WorldWideScience

Sample records for serum highly sensitive

  1. Resting serum concentration of high-sensitivity C-reactive protein ...

    African Journals Online (AJOL)

    Resting serum concentration of high-sensitivity C-reactive protein (hs-CRP) in sportsmen and untrained male adults. F.A. Niyi-Odumosu, O. A. Bello, S.A. Biliaminu, B.V. Owoyele, T.O. Abu, O.L. Dominic ...

  2. Association of serum uric acid with high-sensitivity C-reactive protein in postmenopausal women.

    Science.gov (United States)

    Raeisi, A; Ostovar, A; Vahdat, K; Rezaei, P; Darabi, H; Moshtaghi, D; Nabipour, I

    2017-02-01

    To explore the independent correlation between serum uric acid and low-grade inflammation (measured by high-sensitivity C-reactive protein, hs-CRP) in postmenopausal women. A total of 378 healthy Iranian postmenopausal women were randomly selected in a population-based study. Circulating hs-CRP levels were measured by highly specific enzyme-linked immunosorbent assay method and an enzymatic calorimetric method was used to measure serum levels of uric acid. Pearson correlation coefficient, multiple linear regression and logistic regression models were used to analyze the association between uric acid and hs-CRP levels. A statistically significant correlation was seen between serum levels of uric acid and log-transformed circulating hs-CRP (r = 0.25, p uric acid levels (β = 0.20, p uric acid levels (odds ratio =1.52, 95% confidence interval 1.18-1.96). Higher serum uric acid levels were positively and independently associated with circulating hs-CRP in healthy postmenopausal women.

  3. Evaluation of serum homocysteine, high-sensitivity CRP, and RBC folate in patients with alopecia areata

    Directory of Open Access Journals (Sweden)

    Maryam Yousefi

    2014-01-01

    Full Text Available Introduction: Alopecia areata (AA is a common type of hair loss with an autoimmune basis. As the role of homocysteine (Hcys, folate, and CRP has been considered in some autoimmune diseases. Objectives: To evaluate homocysteine, folate and CRP level in AA. Methods: This study was performed on 29 patients who had AA for at least 6 months affecting more than 20% of scalp, and 32 healthy controls. Levels of serum Hcys, blood high-sensitivity CRP, and RBC folate were measured in all subjects. Results: The mean level of RBC folate was significantly lower in the patient group than that in controls (P < 0.001. Also, the level of RBC folate was significantly lower in patients with extensive forms of disease (alopecia totalis/alopecia universalis in comparison with more localized form (patchy hair loss (P < 0.05. Patients with higher "Severity of Alopecia Total" (SALT score had lower RBC folate, as well. Serum Hcys and blood high-sensitivity CRP levels did not show a significant difference in two groups. Conclusion: Patients with alopecia areata have lower level of RBC folate which is in negative correlation with both severity and extension of AA.

  4. Highly sensitive detection of bovine serum albumin based on the aggregation of triangular silver nanoplates

    Science.gov (United States)

    Zhang, Ling Ling; Ma, Fang Fang; Kuang, Yang Fang; Cheng, Shu; Long, Yun Fei; Xiao, Qiu Guo

    2016-02-01

    A simple, fast and highly sensitive spectrophotometric method for the determination of bovine serum albumin (BSA) has been developed based on the interactions between triangular silver nanoplates (TAgNPs) and BSA in the presence of Britton-Robison buffer solution (BR). Particularly, the wavelength of absorption maximum (λmax) of TAgNPs is red shifted in the presence of BSA together with Britton-Robinson buffer solution (BR, pH = 2.56), and the color of the solution changed from blue to light blue. This may be due to the interactions between BSA molecules on the surface of TAgNPs through electrostatic forces, hydrogen bonds, hydrophobic effects and van der Waals forces at pH 2.56, which leads to the aggregation of TAgNPs. The determination of BSA was achieved by measuring the change of λmax corresponding to localized surface plasmon resonance (LSPR) from UV-visible spectrophotometry. It was found that the shift value in the wavelength of absorption maximum (Δλ, the difference in absorption maxima of the TAgNPs/BSA/BR mixture and the TAgNPs/BR mixture) was proportionate to the concentration of BSA in the range of 1.0 ng mL- 1 to 100.0 ng mL- 1 with the correlation coefficient of r = 0.9969. The detection limit (3 σ/k) for BSA was found to be as low as 0.5 ng mL- 1.

  5. High-sensitivity serum C-reactive protein levels in subjects with or without myocardial infarction or periodontitis.

    Science.gov (United States)

    Persson, G Rutger; Pettersson, Thomas; Ohlsson, Ola; Renvert, Stefan

    2005-03-01

    Serum high-sensitivity C-reactive protein (hsC-rp) is a non-specific marker of inflammation. Elevated hsC-rp levels are found in subjects with cardiovascular diseases (CVDs). Periodontitis may influence hsC-rp levels. To assess periodontal status and hsC-rp serum levels in consecutive subjects hospitalized and diagnosed with acute myocardial infarction (AMI) (n=85) and in a group of carefully matched subjects (gender, age social, ethnic, and smoking habits) without clinical evidence of CVD (n=63). hsC-rp levels, other routine serum values, and clinical periodontal conditions were studied. Subjects with AMI had higher hsC-rp levels than control subjects (pperiodontitis (30% or more sites with>4.0 mm loss of alveolar bone) had serum hsC-rp>1.8 mg/l was 1.5 (95% CI: 1.1-7.3, pperiodontal parameters in an explanatory model to hsC-rp values. Only the serum leucocyte (white blood cell (WBC)) counts were explanatory to hsC-rp values (beta standard coefficient=0.45, t=3.2, pperiodontitis (pperiodontitis in subjects with no evidence of CVD. (3) Periodontal parameters are not explanatory to elevated serum hsC-rp values if serum WBC and low-density lipoprotein counts are included in the regression model. Copyright 2005 Blackwell Munksgaard.

  6. Crevicular Fluid and Serum Concentrations of Progranulin and High Sensitivity CRP in Chronic Periodontitis and Type 2 Diabetes

    Science.gov (United States)

    Priyanka, N.; Kumari, Minal; Kalra, Nitish; Arjun, P.; Naik, Savitha B.; Pradeep, A. R.

    2013-01-01

    Introduction. This study was designed to correlate the serum and gingival crevicular fluid (GCF) levels of progranulin (PGRN) and high sensitivity C-reactive protein (hs CRP) in chronic periodontitis and type 2 diabetes mellitus (DM). Design. PGRN and hs CRP levels were estimated in 3 groups: healthy, chronic periodontitis, and type 2 DM with chronic periodontitis. Results. The mean PGRN and hs CRP concentrations in serum and GCF were the highest for group 3 followed by group 2 and the least in group 1. Conclusion. PGRN and hs CRP may be biomarkers of the inflammatory response in type 2 DM and chronic periodontitis. PMID:24191130

  7. Crevicular Fluid and Serum Concentrations of Progranulin and High Sensitivity CRP in Chronic Periodontitis and Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    N. Priyanka

    2013-01-01

    Full Text Available Introduction. This study was designed to correlate the serum and gingival crevicular fluid (GCF levels of progranulin (PGRN and high sensitivity C-reactive protein (hs CRP in chronic periodontitis and type 2 diabetes mellitus (DM. Design. PGRN and hs CRP levels were estimated in 3 groups: healthy, chronic periodontitis, and type 2 DM with chronic periodontitis. Results. The mean PGRN and hs CRP concentrations in serum and GCF were the highest for group 3 followed by group 2 and the least in group 1. Conclusion. PGRN and hs CRP may be biomarkers of the inflammatory response in type 2 DM and chronic periodontitis.

  8. The Attainment of High Sensitivity and Precision in Radioimmunoassay Techniques as Exemplified in a Simple Assay of Serum Insulin

    Energy Technology Data Exchange (ETDEWEB)

    Albano, Janet; Ekins, R. P. [Institute of Nuclear Medicine, Middlesex Hospital Medical School, London (United Kingdom)

    1970-02-15

    Recent controversy has underlined the fundamental confusion surrounding the concepts of assay ''sensitivity'' and ''precision'' and, in particular, their optimization in radioimmunoassay and other saturation assay procedures. Many formal definitions of sensitivity (e.g. that laid down by the American Chemical Society) express this concept in terms of the slope of the ''dose'' response curve; nevertheless, in common usage, the term is normally regarded as a synonym for the detection limit of the measurement technique. However, a technique which is ''sensitive'' in the formal sense may not display a low limit of detection, and it is readily demonstrable that, in radioimmunoassay systems in particular, there are circumstances in which increase in the slope of the response curve may lead to an increase in the detection limit of the assay. The authors have based their insulin assay protocols on mathematical principles specifically designed to lead to the minimization of the detection limit. The method depends on the use of (uncoated) charcoal for the separation of free and bound labelled insulin in incubation mixtures in which insulin-free human serum is used as diluent. The detection limit of the method is approximately 1 pg/ml of incubation mixture, corresponding to roughly 0.25 {mu}U/ml of serum at the serum dilutions used. In a formal comparative study, the method has been shown to be more sensitive, precise and accurate than other methods relying on double antibody or chromato-electrophoietic separation. The relevance of such factors as high specific activity labelled hormone to the attainment of high sensitivity is discussed. (author)

  9. Correlation between Serum High Sensitivity CRP Level and Inhospital Cardiac Events in the Patients with Unstable Angina

    Directory of Open Access Journals (Sweden)

    H. Kazerani

    2007-10-01

    Full Text Available Introduction & Objective: Several studies have been performed to evaluate correlation of serum high sensitivity CRP (hs-CRP level with the prognosis of the patients with diagnosis of unstable angina, and by now different results were reported. The aim of this study was to assess correlation between serum hs-CRP level and inhospital prognosis and cardiac events in the patients with unstable angina. Materials & Methods: This descriptive analytic study was performed from Sep 2004 till Feb 2006 in Shahid Beheshti hospital. Kermanshah, Iran. Sera were collected from 250 patients for hs-CRP measurement. Exclusion criteria were: acute ST elevation MI, non ST elevation MI, patients with history of recent infection, patients with recent trauma and patients with serum high sensitive CRP level more than 10 mg/lit. Patients were divided into two groups, first group whose serum hs-CRP level was less than 3 mg/lit and second group whose serum hs-CRP level was between 3 and 10 mg/lit. They were followed for recurrent chest pain, arrhythmias, pulmonary edema, acute myocardial infarction and in hospital death. Results were analyzed using x² and t-test. Results: Mean age were 57±7.8 and 58±11.5 years in first group and second group respectively. There was statistically significant difference in some cardiac complications such as dyspnea, duration of hospitalization, recurrent chest pain, CCU admission (p<0.001 and in hospital myocardial infarction (p=0.03, between two groups. Some complications did not have significant difference such as pulmonary edema, cardiogenic shock, arrhythmia, S3, S4 and pulmonary rates .There was no mortality in both groups. Conclusion: According to the results, we can use serum hs-CRP level for risk stratification in the patients with diagnosis of unstable angina. Obviously the patients with high serum hs-CRP level need more attention whether early invasive management help these patients, may be the matter of later studies.

  10. Serum high sensitivity C-reactive protein levels and the severity of coronary atherosclerosis assessed by angiographic gensini score

    International Nuclear Information System (INIS)

    Masood, A.; Jafar, S.S.; Akram, Z.

    2011-01-01

    Objective: To assess the relationship between plasma high sensitivity C-reactive protein levels with severity of coronary atherosclerosis. Materials and Methods: The study included 80 patients subjected to coronary angiography. The extent of Coronary Artery Disease (CAD) was assessed using Gensini score. Patients were divided into three risk groups according to hs-CRP levels ( 3mg/L- as high risk). Mean Angiographic Gensini scores were compared among the risk groups. Correlation between serum hs-CRP levels and angiographic Gensini scores was also assessed. Results: The 26 (32.5%) patients belonging to hs-CRP low-risk group had a mean angiographic Gensini score of 11.8 +- 5.8, 18 (22.5%) belonging to moderate-risk group had a mean score of 28.9 +- 7.9 and 36 (45%) belonging to high- risk group had a mean score of 78.7 +- 41.0. By applying ANOVA the mean angiographic Gensini scores showed increasing trend from lower to higher hs-CRP risk groups (p < 0.001). Serum hs-CRP levels showed significant correlation with respective angiographic Gensini scores by Pearson's correlation (p < 0.001). Conclusion: Serum hs-CRP levels show significant correlation with the severity of Coronary Artery Disease as assessed by angiographic Gensini score. (author)

  11. Application of MoS{sub 2} modified screen-printed electrodes for highly sensitive detection of bovine serum albumin

    Energy Technology Data Exchange (ETDEWEB)

    Kukkar, Manil [Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030 (India); Academy of Scientific and Innovative Research, CSIR-CSIO, Sector 30-C, Chandigarh, 160030 (India); Sharma, Ashish [Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030 (India); UIET, Panjab University, Sector 14, Chandigarh, 160014 (India); Kumar, Parveen [Department of Biotechnology, Kurukshetra University, Kurukshetra, 136119 (India); Kim, Ki-Hyun, E-mail: kkim61@hanyang.ac.kr [Department of Civil & Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763 (Korea, Republic of); Deep, Akash, E-mail: dr.akashdeep@csio.res.in [Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030 (India); Academy of Scientific and Innovative Research, CSIR-CSIO, Sector 30-C, Chandigarh, 160030 (India)

    2016-10-05

    The present work reports the application of a new molybdenum disulphide (MoS{sub 2})-based electrochemical platform for highly sensitive quantitation of an iron-binding protein, bovine serum albumin (BSA). The gold screen-printed electrodes were modified with MoS{sub 2} nanoflakes, followed by bioconjugation with anti-BSA antibodies. Using the above bioelectrode, cyclic voltammetric analysis was carried out in the presence of a Fe{sup 3+}/Fe{sup 2+} redox probe which exhibited a linear response of peak current with varying concentrations of BSA up to 10 ng/mL (with a detection limit of 0.006 ng/mL). This study is novel in that it shows a considerable enhancement of signal during electrochemical sensing of a protein. - Highlights: • MoS{sub 2} nanoflakes have been used for an electrochemical immunosensor. • The sensor's response was proportional to the antigen concentration. • Highly sensitive and specific detection of iron-binding protein ‘BSA’ is achieved. • A wide linear range of detection of BSA is demonstrated.

  12. Association between serum levels of high sensitive C-reactive protein and inflammation activity in chronic gastritis patients.

    Science.gov (United States)

    Rahmani, Asghar; Moradkhani, Atefeh; Hafezi Ahmadi, Mohammad Reza; Jafari Heirdarlo, Ali; Abangah, Ghobad; Asadollahi, Khairollah; Sayehmiri, Kourosh

    2016-01-01

    Gastritis is an important premalignant lesion and recent studies suggested a production of inflammatory cytokine-like C-reactive protein during gastritis. This study aimed to determine any relationship between high sensitive C-reactive protein (hs-CRP) and inflammation activity among patients with gastritis. Demographic and clinical variables of participants were collected by a validated questionnaire. Using histology of the gastric mucosa, Helicobacter pylori status was investigated and serum concentrations of hs-CRP were measured among dyspeptic patients. Correlation between hs-CRP serum levels and inflammation activities was evaluated by logistic regression analysis. The relation between active inflammation and other variables was evaluated by logic link function model. Totally 239 patients (56.6% female) were analysed. The prevalence of mild, moderate and severe inflammation activities was 66.5%, 23.8% and 9.6% respectively. Mean ± SD of hs-CRP among men and women were 2.85 ± 2.84 mg/dl and 2.80 ± 4.80 mg/dl (p = 0.047) respectively. Mean ± SD of hs-CRP among patients with H. pylori infection, gland atrophy, metaplasia and dysplasia were 2.83 ± 3.80 mg/dl, 3.52 ± 5.1 mg/dl, 2.22 ± 2.3 mg/dl and 5.3 ± 5.04 mg/dl respectively. Relationship between hs-CRP and inflammation activities (p gastritis, elevated hs-CRP levels may be considered as a predictive marker of changes in gastric mucosa and a promising therapeutic target for patients with gastritis.

  13. Effect of a high monounsaturated fatty acids diet and a Mediterranean diet on serum lipids and insulin sensitivity in adults with mild abdominal obesity

    NARCIS (Netherlands)

    Bos, M.B.; Vries, de J.H.M.; Feskens, E.J.M.; Dijk, van S.J.; Hoelen, D.; Siebelink, E.; Heijligenberg, R.; Groot, de C.P.G.M.

    2010-01-01

    Background and aims - Diets high in monounsaturated fatty acids (MUFA) such as a Mediterranean diet may reduce the risk of cardiovascular diseases by improving insulin sensitivity and serum lipids. Besides being high in MUFA, a Mediterranean diet also contains abundant plant foods, moderate wine and

  14. Association of Progranulin and High Sensitivity CRP Concentrations in Gingival Crevicular Fluid and Serum in Chronic Periodontitis Subjects with and without Obesity

    Directory of Open Access Journals (Sweden)

    A. R. Pradeep

    2012-01-01

    Full Text Available Background: Obesity is considered as a strong risk factor of inflammatory periodontal tissue destruction. The purpose of this study is to determine presence of progranulin (PGRN and high sensitivity C reactive protein (hs CRP levels in serum and gingival crevicular fluid (GCF in obese subjects with chronic periodontitis and to find an association, if any.

  15. A highly selective and sensitive Tb3+-acetylacetone photo probe for the assessment of acetazolamide in pharmaceutical and serum samples

    Science.gov (United States)

    Youssef, A. O.

    2018-04-01

    A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.

  16. Highly selective and sensitive detection of Cu2+ with lysine enhancing bovine serum albumin modified-carbon dots fluorescent probe.

    Science.gov (United States)

    Liu, Jia-Ming; Lin, Li-ping; Wang, Xin-Xing; Lin, Shao-Qin; Cai, Wen-Lian; Zhang, Li-Hong; Zheng, Zhi-Yong

    2012-06-07

    Based on the ability of lysine (Lys) to enhance the fluorescence intensity of bovine serum albumin modified-carbon dots (CDs-BSA) to decrease surface defects and quench fluorescence of the CDs-BSA-Lys system in the presence of Cu(2+) under conditions of phosphate buffer (PBS, pH = 5.0) at 45 °C for 10 min, a sensitive Lys enhancing CDs-BSA fluorescent probe was designed. The environment-friendly, simple, rapid, selective and sensitive fluorescent probe has been utilized to detect Cu(2+) in hair and tap water samples and it achieved consistent results with those obtained by inductively coupled plasma mass spectroscopy (ICP-MS). The mechanism of the proposed assay for the detection of Cu(2+) is discussed.

  17. Effect of Atorvastatin on Serum Levels of Total Cholesterol and High-Sensitivity C-reactive Protein in High-Risk Patients with Atrial Fibrillation in Asia.

    Science.gov (United States)

    Shi, Ming Yu; Xue, Feng Hua; Teng, Shi Chao; Jiang, Li; Zhu, Jing; Yin, Feng; Gu, Hong Yue

    2015-08-01

    The aim of this meta-analysis was to investigate the effects of atorvastatin on serum levels of high-sensitivity C-reactive protein (hs-CRP) and total cholesterol in atrial fibrillation (AF) patients in Asia. By searching English and Chinese language-based electronic databases (ie, PubMed, EBSCO, Ovid, SpringerLink, Wiley, Web of Science, Wanfang database, China National Knowledge Infrastructure, and VIP database), we identified 13 studies relevant to our topic of interest. Data were collected from the 13 studies and analyzed with Comprehensive Meta-Analysis software (version 2.0, Biostat Inc., Englewood, New Jersey). Initially, our database searches retrieved 356 studies (45 in English, 311 in Chinese). Thirteen studies were selected for the meta-analysis following stringent criteria. The data included 1239 patients with AF, of whom 634 were treated with atorvastatin and included in the treatment group, and 605 patients were treated with conventional treatment and included in the control group. The results of our meta-analysis suggested that the serum levels of hs-CRP (mg/L) and total cholesterol (mmol/L) in the treatment group were significantly lower than those of the control group (hs-CRP: standardized mean difference = 0.962; 95% CI, 0.629-1.295, P < 0.001; total cholesterol: standardized mean difference = 1.400; 95% CI, 0.653-2.146, P < 0.001). The findings of this study suggest that atorvastatin may be very effective in decreasing serum levels of hs-CRP and total cholesterol to prevent cardiovascular events. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.

  18. Crevicular and serum levels of monocyte chemoattractant protein-4 and high-sensitivity C-reactive protein in periodontal health and disease.

    Science.gov (United States)

    Kumari, Minal; Pradeep, A R; Priyanka, N; Kalra, Nitish; Naik, Savitha B

    2014-06-01

    Chemokines are chemotactic cytokines that are involved in destruction of the periodontal structures. The aim of this study is to determine the presence of MCP-4 and high sensitivity C reactive protein (hsCRP) levels in gingival crevicular fluid (GCF) and serum in periodontal health and disease and to find a correlation between MCP-4 and hsCRP in GCF and serum. 40 subjects (20 males and 20 females) were selected and divided into three groups based on clinical parameters and radiologic parameters: Group 1 (10 healthy); Group 2 (15 gingivitis subjects) and Group 3 (15 chronic periodontitis subjects). The levels of serum and GCF MCP-4 were determined by ELISA and hsCRP levels were determined by immunoturbidimetry method. The mean GCF and serum concentration of MCP-4 were the highest for group 3 followed by group 2 and least in group 1. Similarly, the mean hsCRP concentrations were highest for group 3 and least in group 1. Moreover, a significant positive correlation was found between serum and GCF MCP-4 and hsCRP levels and periodontal parameters. The levels of MCP-4 and hsCRP increased from healthy to periodontitis. It can be proposed that MCP-4 and hsCRP are the potential biomarkers of inflammation in periodontal health and disease. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Clinical diagnostic value of determination of serum lschemia modified albumin, homocysteine and high-sensitivity C-reactive protein levels in patients with acute coronary syndrome

    International Nuclear Information System (INIS)

    Lu Weiqun; Jiang Donglin; Lu Weigu

    2009-01-01

    Objective: To study the clinical diagnostic value of determination of serum ischemia modified albumin (IMA), homocysteine (Hcy) and high-sensitivity C-reactive protein (hs-CRP) levels in patients with acute coronary syndrome (ACS). Methods: Serum IMA (with albumin-cobalt binding assay), Hcy (with ELISA) and hs-CRP (with RIA) levels were determined in 73 patients with ACS within 3 hours after onset of chest pain and 40 controls. Results: The sensitivity of IMA was 87.67%, the specificity was 100%. The area under curve of ROC was 0.985 (95% confidence interval 0.969 ∼ 1.001). All the figures were higher than those of Hcy and hs-CRP. Combined determination of IMA, Hcy and hs-CRP, would increass the sensitivity to 97.26%. Conclusion: IMA is one of the earliest sensitive indicators for clinical diagnosis of early myocardial ischemia in patients with ACS. Combined determination of IMA, Hcy and hs-CRP would be even more sensitive. (authors)

  20. Serum, plasma, and dried blood spot high sensitivity C-reactive protein enzyme immunoassay for population research

    OpenAIRE

    Brindle, Eleanor; Fujita, Masako; Shofer, Jane; O’Connor, Kathleen A.

    2010-01-01

    C-reactive protein (CRP) is used as a biomarker of morbidity and mortality risk in studies of population health, and is essential to interpretation of several micronutrient biomarkers. There is thus need for a robust high sensitivity CRP (hsCRP) measurement method for large-scale, non-clinical studies. We developed an efficient, inexpensive assay suitable for quantifying CRP across the physiological range using any blood specimen type. The ELISA uses readily available monoclonal antibodies to...

  1. Relationship between serum high-sensitivity C-reactive protein and modified TOAST classification as well as OCSP subtypes in patients with acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Hua-jun CHANG

    2014-10-01

    Full Text Available This paper aims to investigate the relationship between serum high-sensitivity C-reactive protein (hs-CRP level and modified TOAST classification as well as OCSP subtypes in patients with acute ischemic stroke. Serum hs-CRP was measured in 240 patients with acute ischemic stroke and 120 normal controls. All patients were classified according to modified TOAST classification and OCSP criteria. Serum hs-CRP levels in acute ischemic stroke group were significantly higher than those in normal control group [(13.68 ± 6.92 mg/L vs (3.98 ± 0.76 mg/L; t = 6.922, P = 0.002]. Among modified TOAST subtypes, the highest serum hs-CRP level was in cardioembolism (CE group [(16.82 ± 6.16 mg/L], followed by arterothrombosis (AT group [(15.17 ± 5.68 mg/L], stroke of undetermined etiology (SUD group [(10.06 ± 3.89 mg/L] and small artery disease (SAD group [(9.86 ± 3.75 mg/L, P = 0.027]. Among OCSP subtypes, the highest serum hs-CRP level was in total anterior circulation infarct (TACI group [(17.02 ± 6.98 mg/L], followed by posterior circulation infarct (POCI group [(15.91 ± 7.12 mg/L], partial anterior circulation infarct (PACI group [(12.83 ± 4.95 mg/L] and lacunar infarct (LACI group [(10.61 ± 5.73 mg/L, P = 0.005]. Serum hs-CRP levels are various in different modified TOAST and OCSP subtypes, which may reflect etiological and pathophysiological diversity of acute ischemic stroke, guide clinical treatment and help to predict prognosis. doi: 10.3969/j.issn.1672-6731.2014.10.013

  2. High sensitive C-reactive protein and serum amyloid A are inversely related to serum bilirubin : effect-modification by metabolic syndrome

    NARCIS (Netherlands)

    Deetman, Petronella E.; Bakker, Stephan J. L.; Dullaart, Robin P. F.

    2013-01-01

    Background: Bilirubin has been implicated in cardiovascular protection by virtue of its anti-inflammatory and anti-oxidative properties. The metabolic syndrome is featured by enhanced low-grade systemic inflammation and oxidative stress. Serum amyloid A (SAA) impairs anti-oxidative properties of

  3. Gold nanoparticle labeling with tyramide signal amplification for highly sensitive detection of alpha fetoprotein in human serum by ICP-MS.

    Science.gov (United States)

    Li, Xiaoting; Chen, Beibei; He, Man; Xiao, Guangyang; Hu, Bin

    2018-01-01

    In this work, we developed an immunoassay based on tyramide signal amplification (TSA) and gold nanoparticles (Au NPs) labeling for highly sensitive detection of alpha fetoprotein (AFP) by inductively coupled plasma mass spectrometry (ICP-MS). AFP was captured by anti-AFP1 coating on the 96-well plate and labeled by anti-AFP2-horseradish peroxidase (HRP), in which the HRP can catalyze the deposition of biotinylated tyramine on the nearby protein. Then the streptavidin (SA)-Au NPs was labeled on the deposited biotinylated tyramine as the intensive signal probe for ICP-MS measurement. Under the optimal experimental conditions, the limit of detection of the developed method for AFP was 1.85pg/mL and the linear range was 0.005-2ng/mL. The relative standard deviation for seven replicate detections of 0.01ng/mL AFP was 5.2%. The proposed method was successfully applied to the detection of AFP in human serum with good recoveries. This strategy is highly sensitive and easy to operate, and can be extended to the sensitive detection of other biomolecules in human serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The effects of wet cupping on serum high-sensitivity C-reactive protein and heat shock protein 27 antibody titers in patients with metabolic syndrome.

    Science.gov (United States)

    Farahmand, Seyed Kazem; Gang, Li Zhi; Saghebi, Seyed Ahmad; Mohammadi, Maryam; Mohammadi, Shabnam; Mohammadi, Ghazaleh; Ferns, Gordan A; Ghanbarzadeh, Majid; Razmgah, Gholamreza Ghayour; Ramazani, Zahra; Ghayour-Mobarhan, Majid; Esmaily, Habibollah; Bahrami Taghanaki, Hamidreza; Azizi, Hoda

    2014-08-01

    It has previously been reported that increased level of serum heat shock proteins (Hsps) antibody in patients with metabolic syndrome. It is possible that the expression of Hsp and inflammatory markers can be affected by cupping and traditional Chinese medicine. There is a little data investigating the effects of cupping on markers of inflammation and Hsp proteins, hence, the objective of this study was evaluation of the effects of wet cupping on serum high-sensitivity C-reactive protein (hs-CRP) and Hsp27 antibody titers in patients with metabolic syndrome. Serum Hs-CRP and Hsp27 antibody titers were assessed in samples from 126 patients with metabolic syndrome (18-65 years of age) at baseline, and after 6 and 12 weeks after treatment. One hundred and twenty-six patients were randomly divided into the experimental group treated with wet cupping combined with dietary advice, and the control group treated with dietary advice alone using a random number table. Eight patients in case group and five subjects in control groups were excluded from the study. Data were analyzed using SPSS 15.0 software and a repeated measure ANCOVA. Serum hs-CRP titers did not change significantly between groups (p>0.05) and times (p=0.27). The same result was found for Hsp27 titers (p>0.05). Wet-cupping on the interscapular region has no effect on serum hs-CRP and Hsp27 patients with metabolic syndrome. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Concentration Study of High Sensitive C - reactive Protein and some Serum Trace Elements in Patients with Benign and Malignant Breast Tumor.

    Science.gov (United States)

    Abdollahi, Alireza; Ali-Bakhshi, Abbas; Farahani, Zahra

    2015-10-01

    Background : Breast cancer is the most common invasive cancer in females worldwide. It accounts for 16% of all female cancers and 22.9% of invasive cancers in women. 18.2% of all cancer deaths worldwide including both males and females are from breast cancer. In this study we compared few serum elements in patients with benign and malignant breast tumor to find any related prognostic and predictive value. A case-control study was carried out in a hospital (Tehran - Iran) in 2012. Target population was divided in 2 groups; subjects with benign and malignant breast tumors. We did preoperative hematological test. Five milliliter fasting blood vein was collected, centrifuged in 3000 g for 15 minutes to obtain serum. We measured serum Calcium (Ca), Phosphorus (P), Magnesium (Mg), Zinc (Zn), and high sensitive-CRP, analyzed statistically and compared recorded elements in 2 groups by software package SPSS version 16. The level of significant was considered P benign and malignant breast disease.

  6. Alteration of serum high-sensitivity C-reactive protein level in gestational diabetes mellitus and correlation with in insulin resistance

    International Nuclear Information System (INIS)

    Zou Gang; Li Cuiyin; Shao Hao; Lu Zeyuan; Lai Liping; Liu Lan; Hu Xiaorong; Ma Jiangtao

    2008-01-01

    Objective: To explore the dynamic of high-sensitivity C-reactive protein (hs-CRP) and its correlation with insulin resistance (IR) during different stages of gestational diabetes mellitus (GDM). Methods: Thirty-two subjects with GDM and thirty-one cases of normal glucose tolerance (NGT) pregnant women were enrolled in the study, fasting insulin (FINS) were determined by radioimmunoassay, the fasting blood glucose (FBG) was measured by using glucose oxidase, immunoturbidimetry performed to evaluate serum hs-CRP levels. Tests repeated for each group according different stages of prenatal 25-28 weeks, 29- 32 weeks, 37-38 weeks and postpartum 6-8 weeks. IR was assessed by the homeostasis model assessment insulin resistance index (HOMA-IR). Results: (1)Serum hs-CRP levels in NGT and GDM had few change with gestational age, but both significantly decreased at postpartum. (2)Serum hs-CRP levels in GDM significantly increased than NGT in the same stage (t was 7.31, 7.78, 6.33, respectively, P<0.01 ). (3) HOMA-IR in GDM significantly increased than NGT in the same gestational stage (t was 31.18, 31.10, 28.39, respectively, P<0.01). (4)Pearson correlation analysis showed that FBG, FINS and hs-CRP had significant association with HOMA-IR (regression coefficient of 0.478, 0.902, 0.293, respectively, P<0.01). Multiple regression analysis identified FINS, FBG and hs-CRP as the factors significantly affecting HOMA-IR (regression coefficient of 0.441, 0.876, 0.261, respectively, P<0.01). Conclusion: Serum hs-CRP levels in GDM had few change with gestational age, but all significantly increased than NGT in the same stage, and which were the most significant factors affecting HOMA-IR. (authors)

  7. Evaluation of a high-sensitivity assay for measurement of canine and feline serum cardiac troponin I

    DEFF Research Database (Denmark)

    Langhorn, Rebecca; Willesen, Jakob; Tarnow, Inge

    2013-01-01

    Cardiac troponins are established as the gold standard biomarkers for acute cardiac injury. As even small elevations of cardiac troponins have prognostic relevance in people, it is important to investigate the performance of sensitive assays for use in veterinary medicine....

  8. Evaluation of Serum Levels of Pregnancy Associated Plasma Protein-A, Tumor Necrosis Factor-alpha and Highly Sensitive C-Reactive Protein in Diabetic Children

    International Nuclear Information System (INIS)

    Abdel-Messeih, PH.L.; El-safie, A.I.; Said, A.I.

    2011-01-01

    Recent evidence favours the primary role of cellular auto immunity and its humoral mediators in the pathogenesis and follow up of children with type 1 diabetes mellitus (type 1 DM). The present study is carried out to investigate serum levels of pregnancy associated plasma protein-A (PAPP-A), tumor necrosis factor-alpha (TNF-alpha ) and highly sensitive C-reactive protein (hs-CRP) in children with type 1 DM. Potential role of body mass index (BMI) was evaluated. Circulating levels of TNF-alpha, PAPP-A and hs-CRP are significantly increased in children with type 1 DM as compared with healthy subjects suggesting activation of inflammatory immune response system. A significant negative correlation was obtained between TNF-alpha and BMI in diabetic patients. This is highly suggestive of the availability of these non invasive indices to help further examining type 1 DM pathophysiology and monitoring pharmacological interventions to interfere with disease development and progression.

  9. The Serum High-Sensitive C Reactive Protein and Homocysteine Levels to Evaluate the Prognosis of Acute Ischemic Stroke

    Directory of Open Access Journals (Sweden)

    Tahir Yoldas

    2007-01-01

    Full Text Available Ischemic stroke is one of the most common causes of death worldwide and is most often caused by thrombotic processes. We investigated the changes in hsCRP and homocysteine levels, two of these risk factors, during the acute period of ischemic stroke and evaluated the relationship between these levels and the short-term prognosis. HsCRP and homocysteine levels were measured at the 2nd, 5th, and 10th days in forty patients admitted within second of an ischemic stroke. The clinical status of the patients was simultaneously evaluated with the Scandinavian stroke scale. The results were compared with 40 healthy control subjects whose age and sex were matched with the patients. The mean hsCRP levels of the patients were 9.4±7.0 mg/L on the 2nd day, 11.0±7.4 mg/L on the 5th day, and 9.2±7.0 mg/L on the 10th day. The mean hsCRP level of the control subjects was 1.7±2.9 mg/L. The mean hsCRP levels of the patients on the 2nd, 5th, and 10th days were significantly higher than the control subjects (P<.001. The patients' mean homocysteine levels were 40.6±9.6μmol/L on the 2nd day, 21.7±11.1μmol/L on the 5th day, and 20.7±9.2μmol/L on the 10th day. The mean homocysteine level of the control subjects was 11.2±1.1μmol/L. The homocysteine levels of the patients were higher than the control subjects at all times (P<.01. In conclusion, patients with stroke have a higher circulating serum hsCRP and homocysteine levels. Short-term unfavorable prognosis seems to be associated with elevated serum hsCRP levels in patients with stroke. Although serum homocysteine was found to be higher, homocysteine seems not related to prog nosis.

  10. Elevated serum high-sensitivity C-reactive protein levels in fibromyalgia syndrome patients correlate with body mass index, interleukin-6, interleukin-8, erythrocyte sedimentation rate.

    Science.gov (United States)

    Xiao, Yangming; Haynes, Wanda L; Michalek, Joel E; Russell, I Jon

    2013-05-01

    The levels of several inflammatory cytokines are abnormal in many patients with the fibromyalgia syndrome (FMS) and may play a role in its pathogenesis. The inflammatory marker C-reactive protein (CRP) is associated with the disease activity in patients with inflammatory rheumatic diseases, but its role in FMS is unknown. We undertook this study to determine whether high-sensitivity CRP (hsCRP) is elevated in FMS and whether its levels relate to key biologic or clinical measures. One hundred and five patients with FMS (1990 ACR criteria) and 61 healthy normal controls (HNC) at a ratio of 2:1 were recruited. The serum concentrations of hsCRP, interleukin-8 (IL-8), and interleukin-6 (IL-6) were assessed using enzyme-linked immunosorbent assays. The hsCRP levels were marginally higher in FMS than in HNC (p = 0.06) and its abnormality rate (>1.5 SD above the HNC mean) was significantly higher in FMS (25 %) compared with HNC (6.8 %) (p = 0.03). Serum IL-8 levels, IL-6 levels, and erythrocyte sedimentation rate (ESR) in FMS did not differ from those in HNC. Body mass index (BMI), ESR, IL-8, and IL-6 levels correlated with hsCRP levels in FMS. No associations were found between hsCRP and age, gender, ethnicity, or other clinical measures. Serum CRP levels were higher in FMS and significantly correlated with BMI, ESR, IL-8, and IL-6 levels, suggesting that inflammation may contribute to the symptoms in some FMS patients, particularly those who are obese. Weight loss and therapies directed against inflammation may be useful in the management of FMS patients with elevated hsCRP.

  11. Association of Serum Ceruloplasmin Level with Obesity: Some Components of Metabolic Syndrome and High-Sensitive C-Reactive Protein in Iran

    Directory of Open Access Journals (Sweden)

    Seyyed Morteza Safavi

    2012-01-01

    Full Text Available Background. One of the mechanisms that has been suggested for obesity related metabolic disturbances is obesity-induced inflammation. Pro-inflammatory cytokines generated in adipose tissue can increase hepatic synthesis of inflammation-sensitive plasma proteins (ISPs including ceruloplasmin (Cp. In this study we aimed to investigate the relation between serum Cp level and obesity. Methods. 61 persons with body mass index (BMI ≥ 25 kg/m2 (case group and 61 persons with BMI < 25 kg/m2 (control group were included in this study with a case-control design. Serum Cp levels, triglyceride level, fating blood glucose, total cholesterol, LDL-cholesterol, HDL-cholesterol and hsCRP were measured in both groups. Results. We did not observe any significant association between serum Cp level and BMI in all subjects [OR: 1.02 (CI, 0.967 to 1.07] and in case (β=0.012, P=0.86 and control groups (β=0.49, P=0.07 separately. However, in control group, this positive association was marginally significant. We found a positive correlation between serum Cp level and serum triglyceride level. Conclusion. Serum Cp level was not related to obesity in this group of subjects. None of the baseline variables could predict obesity in this group of subjects, including serum Cp level, FBS, total cholesterol, LDL and HDL- cholesterols and hsCRP.

  12. Utility of the combination of serum highly-sensitive C-reactive protein level at discharge and a risk index in predicting readmission for acute exacerbation of COPD,

    Directory of Open Access Journals (Sweden)

    Chun Chang

    2014-10-01

    Full Text Available OBJECTIVE: Frequent readmissions for acute exacerbations of COPD (AECOPD are an independent risk factor for increased mortality and use of health-care resources. Disease severity and C-reactive protein (CRP level are validated predictors of long-term prognosis in such patients. This study investigated the utility of combining serum CRP level with the Global Initiative for Chronic Obstructive Lung Disease (GOLD exacerbation risk classification for predicting readmission for AECOPD. METHODS: This was a prospective observational study of consecutive patients hospitalized for AECOPD at Peking University Third Hospital, in Beijing, China. We assessed patient age; gender; smoking status and history (pack-years; lung function; AECOPD frequency during the last year; quality of life; GOLD risk category (A-D; D indicating the greatest risk; and serum level of high-sensitivity CRP at discharge (hsCRP-D. RESULTS: The final sample comprised 135 patients. Of those, 71 (52.6% were readmitted at least once during the 12-month follow-up period. The median (interquartile time to readmission was 78 days (42-178 days. Multivariate analysis revealed that serum hsCRP-D ≥ 3 mg/L and GOLD category D were independent predictors of readmission (hazard ratio = 3.486; 95% CI: 1.968-6.175; p < 0.001 and hazard ratio = 2.201; 95% CI: 1.342-3.610; p = 0.002, respectively. The ordering of the factor combinations by cumulative readmission risk, from highest to lowest, was as follows: hsCRP-D ≥ 3 mg/L and GOLD category D; hsCRP-D ≥ 3 mg/L and GOLD categories A-C; hsCRP-D < 3 mg/L and GOLD category D; hsCRP-D < 3 mg/L and GOLD categories A-C. CONCLUSIONS: Serum hsCRP-D and GOLD classification are independent predictors of readmission for AECOPD, and their predictive value increases when they are used in combination.

  13. Vitamin D supplementation affects serum high-sensitivity C-reactive protein, insulin resistance, and biomarkers of oxidative stress in pregnant women.

    Science.gov (United States)

    Asemi, Zatollah; Samimi, Mansooreh; Tabassi, Zohreh; Shakeri, Hossein; Esmaillzadeh, Ahmad

    2013-09-01

    Unfavorable metabolic profiles and oxidative stress in pregnancy are associated with several complications. This study was conducted to determine the effects of vitamin D supplementation on serum concentrations of high-sensitivity C-reactive protein (hs-CRP), metabolic profiles, and biomarkers of oxidative stress in healthy pregnant women. This randomized, double-blind, placebo-controlled clinical trial was conducted in 48 pregnant women aged 18-40 y old at 25 wk of gestation. Participants were randomly assigned to receive either 400 IU/d cholecalciferol supplements (n = 24) or placebo (n = 24) for 9 wk. Fasting blood samples were taken at study baseline and after 9 wk of intervention to quantify serum concentrations of hs-CRP, lipid concentrations, insulin, and biomarkers of oxidative stress. After 9 wk of intervention, the increases in serum 25-hydroxyvitamin D and calcium concentrations were greater in the vitamin D group (+3.7 μg/L and +0.20 mg/dL, respectively) than in the placebo group (-1.2 μg/L and -0.12 mg/dL, respectively; P insulin concentrations (vitamin D vs. placebo groups: -1.0 vs. +2.6 μIU/mL; P-interaction = 0.04) and a significant increase in the Quantitative Insulin Sensitivity Check Index score (vitamin D vs. placebo groups: +0.02 vs. -0.02; P-interaction = 0.006), plasma total antioxidant capacity (vitamin D vs. placebo groups: +152 vs. -20 mmol/L; P-interaction = 0.002), and total glutathione concentrations (vitamin D vs. placebo groups: +205 vs. -32 μmol/L; P-interaction = 0.02) compared with placebo. Intake of vitamin D supplements led to a significant decrease in fasting plasma glucose (vitamin D vs. placebo groups: -0.65 vs. -0.12 mmol/L; P-interaction = 0.01), systolic blood pressure (vitamin D vs. placebo groups: -0.2 vs. +5.5 mm Hg; P-interaction = 0.01), and diastolic blood pressure (vitamin D vs. placebo groups: -0.4 vs. +3.1 mm Hg; P-interaction = 0.01) compared with placebo. In conclusion, vitamin D supplementation for 9 wk

  14. Are serum gamma-glutamyl transferase, high-sensitivity C-reactive protein, and ischaemia-modified albumin useful in diagnosing PCOS?

    Science.gov (United States)

    Ozturk, Mustafa; Keskin, Ugur; Ozturk, Ozlem; Ulubay, Mustafa; Alanbay, İbrahim; Aydin, Aytekin; Yenen, Müfit Cemal

    2016-10-01

    We assessed the serum levels of gamma-glutamyl transferase (GGT), high-sensitivity C-reactive protein (hsCRP) and ischaemia-modified albumin (IMA) in patients with polycystic ovary syndrome (PCOS). Fifty-three patients with PCOS were included in our study along with 40 women with no PCOS as the control group. The patients were divided according to their body mass index (BMI). GGT levels were significantly higher in the women with PCOS than the women in the control group (p PCOS women who were normoweight and overweight than the normoweight and overweight women in the control group (p PCOS and the controls or between the normoweight and overweight subgroups. GGT may be associated with the diagnosis of PCOS when the threshold is set at >15.5 U/L. With the application of this threshold, raised GGT levels had 83% sensitivity (95% CI 0.70-0.90) and 67.5% specificity (95% CI 0.52-0.79), for the diagnosis of PCOS. In our study, GGT levels were elevated in the PCOS patients independent of BMI and could thus be an important marker of PCOS.

  15. Highly sensitive colorimetric detection of glucose in a serum based on DNA-embeded Au@Ag core–shell nanoparticles

    International Nuclear Information System (INIS)

    Kang, Fei; Xu, Kun; Hou, Xiangshu

    2015-01-01

    Glucose is a key energy substance in diverse biology and closely related to the life activities of the organism. To develop a simple and sensitive method for glucose detection is extremely urgent but still remains a key challenge. Herein, we report a colorimetric glucose sensor in a homogeneous system based on DNA-embedded core–shell Au@Ag nanoparticles. In this assay, a glucose substrate was first catalytically oxidized by glucose oxidase to produce H 2 O 2 which would further oxidize and gradually etch the outer silver shell of Au@Ag nanoparticles. Afterwards, the solution color changed from yellow to red and the surface plasmon resonance (SPR) band of Au@Ag nanoparticles declined and red-shifted from 430 to 516 nm. Compared with previous silver-based glucose colorimetric detection strategies, the distinctive SPR band change is superior to the color variation, which is critical to the high sensitivity of this assay. Benefiting from the outstanding optical property, robust stability and well-dispersion of the core–shell Au@AgNPs hybrid, this colorimetric assay obtained a detection limit of glucose as low as 10 nM, which is at least a 10-fold improvement over other AgNPs-based procedures. Moreover, this optical biosensor was successfully employed to the determination of glucose in fetal bovine serum. (paper)

  16. Vertically Aligned Nitrogen-Doped Carbon Nanotube Carpet Electrodes: Highly Sensitive Interfaces for the Analysis of Serum from Patients with Inflammatory Bowel Disease.

    Science.gov (United States)

    Wang, Qian; Subramanian, Palaniappan; Schechter, Alex; Teblum, Eti; Yemini, Reut; Nessim, Gilbert Daniel; Vasilescu, Alina; Li, Musen; Boukherroub, Rabah; Szunerits, Sabine

    2016-04-20

    The number of patients suffering from inflammatory bowel disease (IBD) is increasing worldwide. The development of noninvasive tests that are rapid, sensitive, specific, and simple would allow preventing patient discomfort, delay in diagnosis, and the follow-up of the status of the disease. Herein, we show the interest of vertically aligned nitrogen-doped carbon nanotube (VA-NCNT) electrodes for the required sensitive electrochemical detection of lysozyme in serum, a protein that is up-regulated in IBD. To achieve selective lysozyme detection, biotinylated lysozyme aptamers were covalently immobilized onto the VA-NCNTs. Detection of lysozyme in serum was achieved by measuring the decrease in the peak current of the Fe(CN)6(3-/4-) redox couple by differential pulse voltammetry upon addition of the analyte. We achieved a detection limit as low as 100 fM with a linear range up to 7 pM, in line with the required demands for the determination of lysozyme level in patients suffering from IBD. We attained the sensitive detection of biomarkers in clinical samples of healthy patients and individuals suffering from IBD and compared the results to a classical turbidimetric assay. The results clearly indicate that the newly developed sensor allows for a reliable and efficient analysis of lysozyme in serum.

  17. Significant Relationship Between Serum High-sensitivity C-Reactive Protein, High-density Lipoprotein Cholesterol Levels and Children With Kawasaki Disease and Coronary Artery Lesions

    Directory of Open Access Journals (Sweden)

    Chun-Yen Ou

    2009-09-01

    Conclusion: Our results support the possibility of ongoing low-grade inflammation late after the acute phase of KD in children with coronary aneurysms. Serum hs-CRP and HDL-C levels are associated with coronary artery lesions in children with KD.

  18. Determination of Glutamic Acid Decarboxylase (GAD65 in Pancreatic Islets and Its In Vitro and In Vivo Degradation Kinetics in Serum Using a Highly Sensitive Enzyme Immunoassay

    Directory of Open Access Journals (Sweden)

    Michael Schlosser

    2008-01-01

    Full Text Available Glutamic acid decarboxylase GAD65 autoantibodies (GADA are an established marker for autoimmune diabetes. Recently, the autoantigen GAD65 itself was proposed as biomarker of beta-cell loss for prediction of autoimmune diabetes and graft rejection after islet transplantation. Therefore, the GAD65 content in pancreatic islets of different species and its serum degradation kinetics were examined in this study using a sensitive immunoassay. GAD65 was found in quantities of 78 (human, 43.7 (LEW.1A rat and 37.4 (BB/OK rat ng per 1,000 islets, respectively, but not in mouse islets. The in vitro half-life of porcine GAD65 and human recombinant GAD65 ranged from 1.27 to 2.35 hours at 37°C in human serum, plasma and blood, and was unaffected by presence of GAD65 autoantibodies. After injecting 2,000 ng recombinant human GAD65 into LEW.1A rats, the in vivo half-life was 2.77 hours. GAD65 was undetectable after 24 hours in these animals, and for up to 48 hours following diabetes induction by streptozotocin in LEW.1A rats. Estimated from these data, at least 13 islets in rat and 1,875 in human must be simultaneously destroyed to detect GAD65 in circulation. These results should be taken into consideration in further studies aimed at examining the diagnostic relevance of GAD65.

  19. Correlation of human S100A12 (EN-RAGE) and high-sensitivity C-reactive protein as gingival crevicular fluid and serum markers of inflammation in chronic periodontitis and type 2 diabetes.

    Science.gov (United States)

    Pradeep, A R; Martande, Santosh S; Singh, Sonender Pal; Suke, Deepak Kumar; Raju, Arjun P; Naik, Savitha B

    2014-04-01

    The aim of the present study was to evaluate the levels and correlation of human S100A12 and high-sensitivity C-reactive protein (hs-CRP) in gingival crevicular fluid (GCF) and serum in chronic periodontitis (CP) subjects with and without type 2 diabetes mellitus (DM). A total of 44 subjects were divided into three groups: group 1 had 10 periodontally healthy subjects, group 2 consisted of 17 CP subjects and group 3 had 17 type 2 DM subjects with CP. GCF and serum levels of human S100A12 and hs-CRP were quantified using enzyme-linked immunosorbent assay and immunoturbidimetric analysis, respectively. The clinical outcomes evaluated were gingival index, probing depth and clinical attachment level and the correlations of the two inflammatory mediators with clinical parameters were evaluated. Both human S100A12 and hs-CRP levels increased from group 1 to group 2 to group 3. The GCF and serum values of both these inflammatory mediators correlated positively with each other and with the periodontal parameters evaluated (p < 0.05). Human S100A12 and hs-CRP can be considered as possible GCF and serum markers of inflammatory activity in CP and DM.

  20. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  1. Highly Sensitive Optical Receivers

    CERN Document Server

    Schneider, Kerstin

    2006-01-01

    Highly Sensitive Optical Receivers primarily treats the circuit design of optical receivers with external photodiodes. Continuous-mode and burst-mode receivers are compared. The monograph first summarizes the basics of III/V photodetectors, transistor and noise models, bit-error rate, sensitivity and analog circuit design, thus enabling readers to understand the circuits described in the main part of the book. In order to cover the topic comprehensively, detailed descriptions of receivers for optical data communication in general and, in particular, optical burst-mode receivers in deep-sub-µm CMOS are presented. Numerous detailed and elaborate illustrations facilitate better understanding.

  2. [Effects of periodontal mechanical therapy with local and systemic drugs on carotid artery and serum high-sensitivity C-reactive protein in rats with chronic periodontitis associated with atherosclerosis].

    Science.gov (United States)

    Ren, Xiuyun; Chang, Le; Yue, Zijie; Lin, Mu; Shi, Xuexue; Sun, Lili

    2013-10-01

    The aim of this study is to investigate the effects of serum high-sensitivity C-reactive protein (hsCRP) and the pathological changes in the carotid artery after periodontal mechanical therapy with local and systemic drugs in SD rats with chronic periodontitis (CP) associated with atherosclerosis (As). Thirty-five SD rats were randomly divided into two groups: control group (group A) and CP+As group (group B). Group B was further divided into the natural process group (B1), the periodontal mechanical treatment group (B2), the periodontal mechanical treatment plus local drugs group (B3), and the periodontal mechanical treatment plus local and systemic drugs group (B4). Each group comprised seven rats. Serum hsCRP levels were evaluated at baseline 1 week after the first periodontal therapy and 1, 3, and 5 weeks after the second periodontal therapy by enzyme linked immunosorbent assay (ELISA). The pathological lesion in the carotid artery plaque was stained with hematine and eosin. The levels of serum hsCRP in group B1 increased gradually as time passed and became significantly higher than that of the other groups five weeks after periodontal therapy (P periodontal therapy. After that, the levels of serum hsCRP decreased gradually but were still higher than that of group A (P periodontal therapy (P periodontal mechanical treatment results in acute, short-term, systemic inflammation and might increase the risk of atherosclerosis in SD rats. However, the levels of serum hsCRP decreased gradually 3 to 5 weeks after therapy. With periodontal mechanical treatment, the benefits of local and systemic drugs are associated with improvement in atherosclerotic lesion progression.

  3. Association of stem cell factor and high-sensitivity C reactive protein concentrations in crevicular fluid and serum in patients with chronic periodontitis with and without type 2 diabetes.

    Science.gov (United States)

    Kalra, Nitish; Pradeep, Avani R; Priyanka, Ningappa; Kumari, Minal

    2013-03-01

    The aim of the present study was to clarify whether there is any correlation between the levels of high-sensitivity C reactive protein (hs-CRP) and stem cell factor (SCF) in serum and gingival crevicular fluid (GCF) of patients with chronic periodontitis (CP) with and without type 2 diabetes mellitus (DM). A total of 40 subjects were divided into 3 groups: 10 periodontally healthy subjects (Group 1), 15 CP patients (Group 2), and 15 type 2 DM patients with CP (Group 3). Levels of hs-CRP and SCF in GCF and serum were quantified using different techniques. The clinical outcomes evaluated were gingival index (GI), probing depth (PD) and clinical attachment level (CAL), and the correlations of the two inflammatory mediators with clinical parameters were evaluated. The levels of these inflammatory mediators increased continuously from group 1 to group 2, and to group 3. The serum levels of both hs-CRP and SCF were correlated with PD in patients with CP (P periodontal disease, and elsewhere.

  4. Effect of Walnut Consumption on Serum Lipid Profiles, High-Sensitivity C-Reactive Protein and Nitric Oxide in Patients With Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Kalantarian

    2015-02-01

    Full Text Available Background Coronary artery disease (CAD is one of the major causes of death worldwide. There is a direct relationship between increased levels of blood cholesterol, triglycerides (TG, low density lipoproteins (LDL, high density lipoproteins (HDL, nitric oxide (NO, and high sensitivity C-reactive protein (hs-CRP and the CAD. Walnut may reduce these factors and consequently decrease the risk of CAD. Objectives The aim of this study was to evaluate the effect of walnut consumption on TG, LDL, cholesterol, HDL, NO, and hs-CRP in patients with CAD and healthy people. Patients and Methods In this randomized crossover clinical trial, 70 patients with CAD were divided into two groups: case and control groups. The patients were given 40 g walnuts daily for 4 weeks. After 4 weeks, the TG, LDL, cholesterol, HDL, NO and hs-CRP levels were measured. The experiment was also carried out on healthy people (3 groups with normal range of lipid. The LDL, HDL, cholesterol, and hs-CRP levels were measured using commercially available kits. The nitric oxide level was measured using the Griess reaction method. Results The cholesterol and LDL levels decreased significantly from 202.43 to 187.46 and 123.80 to 108.63 mmol/L (7.9% and 13.9 %, respectively in healthy subjects after the treatment (P < 0.01. In the experimental group, there was no significant difference in cholesterol (P = 0.110 and LDL levels (P = 0.176 before and after the treatment. Moreover, no significant difference was observed in other parameters between the two groups. Conclusions The walnut consumption did not affect cholesterol levels in patients with CAD; however, it might be administered as an agent for reducing the cholesterol, which is one of the risk factors associated with CAD.

  5. Identification of high-affinity anti-IL-1 α autoantibodies in normal human serum as an interfering substance in a sensitive enzyme-linked immunosorbent assay for IL-1 α

    International Nuclear Information System (INIS)

    Mae, N.; Liberato, D.J.; Chizzonite, R.; Satoh, H.

    1991-01-01

    A highly reproducible, sensitive, and specific sandwich enzyme-linked immunosorbent assay (ELISA) for recombinant human IL-1 α (rhIL-1 alpha) has been developed. Results from this ELISA have demonstrated that the concentration of rhIL-1 α added to normal human serum (NHS) decreased by 16.3% after 3 h and 24.9% after 6 h at room temperature. Molecular exclusion column chromatography with Sephacryl S-300 HR revealed that 125I-labeled IL-1 α added to normal human serum rapidly formed higher molecular weight complexes without indication of proteolytic degradation. The observed reduction in immunoreactivity was correlated with this protein complex formation and accounted for the apparent instability of rhIL-1 α in NHS. Immunoblot analysis indicated that the molecular weight of the binding protein was 150-160K, and the IL-1 α binding activity was removed and recovered from NHS by Protein-G affinity chromatography; indicating that the binding protein was IL-1 α-specific IgG. The binding of 125I-labeled IL-1 α to the serum binding proteins could be inhibited by unlabeled IL-1 alpha (IC50 = 7.4 x 10(-11) M) but not by unlabeled IL-1 β. Kinetic analysis with 125I-labeled IL-1 alpha revealed that the average binding affinity of these IL-1 α-specific IgGs was 4.7 x 10(10) M-1. These results suggest that these autoantibodies may interfere with the detection of IL-1 α in human serum by various assay systems and also could be a regulator of circulating IL-1 α

  6. Sensitive determination of pipecolic acid in serum by high-performance liquid chromatography using 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride as a fluorescent labelling reagent

    International Nuclear Information System (INIS)

    Inoue, Hirofumi; Sakata, Yasuhiko; Fukunaga, Keiko; Nishio, Hiroaki; Tsuruta, Yasuto

    2004-01-01

    A simple and highly sensitive high-performance liquid chromatography (HPLC) for the determination of pipecolic acid (PA) in serum was developed. Pipecolic acid and nipecotic acid (internal standard (IS)) were derivatised with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride (DMS-Cl) to produce fluorescent sulfonamides. The labelling reaction was carried out at 70 degree sign C for 15 min at pH 9.0. The fluorescent derivatives were separated on a reversed-phase column (45 degree sign C) with a stepwise elution using methanol/acetonitrile/10 mmol l -1 acetic acid (42:5:53) and methanol at a flow rate of 1.0 ml/min and detected at excitation and emission wavelengths of 316 and 403 nm, respectively. The labelling yield was 100.8%. The detection limit of pipecolic acid was 4 fmol at signal-to-noise ratio of 3. The within-day and day-to-day relative standard deviations were 3.3-8.1 and 1.4-6.4%, respectively. The concentration of pipecolic acid in normal human serum was 1.09±0.37 μmol l -1

  7. Association of Sarcopenic Obesity with Higher Serum High-Sensitivity C-Reactive Protein Levels in Chinese Older Males--A Community-Based Study (Taichung Community Health Study-Elderly, TCHS-E.

    Directory of Open Access Journals (Sweden)

    Chuan-Wei Yang

    Full Text Available The prevalence of obesity and sarcopenia is high among the elderly. The simultaneous occurrence of these two disorders results in sarcopenic obesity. Research suggests that inflammation has an important role in the pathogenesis of obesity and sarcopenia. This study explores the impact of sarcopenic obesity on inflammatory markers, including interleukin-6 (IL-6, high-sensitivity C-reactive protein (hs-CRP, and tumor necrosis factor-alpha (TNF-α. This study is a community-based cross-sectional study. The study sample consisted of 844 community-dwelling people aged 65 years and older (448 men and 396 women. Sarcopenia was characterized by low muscle mass (skeletal muscle index < 6.87 and 5.46 kg/m2 for men and women, respectively, and obesity was characterized by excess body fat (body fat percentage greater than the 60th percentile of the study sample by sex [27.82% in men and 37.61% in women]. Older individuals identified with sarcopenic obesity were those who had both sarcopenia and obesity. Inflammatory markers such as IL-6, hs-CRP, and TNF-α were measured. The prevalence rates of obesity only, sarcopenia only, and sarcopenic obesity were 32.94%, 11.85%, and 7.23%, respectively. No difference was observed in the serum levels of IL-6 and TNF-α among the four groups of combined sarcopenia and obesity status. After multivariate adjustment, the serum hs-CRP levels in the obesity only and in the sarcopenic obesity groups were 0.14 and 0.16 mg/dL among males, respectively, which were significantly higher than that in the normal group (P=0.012 and 0.036. Our results provide evidence that obesity and sarcopenic obesity are associated with increased levels of serum hs-CRP among males.

  8. The comparison of the effects of standard 20 mg atorvastatin daily and 20 mg atorvastatin every other day on serum LDL-cholesterol and high sensitive C-reactive protein levels.

    Science.gov (United States)

    Keleş, Telat; Akar Bayram, Nihal; Kayhan, Tuğba; Canbay, Alper; Sahin, Deniz; Durmaz, Tahir; Ozdemir, Ozcan; Aydoğdu, Sinan; Diker, Erdem

    2008-12-01

    In this study, we aimed at comparing the effects of standard once daily 20 mg atorvastatin treatment with that of atorvastatin 20 mg administered every other day on serum lipids and high sensitive C-reactive protein (hs-CRP) levels. Sixty-one patients with serum total cholesterol levels of above 200 mg/dl and low density lipoprotein (LDL)--cholesterol levels of above 130 mg/dl were included in this prospective, randomized study. The patients were randomized into daily treatment of 20 mg atorvastatin (standard treatment) and 20 mg atorvastatin every other day (every other day treatment) groups. Before the treatment and at each visit, serum lipids and hs-CRP levels of all the patients were measured. Statistical analyses were performed Chi-square, unpaired t and two-way repeated measurements ANOVA tests. In the every other day treatment group, there was a 36.1% reduction in LDL-cholesterol levels by the end of first month (p0.05). The LDL cholesterol levels of the group receiving 20 mg atorvastatin every day was reduced by %41 by the end of 1 month (pevery other day, there was a 21% decrease in hs-CRP levels compared to the basal measurements at the end of first month (pevery day the decrease in hs-CRP levels at the end of one month was more striking (37%, p0.05). Alternate-day dosing of atorvastatin causes a significant lipid-lowering and antiinflammatory effects similar to that of daily administration and yet may provide some cost savings.

  9. Highly sensitive and selective spectrofluorimetric determination of metoclopramide hydrochloride in pharmaceutical tablets and serum samples using Eu3+ ion doped in sol-gel matrix.

    Science.gov (United States)

    Attia, M S; Aboaly, M M

    2010-06-30

    A simple, sensitive and selective spectrofluorimetric method for the determination of Metoclopramide hydrochloride (MCP) is developed. The MCP can remarkably enhances the luminescence intensity of the Eu(3+) ion doped in sol-gel matrix at lambda(ex)=380 nm in DMSO at pH 8.7. The intensity of the emission band of Eu(3+) ion doped in sol-gel matrix increases due to energy transfer from MCP to Eu(3+) in the excited state. The enhancement of the emission band of Eu(3+) ion doped in sol-gel matrix at 617 nm was found to be directly proportional to the concentration of MCP with a dynamic range of 5 x 10(-9) - 1.0 x 10(-6) mol L(-1) and detection limit of 2.2 x10(-11) mol L(-1). Copyright 2010 Elsevier B.V. All rights reserved.

  10. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  11. Epicardial adipose tissue relating to anthropometrics, metabolic derangements and fatty liver disease independently contributes to serum high-sensitivity C-reactive protein beyond body fat composition: a study validated with computed tomography.

    Science.gov (United States)

    Lai, Yau-Huei; Yun, Chun-Ho; Yang, Fei-Shih; Liu, Chuan-Chuan; Wu, Yih-Jer; Kuo, Jen-Yuan; Yeh, Hung-I; Lin, Tin-Yu; Bezerra, Hiram G; Shih, Shou-Chuan; Tsai, Cheng-Ho; Hung, Chung-Lieh

    2012-02-01

    Epicardial adipose tissue (EAT) measured by echocardiography has been proposed to be associated with metabolic syndrome and increased cardiovascular risks. However, its independent association with fatty liver disease and systemic inflammation beyond clinical variables and body fat remains less well known. The relationships between EAT and various factors of metabolic derangement were retrospectively examined in consecutive 359 asymptomatic subjects (mean age, 51.6 years; 31% women) who participated in a cardiovascular health survey. Echocardiography-derived regional EAT thickness from parasternal long-axis and short-axis views was quantified. A subset of data from 178 randomly chosen participants were validated using 16-slice multidetector computed tomography. Body fat composition was evaluated using bioelectrical impedance from foot-to-foot measurements. Increased EAT was associated with increased waist circumference, body weight, and body mass index (all P values for trend = .005). Graded increases in serum fasting glucose, insulin resistance, and alanine transaminase levels were observed across higher EAT tertiles as well as a graded decrease of high-density lipoprotein (all P values for trend <.05). The areas under the receiver operating characteristic curves for identifying metabolic syndrome and fatty liver disease were 0.8 and 0.77, with odds ratio estimated at 3.65 and 2.63, respectively. In a multivariate model, EAT remained independently associated with higher high-sensitivity C-reactive protein and fatty liver disease. These data suggested that echocardiography-based epicardial fat measurement can be clinically feasible and was related to several metabolic abnormalities and independently associated fatty liver disease. In addition, EAT amount may contribute to systemic inflammation beyond traditional cardiovascular risks and body fat composition. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  12. High order depletion sensitivity analysis

    International Nuclear Information System (INIS)

    Naguib, K.; Adib, M.; Morcos, H.N.

    2002-01-01

    A high order depletion sensitivity method was applied to calculate the sensitivities of build-up of actinides in the irradiated fuel due to cross-section uncertainties. An iteration method based on Taylor series expansion was applied to construct stationary principle, from which all orders of perturbations were calculated. The irradiated EK-10 and MTR-20 fuels at their maximum burn-up of 25% and 65% respectively were considered for sensitivity analysis. The results of calculation show that, in case of EK-10 fuel (low burn-up), the first order sensitivity was found to be enough to perform an accuracy of 1%. While in case of MTR-20 (high burn-up) the fifth order was found to provide 3% accuracy. A computer code SENS was developed to provide the required calculations

  13. High serum enalaprilat in chronic renal failure

    DEFF Research Database (Denmark)

    Elung-Jensen, T; Heisterberg, J; Kamper, A L

    2001-01-01

    renal failure. METHODS: Fifty nine out-patients with plasma creatinine >150 micromol/L and chronic antihypertensive treatment with enalapril were investigated, in a cross-sectional design. RESULTS: Median glomerular filtration rate (GFR) was 23(range 6-60) ml/minute/1.73 m2. The daily dose of enalapril......-68) ml/minute and correlated linearly with GFR (r=0.86, p=0.003). Intra-subject day-to-day variation in trough concentrations was 19.7%. CONCLUSION: Patients with chronic renal failure given small or moderately high doses of enalapril may thus have markedly elevated levels of serum enalaprilat. Whether...

