costanza, Francesco; Diez Pardos, Carmen; Dolinska, Ganna; Dooling, Samantha; Dorland, Tyler; Eckerlin, Guenter; Eckstein, Doris; Eichhorn, Thomas; Flucke, Gero; Gallo, Elisabetta; Garay Garcia, Jasone; Geiser, Achim; Gizhko, Andrii; Gunnellini, Paolo; Hauk, Johannes; Hempel, Maria; Jung, Hannes; Kalogeropoulos, Alexis; Karacheban, Olena; Kasemann, Matthias; Katsas, Panagiotis; Kieseler, Jan; Kleinwort, Claus; Korol, Ievgen; Lange, Wolfgang; Leonard, Jessica; Lipka, Katerina; Lobanov, Artur; Lohmann, Wolfgang; Mankel, Rainer; Marfin, Ihar; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mittag, Gregor; Mnich, Joachim; Mussgiller, Andreas; Naumann-Emme, Sebastian; Nayak, Aruna; Ntomari, Eleni; Perrey, Hanno; Pitzl, Daniel; Placakyte, Ringaile; Raspereza, Alexei; Roland, Benoit; Sahin, Mehmet Özgür; Saxena, Pooja; Schoerner-Sadenius, Thomas; Schröder, Matthias; Seitz, Claudia; Spannagel, Simon; Trippkewitz, Karim Damun; Walsh, Roberval; Wissing, Christoph; Blobel, Volker; Centis Vignali, Matteo; Draeger, Arne-Rasmus; Erfle, Joachim; Garutti, Erika; Goebel, Kristin; Gonzalez, Daniel; Görner, Martin; Haller, Johannes; Hoffmann, Malte; Höing, Rebekka Sophie; Junkes, Alexandra; Klanner, Robert; Kogler, Roman; Kovalchuk, Nataliia; Lapsien, Tobias; Lenz, Teresa; Marchesini, Ivan; Marconi, Daniele; Meyer, Mareike; Nowatschin, Dominik; Ott, Jochen; Pantaleo, Felice; Peiffer, Thomas; Perieanu, Adrian; Pietsch, Niklas; Poehlsen, Jennifer; Rathjens, Denis; Sander, Christian; Scharf, Christian; Schettler, Hannes; Schleper, Peter; Schlieckau, Eike; Schmidt, Alexander; Schwandt, Joern; Sola, Valentina; Stadie, Hartmut; Steinbrück, Georg; Tholen, Heiner; Troendle, Daniel; Usai, Emanuele; Vanelderen, Lukas; Vanhoefer, Annika; Vormwald, Benedikt; Barth, Christian; Baus, Colin; Berger, Joram; Böser, Christian; Butz, Erik; Chwalek, Thorsten; Colombo, Fabio; De Boer, Wim; Descroix, Alexis; Dierlamm, Alexander; Fink, Simon; Frensch, Felix; Friese, Raphael; Giffels, Manuel; Gilbert, Andrew; Haitz, Dominik; Hartmann, Frank; Heindl, Stefan Michael; Husemann, Ulrich; Katkov, Igor; Kornmayer, Andreas; Lobelle Pardo, Patricia; Maier, Benedikt; Mildner, Hannes; Mozer, Matthias Ulrich; Müller, Thomas; Müller, Thomas; Plagge, Michael; Quast, Gunter; Rabbertz, Klaus; Röcker, Steffen; Roscher, Frank; Sieber, Georg; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Ulrich, Ralf; Wagner-Kuhr, Jeannine; Wayand, Stefan; Weber, Marc; Weiler, Thomas; Williamson, Shawn; Wöhrmann, Clemens; Wolf, Roger; Anagnostou, Georgios; Daskalakis, Georgios; Geralis, Theodoros; Giakoumopoulou, Viktoria Athina; Kyriakis, Aristotelis; Loukas, Demetrios; Psallidas, Andreas; Topsis-Giotis, Iasonas; Agapitos, Antonis; Kesisoglou, Stilianos; Panagiotou, Apostolos; Saoulidou, Niki; Tziaferi, Eirini; Evangelou, Ioannis; Flouris, Giannis; Foudas, Costas; Kokkas, Panagiotis; Loukas, Nikitas; Manthos, Nikolaos; Papadopoulos, Ioannis; Paradas, Evangelos; Strologas, John; Bencze, Gyorgy; Hajdu, Csaba; Hazi, Andras; Hidas, Pàl; Horvath, Dezso; Sikler, Ferenc; Veszpremi, Viktor; Vesztergombi, Gyorgy; Zsigmond, Anna Julia; Beni, Noemi; Czellar, Sandor; Karancsi, János; Molnar, Jozsef; Szillasi, Zoltan; Bartók, Márton; Makovec, Alajos; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Mal, Prolay; Mandal, Koushik; Sahoo, Deepak Kumar; Sahoo, Niladribihari; Swain, Sanjay Kumar; Bansal, Sunil; Beri, Suman Bala; Bhatnagar, Vipin; Chawla, Ridhi; Gupta, Ruchi; Bhawandeep, Bhawandeep; Kalsi, Amandeep Kaur; Kaur, Anterpreet; Kaur, Manjit; Kumar, Ramandeep; Mehta, Ankita; Mittal, Monika; Singh, Jasbir; Walia, Genius; Kumar, Ashok; Bhardwaj, Ashutosh; Choudhary, Brajesh C; Garg, Rocky Bala; Kumar, Ajay; Malhotra, Shivali; Naimuddin, Md; Nishu, Nishu; Ranjan, Kirti; Sharma, Ramkrishna; Sharma, Varun; Bhattacharya, Satyaki; Chatterjee, Kalyanmoy; Dey, Sourav; Dutta, Suchandra; Jain, Sandhya; Majumdar, Nayana; Modak, Atanu; Mondal, Kuntal; Mukherjee, Swagata; Mukhopadhyay, Supratik; Roy, Ashim; Roy, Debarati; Roy Chowdhury, Suvankar; Sarkar, Subir; Sharan, Manoj; Abdulsalam, Abdulla; Chudasama, Ruchi; Dutta, Dipanwita; Jha, Vishwajeet; Kumar, Vineet; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Topkar, Anita; Aziz, Tariq; Banerjee, Sudeshna; Bhowmik, Sandeep; Chatterjee, Rajdeep Mohan; Dewanjee, Ram Krishna; Dugad, Shashikant; Ganguly, Sanmay; Ghosh, Saranya; Guchait, Monoranjan; Gurtu, Atul; Kole, Gouranga; Kumar, Sanjeev; Mahakud, Bibhuprasad; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mitra, Soureek; Mohanty, Gagan Bihari; Parida, Bibhuti; Sarkar, Tanmay; Sur, Nairit; Sutar, Bajrang; Wickramage, Nadeesha; Chauhan, Shubhanshu; Dube, Sourabh; Kapoor, Anshul; Kothekar, Kunal; Sharma, Seema; Bakhshiansohi, Hamed; Behnamian, Hadi; Etesami, Seyed Mohsen; Fahim, Ali; Goldouzian, Reza; Khakzad, Mohsen; Mohammadi Najafabadi, Mojtaba; Naseri, Mohsen; Paktinat Mehdiabadi, Saeid; Rezaei Hosseinabadi, Ferdos; Safarzadeh, Batool; Zeinali, Maryam; Felcini, Marta; Grunewald, Martin; Abbrescia, Marcello; Calabria, Cesare; Caputo, Claudio; Colaleo, Anna; Creanza, Donato; Cristella, Leonardo; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Maggi, Giorgio; Maggi, Marcello; Miniello, Giorgia; My, Salvatore; Nuzzo, Salvatore; Pompili, Alexis; Pugliese, Gabriella; Radogna, Raffaella; Ranieri, Antonio; Selvaggi, Giovanna; Silvestris, Lucia; Venditti, Rosamaria; Verwilligen, Piet; Abbiendi, Giovanni; Battilana, Carlo; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Campanini, Renato; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Chhibra, Simranjit Singh; Codispoti, Giuseppe; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Grandi, Claudio; Guiducci, Luigi; Marcellini, Stefano; Masetti, Gianni; Montanari, Alessandro; Navarria, Francesco; Perrotta, Andrea; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gian Piero; Tosi, Nicolò; Travaglini, Riccardo; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Di Mattia, Alessandro; Giordano, Ferdinando; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Gonzi, Sandro; Gori, Valentina; Lenzi, Piergiulio; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Viliani, Lorenzo; Benussi, Luigi; Bianco, Stefano; Fabbri, Franco; Piccolo, Davide; Primavera, Federica; Calvelli, Valerio; Ferro, Fabrizio; Lo Vetere, Maurizio; Monge, Maria Roberta; Robutti, Enrico; Tosi, Silvano; Brianza, Luca; Dinardo, Mauro Emanuele; Fiorendi, Sara; Gennai, Simone; Gerosa, Raffaele; Ghezzi, Alessio; Govoni, Pietro; Malvezzi, Sandra; Manzoni, Riccardo Andrea; Marzocchi, Badder; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Cavallo, Nicola; Di Guida, Salvatore; Esposito, Marco; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lanza, Giuseppe; Lista, Luca; Meola, Sabino; Merola, Mario; Paolucci, Pierluigi; Sciacca, Crisostomo; Thyssen, Filip; Azzi, Patrizia; Bacchetta, Nicola; Benato, Lisa; Bisello, Dario; Boletti, Alessio; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; Dall'Osso, Martino; Dorigo, Tommaso; Dosselli, Umberto; Fantinel, Sergio; Fanzago, Federica; Gasparini, Fabrizio; Gasparini, Ugo; Gozzelino, Andrea; Kanishchev, Konstantin; Lacaprara, Stefano; Margoni, Martino; Meneguzzo, Anna Teresa; Pazzini, Jacopo; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Zanetti, Marco; Zotto, Pierluigi; Zucchetta, Alberto; Braghieri, Alessandro; Magnani, Alice; Montagna, Paolo; Ratti, Sergio P; Re, Valerio; Riccardi, Cristina; Salvini, Paola; Vai, Ilaria; Vitulo, Paolo; Alunni Solestizi, Luisa; Bilei, Gian Mario; Ciangottini, Diego; Fanò, Livio; Lariccia, Paolo; Mantovani, Giancarlo; Menichelli, Mauro; Saha, Anirban; Santocchia, Attilio; Androsov, Konstantin; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Castaldi, Rino; Ciocci, Maria Agnese; Dell'Orso, Roberto; Donato, Silvio; Fedi, Giacomo; Foà, Lorenzo; Giassi, Alessandro; Grippo, Maria Teresa; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Rizzi, Andrea; Savoy-Navarro, Aurore; Serban, Alin Titus; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; D'imperio, Giulia; Del Re, Daniele; Diemoz, Marcella; Gelli, Simone; Jorda, Clara; Longo, Egidio; Margaroli, Fabrizio; Meridiani, Paolo; Organtini, Giovanni; Paramatti, Riccardo; Preiato, Federico; Rahatlou, Shahram; Rovelli, Chiara; Santanastasio, Francesco; Traczyk, Piotr; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Bellan, Riccardo; Biino, Cristina; Cartiglia, Nicolo; Costa, Marco; Covarelli, Roberto; Degano, Alessandro; Demaria, Natale; Finco, Linda; Kiani, Bilal; Mariotti, Chiara; Maselli, Silvia; Migliore, Ernesto; Monaco, Vincenzo; Monteil, Ennio; Obertino, Maria Margherita; Pacher, Luca; Pastrone, Nadia; Pelliccioni, Mario; Pinna Angioni, Gian Luca; Ravera, Fabio; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Solano, Ada; Staiano, Amedeo; Belforte, Stefano; Candelise, Vieri; Casarsa, Massimo; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; La Licata, Chiara; Marone, Matteo; Schizzi, Andrea; Zanetti, Anna; Kropivnitskaya, Anna; Nam, Soon-Kwon; Kim, Dong Hee; Kim, Gui Nyun; Kim, Min Suk; Kong, Dae Jung; Lee, Sangeun; Oh, Young Do; Sakharov, Alexandre; Son, Dong-Chul; Brochero Cifuentes, Javier Andres; Kim, Hyunsoo; Kim, Tae Jeong; Song, Sanghyeon; Choi, Suyong; Go, Yeonju; Gyun, Dooyeon; Hong, Byung-Sik; Kim, Hyunchul; Kim, Yongsun; Lee, Byounghoon; Lee, Kisoo; Lee, Kyong Sei; Lee, Songkyo; Park, Sung Keun; Roh, Youn; Yoo, Hwi Dong; Choi, Minkyoo; Kim, Hyunyong; Kim, Ji Hyun; Lee, Jason Sang Hun; Park, Inkyu; Ryu, Geonmo; Ryu, Min Sang; Choi, Young-Il; Goh, Junghwan; Kim, Donghyun; Kwon, Eunhyang; Lee, Jongseok; Yu, Intae; Dudenas, Vytautas; Juodagalvis, Andrius; Vaitkus, Juozas; Ahmed, Ijaz; Ibrahim, Zainol Abidin; Komaragiri, Jyothsna Rani; Md Ali, Mohd Adli Bin; Mohamad Idris, Faridah; Wan Abdullah, Wan Ahmad Tajuddin; Yusli, Mohd Nizam; Casimiro Linares, Edgar; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-De La Cruz, Ivan; Hernandez-Almada, Alberto; Lopez-Fernandez, Ricardo; Sánchez Hernández, Alberto; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Pedraza, Isabel; Salazar Ibarguen, Humberto Antonio; Morelos Pineda, Antonio; Krofcheck, David; Butler, Philip H; Ahmad, Ashfaq; Ahmad, Muhammad; Hassan, Qamar; Hoorani, Hafeez R; Khan, Wajid Ali; Khurshid, Taimoor; Shoaib, Muhammad; Bialkowska, Helena; Bluj, Michal; Boimska, Bożena; Frueboes, Tomasz; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Zalewski, Piotr; Brona, Grzegorz; Bunkowski, Karol; Byszuk, Adrian; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Misiura, Maciej; Olszewski, Michal; Walczak, Marek; Bargassa, Pedrame; Beirão Da Cruz E Silva, Cristóvão; Di Francesco, Agostino; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Leonardo, Nuno; Lloret Iglesias, Lara; Nguyen, Federico; Rodrigues Antunes, Joao; Seixas, Joao; Toldaiev, Oleksii; Vadruccio, Daniele; Varela, Joao; Vischia, Pietro; Afanasiev, Serguei; Bunin, Pavel; Gavrilenko, Mikhail; Golutvin, Igor; Gorbunov, Ilya; Kamenev, Alexey; Karjavin, Vladimir; Konoplyanikov, Viktor; Lanev, Alexander; Malakhov, Alexander; Matveev, Viktor; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Shmatov, Sergey; Shulha, Siarhei; Skatchkov, Nikolai; Smirnov, Vitaly; Zarubin, Anatoli; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Kuznetsova, Ekaterina; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Karneyeu, Anton; Kirsanov, Mikhail; Krasnikov, Nikolai; Pashenkov, Anatoli; Tlisov, Danila; Toropin, Alexander; Epshteyn, Vladimir; Gavrilov, Vladimir; Lychkovskaya, Natalia; Popov, Vladimir; Pozdnyakov, Ivan; Safronov, Grigory; Spiridonov, Alexander; Vlasov, Evgueni; Zhokin, Alexander; Bylinkin, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Mesyats, Gennady; Rusakov, Sergey V; Baskakov, Alexey; Belyaev, Andrey; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Klyukhin, Vyacheslav; Kodolova, Olga; Lokhtin, Igor; Miagkov, Igor; Obraztsov, Stepan; Petrushanko, Sergey; Savrin, Viktor; Snigirev, Alexander; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Kachanov, Vassili; Kalinin, Alexey; Konstantinov, Dmitri; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Cirkovic, Predrag; Milosevic, Jovan; Rekovic, Vladimir; Alcaraz Maestre, Juan; Calvo, Enrique; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Escalante Del Valle, Alberto; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Navarro De Martino, Eduardo; Pérez-Calero Yzquierdo, Antonio María; Puerta Pelayo, Jesus; Quintario Olmeda, Adrián; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Albajar, Carmen; de Trocóniz, Jorge F; Missiroli, Marino; Moran, Dermot; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Palencia Cortezon, Enrique; Vizan Garcia, Jesus Manuel; Cabrillo, Iban Jose; Calderon, Alicia; Castiñeiras De Saa, Juan Ramon; De Castro Manzano, Pablo; Fernandez, Marcos; Garcia-Ferrero, Juan; Gomez, Gervasio; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Piedra Gomez, Jonatan; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Trevisani, Nicolò; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Bachtis, Michail; Baillon, Paul; Ball, Austin; Barney, David; Benaglia, Andrea; Bendavid, Joshua; Benhabib, Lamia; Benitez, Jose F; Berruti, Gaia Maria; Bloch, Philippe; Bocci, Andrea; Bonato, Alessio; Botta, Cristina; Breuker, Horst; Camporesi, Tiziano; Castello, Roberto; Cerminara, Gianluca; D'Alfonso, Mariarosaria; D'Enterria, David; Dabrowski, Anne; Daponte, Vincenzo; David Tinoco Mendes, Andre; De Gruttola, Michele; De Guio, Federico; De Roeck, Albert; De Visscher, Simon; Di Marco, Emanuele; Dobson, Marc; Dordevic, Milos; Dorney, Brian; Du Pree, Tristan; Duggan, Daniel; Dünser, Marc; Dupont, Niels; Elliott-Peisert, Anna; Franzoni, Giovanni; Fulcher, Jonathan; Funk, Wolfgang; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Girone, Maria; Glege, Frank; Guida, Roberto; Gundacker, Stefan; Guthoff, Moritz; Hammer, Josef; Harris, Philip; Hegeman, Jeroen; Innocente, Vincenzo; Janot, Patrick; Kirschenmann, Henning; Kortelainen, Matti J; Kousouris, Konstantinos; Krajczar, Krisztian; Lecoq, Paul; Lourenco, Carlos; Lucchini, Marco Toliman; Magini, Nicolo; Malgeri, Luca; Mannelli, Marcello; Martelli, Arabella; Masetti, Lorenzo; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moortgat, Filip; Morovic, Srecko; Mulders, Martijn; Nemallapudi, Mythra Varun; Neugebauer, Hannes; Orfanelli, Styliani; Orsini, Luciano; Pape, Luc; Perez, Emmanuelle; Peruzzi, Marco; Petrilli, Achille; Petrucciani, Giovanni; Pfeiffer, Andreas; Piparo, Danilo; Racz, Attila; Reis, Thomas; Rolandi, Gigi; Rovere, Marco; Ruan, Manqi; Sakulin, Hannes; Schäfer, Christoph; Schwick, Christoph; Seidel, Markus; Sharma, Archana; Silva, Pedro; Simon, Michal; Sphicas, Paraskevas; Steggemann, Jan; Stieger, Benjamin; Stoye, Markus; Takahashi, Yuta; Treille, Daniel; Triossi, Andrea; Tsirou, Andromachi; Veres, Gabor Istvan; Wardle, Nicholas; Wöhri, Hermine Katharina; Zagoździńska, Agnieszka; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; Kotlinski, Danek; Langenegger, Urs; Renker, Dieter; Rohe, Tilman; Bachmair, Felix; Bäni, Lukas; Bianchini, Lorenzo; Casal, Bruno; Dissertori, Günther; Dittmar, Michael; Donegà, Mauro; Eller, Philipp; Grab, Christoph; Heidegger, Constantin; Hits, Dmitry; Hoss, Jan; Kasieczka, Gregor; Lustermann, Werner; Mangano, Boris; Marionneau, Matthieu; Martinez Ruiz del Arbol, Pablo; Masciovecchio, Mario; Meister, Daniel; Micheli, Francesco; Musella, Pasquale; Nessi-Tedaldi, Francesca; Pandolfi, Francesco; Pata, Joosep; Pauss, Felicitas; Perrozzi, Luca; Quittnat, Milena; Rossini, Marco; Starodumov, Andrei; Takahashi, Maiko; Tavolaro, Vittorio Raoul; Theofilatos, Konstantinos; Wallny, Rainer; Aarrestad, Thea Klaeboe; Amsler, Claude; Caminada, Lea; Canelli, Maria Florencia; Chiochia, Vincenzo; De Cosa, Annapaola; Galloni, Camilla; Hinzmann, Andreas; Hreus, Tomas; Kilminster, Benjamin; Lange, Clemens; Ngadiuba, Jennifer; Pinna, Deborah; Robmann, Peter; Ronga, Frederic Jean; Salerno, Daniel; Yang, Yong; Cardaci, Marco; Chen, Kuan-Hsin; Doan, Thi Hien; Jain, Shilpi; Khurana, Raman; Konyushikhin, Maxim; Kuo, Chia-Ming; Lin, Willis; Lu, Yun-Ju; Yu, Shin-Shan; Kumar, Arun; Bartek, Rachel; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Chen, Po-Hsun; Dietz, Charles; Fiori, Francesco; Grundler, Ulysses; Hou, George Wei-Shu; Hsiung, Yee; Liu, Yueh-Feng; Lu, Rong-Shyang; Miñano Moya, Mercedes; Petrakou, Eleni; Tsai, Jui-fa; Tzeng, Yeng-Ming; Asavapibhop, Burin; Kovitanggoon, Kittikul; Singh, Gurpreet; Srimanobhas, Norraphat; Suwonjandee, Narumon; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Demiroglu, Zuhal Seyma; Dozen, Candan; Eskut, Eda; Gecit, Fehime Hayal; Girgis, Semiray; Gokbulut, Gul; Guler, Yalcin; Gurpinar, Emine; Hos, Ilknur; Kangal, Evrim Ersin; Onengut, Gulsen; Ozcan, Merve; Ozdemir, Kadri; Polatoz, Ayse; Sunar Cerci, Deniz; Topakli, Huseyin; Vergili, Mehmet; Zorbilmez, Caglar; Akin, Ilina Vasileva; Bilin, Bugra; Bilmis, Selcuk; Isildak, Bora; Karapinar, Guler; Yalvac, Metin; Zeyrek, Mehmet; Gülmez, Erhan; Kaya, Mithat; Kaya, Ozlem; Yetkin, Elif Asli; Yetkin, Taylan; Cakir, Altan; Cankocak, Kerem; Sen, Sercan; Vardarlı, Fuat Ilkehan; Grynyov, Boris; Levchuk, Leonid; Sorokin, Pavel; Aggleton, Robin; Ball, Fionn; Beck, Lana; Brooke, James John; Clement, Emyr; Cussans, David; Flacher, Henning; Goldstein, Joel; Grimes, Mark; Heath, Greg P; Heath, Helen F; Jacob, Jeson; Kreczko, Lukasz; Lucas, Chris; Meng, Zhaoxia; Newbold, Dave M; Paramesvaran, Sudarshan; Poll, Anthony; Sakuma, Tai; Seif El Nasr-storey, Sarah; Senkin, Sergey; Smith, Dominic; Smith, Vincent J; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Calligaris, Luigi; Cieri, Davide; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Olaiya, Emmanuel; Petyt, David; Shepherd-Themistocleous, Claire; Thea, Alessandro; Tomalin, Ian R; Williams, Thomas; Worm, Steven; Baber, Mark; Bainbridge, Robert; Buchmuller, Oliver; Bundock, Aaron; Burton, Darren; Casasso, Stefano; Citron, Matthew; Colling, David; Corpe, Louie; Cripps, Nicholas; Dauncey, Paul; Davies, Gavin; De Wit, Adinda; Della Negra, Michel; Dunne, Patrick; Elwood, Adam; Ferguson, William; Futyan, David; Hall, Geoffrey; Iles, Gregory; Kenzie, Matthew; Lane, Rebecca; Lucas, Robyn; Lyons, Louis; Magnan, Anne-Marie; Malik, Sarah; Nash, Jordan; Nikitenko, Alexander; Pela, Joao; Pesaresi, Mark; Petridis, Konstantinos; Raymond, David Mark; Richards, Alexander; Rose, Andrew; Seez, Christopher; Tapper, Alexander; Uchida, Kirika; Vazquez Acosta, Monica; Virdee, Tejinder; Zenz, Seth Conrad; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leggat, Duncan; Leslie, Dawn; Reid, Ivan; Symonds, Philip; Teodorescu, Liliana; Turner, Mark; Borzou, Ahmad; Call, Kenneth; Dittmann, Jay; Hatakeyama, Kenichi; Liu, Hongxuan; Pastika, Nathaniel; Charaf, Otman; Cooper, Seth; Henderson, Conor; Rumerio, Paolo; Arcaro, Daniel; Avetisyan, Aram; Bose, Tulika; Fantasia, Cory; Gastler, Daniel; Lawson, Philip; Rankin, Dylan; Richardson, Clint; Rohlf, James; St John, Jason; Sulak, Lawrence; Zou, David; Alimena, Juliette; Berry, Edmund; Bhattacharya, Saptaparna; Cutts, David; Dhingra, Nitish; Ferapontov, Alexey; Garabedian, Alex; Hakala, John; Heintz, Ulrich; Laird, Edward; Landsberg, Greg; Mao, Zaixing; Narain, Meenakshi; Piperov, Stefan; Sagir, Sinan; Syarif, Rizki; Breedon, Richard; Breto, Guillermo; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Conway, Rylan; Cox, Peter Timothy; Erbacher, Robin; Funk, Garrett; Gardner, Michael; Ko, Winston; Lander, Richard; Mulhearn, Michael; Pellett, Dave; Pilot, Justin; Ricci-Tam, Francesca; Shalhout, Shalhout; Smith, John; Squires, Michael; Stolp, Dustin; Tripathi, Mani; Wilbur, Scott; Yohay, Rachel; Bravo, Cameron; Cousins, Robert; Everaerts, Pieter; Farrell, Chris; Florent, Alice; Hauser, Jay; Ignatenko, Mikhail; Saltzberg, David; Schnaible, Christian; Takasugi, Eric; Valuev, Vyacheslav; Weber, Matthias; Burt, Kira; Clare, Robert; Ellison, John Anthony; Gary, J William; Hanson, Gail; Heilman, Jesse; Ivova PANEVA, Mirena; Jandir, Pawandeep; Kennedy, Elizabeth; Lacroix, Florent; Long, Owen Rosser; Luthra, Arun; Malberti, Martina; Olmedo Negrete, Manuel; Shrinivas, Amithabh; Wei, Hua; Wimpenny, Stephen; Yates, Brent; Branson, James G; Cerati, Giuseppe Benedetto; Cittolin, Sergio; D'Agnolo, Raffaele Tito; Derdzinski, Mark; Holzner, André; Kelley, Ryan; Klein, Daniel; Letts, James; Macneill, Ian; Olivito, Dominick; Padhi, Sanjay; Pieri, Marco; Sani, Matteo; Sharma, Vivek; Simon, Sean; Tadel, Matevz; Vartak, Adish; Wasserbaech, Steven; Welke, Charles; Würthwein, Frank; Yagil, Avraham; Zevi Della Porta, Giovanni; Bradmiller-Feld, John; Campagnari, Claudio; Dishaw, Adam; Dutta, Valentina; Flowers, Kristen; Franco Sevilla, Manuel; Geffert, Paul; George, Christopher; Golf, Frank; Gouskos, Loukas; Gran, Jason; Incandela, Joe; Mccoll, Nickolas; Mullin, Sam Daniel; Richman, Jeffrey; Stuart, David; Suarez, Indara; West, Christopher; Yoo, Jaehyeok; Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; Bunn, Julian; Chen, Yi; Duarte, Javier; Mott, Alexander; Newman, Harvey B; Pena, Cristian; Pierini, Maurizio; Spiropulu, Maria; Vlimant, Jean-Roch; Xie, Si; Zhu, Ren-Yuan; Andrews, Michael Benjamin; Azzolini, Virginia; Calamba, Aristotle; Carlson, Benjamin; Ferguson, Thomas; Paulini, Manfred; Russ, James; Sun, Menglei; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Ford, William T; Gaz, Alessandro; Jensen, Frank; Johnson, Andrew; Krohn, Michael; Mulholland, Troy; Nauenberg, Uriel; Stenson, Kevin; Wagner, Stephen Robert; Alexander, James; Chatterjee, Avishek; Chaves, Jorge; Chu, Jennifer; Dittmer, Susan; Eggert, Nicholas; Mirman, Nathan; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Rinkevicius, Aurelijus; Ryd, Anders; Skinnari, Louise; Soffi, Livia; Sun, Werner; Tan, Shao Min; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Tucker, Jordan; Weng, Yao; Wittich, Peter; Abdullin, Salavat; Albrow, Michael; Apollinari, Giorgio; Banerjee, Sunanda; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bolla, Gino; Burkett, Kevin; Butler, Joel Nathan; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Elvira, Victor Daniel; Fisk, Ian; Freeman, Jim; Gottschalk, Erik; Gray, Lindsey; Green, Dan; Grünendahl, Stefan; Gutsche, Oliver; Hanlon, Jim; Hare, Daryl; Harris, Robert M; Hasegawa, Satoshi; Hirschauer, James; Hu, Zhen; Jayatilaka, Bodhitha; Jindariani, Sergo; Johnson, Marvin; Joshi, Umesh; Jung, Andreas Werner; Klima, Boaz; Kreis, Benjamin; Lammel, Stephan; Linacre, Jacob; Lincoln, Don; Lipton, Ron; Liu, Tiehui; Lopes De Sá, Rafael; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Martinez Outschoorn, Verena Ingrid; Maruyama, Sho; Mason, David; McBride, Patricia; Merkel, Petra; Mishra, Kalanand; Mrenna, Stephen; Nahn, Steve; Newman-Holmes, Catherine; O'Dell, Vivian; Pedro, Kevin; Prokofyev, Oleg; Rakness, Gregory; Sexton-Kennedy, Elizabeth; Soha, Aron; Spalding, William J; Spiegel, Leonard; Strobbe, Nadja; Taylor, Lucas; Tkaczyk, Slawek; Tran, Nhan Viet; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vernieri, Caterina; Verzocchi, Marco; Vidal, Richard; Weber, Hannsjoerg Artur; Whitbeck, Andrew; Acosta, Darin; Avery, Paul; Bortignon, Pierluigi; Bourilkov, Dimitri; Carnes, Andrew; Carver, Matthew; Curry, David; Das, Souvik; Field, Richard D; Furic, Ivan-Kresimir; Gleyzer, Sergei V; Hugon, Justin; Konigsberg, Jacobo; Korytov, Andrey; Kotov, Khristian; Low, Jia Fu; Ma, Peisen; Matchev, Konstantin; Mei, Hualin; Milenovic, Predrag; Mitselmakher, Guenakh; Rank, Douglas; Rossin, Roberto; Shchutska, Lesya; Snowball, Matthew; Sperka, David; Terentyev, Nikolay; Thomas, Laurent; Wang, Jian; Wang, Sean-Jiun; Yelton, John; Hewamanage, Samantha; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Ackert, Andrew; Adams, Jordon Rowe; Adams, Todd; Askew, Andrew; Bein, Samuel; Bochenek, Joseph; Diamond, Brendan; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Khatiwada, Ajeeta; Prosper, Harrison; Weinberg, Marc; Baarmand, Marc M; Bhopatkar, Vallary; Colafranceschi, Stefano; Hohlmann, Marcus; Kalakhety, Himali; Noonan, Daniel; Roy, Titas; Yumiceva, Francisco; Adams, Mark Raymond; Apanasevich, Leonard; Berry, Douglas; Betts, Russell Richard; Bucinskaite, Inga; Cavanaugh, Richard; Evdokimov, Olga; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Kurt, Pelin; O'Brien, Christine; Sandoval Gonzalez, Irving Daniel; Silkworth, Christopher; Turner, Paul; Varelas, Nikos; Wu, Zhenbin; Zakaria, Mohammed; Bilki, Burak; Clarida, Warren; Dilsiz, Kamuran; Durgut, Süleyman; Gandrajula, Reddy Pratap; Haytmyradov, Maksat; Khristenko, Viktor; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Ogul, Hasan; Onel, Yasar; Ozok, Ferhat; Penzo, Aldo; Snyder, Christina; Tiras, Emrah; Wetzel, James; Yi, Kai; Anderson, Ian; Barnett, Bruce Arnold; Blumenfeld, Barry; Eminizer, Nicholas; Fehling, David; Feng, Lei; Gritsan, Andrei; Maksimovic, Petar; Martin, Christopher; Osherson, Marc; Roskes, Jeffrey; Cocoros, Alice; Sarica, Ulascan; Swartz, Morris; Xiao, Meng; Xin, Yongjie; You, Can; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Bruner, Christopher; Kenny III, Raymond Patrick; Majumder, Devdatta; Malek, Magdalena; Murray, Michael; Sanders, Stephen; Stringer, Robert; Wang, Quan; Ivanov, Andrew; Kaadze, Ketino; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Mohammadi, Abdollah; Saini, Lovedeep Kaur; Skhirtladze, Nikoloz; Toda, Sachiko; Lange, David; Rebassoo, Finn; Wright, Douglas; Anelli, Christopher; Baden, Drew; Baron, Owen; Belloni, Alberto; Calvert, Brian; Eno, Sarah Catherine; Ferraioli, Charles; Gomez, Jaime; Hadley, Nicholas John; Jabeen, Shabnam; Kellogg, Richard G; Kolberg, Ted; Kunkle, Joshua; Lu, Ying; Mignerey, Alice; Shin, Young Ho; Skuja, Andris; Tonjes, Marguerite; Tonwar, Suresh C; Apyan, Aram; Barbieri, Richard; Baty, Austin; Bierwagen, Katharina; Brandt, Stephanie; Busza, Wit; Cali, Ivan Amos; Demiragli, Zeynep; Di Matteo, Leonardo; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Gulhan, Doga; Iiyama, Yutaro; Innocenti, Gian Michele; Klute, Markus; Kovalskyi, Dmytro; Lai, Yue Shi; Lee, Yen-Jie; Levin, Andrew; Luckey, Paul David; Marini, Andrea Carlo; Mcginn, Christopher; Mironov, Camelia; Narayanan, Siddharth; Niu, Xinmei; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Salfeld-Nebgen, Jakob; Stephans, George; Sumorok, Konstanty; Varma, Mukund; Velicanu, Dragos; Veverka, Jan; Wang, Jing; Wang, Ta-Wei; Wyslouch, Bolek; Yang, Mingming; Zhukova, Victoria; Dahmes, Bryan; Evans, Andrew; Finkel, Alexey; Gude, Alexander; Hansen, Peter; Kalafut, Sean; Kao, Shih-Chuan; Klapoetke, Kevin; Kubota, Yuichi; Lesko, Zachary; Mans, Jeremy; Nourbakhsh, Shervin; Ruckstuhl, Nicole; Rusack, Roger; Tambe, Norbert; Turkewitz, Jared; Acosta, John Gabriel; Oliveros, Sandra; Avdeeva, Ekaterina; Bloom, Kenneth; Bose, Suvadeep; Claes, Daniel R; Dominguez, Aaron; Fangmeier, Caleb; Gonzalez Suarez, Rebeca; Kamalieddin, Rami; Keller, Jason; Knowlton, Dan; Kravchenko, Ilya; Meier, Frank; Monroy, Jose; Ratnikov, Fedor; Siado, Joaquin Emilo; Snow, Gregory R; Alyari, Maral; Dolen, James; George, Jimin; Godshalk, Andrew; Harrington, Charles; Iashvili, Ia; Kaisen, Josh; Kharchilava, Avto; Kumar, Ashish; Rappoccio, Salvatore; Roozbahani, Bahareh; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Chasco, Matthew; Hortiangtham, Apichart; Massironi, Andrea; Morse, David Michael; Nash, David; Orimoto, Toyoko; Teixeira De Lima, Rafael; Trocino, Daniele; Wang, Ren-Jie; Wood, Darien; Zhang, Jinzhong; Hahn, Kristan Allan; Kubik, Andrew; Mucia, Nicholas; Odell, Nathaniel; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Sung, Kevin; Trovato, Marco; Velasco, Mayda; Brinkerhoff, Andrew; Dev, Nabarun; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kellams, Nathan; Lannon, Kevin; Marinelli, Nancy; Meng, Fanbo; Mueller, Charles; Musienko, Yuri; Planer, Michael; Reinsvold, Allison; Ruchti, Randy; Smith, Geoffrey; Taroni, Silvia; Valls, Nil; Wayne, Mitchell; Wolf, Matthias; Woodard, Anna; Antonelli, Louis; Brinson, Jessica; Bylsma, Ben; Durkin, Lloyd Stanley; Flowers, Sean; Hart, Andrew; Hill, Christopher; Hughes, Richard; Ji, Weifeng; Ling, Ta-Yung; Liu, Bingxuan; Luo, Wuming; Puigh, Darren; Rodenburg, Marissa; Winer, Brian L; Wulsin, Howard Wells; Driga, Olga; Elmer, Peter; Hardenbrook, Joshua; Hebda, Philip; Koay, Sue Ann; Lujan, Paul; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Palmer, Christopher; Piroué, Pierre; Saka, Halil; Stickland, David; Tully, Christopher; Zuranski, Andrzej; Malik, Sudhir; Barnes, Virgil E; Benedetti, Daniele; Bortoletto, Daniela; Gutay, Laszlo; Jha, Manoj; Jones, Matthew; Jung, Kurt; Miller, David Harry; Neumeister, Norbert; Radburn-Smith, Benjamin Charles; Shi, Xin; Shipsey, Ian; Silvers, David; Sun, Jian; Svyatkovskiy, Alexey; Wang, Fuqiang; Xie, Wei; Xu, Lingshan; Parashar, Neeti; Stupak, John; Adair, Antony; Akgun, Bora; Chen, Zhenyu; Ecklund, Karl Matthew; Geurts, Frank JM; Guilbaud, Maxime; Li, Wei; Michlin, Benjamin; Northup, Michael; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Rorie, Jamal; Tu, Zhoudunming; Zabel, James; Betchart, Burton; Bodek, Arie; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Ferbel, Thomas; Galanti, Mario; Garcia-Bellido, Aran; Han, Jiyeon; Harel, Amnon; Hindrichs, Otto; Khukhunaishvili, Aleko; Petrillo, Gianluca; Tan, Ping; Verzetti, Mauro; Arora, Sanjay; Barker, Anthony; Chou, John Paul; Contreras-Campana, Christian; Contreras-Campana, Emmanuel; Ferencek, Dinko; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hughes, Elliot; Kaplan, Steven; Kunnawalkam Elayavalli, Raghav; Lath, Amitabh; Nash, Kevin; Panwalkar, Shruti; Park, Michael; Salur, Sevil; Schnetzer, Steve; Sheffield, David; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Thomassen, Peter; Walker, Matthew; Foerster, Mark; Riley, Grant; Rose, Keith; Spanier, Stefan; York, Andrew; Bouhali, Othmane; Castaneda Hernandez, Alfredo; Celik, Ali; Dalchenko, Mykhailo; De Mattia, Marco; Delgado, Andrea; Dildick, Sven; Eusebi, Ricardo; Gilmore, Jason; Huang, Tao; Kamon, Teruki; Krutelyov, Vyacheslav; Mueller, Ryan; Osipenkov, Ilya; Pakhotin, Yuriy; Patel, Rishi; Perloff, Alexx; Rose, Anthony; Safonov, Alexei; Tatarinov, Aysen; Ulmer, Keith; Akchurin, Nural; Cowden, Christopher; Damgov, Jordan; Dragoiu, Cosmin; Dudero, Phillip Russell; Faulkner, James; Kunori, Shuichi; Lamichhane, Kamal; Lee, Sung Won; Libeiro, Terence; Undleeb, Sonaina; Volobouev, Igor; Appelt, Eric; Delannoy, Andrés G; Greene, Senta; Gurrola, Alfredo; Janjam, Ravi; Johns, Willard; Maguire, Charles; Mao, Yaxian; Melo, Andrew; Ni, Hong; Sheldon, Paul; Snook, Benjamin; Tuo, Shengquan; Velkovska, Julia; Xu, Qiao; Arenton, Michael Wayne; Cox, Bradley; Francis, Brian; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Li, Hengne; Lin, Chuanzhe; Neu, Christopher; Sinthuprasith, Tutanon; Sun, Xin; Wang, Yanchu; Wolfe, Evan; Wood, John; Xia, Fan; Clarke, Christopher; Harr, Robert; Karchin, Paul Edmund; Kottachchi Kankanamge Don, Chamath; Lamichhane, Pramod; Sturdy, Jared; Belknap, Donald; Carlsmith, Duncan; Cepeda, Maria; Dasu, Sridhara; Dodd, Laura; Duric, Senka; Gomber, Bhawna; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Lanaro, Armando; Levine, Aaron; Long, Kenneth; Loveless, Richard; Mohapatra, Ajit; Ojalvo, Isabel; Perry, Thomas; Pierro, Giuseppe Antonio; Polese, Giovanni; Ruggles, Tyler; Sarangi, Tapas; Savin, Alexander; Sharma, Archana; Smith, Nicholas; Smith, Wesley H; Taylor, Devin; Woods, Nathaniel

    2016-03-17

    New sets of parameters (``tunes'') for the underlying-event (UE) modeling of the PYTHIA8, PYTHIA6 and HERWIG++ Monte Carlo event generators are constructed using different parton distribution functions. Combined fits to CMS UE data at $\\sqrt{s} =$ 7 TeV and to UE data from the CDF experiment at lower $\\sqrt{s}$, are used to study the UE models and constrain their parameters, providing thereby improved predictions for proton-proton collisions at 13 TeV. In addition, it is investigated whether the values of the parameters obtained from fits to UE observables are consistent with the values determined from fitting observables sensitive to double-parton scattering processes. Finally, comparisons of the UE tunes to ``minimum bias'' (MB) events, multijet, and Drell--Yan ($ \\mathrm{ q \\bar{q} } \\rightarrow \\mathrm{Z} / \\gamma^* \\rightarrow$ lepton-antilepton + jets) observables at 7 and 8 TeV are presented, as well as predictions of MB and UE observables at 13 TeV.

  6. Constraining Saturn's interior density profile from precision gravity field measurement obtained during Grand Finale

    Science.gov (United States)

    Movshovitz, N.; Fortney, J. J.; Helled, R.; Hubbard, W. B.; Mankovich, C.; Thorngren, D.; Wahl, S. M.; Militzer, B.; Durante, D.

    2017-12-01

    The external gravity field of a planetary body is determined by the distribution of mass in its interior. Therefore, a measurement of the external field, properlyinterpreted, tells us about the interior density profile, ρ(r), which in turn can be used to constrain the composition in the interior and thereby learn about theformation mechanism of the planet. Recently, very high precision measurements of the gravity coefficients for Saturn have been made by the radio science instrument on the Cassini spacecraft during its Grand Finale orbits. The resulting coefficients come with an associated uncertainty. The task of matching a given density profile to a given set of gravity coefficients is relatively straightforward, but the question of how to best account for the uncertainty is not. In essentially all prior work on matching models to gravity field data inferences about planetary structure have rested on assumptions regarding the imperfectly known H/He equation of state and the assumption of an adiabatic interior. Here we wish to vastly expand the phase space of such calculations. We present a framework for describing all the possible interior density structures of a Jovian planet constrained by a given set of gravity coefficients and their associated uncertainties. Our approach is statistical. We produce a random sample of ρ(a) curves drawn from the underlying (and unknown) probability distribution of all curves, where ρ is the density on an interior level surface with equatorial radius a. Since the resulting set of density curves is a random sample, that is, curves appear with frequency proportional to the likelihood of their being consistent with the measured gravity, we can compute probability distributions for any quantity that is a function of ρ, such as central pressure, oblateness, core mass and radius, etc. Our approach is also Bayesian, in that it can utilize any prior assumptions about the planet's interior, as necessary, without being overly

  7. Latest results of SEE measurements obtained by the STRURED demonstrator ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Candelori, A. [INFN, Section of Padova, Via Marzolo 8, c.a.p. 35131, Padova (Italy); De Robertis, G. [INFN Section of Bari, Via Orabona 4, c.a.p. 70126, Bari (Italy); Gabrielli, A. [Physics Department, University of Bologna, Viale Berti Pichat 6/2, c.a.p. 40127, Bologna (Italy); Mattiazzo, S.; Pantano, D. [INFN, Section of Padova, Via Marzolo 8, c.a.p. 35131, Padova (Italy); Ranieri, A., E-mail: antonio.ranieri@ba.infn.i [INFN Section of Bari, Via Orabona 4, c.a.p. 70126, Bari (Italy); Tessaro, M. [INFN, Section of Padova, Via Marzolo 8, c.a.p. 35131, Padova (Italy)

    2011-01-21

    With the perspective to develop a radiation-tolerant circuit for High Energy Physics (HEP) applications, a test digital ASIC VLSI chip, called STRURED, has been designed and fabricated using a standard-cell library of commercial 130 nm CMOS technology by implementing three different radiation-tolerant architectures (Hamming, Triple Modular Redundancy and Triple Time Redundancy) in order to correct circuit malfunctions induced by the occurrence of Soft Errors (SEs). SEs are one of the main reasons of failures affecting electronic digital circuits operating in harsh radiation environments, such as in experiments performed at HEP colliders or in apparatus to be operated in space. In this paper we present and discuss the latest results of SE cross-section measurements performed using the STRURED digital device, exposed to high energy heavy ions at the SIRAD irradiation facility of the INFN National Laboratories of Legnaro (Padova, Italy). In particular the different behaviors of the input part and the core of the three radiation-tolerant architectures are analyzed in detail.

  8. Different conformational forms of serum carnosinase detected by a newly developed sandwich ELISA for the measurements of carnosinase concentrations

    NARCIS (Netherlands)

    Adelmann, Katja; Frey, Dirk; Riedl, Eva; Koeppel, Hannes; Pfister, Frederick; Peters, Verena; Schmitt, Claus P.; Sternik, Paula; Hofmann, Stephanie; Zentgraf, Hans Walter; Navis, Gerjan; van den Born, Jacob; Bakker, Stephan J. L.; Kraemer, Bernhard K.; Yard, Benito A.; Hauske, Sibylle J.

