WorldWideScience

Sample records for serum glucose blood

  1. The relationship between serum cortisol, adrenaline, blood glucose ...

    African Journals Online (AJOL)

    The relationship between serum cortisol, adrenaline, blood glucose and lipid profile of ..... stressor, neurons with cell bodies in the paraventricular nuclei of the ... metabolic changes that contribute to heart disease and other health problems21.

  2. The relationship between serum cortisol, adrenaline, blood glucose ...

    African Journals Online (AJOL)

    Background: Stress is an extremely adaptive phenomenon in human beings and cortisol is a known stress hormone. Examination has been described as a naturalistic stressor capable of affecting human health. Objectives: To estimate the relationship between serum cortisol, adrenaline, fasting blood glucose (FBG) and ...

  3. Effects of different levels of coconut fiber on blood glucose, serum insulin and minerals in rats.

    Science.gov (United States)

    Sindurani, J A; Rajamohan, T

    2000-01-01

    The effect of neutral detergent fiber (NDF) from coconut kernel (Cocos nucifera L) in rats fed 5%, 15% and 30% level on the concentration of blood glucose, serum insulin and excretion of minerals was studied. Increase in the intake of fiber resulted in significant decrease in the level of blood glucose and serum insulin. Faecal excretion of Cu, Cr, Mn, Mg, Zn and Ca was found to increase in rats fed different levels of coconut fiber when compared to fiber free group. The result of the present investigation suggest that inclusion of coconut fiber in the diet results in significant hypoglycemic action.

  4. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  5. Clinical significance of determination of serum leptin, insulin levels and blood sugar in pregnant women with glucose metabolism disturbances

    International Nuclear Information System (INIS)

    Yu Suqing; Li Yusheng; Wang Lin; Chu Kaiqiu

    2006-01-01

    Objective: To investigate the changes of serum leptin, insulin levels and blood sugar contents in pregnant women with gestational glucose metabolism disturbances. Methods: Fasting and 3h after oral 50g glucose serum levels of leptin were measured with RIA in 36 pregnant women with glucose metabolism disturbances (gestational diabetes mellitus or gestational impaired glucose tolerance) and 34 controls. Also, fasting serum insulin levels (with CLIA) and blood sugar contents 1h after oral 50 glucose (with glucose oxidase method) were determined in all these subjects. Results: 1. Serum levels of leptin in pregnant women with glucose metabolism disturbances were 14.9 ± 4.3 μg/L (vs controls 9.8 ± 1.7 μg/L, P<0.01). 2. The serum levels of insulin and 1 h post - 50g glucose blood sugar contents in pregnant women with glucose metabolism disturbances were 12.9±4.3mU/L and 11.0±1.4mmol/L respectively, which were both significantly positively correlated with the serum leptin levels (r=0.835, r=0.758 respectively) (vs levels in controls: 8.45±3.0mU/L and 7.84±1.3mmol/L). Conclusion: Elevation of fasting serum levels of leptin was demonstrated in pregnant women with glucose metabolism disturbances and the level of leptin was positively correlated with that of insulin and blood sugar. (authors)

  6. The Impact of opium consumption on blood glucose, serum lipids and blood pressure, and related mechanisms

    Directory of Open Access Journals (Sweden)

    Hamid Najafipour

    2016-10-01

    Full Text Available AbstractAim: Substance abuse has become a universal crisisin our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (77 articles. Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms, but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption.

  7. The Impact of Opium Consumption on Blood Glucose, Serum Lipids and Blood Pressure, and Related Mechanisms

    Science.gov (United States)

    Najafipour, Hamid; Beik, Ahmad

    2016-01-01

    Aim: Substance abuse has become a universal crisis in our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (78 articles). Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms), but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption. PMID:27790151

  8. The Impact of Opium Consumption on Blood Glucose, Serum Lipids and Blood Pressure, and Related Mechanisms.

    Science.gov (United States)

    Najafipour, Hamid; Beik, Ahmad

    2016-01-01

    Aim: Substance abuse has become a universal crisis in our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (78 articles). Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms), but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption.

  9. Guar gum effects on food intake, blood serum lipids and glucose levels of Wistar rats.

    Science.gov (United States)

    Frias, A C; Sgarbieri, V C

    1998-01-01

    The effects of guar gum derived from the endosperm of Cyamopsis tetragonoloba (75% soluble fiber, 7.6% insoluble fiber, 2.16% crude protein, 0.78% total lipids, 0.54% ash and 9.55% moisture) on food intake, levels of blood serum cholesterol, triacylglycerols, glucose and LDL and HDL-cholesterol were studied. The effects of guar gum on indices of protein absorption and utilization were also investigated. Diets containing 0%, 10% and 20% (w/w) guar gum or 10% and 20% cellulose powder (reference) were fed to normal rats for 60 days. The rats fed the guar gum diets showed significantly (p Guar gum decreased blood serum glucose only during the first month of the experiment, and no changes in the indices of protein absorption and utilization were found. The guar gum caused a 10% increase in the small intestine length and a 25% retardation in the intestinal transit. The results of this research suggested that guar gum could potentially be effective in the treatment of hypercholesterolemia and obesity in humans.

  10. Study of the Effect of Garlic on Serum Lipids and Blood Glucose Levels in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    M Afkhami - Ardekani

    2005-04-01

    Full Text Available Introduction: Hyperlipidemia and diabetes are common risk factors for ischemic heart disease, which is the main cause of mortality in diabetic patients. Strict control of blood glucose and other risk factors in diabetics has led to prevention of complications. Garlic has received particular attention for control of blood glucose and decrease in blood lipid levels. At present, several studies have been carried out in order to prove advantages of garlic. Methods: In this study, effects of garsin (a derivative of garlic present in our country on serum lipids and blood glucose levels in diabetes mellitus type 2 patients was observed. Forty-five type 2 diabetics who had hyperlipidemia were selected. These patients were kept on treatment with 3 tablets of Garsin / day for 4 weeks. Serum lipids and blood glucose levels were measured prior to and at the end of treatment. Results: Relationship between sex and response to treatment in this study was meaningful, such that Gsarsin led to decrease in LDL-C and increase in HDL in females. Conclusion: Therefore, Garsin can be used as an adjunct to treatment in diabetes type 2 patients with hyperlipidemia.

  11. Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase.

    Science.gov (United States)

    Kucherenko, I S; Soldatkin, O O; Lagarde, F; Jaffrezic-Renault, N; Dzyadevych, S V; Soldatkin, A P

    2015-11-01

    Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor determines glucose concentration in the sample. Platinum disk electrodes were used as amperometric transducers. Glucose oxidase and hexokinase were co-immobilized via cross-linking with BSA by glutaraldehyde and served as a biorecognition element of the biosensor. The biosensor work at different concentrations of CK substrates (ADP and creatine phosphate) was investigated; optimal concentration of ADP was 1mM, and creatine phosphate - 10 mM. The reproducibility of the biosensor responses to glucose, ATP and CK during a day was tested (relative standard deviation of 15 responses to glucose was 2%, to ATP - 6%, to CK - 7-18% depending on concentration of the CK). Total time of CK analysis was 10 min. The measurements of creatine kinase in blood serum samples were carried out (at 20-fold sample dilution). Twentyfold dilution of serum samples was chosen as optimal for CK determination. The biosensor could distinguish healthy and ill people and evaluate the level of CK increase. Thus, the biosensor can be used as a test-system for CK analysis in blood serum or serve as a component of multibiosensors for determination of important blood substances. Determination of activity of other kinases by the developed biosensor is also possible for research purposes. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. High dose flaxseed oil supplementation may affect fasting blood serum glucose management in human type 2 diabetics.

    Science.gov (United States)

    Barre, Douglas E; Mizier-Barre, Kazimiera A; Griscti, Odette; Hafez, Kevin

    2008-01-01

    Type 2 diabetes is characterized partially by elevated fasting blood serum glucose and insulin concentrations and the percentage of hemoglobin as HbA1c. It was hypothesized that each of blood glucose and its co-factors insulin and HbA1c and would show a more favorable profile as the result of flaxseed oil supplementation. Patients were recruited at random from a population pool responding to a recruitment advertisement in the local newspaper and 2 area physicians. Completing the trial were 10 flaxseed oil males, 8 flaxseed oil females, 8 safflower (placebo) oil males and 6 safflower oil females. Patients visited on two pre-treatment occasions each three months apart (visits 1 and 2). At visit 2 subjects were randomly assigned in double blind fashion and in equal gender numbers to take flaxseed oil or safflower oil for three further months until visit 3. Oil consumption in both groups was approximately 10 g/d. ALA intake in the intervention group was approximately 5.5 g/d. Power was 0.80 to see a difference of 1 mmol of glucose /L using 12 subjects per group with a p < 0.05. Flaxseed oil had no impact on fasting blood serum glucose, insulin or HbA1c levels. It is concluded that high doses of flaxseed oil have no effect on glycemic control in type 2 diabetics.

  13. Effects of xylitol on blood glucose, glucose tolerance, serum insulin and lipid profile in a type 2 diabetes model of rats.

    Science.gov (United States)

    Islam, Md Shahidul; Indrajit, Mitesh

    2012-01-01

    The present study was conducted to examine the antidiabetic effects of xylitol in a type 2 diabetes rat model. Six-week-old male Sprague-Dawley rats were randomly divided into 3 groups: normal control (NC), diabetic control (DBC) and xylitol (XYL). Diabetes was induced only in the DBC and XYL animal groups by feeding them a 10% fructose solution for 2 weeks followed by an injection (i.p.) of streptozotocin (40 mg/kg body weight). One week after the streptozotocin injection, the animals with a nonfasting blood glucose level of >300 mg/dl were considered to be diabetic. The XYL group was fed further with a 10% xylitol solution, whereas the NC and DBC groups were supplied with normal drinking water. After 5 weeks of intervention, food and fluid intake, body weight, blood glucose, serum fructosamine and most of the serum lipids were significantly decreased, and serum insulin concentration and glucose tolerance ability was significantly increased in the XYL group compared to the DBC group. Liver weight, liver glycogen and serum triglycerides were not influenced by feeding with xylitol. The data of this study suggest that xylitol can be used not only as a sugar substitute but also as a supplement to antidiabetic food and other food products. Copyright © 2012 S. Karger AG, Basel.