  14. Human gut microbes impact host serum metabolome and insulin sensitivity

    DEFF Research Database (Denmark)

    Pedersen, Helle Krogh; Gudmundsdottir, Valborg; Nielsen, Henrik Bjørn

    2016-01-01

    Insulin resistance is a forerunner state of ischaemic cardiovascular disease and type 2 diabetes. Here we show how the human gut microbiome impacts the serum metabolome and associates with insulin resistance in 277 non-diabetic Danish individuals. The serum metabolome of insulin-resistant individ......Insulin resistance is a forerunner state of ischaemic cardiovascular disease and type 2 diabetes. Here we show how the human gut microbiome impacts the serum metabolome and associates with insulin resistance in 277 non-diabetic Danish individuals. The serum metabolome of insulin......-resistant individuals is characterized by increased levels of branched-chain amino acids (BCAAs), which correlate with a gut microbiome that has an enriched biosynthetic potential for BCAAs and is deprived of genes encoding bacterial inward transporters for these amino acids. Prevotella copri and Bacteroides vulgatus...

  15. Effects of daily consumption of synbiotic bread on insulin metabolism and serum high-sensitivity C-reactive protein among diabetic patients: a double-blind, randomized, controlled clinical trial.

    Science.gov (United States)

    Tajadadi-Ebrahimi, Maryam; Bahmani, Fereashteh; Shakeri, Hossein; Hadaegh, Haleh; Hijijafari, Mohammad; Abedi, Fatemeh; Asemi, Zatollah

    2014-01-01

    This study was conducted to evaluate the effects of daily consumption of synbiotic bread on the metabolic status of patients with type 2 diabetes mellitus. This randomized, double-blind, controlled clinical trial was performed in 81 diabetic patients. The subjects were randomly assigned to consumption of synbiotic (n = 27), probiotic (n = 27), or control bread (n = 27) for 8 weeks 3 times a day in a 40-gram package. The synbiotic bread contained Lactobacillus sporogenes (1 × 10(8) CFU) and 0.07 g inulin per 1 g. The probiotic bread contained L. sporogenes (1 × 10(8) CFU per 1 g). Fasting blood samples were taken at baseline and after an 8-week intervention for quantification of related factors. Consumption of the synbiotic bread resulted in a significant reduction in serum insulin levels (-3.2 ± 5.4 vs. -0.3 ± 3.4 and 0.6 ± 4.7 µIU/ml, respectively, p = 0.007), homeostatic model assessment for insulin resistance scores (-1.5 ± 2.7 vs. -0.2 ± 1.6 and 0.4 ± 3.5, respectively, p = 0.03), and homeostatic model assessment-β-cell function (-7.2 ± 16.3 vs. -0.7 ± 10.8 and 0.7 ± 8.2, respectively, p = 0.04) compared to the probiotic and control breads. We did not find any significant effect of synbiotic bread consumption on fasting plasma glucose, the quantitative insulin sensitivity check index, or serum hs-CRP levels compared to other breads. Consumption of the synbiotic bread among diabetic patients had beneficial effects on insulin metabolism. © 2014 S. Karger AG, Basel.

  16. Association Between Smoking and Serum GlycA and High-Sensitivity C-Reactive Protein Levels: The Multi-Ethnic Study of Atherosclerosis (MESA) and Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Kianoush, Sina; Bittencourt, Marcio S; Lotufo, Paulo A; Bensenor, Isabela M; Jones, Steven R; DeFilippis, Andrew P; Toth, Peter P; Otvos, James D; Tibuakuu, Martin; Hall, Michael E; Harada, Paulo H N; Blaha, Michael J

    2017-08-23

    Inflammation is suggested to be a central feature of atherosclerosis, particularly among smokers. We studied whether inflammatory biomarkers GlycA and high-sensitivity C-reactive protein are associated with cigarette smoking. A total of 11 509 participants, 6774 from the MESA (Multi-Ethnic Study of Atherosclerosis) and 4735 from ELSA-Brasil (The Brazilian Longitudinal Study of Adult Health) were included. We evaluated the cross-sectional association between multiple measures of smoking behavior and the inflammatory biomarkers, GlycA and high-sensitivity C-reactive protein, using regression models adjusted for demographic, anthropometric, and clinical characteristics. Participants were 57.7±11.1 years old and 46.4% were men. Never, former, and current smokers comprised 51.7%, 34.0%, and 14.3% of the population, respectively. Multivariable-adjusted mean absolute difference in GlycA levels (μmol/L) with 95% confidence interval (CI) were higher for former (4.1, 95% CI, 1.7-6.6 μmol/L) and current smokers (19.9, 95% CI, 16.6-23.2 μmol/L), compared with never smokers. Each 5-unit increase in pack-years of smoking was associated with higher GlycA levels among former (0.7, 95% CI, 0.3-1.1 μmol/L) and current smokers (1.6, 95% CI, 0.8-2.4 μmol/L). Among former smokers, each 5-year increase in time since quitting smoking was associated with lower GlycA levels (-1.6, 95% CI, -2.4 to -0.8 μmol/L) and each 10-unit increase in number of cigarettes/day was associated with higher GlycA among current smokers (2.8, 95% CI, 0.5-5.2 μmol/L). There were similar significant associations between all measures of smoking behavior, and both log-transformed GlycA and high-sensitivity C-reactive protein. Acute and chronic exposure to tobacco smoking is associated with inflammation, as quantified by both GlycA and high-sensitivity C-reactive protein. These biomarkers may have utility for the study and regulation of novel and traditional tobacco products. © 2017 The Authors

  17. [Bactericidal activity of serum and chemotherapy in sensitive and resistant exciter (author's transl)].

    Science.gov (United States)

    Eyer, H; Metz, H; Preac-Mursic, V

    1975-11-21

    Comparing examinations with Ampicillin sensitive and resistant bacteria-strains show that the bactericidal activity of serum is dependent on the bacteria-strains, on the Ampicillin sensitivity of the particular exciter and on the number of bacteria/ml (germ count). Bactericide effect could always be obtained with sensitive strains as a result of additional chemotherapy. With several resistant strains a bactericide effect could not be obtained in this case the continuous optimal Ampicillin addition was the decisive factor. Because of the extremely complicated process of the bactericide one should not make general conclusions from the individual experimental results.

  18. Serum creatine kinase elevations in ultramarathon runners at high altitude.

    Science.gov (United States)

    Magrini, Danielle; Khodaee, Morteza; San-Millán, Iñigo; Hew-Butler, Tamara; Provance, Aaron J

    2017-05-01

    Creatine kinase (CK) is a sensitive enzyme marker for muscle damage in athletes. Elevated CK levels have been reported in many endurance physical activities. The consequence and possible long-term sequela of the CK elevation in athletes is unknown. There is a paucity of literature stating actual numerical values of CK associated with competing in an ultramarathon with extreme environmental conditions. Our hypothesis was that the serum CK levels increase significantly as a result of running a 161 km ultramarathon at high altitude. This was a prospective observational study of participants of the Leadville 100 ultramarathon race in Leadville, Colorado at high altitude (2800-3840 m) in August 2014. We collected blood samples from sixty-four volunteer runners before and eighty-three runners immediately after the race. Out of 669 athletes who started the race, 352 successfully completed the race in less than the 30-hour cut-off time (52%). The majority of runners were male (84%). We were able to collect both pre- and post-race blood samples from 36 runners. Out of these 36 runners, the mean pre-race CK was increased from 126 ± 64 U/L to 14,569 ± 14,729 U/L (p athletes' age, BMI, or finishing time. Significant elevation of CK level occurs as a result of running ultramarathons. The majority of athletes with significantly elevated CK levels were asymptomatic and required no major medical attention.

  19. DNA-mediated strand displacement facilitates sensitive electronic detection of antibodies in human serums.

    Science.gov (United States)

    Dou, Baoting; Yang, Jianmei; Shi, Kai; Yuan, Ruo; Xiang, Yun

    2016-09-15

    We describe here the development of a sensitive and convenient electronic sensor for the detection of antibodies in human serums. The sensor is constructed by self-assembly formation of a mixed monolayer containing the small molecule epitope conjugated double stranded DNA probes on gold electrode. The target antibody binds the epitope on the dsDNA probe and lowers the melting temperature of the duplex, which facilitates the displacement of the antibody-linked strand of the duplex probe by an invading methylene blue-tagged single stranded DNA (MB-ssDNA) through the strand displacement reaction and leads to the capture of many MB-ssDNA on the sensor surface. Subsequent electrochemical oxidation of the methylene blue labels results in amplified current response for sensitive monitoring of the antibodies. The antibody assay conditions are optimized and the sensor exhibits a linear range between 1.0 and 25.0nM with a detection limit of 0.67nM for the target antibody. The sensor is also selective and can be employed to detect the target antibodies in human serum samples. With the advantages of using small molecule epitope as the antibody recognition element over traditional antigen, the versatile manipulability of the DNA probes and the unique properties of the electrochemical transduction technique, the developed sensor thus hold great potential for simple and sensitive detection of different antibodies and other proteins in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Serum Is Not Necessary for Prior Pharmacological Activation of AMPK to Increase Insulin Sensitivity of Mouse Skeletal Muscle

    Directory of Open Access Journals (Sweden)

    Nicolas O. Jørgensen

    2018-04-01

    Full Text Available Exercise, contraction, and pharmacological activation of AMP-activated protein kinase (AMPK by 5-aminoimidazole-4-carboxamide ribonucleotide (AICAR have all been shown to increase muscle insulin sensitivity for glucose uptake. Intriguingly, improvements in insulin sensitivity following contraction of isolated rat and mouse skeletal muscle and prior AICAR stimulation of isolated rat skeletal muscle seem to depend on an unknown factor present in serum. One study recently questioned this requirement of a serum factor by showing serum-independency with muscle from old rats. Whether a serum factor is necessary for prior AICAR stimulation to increase insulin sensitivity of mouse skeletal muscle is not known. Therefore, we investigated the necessity of serum for this effect of AICAR in mouse skeletal muscle. We found that the ability of prior AICAR stimulation to improve insulin sensitivity of mouse skeletal muscle did not depend on the presence of serum during AICAR stimulation. Although prior AICAR stimulation did not enhance proximal insulin signaling, insulin-stimulated phosphorylation of Tre-2/BUB2/CDC16- domain family member 4 (TBC1D4 Ser711 was greater in prior AICAR-stimulated muscle compared to all other groups. These results imply that the presence of a serum factor is not necessary for prior AMPK activation by AICAR to enhance insulin sensitivity of mouse skeletal muscle.

  1. DJ-1 is a reliable serum biomarker for discriminating high-risk endometrial cancer.

    Science.gov (United States)

    Di Cello, Annalisa; Di Sanzo, Maddalena; Perrone, Francesca Marta; Santamaria, Gianluca; Rania, Erika; Angotti, Elvira; Venturella, Roberta; Mancuso, Serafina; Zullo, Fulvio; Cuda, Giovanni; Costanzo, Francesco

    2017-06-01

    New reliable approaches to stratify patients with endometrial cancer into risk categories are highly needed. We have recently demonstrated that DJ-1 is overexpressed in endometrial cancer, showing significantly higher levels both in serum and tissue of patients with high-risk endometrial cancer compared with low-risk endometrial cancer. In this experimental study, we further extended our observation, evaluating the role of DJ-1 as an accurate serum biomarker for high-risk endometrial cancer. A total of 101 endometrial cancer patients and 44 healthy subjects were prospectively recruited. DJ-1 serum levels were evaluated comparing cases and controls and, among endometrial cancer patients, between high- and low-risk patients. The results demonstrate that DJ-1 levels are significantly higher in cases versus controls and in high- versus low-risk patients. The receiver operating characteristic curve analysis shows that DJ-1 has a very good diagnostic accuracy in discriminating endometrial cancer patients versus controls and an excellent accuracy in distinguishing, among endometrial cancer patients, low- from high-risk cases. DJ-1 sensitivity and specificity are the highest when high- and low-risk patients are compared, reaching the value of 95% and 99%, respectively. Moreover, DJ-1 serum levels seem to be correlated with worsening of the endometrial cancer grade and histotype, making it a reliable tool in the preoperative decision-making process.

  2. Phase sensitive diffraction sensor for high sensitivity refractive index measurement

    Science.gov (United States)

    Kumawat, Nityanand; Varma, Manoj; Kumar, Sunil

    2018-02-01

    In this study a diffraction based sensor has been developed for bio molecular sensing applications and performing assays in real time. A diffraction grating fabricated on a glass substrate produced diffraction patterns both in transmission and reflection when illuminated by a laser diode. We used zeroth order I(0,0) as reference and first order I(0,1) as signal channel and conducted ratiometric measurements that reduced noise by more than 50 times. The ratiometric approach resulted in a very simple instrumentation with very high sensitivity. In the past, we have shown refractive index measurements both for bulk and surface adsorption using the diffractive self-referencing approach. In the current work we extend the same concept to higher diffraction orders. We have considered order I(0,1) and I(1,1) and performed ratiometric measurements I(0,1)/I(1,1) to eliminate the common mode fluctuations. Since orders I(0,1) and I(1,1) behaved opposite to each other, the resulting ratio signal amplitude increased more than twice compared to our previous results. As a proof of concept we used different salt concentrations in DI water. Increased signal amplitude and improved fluid injection system resulted in more than 4 times improvement in detection limit, giving limit of detection 1.3×10-7 refractive index unit (RIU) compared to our previous results. The improved refractive index sensitivity will help significantly for high sensitivity label free bio sensing application in a very cost-effective and simple experimental set-up.

  3. High sensitivity optical molecular imaging system

    Science.gov (United States)

    An, Yu; Yuan, Gao; Huang, Chao; Jiang, Shixin; Zhang, Peng; Wang, Kun; Tian, Jie

    2018-02-01

    Optical Molecular Imaging (OMI) has the advantages of high sensitivity, low cost and ease of use. By labeling the regions of interest with fluorescent or bioluminescence probes, OMI can noninvasively obtain the distribution of the probes in vivo, which play the key role in cancer research, pharmacokinetics and other biological studies. In preclinical and clinical application, the image depth, resolution and sensitivity are the key factors for researchers to use OMI. In this paper, we report a high sensitivity optical molecular imaging system developed by our group, which can improve the imaging depth in phantom to nearly 5cm, high resolution at 2cm depth, and high image sensitivity. To validate the performance of the system, special designed phantom experiments and weak light detection experiment were implemented. The results shows that cooperated with high performance electron-multiplying charge coupled device (EMCCD) camera, precision design of light path system and high efficient image techniques, our OMI system can simultaneously collect the light-emitted signals generated by fluorescence molecular imaging, bioluminescence imaging, Cherenkov luminance and other optical imaging modality, and observe the internal distribution of light-emitting agents fast and accurately.

  4. Evaluation of a fluorescence polarographic immunoassay with increased sensitivity for measurement of low concentrations of tobramycin in serum

    NARCIS (Netherlands)

    Touw, D J; de Graaf, A I; de Goede, P

    The limits of quantitation of the assay of tobramycin in serum by the fluorescence polarization immunoassay system marketed by Abbott Laboratories (TDxFLx system) are 0.1 and 10.0 mg/L. For some pharmacokinetic studies, however, a more sensitive analysis is needed. The sensitivity of the TDxFLx

  5. Serum biomarker profile associated with high bone turnover and BMD in postmenopausal women.

    Science.gov (United States)

    Bhattacharyya, Sudeepa; Siegel, Eric R; Achenbach, Sara J; Khosla, Sundeep; Suva, Larry J

    2008-07-01

    Early diagnosis of the onset of osteoporosis is key to the delivery of effective therapy. Biochemical markers of bone turnover provide a means of evaluating skeletal dynamics that complements static measurements of BMD by DXA. Conventional clinical measurements of bone turnover, primarily the estimation of collagen and its breakdown products in the blood or urine, lack both sensitivity and specificity as a reliable diagnostic tool. As a result, improved tests are needed to augment the use of BMD measurements as the principle diagnostic modality. In this study, the serum proteome of 58 postmenopausal women with high or low/normal bone turnover (training set) was analyzed by surface enhanced laser-desorption/ionization time-of-flight mass spectrometry, and a diagnostic fingerprint was identified using a variety of statistical and machine learning tools. The diagnostic fingerprint was validated in a separate distinct test set, consisting of serum samples from an additional 59 postmenopausal women obtained from the same Mayo cohort, with a gap of 2 yr. Specific protein peaks that discriminate between postmenopausal patients with high or low/normal bone turnover were identified and validated. Multiple supervised learning approaches were able to classify the level of bone turnover in the training set with 80% sensitivity and 100% specificity. In addition, the individual protein peaks were also significantly correlated with BMD measurements in these patients. Four of the major discriminatory peaks in the diagnostic profile were identified as fragments of interalpha-trypsin-inhibitor heavy chain H4 precursor (ITIH4), a plasma kallikrein-sensitive glycoprotein that is a component of the host response system. These data suggest that these serum protein fragments are the serum-borne reflection of the increased osteoclast activity, leading to the increased bone turnover that is associated with decreasing BMD and presumably an increased risk of fracture. In conjunction with the

  6. Heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Olsen, Jakob Lind

    This thesis present a highly sensitive silicon microreactor and examples of its use in studying catalysis. The experimental setup built for gas handling and temperature control for the microreactor is described. The implementation of LabVIEW interfacing for all the experimental parts makes...

  7. Aluminum nanocantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nanocantilevers using a simple, one mask contact UV lithography technique with lateral and vertical dimensions under 500 and 100 nm, respectively. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Furthermore, it is shown ...

  8. Canine serum protein patterns using high-resolution electrophoresis (HRE).

    Science.gov (United States)

    Abate, O; Zanatta, R; Malisano, T; Dotta, U

    2000-03-01

    Serum protein values were determined in 26 healthy dogs using agarose gel electrophoresis (SPE), splitting the electrophoretic separation into six regions: albumin, alpha(1), alpha(2), beta(1), beta(2)and gamma globulins. High-resolution electrophoresis (HRE) was used to separate single proteins. Serum proteins from dogs (26 healthy and 20 affected by various diseases) were then characterized by electrophoretic immunofixation (IFE) and Sudan black staining on HRE film. Haemoglobin and normal canine plasma and serum were used to identify haptoglobin and fibrinogen, respectively. In the standard pattern, determined by HRE, the following proteins were identified: albumin, alpha(1)-lipoprotein (alpha(1)-region), haptoglobin and alpha(2)-macroglobulin (alpha(2)-region), beta -lipoprotein and C3 (beta(1)-region), transferrin and IgM (beta(2)-region), IgG (mostly in gamma -region and partly in beta(2)-region). The HRE pattern shown by healthy dogs could be compared with those of dogs affected by various diseases to obtain clinical information. Copyright 2000 Harcourt Publishers Ltd.

  9. High levels of serum hyaluronic acid in adults with dermatomyositis

    Directory of Open Access Journals (Sweden)

    Alana Ausciutti Victorino

    2015-04-01

    Full Text Available Background / objectives. Hyaluronic acid (HA is rarely described in dermatomyositis (DM. Thus, we determined any clinical association of serum levels of hyaluronic acid (HA in patients with dermatomyositis (DM. Materials and Methods. This cross-sectional single-center analysis 75 DM and 75 healthy individuals, during the period from January 2012 to July 2013. An anti-HA antibody assay was performed using specific ELISA/EIA kits, according to the manufacturer’s protocol. Results. The patients with DM and control subjects had comparable demographic distributions (p>0.05. The median time duration between disease diagnosis and initial symptoms was 6.0 [3.0-12.0] months, with a median DM disease duration of 4.0 [1.0-7.0] years. The median level of serum HA was significantly increased in patients with DM compared to the control group [329.0 (80.0-958.0 vs. 133.0 (30.0-262.0 ng/mL, respectively; p0.05. Serum HA also did not correlate with gender, ethnicity, auto-antibodies or drug use (p>0.05, but did correlate with cutaneous features, such as photosensitivity (p=0.001, “shawl” sign (p=0.018, “V-neck” sign (p=0.005 and cuticular hypertrophy (p=0.014. Conclusions. A high level of serum AH was observed in DM compared to healthy individuals. In DM, HA did not correlate to demographic, auto-antibodies and therapy parameters. However, HA correlated specifically with some cutaneous features, suggesting that this glycosaminoglycan could be involved in modulating cutaneous inflammation in this population. More studies are necessary to understand the correlation between AH and patients with DM.

  10. Single photon detector with high polarization sensitivity.

    Science.gov (United States)

    Guo, Qi; Li, Hao; You, LiXing; Zhang, WeiJun; Zhang, Lu; Wang, Zhen; Xie, XiaoMing; Qi, Ming

    2015-04-15

    Polarization is one of the key parameters of light. Most optical detectors are intensity detectors that are insensitive to the polarization of light. A superconducting nanowire single photon detector (SNSPD) is naturally sensitive to polarization due to its nanowire structure. Previous studies focused on producing a polarization-insensitive SNSPD. In this study, by adjusting the width and pitch of the nanowire, we systematically investigate the preparation of an SNSPD with high polarization sensitivity. Subsequently, an SNSPD with a system detection efficiency of 12% and a polarization extinction ratio of 22 was successfully prepared.

  11. [Reversed-phase high-performance liquid chromatograph--application to serum aluminium monitoring].

    Science.gov (United States)

    Hoshino, H; Kaneko, E

    1996-01-01

    High-Performance Liquid Chromatography (HPLC) with the reversed-phase partition mode separation (including ion-pair one) towards metal chelate compounds prepared in an off-line fashion (precolumn chelation) is most versatile in terms of high sensitivity with base-line flatness, unique selectivity and cost effectiveness. The extraordinary toughness to the complicated matrices encountered in clinical testing is exemplified by the successful application to the aluminium monitoring of human serum samples. The A1 chelate with 2,2'-dihydroxyazobenzene is efficiently chromatographed on a LiChroCART RP-18 column using an aqueous methanol eluent (63.6 wt%) containing tetrabutylammonium bromide as an ion-pair agent. The serum concentration level of A1 down to 6 micrograms dm-3 is readily monitored without influences from iron, chyle and haemolysis.

  12. Highly sensitive microcalorimeters for radiation research

    International Nuclear Information System (INIS)

    Avaev, V.N.; Demchuk, B.N.; Ioffe, L.A.; Efimov, E.P.

    1984-01-01

    Calorimetry is used in research at various types of nuclear-physics installations to obtain information on the quantitative and qualitative composition of ionizing radiation in a reactor core and in the surrounding layers of the biological shield. In this paper, the authors examine the characteristics of highly sensitive microcalorimeters with modular semiconductor heat pickups designed for operation in reactor channels. The microcalorimeters have a thin-walled aluminum housing on whose inner surface modular heat pickups are placed radially as shown here. The results of measurements of the temperature dependence of the sensitivity of the microcalorimeters are shown. The results of measuring the sensitivity of a PMK-2 microcalorimeter assembly as a function of integrated neutron flux for three energy intervals and the adsorbed gamma energy are shown. In order to study specimens with different shapes and sizes, microcalorimeters with chambers in the form of cylinders and a parallelepiped were built and tested

  13. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  14. Low Cost, Low Power, High Sensitivity Magnetometer

    Science.gov (United States)

    2008-12-01

    which are used to measure the small magnetic signals from brain. Other types of vector magnetometers are fluxgate , coil based, and magnetoresistance...concentrator with the magnetometer currently used in Army multimodal sensor systems, the Brown fluxgate . One sees the MEMS fluxgate magnetometer is...Guedes, A.; et al., 2008: Hybrid - LOW COST, LOW POWER, HIGH SENSITIVITY MAGNETOMETER A.S. Edelstein*, James E. Burnette, Greg A. Fischer, M.G

  15. Highly sensitive and multiplexed platforms for allergy diagnostics

    Science.gov (United States)

    Monroe, Margo R.

    Allergy is a disorder of the immune system caused by an immune response to otherwise harmless environmental allergens. Currently 20% of the US population is allergic and 90% of pediatric patients and 60% of adult patients with asthma have allergies. These percentages have increased by 18.5% in the past decade, with predicted similar trends for the future. Here we design sensitive, multiplexed platforms to detect allergen-specific IgE using the Interferometric Reflectance Imaging Sensor (IRIS) for various clinical settings. A microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of patient blood sample. However, conventional fluorescent microarray technology is limited by i) the variation of probe immobilization, which hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics and ii) the use of fluorophore labels, which is not suitable for some clinical applications due to the tendency of fluorophores to stick to blood particulates and require daily calibration methods. This calibrated fluorescence enhancement (CaFE) method integrates the low magnification modality of IRIS with enhanced fluorescence sensing in order to directly correlate immobilized probe (major allergens) density to allergen-specific IgE in patient serum. However, this platform only operates in processed serum samples, which is not ideal for point of care testing. Thus, a high magnification modality of IRIS was adapted as an alternative allergy diagnostic platform to automatically discriminate and size single nanoparticles bound to specific IgE in unprocessed, characterized human blood and serum samples. These features make IRIS an ideal candidate for clinical and diagnostic applications, such a POC testing. The high magnification (nanoparticle counting) modality in conjunction with low magnification of IRIS in a combined instrument

  16. Review of high-sensitivity Radon studies

    Science.gov (United States)

    Wojcik, M.; Zuzel, G.; Simgen, H.

    2017-10-01

    A challenge in many present cutting-edge particle physics experiments is the stringent requirements in terms of radioactive background. In peculiar, the prevention of Radon, a radioactive noble gas, which occurs from ambient air and it is also released by emanation from the omnipresent progenitor Radium. In this paper we review various high-sensitivity Radon detection techniques and approaches, applied in the experiments looking for rare nuclear processes happening at low energies. They allow to identify, quantitatively measure and finally suppress the numerous sources of Radon in the detectors’ components and plants.

  17. High sensitivity troponin and valvular heart disease.

    Science.gov (United States)

    McCarthy, Cian P; Donnellan, Eoin; Phelan, Dermot; Griffin, Brian P; Enriquez-Sarano, Maurice; McEvoy, John W

    2017-07-01

    Blood-based biomarkers have been extensively studied in a range of cardiovascular diseases and have established utility in routine clinical care, most notably in the diagnosis of acute coronary syndrome (e.g., troponin) and the management of heart failure (e.g., brain-natriuretic peptide). The role of biomarkers is less well established in the management of valvular heart disease (VHD), in which the optimal timing of surgical intervention is often challenging. One promising biomarker that has been the subject of a number of recent VHD research studies is high sensitivity troponin (hs-cTn). Novel high-sensitivity assays can detect subclinical myocardial damage in asymptomatic individuals. Thus, hs-cTn may have utility in the assessment of asymptomatic patients with severe VHD who do not have a clear traditional indication for surgical intervention. In this state-of-the-art review, we examine the current evidence for hs-cTn as a potential biomarker in the most commonly encountered VHD conditions, aortic stenosis and mitral regurgitation. This review provides a synopsis of early evidence indicating that hs-cTn has promise as a biomarker in VHD. However, the impact of its measurement on clinical practice and VHD outcomes needs to be further assessed in prospective studies before routine clinical use becomes a reality. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Highly sensitive high resolution Raman spectroscopy using resonant ionization methods

    International Nuclear Information System (INIS)

    Owyoung, A.; Esherick, P.

    1984-05-01

    In recent years, the introduction of stimulated Raman methods has offered orders of magnitude improvement in spectral resolving power for gas phase Raman studies. Nevertheless, the inherent weakness of the Raman process suggests the need for significantly more sensitive techniques in Raman spectroscopy. In this we describe a new approach to this problem. Our new technique, which we call ionization-detected stimulated Raman spectroscopy (IDSRS), combines high-resolution SRS with highly-sensitive resonant laser ionization to achieve an increase in sensitivity of over three orders of magnitude. The excitation/detection process involves three sequential steps: (1) population of a vibrationally excited state via stimulated Raman pumping; (2) selective ionization of the vibrationally excited molecule with a tunable uv source; and (3) collection of the ionized species at biased electrodes where they are detected as current in an external circuit

  19. Pentobarbital quantitation using EMIT serum barbiturate assay reagents: application to monitoring of high-dose pentobarbital therapy.

    Science.gov (United States)

    Pape, B E; Cary, P L; Clay, L C; Godolphin, W

    1983-01-01

    Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.

  20. CALDER: High-sensitivity cryogenic light detectors

    International Nuclear Information System (INIS)

    Casali, N.; Bellini, F.; Cardani, L.

    2017-01-01

    The current bolometric experiments searching for rare processes such as neutrinoless double-beta decay or dark matter interaction demand for cryogenic light detectors with high sensitivity, large active area and excellent scalability and radio-purity in order to reduce their background budget. The CALDER project aims to develop such kind of light detectors implementing phonon-mediated Kinetic Inductance Detectors (KIDs). The goal for this project is the realization of a 5 × 5 cm"2 light detector working between 10 and 100mK with a baseline resolution RMS below 20 eV. In this work the characteristics and the performances of the prototype detectors developed in the first project phase will be shown.

  1. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  2. High sensitivity amplifier/discriminator for PWC's

    International Nuclear Information System (INIS)

    Hansen, S.

    1983-01-01

    The facility support group at Fermilab is designing and building a general purpose beam chamber for use in several locations at the laboratory. This pwc has 128 wires per plane spaced 1 mm apart. An initial production of 25 signal planes is anticipated. In proportional chambers, the size of the signal depends exponentially on the charge stored per unit of length along the anode wire. As the wire spacing decreases, the capacitance per unit length decreases, thereby requiring increased applied voltage to restore the necessary charge per unit length. In practical terms, this phenomenon is responsible for difficulties in constructing chambers with less than 2 mm wire spacing. 1 mm chambers, therefore, are frequently operated very near to their breakdown point and/or a high gain gas containing organic compounds such as magic gas is used. This argon/iso-butane mixture has three drawbacks: it is explosive when exposed to the air, it leaves a residue on the wires after extended use and is costly. An amplifier with higher sensitivity would reduce the problems associated with operating chambers with small wire spacings and allow them to be run a safe margin below their breakdown voltage even with an inorganic gas mixture such as argon/CO2, this eliminating the need to use magic gas. Described here is a low cost amplifier with a usable threshold of less than 0.5 μA. Data on the performance of this amplifier/discriminator in operation on a prototype beam chamber are given. This data shows the advantages of the high sensitivity of this design

  3. High sensitive radiation detector for radiology dosimetry

    International Nuclear Information System (INIS)

    Valente, M.; Malano, F.; Molina, W.; Vedelago, J.

    2014-08-01

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  4. Cys34-cysteinylated human serum albumin is a sensitive plasma marker in oxidative stress-related chronic diseases.

    Directory of Open Access Journals (Sweden)

    Kohei Nagumo

    Full Text Available The degree of oxidized cysteine (Cys 34 in human serum albumin (HSA, as determined by high performance liquid chromatography (HPLC, is correlated with oxidative stress related pathological conditions. In order to further characterize the oxidation of Cys34-HSA at the molecular level and to develop a suitable analytical method for a rapid and sensitive clinical laboratory analysis, the use of electrospray ionization time-of-flight mass spectrometer (ESI-TOFMS was evaluated. A marked increase in the cysteinylation of Cys34 occurs in chronic liver and kidney diseases and diabetes mellitus. A significant positive correlation was observed between the Cys-Cys34-HSA fraction of plasma samples obtained from 229 patients, as determined by ESI-TOFMS, and the degree of oxidized Cys34-HSA determined by HPLC. The Cys-Cys34-HSA fraction was significantly increased with the progression of liver cirrhosis, and was reduced by branched chain amino acids (BCAA treatment. The changes in the Cys-Cys34-HSA fraction were significantly correlated with the alternations of the plasma levels of advanced oxidized protein products, an oxidative stress marker for proteins. The binding ability of endogenous substances (bilirubin and tryptophan and drugs (warfarin and diazepam to HSA purified from chronic liver disease patients were significantly suppressed but significantly improved by BCAA supplementation. Interestingly, the changes in this physiological function of HSA in chronic liver disease were correlated with the Cys-Cys34-HSA fraction. In conclusion, ESI-TOFMS is a suitable high throughput method for the rapid and sensitive quantification of Cys-Cys34-HSA in a large number of samples for evaluating oxidative stress related chronic disease progression or in response to a treatment.

  5. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein

    International Nuclear Information System (INIS)

    Zhang, Xinsheng; Wallace, Olivia L.; Domi, Arban; Wright, Kevin J.; Driscoll, Jonathan; Anzala, Omu; Sanders, Eduard J.; Kamali, Anatoli; Karita, Etienne; Allen, Susan; Fast, Pat; Gilmour, Jill; Price, Matt A.; Parks, Christopher L.

    2015-01-01

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. - Highlights: • Screened 146 serum samples for measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb). • MV nAb is prevalent in the sera. • CDV neutralizing activity is generally low or absent and when detected it is present in sera with high MV nAb titers. • A neutralization-resistant CDV mutant was isolated using human serum selection. • A mutation was identified in the receptor-binding region of CDV hemagglutinin protein that confers the neutralization resistance

  6. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xinsheng, E-mail: xzhang@iavi.org [AIDS Vaccine Design and Development Laboratory, International AIDS Vaccine Initiative (IAVI), Brooklyn, NY (United States); Molecular and Cellular Biology Program, State University of New York, Brooklyn, NY (United States); Wallace, Olivia L.; Domi, Arban; Wright, Kevin J.; Driscoll, Jonathan [AIDS Vaccine Design and Development Laboratory, International AIDS Vaccine Initiative (IAVI), Brooklyn, NY (United States); Anzala, Omu [Kenya AIDS Vaccine Initiative (KAVI)-Institute of Clinical Research, Nairobi (Kenya); Sanders, Eduard J. [Centre for Geographic Medicine Research, Kenya Medical Research Institute (KEMRI), Kilifi, Kenya & Centre for Clinical Vaccinology and Tropical Medicine, University of Oxford, Headington (United Kingdom); Kamali, Anatoli [MRC/UVRI Uganda Virus Research Unit on AIDS, Masaka and Entebbe (Uganda); Karita, Etienne [Projet San Francisco, Kigali (Rwanda); Allen, Susan [Department of Pathology and Laboratory Medicine, Emory University, Atlanta, GA (United States); Fast, Pat [Department of Medical Affairs, International AIDS Vaccine Initiative, NY, NY (United States); Gilmour, Jill [Human Immunology Laboratory, International AIDS Vaccine Initiative, London (United Kingdom); Price, Matt A. [Department of Medical Affairs, International AIDS Vaccine Initiative, NY, NY (United States); Department of Epidemiology and Biostatistics, University of California at San Francisco, San Francisco, CA (United States); Parks, Christopher L. [AIDS Vaccine Design and Development Laboratory, International AIDS Vaccine Initiative (IAVI), Brooklyn, NY (United States); Molecular and Cellular Biology Program, State University of New York, Brooklyn, NY (United States)

    2015-08-15

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. - Highlights: • Screened 146 serum samples for measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb). • MV nAb is prevalent in the sera. • CDV neutralizing activity is generally low or absent and when detected it is present in sera with high MV nAb titers. • A neutralization-resistant CDV mutant was isolated using human serum selection. • A mutation was identified in the receptor-binding region of CDV hemagglutinin protein that confers the neutralization resistance.

  7. High sensitivity thermal sensors on insulating diamond

    Energy Technology Data Exchange (ETDEWEB)

    Job, R. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Denisenko, A.V. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Zaitsev, A.M. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices; Melnikov, A.A. [Belarussian State Univ., Minsk (Belarus). HEII and FD; Werner, M. [VDI/VDE-IT, Teltow (Germany); Fahrner, W.R. [Fernuniversitaet Hagen (Gesamthochschule) (Germany). Electron. Devices

    1996-12-15

    Diamond is a promising material to develop sensors for applications in harsh environments. To increase the sensitivity of diamond temperature sensors the effect of thermionic hole emission (TE) over an energetic barrier formed in the interface between highly boron-doped p-type and intrinsic insulating diamond areas has been suggested. To study the TE of holes a p-i-p diode has been fabricated and analyzed by electrical measurements in the temperature range between 300 K and 700 K. The experimental results have been compared with numerical simulations of its electrical characteristics. Based on a model of the thermionic emission of carriers into an insulator it has been suggested that the temperature sensitivity of the p-i-p diode on diamond is strongly affected by the re-emission of holes from a group of donor-like traps located at a level of 0.7-1.0 eV above the valence band. The mechanism of thermal activation of the current includes a spatial redistribution of the potential, which results in the TE regime from a decrease of the immobilized charge of the ionized traps within the i-zone of the diode and the correspondent lowering of the forward biased barrier. The characteristics of the p-i-p diode were studied with regard to temperature sensor applications. The temperature coefficient of resistance (TCR=-0.05 K{sup -1}) for temperatures above 600 K is about four times larger than the maximal attainable TCR for conventional boron-doped diamond resistors. (orig.)

  8. Quantitative proteomic analysis for high-throughput screening of differential glycoproteins in hepatocellular carcinoma serum

    International Nuclear Information System (INIS)

    Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing

    2015-01-01

    Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC

  9. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  10. Pretreated high lipid serum method and its significance before determine INS C-P by RIA

    International Nuclear Information System (INIS)

    Wan Guangxia; Zhu Liqiang; Wu Yufang

    2004-01-01

    The method of predigest high lipid serum before determine INS and C-P for elimination of the high lipid in serum was studied. The specimen was divided into two groups, one was directly tested, the other was pretreated, then determined(including INS and QC of serum, normal and high lipid serum, pretreating serum). The results were compared by examine and analysed correlatively. Results show that INS and C-P of the specimens pretreated by PEG, were no statistic difference in relation to direct tested (P>0.05) and those were close correlatively (P<0.001) in normal. The results of high lipid serum after the specimens were predigest by PEG were marked by decrease in relation to direct tested (P<0.001). High lipid and INS antibody were eliminated by PEG so that was increased the results nicety. (authors)

  11. The Tick Salivary Protein Salp15 Inhibits the Killing of Serum-Sensitive Borrelia burgdorferi Sensu Lato Isolates▿

    OpenAIRE

    Schuijt, Tim J.; Hovius, Joppe W. R.; van Burgel, Nathalie D.; Ramamoorthi, Nandhini; Fikrig, Erol; van Dam, Alje P.

    2008-01-01

    Borrelia burgdorferi, the agent of Lyme disease, is transmitted by ticks. During transmission from the tick to the host, spirochetes are delivered with tick saliva, which contains the salivary protein Salp15. Salp15 has been shown to protect spirochetes against B. burgdorferi-specific antibodies. We now show that Salp15 from both Ixodes ricinus and Ixodes scapularis protects serum-sensitive isolates of Borrelia burgdorferi sensu lato against complement-mediated killing. I. ricinus Salp15 show...

  12. Highly sensitive detection of a current ripple

    International Nuclear Information System (INIS)

    Aoki, Takashi; Gushiken, Tutomu; Nishikigouri, Kazutaka; Kumada, Masayuki.

    1996-01-01

    In the HIMAC, there are six thyristor-controlled power sources for driving two synchrotrons. These power sources are the three-output terminal power sources which are equipped with positive output, negative output and neutral point for the common mode countermeasures. As electromagnet circuits are connected to the three-output terminal power sources, those are three-line type. In the inside of the power source circuits controlled by thyristors, there is the oscillation peculiar to the power sources, and the variation of voltage induces current spikes. This time, in order to assess the results of the common mode countermeasures in the power source and electromagnet circuits, as one method of cross-check, it is considered that since electromagnet current flows being divided to the bridging resistance and the coil, if attention is paid to the current on bridging resistance side, the ripple components of common mode and normal mode can be detected with high sensitivity, and this was verified. The present state of heightening the performance of synchrotron power sources is explained. The cross-check of the method of assessing the performance of electromagnet power sources is reported. The method of measuring ripple current and the results of the measurement are reported. (K.I.)

  13. Development of high sensitivity radon detectors

    CERN Document Server

    Takeuchi, Y; Kajita, T; Tasaka, S; Hori, H; Nemoto, M; Okazawa, H

    1999-01-01

    High sensitivity detectors for radon in air and in water have been developed. We use electrostatic collection and a PIN photodiode for these detectors. Calibration systems have been also constructed to obtain collection factors. As a result of the calibration study, the absolute humidity dependence of the radon detector for air is clearly observed in the region less than about 1.6 g/m sup 3. The calibration factors of the radon detector for air are 2.2+-0.2 (counts/day)/(mBq/m sup 3) at 0.08 g/m sup 3 and 0.86+-0.06 (counts/day)/(mBq/m sup 3) at 11 g/m sup 3. The calibration factor of the radon detector for water is 3.6+-0.5 (counts/day)/(mBq/m sup 3). The background level of the radon detector for air is 2.4+-1.3 counts/day. As a result, one standard deviation excess of the signal above the background of the radon detector for air should be possible for 1.4 mBq/m sup 3 in a one-day measurement at 0.08 g/m sup 3.

  14. Tubule urate and PAH transport: sensitivity and specificity of serum protein inhibition

    International Nuclear Information System (INIS)

    Grantham, J.J.; Kennedy, J.; Cowley, B.

    1987-01-01

    Macromolecules in rabbit serum inhibit the cellular uptake and transepithelial secretion of [ 14 C]urate and p-[ 3 H]aminohippurate ([ 3 H]PAH) in rabbit S 2 proximal tubule segments. To understand better the potential role these inhibitors may have in the regulation of renal organic anion excretion, the authors examined the specificity and relative inhibitory effects on tubule urate and PAH transport of albumin and γ-globulin, the major inhibitory proteins in rabbit serum. Native rabbit serum markedly inhibited the cellular accumulation or urate and PAH by isolated nonperfused segments. Urate and PAH transport was also inhibited by bovine serum, human serum, Cohn-fractionated rabbit albumin, and rabbit γ-globulin, but not by Cohn-fractionated bovine serum albumin. α-Lactalbumin and β-lactoglobulin, derived from milk, also inhibited urate and PAH transport, but to a lesser extent than albumin and γ-globulin. The transport inhibitory effects of proteins were independent of their binding to urate and PAH. Unidirectional influx and the steady-state intracellular accumulation of urate and PAH in suspensions of proximal tubules were decreased by rabbit serum proteins, suggesting that these inhibitors act on the external face of the cells to diminish the uptake of the organic anions. These studies indicate that the principal plasma proteins (albumin and γ-globulin) significantly inhibit urate and PAH transporters in the basolateral membranes of S 2 proximal tubules. They suggest that circulating plasma proteins that can penetrate the basement membrane of proximal tubules may directly modulate the renal excretion of urate and PAH

  15. High serum lactate as an adjunct in the early prediction of anastomotic leak following oesophagectomy.

    Science.gov (United States)

    Ip, B; Ng, K T; Packer, S; Paterson-Brown, S; Couper, G W

    2017-10-01

    Anastomotic leak (AL) following oesophagectomy carries a high mortality and morbidity. Early detection and intervention is required for a successful outcome. We have examined the role of a high postoperative serum lactate in predicting which patients are at risk of developing an anastomotic leak(AL). All patients who underwent transthoracic oesophagectomy over a 3-year period were identified from a prospectively collected database. Medical records were reviewed to identify the highest serum lactate recorded from blood gas analysis over each 24hr post-operative period. Patients who underwent transhiatal and left thoraco-abdominal oesophagectomies were excluded. Patients who developed a chyle leak were excluded. Of a total of 136 oesophagectomies included for analysis, 18 developed an AL (13.2%). Of these patients, 10 underwent thoracoscopic oesophageal mobilization with cervical anastomosis and the rest an Ivor Lewis procedure. Predictive factors for AL included neoadjuvant chemotherapy (15/18 83.3% vs 55/118 46.6% p = 0.0046) and number of positive lymph nodes (mean 4.2 vs control mean 2.3 p = 0.045). Overall net fluid balance was comparable between the 2 groups, although AL patients received slightly more fluid on Day 3. High lactate levels on days 1-3 were associated with an AL. Using a Day 2 lactate of 1.7 mmol/L, the sensitivity of predicting AL was 72% and specificity 88%. The mean lag time using existing diagnostic modalities was 7.9 days. A serum lactate of >1.7 mmol/l on day 2 should raise the possibility of a potential AL. Such patients should be selected for more intensive monitoring, optimization and selective gastroscopy. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. High serum alanine aminotransferase is associated with the risk of colorectal adenoma in Korean men.

    Science.gov (United States)

    Moon, Chang Mo; Yun, Kyung Eun; Ryu, Seungho; Chang, Yoosoo; Park, Dong Il

    2017-07-01

    An elevated alanine aminotransferase (ALT) is frequently observed in subjects with metabolic syndrome, which is associated with the risk of colorectal adenoma (CRA). However, the relationship between ALT and CRA remains unclear. Therefore, we aimed to investigate whether high serum ALT is associated with the risk of CRA in a metabolically healthy population. We conducted this cross-sectional study in 27,717 asymptomatic Korean adults who underwent a health checkup. Subjects were categorized as adenoma-free, hyperplastic polyp, low-risk adenoma, or high-risk adenoma. High-risk adenoma was defined as three or more adenomas, any adenoma ≥ 10 mm, or adenoma with high-grade dysplasia or villous features. Among all participants, 10.3% and 1.5% of cases were categorized as low-risk and high-risk adenoma, respectively. In multivariate analyses adjusting for age, sex, body mass index, smoking habits, alcohol intake, regular exercise, aspirin and analgesics use, family history of colon cancer, education level, fatty liver, high-sensitivity C reactive protein, homeostasis model assessment of insulin resistance, total cholesterol, and triglyceride, an increase in ALT was positively associated with the prevalence of low-risk and high-risk adenoma (P for trend = 0.029 and 0.027, respectively). The highest quartile group of ALT level showed a significantly increased prevalence in low-risk (odds ratio, 1.17) and high-risk adenoma (odds ratio, 1.48) groups compared with the lowest quartile group. This phenomenon persisted in the subgroup analysis in men, but not in women. In the asymptomatic healthy population, high serum ALT is significantly associated with the risk of CRA. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  17. Serum leptin is correlated to high turnover in osteoporosis.

    Science.gov (United States)

    Hipmair, Gunter; Böhler, Nikolaus; Maschek, Wilma; Soriguer, Federico; Rojo-Martínez, Gemma; Schimetta, Wolfgang; Pichler, Robert

    2010-01-01

    Clinical data have suggested that obesity protects against osteoporosis. Leptin, mainly secreted by white adipose tissue, might be involved by mediating an effect on bone metabolism. This study was conducted to investigate a possible relationship of leptin and bone turn-over in postmenopausal women with osteoporosis. We measured bone mineral density (BMD), serum leptin levels and markers of bone metabolism, including osteocalcin and cross-laps in 44 patients with osteoporosis. The main group consisted of 32 postmenopausal women. Mean serum leptin was 13.1 microg/L and showed no statistically significant difference to the levels measured in a collective of normal persons adjusted for age and BMI. When related to serum cross-laps as markers of bone resorption, a positive correlation (posteoporosis.

  18. A sensitive radioimmunoassay for measurements of 3,3'- diiodothyronine in unextracted serum

    International Nuclear Information System (INIS)

    Laurberg, P.

    1978-01-01

    A radioimmunoassay for measurements of 3,3'-diiodothyronine (3,3'-T2) in unextracted serum is described. Antisera to 3,3'-T2 were produced by immunization of rabbits with 3,3'-T2 coupled to human serum albumin. Scatchard plot analysis of the chosen antiserum gave an effective equilibrium constant of 1.1x 10 11 l/mol. The 3,3'-T2 binding capacity in undiluted serum was calculated to be 9.1 mmol/m. Monolabelled ( 125 I)3,3'T2 having a specific activity of 3800 mCi/mg was synthetized from 3-monoiodothyronine. The lowest concentration of standard inducing a consistent fall in per cent bound ( 125 I)3,3'-T2 was 6.0 pmol/l (0.24fmol/tube). Triiodothyronine (T3) cross-reacted significantly in the assay. At 50% inhibition of binding of ( 125 I)3,3'-T2, the cross-reaction was 0.29% (mol/mol), but at the low physiological concentrations of T3 it amounted to approximately 1%. T3 cross-reaction was corrected for in every assay. The interference of 3,3'-T2 binding proteins in serum was precluded by adding 8-anilino-1-napthalenesulphonic acid (ANS). Mean 3,3'-T2 concentrations were 38.9 pmol/l in fourteen normal young females and 48.9 pmol/l in fifteen normal young males. When 3,3'-T2 was measured(1) in extracts of serum, (2) in assays where T3 was added to standards in amounts equivalent to those present in the samples and T3 correction omitted, and (3) using a different 3,3'-T2 antibody, similar levels of 3,3'-T2 were found in normal serum. (Auth.)

  19. Serum-free Erythroid Differentiation for Efficient Genetic Modification and High-Level Adult Hemoglobin Production.

    Science.gov (United States)

    Uchida, Naoya; Demirci, Selami; Haro-Mora, Juan J; Fujita, Atsushi; Raines, Lydia N; Hsieh, Matthew M; Tisdale, John F

    2018-06-15

    In vitro erythroid differentiation from primary human cells is valuable to develop genetic strategies for hemoglobin disorders. However, current erythroid differentiation methods are encumbered by modest transduction rates and high baseline fetal hemoglobin production. In this study, we sought to improve both genetic modification and hemoglobin production among human erythroid cells in vitro . To model therapeutic strategies, we transduced human CD34 + cells and peripheral blood mononuclear cells (PBMCs) with lentiviral vectors and compared erythropoietin-based erythroid differentiation using fetal-bovine-serum-containing media and serum-free media. We observed more efficient transduction (85%-93%) in serum-free media than serum-containing media (20%-69%), whereas the addition of knockout serum replacement (KSR) was required for serum-free media to promote efficient erythroid differentiation (96%). High-level adult hemoglobin production detectable by electrophoresis was achieved using serum-free media similar to serum-containing media. Importantly, low fetal hemoglobin production was observed in the optimized serum-free media. Using KSR-containing, serum-free erythroid differentiation media, therapeutic adult hemoglobin production was detected at protein levels with β-globin lentiviral transduction in both CD34 + cells and PBMCs from sickle cell disease subjects. Our in vitro erythroid differentiation system provides a practical evaluation platform for adult hemoglobin production among human erythroid cells following genetic manipulation.

  20. False high level in total bilirubin estimation in nonicteric serum

    African Journals Online (AJOL)

    estimation of total bilirubin by DiaSys and Randox reagents along with simultaneous re-estimation by Roche reagents in ... been used mainly due to slightly lower cost in ... MATERIALS AND METHODS ... air-conditioned laboratory overnight. ..... Elevated IgG causing spurious elevation in serum total bilirubin assay. Asia.

  1. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  2. Serum complement changes during double-blind food challenges in children with a history of food sensitivity.

    Science.gov (United States)

    Martin, M E; Guthrie, L A; Bock, S A

    1984-04-01

    Serum levels of C3, C4, factor B, properdin, total hemolytic complement and alternative-pathway hemolytic activity were measured before and after double-blind food challenge in 23 children with impressive histories of adverse reactions to foods. The 23 subjects had 11 positive food challenges and 12 negative food challenges. Nine patients with reagin-mediated positive food challenges showed increases in all six complement assays after double-blind food challenge, while the group with negative food challenges showed decreases in five of the six assays. The difference between the two groups for complement changes after double-blind food challenge was significant only for the alternative-pathway assay. Individual subject analysis revealed markedly heterogeneous changes in direction and magnitude within both groups for all complement assays. Therefore, it is concluded that measurement of serum complement levels is not a useful test for the clinical evaluation of a patient with suspected food sensitivity.

  3. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  4. Environmental Sensitivity in Children: Development of the Highly Sensitive Child Scale and Identification of Sensitivity Groups

    Science.gov (United States)

    Pluess, Michael; Assary, Elham; Lionetti, Francesca; Lester, Kathryn J.; Krapohl, Eva; Aron, Elaine N.; Aron, Arthur

    2018-01-01

    A large number of studies document that children differ in the degree they are shaped by their developmental context with some being more sensitive to environmental influences than others. Multiple theories suggest that "Environmental Sensitivity" is a common trait predicting the response to negative as well as positive exposures.…

  5. High sensitivity optical measurement of skin gloss

    NARCIS (Netherlands)

    Ezerskaia, A.; Ras, Arno; Bloemen, Pascal; Pereira, S.F.; Urbach, Paul; Varghese, Babu

    2017-01-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between

  6. Is a high serum copper concentration a risk factor for implantation failure?

    Science.gov (United States)

    Matsubayashi, Hidehiko; Kitaya, Kotaro; Yamaguchi, Kohei; Nishiyama, Rie; Takaya, Yukiko; Ishikawa, Tomomoto

    2017-08-10

    Copper-containing contraceptive devices may deposit copper ions in the endometrium, resulting in implantation failure. The deposition of copper ions in many organs has been reported in patients with untreated Wilson's disease. Since these patients sometimes exhibit subfertility and/or early pregnancy loss, copper ions were also considered to accumulate in the uterine endometrium. Wilson's disease patients treated with zinc successfully delivered babies because zinc interfered with the absorption of copper from the gastrointestinal tract. These findings led to the hypothesis that infertile patients with high serum copper concentrations may have implantation failure due to the excess accumulation of copper ions. The relationship between implantation (pregnancy) rates and serum copper concentrations has not yet been examined. The Japanese government recently stated that actual copper intake was higher among Japanese than needed. Therefore, the aim of the present study was to investigate whether serum copper concentrations are related to the implantation (pregnancy) rates of human embryos in vivo. We included 269 patients (age copper, and zinc concentrations were measured 16 days after the first date of progesterone replacement. We compared 96 women who were pregnant without miscarriage at 10 weeks of gestation (group P) and 173 women who were not pregnant (group NP). No significant differences were observed in age or BMI between the groups. Copper concentrations were significantly higher in group NP (average 193.2 μg/dL) than in group P (average 178.1 μg/dL). According to the area under the curve (AUC) on the receiver operating characteristic curve for the prediction of clinical pregnancy rates, the Cu/Zn ratio (AUC 0.64, 95% CI 0.54-0.71) was a better predictor than copper or zinc. When we set the cut-off as 1.59/1.60 for the Cu/Zn ratio, sensitivity, specificity, the positive predictive value, and negative predictive value were 0.98, 0.29, 0.71, and 0

  7. Serum irisin and myostatin levels after 2 weeks of high-altitude climbing.

    Directory of Open Access Journals (Sweden)

    Ewa Śliwicka

    Full Text Available Exposure to high-altitude hypoxia causes physiological and metabolic adaptive changes by disturbing homeostasis. Hypoxia-related changes in skeletal muscle affect the closely interconnected energy and regeneration processes. The balance between protein synthesis and degradation in the skeletal muscle is regulated by several molecules such as myostatin, cytokines, vitamin D, and irisin. This study investigates changes in irisin and myostatin levels in male climbers after a 2-week high-altitude expedition, and their association with 25(OHD and indices of inflammatory processes. The study was performed in 8 men aged between 23 and 31 years, who participated in a 2-week climbing expedition in the Alps. The measurements of body composition and serum concentrations of irisin, myostatin, 25(OHD, interleukin-6, myoglobin, high-sensitivity C-reactive protein, osteoprotegerin, and high-sensitivity soluble receptor activator of NF-κB ligand (sRANKL were performed before and after expedition. A 2-week exposure to hypobaric hypoxia caused significant decrease in body mass, body mass index (BMI, free fat mass and irisin, 25-Hydroxyvitamin D levels. On the other hand, significant increase in the levels of myoglobin, high-sensitivity C-reactive protein, interleukin-6, and osteoprotegerin were noted. The observed correlations of irisin with 25(OHD levels, as well as myostatin levels with inflammatory markers and the OPG/RANKL ratio indicate that these myokines may be involved in the energy-related processes and skeletal muscle regeneration in response to 2-week exposure to hypobaric hypoxia.

  8. Serum irisin and myostatin levels after 2 weeks of high-altitude climbing.

    Science.gov (United States)

    Śliwicka, Ewa; Cisoń, Tomasz; Kasprzak, Zbigniew; Nowak, Alicja; Pilaczyńska-Szcześniak, Łucja

    2017-01-01

    Exposure to high-altitude hypoxia causes physiological and metabolic adaptive changes by disturbing homeostasis. Hypoxia-related changes in skeletal muscle affect the closely interconnected energy and regeneration processes. The balance between protein synthesis and degradation in the skeletal muscle is regulated by several molecules such as myostatin, cytokines, vitamin D, and irisin. This study investigates changes in irisin and myostatin levels in male climbers after a 2-week high-altitude expedition, and their association with 25(OH)D and indices of inflammatory processes. The study was performed in 8 men aged between 23 and 31 years, who participated in a 2-week climbing expedition in the Alps. The measurements of body composition and serum concentrations of irisin, myostatin, 25(OH)D, interleukin-6, myoglobin, high-sensitivity C-reactive protein, osteoprotegerin, and high-sensitivity soluble receptor activator of NF-κB ligand (sRANKL) were performed before and after expedition. A 2-week exposure to hypobaric hypoxia caused significant decrease in body mass, body mass index (BMI), free fat mass and irisin, 25-Hydroxyvitamin D levels. On the other hand, significant increase in the levels of myoglobin, high-sensitivity C-reactive protein, interleukin-6, and osteoprotegerin were noted. The observed correlations of irisin with 25(OH)D levels, as well as myostatin levels with inflammatory markers and the OPG/RANKL ratio indicate that these myokines may be involved in the energy-related processes and skeletal muscle regeneration in response to 2-week exposure to hypobaric hypoxia.

  9. High sensitivity optical measurement of skin gloss

    OpenAIRE

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F.; Urbach, H. Paul; Varghese, Babu

    2017-01-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the...

  10. Highly sensitive ratiometric detection of heparin and its oversulfated chondroitin sulfate contaminant by fluorescent peptidyl probe.

    Science.gov (United States)

    Mehta, Pramod Kumar; Lee, Hyeri; Lee, Keun-Hyeung

    2017-05-15

    The selective and sensitive detection of heparin, an anticoagulant in clinics as well as its contaminant oversulfated chondroitin sulfate (OSCS) is of great importance. We first reported a ratiometric sensing method for heparin as well as OSCS contaminants in heparin using a fluorescent peptidyl probe (Pep1, pyrene-GSRKR) and heparin-digestive enzyme. Pep1 exhibited a highly sensitive ratiometric response to nanomolar concentration of heparin in aqueous solution over a wide pH range (2~11) and showed highly selective ratiometric response to heparin among biological competitors such as hyaluronic acid and chondroitin sulfate. Pep1 showed a linear ratiometric response to nanomolar concentrations of heparin in aqueous solutions and in human serum samples. The detection limit for heparin was calculated to be 2.46nM (R 2 =0.99) in aqueous solutions, 2.98nM (R 2 =0.98) in 1% serum samples, and 3.43nM (R 2 =0.99) in 5% serum samples. Pep1 was applied to detect the contaminated OSCS in heparin with heparinase I, II, and III, respectively. The ratiometric sensing method using Pep1 and heparinase II was highly sensitive, fast, and efficient for the detection of OSCS contaminant in heparin. Pep1 with heparinase II could detect as low as 0.0001% (w/w) of OSCS in heparin by a ratiometric response. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  12. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  13. High-Flux Hemodialysis and High-Volume Hemodiafiltration Improve Serum Calcification Propensity.

    Directory of Open Access Journals (Sweden)

    Marijke Dekker

    Full Text Available Calciprotein particles (CPPs may play an important role in the calcification process. The calcification propensity of serum (T50 is highly predictive of all-cause mortality in chronic kidney disease patients. Whether T50 is therapeutically improvable, by high-flux hemodialysis (HD or hemodiafiltration (HDF, has not been studied yet.We designed a cross-sectional single center study, and included stable prevalent in-center dialysis patients on HD or HDF. Patients were divided into two groups based on dialysis modality, were on a thrice-weekly schedule, had a dialysis vintage of > 3 months and vascular access providing a blood flow rate > 300 ml/min. Calcification propensity of serum was measured by the time of transformation from primary to secondary CPP (T50 test, by time-resolved nephelometry.We included 64 patients, mean convective volume was 21.7L (SD 3.3L. In the pooled analysis, T50 levels increased in both the HD and HDF group with pre- and post-dialysis (mean (SD of 244(64 - 301(57 and 253(55 - 304(61 min respectively (P = 0.43(HD vs. HDF. The mean increase in T50 was 26.29% for HD and 21.97% for HDF patients (P = 0.61 (HD vs. HDF. The delta values (Δ of calcium, phosphate and serum albumin were equal in both groups. Baseline T50 was negatively correlated with phosphate, and positively correlated with serum magnesium and fetuin-A. The ΔT50 was mostly influenced by Δ phosphate (r = -0.342; P = 0.002 HD and r = -0.396; P<0.001 HDF in both groups.HD and HDF patients present with same baseline T50 calcification propensity values pre-dialysis. Calcification propensity is significantly improved during both HD and HDF sessions without significant differences between both modalities.

  14. Relationship between high serum ferritin level and glaucoma in a South Korean population: the Kangbuk Samsung health study.

    Science.gov (United States)

    Gye, Hyo Jung; Kim, Joon Mo; Yoo, Chungkwon; Shim, Seong Hee; Won, Yu Sam; Sung, Ki Chul; Lee, Mi Yeon; Park, Ki Ho

    2016-12-01

    To investigate the association between serum ferritin levels and glaucoma in a South Korean population. This retrospective cross-sectional study included 164 029 subjects who underwent screening at Kangbuk Samsung Hospital Health Screening Center between August 2012 and July 2013. All subjects underwent a physical examination, answered sociodemographic and behavioural questions, and provided samples for laboratory analyses. A digital fundus photograph of both eyes was taken, and all photographs were reviewed by ophthalmologists. The ophthalmologists determined if an eye had glaucoma based on criteria set forth by the International Society of Geographical and Epidemiological Ophthalmology and the appearance of the retinal nerve fibre layer and optic disc. The mean serum ferritin level was 56.98 ng/mL in women and 223.82 ng/mL in men. After adjusting for age, serum iron, total iron-binding capacity (TIBC), transferrin saturation, white blood cell (WBC) count, high-sensitivity C-reactive protein (HsCRP) and total vitamin D level, males in the highest quartile for serum ferritin level had a higher OR for glaucoma than males in the lowest quartile (OR=1.176, 95% CI 1.030 to 1.342, p=0.016); we did not observe this relationship among women. Other markers of iron metabolism, such as iron level, transferrin saturation and TIBC, and inflammation measures, including WBC, HsCRP and total vitamin D, were not associated with glaucoma. High serum ferritin level was associated with a high risk of glaucoma in men, but not in women. Because serum ferritin is related to oxidative stress and inflammation, it might play a role in glaucoma development. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Differential expression of miRNAs in the serum of patients with high-risk oral lesions

    International Nuclear Information System (INIS)

    MacLellan, Sara Ann; Lawson, James; Baik, Jonathan; Guillaud, Martial; Poh, Catherine Fang-Yeu; Garnis, Cathie

    2012-01-01

    Oral cancer is one of the most commonly diagnosed cancers worldwide. Disease is often diagnosed at later stages, which is associated with a poor 5-year survival rate and a high rate of local recurrence. MicroRNAs (miRNAs), a group of small, noncoding RNAs, can be isolated from blood serum samples and have demonstrated utility as biomarkers in multiple cancer types. The aim of this study was to examine the expression profiles of circulating miRNAs in the serum of patients with high-risk oral lesions (HRLs; oral cancer or carcinoma in situ) and to explore their utility as potential oral cancer biomarkers. Global serum miRNA profiles were generated using quantitative PCR method from 1) patients diagnosed with HRLs and undergoing intent-to-cure surgical treatment (N = 30) and 2) a demographically matched, noncancer control group (N = 26). We next honed our list of serum miRNAs associated with disease by reducing the effects of interpatient variability; we compared serum miRNA profiles from samples taken both before and after tumor resections (N = 10). Based on these analyses, fifteen miRNAs were significantly upregulated and five were significantly downregulated based on presence of disease (minimum fold-change >2 in at least 50% of samples, P < 0.05, permutation). Five of these miRNAs (miR-16, let-7b, miR-338-3p, miR-223, and miR-29a) yielded an area under the ROC curve (AUC) >0.8, suggesting utility as noninvasive biomarkers for detection of oral cancer or high-grade lesions. Combining these serum miRNA profiles with other screening techniques could greatly improve the sensitivity in oral cancer detection

  16. Added sensitivity of component-resolved diagnosis in hymenoptera venom-allergic patients with elevated serum tryptase and/or mastocytosis

    DEFF Research Database (Denmark)

    Michel, J B; Brockow, K; Darsow, U

    2016-01-01

    BACKGROUND: Anaphylaxis caused by hymenoptera venom allergy is associated with elevation of baseline serum tryptase (sBT) and/or mastocytosis in about 5% of patients. Up to now, no information has become available on single venom allergen sIgE reactivity and the usefulness of component......-resolved approaches to diagnose this high-risk patient group. To address the component-resolved sIgE sensitization pattern and diagnostic sensitivity in hymenoptera venom-allergic patients with elevated sBT levels and/or mastocytosis, a panel of yellow jacket and honeybee venom allergens was applied on a widely used...... IgE immunoassay platform. METHODS: Fifty-three patients with mastocytosis and/or elevated sBT tryptase level and systemic reactions to hymenoptera venoms were analyzed for their IgE reactivity to recombinant yellow jacket and honeybee venom allergens by Immulite3 g. RESULTS: sIgE reactivity to Ves v...

  17. INFLUENCE OF HIGH CORTISOL DOSES UPON THE SERUM IMMUNOGLOBULIN LEVEL

    OpenAIRE

    Voja Pavlovic; Zoran Pavlovic

    2001-01-01

    The effects of Cortisol upon the serum immunoglobulin concentration areexamined. The experiment involved male guinea pigs of the body weight from 300 to400 g that were nonnally fed and lived under the common laboratory conditions. Theguinea pigs were divided into an experimental and a control group. The experimentalgroup's guinea pigs were given every day (in a 6 days' period) a subcutaneous dose of80 g of corti sol/kg/per day, while the control group ones were given only one ml ofthe physiol...

  18. High sensitivity optical measurement of skin gloss.

    Science.gov (United States)

    Ezerskaia, Anna; Ras, Arno; Bloemen, Pascal; Pereira, Silvania F; Urbach, H Paul; Varghese, Babu

    2017-09-01

    We demonstrate a low-cost optical method for measuring the gloss properties with improved sensitivity in the low gloss regime, relevant for skin gloss properties. The gloss estimation method is based on, on the one hand, the slope of the intensity gradient in the transition regime between specular and diffuse reflection and on the other on the sum over the intensities of pixels above threshold, derived from a camera image obtained using unpolarized white light illumination. We demonstrate the improved sensitivity of the two proposed methods using Monte Carlo simulations and experiments performed on ISO gloss calibration standards with an optical prototype. The performance and linearity of the method was compared with different professional gloss measurement devices based on the ratio of specular to diffuse intensity. We demonstrate the feasibility for in-vivo skin gloss measurements by quantifying the temporal evolution of skin gloss after application of standard paraffin cream bases on skin. The presented method opens new possibilities in the fields of cosmetology and dermatopharmacology for measuring the skin gloss and resorption kinetics and the pharmacodynamics of various external agents.

  19. Improved Immunoassay Sensitivity in Serum as a Result of Polymer-Entrapped Quantum Dots: 'Papaya Particles'

    NARCIS (Netherlands)

    Ranzoni, A.; den Hamer, A.; Karoli, T.; Buechler, J.; Cooper, M.A.