    Serum carnosinase (CN-1) measurements are at present mainly performed by assessing enzyme activity. This method is time-consuming, not well suited for large series of samples and can be discordant to measurements of CN-1 protein concentrations. To overcome these limitations, we developed sandwich

  9. Results of environmental radiation monitoring and meteorology measurements (material prepared for obtaining the licence for RA reactor experimental operation)

    International Nuclear Information System (INIS)

    1980-10-01

    According to the demands for obtaining the licence for restarting the Ra reactor and the experimental operation this document includes the radiation monitoring measured data in the working space and environment of the RA reactor, i.e. Boris Kidric Institute. The meteorology measured data are included as well. All the measurements are performed according to the radiation protection program applied actually from the first reactor start-up at the end of 1959 [sr

  10. Methodological constraints in interpreting serum paraoxonase-1 activity measurements: an example from a study in HIV-infected patients

    Directory of Open Access Journals (Sweden)

    Joven Jorge

    2010-03-01

    Full Text Available Abstract Background Paraoxonase-1 (PON1 is an antioxidant enzyme that attenuates the production of the monocyte chemoattractant protein-1 (MCP-1 in vitro. Although oxidation and inflammation are closely related processes, the association between PON1 and MCP-1 has not been completely characterised due, probably, to that the current use of synthetic substrates for PON1 measurement limits the interpretation of the data. In the present study, we explored the relationships between the circulating levels of PON1 and MCP-1 in human immunodeficiency virus-infected patients in relation to the multifunctional capabilities of PON1. Methods We measured selected variables in 227 patients and in a control group of 409 participants. Serum PON1 esterase and lactonase activities were measured as the rates of hydrolysis of paraoxon and of 5-(thiobutyl-butyrolactone, respectively. Oxidised LDL and MCP-1 concentrations were determined by enzyme-linked immunosorbent assay. High-density lipoproteins cholesterol, apolipoprotein A-I, and C-reactive protein concentrations were measured by standard automated methods. Results There were significant relationships between PON1 activity and several indices of oxidation and inflammation in control subjects and in infected patients. However, these relationships varied not only with disease status but also on the type of substrate used for PON1 measurement. Conclusion The present study is a cautionary tale highlighting that results of clinical studies on PON1 may vary depending on the methods used as well as the disease studied. Until more specific methods using physiologically-akin substrates are developed for PON1 measurement, we suggest the simultaneous employment of at least two different substrates in order to improve the reliability of the results obtained.

  11. Clinical significance of measurements of serum IL-6 levels in patients with cardiovascular and cerebrovascular diseases

    International Nuclear Information System (INIS)

    Wu Cuihua; Luo Nanping; Zhang Daojie; Wei Hong

    2004-01-01

    Objective: To explore the clinical significance of changes of serum IL-6 levels in patients with cardiovascular and cerebrovascular diseases. Methods: Serum IL-6 levels were determined with RIA in 35 patients with coronary heart disease, 20 patients with essential hypertension, 28 patients with cerebral infarction and 30 controls. Results: Serum IL-6 levels in patients with coronary heart disease and cerebral infarction were significantly higher than those in the controls (P 0.05). Conclusion: Serum IL-6 levels changes could reflect the severity of the inflammatory process and would be helpful in clinical assessment. (authors)

  12. Measurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry☆

    Science.gov (United States)

    Upreti, Rita; Homer, Natalie Z.M.; Naredo, Gregorio; Cobice, Diego F.; Hughes, Katherine A.; Stewart, Laurence H.; Walker, Brian R.; Andrew, Ruth

    2013-01-01

    A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100 μL) via liquid–liquid extraction with methyl tert-butyl ether (2 mL) following dilution with 0.1 M ammonium hydroxide (100 μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis® Express C18 (100 mm × 3 mm, 2.7 μm) column using a gradient elution with mobile phases methanol and 2 mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6 min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409 → 228 and d9-finasteride m/z 382 → 318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10 ppm). The limit of quantitation was 0.2 ng/mL, and the method was validated in the linear range 0.2–50 ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. PMID:23743242

  13. Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma

    Directory of Open Access Journals (Sweden)

    Nakamura M

    2011-08-01

    Full Text Available Naoko Aizawa, Yu Yokoyama, Naoki Chiba, Kazuko Omodaka, Masayuki Yasuda, Takaaki Otomo, Masahiko Nakamura, Nobuo Fuse, Toru NakazawaDepartment of Ophthalmology, Tohoku University Graduate School of Medicine Sendai, Miyagi, JapanBackground: Laser speckle flowgraphy (LSFG enables noninvasive quantification of the retinal circulation in glaucoma patients. In this study, we tested the intrasession reproducibility of LSFG-NAVI, a modified LSFG technique.Methods: Sixty-five eyes from 33 subjects (male (M:female (F = 17:16 with a mean age of 49.4 ± 11.2 years were examined in this study. Two parameters indicating reproducibility – the coefficient of variation (COV and the intraclass correlation coefficient (ICC – were analyzed three times on the same day that mean blur rate (MBR was measured using LSFG-NAVI. The sites analyzed were the retinal artery and vein, the optic disk, and the choroid. Following classification according to the Glaucoma Hemifield Test (GHT; SITA-Standard 30-2 program, the COV and ICC were examined in patients with (GHT+; 38 eyes, M:F = 20:18, average age 48.9 ± 12.8 years and without (GHT-; 27 eyes, M:F = 13:14, average age 50.1 ± 8.7 years abnormal glaucomatous visual fields.Results: For all subjects, the intrasession reproducibility of MBR in the optic disk (COV: 3.4 ± 2.0; ICC: 0.95 and choroid (COV: 4.7 ± 3.4; ICC: 0.98 was excellent. The reproducibility for the retinal vein (COV: 8.4 ± 5.6, ICC: 0.90 and retinal artery (COV: 10.9 ± 9.9, ICC: 0.9 was moderate. MBRs in the optic disk had good reproducibility in both the GHT+ group (COV: 3.8 ± 2.0; ICC: 0.97 and the GHT− group (COV: 2.9 ± 2.1; ICC: 0.95. Local assessment of the optic disk in normal or glaucoma patients showed that the COVs of the quadrant optic disk areas were best in the temporal area of MBR (3.4%, 4.2%, respectively.Conclusion: LSFG-NAVI showed favorable reproducibility in evaluation of retinal circulation of glaucoma patients, particularly in

  14. Measurement of serum testosterone during androgenic suppression in patients with prostate cancer: A systematic review.

    Science.gov (United States)

    Morote, J; Regis, L; Celma, A; Planas, J

    2016-10-01

    Clinical practice guidelines recommend measuring serum testosterone (ST) during androgenic suppression (AS) to assess its efficacy and define castration resistance (CR). The objectives of this systematic review were to assess the level of scientific evidence that justify checking ST levels during AS, when to perform it and for what purpose. We performed a search in PubMed with the following mesh terms: androgen suppression, testosterone, and prostate cancer. The search was narrowed to original articles published in English. We found 8 publications that analysed the clinical impact of ST concentrations during AS. In all of the series, ST was measured using chemiluminescent assays. However, only indirect methods based on liquid or gas chromatography for its extraction and subsequent quantification using mass spectrometry are recommended, especially for measuring low levels. The endpoints were specific survival and CR-free survival. Six studies were retrospective. The series were not uniform in terms of clinical stage, types of AS and ST assessment methods. In general, low ST levels (<20ng/dL or <32ng/dL) were related to longer CR-free survival. The measurements were performed every 3 or 6 months. Four studies confirmed the beneficial effect of adding bicalutamide when detecting microelevations above 50ng/dL. The level of scientific evidence justifying the measurement of ST during AS is low, and the methods employed for quantifying ST levels are inadequate. However, we consider it useful to check ST levels during AS, and there appears to be an association between low ST levels and better disease outcomes. In the event of microelevations above 50ng/dL, we recommend the administration of bicalutamide. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Nathalia Cristine; Junqueira, Jose Luiz Cinta; Panzarella, Francine Keuhi; Raitz, Ricardo [Sao Leopoldo Mandic Research Center, Dept. of Oral Radiology, College of Dentistry, Sao Paulo (Brazil); Brriviera, Mauricio [Dept. of Oral Radiology, College of Dentistry, Catholic University of Brasilia, Sao Paulo (Brazil)

    2017-03-15

    This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT (Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal (distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

  16. SU-E-I-53: Variation in Measurements of Breast Skin Thickness Obtained Using Different Imaging Modalities

    International Nuclear Information System (INIS)

    Nguyen, U; Kumaraswamy, N; Markey, M

    2014-01-01

    Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution, with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality

  17. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  18. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  19. Measurement of spesific IgG to 14 foods in the serum of 32 alleric patients

    International Nuclear Information System (INIS)

    Zou Hanbing; Xu Yiping

    2006-01-01

    To evaluate the serum specific IgG to 14 food allergens in allergic patients, the food specific IgG was measured by ELISA in 32 allergic patients as well as 22 normal subjects. Results showed that the food specific IgG increased in 32 allergic patients. The positive rates for allergic patients were: shrimp: 34.4%, peanut:21.9%, egg:18.8%, crab:15.6%, wheat:12. 5%, ling:9.4%, corn:6.3%, soja:6.3%, beef:3.1%, mushroom:3.1%, tomato:3.1%, chicken:0, pork:0, rice:0. Only low increased levels of specific IgG to egg and pork in normal subjects were found with the same positive rate of 4.5% and the specific IgG to other food were negative. The fact that the food specific IgG increased in allergic disease patients means that not only IgE but also IgG could be prodused in allergic patients and there exists some relation between the two antibodies. It suggests that the measurement of food specific IgG in patients suffering from food allergy might be useful for diagnosis, prevention and treatment for such patients. (authors)

  20. The measurement of serum fibrinogen levels in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Omran, Mohammad T.; Asadollahi, S.

    2007-01-01

    Serum fibrinogen level (SF) is thought to be one of the risk factors for coronary artery disease (CAD). The purpose of this study was to measure the SFL in patients with acute coronary syndrome (ACS). This study was performed in patients with ACS, admitted in Shahid Beheshti Hospital, Babol, Iran, from February 2005 to June 2006. Two hundred patients with ACS were divided into 4 groups: Group I - ST elevated myocardial infarction (STEMI); Group II - non-ST elevated myocardial infarction (NSTEMI), Group III - unstable angina (U/A) with ST-T change and Group IV: U/A without ST-T change. Each group includes 50 patients. Twenty-four hours after admission, the SFL was measured using chromatography methods. The data were collected and analyzed. The mean SFL per mg/dl in each group are Group I - 377.8+-28, Group II - 417.2+-26.8, Group III - 335.4+-19.8 and Group IV - 305.1+-13.8. The SFL in Group II was significantly higher in the other group (p=0.002). The SFL in Group II was higher than in Group III (p=0.02) and much higher than in Group IV (p=0.000). The SFL in Group III was more than in Group IV (p=0.018). The results show that SFL is an important marker in patients with ACS, with ST-T change. (author)

  1. Lack of utility of measuring serum bilirubin concentration in distinguishing perforation status of pediatric appendicitis.

    Science.gov (United States)

    Bonadio, William; Bruno, Santina; Attaway, David; Dharmar, Logesh; Tam, Derek; Homel, Peter

    2017-06-01

    Pediatric appendicitis is a common, potentially serious condition. Determining perforation status is crucial to planning effective management. Determine the efficacy of serum total bilirubin concentration [STBC] in distinguishing perforation status in children with appendicitis. Retrospective review of 257 cases of appendicitis who received abdominal CT scan and measurement of STBC. There were 109 with perforation vs 148 without perforation. Although elevated STBC was significantly more common in those with [36%] vs without perforation [22%], the mean difference in elevated values between groups [0.1mg/dL] was clinically insignificant. Higher degrees of hyperbilirubinemia [>2mg/dL] were rarely encountered [5%]. Predictive values for elevated STBC in distinguishing perforation outcome were imprecise [sensitivity 38.5%, specificity 78.4%, PPV 56.8%, NPV 63.4%]. ROC curve analysis of multiple clinical and other laboratory factors for predicting perforation status was unenhanced by adding the STBC variable. Specific analysis of those with perforated appendicitis and percutaneously-drained intra-abdominal abscess which was culture-positive for Escherichia coli showed an identical rate of STBC elevation compared to all with perforation. The routine measurement of STBC does not accurately distinguish perforation status in children with appendicitis, nor discern infecting organism in those with perforation and intra-abdominal abscess. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Purification and characterization of an inhibitor (soluble tumor necrosis factor receptor) for tumor necrosis factor and lymphotoxin obtained from the serum ultrafiltrates of human cancer patients

    International Nuclear Information System (INIS)

    Gatanaga, Tetsuya; Whang, Chenduen; Cappuccini, F.; Lucci, J.A. III; Jeffes, E.W.B.; Kohr, W.; Lentz, R.; Tomich, J.; Yamamoto, R.S.; Granger, G.A.

    1990-01-01

    Serum ultrafiltrates (SUF) from human patients with different types of cancer contain a blocking factor (BF) that inhibits the cytolytic activity of human tumor necrosis factor α (TNF-α) in vitro. BF is a protein with a molecular mass of 28kDa on reducing sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS/PAGE). The active material was purified to homogeneity by a combination of affinity chromatography, PAGE, and high-pressure liquid chromatography. Amino acid sequence analysis revealed that BF is derived from the membrane TNF receptor. Purified BF blocks the lytic activity of recombinant human and mouse TNF-α and recombinant human lymphotoxin activity of TNF-α and recombinant human lymphotoxin on murine L929 cells in vitro. However, BF inhibits the lytic activity of TNF-α more effectively than it does that of lymphotoxin. The BF also inhibits the necrotizing activity of recombinant human TNF-α when coinjected into established cutaneous Meth A tumors in BALB/c mice. The BF may have an important role in (i) the regulation and control of TNF-α and lymphotoxin activity in cancer patients, (ii) interaction between the tumor and the host antitumor mechanisms, and (iii) use of systemically administered TNF-α in clinical trials with human cancer patients

  3. Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

    Science.gov (United States)

    Pendse, Amruta; Jasani, Bonny; Nanavati, Ruchi; Kabra, Nandkishor

    2017-08-15

    To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. Transcutaneous bilirubin has a good correlation with total serum bilirubin after initiation of phototherapy. (r=0.918, Pbilirubin at 28-32 weeks of gestation (r = 0.97) was better correlated with total serum bilirubin than those at 32-37 weeks (r =0.88). The correlation was better for neonates 72 hours of age (r = 0.82). Transcutaneous bilirubin correlates significantly with total serum bilirubin at the patched sternal site after initiation of phototherapy in preterm neonates.

  4. Influence of exercise on serum levels of myoglobin measured by radioimmunoassay.

    Science.gov (United States)

    Sabriá, M; Ruibal, A; Rey, C; Foz, M; Domenech, F M

    1983-01-01

    To determine the influence of exercise on serum levels of myoglobin, serum levels of this protein were determined by RIA in 90 healthy men, divided as follows: (1) Basal control (no exercise) 25 cases; (2) Moderate exercise (after subject had been working for 12 h in Medicine Emergency Service) 19 cases, and (3) Intensive exercise: (a) football professional (45-min match) 10 cases; (b) football amateur (45-min match) 10 cases; (c) basketball professional (45-min match) 10 cases, and (d) basketball professional (90-min training) 16 cases. Our results led us to the following conclusions. (1) Moderate exercise, such as the usual daily work, does not modify myoglobin levels; (2) Myoglobin serum levels after exercise increase in nearly all individuals. They are higher in untrained people; (3) There seems to be a correlation between exercise intensity and increase of myoglobin serum levels, and (4) The detection of serum myoglobin by RIA may have a wide field of application for sport medicine.

  5. Influence of exercise on serum levels of myoglobin measured by radioimmunoassay

    International Nuclear Information System (INIS)

    Sabria, M.; Rey, C.; Foz, M.; Ruibal, A.; Domenech, F.M.

    1983-01-01

    To determine the influence of exercise on serum levels of myoglobin, serum levels of this protein were determined by RIA in 90 healthy men, divided as follows: (1) Basal control (no exercise) 25 cases; (2) Moderate exercise (after subject had been working for 12 h in Medicine Emergency Service) 19 cases, and (3) Intensive exercise: (a) football professional (45-min match) 10 cases; (b) football amateur (45-min match) 10 cases; (c) basketball professional (45-min match) 10 cases, and (d) basketball professional (90-min training) 16 cases. Our results led us to the following conclusions. (1) Moderate exercise, such as the usual daily work, does not modify myoglobin levels; (2) Myoglobin serum levels after exercise increase in nearly all individuals. They are higher in untrained people; (3) There seems to be a correlation between exercise intensity and increase of myoglobin serum levels, and (4) The detection of serum myoglobin by RIA may have a wide field of application for sport medicine. (orig.)

  6. Influence of exercise on serum levels of myoglobin measured by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Sabria, M; Rey, C; Foz, M; Ruibal, A; Domenech, F M

    1983-04-01

    To determine the influence of exercise on serum levels of myoglobin, serum levels of this protein were determined by RIA in 90 healthy men, divided as follows: (1) Basal control (no exercise) 25 cases; (2) Moderate exercise (after subject had been working for 12 h in Medicine Emergency Service) 19 cases, and (3) Intensive exercise: (a) football professional (45-min match) 10 cases; (b) football amateur (45-min match) 10 cases; (c) basketball professional (45-min match) 10 cases, and (d) basketball professional (90-min training) 16 cases. Our results led us to the following conclusions. (1) Moderate exercise, such as the usual daily work, does not modify myoglobin levels; (2) Myoglobin serum levels after exercise increase in nearly all individuals. They are higher in untrained people; (3) There seems to be a correlation between exercise intensity and increase of myoglobin serum levels, and (4) The detection of serum myoglobin by RIA may have a wide field of application for sport medicine.

  7. Serial measurements of serum human placental lactogen (hPL) and serial ultrasound examinations in the evaluation of fetal growth

    DEFF Research Database (Denmark)

    Sørensen, Steen; von Tabouillot, D; Schioler, V

    2000-01-01

    Serial serum hPL measurements and serial ultrasound fetometry were compared in the evaluation of fetal growth by relating these two parameters to size at birth and to clinical factors known to influence size at birth. The data were from a prospective study of 1000 consecutive pregnant women...... considered to be at risk for fetal growth retardation with retrospective analysis. Serum hPL was measured by radioimmunoassay and fetal weight estimated by ultrasound every 3 weeks during the last trimester. hPL values were expressed as multiples of the median (MoM) and linear regression analysis of the h......PL MoM values was carried out for each pregnancy to find the slope of the line (hPL-slope); at least 3 serum hPL values were required. The estimated fetal weight and weight-for-age at birth was expressed in Z-scores. The individual intrauterine growth velocity was calculated by regression analysis...

  8. Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

    Science.gov (United States)

    Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.

    2009-01-01

    Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range. PMID:19933777

  9. Agreement of serum potassium measured by blood gas and biochemistry analyzer in patients with moderate to severe hyperkalemia.

    Science.gov (United States)

    Acikgoz, Seyyid Bilal; Genc, Ahmet Bilal; Sipahi, Savas; Yildirim, Mehmet; Cinemre, Behice; Tamer, Ali; Solak, Yalcin

    2016-05-01

    Several studies investigated the agreement between central laboratory biochemistry analyzers and blood gas analyzers for potassium measurements. However, data are scarce when the potassium level is moderate to severely high. We aimed to evaluate the agreement between central laboratory biochemistry analyzers and blood gas analyzer in terms of serum potassium level measurement because differences in potassium at this level translate into very different clinical actions. This was a retrospective medical record review study in which patients who presented to the emergency department and had serum potassium levels ≥6mmol/L were included. Patients who did not have simultaneous potassium measurement by blood gas analyzer were excluded. We included all patients meeting potassium criteria irrespective of their underlying disease or comorbidities. We evaluated agreement between the measurement methods with Pearson correlation, Bland-Altman plot, and Sign test. A total of 118 blood sample pairs were included. The mean serum potassium level measured by biochemistry analyzer was 6.78±0.79mmol/L, whereas it was 6.16±0.86mmol/L by blood gas analyzer (Pbiochemistry analyzer. The mean difference between the methods was 0.62±0.43mmol/L. In patients with moderate to severe hyperkalemia, blood gas analyzer and biochemistry analyzer gives significantly different serum potassium results which may be clinically important. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  11. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  12. Measurement of serum amyloid A1 (SAA1), a major isotype of acute phase SAA.

    Science.gov (United States)

    Xu, Yuanyuan; Yamada, Toshiyuki; Satoh, Takahiko; Okuda, Yasuaki

    2006-01-01

    Serum amyloid A (SAA), a plasma precursor of reactive amyloid deposits, is a multigene product. SAA1 and SAA2, with primary structures that are 93% identical (98 of 104 amino acids), behave as acute phase proteins, as demonstrated by their increasing levels in plasma. Heretofore, it has been understood that SAA1 predominates and functions as an isotype in plasma. However, accurate measurements differentiating the two isotypes have not been reported. In this study, using monoclonal antibodies specific for SAA1, we developed an enzyme-linked immunosorbent assay (ELISA) for SAA1. The levels and ratios of SAA1 in total SAA (TSAA) were investigated in healthy subjects and patients with rheumatoid arthritis (RA). The SAA1/TSAA ratio was 74 +/- 12% and 77 +/- 12% in healthy subjects and RA patients, respectively. In RA patients, the ratios were not influenced by SAA1 genotype, which has been proposed to affect plasma SAA values. The kinetics of SAA1 in inflamed patients undergoing hemodialysis was found to be parallel with total SAA and C-reactive protein. Finally, this study confirmed that SAA1 is a major isotype of acute phase SAA and may determine total SAA values. This specific assay could be used in the evaluation of SAA behavior in several clinical conditions.

  13. Comparison of accelerator and radiometric radiocarbon measurements obtained from Late Devensian Lateglacial lake sediments from Llyn Gwernan, North Wales, UK

    International Nuclear Information System (INIS)

    Lowe, J.J.; Lowe, S.; Fowler, A.J.

    1988-01-01

    Accelerator mass spectrometry measurements of the radiocarbon activity of various chemical fractions prepared from Late Devensian Lateglacial lake sediments from the site of Llyn Gwernan, near Cader Idris. North Wales are presented and assessed. These are compared with radiocarbon measurements obtained by radiometric (decay) counting which were reported earlier from the same site and are considered in the light of pollen-stratigraphic information. The potensial advantages of accelerator radiocarbon measurements to the assessment of the chronology and correlation of Lateglacial lake sediments are evaluated

  14. IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasma or serum

    NARCIS (Netherlands)

    Burnett, RW; Covington, AK; Fogh-Andersen, N; Kulpmann, WR; Lewenstam, A; Mas, AHJ; VanKessel, AL; Zijlstra, WG

    A reference measurement procedure for substance concentration determination of total CO, in blood, plasma (the anticoagulant is usually heparin) or serum is described. The document covers the principle of the method, the materials and equipment needed and essential aspects of the procedure. The

  15. Development Of Solid Phase Radioimmunoassay Using Antibody Coupled Cellulose Particles For Measurement Of Prolactin In Human Serum

    International Nuclear Information System (INIS)

    Abdel-Ghany, I.Y.

    2013-01-01

    The objective of the present study was to prepare solid phase radioimmunoassay (RIA) reagents. Development as well as optimization and validation of RIA system using solid phase cellulose particles for the measurement of prolactin (PRL) in human serum were described. The production of polyclonal antibodies was carried out by immunizing three Balb/C mice intraperitoneal through primary injection and two booster doses. The activation of cellulose particles using 1,1-carbonyl diimidazole (CDI) and coupling of these solid phase particles with IgG fraction of mouse anti-PRL were carried out. Preparation of 125 I-PRL tracer was prepared using lactoperoxidase method then purified by gel filtration using sephadex G-100. The PRL standards were prepared using a highly purified PRL antigen with assay buffer as standard matrix. Optimization and validation of the assay were carried out. The results obtained provide a low cost, simple, sensitive, specific and accurate RIA system of prolactin based on solid phase separation. These cellulose particles retain their characteristics during storage for 6 months at 4 degree C. In conclusion, this assay could be used as a useful diagnostic tool for pituitary dysfunctions and possible reproductive disability

  16. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    Science.gov (United States)

    Atkinson, Dean B.; Pekour, Mikhail; Chand, Duli; Radney, James G.; Kolesar, Katheryn R.; Zhang, Qi; Setyan, Ari; O'Neill, Norman T.; Cappa, Christopher D.

    2018-04-01

    Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM1 and PM10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.

  17. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    Directory of Open Access Journals (Sweden)

    D. B. Atkinson

    2018-04-01

    Full Text Available Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM1 and PM10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.

  18. Electron/positron measurements obtained with the Mars Science Laboratory Radiation Assessment Detector on the surface of Mars

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, J.; Wimmer-Schweingruber, R.F.; Appel, J. [Kiel Univ. (Germany). Inst. of Experimental and Applied Physics; and others

    2016-04-01

    The Radiation Assessment Detector (RAD), on board the Mars Science Laboratory (MSL) rover Curiosity, measures the energetic charged and neutral particles and the radiation dose rate on the surface of Mars. Although charged and neutral particle spectra have been investigated in detail, the electron and positron spectra have not been investigated yet. The reason for that is that they are difficult to separate from each other and because of the technical challenges involved in extracting energy spectra from the raw data. We use GEANT4 to model the behavior of the RAD instrument for electron/positron measurements.We compare Planetocosmics predictions for different atmospheric pressures and different modulation parameters Φ with the obtained RAD electron/positron measurements.We find that the RAD electron/positron measurements agree well with the spectra predicted by Planetocosmics. Both RAD measurements and Planetocosmics simulation show a dependence of the electron/positron fluxes on both atmospheric pressure and solar modulation potential.

  19. Salivary Cortisol Can Replace Free Serum Cortisol Measurements in Patients With Septic Shock

    Science.gov (United States)

    Orlander, Philip R.

    2011-01-01

    Background: There is a renewed interest in adrenal function during severe sepsis. Most studies have used total serum cortisol levels; however, only free serum cortisol is biologically active. The aim of this study was to determine the validity of salivary cortisol levels as a surrogate for free serum cortisol levels during septic shock. Methods: Fifty-seven patients with septic shock were studied to determine the correlation between total serum cortisol and salivary cortisol to free serum cortisol levels. Thirty-eight patients were included in the salivary to free serum cortisol correlation. Salivary cortisol level was tested by enzyme immunoassay. Serum total cortisol, free cortisol, and cortisol-binding globulin (CBG) levels were determined by liquid chromatography-mass spectrometry, equilibrium analysis, and radioimmunoassay, respectively. Results: The mean ± SD age was 56.6 ± 18.5 years. Fifty-seven percent were women. APACHE (Acute Physiology and Chronic Health Evaluation) II score median was 26, Simplified Acute Physiology Score II median was 61, and Sequential Organ Failure Assessment median was 13. The correlation between salivary and free serum cortisol levels was 0.79 (95% CI, 0.63-0.89; P cortisol and total serum cortisol levels was 0.86 (95% CI, 0.78-0.92; P cortisol level was 2.27 ± 1.64 μg/dL. The mean ± SD salivary cortisol level was 2.60 ± 2.69 μg/dL. The mean ± SD total serum cortisol level was 21.56 ± 8.71 μg/dL. The mean ± SD CBG level was 23.54 ± 8.33 mg/dL. Conclusions: Salivary cortisol level can be used as a surrogate of free serum cortisol level in patients with septic shock with very good correlation. Salivary cortisol testing is noninvasive, easy to perform, and can be conducted daily. Trial registry: ClinicalTrials.gov; No.: NCT00523198; URL: www.clinicaltrials.gov PMID:21816912

  20. Comparison of biometric measurements obtained by the Verion Image-Guided System versus the auto-refracto-keratometer.

    Science.gov (United States)

    Velasco-Barona, Cecilio; Cervantes-Coste, Guadalupe; Mendoza-Schuster, Erick; Corredor-Ortega, Claudia; Casillas-Chavarín, Nadia L; Silva-Moreno, Alejandro; Garza-León, Manuel; Gonzalez-Salinas, Roberto

    2018-06-01

    To compare the biometric measurements obtained from the Verion Image-Guided System to those obtained by auto-refracto-keratometer in normal eyes. This is a prospective, observational, comparative study conducted at the Asociación para Evitar la Ceguera en México I.A.P., Mexico. Three sets of keratometry measurements were obtained using the image-guided system to assess the coefficient of variation, the within-subject standard deviation and intraclass correlation coefficient (ICC). A paired Student t test was used to assess statistical significance between the Verion and the auto-refracto-keratometer. A Pearson's correlation coefficient (r) was obtained for all measurements, and the level of agreement was verified using Bland-Altman plots. The right eyes of 73 patients were evaluated by each platform. The Verion coefficient of variation was 0.3% for the flat and steep keratometry, with the ICC being greater than 0.9 for all parameters measured. Paired t test showed statistically significant differences between groups (P = 0.0001). A good correlation was evidenced for keratometry values between platforms (r = 0.903, P = 0.0001 for K1, and r = 0.890, P = 0.0001). Bland-Altman plots showed a wide data spread for all variables. The image-guided system provided highly repeatable corneal power and keratometry measurements. However, significant differences were evidenced between the two platforms, and although values were highly correlated, they showed a wide data spread for all analysed variables; therefore, their interchangeable use for biometry assessment is not advisable.

  1. arXiv A method and tool for combining differential or inclusive measurements obtained with simultaneously constrained uncertainties

    CERN Document Server

    Kieseler, Jan

    2017-11-22

    A method is discussed that allows combining sets of differential or inclusive measurements. It is assumed that at least one measurement was obtained with simultaneously fitting a set of nuisance parameters, representing sources of systematic uncertainties. As a result of beneficial constraints from the data all such fitted parameters are correlated among each other. The best approach for a combination of these measurements would be the maximization of a combined likelihood, for which the full fit model of each measurement and the original data are required. However, only in rare cases this information is publicly available. In absence of this information most commonly used combination methods are not able to account for these correlations between uncertainties, which can lead to severe biases as shown in this article. The method discussed here provides a solution for this problem. It relies on the public result and its covariance or Hessian, only, and is validated against the combined-likelihood approach. A d...

  2. Relative level populations in S VI after beam-foil excitation, obtained from ANDC analyses of measured decay curves

    International Nuclear Information System (INIS)

    Engstroem, L.

    1983-01-01

    This paper reports the relative population of the levels 3p, 3d, 4d, 5d, 4f, 5g, 6g, 6h, 7h, 7i, 8i and 8k in Na-like sulfur, S VI, after beam-foil excitation at an energy of 3 MeV. For the first time the ANDC technique has been used to obtain the relative efficiency calibration of the detection system at discrete points in the wavelength interval 400-5000 A, from the analyses of measured decay curves. The advantages and limitations of this method are discussed. The populations obtained with this new technique are compared to previous measurements in multiply ionized atoms. The preferential population of the 3p and 3d levels observed in other Na-like ions is now accurately established. For the higher lying levels an almost constant population is observed. (Auth.)

  3. Technique for measuring picomolar amounts of bound and unbound amino acids obtained from myogenic cell cultures of skeletal muscle

    International Nuclear Information System (INIS)

    Bullaro, J.C.

    1981-01-01

    A procedure is described that compares the isotope dilution method of measuring picomolar amounts of amino acids obtained from cellular extracts with a direct method of analysis. Evidence is provided that shows that the direct method is at least as accurate as the isotope dilution method. In addition the direct method is as expedient an requires but a single isotope and fewer chromatograms for analysis. A procedure also is described for selecting the appropriate conditions for dansylation and for measuring the loss of dansyl amino acid due to decomposition

  4. First In-Core Measurement Results Obtained with the Innovative Mobile Calorimeter CALMOS inside the OSIRIS Material Testing Reactor

    International Nuclear Information System (INIS)

    Carcreff, Hubert; Salmon, Laurent; Courtaux, Cedric

    2013-06-01

    Nuclear heating rate inside an MTR has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry [1, 2]. An innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. The development of the calorimetric probe required the manufacturing and the irradiation of mock-ups in the ex-core area, where nuclear heating rate does not exceed 2 W.g -1 . The calorimeter working mode, the different measurement procedures allowed with such a new probe and main modeling and experimental results have been already presented [3, 4]. In this paper, we present the first results obtained during several measurement campaigns carried out in 2012 and 2013 inside the OSIRIS core with the final device. For the first time, this new experimental measurement system was operated in nominal in-core thermo hydraulic conditions with nominal neutron and gamma fluxes (up to 6 W.g -1 ) in several experimental locations. After a brief presentation of the displacement system specificities, first nuclear heating distributions are presented and discussed. Experimental data were also used to upgrade the Finite Element model of the calorimeter in order to match measured temperatures with calculated ones. This model allowed to estimate a Kc correction factor which takes into account small nonlinearities when the heating rate is deduced from the calibration method. A comparison is made between nuclear heating rates determined from the probe calibration and from the zero method. In addition, an evaluation of the global uncertainty associated to the measurements is detailed. Finally, a global comparison is made with available measurements obtained from previous calorimeters. (authors)

  5. Crystal Fields in Dilute Rare-Earth Metals Obtained from Magnetization Measurements on Dilute Rare-Earth Alloys

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.

    1974-01-01

    Crystal field parameters of Tb, Dy, and Er in Sc, Y, and Lu are summarized. These parameters are obtained from magnetization measurements on dilute single crystals, and successfully checked by a number of different methods. The crystal field parameters vary unpredictably with the rare-earth solute....... B40, B60, and B66 are similar in Y and Lu. Crystal field parameters for the pure metals Tb, Dy, and Er are estimated from the crystal fields in Y and Lu....

  6. Value for money: Defining and measuring 'value' in MoD's acquisition policy of obtaining best value for money

    OpenAIRE

    Weiss, A.

    2006-01-01

    Obtaining value for money is a keystone of UK Ministry of Defence (MoD) acquisition strategy embedded in its Smart Acquisition policy. This thesis examines how best to measure the relative value of competing tender submissions for major projects. There is a comprehensive discussion of a wide range of relevant definitions and over three dozen documents are scrutinised including just some sixteen published by the Government. Commercially available models, algorithms and software are examined as...

  7. Ascorbic acid interference in the measurement of serum biochemical parameters: in vivo and in vitro studies.

    Science.gov (United States)

    Martinello, Flávia; da Silva, Edson Luiz

    2006-04-01

    To investigate the negative interference of ascorbic acid in serum biochemical tests in relation to the dose of vitamin C intake and to the time of blood collection. Healthy volunteers (n = 18) consumed daily doses of vitamin C (0.25-4.0 g) for 1 week and serum parameters were assayed prior to the experiment and on the eighth day of consumption. Blood samples were collected 4, 12 and 24 h after vitamin C intake. Serum levels of ascorbic acid increased significantly after vitamin C ingestion inhibiting urate and total bilirubin tests 4 and 12 h after intake (P cholesterol tests. Addition of ascorbic acid to serum inhibited the urate test to a similar extent to that observed after vitamin C intake. However, after ingesting vitamin C, the interference for the bilirubin test was greater than that of the in vitro interference. Commonly taken doses of supplementary vitamin C interfered negatively with the serum urate test based on the Trinder method, and with bilirubin metabolism.

  8. First in-core measurement results obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS material testing reactor

    International Nuclear Information System (INIS)

    Carcreff, Hubert; Salmon, Laurent; Courtaux, Cedric

    2014-01-01

    Nuclear heating rate inside an MTR has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. An innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. Development of the calorimetric probe required manufacturing and irradiation of mock-ups in the ex-core area, where nuclear heating rate does not exceed 2 W.g -1 . The calorimeter working mode, the different measurement procedures, main modeling and ex-core experimental results have been already presented in previous papers. In this paper, we present in-core results obtained from 2011 to 2013 with the final device. For the first time, this new experimental measurement system was operated in several experimental locations, with nominal in-core thermal hydraulic conditions, nominal neutron flux and nuclear heating rate up to 6 W.g -1 (in graphite). After a brief presentation of the displacement system specificities, first nuclear heating distributions are presented and discussed. The Finite Element model of the calorimeter was upgraded in order to match calculated temperatures with measured ones. This 'validated' model allowed to estimate a Kc factor which tends to correct small nonlinearities when heating rate is calculated from the 'calibration method'. A comparison is made between nuclear heating rates determined from 'calibration' and 'zero methods'. In addition, an evaluation of the global uncertainty associated to the measurements is detailed. Finally, a comparison is made with available measurements obtained from previous calorimeters. (authors)

  9. Measurement of a MMP-2 degraded Titin fragment in serum reflects changes in muscle turnover induced by atrophy

    DEFF Research Database (Denmark)

    Sun, S; Henriksen, K; Karsdal, M A

    2014-01-01

    used to assess biological and clinical relevance. RESULTS: A technically robust ELISA measuring the Titin fragment was developed against a Titin peptide fragment identified in human urine. The fragment was shown to be produced primarily by MMP-2 cleavage of Titin. In the rat muscle DEX induced atrophy...... model, Titin-MMP2 fragment was decreased in the beginning of DEX treatment, and then significantly increased later on during DEX administration. In the human bed rest study, the Titin-MMP2 fragment was initially decreased 11.9 (±3.7) % after 1day of bed rest, and then gradually increased ending up...... at a 16.4 (±4.6) % increase at day 47. CONCLUSIONS: We developed a robust ELISA measuring a muscle derived MMP-2 generated Titin degradation fragment in rat and human serum. Importantly, the fragment can be measured in serum and that these levels are related to induction of skeletal muscle atrophy....

  10. The Significance of Serum beta2-Microglobulin Measurement in Various Renal Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Koong, Sung Soo; Oh, Ha Yong; Han, Jin Suk; Lee, Jung Sang [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-03-15

    To evaluate change of serum beta{sub 2}-microglobulin concentration (sbeta{sub 2}-MG) and the usefulness of sbeta{sub 2}-MG and sbeta{sub 2}-MG/serum creatinine concentration (sCr) ratio in various renal diseases, sbeta{sub 2}-MG and sCr were measured in 25 normal controls and 90 patients of various renal diseases (16 cases of glomerulonephritis, 12 cases of acute renal failure, 8 cases of chronic renal failure, 24 cases of nephrotic syndrome, 15 cases of tubulointerstitial diseases and 15 cases of lupus nephritis) using Phadebas beta{sub 2}-Micro Test kits. The results were as follows; 1) In normal control, the mean value of sbeta{sub 2}-MG was 1.65+-0.41 mg/l and the mean value of sbeta{sub 2}-MG/sCr ratio was 0.14+-0.05. 2) In various renal diseases, the mean value of sbeta{sub 2}-MG was 6.74+-5.47 mg/l. The mean value of sbeta{sub 2}-MG/sCr ratio was 0.24+-0.11 and significantly elevated than that of normal contro1. (P<0.05). 3) The correlation between sbeta-2-MG and sCr in glomerular and tubulointerstitial disease was log sbeta{sub 2}-MG=0.90 log sCr-0.48 and its correlation coefficient was 0.78 (P<0.05). 4) In glomerular disease, the correlation between sbeta{sub 2}-MG and sCr was log sbeta{sub 2}-MG=0.89 log sCr-0.46 (r-0.76) and in tubulointerstitial disease, it was log sbeta{sub 2}-MG=0.95 1og sCr-0.59 (r-0.87). There was no significant difference between the two groups (p<0.05). 5) Among 32 cases of glomerular and tubulointerstitial disease patients, whose sCr was within normal range, 17 cases showed elevated sbeta{sub 2}-MG. The mean values of sbeta{sub 2}-MG/sCr ratio in these patients was 0.30+-0.14 and significantly elevated than that of normal control (p<0.05). 6) In 15 cases of lupus nephritis, 12 cases showed elevated sbeta{sub 2}-MG with normal sCr and 12 cases showed elevated sbeta{sub 2}-MG/sCr ratio. With above results, It was found that the sbeta{sub 2}-MG can be used as an index of glomerular filtration rate as in the case of sCr and thats

  11. The clinical value of measurement of serum leptin, α1-acid glycoprotein and alphal-antitrypsine levels in patients with lung cancer

    International Nuclear Information System (INIS)

    Hu Xingrong; Deng Zihui; Xue Hui; Yan Guangtao

    2010-01-01

    Objective: To investigate the early diagnostic value of measurement of changes of serum leptin, α 1 -acid glycoprotein (AAG) and alphal-antitrypsine (α 1 AT)levels in patients with lung cancer. Methods: Serum leptin (with RIA)and serum AAG and α 1 AT (with ELISA) levels were determined in 89 patients with lung cancer and 60 controls. Results: The serum levels of leptin, AAG and α 1 AT in patients with lung cancer were significantly higher than those in the controls. No correlations among the investigated serum parameters were demonstrated. Conclusion: Serum leptin, AAG and α 1 AT levels are higher in patients with lung cancer. They may play inde-pendent roles in the development of lung cancer. Detection of the serum concentrations of leptin, AAG and α 1 AT is valuable for early diagnosis of lung cancer. (authors)

  12. Plasma-Serum Cholesterol Differences in Children and Use of Measurements from Different Specimens

    NARCIS (Netherlands)

    Berentzen, N.E.; Wijga, A.H.; Rossem, van L.; Jongste, de J.C.; Boshuizen, H.C.; Smit, H.A.

    2013-01-01

    Background: We aimed to assess absolute plasma-serum differences and differences in ranking of total cholesterol (TC), high-density lipoprotein cholesterol (HDLC), and TC/HDLC ratio in children. Methods: We analysed data of 412 children participating in a Dutch birth cohort. TC, HDLC, and TC/HDLC

  13. Maternal serum laeverin (aminopeptidase Q) measured in the first trimester of pregnancy does not predict preeclampsia

    DEFF Research Database (Denmark)

    Pihl, Kasper; Sørensen, Steen; Nystad, Mona

    2018-01-01

    OBJECTIVE: The aim of this study was to compare the laeverin level in maternal serum from first trimester (11-14 weeks) of pregnancy between normal pregnancies and pregnancies that later developed preeclampsia (PE). MATERIAL AND METHODS: This was a case-cohort study. The laeverin concentration wa...

  14. Determining Vaccination Frequency in Farmed Rainbow Trout Using Vibrio anguillarum O1 Specific Serum Antibody Measurements

    DEFF Research Database (Denmark)

    Holten-Andersen, Lars; Dalsgaard, Inger; Nylén, Jørgen

    2012-01-01

    Background Despite vaccination with a commercial vaccine with a documented protective effect against Vibrio anguillarum O1 disease outbreaks caused by this bacterium have been registered among rainbow trout at Danish fish farms. The present study examined specific serum antibody levels as a valid...

  15. Remote measurement of water color in coastal waters. [spectral radiance data used to obtain quantitative values for chlorophyll and turbidity

    Science.gov (United States)

    Weldon, J. W.

    1973-01-01

    An investigation was conducted to develop procedure to obtain quantitative values for chlorophyll and turbidity in coastal waters by observing the changes in spectral radiance of the backscattered spectrum. The technique under consideration consists of Examining Exotech model 20-D spectral radiometer data and determining which radiance ratios best correlated with chlorophyll and turbidity measurements as obtained from analyses of water samples and sechi visibility readings. Preliminary results indicate that there is a correlation between backscattered light and chlorophyll concentration and secchi visibility. The tests were conducted with the spectrometer mounted in a light aircraft over the Mississippi Sound at altitudes of 2.5K, 2.8K and 10K feet.

  16. The measurement and calculation of the X-ray spatial resolution obtained in the analytical electron microscope

    International Nuclear Information System (INIS)

    Michael, J.R.; Williams, D.B.

    1990-01-01

    The X-ray microanalytical spatial resolution is determined experimentally in various analytical electron microscopes by measuring the degradation of an atomically discrete composition profile across an interphase interface in a thin-foil of Ni-Cr-Fe. The experimental spatial resolutions are then compared with calculated values. The calculated spatial resolutions are obtained by the mathematical convolution of the electron probe size with an assumed beam-broadening distribution and the single-scattering model of beam broadening. The probe size is measured directly from an image of the probe in a TEM/SETEM and indirectly from dark-field signal changes resulting from scanning the probe across the edge of an MgO crystal in a dedicated STEM. This study demonstrates the applicability of the convolution technique to the calculation of the microanalytical spatial resolution obtained in the analytical electron microscope. It is demonstrated that, contrary to popular opinion, the electron probe size has a major impact on the measured spatial resolution in foils < 150 nm thick. (author)

  17. Algorithm for repairing the damaged images of grain structures obtained from the cellular automata and measurement of grain size

    Science.gov (United States)

    Ramírez-López, A.; Romero-Romo, M. A.; Muñoz-Negron, D.; López-Ramírez, S.; Escarela-Pérez, R.; Duran-Valencia, C.

    2012-10-01

    Computational models are developed to create grain structures using mathematical algorithms based on the chaos theory such as cellular automaton, geometrical models, fractals, and stochastic methods. Because of the chaotic nature of grain structures, some of the most popular routines are based on the Monte Carlo method, statistical distributions, and random walk methods, which can be easily programmed and included in nested loops. Nevertheless, grain structures are not well defined as the results of computational errors and numerical inconsistencies on mathematical methods. Due to the finite definition of numbers or the numerical restrictions during the simulation of solidification, damaged images appear on the screen. These images must be repaired to obtain a good measurement of grain geometrical properties. Some mathematical algorithms were developed to repair, measure, and characterize grain structures obtained from cellular automata in the present work. An appropriate measurement of grain size and the corrected identification of interfaces and length are very important topics in materials science because they are the representation and validation of mathematical models with real samples. As a result, the developed algorithms are tested and proved to be appropriate and efficient to eliminate the errors and characterize the grain structures.

  18. Electron/positron measurements obtained with the Mars Science Laboratory Radiation Assessment Detector on the surface of Mars

    Directory of Open Access Journals (Sweden)

    J. Köhler

    2016-01-01

    Full Text Available The Radiation Assessment Detector (RAD, on board the Mars Science Laboratory (MSL rover Curiosity, measures the energetic charged and neutral particles and the radiation dose rate on the surface of Mars. Although charged and neutral particle spectra have been investigated in detail, the electron and positron spectra have not been investigated yet. The reason for that is that they are difficult to separate from each other and because of the technical challenges involved in extracting energy spectra from the raw data. We use GEANT4 to model the behavior of the RAD instrument for electron/positron measurements. We compare Planetocosmics predictions for different atmospheric pressures and different modulation parameters Φ with the obtained RAD electron/positron measurements. We find that the RAD electron/positron measurements agree well with the spectra predicted by Planetocosmics. Both RAD measurements and Planetocosmics simulation show a dependence of the electron/positron fluxes on both atmospheric pressure and solar modulation potential.