  14. Correlation of blood glucose, serum chemerin and insulin resistance with NAFLD in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Zhang, Zhengjun; Wang, Jijun; Wang, Hongmei

    2018-03-01

    Non-alcoholic fatty liver disease (NAFLD) is a form of clinical syndrome characterized by the fatty degeneration in liver histology and should be further investigated. The aim of the study was to investigate the effects of blood glucose, serum chemerin and insulin resistance on non-alcoholic fatty liver disease (NAFLD) in patients with type 2 diabetes mellitus to provide a basis for the prevention and treatment thereof. In total, 300 patients with type 2 diabetes mellitus treated and admitted into the Endocrinology Department of our hospital from June 2015 to June 2017 were enrolled and divided into the simple type 2 diabetes mellitus (group A) and concurrent NAFLD (group B) groups. The sex, age, body mass index (BMI), blood pressure, blood biochemical indexes and chemerin level were compared between the two groups. The patients in group B were further divided into the mild fatty liver (group B1), moderate fatty liver (group B2) and severe fatty liver (group B3) groups. The sex, age, BMI blood pressure, blood biochemical indexes and chemerin level were also compared among the three groups. Finally, the risk factors of type 2 diabetes mellitus complicated by NAFLD were analyzed via logistic regression. The BMI, fasting plasma glucose (FPG), 2 h post-prandial plasma glucose (2hPG), triglyceride (TG), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-c), alanine aminotransferase (ALT), fasting insulin (FINS), homeostasis model assessment of insulin resistance (HOMA-IR) and HOMA-β indexes and serum chemerin level in group B were significantly higher than those in group A (Pdiabetes mellitus complicated by NAFLD is closely associated with severe glucose-lipid metabolism disorder and insulin resistance, and BMI, FPG, TC, LDL-c, FINS, HOMA-IR and chemerin constitute risk factors of concurrent NAFLD.

  15. The Effects of Capparis Spinosa Hydroalcoholic Extract on Blood Glucose and Lipids Serum in Diabetic and Normal Male Rats

    Directory of Open Access Journals (Sweden)

    M Negahdarizadeh

    2011-06-01

    Full Text Available Introduction & Objective: Diabetes mellitus is one of the most common endocrine disorders in the world which affects glucose metabolism in the body. Diabetes mellitus is due to lack of insulin secretion and/or failure in insulin action. Researches conducted in the last few decades on plants have reported anti-diabetic properties for some herbs and their traditional use for diabetes treatment. Capparis spinosa is one of these herbs which are used as an anti-diabetic treatment in tribal medicine. The objective of the present study was to examine the anti-diabetic effects of Capparis spinosa on blood glucose and serum lipids in streptozotocin induced diabetes in male rats. Materials & Methods: In this experimental study conducted at Yasouj University of Medical Sciences in 2010, five groups of animals were selected. Three groups out of five were administered with intraperitoneal injection of streptozotocin to become diabetic. Group I were fed normal diet. Group II of animals received 20 mg/kg/day Capparis spinosa extract. Group III received no treatment (diabetic control and animals of groups IV and V were treated with capparis spinosa fruit extract 20 and 30 mg/kg body weight respectively for three weeks. Blood glucose, triglycerides, total cholesterol, LDL, HDL and body weight were measured in all animals. The collected data was analyzed by the SPSS software using one-way ANOVA. Results: Treatment with the 30 mg/kg/body weight of capparis spinosa fruit extract showed a significant decrease in blood glucose, triglycerides, total cholesterol and LDL, and a significant increase in HDL level. In addition, administration of 20 mg/kg/body weight of capparis spinosa extract decreased blood glucose and lipid levels in diabetic rats. Conclusion: It can be concluded that the oral administration of capparis spinosa extract at the dose of 30 mg/kg/body weight has glucose and lipids lowering activity in diabetic rats.

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... can often lower your blood glucose level by exercising. However, if your blood glucose is above 240 ... ketones. If you have ketones, do not exercise. Exercising when ketones are present may make your blood ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... We Are Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get ... the technical term for high blood glucose (blood sugar). High blood glucose happens when the body has ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... how often you should check and what your blood glucose levels should be. Checking your blood and then treating ... I Treat Hyperglycemia? You can often lower your blood glucose level by exercising. However, if your blood glucose is ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Carbohydrate Counting Make Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type ... Checking Your Blood Glucose A1C and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon ...

  3. Red palm oil supplementation does not increase blood glucose or serum lipids levels in Wistar rats with different thyroid status.

    Science.gov (United States)

    Rauchová, H; Vokurková, M; Pavelka, S; Vaněčková, I; Tribulová, N; Soukup, T

    2018-01-05

    Red palm oil (RPO) is a rich natural source of antioxidant vitamins, namely carotenes, tocopherols and tocotrienols. However, it contains approximately 50 % saturated fatty acids the regular consumption of which could negatively modify lipid profile. The aim of our study was to test whether 7 weeks of RPO supplementation (1 g/kg body weight/day) would affect blood glucose and lipid metabolism in adult male Wistar rats with altered thyroid status. We induced hypothyroidism and hyperthyroidism in rats by oral administration of either methimazole or mixture of thyroid hormones. Different thyroid status (EU - euthyroid, HY - hypothyroid and HT - hyperthyroid) was characterized by different serum thyroid hormones levels (total and free thyroxine and triiodothyronine), changes in the activity of a marker enzyme of thyroid status - liver mitochondrial glycerol-3-phosphate dehydrogenase, and altered absolute and relative heart weights. Fasting blood glucose levels were higher in HT rats in comparison with EU and HY rats, but the changes caused by RPO supplementation were not significant. The achievement of the HY status significantly increased serum levels of total cholesterol, as well as with high-density lipoprotein-cholesterol and low-density lipoprotein-cholesterol: 2.43+/-0.15, 1.48+/-0.09, 0.89+/-0.08 mmol/l, compared to EU: 1.14+/-0.06, 0.77+/-0.06, 0.34+/-0.05 mmol/l and HT: 1.01+/-0.06, 0.69+/-0.04, 0.20+/-0.03 mmol/l, respectively. RPO supplementation did not increase significantly levels of blood lipids but tended to increase glutathione levels in the liver. In conclusion, RPO supplementation did not induce the presumed deterioration of glucose and lipid metabolism in rats with three well-characterized alterations in thyroid status.

  4. [Blood glucose self monitoring].

    Science.gov (United States)

    Wascher, Thomas C; Stechemesser, Lars

    2016-04-01

    Self monitoring of blood glucose contributes to the integrated management of diabetes mellitus. It, thus, should be available for all patients with diabetes mellitus type-1 and type-2. Self monitoring of blood glucose improves patients safety, quality of life and glucose control. The current article represents the recommendations of the Austrian Diabetes Association for the use of blood glucose self monitoring according to current scientific evidence.

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose High levels of sugar in the urine Frequent urination Increased thirst Part of managing your ... glucose is above 240 mg/dl, check your urine for ketones. If you have ketones, do not ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page ... and-how-tos, . In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood ...

  8. Blood Glucose Determination

    DEFF Research Database (Denmark)

    Lippi, Giuseppe; Nybo, Mads; Cadamuro, Janne

    2018-01-01

    The measurement of fasting plasma glucose may be biased by a time-dependent decrease of glucose in blood tubes, mainly attributable to blood cell metabolism when glycolysis is not rapidly inhibited or blood cells cannot be rapidly separated from plasma. Although glycolysis inhibitors such as sodium...

  9. Serum glucose, cholesterol and blood pressure levels in Japanese type 1 and 2 diabetic patients: BioBank Japan.

    Science.gov (United States)

    Yokomichi, Hiroshi; Nagai, Akiko; Hirata, Makoto; Kiyohara, Yutaka; Muto, Kaori; Ninomiya, Toshiharu; Matsuda, Koichi; Kamatani, Yoichiro; Tamakoshi, Akiko; Kubo, Michiaki; Nakamura, Yusuke; Yamagata, Zentaro

    2017-03-01

    Evidence of characteristics of Japanese patients with diabetes from a large-scale population is necessary. Few studies have compared glycaemic controls, complications and comorbidities between type 1 and 2 diabetic patients. This paper focuses on illustrating a clinical picture of Japanese diabetic patients and comparing glycaemic control and prognoses between type 1 and 2 diabetes using multi-institutional data. The BioBank Japan Project enrolled adult type 1 and 2 diabetic patients between fiscal years 2003 and 2007. We have presented characteristics, controls of serum glucose, cholesterol and blood pressure, prevalence of complications and comorbidities and survival curves. We have also shown glycaemic controls according to various individual profiles of diabetic patients. A total of 558 type 1 diabetic patients and 30,834 type 2 diabetic patients participated in this study. The mean glycated haemoglobin A1c was higher in type 1 diabetes than in type 2 diabetes. In the type 1 diabetic patients, the glycated haemoglobin A1c had no consistent trend according to age and body mass index. The Kaplan-Meier estimates represented a longer survival time from baseline with type 1 diabetes than with type 2 diabetes. Compared with type 1 diabetic patients, type 2 diabetic patients had double the prevalence of macrovascular complications. This work has revealed detailed plasma glucose levels of type 1 and 2 diabetic patients according to age, body mass index, blood pressure, serum cholesterol levels and smoking and drinking habits. Our data have also shown that the prognosis is worse for type 2 diabetes than for type 1 diabetes in Japan. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Clinical Practice Guidelines Patient Education Materials Scientific Sessions Journals for Professionals Professional Books Patient Access to Research ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. How ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Day in the Life of Diabetes Famous People Working to Stop Diabetes Common Terms Diabetes Statistics Infographics ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... your blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. ... to detect hyperglycemia so you can treat it early — before it gets worse. If you're new ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Email: Sign Up Thank you for signing up ' + ' '); $('.survey-form').show(); }, success: function (data) { $('#survey-errors').remove(); $('. ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for ... is checking your blood glucose often. Ask your doctor how often you should ... associated with hyperglycemia. How Do I Treat Hyperglycemia? ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication ... Learning at Camp Find a Camp Fundraising Events Step Out Walk to Stop Diabetes Tour de Cure ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... EXPO Volunteer Opportunities Sponsorship and Exhibit Opportunities Camp ... when ketones are present may make your blood glucose level go even higher. You'll need to work with your doctor ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... someone new is diagnosed. Diabetes causes more deaths a year than breast cancer and AIDS combined. Your gift today will help ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia ( ... compact USB drives that can carry a person's full medical record for use in an emergency. How ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events Advocacy News Call ... Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia (High ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose level go even higher. You'll need to work with your doctor to find the ... lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness of breath Breath ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... Living With Diabetes Recently Diagnosed Treatment & Care Complications Health ... EXPOs Awareness Programs Wellness Lives Here Become a Member American ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Chat Closed engagement en -- Have Type 2 Diabetes? - 2017-03-lwt2d-en.html Have Type 2 Diabetes? ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Research & Practice Ways to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease ... than planned or exercised less than planned. You have stress from an illness, such as a cold or flu. You have ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... around 4:00 a.m. to 5:00 a.m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  2. Low Blood Glucose (Hypoglycemia)