    2015-01-01

    Fluorescent labels are widely employed in biomarker quantification and diagnostics, however they possess narrow Stokes shifts and can photobleach, limiting multiplexed detection applications and compromising sensitivity. In contrast, quantum dots do not photobleach and have much wider Stokes shifts,

  20. The selectively bred high alcohol sensitivity (HAS) and low alcohol sensitivity (LAS) rats differ in sensitivity to nicotine.

    Science.gov (United States)

    de Fiebre, NancyEllen C; Dawson, Ralph; de Fiebre, Christopher M

    2002-06-01

    Studies in rodents selectively bred to differ in alcohol sensitivity have suggested that nicotine and ethanol sensitivities may cosegregate during selective breeding. This suggests that ethanol and nicotine sensitivities may in part be genetically correlated. Male and female high alcohol sensitivity (HAS), control alcohol sensitivity, and low alcohol sensitivity (LAS) rats were tested for nicotine-induced alterations in locomotor activity, body temperature, and seizure activity. Plasma and brain levels of nicotine and its primary metabolite, cotinine, were measured in these animals, as was the binding of [3H]cytisine, [3H]epibatidine, and [125I]alpha-bungarotoxin in eight brain regions. Both replicate HAS lines were more sensitive to nicotine-induced locomotor activity depression than the replicate LAS lines. No consistent HAS/LAS differences were seen on other measures of nicotine sensitivity; however, females were more susceptible to nicotine-induced seizures than males. No HAS/LAS differences in nicotine or cotinine levels were seen, nor were differences seen in the binding of nicotinic ligands. Females had higher levels of plasma cotinine and brain nicotine than males but had lower brain cotinine levels than males. Sensitivity to a specific action of nicotine cosegregates during selective breeding for differential sensitivity to a specific action of ethanol. The differential sensitivity of the HAS/LAS rats is due to differences in central nervous system sensitivity and not to pharmacokinetic differences. The differential central nervous system sensitivity cannot be explained by differences in the numbers of nicotinic receptors labeled in ligand-binding experiments. The apparent genetic correlation between ethanol and nicotine sensitivities suggests that common genes modulate, in part, the actions of both ethanol and nicotine and may explain the frequent coabuse of these agents.

  1. High serum creatinine nonlinearity: a renal vital sign?

    Science.gov (United States)

    Palant, Carlos E; Chawla, Lakhmir S; Faselis, Charles; Li, Ping; Pallone, Thomas L; Kimmel, Paul L; Amdur, Richard L

    2016-08-01

    Patients with chronic kidney disease (CKD) may have nonlinear serum creatinine concentration (SC) trajectories, especially as CKD progresses. Variability in SC is associated with renal failure and death. However, present methods for measuring SC variability are unsatisfactory because they blend information about SC slope and variance. We propose an improved method for defining and calculating a patient's SC slope and variance so that they are mathematically distinct, and we test these methods in a large sample of US veterans, examining the correlation of SC slope and SC nonlinearity (SCNL) and the association of SCNL with time to stage 4 CKD (CKD4) and death. We found a strong correlation between SCNL and rate of CKD progression, time to CKD4, and time to death, even in patients with normal renal function. We therefore argue that SCNL may be a measure of renal autoregulatory dysfunction that provides an early warning sign for CKD progression. Copyright © 2016 the American Physiological Society.

  2. Optimizing cationic and neutral lipids for efficient gene delivery at high serum content.

    Science.gov (United States)

    Chan, Chia-Ling; Ewert, Kai K; Majzoub, Ramsey N; Hwu, Yeu-Kuang; Liang, Keng S; Leal, Cecília; Safinya, Cyrus R

    2014-01-01

    Cationic liposome (CL)-DNA complexes are promising gene delivery vectors with potential application in gene therapy. A key challenge in creating CL-DNA complexes for application is that their transfection efficiency (TE) is adversely affected by serum. In particular, little is known about the effects of a high serum content on TE, even though this may provide design guidelines for application in vivo. We prepared CL-DNA complexes in which we varied the neutral lipid [1,2-dioleoyl-sn-glycerophosphatidylcholine, glycerol-monooleate (GMO), cholesterol], the headgroup charge and chemical structure of the cationic lipid, and the ratio of neutral to cationic lipid; we then measured the TE of these complexes as a function of serum content and assessed their cytotoxicity. We tested selected formulations in two human cancer cell lines (M21/melanoma and PC-3/prostate cancer). In the absence of serum, all CL-DNA complexes of custom-synthesized multivalent lipids show high TE. Certain combinations of multivalent lipids and neutral lipids, such as MVL5(5+)/GMO-DNA complexes or complexes based on the dendritic-headgroup lipid TMVLG3(8+) exhibited high TE both in the absence and presence of serum. Although their TE still dropped to a small extent in the presence of serum, it reached or surpassed that of benchmark commercial transfection reagents, particularly at a high serum content. Two-component vectors (one multivalent cationic lipid and one neutral lipid) can rival or surpass benchmark reagents at low and high serum contents (up to 50%, v/v). We propose guidelines for optimizing the serum resistance of CL-DNA complexes based on a given cationic lipid. Copyright © 2014 John Wiley & Sons, Ltd.

  3. A Sensitive Gold Nanoplasmonic SERS Quantitative Analysis Method for Sulfate in Serum Using Fullerene as Catalyst

    Directory of Open Access Journals (Sweden)

    Chongning Li

    2018-04-01

    Full Text Available Fullerene exhibited strong catalysis of the redox reaction between HAuCl4 and trisodium citrate to form gold nanoplasmon with a strong surface-enhanced Raman scattering (SERS effect at 1615 cm−1 in the presence of Vitoria blue B molecule probes. When fullerene increased, the SERS peak enhanced linearly due to formation of more AuNPs as substrate. Upon addition of Ba2+, Ba2+ ions adsorb on the fullerene surface to inhibit the catalysis of fullerene that caused the SERS peak decreasing. Analyte SO42− combined with Ba2+ to form stable BaSO4 precipitate to release free fullerene that the catalysis recovered, and the SERS intensity increased linearly. Thus, a new SERS quantitative analysis method was established for the detection of sulfate in serum samples, with a linear range of 0.03–3.4 μM.

  4. High-Sensitivity GaN Microchemical Sensors

    Science.gov (United States)

    Son, Kyung-ah; Yang, Baohua; Liao, Anna; Moon, Jeongsun; Prokopuk, Nicholas

    2009-01-01

    Systematic studies have been performed on the sensitivity of GaN HEMT (high electron mobility transistor) sensors using various gate electrode designs and operational parameters. The results here show that a higher sensitivity can be achieved with a larger W/L ratio (W = gate width, L = gate length) at a given D (D = source-drain distance), and multi-finger gate electrodes offer a higher sensitivity than a one-finger gate electrode. In terms of operating conditions, sensor sensitivity is strongly dependent on transconductance of the sensor. The highest sensitivity can be achieved at the gate voltage where the slope of the transconductance curve is the largest. This work provides critical information about how the gate electrode of a GaN HEMT, which has been identified as the most sensitive among GaN microsensors, needs to be designed, and what operation parameters should be used for high sensitivity detection.

  5. High Serum Pepsinogen I and beta Helicobacter pylori Infection Are Risk Factors for Aspirin-Induced Gastroduodenal Injury.

    Science.gov (United States)

    Shan, Jing; Lei, Hongjun; Shi, Wei; Sun, Xiaobin; Tang, Yu; Ren, Chunrong

    2018-01-01

    Whether gastric hyperchlorhydria and Helicobacter pylori infection contribute to aspirin-induced gastroduodenal injury still lacks evidence. Because serum pepsinogens (PGs) and gastrin-17 (G17) can reflect gastric acid secretion, this study intended to elucidate whether serum PGs, serum G17, and H. pylori infection are associated with aspirin-induced gastrointestinal injury. A total of 60 patients taking low-dose aspirin for more than 1 month were enrolled in this study. Serum PG I, PG II, and G17 were determined using ELISA. A 14C-urea breath test was used for the detection of an H. pylori infection. The modified Lanza score was used to evaluate the degree of gastroduodenal injury under endoscopy. The median serum PG I level was significantly higher in the intensive gastroduodenal injury (IGI) group compared to that in the mild gastroduodenal injury group (155.0 vs. 116.6 ng/mL, p = 0.006). The H. pylori infection rate was significantly higher in the IGI group (73 vs. 40%, p = 0.037). Receiver operator characteristic curves analysis revealed that the cutoff value of PG I was 123 ng/mL, with 80% sensitivity and 61.4% specificity. H. pylori infection combined with PG I at >123 ng/mL had an OR (95% CI) of 15.8 (2.4 ± 104.5) for the prediction of aspirin-induced gastroduodenal injury. Key Messages: Serum PG I and H. pylori infection could be used to identify potential high-risk aspirin-induced gastroduodenal injury patients. © 2017 S. Karger AG, Basel.

  6. Development of a highly sensitive lithium fluoride thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Moraes da Silva, Teresinha de; Campos, Leticia Lucente

    1995-01-01

    In recent times, LiF: Mg, Cu, P thermoluminescent phosphor has been increasingly in use for radiation monitoring due its high sensitivity and ease of preparation. The Dosimetric Materials Production Laboratory of IPEN, (Nuclear Energy Institute) has developed a simple method to obtain high sensitivity LiF. The preparation method is described. (author). 4 refs., 1 fig., 1 tab

  7. Triggers for a high sensitivity charm experiment

    International Nuclear Information System (INIS)

    Christian, D.C.

    1994-07-01

    Any future charm experiment clearly should implement an E T trigger and a μ trigger. In order to reach the 10 8 reconstructed charm level for hadronic final states, a high quality vertex trigger will almost certainly also be necessary. The best hope for the development of an offline quality vertex trigger lies in further development of the ideas of data-driven processing pioneered by the Nevis/U. Mass. group

  8. CROHN’S DISEASE DIAGNOSTICS IN ACUTE STAGE WITH THE USE OF HIGHLY EFFECTIVE LIQUID CHROMATOGRAPHY BLOOD SERUM

    Directory of Open Access Journals (Sweden)

    S.V. Krishtopenko

    2008-06-01

    Full Text Available 15 patients with the endoscopically and morphologically verified diagnosis of the Crohn’s disease and 14 healthy humans at the age of 23- 24 years have been examined. The Crohn’s disease index activity was 235 - 310 units. The possibility highly effective liquid chromatography blood serum use for diagnosis of the disease has been studied. A blood serum dried extract has been investigated on the "Milichrome A 02" chromatograph (Novosibirsk, "Econova "joint-stock company. The chromatograms have been treated with the use of a multilevel cluster analysis with a pathologic three-measured state form, differing from a healthy human. A diagnostic sensitivity and accuracy of the method has achieved 100%.

  9. Serum lipids, apoproteins and nutrient intake in rural Cretan boys consuming high-olive-oil diets.

    NARCIS (Netherlands)

    Aravanis, C.; Mensink, R.P.; Karalias, N.; Christodoulou, B.; Kafatos, A.; Katan, M.B.

    1988-01-01

    A high intake of olive oil has produced high levels of high-density and low levels of low-density lipoprotein cholesterol in short-term dietary trials. To investigate long-term effects of olive oil we have studied the diet and serum lipids of boys in Crete, where a high olive oil consumption is the

  10. A sensitive radio-immunoassay for serum thyroglobulin -including a correct screening for thyroglobulin autoantibodies

    International Nuclear Information System (INIS)

    Laurberg, Peter; Pedersen, K.M.

    1987-01-01

    A new thyroglobulin (Tg) assay employing polyethylene glycol (PEG) for separation of free and antibody bound : 125 I:Tg is described. By choosing a suitable PEG concentration the non-specific precipitation of free [ 125 I]Tg was kept low while both [ 125 I]Tg bound to rabbit anti-Tg immunoglobulins and to human Tg autoantibodies were precipitated. For all sera a 'blank' incubation with no rabbit anti-Tg immunoglobulins was run in parallel with the assay tubes. Hence any interference of Tg autoantibodies would be detected. A two-phase incubation gave a very low detection limit of 0.2 μg/l. The inter-assay coefficient of variation was 9.4% and the intra-assay coefficient of variation was 5.6%. Dilution curves of normal sera were parallel to the standard curve and Tg standards added to normal sera were recovered quantitatively. Twelve out of 60 normal sera from the Randers area contained Tg autoantibodies. The average serum Tg in the 48 sera without antibody was 44.6 ± 5.2 μg/l. (author)

  11. Segmentectomy for giant pulmonary sclerosing haemangiomas with high serum KL-6 levels

    Science.gov (United States)

    Kuroda, Hiroaki; Mun, Mingyon; Okumura, Sakae; Nakagawa, Ken

    2012-01-01

    We describe a 61-year old female patient with a giant pulmonary sclerosing haemangioma (PSH) and an extremely high preoperative serum KL-6 level. During an annual health screening, the patient showed a posterior mediastinal mass on chest radiography. Chest computed tomography and magnetic resonance imaging revealed a well-circumscribed 60 mm diameter nodule with a marked contrast enhancement in the left lower lobe. The preoperative serum KL-6 level was elevated to 8204 U/ml. We performed a four-port thoracoscopic basal segmentectomy and lymph node sampling for diagnosis and therapy. The postoperative diagnosis showed PSH. The serum KL-6 level decreased dramatically with tumour resection. To the best of our knowledge, this is the first report of a patient with PSH showing a high serum KL-6 level. PMID:22454483

  12. Low Power and High Sensitivity MOSFET-Based Pressure Sensor

    International Nuclear Information System (INIS)

    Zhang Zhao-Hua; Ren Tian-Ling; Zhang Yan-Hong; Han Rui-Rui; Liu Li-Tian

    2012-01-01

    Based on the metal-oxide-semiconductor field effect transistor (MOSFET) stress sensitive phenomenon, a low power MOSFET pressure sensor is proposed. Compared with the traditional piezoresistive pressure sensor, the present pressure sensor displays high performances on sensitivity and power consumption. The sensitivity of the MOSFET sensor is raised by 87%, meanwhile the power consumption is decreased by 20%. (cross-disciplinary physics and related areas of science and technology)

  13. High serum testosterone levels during postpartum period are associated with postpartum depression.

    Science.gov (United States)

    Aswathi, A; Rajendiren, Soundravally; Nimesh, Archana; Philip, R Ravi; Kattimani, Shivanand; Jayalakshmi, D; Ananthanarayanan, P H; Dhiman, Pooja

    2015-10-01

    In view of the reported cases of mood disorders that occur in mothers following childbirth and believing that sex steroid hormones contribute to mood and behavioral changes, this study has been aimed to explore the role of sex steroid hormones as an etiological factor for postpartum depression (PPD). This study was conducted at JIPMER, Puducherry, India between January 2010 and 2011. 103 women were recruited in the study after childbirth, out of which 62 women who were believed to be suffering from PPD were categorized as cases and the remaining 41 with no mood changes as controls, using Edinburgh Postpartum Depression Scale (EPDS) (cases had EPDS score ≥10 at 24-28h, controls had score postpartum). The hormones estimated in these two groups included estradiol, progesterone and testosterone, and their levels were compared between these two groups. A significantly high testosterone levels were observed in cases with PPD at 24-28h when compared to controls. Estradiol and progesterone levels did not show significant difference between cases and controls. ROC analysis done at 24-28h showed that testosterone levels beyond 42.71ng/mL predict the development of PPD with 79% sensitivity, 63% specificity, 68% positive predictive value, 74% negative predictive value with AUC being 0.708. This study shows that there is an association between persistent high serum testosterone level in women following childbirth and PPD. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Segmentectomy for giant pulmonary sclerosing haemangiomas with high serum KL-6 levels

    OpenAIRE

    Kuroda, Hiroaki; Mun, Mingyon; Okumura, Sakae; Nakagawa, Ken

    2012-01-01

    We describe a 61-year old female patient with a giant pulmonary sclerosing haemangioma (PSH) and an extremely high preoperative serum KL-6 level. During an annual health screening, the patient showed a posterior mediastinal mass on chest radiography. Chest computed tomography and magnetic resonance imaging revealed a well-circumscribed 60 mm diameter nodule with a marked contrast enhancement in the left lower lobe. The preoperative serum KL-6 level was elevated to 8204 U/ml. We performed a fo...

  15. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239

    OpenAIRE

    Powell, Rebecca L.R.; Ouellette, Ian; Lindsay, Ross W.; Parks, Christopher L.; King, C. Richter; McDermott, Adrian B.; Morrow, Gavin

    2013-01-01

    Abstract Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, w...

  16. New and highly sensitive assay for L-5-hydroxytryptophan decarboxylase activity by high-performance liquid chromatography-voltammetry.

    Science.gov (United States)

    Rahman, M K; Nagatsu, T; Kato, T

    1980-12-12

    This paper describes a new, inexpensive and highly sensitive assay for aromatic L-amino acid decarboxylase (AADC) activity, using L-5-hydroxytryptophan (L-5-HTP) as substrate, in rat and human brains and serum by high-performance liquid chromatography (HPLC) with voltammetric detection. L-5-HTP was used as substrate and D-5-HTP for the blank. After isolating serotonin (5-HT) formed enzymatically from L-5-HTP on a small Amberlite CG-50 column, the 5-HT was eluted with hydrochloric acid and assayed by HPLC with a voltammetric detector. N-Methyldopamine was added to each incubation mixture as an internal standard. This method is sensitive enough to measure 5-HT, formed by the enzyme, 100 fmol to 140 pmol or more. An advantage of this method is that one can incubate the enzyme for longer time (up to 150 min), as compared with AADC assay using L-DOPA as substrate, resulting in a very high sensitivity. By using this new method, AADC activity was discovered in rat serum.

  17. Elevated level of serum triglyceride among high risk stress bank ...

    African Journals Online (AJOL)

    The objective of this study was to estimate lipid profile among high risk stress bank employees' correlated with heart disorders in Riyadh, Saudi Arabia. A total of 129 patients with high risk stress employees were involved in this study, which were divided into 69 males and 60 females between the age of 25 to 55 years.

  18. Novel charge sensitive preamplifier without high-value feedback resistor

    International Nuclear Information System (INIS)

    Xi Deming

    1992-01-01

    A novel charge sensitive preamplifier is introduced. The method of removing the high value feedback resistor, the circuit design and analysis are described. A practical circuit and its measured performances are provided

  19. Effects of Shiitake Intake on Serum Lipids in Rats Fed Different High-Oil or High-Fat Diets.

    Science.gov (United States)

    Asada, Norihiko; Kairiku, Rumi; Tobo, Mika; Ono, Akifumi

    2018-04-27

    Shiitake (Lentinula edodes) extract, eritadenine, has been shown to reduce cholesterol levels, and its hypocholesterolemic actions are involved in the metabolism of methionine. However, the mechanisms by which eritadenine affects cholesterol metabolism in animals fed a high-fat diet containing different sources of lipids have not yet been elucidated in detail. This study was conducted to investigate the effects of shiitake supplementation on serum lipid concentrations in rats fed a diet including a high amount of a plant oil (HO [high oil] and HOS [high oil with shiitake] groups), animal fat (HF [high fat] and HFS [high fat with shiitake] groups), or MCT- (medium-chain triglyceride-) rich plant oil (HM [high MCT] and HMS [high MCT with shiitake] groups). Rats in the HOS, HFS, and HMS groups were fed shiitake. When rats were fed a diet containing shiitake, serum triglyceride, cholesterol levels, and LCAT (lecithin-cholesterol acyltransferase) activities were lower in rats given MCT-rich plant oil than in those that consumed lard. The lipid type in the diet with shiitake also affected serum cholesterol levels and LCAT activities. The diet containing MCT-rich plant oil showed the greatest rates of decrease in all serum lipid profiles and LCAT activities. These results suggest that shiitake and MCT-rich plant oil work together to reduce lipid profiles and LCAT activity in serum.

  20. Canine distemper virus neutralization activity is low in human serum and it is sensitive to an amino acid substitution in the hemagglutinin protein.

    Science.gov (United States)

    Zhang, Xinsheng; Wallace, Olivia L; Domi, Arban; Wright, Kevin J; Driscoll, Jonathan; Anzala, Omu; Sanders, Eduard J; Kamali, Anatoli; Karita, Etienne; Allen, Susan; Fast, Pat; Gilmour, Jill; Price, Matt A; Parks, Christopher L

    2015-08-01

    Serum was analyzed from 146 healthy adult volunteers in eastern Africa to evaluate measles virus (MV) and canine distemper virus (CDV) neutralizing antibody (nAb) prevalence and potency. MV plaque reduction neutralization test (PRNT) results indicated that all sera were positive for MV nAbs. Furthermore, the 50% neutralizing dose (ND50) for the majority of sera corresponded to antibody titers induced by MV vaccination. CDV nAbs titers were low and generally were detected in sera with high MV nAb titers. A mutant CDV was generated that was less sensitive to neutralization by human serum. The mutant virus genome had 10 nucleotide substitutions, which coded for single amino acid substitutions in the fusion (F) and hemagglutinin (H) glycoproteins and two substitutions in the large polymerase (L) protein. The H substitution occurred in a conserved region involved in receptor interactions among morbilliviruses, implying that this region is a target for cross-reactive neutralizing antibodies. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Serum leptin levels correlation with high blood pressure in adult females

    International Nuclear Information System (INIS)

    Haque, Z.; Shahid, K.U.; Mazahir, I.; Lakho, G.R.; Nafees, M.

    2006-01-01

    To measure serum leptin levels and compare them in lean and obese subjects and to identify correlation between serum leptin levels, heart rate and hypertension in lean and obese subjects among adult females. Seventy female subjects with different body mass indices were selected from OPD of Jinnah Medical and Dental College Hospital (OPD), Karachi. Heart rate was counted manually; blood pressure was measured by mercury sphygmomanometer while serum leptin was measured using enzyme-linked immunoassay. The outcomes hypertension and heart rate were correlated to risk factor leptin. Mean heart rate, systolic and diastolic blood pressure and serum leptin levels of obese people were 90+-1, 142+-2, 89+-1 and 24.13+-1.7 respectively, which were significantly higher as compared to lean subjects (p<0.05). All the parameters correlated positively and significantly with increasing BMI. There was a relationship of tachycardia and hypertension with high serum leptin levels in obesity. Serum leptin levels increase with the level of obesity. Hyper-leptinemia is associated with tachycardia and increases in both systolic and diastolic blood pressure in obesity via complex mechanisms. (author)

  2. Is serum zinc associated with pancreatic beta cell function and insulin sensitivity in pre-diabetic and normal individuals? Findings from the Hunter Community Study.

    Directory of Open Access Journals (Sweden)

    Khanrin P Vashum

    Full Text Available AIM: To determine if there is a difference in serum zinc concentration between normoglycaemic, pre-diabetic and type-2 diabetic groups and if this is associated with pancreatic beta cell function and insulin sensitivity in the former 2 groups. METHOD: Cross sectional study of a random sample of older community-dwelling men and women in Newcastle, New South Wales, Australia. Beta cell function, insulin sensitivity and insulin resistance were calculated for normoglycaemic and prediabetes participants using the Homeostasis Model Assessment (HOMA-2 calculator. RESULT: A total of 452 participants were recruited for this study. Approximately 33% (N = 149 had diabetes, 33% (N = 151 had prediabetes and 34% (N = 152 were normoglycaemic. Homeostasis Model Assessment (HOMA parameters were found to be significantly different between normoglycaemic and prediabetes groups (p<0.001. In adjusted linear regression, higher serum zinc concentration was associated with increased insulin sensitivity (p = 0.01 in the prediabetic group. There was also a significant association between smoking and worse insulin sensitivity. CONCLUSION: Higher serum zinc concentration is associated with increased insulin sensitivity. Longitudinal studies are required to determine if low serum zinc concentration plays a role in progression from pre-diabetes to diabetes.

  3. Effects of high grade bentonite on performance, organ weights and serum biochemistry during aflatoxicosis in broilers

    Directory of Open Access Journals (Sweden)

    H. C. Indresh

    2013-12-01

    Full Text Available Aim: To evaluate the effect of different levels of High Bentonite on growth performance, organ weight and serum biochemistry in broiler fed on diets containing aflatoxin. Materials and Methods: A total of 360 day-old commercial broiler chicks were divided at random into 8 dietary treatment groups of 42 chicks each having 3 replicates. Dietary levels of aflatoxin (0.5 ppm and High-grade bentonite (0.5, 0.75 and 1.00% were tested in a completely randomized design manner, forming a total of 8 dietary treatments each with three replicates. Body weight and feed intake were recorded weekly. At 5 wk, six birds from each treatment were sacrificed and liver, kidney, gizzard, pancreas, spleen, bursa of Fabricius and thymus were extracted and weighed. The serum samples were analyzed for total proteins, uric acid, serum albumin, serum globulin and the activities of gamma glutamyl transferase (GGT, alanine amino transferase (ALT and for antibody titers against Newcastle disease (ND and infectious bursal disease (IBD using ELISA technique. Results: A significant (P<0.05 decrease in body weight, feed consumption, relative weights of bursa, thymus, serum protein, anti body titers against NDV and IBDV, and increase in FCR, mortality, relative weight of liver, kidney, and the activity of Gamma Glutamyl Transferase (GGT was observed. However, the relative weights of gizzard, pancreas, spleen, serum albumin, uric acid and the activity of Alanine Amino Transferase (ALT were not influenced by inclusion of AF or HGB. Conclusion: The addition of HGB restored the harmful effects of AF on body weight, feed consumption, FCR, mortality, relative weight of liver, kidney, serum protein, IBDV and NDV. Supplementation of high grade bentonite at 1.0 per cent level was found to be beneficial in ameliorating the adverse effects of aflatoxin (AF in broiler chickens. [Vet World 2013; 6(6.000: 313-317

  4. IgA response in serum and gut secretion in sensitized mice fed with the dust mite Dermatophagoides pteronyssinus extract

    Directory of Open Access Journals (Sweden)

    Maciel M.

    2004-01-01

    Full Text Available Induced oral tolerance to mucosal-exposed antigens in immunized animals is of particular interest for the development of immunotherapeutic approaches to human allergic diseases. This is a unique feature of mucosal surfaces which represent the main contact interface with the external environment. However, the influence of oral tolerance on specific and natural polyreactive IgA antibodies, the major defense mechanism of the mucosa, is unknown. We have shown that oral administration of an extract of the dust mite Dermatophagoides pteronyssinus (Dp to primed mice caused down-regulation of IgE responses and an increase in tumor growth factor-ß secretion. In the present study, we observed that primed inbred female A/Sn mice (8 to 10 weeks old fed by gavage a total weight of 1.0-mg Dp extract on the 6th, 7th and 8th days post-immunization presented normal secretion of IL-4 and IL-10 in gut-associated lymphoid tissue and a decreased production of interferon gamma induced by Dp in the draining lymph nodes (13,340 ± 3,519 vs 29,280 ± 2,971 pg/ml. Mice fed the Dp extract also showed higher levels of serum anti-Dp IgA antibodies and an increase of IgA-secreting cells in mesenteric lymph nodes (N = 10, reflecting an increase in total fecal IgA antibodies (N = 10. The levels of secretory anti-Dp IgA antibodies increased after re-immunization regardless of Dp extract feeding. Oral tolerance did not interfere with serum or secretory IgA antibody reactivity related to self and non-self antigens. These results suggest that induction of oral tolerance to a Dp extract in sensitized mice triggered different regulatory mechanisms which inhibited the IgE response and stimulated systemic and secretory IgA responses, preserving the natural polyreactive IgA antibody production.

  5. A high-sensitivity neutron counter and waste-drum counting with the high-sensitivity neutron instrument

    International Nuclear Information System (INIS)

    Hankins, D.E.; Thorngate, J.H.

    1993-04-01

    At Lawrence Livermore National Laboratory (LLNL), a highly sensitive neutron counter was developed that can detect and accurately measure the neutrons from small quantities of plutonium or from other low-level neutron sources. This neutron counter was originally designed to survey waste containers leaving the Plutonium Facility. However, it has proven to be useful in other research applications requiring a high-sensitivity neutron instrument

  6. Sensitivity Comparison of the Skin Prick Test and Serum and Fecal Radio Allergosorbent Test (RAST in Diagnosis of Food Allergy in Children

    Directory of Open Access Journals (Sweden)

    Hamid Reza Kianifar

    2016-05-01

    Full Text Available Background: Diagnosis of food allergy is difficult in children. Food allergies are diagnosed using several methods that include medical histories, clinical examinations, skin prick and serum-specific immunoglobulin E (IgE tests, radio-allergosorbent test (RAST, food challenge, and supervised elimination diets. In this study we evaluated allergies to cow's milk, egg, peanut, and fish in children with suspected food allergies with skin prick tests and serum and feces RAST. Methods: Forty-one children with clinical symptoms of food allergies were enrolled in the study. Skin prick tests and serum and fecal RAST were performed and compared with challenge tests. Results: The most common sites of food allergy symptoms were gastrointestinal (82.9% and skin (48.8%. 100% of the patients responded to the challenge tests with cow’s milk, egg, peanut, and fish. 65% of the patients tested positive with the skin prick test, 12.1% tested positive with serum RAST, and 29.2% tested positive with fecal RAST. Conclusions: The skin prick test was more sensitive than serum or fecal RAST, and fecal RAST was more than twice as sensitive as serum RAST.

  7. Serum osteoprotegerin levels and mammographic density among high-risk women.

    Science.gov (United States)

    Moran, Olivia; Zaman, Tasnim; Eisen, Andrea; Demsky, Rochelle; Blackmore, Kristina; Knight, Julia A; Elser, Christine; Ginsburg, Ophira; Zbuk, Kevin; Yaffe, Martin; Narod, Steven A; Salmena, Leonardo; Kotsopoulos, Joanne

    2018-06-01

    Mammographic density is a risk factor for breast cancer but the mechanism behind this association is unclear. The receptor activator of nuclear factor κB (RANK)/RANK ligand (RANKL) pathway has been implicated in the development of breast cancer. Given the role of RANK signaling in mammary epithelial cell proliferation, we hypothesized this pathway may also be associated with mammographic density. Osteoprotegerin (OPG), a decoy receptor for RANKL, is known to inhibit RANK signaling. Thus, it is of interest to evaluate whether OPG levels modify breast cancer risk through mammographic density. We quantified serum OPG levels in 57 premenopausal and 43 postmenopausal women using an enzyme-linked immunosorbent assay (ELISA). Cumulus was used to measure percent density, dense area, and non-dense area for each mammographic image. Subjects were classified into high versus low OPG levels based on the median serum OPG level in the entire cohort (115.1 pg/mL). Multivariate models were used to assess the relationship between serum OPG levels and the measures of mammographic density. Serum OPG levels were not associated with mammographic density among premenopausal women (P ≥ 0.42). Among postmenopausal women, those with low serum OPG levels had higher mean percent mammographic density (20.9% vs. 13.7%; P = 0.04) and mean dense area (23.4 cm 2 vs. 15.2 cm 2 ; P = 0.02) compared to those with high serum OPG levels after covariate adjustment. These findings suggest that low OPG levels may be associated with high mammographic density, particularly in postmenopausal women. Targeting RANK signaling may represent a plausible, non-surgical prevention option for high-risk women with high mammographic density, especially those with low circulating OPG levels.

  8. Highly sensitive and selective cholesterol biosensor based on direct electron transfer of hemoglobin.

    Science.gov (United States)

    Zhao, Changzhi; Wan, Li; Jiang, Li; Wang, Qin; Jiao, Kui

    2008-12-01

    A cholesterol biosensor based on direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode has been developed for highly sensitive and selective analysis of serum samples. Modified by films containing hemoglobin and cholesterol oxidase, the electrode was prepared by encapsulation of enzyme in chitosan matrix. The hydrogen peroxide produced by the catalytic oxidation of cholesterol by cholesterol oxidase was reduced electrocatalytically by immobilized hemoglobin and used to obtain a sensitive amperometric response to cholesterol. The linear response of cholesterol concentrations ranged from 1.00 x 10(-5) to 6.00 x 10(-4) mol/L, with a correlation coefficient of 0.9969 and estimated detection limit of cholesterol of 9.5 micromol/L at a signal/noise ratio of 3. The cholesterol biosensor can efficiently exclude interference by the commonly coexisting ascorbic acid, uric acid, dopamine, and epinephrine. The sensitivity to the change in the concentration of cholesterol as the slope of the calibration curve was 0.596 A/M. The relative standard deviation was under 4.0% (n=5) for the determination of real samples. The biosensor is satisfactory in the determination of human serum samples.

  9. Sensitive assays enable detection of serum IgG antibodies against Clostridium difficile toxin A and toxin B in healthy subjects and patients with Clostridium difficile infection.

    Science.gov (United States)

    Zhao, Xuemei; Bender, Florent; Shukla, Rajiv; Kang, John J; Caro-Aguilar, Ivette; Laterza, Omar F

    2016-04-01

    Pathogenic Clostridium difficile produces two proinflammatory exotoxins, toxin A and toxin B. Low level of serum antitoxin IgG antibodies is a risk factor for the development of primary and recurrent C. difficile infection (CDI). We developed and validated two sensitive, titer-based electrochemiluminescence assays for the detection of serum antibody levels against C. difficile toxins A and B. These assays demonstrated excellent precision. The sensitivity of the assays allowed the detection of antitoxin A and antitoxin B IgG antibodies in all tested serum samples during assay validation. The validated titer-based assays enable assessment of antitoxin A and antitoxin B IgG antibodies as potential biomarkers to identify patients with CDI at increased risk for CDI recurrence.

  10. The relationship between serum adiponectin and postpartum luteal activity in high-producing dairy cows.

    Science.gov (United States)

    Kafi, Mojtaba; Tamadon, Amin; Saeb, Mehdi

    2015-05-01

    The aims of the present study were to initially determine the pattern of serum adiponectin concentrations during a normal estrous cycle in high-producing postpartum dairy cows and then evaluate the relationship between the serum concentrations of adiponectin and insulin with the commencement of postpartum luteal activity and ovarian activities in clinically healthy high-producing Holstein dairy cows. During a normal estrous cycle of cows (n = 6), serum adiponectin concentrations gradually decreased (P Cows with higher peak of milk yield had lower serum adiponectin concentrations by week 7 postpartum (P = 0.01). Serum adiponectin and insulin concentrations in cows with different postpartum luteal activity (based on the progesterone profile) were evaluated using the following class of cows: normal (≤45 days, n = 11) and delayed (>45 days, n = 11) commencement of luteal activity (C-LA) and four different profiles of normal luteal activity (NLA, n = 5), prolonged luteal phase (n = 6), delayed first ovulation (n = 6), and anovulation (AOV, n = 5). Serum adiponectin concentrations decreased gradually by week 3 postpartum in NLA and then increased; whereas in AOV and delayed first ovulation, they were decreased after week 3 postpartum (P cows was more than that of NLA cows. Insulin concentrations were almost maintained at a stable level in NLA cows (P > 0.05), whereas they increased in the other groups (P cows with C-LA greater than 45 days decreased more than those with C-LA 45 days or less after week 3 postpartum (P = 0.002). Serum adiponectin concentrations at week 7 postpartum were lower in delayed C-LA (P = 0.01). Milk yield in cows with C-LA greater than 45 days increased more than cows with C-LA 45 days or less postpartum (P = 0.002). Insulin concentrations increased relatively in parallel from weeks 1 to 7 postpartum in cows either with C-LA greater than 45 or with C-LA 45 days or less. We showed for the first time the profile of serum adiponectin concentrations

  11. Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xuejiang; Tang, Keqi

    2017-06-14

    Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode

  12. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  13. Synthesis and characterization of dipicolinate sensitized LaF3:Tb3+ nanoparticles and their interaction with bovine serum albumin

    International Nuclear Information System (INIS)

    Jing, Kui; Guo, Xingjia; Diao, Xin; Wu, Qiong; Jiang, Yuchun; Sun, Ye; Pan, Xintong; Zhou, Nannan; Zhu, Yanjun

    2015-01-01

    Dipicolinate sensitized LaF 3 :Tb 3+ luminescent nanoparticles (DPA-NPs) have been successfully synthesized and characterized for their morphology, structural and optical properties. It was found that the prepared DPA-NPs were spherical with an average diameter of 10 nm and their surfaces were capped by citric acid radicals and DPA. And then the interaction between DPA-NPs and bovine serum albumin (BSA) was investigated by fluorescence quenching, UV–visible absorption, circular dichroism (CD) and Fourier transform infrared (FT-IR) spectroscopy under the simulative physiological conditions. The results showed that DPA-NPs had a strong ability to quench the intrinsic fluorescence of BSA by forming 1:1 ground-state complexes with a binding constant of about 10 4 L mol −1 . Moreover, the values of the calculated thermodynamic parameters suggested that hydrophobic forces and hydrogen bonds played major roles in stabilizing the complex. The displacement experiments indicated that the binding of DPA-NPs primarily occurred in sub-domain II A (site I) of BSA. The binding distance r was calculated to be 1.9 nm based on the theory of Förster's non-radiation energy transfer. Finally, the analysis of synchronous fluorescence, FT-IR, CD, and three-dimensional fluorescence spectra revealed that the microenvironment of amino acid residues and the conformation of BSA were changed after the addition of DPA-NPs. - Highlights: • Dipicolinate sensitized LaF 3 :Tb 3+ luminescent nanoparticles (DPA-NPs) were synthesized by the hydrothermal method. • DPA-NPs have a strong ability to quench the intrinsic fluorescence of BSA by forming a 1:1 ground state complex. • Hydrophobic force and hydrogen bond played major roles in the binding of DPA-NPs to BSA. • The microenvironment of amino acid residues and the conformation of BSA were changed upon addition of DPA-NPs

  14. Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases

    International Nuclear Information System (INIS)

    Choo, In Wook; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan

    1986-01-01

    The aim of percutaneous transhepatic biliary drainage (PTBD) is to decrease serum bilirubin level and promote liver function in patient with biliary tract disease, especially obstruction by malignant disease. But some patients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepatic biliary drainage was performed in 341 patients of obstructive jaundice for 5 years form July, 1981 to July, 1986 at department of radiology, Seoul National University Hospital. Follow up check of the serum bilirubin level was possible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubin level after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant disease were 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of metastasis from stomach, colon and uterine cervix. Benign disease were 1 case of common hepatic duct stone and 1 case of intrahepatic duct stones. 3. The most common level of obstruction was trifurcation in 17 cases. 4. The most common indication of PTBD was palliative drainage of obstruction secondary to malignant tumor in 28 cases. 5. Change of serum bilirubin level ratio (post-PTBD level/pre-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1-3 days, 4-6 days, 1-2 week 2-3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partial drainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases of biliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of catheter including 4 cases of hemobilia, 1 case of multiple intrahepatic stones, pyobilia and intrahepatic Clonorchis sinensis.

  15. Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-12-15

    The aim of percutaneous transhepatic biliary drainage (PTBD) is to decrease serum bilirubin level and promote liver function in patient with biliary tract disease, especially obstruction by malignant disease. But some patients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepatic biliary drainage was performed in 341 patients of obstructive jaundice for 5 years form July, 1981 to July, 1986 at department of radiology, Seoul National University Hospital. Follow up check of the serum bilirubin level was possible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubin level after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant disease were 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of metastasis from stomach, colon and uterine cervix. Benign disease were 1 case of common hepatic duct stone and 1 case of intrahepatic duct stones. 3. The most common level of obstruction was trifurcation in 17 cases. 4. The most common indication of PTBD was palliative drainage of obstruction secondary to malignant tumor in 28 cases. 5. Change of serum bilirubin level ratio (post-PTBD level/pre-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1-3 days, 4-6 days, 1-2 week 2-3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partial drainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases of biliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of catheter including 4 cases of hemobilia, 1 case of multiple intrahepatic stones, pyobilia and intrahepatic Clonorchis sinensis.

  16. A large, benign prostatic cyst presented with an extremely high serum prostate-specific antigen level.

    Science.gov (United States)

    Chen, Han-Kuang; Pemberton, Richard

    2016-01-08

    We report a case of a patient who presented with an extremely high serum prostate specific antigen (PSA) level and underwent radical prostatectomy for presumed prostate cancer. Surprisingly, the whole mount prostatectomy specimen showed only small volume, organ-confined prostate adenocarcinoma and a large, benign intraprostatic cyst, which was thought to be responsible for the PSA elevation. 2016 BMJ Publishing Group Ltd.

  17. High-pressure liquid chromatographic assay of Bay n 7133 in human serum.

    OpenAIRE

    Fasching, C E; Hughes, C E; Hector, R F; Peterson, L R

    1984-01-01

    A high-pressure liquid chromatographic method that includes a Sep-Pak (Waters Associates, Inc., Milford , Mass.) preparation of human serum was employed for the quantitative assay of Bay n 7133. Drug levels of 0.1 to 20 micrograms/ml could be detected. No interference from amphotericin B was found in the chromatographic analysis of Bay n 7133.

  18. High serum ACE activity predicts severe hypoglycaemia over time in patients with type 1 diabetes

    DEFF Research Database (Denmark)

    Færch, Louise; Pedersen-Bjergaard, Ulrik; Thorsteinsson, Birger

    2011-01-01

    High serum angiotensin-converting enzyme (ACE) activity is associated with increased risk of severe hypoglycaemia (SH) within 1 year in type 1 diabetes. We wanted to find out whether ACE activity is stable over time and predicts SH beyond 1 year, and if gender differences exist in the association...

  19. Retinal sensitivity and choroidal thickness in high myopia.

    Science.gov (United States)

    Zaben, Ahmad; Zapata, Miguel Á; Garcia-Arumi, Jose

    2015-03-01

    To estimate the association between choroidal thickness in the macular area and retinal sensitivity in eyes with high myopia. This investigation was a transversal study of patients with high myopia, all of whom had their retinal sensitivity measured with macular integrity assessment microperimetry. The choroidal thicknesses in the macular area were then measured by optical coherence tomography, and statistical correlations between their functionality and the anatomical structuralism, as assessed by both types of measurements, were analyzed. Ninety-six eyes from 77 patients with high myopia were studied. The patients had a mean age ± standard deviation of 38.9 ± 13.2 years, with spherical equivalent values ranging from -6.00 diopter to -20.00 diopter (8.74 ± 2.73 diopter). The mean central choroidal thickness was 159.00 ± 50.57. The mean choroidal thickness was directly correlated with sensitivity (r = 0.306; P = 0.004) and visual acuity but indirectly correlated with the spherical equivalent values and patient age. The mean sensitivity was not significantly correlated with the macular foveal thickness (r = -0.174; P = 0.101) or with the overall macular thickness (r = 0.103; P = 0.334); furthermore, the mean sensitivity was significantly correlated with visual acuity (r = 0.431; P < 0.001) and the spherical equivalent values (r = -0.306; P = 0.003). Retinal sensitivity in highly myopic eyes is directly correlated with choroidal thickness and does not seem to be associated with retinal thickness. Thus, in patients with high myopia, accurate measurements of choroidal thickness may provide more accurate information about this pathologic condition because choroidal thickness correlates to a greater degree with the functional parameters, patient age, and spherical equivalent values.

  20. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    DEFF Research Database (Denmark)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter

    2017-01-01

    of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared...... to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research highsensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time...

  1. BH3105 type neutron dose equivalent meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Enshan; Yang Jianfeng; Zhang Hong; Huang Jiling

    1995-10-01

    It is noted that to design a neutron dose meter of high sensitivity is almost impossible in the frame of traditional designing principle--'absorption net principle'. Based on a newly proposed principle of obtaining neutron dose equi-biological effect adjustment--' absorption stick principle', a brand-new neutron dose-equivalent meter with high neutron sensitivity BH3105 has been developed. Its sensitivity reaches 10 cps/(μSv·h -1 ), which is 18∼40 times higher than one of foreign products of the same kind and is 10 4 times higher than that of domestic FJ342 neutron rem-meter. BH3105 has a measurement range from 0.1μSv/h to 1 Sv/h which is 1 or 2 orders wider than that of the other's. It has the advanced properties of gamma-resistance, energy response, orientation, etc. (6 tabs., 5 figs.)

  2. A high sensitivity nanomaterial based SAW humidity sensor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, T-T; Chou, T-H [Institute of Applied Mechanics, National Taiwan University, Taipei 106, Taiwan (China); Chen, Y-Y [Department of Mechanical Engineering, Tatung University, Taipei 104, Taiwan (China)], E-mail: wutt@ndt.iam.ntu.edu.tw

    2008-04-21

    In this paper, a highly sensitive humidity sensor is reported. The humidity sensor is configured by a 128{sup 0}YX-LiNbO{sub 3} based surface acoustic wave (SAW) resonator whose operating frequency is at 145 MHz. A dual delay line configuration is realized to eliminate external temperature fluctuations. Moreover, for nanostructured materials possessing high surface-to-volume ratio, large penetration depth and fast charge diffusion rate, camphor sulfonic acid doped polyaniline (PANI) nanofibres are synthesized by the interfacial polymerization method and further deposited on the SAW resonator as selective coating to enhance sensitivity. The humidity sensor is used to measure various relative humidities in the range 5-90% at room temperature. Results show that the PANI nanofibre based SAW humidity sensor exhibits excellent sensitivity and short-term repeatability.

  3. Performance of terahertz metamaterials as high-sensitivity sensor

    Science.gov (United States)

    He, Yanan; Zhang, Bo; Shen, Jingling

    2017-09-01

    A high-sensitivity sensor based on the resonant transmission characteristics of terahertz (THz) metamaterials was investigated, with the proposal and fabrication of rectangular bar arrays of THz metamaterials exhibiting a period of 180 μm on a 25 μm thick flexible polyimide. Varying the size of the metamaterial structure revealed that the length of the rectangular unit modulated the resonant frequency, which was verified by both experiment and simulation. The sensing characteristics upon varying the surrounding media in the sample were tested by simulation and experiment. Changing the surrounding medium from that of air to that of alcohol or oil produced resonant frequency redshifts of 80 GHz or 150 GHz, respectively, which indicates that the sensor possessed a high sensitivity of 667 GHz per unit of refractive index. Finally, the influence of the sample substrate thickness on the sensor sensitivity was investigated by simulation. It may be a reference for future sensor design.

  4. Evaluation of the highly sensitive chemiluminescent enzyme immunoassay "Lumipulse HBsAg-HQ" for hepatitis B virus screening.

    Science.gov (United States)

    Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Tsukamoto, Hiroko; Takao, Miyuki; Tahara, Kazuko; Maeda, Ikuhiro; Hidaka, Yoh; Yamauchi, Satoshi; Kaneko, Atsushi; Miyakoshi, Hideo; Isomura, Mitsuo

    2017-10-06

    Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients. © 2017 Wiley Periodicals, Inc.

  5. Highly sensitive dendrimer-based nanoplasmonic biosensor for drug allergy diagnosis.

    Science.gov (United States)

    Soler, Maria; Mesa-Antunez, Pablo; Estevez, M-Carmen; Ruiz-Sanchez, Antonio Jesus; Otte, Marinus A; Sepulveda, Borja; Collado, Daniel; Mayorga, Cristobalina; Torres, Maria Jose; Perez-Inestrosa, Ezequiel; Lechuga, Laura M

    2015-04-15

    A label-free biosensing strategy for amoxicillin (AX) allergy diagnosis based on the combination of novel dendrimer-based conjugates and a recently developed nanoplasmonic sensor technology is reported. Gold nanodisks were functionalized with a custom-designed thiol-ending-polyamido-based dendron (d-BAPAD) peripherally decorated with amoxicilloyl (AXO) groups (d-BAPAD-AXO) in order to detect specific IgE generated in patient's serum against this antibiotic during an allergy outbreak. This innovative strategy, which follows a simple one-step immobilization procedure, shows exceptional results in terms of sensitivity and robustness, leading to a highly-reproducible and long-term stable surface which allows achieving extremely low limits of detection. Moreover, the viability of this biosensor approach to analyze human biological samples has been demonstrated by directly analyzing and quantifying specific anti-AX antibodies in patient's serum without any sample pretreatment. An excellent limit of detection (LoD) of 0.6ng/mL (i.e. 0.25kU/L) has been achieved in the evaluation of clinical samples evidencing the potential of our nanoplasmonic biosensor as an advanced diagnostic tool to quickly identify allergic patients. The results have been compared and validated with a conventional clinical immunofluorescence assay (ImmunoCAP test), confirming an excellent correlation between both techniques. The combination of a novel compact nanoplasmonic platform and a dendrimer-based strategy provides a highly sensitive label free biosensor approach with over two times better detectability than conventional SPR. Both the biosensor device and the carrier structure hold great potential in clinical diagnosis for biomarker analysis in whole serum samples and other human biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  7. Methylation-Sensitive High Resolution Melting (MS-HRM).

    Science.gov (United States)

    Hussmann, Dianna; Hansen, Lise Lotte

    2018-01-01

    Methylation-Sensitive High Resolution Melting (MS-HRM) is an in-tube, PCR-based method to detect methylation levels at specific loci of interest. A unique primer design facilitates a high sensitivity of the assays enabling detection of down to 0.1-1% methylated alleles in an unmethylated background.Primers for MS-HRM assays are designed to be complementary to the methylated allele, and a specific annealing temperature enables these primers to anneal both to the methylated and the unmethylated alleles thereby increasing the sensitivity of the assays. Bisulfite treatment of the DNA prior to performing MS-HRM ensures a different base composition between methylated and unmethylated DNA, which is used to separate the resulting amplicons by high resolution melting.The high sensitivity of MS-HRM has proven useful for detecting cancer biomarkers in a noninvasive manner in urine from bladder cancer patients, in stool from colorectal cancer patients, and in buccal mucosa from breast cancer patients. MS-HRM is a fast method to diagnose imprinted diseases and to clinically validate results from whole-epigenome studies. The ability to detect few copies of methylated DNA makes MS-HRM a key player in the quest for establishing links between environmental exposure, epigenetic changes, and disease.

  8. Aluminum nano-cantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nano-cantilevers using a very simple one mask contact UV lithography technique with lateral dimensions under 500 nm and vertical dimensions of approximately 100 nm. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Further...

  9. High sensitivity probe absorption technique for time-of-flight ...

    Indian Academy of Sciences (India)

    Abstract. We report on a phase-sensitive probe absorption technique with high sen- sitivity, capable of detecting a few hundred ultra-cold atoms in flight in an observation time of a few milliseconds. The large signal-to-noise ratio achieved is sufficient for reliable measurements on low intensity beams of cold atoms.

  10. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  11. Highly sensitive detection using microring resonator and nanopores

    Science.gov (United States)

    Bougot-Robin, K.; Hoste, J. W.; Le Thomas, N.; Bienstman, P.; Edel, J. B.

    2016-04-01

    One of the most significant challenges facing physical and biological scientists is the accurate detection and identification of single molecules in free-solution environments. The ability to perform such sensitive and selective measurements opens new avenues for a large number of applications in biological, medical and chemical analysis, where small sample volumes and low analyte concentrations are the norm. Access to information at the single or few molecules scale is rendered possible by a fine combination of recent advances in technologies. We propose a novel detection method that combines highly sensitive label-free resonant sensing obtained with high-Q microcavities and position control in nanoscale pores (nanopores). In addition to be label-free and highly sensitive, our technique is immobilization free and does not rely on surface biochemistry to bind probes on a chip. This is a significant advantage, both in term of biology uncertainties and fewer biological preparation steps. Through combination of high-Q photonic structures with translocation through nanopore at the end of a pipette, or through a solid-state membrane, we believe significant advances can be achieved in the field of biosensing. Silicon microrings are highly advantageous in term of sensitivity, multiplexing, and microfabrication and are chosen for this study. In term of nanopores, we both consider nanopore at the end of a nanopipette, with the pore being approach from the pipette with nanoprecise mechanical control. Alternatively, solid state nanopores can be fabricated through a membrane, supporting the ring. Both configuration are discussed in this paper, in term of implementation and sensitivity.

  12. NK sensitivity of neuroblastoma cells determined by a highly sensitive coupled luminescent method

    International Nuclear Information System (INIS)

    Ogbomo, Henry; Hahn, Anke; Geiler, Janina; Michaelis, Martin; Doerr, Hans Wilhelm; Cinatl, Jindrich

    2006-01-01

    The measurement of natural killer (NK) cells toxicity against tumor or virus-infected cells especially in cases with small blood samples requires highly sensitive methods. Here, a coupled luminescent method (CLM) based on glyceraldehyde-3-phosphate dehydrogenase release from injured target cells was used to evaluate the cytotoxicity of interleukin-2 activated NK cells against neuroblastoma cell lines. In contrast to most other methods, CLM does not require the pretreatment of target cells with labeling substances which could be toxic or radioactive. The effective killing of tumor cells was achieved by low effector/target ratios ranging from 0.5:1 to 4:1. CLM provides highly sensitive, safe, and fast procedure for measurement of NK cell activity with small blood samples such as those obtained from pediatric patients

  13. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10 -12 g and has an abundance sensitivity in excess of 10 6 . Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given

  14. A highly sensitive and specific assay for vertebrate collagenase

    International Nuclear Information System (INIS)

    Sodek, J.; Hurum, S.; Feng, J.

    1981-01-01

    A highly sensitive and specific assay for vertebrate collagenase has been developed using a [ 14 C]-labeled collagen substrate and a combination of SDS-PAGE (sodium dodecyl sulfate-polyacrylamide gel electrophoresis) and fluorography to identify and quantitate the digestion products. The assay was sufficiently sensitive to permit the detection and quantitation of collagenase activity in 0.1 μl of gingival sulcal fluid, and in samples of cell culture medium without prior concentration. The assay has also been used to detect the presence of inhibitors of collagenolytic enzymes in various cell culture fluids. (author)

  15. HighSensitivity C - reactive protein is associated with Traditional Cardiovascular Risk Factors in Indians with Type 2 Diabetes Mellitus

    OpenAIRE

    Asegaonkar, Shilpa B; Bavikar, Jayashree Suhas; Marathe, Amruta; Tekade, Mangesh; Asegaonkar, Balaji N.; Jayashree, Bardapurkar

    2013-01-01

    Background: India is experiencing twin epidemic of type 2 diabetes mellitus and cardiovascular diseases imposing huge toll on healthcare system. In type 2 diabetes 65-80% deaths occur due to cardiovascular disease whose etiology cannot be explained by chronic hyperglycemia, dyslipedemia and traditional cardiac risk factors. To improve risk stratification serum high-sensitivity C- reactive protein estimation is an adjunct to other risk factors. Study design: O.P.D. based Cross sectional study....

  16. High-protein diets in hyperlipidemia : effect of wheat gluten on serum lipids, uric acid, and renal function

    NARCIS (Netherlands)

    Jenkins, D.J.A.; Kendall, C.W.C.; Vidgen, E.; Augustin, L.S.A.; Erk, van M.; Geelen, A.; Parker, T.; Faulkner, D.; Vuksan, V.; Josse, R.G.; Leiter, L.A.; Connelly, P.W.

    2001-01-01

    BACKGROUND: The metabolic effects of diets high in vegetable protein have not been assessed despite much recent interest in the effect of soy proteins in reducing serum cholesterol. OBJECTIVE: We assessed the metabolic effects of diets high in vegetable protein (specifically, wheat gluten) on serum

  17. Are inflationary predictions sensitive to very high energy physics?

    International Nuclear Information System (INIS)

    Burgess, C.P.; Lemieux, F.; Holman, R.; Cline, J.M.

    2003-01-01

    It has been proposed that the successful inflationary description of density perturbations on cosmological scales is sensitive to the details of physics at extremely high (trans-Planckian) energies. We test this proposal by examining how inflationary predictions depend on higher-energy scales within a simple model where the higher-energy physics is well understood. We find the best of all possible worlds: inflationary predictions are robust against the vast majority of high-energy effects, but can be sensitive to some effects in certain circumstances, in a way which does not violate ordinary notions of decoupling. This implies both that the comparison of inflationary predictions with CMB data is meaningful, and that it is also worth searching for small deviations from the standard results in the hopes of learning about very high energies. (author)

  18. Design of highly sensitive multichannel bimetallic photonic crystal fiber biosensor

    Science.gov (United States)

    Hameed, Mohamed Farhat O.; Alrayk, Yassmin K. A.; Shaalan, Abdelhamid A.; El Deeb, Walid S.; Obayya, Salah S. A.

    2016-10-01

    A design of a highly sensitive multichannel biosensor based on photonic crystal fiber is proposed and analyzed. The suggested design has a silver layer as a plasmonic material coated by a gold layer to protect silver oxidation. The reported sensor is based on detection using the quasi transverse electric (TE) and quasi transverse magnetic (TM) modes, which offers the possibility of multichannel/multianalyte sensing. The numerical results are obtained using a finite element method with perfect matched layer boundary conditions. The sensor geometrical parameters are optimized to achieve high sensitivity for the two polarized modes. High-refractive index sensitivity of about 4750 nm/RIU (refractive index unit) and 4300 nm/RIU with corresponding resolutions of 2.1×10-5 RIU, and 2.33×10-5 RIU can be obtained according to the quasi TM and quasi TE modes of the proposed sensor, respectively. Further, the reported design can be used as a self-calibration biosensor within an unknown analyte refractive index ranging from 1.33 to 1.35 with high linearity and high accuracy. Moreover, the suggested biosensor has advantages in terms of compactness and better integration of microfluidics setup, waveguide, and metallic layers into a single structure.

  19. Association of high post-transplant soluble CD30 serum levels with chronic allograft nephropathy.

    Science.gov (United States)

    Grenzi, Patricia C; Campos, Érika F; Tedesco-Silva, Hélio; Felipe, Claudia R; Franco, Marcello F; Soares, Maria Fernanda; Medina-Pestana, José Osmar; Gerbase-Delima, Maria

    2013-12-01

    The purpose of this study was to evaluate the association of post-transplant soluble CD30 (sCD30) levels, isolated or in combination with of anti-HLA class II antibodies and of serum creatinine levels, with kidney graft loss due to chronic allograft nephropathy (CAN), and type of lesions in graft biopsies for cause. The study comprised 511 first kidney graft recipients, transplanted at a single center, with a graft functioning for at least 2.8 years. A single blood sample was collected from each patient. sCD30 levels were determined by ELISA, and HLA antibodies by Luminex assay. The minimum follow-up after testing was 9.3 years. High sCD30 levels, set at sCD30 ≥ 34.15 ng/mL, the presence of HLA class II antibodies, and serum creatinine ≥ 1.9 mg/dL were independently associated with CAN-graft loss (P values sCD30 levels and creatinine were independently associated with interstitial lesions. Post-transplant sCD30 serum levels, especially in conjunction with information regarding HLA class II antibodies and serum creatinine levels, provide valuable information regarding graft outcome and could be useful for the management of kidney transplant recipients. © 2013.

  20. High serum total cholesterol is a long-term cause of osteoporotic fracture.

    Science.gov (United States)

    Trimpou, P; Odén, A; Simonsson, T; Wilhelmsen, L; Landin-Wilhelmsen, K

    2011-05-01

    Risk factors for osteoporotic fractures were evaluated in 1,396 men and women for a period of 20 years. Serum total cholesterol was found to be an independent osteoporotic fracture risk factor whose predictive power improves with time. The purpose of this study was to evaluate long-term risk factors for osteoporotic fracture. A population random sample of men and women aged 25-64 years (the Gothenburg WHO MONICA project, N = 1,396, 53% women) was studied prospectively. The 1985 baseline examination recorded physical activity at work and during leisure time, psychological stress, smoking habits, coffee consumption, BMI, waist/hip ratio, blood pressure, total, HDL and LDL cholesterol, triglycerides, and fibrinogen. Osteoporotic fractures over a period of 20 years were retrieved from the Gothenburg hospital registers. Poisson regression was used to analyze the predictive power for osteoporotic fracture of each risk factor. A total number of 258 osteoporotic fractures occurred in 143 participants (10.2%). As expected, we found that previous fracture, smoking, coffee consumption, and lower BMI each increase the risk for osteoporotic fracture independently of age and sex. More unexpectedly, we found that the gradient of risk of serum total cholesterol to predict osteoporotic fracture significantly increases over time (p = 0.0377). Serum total cholesterol is an independent osteoporotic fracture risk factor whose predictive power improves with time. High serum total cholesterol is a long-term cause of osteoporotic fracture.

  1. A highly sensitive method for quantification of iohexol

    DEFF Research Database (Denmark)

    Schulz, A.; Boeringer, F.; Swifka, J.

    2014-01-01

    -chromatography-electrospray-massspectrometry (LC-ESI-MS) approach using the multiple reaction monitoring mode for iohexol quantification. In order to test whether a significantly decreased amount of iohexol is sufficient for reliable quantification, a LC-ESI-MS approach was assessed. We analyzed the kinetics of iohexol in rats after application...... of different amounts of iohexol (15 mg to 150 1.tg per rat). Blood sampling was conducted at four time points, at 15, 30, 60, and 90 min, after iohexol injection. The analyte (iohexol) and the internal standard (iotha(amic acid) were separated from serum proteins using a centrifugal filtration device...... with a cut-off of 3 kDa. The chromatographic separation was achieved on an analytical Zorbax SB C18 column. The detection and quantification were performed on a high capacity trap mass spectrometer using positive ion ESI in the multiple reaction monitoring (MRM) mode. Furthermore, using real-time polymerase...

  2. Hybridization chain reaction amplification for highly sensitive fluorescence detection of DNA with dextran coated microarrays.

    Science.gov (United States)

    Chao, Jie; Li, Zhenhua; Li, Jing; Peng, Hongzhen; Su, Shao; Li, Qian; Zhu, Changfeng; Zuo, Xiaolei; Song, Shiping; Wang, Lianhui; Wang, Lihua

    2016-07-15

    Microarrays of biomolecules hold great promise in the fields of genomics, proteomics, and clinical assays on account of their remarkably parallel and high-throughput assay capability. However, the fluorescence detection used in most conventional DNA microarrays is still limited by sensitivity. In this study, we have demonstrated a novel universal and highly sensitive platform for fluorescent detection of sequence specific DNA at the femtomolar level by combining dextran-coated microarrays with hybridization chain reaction (HCR) signal amplification. Three-dimensional dextran matrix was covalently coated on glass surface as the scaffold to immobilize DNA recognition probes to increase the surface binding capacity and accessibility. DNA nanowire tentacles were formed on the matrix surface for efficient signal amplification by capturing multiple fluorescent molecules in a highly ordered way. By quantifying microscopic fluorescent signals, the synergetic effects of dextran and HCR greatly improved sensitivity of DNA microarrays, with a detection limit of 10fM (1×10(5) molecules). This detection assay could recognize one-base mismatch with fluorescence signals dropped down to ~20%. This cost-effective microarray platform also worked well with samples in serum and thus shows great potential for clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  4. High serum soluble CD30 does not predict acute rejection in liver transplant patients.

    Science.gov (United States)

    Matinlauri, I; Höckerstedt, K; Isoniemi, H

    2006-12-01

    Increased pre- and posttransplantation values of soluble CD30 (sCD30) have been shown to be associated with acute kidney transplant rejection. We sought to study whether high sCD30 could predict rejection early after liver transplantation. The study population included 54 consecutive liver transplant patients, whose samples were collected before liver transplantation and at discharge, which was at a mean time of 3 weeks after transplantation. During the first 6 months posttransplantation, 22 patients experienced an acute rejection episode. Serum sCD30 concentrations were measured by an enzyme-linked immunoassay; changes in serum sCD30 levels posttransplantation were also expressed as relative values compared with pretransplantation results. Liver patients before transplantation displayed higher serum sCD30 values compared with healthy controls: mean values +/- SD were 93 +/- 58 IU/mL vs 17 +/- 8 IU/mL, respectively. At 3 weeks after transplantation the mean sCD30 concentration in liver transplant patients decreased to 59 +/- 42 IU/mL (P = .005). The mean pretransplantation serum sCD30 value was slightly lower among rejecting vs nonrejecting patients: 78 +/- 43 IU/mL vs 104 +/- 65 IU/mL (P = NS). Posttransplantation values in both groups decreased significantly: 47 +/- 34 IU/mL in patients with rejection (P = .014) vs 69 +/- 45 IU/mL in patients without rejection (P = .012). The relative value at 3 weeks posttransplantation decreased slightly more among patients with vs without rejection (70% vs 88%; NS). No correlation was found between serum sCD30 and anti-HLA class I antibodies or crossmatch positivity. In conclusion, neither pre- nor posttransplantation sCD30 levels were associated with acute rejection in liver transplant patients.

  5. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    Science.gov (United States)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-08-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R&D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  6. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    International Nuclear Information System (INIS)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-01-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R and D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion

  7. Online high sensitivity measurement system for transuranic aerosols

    International Nuclear Information System (INIS)

    Kordas, J.F.; Phelps, P.L.

    1976-01-01

    A measurement system for transuranic aerosols has been designed that will be able to withstand the corrosive nature of stack effluents and yet have extremely high sensitivity. It will be capable of measuring 1 maximum permissible concentration (MPC) of plutonium or americium in 30 minutes with a fractional standard deviation of less than 0.33. Background resulting from 218 Po is eliminated by alpha energy discrimination and a decay scheme analysis. A microprocessor controls all data acquisition, data reduction, and instrument calibration

  8. A Highly Sensitive Diagnostic System for Detecting Dengue Viruses Using the Interaction between a Sulfated Sugar Chain and a Virion.

    Directory of Open Access Journals (Sweden)

    Budi Saksono

    Full Text Available We propose a novel method of detecting trace amounts of dengue virus (DENVs from serum. Our method is based on the interaction between a sulfated sugar chain and a DENV surface glycoprotein. After capturing DENV with the sulfated sugar chain-immobilized gold nanoparticles (SGNPs, the resulting complex is precipitated and viral RNA content is measured using the reverse-transcription quantitative polymerase chain reaction SYBR Green I (RT-qPCR-Syb method. Sugar chains that bind to DENVs were identified using the array-type sugar chain immobilized chip (Sugar Chip and surface plasmon resonance (SPR imaging. Heparin and low-molecular-weight dextran sulfate were identified as binding partners, and immobilized on gold nanoparticles to prepare 3 types of SGNPs. The capacity of these SGNPs to capture and concentrate trace amounts of DENVs was evaluated in vitro. The SGNP with greatest sensitivity was tested using clinical samples in Indonesia in 2013-2014. As a result, the novel method was able to detect low concentrations of DENVs using only 6 μL of serum, with similar sensitivity to that of a Qiagen RNA extraction kit using 140 μL of serum. In addition, this method allows for multiplex-like identification of serotypes of DENVs. This feature is important for good healthcare management of DENV infection in order to safely diagnose the dangerous, highly contagious disease quickly, with high sensitivity.

  9. High Serum Adipocyte Fatty Acid Binding Protein Is Associated with Metabolic Syndrome in Patients with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Jer-Chuan Li

    2016-01-01

    Full Text Available Adipocyte fatty acid binding protein (A-FABP is a key mediator of obesity-related metabolic syndrome (MetS. The aim of this study was to evaluate the relationship between A-FABP concentration and MetS in type 2 diabetes mellitus (DM patients. Fasting blood samples were obtained from 165 type 2 DM volunteers. MetS and its components were defined using diagnostic criteria from the International Diabetes Federation. Among 165 DM patients, 113 patients (68.5% had MetS. Diabetic persons who had MetS had significantly higher A-FABP levels (P<0.001 than those without MetS. Female DM persons had higher A-FABP level than man (P<0.001. No statistically significant differences in A-FABP levels were found in use of statin, fibrate, or antidiabetic drugs. Multivariate forward stepwise linear regression analysis revealed that body fat mass (P<0.001, logarithmically transformed creatinine (log-creatinine; P<0.001, female DM patients (P<0.001, and logarithmically transformed high sensitive C-reactive protein (log-hs-CRP; P=0.013 were positively correlated, while albumin (P=0.004 and glomerular filtration rate (GFR; P=0.043 were negatively correlated with serum A-FABP levels in type 2 DM patients. In this study, higher serum A-FABP level was positively associated with MetS in type 2 DM patients.