  19. Development of unfolding method to obtain pin-wise source strength distribution from PWR spent fuel assembly measurement

    International Nuclear Information System (INIS)

    Sitompul, Yos Panagaman; Shin, Hee-Sung; Park, Se-Hwan; Oh, Jong Myeong; Seo, Hee; Kim, Ho Dong

    2013-01-01

    An unfolding method has been developed to obtain a pin-wise source strength distribution of a 14 × 14 pressurized water reactor (PWR) spent fuel assembly. Sixteen measured gamma dose rates at 16 control rod guide tubes of an assembly are unfolded to 179 pin-wise source strengths of the assembly. The method calculates and optimizes five coefficients of the quadratic fitting function for X-Y source strength distribution, iteratively. The pin-wise source strengths are obtained at the sixth iteration, with a maximum difference between two sequential iterations of about 0.2%. The relative distribution of pin-wise source strength from the unfolding is checked using a comparison with the design code (Westinghouse APA code). The result shows that the relative distribution from the unfolding and design code is consistent within a 5% difference. The absolute value of the pin-wise source strength is also checked by reproducing the dose rates at the measurement points. The result shows that the pin-wise source strengths from the unfolding reproduce the dose rates within a 2% difference. (author)

  20. Anti-DNA antibody in serum measured by radioimmunoassay (Farr technique)

    Energy Technology Data Exchange (ETDEWEB)

    Manthorpe, R; Palit, J; Bendixen, G [Rigshospitalet, Copenhagen (Denmark)

    1978-01-01

    The anti DNA antibody determination in serum is increasingly used because it supports the diagnosis of systemic lupus erythematosus (SLE) with high selectivity. The present work evaluates several of the technical variables of the Farr radioimmunoassay for anti-DNA antibody determination and describes a recommendable procedure. The most important sources of error are emphasized and the range for normal blood donors and a group of hospital patients without SLE is given.

  1. Anti-DNA antibody in serum measured by radioimmunoassay (Farr technique)

    International Nuclear Information System (INIS)

    Manthorpe, R.; Palit, J.; Bendixen, G.

    1978-01-01

    Anti-DNA antibody determination in serums is increasingly used because it supports the diagnosis of systemic lupres erythematosus (SLE) with high selectivity. The present work evaluates several of the technical variables of the Farr radioimmunoassay for anti-DNA antibody determination and describes a recommendable procedure, emphasizes the most important sources of error and gives the range of normal blood donors and a group of hospital patients without SLE. (author)

  2. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers.

    Science.gov (United States)

    Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria

    2018-04-25

    The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.

  3. Association between quantitative measures obtained using fluorescence-based methods and activity status of occlusal caries lesions in primary molars.

    Science.gov (United States)

    Novaes, Tatiane Fernandes; Reyes, Alessandra; Matos, Ronilza; Antunes-Pontes, Laura Regina; Marques, Renata Pereira de Samuel; Braga, Mariana Minatel; Diniz, Michele Baffi; Mendes, Fausto Medeiros

    2017-05-01

    Fluorescence-based methods (FBM) can add objectiveness to diagnosis strategy for caries. Few studies, however, have focused on the evaluation of caries activity. To evaluate the association between quantitative measures obtained with FBM, clinical parameters acquired from the patients, caries detection, and assessment of activity status in occlusal surfaces of primary molars. Six hundred and six teeth from 113 children (4-14 years) were evaluated. The presence of a biofilm, caries experience, and the number of active lesions were recorded. The teeth were assessed using FBM: DIAGNOdent pen (Lfpen) and Quantitative light-induced fluorescence (QLF). As reference standard, all teeth were evaluated using the ICDAS (International Caries Detection and Assessment System) associated with clinical activity assessments. Multilevel regressions compared the FBM values and evaluated the association between the FBM measures and clinical variables related to the caries activity. The measures from the FBM were higher in cavitated lesions. Only, ∆F values distinguished active and inactive lesions. The LFpen measures were higher in active lesions, at the cavitated threshold (56.95 ± 29.60). Following regression analyses, only the presence of visible biofilm on occlusal surfaces (adjusted prevalence ratio = 1.43) and ∆R values of the teeth (adjusted prevalence ratio = 1.02) were associated with caries activity. Some quantitative measures from FBM parameters are associated with caries activity evaluation, which is similar to the clinical evaluation of the presence of visible biofilm. © 2016 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Determining the saliency of feature measurements obtained from images of sedimentary organic matter for use in its classification

    Science.gov (United States)

    Weller, Andrew F.; Harris, Anthony J.; Ware, J. Andrew; Jarvis, Paul S.

    2006-11-01

    The classification of sedimentary organic matter (OM) images can be improved by determining the saliency of image analysis (IA) features measured from them. Knowing the saliency of IA feature measurements means that only the most significant discriminating features need be used in the classification process. This is an important consideration for classification techniques such as artificial neural networks (ANNs), where too many features can lead to the 'curse of dimensionality'. The classification scheme adopted in this work is a hybrid of morphologically and texturally descriptive features from previous manual classification schemes. Some of these descriptive features are assigned to IA features, along with several others built into the IA software (Halcon) to ensure that a valid cross-section is available. After an image is captured and segmented, a total of 194 features are measured for each particle. To reduce this number to a more manageable magnitude, the SPSS AnswerTree Exhaustive CHAID (χ 2 automatic interaction detector) classification tree algorithm is used to establish each measurement's saliency as a classification discriminator. In the case of continuous data as used here, the F-test is used as opposed to the published algorithm. The F-test checks various statistical hypotheses about the variance of groups of IA feature measurements obtained from the particles to be classified. The aim is to reduce the number of features required to perform the classification without reducing its accuracy. In the best-case scenario, 194 inputs are reduced to 8, with a subsequent multi-layer back-propagation ANN recognition rate of 98.65%. This paper demonstrates the ability of the algorithm to reduce noise, help overcome the curse of dimensionality, and facilitate an understanding of the saliency of IA features as discriminators for sedimentary OM classification.

  5. Increased intestinal permeability, measured by serum zonulin, is associated with metabolic risk markers in overweight pregnant women.

    Science.gov (United States)

    Mokkala, Kati; Pellonperä, Outi; Röytiö, Henna; Pussinen, Pirkko; Rönnemaa, Tapani; Laitinen, Kirsi

    2017-04-01

    Increased intestinal permeability with subsequent metabolic endotoxemia, i.e., elevated circulating levels of bacterial lipopolysaccharide, LPS, has been introduced as a novel initiator of obesity related metabolic disturbances in non-pregnant individuals. The objective was to investigate the extent to which intestinal permeability, measured by serum zonulin concentration, is related to metabolic endotoxemia and metabolic risk markers in overweight pregnant women. This was a cross-sectional study including 100 pregnant overweight women in early pregnancy. Serum zonulin was analyzed using ELISA, and markers for metabolic endotoxemia (LPS), inflammation (high-sensitive C-reactive protein and glycoprotein acetylation GlyA), glucose metabolism (fasting glucose and insulin), and lipid metabolism were measured. Higher serum zonulin concentration associated positively with LPS (P=0.02), inflammatory markers (Pzonulin quartiles). All the observed associations were confirmed (Pzonulin concentration, i.e., increased intestinal permeability, contributes to metabolic endotoxemia, systemic inflammation, and insulin resistance in overweight pregnant women. By reinforcing intestinal barrier, it may be possible to manipulate maternal metabolism during pregnancy with subsequent health benefits. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Assumed non-persistent environmental chemicals in human adipose tissue; matrix stability and correlation with levels measured in urine and serum.

    Science.gov (United States)

    Artacho-Cordón, F; Arrebola, J P; Nielsen, O; Hernández, P; Skakkebaek, N E; Fernández, M F; Andersson, A M; Olea, N; Frederiksen, H

    2017-07-01

    The aim of this study was to (1) optimize a method for the measurement of parabens and phenols in adipose tissue, (2) evaluate the stability of chemical residues in adipose tissue samples, and (3) study correlations of these compounds in urine, serum, and adipose tissue. Samples were obtained from adults undergoing trauma surgery. Nine phenols and seven parabens were determined by isotope diluted TurboFlow-LC-MS/MS. The analytical method showed good accuracy and precision. Limits of detection (LOD) for parabens and phenols ranged from 0.05 to 1.83ng/g tissue. Good recovery rates were found, even when biological samples remained defrosted up to 24h. Benzophenone-3 (BP-3; range of values: 70% of adipose tissue samples, while bisphenol-A (BPA; 40% of adipose tissue samples. In general, levels were similar between adipose tissue and serum, while a correlation between adipose tissue and urine was only found for BP-3. In conclusion, adipose tissue samples in this study were found to contain environmental chemicals considered to be non-persistent, whose levels were weakly or not at all correlated with the urine burden. Therefore, adipose tissue may potentially provide additional information to that obtained from other biological matrices. Further investigations are warranted to explore whether adipose tissue might be a suitable matrix for assessment of the consequences for human health of mid/long-term exposure to these chemicals. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Measurement of alpha-fetoprotein in maternal serum: three commercial radioimmunoassay kits and two non-commercial radioimmunoassays compared

    International Nuclear Information System (INIS)

    Forest, J.C.; Verreault, F.; Pouliot, M.

    1982-01-01

    We evaluated three commercial radioimmunoassay kits (Amersham, Dainabot, Clinical Assays) and two non-commercial methods for determining alpha-fetoprotein in maternal serum during pregnancy. All five procedures were found to be acceptable with respect to practicability, sensitivity, linearity, and precision. Similar results were obtained with Dainabot, Clinical Assays, and the two non-commercial methods, but the Amersham method revealed a proportional error, results being about 20% lower than those by the other methods. Use of the international unit system is suggested for reporting results for AFP, to facilitate comparison between methods and laboratories

  8. Clinical significance of measurement of changes in serum NO/NOS ratio and plasma ET content after treatment in patients with acute myocardial infarction (AMI)

    International Nuclear Information System (INIS)

    Dong Zhaoshu; Liu Xugui

    2005-01-01

    Objective: To study the clinical significance of changes of plasma ET and serum NO/NOS ratio in patients with AMI after treatment. Methods: Serum NO/NOS ratio (with EIA) and plasma ET (with RIA) contents were measured in 30 patients with acute myocardial infarction both before and after treatment as well as in 35 controls. Results: Serum levels of NO were significantly lower (P 0.05), but plasma ET levels remained significantly higher (P<0.05). Conclusion: Changes of serum NO/NOS ratio and plasma ET contents after treatment might be of prognostic importance in patients with acute myocardial infarction. (authors)

  9. Clinical significance of measurement of changes of serum IGF-II, NO levels after treatment in pediatric patients with bronchial pneumonia

    International Nuclear Information System (INIS)

    Zhao Huajiang

    2005-01-01

    Objective: To study the clinical significance of changes of serum IGF-II and NO levels after treatment in pediatric patients with bronchial pneumonia. Methods: Serum IGF-II (with RIA) and NO (with Biochemical method) levels were measured in 38 pediatric patients with bronchial pneumonia both before and after treatment as well as in 35 controls. Results: Before treatment, in the patients the serum IGF-II, and NO levels were significantly higher than those in controls (P 0.05). Conclusion: Serum IGF-II and NO levels changes could reflect the disease status of the patients as well as the progress of diseases. (authors)

  10. Effects of cysteamine on pituitary, MTTW15 tumor, and serum prolactin levels measured by rat lymphoma cell bioassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Parsons, J.A.; Peterson, E.K.; Hartfel, M.A.

    1984-01-01

    Cysteamine (CSH), a sulfhydryl compound, reduces both serum and anterior pituitary (AP) PRL measured by RIA. We have used the Nb2 lymphoma cell bioassay (BIO) for PRL to evaluate possible CSH-related changes in PRL levels in sera and tissues of male and MtTW15 mammosomatotropic tumor-bearing female rats. Experimental animals received a single sc injection of CSH (300 mg/kg), and samples were collected 0.5-24 h later. Since CSH and serum from CSH rats were toxic in BIO, samples were dialyzed before assay. All samples were evaluated for PRL and GH by RIA as well. A significant decrease (P less than 0.05) in BIO serum PRL was evident in male rats 0.5 h after CSH; levels remained low for 24 h. Serum PRL by RIA was significantly depressed at 4 h but not at 0.5 h or 24 h. PRL in AP extracts was decreased (60-90%) at all times by BIO and RIA. Significant decreases of BIO- and RIA-detectable PRL were recorded in serum and tissues (AP and tumors) at 4 h in tumor rats. Sequentially bled (0.5-4 h) CSH-treated tumor-bearing rats showed 50% and 80% reductions in serum PRL at 1 and 4 h by both BIO and RIA. CSH had no effect on GH levels in sera and tissues of any animal studied at any time interval. Our results substantiate earlier reports on CSH-induced decreases in RIA-detectable PRL. They show that such changes cannot be attributed to assay effects alone, as significant decreases in circulating and stored PRL (both AP and tumor) were evident by BIO. Results with tissue extracts were the most dramatic. They suggest an action of CSH or a metabolic intermediate with stored PRL which reduces both extractable PRL and hormone release. Such an effect of CSH on PRL extraction has been suggested by others. Whatever the mechanism, it appears to be relatively specific, since GH cells were not affected

  11. Measurement of a MMP-2 degraded Titin fragment in serum reflects changes in muscle turnover induced by atrophy.

    Science.gov (United States)

    Sun, S; Henriksen, K; Karsdal, M A; Armbrecht, G; Belavý, D L; Felsenberg, D; Rittweger, J; Wang, Y; Zheng, Q; Nedergaard, A F

    2014-10-01

    In this study we sought to determine whether a Titin peptide fragment can serve as a clinical biomarker for changes in muscle mass. Mass spectrometry was used to identify Titin fragment in urine. An antibody against this Titin sequence was raised and used to develop a competitive ELISA assay for measurement in serum. Rat tissue extractions in the presence or absence of a series of proteases of interest were used to identify its enzymatic origin. A rat model of dexamethasone (DEX) induced muscle atrophy and a human 56-day bed rest study with and without vibration therapy were used to assess biological and clinical relevance. A technically robust ELISA measuring the Titin fragment was developed against a Titin peptide fragment identified in human urine. The fragment was shown to be produced primarily by MMP-2 cleavage of Titin. In the rat muscle DEX induced atrophy model, Titin-MMP2 fragment was decreased in the beginning of DEX treatment, and then significantly increased later on during DEX administration. In the human bed rest study, the Titin-MMP2 fragment was initially decreased 11.9 (±3.7) % after 1day of bed rest, and then gradually increased ending up at a 16.4 (±4.6) % increase at day 47. We developed a robust ELISA measuring a muscle derived MMP-2 generated Titin degradation fragment in rat and human serum. Importantly, the fragment can be measured in serum and that these levels are related to induction of skeletal muscle atrophy. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Measurement of human serum parathyroid hormone in disorders of calcium metabolism and during administration of certain gut hormones

    International Nuclear Information System (INIS)

    Coetzee, J.; Klaff, L.J.; Epstein, S.

    1980-01-01

    A sensitive radio-immunoassay for parathyroid hormone (PTH) using the commercially available antisera AS 211/32 and AS 211/41 has been established. The lower limit of sensitivity of the assay is 0,25 ng/ml. Seventy-nine per cent of normal subjects have PTH levels in the measurable range, with a mean of 0,49 ng/ml (SD more or less 0,26 ng/ml). Only 1 of 9 patients with proven primary hyperparathyroidism had a normal serum PTH value. The mean serum PTH value in this group was 3,0 more or less 0,26 ng/ml, which differed significantly from that in the normal group (P<0,001). The serum PTH level of 33 patients on chronic haemodialysis was uniformly raised, while in 8 patients with hypoparathyroidism PTH levels were undetectable. Patients with malignant disease presented a mixed picture, with raised, normal or undetectable PTH levels. We investigated a possible relationship between the gut hormones, gastrin, secretin and cholecystokininpancreozymin (CCK-PZ) and PTH secretion in human volunteers. No effect was found, although the investigations were conducted over relatively short time periods

  13. Clinical significance of the measurements of serum free thyroxine and free triiodothyronine concentrations

    International Nuclear Information System (INIS)

    Kubota, Ken; Sasaki, Norio; Takaku, Fumimaro; Uchimura, Hidemasa

    1988-01-01

    A commercially available ''DPC'' radioimmunoassay kit was used to study the serum concentrations of free triiodothyronine (FT3) and free thyroxine (FT4) in a series of 189 patients with various thyroid diseases and 120 healthy controls. The basal serum concentrations of FT3 and FT4 in normal controls ranged from 0.98 to 2.04 ng/dl and from 1.43 to 3.66 pg/ml, respectively. All untreated patients with Graves' disease had abnormally high FT3 and FT4 values, indicating the discrimination between hyperthyroid and normal subjects. A decreased ratio of FT4 to FT3 was observed in patients managed with antithyroid drugs. In diagnosing hypothyroidism, ''DPC'' FT4 kits were more sensitive than ''DPC'' TT4 and ''Amerlex'' FT4 kits. In the case of non-thyroid diseases, FT4 and FT3 values, as well as total T4 and total T3, were normal or decreased, with the exception of occasionally unknown high values. The interference of thyroxine binding globulin abnormablity was successfully eliminated by using new versions of ''DPC'' kits. (Namekawa, K.)

  14. Iron status of pregnant Filipino women as measured by serum ferritin.

    Science.gov (United States)

    Perlas, L A; Kuizon, M D; Tajaon, R T; Desnacido, J A

    1992-12-01

    Iron status of pregnant women at different stages of pregnancy was evaluated by comparing values for hemoglobin (Hb), red cell indices, serum iron (SI), transferrin saturation (TS) and serum ferritin (SF) values with those of a group of non-pregnant women of comparable age and socio-economic status. Mean SF values on the second and third trimesters (9.3 +/- 2.60 ng/ml and 7.1 +/- 2.19 ng/ml) were significantly lower compared to that in the first trimester (22.6 +/- 2.20 ng/ml). These levels were also lower than that found in the non-pregnant controls. The trend was the same for TS. Hemoglobin levels of the pregnant subjects were significantly lower than those of the non-pregnant women. Prevalence of iron deficiency based on SF < 12.0 ng/ml and TS < 16.0% was highest at term and lowest during the first trimester indicating a decrease in iron stores as pregnancy progressed. Sensitivity for each of the iron parameters was computed, and it was found that for the diagnosis of iron deficiency in pregnant women, SF has a greater sensitivity than TS, SI, MCV and MCH.

  15. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  16. Zearalenone Altered the Serum Hormones, Morphologic and Apoptotic Measurements of Genital Organs in Post-weaning Gilts

    Directory of Open Access Journals (Sweden)

    X. X. Chen

    2015-02-01

    Full Text Available The present study was aimed at investigating the adverse effects of dietary zearalenone (ZEA (1.1 to 3.2 mg/kg diet on serum hormones, morphologic and apoptotic measurements of genital organs in post-weaning gilts. A total of twenty gilts (Landrace×Yorkshire×Duroc weaned at 21 d with an average body weight of 10.36±1.21 kg were used in the study. Gilts were fed a basal diet with an addition of 0, 1.1, 2.0, or 3.2 mg/kg purified ZEA for 18 d ad libitum. Results showed that 3.2 mg/kg ZEA challenged gilts decreased (p<0.05 the serum levels of luteinizing hormone, however, serum levels of prolactin in gilts fed the diet containing 2.0 mg/kg ZEA or more were increased (p<0.05 compared to those in the control. Linear effects on all tested serum hormones except progesterone were observed as dietary ZEA levels increased (p<0.05. Gilts fed ZEA-contaminated diet showed increase (p<0.05 in genital organs size, hyperplasia of submucosal smooth muscles in the corpus uteri in a dose-dependent manner. However, the decreased numbers of follicles in the cortex and apoptotic cells in the ovarian were observed in gilts treated with ZEA in a dose-dependent manner. Degeneration and structural abnormalities of genital organs tissues were also observed in the gilts fed diet containing 1.1 mg/kg ZEA or more. Results suggested that dietary ZEA at 1.1 to 3.2 mg/kg can induce endocrine disturbance and damage genital organs in post-weaning gilts.

  17. Protein electrophoresis - serum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003540.htm Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  18. Bioavailability of Oral Hydrocortisone Corrected for Binding Proteins and Measured by LC-MS/MS Using Serum Cortisol and Salivary Cortisone.

    Science.gov (United States)

    Johnson, T N; Whitaker, M J; Keevil, B; Ross, R J

    2018-01-01

    The assessment absolute bioavailability of oral hydrocortisone is complicated by its saturable binding to cortisol binding globulin (CBG). Previous assessment of bioavailability used a cortisol radioimmunoassay which has cross reactivity with other steroids. Salivary cortisone is a measure of free cortisol and LC-MS/MS is the gold standard method for measuring steroids. We here report the absolute bioavailability of hydrocortisone calculated using serum cortisol and salivary cortisone measured by LC-MS/MS. 14 healthy male dexamethasone suppressed volunteers were administered 20 mg hydrocortisone either intravenously or orally by tablet. Samples of serum and saliva were taken and measured for cortisol and cortisone by LC-MS/MS. Serum cortisol was corrected for saturable binding using published data and pharmacokinetic parameters derived using the program WinNonlin. The mean (95% CI) bioavailability of oral hydrocortisone calculated from serum cortisol, unbound serum cortisol and salivary cortisone was 1.00 (0.89-1.14); 0.88 (0.75-1.05); and 0.93 (0.83-1.05), respectively. The data confirm that, after oral administration, hydrocortisone is completely absorbed. The data derived from serum cortisol corrected for protein binding, and that from salivary cortisone, are similar supporting the concept that salivary cortisone reflects serum free cortisol levels and that salivary cortisone can be used as a non-invasive method for measuring the pharmacokinetics of hydrocortisone.

  19. Spatial Variability of Soil Physical Properties Obtained with Laboratory Methods and Their Relation to Field Electrical Resistivity Measurements

    Science.gov (United States)

    Dathe, A.; Nemes, A.; Bloem, E.; Patterson, M.; Gimenez, D.; Angyal, A.; Koestel, J. K.; Jarvis, N.

    2017-12-01

    Soil spatial heterogeneity plays a critical role for describing water and solute transport processes in the unsaturated zone. Although we have a sound understanding of the physical properties underlying this heterogeneity (like macropores causing preferential water flow), their quantification in a spatial context is still a challenge. To improve existing knowledge and modelling approaches we established a field experiment on an agriculturally used silty clay loam (Stagnosol) in SE Norway. Centimeter to decimeter scale heterogeneities were investigated in the field using electrical resistivity tomography (ERT) in a quasi-3D and a real 3D approach. More than 100 undisturbed soil samples were taken in the 2x1x1 m3plot investigated with 3D ERT to determine soil water retention, saturated and unsaturated hydraulic conductivities and bulk density in the laboratory. A subset of these samples was scanned at the computer tomography (CT) facility at the Swedish University of Agricultural Sciences in Uppsala, Sweden, with special emphasis on characterizing macroporosity. Results show that the ERT measurements captured the spatial distribution of bulk densities and reflected soil water contents. However, ERT could not resolve the large variation observed in saturated hydraulic conductivities from the soil samples. Saturated hydraulic conductivity was clearly related to the macroporosity visible in the CT scans obtained from the respective soil cores. Hydraulic conductivities close to saturation mainly changed with depths in the soil profile and therefore with bulk density. In conclusion, to quantify the spatial heterogeneity of saturated hydraulic conductivities scanning methods with a resolution smaller than the size of macropores have to be used. This is feasible only when the information obtained from for example CT scans of soil cores would be upscaled in a meaningful way.

  20. Application of Measurements of Serum CA15-3 and B-AKP in Diagnosis of Bone Metastasis in Patients with Post-operative Mammary Cancer

    International Nuclear Information System (INIS)

    Liu Yan; Zhang Xia; Yuan Shiqiang

    2010-01-01

    To evaluate the diagnosis value of serum CA15-3 and B-AKP measurements in diagnosis of bone metastasis images in patients with post-operative mammary cancer, retrospective study on the bone scan images and serum CA15-3 and bone alkaline phosphatase (B-AKP) levels were performed in 92 patients with confirmed post-operative mammary gland cancer. The results showed that the serum levels of CA15-3 and B-AKP were increased step by step significantly along with the advancement of bone metastatic grading from M0 to M3 (P<0.01). The serum levels of CA15-3 and B-AKP were positively correlated with the number of bone metastasis. The positive rate of bone metastasis was 63.2% with serum CA15-3 more than 25U/mL; and the negative predictive value of bone metastasis was 94.5% with serum CA15-3 less than 25U/mL. The positive rate of bone metastasis was 59.6% with serum B-AKP levels more than 20U/L; and the negative predictive value of bone metastasis was 73.5% with serum B-AKP levels less than 20U/L. The negative predictive value of bone metastasis was 100% with serum CA15-3 less than 25U/mL and serum B-AKP levels less than 20U/L. The combined measurement of the serum CA15-3 and B-AKP levels would play an important role in diagnosis of bone scan images in patients with post-operative mammary cancer. (authors)

  1. Tc-99m-Human Serum Albumin Transit Time as a Measure of Arm Breast Cancer-Related Lymphedema

    DEFF Research Database (Denmark)

    Toyserkani, Navid M; Hvidsten, Svend; Tabatabaeifar, Siavosh

    2017-01-01

    34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent bilateral lymphoscintigraphy using intradermal injection in both hands of technetium-99m-labeled human serum albumin and sequential 5 min imaging for 5 hours. The mean transit time (MTT) in the arms was calculated...... based on time activity curves generated from injection site and arm regions. Visual lymphedema scoring was performed based on dermal backflow and lymph node presence. Excess arm volume was calculated from circumference measurements. RESULTS: The MTT (mean ± SD) was significantly longer in the lymphedema...

  2. Serum Leptin Measured in Early Pregnancy Is Higher in Women With Preeclampsia Compared With Normotensive Pregnant Women

    DEFF Research Database (Denmark)

    Taylor, Brandie; Ness, Roberta B; Olsen, Jørn

    2015-01-01

    Leptin, an adipocyte-derived hormone, plays an important role in reproduction and angiogenesis. Studies examining leptin in preeclampsia are inconsistent, possibly because of small sample sizes and variability in sampling and outcome. We conducted a nested case-control study to examine associations...... between serum leptin (measured: 9-26 weeks gestation) and preeclampsia among 430 primiparous preeclamptic women and 316 primiparous normotensive controls from the Danish National Birth Cohort. Median (interquartile range) leptin concentrations were calculated. Associations between leptin and preeclampsia...... (blood pressure ≥140/90 mm Hg), term preeclampsia (preeclampsia and delivery ≥37 weeks gestation), or preterm preeclampsia (preeclampsia and delivery

  3. Comparison of high-pressure liquid chromatography (HPLC) and Griess reagent-spectroscopic methods for the measurement of nitrate in serum from healthy individuals in the Nordic countries.

    Science.gov (United States)

    Larsen, Tine Lise; Nilsen, Valentina; Andersen, Dag Olav; Francis, George; Rustad, Pål; Mansoor, Mohammad Azam

    2008-12-01

    Bioavailability of NO can be estimated by measuring the concentration of nitrate (NO(3)) in serum. However, the methods used for the measurement NO(3) in plasma or serum show a great degree of variation. Therefore, we compared two analytical methods for the measurement of NO(3) in serum. The concentration of NO(3) in 600 serum samples collected from healthy individuals was determined by the HPLC and by the Griess reagent-spectroscopic method. The concentration of NO(3) in the samples was 29.4+/-16.1 micromol/L and 26.2+/-14.0 micromol/L (mean+/-SD) measured by HPLC and Griess reagent-spectroscopic method respectively (pHPLC method.

  4. Alaska Steller sea lion pups blood serum chemistry and hematology values measured from 1998-06-01 to 2011-07-15 (NCEI Accession 0137994)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data were used for an analysis of Steller sea lion pup health and condition by Lander et al. (2013). Serum chemistry and hematological values were measured by...

  5. Measures of anticholinergic drug exposure, serum anticholinergic activity, and all-cause postdischarge mortality in older hospitalized patients with hip fractures

    NARCIS (Netherlands)

    Mangoni, Arduino A.; van Munster, Barbara C.; Woodman, Richard J.; de Rooij, Sophia E.

    Objectives: To assess possible associations between anticholinergic drug exposure and serum anticholinergic activity (SAA) and their capacities to predict all-cause mortality in older hospitalized patients. Setting: Academic medical center. Participants and Measurements: Data on clinical

  6. Longitudinal measures of perfluoroalkyl substances (PFAS) in serum of Gullah African Americans in South Carolina: 2003-2013.

    Science.gov (United States)

    Gribble, Matthew O; Bartell, Scott M; Kannan, Kurunthachalam; Wu, Qian; Fair, Patricia A; Kamen, Diane L

    2015-11-01

    Charleston Harbor has elevated concentrations of PFAS in dolphins, but local human exposure data are limited. We sought to describe PFAS serum concentrations' temporal trends among Gullah African American residents of coastal South Carolina. Longitudinal measures of PFAS in blood serum from a Gullah clinical sample, without lupus, were examined using spaghetti plots and visit-to-visit change scores (e.g., differences in concentrations between visits) among the 68 participants with repeated measures available. We also modeled population-level trends among the 71 participants with any data using proportionate percentile models, accounting for clustering through robust standard errors. In a post-hoc analysis we examined heterogeneity of temporal trends by age through mixed-effects models for the log-transformed PFAS compounds. Population concentrations of PFOS dropped approximately 9 (95% CI: 8, 10) percent each year over 2003-2013. This was concordant with individual PFOS trajectories (median PFOS change score -21.7 ng/g wet weight, interquartile range of PFOS change scores: -32.8, -14.9) and reports for other populations over this time period. Several other compounds including PFOA, PFHxS, and PFuNDA also showed a population-level decrease. However, examination of individual trajectories suggested substantial heterogeneity. Post-hoc analyses indicated that PFAS trajectories were heterogeneous by age. Many PFAS compounds are decreasing in a sample of Gullah African Americans from coastal South Carolina. There may be age differences in the elimination kinetics of PFASs. The possible role of age as a modifier of PFAS serum trends merits further research. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Longitudinal measures of perfluoroalkyl substances (PFAS) in serum of Gullah African Americans in South Carolina: 2003–2013

    Science.gov (United States)

    Gribble, Matthew O.; Bartell, Scott M.; Kannan, Kurunthachalam; Wu, Qian; Fair, Patricia A.; Kamen, Diane L.

    2015-01-01

    Background Charleston Harbor has elevated concentrations of PFAS in dolphins, but local human exposure data are limited. Objectives We sought to describe PFAS serum concentrations’ temporal trends among Gullah African American residents of coastal South Carolina. Methods Longitudinal measures of PFAS in blood serum from a Gullah clinical sample, without lupus, were examined using spaghetti plots and visit-to-visit change scores (e.g., differences in concentrations between visits) among the 68 participants with repeated measures available. We also modeled population-level trends among the 71 participants with any data using proportionate percentile models, accounting for clustering through robust standard errors. In a post-hoc analysis we examined heterogeneity of temporal trends by age through mixed-effects models for the log-transformed PFAS compounds. Results Population concentrations of PFOS dropped approximately 9 (95% CI: 8, 10) percent each year over 2003–2013. This was concordant with individual PFOS trajectories (median PFOS change score −21.7 ng/g wet weight, interquartile range of PFOS change scores: −32.8, −14.9) and reports for other populations over this time period. Several other compounds including PFOA, PFHxS, and PFuNDA also showed a population-level decrease. However, examination of individual trajectories suggested substantial heterogeneity. Post-hoc analyses indicated that PFAS trajectories were heterogeneous by age. Conclusions Many PFAS compounds are decreasing in a sample of Gullah African Americans from coastal South Carolina. There may be age differences in the elimination kinetics of PFASs. The possible role of age as a modifier of PFAS serum trends merits further research. PMID:25819541

  8. The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.

    Science.gov (United States)

    Wang, Linchuan; Chen, Wei; Yu, Yan

    2017-01-01

    To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method. © 2016 Wiley Periodicals, Inc.

  9. Clinical significance of measurement of changes of serum IL-2, TNF-α and IFN-γ levels after treatment in patients with psoriasis

    International Nuclear Information System (INIS)

    Mou Xudong; Ren Hong; Xie Chuntao

    2010-01-01

    Objective: To study the significance of changes of serum IL-2, TNF-α and IFN-γ levels after treatment in patients with psoriasis. Methods: Serum levels of IL-2, TNF-α (with RIA) and IFN-γ (with ELISA) were measured both before and after treatment in 37 patients with psoriasis and 35 controls. Results: Before treatment, the serum IL-2 levels in patients were significantly lower than those in controls (P<0.01), while the serum TNF-α and IFN-γ levels were significantly higher (P<0.01). After treatment for 3 months, the levels though markedly corrected, were still significantly different from those in controls (P<0.05). Conclusion: The levels of serum IL-2, TNF-α and IFN-γ increased significantly in patients with psoriasis especially in those advanced cases. (authors)

  10. Clinical significance of measurement of changes of serum TNF-α and EGF levels after chemotherapy in patients with malignant hydatidiform mole

    International Nuclear Information System (INIS)

    Chen Xiaochao; Zhou Dongxia; Zhang Liming

    2008-01-01

    Objective: To study the clinical significance of changes of serum TNF-α and EGF levels after chemotherapy in patients with malignant hydatidiform mole. Methods: Serum TNF-α, EGF levels (with RIA) were measured both before and after chemotherapy in 32 patients with malignant hydatidiform mole as well as in 35 controls. Results: Before chemotherapy, serum TNF- α and EGF levels were significantly higher in the patients than those in controls (P<0.01). Six months after chemotherapy, serum TNF-α and EGF levels, though dropped markedly, remained significantly higher than those in controls (P<0.05). Conclusion: Development of malignant hydatidiform mole in patients was closely related to the serum TNF-α and EGF levels. (authors)

  11. Clinical significance of measurement of changes serum SE-CAD, CEA and CA19-9 contents after operation in patients with gastric cancer

    International Nuclear Information System (INIS)

    Jin Wentao; Jin Zeqiu; Jiang Hui

    2007-01-01

    Objective: To explore the clinical significance of changes of serum SE-CAD, CEA and CA19-9 levels in patients with gastric cancer after operation. Methods: Serum levels of soluble E-Cadherin were measured with ELISA and serum CEA, CA19 -9 levels measared with RIA in 32 patients with gastric cancer both before and 6 months after operation as well as in 30 controls. Results: Serum SE-CAD, CEA and CA19-9 levels were significantly higher in the patients than those in the controls before operation (P 0.05). Conclusion: Changes of serum SE-CAD, CEA and CA19-9 levels after operation might be prognostic importance in patients with gastric cancer. (authors)

  12. Whole Blood Reveals More Metabolic Detail of the Human Metabolome than Serum as Measured by 1H-NMR Spectroscopy: Implications for Sepsis Metabolomics

    Science.gov (United States)

    Stringer, Kathleen A.; Younger, John G.; McHugh, Cora; Yeomans, Larisa; Finkel, Michael A.; Puskarich, Michael A.; Jones, Alan E.; Trexel, Julie; Karnovsky, Alla

    2015-01-01

    Serum is a common sample of convenience for metabolomics studies. Its processing time can be lengthy and may result in the loss of metabolites including those of red blood cells (RBC). Unlike serum, whole blood (WB) is quickly processed, minimizing the influence of variable hemolysis while including RBC metabolites. To determine differences between serum and WB metabolomes, both sample types, collected from healthy volunteers, were assayed by 1H-NMR spectroscopy. A total of 34 and 50 aqueous metabolites were quantified from serum and WB, respectively. Free hemoglobin (Hgb) levels in serum were measured and the correlation between Hgb and metabolite concentrations was determined. All metabolites detected in serum were at higher concentrations in WB with the exception of acetoacetate and propylene glycol. The 18 unique metabolites of WB included adenosine, AMP, ADP and ATP, which are associated with RBC metabolism. The use of serum results in the underrepresentation of a number of metabolic pathways including branched chain amino acid degradation and glycolysis and gluconeogenesis. The range of free Hgb in serum was 0.03-0.01 g/dL and 8 metabolites were associated (p ≤ 0.05) with free Hgb. The range of free Hgb in serum samples from 18 sepsis patients was 0.02-0.46 g/dL. WB and serum have unique aqueous metabolite profiles but the use of serum may introduce potential pathway bias. Use of WB for metabolomics may be particularly important for studies in diseases like sepsis in which RBC metabolism is altered and mechanical and sepsis-induced hemolysis contributes to variance in the metabolome. PMID:26009817

  13. Measurement for serum thyroxine-binding globulin (TBG) and its clinical assessment in diagnosis of thyroid states

    International Nuclear Information System (INIS)

    Imamura, Rikiyo; Yoshimasa, Yasunao; Hamada, Satoshi

    1979-01-01

    Serum levels of thyroxine (T 4 )-binding globulin (TBG) were determined by a radioimmunoassay using cellulose-linked antibody to TBG. Values obtained in healthy young adults averaged 1.62 +- 0.25 (SD) mg/100 ml, and no significant difference was detected between males and females. The TBG levels remained within the normal limit in hyperthyroidism while they were significantly increased in hypothyroidism. Interestingly enough, TBG levels were significantly elevated in chronic thyroidities with no overt hypothyroidism. In normal pregnancy, TBG was increased slightly in the first trimester, and markedly in the second and third trimesters. In one case of congenital TBG deficiency, no immunoreactive TBG was detected. It was demonstrated, further, that an inverse relationship (r = -0.7593) existed between the TBG level and serum triiodothyronine uptake index, and that a direct relation (r = +0.6557) was present between the TBG level and T 4 in sera from normal subjects and pregnancy. Ratios of T 4 /TBG were markedly increased in hyperthyroidism, and decreased in hypothyroidism, showing no overlap with the normal subjects, whereas they were below the normal limit in half the cases in the second and third trimesters of pregnancy. The radioimmunoassay for TBG was useful in evaluating hypothyroid states, because it could differentiate the increase in T 4 associated with elevated TBG from hyperthyroidism. (author)

  14. Solid Phase Radioimmunoassay for Measuring Serum Triiodothyronine and Thyroxine using Different Preparations of Their Labeled Hormones

    International Nuclear Information System (INIS)

    El Kolaly, M.T; Mehany, N.L; Ayyoub, S.M.; Hassan, S.E.M.

    2005-01-01

    The goal of the present work was oriented to prepare stable polystyrene coated tubes for direct radioimmunoassay (RIA) of triiodothyronine (T 3 ) and thyroxine (T 4 ) in human serum or plasma. Coating process was performed using sheep polyclonal antisera specific for each of T 3 and T 4 . The stability study showed that these tubes could be stored for up to one year at 4 degree without any appreciable reduction in their binding. The preparations of 25 I-T 3 and 125 I-T 4 were carried out by two different methods [chloramine-T(Ch-T) and iodogen] . It was found that Ch-T method gave approximately the same results as iodogen method. Twenty five samples of different thyroid status were assayed for T 3 and T 4 using the present systems and with commerically available kits (coated tubes, DPC). The statistical analysis revealed good correlations between the results from the present systems using T 3 and T 4 tracers prepared by Ch-T and iodogen methods and The DPC kits. This may be extremely helpful in diagnosis and proper management of thyroid dysfunctions

  15. Human serum albumin homeostasis: a new look at the roles of synthesis, catabolism, renal and gastrointestinal excretion, and the clinical value of serum albumin measurements

    Directory of Open Access Journals (Sweden)

    Levitt DG

    2016-07-01

    Full Text Available David G Levitt,1,* Michael D Levitt2,* 1Department of Integrative Biology and Physiology, University of Minnesota, 2Research Service, Veterans Affairs Medical Center, Minneapolis, MN, USA *These authors contributed equally to this work Abstract: Serum albumin concentration (CP is a remarkably strong prognostic indicator of morbidity and mortality in both sick and seemingly healthy subjects. Surprisingly, the specifics of the pathophysiology underlying the relationship between CP and ill-health are poorly understood. This review provides a summary that is not previously available in the literature, concerning how synthesis, catabolism, and renal and gastrointestinal clearance of albumin interact to bring about albumin homeostasis, with a focus on the clinical factors that influence this homeostasis. In normal humans, the albumin turnover time of about 25 days reflects a liver albumin synthesis rate of about 10.5 g/day balanced by renal (≈6%, gastrointestinal (≈10%, and catabolic (≈84% clearances. The acute development of hypoalbuminemia with sepsis or trauma results from increased albumin capillary permeability leading to redistribution of albumin from the vascular to interstitial space. The best understood mechanism of chronic hypoalbuminemia is the decreased albumin synthesis observed in liver disease. Decreased albumin production also accounts for hypoalbuminemia observed with a low-protein and normal caloric diet. However, a calorie- and protein-deficient diet does not reduce albumin synthesis and is not associated with hypoalbuminemia, and CP is not a useful marker of malnutrition. In most disease states other than liver disease, albumin synthesis is normal or increased, and hypoalbuminemia reflects an enhanced rate of albumin turnover resulting either from an increased rate of catabolism (a poorly understood phenomenon or enhanced loss of albumin into the urine (nephrosis or intestine (protein-losing enteropathy. The latter may occur

  16. Serum LH-RF and LH levels after synthetic LH-RF administration in man as measured by radioimmunoassays

    International Nuclear Information System (INIS)

    Shiina, Masaki; Makino, Tsunehisa; Nakamura, Yukio; Iizuka, Rihachi

    1975-01-01

    Using a radioimmunoassay (RIA) which is sensitive and highly specific to lutenizing hormone releasing factors (LRF, LH-RF), diminution of an exogeously administered synthetic LH-RF in the blood and the movement of LH released into the blood from the anterior lobe of hypopysis were examined on healthy adult males. The blood LH-RF level after an intravenous administration of 200 μg of synthetic LH-RF reached a maximum (mean, 35.0 ng/ml serum) 2.5 minutes after administration, followed by a rapid decrease, and was as low as 1.0 ng/ml serum 30 minutes after administration. The diminution of the exogenous LH-RF from the blood was rapidest 2.5-15 minutes after administration (t1/2=3.9 minutes) and slowest (t1/2=7.9 minutes) 15-30 minutes after administration. On the other hand, when 200 μg of the synthetic LH-RF was administered intramuscularly, LH-RF appeared only slightly in the blood 2.5 minutes after administration, and the maximum level (10 minutes after administration) was only 1.6 ng/ml serum. It diminished from the blood drawing lenient curve. The blood LH level continued to rise significantly starting 5 minutes after administration of 200 μg of the synthetic LH-RF both in intravenous and intramuscular cases, showing hardly any differences between them. The blood endogenous LH-RF level prior to the synthetic LH-RF administration was below the measurable sensitivity (10 pg/tupe). (Mukohata, S.)

  17. Isolation and characterization of Wharton’s jelly-derived multipotent mesenchymal stromal cells obtained from bovine umbilical cord and maintained in a defined serum-free three-dimensional system

    Directory of Open Access Journals (Sweden)

    Cardoso Tereza C

    2012-05-01

    bovine-derived UC-WJ cells was included in the culture which demonstrated the immunossupression profile typically observed among isolated mesenchymal cells from other species. After classified the UC-WJ cells as mesenchymal stromal phenotype the in vitro 3D cultures was performed using the AlgiMatrix® protocol. Based on the size of spheroids (283,07 μm ± 43,10 μm we found that three weeks of culture was the best period to growth the UC-WJ cells on 3D dimension. The initial cell density was measured and the best value was 1.5 × 106 cells/well. Conclusions We described for the first time the isolation and characterization of UC-WJ cells in a serum-free condition and maintenance of primitive mesenchymal phenotype. The culture was stable under 60 consecutive passages with no genetic abnormalities and proliferating ratios. Taken together all results, it was possible to demonstrate an easy way to isolate and culture of bovine-derived UC-WJ cells under 2D and 3D serum-free condition, from fetal adnexa with a great potential in cell therapy and biotechnology.

  18. The measurement of TSH-receptor autoantibodies in human serum by radioreceptor assay

    International Nuclear Information System (INIS)

    Truong, T.X.

    2002-01-01

    182U/l(SD= 193.6U/l). Max of Graves' disease is 398.1U/l. Min of Grave's disease is 2.03U/l . The TRAB levels greater than 2.6 U/l are considered positive. The sensitivity of diagnosis is 90%, specificity is 96%, likelihood is 27, accuracy is 93%, prevalence is 50%, positive predictive value is 96%, negative predictive value is 90%. The study on 20 subject of Grave's disease after thyroidectomy, the range of TRAB concentration in serum are from 1.08 U/l to 37 U/l.The mean is 5.9 +/-1.25U/l. On 25 subjects of Grave's disease after antithyroid drugs treatment, the range of TRAB concentration in serum are from 0,42 U/l to 25 U/l.The mean is 5.28+/- 1.42U/l. Base on these results we could use that in the clinic for diagnosis, evaluation of treatment response and follow up after treatment of Grave's disease

  19. Using the Time-Lag-Correlation function of Dual-Aperture-Scintillometer measurements to obtain the Crosswind

    NARCIS (Netherlands)

    Dinther, van D.; Hartogensis, O.K.

    2014-01-01

    The wind component perpendicular to airport runways, the so-called crosswind (U⊥), introduces a safety risk for airplanes landing and taking off. The crosswind U⊥ on the runway is in general measured by cup anemometers and wind vanes, which are point measurements. The U⊥ measured by a scintillometer

  20. Measurement of FA and VitB{sub 12} in serum by TRFIA and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Jinhong, Zhou; Huimin, Wang [Affiliated Hospital of Nantong Univ., Nantong (China). Dept. of Laboratory Medicine

    2006-03-15

    To investigate the correlation between diseases and the quantity of folic acid(FA) and vitamine B{sub 12} (VitB{sub 12}) in serum, the quantity of FA and VitB{sub 12} in serum was measured by TR- FIA. The results showed that the levels of FA and VitB{sub 12} in 68 controlled subjects were 20.13{+-}5.72 nmol/L and 240.45{+-}58.23 pmol/L respectively. The levels of FA and VitB{sub 12} in 6 patients with megaloblastic anemia, 26 with medium-terminal gestation femineity, 7 with liver cirrhosis, 10 with gastric ulcerand 31 with cerebral infarction were significant lower than those in the control group. The level of FA in 24 with malignant hematopathy and 57 with malignant tumor was significantly lower but VitB{sub 12} between the 31 patients with iron deficiency anemia and 12 with CAA and the control group. The amount of the FA in 9 patients with chronic atrophic gastritis and 42 blood donors were lower than that in the control. The determination of FA and VitB{sub 12} levels may be quite significant in the diagnosis, therapy and prognosis of diseases. Laboratories should establish the reference values which fit the locals specifically. (authors)

  1. Serum Levels of sRAGE Are Associated with Body Measurements, but Not Glycemic Parameters in Patients with Prediabetes.