    Science.gov (United States)

    ... 24 hours after the activity. Drinking too much alcohol without enough food Alcohol makes it harder for your body to keep ... t eaten in a while. The effects of alcohol can also keep you from feeling the ... able to eat as much or keep food down, which can cause low blood glucose. Learn ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  4. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... are below 100 mg/dL before meals and fasting and are less than 140 mg/dL two hours after meals. People with diabetes should consult their doctor or health care provider to set appropriate blood glucose goals. ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... Pinterest Youtube Instagram Diabetes Stops Here Blog Online Community Site ... Day Prediabetes My Health Advisor Tools to Know Your Risk Diabetes Basics ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ... de Cure Women's Series Do-It-Yourself Fundraising Become a Volunteer American Diabetes Month® American Diabetes Association ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term ... body can't use insulin properly. What Causes Hyperglycemia? A number of things can cause hyperglycemia: If ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You At Risk? Diabetes Basics Living with Diabetes Food & Fitness In My Community Advocacy Research & Practice Ways to Give Close Are You at Risk? Home ... work with your doctor to find the safest way for you to lower your blood glucose ... down on the amount of food you eat might also help. Work with your ...

  9. Blood glucose response to pea fiber

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    Two new fiber types, pea fiber (PF) and sugar beet fiber (BF), were compared with wheat bran (WB) to investigate the effect on postprandial blood glucose and serum insulin responses in normal subjects. The control meal consisted of 150 g ground beef mixed with 50 g glucose and 20 g lactulose. Onl...

  10. Direct determination of glucose, lactate and triglycerides in blood serum by a tunable quantum cascade laser-based mid-IR sensor

    Science.gov (United States)

    Brandstetter, M.; Volgger, L.; Genner, A.; Jungbauer, C.; Lendl, B.

    2013-02-01

    This work reports on a compact sensor for fast and reagent-free point-of-care determination of glucose, lactate and triglycerides in blood serum based on a tunable (1030-1230 cm-1) external-cavity quantum cascade laser (EC-QCL). For simple and robust operation a single beam set-up was designed and only thermoelectric cooling was used for the employed laser and detector. Full computer control of analysis including liquid handling and data analysis facilitated routine measurements. A high optical pathlength (>100 μm) is a prerequisite for robust measurements in clinical practice. Hence, the optimum optical pathlength for transmission measurements in aqueous solution was considered in theory and experiment. The experimentally determined maximum signal-to-noise ratio (SNR) was around 140 μm for the QCL blood sensor and around 50 μm for a standard FT-IR spectrometer employing a liquid nitrogen cooled mercury cadmium telluride (MCT) detector. A single absorption spectrum was used to calculate the analyte concentrations simultaneously by using a partial-least-squares (PLS) regression analysis. Glucose was determined in blood serum with a prediction error (RMSEP) of 6.9 mg/dl and triglycerides with an error of cross-validation (RMSECV) of 17.5 mg/dl in a set of 42 different patients. In spiked serum samples the lactate concentration could be determined with an RMSECV of 8.9 mg/dl.

  11. Assessment risk of osteoporosis in Chinese people: relationship among body mass index, serum lipid profiles, blood glucose, and bone mineral density

    Directory of Open Access Journals (Sweden)

    Cui RT

    2016-07-01

    Full Text Available Rongtao Cui,1 Lin Zhou,2 Zuohong Li,2 Qing Li,2 Zhiming Qi,2 Junyong Zhang3 1Department of Orthopedic and Trauma Surgery, Surgical Research, Duisburg-Essen University Hospital, Essen, Germany; 2Department of Orthopedics, Dalian Central Hospital, Dalian, 3Department of Gastroenterology, Shandong Provincial Hospital, Jinan, People’s Republic of China Objective: The aim of our study was to investigate the relationship among age, sex, body mass index (BMI, serum lipid profiles, blood glucose (BG, and bone mineral density (BMD, making an assessment of the risk of osteoporosis.Materials and methods: A total of 1,035 male and 3,953 female healthy volunteers (aged 41–95 years were recruited by an open invitation. The basic information, including age, sex, height, weight, waistline, hipline, menstrual cycle, and medical history, were collected by a questionnaire survey and physical examination. Serum lipid profiles, BG, postprandial blood glucose, and glycosylated hemoglobin were obtained after 12 hours fasting. BMD in lumbar spine was measured by dual-energy X-ray absorptiometry scanning.Results: The age-adjusted BMD in females was significantly lower than in males. With aging, greater differences of BMD distribution exist in elderly females than in males (P<0.001, and the fastigium of bone mass loss was in the age range from 51 to 55 in females and from 61 to 65 years in males. After adjustment for sex, there were significant differences in BMD among BMI-stratified groups in both males and females. The subjects with a BMI of <18.5 had a higher incidence of osteoporosis than BMI ≥18.5 in both sexes. BMD in type 2 diabetes mellitus with a BG of >7.0 mmol/L was lower than in people with BG of ≤7.0 mmol/L (P<0.001. People with serum high-density lipoprotein cholesterol levels of ≥1.56 mmol/L had a greater prevalence of osteoporosis compared with high-density lipoprotein cholesterol ≤1.55 mmol/L. Logistic regression with odds ratios showed that

  12. Daily consumption of banana marginally improves blood glucose and lipid profile in hypercholesterolemic subjects and increases serum adiponectin in type 2 diabetic patients.

    Science.gov (United States)

    Cressey, Ratchada; Kumsaiyai, Warunee; Mangklabruks, Ampika

    2014-12-01

    In this study, we explored the effects of consumption of banana in thirty hypercholesterolemic and fifteen type 2 diabetic subjects. They were given a daily dose of 250 or 500 grams of banana for breakfast for 12 weeks. Fasting serum lipid, glucose and insulin levels were measured initially as well as every 4 weeks. Daily consumption of banana significantly lowered fasting blood glucose (from 99 ± 7.7 to 92 ± 6.9 and 102 ± 7.3 to 92 ± 5.7 mg x dL(-1) (p profile in diabetic patients were not statistically significant, but for plasma levels of adiponectin, there were significantly increased (from 37.5 ± 9.36 to 48.8 ± 7.38 ngnml1, p consumption of banana (@ 250 g/day) is harmless both in diabetic and hypercholesterolemic volunteers and marginally beneficial to the later.

  13. Is Low Blood Glucose (Hypoglycemia) Dangerous?

    Science.gov (United States)

    ... pills. In general, hypoglycemia is defined as a blood glucose level below 70 mg/dl. Low blood glucose is ... glucose. Always carry carbohydrate foods for treatment. Check blood glucose levels again in 15 minutes, and repeat treatment if ...

  14. Precision and costs of techniques for self-monitoring of serum glucose levels.

    OpenAIRE

    Chiasson, J. L.; Morrisset, R.; Hamet, P.

    1984-01-01

    The poor correlation between serum and urine glucose measurements has led to the development of new techniques for monitoring the blood glucose level in diabetic patients. Either a nurse or the patient can perform these tests, which involve spreading a single drop of blood onto a reagent strip. A colour change that is proportional to the serum glucose level can be read visually or with a reflectance meter. Evaluated against simultaneous serum glucose levels determined by the hospital biochemi...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for energy. When your body breaks down fats, waste products called ketones are produced. Your body cannot ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers ... updated, this is the "take-you-by-the-hand" guide that will become a trusted friend and ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Superfoods Non-starchy Vegetables Grains and Starchy Vegetables Fats Alcohol What Can I Drink? Fruit Dairy Food ... glucose for fuel, so your body breaks down fats to use for energy. When your body breaks ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your best bet is to practice good diabetes management and learn to detect hyperglycemia so you can ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood ... For Parents & Kids Safe at School Everyday Life Children and Type 2 Diabetes Know Your Rights Employment ...

  20. Current concepts in blood glucose monitoring

    OpenAIRE

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on t...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... What Can I Drink? Fruit Dairy Food Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Student Resources History of Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths ... blood, which can lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... sugar in the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood ... have a medical ID with them at all times. In the event of a severe hypoglycemic episode, ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes ... Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  5. Current concepts in blood glucose monitoring.

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-12-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  6. Current concepts in blood glucose monitoring

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827

  7. Current concepts in blood glucose monitoring

    Directory of Open Access Journals (Sweden)

    Kranti Shreesh Khadilkar

    2013-01-01

    Full Text Available Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG and continuous glucose monitoring system (CGMS. It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  8. Blood Glucose Levels and Problem Behavior

    Science.gov (United States)

    Valdovinos, Maria G.; Weyand, David

    2006-01-01

    The relationship between varying blood glucose levels and problem behavior during daily scheduled activities was examined. The effects that varying blood glucose levels had on problem behavior during daily scheduled activities were examined. Prior research has shown that differing blood glucose levels can affect behavior and mood. Results of this…

  9. The Correlation of Hemoglobin A1c to Blood Glucose

    OpenAIRE

    Sikaris, Ken

    2009-01-01

    The understanding that hemoglobin A1c (HbA1c) represents the average blood glucose level of patients over the previous 120 days underlies the current management of diabetes. Even in making such a statement, we speak of “average blood glucose” as though “blood glucose” were itself a simple idea. When we consider all the blood glucose forms—arterial versus venous versus capillary, whole blood versus serum versus fluoride-preserved plasma, fasting versus nonfasting—we can start to see that this ...

  10. Why control blood glucose levels?

    Science.gov (United States)

    Rossini, A A

    1976-03-01

    The controversy as to the relationship between the degree of control of diabetes and the progression of the complications of the disease has not been solved. However, in this review, various studies suggesting a relationship between the metabolic abnormality and the diabetic complications are examined. The disadvantages of the uncontrolled diabetes mellitus can be divided into two major categories-short-term and long-term. The short-term disadvantages of controlled diabetes mellitus include the following: (1) ketoacidosis and hyperosmolar coma; (2) intracellular dehydration; (3) electrolyte imbalance; (4) decreased phagocytosis; (5) immunologic and lymphocyte activity; (6) impairment of wound healing; and (7) abnormality of lipids. The long-term disadvantages of uncontrolled diabetes melitus include the following: (1) nephropathy; (2) neuropathy; (3) retinopathy; (4) cataract formation; (5) effect on perinatal mortality; (6) complications of vascular disease; and (7) the evaluation of various clinical studies suggesting the relationship of elevated blood glucose levels and complications of diabetes mellitus. It is suggested that until the question of control can absolutely be resolved, the recommendation is that the blood glucose levels should be controlled as close to the normal as possible.