  10. Recent trends in high spin sensitivity magnetic resonance

    Science.gov (United States)

    Blank, Aharon; Twig, Ygal; Ishay, Yakir

    2017-07-01

    new ideas, show how these limiting factors can be mitigated to significantly improve the sensitivity of induction detection. Finally, we outline some directions for the possible applications of high-sensitivity induction detection in the field of electron spin resonance.

  11. A novel photoelectrochemical immunosensor by integration of nanobody and TiO₂ nanotubes for sensitive detection of serum cystatin C.

    Science.gov (United States)

    Mi, Li; Wang, Pingyan; Yan, Junrong; Qian, Jing; Lu, Jusheng; Yu, Jiachao; Wang, Yuzhen; Liu, Hong; Zhu, Min; Wan, Yakun; Liu, Songqin

    2016-01-01

    Cystatin C (CysC) is a sensitive marker for the estimation of the glomerular filtration rate and the clinical diagnosis of different diseases. In this paper, CysC-specific nanobodies (Nbs) were isolated from a phage display nanobody library. A simple and sensitive photoelectrochemical immunosensor based on TiO2 nanotube arrays (TNAs) was proposed for the sensitive detection of CysC. The TiO2 nanotube arrays deposited by electrochemical anodization displayed a high and stable photocurrent response under irradiation. After coupling CysC-specific nanobody to TNA (Nb/TNA), the proposed immunosensor for CysC can be utilized for tracking the photocurrent change of Nb/TNA caused by immunoreactions between CysC and the immobilized CysC-specific Nb. This allowed for the determination of CysC with a calibration range from 0.72 pM to 7.19 nM. The variation of the photocurrent was in a linear relationship with the logarithm of the CysC concentration in the range of 0.72 pM-3.6 nM. The immunosensor had a correlation coefficient of 0.97 and a detection limit of 0.14 pM at a signal-to-noise ratio of 3. The proposed immunosensor showed satisfactory intra- and inter-assay accuracy, high selectivity and good stability. As a result, this proposed strategy would offer a novel and simple approach for the detection of immunoreactions, provide new insights in popularizing the diagnosis of CysC, and extend the application of TiO2 nanotubes. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Sensitive and selective spectrophotometric assay of piroxicam in pure form, capsule and human blood serum samples via ion-pair complex formation

    Science.gov (United States)

    Alizadeh, Nina; Keyhanian, Fereshteh

    2014-09-01

    A simple, accurate and highly sensitive spectrophotometric method has been developed for the rapid determination of piroxicam (PX) in pure and pharmaceutical formulations. The proposed method involves formation of stable yellow colored ion-pair complexes of the amino derivative (basic nitrogen) of PX with three sulphonphthalein acid dyes namely; bromocresol green (BCG), bromothymol blue (BTB), bromophenol blue (BPB) in acidic medium. The colored species exhibited absorption maxima at 438, 429 and 432 nm with molar absorptivity values of 9.400 × 103, 1.218 × 103 and 1.02 × 104 L mol-1 cm-1 for PX-BCG, PX-BTB and PX-BPB complexes, respectively. The effect of optimum conditions via acidity, reagent concentration, time and solvent were studied. The reactions were extremely rapid at room temperature and the absorbance values remained constant for 48 h. Beer’s law was obeyed with a good correlation coefficient in the concentration ranges 1-100 μg mL-1 for BCG, BTB complexes and 1-95 μg mL-1 for BPB complex. The composition ratio of the ion-pair complexes were found to be 1:1 in all cases as established by Job’s method. No interference was observed from common additives and excipients which may be present in the pharmaceutical preparations. The proposed method was successfully applied for the determination of PX in capsule and human blood serum samples with good accuracy and precision.

  13. In Vitro Selection of Single-Stranded DNA Molecular Recognition Elements against S. aureus Alpha Toxin and Sensitive Detection in Human Serum

    Directory of Open Access Journals (Sweden)

    Ka L. Hong

    2015-01-01

    Full Text Available Alpha toxin is one of the major virulence factors secreted by Staphylococcus aureus, a bacterium that is responsible for a wide variety of infections in both community and hospital settings. Due to the prevalence of S. aureus related infections and the emergence of methicillin-resistant S. aureus, rapid and accurate diagnosis of S. aureus infections is crucial in benefiting patient health outcomes. In this study, a rigorous Systematic Evolution of Ligands by Exponential Enrichment (SELEX variant previously developed by our laboratory was utilized to select a single-stranded DNA molecular recognition element (MRE targeting alpha toxin with high affinity and specificity. At the end of the 12-round selection, the selected MRE had an equilibrium dissociation constant (Kd of 93.7 ± 7.0 nM. Additionally, a modified sandwich enzyme-linked immunosorbent assay (ELISA was developed by using the selected ssDNA MRE as the toxin-capturing element and a sensitive detection of 200 nM alpha toxin in undiluted human serum samples was achieved.

  14. High-sensitivity bend angle measurements using optical fiber gratings.

    Science.gov (United States)

    Rauf, Abdul; Zhao, Jianlin; Jiang, Biqiang

    2013-07-20

    We present a high-sensitivity and more flexible bend measurement method, which is based on the coupling of core mode to the cladding modes at the bending region in concatenation with optical fiber grating serving as band reflector. The characteristics of a bend sensing arm composed of bending region and optical fiber grating is examined for different configurations including single fiber Bragg grating (FBG), chirped FBG (CFBG), and double FBGs. The bend loss curves for coated, stripped, and etched sections of fiber in the bending region with FBG, CFBG, and double FBG are obtained experimentally. The effect of separation between bending region and optical fiber grating on loss is measured. The loss responses for single FBG and CFBG configurations are compared to discover the effectiveness for practical applications. It is demonstrated that the sensitivity of the double FBG scheme is twice that of the single FBG and CFBG configurations, and hence acts as sensitivity multiplier. The bend loss response for different fiber diameters obtained through etching in 40% hydrofluoric acid, is measured in double FBG scheme that resulted in a significant increase in the sensitivity, and reduction of dead-zone.

  15. Increased serum levels of high mobility group box 1 protein in patients with autistic disorder.

    Science.gov (United States)

    Emanuele, Enzo; Boso, Marianna; Brondino, Natascia; Pietra, Stefania; Barale, Francesco; Ucelli di Nemi, Stefania; Politi, Pierluigi

    2010-05-30

    High mobility group box 1 (HMGB1) is a highly conserved, ubiquitous protein that functions as an activator for inducing the immune response and can be released from neurons after glutamate excitotoxicity. The objective of the present study was to measure serum levels of HMGB1 in patients with autistic disorder and to study their relationship with clinical characteristics. We enrolled 22 adult patients with autistic disorder (mean age: 28.1+/-7.7 years) and 28 age- and gender-matched healthy controls (mean age: 28.7+/-8.1 years). Serum levels of HMGB1 were measured by enzyme-linked immunosorbent assay (ELISA). Compared with healthy subjects, serum levels of HMGB1 were significantly higher in patients with autistic disorder (10.8+/-2.6 ng/mL versus 5.6+/-2.5 ng/mL, respectively, Pautistic disorder. Increased HMGB1 may be a biological correlate of the impaired reciprocal social interactions in this neurodevelopmental disorder. Copyright 2010 Elsevier Inc. All rights reserved.

  16. Serum induced degradation of 3D DNA box origami observed by high speed atomic force microscope

    DEFF Research Database (Denmark)

    Jiang, Zaixing; Zhang, Shuai; Yang, Chuanxu

    2015-01-01

    3D DNA origami holds tremendous potential to encapsulate and selectively release therapeutic drugs. Observations of real-time performance of 3D DNA origami structures in physiological environment will contribute much to its further applications. Here, we investigate the degradation kinetics of 3D...... DNA box origami in serum using high-speed atomic force microscope optimized for imaging 3D DNA origami in real time. The time resolution allows characterizing the stages of serum effects on individual 3D DNA box origami with nanometer resolution. Our results indicate that the whole digest process...... is a combination of a rapid collapse phase and a slow degradation phase. The damages of box origami mainly happen in the collapse phase. Thus, the structure stability of 3D DNA box origami should be further improved, especially in the collapse phase, before clinical applications...

  17. Immobilization of Bovine Serum Albumin Upon Multiwall Carbon Nanotube for High Speed Humidity Sensing Application.

    Science.gov (United States)

    Bhattacharya, Sankhya; Sasmal, Milan

    2016-01-01

    We present a high-speed humidity sensor based on immobilization of bovine serum albumin upon multiwall carbon nanotube (IBC). A simple and versatile drop casting technique was employed to make the humidity sensor using novel material IBC at room temperature. IBC was synthesized using easy solution process technique. The working principle of the IBC humidity sensor depends upon the variation of output current or conductance with the exposure of different humidity level. Humidity sensing properties of our device is explained on the basis of charge transfer from water molecules to IBC and bovine serum albumin to multiwall carbon nanotube (MWCNT). Our sensor exhibits faster response time around 1.2 s and recovery time 1.5 s respectively.

  18. Towards highly sensitive strain sensing based on nanostructured materials

    International Nuclear Information System (INIS)

    Dao, Dzung Viet; Nakamura, Koichi; Sugiyama, Susumu; Bui, Tung Thanh; Dau, Van Thanh; Yamada, Takeo; Hata, Kenji

    2010-01-01

    This paper presents our recent theoretical and experimental study of piezo-effects in nanostructured materials for highly sensitive, high resolution mechanical sensors. The piezo-effects presented here include the piezoresistive effect in a silicon nanowire (SiNW) and single wall carbon nanotube (SWCNT) thin film, as well as the piezo-optic effect in a Si photonic crystal (PhC) nanocavity. Firstly, the electronic energy band structure of the silicon nanostructure is discussed and simulated by using the First-Principles Calculations method. The result showed a remarkably different energy band structure compared with that of bulk silicon. This difference in the electronic state will result in different physical, chemical, and therefore, sensing properties of silicon nanostructures. The piezoresistive effects of SiNW and SWCNT thin film were investigated experimentally. We found that, when the width of ( 110 ) p-type SiNW decreases from 500 to 35 nm, the piezoresistive effect increases by more than 60%. The longitudinal piezoresistive coefficient of SWCNT thin film was measured to be twice that of bulk p-type silicon. Finally, theoretical investigations of the piezo-optic effect in a PhC nanocavity based on Finite Difference Time Domain (FDTD) showed extremely high resolution strain sensing. These nanostructures were fabricated based on top-down nanofabrication technology. The achievements of this work are significant for highly sensitive, high resolution and miniaturized mechanical sensors

  19. High serum level of the soluble CD30 identifies Chinese kidney transplant recipients at high risk of unfavorable outcome.

    Science.gov (United States)

    Iv, R; He, Q; Wang, H P; Jin, J; Chen, Y; Chen, J H

    2008-12-01

    We sought to investigate the relationship between serum level of sCD30 and recipient/graft survival rates, rejection types, as well as other prognostic factors among Chinese kidney transplant patients. We performed enzyme-linked immunosorbent assays of serum sCD30 levels in duplicate among retrospective cohort of 707 renal transplant patients. The incidences of rejection increased in relation to the pretransplant sCD30 level. The reversal rates of rejection were 100%, 90.6%, and 78.6% for the low, intermediate, and high sCD30 groups. This observation suggested that high levels of sCD30 and pretransplant panel-reactive antibody (PRA)-positive patients are risk factors for acute rejection with odds ratios of 6.862 and 1.756. High sCD30 was an independent risk factor for functional graft survival. The 5-year graft survival rates were 99.39% +/- 6.1%, 93.11% +/- 1.93%, and 82.07% +/- 3.97% among the low, intermediate, and high sCD30 groups, while the 5-year recipient survival rates were 89.25% +/- 2.41%, 91.82% +/- 1.64%, and 88.85% +/- 2.36%, respectively. Increased sCD30 levels were observed among patients who were PRA-positive, cytomegalovirus antigens or antibodies positive, on long-term dialysis, and sCD30 serum levels reflect immune status.

  20. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    Koetke, D.D.

    1992-01-01

    The work done on this project was focussed mainly on LAMPF experiment E969 known as the MEGA experiment, a high sensitivity search for the lepton family number violating decay μ → eγ to a sensitivity which, measured in terms of the branching ratio, BR = [μ→eγ]/[μ→e ν μ ν e ] ∼10 -13 is over two orders of magnitude better than previously reported values. The work done on MEGA during this period was divided between that done at Valparaiso University and that done at LAMPF. In addition, some contributions were made to a proposal to the LAMPF PAC to perform a precision measurement of the Michel ρ parameter, described below

  1. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    1994-01-01

    The work done on this project focused on two LAMPF experiments. The MEGA experiment is a high-sensitivity search for the lepton family number violating decay μ → eγ to a sensitivity which, measured in terms of the branching ratio, BR = [μ → eγ]/[μ eν μ ν e ] ∼ 10 -13 , will be over two orders of magnitude better than previously reported values. The second is a precision measurement of the Michel ρ parameter from the positron energy spectrum of μ → eν μ ν e to test the predictions V-A theory of weak interactions. In this experiment the uncertainty in the measurement of the Michel ρ parameter is expected to be a factor of three lower than the present reported value. The detectors are operational, and data taking has begun

  2. High sensitivity tests of the standard model for electroweak interactions

    International Nuclear Information System (INIS)

    Koetke, D.D.; Manweiler, R.W.; Shirvel Stanislaus, T.D.

    1993-01-01

    The work done on this project was focused on two LAMPF experiments. The MEGA experiment, a high-sensitivity search for the lepton-family-number-violating decay μ → e γ to a sensitivity which, measured in terms of the branching ratio, BR = [μ → e γ]/[μ → ev μ v e ] ∼ 10 -13 , is over two orders of magnitude better than previously reported values. The second is a precision measurement of the Michel ρ parameter from the positron energy spectrum of μ → ev μ v e to test the V-A theory of weak interactions. The uncertainty in the measurement of the Michel ρ parameter is expected to be a factor of three lower than the present reported value

  3. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  4. Development of miniature γ dose rate monitor with high sensitivity

    International Nuclear Information System (INIS)

    Shi Huilu; Tuo Xianguo; Xi Dashun; Tang Rong; Mu Keliang; Yang Jianbo

    2009-01-01

    This paper introduces a miniature γ dose rate monitor with high sensitivity which design based on single chip microcomputer, it can continue monitoring γ dose rate and then choose wire or wireless communications to sent the monitoring data to host according to the actual conditions. It has two kinds of power supply system, AC power supply system and battery which can be chose by concrete circumstances. The design idea and implementation technology of hardware and software and the system structure of the monitor are detailed illustrated in this paper. The experimental results show that measurable range is 0.1 mR/h-200 mR/h, the sensitivity of γ is 90 cps/mR/h, dead time below 200 us, error of stability below ±10%. (authors)

  5. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    Directory of Open Access Journals (Sweden)

    Yu Matsuda

    2016-04-01

    Full Text Available We propose a novel fast-responding and paintable pressure-sensitive paint (PSP based on polymer particles, i.e. polymer-particle (pp-PSP. As a fast-responding PSP, polymer-ceramic (PC-PSP is widely studied. Since PC-PSP generally consists of titanium (IV oxide (TiO2 particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  6. Integration of a highly ordered gold nanowires array with glucose oxidase for ultra-sensitive glucose detection

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Jiewu [NanoScience and Sensor Technology Research Group, School of Applied Sciences and Engineering, Monash University, Gippsland Campus, Churchill 3842, VIC Australia (Australia); Laboratory of Functional Nanomaterials and Devices, School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009, Anhui (China); Adeloju, Samuel B., E-mail: sam.adeloju@monash.edu [NanoScience and Sensor Technology Research Group, School of Applied Sciences and Engineering, Monash University, Gippsland Campus, Churchill 3842, VIC Australia (Australia); Wu, Yucheng, E-mail: ycwu@hfut.edu.cn [Laboratory of Functional Nanomaterials and Devices, School of Materials Science and Engineering, Hefei University of Technology, Hefei 230009, Anhui (China)

    2014-01-27

    Graphical abstract: -- Highlights: •Successfully synthesised highly-ordered gold nanowires array with an AAO template. •Fabricated an ultra-sensitive glucose nanobiosensor with the gold nanowires array. •Achieved sensitivity as high as 379.0 μA cm{sup −2} mM{sup −1} and detection limit as low as 50 nM. •Achieved excellent anti-interference with aid of Nafion membrane towards UA and AA. •Enabled successful detection and quantification of glucose in human blood serum. -- Abstract: A highly sensitive amperometric nanobiosensor has been developed by integration of glucose oxidase (GO{sub x}) with a gold nanowires array (AuNWA) by cross-linking with a mixture of glutaraldehyde (GLA) and bovine serum albumin (BSA). An initial investigation of the morphology of the synthesized AuNWA by field emission scanning electron microscopy (FESEM) and field emission transmission electron microscopy (FETEM) revealed that the nanowires array was highly ordered with rough surface, and the electrochemical features of the AuNWA with/without modification were also investigated. The integrated AuNWA–BSA–GLA–GO{sub x} nanobiosensor with Nafion membrane gave a very high sensitivity of 298.2 μA cm{sup −2} mM{sup −1} for amperometric detection of glucose, while also achieving a low detection limit of 0.1 μM, and a wide linear range of 5–6000 μM. Furthermore, the nanobiosensor exhibited excellent anti-interference ability towards uric acid (UA) and ascorbic acid (AA) with the aid of Nafion membrane, and the results obtained for the analysis of human blood serum indicated that the device is capable of glucose detection in real samples.

  7. Ultra-sensitive high performance liquid chromatography-laser-induced fluorescence based proteomics for clinical applications.

    Science.gov (United States)

    Patil, Ajeetkumar; Bhat, Sujatha; Pai, Keerthilatha M; Rai, Lavanya; Kartha, V B; Chidangil, Santhosh

    2015-09-08

    An ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique has been developed by our group at Manipal, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from volunteers (normal, and different pre-malignant/malignant conditions) were recorded using this set-up. The protein profiles were analyzed using principal component analysis (PCA) to achieve objective detection and classification of malignant, premalignant and healthy conditions with high sensitivity and specificity. The HPLC-LIF protein profiling combined with PCA, as a routine method for screening, diagnosis, and staging of cervical cancer and oral cancer, is discussed in this paper. In recent years, proteomics techniques have advanced tremendously in life sciences and medical sciences for the detection and identification of proteins in body fluids, tissue homogenates and cellular samples to understand biochemical mechanisms leading to different diseases. Some of the methods include techniques like high performance liquid chromatography, 2D-gel electrophoresis, MALDI-TOF-MS, SELDI-TOF-MS, CE-MS and LC-MS techniques. We have developed an ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from healthy and volunteers with different malignant conditions were recorded by using this set-up. The protein profile data were analyzed using principal component analysis (PCA) for objective

  8. Field test investigation of high sensitivity fiber optic seismic geophone

    Science.gov (United States)

    Wang, Meng; Min, Li; Zhang, Xiaolei; Zhang, Faxiang; Sun, Zhihui; Li, Shujuan; Wang, Chang; Zhao, Zhong; Hao, Guanghu

    2017-10-01

    Seismic reflection, whose measured signal is the artificial seismic waves ,is the most effective method and widely used in the geophysical prospecting. And this method can be used for exploration of oil, gas and coal. When a seismic wave travelling through the Earth encounters an interface between two materials with different acoustic impedances, some of the wave energy will reflect off the interface and some will refract through the interface. At its most basic, the seismic reflection technique consists of generating seismic waves and measuring the time taken for the waves to travel from the source, reflect off an interface and be detected by an array of geophones at the surface. Compared to traditional geophones such as electric, magnetic, mechanical and gas geophone, optical fiber geophones have many advantages. Optical fiber geophones can achieve sensing and signal transmission simultaneously. With the development of fiber grating sensor technology, fiber bragg grating (FBG) is being applied in seismic exploration and draws more and more attention to its advantage of anti-electromagnetic interference, high sensitivity and insensitivity to meteorological conditions. In this paper, we designed a high sensitivity geophone and tested its sensitivity, based on the theory of FBG sensing. The frequency response range is from 10 Hz to 100 Hz and the acceleration of the fiber optic seismic geophone is over 1000pm/g. sixteen-element fiber optic seismic geophone array system is presented and the field test is performed in Shengli oilfield of China. The field test shows that: (1) the fiber optic seismic geophone has a higher sensitivity than the traditional geophone between 1-100 Hz;(2) The low frequency reflection wave continuity of fiber Bragg grating geophone is better.

  9. A CMOS In-Pixel CTIA High Sensitivity Fluorescence Imager.

    Science.gov (United States)

    Murari, Kartikeya; Etienne-Cummings, Ralph; Thakor, Nitish; Cauwenberghs, Gert

    2011-10-01

    Traditionally, charge coupled device (CCD) based image sensors have held sway over the field of biomedical imaging. Complementary metal oxide semiconductor (CMOS) based imagers so far lack sensitivity leading to poor low-light imaging. Certain applications including our work on animal-mountable systems for imaging in awake and unrestrained rodents require the high sensitivity and image quality of CCDs and the low power consumption, flexibility and compactness of CMOS imagers. We present a 132×124 high sensitivity imager array with a 20.1 μm pixel pitch fabricated in a standard 0.5 μ CMOS process. The chip incorporates n-well/p-sub photodiodes, capacitive transimpedance amplifier (CTIA) based in-pixel amplification, pixel scanners and delta differencing circuits. The 5-transistor all-nMOS pixel interfaces with peripheral pMOS transistors for column-parallel CTIA. At 70 fps, the array has a minimum detectable signal of 4 nW/cm(2) at a wavelength of 450 nm while consuming 718 μA from a 3.3 V supply. Peak signal to noise ratio (SNR) was 44 dB at an incident intensity of 1 μW/cm(2). Implementing 4×4 binning allowed the frame rate to be increased to 675 fps. Alternately, sensitivity could be increased to detect about 0.8 nW/cm(2) while maintaining 70 fps. The chip was used to image single cell fluorescence at 28 fps with an average SNR of 32 dB. For comparison, a cooled CCD camera imaged the same cell at 20 fps with an average SNR of 33.2 dB under the same illumination while consuming over a watt.

  10. Highly sensitive detection of urinary cadmium to assess personal exposure

    Energy Technology Data Exchange (ETDEWEB)

    Argun, Avni A.; Banks, Ashley M.; Merlen, Gwendolynne; Tempelman, Linda A. [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States); Becker, Michael F.; Schuelke, Thomas [Fraunhofer USA – CCL, 1449 Engineering Research Ct., East Lansing 48824, MI (United States); Dweik, Badawi M., E-mail: bdweik@ginerinc.com [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States)

    2013-04-22

    Highlights: ► An electrochemical sensor capable of detecting cadmium at parts-per-billion levels in urine. ► A novel fabrication method for Boron-Doped Diamond (BDD) ultramicroelectrode (UME) arrays. ► Unique combination of BDD UME arrays and a differential pulse voltammetry algorithm. ► High sensitivity, high reproducibility, and very low noise levels. ► Opportunity for portable operation to assess on-site personal exposure. -- Abstract: A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb{sup −1} cm{sup −2}) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the U.S. National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25–1 ppb cadmium.

  11. Determination of serum IgD radioimmunoassay

    International Nuclear Information System (INIS)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l [fr

  12. Determination of serum IgD radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l.

  13. Serum Paraoxonase 1 Activity Is Associated with Fatty Acid Composition of High Density Lipoprotein

    Directory of Open Access Journals (Sweden)

    Maryam Boshtam

    2013-01-01

    Full Text Available Introduction. Cardioprotective effect of high density lipoprotein (HDL is, in part, dependent on its related enzyme, paraoxonase 1 (PON1. Fatty acid composition of HDL could affect its size and structure. On the other hand, PON1 activity is directly related to the structure of HDL. This study was designed to investigate the association between serum PON1 activity and fatty acid composition of HDL in healthy men. Methods. One hundred and forty healthy men participated in this research. HDL was separated by sequential ultracentrifugation, and its fatty acid composition was analyzed by gas chromatography. PON1 activity was measured spectrophotometrically using paraxon as substrate. Results. Serum PON1 activity was directly correlated with the amount of stearic acid and dihomo-gamma-linolenic acid (DGLA. PON1/HDL-C was directly correlated with the amount of miristic acid, stearic acid, and DGLA and was inversely correlated with total amount of ω6 fatty acids of HDL. Conclusion. The fatty acid composition of HDL could affect the activity of its associated enzyme, PON1. As dietary fats are the major determinants of serum lipids and lipoprotein composition, consuming some special dietary fatty acids may improve the activity of PON1 and thereby have beneficial effects on health.

  14. Serum paraoxonase 1 activity is associated with fatty acid composition of high density lipoprotein.

    Science.gov (United States)

    Boshtam, Maryam; Razavi, Amirnader Emami; Pourfarzam, Morteza; Ani, Mohsen; Naderi, Gholam Ali; Basati, Gholam; Mansourian, Marjan; Dinani, Narges Jafari; Asgary, Seddigheh; Abdi, Soheila

    2013-01-01

    Cardioprotective effect of high density lipoprotein (HDL) is, in part, dependent on its related enzyme, paraoxonase 1 (PON1). Fatty acid composition of HDL could affect its size and structure. On the other hand, PON1 activity is directly related to the structure of HDL. This study was designed to investigate the association between serum PON1 activity and fatty acid composition of HDL in healthy men. One hundred and forty healthy men participated in this research. HDL was separated by sequential ultracentrifugation, and its fatty acid composition was analyzed by gas chromatography. PON1 activity was measured spectrophotometrically using paraxon as substrate. Serum PON1 activity was directly correlated with the amount of stearic acid and dihomo-gamma-linolenic acid (DGLA). PON1/HDL-C was directly correlated with the amount of miristic acid, stearic acid, and DGLA and was inversely correlated with total amount of ω 6 fatty acids of HDL. The fatty acid composition of HDL could affect the activity of its associated enzyme, PON1. As dietary fats are the major determinants of serum lipids and lipoprotein composition, consuming some special dietary fatty acids may improve the activity of PON1 and thereby have beneficial effects on health.

  15. Serum Creatinine Versus Plasma Methotrexate Levels to Predict Toxicities in Children Receiving High-dose Methotrexate.

    Science.gov (United States)

    Tiwari, Priya; Thomas, M K; Pathania, Subha; Dhawan, Deepa; Gupta, Y K; Vishnubhatla, Sreenivas; Bakhshi, Sameer

    2015-01-01

    Facilities for measuring methotrexate (MTX) levels are not available everywhere, potentially limiting administration of high-dose methotrexate (HDMTX). We hypothesized that serum creatinine alteration after HDMTX administration predicts MTX clearance. Overall, 122 cycles in 50 patients of non-Hodgkin lymphoma or acute lymphoblastic leukemia aged ≤18 years receiving HDMTX were enrolled prospectively. Plasma MTX levels were measured at 12, 24, 36, 48, 60, and 72 hours; serum creatinine was measured at baseline, 24, 48, and 72 hours. Correlation of plasma MTX levels with creatinine levels and changes in creatinine from baseline (Δ creatinine) were evaluated. Plasma MTX levels at 72 hours showed positive correlation with serum creatinine at 48 hours (P = .011) and 72 hours (P = .013) as also Δ creatinine at 48 hours (P = .042) and 72 hours (P = .045). However, cut-off value of either creatinine or Δ creatinine could not be established to reliably predict delayed MTX clearance. Greater than 50% Δ creatinine at 48 and 72 hours significantly predicted grade 3/4 leucopenia (P = .036 and P = .001, respectively) and thrombocytopenia (P = .012 and P = .009, respectively) but not mucositis (P = .827 and P = .910, respectively). Delayed MTX elimination did not predict any grade 3/4 toxicity. In spite of demonstration of significant correlation between serum creatinine and Δ creatinine with plasma MTX levels at 72 hours, cut-off value of either variable to predict MTX delay could not be established. Thus, either of these cannot be used as a surrogate for plasma MTX estimation. Interestingly, Δ creatinine effectively predicted hematological toxicities, which were not predicted by delayed MTX clearance.

  16. High order effects in cross section sensitivity analysis

    International Nuclear Information System (INIS)

    Greenspan, E.; Karni, Y.; Gilai, D.

    1978-01-01

    Two types of high order effects associated with perturbations in the flux shape are considered: Spectral Fine Structure Effects (SFSE) and non-linearity between changes in performance parameters and data uncertainties. SFSE are investigated in Part I using a simple single resonance model. Results obtained for each of the resolved and for representative unresolved resonances of 238 U in a ZPR-6/7 like environment indicate that SFSE can have a significant contribution to the sensitivity of group constants to resonance parameters. Methods to account for SFSE both for the propagation of uncertainties and for the adjustment of nuclear data are discussed. A Second Order Sensitivity Theory (SOST) is presented, and its accuracy relative to that of the first order sensitivity theory and of the direct substitution method is investigated in Part II. The investigation is done for the non-linear problem of the effect of changes in the 297 keV sodium minimum cross section on the transport of neutrons in a deep-penetration problem. It is found that the SOST provides a satisfactory accuracy for cross section uncertainty analysis. For the same degree of accuracy, the SOST can be significantly more efficient than the direct substitution method

  17. Operationalization of the Russian Version of Highly Sensitive Person Scale

    Directory of Open Access Journals (Sweden)

    Регина Вячеславовна Ершова

    2018-12-01

    Full Text Available The aim of the present study was to operationalize a Russian version of the Highly Sensitive Person Scale (HSPS. The empirical data were collected in two ways: active, through oral advertising and inviting those who wish to take part in the study (snowball technique and passive (placement of ads about taking part in a research in social networks VKontakte and Facebook. As a result, 350 university students (117 men, 233 women, an average age of 18,2 (± 1,7 applied to a research laboratory and filled out the HSPS questionnaire, and another 510 respondents (380 women, 130 men, average age 22,6 ( ± 7,9 filled the HSPS online. The results of the study did not confirm the one-dimensional model of the construct, proposed by Aron & Aron (1997, as well as the most commonly used in the English-language studies three-factor solution. The hierarchical claster and confirmatory analyses used in the operationalization procedure allowed us to conclude that the variance of the Russian version of HSPS is best described in the framework of a two-factor model including the two separate subscales: Ease of Excitation (EOE, Low threshold of sensitivity (LTS. Sensory Processing Sensitivity may be defined as an increased susceptibility to external and internal stimuli, realized through negative emotional responses and deep susceptibility (distress to excessive stimulation.

  18. A wide-bandwidth and high-sensitivity robust microgyroscope

    International Nuclear Information System (INIS)

    Sahin, Korhan; Sahin, Emre; Akin, Tayfun; Alper, Said Emre

    2009-01-01

    This paper reports a microgyroscope design concept with the help of a 2 degrees of freedom (DoF) sense mode to achieve a wide bandwidth without sacrificing mechanical and electronic sensitivity and to obtain robust operation against variations under ambient conditions. The design concept is demonstrated with a tuning fork microgyroscope fabricated with an in-house silicon-on-glass micromachining process. When the fabricated gyroscope is operated with a relatively wide bandwidth of 1 kHz, measurements show a relatively high raw mechanical sensitivity of 131 µV (° s −1 ) −1 . The variation in the amplified mechanical sensitivity (scale factor) of the gyroscope is measured to be less than 0.38% for large ambient pressure variations such as from 40 to 500 mTorr. The bias instability and angle random walk of the gyroscope are measured to be 131° h −1 and 1.15° h −1/2 , respectively

  19. Development of an underwater high sensitivity Cherenkov detector: Sea Urchin

    International Nuclear Information System (INIS)

    Camerini, U.; McGibney, D.; Roberts, A.

    1982-01-01

    The need for a high gain, high sensitivity Cherenkov light sensor to be used in a deep underwater muon and neutrino detector (DUMAND) array has led to the design of the Sea Urchin detector. In this design a spherical photocathode PMTis optically coupled through a glass hemisphere to a large number of glass spines, each of which is filled with a wavelength-shifting (WLS) solution of a high quantum efficiency phosphor. The Cherenkov radiation is absorbed in the spine, isotropically re-radiated at a longer wavelength, and a fraction of the fluorescent light is internally reflected in the spine, and guided to the photomultiplier concentrically located in the glass hemisphere. Experiments measuring the optical characteristics of the spines and computer programs simulating light transformation and detection cross sections are described. Overall optical gains in the range 5-10 are achieved. The WLS solution is inexpensive, and may have other applications. (orig.)

  20. Position sensitive detection of neutrons in high radiation background field.

    Science.gov (United States)

    Vavrik, D; Jakubek, J; Pospisil, S; Vacik, J

    2014-01-01

    We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e(-) radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm(2)) spectroscopic Timepix detector adapted for neutron detection utilizing very thin (10)B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10(-4).

  1. Electrochemistry-based approaches to low cost, high sensitivity, automated, multiplexed protein immunoassays for cancer diagnostics.

    Science.gov (United States)

    Dixit, Chandra K; Kadimisetty, Karteek; Otieno, Brunah A; Tang, Chi; Malla, Spundana; Krause, Colleen E; Rusling, James F

    2016-01-21

    Early detection and reliable diagnostics are keys to effectively design cancer therapies with better prognoses. The simultaneous detection of panels of biomarker proteins holds great promise as a general tool for reliable cancer diagnostics. A major challenge in designing such a panel is to decide upon a coherent group of biomarkers which have higher specificity for a given type of cancer. The second big challenge is to develop test devices to measure these biomarkers quantitatively with high sensitivity and specificity, such that there are no interferences from the complex serum or tissue matrices. Lastly, integrating all these tests into a technology that does not require exclusive training to operate, and can be used at point-of-care (POC) is another potential bottleneck in futuristic cancer diagnostics. In this article, we review electrochemistry-based tools and technologies developed and/or used in our laboratories to construct low-cost microfluidic protein arrays for the highly sensitive detection of a panel of cancer-specific biomarkers with high specificity which at the same time has the potential to be translated into POC applications.

  2. Positive Correlation between Serum Osteocalcin and Testosterone in Male Hyperthyroidism Patients with High Bone Turnover.

    Science.gov (United States)

    Zhong, N; Xu, B; Cui, R; Xu, M; Su, J; Zhang, Z; Liu, Y; Li, L; Sheng, C; Sheng, H; Qu, S

    2016-07-01

    Animal studies suggested that there is an independent bone-osteocalcin-gonadal axis, except of the hypothalamic-pituitary-gonadal axis. Based on this hypothesis, the higher osteocalcin during the high bone turnover should be followed by higher testosterone formation. Yet such clinical evidence is limited. The patients with uncontrolled hyperthyroidism are proper model with high bone turnover. If this hypothesis is true, there should be high testosterone level in patients with uncontrolled hyperthyroidism. Therefore, Graves' disease patients were recruited to study the correlation between osteocalcin and testosterone. 50 male hyperthyroidism patients with Graves' disease and 50 health persons matched by age and gender were enrolled in our cross-section study. Serum markers for thyroid hormone, sex hormone and bone metabolic markers including free triiodothyronine (FT3), free thyroxine (FT4), thyroid-stimulating hormone (TSH), testosterone, luteinizing hormone (LH), follicle-stimulating hormone (FSH) and osteocalcin (OC), C-terminal telopeptide fragments of type I collagen (CTX) were examined. The demographic parameters such as duration of disease were also collected. All data was analyzed by SPSS 20.0. High testosterone and osteocalcin level was observed in the hyperthyroidism patients (T 36.35±10.72 nmol/l and OC 46.79±26.83 ng/ml). In simple Pearson correlation, testosterone was positively associated with OC (r=0.486, Phyperthyroidism patients, osteocalcin was positively correlated with serum testosterone, which indirectly supports the hypothesis that serum osteocalcin participates in the regulation of sex hormone. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Highly Sensitive Flexible Magnetic Sensor Based on Anisotropic Magnetoresistance Effect.

    Science.gov (United States)

    Wang, Zhiguang; Wang, Xinjun; Li, Menghui; Gao, Yuan; Hu, Zhongqiang; Nan, Tianxiang; Liang, Xianfeng; Chen, Huaihao; Yang, Jia; Cash, Syd; Sun, Nian-Xiang

    2016-11-01

    A highly sensitive flexible magnetic sensor based on the anisotropic magnetoresistance effect is fabricated. A limit of detection of 150 nT is observed and excellent deformation stability is achieved after wrapping of the flexible sensor, with bending radii down to 5 mm. The flexible AMR sensor is used to read a magnetic pattern with a thickness of 10 μm that is formed by ferrite magnetic inks. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. High sensitivity on-line monitor for radioactive effluent

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Toshimi [Tohoku Electric Power Co. Ltd., Sendai (Japan); Ishizuka, Akira; Abe, Eisuke; Inoue, Yasuhiko; Fujii, Masaaki; Kitaguchi, Hiroshi; Doi, Akira

    1983-04-01

    A new approach for a highly sensitive effluent monitor is presented. The free flow type monitor, which consists of a straightener, nozzle, monitoring section and ..gamma..-ray detector, is demonstrated to be effective in providing long term stability. The 160 start-and-stop cycles of effluent discharge were repeated in a 120-h testing period. Results showed a background increase was not observed for the free flow type monitor. The background count rate was calibrated to the lowest detection limit to be 2.2 x 10/sup -2/ Bq/ml for a 300 s measurement time.

  5. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  6. Fabrication of highly catalytic silver nanoclusters/graphene oxide nanocomposite as nanotag for sensitive electrochemical immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jiamian; Wang, Xiuyun; Wu, Shuo, E-mail: wushuo@dlut.edu.cn; Song, Jie; Zhao, Yanqiu; Ge, Yanqiu; Meng, Changgong

    2016-02-04

    Silver nanoclusters and graphene oxide nanocomposite (AgNCs/GRO) is synthesized and functionalized with detection antibody for highly sensitive electrochemical sensing of carcinoembryonic antigen (CEA), a model tumor marker involved in many cancers. AgNCs with large surface area and abundant amount of low-coordinated sites are synthesized with DNA as template and exhibit high catalytic activity towards the electrochemical reduction of H{sub 2}O{sub 2}. GRO is employed to assemble with AgNCs because it has large specific surface area, super electronic conductivity and strong π-π stacking interaction with the hydrophobic bases of DNA, which can further improve the catalytic ability of the AgNCs. Using AgNCs/GRO as signal amplification tag, an enzyme-free electrochemical immunosensing protocol is designed for the highly sensitive detection of CEA on the capture antibody functionalized immunosensing interface. Under optimal conditions, the designed immunosensor exhibits a wide linear range from 0.1 pg mL{sup −1} to 100 ng mL{sup −1} and a low limit of detection of 0.037 pg mL{sup −1}. Practical sample analysis reveals the sensor has good accuracy and reproducibility, indicating the great application prospective of the AgNCs/GRO in fabricating highly sensitive immunosensors, which can be extended to the detection of various kinds of low abundance disease related proteins. - Highlights: • An enzyme-free electrochemical immunosensor is reported for detecting proteins. • A silver nanocluster/graphene oxide composite is synthesized as nanotag. • The nanotags exhibit highly catalytic activity to the electro-reduction of H{sub 2}O{sub 2}. • The as-fabricated immunosensor could detect protein in serum samples.

  7. Moderate sensitivity and high specificity of emergency department administrative data for transient ischemic attacks.

    Science.gov (United States)

    Yu, Amy Y X; Quan, Hude; McRae, Andrew; Wagner, Gabrielle O; Hill, Michael D; Coutts, Shelagh B

    2017-09-18

    Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database. We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA. Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard. Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

  8. Sensitivity of Lyme Borreliosis Spirochetes to Serum Complement of Regular Zoo Animals: Potential Reservoir Competence of Some Exotic Vertebrates

    Czech Academy of Sciences Publication Activity Database

    Tichá, L.; Golovchenko, Maryna; Oliver, J. H., Jr.; Grubhoffer, Libor; Rudenko, Natalia

    2016-01-01

    Roč. 16, č. 1 (2016), s. 13-19 ISSN 1530-3667 EU Projects: European Commission(XE) 278976 - ANTIGONE Institutional support: RVO:60077344 Keywords : Borrelia burgdorferi sensu lato * Lyme disease * serum complement * exotic animals * reservoir hosts * zoo Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 2.045, year: 2016

  9. Determination of hexamethylmelamine and metabolites in plasma or serum by gas—liquid chromatography with a nitrogen-sensitive detector

    NARCIS (Netherlands)

    Hulshoff, A.; Neijt, J.P.; Smulders, C.F.A.; Loenen, A.C. van; Pinedo, H.M.

    1980-01-01

    A gas chromatographic method for the quantitative determination of hexamethylmelamine (HMM) and five of its metabolites in plasma (or serum) is described. After adjustment of the pH of the plasma sample to about 9.5, the compounds are extracted with chloroform containing 5% of isopropanol. Amyl

  10. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis

    Directory of Open Access Journals (Sweden)

    R.F. Vogel

    2005-08-01

    Full Text Available Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK, while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport.

  11. Consumption of blueberries with a high-carbohydrate, low-fat breakfast decreases postprandial serum markers of oxidation.

    Science.gov (United States)

    Blacker, Bryan C; Snyder, Shannon M; Eggett, Dennis L; Parker, Tory L

    2013-05-01

    We sought to determine whether consumption of blueberries could reduce postprandial oxidation when consumed with a typical high-carbohydrate, low-fat breakfast. Participants (n 14) received each of the three treatments over 3 weeks in a cross-over design. Treatments consisted of a high blueberry dose (75 g), a low blueberry dose (35 g) and a control (ascorbic acid and sugar content matching that of the high blueberry dose). Serum oxygen radical absorbance capacity (ORAC), serum lipoprotein oxidation (LO) and serum ascorbate, urate and glucose were measured at fasting, and at 1, 2 and 3 h after sample consumption. The mean serum ORAC was significantly higher in the 75 g group than in the control group during the first 2 h postprandially, while serum LO lag time showed a significant trend over the 3 h for both blueberry doses. Changes in serum ascorbate, urate and glucose were not significantly different among the groups. To our knowledge, this is the first report that has demonstrated that increased serum antioxidant capacity is not attributable to the fructose or ascorbate content of blueberries. In summary, a practically consumable quantity of blueberries (75 g) can provide statistically significant oxidative protection in vivo after a high-carbohydrate, low-fat breakfast. Though not tested directly, it is likely that the effects are due to phenolic compounds, either directly or indirectly, as they are a major family of compounds in blueberries with potential bioactive activity.

  12. Potential role of peroxisome proliferator activated receptor gamma activation on serum visfatin and trace elements in high fat diet induced type 2 diabetes mellitus.

    Science.gov (United States)

    Tabassum, Arshia; Zaidi, Syeda Nuzhat Fatima; Yasmeen, Kausar; Mahboob, Tabassum

    2018-07-15

    Electrolytes and trace elements dysregulation play an important role in the progression of obesity and diabetes complications. The present study was designed to evaluate the insulin sensitizing effects of peroxisomes proliferators activated receptor gamma (PPAR-γ) agonist on trace elements in obesity induced type 2 diabetes mellitus and correlate with serum visfatin. Wistar rats were categorized into five groups. Group I served as control; Group II fed on high fat diet (HFD); Group III fed on HFD and treated with rosiglitazone (3 mg/kg) for 7 days; Group IV were T2DM rats induce by HFD and low dose of streptozotocin (i.p. 35 mg/kg); Group V was T2DM rats treated with rosiglitazone (3 mg/kg) for 7 days. Serum and tissues electrolytes levels and renal, hepatic and cardiac tissues trace elements were estimated by flame photometer and atomic absorption spectroscopy. Serum visfatin was estimated by ELISA. Pearson correlations were analyzed among fasting blood glucose (FBG), serum visfatin and tissues trace elements. Results of the current study showed hyponatremia, hyperkalemia, hypomagnesemia and hypercalcemia in HFD and T2DM groups. HFD and T2DM also showed elevated copper and iron levels; however, zinc and selenium levels were decreased. Rosiglitazone treatment increased the insulin sensitization and altered these changes. A Strong association was observed among FBG, serum visfatin and trace elements levels of HFD and T2DM. Obesity and diabetes mellitus disturbed visfatin, electrolytes and trace elements homeostasis. Rosiglitazone treatment restored these changes. The results of the study could serve as a basis for further studies for the prevention of diabetic complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. A simple, tunable, and highly sensitive radio-frequency sensor.

    Science.gov (United States)

    Cui, Yan; Sun, Jiwei; He, Yuxi; Wang, Zheng; Wang, Pingshan

    2013-08-05

    We report a radio frequency (RF) sensor that exploits tunable attenuators and phase shifters to achieve high-sensitivity and broad band frequency tunability. Three frequency bands are combined to enable sensor operations from ∼20 MHz to ∼38 GHz. The effective quality factor ( Q eff ) of the sensor is as high as ∼3.8 × 10 6 with 200  μ l of water samples. We also demonstrate the measurement of 2-proponal-water-solution permittivity at 0.01 mole concentration level from ∼1 GHz to ∼10 GHz. Methanol-water solution and de-ionized water are used to calibrate the RF sensor for the quantitative measurements.

  14. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    Science.gov (United States)

    Brantjes, N. P. M.; Dzordzhadze, V.; Gebel, R.; Gonnella, F.; Gray, F. E.; van der Hoek, D. J.; Imig, A.; Kruithof, W. L.; Lazarus, D. M.; Lehrach, A.; Lorentz, B.; Messi, R.; Moricciani, D.; Morse, W. M.; Noid, G. A.; Onderwater, C. J. G.; Özben, C. S.; Prasuhn, D.; Levi Sandri, P.; Semertzidis, Y. K.; da Silva e Silva, M.; Stephenson, E. J.; Stockhorst, H.; Venanzoni, G.; Versolato, O. O.

    2012-02-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY at Jülich. By measuring with very high statistical precision, the contributions that are second-order in the systematic errors become apparent. By calibrating the sensitivity of the polarimeter to such errors, it becomes possible to obtain information from the raw count rate values on the size of the errors and to use this information to correct the polarization measurements. During the experiment, it was possible to demonstrate that corrections were satisfactory at the level of 10 -5 for deliberately large errors. This may facilitate the real time observation of vector polarization changes smaller than 10 -6 in a search for an electric dipole moment using a storage ring.

  15. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    Energy Technology Data Exchange (ETDEWEB)

    Brantjes, N.P.M. [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Dzordzhadze, V. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Gebel, R. [Institut fuer Kernphysik, Juelich Center for Hadron Physics, Forschungszentrum Juelich, D-52425 Juelich (Germany); Gonnella, F. [Physica Department of ' Tor Vergata' University, Rome (Italy); INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Gray, F.E. [Regis University, Denver, CO 80221 (United States); Hoek, D.J. van der [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Imig, A. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Kruithof, W.L. [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Lazarus, D.M. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Lehrach, A.; Lorentz, B. [Institut fuer Kernphysik, Juelich Center for Hadron Physics, Forschungszentrum Juelich, D-52425 Juelich (Germany); Messi, R. [Physica Department of ' Tor Vergata' University, Rome (Italy); INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Moricciani, D. [INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Morse, W.M. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Noid, G.A. [Indiana University Cyclotron Facility, Bloomington, IN 47408 (United States); and others

    2012-02-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY at Juelich. By measuring with very high statistical precision, the contributions that are second-order in the systematic errors become apparent. By calibrating the sensitivity of the polarimeter to such errors, it becomes possible to obtain information from the raw count rate values on the size of the errors and to use this information to correct the polarization measurements. During the experiment, it was possible to demonstrate that corrections were satisfactory at the level of 10{sup -5} for deliberately large errors. This may facilitate the real time observation of vector polarization changes smaller than 10{sup -6} in a search for an electric dipole moment using a storage ring.

  16. Wide bandwidth transimpedance amplifier for extremely high sensitivity continuous measurements.

    Science.gov (United States)

    Ferrari, Giorgio; Sampietro, Marco

    2007-09-01

    This article presents a wide bandwidth transimpedance amplifier based on the series of an integrator and a differentiator stage, having an additional feedback loop to discharge the standing current from the device under test (DUT) to ensure an unlimited measuring time opportunity when compared to switched discharge configurations while maintaining a large signal amplification over the full bandwidth. The amplifier shows a flat response from 0.6 Hz to 1.4 MHz, the capability to operate with leakage currents from the DUT as high as tens of nanoamperes, and rail-to-rail dynamic range for sinusoidal current signals independent of the DUT leakage current. Also available is a monitor output of the stationary current to track experimental slow drifts. The circuit is ideal for noise spectral and impedance measurements of nanodevices and biomolecules when in the presence of a physiological medium and in all cases where high sensitivity current measurements are requested such as in scanning probe microscopy systems.

  17. Design of a charge sensitive preamplifier on high resistivity silicon

    International Nuclear Information System (INIS)

    Radeka, V.; Rehak, P.; Rescia, S.; Gatti, E.; Longoni, A.; Sampietro, M.; Holl, P.; Strueder, L.; Kemmer, J.

    1987-01-01

    A low noise, fast charge sensitive preamplifier was designed on high resistivity, detector grade silicon. It is built at the surface of a fully depleted region of n-type silicon. This allows the preamplifier to be placed very close to a detector anode. The preamplifier uses the classical input cascode configuration with a capacitor and a high value resistor in the feedback loop. The output stage of the preamplifier can drive a load up to 20pF. The power dissipation of the preamplifier is 13mW. The amplifying elements are ''Single Sided Gate JFETs'' developed especially for this application. Preamplifiers connected to a low capacitance anode of a drift type detector should achieve a rise time of 20ns and have an equivalent noise charge (ENC), after a suitable shaping, of less than 50 electrons. This performance translates to a position resolution better than 3μm for silicon drift detectors. 6 refs., 9 figs

  18. High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors.

    Science.gov (United States)

    Sarangadharan, Indu; Regmi, Abiral; Chen, Yen-Wen; Hsu, Chen-Pin; Chen, Pei-Chi; Chang, Wen-Hsin; Lee, Geng-Yen; Chyi, Jen-Inn; Shiesh, Shu-Chu; Lee, Gwo-Bin; Wang, Yu-Lin

    2018-02-15

    In this study, we report the development of a high sensitivity assay for the detection of cardiac troponin I using electrical double layer gated high field AlGaN/GaN HEMT biosensor. The unique gating mechanism overcomes the drawback of charge screening seen in traditional FET based biosensors, allowing detection of target proteins in physiological solutions without sample processing steps. Troponin I specific antibody and aptamer are used as receptors. The tests carried out using purified protein solution and clinical serum samples depict high sensitivity, specificity and wide dynamic range (0.006-148ng/mL). No additional wash or sample pre-treatment steps are required, which greatly simplifies the biosensor system. The miniaturized HEMT chip is packaged in a polymer substrate and easily integrated with a portable measurement unit, to carry out quantitative troponin I detection in serum samples with < 2µl sample volume in 5min. The integrated prototype biosensor unit demonstrates the potential of the method as a rapid, inexpensive, high sensitivity CVD biomarker assay. The highly simplified protocols and enhanced sensor performance make our biosensor an ideal choice for point of care diagnostics and personal healthcare systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. High serum levels of YKL-40 in patients with squamous cell carcinoma of the head and neck are associated with short survival

    DEFF Research Database (Denmark)

    Roslind, Anne; Johansen, Julia S; Christensen, Ib J

    2008-01-01

    by immunohistochemistry in 50 patients. Pretreatment serum YKL-40 was elevated in 53%. Patients with high serum YKL-40 had shorter survival than patients with normal serum YKL-40 (33 vs. 84 months; p = 0.008). Multivariate Cox analysis including pretreatment serum YKL-40, age, sex, primary tumor site, TNM classification...... and treatment demonstrated that TNM classification (HR = 2.61, p = 0.02) and serum YKL-40 (log-transformed continuous variable: HR = 1.55, p...

  20. Development and validation of a rapid, selective, and sensitive LC-MS/MS method for simultaneous determination of D- and L-amino acids in human serum: application to the study of hepatocellular carcinoma.

    Science.gov (United States)

    Han, Minlu; Xie, Mengyu; Han, Jun; Yuan, Daoyi; Yang, Tian; Xie, Ying

    2018-04-01

    A validated liquid chromatography-tandem mass spectrometry method was developed for the simultaneous determination of D- and L-amino acids in human serum. Under the optimum conditions, except for DL-proline, L-glutamine, and D-lysine, the enantioseparation of the other 19 enantiomeric pairs of proteinogenic amino acids and nonchiral glycine was achieved with a CROWNPAK CR-I(+) chiral column within 13 min. The lower limits of quantitation for L-amino acids (including glycine) and D-amino acids were 5-56.25 μM and 0.625-500 nM, respectively, in human serum. The intraday precision and interday precision for all the analytes were less than 15%, and the accuracy ranged from -12.84% to 12.37% at three quality control levels. The proposed method, exhibiting high rapidity, enantioresolution, and sensitivity, was successfully applied to the quantification of D- and L-amino acid levels in serum from hepatocellular carcinoma patients and healthy individuals. The serum concentrations of L-arginine, L-isoleucine, L-aspartate, L-tryptophan, L-alanine, L-methionine, L-serine, glycine, L-valine, L-leucine, L-phenylalanine, L-threonine, D-isoleucine, D-alanine, D-glutamate, D-glutamine, D-methionine, and D-threonine were significantly reduced in the hepatocellular carcinoma patients compared with the healthy individuals (P hepatocellular carcinoma research. Graphical abstract Simultaneous determination of D- and L-amino acids in human serum from hepatocellular carcinoma patients and healthy individuals. AA amino acid, HCC hepatocellular carcinoma, LC liquid chromatography, MS/MS tandem mass spectrometry, NC normal control, TIC total ion chromatogram.

  1. Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection.

    Science.gov (United States)

    Inoue, K; Kato, K; Yoshimura, Y; Makino, T; Nakazawa, H

    2000-11-10

    A simple and sensitive method using high-performance liquid chromatography with multi-electrode electrochemical detection (HPLC-ED) including a coulometric array of four electrochemical sensors has been developed for the determination of bisphenol A in water and human serum. For good separation and detection of bisphenol A, a CAPCELL PAK UG 120 C18 reversed-phase column and a mobile phase consisting of 0.3% phosphoric acid-acetonitrile (60:40) were used. The detection limit obtained by the HPLC-ED method was 0.01 ng/ml (0.5 pg), which was more than 3000-times higher than the detection limit obtained by the ultraviolet (UV) method, and more than 200-times higher than the detection limit obtained by the fluorescence (FL) method. Bisphenol A in water and serum samples was pretreated by solid-phase extraction (SPE) after removing possible contamination derived from a plastic SPE cartridges and water used for the pretreatment. A trace amount (ND approximately 0.013 ng/ml) of bisphenol A was detected from the parts of cartridges (filtration column, sorbent bed and frits) by extraction with methanol, and it was completely removed by washing with at least 15 ml of methanol in the operation process. The concentrations of bisphenol A in tap water and Milli-Q-purified water were found to be 0.01 and 0.02 ng/ml, respectively. For that reason, bisphenol A-free water was made to trap bisphenol A in water using an Empore disk. In every pretreatment, SPE methods using bisphenol A-free water and washing with 15 ml of methanol were done in water and serum samples. The yields obtained from the recovery tests using water to which 0.5 or 0.05 ng/ml of bisphenol A was added were 83.8 to 98.2%, and the RSDs were 3.4 to 6.1%, respectively. The yields obtained from the recovery tests by OASIS HLB using serum to which 1.0 ng/ml or 0.1 ng/ml of bisphenol A was added were 79.0% and 87.3%, and the RSDs were 5.1% and 13.5%, respectively. The limits of quantification in water and serum sample

  2. High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Singh, Harpal; Morita, Takahiro; Suzuki, Yuma; Shimojima, Masayuki; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked immunosorbent assays (ELISA) are considered the gold standard in the demonstration of various immunological reactions with an application in the detection of infectious diseases such as during outbreaks or in patient care. This study aimed to produce an ELISA-based diagnostic with an increased sensitivity of detection compared to the standard 96-well method in the immunologic diagnosis of infectious diseases. A '3DStack' was developed using readily available, low cost fabrication technologies namely nanoimprinting and press stamping with an increased surface area of 4 to 6 times more compared to 96-well plates. This was achieved by stacking multiple nanoimprinted polymer sheets. The flow of analytes between the sheets was enhanced by rotating the 3DStack and confirmed by Finite-Element (FE) simulation. An Immunoglobulin G (IgG) ELISA for the detection of antibodies in human serum raised against Rubella virus was performed for validation. An improved sensitivity of up to 1.9 folds higher was observed using the 3DStack compared to the standard method. The increased surface area of the 3DStack developed using nanoimprinting and press stamping technologies, and the flow pattern between sheets generated by rotating the 3DStack were potential contributors to a more sensitive ELISA-based diagnostic device.

  3. High serum uric acid levels are a protective factor against unfavourable neurological functional outcome in patients with ischaemic stroke.

    Science.gov (United States)

    Wang, Yu-Fang; Li, Jiao-Xing; Sun, Xun-Sha; Lai, Rong; Sheng, Wen-Li

    2018-05-01

    Objective We aimed to evaluate the association between serum uric acid levels at the onset and prognostic outcome in patients with acute ischaemic stroke. Methods We retrospectively analysed the outcomes of 1166 patients with ischaemic stroke who were hospitalized in our centre during August 2008 to November 2012. Correlations of serum uric acid levels and prognostic outcomes were analysed. Results Men had higher serum uric acid levels and better neurological functional outcomes compared with women. There was a strong negative correlation between serum uric acid levels and unfavourable neurological functional outcomes. Generalized estimated equation analysis showed that a higher serum uric acid level (>237 µmol/L) was a protective factor for neurological functional outcome in male, but not female, patients. Among five trial of ORG 10172 in acute stroke treatment classification subtypes, only patients with the large-artery atherosclerosis subtype had a significant protective effect of serum uric acid levels on neurological outcome. Conclusions Our study shows that high serum uric acid levels are a significant protective factor in men and in the large-artery atherosclerosis subtype in patients with ischaemic stroke. This is helpful for determining the prognostic value of serum uric acid levels for neurological outcome of acute ischaemic stroke.

  4. High-Sensitivity Temperature-Independent Silicon Photonic Microfluidic Biosensors

    Science.gov (United States)

    Kim, Kangbaek

    Optical biosensors that can precisely quantify the presence of specific molecular species in real time without the need for labeling have seen increased use in the drug discovery industry and molecular biology in general. Of the many possible optical biosensors, the TM mode Si biosensor is shown to be very attractive in the sensing application because of large field amplitude on the surface and cost effective CMOS VLSI fabrication. Noise is the most fundamental factor that limits the performance of sensors in development of high-sensitivity biosensors, and noise reduction techniques require precise studies and analysis. One such example stems from thermal fluctuations. Generally SOI biosensors are vulnerable to ambient temperature fluctuations because of large thermo-optic coefficient of silicon (˜2x10 -4 RIU/K), typically requiring another reference ring and readout sequence to compensate temperature induced noise. To address this problem, we designed sensors with a novel TM-mode shallow-ridge waveguide that provides both large surface amplitude for bulk and surface sensing. With proper design, this also provides large optical confinement in the aqueous cladding that renders the device athermal using the negative thermo-optic coefficient of water (~ --1x10-4RIU/K), demonstrating cancellation of thermo-optic effects for aqueous solution operation near 300K. Additional limitations resulting from mechanical actuator fluctuations, stability of tunable lasers, and large 1/f noise of lasers and sensor electronics can limit biosensor performance. Here we also present a simple harmonic feedback readout technique that obviates the need for spectrometers and tunable lasers. This feedback technique reduces the impact of 1/f noise to enable high-sensitivity, and a DSP lock-in with 256 kHz sampling rate can provide down to micros time scale monitoring for fast transitions in biomolecular concentration with potential for small volume and low cost. In this dissertation, a novel

  5. Expression of human apolipoprotein A-I epitopes in high density lipoproteins and in serum

    International Nuclear Information System (INIS)

    Marcel, Y.L.; Jewer, D.; Vezina, C.; Milthorp, P.; Weech, P.K.

    1987-01-01

    The expression and immunoreactivity of apolipoprotein (apo) A-I epitopes in high density lipoproteins (HDL) and serum has been investigated using two series of monoclonal antibodies (Mabs) which have been described elsewhere. Series 1 Mabs, identified as 3D4, 6B8, and 5G6, were obtained by immunization and screening with apoA-I, and series 2 Mabs, identified as 2F1, 4H1, 3G10, 4F7, and 5F6, were obtained by immunization and screening with HDL. These Mabs were characterized with respect to their binding to HDL particles in solution. In series 2 Mabs, 2F1, 3G10, and 4F7, which react with apoA-I CNBr-fragments 1 and 2, could precipitate 100% of 125 I-labeled HDL, while 4H1 and 5F6, which react with CNBr fragments 1 and 3, precipitated 90 and 60% of 125 I-labeled HDL, respectively. Therefore, three distinct epitopes mapped to CNBr fragments 1 and 2 have been identified which are expressed on all HDL particles, indicating that several antigenic do mains exist on apoA-I which have the same conformation on all apoA-I-containing lipoproteins. The Mabs reacting at these sites have significantly higher affinity constants for 125 I-labeled HDL than those that failed to precipitate 100% of HDL. This suggests that the high affinity Mabs react with apoA-I epitopes that are both expressed on all lipoproteins and located in thermo-dynamically stable regions of the molecules. All Mabs from series 1 precipitated 35% or less of 125 I-labeled HDL prepared from freshly collected serum, but the proportion of HDL particles expressing the epitopes for these Mabs doubled or more upon serum storage at 4 degrees C. The time course of the alteration of apoA-I antigen in vitro was measured in three normolipemic donors

  6. High sensitivity pyrogen testing in water and dialysis solutions.

    Science.gov (United States)

    Daneshian, Mardas; Wendel, Albrecht; Hartung, Thomas; von Aulock, Sonja

    2008-07-20

    The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. In this study we adapted the IPT to the testing of dialysis solutions. Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.

  7. Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction.

    Science.gov (United States)

    Yuan, Chao; Kosewick, Justin; He, Xiang; Kozak, Marta; Wang, Sihe

    2011-05-15

    Vitamin D plays important roles in bone health and a variety of other pathophysiological conditions. 1α,25-Dihydroxyvitamin D is the active form of vitamin D. Quantification of serum 1α,25-dihydroxyvitamin D is useful for evaluation of several diseases including chronic renal failure, hypoparathyroidism, sarcoidosis, and rickets. Measurement of 1α,25-dihydroxyvitamin D is very challenging due to its low circulating concentration and presence of interfering substances in serum. In this report, a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for quantifying serum 1α,25-dihydroxyvitamin D is described. Lithium adducts of 1α,25-dihydroxyvitamin D were formed prior to mass spectrometry analysis to improve ionization efficiency. We tested a number of different sample preparation procedures and found that immunoaffinity extraction was the method of choice because it completely removed isobaric interferences and matrix effects present in patient serum. Extraction efficiency, expressed as absolute recovery, was greater than 60% in both patient serum and charcoal-stripped serum. This method was linear from 3.4 to 206.2 pg/mL for 1α,25-dihydroxyvitamin D(3) and 3.9 to 212.6 pg/mL for 1α,25-dihydroxyvitamin D(2) with an accuracy of 89.8-98.4% and 97.5-115.7%, respectively. Inter-assay and intra-assay coefficients of variance (CVs) for both analytes at two different concentration levels ranged from 2.5-7.0%. Comparison with a radioimmunoassay for measuring total 1α,25-dihydroxyvitamin D concentration using 40 patient samples showed a Deming regression slope of 0.751, a y-intercept of 0.84 pg/mL, an r value of 0.7909, and a mean percentage difference of -27.1%. Comparison with a reference LC/MS/MS method (n = 20) showed a Deming regression slope of 1.020, a y-intercept of 1.32 pg/mL, an r value of 0.9797, and a mean percentage difference of -2.9%. In conclusion, usage of immunoaffinity extraction enabled a sensitive LC/MS/MS method for

  8. Highly sensitive and selective determination of methylergometrine maleate using carbon nanofibers/silver nanoparticles composite modified carbon paste electrode.

    Science.gov (United States)

    Kalambate, Pramod K; Rawool, Chaitali R; Karna, Shashi P; Srivastava, Ashwini K

    2016-12-01

    A highly sensitive and selective voltammetric method for determination of Methylergometrine maleate (MM) in pharmaceutical formulations, urine and blood serum samples has been developed based on enhanced electrochemical response of MM at carbon nanofibers and silver nanoparticles modified carbon paste electrode (CNF-AgNP-CPE). The electrode material was characterized by various techniques viz., X-ray diffraction, scanning electron microscopy and energy dispersive X-ray spectroscopy. The electrocatalytic response of MM at CNF-AgNP-CPE was studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the proposed sensor exhibits excellent electrochemical response towards MM. The DPV study shows greatly enhanced electrochemical signal for MM at CNF-AgNP-CPE lending high sensitivity to the proposed sensor for MM detection. The peak (Ip) current for MM is found to be rectilinear in the range 4.0×10(-8)-2.0×10(-5)M with a detection limit of 7.1×10(-9)M using DPV. The feasibility of the proposed sensor in analytical applications was investigated by conducting experiments on commercial pharmaceutical formulations, human urine and blood serum samples, which yielded satisfactory recoveries of MM. The proposed electrochemical sensor offers high sensitivity, selectivity, reproducibility and practical utility. We recommend it as an authentic and productive electrochemical sensor for successful determination of MM. Copyright © 2016. Published by Elsevier B.V.

  9. Assessing the Association between Serum Ferritin, Transferrin Saturation, and C-Reactive Protein in Northern Territory Indigenous Australian Patients with High Serum Ferritin on Maintenance Haemodialysis

    Directory of Open Access Journals (Sweden)

    Sandawana William Majoni

    2017-01-01

    Full Text Available Objective. To determine the significance of high serum ferritin observed in Indigenous Australian patients on maintenance haemodialysis in the Northern Territory, we assessed the relationship between ferritin and transferrin saturation (TSAT as measures of iron status and ferritin and C-reactive protein (CRP as markers of inflammation. Methods. We performed a retrospective cohort analysis of data from adult patients (≥18 years on maintenance haemodialysis (>3 months from 2004 to 2011. Results. There were 1568 patients. The mean age was 53.9 (11.9 years. 1244 (79.3% were Indigenous. 44.2% (n=693 were male. Indigenous patients were younger (mean age [52.3 (11.1 versus 57.4 (15.2, p<0.001] and had higher CRP [14.7 mg/l (7–35 versus 5.9 mg/l (1.9–17.5, p<0.001], higher median serum ferritin [1069 µg/l (668–1522 versus 794.9 µg/l (558.5–1252.0, p<0.001], but similar transferrin saturation [26% (19–37 versus 28% (20–38, p=0.516]. We observed a small positive correlation between ferritin and TSAT (r2=0.11, p<0.001, no correlation between ferritin and CRP (r2 = 0.001, p<0.001, and positive association between high serum ferritin and TSAT (p<0.001, Indigenous ethnicity (p<0.001, urea reduction ratio (p=0.001, and gender (p<0.001 after adjustment in mixed regression analysis. Conclusion. Serum ferritin and TSAT may inadequately reflect iron status in this population. The high ferritin was poorly explained by inflammation.