    Science.gov (United States)

    Guclu, Metin; Ali, Asuman; Eroglu, Derya Ustun; Büyükuysal, Sema Oral; Cander, Soner; Ocak, Nihal

    2016-02-01

    Our aim was to assess serum levels of the soluble receptor for advanced glycation end products (sRAGE) and to examine their association with anthropometric and metabolic parameters in patients with prediabetes and obese controls. The two study groups were composed of 42 patients with prediabetes and diabetic neuropathy and 42 age-, gender-, body weight (BW)-, and body mass index (BMI)-matched obese adults as the control group. Prediabetes was diagnosed by the following criteria issued by the American Diabetes Association: impaired fasting glucose [fasting plasma glucose (FPG) level of 100-125 mg/dL], impaired glucose tolerance (2 hr plasma glucose level of 140-199 mg/dL after a 75 grams oral glucose challenge), or a glycated hemoglobin (HbA1C) level of 5.7%-6.4%. There were no differences between the groups in terms of age, gender distribution, BW, or BMI. Despite these similarities, patients with prediabetes had higher FPG, HbA1c, and 2-hr postchallenge glucose levels, higher systolic and diastolic blood pressure, and larger waist and hip circumferences compared with the obese controls. Lipid measurements, complete blood counts, kidney and liver function tests, high-sensitivity C-reactive protein, and sRAGE levels were similar between the two groups. We found significant negative correlations between sRAGE levels and BW, BMI, waist and hip circumferences, waist-to-hip ratios, and low-density lipoprotein (LDL) cholesterol levels. There were no significant correlations with other parameters, including demographic, metabolic, and blood pressure measurements. In contrast to glycemic parameters, serum levels of sRAGE were negatively correlated with body measurements indicative of obesity in the prediabetic state. In addition, the negative correlation with LDL cholesterol levels suggests that sRAGE has a more robust association with metabolic syndrome than with prediabetes.

  2. Simultaneous measurement of total Estradiol and Testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry

    Science.gov (United States)

    Zhou, Hui; Wang, Yuesong; Gatcombe, Matthew; Farris, Jacob; Botelho, Julianne C.; Caudill, Samuel P.; Vesper, Hubert W.

    2017-01-01

    Reliable measurement of total testosterone and estradiol is critical for their use as biomarkers of hormone related disorders in patient care and translation research. We developed and validated a mass spectrometry method to simultaneously quantify these analytes in human serum without chemical derivatization. Serum is equilibrated with isotopic internal standards and treated with acidic buffer to release hormones from their binding proteins. Lipids are isolated and polar impurities are removed by two serial liquid-liquid extraction steps. Total testosterone and estradiol are measured using liquid chromatography tandem mass spectrometry (LC-MS/MS) in combination of positive and negative electrospray ionization modes. The method shows broad analytical measurement range for both testosterone 0.03–48.5 nM (0.75–1400 ng/dL) and estradiol 11.0–5138 pM (2.99–1400 pg/mL) and excellent agreement with certified reference materials (mean bias less than 2.1% to SRM 971, BCR 576, 577, and 578) and a high order reference method (mean bias 1.25% for testosterone and −0.84% for estradiol). The high accuracy of the method was monitored and certified by CDC Hormone Standardization (HoSt) Program for two years with mean bias −0.7% (95%CI: −1.6% to 0.2%) for testosterone and 0.1% (95%CI: −2.2% to 2.3%) for estradiol. The method precision over a 2-year period for Quality Control pools at low, medium and high concentrations was 2.7–2.9% for testosterone and 3.3–5.3% for estradiol. With the consistently excellent accuracy and precision, this method is readily applicable for high-throughput clinical and epidemiological studies. PMID:28801832

  3. Factors Influencing the Measurement of Plasma/Serum Surfactant Protein D Levels by ELISA

    OpenAIRE

    Bratcher, Preston E.; Gaggar, Amit

    2014-01-01

    BACKGROUND: Extensive variations in human surfactant protein D (SP-D) levels in circulation as measured by ELISA exist in the published literature. In order to determine the source of these variations, factors influencing the measurement by ELISA were explored. MATERIALS AND METHODS: Peripheral blood from healthy individuals was collected into various vacutainers during the same blood draw. Recombinant SP-D was diluted into different matrices and used for a standard curve. Samples were analyz...

  4. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis.

    Science.gov (United States)

    Stöckl, Dietmar; Sluss, Patrick M; Thienpont, Linda M

    2009-10-01

    The divergence in analytical quality of serum/plasma 25-hydroxy-vitamin D analysis calls for defining specifications for a reference measurement system. Fundamentally, in a reference measurement system, there should be a relationship between the analytical specifications for higher- (reference) and lower-order (routine) measurements. Therefore, when setting specifications, we started with limits for routine imprecision (CV(rou)) and bias (B(rou)) using 4 models: (1) the misclassifications in diagnosis, (2) biological variation data (reference interval (RI) and monitoring), (3) expert recommendations, and (4) state-of-the-art performance. Then, we used the derived goals to tailor those for reference measurements and certified reference materials (CRMs) for calibration by setting the limits for CV(ref) at 0.5 CV(rou), B(ref) at 0.33 B(rou)(,) max. uncertainty (U(max)) at 0.33 B(ref). The established specifications ranged between CV(rou)model 3) and CV(rou)model 2, monitoring). Model 2 (monitoring) gave the most stringent goals, model 3, the most liberal ones. Accounting for state-of-the-art performance and certification capabilities, we used model 2 (RI) to recommend achievable goals: for routine testing, CV(rou)measurements, CV(ref)

  5. Feasibility of Obtaining Measures of Lifestyle From a Smartphone App: The MyHeart Counts Cardiovascular Health Study.

    Science.gov (United States)

    McConnell, Michael V; Shcherbina, Anna; Pavlovic, Aleksandra; Homburger, Julian R; Goldfeder, Rachel L; Waggot, Daryl; Cho, Mildred K; Rosenberger, Mary E; Haskell, William L; Myers, Jonathan; Champagne, Mary Ann; Mignot, Emmanuel; Landray, Martin; Tarassenko, Lionel; Harrington, Robert A; Yeung, Alan C; Ashley, Euan A

    2017-01-01

    Studies have established the importance of physical activity and fitness, yet limited data exist on the associations between objective, real-world physical activity patterns, fitness, sleep, and cardiovascular health. To assess the feasibility of obtaining measures of physical activity, fitness, and sleep from smartphones and to gain insights into activity patterns associated with life satisfaction and self-reported disease. The MyHeart Counts smartphone app was made available in March 2015, and prospective participants downloaded the free app between March and October 2015. In this smartphone-based study of cardiovascular health, participants recorded physical activity, filled out health questionnaires, and completed a 6-minute walk test. The app was available to download within the United States. The feasibility of consent and data collection entirely on a smartphone, the use of machine learning to cluster participants, and the associations between activity patterns, life satisfaction, and self-reported disease. From the launch to the time of the data freeze for this study (March to October 2015), the number of individuals (self-selected) who consented to participate was 48 968, representing all 50 states and the District of Columbia. Their median age was 36 years (interquartile range, 27-50 years), and 82.2% (30 338 male, 6556 female, 10 other, and 3115 unknown) were male. In total, 40 017 (81.7% of those who consented) uploaded data. Among those who consented, 20 345 individuals (41.5%) completed 4 of the 7 days of motion data collection, and 4552 individuals (9.3%) completed all 7 days. Among those who consented, 40 017 (81.7%) filled out some portion of the questionnaires, and 4990 (10.2%) completed the 6-minute walk test, made available only at the end of 7 days. The Heart Age Questionnaire, also available after 7 days, required entering lipid values and age 40 to 79 years (among 17 245 individuals, 43.1% of participants). Consequently, 1334 (2

  6. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  7. Measurement of monoterpenes and sesquiterpenes in serum, plasma, and rumen fluid from sheep

    Science.gov (United States)

    Studies involving the consumption, metabolism, and elimination of terpenes by small ruminants consuming terpene-laden shrubs as well as those exploring the potential for natural products as rumen modifiers could benefit from a procedure that measures terpenes in both blood and rumen fluid and that i...

  8. The significance of measuring serum IGF1, IGFBP3 and OST for the judgement of abnormal skeletal development and therapeutic monitoring in precocious children

    International Nuclear Information System (INIS)

    Ji Zhiying; Zhao Ruifang; Lv Xiaomei; Gu Fanlei; Cai Depei

    2004-01-01

    Objective: To study the value of measuring serum insulin-like growth factor I (IGF 1 ), insulin-like growth factor binding protein III (IGFBP 3 ) and osteocalcin (OST) for evaluating acceleration of skeletal growth and skeletal maturity, and its value for therapeutic monitoring in precocious children. Methods: Serum IGF 1 and IGFBP 3 were measured with immunoradiometric assay, serum OST was measured with radioimmunoassay in 117 girls with idiopathic precocious puberty. The girls were grouped according to age, and various parameters collected from them were compared with normal values of matched girls. Furthermore, the girls were grouped according to Tanner's staging (the extent of precocious puberty), the analysis of correlativity between various parameters to the extent of precocious puberty was performed, and the analysis of correlativity between the level of serum IGF 1 and advancing of bone age was performed. Various parameters were measured once more in 38 of the study girls after six months of the treatment, and the parameters were compared with that before treatment. Results: 1) The levels of serum IGF 1 and OST in the girls with precocious puberty were elevated obviously than that in matched normal girls, but the level of serum IGFBP 3 was reduced obviously than that in matched normal girls. It was demonstrated that typical elevation of serum IGF 1 and OST occurred in normal adolescence appeared ahead of time in the girls with precocious puberty. 2) The extent of precocious puberty correlated closely with the level of serum IGF 1 (r=0.489, P 1 (r=0.411, P 1 was. 3) After the treatment, the concentration of serum IGF 1 reduced from (455.52 ± 119.45) μg/L to (284.55 ± 99.52) μg/L (P 1 and OST reduced obviously. Conclusions: Serum IGF 1 and OST could act as quantitative parameters for evaluating acceleration of skeletal growth and advancing of skeletal maturity in girls with idiopathic true precocious puberty. It could act as a parameter for therapeutic

  9. Mercury concentration in maternal serum, cord blood, and placenta in patients with amalgam dental fillings: effects on fetal biometric measurements.

    Science.gov (United States)

    Bedir Findik, Rahime; Celik, Huseyin Tugrul; Ersoy, Ali Ozgur; Tasci, Yasemin; Moraloglu, Ozlem; Karakaya, Jale

    2016-11-01

    We aimed to determine the extent to which mercury is transmitted from the mother to fetus via the umbilical cord in patients with amalgam dental fillings, and its effect on fetal biometric measurements. Twenty-eight patients as the study group with amalgam fillings, and 32 of them as the control group were included in this prospective case-control study. The mercury levels were measured in the maternal and cord venous sera, and the placental samples. Two groups were compared in terms of these and the fetal/neonatal biometric measurements. In the study group, the maternal and umbilical cord mercury levels were found to be significantly higher than those from the control group (p = 0.006 and p = 0.010, respectively). These high levels did not affect the fetal biometric measurements. The presence of high serum mercury levels in pregnant women with amalgam fillings is important, and warrants further long-term studies in order to investigate the fetal neurological effects as well.

  10. Silver micro- and nano-particles obtained using different glycols as reducing agents and measurement of their conductivity

    Directory of Open Access Journals (Sweden)

    Moudir Naïma

    2016-01-01

    Full Text Available Synthesis of silver micro- and nano-particles for the preparation of conductive pastes for the metallization of solar cells was realized by chemical reduction in the presence and absence of poly(vinyl-pyrrolidone (PVP. Silver nitrate was used as a precursor in the presence of three polyols (ethylene glycol, di-ethylene glycol and propylene glycol tested at experimental temperatures near their boiling points. Six samples were obtained by this protocol. Three silver powders obtained without the use of PVP have a metallic luster appearance; however, the samples produced using an excess of PVP are in the form of stable colloidal dispersions of silver nano-particles. Structural characterizations of samples using a scanning electron microscope and X-ray diffractometer show a good crystallinity and spherical morphology. From DSC and TGA analyses, it was noticed that all the nano-silvers present in the colloidal suspension have the same thermal behavior.

  11. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  12. The Association of Serum Total Peptide YY (PYY) with Obesity and Body Fat Measures in the CODING Study.

    Science.gov (United States)

    Cahill, Farrell; Ji, Yunqi; Wadden, Danny; Amini, Peyvand; Randell, Edward; Vasdev, Sudesh; Gulliver, Wayne; Sun, Guang

    2014-01-01

    PYY is an appetite suppressing hormone. Low circulating PYY has been linked to greater BMI. However data is controversial and this association has not been verified in large human populations. The purpose of this study was to investigate if fasting serum total PYY is associated with obesity status and/or adiposity at the population level. A total of 2094 subjects (Male-523, Female-1571) participated in this investigation. Total PYY was measured in fasting serum by enzyme-linked immunosorbent assay. Obesity status (NW-normal-weight, OW-overweight and OB-obese) was determined by the Bray Criteria according to body fat percentage measured by dual-energy x-ray absorptiometry and the WHO criteria according to BMI. One-way ANOVA and multiple regression was used to assess the adiposity-specific association between PYY and the following; weight, BMI, waist-circumference, hip-circumference, waist-hip ratio, percent body fat (%BF), trunk fat (%TF), android fat (%AF) and gynoid fat (%GF). PYY was not significantly different among NW, OW and OB groups defined by neither %BF nor BMI for both men and women. However among women, fasting PYY was positively associated with adiposity measures. Women with the highest (Top 33%) waist-circumference, %BF and %TF had significantly higher PYY (10.5%, 8.3% and 9.2% respectively) than women with the lowest (Bottom 33%). Age, smoking, medication use and menopause were all positively associated with PYY levels in women but not in men. To our knowledge this is the largest population based study, with the most comprehensive analysis and measures of confounding factors, to explore the relationship of circulating PYY with obesity. Contrary to initial findings in the literature we discovered that PYY was positively associated with body fat measures (waist-circumference, %BF and %TF) in women. Although the effect size of the positive association of PYY with obesity in women is small, and potentially negligible, it may in fact represent a protective

  13. Clinical significance of measurement of changes of serum IL-2, SIL-2R levels after treatment in patients with thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Feng Yue

    2005-01-01

    Objective: To study the changes of serum IL-2 and SIL-2R levels after treatment in 31 patients with thrombocytopenic purpura. Methods: Serum IL-2 (with RIA) and SIL-2R (with ELISA) levels were measured in 31 patients with thrombocytopenic purpura both before and after treatment as well as in 35 controls. Results: Before treatment, in the patients the serum IL-2 levels were significantly lower and serum SIL-2R levels were significantly higher than those in the controls ( P 0.05). Conclusion: Cytokines IL-2 and SIL-2R levels changes could reflect the immunostatus of the patients as well as the progress of diseases and could be of prognostic values. (authors)

  14. Clinical significance of measurement of plasma leptin and serum IL-6, IL-18 levels after treatment in patients with children nephrotic syndrome

    International Nuclear Information System (INIS)

    Wang Xiaoyan

    2011-01-01

    Objective: To explore the clinical significance of changes of plasma leptin and serum IL-6, IL-18 levels after treatment in patients with children nephrotic syndrome. Methods: Plasma leptin (with RIA) serum IL-6, IL-18 (with ELISA) levels were measured in 31 patients with children nephrotic syndrome both before and after treatment as well as in 30 controls. Results: Before treatment,the plasma leptin and serum IL-6, IL-18 levels were significantly higher than those in controls(P <0.01). After treatment for 3 months, the levels in patients though dropped markedly remained significantly higher than those in controls (P<0.05). Plasma leptin levels were positively correlated with IL-6, IL-18 levels (r=0.6138, 0.5784, P<0.01). Conclusion: Changes of plasma leptin and serum IL-6, IL-18 levels after treatment might be of prognostic importance in patients with children nephrotic syndrome. (authors)

  15. Clinical significance of measurement of changes of serum IGF-II and NO levels after treatment in elderly patients with chronic bronchitis

    International Nuclear Information System (INIS)

    Gu Tao

    2006-01-01

    Objective: To study the clinical significance of changes of serum IGF-II and NO levels after treatment in elderly patients with chronic bronchitis. Methods: Serum IGF-II (with RIA) and NO (with Biochemical method) levels were measured in 42 elderly patients with chronic bronchitis both before and after treatment as well as in 30 controls. Results: Before treatment in the patients the serum IGF-II levels were significantly higher than those in controls (P<0.01), while the NO levels were significantly lower (P<0.01). After two weeks of treatment, the levels though dropped markedly, lemained higher than those in controls (P<0. 05). Conclusion: Serum IGF-II and NO levels changes could reflect the disease status as well as the progress of diseases. (authors)

  16. Clinical significance of measurement of changes of serum NSE and plasma NPY levels after treatment in pediatric patients with viral encephalitis

    International Nuclear Information System (INIS)

    Jin Bo; Zheng Guo

    2007-01-01

    Objective: To explore the significance ef changes of serum NSE and plasma NPY levels after treatment in pediatric patients with viral encephalitis. Methods: Serum NSE and plasma NPY levels were measured with RIA in 32 pediatric patients with viral encephalitis both before and after treatment as well as in 30 controls. Results: Before treatment, in the patients, the serum NSE and plasma NPY levels were significantly higher than those in controls (P<0.01). After 1 month's treatment the levels dropped markedly but still remained significantly higher than those in controls (P<0.05). Conclusion: Serum NSE and plasma NPY levels changes were closely related to the progress of viral encephalitis. (authors)

  17. Clinical significance of measurement of changes of serum IL-2, SIL-2R levels after chemotherapy in patients with lung carcinoma

    International Nuclear Information System (INIS)

    Lu Men; Duo Huanzhi; Luo Guorong

    2004-01-01

    Objective: To study the changes of serum IL-2 and SIL-2R levels after chemotherapy in 36 patients with lung carcinoma. Methods: Serum IL-2 (with RIA) and SIL-2R (with ELISA) levels were measured in 36 patients with lung carcinoma both before and after chemotherapy as well as in 35 controls. Results: Before chemotherapy, in the patients the serum IL-2 levels were significantly lower and serum SIL-2R levels were significantly higher than those in the controls (P<0.01). Six months after chemotherapy, those patients without recurrence (n=20) had their IL-2 and SIL-2R levels returned to normal but in those with recurrences (n=12) the levels were about the same as before. Conclusion: Cytokines IL-2 and SIL-2R levels changes could reflect the immunostatus of the patient as well as the progress of disease and could be of prognostic value. (authors)

  18. Comparison of ambient aerosol extinction coefficients obtained from in-situ, MAX-DOAS and LIDAR measurements at Cabauw

    Directory of Open Access Journals (Sweden)

    P. Zieger

    2011-03-01

    Full Text Available In the field, aerosol in-situ measurements are often performed under dry conditions (relative humidity RH<30–40%. Since ambient aerosol particles experience hygroscopic growth at enhanced RH, their microphysical and optical properties – especially the aerosol light scattering – are also strongly dependent on RH. The knowledge of this RH effect is of crucial importance for climate forcing calculations or for the comparison of remote sensing with in-situ measurements. Here, we will present results from a four-month campaign which took place in summer 2009 in Cabauw, The Netherlands. The aerosol scattering coefficient σsp(λ was measured dry and at various, predefined RH conditions between 20 and 95% with a humidified nephelometer. The scattering enhancement factor f(RH,λ is the key parameter to describe the effect of RH on σsp(λ and is defined as σsp(RH,λ measured at a certain RH divided by the dry σsp(dry,λ. The measurement of f(RH,λ together with the dry absorption measurement (assumed not to change with RH allows the determination of the actual extinction coefficient σep(RH,λ at ambient RH. In addition, a wide range of other aerosol properties were measured in parallel. The measurements were used to characterize the effects of RH on the aerosol optical properties. A closure study showed the consistency of the aerosol in-situ measurements. Due to the large variability of air mass origin (and thus aerosol composition a simple parameterization of f(RH,λ could not be established. If f(RH,λ needs to be predicted, the chemical composition and size distribution need to be known. Measurements of four MAX-DOAS (multi-axis differential optical absorption spectroscopy instruments were used to retrieve vertical profiles of σep(λ. The values of the lowest layer were compared to the in-situ values after conversion of the latter ones to ambient

  19. A novel method for direct measurement of complement convertases activity in human serum.

    Science.gov (United States)

    Blom, A M; Volokhina, E B; Fransson, V; Strömberg, P; Berghard, L; Viktorelius, M; Mollnes, T E; López-Trascasa, M; van den Heuvel, L P; Goodship, T H; Marchbank, K J; Okroj, M

    2014-10-01

    Complement convertases are enzymatic complexes that play a central role in sustaining and amplification of the complement cascade. Impairment of complement function leads directly or indirectly to pathological conditions, including higher infection rate, kidney diseases, autoimmune- or neurodegenerative diseases and ischaemia-reperfusion injury. An assay for direct measurement of activity of the convertases in patient sera is not available. Existing assays testing convertase function are based on purified complement components and, thus, convertase formation occurs under non-physiological conditions. We designed a new assay, in which C5 blocking compounds enabled separation of the complement cascade into two phases: the first ending at the stage of C5 convertases and the second ending with membrane attack complex formation. The use of rabbit erythrocytes or antibody-sensitized sheep erythrocytes as the platforms for convertase formation enabled easy readout based on measurement of haemolysis. Thus, properties of patient sera could be studied directly regarding convertase activity and membrane attack complex formation. Another advantage of this assay was the possibility to screen for host factors such as C3 nephritic factor and other anti-complement autoantibodies, or gain-of-function mutations, which prolong the half-life of complement convertases. Herein, we present proof of concept, detailed description and validation of this novel assay. © 2014 British Society for Immunology.

  20. Proliferative effect of whey from cow's milk obtained at two different stages of pregnancy measured in MCF-7 cells

    DEFF Research Database (Denmark)

    Nielsen, Tina S; Andersen, Charlotte; Sejrsen, Kristen

    2012-01-01

    Dietary estrogens may play a role in the etiology of hormone-dependent cancers like breast cancer. Cow's milk contains various endogenous estrogens and feed derived phytoestrogens that potentially contribute to an estrogenic effect of milk in consumers, and therefore we evaluated the effect of milk...... (whey) in a proliferation assay with estrogen-sensitive MCF-7 human breast cancer cells. Milk samples were obtained from 22 cows representing different stages of pregnancy (first and second half) and whey was produced from the milk. 0·1, 0·25 or 0·5% whey was included in the cell culture medium...

  1. Description of analytical method and clinical utility of measuring serum 7-alpha-hydroxy-4-cholesten-3-one (7aC4) by mass spectrometry.

    Science.gov (United States)

    Donato, Leslie J; Lueke, Alan; Kenyon, Stacy M; Meeusen, Jeffrey W; Camilleri, Michael

    2018-02-01

    Imbalance of bile acids (BA) homeostasis in the gastrointestinal tract can lead to chronic diarrhea or constipation when BA in the colon are in excess or low, respectively. Since both disturbances of bowel function can result from other etiologies, identifying BA imbalance is important to tailor treatment strategies. Serum concentrations of 7-alpha-hydroxy-4-cholesten-3-one (7aC4), a precursor in bile acid synthesis, reflect BA homeostasis. Here we describe a method to accurately measure serum 7aC4 and evaluate the clinical utility in patients with diarrhea or constipation phenotypes. Serum 7aC4 is measured after acetonitrile protein precipitation using C18 liquid chromatography, tandem mass spectrometry, and deuterium-labeled 7aC4 internal standard. Assay performance including linearity, precision, and accuracy was assessed using waste serum samples. The reference interval was established in healthy individuals without BA-altering conditions or medications. Clinical performance was assessed in patients with irritable bowel syndrome. The method precisely and accurately measured 7aC4 in human serum from 1.4-338ng/mL with no ion suppression or interference from related 7-keto-cholesterol. Central 95th percentile reference interval was 2.5-63.2ng/mL. Lower serum 7aC4 was found in patients with constipation with sensitivity/specificity of 79%/55% compared to healthy controls. Higher 7aC4 was found in patients with bile acid diarrhea (BAD) compared to those without BAD with sensitivity/specificity of 82%/53%. We have developed a sensitive and precise assay for measuring the concentration of 7aC4 in serum. The assay can be used to screen for diarrhea caused by bile acid malabsorption. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Creatinine generation from kinetic modeling with or without postdialysis serum creatinine measurement: results from the HEMO study.

    Science.gov (United States)

    Daugirdas, John T; Depner, Thomas A

    2017-11-01

    A convenient method to estimate the creatinine generation rate and measures of creatinine clearance in hemodialysis patients using formal kinetic modeling and standard pre- and postdialysis blood samples has not been described. We used data from 366 dialysis sessions characterized during follow-up month 4 of the HEMO study, during which cross-dialyzer clearances for both urea and creatinine were available. Blood samples taken at 1 h into dialysis and 30 min and 60 min after dialysis were used to determine how well a two-pool kinetic model could predict creatinine concentrations and other kinetic parameters, including the creatinine generation rate. An extrarenal creatinine clearance of 0.038 l/kg/24 h was included in the model. Diffusive cross-dialyzer clearances of urea [230 (SD 37 mL/min] correlated well (R2 = 0.78) with creatinine clearances [164 (SD 30) mL/min]. When the effective diffusion volume flow rate was set at 0.791 times the blood flow rate for the cross-dialyzer clearance measurements at 1 h into dialysis, the mean calculated volume of creatinine distribution averaged 29.6 (SD 7.2) L], compared with 31.6 (SD 7.0) L for urea (P creatinine generation rate [1183 (SD 463) mg/day] averaged 100.1 % (SD 29; median 99.3) of that predicted in nondialysis patients by an anthropometric equation. A simplified method for modeling the creatinine generation rate using the urea distribution volume and urea dialyzer clearance without use of the postdialysis serum creatinine measurement gave results for creatinine generation rate [1187 (SD 475) mg/day; that closely matched the value calculated using the formally modeled value, R2 = 0.971]. Our analysis confirms previous findings of similar distribution volumes for creatinine and urea. After taking extra-renal clearance into consideration, the creatinine generation rate in dialysis patients is similar to that in nondialysis patients. A simplified method based on urea clearance

  3. Comparison of ambient aerosol extinction coefficients obtained from in-situ, MAX-DOAS and LIDAR measurements at Cabauw

    NARCIS (Netherlands)

    Zieger, P.; Weingartner, E.; Henzing, J.; Moerman, M.; Leeuw, G. de; Mikkilä, J.; Ehn, M.; Petäjä, T.; Clémer, K.; Roozendael, M. van; Yilmaz, S.; Frieß, U.; Irie, H.; Wagner, T.; Shaiganfar, R.; Beirle, S.; Apituley, A.; Wilson, K.; Baltensperger, U.

    2011-01-01

    In the field, aerosol in-situ measurements are often performed under dry conditions (relative humidity RH<30-40%). Since ambient aerosol particles experience hygroscopic growth at enhanced RH, their microphysical and optical properties especially the aerosol light scattering are also strongly

  4. Relationship of Serum Vitamin D Concentrations and Allostatic Load as a Measure of Cumulative Biological Risk among the US Population: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Regina Frei

    Full Text Available The allostatic load (AL index is a multi-systemic measure of physiologic dysregulation known to be associated with chronic exposure to stress and adverse health outcomes. We examined the relationship between AL and serum 25-hydroxyvitamin D (25(OHD concentration in non-institutionalized US adults.Data from the Third National Health and Nutrition Examination Survey (NHANES III, 1988-94 were used to calculate two versions of AL including 9 biomarkers and another two with 14 biomarkers (systolic and diastolic blood pressure, pulse rate, serum cholesterol, serum HDL-cholesterol, glycated hemoglobin, sex-specific waist-to-hip ratio, serum albumin, and serum C-reactive protein for AL1, and, additionally body mass index, serum triglyceride, serum creatinine, and serum herpes I & II antibodies for AL2, each set defined by predefined cut-offs or by quartiles. Serum vitamin D concentration was ranked into quartiles. Logistic regression, Poisson regression and linear regression were used to examine the association of serum 25(OHD concentrations on AL, after adjusting for biological, physiological, socioeconomic, lifestyle, and health variables.Odds Ratios (OR for high AL of the lowest 25(OHD serum quartile were between 1.45 (95% CI: 1.28, 1.67 and 1.79 (95% CI: 1.39, 2.32 for the fully adjusted model, depending on AL version. Inverse relationships between vitamin D serum concentrations were observed for all AL versions and every adjustment. This relationship was consistent after stratification by sex, age or ethnic background. Sensitivity to low 25(OHD concentrations was highest among the youngest group (20-39 years with an OR of 2.11 (95% CI: 1.63, 2.73 for the lowest vitamin D quartile Q1.Vitamin D had a consistent and statistically significant inverse association with all tested models of high AL, which remained consistent after adjusting for biological, socioeconomic, lifestyle and health variables. Our study adds evidence linking low 25(OHD

  5. Measuring surface topography with scanning electron microscopy. I. EZEImage: a program to obtain 3D surface data.

    Science.gov (United States)

    Ponz, Ezequiel; Ladaga, Juan Luis; Bonetto, Rita Dominga

    2006-04-01

    Scanning electron microscopy (SEM) is widely used in the science of materials and different parameters were developed to characterize the surface roughness. In a previous work, we studied the surface topography with fractal dimension at low scale and two parameters at high scale by using the variogram, that is, variance vs. step log-log graph, of a SEM image. Those studies were carried out with the FERImage program, previously developed by us. To verify the previously accepted hypothesis by working with only an image, it is indispensable to have reliable three-dimensional (3D) surface data. In this work, a new program (EZEImage) to characterize 3D surface topography in SEM has been developed. It uses fast cross correlation and dynamic programming to obtain reliable dense height maps in a few seconds which can be displayed as an image where each gray level represents a height value. This image can be used for the FERImage program or any other software to obtain surface topography characteristics. EZEImage also generates anaglyph images as well as characterizes 3D surface topography by means of a parameter set to describe amplitude properties and three functional indices for characterizing bearing and fluid properties.

  6. Cephalometric analysis for the diagnosis of sleep apnea: a comparative study between reference values and measurements obtained for Brazilian subjects

    Directory of Open Access Journals (Sweden)

    Patrícia Superbi Lemos Maschtakow

    2013-06-01

    Full Text Available OBJECTIVE: To verify if the reference values of Sleep Apnea cephalometric analysis of North American individuals are similar to the ones of Brazilian individuals presenting no craniofacial anomalies. The study also aimed to identify craniofacial alterations in Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS patients in relation to individuals without clinical characteristics of the disease through this cephalometric analysis. METHOD: It were used 55 lateral cephalograms consisting of 29 for the control group of adult individuals without clinical characteristics of OSAHS and 26 apneic adults. All radiographs were submitted to Sleep Apnea cephalometric analysis through Radiocef Studio 2.0. The standard values of this analysis were compared, by means of z test, to the ones obtained from the control group and these were compared to values from apneic group through Student's t test. RESULTS: There were no significant differences between values obtained from control group and standard values. On the group of OSAHS patients it was observed a decrease on the dimensions of upper airways and an increase on the soft palate length. CONCLUSIONS: The standard values of Sleep Apnea analysis can be used as reference in Brazilian individuals. Besides, through lateral cephalograms it was possible to identify craniofacial alterations in OSAHS patients.

  7. Modeling Serum Creatinine in Septic ICU Patients

    DEFF Research Database (Denmark)

    De Gaetano, Andrea; Cortese, Giuliana; Pedersen, Morten Gram

    2004-01-01

    Serum creatinine is a metabolite assumed to be constantly produced by the normally functioning muscle mass and is a good measure for monitoring daily renal function in the intensive care unit (ICU). High serum creatinine levels or an abnormal departure from normal pre-disease basal levels....... The present work details the structure of a model describing observed creatinine serum concentration (CSC) variations, depending on the time-varying septic insult to renal function in ICU patients, as well as the estimation of its parameters. CSC determinations were routinely obtained from 12 patients...

  8. Comparative study between 99Tcm-MDP renal dynamic imaging and measurement of serum cystatin C in evaluation of glomerular function

    International Nuclear Information System (INIS)

    Ji Zeqiang; Miao Weibing

    2010-01-01

    Objective: To compare the difference between 99 Tcm-diethylenetriaminepentaacetic acid ( 99 Tc m -DTPA) renal dynamic imaging and measurement of serum cystatin C in evaluation of glomerular filtration rate (GFR). Methods: One hundred patients were selected at random, 38 cases with hypertension, 35 with nephrosis, 10 with arteriosclerosis obliterans, 9 with diabetes and 8 with other diseases. Evaluation of patients' GFR was made separately by 99 Tc m -DTPA renal dynamic imaging and measurement of serum cystatin C. Results: No significant difference of GFR was found between the two methods (t=1.591, P>0.05 ), and linear correlation was showed as well (r=0.809, P 99 Tc m -DTPA renal dynamic imaging could reveal the individual renal function and provide a more comprehensive evaluation of renal function while the measurement of serum cystatin C was simple and convenient, timesaving, economic, and more suit-able for screening patients' renal function clinically. (authors)

  9. Serum measurement of muscle and oxidative damage in soccer players after a game DOI: 10.5007/1980-0037.2010v12n4p269

    Directory of Open Access Journals (Sweden)

    Cláudio Teodoro Souza

    2010-01-01

    Full Text Available Futsal is a sport that requires sudden acceleration and deceleration with abrupt changes in direction. The marked impacts experienced by futsal players lead to muscle and oxidative damage. The objective of this study was to evaluate the serum levels of markers of muscle and oxidative damage in futsal players after a game. Six players with a mean age of 21.2 ± 0.98 years, weight of 67.1 ± 5.5 kg and height of 171.0 ± 0.07 cm participated in this study. Measurements were obtained 30 minutes before game 1 (pre-game, immediately after game 1 (post-game 1, and immediately after a second game (post-game 2, which was performed 24 hours after game 1. Serum was collected for the evaluation of creatine kinase and of damage to proteins and lipids. Creatine kinase concentrations, lipid peroxidation (xylenol and protein carbonylation were significantly higher after games 1 and 2 when compared to pre-game values. Sulfhydryl levels were lower after the end of games 1 and 2 compared to pre-game values. No difference in any of the parameters analyzed was observed between post-game 1 and post-game 2. Taken together, the results demonstrate that a futsal match provokes muscle and oxidative damage. Surprisingly, no increase in the parameters studied was observed after game 2. In view of the limited knowledge about the time of recovery after a futsal match, this study may provide important information to professionals working with this sport.

  10. The Reliability of Clinical Measurements of Forward Bending Obtained by the Use of the Modified Fingertip-to-Floor Method

    Science.gov (United States)

    1989-08-18

    Calabro, 1982; Macrae & Wright, 1969) and other forms of arthritis (Schober, 1937). Clinicians also use measurements of lumbar flexion to help determine...Clinical Biomechanics, 1, 20-26. Buswell, J. (1982). Low back pain: A comparison of two treatment programmes. New Zealand Journal of Physiotherapy ...Gilles, J., Haldeman, J. & Patterson, C. (1975). Low back pain: A study of 50 patients on a group exercise program. Physiotherapy Canada, 27. 71-77

  11. Optical Properties of the Urban Aerosol Particles Obtained from Ground Based Measurements and Satellite-Based Modelling Studies

    Directory of Open Access Journals (Sweden)

    Genrik Mordas

    2015-01-01

    Full Text Available Applications of satellite remote sensing data combined with ground measurements and model simulation were applied to study aerosol optical properties as well as aerosol long-range transport under the impact of large scale circulation in the urban environment in Lithuania (Vilnius. Measurements included the light scattering coefficients at 3 wavelengths (450, 550, and 700 nm measured with an integrating nephelometer and aerosol particle size distribution (0.5–12 μm and number concentration (Dpa > 0.5 μm registered by aerodynamic particle sizer. Particle number concentration and mean light scattering coefficient varied from relatively low values of 6.0 cm−3 and 12.8 Mm−1 associated with air masses passed over Atlantic Ocean to relatively high value of 119 cm−3 and 276 Mm−1 associated with South-Western air masses. Analysis shows such increase in the aerosol light scattering coefficient (276 Mm−1 during the 3rd of July 2012 was attributed to a major Sahara dust storm. Aerosol size distribution with pronounced coarse particles dominance was attributed to the presence of dust particles, while resuspended dust within the urban environment was not observed.

  12. Routine measurement of serum calcitonin in patients with nodular thyroid disorders?

    International Nuclear Information System (INIS)

    Dietlein, M.; Schmidt, M.; Schicha, H.; Wieler, H.; Schwab, R.; Goretzki, P.E.

    2008-01-01

    In spite of the fact that the German Society of Endocrinology has recommended calcitonin as screening-parameter the majority of physicians in Germany do not routinely use calcitonin in patients with thyroid nodules to exclude medullary thyroid cancer (MTC). The future revision of the recommendation should describe reference values for each commercially available assay, separately for men and women (basal and after pentagastrin-stimulation), and should define sonomorphological inclusion criteria. The epidemiological database of the prevalence of MTC is controversial and the specificity of basal elevated calcitonin levels is limited up to the 5-fold of the upper reference level. If renal insufficiency, bacterial infection, and an alcohol- or druginduced stimulation of calcitonin is excluded, hypercalcitoninaemia should be confirmed by a second measurement (if necessary using another assay). Stimulation of calcitonin by use of pentagastrin is mandatory prior to the decision on thyroidectomy. A stimulated calcitonin level < 100 pg/ml justifies 'wait and see'. If stimulated calcitonin levels range between 100 and 200 pg/ml or higher, the differentiation between C-cell hyperplasia and MTC remains uncertain, especially in men. The implementation of calcitonin- screening requires the definition of sonographic inclusion criteria and validation of each assay. Additional prerequisites are excellent logistic (short period between blood sampling and start of the laboratory test), knowledge of differential diagnoses, knowledge of the consumption of drugs and alcohol, availability of pentagastrin-testing and of moleculargenetic testing with full information to the patients and sufficient time before the decision on surgery is made. All this and the choice of a skilled surgeon, experienced in thyroidectomy and lymphadenectomy with a low rate of local complications are the rationale to recommend calcitonin-screening primarily in centers for thyroid disorders. (orig.)

  13. Effect of low level Doses of fast neutrons on the toxicity of snake venom through measuring some biophysical properties of blood serum of rats

    International Nuclear Information System (INIS)

    Hanafy, M.S.; Metwali, R.

    2001-01-01

    This study was conducted to investigate the effect of low level doses of fission neutrons from Cf 252 source on sublethal doses (low medium) of snake venom cerastes cerastes by injecting albino eats with unirradiated or irradiated venom and measuring the biophysical alterations in the blood serum of the rats. The biophysical properties of the total serum proteins were studied through measuring their dielectric relaxation and the electric conductivity in the frequency range 0.1→5 MHz at 4 degree C. The absorption spectra of the extracted total serum protein were also measured. The results indicated that there are pronounced changes in the molecular constructions of the total serum protein such as the molecular radii, shape, the relaxation time and dielectric increment for the rats injected with unirradiated venom but for the rats injected with irradiated venom (3x10 8 n/cm 2 ) corresponding values approach the control value. These changes in the molecular constructions of the total serum protein indicate changes in its biochemical properties. This fact was revealed in a previous work, where the irradiation with the fast neutrons were found to decrease the toxicity of the venom

  14. Clinical significance of measurements of changes of serum IL-2, SIL-2R and TNF-α levels after treatment in patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Yu Songsan

    2007-01-01

    Objective: To study the changes of serum IL-2, SIL-2R and TNF-α levels after treatment in 39 patients with rheumatoid arthritis. Methods: Serum IL-2, TNF-α (with RIA) and SIL-2R (with ELISA) levels were measured in 39 patients with rheumatoid arthritis. Both before and one year after treatment as well as in 35 controls. Results: Before treatment in the patients the serum IL-2 levels were significantly lower and serum SIL-2R and TNF-α levels, were significantly higher than those in the controls (P<0.01), one year after treatment, the patients without recurrence (n=31) had their serum IL-2, SIL-2R and TNF-α levels returned to normal, but in patients with recurrences (n=8) the levels were about the same as those before treatment. Conclusion: Serum IL-2, SIL-2R and TNF-α lends were closely related to the diseases process and could be of prognostic value. (authors)

  15. Using multiple biomarkers and determinants to obtain a better measurement of oxidative stress: a latent variable structural equation model approach.

    Science.gov (United States)

    Eldridge, Ronald C; Flanders, W Dana; Bostick, Roberd M; Fedirko, Veronika; Gross, Myron; Thyagarajan, Bharat; Goodman, Michael

    2017-09-01

    Since oxidative stress involves a variety of cellular changes, no single biomarker can serve as a complete measure of this complex biological process. The analytic technique of structural equation modeling (SEM) provides a possible solution to this problem by modelling a latent (unobserved) variable constructed from the covariance of multiple biomarkers. Using three pooled datasets, we modelled a latent oxidative stress variable from five biomarkers related to oxidative stress: F 2 -isoprostanes (FIP), fluorescent oxidation products, mitochondrial DNA copy number, γ-tocopherol (Gtoc) and C-reactive protein (CRP, an inflammation marker closely linked to oxidative stress). We validated the latent variable by assessing its relation to pro- and anti-oxidant exposures. FIP, Gtoc and CRP characterized the latent oxidative stress variable. Obesity, smoking, aspirin use and β-carotene were statistically significantly associated with oxidative stress in the theorized directions; the same exposures were weakly and inconsistently associated with the individual biomarkers. Our results suggest that using SEM with latent variables decreases the biomarker-specific variability, and may produce a better measure of oxidative stress than do single variables. This methodology can be applied to similar areas of research in which a single biomarker is not sufficient to fully describe a complex biological phenomenon.

  16. Mathematical Model for Localised and Surface Heat Flux of the Human Body Obtained from Measurements Performed with a Calorimetry Minisensor

    Science.gov (United States)

    Socorro, Fabiola; Rodríguez de Rivera, Pedro Jesús; Rodríguez de Rivera, Miriam

    2017-01-01

    The accuracy of the direct and local measurements of the heat power dissipated by the surface of the human body, using a calorimetry minisensor, is directly related to the calibration rigor of the sensor and the correct interpretation of the experimental results. For this, it is necessary to know the characteristics of the body’s local heat dissipation. When the sensor is placed on the surface of the human body, the body reacts until a steady state is reached. We propose a mathematical model that represents the rate of heat flow at a given location on the surface of a human body by the sum of a series of exponentials: W(t) = A0 + ∑Aiexp(−t/τi). In this way, transient and steady states of heat dissipation can be interpreted. This hypothesis has been tested by simulating the operation of the sensor. At the steady state, the power detected in the measurement area (4 cm2) varies depending on the sensor’s thermostat temperature, as well as the physical state of the subject. For instance, for a thermostat temperature of 24 °C, this power can vary between 100–250 mW in a healthy adult. In the transient state, two exponentials are sufficient to represent this dissipation, with 3 and 70 s being the mean values of its time constants. PMID:29182567

  17. Mathematical Model for Localised and Surface Heat Flux of the Human Body Obtained from Measurements Performed with a Calorimetry Minisensor.

    Science.gov (United States)

    Socorro, Fabiola; Rodríguez de Rivera, Pedro Jesús; Rodríguez de Rivera, Miriam; Rodríguez de Rivera, Manuel

    2017-11-28

    The accuracy of the direct and local measurements of the heat power dissipated by the surface of the human body, using a calorimetry minisensor, is directly related to the calibration rigor of the sensor and the correct interpretation of the experimental results. For this, it is necessary to know the characteristics of the body's local heat dissipation. When the sensor is placed on the surface of the human body, the body reacts until a steady state is reached. We propose a mathematical model that represents the rate of heat flow at a given location on the surface of a human body by the sum of a series of exponentials: W ( t ) = A ₀ + ∑A i exp( -t / τ i ). In this way, transient and steady states of heat dissipation can be interpreted. This hypothesis has been tested by simulating the operation of the sensor. At the steady state, the power detected in the measurement area (4 cm²) varies depending on the sensor's thermostat temperature, as well as the physical state of the subject. For instance, for a thermostat temperature of 24 °C, this power can vary between 100-250 mW in a healthy adult. In the transient state, two exponentials are sufficient to represent this dissipation, with 3 and 70 s being the mean values of its time constants.

  18. Measurement of magnetic susceptibility on tailings cores report on cores obtained from the Ontario Research Foundation lysimeter experiment

    International Nuclear Information System (INIS)

    1984-10-01

    Bulk susceptibility and induced magnetic remanence results are reported for 40 cores obtained from the uranium tailings lysimeter experiment at the Ontario Research Foundation. Both methods indicate a broad threefold subdivision of the tailings pile. An upper zone is characterized by an enhanced susceptibility level, which is related to enhanced concentration of both magnetite and hematite. Depletion zones, where present, are of limited areal extent and strongly developed. An intermediate zone is characterized by a mixture of large areas of reduced susceptibility that separate smaller regions of slightly enhanced susceptibility. The zones of susceptibility depletion appear to define a dendritic drainage pattern. Locally in this zone magnetite is enhanced and hematite depleted. In the lowermost zone susceptibility levels are reduced over most of the tailings bed. Only in the upper most right hand corner is there any vestige of a positive susceptibility concentration. Both magnetite and hematite are strongly depleted in this lower zone. Visually it is apparent that this lowermost depleted zone correlates to the zones of strongest 'yellowcake' development

  19. Soil water content and evaporation determined by thermal parameters obtained from ground-based and remote measurements

    Science.gov (United States)

    Reginato, R. J.; Idso, S. B.; Jackson, R. D.; Vedder, J. F.; Blanchard, M. B.; Goettelman, R.

    1976-01-01

    Soil water contents from both smooth and rough bare soil were estimated from remotely sensed surface soil and air temperatures. An inverse relationship between two thermal parameters and gravimetric soil water content was found for Avondale loam when its water content was between air-dry and field capacity. These parameters, daily maximum minus minimum surface soil temperature and daily maximum soil minus air temperature, appear to describe the relationship reasonably well. These two parameters also describe relative soil water evaporation (actual/potential). Surface soil temperatures showed good agreement among three measurement techniques: in situ thermocouples, a ground-based infrared radiation thermometer, and the thermal infrared band of an airborne multispectral scanner.

  20. Obtaining better performance in the measurement-device-independent quantum key distribution with heralded single-photon sources

    Science.gov (United States)

    Zhou, Xing-Yu; Zhang, Chun-Hui; Zhang, Chun-Mei; Wang, Qin

    2017-11-01

    Measurement-device-independent quantum key distribution (MDI-QKD) has been widely investigated due to its remarkable advantages on the achievable transmission distance and practical security. However, the relative low key generation rate limits its real-life implementations. In this work, we adopt the newly proposed four-intensity decoy-state scheme [Phys. Rev. A 93, 042324 (2016), 10.1103/PhysRevA.93.042324] to study the performance of MDI-QKD with heralded single-photon sources (HSPS). Corresponding simulation results demonstrate that the four-intensity decoy-state scheme combining HSPS can drastically improve both the key generation rate and transmission distance in MDI-QKD, which may be very promising in future MDI-QKD systems.