  11. Effect of Petiveria alliacea Leaves Extract in Decreasing Serum Level of Blood Glucose Level Through Activation of AMPK-α1 in Diabetes Mellitus Rat Models

    Directory of Open Access Journals (Sweden)

    Arifa Mustika

    2017-03-01

    Full Text Available Singawalang (Petiveria alliaceae is a medicinal herb that is used traditionally as folk medicine for various diseases. The plant has been used as an antidiabetic agent in Indonesian society. Until now, the effect and mechanism of action of Petiveria alliaceae as antidiabetic agent is not clear. The aim of the study was to determine the effect of Petiveria alliaceae to blood glucose level and to identify expression of AMPK-α1 in rat liver. The research was experimental study with randomized and was conducted at Laboratory Pharmacology and Therapy, and Laboratory Patology Anatomy, Faculty of Medicine, Universitas Airlangga, on April until August 2015. Twenty five male rats were injected by Streptozotocin to create diabetic rat models and randomly divided into 5 groups. The group 1, 2 and 3 are treatment groups that were given the ethanol extract of Petiveria alliaceae at dose 90 mg/kgbw, 180 mg/kgbw, and 360 mg/kgbw, orally, once daily for fourteen days. The fourth group is a negative control who were given distilled water and the fifth group is a positive control who were given metformin at dose 150 mg/kgbw. On the 15th day, blood glucose level were measured by glucometer and the rats were sacrificed to collect the liver. Expression of AMPK-α1 were assessed by immunohistochemistry. Data were analyzed by ANAVA and Wilcoxon (α=0,05. The results have been showed that there were significant differences in glucose blood level between negative control with the group were given the extract at dose 90 mg/kgbw, 360 mg/kgbw and positive control, between dose 180 mg/kgbw with dose 360 mg/kgbw and positive control. A significant differences of expression of AMPK-α1 showed between dose 180 mg/kgbw with dose 360 mg/kgbw and positive control. The conclusion of this study was the extract ethanol of Singawalang leaves reduce blood glucose level in diabetes mellitus rat models through increase in the expression of AMPK-α1.

  12. Changes of glucose utilization by erythrocytes, lactic acid concentration in the serum and blood cells, and haematocrit value during one hour rest after maximal effort in individuals differing in physical efficiency.

    Science.gov (United States)

    Tomasik, M

    1982-01-01

    Glucose utilization by the erythrocytes, lactic acid concentration in the blood and erythrocytes, and haematocrit value were determined before exercise and during one hour rest following maximal exercise in 97 individuals of either sex differing in physical efficiency. In the investigations reported by the author individuals with strikingly high physical fitness performed maximal work one-third greater than that performed by individuals with medium fitness. The serum concentration of lactic acid was in all individuals above the resting value still after 60 minutes of rest. On the other hand, this concentration returned to the normal level in the erythrocytes but only in individuals with strikingly high efficiency. Glucose utilization by the erythrocytes during the restitution period was highest immediately after the exercise in all studied individuals and showed a tendency for more rapid return to resting values again in individuals with highest efficiency. The investigation of very efficient individuals repeated twice demonstrated greater utilization of glucose by the erythrocytes at the time of greater maximal exercise. This was associated with greater lactic acid concentration in the serum and erythrocytes throughout the whole one-hour rest period. The observed facts suggest an active participation of erythrocytes in the process of adaptation of the organism to exercise.

  13. Ex vivo changes in blood glucose levels seldom change blood glucose control algorithm recommendations

    NARCIS (Netherlands)

    de Groene, L.; Harmsen, R. E.; Binnekade, J. M.; Spronk, P. E.; Schultz, M. J.

    2010-01-01

    Background. Hyperglycemia and glycemic variabilities are associated with adverse outcomes in critically ill patients. Blood glucose control with insulin mandates an adequate and precise assessment of blood glucose levels. Blood glucose levels, however, can change ex vivo after sampling. The aim of

  14. Serum glucose and lipid levels in alloxan-induced diabetic rats ...

    African Journals Online (AJOL)

    Effect of Aloe barbadensis Miller juice extract on serum glucose and lipids in alloxan-induced diabetic rats was investigated. Diabetes was induced by intraperitoneal injection of 150mg/kg alloxan in 5% solution. Diabetes was confirmed 72 hours after alloxan injection, if fasting blood glucose (FBG) was equal to or greater ...

  15. Serum glucose and liver glycogen in gamma irradiated rats

    International Nuclear Information System (INIS)

    Ahlersova, E.; Ahlers, I.; Molcanova, A.

    1988-01-01

    Overnight fasted male rats of Wistar strain were irradiated with single whole-body doses of 4.78-7.17-9.57 and 14.35 Gy of gamma rays. After decapitation at intervals 1-28 d (4.78 and 7.17 Gy), 1-7 d (9.57 Gy) and 1-3 d (14.35 Gy) glucose concentration in serum and glycogen concentration in liver of irradiated and non-irradiated animals were determined. The higher was radiation dose the more expressive extent and depth of changes (hyperglycemia, accumulation of glycogen) occured. Blood glucose and liver glycogen may serve as a reliable and dose-dependent biological indicators of metabolic changes in irradiated rats. (author)

  16. Comparison of the effects of flaxseed oil and sunflower seed oil consumption on serum glucose, lipid profile, blood pressure, and lipid peroxidation in patients with metabolic syndrome.

    Science.gov (United States)

    Akrami, Atefeh; Nikaein, Farzad; Babajafari, Siavash; Faghih, Shiva; Yarmohammadi, Hassan

    Metabolic syndrome (MetSyn) increases the risk of type II diabetes and morbidity and mortality due to cardiovascular diseases. Flaxseed oil (FO), as a functional food, is one of the major vegetal sources of essential omega-3 fatty acids. This study aimed to compare the effects of consumption of FO and sunflower seed oil (SO) on lipid peroxidation and other symptoms of MetSyn. This randomized controlled interventional trial was conducted on 60 volunteers aged 30 to 60 years who were diagnosed with MetSyn in Shiraz, Iran. The participants who fulfilled the inclusion criteria were randomly assigned to SO (n = 30, receiving 25 mL/d SO) and FO (n = 30, receiving 25 ml/d FO) groups using block randomization. The diets were identical for all the participants. Blood pressure (BP), serum lipid, fasting blood sugar, and malondialdehyde were measured at baseline and at the end of week 7. The results showed no significant difference between the 2 groups regarding blood lipid levels and fasting blood sugar at the end of the study. However, significant reductions in total cholesterol, low-density lipoprotein cholesterol (5.6% in FO and 10.8% in SO), and triglyceride levels were seen within each group after treatment with FO and SO (P < .05). Nonetheless, between-group changes were significant (<0.05) for systolic BP (mean [±standard deviation {SD}] changes were -14.0 ± 22.41 in the FO group [P = .004] and 0.92 ± 8.70 in the SO group [P = .594]) and diastolic BP (mean [±SD] changes were -4.26 ± 7.44 in the FO group [P = .007] and 1.30 ± 6.91 in the SO group [P = .344]), but marginally significant (P = .053) for malondialdehyde level (mean [±SD] changes were -1.29 ± 1.48 in the FO group [P < .001] and -0.52 ± 1.34 in the SO group [P = .52]). A significant decrease in weight was also found in both groups. However, waist circumference decreased significantly only in the FO group at the end of the study (P < .05). Our results indicated

  17. Glucose metabolism in diabetic blood vessels

    International Nuclear Information System (INIS)

    Brown, B.J.; Crass, M.F. III

    1986-01-01

    Since glycolysis appears to be coupled to active ion transport in vascular smooth muscle, alterations in glucose metabolism may contribute to cellular dysfunction and angiopathy in diabetes. Uptake and utilization of glucose were studied in perfused blood vessels in which pulsatile flow and perfusion pressure were similar to those measured directly in vivo. Thoracic aortae isolated from 8-wk alloxan diabetic (D) and nondiabetic control rabbits were cannulated, tethered, and perfused with oxygenated buffer containing 7 or 25 mM glucose and tracer amounts of glucose-U -14 C. Norepinephrine (NE) (10 -6 M) and/or insulin (I) (150 μU/ml) and albumin (0.2%) were added. NE-induced tension development increased glucose uptake 39% and 14 CO 2 and lactate production 2.3-fold. With 7 mM glucose, marked decreases in glucose uptake (74%), 14 CO 2 (68%), lactate (30%), total tissue glycogen (75%), and tissue phospholipids (70%) were observed in D. Addition of I or elevation of exogenous glucose to 25 mM normalized glucose uptake, but had differential effects on the pattern of substrate utilization. Thus, in D, there was a marked depression of vascular glucose metabolism that was partially reversed by addition of low concentrations of insulin or D levels of glucose

  18. Reduced brain/serum glucose ratios predict cerebral metabolic distress and mortality after severe brain injury.

    Science.gov (United States)

    Kurtz, Pedro; Claassen, Jan; Schmidt, J Michael; Helbok, Raimund; Hanafy, Khalid A; Presciutti, Mary; Lantigua, Hector; Connolly, E Sander; Lee, Kiwon; Badjatia, Neeraj; Mayer, Stephan A

    2013-12-01

    The brain is dependent on glucose to meet its energy demands. We sought to evaluate the potential importance of impaired glucose transport by assessing the relationship between brain/serum glucose ratios, cerebral metabolic distress, and mortality after severe brain injury. We studied 46 consecutive comatose patients with subarachnoid or intracerebral hemorrhage, traumatic brain injury, or cardiac arrest who underwent cerebral microdialysis and intracranial pressure monitoring. Continuous insulin infusion was used to maintain target serum glucose levels of 80-120 mg/dL (4.4-6.7 mmol/L). General linear models of logistic function utilizing generalized estimating equations were used to relate predictors of cerebral metabolic distress (defined as a lactate/pyruvate ratio [LPR] ≥ 40) and mortality. A total of 5,187 neuromonitoring hours over 300 days were analyzed. Mean serum glucose was 133 mg/dL (7.4 mmol/L). The median brain/serum glucose ratio, calculated hourly, was substantially lower (0.12) than the expected normal ratio of 0.40 (brain 2.0 and serum 5.0 mmol/L). In addition to low cerebral perfusion pressure (P = 0.05) and baseline Glasgow Coma Scale score (P brain/serum glucose ratios below the median of 0.12 were independently associated with an increased risk of metabolic distress (adjusted OR = 1.4 [1.2-1.7], P brain/serum glucose ratios were also independently associated with in-hospital mortality (adjusted OR = 6.7 [1.2-38.9], P brain/serum glucose ratios, consistent with impaired glucose transport across the blood brain barrier, are associated with cerebral metabolic distress and increased mortality after severe brain injury.