  10. Effect of chromium chloride supplementation on glucose tolerance and serum lipids including high-density lipoprotein of adult men.

    Science.gov (United States)

    Riales, R; Albrink, M J

    1981-12-01

    Chromium deficiency may cause insulin resistance, hyperinsulinemia, impaired glucose tolerance, and hyperlipidemia, recovered by chromium supplementation. The effect of chromium supplementation on serum lipids and glucose tolerance was tested in a double-blind 12-wk study of 23 healthy adult men aged 31 to 60 yr. Either 200 micrograms trivalent chromium in 5 ml water (Cr) or 5 ml plain water (W) was ingested daily 5 days each week. Half the subjects volunteered for glucose tolerance tests with insulin levels. At 12 wk high-density lipoprotein cholesterol increased in the Cr group from 35 to 39 mg/dl (p less than 0.05) but did not change in the water group (34 mg/dl). The largest increase in high-density lipoprotein cholesterol and decreases in insulin and glucose were found in those subjects having normal glucose levels together with elevated insulin levels at base-line. The data are thus consistent with the hypothesis that Cr supplementation raises high-density lipoprotein cholesterol and improves insulin sensitivity in those with evidence of insulin resistance but normal glucose tolerance.

  11. Luminescent Lanthanide Reporters for High-Sensitivity Novel Bioassays

    Energy Technology Data Exchange (ETDEWEB)

    Anstey, Mitchell R. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Fruetel, Julia A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Foster, Michael E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Hayden, Carl C. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Buckley, Heather L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Arnold, John [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2013-09-01

    Biological imaging and assay technologies rely on fluorescent organic dyes as reporters for a number of interesting targets and processes. However, limitations of organic dyes such as small Stokes shifts, spectral overlap of emission signals with native biological fluorescence background, and photobleaching have all inhibited the development of highly sensitive assays. To overcome the limitations of organic dyes for bioassays, we propose to develop lanthanide-based luminescent dyes and demonstrate them for molecular reporting applications. This relatively new family of dyes was selected for their attractive spectral and chemical properties. Luminescence is imparted by the lanthanide atom and allows for relatively simple chemical structures that can be tailored to the application. The photophysical properties offer unique features such as narrow and non-overlapping emission bands, long luminescent lifetimes, and long wavelength emission, which enable significant sensitivity improvements over organic dyes through spectral and temporal gating of the luminescent signal.Growth in this field has been hindered due to the necessary advanced synthetic chemistry techniques and access to experts in biological assay development. Our strategy for the development of a new lanthanide-based fluorescent reporter system is based on chelation of the lanthanide metal center using absorbing chromophores. Our first strategy involves "Click" chemistry to develop 3-fold symmetric chelators and the other involves use of a new class of tetrapyrrole ligands called corroles. This two-pronged approach is geared towards the optimization of chromophores to enhance light output.

  12. New application of superconductors: High sensitivity cryogenic light detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cardani, L., E-mail: laura.cardani@roma1.infn.it [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); Physics Department, Princeton University, Washington Road, 08544 Princeton, NJ (United States); Bellini, F.; Casali, N. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); Castellano, M.G. [Istituto di Fotonica e Nanotecnologie – CNR, Via Cineto Romano 42, 00156 Roma (Italy); Colantoni, I.; Coppolecchia, A. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); Cosmelli, C.; Cruciani, A. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); D' Addabbo, A. [INFN – Laboratori Nazionali del Gran Sasso, Assergi (L' Aquila) 67010 (Italy); Di Domizio, S. [INFN – Sezione di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Dipartimento di Fisica, Università degli Studi di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Martinez, M. [Dipartimento di Fisica, Sapienza Università di Roma, Piazzale Aldo Moro 2, 00185 Roma (Italy); INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); Laboratorio de Fisica Nuclear y Astroparticulas, Universidad de Zaragoza, Zaragoza 50009 (Spain); Tomei, C. [INFN – Sezione di Roma, Piazzale Aldo Moro 2, 00185 Roma, Italy (Italy); and others

    2017-02-11

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs) that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2×2 cm{sup 2} substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.

  13. New application of superconductors: High sensitivity cryogenic light detectors

    International Nuclear Information System (INIS)

    Cardani, L.; Bellini, F.; Casali, N.; Castellano, M.G.; Colantoni, I.; Coppolecchia, A.; Cosmelli, C.; Cruciani, A.; D'Addabbo, A.; Di Domizio, S.; Martinez, M.; Tomei, C.

    2017-01-01

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs) that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2×2 cm"2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.

  14. Sensitivity of CA 15-3, CEA and serum HER2 in the early detection of recurrence of breast cancer

    DEFF Research Database (Denmark)

    Eriksen, Ann Christina; Sørensen, Patricia Diana; Jacobsen, Erik Hugger

    2013-01-01

    The aim of this project was to investigate the sensitivity of CA 15-3, CEA and HER2 in the early diagnosis of metastatic breast cancer.......The aim of this project was to investigate the sensitivity of CA 15-3, CEA and HER2 in the early diagnosis of metastatic breast cancer....

  15. Adult Kawasaki's disease with myocarditis, splenomegaly, and highly elevated serum ferritin levels.

    Science.gov (United States)

    Cunha, Burke A; Pherez, Francisco M; Alexiadis, Varvara; Gagos, Marios; Strollo, Stephanie

    2010-01-01

    erythema. We present a case of adult Kawasaki's disease with myocarditis and splenomegaly. The patient's myocarditis rapidly resolved, and he did not develop coronary artery aneurysms. In addition to splenomegaly, this case of adult Kawasaki's disease is remarkable because the patient had highly elevated serum ferritin levels of 944-1303 ng/mL; (normalfever for> or =5 days with conjunctival suffusion, cervical adenopathy, swelling of the dorsum of the hands/feet, thrombocytosis and otherwise unexplained highly elevated ferritin levels. Copyright 2010 Elsevier Inc. All rights reserved.

  16. The Differences in Serum Quantitative Specific IgE Levels Induced by Dermatophagoides pteronyssinus, Dermatophagoides farinae and Blomia tropicalis Sensitization in Intermittent and Persistent Allergic Asthma

    Directory of Open Access Journals (Sweden)

    Agus Joko Susanto

    2018-01-01

    Full Text Available Background: house dust mites (HDM are an important inhalant allergen in allergic asthma. However, molecular diagnostic study of specific IgE to HDM allergens has not been done in Indonesia. In addition, the association of quantitative specific IgE measurement with asthma severity has not been investigatedd. This study aimed to investigate the difference of serum quantitative specific IgE levels induced by Dermatophagoides (D. pteronyssinus, D. farinae and Blomia tropicalis sensitization in intermittent and persistent allergic asthma. Methods: this was a cross-sectional study on adult allergic asthma patients who were invited for serum specific IgE testing. This study was a part of a larger study within the Division of Allergy and Immunology, Cipto Mangunkusumo Hospital. Asthma severity was defined based on Global Initiative on Asthma (GINA 2015 criteria and were grouped as intermittent or persistent. Quantitative specific IgE testing was done on blood serum using a multiple allergosorbent test (Polycheck Allergy, Biocheck GmbH, Munster, Germany. The HDM allergens tested were D. pteronyssinus, D. farinae, and Blomia tropicalis. Difference between two groups were analyze using Mann-Whitney test. Results: a total of 87 subjects were enrolled in this study; 69 (79.3% were women. Mean patients’ age was 40, 2 years. Sixty-three (72.4% subjects had asthma and allergic rhinitis. Fifty-eight (66.7% subjects were classified as persistent asthma. The prevalence of sensitization was 62.1% for D. farinae, 51.7% for D. pteronyssinus, and 48.3% for Blomia tropicalis. The median of specific IgE levels were significantly higher in persistent asthma compares to intermittent asthma induced by D. farinae (median 1.30 vs. 0.0 kU/L; p=0.024 and B. tropicalis (median 0.57 vs. 0.0 kU/L; p=0.015 sensitization. Level of Specific IgE  D. pteronyssinus was also to be higher in persistent asthma than the level measured in intermittent asthma (0.67 vs. 0.00 kU/L; p=0

  17. Highly sensitive and selective determination of methylergometrine maleate using carbon nanofibers/silver nanoparticles composite modified carbon paste electrode

    International Nuclear Information System (INIS)

    Kalambate, Pramod K.; Rawool, Chaitali R.; Karna, Shashi P.; Srivastava, Ashwini K.

    2016-01-01

    A highly sensitive and selective voltammetric method for determination of Methylergometrine maleate (MM) in pharmaceutical formulations, urine and blood serum samples has been developed based on enhanced electrochemical response of MM at carbon nanofibers and silver nanoparticles modified carbon paste electrode (CNF-AgNP-CPE). The electrode material was characterized by various techniques viz., X-ray diffraction, scanning electron microscopy and energy dispersive X-ray spectroscopy. The electrocatalytic response of MM at CNF-AgNP-CPE was studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Under optimized conditions, the proposed sensor exhibits excellent electrochemical response towards MM. The DPV study shows greatly enhanced electrochemical signal for MM at CNF-AgNP-CPE lending high sensitivity to the proposed sensor for MM detection. The peak (I p ) current for MM is found to be rectilinear in the range 4.0 × 10 −8 –2.0 × 10 −5 M with a detection limit of 7.1 × 10 −9 M using DPV. The feasibility of the proposed sensor in analytical applications was investigated by conducting experiments on commercial pharmaceutical formulations, human urine and blood serum samples, which yielded satisfactory recoveries of MM. The proposed electrochemical sensor offers high sensitivity, selectivity, reproducibility and practical utility. We recommend it as an authentic and productive electrochemical sensor for successful determination of MM. - Highlights: • Voltammetric sensor for methylergometrine maleate using carbon nanofibers and silver nanoparticle - carbon paste electrode • Wide working range, good reproducibility, fast response and high stability were the main advantages of the proposed sensor • Analysis of methylergometrine maleate in pharmaceutical formulations, urine and blood serum samples • Lowest limit of detection obtained for methylergometrine maleate

  18. Sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction detecting feline coronavirus mutations in effusion and serum/plasma of cats to diagnose feline infectious peritonitis.

    Science.gov (United States)

    Felten, Sandra; Leutenegger, Christian M; Balzer, Hans-Joerg; Pantchev, Nikola; Matiasek, Kaspar; Wess, Gerhard; Egberink, Herman; Hartmann, Katrin

    2017-08-02

    Feline coronavirus (FCoV) exists as two pathotypes, and FCoV spike gene mutations are considered responsible for the pathotypic switch in feline infectious peritonitis (FIP) pathogenesis. The aim of this study was to evaluate sensitivity and specificity of a real-time reverse transcriptase polymerase chain reaction (RT-PCR) specifically designed to detect FCoV spike gene mutations at two nucleotide positions. It was hypothesized that this test would correctly discriminate feline infectious peritonitis virus (FIPV) and feline enteric coronavirus (FECV). The study included 63 cats with signs consistent with FIP. FIP was confirmed in 38 cats. Twenty-five control cats were definitively diagnosed with a disease other than FIP. Effusion and/or serum/plasma samples were examined by real-time RT-PCR targeting the two FCoV spike gene fusion peptide mutations M1058 L and S1060A using an allelic discrimination approach. Sensitivity, specificity, negative and positive predictive values including 95% confidence intervals (95% CI) were calculated. FIPV was detected in the effusion of 25/59 cats, one of them being a control cat with chronic kidney disease. A mixed population of FIPV/FECV was detected in the effusion of 2/59 cats; all of them had FIP. RT-PCR was negative or the pathotype could not be determined in 34/59 effusion samples. In effusion, sensitivity was 68.6% (95% CI 50.7-83.2), specificity was 95.8% (95% CI 78.9-99.9). No serum/plasma samples were positive for FIPV. Although specificity of the test in effusions was high, one false positive result occurred. The use of serum/plasma cannot be recommended due to a low viral load in blood.

  19. High-Sensitivity AGN Polarimetry at Sub-Millimeter Wavelengths

    Directory of Open Access Journals (Sweden)

    Ivan Martí-Vidal

    2017-10-01

    Full Text Available The innermost regions of radio loud Active Galactic Nuclei (AGN jets are heavily affected by synchrotron self-absorption, due to the strong magnetic fields and high particle densities in these extreme zones. The only way to overcome this absorption is to observe at sub-millimeter wavelengths, although polarimetric observations at such frequencies have so far been limited by sensitivity and calibration accuracy. However, new generation instruments such as the Atacama Large mm/sub-mm Array (ALMA overcome these limitations and are starting to deliver revolutionary results in the observational studies of AGN polarimetry. Here we present an overview of our state-of-the-art interferometric mm/sub-mm polarization observations of AGN jets with ALMA (in particular, the gravitationally-lensed sources PKS 1830−211 and B0218+359, which allow us to probe the magneto-ionic conditions at the regions closest to the central black holes.

  20. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  1. High resolution, position sensitive detector for energetic particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, E P [Charles Evans and Associates, Redwood City, CA (United States); Strathman, M D [Charles Evans and Associates, Redwood City, CA (United States); Reed, D A [Charles Evans and Associates, Redwood City, CA (United States); Odom, R W [Charles Evans and Associates, Redwood City, CA (United States); Morse, D H [Sandia National Labs., Livermore, CA (United States); Pontau, A E [Sandia National Labs., Livermore, CA (United States)

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10[sup 10]), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 [mu]m for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 [mu]m) with an image resolution of better than 0.5 [mu]m has since been developed and its design is presented. (orig.)

  2. Highly Sensitive Filter Paper Substrate for SERS Trace Explosives Detection

    Directory of Open Access Journals (Sweden)

    Pedro M. Fierro-Mercado

    2012-01-01

    Full Text Available We report on a novel and extremely low-cost surface-enhanced Raman spectroscopy (SERS substrate fabricated depositing gold nanoparticles on common lab filter paper using thermal inkjet technology. The paper-based substrate combines all advantages of other plasmonic structures fabricated by more elaborate techniques with the dynamic flexibility given by the inherent nature of the paper for an efficient sample collection, robustness, and stability. We describe the fabrication, characterization, and SERS activity of our substrate using 2,4,6-trinitrotoluene, 2,4-dinitrotoluene, and 1,3,5-trinitrobenzene as analytes. The paper-based SERS substrates presented a high sensitivity and excellent reproducibility for analytes employed, demonstrating a direct application in forensic science and homeland security.

  3. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui

    2010-06-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  4. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui; Liu, Jingyuan; Cevey-Ha, Ngoc-Le; Moon, Soo-Jin; Liska, Paul; Humphry-Baker, Robin; Moser, Jacques-E.; Grä tzel, Carole; Wang, Peng; Zakeeruddin, Shaik M.

    2010-01-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  5. POTENTIALITIES OF DIAGNOSTICS AND DIFFERENTIAL DIAGNOSTICS OF STOMACH DISEASES BY MEANS OF USAGE OF HIGH-PERFORMANCE BLOOD SERUM LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    O.P. Alexeeva

    2008-12-01

    Full Text Available 62 patients with the endoscopically and morphologicallyverified diagnosis of the chronic gastritis, 89 patients with the morphologically verified diagnosis of stomach cancer and 43 healthy persons ages 23 to 54 years have been examined. Potentialities of the usage of high-performance blood serum liquid chromatography have been studied for the purpose of diagnostics and differential diagnostics of chronic gastritis and stomach cancer. Blood serum driedextract was investigated by means of"Milichrome A02"chromatograph (Novosibirsk, "Econova" joint-stock company. The chromatograms were treated by the multivahate cluster analysis with the formation of pathologic three-dimensional characteristic state notably differed from the healthy human image. Diagnostic sensitivity of chronic gastritis and stomach cancer acounts for accordingly 92% and 96%. Diagnostic accuracy of the method comes to 94%.

  6. High-sensitivity cardiac troponin I assay to screen for acute rejection in patients with heart transplant.

    Science.gov (United States)

    Patel, Parag C; Hill, Douglas A; Ayers, Colby R; Lavingia, Bhavna; Kaiser, Patricia; Dyer, Adrian K; Barnes, Aliessa P; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Stastny, Peter; Ring, W Steves; de Lemos, James A; Drazner, Mark H

    2014-05-01

    A noninvasive biomarker that could accurately diagnose acute rejection (AR) in heart transplant recipients could obviate the need for surveillance endomyocardial biopsies. We assessed the performance metrics of a novel high-sensitivity cardiac troponin I (cTnI) assay for this purpose. Stored serum samples were retrospectively matched to endomyocardial biopsies in 98 cardiac transplant recipients, who survived ≥3 months after transplant. AR was defined as International Society for Heart and Lung Transplantation grade 2R or higher cellular rejection, acellular rejection, or allograft dysfunction of uncertain pathogenesis, leading to treatment for presumed rejection. cTnI was measured with a high-sensitivity assay (Abbott Diagnostics, Abbott Park, IL). Cross-sectional analyses determined the association of cTnI concentrations with rejection and International Society for Heart and Lung Transplantation grade and the performance metrics of cTnI for the detection of AR. Among 98 subjects, 37% had ≥1 rejection episode. cTnI was measured in 418 serum samples, including 35 paired to a rejection episode. cTnI concentrations were significantly higher in rejection versus nonrejection samples (median, 57.1 versus 10.2 ng/L; P<0.0001) and increased in a graded manner with higher biopsy scores (P(trend)<0.0001). The c-statistic to discriminate AR was 0.82 (95% confidence interval, 0.76-0.88). Using a cut point of 15 ng/L, sensitivity was 94%, specificity 60%, positive predictive value 18%, and negative predictive value 99%. A high-sensitivity cTnI assay seems useful to rule out AR in cardiac transplant recipients. If validated in prospective studies, a strategy of serial monitoring with a high-sensitivity cTnI assay may offer a low-cost noninvasive strategy for rejection surveillance. © 2014 American Heart Association, Inc.

  7. Effective dose calculation in CT using high sensitivity TLDs

    International Nuclear Information System (INIS)

    Brady, Z.; Johnston, P.N.

    2010-01-01

    Full text: To determine the effective dose for common paediatric CT examinations using thermoluminescence dosimetry (TLD) mea surements. High sensitivity TLD chips (LiF:Mg,Cu,P, TLD-IOOH, Thermo Fisher Scientific, Waltham, MA) were calibrated on a linac at an energy of 6 MY. A calibration was also performed on a superricial X-ray unit at a kilovoltage energy to validate the megavoltage cali bration for the purpose of measuring doses in the diagnostic energy range. The dose variation across large organs was assessed and a methodology for TLD placement in a 10 year old anthropomorphic phantom developed. Effective dose was calculated from the TLD measured absorbed doses for typical CT examinations after correcting for the TLD energy response and taking into account differences in the mass energy absorption coefficients for different tissues and organs. Results Using new tissue weighting factors recommended in ICRP Publication 103, the effective dose for a CT brain examination on a 10 year old was 1.6 millisieverts (mSv), 4.9 mSv for a CT chest exa ination and 4.7 mSv for a CT abdomen/pelvis examination. These values are lower for the CT brain examination, higher for the CT chest examination and approximately the same for the CT abdomen/ pelvis examination when compared with effective doses calculated using ICRP Publication 60 tissue weighting factors. Conclusions High sensitivity TLDs calibrated with a radiotherapy linac are useful for measuring dose in the diagnostic energy range and overcome limitations of output reproducibility and uniformity asso ciated with traditional TLD calibration on CT scanners or beam quality matched diagnostic X-ray units.

  8. High serum YKL-40 level in a cohort of octogenarians is associated with increased risk of all-cause mortality

    DEFF Research Database (Denmark)

    Johansen, J. S.; Pedersen, Agnes Nadelmann; Schroll, M.

    2007-01-01

    YKL-40 is secreted by macrophages, neutrophils, chondrocytes, endothelial-, vascular smooth muscle- and cancer cells. Interleukin (IL)-6 stimulates YKL-40 production in human in vivo studies. High serum YKL-40 is associated with poor prognosis in patients with inflammatory diseases and cancer. We...... studied whether serum YKL-40 was associated with systemic low-level inflammation, an immune risk phenotype, and mortality in relatively healthy 80-year old humans. Serum YKL-40, IL-6 and tumour necrosis factor (TNF)-alpha were measured by enzyme-linked immunosorbent assays (ELISAs) in octogenarians (n...

  9. Effect of Probiotic Lactobacillus salivarius UBL S22 and Prebiotic Fructo-oligosaccharide on Serum Lipids, Inflammatory Markers, Insulin Sensitivity, and Gut Bacteria in Healthy Young Volunteers: A Randomized Controlled Single-Blind Pilot Study.

    Science.gov (United States)

    Rajkumar, Hemalatha; Kumar, Manoj; Das, Nilita; Kumar, S Nishanth; Challa, Hanumanth R; Nagpal, Ravinder

    2015-05-01

    This study investigated the effect of 6-week supplementation of a probiotic strain Lactobacillus salivarius UBL S22 with or without prebiotic fructo-oligosaccharide (FOS) on serum lipid profiles, immune responses, insulin sensitivity, and gut lactobacilli in 45 healthy young individuals. The patients were divided into 3 groups (15/group), that is, placebo, probiotic, and synbiotic. After 6 weeks, a significant reduction (P < .05) in total cholesterol, low-density lipoprotein (LDL) cholesterol, and triglycerides and increase in high-density lipoprotein cholesterol was observed in the probiotic as well as in the synbiotic group when compared to placebo; however, the results of total cholesterol and LDL-cholesterol were more pronounced in the synbiotic group. Similarly, when compared to the placebo group, the serum concentrations of inflammatory markers such as high sensitivity C-reactive protein, interleukin (IL) 6, IL-1β, and tumor necrosis factor α were significantly (P < .05) reduced in both the experimental groups, but again the reduction in the synbiotic group was more pronounced. Also, an increase (P < .05) in the fecal counts of total lactobacilli and a decrease (P < .05) in coliforms and Escherichia coli was observed in both the experimental groups after 6 weeks of ingestion. Overall, the combination of L salivarius with FOS was observed to be more beneficial than L salivarius alone, thereby advocating that such synbiotic combinations could be therapeutically exploited for improved health and quality of life. © The Author(s) 2014.

  10. Scanning Auger microscopy for high lateral and depth elemental sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, E., E-mail: eugenie.martinez@cea.fr [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Yadav, P. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Bouttemy, M. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Renault, O.; Borowik, Ł.; Bertin, F. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Etcheberry, A. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Chabli, A. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France)

    2013-12-15

    Highlights: •SAM performances and limitations are illustrated on real practical cases such as the analysis of nanowires and nanodots. •High spatial elemental resolution is shown with the analysis of reference semiconducting Al{sub 0.7}Ga{sub 0.3}As/GaAs multilayers. •High in-depth elemental resolution is also illustrated. Auger depth profiling with low energy ion beams allows revealing ultra-thin layers (∼1 nm). •Analysis of cross-sectional samples is another effective approach to obtain in-depth elemental information. -- Abstract: Scanning Auger microscopy is currently gaining interest for investigating nanostructures or thin multilayers stacks developed for nanotechnologies. New generation Auger nanoprobes combine high lateral (∼10 nm), energy (0.1%) and depth (∼2 nm) resolutions thus offering the possibility to analyze the elemental composition as well as the chemical state, at the nanometre scale. We report here on the performances and limitations on practical examples from nanotechnology research. The spatial elemental sensitivity is illustrated with the analysis of Al{sub 0.7}Ga{sub 0.3}As/GaAs heterostructures, Si nanowires and SiC nanodots. Regarding the elemental in-depth composition, two effective approaches are presented: low energy depth profiling to reveal ultra-thin layers (∼1 nm) and analysis of cross-sectional samples.

  11. Highly sensitive detection of molecular interactions with plasmonic optical fiber grating sensors.

    Science.gov (United States)

    Voisin, Valérie; Pilate, Julie; Damman, Pascal; Mégret, Patrice; Caucheteur, Christophe

    2014-01-15

    Surface Plasmon resonance (SPR) optical fiber biosensors constitute a miniaturized counterpart to the bulky prism configuration and offer remote operation in very small volumes of analyte. They are a cost-effective and relatively straightforward technique to yield in situ (or even possibly in vivo) molecular detection. The biosensor configuration reported in this work uses nanometric-scale gold-coated tilted fiber Bragg gratings (TFBGs) interrogated by light polarized radially to the optical fiber outer surface, so as to maximize the optical coupling with the SPR. These gratings were recently associated to aptamers to assess their label-free biorecognition capability in buffer and serum solutions. In this work, using the well-acknowledged biotin-streptavidin pair as a benchmark, we go forward in the demonstration of their unique sensitivity. In addition to the monitoring of the self-assembled monolayer (SAM) in real time, we report an unprecedented limit of detection (LOD) as low as 2 pM. Finally, an immunosensing experiment is realized with human transferrin (dissociation constant Kd~10(-8) M(-1)). It allows to assess both the reversibility and the robustness of the SPR-TFBG biosensors and to confirm their high sensitivity. © 2013 Published by Elsevier B.V.

  12. Fabrication of CuO nanoplatelets for highly sensitive enzyme-free determination of glucose

    Energy Technology Data Exchange (ETDEWEB)

    Wang Juan [School of Chemistry and Chemical Engineering, South China University of Technology, 381 Wushan Road, Guangzhou 510640 (China); Zhang Weide, E-mail: zhangwd@scut.edu.cn [School of Chemistry and Chemical Engineering, South China University of Technology, 381 Wushan Road, Guangzhou 510640 (China)

    2011-09-01

    Highlights: > Adhered growth of CuO nanoplatelets on Cu foils. > Enzyme-free glucose sensor with very high sensitivity. > Excellent stability and good anti-interference ability. - Abstract: CuO nanoplatelets were grown on Cu foils by a one step, template free process. The structure and morphology of the CuO nanoplatelets were characterized by X-ray diffraction, scanning and transmission electron microscopy. The CuO nanoplatelets grown on Cu foil were integrated to be an electrode for glucose sensing. The electrocatalytic activity of the CuO nanoplatelets electrode for glucose in alkaline media was investigated by cyclic voltammetry and chronoamperometry. The electrode exhibits a sensitivity of 3490.7 {mu}A mM{sup -1} cm{sup -2} to glucose which is much higher than that of most reported enzyme-free glucose sensors and the linear range was obtained over a concentration up to 0.80 mM with a detection limit of 0.50 {mu}M (signal/noise = 3). Exhilaratingly, the electrode based on the CuO nanoplatelets is resistant against poisoning by chloride ion, and the interference from the oxidation of common interfering species, such as uric acid, ascorbic acid, dopamine and carbonhydrate compounds, can also be effectively avoided. Finally, the electrode was applied to analyze glucose concentration in human serum samples.

  13. High salt diet induces metabolic alterations in multiple biological processes of Dahl salt-sensitive rats.

    Science.gov (United States)

    Wang, Yanjun; Liu, Xiangyang; Zhang, Chen; Wang, Zhengjun

    2018-06-01

    High salt induced renal disease is a condition resulting from the interactions of genetic and dietary factors causing multiple complications. To understand the metabolic alterations associated with renal disease, we comprehensively analyzed the metabonomic changes induced by high salt intake in Dahl salt-sensitive (SS) rats using GC-MS technology and biochemical analyses. Physiological features, serum chemistry, and histopathological data were obtained as complementary information. Our results showed that high salt (HS) intake for 16 weeks caused significant metabolic alterations in both the renal medulla and cortex involving a variety pathways involved in the metabolism of organic acids, amino acids, fatty acids, and purines. In addition, HS enhanced glycolysis (hexokinase, phosphofructokinase and pyruvate kinase) and amino acid metabolism and suppressed the TCA (citrate synthase and aconitase) cycle. Finally, HS intake caused up-regulation of the pentose phosphate pathway (glucose 6-phosphate dehydrogenase and 6-phosphogluconate dehydrogenase), the ratio of NADPH/NADP + , NADPH oxidase activity and ROS production, suggesting that increased oxidative stress was associated with an altered PPP pathway. The metabolic pathways identified may serve as potential targets for the treatment of renal damage. Our findings provide comprehensive biochemical details about the metabolic responses to a high salt diet, which may contribute to the understanding of renal disease and salt-induced hypertension in SS rats. Copyright © 2018. Published by Elsevier Inc.

  14. Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.

    Science.gov (United States)

    Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo

    2018-02-23

    The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.

  15. Laser-engraved carbon nanotube paper for instilling high sensitivity, high stretchability, and high linearity in strain sensors

    KAUST Repository

    Xin, Yangyang

    2017-06-29

    There is an increasing demand for strain sensors with high sensitivity and high stretchability for new applications such as robotics or wearable electronics. However, for the available technologies, the sensitivity of the sensors varies widely. These sensors are also highly nonlinear, making reliable measurement challenging. Here we introduce a new family of sensors composed of a laser-engraved carbon nanotube paper embedded in an elastomer. A roll-to-roll pressing of these sensors activates a pre-defined fragmentation process, which results in a well-controlled, fragmented microstructure. Such sensors are reproducible and durable and can attain ultrahigh sensitivity and high stretchability (with a gauge factor of over 4.2 × 10(4) at 150% strain). Moreover, they can attain high linearity from 0% to 15% and from 22% to 150% strain. They are good candidates for stretchable electronic applications that require high sensitivity and linearity at large strains.

  16. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    Science.gov (United States)

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  17. Resting Serum Concentration of High-Sensitivity C-Reactive Protein ...

    African Journals Online (AJOL)

    olayemitoyin

    stress which may be more prevalent in sportsmen has also been shown to initiate an increase in ..... Sato, K. (1999) 'Endurance exercise causes interaction among stress hormones, cytokines, neutrophil dynamics, and muscle damage', J Appl ...

  18. A multiple antibiotic and serum resistant oligotrophic strain, Klebsiella pneumoniae MB45 having novel dfrA30, is sensitive to ZnO QDs

    Directory of Open Access Journals (Sweden)

    Chakrabarti Pinak

    2011-05-01

    Full Text Available Abstract Background The aim of this study was to describe a novel trimethoprim resistance gene cassette, designated dfrA30, within a class 1 integron in a facultatively oligotrophic, multiple antibiotic and human serum resistant test strain, MB45, in a population of oligotrophic bacteria isolated from the river Mahananda; and to test the efficiency of surface bound acetate on zinc oxide quantum dots (ZnO QDs as bactericidal agent on MB45. Methods Diluted Luria broth/Agar (10-3 media was used to cultivate the oligotrophic bacteria from water sample. Multiple antibiotic resistant bacteria were selected by employing replica plate method. A rapid assay was performed to determine the sensitivity/resistance of the test strain to human serum. Variable region of class 1 integron was cloned, sequenced and the expression of gene coding for antibiotic resistance was done in Escherichia coli JM 109. Identity of culture was determined by biochemical phenotyping and 16S rRNA gene sequence analyses. A phylogenetic tree was constructed based on representative trimethoprim resistance-mediating DfrA proteins retrieved from GenBank. Growth kinetic studies for the strain MB45 were performed in presence of varied concentrations of ZnO QDs. Results and conclusions The facultatively oligotrophic strain, MB45, resistant to human serum and ten antibiotics trimethoprim, cotrimoxazole, ampicillin, gentamycin, netilmicin, tobramycin, chloramphenicol, cefotaxime, kanamycin and streptomycin, has been identified as a new strain of Klebsiella pneumoniae. A novel dfr gene, designated as dfrA30, found integrated in class 1 integron was responsible for resistance to trimethoprim in Klebsiella pneumoniae strain MB45. The growth of wild strain MB45 was 100% arrested at 500 mg/L concentration of ZnO QDs. To our knowledge this is the first report on application of ZnO quantum dots to kill multiple antibiotics and serum resistant K. pneumoniae strain.

  19. Insulin sensitivity and serum TCDD in Air Force veterans occupationally exposed to herbicides during the Vietnam war

    Energy Technology Data Exchange (ETDEWEB)

    Kern, P.; Said, S. [Univ. of Arkansas for Medical Sciences, Little Rock (United States); Jackson, W. Jr; Michalek, J. [Air Force Research Lab., San Antonio (United States)

    2004-09-15

    Between 1961 and 1971, the United States Air Force sprayed 12 million gallons of the defoliant ''Agent Orange'' on 3.6 million acres of Vietnam. Agent Orange was a 1:1 mixture of 2,4-dichlorophenoxyacetic acid and 2,4,5- trichlorophenoxyacetic acid, and 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) was a contaminant of the defoliant, from less than 0.05 to almost 50 parts per million. Numerous Vietnam veterans were exposed to TCDD when Agent Orange and other TCDD-contaminated herbicides were sprayed in large quantities in Vietnam and TCDD has been found at many toxic waste disposal sites in the United States. Some of the highest exposure to TCDD occurred in members of Operation Ranch Hand, the Air Force unit responsible for spraying herbicides from fix-wing aircraft in Vietnam. The Air Force Health Study (AFHS), an epidemiological study of Ranch Hand veterans, was launched in 1980 to address veteran concerns regarding Agent Orange exposure. A link between TCDD and diabetes has been demonstrated in several studies. Among the Ranch Hand veterans with high blood levels of TCDD, there was a significant increase in the prevalence of diabetes and a decrease in the age at which diabetes was diagnosed. In a study from Seveso, Italy, where 45,000 people had varying levels of exposure to TCDD, there were significant increases in mortality from coronary artery disease and diabetes. Several studies have demonstrated a relationship between blood TCDD levels and hyperinsulinemia. The data suggest that non-diabetic individuals exposed to TCDD have an increased risk of insulin-resistance, being able to maintain normal blood glucose levels but only because of very high concentrations of insulin. As a result of available evidence, public policy decisions have been made, such as a decision by the Veterans Administration that diabetes is a service-connected condition in Agent Orange-exposed Vietnam veterans. Here we study the relation between TCDD insulin sensitivity

  20. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Science.gov (United States)

    Arampatzis, Georgios; Katsoulakis, Markos A; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the

  1. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Directory of Open Access Journals (Sweden)

    Georgios Arampatzis

    Full Text Available Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of

  2. Simple and sensitive method for the quantification of total bilirubin in human serum using 3-methyl-2-benzothiazolinone hydrazone hydrochloride as a chromogenic probe

    Science.gov (United States)

    Nagaraja, Padmarajaiah; Avinash, Krishnegowda; Shivakumar, Anantharaman; Dinesh, Rangappa; Shrestha, Ashwinee Kumar

    2010-11-01

    We here describe a new spectrophotometric method for measuring total bilirubin in serum. The method is based on the cleavage of bilirubin giving formaldehyde which further reacts with diazotized 3-methyl-2-benzothiazolinone hydrazone hydrochloride giving blue colored solution with maximum absorbance at 630 nm. Sensitivity of the developed method was compared with Jendrassik-Grof assay procedure and its applicability has been tested with human serum samples. Good correlation was attained between both methods giving slope of 0.994, intercept 0.015, and R2 = 0.997. Beers law obeyed in the range of 0.068-17.2 μM with good linearity, absorbance y = 0.044 Cbil + 0.003. Relative standard deviation was 0.006872, within day precision ranged 0.3-1.2% and day-to-day precision ranged 1-6%. Recovery of the method varied from 97 to 102%. The proposed method has higher sensitivity with less interference. The obtained product was extracted and was spectrally characterized for structural confirmation with FT-IR, 1H NMR.

  3. Association of high-sensitivity C-reactive protein and uric acid with the metabolic syndrome components.

    Science.gov (United States)

    Sah, Santosh Kumar; Khatiwada, Saroj; Pandey, Sunil; Kc, Rajendra; Das, Binod Kumar Lal; Baral, Nirmal; Lamsal, Madhab

    2016-01-01

    Metabolic syndrome (MetS) has been found to be associated with inflammatory molecules. This study was conducted among 125 MetS patients at B P Koirala Institute of Health Sciences, Dharan, Nepal to find an association of high-sensitivity C-reactive protein (hs-CRP) and serum uric acid with MetS components. Anthropometric measurements, blood pressure, medical history and blood samples were taken. Estimation of hs-CRP, serum uric acid, blood glucose, triglyceride and high density lipoprotein (HDL) cholesterol was done. hs-CRP had positive correlation with blood glucose (r = 0.2, p = 0.026) and negative with HDL cholesterol (r = -0.361, p high uric acid were individually associated with higher odds for low HDL cholesterol (7.992; 1.785-35.774, p = 0.002) and hyperglycemia (2.471; 1.111-5.495, p = 0.029) respectively. Combined rise of hs-CRP and uric acid was associated with severity of MetS (p rise of hs-CRP or uric acid. The present study demonstrates that hs-CRP and serum uric acid are associated with MetS components, and the combined rise of hs-CRP and uric acid is associated with the increase in severity of MetS.

  4. Radioimmunoassay (RIA), a highly specific, extremely sensitive quantitative method of analysis

    Energy Technology Data Exchange (ETDEWEB)

    Strecker, H; Hachmann, H; Seidel, L [Farbwerke Hoechst A.G., Frankfurt am Main (Germany, F.R.). Radiochemisches Lab.

    1979-02-01

    Radioimmunoassay is an analytical method combining the sensitivity of radioactivity measurements and the specificity of the antigen-antibody-reaction. Thus, substances can be measured in concentrations as low as picograms per milliliter serum besides a millionfold excess of otherwise disturbing material (for example in serum). The method is simple to perform and is at present mainly used in the field of endocrinology. Further areas of possible application are in the diagnosis of infectious disease, drug research, environmental protection, forensic medicine as well as general analytics. Quantities of radioactivity, exclusively used in vitro, are in the nano-Curie range. Therefore the radiation dose is negligible.

  5. High Level of Soluble FMS-Like Tyrosine Kinase-1 (sFlt-1 Serum in Pregnancy as a Risk Factor of Preeclampsia

    Directory of Open Access Journals (Sweden)

    I Gede Mega Putra

    2016-07-01

    Full Text Available Background: Recently, etiology and pathogenesis of preeclampsia remain unknown. One of the theory indicating that hypoxia and ischemic placenta caused by abnormal cytotrophoblast invasion in preeclampsia. Soluble Fms-like tyrosine kinase-1 (sFlt-1 serum as a laboratory marker of hypoxia condition that contributes to the occurrence of endothelial damage and clinical manifestations in preeclampsia. Objective: This study was aimed at proving that high level of soluble Fms-like tyrosine kinase-1 (sFlt-1 serum in pregnancy as a risk factor for preeclampsia. Methods: This study was a case control. Among 58 pregnant women studied, 29 women with preeclampsia as a case group and 29 women with normal pregnancy as a control group. Soluble Fms-like tyrosine kinase-1 (sFlt-1 serum was analyzed in the Prodia Laboratory. Collected data were tested for normality using Kolmogorov-Smirnov, then analyzed with independent sample test. Chi-Square test used to determine soluble Fms-like tyrosine kinase-1 (sFlt-1 serum level in preeclampsia. Results: This research concluded that the average level of soluble Fms-like tyrosine kinase-1 (sFlt-1 serum in preeclampsia were 11231.00 ± 8390.3 pg/mL and 3981.62 ± 4921.5 pg/mL in normal pregnancy. Analysis of significance with independent t-test concluded that the value of t = 4.01 and p = 0.001. This mean the average levels of soluble Fms-like tyrosine kinase-1 (sFlt-1serum levels in both groups were difference significantly (p <0.05. Based on the cut-off point of sFlt-1 serum levels was 4505.50 pg/mL with 79.3% sensitivity and 82.8% specificity, the relative risk of preeclampsia was 18 times (OR = 18.40, IK 95% = 4.93 to 68.70, p = 0.001. Conclusion:  Based on this research, high levels of soluble Fms-like tyrosine kinase-1 (sFlt-1 in pregnancy was proved as a risk factor for preeclampsia.

  6. Adjoint sensitivity analysis of high frequency structures with Matlab

    CERN Document Server

    Bakr, Mohamed; Demir, Veysel

    2017-01-01

    This book covers the theory of adjoint sensitivity analysis and uses the popular FDTD (finite-difference time-domain) method to show how wideband sensitivities can be efficiently estimated for different types of materials and structures. It includes a variety of MATLAB® examples to help readers absorb the content more easily.

  7. Polypyrrole–gold nanoparticle composites for highly sensitive DNA detection

    International Nuclear Information System (INIS)

    Spain, Elaine; Keyes, Tia E.; Forster, Robert J.

    2013-01-01

    DNA capture surfaces represent a powerful approach to developing highly sensitive sensors for identifying the cause of infection. Electrochemically deposited polypyrrole, PPy, films have been functionalized with electrodeposited gold nanoparticles to give a nanocomposite material, PPy–AuNP. Thiolated capture strand DNA, that is complementary to the sequence from the pathogen Staphylococcus aureus that causes mammary gland inflammation, was then immobilized onto the gold nanoparticles and any of the underlying gold electrode that is exposed. A probe strand, labelled with horse radish peroxidase, HRP, was then hybridized to the target. The concentration of the target was determined by measuring the current generated by reducing benzoquinone produced by the HRP label. Semi-log plots of the pathogen DNA concentration vs. faradaic current are linear from 150 pM to 1 μM and pM concentrations can be detected without the need for molecular, e.g., PCR or NASBA, amplification. The nanocomposite also exhibits excellent selectivity and single base mismatches in a 30 mer sequence can be detected

  8. Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

    International Nuclear Information System (INIS)

    Hashimoto, H.; Nakajima, K.; Suzuki, M.; Kimura, K.; Sasakawa, K.

    2011-01-01

    The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

  9. Highly sensitive MoS2 photodetectors with graphene contacts

    Science.gov (United States)

    Han, Peize; St. Marie, Luke; Wang, Qing X.; Quirk, Nicholas; El Fatimy, Abdel; Ishigami, Masahiro; Barbara, Paola

    2018-05-01

    Two-dimensional materials such as graphene and transition metal dichalcogenides (TMDs) are ideal candidates to create ultra-thin electronics suitable for flexible substrates. Although optoelectronic devices based on TMDs have demonstrated remarkable performance, scalability is still a significant issue. Most devices are created using techniques that are not suitable for mass production, such as mechanical exfoliation of monolayer flakes and patterning by electron-beam lithography. Here we show that large-area MoS2 grown by chemical vapor deposition and patterned by photolithography yields highly sensitive photodetectors, with record shot-noise-limited detectivities of 8.7 × 1014 Jones in ambient condition and even higher when sealed with a protective layer. These detectivity values are higher than the highest values reported for photodetectors based on exfoliated MoS2. We study MoS2 devices with gold electrodes and graphene electrodes. The devices with graphene electrodes have a tunable band alignment and are especially attractive for scalable ultra-thin flexible optoelectronics.

  10. Ultra-high sensitivity imaging of cancer using SERRS nanoparticles

    Science.gov (United States)

    Kircher, Moritz F.

    2016-05-01

    "Surface-enhanced Raman spectroscopy" (SERS) nanoparticles have gained much attention in recent years for in silico, in vitro and in vivo sensing applications. Our group has developed novel generations of biocompatible "surfaceenhanced resonance Raman spectroscopy" (SERRS) nanoparticles as novel molecular imaging agents. Via rigorous optimization of the different variables contributing to the Raman enhancement, we were able to design SERRS nanoparticles with so far unprecedented sensitivity of detection under in vivo imaging conditions (femto-attomolar range). This has resulted in our ability to visualize, with a single nanoparticle, many different cancer types (after intravenous injection) in mouse models. The cancer types we have tested so far include brain, breast, esophagus, stomach, pancreas, colon, sarcoma, and prostate cancer. All mouse models used are state-of-the-art and closely mimic the tumor biology in their human counterparts. In these animals, we were able to visualize not only the bulk tumors, but importantly also microscopic extensions and locoregional satellite metastases, thus delineating for the first time the true extent of tumor spread. Moreover, the particles enable the detection of premalignant lesions. Given their inert composition they are expected to have a high chance for clinical translation, where we envision them to have an impact in various scenarios ranging from early detection, image-guidance in open or minimally invasive surgical procedures, to noninvasive imaging in conjunction with spatially offset (SESORS) Raman detection devices.

  11. Characterization of three high efficiency and blue sensitive silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Otte, Adam Nepomuk, E-mail: otte@gatech.edu; Garcia, Distefano; Nguyen, Thanh; Purushotham, Dhruv

    2017-02-21

    We report about the optical and electrical characterization of three high efficiency and blue sensitive Silicon photomultipliers from FBK, Hamamatsu, and SensL. Key features of the tested devices when operated at 90% breakdown probability are peak photon detection efficiencies between 40% and 55%, temperature dependencies of gain and PDE that are less than 1%/°C, dark rates of ∼50 kHz/mm{sup 2} at room temperature, afterpulsing of about 2%, and direct optical crosstalk between 6% and 20%. The characteristics of all three devices impressively demonstrate how the Silicon-photomultiplier technology has improved over the past ten years. It is further demonstrated how the voltage and temperature characteristics of a number of quantities can be parameterized on the basis of physical models. The models provide a deeper understanding of the device characteristics over a wide bias and temperature range. They also serve as examples how producers could provide the characteristics of their SiPMs to users. A standardized parameterization of SiPMs would enable users to find the optimal SiPM for their application and the operating point of SiPMs without having to perform measurements thus significantly reducing design and development cycles.

  12. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay.

    Science.gov (United States)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-08-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.

  13. Integration of a highly ordered gold nanowires array with glucose oxidase for ultra-sensitive glucose detection.

    Science.gov (United States)

    Cui, Jiewu; Adeloju, Samuel B; Wu, Yucheng

    2014-01-27

    A highly sensitive amperometric nanobiosensor has been developed by integration of glucose oxidase (GO(x)) with a gold nanowires array (AuNWA) by cross-linking with a mixture of glutaraldehyde (GLA) and bovine serum albumin (BSA). An initial investigation of the morphology of the synthesized AuNWA by field emission scanning electron microscopy (FESEM) and field emission transmission electron microscopy (FETEM) revealed that the nanowires array was highly ordered with rough surface, and the electrochemical features of the AuNWA with/without modification were also investigated. The integrated AuNWA-BSA-GLA-GO(x) nanobiosensor with Nafion membrane gave a very high sensitivity of 298.2 μA cm(-2) mM(-1) for amperometric detection of glucose, while also achieving a low detection limit of 0.1 μM, and a wide linear range of 5-6000 μM. Furthermore, the nanobiosensor exhibited excellent anti-interference ability towards uric acid (UA) and ascorbic acid (AA) with the aid of Nafion membrane, and the results obtained for the analysis of human blood serum indicated that the device is capable of glucose detection in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. The preventive effects of natural adjuvants, G2 and G2F on tracheal responsiveness and serum IL-4 and IFN-γ (th1/th2 balance in sensitized guinea pigs

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Boskabady

    2014-07-01

    Full Text Available OBJECTIVE:The effects of natural adjuvants on lung inflammation and tracheal responsiveness were examined in sensitized guinea pigs.METHODS:The responses of guinea pig tracheal chains and the serum levels of interleukin-4 and interferon-gamma were examined in control pigs and three other groups of guinea pigs: the sensitized group and two other sensitized groups treated with either adjuvant G2 or adjuvant G2F (n = 7 for each group. Sensitization of the animals was achieved by injection and inhalation of ovalbumin.RESULTS:The results showed that sensitized animals had increased tracheal responsiveness and increased serum levels of interleukin-4 and interferon-gamma compared to controls (p<0.05 to p<0.001. Treatments with either G2 or G2F prevented the increase in tracheal responsiveness and serum interleukin-4 (p<0.01 to p<0.001. However, the serum levels of interferon-gamma and the interleukin-4-to-interferon-gamma ratio was increased in the treated groups (p<0.001 for all cases.CONCLUSIONS:These results indicate important preventive effects of two natural adjuvants, particularly G2, on the changes in tracheal responsiveness, serum cytokines and the interleukin-4-to-interferon-gamma ratio (T helper 1/T helper 2 balance in sensitized guinea pigs.

  15. Introducing wet aerosols into the static high sensitivity ICP (SHIP)

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, Andy; Engelhard, Carsten; Sperling, Michael; Buscher, Wolfgang [University of Muenster, Institute of Inorganic and Analytical Chemistry, Muenster (Germany)

    2007-08-15

    A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3-0.5 L min{sup -1}) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min{sup -1} for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min{sup -1} for the plasma gas and 0.44 L min{sup -1} for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97-103% for 13 elements, measured simultaneously. (orig.)

  16. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    Science.gov (United States)

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health. Copyright © 2015 the American Physiological Society.

  17. Is High Serum LDL/HDL Cholesterol Ratio an Emerging Risk Factor for Sudden Cardiac Death? Findings from the KIHD Study.

    Science.gov (United States)

    Kunutsor, Setor K; Zaccardi, Francesco; Karppi, Jouni; Kurl, Sudhir; Laukkanen, Jari A

    2017-06-01

    Low-density lipoprotein cholesterol (LDL-c) and high-density lipoprotein cholesterol (HDL-c), which are components of total cholesterol, have each been suggested to be linked to the risk of sudden cardiac death (SCD). However, the relationship between LDL-c/HDL-c ratio and the risk of SCD has not been previously investigated. We aimed to assess the associations of LDL-c, HDL-c, and the ratio of LDL-c/HDL-c with the risk of SCD. Serum lipoprotein concentrations were assessed at baseline in the Finnish Kuopio Ischemic Heart Disease prospective cohort study of 2,616 men aged 42-61 years at recruitment. Hazard ratios (HRs) (95% confidence intervals [CI]) were assessed. During a median follow-up of 23.0 years, a total of 228 SCDs occurred. There was no significant evidence of an association of LDL-c or HDL-c with the risk of SCD. In analyses adjusted for age, examination year, body mass index, systolic blood pressure, smoking, alcohol consumption, physical activity, years of education, diabetes, previous myocardial infarction, family history of coronary heart disease, and serum high sensitivity C-reactive protein, there was approximately a two-fold increase in the risk of SCD (HR 1.94, 95% CI 1.21-3.11; p=0.006), comparing the top (>4.22) versus bottom (≤2.30) quintile of serum LDL-c/HDL-c ratio. In this middle-aged male population, LDL-c or HDL-c was not associated with the risk of SCD. However, a high serum LDL-c/HDL-c ratio was found to be independently associated with an increased risk of SCD. Further research is warranted to understand the mechanistic pathways underlying this association.

  18. Early weight changes after birth and serum high-molecular-weight adiponectin level in preterm infants.

    Science.gov (United States)

    Yoshida, Tomohide; Nagasaki, Hiraku; Asato, Yoshihide; Ohta, Takao

    2011-12-01

    Extra-uterine growth retardation (EUGR) is associated with an increased risk for cardiometabolic diseases later in life. The aim of the present study was to examine the relationship between early weight change after birth in preterm infants and adiponectin (adn) multimeric complexes. Subjects included 28 preterm infants born between weeks 24 and 33 of gestation. Serum adn multimeric complexes and the anthropometric parameters were measured in preterm infants at birth and at corrected term. Bodyweight (BW) decreased during the first week of life, with birthweight restored at approximately 19 days after birth. Nineteen of the subjects had EUGR at corrected term. Total (T)-adn, high-molecular-weight (H)-adn, and the ratio of H-adn to T-adn (H/T-adn) were significantly elevated at corrected term than at birth. Postmenstrual age, birthweight, birth length and lowest BW after birth were positively correlated with H-adn and H/T-adn. Weight reduction after birth was negatively correlated with H-adn. Age to restore birthweight was negatively correlated with T-adn, H-adn and H/T-adn. Stepwise multiple regression analysis indicated age to restore birthweight as the major predictor of T-adn and H-adn. Early weight changes after birth may alter serum adn level in preterm infants at corrected term. The appropriate nutritional support in the early postnatal period could reduce the prevalence of EUGR and the future risk for cardiometabolic diseases. © 2011 The Authors. Pediatrics International © 2011 Japan Pediatric Society.

  19. Separation of hemagglutination-inhibiting immunoglobulin M antibody to rubella virus in human serum by high-performance liquid chromatography.

    OpenAIRE

    Kobayashi, N; Suzuki, M; Nakagawa, T; Matumoto, M

    1986-01-01

    High-performance liquid chromatography was successfully used to separate hemagglutination-inhibiting immunoglobulin M (IgM) rubella virus antibody from IgG rubella virus antibody in human serum. The fractionation by high-performance liquid chromatography was as effective as sucrose density gradient centrifugation in separating IgM antibody from IgG antibody.

  20. Microsatellite instability typing in serum and tissue of patients with colorectal cancer: comparing real time PCR with hybridization probe and high-performance liquid chromatography.

    Science.gov (United States)

    Mokarram, P; Rismanchi, M; Alizadeh Naeeni, M; Mirab Samiee, S; Paryan, M; Alipour, A; Honardar, Z; Kavousipour, S; Naghibalhossaini, F; Mostafavi-Pour, Z; Monabati, A; Hosseni, S V; Shamsdin, S A

    2014-05-01

    Allelic variation of BAT-25 (a 25-repeat quasimonomorphic poly T) and BAT-26 (a 26-repeat quasimonomorphic polyA) loci as two mononucleotide microsatellite markers, were analyzed with high-performance liquid chromatography (HPLC) compared with Real-Time PCR using hybridization probes. BAT-26 and BAT-25 markers were used to determine an appropriate screening technique with high sensitivity and specificity to diagnose microsatellite instability (MSI) status in patients with colorectal cancer (CRC). One of the pathways in colorectal tumor genesis is microsatellite instability (MSI+). MSI is detected in about 15% of all CRCs; 3% are of these are associated with Lynch syndrome and the other 12% are caused by sporadic. Colorectal tumors with MSI have distinctive features compared with microsatellite stable tumors. Due to the high percentage of MSI+ CRC in Iran, screening of this type of CRC is imperative. Two markers were analyzed in tissues and sera of 44 normal volunteers and tumor and matched normal mucosal tissues as well as sera of 44 patients with sporadic CRC. The sensitivity and specificity of BAT-26 with real time PCR method (Hybridization probe) were 100% in comparison with sequencing method as the gold standard, while HPLC had a lower sensitivity and specificity. According to HPLC data, BAT-26 was more sensitive than BAT-25 in identifying MSI tumors. Therefore, MSI typing using the BAT-26 hybridization probe method compared to HPLC could be considered as an accurate method for diagnosing MSI in CRC tumors but not in serum circulating DNAs.

  1. High serum uric acid concentration predicts poor survival in patients with breast cancer.

    Science.gov (United States)

    Yue, Cai-Feng; Feng, Pin-Ning; Yao, Zhen-Rong; Yu, Xue-Gao; Lin, Wen-Bin; Qian, Yuan-Min; Guo, Yun-Miao; Li, Lai-Sheng; Liu, Min

    2017-10-01

    Uric acid is a product of purine metabolism. Recently, uric acid has gained much attraction in cancer. In this study, we aim to investigate the clinicopathological and prognostic significance of serum uric acid concentration in breast cancer patients. A total of 443 female patients with histopathologically diagnosed breast cancer were included. After a mean follow-up time of 56months, survival was analysed using the Kaplan-Meier method. To further evaluate the prognostic significance of uric acid concentrations, univariate and multivariate Cox regression analyses were applied. Of the clinicopathological parameters, uric acid concentration was associated with age, body mass index, ER status and PR status. Univariate analysis identified that patients with increased uric acid concentration had a significantly inferior overall survival (HR 2.13, 95% CI 1.15-3.94, p=0.016). In multivariate analysis, we found that high uric acid concentration is an independent prognostic factor predicting death, but insufficient to predict local relapse or distant metastasis. Kaplan-Meier analysis indicated that high uric acid concentration is related to the poor overall survival (p=0.013). High uric acid concentration predicts poor survival in patients with breast cancer, and might serve as a potential marker for appropriate management of breast cancer patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. High-sensitivity Cardiac Troponin Elevation after Electroconvulsive Therapy (ECT)

    Science.gov (United States)

    Duma, Andreas; Pal, Swatilika; Johnston, Joshua; Helwani, Mohammad A.; Bhat, Adithya; Gill, Bali; Rosenkvist, Jessica; Cartmill, Christopher; Brown, Frank; Miller, J. Philip; Scott, Mitchell G; Sanchez-Conde, Francisco; Jarvis, Michael; Farber, Nuri B.; Zorumski, Charles F.; Conway, Charles; Nagele, Peter

    2017-01-01

    Background While electroconvulsive therapy (ECT) is widely regarded as a life-saving and safe procedure, evidence regarding its effects on myocardial cell injury are sparse. The objective of this investigation was to determine incidence and magnitude of new cardiac troponin elevation after ECT using a novel high-sensitivity cardiac troponin I (hscTnI) assay. Methods This was a prospective cohort study in adult patients undergoing ECT in a single academic center (up to three ECT treatments per patient). The primary outcome was new hscTnI elevation after ECT, defined as an increase of hscTnI >100% after ECT compared to baseline with at least one value above the limit of quantification (10 ng/L). 12-lead ECG and hscTnI values were obtained prior to and 15–30 minutes after ECT; in a subset of patients an additional 2-hour hscTnI value was obtained. Results The final study population was 100 patients and a total of 245 ECT treatment sessions. Eight patients (8/100, 8%) experienced new hscTnI elevation after ECT with a cumulative incidence of 3.7% (9/245 treatments; one patient had two hscTnI elevations), two of whom had a non-ST-elevation myocardial infarction (incidence 2/245, 0.8%). Median hscTnI concentrations did not increase significantly after ECT. Tachycardia and/or elevated systolic blood pressure developed after approximately two thirds of ECT treatments. Conclusions ECT appears safe from a cardiac standpoint in a large majority of patients. A small subset of patients with pre-existing cardiovascular risk factors, however, may develop new cardiac troponin elevation after ECT, the clinical relevance of which is unclear in the absence of signs of myocardial ischemia. PMID:28166110

  3. Time-Resolved Fluorescence of Water-Soluble Pyridinium Salt: Sensitive Detection of the Conformational Changes of Bovine Serum Albumin.

    Science.gov (United States)

    Li, Lei; Yi, Hua; Jia, Menghui; Chang, Mengfang; Zhou, Zhongneng; Zhang, Sanjun; Pan, Haifeng; Chen, Yan; Chen, Jinquan; Xu, Jianhua

    2016-06-20

    In this paper, we report a pyridinium salt "turn-on" fluorescent probe, 4-[2-(4-Dimethylamino-phenyl)-vinyl]-1-methylpyridinium iodide (p-DASPMI), and applied its time-resolved fluorescence (TRF) to monitor the protein conformational changes. Both the fluorescence lifetime and quantum yield (QY) of p-DASPMI were increased about two orders of magnitude after binding to the protein bovine serum albumin (BSA). The free p-DASPMI in solution presents an ultrashort fluorescence lifetime (12.4 ps), thus it does not interfere the detection of bound p-DASPMI which has nanosecond fluorescence lifetime. Decay-associated spectra (DAS) show that p-DASPMI molecules bind to subdomains IIA and IIIA of BSA. The TRF decay profiles of p-DASPMI can be described by multi-exponential decay function ([Formula: see text]), and the obtained parameters, such as lifetimes ([Formula: see text]), fractional amplitudes ([Formula: see text]), and fractional intensities ([Formula: see text]), may be used to deduce the conformational changes of BSA. The pH and Cu 2+ induced conformational changes of BSA were investigated through the TRF of p-DASPMI. The results show that the p-DASPMI is a candidate fluorescent probe in studying the conformational changes of proteins through TRF spectroscopy and microscopy in the visible range. © The Author(s) 2016.

  4. Development of gel-filter method for high enrichment of low-molecular weight proteins from serum.

    Directory of Open Access Journals (Sweden)

    Lingsheng Chen

    Full Text Available The human serum proteome has been extensively screened for biomarkers. However, the large dynamic range of protein concentrations in serum and the presence of highly abundant and large molecular weight proteins, make identification and detection changes in the amount of low-molecular weight proteins (LMW, molecular weight ≤ 30kDa difficult. Here, we developed a gel-filter method including four layers of different concentration of tricine SDS-PAGE-based gels to block high-molecular weight proteins and enrich LMW proteins. By utilizing this method, we identified 1,576 proteins (n = 2 from 10 μL serum. Among them, 559 (n = 2 proteins belonged to LMW proteins. Furthermore, this gel-filter method could identify 67.4% and 39.8% more LMW proteins than that in representative methods of glycine SDS-PAGE and optimized-DS, respectively. By utilizing SILAC-AQUA approach with labeled recombinant protein as internal standard, the recovery rate for GST spiked in serum during the treatment of gel-filter, optimized-DS, and ProteoMiner was 33.1 ± 0.01%, 18.7 ± 0.01% and 9.6 ± 0.03%, respectively. These results demonstrate that the gel-filter method offers a rapid, highly reproducible and efficient approach for screening biomarkers from serum through proteomic analyses.

  5. Serum high molecular weight complex of adiponectin correlates better with glucose tolerance than total serum adiponectin in Indo-Asian males.

    Science.gov (United States)

    Fisher, F F M; Trujillo, M E; Hanif, W; Barnett, A H; McTernan, P G; Scherer, P E; Kumar, S

    2005-06-01

    It is well established that total systemic adiponectin is reduced in type 2 diabetic subjects. To date most studies have been concerned with the singular full-length protein or proteolytically cleaved globular domain. It is, however, apparent that the native protein circulates in serum as a lower molecular weight hexamer and as larger multimeric structures of high molecular weight (HMW). In this study we address the clinical significance of each form of the protein with respect to glucose tolerance. Serum was obtained from 34 Indo-Asian male subjects (BMI 26.5+/-3.1; age 52.15+/-10.14 years) who had undertaken a 2-h oral glucose tolerance test. An aliquot of serum was fractionated using velocity sedimentation followed by reducing SDS-PAGE. Western blots were probed for adiponectin, and HMW adiponectin as a percentage of total adiponectin (percentage of higher molecular weight adiponectin [S(A)] index) was calculated from densitometry readings. Total adiponectin was measured using ELISA; leptin, insulin and IL-6 were determined using ELISA. Analysis of the cohort demonstrated that total adiponectin (r = 0.625, p = 0.0001), fasting insulin (r = -0.354, p = 0.040) and age (r = 0.567, p = 0.0001) correlated with S(A). S(A) showed a tighter, inverse correlation with 2-h glucose levels (r = -0.58, p = 0.0003) than total adiponectin (r = -0.38, p = 0.0001). This study demonstrates the importance of the S(A) index as a better determinant of glucose intolerance than measurements of total adiponectin. Our findings suggest that HMW adiponectin is the active form of the protein.

  6. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  7. Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor

    Directory of Open Access Journals (Sweden)

    Das G

    2015-08-01

    Full Text Available Gautam Das, Thao Quynh Ngan Tran, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Republic of South Korea Abstract: In this work, three different spherulitic nanostructures Cu–CuOA, Cu–CuOB, and Cu–CuOC were synthesized in water-in-oil microemulsions by varying the surfactant concentration (30 mM, 40 mM, and 50 mM, respectively. The structural and morphological characteristics of the Cu–CuO nanostructures were investigated by ultraviolet–visible (UV–vis spectroscopy, X-ray diffraction, scanning electron microscopy, and high-resolution transmission electron microscopy techniques. The synthesized nanostructures were deposited on multiwalled carbon nanotube (MWCNT-modified indium tin oxide (ITO electrodes to fabricate a nonenzymatic highly sensitive amperometric glucose sensor. The performance of the ITO/MWCNT/Cu–CuO electrodes in the glucose assay was examined by cyclic voltammetry and chronoamperometric studies. The sensitivity of the sensor varied with the spherulite type; Cu–CuOA, Cu–CuOB, and Cu–CuOC exhibited a sensitivity of 1,229, 3,012, and 3,642 µA mM-1·cm-2, respectively. Moreover, the linear range is dependent on the structure types: 0.023–0.29 mM, 0.07–0.8 mM, and 0.023–0.34 mM for Cu–CuOA, Cu–CuOB, and Cu–CuOC, respectively. An excellent response time of 3 seconds and a low detection limit of 2 µM were observed for Cu–CuOB at an applied potential of +0.34 V. In addition, this electrode was found to be resistant to interference by common interfering agents such as urea, cystamine, l-ascorbic acid, and creatinine. The high performance of the Cu–CuO spherulites with nanowire-to-nanorod outgrowths was primarily due to the high surface area and stability, and good three-dimensional structure. Furthermore, the ITO/MWCNT/Cu–CuOB electrode applied to real urine and serum sample showed satisfactory performance. Keywords: copper oxide, multiwalled

  8. Development of high sensitivity and high speed large size blank inspection system LBIS

    Science.gov (United States)

    Ohara, Shinobu; Yoshida, Akinori; Hirai, Mitsuo; Kato, Takenori; Moriizumi, Koichi; Kusunose, Haruhiko

    2017-07-01

    The production of high-resolution flat panel displays (FPDs) for mobile phones today requires the use of high-quality large-size photomasks (LSPMs). Organic light emitting diode (OLED) displays use several transistors on each pixel for precise current control and, as such, the mask patterns for OLED displays are denser and finer than the patterns for the previous generation displays throughout the entire mask surface. It is therefore strongly demanded that mask patterns be produced with high fidelity and free of defect. To enable the production of a high quality LSPM in a short lead time, the manufacturers need a high-sensitivity high-speed mask blank inspection system that meets the requirement of advanced LSPMs. Lasertec has developed a large-size blank inspection system called LBIS, which achieves high sensitivity based on a laser-scattering technique. LBIS employs a high power laser as its inspection light source. LBIS's delivery optics, including a scanner and F-Theta scan lens, focus the light from the source linearly on the surface of the blank. Its specially-designed optics collect the light scattered by particles and defects generated during the manufacturing process, such as scratches, on the surface and guide it to photo multiplier tubes (PMTs) with high efficiency. Multiple PMTs are used on LBIS for the stable detection of scattered light, which may be distributed at various angles due to irregular shapes of defects. LBIS captures 0.3mμ PSL at a detection rate of over 99.5% with uniform sensitivity. Its inspection time is 20 minutes for a G8 blank and 35 minutes for G10. The differential interference contrast (DIC) microscope on the inspection head of LBIS captures high-contrast review images after inspection. The images are classified automatically.

  9. Liver lipase and high-density lipoprotein. Lipoprotein changes after incubation of human serum with rat liver lipase.

    Science.gov (United States)

    Groot, P H; Scheek, L M; Jansen, H

    1983-05-16

    Human sera were incubated with rat liver lipase after inactivation of lecithin:cholesterol acyltransferase, and the changes in serum lipoprotein composition were measured. In the presence of liver lipase serum triacylglycerol and phosphatidylcholine were hydrolyzed. The main changes in the concentrations of these lipids were found in the high-density lipoprotein fraction. Subfractionation of high-density lipoprotein by rate-zonal ultracentrifugation showed a prominent decrease in all constituents of high-density lipoprotein2, a smaller decrease in the 'light' high-density lipoprotein3 and an increase in the 'heavy' high-density lipoprotein3. These data support a concept in which liver lipase is involved in high-density lipoprotein2 phospholipid and triacylglycerol catabolism and suggest that as a result of this action high-density lipoprotein2 is converted into high-density lipoprotein3.