  1. Design and evaluation of three-level composite filters obtained by optimizing a compromise average performance measure

    Science.gov (United States)

    Hendrix, Charles D.; Vijaya Kumar, B. V. K.

    1994-06-01

    Correlation filters with three transmittance levels (+1, 0, and -1) are of interest in optical pattern recognition because they can be implemented on available spatial light modulators and because the zero level allows us to include a region of support (ROS). The ROS can provide additional control over the filter's noise tolerance and peak sharpness. A new algorithm based on optimizing a compromise average performance measure (CAPM) is proposed for designing three-level composite filters. The performance of this algorithm is compared to other three-level composite filter designs using a common image database and using figures of merit such as the Fisher ratio, error rate, and light efficiency. It is shown that the CAPM algorithm yields better results.

  2. Helium measurements of pore fluids obtained from the San Andreas Fault Observatory at Depth (SAFOD, USA) drill cores

    Science.gov (United States)

    Ali, S.; Stute, M.; Torgersen, T.; Winckler, G.; Kennedy, B. M.

    2011-02-01

    4He accumulated in fluids is a well established geochemical tracer used to study crustal fluid dynamics. Direct fluid samples are not always collectable; therefore, a method to extract rare gases from matrix fluids of whole rocks by diffusion has been adapted. Helium was measured on matrix fluids extracted from sandstones and mudstones recovered during the San Andreas Fault Observatory at Depth (SAFOD) drilling in California, USA. Samples were typically collected as subcores or from drillcore fragments. Helium concentration and isotope ratios were measured 4-6 times on each sample, and indicate a bulk 4He diffusion coefficient of 3.5 ± 1.3 × 10-8 cm2 s-1 at 21°C, compared to previously published diffusion coefficients of 1.2 × 10-18 cm2 s-1 (21°C) to 3.0 × 10-15 cm2 s-1 (150°C) in the sands and clays. Correcting the diffusion coefficient of 4Hewater for matrix porosity (˜3%) and tortuosity (˜6-13) produces effective diffusion coefficients of 1 × 10-8 cm2 s-1 (21°C) and 1 × 10-7 (120°C), effectively isolating pore fluid 4He from the 4He contained in the rock matrix. Model calculations indicate that <6% of helium initially dissolved in pore fluids was lost during the sampling process. Complete and quantitative extraction of the pore fluids provide minimum in situ porosity values for sandstones 2.8 ± 0.4% (SD, n = 4) and mudstones 3.1 ± 0.8% (SD, n = 4).

  3. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  4. Benefit of measuring basal serum calcitonin to detect medullary thyroid carcinoma in a Danish population with a high prevalence of thyroid nodules

    DEFF Research Database (Denmark)

    Hasselgren, Martin; Hegedüs, Laszlo; Godballe, Christian

    2009-01-01

    ; thyroidectomy was performed in 307 of these patients. RESULTS: Thirty-nine patients had elevated serum calcitonin; 6 of these patients had MTC detected by the initial diagnostic setup. No additional patient in the cohort was registered in the Danish Thyroid Cancer Database, reflecting that all patients with MTC......BACKGROUND: Routine measurement of serum calcitonin to detect medullary thyroid carcinoma (MTC) continues to be fiercely debated, although less attention has been paid to the positive predictive value (PPV) of this method. METHODS: We collected data from 959 patients with nontoxic nodular goiter....... The low PPV might lead to unnecessary thyroid surgery. Thus, the result of serum calcitonin measurement should always be interpreted in the context of other clinical variables. (c) 2009 Wiley Periodicals, Inc. Head Neck, 2009....

  5. The number of measurements needed to obtain high reliability for traits related to enzymatic activities and photosynthetic compounds in soybean plants infected with Phakopsora pachyrhizi

    Science.gov (United States)

    de Oliveira, Tássia Boeno; Teodoro, Paulo Eduardo; de Alvarenga, Amauri Alves; Bhering, Leonardo Lopes; Campo, Clara Beatriz Hoffmann

    2018-01-01

    Asian rust affects the physiology of soybean plants and causes losses in yield. Repeatability coefficients may help breeders to know how many measurements are needed to obtain a suitable reliability for a target trait. Therefore, the objectives of this study were to determine the repeatability coefficients of 14 traits in soybean plants inoculated with Phakopsora pachyrhizi and to establish the minimum number of measurements needed to predict the breeding value with high accuracy. Experiments were performed in a 3x2 factorial arrangement with three treatments and two inoculations in a random block design. Repeatability coefficients, coefficients of determination and number of measurements needed to obtain a certain reliability were estimated using ANOVA, principal component analysis based on the covariance matrix and the correlation matrix, structural analysis and mixed model. It was observed that the principal component analysis based on the covariance matrix out-performed other methods for almost all traits. Significant differences were observed for all traits except internal CO2 concentration for the treatment effects. For the measurement effects, all traits were significantly different. In addition, significant differences were found for all Treatment x Measurement interaction traits except coumestrol, chitinase and chlorophyll content. Six measurements were suitable to obtain a coefficient of determination higher than 0.7 for all traits based on principal component analysis. The information obtained from this research will help breeders and physiologists determine exactly how many measurements are needed to evaluate each trait in soybean plants infected by P. pachyrhizi with a desirable reliability. PMID:29438380

  6. Application value of combined measurement of serum sTn, CA242, CA19-9 and CEA in the diagnosis of gastroenterological neoplasm

    International Nuclear Information System (INIS)

    Zhang Wanzhong; Chen Zhizhou; Fan Zhenfu

    2007-01-01

    To determine the application value of four serum tumor markers sTn, CA242, CA 19-9 and CEA in the diagnosis of gastroenterological neoplasm, the serum sTn, CA242, CA19-9 and CEA in 30 normal adult controls and 60 patients with gastroenterological neoplasm were measured by IRMA. The results showed that the serum sTn, CA242, CA19-9 and CEA levels in patients with gastric carcinoma or colorectal carcinoma were much higher than those in control group (P<0.01). The serum CEA, CA19-9 and CA242 levels in patients with colorectal carcinoma were significantly higher than those in patients with gastric carcinoma (P<0.01), but the serum sTn level in the former was markedly lower (P<0.01) than that in the latter. The sensitivity of tumor marker increased with the progress of clinical stages, with a considerably higher sensitivity for stage IV compared with stage I-II (P<0.01). The combined test of four tumor markers could be more sensitive than single test in detecting gastric carcinoma and colorectal carcinoma (P<0.05). Four tumor markers are useful for diagnosing gastroenterological neoplasm, and the combined measurement of 4 tumor markers could increase the sensitivity of detecting gastric carcinoma. (authors)

  7. Performance in Measurement of Serum Cystatin C by Laboratories Participating in the College of American Pathologists 2014 CYS Survey.

    Science.gov (United States)

    Eckfeldt, John H; Karger, Amy B; Miller, W Greg; Rynders, Gregory P; Inker, Lesley A

    2015-07-01

    Cystatin C is becoming an increasingly popular biomarker for estimating glomerular filtration rate, and accurate measurements of cystatin C concentrations are necessary for accurate estimates of glomerular filtration rate. To assess the accuracy of cystatin C concentration measurements in laboratories participating in the College of American Pathologists CYS Survey. Two fresh frozen serum pools, the first from apparently healthy donors and the second from patients with chronic kidney disease, were prepared and distributed to laboratories participating in the CYS Survey along with the 2 usual processed human plasma samples. Target values were established for each pool by using 2 immunoassays and ERM DA471/IFCC international reference material. For the normal fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.960 mg/L), the all-method mean (SD, % coefficient of variation [CV]) reported by all of the 123 reporting laboratories was 0.894 mg/L (0.128 mg/L, 14.3%). For the chronic kidney disease pool (ERM-DA471/IFCC-traceable target of 2.37 mg/L), the all-method mean (SD, %CV) was 2.258 mg/L (0.288 mg/L, 12.8%). There were substantial method-specific biases (mean milligram per liter reported for the normal pool was 0.780 for Siemens, 0.870 for Gentian, 0.967 for Roche, 1.061 for Diazyme, and 0.970 for other/not specified reagents; and mean milligram per liter reported for the chronic kidney disease pool was 2.052 for Siemens, 2.312 for Gentian, 2.247 for Roche, 2.909 for Diazyme, and 2.413 for other/not specified reagents). Manufacturers need to improve the accuracy of cystatin C measurement procedures if cystatin C is to achieve its full potential as a biomarker for estimating glomerular filtration rate.

  8. Reproducibility and interoperator reliability of obtaining images and measurements of the cervix and uterus with brachytherapy treatment applicators in situ using transabdominal ultrasound.

    Science.gov (United States)

    van Dyk, Sylvia; Garth, Margaret; Oates, Amanda; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash

    2016-01-01

    To validate interoperator reliability of brachytherapy radiation therapists (RTs) in obtaining an ultrasound image and measuring the cervix and uterine dimensions using transabdominal ultrasound. Patients who underwent MRI with applicators in situ after the first insertion were included in the study. Imaging was performed by three RTs (RT1, RT2, and RT3) with varying degrees of ultrasound experience. All RTs were required to obtain a longitudinal planning image depicting the applicator in the uterine canal and measure the cervix and uterus. The MRI scan, taken 1 hour after the ultrasound, was used as the reference standard against which all measurements were compared. Measurements were analyzed with intraclass correlation coefficient and Bland-Altman plots. All RTs were able to obtain a suitable longitudinal image for each patient in the study. Mean differences (SD) between MRI and ultrasound measurements obtained by RTs ranged from 3.5 (3.6) to 4.4 (4.23) mm and 0 (3.0) to 0.9 (2.5) mm on the anterior and posterior surface of the cervix, respectively. Intraclass correlation coefficient for absolute agreement between MRI and RTs was >0.9 for all posterior measurement points in the cervix and ranged from 0.41 to 0.92 on the anterior surface. Measurements were not statistically different between RTs at any measurement point. RTs with variable training attained high levels of interoperator reliability when using transabdominal ultrasound to obtain images and measurements of the uterus and cervix with brachytherapy applicators in situ. Access to training and use of a well-defined protocol assist in achieving these high levels of reliability. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. Temporal evolution of the EIA along 95°E as obtained from GNSS TEC measurements and SAMI3 model

    Science.gov (United States)

    Kakoti, Geetashree; Kalita, Bitap Raj; Hazarika, Rumajyoti; Bhuyan, Pradip Kumar; Sharma, Sanjay; Tiwari, Ramesh Chandra

    2018-06-01

    The total electron content (TEC) derived from GNSS measurements at a trans-hemispheric meridional chain of ground stations around 95°E longitude are used to study the quiet time inter-hemispheric structure and dynamics of the equatorial ionization anomaly (EIA) during the period March 2015 to February 2016. The stations are Dibrugarh (27.5°N, 95°E, 43° dip), Kohima (25.6°N, 94.1°E, 39° dip), Aizawl (23.7°N, 92.8°E, 36° dip), Port Blair (11.63°N, 92.71°E, 9° dip) and Cocos Islands (12.2°S, 96.8°E, 43° dip). The observation shows that the northern crest of the EIA lies in the south of 23°N (Aizawl) in all seasons but recedes further south towards the equator during December solstice. The largest poleward expansion of the northern (southern) EIA is observed in the March equinox (December solstice). The equinoctial and hemispherical asymmetry of TEC is noted. The winter anomaly is observed in the northern hemisphere but not in the southern hemisphere. The highest midday TEC over any station is observed in the March equinox. The TEC in southern summer (December solstice) is significantly higher than that in the northern summer (June solstice). The observed northern EIA contracts equatorward in the postsunset period of solstice but the southern EIA persists late into the midnight in the December solstice. The asymmetry may be attributed to the different geographic location of the magnetically conjugate stations. The SAMI3 simulations broadly capture the EIA structure and the inter-hemispheric asymmetry during solstices. The difference between observations and the SAMI3 is higher in March equinox and December solstice. The higher E × B vertical drift in the 90-100°E sector and the large geographic-geomagnetic offset in observing stations may have contributed to the observed differences.

  10. Factors associated with the impossibility to obtain reliable liver stiffness measurements by means of Acoustic Radiation Force Impulse (ARFI) elastography—Analysis of a cohort of 1031 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Bota, Simona, E-mail: bota_simona1982@yahoo.com; Sporea, Ioan, E-mail: isporea@umft.ro; Sirli, Roxana, E-mail: roxanasirli@gmail.com; Popescu, Alina, E-mail: alinamircea.popescu@gmail.com; Danila, Mirela, E-mail: mireladanila@gmail.com; Jurchis, Ana, E-mail: ana.jurchis@yahoo.com; Gradinaru-Tascau, Oana, E-mail: bluonmyown@yahoo.com

    2014-02-15

    Introduction: Acoustic Radiation Force Impulse (ARFI) elastography is a non-invasive technique for liver fibrosis assessment. Aim: To assess the feasibility of ARFI elastography in a large cohort of subjects and to identify factors associated with impossibility to obtain reliable liver stiffness (LS) measurements by means of this technique. Methods: Our retrospective study included 1031 adult subjects with or without chronic liver disease. In each subject LS was assessed by means of ARFI elastography. Failure of ARFI measurements was defined if no valid measurement was obtained after at least 10 shots and unreliable in the following situations: fewer than 10 valid shots; or median value of 10 valid measurements with a success rate (SR) < 60% and/or an interquartile range interval (IQR) ≥ 30%. Results: Failure of LS measurements by means of ARFI was observed in 4 subjects (0.3%), unreliable measurements in 66 subjects (6.4%), so reliable measurements were obtained in 961 subjects (93.3%). In univariant analysis, the following risk factors were associated with failed and unreliable measurements: age over 58 years (OR = 0.49; 95% CI 0.30–0.80, p = 0.005), male gender (OR = 0.58; 95% CI 0.34–0.94, p = 0.04), BMI > 27.7 kg/m{sup 2} (OR = 0.23, 95% CI 0.13–0.41, p < 0.0001). In multivariate analysis all the factors mentioned above were independently associated with the risk of failed and unreliable measurements. Conclusions: Reliable LS measurements by means of ARFI elastography were obtained in 93.3% of cases. Older age, higher BMI and male gender were associated with the risk of failed and unreliable measurements, but their influence is limited as compared with Transient Elastography.

  11. Self-Assembled Fluorescent Bovine Serum Albumin Nanoprobes for Ratiometric pH Measurement inside Living Cells.

    Science.gov (United States)

    Yang, Qiaoyu; Ye, Zhongju; Zhong, Meile; Chen, Bo; Chen, Jian; Zeng, Rongjin; Wei, Lin; Li, Hung-wing; Xiao, Lehui

    2016-04-20

    In this work, we demonstrated a new ratiometric method for the quantitative analysis of pH inside living cells. The structure of the nanosensor comprises a biofriendly fluorescent bovine serum albumin (BSA) matrix, acting as a pH probe, and pH-insensitive reference dye Alexa 594 enabling ratiometric quantitative pH measurement. The fluorescent BSA matrix was synthesized by cross-linking of the denatured BSA proteins in ethanol with glutaraldehyde. The size of the as-synthesized BSA nanoparticles can be readily manipulated from 30 to 90 nm, which exhibit decent fluorescence at the peak wavelength of 535 nm with a pH response range of 6-8. The potential of this pH sensor for intracellular pH monitoring was demonstrated inside living HeLa cells, whereby a significant change in fluorescence ratio was observed when the pH of the cell was switched from normal to acidic with anticancer drug treatment. The fast response of the nanosensor makes it a very powerful tool in monitoring the processes occurring within the cytosol.

  12. Measurement of serum melatonin in intensive care unit patients: changes in traumatic brain injury, trauma and medical conditions

    Directory of Open Access Journals (Sweden)

    Marc A Seifman

    2014-11-01

    Full Text Available Melatonin is an endogenous hormone mainly produced by the pineal gland whose dysfunction leads to abnormal sleeping patterns. Changes in melatonin have been reported in acute traumatic brain injury (TBI, however the impact of environmental conditions typical of the intensive care unit (ICU has not been assessed. The aim of this study was to compare daily melatonin production in three patient populations treated at the ICU to differentiate the role of TBI versus ICU conditions. Forty-five patients were recruited and divided into severe TBI, trauma without TBI, medical conditions without trauma and compared to healthy volunteers. Serum melatonin levels were measured at four daily intervals at 0400h, 1000h, 1600h and 2200h for 7 days post-ICU admission by commercial ELISA. The geometric mean concentrations (95% confidence intervals of melatonin in these groups showed no difference being 8.3 (6.3-11.0, 9.3 (7.0-12.3 and 8.9 (6.6-11.9 pg/mL, respectively in TBI, trauma and intensive care cohorts. All of these patient groups demonstrated decreased melatonin concentrations when compared to control patients.This study suggests that TBI as well as ICU conditions, may have a role in the dysfunction of melatonin. Monitoring and possibly substituting melatonin acutely in these settings may assist in ameliorating longterm sleep dysfunction in all of these groups, and possibly contribute to reducing secondary brain injury in severe TBI.

  13. Technical note: Validation of a handheld meter for measuring β-hydroxybutyrate concentrations in plasma and serum from dairy cows.

    Science.gov (United States)

    Pineda, A; Cardoso, F C

    2015-12-01

    The use of handheld meters for cow-side tests for β-hydroxybutyrate (BHB) concentrations in whole blood has become common. The aim of this study was to compare serum BHB (sBHB) and plasma BHB (pBHB) concentrations analyzed using either a "gold standard" enzymatic laboratory method (LM; Randox Laboratories Ltd., Antrim, UK; cat. no. RB1007) or a handheld meter (PX; Precision Xtra, Abbott Diabetes Care Inc., Alameda, CA). Results from 374 (187 serum and 187 plasma) samples taken from Holstein cows from 11 d before (52 samples) to 5 d after parturition (137 samples) were used for the analysis. Statistical analysis was performed using the MIXED, REG, and LOGISTIC procedures of SAS (v9.4; SAS Institute Inc., Cary, NC). A linear mixed model with repeated measures was fitted for LM and PX. Regression and correlation analyses were completed to estimate the relationship and agreement between the 2 methods. Lin's concordance correlation coefficient (CCC) and Bland-Altman plots were used to evaluate agreement between LM and PX. Cross-validation by randomly splitting the data in model-building and validation sets was performed to estimate and validate the equation that predicted the LM results using PX. Receiver operating characteristic (ROC) curves were used to estimate the sensitivity (Se) and specificity (Sp) of PX at different threshold levels. The CCC was 0.74 for pBHB and 0.68 for sBHB. The 95% confidence interval of agreement of the Bland-Altman plot encompassed 96% of the difference between LM and PX for pBHB and 95% for sBHB. The mean difference for pBHB was -0.50±0.25mmol, and that for sBHB was -0.63±0.41mmol. The highest Se and Sp for PX were achieved when the threshold for ketosis was set to 1.8mmol/L for pBHB and 2.1mmol/L for sBHB. The area under the ROC curve was 0.97 for pBHB and 0.96 for sBHB. The negative bias shown by the Bland-Altman plots suggested that PX yielded higher pBHB and sBHB concentrations than the LM. However, the excellent test

  14. Serum 14-3-3η is a novel marker that complements current serological measurements to enhance detection of patients with rheumatoid arthritis

    NARCIS (Netherlands)

    Maksymowych, Walter P.; Naides, Stanley J.; Bykerk, Vivian; Siminovitch, Katherine A.; van Schaardenburg, Dirkjan; Boers, Maarten; Landewé, Robert; van der Heijde, Désirée; Tak, Paul-P.; Genovese, Mark C.; Weinblatt, Michael E.; Keystone, Edward C.; Zhukov, Olga S.; Abolhosn, Rania W.; Popov, Joanna M.; Britsemmer, Karin; van Kuijk, Arno W.; Marotta, Anthony

    2014-01-01

    Serum 14-3-3η is a novel joint-derived proinflammatory mediator implicated in the pathogenesis of rheumatoid arthritis (RA). In our study, we assessed the diagnostic utility of 14-3-3η and its association with standard clinical and serological measures. A quantitative ELISA was used to assess

  15. Test-Retest Reliability of Measurements of Hand-Grip Strength Obtained by Dynamometry from Older Adults: A Systematic Review of Research in the PubMed Database.

    Science.gov (United States)

    Bohannon, R W

    2017-01-01

    A systematic review was performed to summarize literature describing the test-retest reliability of grip strength measures obtained from older adults. Relevant literature was identified via a PubMed search. Seventeen articles were deemed appropriate based on inclusion and exclusion criteria. The relative test-retest reliability of grip strength measures obtained by dynamometry was good to excellent (intra-class correlation coefficients > 0.80) in all but 3 studies, which involved older adults with severe dementia. Absolute reliability, as indicated by summary statistics such as the minimum detectable change (95%), was more variable. As a percentage, that change ranged from 14.5% to 98.5%. Consequently, clinicians can be confident in the relative reliability of grip strength measures obtained from at risk older adults. However, relatively large percentage changes in grip strength may be necessary to conclude with confidence that a real change has occurred over time in some populations.

  16. Establishing a Method for Measuring Serum Methylmalonic Acid and Application to Women with a History of Breast Cancer

    National Research Council Canada - National Science Library

    Hauge, Ileana

    2002-01-01

    Serum concentrations of methylmalonic acid (MMA), a dicarboxylic acid and intermediate in the conversion of propionic acid to succinic acid, are elevated if there is deficiency of cobalamin (vitamin B12...

  17. Clinical significance of measurement of serum NO/NOS and TNF-α levels after treatment in patients with schizophrenia

    International Nuclear Information System (INIS)

    Nan Deqi; Du Liang; Yang Sixue; Qin Yong

    2007-01-01

    Objective: To explore the significance of changes of serum NO/NOS and TNF-α levels in patients with schizophrenia. Methods: Serum TNF-α (with R/A) and NO/NOS (with bio-chemistry) levels were determined in 41 patients with schizophrenia both before and after treatment as well as in 35 controls. Results:Before treatment the serum NOS, TNF-α levels in the patients were significantly higher than those in controls (P <0.01 ). After six weeks treatment, the levels in patients, though dropped markedly, remained significantly higher (P<0.05). Conclusion: Serum NO/NOS and TNF-α levels were closely related to the diseases process of schizophrenia and were of prognostic values. (authors)

  18. Significance of measurement of serum fibrosis markers (HA, LN, P III P, IV C) in patients with pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Zhou Mingxian

    2006-01-01

    Objective: To study the clinical significance of determination of serum fibrosis markers in patients with pulmonary tuberculosis. Methods: Serum hyaluronic acid (HA), laminin (LN), procollagen III peptide (P III P) and Type IV collagen (IV C) contents were determined with RIA in 128 patients with pulmonary tuberculosis both before and after treatment as well as in 40 controls. Results: Before treatment, the serum contents of the four markers in the patients were significantly higher than those in the controls (P 0.05). Decreases of the levels in treatment failures were not significant and the levels remained significantly higher than those in controls (P<0.01 or P<0.05). Conclusion: Determination of serum fibrosis markers levels in patients with pulmonary tuberculosis is valuable for early diagnosis as well as for evaluation of the effect of chemotherapy. (authors)

  19. Stability of serum ferritin measured by immunoturbidimetric assay after storage at -80°C for several years.

    Directory of Open Access Journals (Sweden)

    Anne-Sylvia Sacri

    Full Text Available Iron deficiency (ID may impair long-term neurological development when it occurs in young infants. In cohort studies, it is sometimes necessary to evaluate ID with sera kept frozen for several years. To assess ID, learned societies recommend measuring serum ferritin (SF level combined with C-reactive protein level. The long-term stability of C-reactive protein in frozen samples is well established but not ferritin.We measured SF level (immunoturbidimetric assay; in micrograms per liter immediately after collection from 53 young adults recruited and followed-up in Porto, Portugal, from 2011 to 2013 (SF1, and then, in 2016 in two aliquots kept frozen at- 80°C for 3 to 5 years: one without (SF2A and one with (SF2B intermediate thawing in 2014. We compared SF1 to SF2A then SF2B; statistical agreement was evaluated by the Bland and Altman method and the effect of intermediate thawing by regression modelling.Mean SF2A-SF1 and SF2B-SF1 differences were -2.1 (SD 7.0 and 48.9 (SD 66.9. Values for Bland and Altman 95% limits of agreement were higher for the comparison of SF2B and SF1 than SF2A and SF1: -82.2 to 179.9 and -15.8 to 11.8, respectively; the effect of thawing was highly significant (p <0.001.Agreement between SF values before and after 3 to 5 years of constant freezing at -80°C was in a generally accepted range, which supports the hypothesis of ferritin's stability at this temperature for a long period. In long-term storage by freezing, intermediate thawing induced a major increase in values.

  20. Measurements of serum non-ceruloplasmin copper by a direct fluorescent method specific to Cu(II).

    Science.gov (United States)

    Squitti, Rosanna; Siotto, Mariacristina; Cassetta, Emanuele; El Idrissi, Imane Ghafir; Colabufo, Nicola A

    2017-08-28

    Meta-analyses indicated the breakdown of copper homeostasis in the sporadic form of Alzheimer's disease (AD), comprising copper decreases within the brain and copper increases in the blood and the pool not bound to ceruloplasmin (non-Cp Cu, also known in the literature as "free" copper). The calculated non-Cp Cu (Walshe's) index has many limitations. A direct fluorescent method for non-Cp Cu detection has been developed and data are presented herein. The study included samples from 147 healthy subjects, 36 stable mild cognitive impairment (MCI) and 89 AD patients, who were tested for non-Cp Cu through the direct method, total serum copper, ceruloplasmin concentration and o-dianisidine ceruloplasmin activity. The indirect non-Cp Cu Walshe's index was also calculated. The direct method was linear (0.9-5.9 μM), precise (within-laboratory coefficient variation of 9.7% for low and 7.1% for high measurements), and had a good recovery. A reference interval (0-1.9 μM) was determined parametrically in 147 healthy controls (27-84 years old). The variation of non-Cp Cu was evaluated according to age and sex. Non-Cp Cu was 1.5 times higher in AD patients (regarding the upper value of the reference interval) than in healthy controls. Healthy, MCI and AD subjects were differentiated through the direct non-Cp Cu method [areas under the curve (AUC)=0.755]. Considering a 95% specificity and a 1.91 μmol/L cut-off, the sensitivity was 48.3% (confidence interval 95%: 38%-58%). The likelihood ratio (LR) was 9.94 for positive test results (LR+) and 0.54 for negative test result (LR-). The direct fluorescent test reliably and accurately measures non-Cp Cu, thereby determining the probability of having AD.

  1. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  2. Clinical significance of measurement of serum NO, IL-6 and IL-8 levels after treatment in patients with schizophrenia

    International Nuclear Information System (INIS)

    Gao Wanqin

    2010-01-01

    Objective: To study the significance of changes of serum NO, IL-6 and IL-8 levels after treatment in patients with schizophrenia. Methods: Serum IL-6, IL-8 (with RIA) and NO (with bio-chemistry) levels were determined in 37 patients with schizophrenia both before and after treatment as well as in 35 controls. Results: Before treatment, the serum IL-6, IL-8 levels in the patients were significantly higher than those in controls (P<0.01). While the serum NO levels were significantly lower (P<0.01). After six weeks' treatment, the levels of IL-6, IL-8 in the patients, though dropped markedly still remained significantly higher (P<0.05) than those in controls. The serum NO levels, though markedly increased after treatment, were still remained significantly lower than those in the controls (P<0.05). Conclusion: Serum NO, IL-6 and IL-8 levels were closely related to the diseases process of schizophrenia and were of prognostic values. (authors)

  3. Serum 25-Hydroxyvitamin D Concentrations and Indicators of Mental Health: An Analysis of the Canadian Health Measures Survey.

    Science.gov (United States)

    Chu, Filmer; Ohinmaa, Arto; Klarenbach, Scott; Wong, Zing-Wae; Veugelers, Paul

    2017-10-13

    The main function of vitamin D is calcium homeostasis. However, emerging evidence has correlated adequate serum 25-hydroxyvitamin D (25(OH)D) concentrations with better mental health. The objective of this study is to investigate the association of serum 25(OH)D concentrations with indicators of mental health such as depression, anxiety, and stress. Associations of serum 25(OH)D concentrations with four indicators of mental health were examined using ordered logistic regression models with increasing specificity that account for demographics, socio-economic status, and health. Margin effects are used to determine the probability of the average adult Canadian being in the best mental health state by groupings of serum 25(OH)D concentrations. A robust association between serum 25(OH)D concentrations and the indicators of mental health were observed. In the fully adjusted ordered logistic model, an average Canadian appeared more likely to experience better mental health when serum 25(OH)D concentrations were higher. This study adds to the weight of the existence of an association between vitamin D status and mental health, but, as this study is cross sectional, it does not establish causality. Due to the low risk of harm from toxicity and the relative modest costs of vitamin D supplements, more research to establish the effectiveness and causality of this relationship is recommended.

  4. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for the diagnosis of failure of passive transfer of immunity in foals.

    Science.gov (United States)

    Davis, Rachel; Giguère, Steeve

    2005-11-15

    To determine and compare sensitivity, specificity, accuracy, and predictive values of measurement of serum total protein concentration by refractometry as well as 5 commercially available kits for the diagnosis of failure of passive transfer (FPT) of immunity in foals. Prospective study. 65 foals with various medical problems and 35 clinically normal foals. IgG concentration in serum was assessed by use of zinc sulfate turbidity (assay C), glutaraldehyde coagulation (assay D), 2 semiquantitative immunoassays (assays F and G), and a quantitative immunoassay (assay H). Serum total protein concentration was assessed by refractometry. Radial immunodiffusion (assays A and B) was used as the reference method. For detection of IgG or = 6.0 g/dL indicated adequate IgG concentrations. Most assays were adequate as initial screening tests. However, their use as a definitive test would result in unnecessary treatment of foals with adequate IgG concentrations.

  5. Clinical significance of measurement of changes of serum TNF-α, IL-6 and IL-8 centent after treatment in patients with pregnancy induced hypertension (PIH)

    International Nuclear Information System (INIS)

    Wang Guiying

    2008-01-01

    Objective: To explore the clinical significance of changes of serum TNF-α, IL-6 and IL-8 levels in patients with pregnancy induced hypertension. Methods: Serum TNF-α, IL-6 and IL-8 levels were measured with RIA in 36 patients with pregnancy induced hypertension both before and after 2 weeks of treatment as well as in 35 controls. Results: Before treatment, the serum TNF-α, IL-6 and IL-8 levels were significantly higher in patients with PIH than those in the controls (P 0.05). Conclusion: The inflammatory cytokines such as TNF-α, IL-6 and IL-8 may play important roles in the pathogenesis of pregnancy induced hypertension. (authors)

  6. A microculture system for the measurement of antigen-induced murine lymphocyte proliferation: advantages of 5% horse serum and 5 X 10(-5) M mercaptoethanol.

    Science.gov (United States)

    Brummer, E; Vris, T W; Lawrence, H S

    1977-01-01

    Short term microculture systems which measure murine lymphocyte proliferative responses to mitogens are well established. We demonstrate here that these microculture methods are not suitable for antigen-induced responses because of the high levels of murine lymphocyte proliferation in control cultures associated with the use of fetal calf serum or human serum. We also show that this problem can be eliminated with the use of a combination of 5% horse serum and 5 X 10(-5) M mercaptoethanol. We describe an antigen-induced murine lymphocyte proliferation microculture system in which good stimulation indices are achieved and the lymphocyte proliferation in control cultures remain at a low level throughout the 7 day culture period.

  7. Clinical significance of measurement of changes in serum TNF-α and GM-CSF levels after treatment in children with bronchial asthma

    International Nuclear Information System (INIS)

    Liu Heng

    2006-01-01

    Objective: To study the clinical significance of the changes of levels of tumor necrosis factor-α (TNF-α) and granulocyte-macrophage colony stimulating factor (GM-CSF) after treatment in children with bronchial asthma. Methods: Serum TNF-α and GM-CSF levels were measured with RIA in 32 patients with bronchial asthma both before and after treatment as well as in 30 controls. Results: Before treatment the serum TNF-α and GM-CSF levels in patients were significantly higher than those in the controls (P 0.05 ). Conclusion: Changes of serum TNF-α and GM-CSF levels contents after treatment might be of prognostic importance in children with bronchial asthma. (authors)

  8. Clinical significance of measurement of changes of plasma leptin and serum NPY levels after hemodialysis in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Xia Zhengping

    2010-01-01

    Objective: To explore the clinical significance of changes of plasma leptin and serum NPY levels after hemodialysis in patients with chronic renal failure. Methods: Plasma leptin and serum NPY levels were measured with RIA both before and after hemodialysis in 31 patients with chronic renal failure as well as in 35 controls. Results: Before hemodialysis,plasma leptin and serum NPY levels were significantly higher in the patients than those in controls (P<0.01). After hemodialysis for 1 week the levels, though dropped markedly, still remained significantly higher than those in controls (P<0.05). Conclusion: The levels of leptin and NPY were significantly increased in patients with chronic renal failare. Hemodialysis could increase, the clearance rate of leptin and NPY and partially correct the levels with important clinical value. (authors)

  9. Significance of measurement of serum somatostatin (SS), growth hormone (GH), insulin-like growth factor-1 (IGF-1) and some related cytokines levels in patients with graves' disease

    International Nuclear Information System (INIS)

    Zhu Bao; Ma Yunbao; Zhang Xiaoyi

    2005-01-01

    Objective: To study the possible roles of the related hormones and cytokines in the pathogenesis of Graves' disease. Methods: Serum levels of SS, GH, IGF-1, IL-2, IL-4 and IL-6 were measured with RIA in 1) 36 patients with Graves' disease before any treatment 2) another 30 patients with Graves' disease after successful anti-thyroid drug therapy and 3) 35 controls. Results: In the untreated group, the serum levels of SS, GH, IGF-1, IL-4 and IL-6 were significantly higher but serum IL-2 levels were significantly lower than those in the controls (P<0.01). In the successfully treated group, the serum levels of SS, GH, IGF-1, IL-4 and IL-6 were significantly lower (P<0.05 or P<0.01), but serum IL-2 levels were significantly higher (P<0.01) than those in the untreated group. Conclusion: These parameters played significant roles in the pathogenesis of Graves' disease; however, the precise mechanism remained to be speculative and further studies required. (authors)

  10. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Ruiyue Yang

    Full Text Available BACKGROUND: Serum branched-chain and aromatic amino acids (BCAAs and AAAs have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. METHODS: An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. RESULTS: Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. CONCLUSION: A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  11. Clinical significance of measurements of changes of serum IL-2, SIL-2R, TNF-α levels after chemotherapy in patients with ovary cancer

    International Nuclear Information System (INIS)

    Ma Zhongwei

    2005-01-01

    Objective: To study the changes of serum IL-2, SIL-2R and TNF-α levels after chemotherapy in 34 patients with ovary cancer. Methods: Serum IL-2, TNF-α (with RIA) and SIL-2R (with ELISA) levels were measured in 34 patients with ovary cancers both before and 6 months after chemotherapy as well as in 30 controls. Results: Before chemotherapy in the patients the serum IL-2 levels were significantly lower and serum SIL-2R and TNF-α levels were significantly higher than those in the controls (P<0.01). Six months after chemotherapy, those patients without recurrence (n=21) had their IL-2, SIL-2R and TNF-α levels returned to normal, but in those with recurrences (n=10) the levels were about the same as before. Conclusion: Serum IL-2, SIL-2R and TNF-α levels changes could reflect the immunostatus of the patients as well as the progress of diseases and could be of prognostic value. (authors)

  12. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation triglycerides and total glycerides.

  13. Analytical Bias in the Measurement of Serum 25-Hydroxyvitamin D Concentrations Impairs Assessment of Vitamin D Status in Clinical and Research Settings.

    Directory of Open Access Journals (Sweden)

    Lucinda J Black

    Full Text Available Measured serum 25-hydroxyvitamin D concentrations vary depending on the type of assay used and the specific laboratory undertaking the analysis, impairing the accurate assessment of vitamin D status. We investigated differences in serum 25-hydroxyvitamin D concentrations measured at three laboratories (laboratories A and B using an assay based on liquid chromatography-tandem mass spectrometry and laboratory C using a DiaSorin Liaison assay, against a laboratory using an assay based on liquid chromatography-tandem mass spectrometry that is certified to the standard reference method developed by the National Institute of Standards and Technology and Ghent University (referred to as the 'certified laboratory'. Separate aliquots from the same original serum sample for a subset of 50 participants from the Ausimmune Study were analysed at the four laboratories. Bland-Altman plots were used to visually check agreement between each laboratory against the certified laboratory. Compared with the certified laboratory, serum 25-hydroxyvitamin D concentrations were on average 12.4 nmol/L higher at laboratory A (95% limits of agreement: -17.8,42.6; 12.8 nmol/L higher at laboratory B (95% limits of agreement: 0.8,24.8; and 10.6 nmol/L lower at laboratory C (95% limits of agreement: -48.4,27.1. The prevalence of vitamin D deficiency (defined here as 25-hydroxyvitamin D <50 nmol/L was 24%, 16%, 12% and 41% at the certified laboratory, and laboratories A, B, and C, respectively. Our results demonstrate considerable differences in the measurement of 25-hydroxyvitamin D concentrations compared with a certified laboratory, even between laboratories using assays based on liquid chromatography-tandem mass spectrometry, which is often considered the gold-standard assay. To ensure accurate and reliable measurement of serum 25-hydroxyvitamin D concentrations, all laboratories should use an accuracy-based quality assurance system and, ideally, comply with international

  14. Neuropsychological measures of attention and memory function in schizophrenia: relationships with symptom dimensions and serum monoamine activity

    Directory of Open Access Journals (Sweden)

    Henning Uwe

    2005-08-01

    Full Text Available Abstract Background Some clinical symptoms or cognitive functions have been related to the overall state of monoamine activity in patients with schizophrenia, (e.g. inverse correlation of the dopamine metabolite HVA with delusions or visual-masking performance. However, profiles (as presented here of the relations of the activity of dopamine, noradrenaline and serotonin to neuropsychologic (dysfunctions in major patient sub-groups with their very different symptomatic and cognitive characteristics have not been reported. Methods Serum measures of dopamine, noradrenaline and serotonin turnover were examined by regression analyses for the prediction of performance on 10 neuropsychological measures reflecting left- and right-hemispheric and frontal-, parietal- and temporal-lobe function in 108 patients with schizophrenia and 63 matched controls. The neuropsychological battery included tests of verbal fluency, Stroop interference, trail-making, block-design, Mooney faces recognition, picture-completion, immediate and delayed visual and verbal recall. Paranoid and nonparanoid subgroups were based on ratings from the Positive and Negative Syndrome Scale (PANSS. Groups with high and low ratings of ideas-of-reference and thought-disorder were formed from a median split on the Scale for Assessment of Positive Symptoms (SAPS. Results Verbal-fluency and Stroop-interference (left frontal and fronto-cingulate function were negatively associated with noradrenergic turnover in nonparanoid and thought-disordered patients. High dopamine turnover related to speeded trail-making (frontal modulation of set switching in those with many ideas-of-reference. In contrast, low dopamine turnover predicted poor recall in nonparanoid patients and those with little thought disorder. Serotonin metabolism did not independently contribute to the prediction any measure of cognitive performance. But, with regard to the relative activity between monoaminergic systems, increased

  15. Fluoride therapy for osteoporosis: characterization of the skeletal response by serial measurements of serum alkaline phosphatase activity.

    Science.gov (United States)

    Farley, S M; Wergedal, J E; Smith, L C; Lundy, M W; Farley, J R; Baylink, D J

    1987-03-01

    Optimum use of fluoride therapy for osteoporosis requires a sensitive and convenient index of the skeletal response to fluoride. Since previous studies had shown that serum alkaline phosphatase activity (SALP) was increased in response to fluoride therapy, we examined serial measurements of SALP in 53 osteoporotics treated with 66 to 110 mg of sodium fluoride (NaF) for 12 to 91 months. SALP was increased in 87% of the subjects during therapy with fluoride. The increase in SALP was thought to reflect the osteogenic action of fluoride based on the findings that SALP correlated with both trabecular bone area (r = .81, P less than .001) and osteoid length (r = .67, P less than .01) in iliac crest biopsies, predicted increased bone density on spinal radiographs in response to fluoride therapy with an 87% accuracy, and predicted decreased back pain in response to fluoride with a 91% accuracy. In addition, the SALP response to fluoride was seen earlier than other therapeutic responses as indicated by the findings that the tau 1/2 for the SALP response (ie, time for 1/2 of the patients to show a significant response) was significantly less (1.2 +/- 0.3 yr) than that for the pain response (1.6 +/- 0.3 yr, P less than .05) or that for the radiographic response (3.7 +/- 0.5 yr, P less than .001). Although most patients responded to fluoride with an increase in SALP, evaluation of the kinetics of the SALP response to fluoride revealed marked interpatient variation.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Validity and reproducibility of resting metabolic rate measurements in rural Bangladeshi women: comparison of measurements obtained by Medgem and by Deltatrac device

    NARCIS (Netherlands)

    Alam, D.S.; Hulshof, P.J.M.; Roordink, D.; Meltzer, M.; Yunus, M.; Salam, M.A.; Raaij, van J.M.A.

    2005-01-01

    Objective:To assess reproducibility and validity of resting metabolic rate (RMR) of Bangladeshi women as measured with the MedGem device and using the Deltatrac metabolic monitor as a reference; and (2) to evaluate the FAO/WHO/UNU basal metabolic rate (BMR)-prediction equations. Design:In each of

  17. Automated measurement of serum thyroxine with the ''AIRA II,'' as compared with competitive protein binding and radioimmunoassay

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.V.R.

    1978-01-01

    Two conventional serum thyroxine assays, run in separate laboratories, one by competitive protein binding and one by radioimmunoassay, were used to evaluate the automated ARIA II (Becton Dickinson Immunodiagnostics) serum thyroxine assay. Competitive protein binding as compared to ARIA II with 111 clinical serum samples gave a slope of 1.04 and a correlation coefficient of 0.94. The radioimmunoassay comparison to ARIA II with 53 clinical serum samples gave a slope of 1.05 and a correlation coefficient of 0.92. The ARIA II inter-assay coefficient of variation for 10 replicates of low, medium, and high thyroxine serum samples was 6.2, 6.0, and 2.9%, respectively, with an inter-assay coefficient of variation among 15 different assays of 15.5, 10.1, and 7.9%. The automated ARIA II, with a 2.2-min cycle per sample, gives results that compare well with those by manual methodology

  18. Reliability of the measures of weight-bearing distribution obtained during quiet stance by digital scales in subjects with and without hemiparesis.

    Science.gov (United States)

    de Araujo-Barbosa, Paulo Henrique Ferreira; de Menezes, Lidiane Teles; Costa, Abraão Souza; Couto Paz, Clarissa Cardoso Dos Santos; Fachin-Martins, Emerson

    2015-05-01

    Described as an alternative way of assessing weight-bearing asymmetries, the measures obtained from digital scales have been used as an index to classify weight-bearing distribution. This study aimed to describe the intra-test and the test/retest reliability of measures in subjects with and without hemiparesis during quiet stance. The percentage of body weight borne by one limb was calculated for a sample of subjects with hemiparesis and for a control group that was matched by gender and age. A two-way analysis of variance was used to verify the intra-test reliability. This analysis was calculated using the differences between the averages of the measures obtained during single, double or triple trials. The intra-class correlation coefficient (ICC) was utilized and data plotted using the Bland-Altman method. The intra-test analysis showed significant differences, only observed in the hemiparesis group, between the measures obtained by single and triple trials. Excellent and moderate ICC values (0.69-0.84) between test and retest were observed in the hemiparesis group, while for control groups ICC values (0.41-0.74) were classified as moderate, progressing from almost poor for measures obtained by a single trial to almost excellent for those obtained by triple trials. In conclusion, good reliability ranging from moderate to excellent classifications was found for participants with and without hemiparesis. Moreover, an improvement of the repeatability was observed with fewer trials for participants with hemiparesis, and with more trials for participants without hemiparesis.

  19. NMR measurement of dynamic nuclear polarization: a technique to test the quality of its volume average obtained with different NMR coil configurations

    International Nuclear Information System (INIS)

    Zhao, W.H.; Cox, S.F.J.

    1980-07-01

    In the NMR measurement of dynamic nuclear polarization, a volume average is obtained where the contribution from different parts of the sample is weighted according to the local intensity of the RF field component perpendicular to the large static field. A method of mapping this quantity is described. A small metallic object whose geometry is chosen to perturb the appropriate RF component is scanned through the region to be occupied by the sample. The response of the phase angle of the impedance of a tuned circuit comprising the NMR coil gives a direct measurement of the local weighting factor. The correlation between theory and experiment was obtained by using a circular coil. The measuring method, checked in this way, was then used to investigate the field profiles of practical coils which are required to be rectangular for a proposed experimental neutron polarizing filter. This method can be used to evaluate other practical RF coils. (author)

  20. Clinical value of combined measurement of serum alpha-fetoprotein, alpha-L-fucosidase and ferritin levels in the diagnosis of primary liver cancer

    International Nuclear Information System (INIS)

    Zhang Aimin; Chai Xiaohong; Jin Ying; Dong Xuemei

    2005-01-01

    Objective: To investigate the clinical value of combined measurement of serum alpha-fetoprotein (AFP), alpha-L-fucosidase (AFU) and ferritin (SF) levels in the diagnosis of primary liver cancer. Methods: Serum AFP, AFU (with RIA) and SF (with biochemical method) were determined in 52 patients with primary liver cancer and 40 controls. Results: The positive rates of AFP, AFU and SF in patient with liver cancer were 82.7%, 86.6% and 76.9%, respectively. Positive rates with combined measurement of AFP plus AFU, AFP plus SF, and AFP plus AFU, SF were 94.2%, 90.4% and 98.1% respectively. Conclusion: Combined measurement of AFP, AFU and SF can significantly increase the positive rate in the diagnosis of primary liver cancer. (authors)

  1. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  2. Standardization of clinical enzyme analysis using frozen human serum pools with values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures.