  19. Blood glucose in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj

    2009-01-01

    of infarcts. For a number of years, tight glycemic control has been regarded as beneficial in critically illness, but recent research has been unable to support this notion. The only completed randomized study on glucose-lowering therapy in stroke has failed to demonstrate effect, and concerns relating...

  20. Alterations of serum concentrations of thyroid hormones and sex hormone-binding globulin, nuclear binding of tri-iodothyronine and thyroid hormone-stimulated cellular uptake of oxygen and glucose in mononuclear blood cells from patients with non-thyroidal illness

    DEFF Research Database (Denmark)

    Kvetny, J; Matzen, L

    1990-01-01

    Nuclear tri-iodothyronine (T3) binding and thyroid hormone-stimulated oxygen consumption and glucose uptake were examined in mononuclear blood cells from patients with non-thyroidal illness (NTI) in which serum T3 was significantly (P less than 0.05) depressed (0.62 +/- 0.12 (S.D.) nmol/l) compared...

  1. Effect of Camel Milk's Supplementation on Serum Glucose Levels ...

    African Journals Online (AJOL)

    Keywords: Camel Milk, Serum glucose, Lipid profile, Diabetes. INTRODUCTION. Diabetes is ... all products of Randox Laboratories, Switzerland. Fresh camel milk samples .... Abbott, R.D., Wilson, P.W., Kannel, W.B. and. Castelli, W.P. (1988).

  2. Umbilical cord blood glucose levels in full-term newborns

    Directory of Open Access Journals (Sweden)

    A. L. Karpova

    2014-01-01

    Full Text Available The purpose of the investigation was to determine the umbilical cord venous blood level of glucose in full-term newborns and its relationship to the mode of delivery. The investigation included 102 full-term newborn infants, including 33 and 69 babies born via cesar-ean and vaginal delivery, respectively. Umbilical cord serum glucose levels were determined by the glucose oxidase test using a Sap-phire-400 biochemical analyzer. In healthy full-term newborns, the mean umbilical cord blood glucose levels were 4,29±0,88 mmol/1 (minimum, 2,9 mmol/1 and maximum, 5,9 mmol/1. In the babies born via cesarean delivery, the umbilical cord blood concentration of glucose was ascertained to be significantly lower than in those born vaginally (3,84+0,71 mmol/1 versus 4,51+0,87 mmol/1; /><0,0001. Abdominal delivery can be apparently considered to be a risk factor for hypoglycemia in neonatal infants.

  3. 成人身体成分与血脂、血糖关系的探讨%Analysis of the relationship between body composition and fasting serum lipids, fasting blood glucose in adult

    Institute of Scientific and Technical Information of China (English)

    李秋桂; 姬芳勤

    2014-01-01

    目的:分析成人身体成分与血脂、血糖指标之间的关系方法选择成年体检者490名,排除严重心脑肝肾疾病,肿瘤患者,急性炎症患者及长期服药者等。通过Biospace InBody 220人体成分分析仪对身体水分、蛋白质、无机盐、体脂肪、体重、骨骼肌肉量、体质指数、体脂百分比、腰臀脂肪比等指标进行测定。同时测定空腹血糖、血脂指标。所有指标的测定均由我院医护人员经过统一培训后进行操作。结果男女性别年龄无差异(p>0.05)。除体脂肪外,男女性别间身体水分、蛋白质、无机盐、体重、骨骼肌肉量、体质指数、体脂百分比、腰臀脂肪比均有显著差异(均p<0.001)。蛋白质、体脂肪、体重、骨骼肌肉量、体质指数、体脂百分比、腰臀脂肪比与空腹血糖呈正相关(均p<0.05)。身体水分、蛋白质、无机盐、体脂肪、体重、骨骼肌肉量、体质指数、体脂百分比、腰臀脂肪比均可对血脂(总胆固醇、甘油三酯)产生影响(均p<0.05)。剔除性别因素后,对身体成分与血糖、血脂各指标进行偏相关分析,体脂肪、体重、体质指数、体脂百分比、腰臀脂肪比仍然与血糖、总胆固醇、甘油三酯呈正相关(均p<0.05)。结论成人身体成分与血糖、血脂指标密切相关。通过身体成分的分析,可尽早预防代谢相关性疾病。%Objective To analyze the relationship between body composition and fasting serum lipids, fasting blood glucose in adult. Methods Select 490 adult, eliminate the subjects who has the serious cardiovascular diseases, liver diseases , kidney diseases, cancer and the subjects with acute inflammation and long term medication etc. Body moisture, protein, inorganic salt, fat, skeletal muscle weight, body mass index, percentage of body fat, waist and hip fat ratio was determined by Biospace InBody 220. Measure the

  4. Random blood glucose testing in dental practice

    DEFF Research Database (Denmark)

    Barasch, Andrei; Safford, Monika M; Qvist, Vibeke

    2012-01-01

    The prevalence of diabetes mellitus (DM) has been increasing. Instances of patients' not having received a diagnosis have been reported widely, as have instances of poor control of DM or prediabetes among patient's who have the disease. These facts indicate that blood glucose screening is needed....

  5. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  6. Screening of gingival crevicular blood glucose and capillary finger blood glucose in the diagnosis of diabetes

    Directory of Open Access Journals (Sweden)

    Alka S Waghmare

    2011-01-01

    Full Text Available Aim: The study aimed at obtaining glucose readings using gingival crevicular blood (GCB to screen for undiagnosed diabetes during routine dental visits. Materials and Methods: The present study included 50 patients who were divided into two groups, i.e. Group A and Group B, based on bleeding on probing at the site of collection of GCB. Group A participants had blood collected from sites having adequate bleeding on probing, whereas Group B participants had blood collected from sites with little bleeding on probing. GCB and capillary finger-stick blood (CFB] glucose readings were obtained using a self-monitoring glucometer. Statistical Analysis: Correlations between both the samples were done using Pearson′s correlation. Results: Group A patients′ correlations between GCB and CFB glucose readings were high, whereas in Group B patients, correlations between glucose readings were low. Conclusion: GCB can be an excellent source for screening diabetes during routine dental visits.

  7. Relationship between blood glucose levels and muscle strength in ...

    African Journals Online (AJOL)

    Relationship between blood glucose levels and muscle strength in rural South African ... African Journal for Physical Activity and Health Sciences ... left handgrip and fasting blood glucose after adjusting for age, gender and family history of ...

  8. Blood Glucose, Insulin and Inorganic Phosphorus in Healthy and Ketotic Dairy Cows after Intravenous Infusion of Glucose Solution

    Directory of Open Access Journals (Sweden)

    Radojica Djoković

    2009-01-01

    Full Text Available The aim of the present study was to determine the degree of blood glucose utilization by peripheral tissue on the basis of changes in blood concentrations of glucose, insulin and inorganic phosphorus in healthy (n = 10 and ketotic cows (n = 10 after intravenous infusion of glucose solution. Blood samples were taken in both groups of examined cows at the following time intervals: just before (time 0 and 30, 60, 120, 180 and 240 min after intravenous infusion of a total of 500 ml of 50% of glucose solution. Glucose and insulin blood serum values in both groups of cows increased significantly within 30 and 60 min of the experiment (p p p < 0.05 in the blood value of inorganic phosphorus in ketotic cows compared to the healthy ones. This is linked with the active entry of glucose into the glucolytic pathway of peripheral tissues. It can thus be concluded that there is a higher degree of blood glucose utilization by peripheral tissues in ketotic cows.

  9. Daidzin decreases blood glucose and lipid in streptozotocin ...

    African Journals Online (AJOL)

    hyperglycemic mice and improved oral glucose tolerance. The serum and ... Inhibition of α-glucosidase and stimulation of glucose consumption by muscles may account for ..... induced production of tumor necrosis factor-alpha and fibrinolysis ...

  10. Serum Growth Hormone and Glucose Levels in Acute Exercise and in the Recovery Period in Athletes

    Directory of Open Access Journals (Sweden)

    Elma Kučukalić-Selimović

    2006-05-01

    Full Text Available Growth hormone exerts several metabolic effects, including effects on proteins, fats and carbohydrates. Among the many metabolic activities of GH, two contradictory actions were described: acute and early insulin-like activity and chronic and late anti-insulin like activity also called diabetogenic activity. A dramatic increase in plasma concentration of GH was found during endurance exercise, but its role during exercise is not well known. According to its metabolic effects a possible role of growth hormone may be in maintenance of glucose level during exercise. The aim of this study was to analyze dynamics of changes in GH and glucose levels during acute workload and in the recovery period, in a group of well trained athletes. All the subjects exercised for 30 minutes on cycle ergometer in sitting position (work intensity 50% of VO2 max, RPM 60/min. Serum GH concentrations were measured by IRMA (immunoradiometric assays method in blood samples obtained at rest and 6-min intervals during exercise, and 15-min intervals during recovery period. Serum glucose levels were determined by standard enzymatic method glucose oxidase (GOD PAP at the same intervals. There were no correlations between serum GH and glucose levels either during exercise or in the recovery period. There were no differences between glucose levels during exercise, so we can not exclude possible role of GH in glucose concentration maintenance.

  11. Blood glucose control and monitoring in the critically ill

    NARCIS (Netherlands)

    van Hooijdonk, R.T.M.