  10. Analysis of the variation levels of APN, insulin, sensitive C-reactive protein and leptin in the serum of patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Du Tongxing; Wang Zizheng; Wang Shukui; Qi Shaokang; Tao Xiaojun

    2005-01-01

    To study the mechanism of pancreatic 13 cell dysfunction and tissue resistance to insulin, and to provide basis for early diagnosis and therapy of the disease, the levels of APN, insulin, sensitive C-reactive protein and leptin in the serum of patients with type 2 diabetes mellitus were determined. Altogether 184 untreatea type 2 diabetes mellitus patients, 30 normal people as the control group, and another 75 type 2 diabetes mellitus patients who have been treated for a year were enrolled in this study. The serum levels of the above indexes were determined by chemiluminescence immunoassay, enzyme immunoassay and radioimmunoassay. The results showed that there were obvious differences in the levels of insulin, leptin, C-reacting protein and insulin antibody between the normal control group and the group of the untreated type 2 diabetes mellitus patients (P<0.01), especially there was significant difference in the level of APN(P<0. 001). Among the 75 type 2 diabetes meltitus patients who have received a year's treatment, all the indexes except for APN and insulin antibody were decreased statistically, while the APN level was increased significantly (P<0.01) than that before the treatment. The determination of markers of type 2 diabetes mellitus is of great significance for its early diagnosis, therapy, prognosis and mechanism research. (authors)

  11. Rapid determination of 18 glucocorticoids in serum using reusable on-line SPE polymeric monolithic column coupled with LC-quadrupole/orbitrap high-resolution mass spectrometer.

    Science.gov (United States)

    Li, Hui; Ai, Lianfeng; Fan, Sufang; Wang, Yan; Sun, Dianxing

    2017-10-15

    A simple, rapid and sensitive method for the simultaneous determination of 18 glucocorticoids in serum was developed by coupling on-line solid-phase extraction (SPE) polymeric monolithic column to a liquid chromatography-quadrupole/orbitrap high-resolution mass spectrometer. A simple poly(ethylene glycol dimethacrylate) monolith column (10mm×2.1mm i.d.) was fabricated, and the morphology, surface area and extraction performance of the monolithic column were characterized. Serum samples were extracted by acetonitrile (ACN). Then, online SPE was achieved on the synthesized monolithic column using a 10mmol/L ammonium acetate solution as the loading solvent. After the transfer from the monolith into analytical column (Capcell Pak ADME column) using ACN, the adsorbed analytes were separated on the analytical column and detected with a high-resolution hybrid quadrupole/orbitrap mass spectrometer with full scan/ddMS 2 scan mode Under optimized conditions, the method was linear with target linear correlation coefficient (R 2 ) higher than 0.995. Detection limits were in range of 0.1-0.6ng/mL, and the quantification limits were 0.3-1.5ng/mL. The recovery was between 71.9% and 89.2% in three spike levels with precision (n=5) of 5.40-12.1%. The serum sample was directly analyzed after a simple extraction procedure, and the on-line SPE and determination were achieved within only 16min. The method was used to analyze the dynamic contents variation of cortisone and hydrocortisone in serum before and after the surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Model dependence of isospin sensitive observables at high densities

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Wen-Mei [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); School of Science, Huzhou Teachers College, Huzhou 313000 (China); Yong, Gao-Chan, E-mail: yonggaochan@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China); Wang, Yongjia [School of Science, Huzhou Teachers College, Huzhou 313000 (China); School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); Li, Qingfeng [School of Science, Huzhou Teachers College, Huzhou 313000 (China); Zhang, Hongfei [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China); Zuo, Wei [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2013-10-07

    Within two different frameworks of isospin-dependent transport model, i.e., Boltzmann–Uehling–Uhlenbeck (IBUU04) and Ultrarelativistic Quantum Molecular Dynamics (UrQMD) transport models, sensitive probes of nuclear symmetry energy are simulated and compared. It is shown that neutron to proton ratio of free nucleons, π{sup −}/π{sup +} ratio as well as isospin-sensitive transverse and elliptic flows given by the two transport models with their “best settings”, all have obvious differences. Discrepancy of numerical value of isospin-sensitive n/p ratio of free nucleon from the two models mainly originates from different symmetry potentials used and discrepancies of numerical value of charged π{sup −}/π{sup +} ratio and isospin-sensitive flows mainly originate from different isospin-dependent nucleon–nucleon cross sections. These demonstrations call for more detailed studies on the model inputs (i.e., the density- and momentum-dependent symmetry potential and the isospin-dependent nucleon–nucleon cross section in medium) of isospin-dependent transport model used. The studies of model dependence of isospin sensitive observables can help nuclear physicists to pin down the density dependence of nuclear symmetry energy through comparison between experiments and theoretical simulations scientifically.

  13. Serum immunoreactive erythropoietin in high altitude natives with and without excessive erythrocytosis.

    Science.gov (United States)

    León-Velarde, F; Monge, C C; Vidal, A; Carcagno, M; Criscuolo, M; Bozzini, C E

    1991-05-01

    We report the estimation of blood hemoglobin (Hb), arterial blood oxygen saturation (SaO2), and serum immunoreactive erythropoietin (siEPO) in a group of Peruvian workers residing in Cerro de Pasco at 4300 m showing "excessive erythrocytosis" (EE, Monge's disease, chronic mountain sickness). These estimates were compared with those of humans residing either in Cerro de Pasco and showing "normal erythrocytosis" (NE) or in Lima (sea level, SL) to determine whether Hb and SaO2 are related to siEPO in high altitude (HA) natives with NE or EE. The three parameters showed statistically significant differences between HA and SL groups--the values in SL being lower. Significant differences were also found between NE and EE groups in Hb and SaO2. There was no statistical difference in siEPo between the two groups. The results indicate, therefore, that HA residents who develop EE are not distinguishable from residents who develop NE on the basis of estimates of siEPO. As a result, siEPO and Hb do not show a dose-response relationship in HA residents, and variation in EPO does not explain the striking variation in Hb at high altitudes.

  14. Low IDL-B and high LDL-1 subfraction levels in serum of ALS patients.

    Science.gov (United States)

    Delaye, J B; Patin, F; Piver, E; Bruno, C; Vasse, M; Vourc'h, P; Andres, C R; Corcia, P; Blasco, H

    2017-09-15

    Converging evidence highlights that lipid metabolism plays a key role in ALS pathophysiology. Dyslipidemia has been described in ALS patients and may be protective but peripheral lipoprotein subclasses have never been studied. We collected sera from 30 ALS patients and 30 gender and age-matched controls. We analyzed 11 distinct lipoprotein subclasses by linear polyacrylamide gel electrophoresis (Lipoprint, Quantimetrix Corporation, USA). We also measured lipoprotein (a), apolipoprotein B, and apolipoprotein E levels. ALS patients had significant higher total cholesterol, HDL-cholesterol, and LDL-cholesterol levels than controls (pALS patients than controls. Our preliminary work confirmed the association between ALS and dyslipidemia. The low IDL-B levels may explain the hepatic steatosis frequently reported in ALS. The high levels of the cholesterol-rich LDL-1 subfraction is consistent with previously reported hypercholesterolemia. This study describes, for the first time, the distribution of serum lipoproteins in ALS patients, with low IDL-B and high LDL-1 subfraction level. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Obesity, Inflammation and Acute Myocardial Infarction - Expression of leptin, IL-6 and high sensitivity-CRP in Chennai based population

    Directory of Open Access Journals (Sweden)

    Rajendran Karthick

    2012-08-01

    Full Text Available Abstract Background Obesity, characterised by increased fat mass and is currently regarded as a pro-inflammatory state and often associated with increased risk of cardiovascular diseases (CVD including Myocardial infarction. There is an upregulation of inflammatory markers such as interleukin-6, interleukin-6 receptor and acute phase protein CRP in Acute Myocardial Infarction (AMI patients but the exact mechanism linking obesity and inflammation is not known. It is of our interest to investigate if serum leptin (ob gene product is associated with AMI and correlated with inflammatory proteins namely Interleukin-6 (IL-6 and high sensitivity - C reactive protein (hs-CRP. Results Serum leptin levels were significantly higher in AMI patients when compared to Non-CVD controls. IL-6 and hs-CRP were also elevated in the AMI group and leptin correlated positively with IL-6 and hs-CRP. Incidentally this is the first report from Chennai based population, India. Conclusions The strong correlation between serum levels of leptin and IL-6 implicates an involvement of leptin in the upregulation of inflammatory cytokines during AMI. We hypothesise that the increase in values of IL-6, hs-CRP and their correlation to leptin in AMI patients could be due to participation of leptin in the signaling cascade after myocardial ischemia.

  16. Obesity, Inflammation and Acute Myocardial Infarction - Expression of leptin, IL-6 and high sensitivity-CRP in Chennai based population.

    Science.gov (United States)

    Rajendran, Karthick; Devarajan, Nalini; Ganesan, Manohar; Ragunathan, Malathi

    2012-08-14

    Obesity, characterised by increased fat mass and is currently regarded as a pro-inflammatory state and often associated with increased risk of cardiovascular diseases (CVD) including Myocardial infarction. There is an upregulation of inflammatory markers such as interleukin-6, interleukin-6 receptor and acute phase protein CRP in Acute Myocardial Infarction (AMI) patients but the exact mechanism linking obesity and inflammation is not known. It is of our interest to investigate if serum leptin (ob gene product) is associated with AMI and correlated with inflammatory proteins namely Interleukin-6 (IL-6) and high sensitivity - C reactive protein (hs-CRP). Serum leptin levels were significantly higher in AMI patients when compared to Non-CVD controls. IL-6 and hs-CRP were also elevated in the AMI group and leptin correlated positively with IL-6 and hs-CRP. Incidentally this is the first report from Chennai based population, India. The strong correlation between serum levels of leptin and IL-6 implicates an involvement of leptin in the upregulation of inflammatory cytokines during AMI. We hypothesise that the increase in values of IL-6, hs-CRP and their correlation to leptin in AMI patients could be due to participation of leptin in the signaling cascade after myocardial ischemia.

  17. The analysis of high sensitive C-reactive protein and diabetic nephropathy in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Xu Yan

    2007-01-01

    Objective: To investigate the changes of serum high sensitive C-reactive protein (hs-CRP) in different stages of diabetic nephropathy and their clinical significance. Methods: Serum hs-CRP was measured by enzyme-linked immunosorbent assay (ELISA), U-Alb was measured by radioimmunoassay(RIA). According to their urinary albumin excretion rate(UAER), 102 patients with type 2 diabetes mellitus were divided into three groups: 40 patients with normal UAER, 32 patients with microalbuminuria and 30 patients with clinical proteinuria, and 32 healthy subjects were taken as the controls control. Results: hs-CRP concentrations were significantly higher in patients with type 2 diabetes mellitus than those in healthy controls and increased with increment of UAER and serum creatinine. Conclusions: The level of hs-CRP is correlated with the extend of diabetic nephropathy in patients with type 2 diabetic patients.The concentration of hs-CRP can in some degree serve as a predictor for diabetic rephropathy and its progression. (authors)

  18. A soluble form of the high affinity IgE receptor, Fc-epsilon-RI, circulates in human serum.

    Directory of Open Access Journals (Sweden)

    Eleonora Dehlink

    Full Text Available Soluble IgE receptors are potential in vivo modulators of IgE-mediated immune responses and are thus important for our basic understanding of allergic responses. We here characterize a novel soluble version of the IgE-binding alpha-chain of Fc-epsilon-RI (sFcεRI, the high affinity receptor for IgE. sFcεRI immunoprecipitates as a protein of ∼40 kDa and contains an intact IgE-binding site. In human serum, sFcεRI is found as a soluble free IgE receptor as well as a complex with IgE. Using a newly established ELISA, we show that serum sFcεRI levels correlate with serum IgE in patients with elevated IgE. We also show that serum of individuals with normal IgE levels can be found to contain high levels of sFcεRI. After IgE-antigen-mediated crosslinking of surface FcεRI, we detect sFcεRI in the exosome-depleted, soluble fraction of cell culture supernatants. We further show that sFcεRI can block binding of IgE to FcεRI expressed at the cell surface. In summary, we here describe the alpha-chain of FcεRI as a circulating soluble IgE receptor isoform in human serum.

  19. High contrast sensitivity for visually guided flight control in bumblebees.

    Science.gov (United States)

    Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie

    2017-12-01

    Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.

  20. Sustained high serum caspase-3 concentrations and mortality in septic patients.

    Science.gov (United States)

    Lorente, L; Martín, M M; Pérez-Cejas, A; González-Rivero, A F; López, R O; Ferreres, J; Solé-Violán, J; Labarta, L; Díaz, C; Palmero, S; Jiménez, A

    2018-02-01

    Caspase-3 is the main executor of the apoptotic process. Higher serum caspase-3 concentrations in non-survivor compared to survivor septic patients have been found. The objectives of this work (with the increase of sample size to 308 patients, and the determination of serum caspase-3 concentrations also on days 4 and 8 of diagnosis of severe sepsis) were to know whether an association between serum caspase-3 concentrationss during the first week, degree of apoptosis, sepsis severity, and sepsis mortality exists. We collected serum samples of 308 patients with severe sepsis from eight intensive care units on days 1, 4 and 8 to measure concentrations of caspase-3 and caspase-cleaved cytokeratin (CCCK)-18 (to assess degree of apoptosis). End point was 30-day mortality. We found higher serum concentrations of caspase-3 and CCCK-18 in non-survivors compared to survivors on days 1 (p < 0.001), 4 (p < 0.001), and 8 (p < 0.001). We found an association between serum caspase-3 concentrations on days 1, 4 and 8 of severe sepsis diagnosis and serum CCCK-18 concentrations (p < 0.001), SOFA (p < 0.001), serum acid lactic concentrations (p < 0.001), and 30-day sepsis mortality (p < 0.001). The new findings of this work were that an association between serum caspase-3 concentrations during the first week, apoptosis degree, sepsis severity, and sepsis mortality exists.

  1. Metal ion-organic compound for high sensitive ESR dosimetry

    International Nuclear Information System (INIS)

    Hassan, G.M.; Ikeya, Motoji

    2000-01-01

    A systematic study to find a tissue equivalent and high sensitive dosimeter material has been made to stimulate the field of ESR dosimetry. Lithium acetate dihydrate (Li-Ac·2H 2 O:CH 3 COOLi·2H 2 O) and lithium phosphate (Li-phosphate:Li 3 PO 4 ) were irradiated by γ-rays to study radicals with (ESR) in addition to magnesium lactate (Mg-lactate (CH 3 CH(OH)COO) 2 Mg) doped with nominal pure lithium lactate (Mg(Li)-lactate) and lithium lactate (CH 3 CH(OH)COOLi) doped with Mg-lactate (Li(Mg)-lactate). A triplet spectrum with intensity ratio of 1:2:1 in Li-Ac·2H 2 O was ascribed to acetate radical which has g=2.0031±0.0004 and hyperfine splitting of A/gβ=2.12±0.1 mT. The Li-phosphate spectrum shows splitting due to anisotropic g-factors of g par =2.0190±0.0005 and g perp =1.9974±0.0004. Quartet spectra with the intensity ratio of 1:3:3:1 in Mg(Li)-lactate and Li(Mg)-lactate were ascribed to lactate radicals with g-factors of 2.0032 ± 0.0004 and 2.0029 ± 0.0004 and the intensity ratio of 1:3:3:1 and A/gβ=1.92±0.06 and 1.82 ± 0.06 mT, respectively. The response to γ-ray dose and the thermal stability as well as the effect of UV-illumination have been studied. The obtained number of free radicals per 100 eV (G-values) were 0.4 ± 0.13, 1.02 ± 0.31, 1.35 ± 0.35 and 0.78 ± 0 for Li-Ac.2H 2 O, Li-phosphate, Mg(Li)-lactate, and Li(Mg)-lactate, respectively. The lifetimes were estimated from Arrhenius plots to be approximately 2.0 ± 0.6, 50.7 ± 20 and 10 ± 3.5 years for Li-phosphate, Mg(Li)-lactate and Li(Mg)-lactate, respectively. The lifetime for Li-Ac·2H 2 O cannot be estimated because of the decomposition by heating

  2. Clinical and biochemical assessment of high serum vitamin B12 levels

    DEFF Research Database (Denmark)

    Arendt, Johan Frederik Berg; Nexø, Ebba

    2012-01-01

    Introduction: Measurement of serum cobalamin (Cbl) is routinely used to assess suspected Cbl deficiency. Surprisingly, 15% of all samples analysed for serum Cbl show values above the reference range of 200-600 pmol/L. Aim: We hypothesized that increased Cbl levels are caused by alterations...... in the circulating Cbl binding proteins haptocorrin (HC) and/or transcobalamin (TC), and that such changes may be of clinical importance. Materials and methods: We collected 834 blood samples from hospital treated patients with serum Cbl levels: 1000 pmol/L. In-house ELISAs were used...

  3. Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Chunrui [Univ. of Texas, San Antonio, TX (United States); Enriquez, Erik [Univ. of Texas, San Antonio, TX (United States); Wang, Haibing [Univ. of Texas, San Antonio, TX (United States); Xu, Xing [Univ. of Texas, San Antonio, TX (United States); Bao, Shangyong [Univ. of Texas, San Antonio, TX (United States); Collins, Gregory [Univ. of Texas, San Antonio, TX (United States)

    2013-08-13

    The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo2O5+d (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

  4. Disposable amperometric magnetoimmunosensor for the sensitive detection of the cardiac biomarker amino-terminal pro-B-type natriuretic peptide in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Esteban-Fernández de Ávila, Berta, E-mail: berta.efa@quim.ucm.es; Escamilla-Gómez, Vanessa, E-mail: vaneeg@quim.ucm.es; Campuzano, Susana, E-mail: susanacr@quim.ucm.es; Pedrero, María, E-mail: mpedrero@quim.ucm.es; Pingarrón, José M., E-mail: pingarro@quim.ucm.es

    2013-06-19

    Graphical abstract: -- Highlights: •Novel and sensitive amperometric magnetoimmunosensor for NT-proBNP detection. •Indirect competitive immunoassay onto HOOC-MBs and Au/SPEs as transducers. •Excellent analytical performance at levels clinically relevant in human serum. •Useful in clinical diagnosis and prognosis of cardiac diseases. -- Abstract: A novel amperometric magnetoimmunosensor using an indirect competitive format is developed for the sensitive detection of the amino-terminal pro-B-type natriuretic peptide (NT-proBNP). The immunosensor design involves the covalent immobilization of the antigen onto carboxylic-modified magnetic beads (HOOC-MBs) activated with N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide (EDC) and N-hydroxysulfosuccinimide (sulfo-NHS), and further incubation in a mixture solution containing variable concentrations of the antigen and a fixed concentration of an HRP-labeled detection antibody. Accordingly, the target NT-proBNP in the sample and that immobilized on the MBs compete for binding to a fixed amount of the specific HRP-labeled secondary antibody. The immunoconjugate-bearing MBs are captured by a magnet placed under the surface of a disposable gold screen-printed electrode (Au/SPE). The amperometric responses measured at –0.10 V (vs. a Ag pseudo-reference electrode), upon addition of 3,3′,5,5′-tetramethylbenzidine (TMB) as electron transfer mediator and H{sub 2}O{sub 2} as the enzyme substrate, are used to monitor the affinity reaction. The developed magnetoimmunosensor provides attractive analytical characteristics in 10-times diluted human serum samples, exhibiting a linear range of clinical usefulness (0.12–42.9 ng mL{sup −1}) and a detection limit of 0.02 ng mL{sup −1}, which can be used in clinical diagnosis of chronic heart failure in the elderly and for classifying patients at risk of death after heart transplantation. The magnetoimmunosensor was successfully applied to the analysis of spiked human serum

  5. Effect of weekly high-dose vitamin D3 supplementation on serum cholecalciferol concentrations in pregnant women.

    Science.gov (United States)

    Dimitris, Michelle C; Perumal, Nandita; Craig-Barnes, Hayley A; Leadley, Michael; Mahmud, Abdullah A; Baqui, Abdullah H; Roth, Daniel E

    2016-04-01

    Vitamin D status is conventionally defined by the serum concentration of 25-hydroxyvitamin D. However, it has been proposed that the serum cholecalciferol concentration (D3) also determines functional vitamin D sufficiency. The objective of this study was to describe the effect of weekly high-dose vitamin D3 supplementation on inter-dose serum D3 in pregnant women. We conducted a sub-study of a completed randomized double-blind placebo-controlled trial of vitamin D3 (35,000 IU/week) supplementation in late pregnancy (AViDD trial) in Dhaka, Bangladesh. This study included pregnant women enrolled at 26-29 weeks gestation who fully adhered to the prenatal supplement intervention for ≥8 consecutive weeks and for whom serum samples were available for D3 analysis (n=65). Serum D3 was uniformly low at enrolment. Mean D3 increased and was maximal at 1 day after vitamin D dose administration (152.09nmol/L, SD 25.11nmol/L) and remained significantly higher in VitD vs. Pl at 7 days (29.59nmol/L vs. 1.92nmol/L, p=0.007). Daily average of the group mean D3 during the week following dosing was 66.97nmol/L in VitD versus 2.13nmol/L in Pl. In conclusion, serum D3 remained significantly elevated throughout the week following ≥8 consecutive weekly doses of 35,000 IU D3 in pregnant women. However, the clinically significant minimum threshold of serum D3 remains to be established. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    Science.gov (United States)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  7. High-dose vitamin B6 decreases homocysteine serum levels in patients with schizophrenia and schizoaffective disorders: a preliminary study.

    Science.gov (United States)

    Miodownik, Chanoch; Lerner, Vladimir; Vishne, Tali; Sela, Ben-Ami; Levine, Joseph

    2007-01-01

    Vitamin B6 plays an essential role in the normal functioning of the central nervous system. Normal homocysteine (Hcy) serum level is maintained by remethylation of Hcy to methionine by enzymes that require folic acid and vitamin B12 and by catabolism to cysteine by a vitamin B6-dependent enzyme. These findings may be consistent with the hypothesis that the vitamin B6 status may influence plasma Hcy levels. The aims of this preliminary study were (1) to determine whether a correlation exists between Hcy and vitamin B6 levels in patients with schizophrenia and schizoaffective disorders and (2) to investigate whether treatment with high-dose vitamin B6 may reduce Hcy levels in these patients. In this preliminary study, we enrolled 11 patients with schizophrenia or schizoaffective disorders (7 men and 4 women; mean age +/- SD, 50 +/- 12 years) receiving high doses of vitamin B6 treatment (1200 mg/d) for 12 weeks. Blood samples for the assessment of pyridoxal-5-phosphate and Hcy serum levels were obtained at baseline and after 12 weeks of treatment. Age was significantly positively correlated with Hcy levels at baseline (r = 0.392, P = 0.004). All other parameters, including diagnosis, disease duration, and pyridoxal-5-phosphate serum level, were not correlated with Hcy serum levels at baseline. After vitamin B6 treatment, Hcy serum levels significantly decreased (14.2 +/- 3.4 vs. 11.8 +/- 2.0 micromol/L, respectively, t = 2.679, P = 0.023); this decrease being statistically significant in men but not in women. High doses of vitamin B6 lead to a decrease in Hcy serum level in male patients with schizophrenia or schizoaffective disorder.

  8. SERUM LEVEL OF LIPIDS, APOLIPOPROTEINS AND VITAMIN D IN CHILDREN AT HIGH RISK OF CORONARY ARTERY DISEASE

    Directory of Open Access Journals (Sweden)

    M BASHTAM

    2002-06-01

    Full Text Available Introduction. Coronary artery disease (CAD is one of the most prevalent disease in human population that has high prevalence and mortality in lsfahan (Iran. As positive family history and changes in serum lipids and lipoproteins are risk factors of these diseases, and also studies have showed the relationship between serum vitamin D and CAD, we studied serum level of lipids, lipoproteins and vitamin D in high risk children compared with control group, and the relation between serum vitamin D and other factors. Methods. This case-control study was done on 44 subjects (25 boys, 19 girls aged 2-18 years old with positive CAD family history as case group and also 44 persons with negative CAD family history as control group with the same age groups. The subjects were selected by convenience sampling method. Children who consumed antiepilepthic drugs as phenytoin or phenobarbital and those who had positive family histroy for renal stone were excluded for variable vitamin D levels due to drug interaction and genetic susceptibility, respectively. All subjects were invited to Isfahan Cardiovascular Research Center. Using a questionnaire, information on personal characteristics, CVD family history and ... were obtained. A fasting (12-14 hr blood sample was drawn from each one. Serum APOA1, APO B100 and vitamin Dwere measured by radioimmunoassay and serum lipids by ELAN 2000 autoanalyzer. Statistical analysis was done by SPSS. The level of serum APOA1, APO B100 and vitamin D were compared between two groups by independent t test and the relation of the mentioned apolipoproteins with vitamin D was studied using multiple linear regression. Results. Serum vitamin D was significantly lower in case group (P < 0.045. Among studied factors, only triglyceride was significantly higher in control group (P < 0.0001 and also no significant relaitonship was observed between serum APO A1, APO B100 and vitamin D. Sex comparision in case group showed those mean levels

  9. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  10. Azithromycin blocks quorum sensing and alginate polymer formation and increases the sensitivity to serum and stationary growth phase killing of P. aeruginosa and attenuates chronic P. aeruginosa lung infection in Cftr -/--mice

    DEFF Research Database (Denmark)

    Hoffmann, N.; Lee, Bao le ri; Hentzer, Morten

    2007-01-01

    The consequences of O-acetylated alginate-producing Pseudomonas aeruginosa biofilms in the lungs of chronically infected cystic fibrosis (CF) patients are tolerance to both antibiotic treatments and effects on the innate and the adaptive defense mechanisms. In clinical trials, azithromycin (AZM...... and the complement system. Moreover, we show that AZM may affect the polymerization of P. aeruginosa alginate by the incomplete precipitation of polymerized alginate and high levels of readily dialyzable uronic acids. In addition, we find that mucoid bacteria in the stationary growth phase became sensitive to AZM......, whereas cells in the exponential phase did not. Interestingly, AZM-treated P. aeruginosa lasI mutants appeared to be particularly resistant to serum, whereas bacteria with a functional QS system did not. We show in a CF mouse model of chronic P. aeruginosa lung infection that AZM treatment results...

  11. Highly sensitive voltamperometric determination of pyritinol using carbon nanofiber/gold nanoparticle composite screen-printed carbon electrode

    Directory of Open Access Journals (Sweden)

    Apetrei IM

    2017-07-01

    Full Text Available Irina Mirela Apetrei,1 Constantin Apetrei2 1Department of Pharmaceutical Sciences, Medical and Pharmaceutical Research Center, Faculty of Medicine and Pharmacy, 2Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunarea de Jos” University of Galati, Galati, Romania Abstract: A novel and highly sensitive electrochemical method for the detection of pyritinol in pharmaceutical products and serum samples has been accomplished based on voltamperometric response of pyritinol in carbon nanofiber-gold nanoparticle (CNF-GNP-modified screen-printed carbon electrode (SPCE. The electrochemical response of pyritinol to CNF-GNP-modified SPCE was studied by cyclic voltammetry and square-wave voltammetry (SWV. Under optimized working conditions, the novel sensor shows excellent voltamperometric response toward pyritinol. The SWV study shows significantly enhanced electrochemical response for pyritinol in CNF-GNP-modified SPCE providing high sensitivity to the novel sensor for pyritinol detection. The peak current for pyritinol is found to be linear with the concentration in the range 1.0×10-8–5.0×10-5 M with a detection limit of 6.23×10-9 M using SWV as the detection method. The viability of the new developed sensor for the analytical purposes was studied by performing experiments on various commercial pharmaceutical products and blood serum samples, which yielded adequate recoveries of pyritinol. The novel electrochemical sensor provides high sensitivity, enhanced selectivity, good reproducibility and practical applicability. Keywords: pyritinol, carbon nanofiber, gold nanoparticle, sensor, square-wave voltammetry

  12. A comparison of osteoprotegerin with adiponectin and high-sensitivity C-reactive protein (hsCRP) as a marker for insulin resistance.

    LENUS (Irish Health Repository)

    O'Sullivan, Eoin P

    2013-01-01

    Insulin resistance (IR) is associated with low adiponectin and elevated high sensitivity C-reactive protein (hsCRP). Osteoprotegerin (OPG) has been shown to be elevated in type 2 diabetes, but whether it reflects underlying IR is unclear. We aimed to compare the ability of serum OPG with adiponectin and hsCRP to act as a marker for IR in individuals with normal and abnormal glucose tolerance.

  13. High-Density Lipoprotein Cholesterol, Blood Urea Nitrogen, and Serum Creatinine Can Predict Severe Acute Pancreatitis.

    Science.gov (United States)

    Hong, Wandong; Lin, Suhan; Zippi, Maddalena; Geng, Wujun; Stock, Simon; Zimmer, Vincent; Xu, Chunfang; Zhou, Mengtao

    2017-01-01

    Early prediction of disease severity of acute pancreatitis (AP) would be helpful for triaging patients to the appropriate level of care and intervention. The aim of the study was to develop a model able to predict Severe Acute Pancreatitis (SAP). A total of 647 patients with AP were enrolled. The demographic data, hematocrit, High-Density Lipoprotein Cholesterol (HDL-C) determinant at time of admission, Blood Urea Nitrogen (BUN), and serum creatinine (Scr) determinant at time of admission and 24 hrs after hospitalization were collected and analyzed statistically. Multivariate logistic regression indicated that HDL-C at admission and BUN and Scr at 24 hours (hrs) were independently associated with SAP. A logistic regression function (LR model) was developed to predict SAP as follows: -2.25-0.06 HDL-C (mg/dl) at admission + 0.06 BUN (mg/dl) at 24 hours + 0.66 Scr (mg/dl) at 24 hours. The optimism-corrected c-index for LR model was 0.832 after bootstrap validation. The area under the receiver operating characteristic curve for LR model for the prediction of SAP was 0.84. The LR model consists of HDL-C at admission and BUN and Scr at 24 hours, representing an additional tool to stratify patients at risk of SAP.

  14. Long term stability of paraoxonase-1 and high-density lipoprotein in human serum

    Directory of Open Access Journals (Sweden)

    Beekhof Piet K

    2012-05-01

    Full Text Available Abstract Background Paraoxonase-1 (PON1 is an enzyme with numerous functions and receives an increasing interest in clinical and epidemiological studies. Sometimes samples are stored for longer periods at a certain temperature. Therefore the stability of PON1 activity must be checked and retained upon storage for longer periods. Results In this study the stability of PON1 activity has been tested in human serum samples during storage up to 12 months at 3 commonly used temperatures, -20°C, -70°C and −196°C. It was found that the stability of the PON1 activity is constant during 12 months of storage at −70°C and −196°C. Storage at −20°C resulted in a small but statistically significant decrease after 6 months to about 94% of its original value. Nonetheless, the rank order between the samples at T = 0 and 12 months remained the same. The same temperature dependence was found for the associated high-density lipoprotein. Conclusions It can be concluded that −70°C is the right temperature for storage to maintain the PON1 activity for at least one year. Storage at a lower temperature in liquid nitrogen (−196°C is not necessary.

  15. Serum vitamin E concentrations among highly functioning hip fracture patients are higher than in nonfracture controls.

    Science.gov (United States)

    D'Adamo, Christopher R; Shardell, Michelle D; Hicks, Gregory E; Orwig, Denise L; Hochberg, Marc C; Semba, Richard D; Yu-Yahiro, Janet A; Ferrucci, Luigi; Magaziner, Jay S; Miller, Ram R

    2011-03-01

    Malnutrition after hip fracture is common and associated with poor outcomes and protracted recovery. Low concentrations of vitamin E have been associated with incident decline in physical function among older adults and may, therefore, be particularly important to functionally compromised patients hip fracture patients. Serum concentrations of α-tocopherol and γ-tocopherol, the 2 major forms of vitamin E, were assessed in 148 female hip fracture patients 65 years or older from the Baltimore Hip Studies cohort 4 around the time of fracture (baseline) and at 2, 6, and 12 month postfracture follow-up visits (recovery). It was hypothesized that mean concentrations of both forms of vitamin E among these hip fracture patients would be lowest at the baseline visit and increase at each study visit during the year after fracture. Linear regression and generalized estimating equations were used to assess changes in vitamin E concentrations after adjustment for covariates and to determine predictors of vitamin E concentrations at baseline and throughout recovery. It was also hypothesized that vitamin E concentrations shortly after hip fracture would be lower than those in nonfracture controls after adjustment for covariates. To evaluate this hypothesis, linear regression was used to perform adjusted comparisons of baseline vitamin E concentrations among Baltimore Hip Studies cohort 4 participants to 1076 older women without history of hip fracture from the Women's Health and Aging Study I, Invecchiare in Chianti Study, and the National Health and Nutrition Examination Surveys. Mean α-tocopherol was lowest at baseline, and time from fracture to blood draw was positively associated with baseline α-tocopherol (P = .005). Mean γ-tocopherol did not change appreciably throughout the year after fracture, although it fluctuated widely within individuals. Serum concentrations of α-tocopherol and γ-tocopherol were highest among the hip fracture population after adjustment (P hip

  16. High serum levels of YKL-40 in patients with squamous cell carcinoma of the head and neck are associated with short survival

    DEFF Research Database (Denmark)

    Roslind, A.; Johansen, J.S.; Christensen, L.J.

    2008-01-01

    by immunohistochemistry in 50 patients. Pretreatment serum YKL-40 was elevated in 53%. Patients with high serum YKL-40 had shorter survival than patients with normal serum YKL-40 (33 vs. 84 months; p = 0.008). Multivariate Cox analysis including pretreatment serum YKL-40, age, sex, primary tumor site, TNM classification...... and treatment demonstrated that TNM classification (HR = 2.61, p = 0.02) and serum YKL-40 (log-transformed continuous variable: HR = 1.55, p classification (HR = 5.77, p = 0.001) and serum...... YKL-40 (dichotomous variable: HR = 2.75, p = 0.01) were independent predictors of recurrence-free survival. During follow-up after radiotherapy, a high serum YKL-40 (log-transformed continuous variable) in patients with TNM Stage III and TV disease predicted poorer OS within 6 months (HR = 1.95, p

  17. Quantitation of bilirubin conjugates with high-performance liquid chromatography in patients with low total serum bilirubin levels

    NARCIS (Netherlands)

    Jansen, P. L.; Cuypers, H. T.; Peters, W. H.

    1984-01-01

    Bilirubin mono- and diconjugates were determined by alkaline methanolysis and high-performance liquid chromatography (HPLC) in serum from patients with metastatic liver disease and liver cirrhosis. Conjugates could be detected and quantitated at normal or low total bilirubin levels. Comparison with

  18. The preparation and properties of a highly specific antiserum elicited with 3-dehydrocholylglycine 3-succinyl-bovine serum albumin conjugate

    International Nuclear Information System (INIS)

    Orban, E.C.; Pal, Z.

    1986-01-01

    This report describes the synthesis of a new cholylglycine derivative-bovine serum albumin conjugate. The hapten is linked to the carrier protein at the C-3 position, through a hemisuccinate bridge. Antiserum elicited by this antigen is highly specific to cholylglycine. Cross-reactions with free cholic acid (less than 0.1%) or cholyltaurine (0.5%) are minimal. (author)

  19. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  20. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  1. Attenuating the mortality risk of high serum uric acid: the role of physical activity underused.

    Science.gov (United States)

    Chen, Jiunn-Horng; Wen, Chi Pang; Wu, Shiuan Bei; Lan, Joung-Liang; Tsai, Min Kuang; Tai, Ya-Ping; Lee, June Han; Hsu, Chih Cheng; Tsao, Chwen Keng; Wai, Jackson Pui Man; Chiang, Po Huang; Pan, Wen Han; Hsiung, Chao Agnes

    2015-11-01

    High serum uric acid (sUA) has been associated with increased mortality risks, but its clinical treatment varied with potential side effects. The role of physical activity has received limited attention. A cohort, consisting of 467 976 adults, who went through a standard health screening programme, with questionnaire and fasting blood samples, was successively recruited between 1996 and 2008. High sUA is defined as uric acid above 7.0 mg/dL. Leisure time physical activity level was self-reported, with fully active defined as those with 30 min per day for at least 5 days a week. National death file identified 12 228 deaths with a median follow-up of 8.5 years. Cox proportional model was used to analyse HRs, and 12 variables were controlled, including medical history, life style and risk factors. High sUA constituted one quarter of the cohort (25.6%). Their all-cause mortality was significantly increased [HR: 1.22 (1.15-1.29)], with much of the increase contributed to by the inactive (HR: 1.27 (1.17-1.37)), relative to the reference group with sUA level of 5-6 mg/dL. When they were fully active, mortality risks did not increase, but decreased by 11% (HR: 0.89 (0.82-0.97)), reflecting the benefits of being active was able to overcome the adverse effects of high sUA. Given the same high sUA, a 4-6 years difference in life expectancy was found between the active and the inactive. Physical activity is a valuable alternative to pharmacotherapy in its ability to reduce the increases in mortality risks from high sUA. By being fully active, exercise can extend life span by 4-6 years, a level greater than the 1-4 years of life-shortening effect from high sUA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Desensitization protocol in highly HLA-sensitized and ABO-incompatible high titer kidney transplantation.

    Science.gov (United States)

    Uchida, J; Machida, Y; Iwai, T; Naganuma, T; Kitamoto, K; Iguchi, T; Maeda, S; Kamada, Y; Kuwabara, N; Kim, T; Nakatani, T

    2010-12-01

    A positive crossmatch indicates the presence of donor-specific alloantibodies and is associated with a graft loss rate of >80%; anti-ABO blood group antibodies develop in response to exposure to foreign blood groups, resulting in immediate graft loss. However, a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation has not yet been established. We treated 6 patients with high (≥1:512) anti-A/B antibody titers and 2 highly HLA-sensitized patients. Our immunosuppression protocol was initiated 1 month before surgery and included mycophenolate mofetil (1 g/d) and/or low-dose steroid (methylprednisolone 8 mg/d). Two doses of the anti-CD20 antibody rituximab (150 mg/m(2)) were administered 2 weeks before and on the day of transplantation. We performed antibody removal with 6-12 sessions of plasmapheresis (plasma exchange or double-filtration plasmapheresis) before transplantation. Splenectomy was also performed on the day of transplantation. Postoperative immunosuppression followed the same regimen as ABO-compatible cases, in which calcineurin inhibitors were initiated 3 days before transplantation, combined with 2 doses of basiliximab. Of the 8 patients, 7 subsequently underwent successful living-donor kidney transplantation. Follow-up of our recipients showed that the patient and graft survival rates were 100%. Acute cellular rejection and antibody-mediated rejection episodes occurred in 1 of the 7 recipients. These findings suggest that our immunosuppression regimen consisting of rituximab infusions, splenectomy, plasmapheresis, and pharmacologic immunosuppression may prove to be effective as a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  4. Highly Sensitive Cadmium Concentration Sensor Using Long Period Grating

    Directory of Open Access Journals (Sweden)

    A. S. Lalasangi

    2011-08-01

    Full Text Available In this paper we have proposed a simple and effective Long Period Grating chemical sensor for detecting the traces of Cadmium (Cd++ in drinking water at ppm level. Long Period gratings (LPG were fabricated by point-by-point technique with CO2 laser. We have characterized the LPG concentration sensor sensitivity for different solutions of Cd concentrations varying from 0.01 ppm to 0.04 ppm by injecting white Light source and observed transmitted spectra using Optical Spectrum Analyzer (OSA. Proper reagents have been used in the solutions for detection of the Cd species. The overall shift in wavelength is 10 nm when surrounding medium gradually changed from water to 0.04 ppm of cadmium concentrations. A comparative study has been done using sophisticated spectroscopic atomic absorption spectrometer (AAS and Inductively Coupled Plasma (ICP instruments. The spectral sensitivity enhancement was done by modifying grating surface with gold nanoparticles.

  5. Highly sensitive BTX detection using surface functionalized QCM sensor

    Energy Technology Data Exchange (ETDEWEB)

    Bozkurt, Asuman Aşıkoğlu; Özdemir, Okan; Altındal, Ahmet, E-mail: altindal@yildiz.edu.tr [Department of Physics, Yildiz Technical University, Davutpasa, 34210 Istanbul (Turkey)

    2016-03-25

    A novel organic compound was designed and successfully synthesized for the fabrication of QCM based sensors to detect the low concentrations of BTX gases in indoor air. The effect of the long-range electron orbital delocalization on the BTX vapour sensing properties of azo-bridged Pcs based chemiresistor-type sensors have also been investigated in this work. The sensing behaviour of the film for the online detection of volatile organic solvent vapors was investigated by utilizing an AT-cut quartz crystal resonator. It was observed that the adsorption of the target molecules on the coating surface cause a reversible negative frequency shift of the resonator. Thus, a variety of solvent vapors can be detected by using the phthalocyanine film as sensitive coating, with sensitivity in the ppm range and response times in the order of several seconds depending on the molecular structure of the organic solvent.

  6. Antibody Desensitization Therapy in Highly Sensitized Lung Transplant Candidates

    Science.gov (United States)

    Snyder, L. D.; Gray, A. L.; Reynolds, J. M.; Arepally, G. M.; Bedoya, A.; Hartwig, M. G.; Davis, R. D.; Lopes, K. E.; Wegner, W. E.; Chen, D. F.; Palmer, S. M.

    2015-01-01

    As HLAs antibody detection technology has evolved, there is now detailed HLA antibody information available on prospective transplant recipients. Determining single antigen antibody specificity allows for a calculated panel reactive antibodies (cPRA) value, providing an estimate of the effective donor pool. For broadly sensitized lung transplant candidates (cPRA ≥ 80%), our center adopted a pretransplant multimodal desensitization protocol in an effort to decrease the cPRA and expand the donor pool. This desensitization protocol included plasmapheresis, solumedrol, bortezomib and rituximab given in combination over 19 days followed by intravenous immunoglobulin. Eight of 18 candidates completed therapy with the primary reasons for early discontinuation being transplant (by avoiding unacceptable antigens) or thrombocytopenia. In a mixed-model analysis, there were no significant changes in PRA or cPRA changes over time with the protocol. A sub-analysis of the median fluorescence intensity (MFI) change indicated a small decline that was significant in antibodies with MFI 5000–10 000. Nine of 18 candidates subsequently had a transplant. Posttransplant survival in these nine recipients was comparable to other pretransplant-sensitized recipients who did not receive therapy. In summary, an aggressive multi-modal desensitization protocol does not significantly reduce pretransplant HLA antibodies in a broadly sensitized lung transplant candidate cohort. PMID:24666831

  7. A High-Sensitivity Current Sensor Utilizing CrNi Wire and Microfiber Coils

    Directory of Open Access Journals (Sweden)

    Xiaodong Xie

    2014-05-01

    Full Text Available We obtain an extremely high current sensitivity by wrapping a section of microfiber on a thin-diameter chromium-nickel wire. Our detected current sensitivity is as high as 220.65 nm/A2 for a structure length of only 35 μm. Such sensitivity is two orders of magnitude higher than the counterparts reported in the literature. Analysis shows that a higher resistivity or/and a thinner diameter of the metal wire may produce higher sensitivity. The effects of varying the structure parameters on sensitivity are discussed. The presented structure has potential for low-current sensing or highly electrically-tunable filtering applications.

  8. Effect of high hydrostatic pressure on the enzymatic hydrolysis of bovine serum albumin.

    Science.gov (United States)

    De Maria, Serena; Ferrari, Giovanna; Maresca, Paola

    2017-08-01

    The extent of enzymatic proteolysis mainly depends on accessibility of the peptide bonds, which stabilize the protein structure. The high hydrostatic pressure (HHP) process is able to induce, at certain operating conditions, protein displacement, thus suggesting that this technology can be used to modify protein resistance to the enzymatic attack. This work aims at investigating the mechanism of enzymatic hydrolysis assisted by HHP performed under different processing conditions (pressure level, treatment time). Bovine serum albumin was selected for the experiments, solubilized in sodium phosphate buffer (25 mg mL -1 , pH 7.5) with α-chymotrypsin or trypsin (E/S ratio = 1/10) and HPP treatment (100-500 MPa, 15-25 min). HHP treatment enhanced the extent of the hydrolysis reaction of globular proteins, being more effective than conventional hydrolysis. At HHP treatment conditions maximizing the protein unfolding, the hydrolysis degree of proteins was increased as a consequence of the increased exposure of peptide bonds to the attack of proteolytic enzymes. The maximum hydrolysis degree (10% and 7% respectively for the samples hydrolyzed with α-chymotrypsin and trypsin) was observed for the samples processed at 400 MPa for 25 min. At pressure levels higher than 400 MPa the formation of aggregates was likely to occur; thus the degree of hydrolysis decreased. Protein unfolding represents the key factor controlling the efficiency of HHP-assisted hydrolysis treatments. The peptide produced under high pressure showed lower dimensions and a different structure with respect to those of the hydrolysates obtained when the hydrolysis was carried out at atmospheric pressure, thus opening new frontiers of application in food science and nutrition. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  9. High-resolution, high-sensitivity NMR of nano-litre anisotropic samples by coil spinning

    Energy Technology Data Exchange (ETDEWEB)

    Sakellariou, D [CEA Saclay, DSM, DRECAM, SCM, Lab Struct and Dynam Resonance Magnet, CNRS URA 331, F-91191 Gif Sur Yvette, (France); Le Goff, G; Jacquinot, J F [CEA Saclay, DSM, DRECAM, SPEC: Serv Phys Etat Condense, CNRS URA 2464, F-91191 Gif Sur Yvette, (France)

    2007-07-01

    Nuclear magnetic resonance (NMR) can probe the local structure and dynamic properties of liquids and solids, making it one of the most powerful and versatile analytical methods available today. However, its intrinsically low sensitivity precludes NMR analysis of very small samples - as frequently used when studying isotopically labelled biological molecules or advanced materials, or as preferred when conducting high-throughput screening of biological samples or 'lab-on-a-chip' studies. The sensitivity of NMR has been improved by using static micro-coils, alternative detection schemes and pre-polarization approaches. But these strategies cannot be easily used in NMR experiments involving the fast sample spinning essential for obtaining well-resolved spectra from non-liquid samples. Here we demonstrate that inductive coupling allows wireless transmission of radio-frequency pulses and the reception of NMR signals under fast spinning of both detector coil and sample. This enables NMR measurements characterized by an optimal filling factor, very high radio-frequency field amplitudes and enhanced sensitivity that increases with decreasing sample volume. Signals obtained for nano-litre-sized samples of organic powders and biological tissue increase by almost one order of magnitude (or, equivalently, are acquired two orders of magnitude faster), compared to standard NMR measurements. Our approach also offers optimal sensitivity when studying samples that need to be confined inside multiple safety barriers, such as radioactive materials. In principle, the co-rotation of a micrometer-sized detector coil with the sample and the use of inductive coupling (techniques that are at the heart of our method) should enable highly sensitive NMR measurements on any mass-limited sample that requires fast mechanical rotation to obtain well-resolved spectra. The method is easy to implement on a commercial NMR set-up and exhibits improved performance with miniaturization, and we

  10. REG4 Is Highly Expressed in Mucinous Ovarian Cancer: A Potential Novel Serum Biomarker.

    Directory of Open Access Journals (Sweden)

    Laura Lehtinen

    Full Text Available Preoperative diagnostics of ovarian neoplasms rely on ultrasound imaging and the serum biomarkers CA125 and HE4. However, these markers may be elevated in non-neoplastic conditions and may fail to identify most non-serous epithelial cancer subtypes. The objective of this study was to identify histotype-specific serum biomarkers for mucinous ovarian cancer. The candidate genes with mucinous histotype specific expression profile were identified from publicly available gene-expression databases and further in silico data mining was performed utilizing the MediSapiens database. Candidate biomarker validation was done using qRT-PCR, western blotting and immunohistochemical staining of tumor tissue microarrays. The expression level of the candidate gene in serum was compared to the serum CA125 and HE4 levels in a patient cohort of prospectively collected advanced ovarian cancer. Database searches identified REG4 as a potential biomarker with specificity for the mucinous ovarian cancer subtype. The specific expression within epithelial ovarian tumors was further confirmed by mRNA analysis. Immunohistochemical staining of ovarian tumor tissue arrays showed distinctive cytoplasmic expression pattern only in mucinous carcinomas and suggested differential expression between benign and malignant mucinous neoplasms. Finally, an ELISA based serum biomarker assay demonstrated increased expression only in patients with mucinous ovarian cancer. This study identifies REG4 as a potential serum biomarker for histotype-specific detection of mucinous ovarian cancer and suggests serum REG4 measurement as a non-invasive diagnostic tool for postoperative follow-up of patients with mucinous ovarian cancer.

  11. Determination of 17-oxosteroid glucuronides and sulfates in urine and serum by fluorescence high-performance liquid chromatography using dansyl hydrazine as a prelabeling reagent.

    Science.gov (United States)

    Kawasaki, T; Maeda, M; Tsuji, A

    1982-12-10

    A fluorescence high-performance liquid chromatographic method is described for the direct determination of conjugated 17-oxosteroids in biological fluids without hydrolysis. Conjugated 17-oxosteroids are extracted with Sep-Pak C18 cartridge, labeled with dansyl hydrazine in trichloroacetic acid--benzene solution and then separated by high-performance liquid chromatography on reversed-phase muBondapak C18 column using 0.01 M sodium acetate in methanol-water-acetic acid (65:35:1, v/v) as the mobile phase. The eluate is monitored by a fluorophotometer at 365 nm (excitation) and 520 nm (emission). Linearities of fluorescence intensities (peak heights) with the amounts of various conjugated 17-oxosteroids were obtained between 10 pmol and 100 pmol. This method is sensitive, reliable and useful for the simultaneous determination of conjugated 17-oxosteroids in urine and serum.

  12. From Molecular Design to Co-sensitization; High performance indole based photosensitizers for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Babu, Dickson D.; Su, Rui; El-Shafei, Ahmed; Adhikari, Airody Vasudeva

    2016-01-01

    displays promising photovoltaic results and exhibited an enhanced efficiency of 8.06%. Further, good agreement between the calculated and experimental results showcase the precision of the energy functional and basis set utilized in this study. All these findings provide a deeper insight and better understanding into the intricacies involved in the design of superior co-sensitizers for development of highly efficient DSSCs.

  13. New approach to 3-D, high sensitivity, high mass resolution space plasma composition measurements

    International Nuclear Information System (INIS)

    McComas, D.J.; Nordholt, J.E.

    1990-01-01

    This paper describes a new type of 3-D space plasma composition analyzer. The design combines high sensitivity, high mass resolution measurements with somewhat lower mass resolution but even higher sensitivity measurements in a single compact and robust design. While the lower resolution plasma measurements are achieved using conventional straight-through time-of-flight mass spectrometry, the high mass resolution measurements are made by timing ions reflected in a linear electric field (LEF), where the restoring force that an ion experiences is proportional to the depth it travels into the LEF region. Consequently, the ion's equation of motion in that dimension is that of a simple harmonic oscillator and its travel time is simply proportional to the square root of the ion's mass/charge (m/q). While in an ideal LEF, the m/q resolution can be arbitrarily high, in a real device the resolution is limited by the field linearity which can be achieved. In this paper we describe how a nearly linear field can be produced and discuss how the design can be optimized for various different plasma regimes and spacecraft configurations

  14. Optofluidic ring resonator sensor for sensitive label-free detection of breast cancer antigen CA15-3 in human serum

    Science.gov (United States)

    Zhu, Hongying; Dale, Paul S.; Fan, Xudong

    2009-05-01

    Breast cancer is the most frequently diagnosed malignancy in women worldwide. Because of its great impact on society, a lot of research funding has been used to develop novel detection tools for aiding breast cancer diagnosis and prognosis. In this work, we demonstrated a simple, fast, and sensitive detection of circulating breast cancer biomarker CA15-3 with opto-fluidic ring resonator (OFRR) sensors. The OFRR sensor employs a thin-walled capillary with wall thickness less than 4 μm. The circular cross section of the capillary forms the optical ring resonator, in which the light circulates in the form of whispering gallery modes (WGMs). The capillary wall is thin enough that the evanescent field of the WGM extends into the capillary core and responds to refractive index changes in the capillary core or close to its interior surface. The WGM spectral position will change when the biomolecules bind to the surface, yielding quantitative and kinetic information about the biomolecule interaction. Here, the direct immunoassay method was employed for the detection of CA15-3 antigen without any signal amplification steps. The sensor performance in both PBS buffer and human serum were investigated, respectively. The experimental detection limit was 5 units/mL in PBS buffer and 30 units/mL for CA15-3 spiked in serum, both of which satisfied clinical diagnosis requirements. The potential use of the OFRR as the point-of-care device for breast cancer detection was tested by measuring the CA15-3 level in blood samples collected from stage IV breast cancer patients and the results were compared with standard clinical test.

  15. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Andersen, Thomas; Jensen, Robert; Christensen, M. K.

    2012-01-01

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal...

  16. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    Science.gov (United States)

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  17. The Relationship between Ethical Sensitivity, High Ability and Gender in Higher Education Students

    Science.gov (United States)

    Schutte, Ingrid; Wolfensberger, Marca; Tirri, Kirsi

    2014-01-01

    This study examined the ethical sensitivity of high-ability undergraduate students (n=731) in the Netherlands who completed the 28-item Ethical Sensitivity Scale Questionnaire (ESSQ) developed by Tirri & Nokelainen (2007; 2011). The ESSQ is based on Narvaez' (2001) operationalization of ethical sensitivity in seven dimensions. The following…

  18. Platinum decorated carbon nanotubes for highly sensitive amperometric glucose sensing

    International Nuclear Information System (INIS)

    Xie Jining; Wang Shouyan; Aryasomayajula, L; Varadan, V K

    2007-01-01

    Fine platinum nanoparticles (1-5 nm in diameter) were deposited on functionalized multi-walled carbon nanotubes (MWNTs) through a decoration technique. A novel type of enzymatic Pt/MWNTs paste-based mediated glucose sensor was fabricated. Electrochemical measurements revealed a significantly improved sensitivity (around 52.7 μA mM -1 cm -2 ) for glucose sensing without using any picoampere booster or Faraday cage. In addition, the calibration curve exhibited a good linearity in the range of 1-28 mM of glucose concentration. Transmission electron microscopy (TEM) and x-ray photoelectron spectroscopy (XPS) were performed to investigate the nanoscale structure and the chemical bonding information of the Pt/MWNTs paste-based sensing material, respectively. The improved sensitivity of this novel glucose sensor could be ascribed to its higher electroactive surface area, enhanced electron transfer, efficient enzyme immobilization, unique interaction in nanoscale and a synergistic effect on the current signal from possible multi-redox reactions

  19. High Sensitivity TSS Prediction: Estimates of Locations Where TSS Cannot Occur

    KAUST Repository

    Schaefer, Ulf; Kodzius, Rimantas; Kai, Chikatoshi; Kawai, Jun; Carninci, Piero; Hayashizaki, Yoshihide; Bajic, Vladimir B.

    2013-01-01

    from mouse and human genomes, we developed a methodology that allows us, by performing computational TSS prediction with very high sensitivity, to annotate, with a high accuracy in a strand specific manner, locations of mammalian genomes that are highly

  20. Mangiferin binding to serum albumin is non-saturable and induces conformational changes at high concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, P.G.; Barbosa, A.F. [Biochemistry Laboratory, Institute of Exact Sciences, Federal University of Alfenas, Unifal-MG, R. Gabriel Monteiro da Silva, 700, 37130-000 Alfenas, MG (Brazil); Saraiva, L.A. [Phytochemistry and Medicinal Chemistry Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Camps, I. [Physics Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Silveira, N.J.F. da [Bioinformatics Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Veloso, M.P. [Phytochemistry and Medicinal Chemistry Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Santos, M.H., E-mail: poliany.santos@gmail.com [Phytochemistry and Medicinal Chemistry Laboratory, Institute of Exact Sciences, Unifal-MG (Brazil); Schneedorf, J.M., E-mail: zemasfs@gmail.com [Biochemistry Laboratory, Institute of Exact Sciences, Federal University of Alfenas, Unifal-MG, R. Gabriel Monteiro da Silva, 700, 37130-000 Alfenas, MG (Brazil)

    2012-11-15

    The binding interaction between mangiferin (MGF), which a natural xanthone isolated from mangoes, and bovine serum albumin (BSA) was studied with absorbance and fluorescence spectroscopy, cyclic voltammetry and molecular modeling. The data were analyzed to assess the binding mechanism, effect of pH and ionic strength, conformational changes in the protein and electrical charge transfer involved. The MGF-BSA complex exhibited positive cooperativity with a 1:1 stoichiometry (K{sub d}=0.38 mmol L{sup -1}) for the first binding site and a non-saturable binding at high ligand concentrations. Furthermore, the data also suggest an increase in drug bioavailability in the acidic region and relatively low ionic strength values, which are close to physiological levels. The data suggest a specific electrostatic interaction together with hydrophobic effects and H-bonding displayed in MGF binding to the BSA IIA subdomain. Synchronous fluorescence spectra indicate that there are conformational changes in the polypeptide backbone upon ligand binding. Cyclic voltammetry indicates that there is an irreversible charge transfer between MGF and BSA that is modulated by diffusion on the electrode surface, where two electrons are transferred. These results can help the knowledge of the pharmacokinetic activities of natural or chemical xanthone-based drugs. - Highlights: Black-Right-Pointing-Pointer The MGF-BSA complex exhibited positive cooperativity beyond 1:1 stoichiometry. Black-Right-Pointing-Pointer The interaction of MGF with BSA is non-saturable at higher ligand concentration. Black-Right-Pointing-Pointer The binding was accomplished by H-bonding, hydrophobic and electrostatic forces. Black-Right-Pointing-Pointer The apparent binding constant for MGF-BSA was 0.38 mmol L{sup -1}. Black-Right-Pointing-Pointer MGF binds electrostatically to BSA, different from a hydrophobic interaction to HSA.

  1. Molecular epidemiology of malaria in Cameroon. XV. Experimental studies on serum substitutes and supplements and alternative culture media for in vitro drug sensitivity assays using fresh isolates of Plasmodium falciparum.

    Science.gov (United States)

    Basco, Leonardo K

    2003-08-01

    In vitro drug sensitivity assay is an important tool for various on-going studies aiming to establish the correlation between candidate molecular markers for drug resistance and drug response in laboratory-adapted strains and field isolates of Plasmodium falciparum. A widespread use of this technique in the field would require a suitable substitute that can replace human serum. In this study, several alternative sources of serum substitutes and supplements were evaluated for their capacity to sustain parasite growth for a single life cycle and their compatibility with in vitro assays for clinical isolates that have not been adapted to in vitro culture. Albumax, a commercial preparation of lipid-enriched bovine albumin, did not support parasite growth as much as human serum and fetal calf serum in several isolates. Other serum supplements (AmnioMax and Ultroser) supported parasite growth relatively well. The 50% inhibitory concentrations (IC50s) of chloroquine and antifolates determined with 0.05% Albumax were generally two or three times higher than with human serum. With 10% fetal calf serum, IC50s for chloroquine and antifolates were approximately two times higher and three times lower than with human serum, respectively. The use of AmnioMax and OptiMAb resulted in a greater than two-fold increase in IC50s and several uninterpretable assays. Despite possible batch-to-batch differences, fetal calf serum may be a suitable substitute for in vitro drug assays while awaiting the results of further studies on other serum substitutes and supplements.

  2. High YKL-40 serum concentration is correlated with prognosis of Chinese patients with breast cancer.

    Directory of Open Access Journals (Sweden)

    Dong Wang

    Full Text Available This study aimed to investigate the association between serum YKL-40 and prognosis of breast cancer in a Chinese population. Expression of YKL-40 of 120 Chinese patients with breast cancer and 30 controls (benign breast lesions was measured in tumor tissue by immunohistochemistry and in serum by ELISA. Differences in YKL-40 positivity grouped by specific patients' characteristics were compared using Pearson Chi-square test for rates of intratumoral staining, one-way ANOVA with a Bonferroni post-hoc comparison, or two-sample t-test for mean YKL-40 serum concentrations. Factors associated with overall survival were identified by univariate and multivariate cox-regression analyses. YKL-40 was elevated in approximately 75% of Chinese patients with breast cancer. A significantly higher percentage of patients with YKL-40 positive tumors had larger tumor size, higher TNM stage, and/or lymph node metastasis. Significantly higher mean YKL-40 serum concentrations were observed in patient subgroups with invasive lobular carcinoma (P<0.0167, higher TNM stage (P<0.001, and positive lymph node metastasis (P<0.001. The estimated mean survival time of patients with YKL-40 positive tumors was significantly shorter than for patients with YKL-40 negative tumors (55.13 months vs 65.78 months, P = 0.017. Multivariable Cox-regression analysis identified a significant association of overall survival time with YKL-40 serum concentration. Patients with YKL-40 positive tumors had significantly shorter disease free survival times than those with YKL-40 negative tumors. We propose that the potential utility of YKL-40 intratumoral staining or serum concentration as a biomarker for breast cancer is greatest within 5 years of diagnosis.

  3. Characterization of the serum metabolome following radiation treatment in patients with high-grade gliomas

    International Nuclear Information System (INIS)

    Mörén, Lina; Wibom, Carl; Bergström, Per; Johansson, Mikael; Antti, Henrik; Bergenheim, A. Tommy

    2016-01-01

    Glioblastomas progress rapidly making response evaluation using MRI insufficient since treatment effects are not detectable until months after initiation of treatment. Thus, there is a strong need for supplementary biomarkers that could provide reliable and early assessment of treatment efficacy. Analysis of alterations in the metabolome may be a source for identification of new biomarker patterns harboring predictive information. Ideally, the biomarkers should be found within an easily accessible compartment such as the blood. Using gas-chromatographic- time-of-flight-mass spectroscopy we have analyzed serum samples from 11 patients with glioblastoma during the initial phase of radiotherapy. Fasting serum samples were collected at admittance, on the same day as, but before first treatment and in the morning after the second and fifth dose of radiation. The acquired data was analyzed and evaluated by chemometrics based bioinformatics methods. Our findings were compared and discussed in relation to previous data from microdialysis in tumor tissue, i.e. the extracellular compartment, from the same patients. We found a significant change in metabolite pattern in serum comparing samples taken before radiotherapy to samples taken during early radiotherapy. In all, 68 metabolites were lowered in concentration following treatment while 16 metabolites were elevated in concentration. All detected and identified amino acids and fatty acids together with myo-inositol, creatinine, and urea were among the metabolites that decreased in concentration during treatment, while citric acid was among the metabolites that increased in concentration. Furthermore, when comparing results from the serum analysis with findings in tumor extracellular fluid we found a common change in metabolite patterns in both compartments on an individual patient level. On an individual metabolite level similar changes in ornithine, tyrosine and urea were detected. However, in serum, glutamine and

  4. Highly sensitive urea sensing with ion-irradiated polymer foils

    International Nuclear Information System (INIS)

    Fink, Dietmar; Muñoz Hernandez, Gerardo; Alfonta, Lital

    2012-01-01

    Recently we prepared urea-sensors by attaching urease to the inner walls of etched ion tracks within thin polymer foil. Here, alternative track-based sensor configurations are examined where the enzyme remained in solution. The conductivities of systems consisting of two parallel irradiated polymer foils and confining different urea/urease mixtures in between were examined. The correlations between conductivity and urea concentration differed strongly for foils with unetched and etched tracks, which points at different sensing mechanisms – tentatively attributed to the adsorption of enzymatic reaction products on the latent track entrances and to the enhanced conductivity of reaction product-filled etched tracks, respectively. All examined systems enable in principle, urea sensing. They point at the possibility of sensor cascade construction for more sensitive or selective sensor systems.

  5. A new compact, high sensitivity neutron imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Caillaud, T.; Landoas, O.; Briat, M.; Rosse, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L. [CEA, DAM, DIF,F-91297 Arpajon (France); Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States); Park, H. S.; Robey, H. F.; Amendt, P. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

  6. A new compact, high sensitivity neutron imaging system

    International Nuclear Information System (INIS)

    Caillaud, T.; Landoas, O.; Briat, M.; Rossé, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L.; Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C.; Park, H. S.; Robey, H. F.; Amendt, P.

    2012-01-01

    We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10 9 –10 10 neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 × 10 10 . The resolution of this image was 54 μm and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a 60 Co γ-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

  7. Design and synthesis of new fluorescent probe for rapid and highly sensitive detection of proteins via electrophoretic gel stain.

    Science.gov (United States)

    Suzuki, Yoshio; Takagi, Nobuyuki; Chimuro, Tomoyuki; Shinohara, Atsushi; Sakaguchi, Nao; Hiratsuka, Atsunori; Yokoyama, Kenji

    2011-06-01

    A new fluorescent molecular probe, 2,2'-(1E,1'E)-2,2'-(4-(dicyanomethylene)-4H-pyrane-2,6-diyl)bis(ethene-2,1-diyl)bis(sodium benzenesulfonate) salt (1), possessing the cyanopyranyl moieties and two benzene sulfonic acid groups was designed and synthesized to detect proteins in solution and for high-throughput SDS-PAGE. Compound 1 exhibited no fluorescence in the absence of proteins; however, it exhibited strong fluorescence on the addition of bovine serum albumin as a result of intramolecular charge transfer. Compared with the conventional protocols for in-gel protein staining, such as SYPRO Ruby and silver staining, 1 achieves higher sensitivity, even though it offers a simplified, higher throughput protocol. In fact, the total time required for protein staining was 60-90 min under optimum conditions much shorter than that required by the less-sensitive silver staining or SYPRO Ruby staining protocols. Moreover, 1 was successfully applied to protein identification by mass spectrometry via in-gel tryptic digestion, Western blotting, and native PAGE together with protein staining by 1, which is a modified protocol of blue native PAGE (BN-PAGE). Thus, 1 may facilitate high-sensitivity protein detection, and it may be widely applicable as a convenient tool in various scientific and medical fields. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Serum galactomannan screening for diagnosis of invasive pulmonary aspergillosis in children after stem cell transplantation or with high-risk leukemia.

    Science.gov (United States)

    Gefen, Aharon; Zaidman, Irina; Shachor-Meyouhas, Yael; Avidor, Israela; Hakim, Fahed; Weyl Ben-Arush, Myriam; Kassis, Imad

    2015-03-01

    Both transplanted and leukemia patients are at high risk (HR) for invasive pulmonary aspergillosis (IPA). Methods for rapid diagnosis are crucial. Our objective was to investigate the impact of serial serum galactomannan assay (GMA) screening on IPA diagnosis in children. Between January 2010 and December 2011, all children following stem cell transplantation (SCT) or with HR leukemia were prospectively included. Serum samples for GMA were taken once-twice weekly. Results >.5 were considered positive. Patients suspected of having IPA were stratified as possible, probable, and definite. Forty-six children (median age, 8 years) were included, 38 after SCT (32 allogeneic), 8 with HR leukemia. A total of 510 samples were taken; screening period was 1-6 months for 34 patients. GMA was negative in 28 patients, all but one without suspicion of IPA. Eighteen patients had positive GMA: while four (22%) were upgraded to probable IPA, fourteen (78%) were considered as false positives (FP), some associated with piperacillin-tazobactam treatment. GMA sensitivity and specificity were 0.8 and 0.66, respectively; positive- and negative-predictive values (PPV, NPV) were 0.22 and 0.96, respectively. GMA may have a role in evaluating HR children for IPA. Both NPV and FP rates are high. The cost benefit of early detection versus over-diagnosis should be further studied.