    Science.gov (United States)

    Tong, Qing; Chen, Baorong; Zhang, Rui; Zuo, Chang

    Variation in clinical enzyme analysis, particularly across different measuring systems and laboratories, represents a critical but long-lasting problem in diagnosis. Calibrators with traceability and commutability are imminently needed to harmonize analysis in laboratory medicine. Fresh frozen human serum pools were assigned values for alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyltransferase (GGT), creatine kinase (CK) and lactate dehydrogenase (LDH) by six laboratories with established International Federation of Clinical Chemistry and Laboratory Medicine reference measurement procedures. These serum pools were then used across 76 laboratories as a calibrator in the analysis of five enzymes. Bias and imprecision in the measurement of the five enzymes tested were significantly reduced by using the value-assigned serum in analytical systems with open and single-point calibration. The median (interquartile range) of the relative biases of ALT, AST, GGT, CK and LDH were 2.0% (0.6-3.4%), 0.8% (-0.8-2.3%), 1.0% (-0.5-2.0%), 0.2% (-0.3-1.0%) and 0.2% (-0.9-1.1%), respectively. Before calibration, the interlaboratory coefficients of variation (CVs) in the analysis of patient serum samples were 8.0-8.2%, 7.3-8.5%, 8.1-8.7%, 5.1-5.9% and 5.8-6.4% for ALT, AST, GGT, CK and LDH, respectively; after calibration, the CVs decreased to 2.7-3.3%, 3.0-3.6%, 1.6-2.1%, 1.8-1.9% and 3.3-3.5%, respectively. The results suggest that the use of fresh frozen serum pools significantly improved the comparability of test results in analytical systems with open and single-point calibration.

  3. The Comparative Study of the Measurement of Serum Cystatin C and 99mTc-DTPA for the Measurement of Glomerular Filtration Rate (GFR) in Type 2 Diabetic Nephropathy

    International Nuclear Information System (INIS)

    Kong Linghua; Wu Junyuan; Gao Bin; Wang Xueqin; Gu Kaikai

    2010-01-01

    To explore the clinical value between measurement of serum cystatin C (Cys C) and determination of plasma with 99m Tc-DTPA glomerular filtration rate (GFR) clearance for type 2 diabetes (T2DM) in early detection of renal damage, the serum cystatin C levels in 87 patients with type 2 diabetes were determined by immune turbidimetry Cys C. The patients were also carried out dynamic imaging to measure renal GFR. The result showed that the serum levels of Cys C in patients with Type 2 diabetic was 1.68 ± 0.52 mg / L, the normal group was 0.72±0.26 mg/L; The GFR in patients with T2DM was 93.8 ± 30.2 ml/min/1.73m 2 , the control group was 107.48±15.23 ml/min/1.73m 2 , there was significant difference between patients and controls (P 99m Tc-DTPA renal dynamic imaging. The serum Cys C could reflect the damage in early diabetic patients. The method is simple, accurate and easy to spread. The renal dynamic imaging method of GFR determination is slightly complex and requires specialized equipment. It can reflect the sub-renal function. The combined measurement of serum Cys C and GFR are very important in the early detection of type 2 diabetic patients with early renal function. (authors)

  4. [The influence of corneal thickness and curvature on the difference between intraocular pressure measurements obtained with a non-contact tonometer and those with a Goldmann applanation tonometer].

    Science.gov (United States)

    Matsumoto, T; Makino, H; Uozato, H; Saishin, M; Miyamoto, S

    2000-05-01

    The influence of corneal thickness and curvature on the difference between intraocular pressure (IOP) measurements obtained with a non-contact tonometer (NCT) and those with a Goldmann applanation tonometer (GAT) was studied. The corneal thickness and curvature were obtained in 230 eyes of 115 subjects. The correlation between them and ratios of measurement with NCT to that with GAT ([NCT/GAT]) were examined. [NCT/GAT] and corneal thickness showed a significant positive correlation (r = 0.556, p < 0.01), but, the correlation between [NCT/GAT] and the radius of corneal curvature was not statistically significant (r = -0.035, p = 0.30). The thick cornea has more influence on the measurement with NCT than GAT, because IOP is measured with NCT over a wider applanation area. The corneas with steeper curvature also cause higher corneal rigidity and produce more overestimation of NCT measurement, while they have stronger capillary attraction of the precorneal tear film for the GAT tip and also produce overestimation of GAT measurement. As a result, [NCT/GAT] was believed to be not influenced by the corneal curvature.

  5. The Influence of Corneal Thickness and Curvature on the Difference Between Intraocular Pressure Measurements Obtained with a Non-contact Tonometer and Those with a Goldmann Applanation Tonometer.

    Science.gov (United States)

    Matsumoto; Makino; Uozato; Saishin; Miyamoto

    2000-11-01

    Purpose: The influence of corneal thickness and curvature on the difference between intraocular pressure (IOP) measurements obtained with a non-contact tonometer (NCT) and those with a Goldmann applanation tonometer (GAT) was studied.Methods: The corneal thickness and curvature were obtained in 230 eyes of 115 subjects. The correlation between them and ratios of measurement with NCT to that with GAT ([NCT/GAT]) were examined.Results: [NCT/GAT] and corneal thickness showed a significant positive correlation (r = 0.556, P <.01), but, the correlation between [NCT/GAT] and the radius of corneal curvature was not statistically significant (r = -0.035, P =.30).Conclusion: The thick cornea has more influence on the measurement with NCT than GAT, because IOP is measured with NCT over a wider applanation area. The corneas with steeper curvature also cause higher corneal rigidity and produce more overestimation of NCT measurement, while they have stronger capillary attraction of the precorneal tear film for the GAT tip and also produce overestimation of GAT measurement. As a result, [NCT/GAT] was believed to be not influenced by the corneal curvature.

  6. Comparison of serum testosterone and estradiol measurements in 3174 European men using platform immunoassay and mass spectrometry; relevance for the diagnostics in aging men.

    Science.gov (United States)

    Huhtaniemi, Ilpo T; Tajar, Abdelouahid; Lee, David M; O'Neill, Terence W; Finn, Joseph D; Bartfai, György; Boonen, Steven; Casanueva, Felipe F; Giwercman, Aleksander; Han, Thang S; Kula, Krzysztof; Labrie, Fernand; Lean, Michael E J; Pendleton, Neil; Punab, Margus; Silman, Alan J; Vanderschueren, Dirk; Forti, Gianni; Wu, Frederick C W

    2012-06-01

    The limitations of serum testosterone and estradiol (E(2)) measurements using non-extraction platform immunoassays (IAs) are widely recognized. Switching to more specific mass spectrometry (MS)-based methods has been advocated, but directly comparative data on the two methods are scarce. We compared serum testosterone and E(2) measurements in a large sample of middle-aged/elderly men using a common platform IA and a gas chromatography (GC)-MS method, in order to assess their limitations and advantages, and to diagnose male hypogonadism. Of subjects from the European Male Aging Study (n=3174; age 40-79 years), peripheral serum testosterone and E(2) were analyzed using established commercial platform IAs (Roche Diagnostics E170) and in-house GC-MS methods. Over a broad concentration range, serum testosterone concentration measured by IA and MS showed high correlation (R=0.93, PIA/MS correlation was weaker in E(2) measurements (R=0.32, P40.8 pmol/l, and R=0.74, P40.8 pmol/l). Using MS as the comparator method, IA ascertained low testosterone compatible with hypogonadism (IA for the detection of low E(2) (40.7 pmol/l) were 13.3 and 99.3%, and for high E(2) (>120 pmol/l) 88.4 and 88.6%. A validated platform IA is sufficient to detect subnormal testosterone concentrations in the diagnosis of male hypogonadism. The IA used for E(2) measurements showed poor correlation with MS and may only be suitable for the detection of high E(2) in men.

  7. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  8. Evaluation of a fluorescence polarographic immunoassay with increased sensitivity for measurement of low concentrations of tobramycin in serum

    NARCIS (Netherlands)

    Touw, D J; de Graaf, A I; de Goede, P

    The limits of quantitation of the assay of tobramycin in serum by the fluorescence polarization immunoassay system marketed by Abbott Laboratories (TDxFLx system) are 0.1 and 10.0 mg/L. For some pharmacokinetic studies, however, a more sensitive analysis is needed. The sensitivity of the TDxFLx

  9. Comparison of Measurements of the Uterus and Cervix Obtained by Magnetic Resonance and Transabdominal Ultrasound Imaging to Identify the Brachytherapy Target in Patients With Cervix Cancer

    International Nuclear Information System (INIS)

    Dyk, Sylvia van; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash

    2014-01-01

    Purpose: To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Methods and Materials: Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. Results: A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (±SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (±3.353) mm to 3.7 (±3.856) mm, and −1.46 (±3.308) mm to 0.47 (±3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Conclusion: Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer

  10. Comparison of Measurements of the Uterus and Cervix Obtained by Magnetic Resonance and Transabdominal Ultrasound Imaging to Identify the Brachytherapy Target in Patients With Cervix Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Sylvia van, E-mail: sylvia.vandyk@petermac.org [Radiation Therapy Services, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Kondalsamy-Chennakesavan, Srinivas [Rural Clinical School, University of Queensland, Toowoomba, Queensland (Australia); Schneider, Michal [Department of Medical Imaging and Radiation Science, Monash University, Clayton, Victoria (Australia); Bernshaw, David [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Narayan, Kailash [Division of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Department of Obstetrics and Gynaecology, Melbourne University, Melbourne, Victoria (Australia)

    2014-03-15

    Purpose: To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Methods and Materials: Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. Results: A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (±SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (±3.353) mm to 3.7 (±3.856) mm, and −1.46 (±3.308) mm to 0.47 (±3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Conclusion: Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer.

  11. Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction.

    Science.gov (United States)

    Yuan, Chao; Kosewick, Justin; He, Xiang; Kozak, Marta; Wang, Sihe

    2011-05-15

    Vitamin D plays important roles in bone health and a variety of other pathophysiological conditions. 1α,25-Dihydroxyvitamin D is the active form of vitamin D. Quantification of serum 1α,25-dihydroxyvitamin D is useful for evaluation of several diseases including chronic renal failure, hypoparathyroidism, sarcoidosis, and rickets. Measurement of 1α,25-dihydroxyvitamin D is very challenging due to its low circulating concentration and presence of interfering substances in serum. In this report, a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantifying serum 1α,25-dihydroxyvitamin D is described. Lithium adducts of 1α,25-dihydroxyvitamin D were formed prior to mass spectrometry analysis to improve ionization efficiency. We tested a number of different sample preparation procedures and found that immunoaffinity extraction was the method of choice because it completely removed isobaric interferences and matrix effects present in patient serum. Extraction efficiency, expressed as absolute recovery, was greater than 60% in both patient serum and charcoal-stripped serum. This method was linear from 3.4 to 206.2 pg/mL for 1α,25-dihydroxyvitamin D(3) and 3.9 to 212.6 pg/mL for 1α,25-dihydroxyvitamin D(2) with an accuracy of 89.8-98.4% and 97.5-115.7%, respectively. Inter-assay and intra-assay coefficients of variance (CVs) for both analytes at two different concentration levels ranged from 2.5-7.0%. Comparison with a radioimmunoassay for measuring total 1α,25-dihydroxyvitamin D concentration using 40 patient samples showed a Deming regression slope of 0.751, a y-intercept of 0.84 pg/mL, an r value of 0.7909, and a mean percentage difference of -27.1%. Comparison with a reference LC/MS/MS method (n = 20) showed a Deming regression slope of 1.020, a y-intercept of 1.32 pg/mL, an r value of 0.9797, and a mean percentage difference of -2.9%. In conclusion, usage of immunoaffinity extraction enabled a sensitive LC/MS/MS method for

  12. Significance of the measurement of serum transforming growth factor-α ad laminin in patients with three kinds of gastrointestinal malignant tumors

    International Nuclear Information System (INIS)

    Li Qing; Ma Yunbao

    2001-01-01

    The authors study the relationship between the levels of serum TGF-α and LN in gastrointestinal malignant tumor and the tumor formation and metastasis. Adopting radioimmunoassay measured serum TGF-α and LN levels in 40 cases of carcinoma of stomach, 24 cases of carcinoma of esophagus and 32 cases of liver cancer. The level of serum TGF-α in the patients with the three kinds of tumors was significantly higher than that of the normal control group (P < 0.05, P < 0.01); except for the group of carcinoma of esophagus, the level of LN was significantly higher than that of the normal control group (P < 0.05, P < 0.01). Meanwhile, the two markers of the metastasis group were significantly higher than that of the group without metastasis (P < 0.05). Elevation of the level of serum TGF-α and LN is closely related to the invasion and metastasis of the three kinds of malignant tumors, and is valuable for tumor diagnosis and prognosis evaluation

  13. Diagnostic value of serial measurement of C-reactive protein in serum and matrix metalloproteinase-9 in drainage fluid in the detection of infectious complications and anastomotic leakage in patients with colorectal resection.

    Science.gov (United States)

    Kostić, Zoran; Panišić, Marina; Milev, Boško; Mijušković, Zoran; Slavković, Damjan; Ignjatović, Mile

    2015-10-01

    Postoperative infectious complications are one of the most important problems in surgical treatment of colorectal cancer (CRC), being present in up to 40% of patients. The aim of this paper was to establish the significance of serial measurement of C-reactive protein (CRP) in serum and matrix metalloproteinase-9 (MMP-9) in drainage fluid for the detection of infectious complications and anastomotic leakage (AL) in patients with colorectal resection. CRP and MMP-9 values in serum and drainage fluid, respectively, were measured on the first, third, fifth, and seventh postoperative day (POD) in 150 patients with colorectal resection and primary anastomosis. The values obtained were compared between the patients without complicatons and those with surgical site and remote infections and AL. Surgical site infections (SSIs) were observed in 41 (27.3%), and remote infections in 10 (6.7%) patients. Clinically evident AL was observed in 15 (10/6) patients. In 82% of the patients with SSIs, serum CRP value on POD 5 exceeded 82 mg/L, with 81% specificity. AL was reported in 85% and 92% of the patients on PODs 5 and 7, respectively, with CRP values of 77 mg/L and 90 mg/L, respectively. The specificity was 77% for POD 5 and 88% for POD 7. All the patients with CRP values exceeding 139 mg/L on POD 5 had some of SSIs and/or AL. The mean values of MMP-9 were not statistically different between the group without complications (n = 99) and the group with AL (n = 15). Serial measurement of CRP is recommended for screening of infectious complications of colorectal resection. Patients with CRP values above 139 mg/L on POD 5 cannot be discharged from hospital, and require an intensive search for infectious complications, particularly AL. MMP-9 measurement in drainage fluid is not relevant in the detection of AL in patients with colorectal resection.

  14. First In-Core Simultaneous Measurements of Nuclear Heating and Thermal Neutron Flux Obtained With the Innovative Mobile Calorimeter CALMOS Inside the OSIRIS Reactor

    Science.gov (United States)

    Carcreff, Hubert; Salmon, Laurent; Bubendorff, Jacques; Lepeltier, Valérie

    2016-10-01

    Nuclear heating inside a MTR reactor has to be known in order to design and run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. Calorimeter working modes, measurement procedures, main modeling and experimental results and expected advantages of this new technique have been already presented in previous papers. However, these first in-core measurements were not performed beyond 6 W · g-1, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 1014 n · cm-2 · s-1 and nuclear heating up to 12 W · g-1. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a comparison is made between results obtained by the probe calibration coefficient and the zero methods. Thermal neutron flux evaluation from SPND signal processing required a specific TRIPOLI-4 Monte Carlo calculation which has been performed with the precise CALMOS cell geometry. In addition, the Finite Element model for temperatures map prediction inside the calorimetric cell has been upgraded with recent experimental data obtained up to 12 W · g-1. Finally, the experience feedback led us to improvement perspectives. A second device is

  15. Serum urate gene associations with incident gout, measured in the Framingham Heart Study, are modified by renal disease and not by body mass index.

    Science.gov (United States)

    Reynolds, Richard J; Vazquez, Ana I; Srinivasasainagendra, Vinodh; Klimentidis, Yann C; Bridges, S Louis; Allison, David B; Singh, Jasvinder A

    2016-02-01

    We hypothesized that serum urate-associated SNPs, individually or collectively, interact with BMI and renal disease to contribute to risk of incident gout. We measured the incidence of gout and associated comorbidities using the original and offspring cohorts of the Framingham Heart Study. We used direct and imputed genotypes for eight validated serum urate loci. We fit binomial regression models of gout incidence as a function of the covariates, age, type 2 diabetes, sex, and all main and interaction effects of the eight serum urate SNPs with BMI and renal disease. Models were also fit with a genetic risk score for serum urate levels which corresponds to the sum of risk alleles at the eight SNPs. Model covariates, age (P = 5.95E-06), sex (P = 2.46E-39), diabetes (P = 2.34E-07), BMI (P = 1.14E-11) and the SNPs, rs1967017 (P = 9.54E-03), rs13129697 (P = 4.34E-07), rs2199936 (P = 7.28E-03) and rs675209 (P = 4.84E-02) were all associated with incident gout. No BMI by SNP or BMI by serum urate genetic risk score interactions were statistically significant, but renal disease by rs1106766 was statistically significant (P = 6.12E-03). We demonstrated that minor alleles of rs1106766 (intergenic, INHBC) were negatively associated with the risk of incident gout in subjects without renal disease, but not for individuals with renal disease. These analyses demonstrate that a significant component of the risk of gout may involve complex interplay between genes and environment.

  16. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  17. Metabolic Rather Than Body Composition Measurements Are Associated With Lower Serum Natriuretic Peptide Concentrations in Normal Weight and Obese Men

    DEFF Research Database (Denmark)

    Asferg, Camilla L; Nielsen, Søren J; Andersen, Ulrik B

    2014-01-01

    BACKGROUND: Several studies have shown that obese persons have lower circulating natriuretic peptide (NP) concentrations. The cause of the relative NP deficiency seen in obese persons is poorly understood, although variation in body composition and metabolic abnormalities has been suggested to play...... a role. Thus, the aim of this study was to assess whether variation in circulating NP concentrations would be associated with differences in metabolic disturbances rather than with differences in body composition. METHODS: In 27 normal weight men (body mass index (BMI) = 20.0-24.9kg/m(2)) and 103 obese...... weight ± SD was 74.9±6.7kg in the normal weight men and 106.1±10.8kg in obese men. Applying multiple regressions, adjusting for age and weight status (normal weight vs. obese), serum MR-proANP concentrations were significantly inversely associated with serum insulin concentrations (β = -0.39; P

  18. Correlations among the Main Body Measurements in Pikeperch Larvae from 10 to 25 Days Post-Hatch, Obtained Out-Of-Season

    Directory of Open Access Journals (Sweden)

    Adrian Grozea

    2010-10-01

    Full Text Available The pikeperch (Sander lucioperca is one of the most valuable carnivorous fish species in Europe, and in Romania as well. In the literature there are no relevant data on growth dynamic and correlation among the main body measurements in pikeperch larvae obtained out-of-season and reared in recirculated aquaculture system (RAS. The aim of this study was to bring information for clarifying some of these aspects. Our results emphasized that correlation coefficient between maximum body high (H and total length (TL together with standard length (SL decrease linear from 10 to 25 DPH. The correlation coefficients between the main length measurements (TL and SL reveal a very high correlation between the two traits in pikeperch larvae. High correlations between body weight (BW and the other length measurements were observed.

  19. Liquid chromatography-tandem mass spectrometry method for the measurement of serum mevalonic acid: a novel marker of hydroxymethylglutaryl coenzyme A reductase inhibition by statins.

    Science.gov (United States)

    Waldron, Jenna; Webster, Craig

    2011-05-01

    Mevalonic acid (MVA) is synthesized at an early and rate-limiting step in the biosynthesis of cholesterol by the enzyme hydroxymethylglutaryl coenzyme A (HMG-CoA) reductase, and is a useful measure of statin efficacy or treatment. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of serum MVA has been developed. Following the in vitro conversion of MVA to mevalonic acid lactone (MVAL) in the serum, MVAL and a deuterated internal standard were extracted using an online solid-phase extraction procedure. Chromatographic separation was achieved using a Luna PFP column (Phenomenex), with enhanced selectivity and improved resolution for polar compounds. A gradient system was used, with mobile phase comprising methanol and water (5 mmol/L ammonium formate buffer, pH 2.5). Analysis was performed using an API 5000 tandem mass spectrometer (Applied Biosystems) in positive electrospray ionization mode. The method showed excellent recoveries (98 ± 8%) and imprecision (intra-assay coefficient of variation of 2.2% [6.5 ng/mL] and 2.6% [10.5 ng/mL], and inter-assay coefficient of variation of 9% [10.5 ng/mL]). The assay provides a calibration range up to 50 ng/mL with a limit of detection at 0.1 ng/mL. A simple, rapid and analytically specific method has been developed for the measurement of serum MVA, in the form of MVAL. The high analytical sensitivity of the method allows for accurate quantitation of MVAL in serum samples, both at the endogenous levels found in healthy individuals and in statin-treated patients where normal levels are expected to be greatly reduced through the inhibition of HMG-CoA reductase.

  20. Serum Creatinine: Not So Simple!

    OpenAIRE

    DELANAYE, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDM...

  1. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  2. Acute effects of propylthiouracil (PTU) on thyroidal iodide organification and peripheral iodothyronine deiodination: correlation with serum PTU levels measured by radioimmunoassay

    International Nuclear Information System (INIS)

    Cooper, D.S.; Saxe, V.C.; Meskell, M.; Maloof, F.; Ridgway, E.C.

    1981-01-01

    Propylthiouracil (PTU) levels in serum have been measured by RIA in five normal volunteers and four patients with untreated Graves's disease. Peak PTU levels after 50, 200, and 300 mg PTU were 0.91 +/- 0.13, 2.9 +/- 0.6, and 4.0 +/- 0.6 μg/ml in the normal subjects and 1.04 +/- 0.1, 4.5 +/- 0.7, and 7.1 +/- 0.4 μg/ml in the hyperthyroid patients, respectively. Peak PTU levels and PTU area under the curve were significantly greater at the 300-mg dose (P 123 I. Four hours after an oral dose of PTU, the hyperthyroid patients had a greater percentage of perchlorate-dischargeable 123 I than the euthyroid controls (+38 +/- 5% vs. 13 +/- 2%; P 3 and rT 3 were measured serially over 24 h after single oral doses of 50, 200, and 300 mg PTU. In normal volunteers, serum T 3 declined slightly but significantly after the 200- and 300-mg doses; an increase in rT 3 was also noted, but the changes did not attain statistical significance. In the hyperthyroid patients, serum T 3 fell from 501 +/- 29 to 379 +/- 27 ng/dl after 50 mg PTU (P 3 rose after each dose: from 119 +/- 12 to 131 +/- 11 ng/dl (P = NS) after 50 mg PTU, from 113 +/- 11 to 146 +/- 12 ng/dl (P < 0.02) after 200 mg PTU,

  3. The bottomside parameters B0, B1 obtained from incoherent scatter measurements during a solar maximum and their comparisons with the IRI-2001 model

    Directory of Open Access Journals (Sweden)

    N. K. Sethi

    2002-06-01

    Full Text Available High resolution electron density profiles (Ne measured with the Arecibo (18.4 N, 66.7 W, Incoherent Scatter radar (I. S. are used to obtain the bottomside shape parameters B0, B1 for a solar maximum period (1989–90. Median values of these parameters are compared with those obtained from the IRI-2001 model. It is observed that during summer, the IRI values agree fairly well with the Arecibo values, though the numbers are somewhat larger during the daytime. Discrepancies occur during winter and equinox, when the IRI underestimates B0 for the local times from about 12:00 LT to about 20:00 LT. Furthermore, the IRI model tends to generally overestimate B1 at all local times. At Arecibo, B0 increases by about 50%, and B1 decreases by about 30% from solar minimum to solar maximum.Key words. Ionosphere (equational ionosphere; modeling and forecasting

  4. Clinical significance of measurement of serum IL-8, TNF-α and gastrin contents in helicobacter pylori associated digestive tract diseases

    International Nuclear Information System (INIS)

    Cao Jianfan; Ma Yunbao; Gao Leihua

    2003-01-01

    Objective: To investigate the relationship between the serum levels of IL-8, TNF-α, Gastrin and disease process in HP infection associated chronic gastritis and duodenal ulcer. Methods: Diagnosis was established in 35 HP positive chronic gastritis and 30 HP positive duodenal ulcer patients through gastroscopy, histopathology and 14 C-UBT test. RIA was adopted to measure the plasma contents of the three parameters in those 65 patients and 32 controls. Results: The serum IL-8, TNF-α and Gastrin (Gas) levels in patients with chronic gastritis were significantly higher than those in controls (p<0.01). Significant difference also existed between the contents in the two disease group (p<0.01). Conclusion: It proved that HP infection played an important role in the development of the two digestive tract diseases

  5. Conditions to obtain precise and true measurements of the intramolecular {sup 13}C distribution in organic molecules by isotopic {sup 13}C nuclear magnetic resonance spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bayle, Kevin [EBSI Team, Interdisciplinary Chemistry: Synthesis, Analysis, Modelling (CEISAM), University of Nantes-CNRS UMR 6230, 2 Rue de la Houssinière, BP 92208, F-44322, Nantes Cedex 3 (France); Gilbert, Alexis [Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Earth–Life Science Institute, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Julien, Maxime [EBSI Team, Interdisciplinary Chemistry: Synthesis, Analysis, Modelling (CEISAM), University of Nantes-CNRS UMR 6230, 2 Rue de la Houssinière, BP 92208, F-44322, Nantes Cedex 3 (France); Yamada, Keita [Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Silvestre, Virginie; Robins, Richard J.; Akoka, Serge [EBSI Team, Interdisciplinary Chemistry: Synthesis, Analysis, Modelling (CEISAM), University of Nantes-CNRS UMR 6230, 2 Rue de la Houssinière, BP 92208, F-44322, Nantes Cedex 3 (France); Yoshida, Naohiro [Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Earth–Life Science Institute, Tokyo Institute of Technology, Meguro, Tokyo 152-8551 (Japan); Remaud, Gérald S., E-mail: gerald.remaud@univ-nantes.fr [EBSI Team, Interdisciplinary Chemistry: Synthesis, Analysis, Modelling (CEISAM), University of Nantes-CNRS UMR 6230, 2 Rue de la Houssinière, BP 92208, F-44322, Nantes Cedex 3 (France)

    2014-10-10

    Highlights: • Evaluation of the trueness and precision criteria of isotopic {sup 13}C NMR spectrometry. • Use of bi-labelled [1,2-{sup 13}C{sub 2}]acetic acid to determine the performance of the instrumental response. • Inter-calibration of the {sup 13}C intramolecular composition of acetic acid using the technique GC-Py–irm-MS. - Abstract: Intramolecular {sup 13}C composition gives access to new information on the (bio) synthetic history of a given molecule. Isotopic {sup 13}C NMR spectrometry provides a general tool for measuring the position-specific {sup 13}C content. As an emerging technique, some aspects of its performance are not yet fully delineated. This paper reports on (i) the conditions required to obtain satisfactory trueness and precision for the determination of the internal {sup 13}C distribution, and (ii) an approach to determining the “absolute” position-specific {sup 13}C content. In relation to (i), a precision of <1% can be obtained whatever the molecule on any spectrometer, once quantitative conditions are met, in particular appropriate proton decoupling efficiency. This performance is a prerequisite to the measurement of isotope fractionation either on the transformed or residual compound when a chemical reaction or process is being studied. The study of the trueness has revealed that the response of the spectrometer depends on the {sup 13}C frequency range of the studied molecule, i.e. the chemical shift range. The “absolute value” and, therefore, the trueness of the {sup 13}C NMR measurements has been assessed on acetic acid and by comparison to the results obtained on the fragments from COOH and CH{sub 3} by isotopic mass spectrometry coupled to a pyrolysis device (GC-Py–irm-MS), this technique being the reference method for acetic acid. Of the two NMR spectrometers used in this work, one gave values that corresponded to those obtained by GC-Py–irm-MS (thus, the “true” value) while the other showed a bias, which was

  6. Long-term study of the impact of methotrexate on serum cytokines and lymphocyte subsets in patients with active rheumatoid arthritis: correlation with pharmacokinetic measures

    Science.gov (United States)

    Kremer, Joel M; Lawrence, David A; Hamilton, Robert; McInnes, Iain B

    2016-01-01

    Objective To describe changes in immune parameters observed during long-term methotrexate (MTX) therapy in patients with active rheumatoid arthritis (RA) and explore correlations with simultaneously measured MTX pharmacokinetic (PKC) parameters. Design Prospective, open-label, long-term mechanism of action study. Setting University clinic. Methods MTX was initiated at a single weekly oral dose of 7.5 mg and dose adjusted for efficacy and toxicity for the duration of the study. Standard measures of disease activity were performed at baseline and every 6–36 months. Serum cytokine measurements in blood together with lymphocyte surface immunophenotypes and stimulated peripheral blood mononuclear cell (PBMC) cytokine production were assessed at each clinical evaluation. Results Cytokine concentrations exhibited multiple significant correlations with disease activity measures over time. The strongest correlations observed were for interleukin (IL)-6 (r=0.45, p<0.0001 for swollen joints and r=0.32, p=0.002 for tender joints) and IL-8 (r=0.25, p=0.01 for swollen joints). Significant decreases from baseline were observed in serum IL-1B, IL-6 and IL-8 concentrations. The most significant changes were observed for IL-6 (p<0.001). Significant increases from baseline were observed in IL-2 release from PBMCs ex vivo (p<0.01). In parallel, multiple statistically significant correlations were observed between MTX PKC measures and immune parameters. The change in swollen joint count correlated inversely with the change in area under the curve (AUC) for MTX (r=−0.63, p=0.007). Conclusions MTX therapy of patients with RA is accompanied by a variety of changes in serum cytokine expression, which in turn correlate strongly with clinical disease activity and MTX pharmacokinetics (PKCs). These data strongly support the notion that MTX mediates profound and functionally relevant effects on the immunological hierarchy in the RA lesion. PMID:27335660

  7. Comparison of ATLAS Tilecal MODULE No 8 high-precision metrology measurement results obtained by laser (JINR) and photogrammetric (CERN) methods

    CERN Document Server

    Batusov, V; Gayde, J C; Khubua, J I; Lasseur, C; Lyablin, M V; Miralles-Verge, L; Nessi, Marzio; Rusakovitch, N A; Sissakian, A N; Topilin, N D

    2002-01-01

    The high-precision assembly of large experimental set-ups is of a principal necessity for the successful execution of the forthcoming LHC research programme in the TeV-beams. The creation of an adequate survey and control metrology method is an essential part of the detector construction scenario. This work contains the dimension measurement data for ATLAS hadron calorimeter MODULE No. 8 (6 m, 22 tons) which were obtained by laser and by photogrammetry methods. The comparative data analysis demonstrates the measurements agreement within +or-70 mu m. It means, these two clearly independent methods can be combined and lead to the rise of a new-generation engineering culture: high-precision metrology when precision assembling of large scale massive objects. (3 refs).

  8. Comparison of ATLAS tilecal module No. 8 high-precision metrology measurement results obtained by laser (JINR) and photogrammetric (CERN) methods

    International Nuclear Information System (INIS)

    Batusov, V.; Budagov, Yu.; Gayde, J.C.

    2002-01-01

    The high-precision assembly of large experimental set-ups is of a principal necessity for the successful execution of the forthcoming LHC research programme in the TeV-beams. The creation of an adequate survey and control metrology method is an essential part of the detector construction scenario. This work contains the dimension measurement data for ATLAS hadron calorimeter MODULE No. 8 (6 m, 22 tons) which were obtained by laser and by photogrammetry methods. The comparative data analysis demonstrates the measurements agreement within ± 70 μm. It means, these two clearly independent methods can be combined and lead to the rise of a new-generation engineering culture: high-precision metrology when precision assembling of large scale massive objects

  9. Comparison Between Stress Obtained by Numerical Analysis and In-Situ Measurements on a Flexible Pipe Subjected to In-Plane Bending Test

    DEFF Research Database (Denmark)

    Vestergaard Lukassen, Troels; Glejbøl, Kristian; Lyckegaard, Anders

    2016-01-01

    to stress patterns obtained during in-situ OMS measurements carried out during an actual experimental inplane bending test. The study showed a good correlation between the stress variation predicted with the finite element model and the measured stress variation.......To predict the lifetime and long-term properties of tensile armour wires in a dynamically loaded pipe, it is essential to have a tool which allows detailed prediction of the stress variations in the tensile armour wires during global pipe loading. Furthermore, detailed understanding of the stress...... variations will allow for performance optimization of the armour layers. To study the detailed stress variations in flexible pipes during dynamic loading, a comprehensive three-dimensional implicit nonlinear finite element model has been developed. The predicted numerical stress variations will be compared...

  10. Adalimumab for Treatment of Noninfectious Uveitis: Immunogenicity and Clinical Relevance of Measuring Serum Drug Levels and Antidrug Antibodies.

    Science.gov (United States)

    Cordero-Coma, Miguel; Calleja-Antolín, Sara; Garzo-García, Irene; Nuñez-Garnés, Ana M; Álvarez-Castro, Carolina; Franco-Benito, Manuel; Ruiz de Morales, Jose G

    2016-12-01

    To evaluate the rate of immunogenicity induced by adalimumab and its relationship with drug serum levels and clinical responses in patients with noninfectious uveitis. Prospective observational study. Consecutive patients from 1 referral center who initiated treatment with adalimumab for active noninfectious uveitis resistant to conventional therapy. All patients received 40 mg adalimumab every other week. Patients were evaluated clinically and immunologically before and after 4, 8, and 24 weeks of treatment. Clinical evaluation included assessment of changes in visual acuity, degree of inflammation in the anterior chamber and vitreous cavity, central macular thickness, and retinal angiographic leakage. Immunologic evaluation included assessment of serum trough adalimumab and antibodies against adalimumab (AAA) levels and class II HLA typing. Twenty-five patients were enrolled. Overall, 18 of 25 patients (72%) showed a favorable clinical response to adalimumab therapy. Eleven patients (44%) achieved a complete response and 7 (28%) achieved a partial response. However, 7 of 25 patients (28%) were considered nonresponders. Median trough adalimumab serum levels were higher in responders than in nonresponders (P uveitis outcome was observed only in patients with permanent AAA+, which correlated with undetectable adalimumab trough levels (P = 0.014). Treatment of noninfectious uveitis with adalimumab is associated with high rates of favorable clinical response. Overall, adalimumab trough levels were higher in responder patients. Development of permanent AAA was associated with undetectable trough adalimumab levels and worse uveitis outcome. Immunogenicity was more common in patients in whom uveitis was associated with a systemic disease and was not influenced by concomitant immunosuppressors. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. Cost-effectiveness of routine measuring of serum drug concentrations and anti-drug antibodies in treatment of rheumatoid arthritis patients with TNF-α blockers

    Directory of Open Access Journals (Sweden)

    Laine J

    2016-04-01

    Full Text Available Juha Laine,1 T Sakari Jokiranta,2,3 Kari K Eklund,4,5 Merja Väkeväinen,1 Kari Puolakka6 1Pfizer Oy, Helsinki, 2United Medix Laboratories Ltd, Espoo, 3Research Programs Unit, Immunobiology, 4Department of Rheumatology, University of Helsinki, 5Helsinki University Central Hospital, Helsinki, 6Department of Medicine, South Karelia, Finland Abstract: Monitoring of anti-drug antibodies (ADAbs or serum concentrations of biologicals in treatment of rheumatoid arthritis could provide an explanation for a loss of efficacy and help in the choice of subsequent medication. Current clinical practices do not generally include such monitoring of tumor necrosis factor (TNF-α blockers on a routine basis. The main aims of this study were to estimate the probabilities of optimal and nonoptimal treatment decisions if infliximab or adalimumab drug trough level (DL and ADAbs are tested or not in rheumatoid arthritis, and to model cost-effectiveness of performing such monitoring on a routine basis. Data on DLs and ADAbs concentrations were obtained in Finland from clinically requested monitoring analyses of 486 and 1,137 samples from patients on adalimumab and infliximab, respectively. DL was within the target range in 42% of samples from adalimumab- and 50.4% of infliximab-treated patients. ADAbs were detected in approximately 20% and 13.5% of samples from adalimumab- and infliximab-treated patients, respectively. ADAbs were found in 52.3% and 41.3% of those with low adalimumab or infliximab DLs, respectively. The monitoring data were incorporated into probabilities for making the optimal treatment decision. Economic impact of clinical decision-making was modeled in a short-term (3–6 months scenario with 100 hypothetical patients. In the model, the combined measurement of DLs and ADAbs was cost-saving compared to the nontesting scenario when the monitoring results affected the treatment decision in at least 2–5 of 100 patients, a proportion which is easily

  12. Effects of nonlinear error correction of measurements obtained by peak flowmeter using the Wright scale to assess asthma attack severity in children

    Directory of Open Access Journals (Sweden)

    Stamatović Dragana

    2007-01-01

    Full Text Available Introduction: Monitoring of peak expiratory flow (PEF is recommended in numerous guidelines for management of asthma. Improvements in calibration methods have demonstrated the inaccuracy of original Wright scale of peak flowmeter. A new standard, EN 13826 that was applied to peak flowmeter was adopted on 1st September 2004 by some European countries. Correction of PEF readings obtained with old type devices for measurement is possible by Dr M. Miller’s original predictive equation. Objective. Assessment of PEF correction effect on the interpretation of measurement results and management decisions. Method. In children with intermittent (35 or stable persistent asthma (75 aged 6-16 years, there were performed 8393 measurements of PEF by Vitalograph normal-range peak flowmeter with traditional Wright scale. Readings were expressed as percentage of individual best values (PB before and after correction. The effect of correction was analyzed based on The British Thoracic Society guidelines for asthma attack treatment. Results. In general, correction reduced the values of PEF (p<0.01. The highest mean percentage error (20.70% in the measured values was found in the subgroup in which PB ranged between 250 and 350 l/min. Nevertheless, the interpretation of PEF after the correction in this subgroup changed in only 2.41% of measurements. The lowest mean percentage error (15.72%, and, at the same time, the highest effect of correction on measurement results interpretation (in 22.65% readings were in children with PB above 450 l/min. In 73 (66.37% subjects, the correction changed the clinical interpretation of some values of PEF after correction. In 13 (11.8% patients, some corrected values indicated the absence or a milder degree of airflow obstruction. In 27 (24.54% children, more than 10%, and in 12 (10.93%, more than 20% of the corrected readings indicated a severe degree of asthma exacerbation that needed more aggressive treatment. Conclusion

  13. Reproducibility of the measurement of central corneal thickness in healthy subjects obtained with the optical low coherence reflectometry pachymeter and comparison with the ultrasonic pachymetry.

    Science.gov (United States)

    Garza-Leon, Manuel; Plancarte-Lozano, Eduardo; Valle-Penella, Agustín Del; Guzmán-Martínez, María de Lourdes; Villarreal-González, Andrés

    2018-01-01

    Corneal pachymetry is widely used for refractive surgery and follow up in keratoconus, accurate measurement is essential for a safe surgery. To assess intraobserver reliability of central corneal thickness (CCT) measurements using optical low-coherence reflectometry (OLCR) technology and its agreement with ultrasonic pachymeter (US). Randomized and prospective comparative evaluation of diagnostic technology. One randomly healthy eye of subjects was scanned three times with both devices. Intraobserver within-subject standard deviation (Sw), coefficient of variation (CVw) and intraclass correlation coefficient (ICC) were obtained for reliability analysis; for study agreement, data were analyzed using the paired-sample t test and the Bland-Altman LoA method. The mean of three scans of each equipment was used to assess the LoA. The study enrolled 30 eyes of 30 subjects with average age of 28.70 ± 8.06 years. For repeatability, the Sw were 3.41 and 5.96 µ, the intraobserver CVw was 2 and 4% and ICC 0.991 and 0.988, for OLCR and US respectively. The mean CCT difference between OLCR and US was 8.90 ± 9.03 µ (95% confidence interval: 5.52-2.27 µ), and the LoA was 35.40 µ. OLCR technology provided reliable intraobserver CCT measurements. Both pachymetry measurements may be used interchangeably with minimum calibration adjustment. Copyright: © 2018 Permanyer.

  14. Serum sickness

    Science.gov (United States)

    ... the problem should be stopped. Avoid using that medicine or antiserum in the future. ... Call your provider if you received medicine or antiserum in the last 4 weeks and have symptoms of serum sickness.

  15. Single measurement of serum 25(OH)D: is classification into month-specific cutpoints useful in accounting for seasonal variation?

    Science.gov (United States)

    Saliba, W; Barnett-Griness, O; Rennert, G

    2012-09-01

    Classification into month-specific cutpoints is used to minimize misclassification associated with single measurement of serum 25(OH)D. This study aims to evaluate this strategy, and to compare it with the widely used classification into overall cutpoints. For this purpose, we studied 69,553 subjects in whom serum 25(OH)D was tested on two different occasions. The level of agreement between the quartiles of the first and second tests was 43.8% between the month-specific quartiles and 43.1% between the overall quartiles. The level of agreement between the quartiles of the two approaches was 80.0% and 94.3% in the first and second test, respectively. The extent of seasonal variation (summer-autumn as compared with winter-spring) of serum 25(OH)D was higher in males and in Jews, inversely associated with baseline levels, body mass index and age, and directly associated with socioeconomic class. The month-specific cutpoint strategy does not seem to offer advantage over the overall cutpoints strategy.

  16. First in-core simultaneous measurements of nuclear heating and thermal neutron flux obtained with the innovative mobile calorimeter CALMOS inside the OSIRIS reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lepeltier, Valerie; Bubendorff, Jacques; Carcreff, Hubert [Nuclear studies and reactor irradiation Service, CEA Saclay 91191 Gif sur Yvette (France); Salmon, Laurent [Thermalhydraulics and Fluid Mechanics Section, CEA Saclay 91191 Gif sur Yvette, (France)

    2015-07-01

    Nuclear heating inside a MTR reactor has to be known in order to design and to run irradiation experiments which have to fulfill target temperature constraints. This measurement is usually carried out by calorimetry. The innovative calorimetric system, CALMOS, has been studied and built in 2011 for the 70 MWth OSIRIS reactor operated by CEA. Thanks to a new type of calorimetric probe, associated to a specific displacement system, it provides measurements along the fissile height and above the core. This development required preliminary modelling and irradiation of mock-ups of the calorimetric probe in the ex-core area, where nuclear heating rate does not exceed 2 W.g{sup -1}. The calorimeter working modes, the different measurement procedures allowed with such a new probe, the main modeling and experimental results and expected advantages of this new technique have been already presented. However, these first in-core measurements were not performed beyond 6 W.g{sup -1}, due to an inside temperature limitation imposed by a safety authority requirement. In this paper, we present the first in-core simultaneous measurements of nuclear heating and conventional thermal neutron flux obtained by the CALMOS device at the 70 MW nominal reactor power. For the first time, this experimental system was operated in nominal in-core conditions, with nominal neutron flux up to 2.7 10{sup 14} n.cm{sup -2}.s{sup -1} and nuclear heating up to 12 W.g{sup -1}. A comprehensive measurement campaign carried out from 2013 to 2015 inside all accessible irradiation locations of the core, allowed to qualify definitively this new device, not only in terms of measurement ability but also in terms of reliability. After a brief reminder of the calorimetric cell configuration and displacement system specificities, first nuclear heating distributions at nominal power are presented and discussed. In order to reinforce the heating evaluation, a systematic comparison is made between results obtained by

  17. The role of serial measurements of serum insulin-like growth factor 1 levels in the development of retinopathy of prematurity.

    Science.gov (United States)

    Dorum, Bayram Ali; Yılmaz, Cansu Canbolat; Köksal, Nilgün; Özkan, Hilal; Yıldız, Meral; Özmen, Ahmet Tuncer

    2017-03-01

    To determine the role of serum insulin-like growth factor-1 levels in the development of retinopathy of prematurity, which is a major cause of childhood blindness worldwide. We prospectively studied newborn infants born at a postmenstrual age of prematurity screening and follow-up. Retinopathy of prematurity was classified according to the international classification of retinopathy of prematurity. Serum Insulin like growth factor 1 levels were measured serially in blood samples on the 1 st , 3 rd , 7 th , 21 st , and 28 th day. Among the 40 infants, 11 (27.5%) constituted the retinopathy of prematurity group and 29 comprised the non-retinopathy of prematurity group. In the retinopathy of prematurity group, the mean gestational age and birth weight was significantly lower. The demographic features of the study cohort were similar. The duration of mechanical ventilation was significantly greater in the retinopathy of prematurity group compared with the non-retinopathy of prematurity group (p=0.036). In terms of neonatal morbidities such as respiratory distress syndrome, intraventricular hemorrhage, bronchopulmonary dysplasia, patent ductus arteriosus, and necrotizing enterocolitis, no differences were detected between the groups. The mean serum insulin-like growth factor-1 levels in retinopathy of prematurity group were significantly lower than those in the non-retinopathy of prematurity group at each time point (1 st , 3 rd , 7 th , 21 st , and 28 th day of postnatal life) (p=0.001). This study demonstrated the low serum insulin-like growth factor-1 levels was associated with retinopathy of prematurity development.

  18. Serial measurements of serum PDGF-AA, PDGF-BB, FGF2, and VEGF in multiresistant ovarian cancer patients treated with bevacizumab

    Directory of Open Access Journals (Sweden)

    Madsen Christine

    2012-09-01

    Full Text Available Abstract Introduction Anti-VEGF treatment has proven effective in recurrent ovarian cancer. However, the identification of the patients most likely to respond is still pending. It is well known that the angiogenesis is regulated by several other pro-angiogenic proteins, e.g. the platelet - derived growth factor (PDGF system and the fibroblast growth factor (FGF system. These other signaling pathways may remain active or become upregulated during anti-VEGF treatment. The aim of the present study was to investigate if potential changes of PDGF-BB, PDGF-AA, and FGF2 before and during bevacizumab treatment had predictive value for early progression or survival. Furthermore, we wanted to investigate the importance of serum VEGF in the same cohort. Methods This study included 106 patients with chemotherapy-resistant epithelial ovarian cancer who were treated with single agent bevacizumab as part of a biomarker protocol. Patients were evaluated for response by the Response Evaluation Criteria In Solid Tumors (RECIST and/ or Gynecologic Cancer Intergroup (GCIG CA125 criteria. Serum samples were collected at baseline and prior to each treatment. FGF2, PDGF-BB, PDGF-AA were quantified simultaneously using the Luminex system, and VEGF-A was measured by ELISA. Eighty-eight baseline samples were avaliable for FGF2, PDGF-BB, PDGF-AA analysis, and 93 baseline samples for VEGF. Results High baseline serum VEGF was related to poor overall survival. Furthermore, high serum PDGF-BB and FGF2 was of prognostic significance. None of the markers showed predictive value, neither at baseline level nor during the treatment.