    2015-01-01

    This thesis deals with blood glucose control and blood glucose monitoring in intensive care unit (ICU) patients: two important aspects of care for and monitoring of critically ill patients. While the precise targets of blood glucose control in ICU patients remain a matter of debate, currently many,

  12. Work related stress and blood glucose levels.

    Science.gov (United States)

    Sancini, A; Ricci, S; Tomei, F; Sacco, C; Pacchiarotti, A; Nardone, N; Ricci, P; Suppi, A; De Cesare, D P; Anzelmo, V; Giubilati, R; Pimpinella, B; Rosati, M V; Tomei, G

    2017-01-01

    The aim of the study is to evaluate work-related subjective stress in a group of workers on a major Italian company in the field of healthcare through the administration of a valid "questionnaire-tool indicator" (HSE Indicator Tool), and to analyze any correlation between stress levels taken from questionnaire scores and blood glucose values. We studied a final sample consisting of 241 subjects with different tasks. The HSE questionnaire - made up of 35 items (divided into 7 organizational dimensions) with 5 possible answers - has been distributed to all the subjects in occasion of the health surveillance examinations provided by law. The questionnaire was then analyzed using its specific software to process the results related to the 7 dimensions. These results were compared using the Pearson correlation and multiple linear regression with the blood glucose values obtained from each subject. From the analysis of the data the following areas resulted critical, in other words linked to an intermediate (yellow area) or high (red area) condition of stress: sustain from managers, sustain from colleagues, quality of relationships and professional changes. A significant positive correlation (p work stress can be statistically associated with increased levels of blood glucose.

  13. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    Science.gov (United States)

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  14. Efficacy of Tribulus Terrestris Extract on the Serum Glucose and Lipids of Women with Diabetes Mellitus

    Science.gov (United States)

    Samani, Nasrin Babadai; Jokar, Azam; Soveid, Mahmood; Heydari, Mojtaba; Mosavat, Seyed Hamdollah

    2016-01-01

    Background: Considering folkloric use of Tribulus terrestris (T. terrestris) in diabetes and proven anti-hyperglycemic and anti-hyperlipidemic effects of T. terrestris in animal studies, we aimed to evaluate the efficacy of the hydro alcoholic extract of T. terrestris on the serum glucose and lipid profile of women with diabetes mellitus. Methods: Ninety-eight diabetic women were randomly allocated to receive the T. terrestris (1000 mg/day) or placebo for three months. The patients were evaluated in terms of the fasting blood glucose, 2-hour postprandial glucose, glycosylated hemoglobin and lipid profile. Results: T. terrestris showed a significant blood glucose lowering effect in diabetic women compared to placebo (Pterrestris group was significantly reduced compared with placebo, while no significant effect was observed in the triglyceride and high-density lipoprotein levels. Conclusion: This study showed preliminary promising hypoglycemic effect of T. terrestris in diabetic women. PMID:27840471

  15. Efficacy of Tribulus Terrestris Extract on the Serum Glucose and Lipids of Women with Diabetes Mellitus.

    Science.gov (United States)

    Samani, Nasrin Babadai; Jokar, Azam; Soveid, Mahmood; Heydari, Mojtaba; Mosavat, Seyed Hamdollah

    2016-05-01

    Considering folkloric use of Tribulus terrestris (T. terrestris) in diabetes and proven anti-hyperglycemic and anti-hyperlipidemic effects of T. terrestris in animal studies, we aimed to evaluate the efficacy of the hydro alcoholic extract of T. terrestris on the serum glucose and lipid profile of women with diabetes mellitus. Ninety-eight diabetic women were randomly allocated to receive the T. terrestris (1000 mg/day) or placebo for three months. The patients were evaluated in terms of the fasting blood glucose, 2-hour postprandial glucose, glycosylated hemoglobin and lipid profile. T. terrestris showed a significant blood glucose lowering effect in diabetic women compared to placebo (Pterrestris group was significantly reduced compared with placebo, while no significant effect was observed in the triglyceride and high-density lipoprotein levels. This study showed preliminary promising hypoglycemic effect of T. terrestris in diabetic women.

  16. Blood-Brain Glucose Transfer: Repression in Chronic Hyperglycemia

    Science.gov (United States)

    Gjedde, Albert; Crone, Christian

    1981-10-01

    Diabetic patients with increased plasma glucose concentrations may develop cerebral symptoms of hypoglycemia when their plasma glucose is rapidly lowered to normal concentrations. The symptoms may indicate insufficient transport of glucose from blood to brain. In rats with chronic hyperglycemia the maximum glucose transport capacity of the blood-brain barrier decreased from 400 to 290 micromoles per 100 grams per minute. When plasma glucose was lowered to normal values, the glucose transport rate into brain was 20 percent below normal. This suggests that repressive changes of the glucose transport mechanism occur in brain endothelial cells in response to increased plasma glucose.

  17. Discussion on the establishment of blood glucose fluctuation animal models

    OpenAIRE

    Chun-Liu Gai; Jing-Ru Zhao; Xiao-Long Chen

    2014-01-01

    AIM: To provide the experimental basis for the in vivo study of blood glucose fluctuation injury mechanism, through intraperitoneal injection of glucose to establish blood glucose fluctuation animal models and to simulate blood glucose fluctuation of patients with diabetes.METHODS: Rats were randomly divided into four groups: normal control group(NC), normal fluctuation group(NF), diabetes mellitus group(DM)and diabetes fluctuation group(DF). Diabetic models were induced through intraperitone...

  18. Effect of Camel Milk's Supplementation on Serum Glucose Levels ...

    African Journals Online (AJOL)

    Cases of diabetes are on the rise in almost every population and epidemiological studies suggest that without proper prevention and control measures, prevalence of the disease will continue to increase globally. The aim of the current study was to investigate the effect of camel milk supplementation on serum glucose, lipid ...

  19. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    Science.gov (United States)

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Fasting serum glucose and glycosylated hemoglobin level in obesity.

    Science.gov (United States)

    Das, R K; Nessa, A; Hossain, M A; Siddiqui, N I; Hussain, M A

    2014-04-01

    Obesity is a condition in which the body fat stores are increased to an extent which impairs health and leads to serious health consequences. The amount of body fat is difficult to measure directly, and is usually determined from an indirect measure - the body mass index (BMI). Increased BMI in obese persons is directly associated with an increase in metabolic disease, such as type 2 diabetes mellitus. This Analytical cross sectional study was undertaken to assess the relation between obesity and glycemic control of body by measuring fasting serum glucose and glycosylated hemoglobin. This study was carried out in the Department of Physiology, Mymensingh Medical College, Mymensingh from 1st July 2011 to 30th June 2012 on 120 equally divided male and female persons within the age range of 25 to 55 years. Age more than 55 years and less than 25 years and diagnosed case of Hypothyroidism, Cushing's syndrome, polycystic ovary, Antipsychotic drug user and regular steroid users were excluded. Non probability purposive type of sampling technique was used for selecting the study subjects. Measurement of body mass index was done as per procedure. Fasting serum glucose was estimated by glucose oxidase method and Glycosylated hemoglobin by Boronate Affinity method. Statistical analysis was done by SPSS (version 17.0). Data were expressed as Mean±SE and statistical significance of difference among the groups were calculated by unpaired student's 't' test and Pearson's correlation coefficient tests were done as applicable. The Mean±SE of fasting serum glucose was significant at 1% level (P value obese group of BMI. There was no significant difference of glycosylated hemoglobin level between control and study groups. But there was positive correlation within each group. Fasting serum glucose also showed a bit stronger positive correlation with BMI. Both obese male and female persons showed higher levels of fasting serum glucose and glycosylated hemoglobin. The observed positive

  1. A Survey On Ionic And Metabolite Factors Of Blood Serum In Kutum (Rutilus frisii kutum

    Directory of Open Access Journals (Sweden)

    Afkhami Majid

    2014-10-01

    Full Text Available In this study, ionic parameters and metabolite factors (cholesterol, total protein, and glucose of serum and their interrelationships were detected in 48 specimens of kutum (Rutilus frisii kutum captured during spawning migration. Blood sampling was conducted by cutting the caudal peduncle of each sample, and blood was collected into heparinized and sterile capillary glass tubes.

  2. Variations of blood glucose in cancer patients during chemotherapy

    African Journals Online (AJOL)

    2016-05-23

    May 23, 2016 ... Purpose: The aim of this study was to analyze the blood glucose (BG) variations in cancer patients .... cancer, brain tumor, cervical cancer, and leukemia were the ... excess glucose supply for these glucose‑hungry cells and it.

  3. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    -day workshop on the design, use and evaluation of prediction methods for blood glucose concentration was held at the Johannes Kepler University Linz, Austria. One intention of the workshop was to bring together experts working in various fields on the same topic, in order to shed light from different angles...... discussions which allowed to receive direct feedback from the point of view of different disciplines. This book is based on the contributions of that workshop and is intended to convey an overview of the different aspects involved in the prediction. The individual chapters are based on the presentations given...... in the process of writing this book: All authors for their individual contributions, all reviewers of the book chapters, Daniela Hummer for the entire organization of the workshop, Boris Tasevski for helping with the typesetting, Florian Reiterer for his help editing the book, as well as Oliver Jackson and Karin...

  4. Serum Insulin, Glucose, Indices of Insulin Resistance, and Risk of Lung Cancer.

    Science.gov (United States)

    Argirion, Ilona; Weinstein, Stephanie J; Männistö, Satu; Albanes, Demetrius; Mondul, Alison M

    2017-10-01

    Background: Although insulin may increase the risk of some cancers, few studies have examined fasting serum insulin and lung cancer risk. Methods: We examined serum insulin, glucose, and indices of insulin resistance [insulin:glucose molar ratio and homeostasis model assessment of insulin resistance (HOMA-IR)] and lung cancer risk using a case-cohort study within the Alpha-Tocopherol, Beta-Carotene Cancer Prevention Study of Finnish men. A total of 196 cases and 395 subcohort members were included. Insulin and glucose were measured in fasting serum collected 5 to 12 years before diagnosis. Cox proportional hazards models were utilized to estimate the relative risk of lung cancer. Results: The average time between blood collection and lung cancer was 9.6 years. Fasting serum insulin levels were 8.7% higher in subcohort members than cases. After multivariable adjustment, men in the fourth quartile of insulin had a significantly higher risk of lung cancer than those in the first quartile [HR = 2.10; 95% confidence interval (CI), 1.12-3.94]. A similar relationship was seen with HOMA-IR (HR = 1.83; 95% CI, 0.99-3.38). Risk was not strongly associated with glucose or the insulin:glucose molar ratio ( P trend = 0.55 and P trend = 0.27, respectively). Conclusions: Higher fasting serum insulin concentrations, as well as the presence of insulin resistance, appear to be associated with an elevated risk of lung cancer development. Impact: Although insulin is hypothesized to increase risk of some cancers, insulin and lung cancer remain understudied. Higher insulin levels and insulin resistance were associated with increased lung cancer risk. Although smoking cessation is the best method of lung cancer prevention, other lifestyle changes that affect insulin concentrations and sensitivity may reduce lung cancer risk. Cancer Epidemiol Biomarkers Prev; 26(10); 1519-24. ©2017 AACR . ©2017 American Association for Cancer Research.