  9. High Plasma TIMP-1 and Serum CEA Levels during Combination Chemotherapy for Metastatic Colorectal Cancer Are Significantly Associated with Poor Outcome

    DEFF Research Database (Denmark)

    Aldulaymi, Bahir; Byström, Per; Berglund, Ake

    2010-01-01

    . The first response evaluation was performed after 8 weeks of chemotherapy. Results: Median plasma TIMP-1 and serum CEA levels did not change significantly during 6 weeks of treatment. High plasma TIMP-1 and high serum CEA levels before treatment and at weeks 2, 4 and 6 were related to poor objective...... associated with poor overall survival; p

  10. High fat diet-fed obese rats are highly sensitive to doxorubicin-induced cardiotoxicity

    International Nuclear Information System (INIS)

    Mitra, Mayurranjan S.; Donthamsetty, Shashikiran; White, Brent; Mehendale, Harihara M.

    2008-01-01

    Often, chemotherapy by doxorubicin (Adriamycin) is limited due to life threatening cardiotoxicity in patients during and posttherapy. Recently, we have shown that moderate diet restriction remarkably protects against doxorubicin-induced cardiotoxicity. This cardioprotection is accompanied by decreased cardiac oxidative stress and triglycerides and increased cardiac fatty-acid oxidation, ATP synthesis, and upregulated JAK/STAT3 pathway. In the current study, we investigated whether a physiological intervention by feeding 40% high fat diet (HFD), which induces obesity in male Sprague-Dawley rats (250-275 g), sensitizes to doxorubicin-induced cardiotoxicity. A LD 10 dose (8 mg doxorubicin/kg, ip) administered on day 43 of the HFD feeding regimen led to higher cardiotoxicity, cardiac dysfunction, lipid peroxidation, and 80% mortality in the obese (OB) rats in the absence of any significant renal or hepatic toxicity. Doxorubicin toxicokinetics studies revealed no change in accumulation of doxorubicin and doxorubicinol (toxic metabolite) in the normal diet-fed (ND) and OB hearts. Mechanistic studies revealed that OB rats are sensitized due to: (1) higher oxyradical stress leading to upregulation of uncoupling proteins 2 and 3, (2) downregulation of cardiac peroxisome proliferators activated receptor-α, (3) decreased plasma adiponectin levels, (4) decreased cardiac fatty-acid oxidation (666.9 ± 14.0 nmol/min/g heart in ND versus 400.2 ± 11.8 nmol/min/g heart in OB), (5) decreased mitochondrial AMP-α2 protein kinase, and (6) 86% drop in cardiac ATP levels accompanied by decreased ATP/ADP ratio after doxorubicin administration. Decreased cardiac erythropoietin and increased SOCS3 further downregulated the cardioprotective JAK/STAT3 pathway. In conclusion, HFD-induced obese rats are highly sensitized to doxorubicin-induced cardiotoxicity by substantially downregulating cardiac mitochondrial ATP generation, increasing oxidative stress and downregulating the JAK/STAT3

  11. High serum levels of YKL-40 in patients with systemic sclerosis are associated with pulmonary involvement

    DEFF Research Database (Denmark)

    Nordenbaek, C; Johansen, J S; Halberg, P

    2005-01-01

    OBJECTIVES: YKL-40, a growth factor of connective tissue cells, is elevated in sera from patients with diseases characterized by inflammation, tissue remodelling, or fibrosis. The aim of the study was to determine serum YKL-40 levels in patients with systemic sclerosis (SSc) and to explore any po...

  12. Highly Specific Detection of Myostatin Prodomain by an Immunoradiometric Sandwich Assay in Serum of Healthy Individuals and Patients

    Science.gov (United States)

    Widera, Christian; Gottlieb, Jens; Vogel, Arndt; Schmidt, Sebastian; Brandes, Gudrun; Heuft, Hans-Gert; Lichtinghagen, Ralf; Kempf, Tibor; Wollert, Kai C.; Bauersachs, Johann; Heineke, Joerg

    2013-01-01

    Background Myostatin is a muscle derived factor that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in rodent models of muscle wasting and in cachectic patients with cancer or pulmonary disease. Therefore, there is an increasing interest to use serum myostatin as a biomarker. Methods We established an immunoradiometric sandwich assay (IRMA), which uses a commercially available chicken polyclonal, affinity purified antibody directed against human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals as well as 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic pulmonary disease. Results The IRMA had a detection limit of 0.7ng/ml, an intraassay imprecision of ≤14.1% and an interassay imprecision of ≤ 18.9%. The specificity of our assay was demonstrated by size exclusion chromatography, detection of myostatin by Western-blotting and a SMAD-dependent transcriptional-reporter assay in the signal-rich serum fractions, as well as lack of interference by unspecific substances like albumin, hemoglobin or lipids. Myostatin prodomain was stable at room temperature and resistant to freeze-thaw cycles. Apparently healthy individuals over the age of 55 had a median myostatin prodomain serum concentration of 3.9ng/ml (25th-75th percentiles, 2-7ng/ml) and we could not detect increased levels in patients with stable chronic heart failure or cancer related weight loss. In contrast, we found strongly elevated concentrations of myostatin prodomain (median 26.9ng/ml, 25th-75th percentiles, 7-100ng/ml) in the serum of underweight patients with chronic pulmonary disease. Conclusions We established a highly specific IRMA for the quantification of myostatin prodomain concentration in human serum. Our assay could be useful to study myostatin as a biomarker for example in patients with chronic pulmonary disease, as we detected highly

  13. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    Science.gov (United States)

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  14. Correlation of MCP-4 and high-sensitivity C-reactive protein as a marker of inflammation in obesity and chronic periodontitis.

    Science.gov (United States)

    Pradeep, A R; Kumari, Minal; Kalra, Nitish; Priyanka, N

    2013-03-01

    Obesity is increasing in prevalence worldwide and has emerged as a strong risk factor for periodontal disease. Conversely, the remote effects of periodontal disease on various systemic diseases have been proposed. The aim of this study is to determine the presence of MCP-4 and high sensitivity C reactive protein (hsCRP) levels in gingival crevicular fluid (GCF) and serum in obese and non-obese subjects with chronic periodontitis and to find a correlation between MCP-4 and hsCRP in GCF and serum. Forty subjects (20 males and 20 females) were selected and divided into four groups (10 subjects in each group), based on clinical parameters: group NOH (non-obese healthy), group OH (obese healthy), Group NOCP (non-obese with chronic periodontitis) and group OCP (obese with chronic periodontitis). The levels of serum and GCF MCP-4 were determined by ELISA and hsCRP levels were determined by immunoturbidimetry method. The mean GCF and serum concentration of MCP-4 was highest for group OCP followed by group NOCP, group OH (in GCF); group OH, group NOCP(in serum) and least in group NOH. The mean hsCRP concentration was highest for group OCP followed by group OH, group NOCP and group NOH. A significant positive correlation was found between serum and GCF MCP-4 and hsCRP levels. GCF MCP-4 concentrations increased in periodontal disease compared to health and correlated positively with the severity of disease indicating it as a novel marker of periodontal disease. The serum concentration of MCP-4 was found to be more in obese group as compared to nonobese group indicating it as a marker of obesity. Furthermore, based on the positive correlation of MCP-4 and hsCRP found in this study, it can be proposed that MCP-4 and hsCRP may be the markers linking chronic inflammation in obesity and periodontal disease. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    International Nuclear Information System (INIS)

    Takeuchi, Koh; Arthanari, Haribabu; Shimada, Ichio; Wagner, Gerhard

    2015-01-01

    Detection of 15 N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached 15 N nuclei (TROSY 15 N H ) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow 15 N transverse relaxation and compensating for the inherently low 15 N sensitivity. The 15 N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY 15 N H component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a 15 N-detected 2D 1 H– 15 N TROSY-HSQC ( 15 N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ c  ∼ 40 ns). Unlike for 1 H detected TROSY, deuteration is not mandatory to benefit 15 N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording 15 N TROSY of proteins expressed in H 2 O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D 2 O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of 15 N H -detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz

  16. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Koh [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Arthanari, Haribabu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States); Shimada, Ichio, E-mail: shimada@iw-nmr.f.u-tokyo.ac.jp [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Wagner, Gerhard, E-mail: gerhard-wagner@hms.harvard.edu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States)

    2015-12-15

    Detection of {sup 15}N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached {sup 15}N nuclei (TROSY {sup 15}N{sub H}) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow {sup 15}N transverse relaxation and compensating for the inherently low {sup 15}N sensitivity. The {sup 15}N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY {sup 15}N{sub H} component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a {sup 15}N-detected 2D {sup 1}H–{sup 15}N TROSY-HSQC ({sup 15}N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ{sub c} ∼ 40 ns). Unlike for {sup 1}H detected TROSY, deuteration is not mandatory to benefit {sup 15}N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording {sup 15}N TROSY of proteins expressed in H{sub 2}O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D{sub 2}O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of {sup 15}N{sub H}-detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz.

  17. Applications of molecules as high-resolution, high-sensitivity threshold electron detectors

    International Nuclear Information System (INIS)

    Chutjian, A.

    1991-01-01

    The goal of the work under the contract entitled ''Applications of Molecules as High-Resolution, High-Sensitivity Threshold Electron Detectors'' (DoE IAA No. DE-AI01-83ER13093 Mod. A006) was to explore the electron attachment properties of a variety of molecules at electron energies not accessible by other experimental techniques. As a result of this work, not only was a large body of basic data measured on attachment cross sections and rate constants; but also extensive theoretical calculations were carried out to verify the underlying phenomenon of s-wave attachment. Important outgrowths of this week were also realized in other areas of research. The basic data have applications in fields such as combustion, soot reduction, rocket-exhaust modification, threshold photoelectron spectroscopy, and trace species detection

  18. An application of impediography to the high sensitivity and high resolution identification of structural damage

    International Nuclear Information System (INIS)

    Zhao, L; Yang, J; Semperlotti, F; Wang, K W

    2015-01-01

    In this study we explore the use of impediographic techniques to perform damage detection in plate-like metal structures. Impediography relies on the piezo-resistive coupling of the host structure to reconstruct high sensitivity and high resolution maps of the internal electrical conductivity. By exploiting localized strain perturbations generated via focused acoustic waves, the piezo-resistive coupling allows extracting a set of linearly independent boundary voltage data that drastically reduces the ill-conditioning of the inverse problem, therefore increasing the performance. The localized perturbation is achieved by leveraging the concept of frequency selective structure (FSS), that is a dynamically tailored structural element enabling the required acoustic focusing via vibration localization. Based on the FSS approach, the impediographic technique is numerically tested to investigate the performance of the combined approach for structural damage detection. The effects of practical implementation issues, such as limited perturbations and limited boundary data, are also explored. (paper)

  19. Storing quantum information in spins and high-sensitivity ESR.

    Science.gov (United States)

    Morton, John J L; Bertet, Patrice

    2018-02-01

    Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per Hz, with prospects to scale down to even fewer spins. Copyright © 2017. Published by Elsevier Inc.

  20. Storing quantum information in spins and high-sensitivity ESR

    Science.gov (United States)

    Morton, John J. L.; Bertet, Patrice

    2018-02-01

    Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per √{ Hz } , with prospects to scale down to even fewer spins.

  1. Highly sensitive DNA sensors based on cerium oxide nanorods

    Science.gov (United States)

    Nguyet, Nguyen Thi; Hai Yen, Le Thi; Van Thu, Vu; lan, Hoang; Trung, Tran; Vuong, Pham Hung; Tam, Phuong Dinh

    2018-04-01

    In this work, a CeO2 nanorod (NR)-based electrochemical DNA sensor was developed to identify Salmonella that causes food-borne infections. CeO2 NRs were synthesized without templates via a simple and unexpensive hydrothermal approach at 170 °C for 12 h by using CeO(NO3)3·6H2O as a Ce source. The DNA probe was immobilized onto the CeO2 NR-modified electrode through covalent attachment. The characteristics of the hybridized DNA were analyzed through electrochemical impedance spectroscopy (EIS) with [Fe(CN)6]3-/4- as a redox probe. Experimental results showed that electron transfer resistance (Ret) increased after the DNA probe was attached to the electrode surface and increased further after the DNA probe hybridized with its complementary sequence. A linear response of Ret to the target DNA concentration was found from 0.01 μM to 2 μM. The detection limit and sensitivity of the DNA sensor were 0.01 μM and 3362.1 Ω μM-1 cm-2, respectively. Various parameters, such as pH value, ionic strength, DNA probe concentration, and hybridization time, influencing DNA sensor responses were also investigated.

  2. Sensitivity, specificity and predictive probability values of serum agglutination test titres for the diagnosis of Salmonella Dublin culture-positive bovine abortion and stillbirth.

    Science.gov (United States)

    Sánchez-Miguel, C; Crilly, J; Grant, J; Mee, J F

    2018-06-01

    The objective of this study was to determine the diagnostic value of maternal serology for the diagnosis of Salmonella Dublin bovine abortion and stillbirth. A retrospective, unmatched, case-control study was carried out using twenty year's data (1989-2009) from bovine foetal submissions to an Irish government veterinary laboratory. Cases (n = 214) were defined as submissions with a S. Dublin culture-positive foetus from a S. Dublin unvaccinated dam where results of maternal S. Dublin serology were available. Controls (n = 415) were defined as submissions where an alternative diagnosis other than S. Dublin was made in a foetus from an S. Dublin unvaccinated dam where the results of maternal S. Dublin serology were available. A logistic regression model was fitted to the data: the dichotomous dependent variable was the S. Dublin foetal culture result, and the independent variables were the maternal serum agglutination test (SAT) titre results. Salmonella serology correctly classified 87% of S. Dublin culture-positive foetuses at a predicted probability threshold of 0.44 (cut-off at which sensitivity and specificity are at a maximum, J = 0.67). The sensitivity of the SAT at the same threshold was 73.8% (95% CI: 67.4%-79.5%), and the specificity was 93.2% (95% CI: 90.3%-95.4%). The positive and negative predictive values were 84.9% (95% CI: 79.3%-88.6%) and 87.3% (95% CI: 83.5%-91.3%), respectively. This study illustrates that the use of predicted probability values, rather than the traditional arbitrary breakpoints of negative, inconclusive and positive, increases the diagnostic value of the maternal SAT. Veterinary laboratory diagnosticians and veterinary practitioners can recover from the test results, information previously categorized, particularly from those results declared to be inconclusive. © 2017 Blackwell Verlag GmbH.

  3. Clinical significance of high-sensitivity C- reactive protein in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    T. A. Nevskaya

    2007-01-01

    Full Text Available Objective. To determine diagnostic and prognostic significance of high-sensitivity Creactive protein (hsCRP in systemic sclerosis (SS, to define relationship of this factor with activity of the disease and cardiovascular pathology, to assess role of pro-inflammatory cytokines in induction of acute phase proteins synthesis in SS.Material and methods. Serum levels of hsCRP, interleukin (IL 6, IL 1β, IL1ra, IL 10, sIL2r were evaluated by enzyme immunoassay (EIA in 40 pts with SS and 24 subjects of control group. Relationship with clinical features of the disease, endothelial dysfunction, capillaries structure changes, sub-clinical atherosclerosis, total coronary risk and some traditional cardiovascular risk factors was analyzed. Instrumental assessment included nailfold capillaroscopy, sonographic duplex examination of carotids , brachial arte ry sonographic examination. HsCRP prognostic significance was assessed in 51 pts with SS.Results. Elevated levels of hsCRP were found in 32% of SS pts and correlated with activity and severity of the disease, HAQ and SHAQ. Direct correlation of hsCRP with skin fibrosis distribution, interstitial lung disease, arthritis, laboratory indices of SS activity (ESR, sIL2r and Scl-70 was revealed. HsCRP concentration in SS did not depend on character and intensity of cardiovascular pathology, subclinical atherosclerosis, endothelial dysfunction and proinflammatory cytokines production.Conclusion. HsCRP in SS reflects intensity of immuno-inflammatory process, correlates with T-cell activation markers and can be used as index of the disease activity, severity of skin and lung fibrosis.

  4. High serum bicarbonate level within the normal range prevents the progression of chronic kidney disease in elderly chronic kidney disease patients

    Directory of Open Access Journals (Sweden)

    Kanda Eiichiro

    2013-01-01

    Full Text Available Abstract Background Metabolic acidosis leads to chronic kidney disease (CKD progression. The guidelines recommend a lower limit of serum bicarbonate level, but no upper limit. For serum bicarbonate level to be clinically useful as a therapeutic target marker, it is necessary to investigate the target serum bicarbonate level within the normal range to prevent CKD progression. Methods One hundred and thirteen elderly CKD patients, whose serum bicarbonate level was controlled within the normal range, were enrolled in this retrospective cohort study in Ibaraki, Japan. Outcome was defined as a decrease of 25% or more in estimated glomerular filtration rate (eGFR or starting dialysis. We used Cox proportional hazard models adjusted for patients’ characteristics to examine the association between serum bicarbonate level and the outcome. Results Female patients were 36.3%: average age (SD, 70.4 (6.6 years; eGFR, 25.7 (13.6 ml/min/1.73 m2; serum bicarbonate level, 27.4 (3.2 mEq/l. Patients with the lowest quartile of serum bicarbonate levels [23.4 (1.8 mEq/l] showed a high risk of CKD progression compared with patients with high serum bicarbonate levels [28.8 (2.3 mEq/l]: adjusted hazard ratio (HR, 3.511 (95% CI, 1.342-9.186. A 1 mEq/l increase in serum bicarbonate level was associated with a low risk of CKD progression: adjusted HR, 0.791 [95% confidence interval (CI, 0.684-0.914]. Conclusions In elderly CKD patients, our findings suggest that serum bicarbonate level is independently associated with CKD progression, and that a high serum bicarbonate level is associated with a low risk of CKD progression. A high target serum bicarbonate level within the normal range may be effective for preventing CKD progression.

  5. Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Muhammad Nawaz

    2012-01-01

    Full Text Available A rapid and sensitive method using high performance liquid chromatography has been developed and validated for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs in pharmaceutical formulations and human serum. Six NSAIDs including: naproxen sodium, diclofenac sodium, meloxicam, flurbiprofen, tiaprofenic and mefenamic acid were analyzed simultaneously in presence of ibuprofen as internal standard on Mediterranea C18 (5 µm, 250 x 0.46 mm column. Mobile phase comprised of methanol: acetonitrile: H2O (60:20:20, v/v; pH 3.35 and pumped at a flow rate of 1 mL min-1 using 265 nm UV detection. The method was linear over a concentration range of 0.25-50 µg mL-1 (r² = 0.9999.

  6. Highly efficient and stable cyclometalated ruthenium(II) complexes as sensitizers for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Huang, Jian-Feng; Liu, Jun-Min; Su, Pei-Yang; Chen, Yi-Fan; Shen, Yong; Xiao, Li-Min; Kuang, Dai-Bin; Su, Cheng-Yong

    2015-01-01

    Highlights: • Four novel thiocyanate-free cyclometalated ruthenium sensitizer were conveniently synthesized. • The D-CF 3 -sensitized DSSCs show higher efficiency compared to N719 based cells. • The DSSCs based on D-CF 3 and D-bisCF 3 sensitizers exhibit excellent long-term stability. • The diverse cyclometalated Ru complexes can be developed as high-performance sensitizers for use in DSSC. - Abstract: Four novel thiocyanate-free cyclometallted Ru(II) complexes, D-bisCF 3 , D-CF 3 , D-OMe, and D-DPA, with two 4,4′-dicarboxylic acid-2,2′-bipyridine together with a functionalized phenylpyridine ancillary ligand, have been designed and synthesized. The effect of different substituents (R = bisCF 3 , CF 3 , OMe, and DPA) on the ancillary C^N ligand on the photophysical properties and photovoltaic performance is investigated. Under standard global AM 1.5 solar conditions, the device based on D-CF 3 sensitizer gives a higher conversion efficiency of 8.74% than those based on D-bisCF 3 , D-OMe, and D-DPA, which can be ascribed to its broad range of visible light absorption, appropriate localization of the frontier orbitals, weak hydrogen bonds between -CF 3 and -OH groups at the TiO 2 surface, moderate dye loading on TiO 2 , and high charge collection efficiency. Moreover, the D-bisCF 3 and D-CF 3 based DSSCs exhibit good stability under 100 mW cm −2 light soaking at 60 °C for 400 h

  7. Photoelastic colloidal gel for a high-sensitivity strain sensor

    Science.gov (United States)

    Pan, Hui; Chen, Zhixin; Zhu, Shenmin; Jiang, Chun; Zhang, Di

    2018-04-01

    Nanoparticles, having the ability to self-assemble into an ordered structure in their suspensions, analogous to liquid crystals, have attracted extensive attention. Herein, we report a new type of colloidal gel with an ordered crystal structure assembled from 1D and 2D nanoparticles. The material has high elasticity and, more interestingly, it shows significant photoelasticity. Its refractive index can be tuned under external stress and exhibits an ultra-wide dynamic range (Δn) of the order of 10-2. Due to the large Δn, the material shows an extremely high strain sensibility of 720 nm/ɛ, an order of magnitude higher than the reported ones.

  8. High-sensitive CRP as a predictive marker of long-term outcome in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Alberdi-Saugstrup, Mikel; Zak, Marek; Nielsen, Susan

    2017-01-01

    To evaluate whether C-reactive protein (CRP), including variation within the normal range, is predictive of long-term disease outcome in Juvenile Idiopathic Arthritis (JIA). Consecutive patients with newly diagnosed JIA were included prospectively from defined geographic areas of the Nordic...... countries from 1997 to 2000. Inclusion criteria were availability of a baseline serum sample within 12 months after disease onset and 8-year clinical assessment data. Systemic onset JIA was not included. CRP was measured by high-sensitive ELISA (detection limit of 0.2 mg/l). One hundred and thirty...... participants with a median follow-up time of 97 months (range 95–100) were included. At follow-up, 38% of the patients were in remission off medication. Absence of remission was associated with elevated level of CRP at baseline (odds ratio (OR) 1.33, confidence interval (CI) 1.08–1.63, p = 0.007). By applying...

  9. Biological Signatures of Brain Damage Associated with High Serum Ferritin Levels in Patients with Acute Ischemic Stroke and Thrombolytic Treatment

    Directory of Open Access Journals (Sweden)

    Mónica Millán

    2008-01-01

    Full Text Available Background and purpose: Increased body iron stores have been related to greater oxidative stress and brain injury in clinical and experimental cerebral ischemia and reperfusion. We aimed to investigate the biological signatures of excitotoxicity, inflammation and blood brain barrier disruption potentially associated with high serum ferritin levels-related damage in acute stroke patients treated with i.v. t-PA.

  10. High-sensitivity mass spectrometry with a tandem accelerator

    International Nuclear Information System (INIS)

    Henning, W.

    1984-01-01

    The characteristic features of accelerator mass spectrometry are discussed. A short overview is given of the current status of mass spectrometry with high-energy (MeV/nucleon) heavy-ion accelerators. Emphasis is placed on studies with tandem accelerators and on future mass spectrometry of heavier isotopes with the new generation of higher-voltage tandems

  11. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    NARCIS (Netherlands)

    Brantjes, N. P. M.; Dzordzhadze, V.; Gebel, R.; Gonnella, F.; Gray, F. E.; van der Hoek, D. J.; Imig, A.; Kruithof, W. L.; Lazarus, D. M.; Lehrach, A.; Lorentz, B.; Messi, R.; Moricciani, D.; Morse, W. M.; Noid, G. A.; Onderwater, C. J. G.; Ozben, C. S.; Prasuhn, D.; Sandri, P. Levi; Semertzidis, Y. K.; da Silva e Silva, M.; Stephenson, E. J.; Stockhorst, H.; Venanzoni, G.; Versolato, O. O.

    2012-01-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY

  12. Variable high pressure processing sensitivities for GII human noroviruses

    Science.gov (United States)

    Human norovirus (HuNoV) is the leading cause of foodborne diseases worldwide. High pressure processing (HPP) is one of the most promising non-thermal technologies for decontamination of viral pathogens in foods. However, the survival of HuNoVs by HPP is poorly understood because these viruses cann...

  13. High serum folate is associated with reduced biochemical recurrence after radical prostatectomy: Results from the SEARCH Database

    Directory of Open Access Journals (Sweden)

    Daniel M. Moreira

    2013-06-01

    Full Text Available Introduction To analyze the association between serum levels of folate and risk of biochemical recurrence after radical prostatectomy among men from the Shared Equal Access Regional Cancer Hospital (SEARCH database. Materials and Methods Retrospective analysis of 135 subjects from the SEARCH database treated between 1991-2009 with available preoperative serum folate levels. Patients' characteristics at the time of the surgery were analyzed with ranksum and linear regression. Uni- and multivariable analyses of folate levels (log-transformed and time to biochemical recurrence were performed with Cox proportional hazards. Results The median preoperative folate level was 11.6ng/mL (reference = 1.5-20.0ng/mL. Folate levels were significantly lower among African-American men than Caucasians (P = 0.003. In univariable analysis, higher folate levels were associated with more recent year of surgery (P < 0.001 and lower preoperative PSA (P = 0.003. In univariable analysis, there was a trend towards lower risk of biochemical recurrence among men with high folate levels (HR = 0.61, 95%CI = 0.37-1.03, P = 0.064. After adjustments for patients characteristics' and pre- and post-operative clinical and pathological findings, higher serum levels of folate were independently associated with lower risk for biochemical recurrence (HR = 0.42, 95%CI = 0.20-0.89, P = 0.023. Conclusion In a cohort of men undergoing radical prostatectomy at several VAs across the country, higher serum folate levels were associated with lower PSA and lower risk for biochemical failure. While the source of the folate in the serum in this study is unknown (i.e. diet vs. supplement, these findings, if confirmed, suggest a potential role of folic acid supplementation or increased consumption of folate rich foods to reduce the risk of recurrence.

  14. Swimming exercise increases serum irisin level and reduces body fat mass in high-fat-diet fed Wistar rats.

    Science.gov (United States)

    Lu, Yun; Li, Hongwei; Shen, Shi-Wei; Shen, Zhen-Hai; Xu, Ming; Yang, Cheng-Jian; Li, Feng; Feng, Yin-Bo; Yun, Jing-Ting; Wang, Ling; Qi, Hua-Jin

    2016-05-13

    It has been shown that irisin levels are reduced in skeletal muscle and plasma of obese rats; however, the effect of exercise training on irisin level remains controversial. We aim to evaluate the association of swimming exercise with serum irisin level and other obesity-associated parameters. Forty healthy male Wistar rats were randomly assigned to 4 groups: a normal diet and sedentary group (ND group), normal diet and exercise group (NDE group), high-fat diet and sedentary group (HFD group), and high-fat diet and exercise group (HFDE group. After 8 consecutive weeks of swimming exercise, fat mass and serum irisin level was determined. Higher serum irisin levels were detected in the HFDE group (1.15 ± 0.28 μg/L) and NDE group (1.76 ± 0.17 μg/L) than in the HFD group (0.84 ± 0.23 μg/L) or the ND group (1.24 ± 0.29 μg/L), respectively (HFDE group vs. HFD group, P mass (r = -0.68, P mass (r = -0.576, P mass (r = -0.439, P mass, visceral fat mass and percentage fat mass were lower in the HFDE group than the HFD group (all P values mass in high-fat-fed Wistar rats, which may be attributable to elevated irisin levels induced by swimming exercise.

  15. High Sensitivity Indium Phosphide Based Avalanche Photodiode Focal Plane Arrays, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — nLight has demonstrated highly-uniform APD arrays based on the highly sensitive InGaAs/InP material system. These results provide great promise for achieving the...

  16. Highly Sensitive and Reproducible SERS Sensor for Biological pH Detection Based on a Uniform Gold Nanorod Array Platform.

    Science.gov (United States)

    Bi, Liyan; Wang, Yunqing; Yang, Ying; Li, Yuling; Mo, Shanshan; Zheng, Qingyin; Chen, Lingxin

    2018-05-09

    Conventional research on surface-enhanced Raman scattering (SERS)-based pH sensors often depends on nanoparticle aggregation, whereas the variability in nanoparticle aggregation gives rise to poor repeatability in the SERS signal. Herein, we fabricated a gold nanorod array platform via an efficient evaporative self-assembly method. The platform exhibits great SERS sensitivity with an enhancement factor of 5.6 × 10 7 and maintains excellent recyclability and reproducibility with relative standard deviation (RSD) values of less than 8%. On the basis of the platform, we developed a highly sensitive bovine serum albumin (BSA)-coated 4-mercaptopyridine (4-MPy)-linked (BMP) SERS-based pH sensor to report pH ranging from pH 3.0 to pH 8.0. The intensity ratio variation of 1004 and 1096 cm -1 in 4-MPy showed excellent pH sensitivity, which decreased as the surrounding pH increased. Furthermore, this BMP SERS-based pH sensor was employed to measure the pH value in C57BL/6 mouse blood. We have demonstrated that the pH sensor has great advantages such as good stability, reliability, and accuracy, which could be extended for the design of point-of-care devices.

  17. High-sensitivity chemiluminescence immunoassays for detection of growth hormone doping in sports.

    Science.gov (United States)

    Bidlingmaier, Martin; Suhr, Jennifer; Ernst, Andrea; Wu, Zida; Keller, Alexandra; Strasburger, Christian J; Bergmann, Andreas

    2009-03-01

    Recombinant human growth hormone (rhGH) is abused in sports, but adequate routine doping tests are lacking. Analysis of serum hGH isoform composition has been shown to be effective in detecting rhGH doping. We developed and validated selective immunoassays for isoform analysis with potential utility for screening and confirmation in doping tests. Monoclonal antibodies with preference for pituitary hGH (phGH) or rhGH were used to establish 2 pairs of sandwich-type chemiluminescence assays with differential recognition of rhGH (recA and recB) and phGH (pitA and pitB). We analyzed specimens from volunteers before and after administration of rhGH and calculated ratios between the respective rec- and pit-assay results. Functional sensitivities were <0.05 microg/L, with intra- and interassay imprecision < or =8.4% and < or =13.7%, respectively. In 2 independent cohorts of healthy subjects, rec/pit ratios (median range) were 0.84 (0.09-1.32)/0.81 (0.27-1.21) (recA/pitA) and 0.68 (0.08-1.20)/0.80 (0.25-1.36) (recB/pitB), with no sex difference. In 20 recreational athletes, ratios (median SD) increased after a single injection of rhGH, reaching 350% (73%) (recA/pitA) and 400% (93%) (recB/pitB) of baseline ratios. At a moderate dose (0.033 mg/kg), mean recA/pitA and recB/pitB ratios remained significantly increased for 18 h (men) and 26 h (women). After high-dose rhGH (0.083 mg/kg), mean rec/pit ratios remained increased for 32 h (recA/pitA) and 34 h (recB/pitB) in men and were still increased after 36 h in women. Using sensitive chemiluminescence assays with preferential recognition of phGH or rhGH, detection of a single injection of rhGH was possible for up to 36 h.

  18. Quantification of Photocyanine in Human Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in a Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Bing-Tian Bi

    2014-01-01

    Full Text Available Photocyanine is a novel anticancer drug. Its pharmacokinetic study in cancer patients is therefore very important for choosing doses, and dosing intervals in clinical application. A rapid, selective and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS method was developed and validated for the determination of photocyanine in patient serum. Sample preparation involved one-step protein precipitation by adding methanol and N,N-dimethyl formamide to 0.1 mL serum. The detection was performed on a triple quadrupole tandem mass spectrometer operating in multiple reaction-monitoring (MRM mode. Each sample was chromatographed within 7 min. Linear calibration curves were obtained for photocyanine at a concentration range of 20–2000 ng/mL (r>0.995, with the lower limit of quantification (LLOQ being 20 ng/mL. The intrabatch accuracy ranged from 101.98% to 107.54%, and the interbatch accuracy varied from 100.52% to 105.62%. Stability tests showed that photocyanine was stable throughout the analytical procedure. This study is the first to utilize the HPLC-MS/MS method for the pharmacokinetic study of photocyanine in six cancer patients who had received a single dose of photocyanine (0.1 mg/kg administered intravenously.

  19. Serum vitamin E concentrations among highly functioning hip fracture patients are higher than in nonfracture controls

    OpenAIRE

    D’Adamo, Christopher R.; Shardell, Michelle D.; Hicks, Gregory E.; Orwig, Denise L.; Hochberg, Marc C.; Semba, Richard D.; Yu-Yahiro, Janet A.; Ferrucci, Luigi; Magaziner, Jay S.; Miller, Ram R.

    2011-01-01

    Malnutrition after hip fracture is common and associated with poor outcomes and protracted recovery. Low concentrations of vitamin E have been associated with incident decline in physical function among older adults and may, therefore, be particularly important to functionally compromised patients hip fracture patients. Serum concentrations of α-tocopherol and γ-tocopherol, the 2 major forms of vitamin E, were assessed in 148 female hip fracture patients 65 years or older from the Baltimore H...

  20. Highly efficient human serum filtration with water-soluble nanoporous nanoparticles

    Directory of Open Access Journals (Sweden)

    Antonella Pujia

    2010-11-01

    Full Text Available Antonella Pujia1, Francesco De Angelis1,2, Domenica Scumaci3, Marco Gaspari3, Carlo Liberale1,2, Patrizio Candeloro1, Giovanni Cuda3, Enzo Di Fabrizio1,21BIONEM Laboratory, Department of Experimental and Clinical Medicine, University of Catanzaro “Magna Graecia”, Germaneto (CZ, Italy; 2IIT, Italian Institute of Technology, Genova, Italy; 3Proteomics and Mass Spectrometry Laboratory, Department of Experimental and Clinical Medicine, University of Catanzaro “Magna Graecia”, Germaneto (CZ, ItalyBackground: Human serum has the potential to become the most informative source of novel biomarkers, but its study is very difficult due to the incredible complexity of its molecular composition. We describe a novel tool based on biodegradable nanoporous nanoparticles (NPNPs that allows the harvesting of low-molecular-weight fractions of crude human serum or other biofluids. NPNPs with a diameter of 200 nm and pore size of a few nm were obtained by ultrasonication of nanoporous silicon. When incubated with a solution, the NPNPs harvest only the molecules small enough to be absorbed into the nanopores. Then they can be recovered by centrifugation and dissolved in water, making the harvested molecules available for further analyses.Results: Fluorescence microscopy, gel electrophoresis, and mass spectrometry were used to show the enrichment of low-molecular-weight fraction of serum under physiological conditions, with a cut-off of 13 kDa and an enrichment factor >50.Conclusion: From these findings, we conclude that ability to tune pore size, combined with the availability of hundreds of biomolecule cross-linkers, opens up new perspectives on complex biofluid analysis, discovery of biomarkers, and in situ drug delivery.Keywords: nanoporous silicon, nanoparticle, biomarker discovery, human serum proteomics, harvesting

  1. The Role of Serum High Mobility Group Box 1 and Interleukin-6 Levels in Acute Pancreatitis: A Meta-Analysis.

    Science.gov (United States)

    Li, Nuo; Wang, Bao-Ming; Cai, Shuang; Liu, Peng-Liang

    2018-01-01

    The purpose of this meta-analysis was to comprehensively investigate the correlation between high mobility group box 1 (HMGB1) and interleukin-6 (IL-6) in relation to acute pancreatitis. A highly regulated exploration of various electronic databases, supplemented by manual searching methods, was performed in an attempt to identify pertinent articles of a useful nature. Subsequently, high-quality cohort studies that were deemed to comply with the arduous inclusion and exclusion criteria were selected for our meta-analysis. The extensive data analyses reported in our meta-analysis were conducted in connection with the Comprehensive Meta-analysis 2.0 (CMA 2.0). A total of 395 studies (135 Chinese studies and 260 English studies) were initially retrieved. 27 of those studies were selected for our meta-analysis, comprising of 896 cases of mild acute pancreatitis (MAP), 700 cases of severe acute pancreatitis (SAP) as well as 312 healthy controls. Pooled data suggested that serum HMGB1 and IL-6 levels of SAP and MAP patients were higher than in healthy controls. Moreover, serum HMGB1 and IL-6 levels of SAP patients exhibited significantly higher levels than in that of MAP patients. Based on the rigorous investigation of our meta-analysis, it was concluded that serum HMGB1 and IL-6 levels might be used as effective indicators for pancreatic lesions as well as the degree of inflammatory response, owing ultimately to the observations and data analyses, suggesting that serum HMGB1 and IL-6 levels share a close correlation with the severity of pancreatitis. J. Cell. Biochem. 119: 616-624, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Serum progranulin irrelated with Breg cell levels, but elevated in RA patients, reflecting high disease activity.

    Science.gov (United States)

    Chen, Jiaxi; Li, Shuang; Shi, Jianfeng; Zhang, Lili; Li, Jun; Chen, Shiyong; Wu, Chunlong; Shen, Bo

    2016-03-01

    Soluble progranulin (PGRN) is known to directly regulate regulatory T cells; however, whether PGRN levels are elevated in patients with rheumatoid arthritis and affect the regulatory subsets of B cells remain unknown. In this study, a total of 80 RA patients and 60 healthy controls were studied. Serum progranulin levels were determined using enzyme-linked immune-sorbent assay. A receiver operating characteristic (ROC) curve was used to evaluate the feasibility of serum PGRN as a biomarker for distinguishing patients with RA. CD19(+)CD5(+)GrB(+) B cells were analyzed by flow cytometry in peripheral blood mononuclear cells (PBMCs). Serum progranulin levels in RA patients (median, 59.4 ng/mL) and in RA patients DAS28 > 5.1 (median, 71.98 ng/mL) were much higher than those in normal controls (median, 46.3 ng/mL; P progranulin levels was 0.705 for RA versus normal controls and the area under the ROC curve for progranulin levels in RA patients DAS28 > 5.1 was 0.977 versus normal controls (P progranulin and DAS28, CRP, ESR were all positively correlated in RA patients (P 0.05). Our findings indicated that induction of PGRN expression may play a role in RA immune reaction and PGRN levels could be a useful biomarker in RA inflammatory response, but irrelated with Breg cell levels.

  3. The association between etanercept serum concentration and psoriasis severity is highly age-dependent.

    Science.gov (United States)

    Detrez, Iris; Van Steen, Kristel; Segaert, Siegfried; Gils, Ann

    2017-06-01

    The association between etanercept serum concentration and psoriasis disease severity is poorly investigated, and currently etanercept serum concentration monitoring that is aiming to optimize the psoriasis treatment lacks evidence. In this prospective study, we investigated the relation between etanercept exposure and disease severity via measuring etanercept concentrations at five consecutive time points in 56 psoriasis patients. Disease severity assessments included the Psoriasis Area and Severity Index (PASI), body surface area (BSA) and Physician Global Assessment (PGA), and etanercept and anti-etanercept antibody concentrations were determined every 3 months for a period of 1 year. The present study demonstrated that the association between etanercept concentration and psoriasis severity is age-dependent: when patients were stratified into three groups, patients in the youngest age group (-50 years) showed a lower PASI at a higher etanercept concentration (β = -0.26), whereas patients in the oldest age group (+59 years) showed the opposite trend (β =0.22). Similar age effects were observed in the relation of etanercept concentration with BSA ( P =0.02) and PGA ( P =0.02). The influence of age and length of time in therapy on the etanercept concentration-disease severity relation was unaffected by body mass index (BMI) or any other possible confounder. Incidence of anti-etanercept antibodies was low (2%). The age-dependent relation between etanercept serum concentrations is both unexpected and intriguing and needs further investigation. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  4. Proteomic analysis of swine serum following highly virulent classical swine fever virus infection

    Directory of Open Access Journals (Sweden)

    Guo Huan-cheng

    2011-03-01

    Full Text Available Abstract Background Classical swine fever virus (CSFV belongs to the genus Pestivirus within the family Flaviviridae. Virulent strains of classical swine fever virus (CSFV cause severe disease in pigs characterized by immunosuppression, thrombocytopenia and disseminated intravascular coagulation, which causes significant economic losses to the pig industry worldwide. Methods To reveal proteomic changes in swine serum during the acute stage of lethal CSFV infection, 5 of 10 pigs were inoculated with the virulent CSFV Shimen strain, the remainder serving as uninfected controls. A serum sample was taken at 3 days post-infection from each swine, at a stage when there were no clinical symptoms other than increased rectal temperatures (≥40°C. The samples were treated to remove serum albumin and immunoglobulin (IgG, and then subjected to two-dimension differential gel electrophoresis. Results Quantitative intensity analysis revealed 17 protein spots showing at least 1.5-fold quantitative alteration in expression. Ten spots were successfully identified by MALDI-TOF MS or LTQ MS. Expression of 4 proteins was increased and 6 decreased in CSFV-infected pigs. Functions of these proteins included blood coagulation, anti-inflammatory activity and angiogenesis. Conclusion These proteins with altered expression may have important implications in the pathogenesis of classical swine fever and provide a clue for identification of biomarkers for classical swine fever early diagnosis.

  5. Self-powered neutron detector of high sensitivity

    International Nuclear Information System (INIS)

    Brixy, H.; Spillekothen, H.G.; Benninghofen, G.; Serafin, N.

    1983-01-01

    A self-powered neutron detector is proposed, consisting of three concentrically arranged electrically conducting tubes; where the central one forms the emitter and the inner and outer ones form the collector and where the tubes are electrically insulated from each other by insulating material. The emitter consists of a material with a high absorption cross-section for thermal neutrons, particularly of gadolinium, and is provided with an auxiliary emitter layer on the inside or the outside. With suitable dimensions and material, the auxiliary emitter layer increases the yield of electrons. (orig./HP) [de

  6. High sensitivity C-reactive protein distribution in the elderly: the Bambuí Cohort Study, Brazil

    Directory of Open Access Journals (Sweden)

    L.G.S. Assunção

    2012-12-01

    Full Text Available The measurement of the serum concentration of the acute-phase reactant C-reactive protein (CRP provides a useful marker in clinical practice. However, the distribution of CRP is not available for all age and population groups. This study assessed the distribution of high sensitivity-CRP (hs-CRP by gender and age in 1470 elderly individuals from a Brazilian community that participates in the Bambuí Cohort Study. Blood samples were collected after 12 h of fasting and serum samples were stored at -70°C. Measurements were made with a commercial hs-CRP immunonephelometric instrument. More than 50% of the results were above 3.0 mg/L for both genders. Mean hs-CRP was higher in women (3.62 ± 2.58 mg/L than in men (3.03 ± 2.50 mg/L. This difference was observed for all ages, except for the over-80 age group. This is the first population-based study to describe hs-CRP values in Latin American elderly subjects. Our results indicate that significant gender differences exist in the distribution of hs-CRP, and suggest that gender-specific cut-off points for hs-CRP would be necessary for the prediction of cardiovascular risks.

  7. High sensitivity C-reactive protein distribution in the elderly: the Bambuí Cohort Study, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Assunção, L.G.S. [Programa de Pós-Graduação em Patologia, Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Eloi-Santos, S.M. [Programa de Pós-Graduação em Patologia, Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Departamento de Propedêutica Complementar, Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Peixoto, S.V. [Departamento de Enfermagem Aplicada, Escola de Enfermagem, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Centro de Pesquisas René Rachou, Fundação Oswaldo Cruz, Belo Horizonte, MG (Brazil); Lima-Costa, M.F. [Departamento de Medicina Preventiva e Social, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Centro de Pesquisas René Rachou, Fundação Oswaldo Cruz, Belo Horizonte, MG (Brazil); Vidigal, P.G. [Programa de Pós-Graduação em Patologia, Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Departamento de Propedêutica Complementar, Faculdade de Medicina, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2012-09-28

    The measurement of the serum concentration of the acute-phase reactant C-reactive protein (CRP) provides a useful marker in clinical practice. However, the distribution of CRP is not available for all age and population groups. This study assessed the distribution of high sensitivity CRP (hs-CRP) by gender and age in 1470 elderly individuals from a Brazilian community that participates in the Bambuí Cohort Study. Blood samples were collected after 12 h of fasting and serum samples were stored at -70°C. Measurements were made with a commercial hs-CRP immunonephelometric instrument. More than 50% of the results were above 3.0 mg/L for both genders. Mean hs-CRP was higher in women (3.62 ± 2.58 mg/L) than in men (3.03 ± 2.50 mg/L). This difference was observed for all ages, except for the over-80 age group. This is the first population-based study to describe hs-CRP values in Latin American elderly subjects. Our results indicate that significant gender differences exist in the distribution of hs-CRP, and suggest that gender-specific cut-off points for hs-CRP would be necessary for the prediction of cardiovascular risks.

  8. High sensitivity C-reactive protein distribution in the elderly: the Bambuí Cohort Study, Brazil

    International Nuclear Information System (INIS)

    Assunção, L.G.S.; Eloi-Santos, S.M.; Peixoto, S.V.; Lima-Costa, M.F.; Vidigal, P.G.

    2012-01-01

    The measurement of the serum concentration of the acute-phase reactant C-reactive protein (CRP) provides a useful marker in clinical practice. However, the distribution of CRP is not available for all age and population groups. This study assessed the distribution of high sensitivity CRP (hs-CRP) by gender and age in 1470 elderly individuals from a Brazilian community that participates in the Bambuí Cohort Study. Blood samples were collected after 12 h of fasting and serum samples were stored at -70°C. Measurements were made with a commercial hs-CRP immunonephelometric instrument. More than 50% of the results were above 3.0 mg/L for both genders. Mean hs-CRP was higher in women (3.62 ± 2.58 mg/L) than in men (3.03 ± 2.50 mg/L). This difference was observed for all ages, except for the over-80 age group. This is the first population-based study to describe hs-CRP values in Latin American elderly subjects. Our results indicate that significant gender differences exist in the distribution of hs-CRP, and suggest that gender-specific cut-off points for hs-CRP would be necessary for the prediction of cardiovascular risks

  9. An Underwater Acoustic Vector Sensor with High Sensitivity and Broad Band

    Directory of Open Access Journals (Sweden)

    Hu Zhang

    2014-05-01

    Full Text Available Recently, acoustic vector sensor that use accelerators as sensing elements are widely used in underwater acoustic engineering, but the sensitivity of which at low frequency band is usually lower than -220 dB. In this paper, using a piezoelectric trilaminar optimized low frequency sensing element, we designed a high sensitivity internal placed ICP piezoelectric accelerometer as sensing element. Through structure optimization, we made a high sensitivity, broadband, small scale vector sensor. The working band is 10-2000 Hz, sound pressure sensitivity is -185 dB (at 100 Hz, outer diameter is 42 mm, length is 80 mm.

  10. Serine Protease Zymography: Low-Cost, Rapid, and Highly Sensitive RAMA Casein Zymography.

    Science.gov (United States)

    Yasumitsu, Hidetaro

    2017-01-01

    To detect serine protease activity by zymography, casein and CBB stain have been used as a substrate and a detection procedure, respectively. Casein zymography has been using substrate concentration at 1 mg/mL and employing conventional CBB stain. Although ordinary casein zymography provides reproducible results, it has several disadvantages including time-consuming and relative low sensitivity. Improved casein zymography, RAMA casein zymography, is rapid and highly sensitive. RAMA casein zymography completes the detection process within 1 h after incubation and increases the sensitivity at least by tenfold. In addition to serine protease, the method also detects metalloprotease 7 (MMP7, Matrilysin) with high sensitivity.

  11. Highly sensitive determination of atropine using cobalt oxide nanostructures: Influence of functional groups on the signal sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Soomro, Razium Ali, E-mail: raziumsoomro@gmail.com [Interface Analysis Centre, School of Physics, University of Bristol, Bristol, BS8 1TL (United Kingdom); National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Nafady, Ayman [Department of Chemistry, College of Science, King Saud University, Riyadh (Saudi Arabia); Department of Chemistry, Faculty of Science, Sohag University, Sohag (Egypt); Hallam, Keith Richard [Interface Analysis Centre, School of Physics, University of Bristol, Bristol, BS8 1TL (United Kingdom); Jawaid, Sana [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Al Enizi, Abdullah [Department of Chemistry, College of Science, King Saud University, Riyadh (Saudi Arabia); Sherazi, Syed Tufail Hussain; Sirajuddin [National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Ibupoto, Zafar Hussain [Dr M.A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, 76080 (Pakistan); Willander, Magnus [Department of Science and Technology, Campus Norrkoping, Linkoping University, SE-60174, Norrkoping (Sweden)

    2016-12-15

    This study describes sensitive determination of atropine using glassy carbon electrodes (GCE) modified with Co{sub 3}O{sub 4} nanostructures. The as-synthesised nanostructures were grown using cysteine (CYS), glutathione (GSH) and histidine (HYS) as effective templates under hydrothermal action. The obtained morphologies revealed interesting structural features, including both cavity-based and flower-shaped structures. The as-synthesised morphologies were noted to actively participate in electro-catalysis of atropine (AT) drug where GSH-assisted structures exhibited the best signal response in terms of current density and over-potential value. The study also discusses the influence of functional groups on the signal sensitivity of atropine electro-oxidation. The functionalisation was carried with the amino acids originally used as effective templates for the growth of Co{sub 3}O{sub 4} nanostructures. The highest increment was obtained when GSH was used as the surface functionalising agent. The GSH-functionalised Co{sub 3}O{sub 4}-modified electrode was utilised for the electro-chemical sensing of AT in a concentration range of 0.01–0.46 μM. The developed sensor exhibited excellent working linearity (R{sup 2} = 0.999) and signal sensitivity up to 0.001 μM of AT. The noted high sensitivity of the sensor is associated with the synergy of superb surface architectures and favourable interaction facilitating the electron transfer kinetics for the electro-catalytic oxidation of AT. Significantly, the developed sensor demonstrated excellent working capability when used for AT detection in human urine samples with strong anti-interference potential against common co-existing species, such as glucose, fructose, cysteine, uric acid, dopamine and ascorbic acid. - Highlights: • Template-assisted growth of Co{sub 3}O{sub 4} nanostructures. • Shape-dependent electro-catalysis of atropine. • Effect of functionalisation of signal sensitivity.

  12. Sex Differences in High Sensitivity C-Reactive Protein in Subjects with Risk Factors of Metabolic Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, Vinicius Pacheco; Rocha, Helena Naly Miguens [Laboratório de Ciências do Exercício - Departamento de Fisiologia e Farmacologia - Universidade Federal Fluminense, Niterói, RJ (Brazil); Sales, Allan Robson Kluser [Unidade de Reabilitação Cardiovascular e Fisiologia do Exercício - Instituto do Coração (InCor) - Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP (Brazil); Rocha, Natália Galito; Nóbrega, Antonio Claudio Lucas da, E-mail: anobrega@id.uff.br [Laboratório de Ciências do Exercício - Departamento de Fisiologia e Farmacologia - Universidade Federal Fluminense, Niterói, RJ (Brazil)

    2016-03-15

    Metabolic syndrome (MetS) is associated with a higher risk of all-cause mortality. High-sensitivity C-reactive protein (hsCRP) is a prototypic marker of inflammation usually increased in MetS. Women with MetS-related diseases present higher hsCRP levels than men with MetS-related diseases, suggesting sex differences in inflammatory markers. However, it is unclear whether serum hsCRP levels are already increased in men and/or women with MetS risk factors and without overt diseases or under pharmacological treatment. To determine the impact of the number of MetS risk factors on serum hsCRP levels in women and men. One hundred and eighteen subjects (70 men and 48 women; 36 ± 1 years) were divided into four groups according to the number of MetS risk factors: healthy group (CT; no risk factors), MetS ≤ 2, MetS = 3, and MetS ≥ 4. Blood was drawn after 12 hours of fasting for measurement of biochemical variables and hsCRP levels, which were determined by immunoturbidimetric assay. The groups with MetS risk factors presented higher serum hsCRP levels when compared with the CT group (p < 0.02). There were no differences in hsCRP levels among groups with MetS risk factors (p > 0.05). The best linear regression model to explain the association between MetS risk factors and hsCRP levels included waist circumference and HDL cholesterol (r = 0.40, p < 0.01). Women with MetS risk factors presented higher hsCRP levels when compared with men (p{sub sex} < 0.01). Despite the absence of overt diseases and pharmacological treatment, subjects with MetS risk factors already presented increased hsCRP levels, which were significantly higher in women than men at similar conditions.

  13. Sex Differences in High Sensitivity C-Reactive Protein in Subjects with Risk Factors of Metabolic Syndrome

    International Nuclear Information System (INIS)

    Garcia, Vinicius Pacheco; Rocha, Helena Naly Miguens; Sales, Allan Robson Kluser; Rocha, Natália Galito; Nóbrega, Antonio Claudio Lucas da

    2016-01-01

    Metabolic syndrome (MetS) is associated with a higher risk of all-cause mortality. High-sensitivity C-reactive protein (hsCRP) is a prototypic marker of inflammation usually increased in MetS. Women with MetS-related diseases present higher hsCRP levels than men with MetS-related diseases, suggesting sex differences in inflammatory markers. However, it is unclear whether serum hsCRP levels are already increased in men and/or women with MetS risk factors and without overt diseases or under pharmacological treatment. To determine the impact of the number of MetS risk factors on serum hsCRP levels in women and men. One hundred and eighteen subjects (70 men and 48 women; 36 ± 1 years) were divided into four groups according to the number of MetS risk factors: healthy group (CT; no risk factors), MetS ≤ 2, MetS = 3, and MetS ≥ 4. Blood was drawn after 12 hours of fasting for measurement of biochemical variables and hsCRP levels, which were determined by immunoturbidimetric assay. The groups with MetS risk factors presented higher serum hsCRP levels when compared with the CT group (p < 0.02). There were no differences in hsCRP levels among groups with MetS risk factors (p > 0.05). The best linear regression model to explain the association between MetS risk factors and hsCRP levels included waist circumference and HDL cholesterol (r = 0.40, p < 0.01). Women with MetS risk factors presented higher hsCRP levels when compared with men (p sex < 0.01). Despite the absence of overt diseases and pharmacological treatment, subjects with MetS risk factors already presented increased hsCRP levels, which were significantly higher in women than men at similar conditions

  14. Sex Differences in High Sensitivity C-Reactive Protein in Subjects with Risk Factors of Metabolic Syndrome

    Directory of Open Access Journals (Sweden)

    Vinicius Pacheco Garcia

    2016-03-01

    Full Text Available Abstract Background: Metabolic syndrome (MetS is associated with a higher risk of all-cause mortality. High-sensitivity C-reactive protein (hsCRP is a prototypic marker of inflammation usually increased in MetS. Women with MetS-related diseases present higher hsCRP levels than men with MetS-related diseases, suggesting sex differences in inflammatory markers. However, it is unclear whether serum hsCRP levels are already increased in men and/or women with MetS risk factors and without overt diseases or under pharmacological treatment. Objective: To determine the impact of the number of MetS risk factors on serum hsCRP levels in women and men. Methods One hundred and eighteen subjects (70 men and 48 women; 36 ± 1 years were divided into four groups according to the number of MetS risk factors: healthy group (CT; no risk factors, MetS ≤ 2, MetS = 3, and MetS ≥ 4. Blood was drawn after 12 hours of fasting for measurement of biochemical variables and hsCRP levels, which were determined by immunoturbidimetric assay. Results: The groups with MetS risk factors presented higher serum hsCRP levels when compared with the CT group (p 0.05. The best linear regression model to explain the association between MetS risk factors and hsCRP levels included waist circumference and HDL cholesterol (r = 0.40, p < 0.01. Women with MetS risk factors presented higher hsCRP levels when compared with men (psex < 0.01. Conclusions: Despite the absence of overt diseases and pharmacological treatment, subjects with MetS risk factors already presented increased hsCRP levels, which were significantly higher in women than men at similar conditions.

  15. High-speed asynchronous optical sampling for high-sensitivity detection of coherent phonons

    International Nuclear Information System (INIS)

    Dekorsy, T; Taubert, R; Hudert, F; Schrenk, G; Bartels, A; Cerna, R; Kotaidis, V; Plech, A; Koehler, K; Schmitz, J; Wagner, J

    2007-01-01

    A new optical pump-probe technique is implemented for the investigation of coherent acoustic phonon dynamics in the GHz to THz frequency range which is based on two asynchronously linked femtosecond lasers. Asynchronous optical sampling (ASOPS) provides the performance of on all-optical oscilloscope and allows us to record optically induced lattice dynamics over nanosecond times with femtosecond resolution at scan rates of 10 kHz without any moving part in the set-up. Within 1 minute of data acquisition time signal-to-noise ratios better than 10 7 are achieved. We present examples of the high-sensitivity detection of coherent phonons in superlattices and of the coherent acoustic vibration of metallic nanoparticles

  16. High-precision high-sensitivity clock recovery circuit for a mobile payment application

    International Nuclear Information System (INIS)

    Sun Lichong; Yan Na; Min Hao; Ren Wenliang

    2011-01-01

    This paper presents a fully integrated carrier clock recovery circuit for a mobile payment application. The architecture is based on a sampling-detection module and a charge pump phase locked loop. Compared with clock recovery in conventional 13.56 MHz transponders, this circuit can recover a high-precision consecutive carrier clock from the on/off keying (OOK) signal sent by interrogators. Fabricated by a SMIC 0.18-μm EEPROM CMOS process, this chip works from a single power supply as low as 1.5 V Measurement results show that this circuit provides 0.34% frequency deviation and 8 mV sensitivity. (semiconductor integrated circuits)

  17. A Highly Sensitive Rapid Diagnostic Test for Chagas Disease That Utilizes a Recombinant Trypanosoma cruzi Antigen

    Science.gov (United States)

    Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.

    2011-01-01

    Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808

  18. High serum fasting peptide YY (3-36) is associated with obesity-associated insulin resistance and type 2 diabetes.

    Science.gov (United States)

    Ukkola, Olavi H; Puurunen, Veli-Pekka; Piira, Olli-Pekka; Niva, Jarkko T; Lepojärvi, E Samuli; Tulppo, Mikko P; Huikuri, Heikki V

    2011-10-10

    We studied whether serum fasting levels of active form of peptide YY (PYY), PYY(3-36), are associated with obesity and related phenotypes. The study population consisted of 428 patients with coronary artery disease and diagnosed type 2 diabetes and 440 patients with coronary artery disease but without evidence of diabetes from the ARTEMIS study. The patients were recruited from the consecutive series of patients undergoing coronary angiography in the Oulu University Hospital. The patients without diabetes underwent a 2-hour oral glucose tolerance test. PYY(3-36) levels were analyzed by human PYY(3-36) specific radioimmunoassay. Result suggested that when PYY(3-36) tertiles were considered, high serum fasting PYY(3-36) concentration was associated with high body mass index, waist circumference, hemoglobin A1c, fasting blood glucose, leptin, triglyceride (p for all p ≤ 0.001), serum insulin (p=0.013) and with a low high-density lipoprotein cholesterol (p=0.004) concentrations in the analyses adjusted for age, sex and study group. The link high PYY(3-36)-high insulin level was evident in subjects with normal glucose tolerance (pfasting glucose, impaired glucose tolerance and normal glucose tolerance (pfasting PYY(3-36) concentrations in type 2 diabetic subjects are high. Although high PYY(3-36) is strongly linked to obesity and associated insulin resistance, the relation between PYY(3-36) and type 2 diabetes is independent of body fatness. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. High Quality Rapeseed Products as Feed for Sensitive Monogastrics

    DEFF Research Database (Denmark)

    Frandsen, Heidi Blok

    in plants of the order Brassicales (former known as Capparales), which include rapeseed, rype (Brassica campestris L.) Indian mustard (Brassica juncea L.), broccoli (Brassica oleracea L.var. italica) and many other plants. Glucosinolates have been studied widely for their biologic effects ranging from...... by xenobiotica enzymes in the liver. The last study (manuscript IV) deals with the novel processing techniques, pulsed electric field (PEF) and high pressure treatment (HPT) and the processing effects on glucosinolates in broccoli. The largest effects were observed to be a result of the different handling...... of the plant materials prior to the process treatment. It was thus found that a great amount of the glucosinolate loss has occurred in the broccoli juice and purée prior to PEF processing. Only a minor loss was observed in broccoli flowers prior to processing, and HP treatment at 700 MPa for 10 min. was found...

  20. Inhibition of serum cholesterol oxidation by dietary vitamin C and selenium intake in high fat fed rats.

    Science.gov (United States)

    Menéndez-Carreño, M; Ansorena, D; Milagro, F I; Campión, J; Martínez, J A; Astiasarán, I

    2008-04-01

    Cholesterol oxidation products (COPs) have been considered as specific in vivo markers of oxidative stress. In this study, an increased oxidative status was induced in Wistar rats by feeding them a high-fat diet (cafeteria diet). Another group of animals received the same diet supplemented with a combination of two different antioxidants, ascorbic acid (100 mg/kg rat/day) and sodium selenite (200 microg/kg rat/day) and a third group fed on a control diet. Total and individual COPs analysis of the different diets showed no differences among them. At the end of the experimental trial, rats were sacrificed and serum cholesterol, triglycerides and COPs were measured. None of the diets induced changes in rats body weight, total cholesterol and triglycerides levels. Serum total COPs in rats fed on the high-fat diet were 1.01 microg/ml, two times the amount of the control rats (0.47 microg/ml). When dietary antioxidant supplementation was given, serum total COPs concentration (0.44 microg/ml) showed the same levels than those of the rats on control diet. 7beta-hydroxycholesterol, formed non-enzymatically via cholesterol peroxidation in the presence of reactive oxygen species, showed slightly lower values in the antioxidant-supplemented animals compared to the control ones. This study confirms the importance of dietary antioxidants as protective factors against the formation of oxysterols.

  1. Silicon nanowire structures as high-sensitive pH-sensors

    International Nuclear Information System (INIS)

    Belostotskaya, S O; Chuyko, O V; Kuznetsov, A E; Kuznetsov, E V; Rybachek, E N

    2012-01-01

    Sensitive elements for pH-sensors created on silicon nanostructures were researched. Silicon nanostructures have been used as ion-sensitive field effect transistor (ISFET) for the measurement of solution pH. Silicon nanostructures have been fabricated by 'top-down' approach and have been studied as pH sensitive elements. Nanowires have the higher sensitivity. It was shown, that sensitive element, which is made of 'one-dimensional' silicon nanostructure have bigger pH-sensitivity as compared with 'two-dimensional' structure. Integrated element formed from two p- and n-type nanowire ISFET ('inverter') can be used as high sensitivity sensor for local relative change [H+] concentration in very small volume.

  2. Classifying low-grade and high-grade bladder cancer using label-free serum surface-enhanced Raman spectroscopy and support vector machine

    Science.gov (United States)

    Zhang, Yanjiao; Lai, Xiaoping; Zeng, Qiuyao; Li, Linfang; Lin, Lin; Li, Shaoxin; Liu, Zhiming; Su, Chengkang; Qi, Minni; Guo, Zhouyi

    2018-03-01

    This study aims to classify low-grade and high-grade bladder cancer (BC) patients using serum surface-enhanced Raman scattering (SERS) spectra and support vector machine (SVM) algorithms. Serum SERS spectra are acquired from 88 serum samples with silver nanoparticles as the SERS-active substrate. Diagnostic accuracies of 96.4% and 95.4% are obtained when differentiating the serum SERS spectra of all BC patients versus normal subjects and low-grade versus high-grade BC patients, respectively, with optimal SVM classifier models. This study demonstrates that the serum SERS technique combined with SVM has great potential to noninvasively detect and classify high-grade and low-grade BC patients.

  3. A novel high resolution, high sensitivity SPECT detector for molecular imaging of cardiovascular diseases

    Science.gov (United States)

    Cusanno, F.; Argentieri, A.; Baiocchi, M.; Colilli, S.; Cisbani, E.; De Vincentis, G.; Fratoni, R.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Lucentini, M.; Magliozzi, M. L.; Majewski, S.; Marano, G.; Musico, P.; Musumeci, M.; Santavenere, F.; Torrioli, S.; Tsui, B. M. W.; Vitelli, L.; Wang, Y.

    2010-05-01

    Cardiovascular diseases are the most common cause of death in western countries. Understanding the rupture of vulnerable atherosclerotic plaques and monitoring the effect of innovative therapies of heart failure is of fundamental importance. A flexible, high resolution, high sensitivity detector system for molecular imaging with radionuclides on small animal models has been designed for this aim. A prototype has been built using tungsten pinhole and LaBr3(Ce) scintillator coupled to Hamamatsu Flat Panel PMTs. Compact individual-channel readout has been designed, built and tested. Measurements with phantoms as well as pilot studies on mice have been performed, the results show that the myocardial perfusion in mice can be determined with sufficient precision. The detector will be improved replacing the Hamamatsu Flat Panel with Silicon Photomultipliers (SiPMs) to allow integration of the system with MRI scanners. Application of LaBr3(Ce) scintillator coupled to photosensor with high photon detection efficiency and excellent energy resolution will allow dual-label imaging to monitor simultaneously the cardiac perfusion and the molecular targets under investigation during the heart therapy.

  4. Clinical value of serum bilirubin subfractionation by high-performance liquid chromatography and conventional methods in patients with primary biliary cirrhosis

    NARCIS (Netherlands)

    Jansen, P. L.; Peters, W. H.; Janssens, A. R.

    1986-01-01

    The clinical value of serum bilirubin subfractionation, using high-performance liquid chromatography (HPLC), was studied in 26 patients with primary biliary cirrhosis (PBC) from whom 59 serum samples were obtained. Total bilirubin (TB) levels were determined by alkaline methanolysis and HPLC

  5. beta-Glucuronidase-resistant bilirubin glucuronide isomers in cholestatic liver disease--determination of bilirubin metabolites in serum by means of high-pressure liquid chromatography

    NARCIS (Netherlands)

    Jansen, P. L.

    1981-01-01

    "Direct reacting bilirubin" in serum of patients with cholestatic liver disease and in serum of bile duct-ligated rats consists of a complex mixture of bilirubin metabolites. These metabolites were studied by means of high-pressure liquid chromatography. Bilirubin glucuronides in normal bile are

  6. A one-step separation of human serum high density lipoproteins 2 and 3 by rate-zonal density gradient ultracentrifugation in a swinging bucket rotor

    NARCIS (Netherlands)

    Groot, P.H.E.; Scheek, L.M.; Havekes, L.; Noort, W.L. van; Hooft, F.M. van 't

    1982-01-01

    A method was developed for the separation of the high density lipoprotein subclasses HDL2 and HDL3 from human serum. Six serum samples are fractionated in a single-step ultracentrifugal procedure using the Beckman (SW-40) swinging bucket rotor. The method is based on a difference in flotation rate

  7. Nanowire-templated microelectrodes for high-sensitivity pH detection

    DEFF Research Database (Denmark)

    Antohe, V.A.; Radu, Adrian; Mátéfi-Tempfli, Mária

    2009-01-01

    A highly sensitive pH capacitive sensor has been designed by confined growth of vertically aligned nanowire arrays on interdigited microelectrodes. The active surface of the device has been functionalized with an electrochemical pH transducer (polyaniline). We easily tune the device features...... by combining lithographic techniques with electrochemical synthesis. The reported electrical LC resonance measurements show considerable sensitivity enhancement compared to conventional capacitive pH sensors realized with microfabricated interdigited electrodes. The sensitivity can be easily improved...

  8. Eating high-fat chow enhances sensitization to the effects of methamphetamine on locomotion in rats.

    Science.gov (United States)

    McGuire, Blaine A; Baladi, Michelle G; France, Charles P

    2011-05-11

    Eating high-fat chow can modify the effects of drugs acting directly or indirectly on dopamine systems and repeated intermittent drug administration can markedly increase sensitivity (i.e., sensitization) to the behavioral effects of indirect-acting dopamine receptor agonists (e.g., methamphetamine). This study examined whether eating high-fat chow alters the sensitivity of male Sprague Dawley rats to the locomotor stimulating effects of acute or repeated administration of methamphetamine. The acute effects of methamphetamine on locomotion were not different between rats (n=6/group) eating high-fat or standard chow for 1 or 4 weeks. Sensitivity to the effects of methamphetamine (0.1-10mg/kg, i.p.) increased progressively across 4 once per week tests; this sensitization developed more rapidly and to a greater extent in rats eating high-fat chow as compared with rats eating standard chow. Thus, while eating high-fat chow does not appear to alter sensitivity of rats to acutely-administered methamphetamine, it significantly increases the sensitization that develops to repeated intermittent administration of methamphetamine. These data suggest that eating certain foods influences the development of sensitization to drugs acting on dopamine systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. CONSTRUCTION OF A DIFFERENTIAL ISOTHERMAL CALORIMETER OF HIGH SENSITIVITY AND LOW COST.