  19. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Science.gov (United States)

    Atherton, Rachel R; Williams, Jane E; Wells, Jonathan C K; Fewtrell, Mary S

    2013-01-01

    Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C) model; (2) To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy), BMI and skinfold thicknesses (SFT); and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2)/Z)) in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients). DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement) FM SDS 0.03 (± 0.62); FFM SDS -0.04 (± 0.72)), and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2). BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  20. Use of fat mass and fat free mass standard deviation scores obtained using simple measurement methods in healthy children and patients: comparison with the reference 4-component model.

    Directory of Open Access Journals (Sweden)

    Rachel R Atherton

    Full Text Available BACKGROUND: Clinical application of body composition (BC measurements for individual children has been limited by lack of appropriate reference data. OBJECTIVES: (1 To compare fat mass (FM and fat free mass (FFM standard deviation scores (SDS generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtained using the reference 4-component (4-C model; (2 To determine the extent to which scores from simple methods agree with those from the 4-C model in identification of abnormal body composition. DESIGN: FM SDS were calculated for 4-C model, dual-energy X-ray absorptiometry (DXA; GE Lunar Prodigy, BMI and skinfold thicknesses (SFT; and FFM SDS for 4CM, DXA and bioelectrical impedance analysis (BIA; height(2/Z in 927 subjects aged 3.8-22.0 y (211 healthy, 716 patients. RESULTS: DXA was the most accurate method for both FM and FFM SDS in healthy subjects and patients (mean bias (limits of agreement FM SDS 0.03 (± 0.62; FFM SDS -0.04 (± 0.72, and provided best agreement with the 4-C model in identifying abnormal BC (SDS ≤-2 or ≥ 2. BMI and SFTs were reasonable predictors of abnormal FM SDS, but poor in providing an absolute value. BIA was comparable to DXA for FFM SDS and in identifying abnormal subjects. CONCLUSIONS: DXA may be used both for research and clinically to determine FM and FFM SDS. BIA may be used to assess FFM SDS in place of DXA. BMI and SFTs can be used to measure adiposity for groups but not individuals. The performance of simpler techniques in monitoring longitudinal BC changes requires investigation. Ultimately, the most appropriate method should be determined by its predictive value for clinical outcome.

  1. Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL

    Directory of Open Access Journals (Sweden)

    Gurmukh Singh

    2015-04-01

    Full Text Available Objective: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. Methods: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a evidence of corrective action in patients with serum folate values 25.7 ng/mL. Results: The prevalence of serum folate levels, in patients, 25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate 60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL. Keywords: Serum folate, Prevalence of folate deficiency, Neural tube defects, Optimum serum folate level, Utility of folate testing

  2. Routing of Fatty Acids from Fresh Grass to Milk Restricts the Validation of Feeding Information Obtained by Measuring (13)C in Milk.

    Science.gov (United States)

    Auerswald, Karl; Schäufele, Rudi; Bellof, Gerhard

    2015-12-09

    Dairy production systems vary widely in their feeding and livestock-keeping regimens. Both are well-known to affect milk quality and consumer perceptions. Stable isotope analysis has been suggested as an easy-to-apply tool to validate a claimed feeding regimen. Although it is unambiguous that feeding influences the carbon isotope composition (δ(13)C) in milk, it is not clear whether a reported feeding regimen can be verified by measuring δ(13)C in milk without sampling and analyzing the feed. We obtained 671 milk samples from 40 farms distributed over Central Europe to measure δ(13)C and fatty acid composition. Feeding protocols by the farmers in combination with a model based on δ(13)C feed values from the literature were used to predict δ(13)C in feed and subsequently in milk. The model considered dietary contributions of C3 and C4 plants, contribution of concentrates, altitude, seasonal variation in (12/13)CO2, Suess's effect, and diet-milk discrimination. Predicted and measured δ(13)C in milk correlated closely (r(2) = 0.93). Analyzing milk for δ(13)C allowed validation of a reported C4 component with an error of information. However, the error was not random but varied seasonally and correlated with the seasonal variation in long-chain fatty acids. This indicated a bypass of long-chain fatty acids from fresh grass to milk.

  3. Development of a generalized correlation for phase-velocity measurements obtained from impedance-probe pairs in two-phase flow systems

    International Nuclear Information System (INIS)

    Hsu, C.T.; Keshock, E.G.; McGill, R.N.

    1983-01-01

    A flag type electrical impedance probe has been developed at the Oak Ridge National Lab (ORNL) to measure liquid- and vapor-phase velocities in steam-water mixtures flowing through rod bundles. Measurements are made by utilizing the probes in pairs, installed in line, parallel to the flow direction, and extending out into the flow channel. The present study addresses performance difficulties by examining from a fundamental point of view the two-phase flow system which the impedance probes typically operate in. Specifically, the governing equations (continuity, momentum, energy) were formulated for both air-water and steam-water systems, and then subjected to a scaling analysis. The scaling analysis yielded the appropriate dimensionless parameters of significance in both kinds of systems. Additionally, with the aid of experimental data obtained at ORNL, those parameters of significant magnitude were established. As a result, a generalized correlation was developed for liquid and vapor phase velocities that makes it possible to employ the impedance probe velocity measurement technique in a wide variety of test configurations and fluid combinations

  4. Measurement of cetuximab and panitumumab-unbound serum EGFR extracellular domain using an assay based on slow off-rate modified aptamer (SOMAmer reagents.

    Directory of Open Access Journals (Sweden)

    Noh Jin Park

    Full Text Available Response to cetuximab (Erbitux® and panitumumab (Vectibix® varies among individuals, and even those who show response ultimately gain drug resistance. One possible etiologic factor is differential interaction between the drug and target. We describe the development of an assay based on Slow Off-rate Modified Aptamer (SOMAmer(™ reagents that can distinguish drug-bound from unbound epidermal growth factor receptor (EGFR.This quantitative assay uses a SOMAmer reagent specific for EGFR extracellular domain (ECD as a capturing reagent. Captured SOMAmer is quantitated using PCR. Linearity and accuracy (recovery of the assay were assessed using normal sera and purified EGFR ECD.This EGFR ECD assay showed linearity between 2.5 and 600 ng/mL. Average recovery was 101%. The assay detected EGFR but showed little cross-reactivity to other ErbB proteins: 0.4% for ErbB2, 6.9% for ErbB3, and 1.3% for ErbB4. Preincubation of normal serum with either cetuximab or panitumumab resulted in a dose-dependent decrease in EGFR ECD levels measured using the SOMAmer assay; preincubation did not affect measurement with an ELISA.This SOMAmer-based serum EGFR ECD assay accurately and specifically measures EGFR in serum. Detection of significant amounts of drug-unbound EGFR in patients undergoing cetuximab or panitumumab treatment could be an indicator of poor drug response. Further studies are needed to evaluate the utility of the assay as an indicator of drug efficacy or as a guide to dosing.

  5. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  6. Correlation between Serum Levels of 3,3',5'-Triiodothyronine and Thyroid Hormones Measured by Liquid Chromatography-Tandem Mass Spectrometry and Immunoassay.

    Science.gov (United States)

    Sakai, Hiroyuki; Nagao, Hidenori; Sakurai, Mamoru; Okumura, Takako; Nagai, Yoshiyuki; Shikuma, Junpei; Ito, Rokuro; Imazu, Tetsuya; Miwa, Takashi; Odawara, Masato

    2015-01-01

    For measuring serum 3,3',5'-triiodothyronine (rT3) levels, radioimmunoassay (RIA) has traditionally been used owing to the lack of other reliable methods; however, it has recently become difficult to perform. Meanwhile, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has recently been attracting attention as a novel alternative method in clinical chemistry. To the best of our knowledge, there are no studies to date comparing results of the quantification of human serum rT3 between LC-MS/MS and RIA. We therefore examined the feasibility of LC-MS/MS as a novel alternative method for measuring serum rT3, thyroxine (T4), and 3,5,3'-triiodothyronine (T3) levels. Assay validation was performed by LC-MS/MS using quality control samples of rT3, T4, and T3 at 4 various concentrations which were prepared from reference compounds. Serum samples of 50 outpatients in our department were quantified both by LC-MS/MS and conventional immunoassay for rT3, T4, and T3. Correlation coefficients between the 2 measurement methods were statistically analyzed respectively. Matrix effects were not observed with our method. Intra-day and inter-day precisions were less than 10.8% and 9.6% for each analyte at each quality control level, respectively. Intra-day and inter-day accuracies were between 96.2% and 110%, and between 98.3% and 108.6%, respectively. The lower limit of quantification was 0.05 ng/mL. Strong correlations were observed between the 2 measurement methods (correlation coefficient, T4: 0.976, p < 0.001; T3: 0.912, p < 0.001; rT3: 0.928, p < 0.001). Our LC-MS/MS system requires no manual cleanup operation, and the process after application of a sample is fully automated; furthermore, it was found to be highly sensitive, and superior in both precision and accuracy. The correlation between the 2 methods over a wide range of concentrations was strong. LC-MS/MS is therefore expected to become a useful tool for clinical diagnosis and research.

  7. Correlation between Serum Levels of 3,3',5'-Triiodothyronine and Thyroid Hormones Measured by Liquid Chromatography-Tandem Mass Spectrometry and Immunoassay.

    Directory of Open Access Journals (Sweden)

    Hiroyuki Sakai

    Full Text Available For measuring serum 3,3',5'-triiodothyronine (rT3 levels, radioimmunoassay (RIA has traditionally been used owing to the lack of other reliable methods; however, it has recently become difficult to perform. Meanwhile, liquid chromatography-tandem mass spectrometry (LC-MS/MS has recently been attracting attention as a novel alternative method in clinical chemistry. To the best of our knowledge, there are no studies to date comparing results of the quantification of human serum rT3 between LC-MS/MS and RIA. We therefore examined the feasibility of LC-MS/MS as a novel alternative method for measuring serum rT3, thyroxine (T4, and 3,5,3'-triiodothyronine (T3 levels.Assay validation was performed by LC-MS/MS using quality control samples of rT3, T4, and T3 at 4 various concentrations which were prepared from reference compounds. Serum samples of 50 outpatients in our department were quantified both by LC-MS/MS and conventional immunoassay for rT3, T4, and T3. Correlation coefficients between the 2 measurement methods were statistically analyzed respectively.Matrix effects were not observed with our method. Intra-day and inter-day precisions were less than 10.8% and 9.6% for each analyte at each quality control level, respectively. Intra-day and inter-day accuracies were between 96.2% and 110%, and between 98.3% and 108.6%, respectively. The lower limit of quantification was 0.05 ng/mL. Strong correlations were observed between the 2 measurement methods (correlation coefficient, T4: 0.976, p < 0.001; T3: 0.912, p < 0.001; rT3: 0.928, p < 0.001.Our LC-MS/MS system requires no manual cleanup operation, and the process after application of a sample is fully automated; furthermore, it was found to be highly sensitive, and superior in both precision and accuracy. The correlation between the 2 methods over a wide range of concentrations was strong. LC-MS/MS is therefore expected to become a useful tool for clinical diagnosis and research.

  8. Validation of calculated tissue maximum ratio obtained from measured percentage depth dose (PPD) data for high energy photon beam ( 6 MV and 15 MV)

    International Nuclear Information System (INIS)

    Osei, J.E.

    2014-07-01

    dose (dmax) were 1.5 cm for both PDD and TMR at 6 MV and 2.5 cm and 2.6 cm for PDD and TMR at 15 MV respectively. The minimum relative percentage differences recorded were 1.6 % for 40x40 cm field size and 1.2 % for 5x5 cm field size at 6 MV and 15 MV respectively, while the maximum relative percentage differences recorded were 2.0 % for 10x10 cm field size and 1.4 % for 40x40 cm at 6 MV and 15 MV x-ray beam respectively. The relative differences between the calculated and the measured TMRs increases with depth at all field sizes. It can be concluded that, although based on the results the general agreement between the calculated and measured TMRs is good but for clinically high energy photon beam, it is required that TMR should be measured directly especially when treating deep internal tumor. However it is recommended that comparison of the measured TMR and PDD with that obtained during commission, should be included in the annual quality assurance (QAs) of the machine at SGMC. (au)

  9. Accuracy of serum markers, progesterone and vitamins measurements for early screening of abortions in the eastern region of Algeria (Batna

    Directory of Open Access Journals (Sweden)

    Sara Mouffouk

    2018-02-01

    Full Text Available Spontaneous abortion is an involuntary interruption of pregnancy before 22 weeks of gestation. According to the Algerian National Institute of Public Health the percentage of women suffering from permanent complications during pregnancy is approximately 15%. The aim of this study is the determination of some biochemical analytes, including folic acid, vitamin B12, alphafoetoproteine, beta human chorionic gonadotropin (β-hCG, progesterone and oestradiol (uE3, which are involved in the detection of pregnancy failures. This case-control study was carried out on women in the process of abortion and a control group with viable pregnancies in the East region of Algeria (Batna during the year 2015. In the present investigation, 69 pregnant women during the first and second trimester were recruited during the first and second trimesters as cases (with miscarriages and the control group (n=69 was constituted of women who had normal ultrasound. The average concentration of alpha-fetoprotein is significantly low during the first trimester, but it is very high during the second trimester between cases and controls. The median values of β- hCG, uE3 and progesterone decrease very significantly. The mean concentration of serum folate and vitamin B12 did not change significantly between cases and controls in the first and second trimesters. The results of this study revealed that, spontaneous abortions are associated with changes in serum markers and progesterone, which could form an important part in the early diagnosis of non-viable pregnancies. However, vitamins levels have no significant effects on these pregnancies.

  10. A coupled-enzyme equilibrium method for measuring urea in serum: optimization and evaluation of the AACC study group on urea candidate reference method.

    Science.gov (United States)

    Sampson, E J; Baird, M A; Burtis, C A; Smith, E M; Witte, D L; Bayse, D D

    1980-06-01

    We describe a coupled-enzyme equilibrium method for measuring urea in serum, which is performed on supernates prepared by treating each specimen with Ba(OH)2 and ZnSO4 (Somogyi reagent). Analytical recovery of [14C]urea added to a variety of matrices was essentially complete (mean, 100.6%) for the supernates after precipitation. Nine variables were univariately examined in arriving at the reaction conditions for the method: glutamate dehydrogenase, urease, 2-oxoglutarate, ADP, Tris . HCI, NADH, EDTA, pH, and temperature. The reagent is stable for at least 48 days at--20 degrees C and for 23 days at 4 degrees C. Mean analytical recovery of urea (14 mmol/L) added to seven different specimens (three different matrices) was 100.8%. The analytical linear range of the method extends to 30 mmol of urea per liter. Of 22 potential interferents, only bilirubin at 1 mmol/L (580 mg/L), hemoglobin at 10 g/L, and hydroxyurea at 6 mmol/L showed more than 2% interference. We discuss precision and effects of specimen dilution, and compare results for 100 human serum specimens with those measured for the same specimens with four other urea methods. We examined the effects of measuring a blank, consisting of sample and reagent without urease, with each specimen.

  11. Evidence for the field line reconnection process in the particle and magnetic field measurements obtained during the Giotto-Halley encounter

    Energy Technology Data Exchange (ETDEWEB)

    Kirsch, E.; Daly, P.; Korth, A.; McKenna-Lawlor, S.; Neubauer, F.M.; O' Sullivan, D.; Thompson, A.; Wenzel, K.P.

    1989-04-01

    Measurements of low (E = 250-1000 eV) and high (E = 60 to > 300 keV) energy particles as well as the magnetic field obtained by 3 different instruments (Reme Plasma Analyser, Energetic Particle Analyser, MAGnetometer) during the Giotto-Halley encounter on 13/14 March 1986 are used to study the field line merging process. Spikes of 5-15 min duration in the high energy particle flux which are superimposed on the general intensity time profile are correlated with minima in the low energy particle flux and time periods of oppositely directed magnetic field lines. Strong changes in the pitch angle distribution of energetic ions are observed simultaneously. The observations are considered as evidence for sporadic field line merging processes in the front side of Halley's cometosheath which can accelerate ions and electrons up to E /similar to/ 300 keV.

  12. The final power calibration of the IPEN/MB-01 nuclear reactor for various configurations obtained from the measurements of the absolute average neutron flux

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alexandre Fonseca Povoa da, E-mail: alexandre.povoa@mar.mil.br [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil); Bitelli, Ulysses d' Utra; Mura, Luiz Ernesto Credidio; Lima, Ana Cecilia de Souza; Betti, Flavio; Santos, Diogo Feliciano dos, E-mail: ubitelli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The use of neutron activation foils is a widely spread technique applied to obtain nuclear parameters then comparing the results with those calculated using specific methodologies and available nuclear data. By irradiation of activation foils and subsequent measurement of its induced activity, it is possible to determine the neutron flux at the position of irradiation. The power level during operation of the reactor is a parameter which is directly proportional to the average neutron flux throughout the core. The objective of this work is to gather data from irradiation of gold foils symmetrically placed along a cylindrically configured core which presents only a small excess reactivity in order to derive the power generated throughout the spatial thermal and epithermal neutron flux distribution over the core of the IPEN/MB-01 Nuclear Reactor, eventually lending to a proper calibration of its nuclear channels. The foils are fixed in a Lucite plate then irradiated with and without cadmium sheaths so as to obtain the absolute thermal and epithermal neutron flux. The correlation between the average power neutron flux resulting from the gold foils irradiation, and the average power digitally indicated by the nuclear channel number 6, allows for the calibration of the nuclear channels of the reactor. The reactor power level obtained by thermal neutron flux mapping was (74.65 ± 2.45) watts to a mean counting per seconds of 37881 cps to nuclear channel number 10 a pulse detector, and 0.719.10{sup -5} ampere to nuclear linear channel number 6 (a non-compensated ionization chamber). (author)

  13. UV-Visible intensity ratio (aggregates/single particles) as a measure to obtain stability of gold nanoparticles conjugated with protein A

    Energy Technology Data Exchange (ETDEWEB)

    Rios-Corripio, M. A. [Instituto Politecnico Nacional, CIBA-Tlaxcala (Mexico); Garcia-Perez, B. E. [Instituto Politecnico Nacional, Departamento de Inmunologia, ENCB (Mexico); Jaramillo-Flores, M. E. [Instituto Politecnico Nacional, Departamento de Ingenieria Bioquimica, ENCB (Mexico); Gayou, V. L.; Rojas-Lopez, M., E-mail: marlonrl@yahoo.com.mx [Instituto Politecnico Nacional, CIBA-Tlaxcala (Mexico)

    2013-05-15

    We have analyzed the titration process of gold nanoparticles with several amounts of protein A (0.3, 0.5, 1, 3, 6, and 9 {mu}g/ml) in the presence of NaCl, which induces aggregation if the surface of particles is not fully covered with protein A. The colloidal solutions with different particle size (16, 18, 20, 33 nm) were synthesized by citrate reduction to be conjugated with protein A. UV-Visible spectroscopy was used to measure the absorption of the surface plasmon resonance of gold nanoparticles as a function of the concentration of protein A. Such dependence shows an aggregation region (0 < x<6 {mu}g/ml), where the amount of protein A was insufficient to cover the surface of particles, obtaining aggregation caused by NaCl. The next part is the stability region (x {>=} 6 {mu}g/ml), where the amount of protein used covers the surface of particles and protects it from the aggregation. In addition to that the ratio between the intensities of both: the aggregates and of the gold nanoparticle bands was plotted as a function of the concentration of protein A. It was determined that 6 {mu}g/ml is a sufficient value of protein A to stabilize the gold nanoparticle-protein A system. This method provides a simple way to stabilize gold nanoparticles obtained by citrate reduction, with protein A.

  14. Spectrally resolved measurement of the ion feature in the scattered spectrum of a hydrogen plasma obtained with a periodically pulsed Nd3+: YAG-laser

    International Nuclear Information System (INIS)

    Kasparek, W.

    Ion temperature and density in a magnetically stabilized hydrogen arc were determined with laser scattering from collective electron density fluctuations. A 90 0 -scattering experiment was set up using a periodically pulsed Nd 3+ : YAG-laser, an IR-photomultiplier and synchronous signal detection. A spectral resolution of 0.3 Angstroem was achieved by narrowing the laser line width and by using a Fabry-Perot-interferometer in combination with a monochromator as spectrometer. The data obtained from the scattered spectra (Tsub(i) = 1,1 ... 1,8 eV, nsub(e) = 2 ... 6 x 10 21 m -3 ) agree well with those obtained by other methods. The achieved high resolution also allowed to measure separately the ion features of two ion species with different mass, which are spectrally distinguished from each other. The results confirm the theoretical model of Evans. Demixing effects in a H 2 /A mixture as well as a temperature difference between the ion sorts are deduced. (orig.) 891 HT/orig. 892 HIS

  15. Relationships among measurements obtained by use of computed tomography and radiography and scores of cartilage microdamage in hip joints with moderate to severe joint laxity of adult dogs.

    Science.gov (United States)

    Lopez, Mandi J; Lewis, Brooke P; Swaab, Megan E; Markel, Mark D

    2008-03-01

    To evaluate correlations among measurements on radiographic and computed tomography (CT) images with articular cartilage microdamage in lax hip joints of dogs. 12 adult mixed-breed hounds. Pelvic CT and radiography were performed. Hip joints were harvested following euthanasia. Orthopedic Foundation for Animals (OFA) and PennHIP radiograph reports were obtained. Norberg angle (NA) and radiographic percentage femoral head coverage (RPC) were determined. Center-edge angle (CEA), horizontal toit externe angle (HTEA), ventral acetabular sector angle (VASA), dorsal acetabular sector angle (DASA), horizontal acetabular sector angle (HASA), acetabular index (AI), and CT percentage femoral head coverage (CPC) were measured on 2-dimensional CT images. Femoral head-acetabular shelf percentage was measured on sagittal 3-dimensional CT (SCT) and transverse 3-dimensional CT (TCT) images. Light microscopy was used to score joint cartilage. Relationships of OFA confirmation and PennHIP osteoarthritis scores with radiography, CT, and cartilage variables and relationships of cartilage scores with radiography and CT measurements were evaluated with Spearman rank correlations. Pearson correlation was used for relationships of distraction index (DI) with radiography, CT, and cartilage variables. Significant relationships included PennHIP osteoarthritis score with cartilage score, CEA, HTEA, DASA, AI, CPC, and TCT; OFA confirmation score with cartilage score, NA, RPC, CEA, HTEA, DASA, AI, CPC, and TCT; cartilage score with NA, RPC, CEA, HTEA, DASA, HASA, AI, and TCT; and DI with cartilage score, CEA, HTEA, DASA, HASA, AI, and CPC. CT appeared to be a valuable imaging modality for predicting cartilage microdamage in canine hip joints.

  16. Clinical evaluation of the Serum CrossLaps One Step ELISA, a new assay measuring the serum concentration of bone-derived degradation products of type I collagen C-telopeptides

    DEFF Research Database (Denmark)

    Christgau, S; Rosenquist, C; Alexandersen, P

    1998-01-01

    The Serum CrossLaps One Step ELISA is a sandwich assay using two monoclonal antibodies specific for a beta-aspartate form of the epitope EKAHDGGR derived from the carboxy-terminal telopeptide region of type I collagen alpha1-chain. Our objective was to assess the clinical value of the Serum Cross...

  17. Reference Ranges of Serum Blood Urea Nitrogen, Creatinine Concentration and Ultrasonographic Measurement of the Kidneys in Term Healthy Newborns in the Neonatal Period

    Directory of Open Access Journals (Sweden)

    Şebnem Kader

    2017-12-01

    Full Text Available Objective: Acute kidney injury is an important problem in neonates. We conducted a cross-sectional prospective study to determine normal serum blood urea nitrogen, creatinine reference ranges and ranges of ultrasonographic measurement of kidneys in healthy term newborns. Study Design: Blood samples were collected from total 357 healthy newborns at birth (n=45, 1st (n=30, 3rd (n=61, 7th (n=34, 10th (n=132, 14th (n=36, and 28th (n=19 days of life. Renal ultrasonographic was performed by the same two radiologists on 81 newborns aged 10 days. Results: Serum blood urea nitrogen and creatinine concentrations have reached to the highest level at the first day of life and have returned to cord level at the third day of life. There were gradually decrease in serum blood urea nitrogen and creatinine levels after the first day of life. There were significant difference in both right and left renal length, width, and volumes in terms of gender and these parameters were statistically higher in boys than girls (p<0.05. Birth weight of the boys (3548±539g was statistically higher than girls (3307±405 g (p=0.028. There was a positive correlation between birth weight and right (r=0.38, p=0.000 and left kidney volumes (r=0.44, p=0.000. Conclusion: Our findings showed that measured blood urea nitrogen and creatinine levels changed in accordance with postnatal days and there was a positive correlation between kidney volume and birth weight of newborns. We concluded that these findings are important for evaluation of acute kidney injury and for screening of for urinary tract anomalies in neonates

  18. Measurement of guided mode wave vectors by analysis of the transfer matrix obtained with multi-emitters and multi-receivers in contact

    Energy Technology Data Exchange (ETDEWEB)

    Minonzio, Jean-Gabriel; Talmant, Maryline; Laugier, Pascal, E-mail: jean-gabriel.minonzio@upmc.fr [UPMC Univ Paris 06, UMR 7623, LIP, 15 rue de l' ecole de medecine F-75005, Paris (France)

    2011-01-01

    Different quantitative ultrasound techniques are currently developed for clinical assessment of human bone status. This paper is dedicated to axial transmission: emitters and receivers are linearly arranged on the same side of the skeletal site, preferentially the forearm. In several clinical studies, the signal velocity of the earliest temporal event has been shown to discriminate osteoporotic patients from healthy subjects. However, a multi parameter approach might be relevant to improve bone diagnosis and this be could be achieved by accurate measurement of guided waves wave vectors. For clinical purposes and easy access to the measurement site, the length probe is limited to about 10 mm. The limited number of acquisition scan points on such a short distance reduces the efficiency of conventional signal processing techniques, such as spatio-temporal Fourier transform. The performance of time-frequency techniques was shown to be moderate in other studies. Thus, optimised signal processing is a critical point for a reliable estimate of guided mode wave vectors. Toward this end, a technique, taking benefit of using both multiple emitters and multiple receivers, is proposed. The guided mode wave vectors are obtained using a projection in the singular vectors basis. Those are determined by the singular values decomposition of the transmission matrix between the two arrays at different frequencies. This technique enables us to recover accurately guided waves wave vectors for moderately large array.

  19. Usefulness of Time-Point Serum Cortisol and ACTH Measurements for the Adjustment of Glucocorticoid Replacement in Adrenal Insufficiency.

    Science.gov (United States)

    Rousseau, Elise; Joubert, Michael; Trzepla, Géraldine; Parienti, Jean Jacques; Freret, Thomas; Vanthygem, Marie Christine; Desailloud, Rachel; Lefebvre, Hervé; Coquerel, Antoine; Reznik, Yves

    2015-01-01

    Adjustment of daily hydrocortisone dose on clinical criteria lacks sensitivity for fine tuning. Long term hydrocortisone (HC) over-replacement may lead to increased morbidity and mortality in patients with adrenal insufficiency (AI). Biochemical criteria may help detecting over- or under-replacement but have been poorly evaluated. Multicenter, institutional, pharmacokinetic study on ACTH and cortisol plasma profiles during HC replacement in 27 AI patients compared to 29 matched controls. All AI patients were administered HC thrice daily at doses of 6, 10 and 14 mg/m2/d. Blood samples were drawn hourly from 0800h to 1900h. The main outcome measures were: i) plasma peak cortisol and cortisol area under the curve (AUC) in AI patients compared to controls, ii) correlations between cortisol AUC vs single-point cortisol or ACTH decrease from baseline (ΔACTH) and iii) the predictive value of the two latters for obtaining AI patients' cortisol AUC in the control range. Cortisol peaks were observed 1h after each HC intake and a dose response was demonstrated for cortisol peak and cortisol AUC. The comparison of AI patients' cortisol AUC to controls showed that 81.5% AI patients receiving 6mg/m2/d were adequately replaced, whereas most patients receiving higher doses were over-replaced. The correlation coefficient between 1000h/1400h cortisol concentrations and 0800-1900h cortisol AUC were 0.93/0.88 respectively, whereas the 0800-1200h ΔACTH fairly correlated with 0800-1900h cortisol AUC (R = 0.57). ROC curve analysis indicated that the 1000h and 1400h cortisol concentrations best predicted over-replacement. Patients receiving a 6mg/m2 hydrocortisone daily dose exhibited the most physiological daytime cortisol profile. Single point plasma cortisol correlated with daytime cortisol AUC in AI patients. Although hydrocortisone dose should be currently determined on clinical grounds, our data suggest that single point plasma cortisol may be an adjunct for further hydrocortisone

  20. Comparison of precipitation chemistry measurements obtained by the Canadian Air and Precipitation Monitoring Network and National Atmospheric Deposition Program for the period 1995-2004

    Science.gov (United States)

    Wetherbee, Gregory A.; Shaw, Michael J.; Latysh, Natalie E.; Lehmann, Christopher M.B.; Rothert, Jane E.

    2010-01-01

    Precipitation chemistry and depth measurements obtained by the Canadian Air and Precipitation Monitoring Network (CAPMoN) and the US National Atmospheric Deposition Program/National Trends Network (NADP/NTN) were compared for the 10-year period 1995–2004. Colocated sets of CAPMoN and NADP instrumentation, consisting of precipitation collectors and rain gages, were operated simultaneously per standard protocols for each network at Sutton, Ontario and Frelighsburg, Ontario, Canada and at State College, PA, USA. CAPMoN samples were collected daily, and NADP samples were collected weekly, and samples were analyzed exclusively by each network’s laboratory for pH, H + , Ca2+  , Mg2+  , Na + , K + , NH+4 , Cl − , NO−3 , and SO2−4 . Weekly and annual precipitation-weighted mean concentrations for each network were compared. This study is a follow-up to an earlier internetwork comparison for the period 1986–1993, published by Alain Sirois, Robert Vet, and Dennis Lamb in 2000. Median weekly internetwork differences for 1995–2004 data were the same to slightly lower than for data for the previous study period (1986–1993) for all analytes except NO−3 , SO2−4 , and sample depth. A 1994 NADP sampling protocol change and a 1998 change in the types of filters used to process NADP samples reversed the previously identified negative bias in NADP data for hydrogen-ion and sodium concentrations. Statistically significant biases (α = 0.10) for sodium and hydrogen-ion concentrations observed in the 1986–1993 data were not significant for 1995–2004. Weekly CAPMoN measurements generally are higher than weekly NADP measurements due to differences in sample filtration and field instrumentation, not sample evaporation, contamination, or analytical laboratory differences.

  1. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    Science.gov (United States)

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; Psamples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  2. Release of Gentamicin and Vancomycin from Preformed Spacers in Infected Total Hip Arthroplasties: Measurement of Concentrations and Inhibitory Activity in Patients’ Drainage Fluids and Serum

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2013-01-01

    Full Text Available Gentamicin (G and vancomycin (V concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips were treated by implantation of industrial G-loaded spacers. Vancomycin was added by manually mixing with PMMA bone cement. Serum and drainage fluid samples were collected 1, 4, and 24 hours after spacer implantation. Antibiotics concentrations and drains bactericidal titer of combination were determined against multiresistant staphylococcal strains. The release of G and V from PMMA cement at the site of infection was prompt and effective. Serum levels were below the limit of detection. The local release kinetics of G and V from PMMA cement was similar, exerting a pronounced, combined inhibitory effect in the implant site. The inhibitory activity of drainage fluids showed substantial intersubject variability related to antibiotic concentrations and differed according to the pathogens tested. Gentamicin and vancomycin were released from temporary hip spacers at bactericidal concentrations, and their use in combination exerted strong inhibition against methicillin-resistant S. aureus and Coagulase Negative Staphylococci strains.

  3. Serum immunoglobulin free light-chain measurement in primary amyloidosis: prognostic value and correlations with clinical features.

    Science.gov (United States)

    Kumar, Shaji; Dispenzieri, Angela; Katzmann, Jerry A; Larson, Dirk R; Colby, Colin L; Lacy, Martha Q; Hayman, Suzanne R; Buadi, Francis K; Leung, Nelson; Zeldenrust, Steve R; Ramirez-Alvarado, Marina; Clark, Raynell J; Kyle, Robert A; Rajkumar, S Vincent; Gertz, Morie A

    2010-12-09

    Immunoglobulin free light chains (FLCs) are the precursors of amyloid fibrils in primary amyloidosis (AL). We studied the relationship between FLC levels and clinical features in 730 patients with newly diagnosed AL. The plasma cell clone was λ in 72% patients, and κ in 28% patients. κ-AL had more GI tract and liver involvement, where as renal involvement was more with λ-AL. While the overall survival (OS) was similar for κ and λ-AL, the median OS for those without an identifiable serum heavy chain was significantly shorter (12.6 vs 29.9 months; P = .02). The OS was shorter among those with a higher dFLC (involved FLC-uninvolved FLC; κ > 29.4 mg/dL or λ > 18.2 mg/dL using median for cutoff); 10.9 vs 37.1 months; P analysis, dFLC was independent of other prognostic factors. The type of light chain impacts the spectrum of organ involvement and the FLC burden correlates with survival in AL.

  4. Radioimmunological oestrogen and progesterone measurement in the serum and ovaries of pseudogravid female rats after PMS and HCG treatment

    International Nuclear Information System (INIS)

    Hauck, P.

    1978-01-01

    Infantile female rats were made pseudogravid with PMS-HCG (according to Karg). Two bioassays were employed to investigate the effects of HCG on the ovaries; the HCG was injected subactaneously in the back of the animals in varying doses and at various intervals after the initial PMS administration. As specific parameters, oestrogen and progesterone levels in serum and ovary homogenate were determined radioimmunologically. The first animal experiment showed that the ovaries of pseudogravid animals had reached maximum sensitivity for corpus luteum production after HCG administration between 50 and 70 hours after PMS administration. In the second animal experiment with repeated HCG stimulus in the luteal phase, it was found that the corpus luteum of the rat ovary is apparently unable to synthesize oestrogens. In contrast, progesteron synthesis received maximum stimulation already with the lowest dose administered (3 IE HCG). The experiments clearly showed a dependence on HCG dose and the time which the test substance is allowed to take effect. (orig./AJ) 891 AJ/orig.- 892 KN [de

  5. A comparison of long-term parallel measurements of sunshine duration obtained with a Campbell-Stokes sunshine recorder and two automated sunshine sensors

    Science.gov (United States)

    Baumgartner, D. J.; Pötzi, W.; Freislich, H.; Strutzmann, H.; Veronig, A. M.; Foelsche, U.; Rieder, H. E.

    2017-06-01

    In recent decades, automated sensors for sunshine duration (SD) measurements have been introduced in meteorological networks, thereby replacing traditional instruments, most prominently the Campbell-Stokes (CS) sunshine recorder. Parallel records of automated and traditional SD recording systems are rare. Nevertheless, such records are important to understand the differences/similarities in SD totals obtained with different instruments and how changes in monitoring device type affect the homogeneity of SD records. This study investigates the differences/similarities in parallel SD records obtained with a CS and two automated SD sensors between 2007 and 2016 at the Kanzelhöhe Observatory, Austria. Comparing individual records of daily SD totals, we find differences of both positive and negative sign, with smallest differences between the automated sensors. The larger differences between CS-derived SD totals and those from automated sensors can be attributed (largely) to the higher sensitivity threshold of the CS instrument. Correspondingly, the closest agreement among all sensors is found during summer, the time of year when sensitivity thresholds are least critical. Furthermore, we investigate the performance of various models to create the so-called sensor-type-equivalent (STE) SD records. Our analysis shows that regression models including all available data on daily (or monthly) time scale perform better than simple three- (or four-) point regression models. Despite general good performance, none of the considered regression models (of linear or quadratic form) emerges as the "optimal" model. Although STEs prove useful for relating SD records of individual sensors on daily/monthly time scales, this does not ensure that STE (or joint) records can be used for trend analysis.

  6. Measurements of auto-antibodies to α-synuclein in the serum and cerebral spinal fluids of patients with Parkinson's disease.

    Science.gov (United States)

    Akhtar, Rizwan S; Licata, Joseph P; Luk, Kelvin C; Shaw, Leslie M; Trojanowski, John Q; Lee, Virginia M-Y

    2018-03-03

    Biomarkers for α-synuclein are needed for diagnosis and prognosis in Parkinson's disease (PD). Endogenous auto-antibodies to α-synuclein could serve as biomarkers for underlying synucleinopathy, but previous assessments of auto-antibodies have shown variability and inconsistent clinical correlations. We hypothesized that auto-antibodies to α-synuclein could be diagnostic for PD and explain its clinical heterogeneity. To test this hypothesis, we developed an enzyme-linked immunosorbent assay for measuring α-synuclein auto-antibodies in human samples. We evaluated 69 serum samples (16 healthy controls (HC) and 53 PD patients) and 145 CSF samples (52 HC and 93 PD patients) from our Institution. Both serum and CSF were available for 24 participants. Males had higher auto-antibody levels than females in both fluids. CSF auto-antibody levels were significantly higher in PD patients as compared to HC, whereas serum levels were not significantly different. CSF auto-antibody levels did not associate with amyloid-β 1-42 , total tau, or phosphorylated tau. CSF auto-antibody levels correlated with performance on the Montreal Cognitive Assessment, even when controlled for CSF amyloidβ 1-42 . CSF hemoglobin levels, as a proxy for contamination of CSF by blood during lumbar puncture, did not influence these observations. Using recombinant α-synuclein with N- and C-terminal truncations, we found that CSF auto-antibodies target amino acids 100 through 120 of α-synuclein. We conclude that endogenous CSF auto-antibodies are significantly higher in PD patients as compared to HC, suggesting that they could indicate the presence of underlying synucleinopathy. These auto-antibodies associate with poor cognition, independently of CSF amyloidβ 1-42 ., and target a select C-terminal region of α-synuclein. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Validation of a serum immunoassay to measure progesterone and diagnose pregnancy in the West Indian manatee (Trichechus manatus)

    Science.gov (United States)

    Tripp, K.M.; Verstegen, J.P.; Deutsch, C.J.; Bonde, R.K.; Rodriguez, M.; Morales, B.; Schmitt, D.L.; Harr, K.E.

    2008-01-01

    The objective was to validate a high-sensitivity chemiluminescent assay of serum progesterone concentrations for pregnancy diagnosis in manatees. Assay analytical sensitivity was 0.1 ng/mL, with mean intra- and inter-assay coefficients of variation of 9.7 and 9.2%, respectively, and accuracy had a mean adjusted R2 of 0.98. Methods comparison (relative to Siemen's Coat-A-Count RIA) demonstrated r = 0.98, Deming regression slope of 0.95, and an intercept of 0.01. Based on ROC analysis, a progesterone concentration ???0.4 ng/mL was indicative of pregnancy. Assay results were not significantly altered by two freeze-thaw cycles of samples. Characteristic progesterone concentrations during pregnancy were Months 1-4 (1.7-4.7 ng/mL), 5-8 (???1.0 ng/mL), and 10 and 11 (0.3-0.5 ng/mL), whereas two late-pregnant females with impending abortion had progesterone concentrations of 0.1 ng/mL. Among pregnant females, maximum progesterone concentrations occurred in autumn (3.9 ?? 1.8 ng/mL), and were greater during all seasons than concentrations in non-pregnant females (0.1-0.2 ng/mL). Progesterone concentrations were also significantly higher in pregnant females than in non-pregnant females and males. This highly sensitive, specific, and diagnostic assay will be valuable for monitoring pregnancy and abortion in manatees. ?? 2008 Elsevier Inc.

  8. Cancer risk in relation to serum copper levels.

    Science.gov (United States)

    Coates, R J; Weiss, N S; Daling, J R; Rettmer, R L; Warnick, G R

    1989-08-01

    A nested, matched case-control study was conducted to assess the relationship between serum levels of copper and the subsequent risk of cancer. One hundred thirty-three cases of cancer were identified during 1974-1984 among 5000 members of a northwest Washington State employee cohort from whom serum specimens had been previously obtained and stored. Two hundred forty-one controls were selected at random from the cohort and were matched to the cases on the basis of age, sex, race, and date of blood draw. Serum copper levels were measured by atomic absorption spectrometry. Risk of a subsequent diagnosis of cancer was positively associated with serum copper levels, but only among those cases diagnosed within 4 years of the time the serum specimens were collected. Among cases diagnosed more than 4 years after specimen collection, there was no consistent association between serum copper levels and risk. Adjustment for age, sex, race, occupational status, cigarette smoking, family history of cancer, alcohol consumption, and, among females, use of exogenous hormones had no appreciable effect on these relationships. The findings suggest that the presence of cancer may increase serum copper levels several years prior to its diagnosis. They are less supportive of the hypothesis that serum copper levels affect cancer risk.

  9. ELISA MEASUREMENT OF STACHYLYSIN (TM) IN SERUM TO QUANTIFY HUMAN EXPOSURES TO THE INDOOR MOLD STACHYBOTRYS CHARTARUM

    Science.gov (United States)

    Antibodies were produced against the hemolytic agent stachylysin obtained from the mold Stachybotryis chartarum. These antibodies were used to develop two enzyme-linked immunosorbent assay (ELISA) methods for the analysis of stachylysin in human and rat sera and environmental sa...

  10. Relationship between serum levels of triglycerides and vascular inflammation, measured as COX-2, in arteries from diabetic patients: a translational study

    Science.gov (United States)

    2013-01-01

    Background Inflammation is a common feature in the majority of cardiovascular disease, including Diabetes Mellitus (DM). Levels of pro-inflammatory markers have been found in increasing levels in serum from diabetic patients (DP). Moreover, levels of Cyclooxygenase-2 (COX-2) are increased in coronary arteries from DP. Methods Through a cross-sectional design, patients who underwent CABG were recruited. Vascular smooth muscle cells (VSMC) were cultured and COX-2 was measured by western blot. Biochemical and clinical data were collected from the medical record and by blood testing. COX-2 expression was analyzed in internal mammary artery cross-sections by confocal microscopy. Eventually, PGI2 and PGE2 were assessed from VSMC conditioned media by ELISA. Results Only a high glucose concentration, but a physiological concentration of triglycerides exposure of cultured human VSMC derived from non-diabetic patients increased COX-2 expression .Diabetic patients showed increasing serum levels of glucose, Hb1ac and triglycerides. The bivariate analysis of the variables showed that triglycerides was positively correlated with the expression of COX-2 in internal mammary arteries from patients (r2 = 0.214, P < 0.04). Conclusions We conclude that is not the glucose blood levels but the triglicerydes leves what increases the expression of COX-2 in arteries from DP. PMID:23642086

  11. Chlamydial serum IgG, IgA and local IgA antibodies in patients with genital-tract infections measured by solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Terho, P.; Meurman, O.

    1981-01-01

    A solid-phase radioimmunoassay (RIA) for IgG and IgA class antibodies to Chlamydia trachomatis was developed with C. trachomatis serotype L2 as antigen. The assay was sensitive, reproducible and correlated well with an immunofluorescence test (r = 0.85). Serum IgG antibodies were detected in 79% of Chlamydia isolation-positive versus 43% of isolation-negative male patients with urethritis and serum IgA antibodies in 53% and 21%, respectively. Urethral IgA antibodies, measured from specimens taken for chlamydial isolation, could be detected in 94% and 38%, respectively. From 737 male urethral and 909 female cervical secretions screened for the presence of IgA antibodies, about half were isolation and IgA negative. Only 4% (6/151) of male and 5.4% (2/37) of female isolation-positive specimens were IgA negative. The determination of local IgA antibodies may be used as a screening test in chlamydial genital infections. (author)

  12. Measurement of rhesus monkey (Macaca mulatta) apolipoprotein B in serum by radioimmunoassay: comparison of immunoreactivities of rhesus and human low density lipoproteins

    International Nuclear Information System (INIS)

    Karlin, J.B.; Juhn, D.J.; Fless, G.; Scanu, A.M.; Rubenstein, A.H.

    1978-01-01

    A sensitive and specific double antibody radioimmunoassay for the major apolipoprotein (apoB) of rhesus (Macaca mulatta) serum very low density lipoprotein (VLDL) and low density lipoprotein (LDL) is described. The antiserum was raised to LDL (d 1.030 to 1.040 g/ml) and the LDL 2 (d 1.020 to 1.050 g/ml) was labeled with 125 I by the chloramine-T or iodine monochloride method. The assay, which was sensitive to 0.02 to 0.5 μg of LDL 2 , had an interassay coefficient of variation of 4.5%. This assay was successfully used to measure apoB in the whole serum and low density lipoproteins of control monkeys maintained on a standard Purina monkey chow (PMC) diet and of three groups of monkeys fed atherogenic diets: an average American diet, a 25% peanut oil and 2% cholesterol-supplemented PMC diet, and a 25% coconut oil and 2% cholesterol-supplemented PMC diet

  13. Predictive value of mutant p53 expression index obtained from nonenhanced computed tomography measurements for assessing invasiveness of ground-glass opacity nodules

    Directory of Open Access Journals (Sweden)

    Wang W

    2016-03-01

    has a little higher area under the curve (AUC than the actual one both in differentiating MIAs from PIAs (AUC 0.938 vs 0.914, P=0.263 and in distinguishing IACs from MIAs (AUC 0.812 vs 0.786, P=0.718. Conclusion: p53-EI prediction of nGGOs obtained from CT measurements allows accurately estimating lesions’ pathology and invasiveness preoperatively not only from radiology but also from pathology. Keywords: ground-glass opacity, adenocarcinoma, computed tomography, CT, high-resolution computed tomography, HRCT, lung

  14. Serum YKL-40

    DEFF Research Database (Denmark)

    Mylin, Anne K; Abildgaard, Niels; Johansen, Julia S

    2015-01-01

    to clinical progression, i.e. skeletal-related events (SREs), in 230 newly diagnosed patients with multiple myeloma receiving intravenous bisphosphonates. Serum concentrations of YKL-40 and biochemical bone markers (CTX-MMP, CTX-I, PINP) were measured at diagnosis. Patients were evaluated every third month...