  5. Recommending blood glucose monitors, a pharmacy perspective.

    Science.gov (United States)

    Carter, Alan

    2007-03-01

    Selection of what blood glucose monitoring system to utilize has become an issue for physicians, diabetes educators, pharmacists, and patients. The field of competing makes and models of blood glucose monitoring systems has become crowded, with manufacturers touting improvements in accuracy, ease of use/alternate site options, stored results capacity, software evaluation tools, and/or price point. Personal interviews of 12 pharmacists from community and academic practice settings about monitor preference, as well as results from a national survey of pharmacist recommendations, were compared to actual wholesale sales data to estimate the impact of such recommendations on final monitor selection by the patient. Accu-Chek monitors were recommended 34.65% of the time and represented 28.58% of sales, with a success rate of 82.48% of being the monitor selected. OneTouch monitors had 27.72% of recommendations but represented 31.43% of sales, indicating possible patient brand loyalty or formulary preference for that product. FreeStyle(R) monitors came in third for pharmacist recommendations and were selected by the patient 61.68% of the time when recommended. The category of "other monitor" choices was selected 60.89% of the time by patients given those suggestions. Included in the "other monitor" category was the new disposable monitor marketed as the Sidekick. Based on sales data provided, the Sidekick made up 2.87% of "other monitor" category sales, representing 68% of the "other monitor" segment. While patients frequently follow pharmacist monitoring system suggestions, the ultimate deciding factor is most often the final out-of-pocket cost to the patient. As a result, cost of supplies often becomes the most important determining factor in final monitor selection at the patient level. If the patient cannot afford to perform the recommended daily testing intervals, all other determining factors and suggestions become moot.

  6. Change in blood glucose level in rats after immobilization

    Science.gov (United States)

    Platonov, R. D.; Baskakova, G. M.; Chepurnov, S. A.

    1981-01-01

    Experiments were carried out on male white rats divided into four groups. In group one the blood glucose level was determined immediately after immobilization. In the other three groups, two hours following immobilization, the blood glucose level was determined every 20 minutes for 3 hours 40 minutes by the glucose oxidase method. Preliminary immobilization for 2 hours removed the increase in the blood glucose caused by the stress reaction. By the 2nd hour of immobilization in the presence of continuing stress, the blood glucose level stabilized and varied within 42 + or - 5.5 and 47 + or - 8.1 mg %. Within 2 hours after the immobilization, the differences in the blood glucose level of the rats from the control groups were statistically insignificant.

  7. Changes in blood glucose and insulin responses to intravenous glucose tolerance tests and blood biochemical values in adult female Japanese black bears (Ursus thibetanus japonicus).

    Science.gov (United States)

    Kamine, Akari; Shimozuru, Michito; Shibata, Haruki; Tsubota, Toshio

    2012-02-01

    The metabolic mechanisms to circannual changes in body mass of bears have yet to be elucidated. We hypothesized that the Japanese black bear (Ursus thibetanus japonicus) has a metabolic mechanism that efficiently converts carbohydrates into body fat by altering insulin sensitivity during the hyperphagic stage before hibernation. To test this hypothesis, we investigated the changes in blood biochemical values and glucose and insulin responses to intravenous glucose tolerance tests (IVGTT) during the active season (August, early and late November). Four, adult, female bears (5-17 years old) were anesthetized with 6 mg/kg TZ (tiletamine HCl and zolazepam HCl) in combination with 0.1 mg/kg acepromazine maleate. The bears were injected intravenously with glucose (0.5 g/kg of body mass), and blood samples were obtained before, at, and intermittently after glucose injection. The basal triglycerides concentration decreased significantly with increase in body mass from August to November. Basal levels of plasma glucose and serum insulin concentrations were not significantly different among groups. The results of IVGTT demonstrated the increased peripheral insulin sensitivity and glucose tolerance in early November. In contrast, peripheral insulin resistance was indicated by the exaggerated insulin response in late November. Our findings suggest that bears shift their glucose and lipid metabolism from the stage of normal activity to the hyperphagic stage in which they show lipogenic-predominant metabolism and accelerate glucose uptake by increasing the peripheral insulin sensitivity.

  8. Correlation between blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients

    Directory of Open Access Journals (Sweden)

    Fildzah Rahman

    2016-06-01

    Full Text Available Diabetes Mellitus (DM is a syndrome in metabolism of carbohydrates which indicated by the increased level of blood glucose and also may increase salivary glucose levels. Oral ulcer has been frequently recognized in diabetic patients, which can be due to increased glucose in oral fluids and immune dysfunction. This study aimed to determine the correlation of blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients. Analytic observational study was carried out through the determination of blood glucose levels just by way of strip using a glucometer and salivary glucose levels with the method "GOD-PAP test enzymatic colorimetric". Oral ulcer was determined in presenting ulcer on 30 patients with DM. The results showed r = 0.228, which is higher salivary glucose levels followed by high levels of blood glucose, and intraoral examination of oral ulcer found in the whole sample and the most location commonly found in buccal mucosa and lingual. It was concluded that there is a correlation between blood glucose levels and salivary glucose levels, and glucose levels affect the occurrence of oral ulcer in patients with DM

  9. Evaluation of blood neutrophil to lymphocyte and platelet to lymphocyte ratios according to plasma glucose status and serum insulin-like growth factor 1 levels in patients with acromegaly.

    Science.gov (United States)

    Üçler, R; Aslan, M; Atmaca, M; Alay, M; Ademoğlu, E N; Gülşen, I

    2016-06-01

    Cardiovascular, respiratory, and cerebrovascular diseases and malignancies are responsible for morbidity and mortality in acromegaly. Also these diseases are associated with chronic inflammation. The neutrophil to lymphocyte ratio (NLR) and platelet to lymphocyte ratio (PLR) are currently gaining interest as new markers of inflammation. Moreover, increased morbidity and mortality are positively correlated with the presence of diabetes and levels of insulin-like growth factor 1 (IGF-1) in acromegaly. The objective of the present study was to investigate the relationship between these markers and acromegaly according to plasma glucose status and serum IGF-1 levels. We retrospectively analyzed data from 61 acromegaly patients who were in a newly diagnosed period (35 male, 26 female; mean age 38.13 ± 13.98). Patients with normal plasma glucose (n = 27), impaired fasting glucose (n = 18), and diabetes mellitus (n = 16) were categorized into three different groups. NLR and PLR were compared between the study groups and were evaluated according to IGF-1 levels. There were no statistically significant differences in NLR and PLR measurements among the study groups (p > 0.05). However, there were significant positive correlations between NLR and IGF-1 levels and between PLR and IGF-1 levels when all patients were evaluated (r = 0.334, p = 0.011 and r = 0.277, p = 0.035, respectively). This is the first report studying the relationship of NLR and PLR with glucose status and IGF-1 levels in acromegaly patients. Our study results suggest that subclinical inflammation may play a role in increased incidence of mortality and morbidity, which depends on uncontrolled IGF-1 levels in patients with acromegaly. © The Author(s) 2015.

  10. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    Many patients were referred to Kololo polyclinic laboratory to have their blood glucose checked because the values obtained on the patients' glucose meter systems did not tally with familiar clinical signs and symptoms. This prompted an experimental set up to check glucose meter systems using a larger number of patients.

  11. Ghrelin Alleviates MDMA-Induced Disturbance of Serum Glucose and Lipids Levels in the Rat

    Directory of Open Access Journals (Sweden)

    Ravieh Golchoobian

    2018-01-01

    Full Text Available Hepatotoxicity is one of the clinically adverse effects of ecstasy (3, 4-methylenedioxymethamphetamine; MDMA consumption. The detoxification tissue, liver, plays a central role in maintaining circulating levels of glucose and lipid. Hypoglycemia and hypotriglyceridemia have been reported due to ecstasy abuse. Ghrelin is a 28-amino-acid peptide secreted predominantly from the stomach. It has been demonstrated that ghrelin has hepatoprotective effects and is able to increase blood glucose concentration. In the current study, we explored the effect of hepatotoxic dose of MDMA and therapeutic use of exogenous ghrelin on the serum levels of glucose and lipids in four groups of rats. MDMA caused a severe and transient reduction in circulating levels of glucose and triglyceride and increased serum LDL. However, cholesterol and HDL levels remained unchanged. Meanwhile, altered hepatic architecture was observed with intracellular vacuolation that may indicate intracellular accumulation of lipid droplets. In addition, following ghrelin administration, the blood sugar levels improved and LDL levels returned to the baseline value, and ghrelin treatment did not improve triglycerides levels. These results showed that MDMA causes hypoglycemia, hypotriglyceridemia, and hyper LDL-cholesterolemia. To our knowledge, this is the first report showing ghrelin administration could improve hypoglycemia and normalize LDL levels induced by MDMA and partially restore hepatic architecture.

  12. Pre-analytical variation in glucose concentration due to atmospheric temperature and clot in blood specimens

    International Nuclear Information System (INIS)

    Butt, T.; Masud, K.; Khan, J.A.; Bhatti, M.S.

    2016-01-01

    Objective: To determine the effect of temperature and contact of clot with serum on laboratory results of glucose concentration in blood. Study Design: Quasi-experimental study. Place and Duration of Study: December 2014 to August 2015 at the laboratory of Shoaib Hospital, Fateh Jang, Attock Pakistan. Material and Methods: Samples were collected for estimation of blood glucose (Random) concentration from patients reporting to the hospital. Blood specimens (n=94) of such volunteers were analyzed for glucose level. Each sample was put up in five tubes. When the blood clotted the serum from tube-1 was analyzed for glucose level within 30 minutes. In tube-2 and tube-3 serum was kept for 24 hours at room temperature and refrigerator temperature respectively before glucose estimation. In tube-4 and tube-5 serum was not separated from clot and kept at room temperature and refrigerator temperature respectively before glucose estimation. The value of tube 1 was taken as reference value for comparison with other parts of the specimen. The equipment used for blood glucose level estimation was semi auto chemistry analyzer (Rayto, China). The kit used for analysis was Glucose - Liquizyme (Germany). Results: The difference between the mean reference value (tube-1) and refrigerated serum without clot (tube-3) was 4.63 mg/100 ml while that of unrefrigerated portion (tube-2) had a difference of 10.68 mg/100 ml. The mean of unrefrigerated (tube-4) and refrigerated (tube-5) portions of serum kept with the clot had difference of 42.05 mg/100 ml and 25.84 mg/100 ml respectively. The fall in the blood glucose level in all (n=94) the samples in the tube number 3 (serum separated and kept at refrigerated temperature) was 4.63 mg/100 ml +- 3.68 (Mean +- SD) and it ranged from 0 to 20 mg/100 ml whereas fall was maximum in the tube number 4 (serum with clotted blood and kept at room temperature) was 42.04 mg/100 ml +- 10.61 (Mean +- SD) and it ranged from 13 to 82 mg/100 ml. The sample in

  13. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  14. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  15. On the suitability of refractometry for the analysis of glucose in blood-derived fluids.