    OpenAIRE

    Trinca, RB; Perles, CE; Volpe, PLO

    2009-01-01

    CONSTRUCTION OF A DIFFERENTIAL ISOTHERMAL CALORIMETER OF HIGH SENSITIVITY AND LOW COST The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes (fie construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 mu L. The calorimeter was built using two small high sensibility square Peltier thermoelectric sensors and the total cost was estimated to be about...

  10. Interaction of dietary sucrose and fiber on serum lipids in healthy young men fed high carbohydrate diets.

    Science.gov (United States)

    Albrink, M J; Ullrich, I H

    1986-03-01

    High sucrose diets may cause increased serum triglycerides and decreased high density lipoprotein concentration. To determine whether dietary fiber protects against these effects, four groups of six healthy young men were assigned to one of four very high carbohydrate diets providing 0, 18, 36, or 52% of calories as sucrose. Each diet was fed in both low (less than 14 g) and high (greater than 34 g) levels of dietary fiber for 10 days each. Triglycerides increased during the 36 and 52% sucrose diets compared to 0 and 18% sucrose diets, and fiber protected partially against this rise. Serum cholesterol and LDL cholesterol were lower during the 0 and 18% sucrose diets than the 36 or 52% sucrose diets but fiber had no effect. HDL cholesterol decreased during all low fat diets, with a trend toward a greater decrease during the high sucrose diets. The results suggest that fiber protects against carbohydrate-induced lipemia but has no effect on cholesterol during very high carbohydrate diets.

  11. High serum resistin is associated with an increase in adiposity but not a worsening of insulin resistance in Pima Indians

    DEFF Research Database (Denmark)

    de Courten, Barbora; Degawa-Yamauchi, Mikako; Considine, Robert V

    2004-01-01

    Resistin is an adipokine with putative prodiabetogenic properties. Like other hormones secreted by adipose tissue, resistin is being investigated as a possible etiologic link between excessive adiposity and insulin resistance. Although there is growing evidence that circulating levels...... of this adipokine are proportional to the degree of adiposity, an effect on insulin resistance in humans remains unproven. To evaluate the relations among resistin, obesity, and insulin resistance, we measured fasting serum resistin levels in 113 nondiabetic (75-g oral glucose tolerance test) Pima Indians (ages 29...... +/- 7 years, body fat 31 +/- 8%, resistin 3.7 +/- 1.1 ng/ml [means +/- SD]), who were characterized for body composition (assessed by hydrodensitometry or dual-energy X-ray absorptiometry), whole-body insulin sensitivity (M; assessed by hyperinsulinemic clamp), basal hepatic glucose output (BHGO...

  12. Possible factors influencing high serum Prostate-specific Antigen (PSA in Indonesian patients with Benign Prostatic Hyperplasia (BPH

    Directory of Open Access Journals (Sweden)

    Djoko Rahardjo

    2001-03-01

    Full Text Available Benign prostatic hyperplasia (BPH cases in Indonesia frequently associated with high serum prostate specific antigen (PSA. To explore possible factors that could increase serum PSA level, we performed a retrospective, cross-sectional study on 805 consecutive patients in Sumber Waras and Dr. Cipto Mangunkusumo Hospitals from 1994 to 1997. Clinical manifestations were evaluated and prostate biopsies were performed if indicated. Complete histopathological data were only available in 82 BPH patients with no urinary retention from 1998-1999 and a thin section of paraffin blocks of BPH patients which still could be found from 1994-1999 was analyzed using flow cytometer to obtain the S-phase fraction as a parameter of proliferative activity, From 805 patients, 461 (57% presented with urinary retention and need to be catheteized. Catheteization significantly increased PSA level if compared to noncatheterized patients (16.3 vs. 6,8 ng/mL, p= 0,000. Another data of 82 uncatheteized patients from 1998-1999 has revealed that 79 patients (96.3% had chronic prostatitis and 19 (23.2% showed the presence of prostatic-intraepithelial neoplasia (PIN with an increase of PSA level (5.4 ng/mL. The S-phase fraction of BPH without PIN cases was significantly higher in cases with PSA > 4 ng/ml than patients with PSA ≤ 4 ng/ml (I3.1% vs. 8.9%, p=0,008. As conclusion, the high serum PSA level was mostly due to urethral catheteization and increased prostate volume. There was a tendency of increasing PSA in subclinical inflammation and PIN. Cases with high PSA also showed high proliferative activities which is suggestive of mitogenic activity. (Med J Indones 2001; 10:22-8Keywords: BPH, high PSA, PIN, proliferative activity, s-phase fraction

  13. Correlates of High Serum C-Reactive Protein Levels in a Socioeconomically Disadvantaged Population

    Directory of Open Access Journals (Sweden)

    Xianglan Zhang

    2008-01-01

    Full Text Available Individuals from low socioeconomic backgrounds are disproportionately affected by the burden of cardiovascular disease (CVD, yet data regarding risk factors in this population are lacking, particularly regarding emerging biomarkers of CVD such as C-reactive protein (CRP. We measured high-sensitivity CRP and examined its association with demographic and lifestyle factors in a sample of 792 participants aged 40–79 years from the Southern Community Cohort Study, which has an over-representation of socioeconomically disadvantaged individuals (over 60% with a total annual household income 3 mg/L varied significantly by sex, race, smoking status, and body mass index (BMI. The multivariable-adjusted prevalence odds ratios (ORs (95% CIs for having elevated CRP were 1.6 (1.1–2.3 for women vs. men, 1.4 (0.9–2.0 for African Americans vs. whites, 2.3 (1.4–3.8 for African American women vs. white men, 1.8 (1.2–2.7 for current smokers vs. non-smokers, and 4.2 (2.7–6.6 for obese (BMI 30.0–44.9 kg/m2 vs. healthy-weight (BMI 18.3–24.9 kg/m2 participants. Further stratified analyses revealed that the association between BMI and elevated CRP was stronger among African Americans than whites and women than men, with prevalence ORs (95% CI comparing obese vs. healthy-weight categories reaching 22.8 (7.1–73.8 for African American women. In conclusion, in this socioeconomically disadvantaged population, sex, race, smoking, and BMI were associated with elevated CRP. Moreover, inflammatory response to obesity differed by race and sex, which may contribute to CVD disparities.

  14. Development of the "Highly Sensitive Dog" questionnaire to evaluate the personality dimension "Sensory Processing Sensitivity" in dogs.

    Directory of Open Access Journals (Sweden)

    Maya Braem

    Full Text Available In humans, the personality dimension 'sensory processing sensitivity (SPS', also referred to as "high sensitivity", involves deeper processing of sensory information, which can be associated with physiological and behavioral overarousal. However, it has not been studied up to now whether this dimension also exists in other species. SPS can influence how people perceive the environment and how this affects them, thus a similar dimension in animals would be highly relevant with respect to animal welfare. We therefore explored whether SPS translates to dogs, one of the primary model species in personality research. A 32-item questionnaire to assess the "highly sensitive dog score" (HSD-s was developed based on the "highly sensitive person" (HSP questionnaire. A large-scale, international online survey was conducted, including the HSD questionnaire, as well as questions on fearfulness, neuroticism, "demographic" (e.g. dog sex, age, weight; age at adoption, etc. and "human" factors (e.g. owner age, sex, profession, communication style, etc., and the HSP questionnaire. Data were analyzed using linear mixed effect models with forward stepwise selection to test prediction of HSD-s by the above-mentioned factors, with country of residence and dog breed treated as random effects. A total of 3647 questionnaires were fully completed. HSD-, fearfulness, neuroticism and HSP-scores showed good internal consistencies, and HSD-s only moderately correlated with fearfulness and neuroticism scores, paralleling previous findings in humans. Intra- (N = 447 and inter-rater (N = 120 reliabilities were good. Demographic and human factors, including HSP score, explained only a small amount of the variance of HSD-s. A PCA analysis identified three subtraits of SPS, comparable to human findings. Overall, the measured personality dimension in dogs showed good internal consistency, partial independence from fearfulness and neuroticism, and good intra- and inter

  15. High serum carotenoids are associated with lower risk for developing elevated serum alanine aminotransferase among Japanese subjects: the Mikkabi cohort study.

    Science.gov (United States)

    Sugiura, Minoru; Nakamura, Mieko; Ogawa, Kazunori; Ikoma, Yoshinori; Yano, Masamichi

    2016-04-01

    Many recent studies have shown that antioxidant vitamins and/or carotenoids may reduce liver disease, but this association has not been well established with thorough longitudinal cohort studies. The objective of this study was to longitudinally investigate whether serum carotenoids at baseline are associated with the risk of developing elevated serum alanine aminotransferase (ALT) among Japanese subjects. We conducted a follow-up study of 1073 males and females aged between 30 and 79 years at baseline from the Mikkabi prospective cohort study. Those who participated in the baseline study and completed follow-up surveys were examined longitudinally. Exclusions included excessive alcohol consumption (≥60 g alcohol/d), hepatitis B and C and having a history of medication use for liver disease. A cohort of 213 males and 574 females free of elevated serum ALT (>30 IU/ml) at baseline was studied. Over a mean follow-up period of 7·4 (sd 3·1) years, thirty-one males and forty-nine females developed new elevated serum ALT. After adjustments for confounders, the hazard ratios for elevated serum ALT in the highest tertiles of basal serum β-carotene, β-cryptoxanthin and total provitamin A carotenoids against the lowest tertiles were 0·43 (95 % CI 0·22, 0·81), 0·51 (CI 0·27, 0·94) and 0·52 (CI 0·28, 0·97), respectively. For α-carotene and lycopene, borderline reduced risks were also observed; however, these were not significant. Our results further support the hypothesis that antioxidant carotenoids, especially provitamin A carotenoids, might help prevent earlier pathogenesis of non-alcoholic liver disease in Japanese subjects.

  16. Differential sensitivity of long-sleep and short-sleep mice to high doses of cocaine.

    Science.gov (United States)

    de Fiebre, C M; Ruth, J A; Collins, A C

    1989-12-01

    The cocaine sensitivity of male and female long-sleep (LS) and short-sleep (SS) mice, which have been selectively bred for differential ethanol-induced "sleep-time," was examined in a battery of behavioral and physiological tests. Differences between these two mouse lines were subtle and were seen primarily at high doses. At high doses, SS mice were more sensitive than LS mice, particularly to cocaine-induced hypothermia; however, significant hypothermia was not seen except at doses which were very near to the seizure threshold. During a 60-min test of locomotor activity, LS mice showed greater stimulation of Y-maze activity by 20 mg/kg cocaine than SS mice. Consistent with the finding of subtle differences in sensitivity to low doses of cocaine. LS and SS mice did not differ in sensitivity to cocaine inhibition of synaptosomal uptake of [3H]-dopamine, [3H]-norepinephrine or [3H]-5-hydroxytryptamine. However, consistent with the finding of differential sensitivity to high doses of cocaine, SS mice were more sensitive to the seizure-producing effects of the cocaine and lidocaine, a local anesthetic. It is hypothesized that the differential sensitivity of these mouse lines to high doses of cocaine is due to differential sensitivity to cocaine's actions on systems that regulate local anesthetic effects. Selective breeding for differential duration of alcohol-induced "sleep-time" may have resulted in differential ion channel structure or function in these mice.

  17. Organic dye for highly efficient solid-state dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt-Mende, L.; Bach, U.; Humphry-Baker, R.; Ito, S.; Graetzel, M. [Institut des Sciences et Ingenierie Chimiques (ISIC), Laboratoire de Photonique et Interfaces (LPI), Ecole Polytechnique Federale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Horiuchi, T.; Miura, H. [Technology Research Laboratory, Corporate Research Center, Mitsubishi Paper Mills Limited, 46, Wadai, Tsukuba City, Ibaraki 300-4247 (Japan); Uchida, S. [Institute of Multidisciplinary Research for Advanced Materials (IMRAM), Tohoku University, 1-1 Katahira 2-chome, Aoba-ku, Sendai 980-8577 (Japan)

    2005-04-04

    The feasibility of solid-state dye-sensitized solar cells as a low-cost alternative to amorphous silicon cells is demonstrated. Such a cell with a record efficiency of over 4 % under simulated sunlight is reported, made possible by using a new organic metal-free indoline dye as the sensitizer with high absorption coefficient. (Abstract Copyright [2005], Wiley Periodicals, Inc.)

  18. High serum soluble tumor necrosis factor receptor 1 predicts poor treatment response in acute-stage schizophrenia.

    Science.gov (United States)

    Nishimon, Shohei; Ohnuma, Tohru; Takebayashi, Yuto; Katsuta, Narimasa; Takeda, Mayu; Nakamura, Toru; Sannohe, Takahiro; Higashiyama, Ryoko; Kimoto, Ayako; Shibata, Nobuto; Gohda, Tomohito; Suzuki, Yusuke; Yamagishi, Sho-Ichi; Tomino, Yasuhiko; Arai, Heii

    2017-06-02

    Inflammation may be involved in the pathophysiology of schizophrenia. However, few cross-sectional or longitudinal studies have examined changes in biomarker expression to evaluate diagnostic and prognostic efficacy in acute-stage schizophrenia. We compared serum inflammatory biomarker concentrations in 87 patients with acute-stage schizophrenia on admission to 105 age-, sex-, and body mass index (BMI)-matched healthy controls. The measured biomarkers were soluble tumor necrosis factor receptor 1 (sTNFR1) and adiponectin, which are associated with inflammatory responses, and pigment epithelium-derived factor (PEDF), which has anti-inflammatory properties. We then investigated biomarker concentrations and associations with clinical factors in 213 patients (including 42 medication-free patients) and 110 unmatched healthy controls to model conditions typical of clinical practice. Clinical symptoms were assessed using the Brief Psychiatric Rating Scale and Global Assessment of Function. In 121 patients, biomarker levels and clinical status were evaluated at both admission and discharge. Serum sTNFR1 was significantly higher in patients with acute-stage schizophrenia compared to matched controls while no significant group differences were observed for the other markers. Serum sTNFR1 was also significantly higher in the 213 patients compared to unmatched controls. The 42 unmedicated patients had significantly lower PEDF levels compared to controls. Between admission and discharge, sTNFR1 levels decreased significantly; however, biomarker changes did not correlate with clinical symptoms. The discriminant accuracy of sTNFR1 was 93.2% between controls and patients, showing no symptom improvement during care. Inflammation and a low-level anti-inflammatory state may be involved in both schizophrenia pathogenesis and acute-stage onset. High serum sTNFR1 in the acute stage could be a useful prognostic biomarker for treatment response in clinical practice. Copyright © 2017

  19. [Changing laws of serum high mobility group box 1 protein in septic rats and the intervention effect of xuebijing].

    Science.gov (United States)

    Zhao, Shi-bing; He, Xian-di; Wang, Hua-xue; Zheng, Sheng-yong; Deng, Xi-ming; Duan, Li-bin

    2014-06-01

    To investigate the changing laws of serum high mobility group box 1 protein (HMGB1) in septic rats and intervention effect of Xuebijing on it. Lipopolysaccharide (LPS) (5 mg/kg BW) was intravenously injected into the tail vein of healthy male Wistar rats to prepare the sepsis rat model. In Experiment 1: 50 Wistar rats were randomly divided into three groups, i.e., the normal group (A, n=10); the LPS model group (B, n=10), the LPS +Xuebijing treatment group (C, n=30). Rats in the C group were further divided into three subgroups, i.e., 2 h before LPS injection (group C1), 2 h after LPS injection (group C2), and 8 h after LPS injection (group C3), 10 in each group. Blood samples were collected from the caudal vein to detect serum HMGB1 levels by Western blot at 4, 12, 24, 48, and 72 h after LPS injection. Experiment 2: 30 Wistar rats were equally divided into the LPS model group (D) and the LPS + Xuebijing treatment group (E), 15 in each group. They were treated as rats in the B group and the C1 group respectively. Five rats were sacrificed at 12, 24, and 48 h after LPS injection in the two groups. Blood as well as the tissue samples were harvested to measure such indices as ALT, AST, Cr, and BUN, as well as pathological changes of liver, lung, and kidney. (1) Compared with the A group, serum HMGB1 levels were higher at various time points in the B group (P decrement in the C3 group was less than that in the C1 and C2 groups (P multiple organ dysfunction. Xuebijing could reduce the serum levels of HMGB1, improve biochemical parameters, and attenuate severe inflammatory response of liver, lung, and kidney tissues in septic rats. Besides, the earlier use, the better effect obtained.

  20. High serum carotenoids associated with lower risk for the metabolic syndrome and its components among Japanese subjects: Mikkabi cohort study.

    Science.gov (United States)

    Sugiura, Minoru; Nakamura, Mieko; Ogawa, Kazunori; Ikoma, Yoshinori; Yano, Masamichi

    2015-11-28

    Recent epidemiological studies show the association of carotenoids with the metabolic syndrome (MetS), but thorough longitudinal cohort studies regarding this association have not been well conducted. The objective of this study was to investigate longitudinally whether serum carotenoids are associated with the risk of developing the MetS and its components in Japanese subjects. We conducted a follow-up study on 1073 men and women aged 30-79 years at the baseline from the Mikkabi prospective cohort study. Those who participated in the baseline and completed follow-up surveys were examined longitudinally. Over the 10-year period, 910 subjects (295 men and 615 women) took part in the follow-up survey at least once. Over a mean follow-up period of 7·8 (sd 2·9) years, thirty-six men and thirty-one women developed new MetS. After adjustments for confounders, the hazard ratio (HR) for the MetS in the highest tertile of serum β-carotene against the lowest tertile was 0·47 (95 % CI 0·23, 0·95). On the other hand, significantly lower risks for dyslipidaemia were observed in the highest tertiles of serum α- and β-carotene and β-cryptoxanthin (HR 0·66; 95 % CI 0·46, 0·96; HR, 0·54; 95 % CI 0·37, 0·79; and HR 0·66; 95 % CI 0·44, 0·99, respectively). Other significant associations between the risks for obesity, high blood pressure and hyperglycaemia with serum carotenoids were not observed. Our results further support the hypothesis that eating a diet rich in carotenoids might help prevent the development of the MetS and its complications in Japanese subjects.

  1. Benefit of adjuvant interferon alfa-2b (IFN-α) therapy in melanoma patients with high serum MMP-8 levels

    DEFF Research Database (Denmark)

    Vihinen, Pia; Tervahartiala, Taina; Sorsa, Timo

    2015-01-01

    Matrix metalloproteinases (MMPs) are important enzymes in tissue turnover and various inflammatory processes. In this study, it was evaluated whether serum MMP-8 can predict the response to adjuvant interferon alfa-2b (IFN-α) therapy in patients with operated high-risk cutaneous melanoma. Pre......-treatment sera from 460 patients with stage IIB-IIIC melanoma were analyzed for MMP-8. The patients were randomized after surgery to adjuvant IFN-α for 12 or 24 months (n = 313) or observation only (n = 147). The median serum MMP-8 level was used to classify the patients into a low MMP-8 (n = 232) and a high MMP......-8 (n = 228) group. In the high MMP-8 subgroup, IFN-α therapy significantly improved relapse-free survival (RFS). RFS was 36.8 months in patients with high MMP-8 levels receiving IFN-α therapy, whereas RFS for those with high MMP-8 levels with observation only was 10.6 months (P = 0.027). Median...

  2. A novel photoelectrochemical immunosensor by integration of nanobody and TiO2 nanotubes for sensitive detection of serum cystatin C

    International Nuclear Information System (INIS)

    Mi, Li; Wang, Pingyan; Yan, Junrong; Qian, Jing; Lu, Jusheng; Yu, Jiachao; Wang, Yuzhen; Liu, Hong; Zhu, Min; Wan, Yakun; Liu, Songqin

    2016-01-01

    Cystatin C (CysC) is a sensitive marker for the estimation of the glomerular filtration rate and the clinical diagnosis of different diseases. In this paper, CysC-specific nanobodies (Nbs) were isolated from a phage display nanobody library. A simple and sensitive photoelectrochemical immunosensor based on TiO 2 nanotube arrays (TNAs) was proposed for the sensitive detection of CysC. The TiO 2 nanotube arrays deposited by electrochemical anodization displayed a high and stable photocurrent response under irradiation. After coupling CysC-specific nanobody to TNA (Nb/TNA), the proposed immunosensor for CysC can be utilized for tracking the photocurrent change of Nb/TNA caused by immunoreactions between CysC and the immobilized CysC-specific Nb. This allowed for the determination of CysC with a calibration range from 0.72 pM to 7.19 nM. The variation of the photocurrent was in a linear relationship with the logarithm of the CysC concentration in the range of 0.72 pM–3.6 nM. The immunosensor had a correlation coefficient of 0.97 and a detection limit of 0.14 pM at a signal-to-noise ratio of 3. The proposed immunosensor showed satisfactory intra- and inter-assay accuracy, high selectivity and good stability. As a result, this proposed strategy would offer a novel and simple approach for the detection of immunoreactions, provide new insights in popularizing the diagnosis of CysC, and extend the application of TiO 2 nanotubes. - Highlights: • CysC-specific nanobody to CysC is isolated from phage display nanobody library. • A photoelectrochemical immunosensor for CysC develops by Nb modified TNA. • An excellent sensitivity and good selectivity of CysC sensing was obtained.

  3. A novel photoelectrochemical immunosensor by integration of nanobody and TiO{sub 2} nanotubes for sensitive detection of serum cystatin C

    Energy Technology Data Exchange (ETDEWEB)

    Mi, Li [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Wang, Pingyan; Yan, Junrong [Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203 (China); Qian, Jing; Lu, Jusheng; Yu, Jiachao [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China); Wang, Yuzhen; Liu, Hong [Plexera LLC, WA 98072 (United States); Zhu, Min [Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203 (China); Wan, Yakun, E-mail: ywansystemsbiology@gmail.com [Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203 (China); Jiangsu Nanobody Engineering and Research Center, Nantong 226010 (China); Liu, Songqin, E-mail: liusq@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189 (China)

    2016-01-01

    Cystatin C (CysC) is a sensitive marker for the estimation of the glomerular filtration rate and the clinical diagnosis of different diseases. In this paper, CysC-specific nanobodies (Nbs) were isolated from a phage display nanobody library. A simple and sensitive photoelectrochemical immunosensor based on TiO{sub 2} nanotube arrays (TNAs) was proposed for the sensitive detection of CysC. The TiO{sub 2} nanotube arrays deposited by electrochemical anodization displayed a high and stable photocurrent response under irradiation. After coupling CysC-specific nanobody to TNA (Nb/TNA), the proposed immunosensor for CysC can be utilized for tracking the photocurrent change of Nb/TNA caused by immunoreactions between CysC and the immobilized CysC-specific Nb. This allowed for the determination of CysC with a calibration range from 0.72 pM to 7.19 nM. The variation of the photocurrent was in a linear relationship with the logarithm of the CysC concentration in the range of 0.72 pM–3.6 nM. The immunosensor had a correlation coefficient of 0.97 and a detection limit of 0.14 pM at a signal-to-noise ratio of 3. The proposed immunosensor showed satisfactory intra- and inter-assay accuracy, high selectivity and good stability. As a result, this proposed strategy would offer a novel and simple approach for the detection of immunoreactions, provide new insights in popularizing the diagnosis of CysC, and extend the application of TiO{sub 2} nanotubes. - Highlights: • CysC-specific nanobody to CysC is isolated from phage display nanobody library. • A photoelectrochemical immunosensor for CysC develops by Nb modified TNA. • An excellent sensitivity and good selectivity of CysC sensing was obtained.

  4. RAMA casein zymography: Time-saving and highly sensitive casein zymography for MMP7 and trypsin.

    Science.gov (United States)

    Yasumitsu, Hidetaro; Ozeki, Yasuhiro; Kanaly, Robert A

    2016-11-01

    To detect metalloproteinase-7 (MMP7), zymography is conducted using a casein substrate and conventional CBB stain. It has disadvantages because it is time consuming and has low sensitivity. Previously, a sensitive method to detect MMP7 up to 30 pg was reported, however it required special substrates and complicated handlings. RAMA casein zymography described herein is rapid, sensitive, and reproducible. By applying high-sensitivity staining with low substrate conditions, the staining process is completed within 1 h and sensitivity was increased 100-fold. The method can detect 10 pg MMP7 by using commercially available casein without complicated handlings. Moreover, it increases detection sensitivity for trypsin. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Prototype of high resolution PET using resistive electrode position sensitive CdTe detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Matsuyama, Shigeo; Yamazaki, Hiromichi

    2008-01-01

    Downsizing detector elements makes it possible that spatial resolutions of positron emission tomography (PET) cameras are improved very much. From this point of view, semiconductor detectors are preferable. To obtain high resolution, the pixel type or the multi strip type of semiconductor detectors can be used. However, in this case, there is a low packing ratio problem, because a dead area between detector arrays cannot be neglected. Here, we propose the use of position sensitive semiconductor detectors with resistive electrode. The CdTe detector is promising as a detector for PET camera because of its high sensitivity. In this paper, we report development of prototype of high resolution PET using resistive electrode position sensitive CdTe detectors. We made 1-dimensional position sensitive CdTe detectors experimentally by changing the electrode thickness. We obtained 750 A as an appropriate thickness of position sensitive detectors, and evaluated the performance of the detector using a collimated 241 Am source. A good position resolution of 1.2 mm full width half maximum (FWHM) was obtained. On the basis of the fundamental development of resistive electrode position sensitive detectors, we constructed a prototype of high resolution PET which was a dual head type and was consisted of thirty-two 1-dimensional position sensitive detectors. In conclusion, we obtained high resolutions which are 0.75 mm (FWHM) in transaxial, and 1.5 mm (FWHM) in axial. (author)

  6. Determination of acrolein in serum by high-performance liquid chromatography with fluorescence detection after pre-column fluorogenic derivatization using 1,2-diamino-4,5-dimethoxybenzene.

    Science.gov (United States)

    Imazato, Takahiro; Kanematsu, Mariko; Kishikawa, Naoya; Ohyama, Kaname; Hino, Takako; Ueki, Yukitaka; Maehata, Eisuke; Kuroda, Naotaka

    2015-09-01

    Acrolein is a major unsaturated aldehyde that is generated during the lipid peroxidation process. The measurement of acrolein in biological samples should be useful to estimate the degree of lipid peroxidation and to evaluate the effect of hazardous properties of acrolein on human health. In this study, a highly sensitive and selective high-performance liquid chromatography with fluorescence detection method was developed for the determination of acrolein in human serum. The proposed method involves the pre-column fluorogenic derivatization of acrolein with 1,2-diamino-4,5-dimethoxybenzene (DDB) as a reagent. The fluorescent derivative of acrolein could be detected clearly without any interfering reagent blank peaks because DDB does not have intrinsic fluorescence itself, and the detection limit was 10 nM (signal-to-noise ratio = 3). The proposed method could selectively detect acrolein in human serum with a simple protein precipitation treatment. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Highly sensitive optical chemosensor for the detection of Cu using a ...

    Indian Academy of Sciences (India)

    Administrator

    Highly sensitive colorimetric chemosensor molecule RHN for selective detection of Cu. 2+ in ... colour development against the colourless blank during the sensing event, a feature that would facilitate ... ever reported, much attention has been.

  8. A highly sensitive, low-cost, wearable pressure sensor based on conductive hydrogel spheres

    KAUST Repository

    Tai, Yanlong; Mulle, Matthieu; Ventura, Isaac Aguilar; Lubineau, Gilles

    2015-01-01

    Wearable pressure sensing solutions have promising future for practical applications in health monitoring and human/machine interfaces. Here, a highly sensitive, low-cost, wearable pressure sensor based on conductive single-walled carbon nanotube

  9. A new method of removing the high value feedback resistor in the charge sensitive preamplifier

    International Nuclear Information System (INIS)

    Xi Deming

    1993-01-01

    A new method of removing the high value feedback resistor in the charge sensitive preamplifier is introduced. The circuit analysis of this novel design is described and the measured performances of a practical circuit are provided

  10. High-Q Fabry–Pérot Micro-Cavities for High-Sensitivity Volume Refractometry

    Directory of Open Access Journals (Sweden)

    Noha Gaber

    2018-01-01

    Full Text Available This work reports a novel structure for a Fabry–Pérot micro cavity that combines the highest reported quality factor for an on-chip Fabry–Pérot resonator that exceeds 9800, and a very high sensitivity for an on-chip volume refractometer based on a Fabry–Pérot cavity that is about 1000 nm/refractive index unit (RIU. The structure consists of two cylindrical Bragg micromirrors that achieve confinement of the Gaussian beam in the plan parallel to the chip substrate, while for the perpendicular plan, external fiber rod lenses (FRLs are placed in the optical path of the input and the output of the cavity. This novel structure overcomes number of the drawbacks presented in previous designs. The analyte is passed between the mirrors, enabling its detection from the resonance peak wavelengths of the transmission spectra. Mixtures of ethanol and deionized (DI-water with different ratios are used as analytes with different refractive indices to exploit the device as a micro-opto-fluidic refractometer. The design criteria are detailed and the modeling is based on Gaussian-optics equations, which depicts a scenario closer to reality than the usually used ray-optics modeling.

  11. High-throughput, Highly Sensitive Analyses of Bacterial Morphogenesis Using Ultra Performance Liquid Chromatography*

    Science.gov (United States)

    Desmarais, Samantha M.; Tropini, Carolina; Miguel, Amanda; Cava, Felipe; Monds, Russell D.; de Pedro, Miguel A.; Huang, Kerwyn Casey

    2015-01-01

    The bacterial cell wall is a network of glycan strands cross-linked by short peptides (peptidoglycan); it is responsible for the mechanical integrity of the cell and shape determination. Liquid chromatography can be used to measure the abundance of the muropeptide subunits composing the cell wall. Characteristics such as the degree of cross-linking and average glycan strand length are known to vary across species. However, a systematic comparison among strains of a given species has yet to be undertaken, making it difficult to assess the origins of variability in peptidoglycan composition. We present a protocol for muropeptide analysis using ultra performance liquid chromatography (UPLC) and demonstrate that UPLC achieves resolution comparable with that of HPLC while requiring orders of magnitude less injection volume and a fraction of the elution time. We also developed a software platform to automate the identification and quantification of chromatographic peaks, which we demonstrate has improved accuracy relative to other software. This combined experimental and computational methodology revealed that peptidoglycan composition was approximately maintained across strains from three Gram-negative species despite taxonomical and morphological differences. Peptidoglycan composition and density were maintained after we systematically altered cell size in Escherichia coli using the antibiotic A22, indicating that cell shape is largely decoupled from the biochemistry of peptidoglycan synthesis. High-throughput, sensitive UPLC combined with our automated software for chromatographic analysis will accelerate the discovery of peptidoglycan composition and the molecular mechanisms of cell wall structure determination. PMID:26468288

  12. Identification and mapping of linear antibody epitopes in human serum albumin using high-density Peptide arrays.

    Directory of Open Access Journals (Sweden)

    Lajla Bruntse Hansen

    Full Text Available We have recently developed a high-density photolithographic, peptide array technology with a theoretical upper limit of 2 million different peptides per array of 2 cm(2. Here, we have used this to perform complete and exhaustive analyses of linear B cell epitopes of a medium sized protein target using human serum albumin (HSA as an example. All possible overlapping 15-mers from HSA were synthesized and probed with a commercially available polyclonal rabbit anti-HSA antibody preparation. To allow for identification of even the weakest epitopes and at the same time perform a detailed characterization of key residues involved in antibody binding, the array also included complete single substitution scans (i.e. including each of the 20 common amino acids at each position of each 15-mer peptide. As specificity controls, all possible 15-mer peptides from bovine serum albumin (BSA and from rabbit serum albumin (RSA were included as well. The resulting layout contained more than 200.000 peptide fields and could be synthesized in a single array on a microscope slide. More than 20 linear epitope candidates were identified and characterized at high resolution i.e. identifying which amino acids in which positions were needed, or not needed, for antibody interaction. As expected, moderate cross-reaction with some peptides in BSA was identified whereas no cross-reaction was observed with peptides from RSA. We conclude that high-density peptide microarrays are a very powerful methodology to identify and characterize linear antibody epitopes, and should advance detailed description of individual specificities at the single antibody level as well as serologic analysis at the proteome-wide level.

  13. Identification and mapping of linear antibody epitopes in human serum albumin using high-density Peptide arrays.

    Science.gov (United States)

    Hansen, Lajla Bruntse; Buus, Soren; Schafer-Nielsen, Claus

    2013-01-01

    We have recently developed a high-density photolithographic, peptide array technology with a theoretical upper limit of 2 million different peptides per array of 2 cm(2). Here, we have used this to perform complete and exhaustive analyses of linear B cell epitopes of a medium sized protein target using human serum albumin (HSA) as an example. All possible overlapping 15-mers from HSA were synthesized and probed with a commercially available polyclonal rabbit anti-HSA antibody preparation. To allow for identification of even the weakest epitopes and at the same time perform a detailed characterization of key residues involved in antibody binding, the array also included complete single substitution scans (i.e. including each of the 20 common amino acids) at each position of each 15-mer peptide. As specificity controls, all possible 15-mer peptides from bovine serum albumin (BSA) and from rabbit serum albumin (RSA) were included as well. The resulting layout contained more than 200.000 peptide fields and could be synthesized in a single array on a microscope slide. More than 20 linear epitope candidates were identified and characterized at high resolution i.e. identifying which amino acids in which positions were needed, or not needed, for antibody interaction. As expected, moderate cross-reaction with some peptides in BSA was identified whereas no cross-reaction was observed with peptides from RSA. We conclude that high-density peptide microarrays are a very powerful methodology to identify and characterize linear antibody epitopes, and should advance detailed description of individual specificities at the single antibody level as well as serologic analysis at the proteome-wide level.

  14. High Serum Advanced Glycation End Products Are Associated with Decreased Insulin Secretion in Patients with Type 2 Diabetes: A Brief Report

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Okura

    2017-01-01

    Full Text Available Objective. Advanced glycation end products (AGEs are important in the pathophysiology of type 2 diabetes mellitus (T2DM. They directly cause insulin secretory defects in animal and cell culture models and may promote insulin resistance in nondiabetic subjects. We have developed a highly sensitive liquid chromatography-tandem mass spectrometry method for measuring AGEs in human serum. Here, we use this method to investigate the relationship between AGEs and insulin secretion and resistance in patients with T2DM. Methods. Our study involved 15 participants with T2DM not on medication and 20 nondiabetic healthy participants. We measured the AGE carboxyethyllysine (CEL, carboxymethyllysine (CML, and methyl-glyoxal-hydro-imidazolone (MG-H1. Plasma glucose and insulin were measured in these participants during a meal tolerance test, and the glucose disposal rate was measured during a euglycemic-hyperinsulinemic clamp. Results. CML and CEL levels were significantly higher in T2DM than non-DM participants. CML showed a significant negative correlation with insulin secretion, HOMA-%B, and a significant positive correlation with the insulin sensitivity index in T2DM participants. There was no correlation between any of the AGEs measured and glucose disposal rate. Conclusions. These results suggest that AGE might play a role in the development or prediction of insulin secretory defects in type 2 diabetes.

  15. Highly sensitive and selective detection of dopamine using one-pot synthesized highly photoluminescent silicon nanoparticles.

    Science.gov (United States)

    Zhang, Xiaodong; Chen, Xiaokai; Kai, Siqi; Wang, Hong-Yin; Yang, Jingjing; Wu, Fu-Gen; Chen, Zhan

    2015-03-17

    A simple and highly efficient method for dopamine (DA) detection using water-soluble silicon nanoparticles (SiNPs) was reported. The SiNPs with a high quantum yield of 23.6% were synthesized by using a one-pot microwave-assisted method. The fluorescence quenching capability of a variety of molecules on the synthesized SiNPs has been tested; only DA molecules were found to be able to quench the fluorescence of these SiNPs effectively. Therefore, such a quenching effect can be used to selectively detect DA. All other molecules tested have little interference with the dopamine detection, including ascorbic acid, which commonly exists in cells and can possibly affect the dopamine detection. The ratio of the fluorescence intensity difference between the quenched and unquenched cases versus the fluorescence intensity without quenching (ΔI/I) was observed to be linearly proportional to the DA analyte concentration in the range from 0.005 to 10.0 μM, with a detection limit of 0.3 nM (S/N = 3). To the best of our knowledge, this is the lowest limit for DA detection reported so far. The mechanism of fluorescence quenching is attributed to the energy transfer from the SiNPs to the oxidized dopamine molecules through Förster resonance energy transfer. The reported method of SiNP synthesis is very simple and cheap, making the above sensitive and selective DA detection approach using SiNPs practical for many applications.

  16. High-level maternal serum Alpha Feto Protein (AFP and ultrasonography findings in second trimester pregnancies

    Directory of Open Access Journals (Sweden)

    Bulent Cakmak

    2015-03-01

    Results: AFP levels were detected over 2.5 MoM in 122 (1.14% of 8552 pregnant women. There were no pathologic findings in 85.2% (104/122 of cases, but 14.8% (18/122 of cases had pathologic results; neural tube defect (NTD 9% (11/122 and anhidroamnios 2.5% (3/122. Omphalocele, polycystic kidney, sacrococcygeal teratoma, placental chorangioma were detected in 0.8% ratio. NTDs were found in 11 (0.12% of 8552 pregnant women who evaluated for maternal serum AFP (MSAFP. Conclusion: The routine use of MSAFP may be queried in NTD screening due to common usage of sufficient fetal anatomic ultrasound scan. [J Contemp Med 2015; 5(1.000: 8-12

  17. The administration of long-term high-fat diet in ovariectomized wistar rat (Study on Daily Food Intake, Lee Index, Abdominal Fat Mass and Leptin Serum Levels

    Directory of Open Access Journals (Sweden)

    Dita Fitriani

    2016-12-01

    Conclusion: Serum leptin levels positively correlated with Lee index and abdominal fat mass, but negatively correlated with daily food intake. Administration of long-term high-fat diet in this study cannot induce leptin resistance.

  18. A novel high sensitivity HPLC assay for topiramate, using 4-chloro-7-nitrobenzofurazan as pre-column fluorescence derivatizing agent.

    Science.gov (United States)

    Bahrami, Gholamreza; Mohammadi, Bahareh

    2007-05-01

    A new, sensitive and simple high-performance liquid chromatographic method for analysis of topiramate, an antiepileptic agent, using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent is described. Following liquid-liquid extraction of topiramate and an internal standard (amlodipine) from human serum, derivatization of the drugs was performed by the labeling agent in the presence of dichloromethane, methanol, acetonitrile and borate buffer (0.05 M; pH 10.6). A mixture of sodium phosphate buffer (0.05 M; pH 2.4): methanol (35:65 v/v) was eluted as mobile phase and chromatographic separation was achieved using a Shimpack CLC-C18 (150 x 4.6 mm) column. In this method the limit of quantification of 0.01 microg/mL was obtained and the procedure was validated over the concentration range of 0.01 to 12.8 microg/mL. No interferences were found from commonly co-administrated antiepileptic drugs including phenytoin, phenobarbital carbamazepine, lamotrigine, zonisamide, primidone, gabapentin, vigabatrin, and ethosuximide. The analysis performance was carried-out in terms of specificity, sensitivity, linearity, precision, accuracy and stability and the method was shown to be accurate, with intra-day and inter-day accuracy from -3.4 to 10% and precise, with intra-day and inter-day precision from 1.1 to 18%.

  19. Changes in Lean Mass and Serum Myostatin with Habitual Protein Intake and High-Velocity Resistance Training.

    Science.gov (United States)

    Binns, A; Gray, M; Henson, A C; Fort, I L

    2017-01-01

    Examine the associations between dietary protein intake, lean mass (LM), and serum myostatin (Mstn) levels among community-dwelling older adults participating in a 20-week high-velocity resistance training (HVRT) program. This longitudinal study consisted of 33 community-dwelling, older adults (mean age 77.0 years, SD = 6.4); all of which obtained physician clearance prior to study participation. Twenty-five females and eight males were randomized to a control (CON) or HVRT group. Anthropometric measures were obtained via dual energy x-ray absorptiometry (DXA) and peripheral venous blood draw used for serum myostatin analysis. Exercise was performed twice per week for 20 consecutive weeks. Food intake estimation with a diet history questionnaire (DHQ) was used for protein intake comparison to the recommended dietary allowance (RDA). All measures were recorded both prior to and following study participation. Altogether, protein was consumed in amounts more generous (1.01 ± 0.47 g·kg-1·d-1) than that of the RDA (0.8 g·kg-1·d-1). As a result of significant LM differences among men and women (p myostatin was greater among females (6681.8 ± 3155.0 pg·mL-1) than males (5560.0 ± 2946.1 pg·mL-1); however, these values were not significantly different (p = 0.39). Combined, protein consumption and serum myostatin did not significantly influence LM among males (p = 0.09) or females (p = 0.71). Irrespective of training group, significant changes were not exhibited in dietary intake patterns, LM, or serum myostatin. Contrary to the proposed hypothesis, results suggest protein consumption and circulating serum myostatin levels did not significantly influence LM among older adults. Although HVRT positively impacts LM, neither exercise group displayed significant changes in LM. Therefore, further research is needed examining dietary intake, exercise modality, and myostatin downregulation as non-pharmacological approaches to combating sarcopenia.

  20. Depleted Nanocrystal-Oxide Heterojunctions for High-Sensitivity Infrared Detection

    Science.gov (United States)

    2015-08-28

    Approved for Public Release; Distribution Unlimited Final Report: 4.3 Electronic Sensing - Depleted Nanocrystal- Oxide Heterojunctions for High...reviewed journals: Final Report: 4.3 Electronic Sensing - Depleted Nanocrystal- Oxide Heterojunctions for High-Sensitivity Infrared Detection Report Title...PERCENT_SUPPORTEDNAME FTE Equivalent: Total Number: 1 1 Final Progress Report Project title: Depleted Nanocrystal- Oxide Heterojunctions for High

  1. Highly sensitive immunoassay based on E. coli with autodisplayed Z-domain

    International Nuclear Information System (INIS)

    Jose, Joachim; Park, Min; Pyun, Jae-Chul

    2010-01-01

    The Z-domain of protein A has been known to bind specifically to the F c region of antibodies (IgGs). In this work, the Z-domain of protein A was expressed on the outer membrane of Escherichia coli by using 'Autodisplay' technology as a fusion protein of autotransport domain. The E. coli with autodisplayed Z-domain was applied to the sandwich-type immunoassay as a solid-support of detection-antibodies against a target analyte. For the feasibility demonstration of the E. coli based immunoassay, C-reactive protein (CRP) assay was carried out by using E. coli with autodisplayed Z-domain. The limit of detection (LOD) and binding capacity of the E. coli based immunoassay were estimated to be far more sensitive than the conventional ELISA. Such a far higher sensitivity of E. coli based immunoassay than conventional ELISA was explained by the orientation control of immobilized antibodies and the mobility of E. coli in assay matrix. From the test results of 45 rheumatoid arthritis (RA) patients' serum and 15 healthy samples, a cut-off value was established to have optimal sensitivity and selectivity values for RA. The CRP test result of each individual sample was compared with ELISA which is the reference method for RA diagnosis. From this work, the E. coli with Z-domain was proved to be feasible for the medical diagnosis based on sandwich-type immunoassay.

  2. Monte carlo calculation of energy-dependent response of high-sensitive neutron monitor, HISENS

    International Nuclear Information System (INIS)

    Imanaka, Tetsuji; Ebisawa, Tohru; Kobayashi, Keiji; Koide, Hiroaki; Seo, Takeshi; Kawano, Shinji

    1988-01-01

    A highly sensitive neutron monitor system, HISENS, has been developed to measure leakage neutrons from nuclear facilities. The counter system of HISENS contains a detector bank which consists of ten cylindrical proportional counters filled with 10 atm 3 He gas and a paraffin moderator mounted in an aluminum case. The size of the detector bank is 56 cm high, 66 cm wide and 10 cm thick. It is revealed by a calibration experiment using an 241 Am-Be neutron source that the sensitivity of HISENS is about 2000 times as large as that of a typical commercial rem-counter. Since HISENS is designed to have a high sensitivity in a wide range of neutron energy, the shape of its energy dependent response curve cannot be matched to that of the dose equivalent conversion factor. To estimate dose equivalent values from neutron counts by HISENS, it is necessary to know the energy and angular characteristics of both HISENS and the neutron field. The area of one side of the detector bank is 3700 cm 2 and the detection efficiency in the constant region of the response curve is about 30 %. Thus, the sensitivity of HISENS for this energy range is 740 cps/(n/cm 2 /sec). This value indicates the extremely high sensitivity of HISENS as compared with exsisting highly sensitive neutron monitors. (Nogami, K.)

  3. A novel detection platform for parallel monitoring of DNA hybridization with high sensitivity and specificity

    DEFF Research Database (Denmark)

    Yi, Sun; Perch-Nielsen, Ivan R.; Wang, Zhenyu

    We developed a high-sensitive platform to monior multiple hybridization events in real time. By creating a microoptical array in a polymeric chip, the system combine the excellent discriminative power of supercritical angle fluorescence (SAF) microscopy with high-throughput capabilities of microa......We developed a high-sensitive platform to monior multiple hybridization events in real time. By creating a microoptical array in a polymeric chip, the system combine the excellent discriminative power of supercritical angle fluorescence (SAF) microscopy with high-throughput capabilities...

  4. A novel stable 3D luminescent uranyl complex for highly efficient and sensitive recognition of Ru3+ and biomolecules

    Science.gov (United States)

    Tian, Hong-Hong; Chen, Liang-Ting; Zhang, Rong-Lan; Zhao, Jian-She; Liu, Chi-Yang; Weng, Ng Seik

    2018-02-01

    A novel highly stable 3D luminescent uranyl coordination polymer, namely {[UO2(L)]·DMA}n (1), was assembled with uranyl salt and a glycine-derivative ligand [6-(carboxymethyl-amino)-4-oxo-4,5-dihydro-[1,3,5]triazin-2-ylamino]-acetic acid (H2L) under solvothermal reaction. Besides, It was found that complex 1 possesses excellent luminescent properties, particularly the efficient selectivity and sensitivity in the recognition of Ru3+, biomacromolecule bovine serum albumin (BSA), biological small molecules dopamine (DA), ascorbic acid (AA) and uric acid (UA) in the water solution based on a "turn-off" mechanism. Accordingly, the luminescent explorations also demonstrated that complex 1 could be acted as an efficient luminescent probe with high quenching efficiency and low detection limit for selectively detecting Ru3+ and biomolecules (DA, AA, UA and BSA). It was noted that the framework structure of complex 1 still remains highly stable after quenching, which was verified by powder X-ray diffraction (PXRD).

  5. Highly Specific Estrone Sulfate Antibody Production Using Hapten-Bovine Serum Albumin Conjugate And Modified Tailoring

    International Nuclear Information System (INIS)

    ELBANNA, I.M.; GAMAL, M.H.; SALEM, A.

    2009-01-01

    Estrone-3-sulfate represents an important estrogenic metabolite indicative to uterine function during early pregnancy and post-partum in animals. Exploiting preparation of less expensive estrone-3-sulfate bovine serum albumin (BSA) conjugate was persuaded for raising antiserum in rabbits. The use of estrone rabbit gamma globulin conjugate as a tollerogenic agent was used to investigate the effect on specificity of the harvested antiserum. Five male New Zealand rabbits were used. After immunization procedure, blood samples were collected and individual bleedings were evaluated for titre and specificity using estrone-3-sulfate- 3 H as a tracer. The tollerogenic pre-immunization procedure gave more specific antiserum than the conventional immunization method. Nevertheless, the titre was lower in tollerogenic than conventional method (1/3500 and 1/4900 as working final dilution, respectively). It is concluded that preparation of E1 -3-sulfate oxime-BSA gave more suitable yield with less expense as compared with previous studies. Pre-immunization injection of tollerogen gave more specific antiserum while the lower titre could be improved after further booster immunization.

  6. Annotation of the human serum metabolome by coupling three liquid chromatography methods to high-resolution mass spectrometry.

    Science.gov (United States)

    Boudah, Samia; Olivier, Marie-Françoise; Aros-Calt, Sandrine; Oliveira, Lydie; Fenaille, François; Tabet, Jean-Claude; Junot, Christophe

    2014-09-01

    This work aims at evaluating the relevance and versatility of liquid chromatography coupled to high resolution mass spectrometry (LC/HRMS) for performing a qualitative and comprehensive study of the human serum metabolome. To this end, three different chromatographic systems based on a reversed phase (RP), hydrophilic interaction chromatography (HILIC) and a pentafluorophenylpropyl (PFPP) stationary phase were used, with detection in both positive and negative electrospray modes. LC/HRMS platforms were first assessed for their ability to detect, retain and separate 657 metabolite standards representative of the chemical families occurring in biological fluids. More than 75% were efficiently retained in either one LC-condition and less than 5% were exclusively retained by the RP column. These three LC/HRMS systems were then evaluated for their coverage of serum metabolome. The combination of RP, HILIC and PFPP based LC/HRMS methods resulted in the annotation of about 1328 features in the negative ionization mode, and 1358 in the positive ionization mode on the basis of their accurate mass and precise retention time in at least one chromatographic condition. Less than 12% of these annotations were shared by the three LC systems, which highlights their complementarity. HILIC column ensured the greatest metabolome coverage in the negative ionization mode, whereas PFPP column was the most effective in the positive ionization mode. Altogether, 192 annotations were confirmed using our spectral database and 74 others by performing MS/MS experiments. This resulted in the formal or putative identification of 266 metabolites, among which 59 are reported for the first time in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Biological Signatures of Brain Damage Associated with High Serum Ferritin Levels in Patients with Acute Ischemic Stroke and Thrombolytic Treatment

    Science.gov (United States)

    Millán, Mónica; Sobrino, Tomás; Arenillas, Juan Francisco; Rodríguez-Yáñez, Manuel; García, María; Nombela, Florentino; Castellanos, Mar; de la Ossa, Natalia Pérez; Cuadras, Patricia; Serena, Joaquín; Castillo, José; Dávalos, Antoni

    2008-01-01

    Background and purpose: Increased body iron stores have been related to greater oxidative stress and brain injury in clinical and experimental cerebral ischemia and reperfusion. We aimed to investigate the biological signatures of excitotoxicity, inflammation and blood brain barrier disruption potentially associated with high serum ferritin levels-related damage in acute stroke patients treated with i.v. t-PA. Methods: Serum levels of ferritin (as index of increased cellular iron stores), glutamate, interleukin-6, matrix metalloproteinase-9 and cellular fibronectin were determined in 134 patients treated with i.v. t-PA within 3 hours from stroke onset in blood samples obtained before t-PA treatment, at 24 and 72 hours. Results: Serum ferritin levels before t-PA infusion correlated to glutamate (r = 0.59, p < 0.001) and interleukin-6 (r = 0.55, p <0.001) levels at baseline, and with glutamate (r = 0.57,p <0.001), interleukin-6 (r = 0.49,p <0.001), metalloproteinase-9 (r = 0.23, p = 0.007) and cellular fibronectin (r = 0.27, p = 0.002) levels measured at 24 hours and glutamate (r = 0.415, p < 0.001), interleukin-6 (r = 0.359, p < 0.001) and metalloproteinase-9 (r = 0.261, p = 0.004) at 72 hours. The association between ferritin and glutamate levels remained after adjustment for confounding factors in generalized linear models. Conclusions: Brain damage associated with increased iron stores in acute ischemic stroke patients treated with iv. tPA may be mediated by mechanisms linked to excitotoxic damage. The role of inflammation, blood brain barrier disruption and oxidative stress in this condition needs further research. PMID:19096131

  8. WDR1 and CLNK gene polymorphisms correlate with serum glucose and high-density lipoprotein levels in Tibetan gout patients.

    Science.gov (United States)

    Lan, Bing; Chen, Peng; Jiri, Mutu; He, Na; Feng, Tian; Liu, Kai; Jin, Tianbo; Kang, Longli

    2016-03-01

    Current evidence suggests heredity and metabolic syndrome contributes to gout progression. Specifically, the WDR1 and CLNK genes may play a role in gout progression in European ancestry populations. However, no studies have focused on Chinese populations, especially Tibetan individuals. This study aims to determine whether variations in these two genes correlate with gout-related indices in Chinese-Tibetan gout patients. Eleven single-nucleotide polymorphisms in the WDR1 and CLNK genes were detected in 319 Chinese-Tibetan gout patients and 318 controls. We used one-way analysis of variance to evaluate the polymorphisms' effects on gout based on mean serum levels of metabolism indicators, such as albumin, glucose (GLU), triglycerides, cholesterol, high-density lipoproteins (HDL-C), creatinine, and uric acid, from fasting venous blood samples. All p values were Bonferroni corrected. Polymorphisms of the WDR1 and CLNK genes affected multiple risk factors for gout development. Significant differences in serum GLU levels were detected between different genotypic groups with WDRI polymorphisms rs4604059 (p = 0.005) and rs12498927 (p = 0.005). In addition, significant differences in serum HDL-C levels were detected between different genotypic groups with the CLNK polymorphism rs2041215 (p = 0.001). Polymorphisms of CLNK also affected levels of albumin, triglycerides, and creatinine. This study is the first to investigate and identify positive correlations between WDR1 and CLNK gene polymorphisms in Chinese-Tibetan populations. Our findings provide significant evidence for the effect of genetic polymorphisms on gout-related factors in Chinese-Tibetan populations.

  9. Simple and sensitive analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Namera, A; Watanabe, T; Yashiki, M; Kojima, T; Urabe, T

    1999-03-01

    A simple method for the analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) is developed. A vial containing a serum sample, 5M sodium hydroxide, and benzylacetone (internal standard) is heated to 70 degrees C, and an SPME fiber is exposed for 30 min in the headspace of the vial. The compounds extracted by the fiber are desorbed by exposing the fiber in the injection port of the GC-MS. The calibration curves show linearity in the range of 0.05-5.0 micrograms/mL for nereistoxin and N-methyl-N-(2-methylthio-1-methylthiomethyl)ethylamine, 0.01-5.0 micrograms/mL for S,S'-dimethyl dihydronereistoxin, and 0.5-10 micrograms/mL for 2-methylthio-1-methylthiomethylethylamine in serum. No interferences are found, and the analysis time is 50 min for one sample. In addition, this proposed method is applied to a patient who attempted suicide by ingesting Padan 4R, a herbicide. Padan 4R contains 4% cartap hydrochloride, which is an analogue of nereistoxin. Nereistoxin and its metabolites are detected in the serum samples collected from the patient during hospitalization. The concentration ranges of nereistoxin in the serum are 0.09-2.69 micrograms/mL.

  10. ZnO nanorod biosensor for highly sensitive detection of specific protein binding

    International Nuclear Information System (INIS)

    Kim, Jin Suk; Park, Won Il; Lee, Chul Ho; Yi, Gyu Chul

    2006-01-01

    We report on the fabrication of electrical biosensors based on functionalized ZnO nanorod surfaces with biotin for highly sensitive detection of biological molecules. Due to the clean interface and easy surface modification, the ZnO nanorod sensors can easily detect streptavidin binding down to a concentration of 25 nM, which is more sensitive than previously reported one-dimensional (1D) nanostructure electrical biosensors. In addition, the unique device structure with a micrometer-scale hole at the center of the ZnO nanorod's conducting channel reduces the leakage current from the aqueous solution, hence enhancing device sensitivity. Moreover, ZnO nanorod field-effect-transistor (FET) sensors may open up opportunities to create many other oxide nanorod electrical sensors for highly sensitive and selective real-time detection of a wide variety of biomolecules.

  11. Graphitic Carbon Nitride Nanosheets-Based Ratiometric Fluorescent Probe for Highly Sensitive Detection of H2O2 and Glucose.

    Science.gov (United States)

    Liu, Jin-Wen; Luo, Ying; Wang, Yu-Min; Duan, Lu-Ying; Jiang, Jian-Hui; Yu, Ru-Qin

    2016-12-14

    Graphitic carbon nitride (g-C 3 N 4 ) nanosheets, an emerging graphene-like carbon-based nanomaterial with high fluorescence and large specific surface areas, hold great potential for biosensor applications. Current g-C 3 N 4 nanosheets based fluorescent biosensors majorly rely on single fluorescent intensity reading through fluorescence quenching interactions between the nanosheets and metal ions. Here we report for the first time the development of a novel g-C 3 N 4 nanosheets-based ratiometric fluorescence sensing strategy for highly sensitive detection of H 2 O 2 and glucose. With o-phenylenediamine (OPD) oxidized by H 2 O 2 in the presence of horseradish peroxidase (HRP), the oxidization product can assemble on the g-C 3 N 4 nanosheets through hydrogen bonding and π-π stacking, which effectively quenches the fluorescence of g-C 3 N 4 while delivering a new emission peak. The ratiometric signal variations enable robust and sensitive detection of H 2 O 2 . On the basis of the glucose converting into H 2 O 2 through the catalysis of glucose oxidase, the g-C 3 N 4 -based ratiometric fluorescence sensing platform is also exploited for glucose assay. The developed strategy is demonstrated to give a detection limit of 50 nM for H 2 O 2 and 0.4 μM for glucose, at the same time, it has been successfully used for glucose levels detection in human serum. This strategy may provide a cost-efficient, robust, and high-throughput platform for detecting various species involving H 2 O 2 -generation reactions for biomedical applications.

  12. Highly Sensitive, Transparent, and Durable Pressure Sensors Based on Sea-Urchin Shaped Metal Nanoparticles.

    Science.gov (United States)

    Lee, Donghwa; Lee, Hyungjin; Jeong, Youngjun; Ahn, Yumi; Nam, Geonik; Lee, Youngu

    2016-11-01

    Highly sensitive, transparent, and durable pressure sensors are fabricated using sea-urchin-shaped metal nanoparticles and insulating polyurethane elastomer. The pressure sensors exhibit outstanding sensitivity (2.46 kPa -1 ), superior optical transmittance (84.8% at 550 nm), fast response/relaxation time (30 ms), and excellent operational durability. In addition, the pressure sensors successfully detect minute movements of human muscles. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. A high sensitivity process variation sensor utilizing sub-threshold operation

    OpenAIRE

    Meterelliyoz, Mesut; Song, Peilin; Stellari, Franco; Kulkarni, Jaydeep P.; Roy, Kaushik

    2008-01-01

    In this paper, we propose a novel low-power, bias-free, high-sensitivity process variation sensor for monitoring random variations in the threshold voltage. The proposed sensor design utilizes the exponential current-voltage relationship of sub-threshold operation thereby improving the sensitivity by 2.3X compared to the above-threshold operation. A test-chip containing 128 PMOS and 128 NMOS devices has been fabri...

  14. A Microneedle Functionalized with Polyethyleneimine and Nanotubes for Highly Sensitive, Label-Free Quantification of DNA

    OpenAIRE

    Saadat-Moghaddam, Darius; Kim, Jong-Hoon

    2017-01-01

    The accurate measure of DNA concentration is necessary for many DNA-based biological applications. However, the current methods are limited in terms of sensitivity, reproducibility, human error, and contamination. Here, we present a microneedle functionalized with polyethyleneimine (PEI) and single-walled carbon nanotubes (SWCNTs) for the highly sensitive quantification of DNA. The microneedle was fabricated using ultraviolet (UV) lithography and anisotropic etching, and then functionalized w...

  15. Serum High-Mobility-Group Box 1 as a Biomarker and a Therapeutic Target during Respiratory Virus Infections.

    Science.gov (United States)

    Patel, Mira C; Shirey, Kari Ann; Boukhvalova, Marina S; Vogel, Stefanie N; Blanco, Jorge C G

    2018-03-13

    Host-derived "danger-associated molecular patterns" (DAMPs) contribute to innate immune responses and serve as markers of disease progression and severity for inflammatory and infectious diseases. There is accumulating evidence that generation of DAMPs such as oxidized phospholipids and high-mobility-group box 1 (HMGB1) during influenza virus infection leads to acute lung injury (ALI). Treatment of influenza virus-infected mice and cotton rats with the Toll-like receptor 4 (TLR4) antagonist Eritoran blocked DAMP accumulation and ameliorated influenza virus-induced ALI. However, changes in systemic HMGB1 kinetics during the course of influenza virus infection in animal models and humans have yet to establish an association of HMGB1 release with influenza virus infection. To this end, we used the cotton rat model that is permissive to nonadapted strains of influenza A and B viruses, respiratory syncytial virus (RSV), and human rhinoviruses (HRVs). Serum HMGB1 levels were measured by an enzyme-linked immunosorbent assay (ELISA) prior to infection until day 14 or 18 post-infection. Infection with either influenza A or B virus resulted in a robust increase in serum HMGB1 levels that decreased by days 14 to 18. Inoculation with the live attenuated vaccine FluMist resulted in HMGB1 levels that were significantly lower than those with infection with live influenza viruses. RSV and HRVs showed profiles of serum HMGB1 induction that were consistent with their replication and degree of lung pathology in cotton rats. We further showed that therapeutic treatment with Eritoran of cotton rats infected with influenza B virus significantly blunted serum HMGB1 levels and improved lung pathology, without inhibiting virus replication. These findings support the use of drugs that block HMGB1 to combat influenza virus-induced ALI. IMPORTANCE Influenza virus is a common infectious agent causing serious seasonal epidemics, and there is urgent need to develop an alternative treatment

  16. [Expression of high mobility group box-1 in the lung tissue and serum of patients with pulmonary tuberculosis].

    Science.gov (United States)

    Yang, Xiao-min; Yang, Hua

    2013-07-01

    To explore the expression of high mobility group box-1 (HMGB1) in the lung tissue and serum of patients with pulmonary tuberculosis and to explore its relationship with tumor necrosis factor (TNF)-α and interleukin(IL)-1β. Sixty samples of lung tissues were obtained from patients with pulmonary tuberculosis who had underwent pneumonectomy in Department of Chest Surgery, First Affiliated Hospital of Zunyi Medical College from June 2010 to December 2011. At the same period, 40 normal lung samples were also obtained from patients with pulmonary contusion and lung cancer by surgical resections as the control group. The mRNA expressions of HMGB1 was detected by reverse transcription-polymerase chain reaction (RT-PCR), and the protein level of HMGB1 was measured by immunohistochemical staining of tissue microarrays in lung tissue. Blood samples were taken from 89 patients with active pulmonary tuberculosis (pulmonary tuberculosis group), including hematogenous disseminated pulmonary tuberculosis (type II) in 35 cases and secondary pulmonary tuberculosis (type III) in 54 cases, and 50 healthy volunteers (control group). Furthermore, the 54 patients with secondary pulmonary tuberculosis were divided into different subgroups according to cavity formation and the lung fields involved: patients without lung cavity (35 cases) vs those with lung cavity (19 cases), patients with involvement of pulmonary tuberculosis (69 ± 29) was significantly higher than that in normal lung tissue (22 ± 12) (t = 2.389, P pulmonary tuberculosis (786 ± 86) was significantly higher than that in normal lung tissue (202 ± 60) (t = 3.872, P pulmonary tuberculosis group were (5.0 ± 3.2) µg/L, (118 ± 77) ng/L and (33 ± 20) ng/L, respectively, which were significantly higher than those in the control group [(1.7 ± 1.0) µg/L, (40 ± 11) ng/L and (18 ± 12) ng/L, respectively], the respective t values being -0.928, 4.268 and 11.064, all P pulmonary tuberculosis, the serum concentration of HMGB

  17. Impact of high glucose concentration on aspirin-induced acetylation of human serum albumin: An in vitro study

    Directory of Open Access Journals (Sweden)

    Francesco Finamore

    2014-06-01

    Full Text Available Aspirin (ASA plays a key role in protecting high risk cardiovascular patients from ischaemic events. The modifications underlying its effects are the results of the trans-acetylation that occurs between ASA and the amino groups made up of lysine and N-terminal residues. ASA's effects have also been demonstrated on several plasma proteins, including human serum albumin (HSA. However, its beneficial effects seem to be lower in diabetic patients, suggesting that protein glycation may impair ASA's acetylation process. Using immunoblotting and mass spectrometry, this study characterized the degree of HSA acetylation mediated by ASA in vitro, as well as the impact of high glucose concentrations. Glycation's influence on HSA acetylation might impair the latter's biological functions, leading to a potential failure of ASA to prevent cardiovascular complications in diabetes.

  18. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  19. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China); Zhang, Kai [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhu, Peiping; Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China and Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-02-15

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

  20. High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

    International Nuclear Information System (INIS)

    Wu, Zhao; Gao, Kun; Chen, Jian; Wang, Dajiang; Wang, Shenghao; Chen, Heng; Bao, Yuan; Shao, Qigang; Wang, Zhili; Zhang, Kai; Zhu, Peiping; Wu, Ziyu

    2015-01-01

    Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations

  1. Development of a high sensitivity pinhole type gamma camera using semiconductors for low dose rate fields

    Science.gov (United States)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo

    2018-06-01

    We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.

  2. Effects of Diet High in Palmitoleic Acid on Serum Lipid Levels and Metabolism

    Science.gov (United States)

    2000-07-01

    that originated in Australia, has taining substantial amounts of olive oil, a become a primary export crop from Ha- substance with high concentrations...monounsaturated fatty the pilot study, although the high-dose macadamia nut acids, enriched with avocado , and a high-carbohydrate diet. AmdClinNutr

  3. Glucagon-Like Peptide-1 Secreting Cell Function as well as Production of Inflammatory Reactive Oxygen Species Is Differently Regulated by Glycated Serum and High Levels of Glucose

    Directory of Open Access Journals (Sweden)

    Alessandra Puddu

    2014-01-01

    Full Text Available Glucagon-like peptide-1 (GLP-1, an intestinal hormone contributing to glucose homeostasis, is synthesized by proglucagon and secreted from intestinal neuroendocrine cells in response to nutrients. GLP-1 secretion is impaired in type 2 diabetes patients. Here, we aimed at investigating whether diabetic toxic products (glycated serum (GS or high levels of glucose (HG may affect viability, function, and insulin sensitivity of the GLP-1 secreting cell line GLUTag. Cells were cultured for 5 days in presence or absence of different dilutions of GS or HG. GS and HG (alone or in combination increased reactive oxygen species (ROS production and upregulated proglucagon mRNA expression as compared to control medium. Only HG increased total production and release of active GLP-1, while GS alone abrogated secretion of active GLP-1. HG-mediated effects were associated with the increased cell content of the prohormone convertase 1/3 (PC 1/3, while GS alone downregulated this enzyme. HG upregulated Glucokinase (GK and downregulated SYNTHAXIN-1. GS abrogated SYNTHAXIN-1 and SNAP-25. Finally, high doses of GS alone or in combination with HG reduced insulin-mediated IRS-1 phosphorylation. In conclusion, we showed that GS and HG might regulate different pathways of GLP-1 production in diabetes, directly altering the function of neuroendocrine cells secreting this hormone.