  15. Data in support for the measurement of serum 25-hydroxyvitamin D (25OHD by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    M.E. Jensen

    2016-09-01

    Full Text Available This article provides data and a method related to a research paper entitled “Assessing vitamin D nutritional status: is capillary blood adequate?” (Jensen et al., 2016 [1]. Circulating 25OHD, the accepted biomarker of the vitamin D nutritional status, is routinely measured by automated immunoassays, that although may be performed in hospital central laboratories, often suffer from a lack of specificity with regards to the different vitamin D metabolites, “Measurement of circulating 25-hydroxyvitamin D: a historical review” (Le Goff et al., 2015 [2]. Mass spectrometry offers this specificity. This article describes the performance of an in-house tandem mass spectrometry method for the individual measurement of 25OHD3, 25OHD2 and 3-épi-25OHD3. Keywords: Vitamin D, 25-hydroxyvitamin D, Mass spectrometry

  16. Enhanced discrimination of benign from malignant prostatic disease by selective measurements of cleaved forms of urokinase receptor in serum

    DEFF Research Database (Denmark)

    Piironen, Timo; Haese, Alexander; Huland, Hartwig

    2006-01-01

    BACKGROUND: Early detection of prostate cancer (PCa) centers on measurements of prostate-specific antigen (PSA), but current testing practices suffer from lack of specificity and generate many unnecessary prostate biopsies. Soluble urokinase plasminogen activator receptor (uPAR) is present in blood...... in both intact and cleaved forms. Increased uPAR in blood is correlated with poor prognosis in various cancers, but uPAR has not been shown to be useful in PCa diagnostics. We assessed the ability of immunoassays for specific uPAR forms to discriminate PCa from benign conditions. METHODS: We measured...

  17. Radioimmunoassay of cholylglycine in serum

    International Nuclear Information System (INIS)

    Wakushima, Tadashi; Yamanishi, Yasuhito; Hirayama, Chisato

    1979-01-01

    Serum levels of cholylglycines (CG) were determined by radioimmunoassay and that of total bile acids (TBA) by enzymatic method. In normal subjects, serum levels of CG, TBA and CG/TBA ratio were 0.6 +- 0.4 μM, 7 +- 2 μM, and 0.08 +- 0.06, respectively. They were increased markedly in acute hepatitis and moderately in chronic hepatitis and cirrhosis. Thus, measurement of serum CG as compared with serum TBA appears to be a sensitive liver test. (author)

  18. Direct means of obtaining CAVI0-a corrected cardio-ankle vascular stiffness index (CAVI)-from conventional CAVI measurements or their underlying variables.

    Science.gov (United States)

    Spronck, Bart; Mestanik, Michal; Tonhajzerova, Ingrid; Jurko, Alexander; Jurko, Tomas; Avolio, Alberto P; Butlin, Mark

    2017-09-21

    significance Cardio-ankle vascular index (CAVI) as measured using the VaSera device (CAVI VS , Fukuda Denshi), has been proposed as a blood pressure-independent arterial stiffness index. We have recently shown theoretically that CAVI VS still exhibits pressure dependence, and proposed a corrected index, CAVI 0 . In the present study, we derived equations to directly obtain CAVI 0 using data from the VaSera device. Our results permit straightforward calculation of [Formula: see text] during a study, as well as retrospective estimation of [Formula: see text] from CAVI VS in already published studies, paving the way for thorough comparison of CAVI 0 to CAVI VS in clinical and research settings.

  19. Thyroglobulin (Tg) recovery testing with quantitative Tg antibody measurement for determining interference in serum Tg assays in differentiated thyroid carcinoma

    NARCIS (Netherlands)

    Persoon, ACM; Links, TP; Wilde, J; Sluiter, WJ; Wolffenbuttel, BHR; van den Ouweland, JMW

    Background: Thyroglobulin (Tg) measurements are complicated by interference from Tg autoantibodies (TgAbs) or heterophilic antibodies (HAMAs). We used a new automated immunochemiluminometric assay (ICMA) with Tg recovery (TgR) on the Nichols Advantage (R) platform to reassess the clinical utility of

  20. The Simultaneous measurement of serum testosterone and 5α-dihydrotestosterone by gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Kannenberg, Frank; Fobker, Manfred; Schulte, Erhard; Pierściński, Grzegorz; Kelsch, Reinhard; Zitzmann, Michael; Nofer, Jerzy-Roch; Schüring, Andreas N

    2018-01-01

    Simultaneous measurement of testosterone (T) and 5α-dihydrotestosterone (DHT) is important for diagnosing androgen deficiency states and hyperandrogenism in males and females, respectively. However, immunoassays used for T and DHT determination suffer from inadequate specificity and sensitivity, while tandem mass spectrometry is expensive and demanding in use. We developed a selective gas chromatography-mass spectrometry (GC-MS) method for parallel T and DHT measurement. The assay showed a linear response up to 46.5nmol/L, intra- and interassay imprecision and inaccuracy 90% for both analytes. The limit of quantitation was 0.117nmol/L for T and 0.168nmol/L for DHT. Comparison with immunoassays revealed good agreement for T in males, but a bias in favour of immunoassays at low concentrations for T in females and DHT in both sexes. We established reference ranges for T and DHT and suggest interval partitioning for T according to age in men and menstrual cycle in women. Assay validation in a clinical setting suggests that measuring DHT or T/DHT ratio may help identify patients with polycystic ovary syndrome. We developed a selective, simple and inexpensive GC-MS method for parallel measurement of T and DHT with potential use in the clinical laboratory. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Osteocalcin and serum insulin-like growth factor-1 as biochemical skeletal maturity indicators

    Directory of Open Access Journals (Sweden)

    Tulika Tripathi

    2017-10-01

    Full Text Available Abstract Background With change in concepts of growth determination methods, there is a surge in the measurement of biomarkers for appraisal of growth status. Osteocalcin is a bone-specific protein and was observed to parallel the normal growth curve. Hence, the present study was intended to assess the levels of serum osteocalcin and serum insulin-like growth factor-1 (IGF-1 and compare them with cervical vertebral maturation index (CVMI stages. Methods The cross-sectional study was performed on 150 subjects (75 males and 75 females in the age group of 8–20 years and segregated into six CVMI stages. Serum osteocalcin and IGF-1 were estimated by ELISA. Mann-Whitney U test was used to compare the mean ranks of serum osteocalcin and serum IGF-1 with different CVMI stages. Spearman correlation was performed to find association between serum osteocalcin and serum IGF-1 across six CVMI stages. Results Peak serum IGF-1 levels were obtained at CVMI stages 4 and 3 for males and females, respectively, with insignificant difference between stages 3 and 4 in females. Peak serum osteocalcin levels were found at stage 5 and 3 for males and females with insignificant difference from other stages except stages 5 and 6 in males. A statistically significant correlation was seen between serum IGF-1 and serum osteocalcin across six CVMI stages (P < 0.01. Conclusions Osteocalcin followed IGF-1 across all CVMI stages but showed insignificant interstage differences.

  2. Serum Creatinine: Not So Simple!

    Science.gov (United States)

    Delanaye, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). © 2017 S. Karger AG, Basel.

  3. Reappraisal of serum insulin-like growth factor-I (IGF-1) measurement in the detection of isolated and combined growth hormone deficiency (GHD) during the transition period.

    Science.gov (United States)

    Boguszewski, Cesar L; Lacerda, Claudio Silva de; Lacerda Filho, Luiz de; Carvalho, Julienne A R de; Boguszewski, Margaret C S

    2013-12-01

    To evaluate the accuracy of serum IGF-1 in the detection of isolated (IGHD) or combined growth hormone deficiency (CGHD) at the transition phase. Forty nine patients with GHD during childhood [16 with IGHD (10 men) and 33 with CGHD (24 men); age 23.2 ± 3.5 yrs.] were submitted to an insulin tolerance test (ITT) with a GH peak IGF-1 measurements were evaluated in the basal sample of the ITT. Transition patients were reclassified as GH-sufficient (SGH; n = 12), IGHD (n = 7), or CGHD (n = 30). Five (31%) patients with IGHD and 32 (97%) with CGHD at childhood persisted with GHD at retesting. One patient with IGHD was reclassified as CGHD, whereas 3 patients with CGHD were reclassified as IGHD. Mean GH peak was 0.2 ± 0.3 µg/L in the CGHD, 1.3 ± 1.5 µg/L in the IGHD, and 18.1 ± 13.1 µg/L in the SGH group. Serum IGF-1 level was significantly higher in the SGH (272 ± 107 ng/mL) compared to IGHD (100.2 ± 110) and CGHD (48.7 ± 32.8) (p IGF-1 level, resulting in 97.3% sensitivity and 91.6% specificity in the detection of GHD at the transition period; the cutoff value of 110 ng/mL showed 94.5% sensitivity and 100% specificity. Mean IGF-1 values did not differ in IGHD or CGHD associated with one, two, three, or four additional pituitary deficiencies. IGF-1 measurement is accurate to replace ITT as initial diagnostic test for IGHD and CGHD detection at the transition phase.

  4. The effect of sodium bicarbonate and validation of beckman coulter AU680 analyzers for measuring total carbon dioxide (TCO2) concentrations in horse serum.

    Science.gov (United States)

    Dirikolu, Levent; Waller, Pamela; Waguespack, Mona Landry; Andrews, Frank Michael; Keowen, Michael Layne; Gaunt, Stephen David

    2017-11-01

    This study evaluated the usage of Beckman Coulter AU680 analyzers for measurement of TCO 2 in horse serum, and the effect of sodium bicarbonate administrations on serum TCO 2 levels in resting horses. Treatment of horses with sodium bicarbonate did not result in any adverse events. Mean TCO 2 concentration was significantly higher from 1 to 8 h in the sodium bicarbonate-treated horses compared to the untreated controls. Within an hour, administration of sodium bicarbonate increased the TCO 2 level from 31.5 ± -2.5 (SD) to 34.0 ± 2.65 (SD) mmol/L and at 2-8 h post-administration, the TCO 2 level was above the 36 mmol/L cut-off level. In all quality control analysis of Australian standard by Beckman Coulter AU680 analyzer, the instrument slightly over estimated the TCO 2 level but the values were in close agreement with mean TCO 2 level being 38.03 with ± 0.87 mmol/L (SD). Expanded uncertainty was calculated using different levels of confidence interval. Based on 99.5% confidence interval using 0.805% expanded uncertainty using mean measured concentration of 38.05 mmol/L, it was estimated that any race samples TCO 2 level higher than 38.5 mmol/L will be indicative of sodium bicarbonate administration using Beckman Coulter AU680 analyzer in Louisiana.

  5. Clinical significance of measurement of changes of serum IL-2, SIL-2R levels, B lymphocyte number and T-cell subsets after chemotherapy in patients with malignant hydatidiform mole

    International Nuclear Information System (INIS)

    Zhang Guangcai

    2007-01-01

    Objective: To study the clinical significance of changes of serum IL-2, SIL-2R level, peripheral blood B lymphocyte number and T-cell subsets after chemotherapy in patients with malignant hydatidiform mole. Methods: Serum IL-2 ( with RIA), SIL-2R level (with ELISA) and peripheral blood B lymphocytes number as well as T subsets (with monoclonal antibody technique) were measured both before and after chemotherapy in 32 patients with malignant hydatidiform mole as well as in 35 controls. Results: Before chemotherapy serum SIL-2R level and B lymphocyte were significantly higher in the patients than those in controls (P<0.01), while the serum IL-2 level, CD3, CD4, CD4/CD8 were significantly lower (P<0.01). Six months after chemotherapy the levels changed markedly toward normal, but remained significantly different from those in controls (P<0.05). Conclusion: Abnormal immuno-regulation were present in patients with malignant mole. (authors)

  6. Nanoduct Sweat Conductivity Measurements in 2664 Patients: Relationship to Age, Arterial Blood Gas, Serum Electrolyte Profiles and Clinical Diagnosis

    Science.gov (United States)

    Sezer, Rabia Gonul; Aydemir, Gokhan; Akcan, Abdullah Baris; Paketci, Cem; Karaoglu, Abdulbaki; Aydinoz, Secil; Bozaykut, Abdulkadir

    2013-01-01

    Background The Nanoduct® device has acceptable diagnostic accuracy, but there is not enough systematic data supporting its usage in the diagnosis of cystic fibrosis (CF). Methods A retrospective review of patients with an indication for the sweat test was conducted. The conductivity test was repeated in patients who had values higher than 60 mmol/L, and they were referred for sweat chloride measurements. Associations between sweat conductivity measurements and age, gender, (pH, HCO3, pCO2, Na, K, Cl), family history, consanguinity, indications for the test and number of hospitalization were studied. Results Among 2,664 patients, 16 children had sweat conductivity values higher than 80. The median age of patients diagnosed with CF was 4 months old. Age, pH, HCO3, Na, Cl, K and the sweat conductivity test were statistically related (P conductivity test and the sweat test. Conclusions Patients suspected to have CF can be screened using the Nanoduct® conductivity device in non-qualified centers. PMID:23390474

  7. Measurement of serum free thyroxine using fT4(fraction) determined by solidphase radioimmunoassay: First clinical results

    International Nuclear Information System (INIS)

    Reiners, C.; Walter, H.; Moll, E.; Boerner, W.

    1983-01-01

    The novel solidphase RIA SPAC ET permits the simultaneous determination of TF 4 , TT 4 and fT 4 -fraction. The duration until the complete results of this assay can be obtained is a little bit less than for parallel radioimmunologic FT 4 - and TT 4 -determinations. The results of our quality control survey indicate that the precision of the precommercial kits tested should be improved. In addition, the normal range of FT 4 from 5.5 pg/ml to 12.5 pg/ml should be adapted in the final assay version of the approximately 30% higher normal ranges which are common with alternative FT 4 -radioimunoassays. In comparison to FT 4 -I, TT 4 /TBG-ratio and other FT 4 -radioimmunoassays, the diagnostic accuracy of FT 4 determined by SPAC ET is equally good. Estrogen-mediated TBG elevations on oral contraceptives are well compensated. In pregnancy, the known tendency towards lower FT 4 levels can be seen with the beginning of the second trimester. While there are no changes of FT 4 levels on medication with acetylosalicyclic acid, a slight tendency towards lower FT 4 determined by SPAC ET can be seen on therapy with phenytoin. Under treatment with heparin, FT 4 by SPAC ET is elevated. This is more reasonable than the decreases of FT 4 concentrations observed with radioimmunoassays using FT 4 analogues as tracers. RIA SPAC ET is an interesting alternative to routinely used direct and indirect methods for determination of free thyroxine. (orig.) [de

  8. Serum myostatin is reduced in individuals with metabolic syndrome.

    Directory of Open Access Journals (Sweden)

    Der-Sheng Han

    Full Text Available Myostatin is a negative regulator of skeletal muscle mass and may also modulate energy metabolism secondarily. We aim to investigate the relationship between serum myostatin and the metabolic variables in diabetic (DM and non-diabetic subjects.A cross-sectional study recruiting 246 consecutive DM patients and 82 age- and gender-matched non-diabetic individuals at a medical center was conducted. The variables of anthropometry and blood chemistry were obtained. Serum myostatin level was measured with enzyme immunoassay.DM group had lower serum myostatin compared with non-diabetics (7.82 versus 9.28 ng/ml, p<0.01. Sixty-two percent of the recruited individuals had metabolic syndrome (MetS. The patients with MetS had significantly lower serum myostatin than those without (7.39 versus 9.49 ng/ml, p<0.001. The serum myostatin level decreased with increasing numbers of the MetS components (p for trend<0.001. The patients with higher body mass index, larger abdominal girth, lower high-density lipoprotein cholesterol (HDL-C, and higher triglycerides had lower serum myostatin than those without. The serum myostatin level was independently negatively related to larger abdominal girth, higher triglycerides, and lower HDL-C after adjustment. The odds ratios for MetS, central obesity, low HDL-C, high triglycerides, and DM were 0.85, 0.88, 0.89, 0.85, and 0.92, respectively, when serum myostatin increased per 1 ng/mL, in the binary logistic regression models.Lower serum myostatin independently associated with MetS, central obesity, low HDL-C, and high triglycerides after adjustment. Higher serum myostatin is associated with favorable metabolic profiles.

  9. Antibody response to the lipopolysaccharide and protein antigens of Salmonella typhi during typhoid infection. I. Measurement of serum antibodies by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, R S.W.; Chau, P Y; Lam, S K [Hong Kong Univ.; La Brooy, J T; Rowley, D [Adelaide Univ. (Australia)

    1981-12-01

    Serum antibody responses to the lipopolysaccharide and protein antigens of S. typhi in typhoid patients were studied using a solid-phase radioimmunoassay technique with /sup 125/I labelled anti-immunoglobulin antibody. Sera from 24 adult typhoid patients and 20 non-typhoid adult controls were compared. As a group, sera from typhoid patients showed increased IgA, IgG and IgM immunoglobulin levels and gave significantly higher anti-LPS and anti-protein antibody titres in all three major immunoglobulin classes than did non-typhoid controls. Levels of antibodies against LPS or protein in sera of typhoid patients were highly variable with a skew distribution. A good correlation was found between antibody titres to the LPS antigen and those to a protein antigen. No correlation, however, was found between the anti-LPS antibody titres measured by radioimmunoassay and the anti-O antibody titres measured by the Widal agglutination test. Titration of anti-LPS or anti-protein antibodies by radioimmunoassay was found to be more sensitive and specific than Widal test for the serological diagnosis of typhoid fever. The advantages of measuring antibody response by radioimmunoassay over conventional Widal test are discussed.

  10. Rapid and Precise Measurement of Serum Branched-Chain and Aromatic Amino Acids by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry

    OpenAIRE

    Yang, Ruiyue; Dong, Jun; Guo, Hanbang; Li, Hongxia; Wang, Shu; Zhao, Haijian; Zhou, Weiyan; Yu, Songlin; Wang, Mo; Chen, Wenxiang

    2013-01-01

    BACKGROUND: Serum branched-chain and aromatic amino acids (BCAAs and AAAs) have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. METHODS: An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standar...

  11. Measurement of serum FT3 and FT4 in patients with chronic renal failure and its clinical significance

    International Nuclear Information System (INIS)

    Tan Qingling; Zhang Hui

    2003-01-01

    Objective: To investigate the changes of thyroid hormones in patients with chronic renal failure (CRF) and it's clinical significance. Methods: FT 3 , FT 4 and TSH levels were measured with radioimmunoassay for 42 CRF patients (42 CRF patients were subdivided into uremia and azotemia) and 18 cases of renal disease patients with a normal renal function. Results: Levels of FT 3 , FT 4 and TSH in uremia group and azotemia group were significantly lower than that of normal renal function group (P 3 , FT 4 and TSH in uremia group were remarkably lower than azotemia group (P 3 , FT 4 in patients with CRF can reflect the severity of renal function damage, and can also be an important prognosis index

  12. Clinical significance of measurement of changes of serum IL-6, IL-18 and IL-1β levels after treatment in patients with endometriosis

    International Nuclear Information System (INIS)

    Zhang Chunyan; Zhang Shumin; Zhou Dongxia; Wang Enbo

    2008-01-01

    Objective: To explore the clinical significance of changes of serum IL-6, IL-18 and IL-1β levels after treatment in patients with endometriosis. Methods: Serum IL-6 (with RIA) and IL-18, IL-1β (with ELISA) levels were determined in 38 patients with endometriosis both before and after treatment as well as 35 controls. Results: Before treatment, the serum IL-6, IL- 18 and IL-1β levels were significantly higher in the patients than those in controls (P 0.05). Conclusion: Detection of serum IL-6, IL-18 and IL- 1β levels might reflect the progress of diseases in patients with endometriosis. (authors)

  13. Serum Myostatin Is Reduced in Individuals with Metabolic Syndrome

    Science.gov (United States)

    Chiang, Chih-Kang; Tseng, Fen-Yu; Tseng, Ping-Huei; Chen, Chi-Ling; Wu, Kwan-Dun; Yang, Wei-Shiung

    2014-01-01

    Aims Myostatin is a negative regulator of skeletal muscle mass and may also modulate energy metabolism secondarily. We aim to investigate the relationship between serum myostatin and the metabolic variables in diabetic (DM) and non-diabetic subjects. Materials and Methods A cross-sectional study recruiting 246 consecutive DM patients and 82 age- and gender-matched non-diabetic individuals at a medical center was conducted. The variables of anthropometry and blood chemistry were obtained. Serum myostatin level was measured with enzyme immunoassay. Results DM group had lower serum myostatin compared with non-diabetics (7.82 versus 9.28 ng/ml, pmyostatin than those without (7.39 versus 9.49 ng/ml, pmyostatin level decreased with increasing numbers of the MetS components (p for trendmyostatin than those without. The serum myostatin level was independently negatively related to larger abdominal girth, higher triglycerides, and lower HDL-C after adjustment. The odds ratios for MetS, central obesity, low HDL-C, high triglycerides, and DM were 0.85, 0.88, 0.89, 0.85, and 0.92, respectively, when serum myostatin increased per 1 ng/mL, in the binary logistic regression models. Conclusions Lower serum myostatin independently associated with MetS, central obesity, low HDL-C, and high triglycerides after adjustment. Higher serum myostatin is associated with favorable metabolic profiles. PMID:25254550

  14. Immunotoxicity of perfluorinated alkylates: calculation of benchmark doses based on serum concentrations in children

    DEFF Research Database (Denmark)

    Grandjean, Philippe; Budtz-Joergensen, Esben

    2013-01-01

    BACKGROUND: Immune suppression may be a critical effect associated with exposure to perfluorinated compounds (PFCs), as indicated by recent data on vaccine antibody responses in children. Therefore, this information may be crucial when deciding on exposure limits. METHODS: Results obtained from...... follow-up of a Faroese birth cohort were used. Serum-PFC concentrations were measured at age 5 years, and serum antibody concentrations against tetanus and diphtheria toxoids were obtained at ages 7 years. Benchmark dose results were calculated in terms of serum concentrations for 431 children...

  15. Serum gonadotropins levels in childhood

    International Nuclear Information System (INIS)

    Hertogh, R. De; Vankrieken, L.; Wolter, R.; Vliet, G. Van

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author)

  16. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

    NARCIS (Netherlands)

    Wiranto, Matthew G.; Engelbrecht, W. Petrie; Nolthenius, Heleen E. Tutein; van der Meer, W. Joerd; Ren, Yijin

    INTRODUCTION: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans

  17. Evaluation of clinical state of patients with acute leukemia, multiple myeloma and malignant lymphoma by means of in vitro T1 and T2 measurements in serum

    International Nuclear Information System (INIS)

    Kuliszkiewicz-Janus, M.; Urbaniak-Kujda, D.; Burczak, K.

    1995-01-01

    A dynamic relaxation times T1 and T2 in vitro study has been performed in the human sera of patients with haematological malignant diseases to monitor their clinical state. Two hundred studies were performed in 20 healthy volunteers and in 180 patients with different malignancies, mostly: acute leukemia, Hodgkin's disease, non-Hodgkin's lymphomas, multiple myeloma. Determinations were performed in active phase of disease and in remission. Measurements were carried out on spectrometer Minispect PC 20B (Bruker; 20 MHz) in 27 C. Additionally, serum proteins of all patients were examined, including total protein content, serum electrophoresis and measurement of Ig classes. Remarkable increase of T1 values in active phase of the disease was found (compared to healthy volunteers) in all malignancies, except multiple myeloma. It was associated with the severeness of the illness, not with diagnose. During remission T1 values did not differ significantly from those of healthy persons. All sera of patients with multiple myeloma in active phase of the disease showed strongly reduced values of T1, associated with the high level of pathological proteins. In 45 patients the measurements were repeated up to 4 times before and during chemotherapy. During treatment resulting in remission, mean T1 values progressively decreased (from 1560 ms to 1394 ms) except of those patients with multiple myeloma. In persons non-responding to therapy these mean values were prolonged (from 1474 ms to 1620 ms) during therapy. In patients with multiple myeloma we noted the reverse changes of mean T1 values in comparison with other malignancies: those responding to the treatment revealed prolonged T1 (from 1165 to 1303 ms) while in those non-responding were decreased (from 1184 ms to 1158 ms). Statistically significant negative correlation was observed between the T1 and total protein content, percentage of gamma-globulin, especially of IgG class. Moreover, a remarkable positive correlation of T1

  18. A possible experiment with two counter-orbiting drag-free satellites to obtain a new test of Einstein's general theory of relativity and improved measurements in geodesy

    Science.gov (United States)

    Van Patten, R. A.; Everitt, C. W. F.

    1976-01-01

    In 1918, Lense and Thirring calculated that a moon in orbit around a massive rotating planet would experience a nodal dragging effect due to general relativity. We describe an experiment to measure this effect by means of two counter-orbiting drag-free satellites in polar orbit about the earth. For a 2-1/2 year experiment, the measurement should approach an accuracy of 1%. An independent measurement of the geodetic precession of the orbit plane due to the motion about the sun may also be possible to about 10% accuracy. In addition to precision tracking data from existing ground stations, satellite-to-satellite Doppler data are taken at points of passing near the poles to yield an accurate measurement of the separation distance between the two satellites. New geophysical information on both earth harmonics and tidal effects is inherent in this polar ranging data.

  19. Clinical significance of measurement of changes of plasma NPY, CGRP and serum IGF-I levels in patients with acute cerebral infarction

    International Nuclear Information System (INIS)

    Deng Weiqun; Zhao Yushan

    2007-01-01

    Objective: To investigate the clinical significance of changes of plasma NPY, CGRP and serum IGF-I levels in patients with acute cerebral infarction. Methods: Plasma NPY, CGRP and serum IGF-I levels were determined with RIA in 32 patients with acute cerebral infarction both before and after treatment and 30 controls. Results: Before treatment plasma NPY levels were significantly higher (P<0.01) than those in the controls, while plasma CGRP and serum IGF-I levels were lower than those in controls (P<0.01). After treatment, plasma NPY levels decreased significantly (vs before treatment P<0.05), and plasma CGRP and serum IGF-I levels increased (P<0.05). Conclusion: Changes of plasma NPY, CGRP and serum IGF-I levels were closely related to the disease process in patients with acute cerebral infarction, determination of which was of important clinical values. (authors)

  20. Clinical significance of measurement of changes of serum IGF-II, EGF and CYFRA21-1 levels after chemotherapy in patients with lung cancer

    International Nuclear Information System (INIS)

    Chen Jianlin

    2010-01-01

    Objective: To study the clinical significance of changes of serum IGF-II, EGF and CYFRA21-1 levels after chemotherapy in patients with lung cancer. Methods: Serum IGF-II, EGF (with RIA), and CYFRA21-1 (with ECLIA) levels were determined both before and after chemotherapy in 39 patients with lung cancer as well as once in 35 controls. Results: Before chemotherapy, serum IGF-II, EGF and CYFRA21-1 levels were significantly higher in the patients than those in controls(P<0.01). Six months after chemotherapy, serum IGF-II, EGF and CYFRA21-1 levels dropped markedly, but remained significantly higher than those in controls(P<0.05). Conclusion: The development of lung cancer in patients was closely related to the serum IGF-II, EGF and CYFRA21-1 levels. (authors)

  1. PERFLUORINATED COMPOUNDS (PFCs) IN SERUM OF ...

    Science.gov (United States)

    The PFCs have been used in a wide range of consumer, including residential, products (e.g., stain-resistant coatings for carpets and upholstery). Carbon-fluoride bonds are highly stable, mak-ing PFCs extremely resistant to biodegradation. Thus, PFCs have become globally distributed and are ubiquitously present in serum of wildlife and people. Despite this, comparatively little is known as to how people are primarily exposed, and what (if any) health risk is associated with chronic, low-level exposure. It is hypothesized that house dust may represent a significant exposure route because PFCs can slough or volatilize from products used indoors, subsequently adsorbing to and accumulating within house dust. The purpose of this study was to determine if PFC serum levels in domestic cats tended to increase in proportion to time spent indoors and whether analyte patterns reflected that of food sources [e.g., fish products with high perfluoro-octane sulfonate (PFOS) but low perfluorohexanesulfonate (PFHxS)] or with house dust (PFOS + PFHxS + perfluorooctanoate (PFOA) ─ with high PFHxS levels in the most contaminated dust). In 2008, serum was obtained from feral and pet cats presenting to shelters and clinics in the Raleigh, NC area, including the NCSU VTH. PFC serum levels were measured using high-resolution time-of-flight mass spectroscopy. Data on housing status was available for 50 cats. From least to greatest indoor residential exposure, cats were grouped as

  2. Evaluation of four commercial biuret reagent kits of serum total protein by the American Association for Clinical Chemistry reference measurement procedure.

    Science.gov (United States)

    He, Meilin; Zhang, Jie

    2011-06-01

    In China, the traceability of clinical chemistry methods is still immature. Therefore, it is necessary to establish a reference measurement procedure and evaluate commercial reagent kits using such established procedures. We reproduced the reference measurement procedure for serum total protein, as recommended by the American Association for Clinical Chemistry (AACC). We evaluated the performance by Clinical Laboratory Standard Institute (CLSI) guidelines EP15-A and EP6-A. Subsequently, four commercial reagent kits were evaluated by the reproduced reference procedure following CLSI guideline EP9-A2. The performance of the reproduced reference procedure was as follows: CVs ranged from 0.47% to 0.85% at medical decision levels (X(c)) of 45 g/L, 60 g/L and 80 g/L. Linearity was Y=1.0022X-0.2121 (r=0.9999), and recovery ranged from 100.2% to 102.4%. The External Quality Assessment Scheme for Reference Laboratories in Laboratory Medicine (RELA) was applied, and the result was within the limit of equivalence. The linear relationships of four commercial reagent kits, Merit Choice, KHB, Leadman, and Olympus, were, respectively: Y=0.9922X+0.5776 (r=0.9961); Y=0.9936X+0.4316 (r=0.9992); Y=0.9949X+0.9129 (r=0.9987) and Y=0.9923X+0.8876 (r=0.9989). KHB showed slight negative bias, and the mean±SD was -0.03±0.60 g/L. Merit Choice, Leadman, and Olympus all showed positive bias, and the mean±SDs were 0.02±0.63 g/L, 0.55±0.77 g/L and 0.34±0.71 g/L, respectively. The correlation and bias of four commercial reagent kits for serum total protein were found to be acceptable. Thus, these reagent kits can be used reliably in China.

  3. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.

    Science.gov (United States)

    Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L

    2017-09-01

    C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision assay precision ELISA demonstrated a significant correlation with RIA (R

  4. Antimicrobial and cell viability measurement of bovine serum albumin capped silver nanoparticles (Ag/BSA) loaded collagen immobilized poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) film.

    Science.gov (United States)

    Bakare, Rotimi; Hawthrone, Samantha; Vails, Carmen; Gugssa, Ayele; Karim, Alamgir; Stubbs, John; Raghavan, Dharmaraj

    2016-03-01

    Bacterial infection of orthopedic devices has been a major concern in joint replacement procedures. Therefore, this study is aimed at formulating collagen immobilized poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) film loaded with bovine serum albumin capped silver nanoparticles (Ag/BSA NPs) to inhibit bacterial growth while retaining/promoting osteoblast cells viability. The nanoparticles loaded collagen immobilized PHBV film was characterized for its composition by X-ray Photoelectron Spectroscopy and Anodic Stripping Voltammetry. The extent of loading of Ag/BSA NPs on collagen immobilized PHBV film was found to depend on the chemistry of the functionalized PHBV film and the concentration of Ag/BSA NPs solution used for loading nanoparticles. Our results showed that more Ag/BSA NPs were loaded on higher molecular weight collagen immobilized PHEMA-g-PHBV film. Maximum loading of Ag/BSA NPs on collagen immobilized PHBV film was observed when 16ppm solution was used for adsorption studies. Colony forming unit and optical density measurements showed broad antimicrobial activity towards Escherichia coli, Staphylococcus aureus, and Pseudomonas aeruginosa at significantly lower concentration i.e., 0.19 and 0.31μg/disc, compared to gentamicin and sulfamethoxazole trimethoprim while MTT assay showed that released nanoparticles from Ag/BSA NPs loaded collagen immobilized PHBV film has no impact on MCTC3-E1 cells viability. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Adipokine serum concentrations, anthropometric measurements and socio-economic status in two ethnic groups with different prevalence levels for cardiovascular diseases and type 2 diabetes.

    Science.gov (United States)

    Waisberg, R; Paiker, J E; Crowther, N J

    2011-08-01

    Obesity is more common in African than Asian-Indian populations and yet type 2 diabetes and cardiovascular diseases are more common in the latter populations. The main purpose of the current study was therefore to determine whether ethnic differences in body fat distribution, adipokine levels, and socio-economic status may explain population differences in the prevalence of these metabolic disorders. Leptin, IL-6, CRP, visceral fat, education level, and socio-economic status were measured in 50 African and the same number of Indian women residing in Johannesburg, South Africa. Serum leptin levels were significantly higher in Indian than African subjects (41.3±2.0 and 34.2±2.9 ng/ml, respectively; pAfrican group, (5.22±0.86 vs. 2.54±0.52 pg/ml; peconomic status (pAfrican subjects, however, adjusting for these variables in ANCOVA did not attenuate differences in adipokine or visceral fat levels. We hypothesise that one of the reasons for the higher prevalence of obesity in the African than Indian population may be related to lower leptin levels, whilst ethnic differences in the prevalence of metabolic disorders cannot be explained by differences in adipokine levels, but maybe related to higher visceral adiposity in the Indian group. Georg Thieme Verlag KG Stuttgart · NewYork.

  6. Image Information Obtained Using a Charge-Coupled Device (CCD) Camera During an Immersion Liquid Evaporation Process for Measuring the Refractive Index of Solid Particles.

    Science.gov (United States)

    Niskanen, Ilpo; Sutinen, Veijo; Thungström, Göran; Räty, Jukka

    2018-06-01

    The refractive index is a fundamental physical property of a medium, which can be used for the identification and purity issues of all media. Here we describe a refractive index measurement technique to determine simultaneously the refractive index of different solid particles by monitoring the transmittance of light from a suspension using a charge-coupled device (CCD) camera. An important feature of the measurement is the liquid evaporation process for the refractive index matching of the solid particle and the immersion liquid; this was realized by using a pair of volatile and non-volatile immersion liquids. In this study, refractive indices of calcium fluoride (CaF 2 ) and barium fluoride (BaF 2 ) were determined using the proposed method.

  7. Prediction of Mobility Limitations after Hospitalization in Older Medical Patients by Simple Measures of Physical Performance Obtained at Admission to the Emergency Department

    DEFF Research Database (Denmark)

    Bodilsen, Ann Christine; Hedegaard Klausen, Henrik; Petersen, Janne

    2016-01-01

    Objective: Mobility limitations relate to dependency in older adults. Identification of older patients with mobility limitations after hospital discharge may help stratify treatment and could potentially counteract dependency seen in older adults after hospitalization. We investigated the ability...... of four physical performance measures administered at hospital admission to identify older medical patients who manifest mobility limitations 30 days after discharge. Design: Prospective cohort study of patients (≥65 years) admitted to the emergency department for acute medical illness. During the first...... included. Of those, 128 (40%) patients had mobility limitations at follow-up. Univariate analyzes showed that each of the physical performance measures was strongly associated with mobility limitations at follow-up (handgrip strength(women), OR 0.86 (0.81–0.91), handgrip strength(men), OR 0.90 (0...

  8. Correlation of results obtained by in-vivo optical spectroscopy with measured blood oxygen saturation using a positive linear regression fit

    Science.gov (United States)

    McCormick, Patrick W.; Lewis, Gary D.; Dujovny, Manuel; Ausman, James I.; Stewart, Mick; Widman, Ronald A.

    1992-05-01

    Near infrared light generated by specialized instrumentation was passed through artificially oxygenated human blood during simultaneous sampling by a co-oximeter. Characteristic absorption spectra were analyzed to calculate the ratio of oxygenated to reduced hemoglobin. A positive linear regression fit between diffuse transmission oximetry and measured blood oxygenation over the range 23% to 99% (r2 equals .98, p signal was observed in the patient over time. The procedure was able to be performed clinically without difficulty; rSO2 values recorded continuously demonstrate the usefulness of the technique. Using the same instrumentation, arterial input and cerebral response functions, generated by IV tracer bolus, were deconvoluted to measure mean cerebral transit time. Date collected over time provided a sensitive index of changes in cerebral blood flow as a result of therapeutic maneuvers.

  9. Possible experiment with two counter-orbiting drag-free satellites to obtain a new test of Einstein's general theory of relativity and improved measurements in geodesy

    International Nuclear Information System (INIS)

    Van Patten, R.A.; Everitt, C.W.F.

    1976-01-01

    In 1918, Lense and Thirring calculated that a moon orbiting a rotating planet would experience a nodal dragging effect due to general relativity. We describe an experiment to measure this effect to 1% with two counter-orbiting drag-free satellites in polar earth orbit. In addition to tracking data from existing ground stations, satellite-to-satellite Doppler ranging data are taken near the poles. New geophysical information is inherent in the polar data

  10. Obtainment of the subcritical reactivity by mean of measurement of APSD and CPSD employing pulse mode detectors in the IPEN/MB-01 reactor

    International Nuclear Information System (INIS)

    Lee, Seung Min

    2014-01-01

    This work presents a new experimental approach to determine the reactivity levels of subcritical systems. The method employs the subcritical kinetic model developed by Gandini and Salvatores and it is based only on measured quantities such as counting rates of the detectors employed in the experiments and the parameters arising from the least squares fitting of the APSD (Auto Power Spectral Density) and CPSD (Cross Power Spectral Density). Detector efficiencies, quantity required in other procedures such as Neutron Source Multiplication (NSM) method, are not needed in the proposed method. The only hypothesis made in the method was the independence of the effective delayed neutron fraction and the prompt neutron generation time to the subcriticality level of the system. The proposed method was applied to measure the reactivity of several subcritical configurations of the IPEN/MB-01 reactor. Measurements of APSD and CPSD were performed in several degrees of subcriticality (up to around -7000 pcm). The spectral densities data were least squares fitted to get the prompt decay mode (α) and other quantities. Beside the startup source of the facility, an external neutron source of Am-Be was installed near the core in order to improve neutron counting statistics. The final experimental results are of good quality. The proposed experimental method shows clearly that the classical point kinetic theory cannot describe the measured reactivity. Instead, the reactivity inferred from this model follows closely the subcriticality index (ζ) for the source arrangements in the experiment. The agreement of the MCNP5 and GPT-TORT results, both with ENDF/B-VII.0 as the basic nuclear data library, when compared to the corresponding experimental ones was also good. (author)

  11. Cross section of α-induced reactions on iridium isotopes obtained from thick target yield measurement for the astrophysical γ process

    Directory of Open Access Journals (Sweden)

    T. Szücs

    2018-01-01

    Full Text Available The stellar reaction rates of radiative α-capture reactions on heavy isotopes are of crucial importance for the γ process network calculations. These rates are usually derived from statistical model calculations, which need to be validated, but the experimental database is very scarce. This paper presents the results of α-induced reaction cross section measurements on iridium isotopes carried out at first close to the astrophysically relevant energy region. Thick target yields of 191Ir(α,γ195Au, 191Ir(α,n194Au, 193Ir(α,n196mAu, 193Ir(α,n196Au reactions have been measured with the activation technique between Eα=13.4 MeV and 17 MeV. For the first time the thick target yield was determined with X-ray counting. This led to a previously unprecedented sensitivity. From the measured thick target yields, reaction cross sections are derived and compared with statistical model calculations. The recently suggested energy-dependent modification of the α+nucleus optical potential gives a good description of the experimental data.

  12. Fasting serum blood measures of bone and lipid metabolism in children with myelomeningocele for early detection of cardiovascular and bone fragility risk factors.

    Science.gov (United States)

    Van Speybroeck, Alexander; Mueske, Nicole M; Mittelman, Steven D; Kremer, Richard K; Ryan, Deirdre D; Wren, Tishya A L

    2017-03-01

    This study examined serum levels in children with myelomeningocele to identify the prevalence of pre-clinical signs of disease. A prospective, cross-sectional study. Patients were actively recruited from multidisciplinary care clinics at tertiary children's hospitals from 2010-2012. The control comparison group was recruited by word-of-mouth. Twenty-eight children with myelomeningocele (93% Hispanic; 17 males; 10.0 ± 2.1 years) and 58 controls (84% Hispanic; 30 males; 10.4 ± 2.4 years) provided ≥ 8-hour fasting blood samples with concomitant dual-energy x-ray absorptiometry measurements of body fat. Not applicable. The serum analysis included a lipid panel (cholesterol, triglycerides, high-density lipoprotein, low-density lipoprotein), insulin, glucose, leptin, aspartate aminotransferase, alanine transaminase, alkaline phosphatase, albumin, creatinine, calcium, phosphatase, parathyroid hormone, and vitamin D. Children with myelomeningocele had higher body fat (35.2% versus 29.9%, p=0.01) and altered lipid profiles (lower high-density lipoprotein levels, 43.9 mg/dL versus 51.6 mg/dL, P = 0.03) suggesting elevated risk of metabolic syndrome. They also had a higher prevalence of vitamin D deficiency (43% versus 17%, p=0.02) and significantly lower levels of calcium (9.4 mg/dL versus 9.7 mg/dL, P = 0.003) and alkaline phosphatase (187.0 U/L versus 237.0 U/L, P = 0.003). Unexpectedly children with myelomeningocele had lower parathyroid hormone levels (14.5 pg/mL versus 18.4 pg/mL, P = 0.02) than controls despite lower calcium, vitamin D and alkaline phosphatase levels. This suggests an alteration in the sensing mechanism or response of the parathyroid gland to normal physiological stimuli in patients with myelomeningocele. Children with myelomeningocele have abnormal biochemical markers for cardiovascular disease, insulin resistance and bone and mineral metabolism. Early recognition and monitoring of these risk factors in patients with

  13. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  14. Comparison of concentrations in the environment assessed by the GRNC modelling with those obtained by measurements. Report by the steering committee. December 2009

    International Nuclear Information System (INIS)

    2009-01-01

    Within the frame of a mission assigned to the North Cotentin Radio-Ecology Group (Groupe Radioecologie Nord Cotentin, GRNC) to study the health and environmental impact of chemical releases of the nuclear installations located in the North Cotentin area, this document reports the implementation of a sampling and chemical measurement program, the results of which are used to validate the GRNC modelling for the determination of concentrations of some elements and chemical products in different media: soils, grass, fruits, and milk on the ground side, and seawater, fishes, shellfishes, limpets, and sea sediments as far as the marine environment is concerned

  15. The Changes of Serum TSH in Various States of Thyroid Function

    International Nuclear Information System (INIS)

    Ro, Heung Kyu

    1975-01-01

    The serum concentrations of thyrotropin (TSH) were measured by means of radioimmunoassay, in 98 cases of normal controls, 51 cases of hyperthyroidism, 80 cases of primary hypothyroidism and 4 cases of secondary hypothyroidism to evaluate the diagnostic significance in various functional states of the thyroid. The obtained data were analyzed in correlation with other thyroid function test values in various phases of the functional thyroid diseases. The results were as follows: 1) The serum TSH concentration in normal control group was (1.3-8.0 μU/ml). 2) The measurement of serum TSH was more significant in diagnostic accuracy compared with that of serum T 4 (75.0±12.2%). Free T-4 Index (64.2±15.2%), serum T 3 (41.0±21.0%) or T 3 resin uptake (41.1±15.8%) in evaluation of primary hypothyroidism. 3) In case of overt hypothyroidism, the serum TSH and T 4 were both abnormal, compatible with the clinical diagnosis, while in case of preclinical or mild hypothyroidism, the serum T 4 (41.2±23.8% or 50.0±25.0%) was much less reliable than serum TSH. 4) In the treatment of primary hypothyroidism with desiccated thyroid, the administration of 1 grain of the hormone per day was sufficient to suppress the serum concentration of TSH to normal range. It showed that the measurement of serum TSH concentration was a significant criteria in evaluating the efficiency of the treatment of hypothyroidism. 5) The measurement of serum TSH concentration is a very significant method in the early detection of hypothyroidism induced during or after the treatment of the hyperthyroidism with antithyroid drugs or radioactive Iodine ( 131 I).

  16. Clinical significance of measurement of serum IL-8, IL-1β and TNF-α levels after treatment in patients with periodontitis

    International Nuclear Information System (INIS)

    Wang Tongwu

    2009-01-01

    Objective: To explore the significance of changes of serum IL-8, IL-1β and TNF-α levels after treatment in patients with periodontitis. Methods: Serum IL-8, IL-1β and TNF-α(with RIA) levels were determined in 36 patients with periodontitis both before and after treatment as well as in 35 controls. Results: Before treatment, serum IL-8, IL-1β and TNF-α levels were significantly higher in the patients than those in controls (P 0.05). Conclusion: Detection of serum IL-8, IL-1β and TNF-α levels might reflect the progress of disease in patients with periodontitis and might be of important clinical value. (authors)

  17. Clinical significance of measurement of serum hs-CRP, TNF-α and M-CSF levels after treatment in patients with periodontitis

    International Nuclear Information System (INIS)

    Zhang Yunming

    2007-01-01

    Objective: To explore the significance of changes of serum hs-CRP, TNF-α and M-CSF levels after treatment in patients with periodontitis. Methods: Serum TNF-α, M-CSF (with RIA), hs-CRP (with immuneturbitity method) levels were determined in 38 patients with periodontitis both before and after treatment as well as in 35 controls. Results: Before treatment, the serum hs-CRP, TNF-α and M-CSF levels were significantly higher in the patients than those in controls (P 0.05). Conclusion: Detection of serum hs-CRP, TNF-α and M-CSF levels might reflect the progress of disease in patients with periodontitis. (authors)

  18. Clinical significance of measurement of changes of serum IL-2, IL-4 and IFN-γ levels after treatment in patients with vitiligo

    International Nuclear Information System (INIS)

    Cheng Junmin; Zhou Xiujuan; Zhang Yuhong

    2010-01-01

    Objective: To explore the changes of serum IL-2, IL-4 and IFN-γ levels after treatment in patients with vitiligo. Methods: Serum IL-2 (with RIA) IL-4, IFN-γ (with ELISA) levels were examined in 37 patients with vitiligo both before and after treatment as well as in 35 controls. Results: Before treatment, serum IL-2 levels in the patients were significantly lower than those in controls (P < 0.01), while the serum IL-4, IFN-γ levels were significantly higher (P < 0.01). After treatment for 6 months, the values were greatly corrected, but remained significantly different from those in controls (P < 0.05). Conclusion: Vitiligo is a kind of auto-immune diseases with abnormal immuno-regulation. (authors)

  19. Clinical significance of measurement of changes of plasma ET-1 and serum TGF-β1, urinary microalbuminuria (MAU) levels in patients with type II diabetes

    International Nuclear Information System (INIS)

    Feng Liming; Xu Shan

    2010-01-01

    Objective: To study the clinical significance of changes of plasma ET-1 and serum TGF-β 1 , urinary microalbuminuria levels in patients with type II diabetes. Methods: Plasma ET-1 (with RIA) serum TGF-β 1 (with ELISA)microalbuminuria (with immune method) levels were determination in 40 cases of DM2 without nephropathy, 32 cases of DM2 with nephropathy and 35 controls. Results: The plasma ET-1, serum TGF-β 1