    Science.gov (United States)

    Zirk, K; Poetzschke, H

    2004-07-01

    Refractometry is the determination of the optical refractive index of a substance or a mixture of substances. It is a very sensitive method for the detection and quantification of dissolved analytes, but it is incapable of distinguishing between different analytes. The aim of this investigation was to determine the principle suitability of refractometry for the quantification of glucose (blood sugar) in blood and various blood fluids which can readily be obtained for medical diagnosis, in particular blood plasma, blood serum, and their ultrafiltrates. After the oral intake of freshly dissolved alpha-glucose, the in vivo blood contents of the alpha and beta anomers of glucose were found to be in an at least approximate equilibrium at all times. This observation is a prerequisite for a refractometrical determination of glucose due to the fact that both molecule forms have different refractive index increments. An assessment of the glucose content in untreated blood fluids was not possible, since no suitable relationship to the refractive index was found, most probably due to the influence of the many other substances present in blood on this parameter. However, after removal of certain macromolecules by ultrafiltration, value pairs showed a high level of correlation, providing the nominal molecular weight limit (cut-off) of the ultrafilter used possessed a maximum of 300 kDa. Besides macromolecules, the osmolality of the fluids undergoing measurement also proved to be a considerable interfering factor, particularly when values were outside the normal physiological range between 285 and 293 mmol/L. If a clinical application of this method is to be contemplated it is imperative (1) that blood cells are separated and removed, (2) that macromolecules present in plasma or serum are removed, e.g. by ultrafiltration, and (3) that beyond the results presented the influence of all small molecules other than glucose on the overall refractive index be determined and included in

  16. Changes in serum metabolic hormone levels after glucose infusion during lactation cycles in Holstein cows

    Directory of Open Access Journals (Sweden)

    Aliasghar Chalmeh

    2015-02-01

    Full Text Available Negative energy balance can impair the metabolism of high producing dairy cows and supplying the glucose, as an energy source; can prevent the metabolic disorders in these animals. Hence, we hypothesized that bolus intravenous glucose administration may change the concentrations of metabolic hormones in order to prevent and control of metabolic dysfunctions of dairy cows. Twenty five multiparous Holstein dairy cows were divided to 5 equal groups containing early, mid and late lactations, far-off and close-up dry periods. All cows were received dextrose 50% intravenously at 500 mg/kg, 10 mL/kg/h. Blood samples were collected from all animals prior to and 1, 2, 3 and 4 after dextrose 50% infusion and sera were separated to determine glucose, triiodothyronine (T3, thyroxine (T4, serum free T3 (fT3, free T4 (fT4, cortisol and insulin like growth factor-1 (IGF-1. The decreasing pattern of T3 concentration was detected in all studied animals following intravenous glucose infusion (P<0.05. The significant increasing pattern of T4 levels was seen in early and mid lactation cows after glucose administration (P<0.05. The significant decreasing pattern of IGF-1 was detected in mid and late lactations and far-off dry groups (P<0.05. There were no significant alterations in fT3, fT4 and cortisol concentrations following glucose infusion in all experimental groups. In conclusion, bolus intravenous glucose infusion could influence the metabolic hormones in high producing Holstein dairy cows. Alterations of metabolic hormones following bolus intravenous glucose administration indicated that glucose is an important direct controller of metabolic interactions and responses in dairy cows during different physiological states.

  17. Prospective Study of Fasting Blood Glucose and Intracerebral Hemorrhagic Risk.

    Science.gov (United States)

    Jin, Cheng; Li, Guohong; Rexrode, Kathryn M; Gurol, Mahmut E; Yuan, Xiaodong; Hui, Ying; Ruan, Chunyu; Vaidya, Anand; Wang, Yanxiu; Wu, Shouling; Gao, Xiang

    2018-01-01

    Although diabetes mellitus is an established independent risk factor for ischemic stroke, the association between fasting blood glucose and intracerebral hemorrhage (ICH) is limited and inconsistent. The objective of the current study was to examine the potential impact of long-term fasting blood glucose concentration on subsequent risk of ICH. This prospective study included 96 110 participants of the Kailuan study, living in Kailuan community, Tangshan city, China, who were free of cardiovascular diseases and cancer at baseline (2006). Fasting blood glucose concentration was measured in 2006, 2008, 2010, and 2012. Updated cumulative average fasting blood glucose concentration was used as primary exposure of the current study. Incident ICH from 2006 to 2015 was confirmed by review of medical records. During 817 531 person-years of follow-up, we identified 755 incident ICH cases. The nadir risk of ICH was observed at fasting blood glucose concentration of 5.3 mmol/L. The adjusted hazard ratios and their 95% confidence intervals (CIs) of ICH were 1.59 (95% CI, 1.26-2.02) for diabetes mellitus or fasting blood glucose ≥7.00 mmol/L, 1.31 (95% CI, 1.02-1.69) for impaired fasting blood glucose (fasting blood glucose, 6.10-6.99 mmol/L), 0.98 (95% CI, 0.78-1.22) for fasting blood glucose 5.60 to 6.09 mmol/L, and 2.04 (95% CI, 1.23-3.38) for hypoglycemia (fasting blood glucose, fasting blood glucose 4.00 to 5.59 mmol/L. The results persisted after excluding individuals who used hypoglycemic, aspirin, antihypertensive agents, or anticoagulants, and those with intracerebral hemorrhagic cases occurred in the first 2 years of follow-up. In this large community-based cohort, low (fasting blood glucose concentrations were associated with higher risk of incident ICH, relative to fasting blood glucose concentrations of 4.00 to 6.09 mmol/L. © 2017 American Heart Association, Inc.

  18. Fasting Blood Glucose Levels in Different Haemoglobin Genotypes ...

    African Journals Online (AJOL)

    For the different Hb genotypes (HBAA, HBAS, HBSC and HBSS) the following mean fasting blood glucose levels were obtained respectively: 71.9±8.Omg/dl 73.4±7.4mgldl, 94.7±6.Imgldl and 94.6±5.9mgldl. There was a significant difference between the mean fasting blood glucose concentrations of blood groups O,A,B and ...

  19. Effects of an exopolysaccharide (kefiran) on lipids, blood pressure, blood glucose, and constipation.

    Science.gov (United States)

    Maeda, Hiroaki; Zhu, Xia; Omura, Kazunobu; Suzuki, Shiho; Kitamura, Shinichi

    2004-01-01

    Lactobacillus kefiranofaciens was reported to produce an exopolysaccharide named kefiran. In the present study, we developed a new medium, rice hydrolyzate (RH) medium, for the culture of L. kefiranofaciens. Structural analyses revealed that the exopolysaccharide produced by L. kefiranofaciens from RH medium was composed of a hexasaccharide repeating unit, and essentially identical to the kefiran reported in previous studies. A study on the effects of kefiran in animals demonstrated that kefiran significantly suppressed increase of blood pressure and reduced the serum cholesterol levels in SHRSP/Hos rats when subjects consumed excessive dietary cholesterol. Kefiran supplementation demonstrated the ability to significantly lower blood glucose in KKAy mice. In addition, the administration of kefiran in constipated SD rats caused an obvious improvement in the levels of fecal moisture and wet weights of feces. These results suggest that kefiran could be used as a functional food to prevent some commonly occurring diseases.

  20. Using LSTMs to learn physiological models of blood glucose behavior.

    Science.gov (United States)

    Mirshekarian, Sadegh; Bunescu, Razvan; Marling, Cindy; Schwartz, Frank

    2017-07-01

    For people with type 1 diabetes, good blood glucose control is essential to keeping serious disease complications at bay. This entails carefully monitoring blood glucose levels and taking corrective steps whenever they are too high or too low. If blood glucose levels could be accurately predicted, patients could take proactive steps to prevent blood glucose excursions from occurring. However, accurate predictions require complex physiological models of blood glucose behavior. Factors such as insulin boluses, carbohydrate intake, and exercise influence blood glucose in ways that are difficult to capture through manually engineered equations. In this paper, we describe a recursive neural network (RNN) approach that uses long short-term memory (LSTM) units to learn a physiological model of blood glucose. When trained on raw data from real patients, the LSTM networks (LSTMs) obtain results that are competitive with a previous state-of-the-art model based on manually engineered physiological equations. The RNN approach can incorporate arbitrary physiological parameters without the need for sophisticated manual engineering, thus holding the promise of further improvements in prediction accuracy.

  1. Effects of medetomidine on serum glucose in cattle calves.

    Science.gov (United States)

    Tariq, Muhammad; Kalhoro, Amir Bukhsh; Sarwar, Mian Saeed; Khan, Hamayun; Ahmad, Shakoor; Hassan, Sayed Mubashir; Zahoor, Arshad

    2016-05-01

    An experimental study was carried out to compare physiological effects (serum glucose level) of medetomidine in Red Sindhi cattle calves at three different doses i.e. 8, 10 and 12µg/kg body weight intravenously. Medetomidine produced a dose dependent significant (P<0.01) increase in serum glucose level with a maximum increase observed at 30 minutes with 8µg/kg, 10μg/kg and 12μg/kg body weight respectively. Start of sedation, degree of sedation and total duration of sedation were all dose dependent and the values obtained were significantly (P<0.01) different from each other. It was observed that the sedation was rapid, deep and longer with the higher doses of medetomidine i.e. 12μg/kg. The results of the present study shows that medetomidine is a very effective and safest drug use as sedative for calves which in lower doses (8μg/kg) can be used as a pre-anesthetic and for restraining of the animal, while higher calculated doses (10μg/kg, 12μg/kg) can be used to execute the minor surgical procedures.

  2. Effect of cinnamon extract on blood glucose level and lipid profile in alloxan induced diabetic rats

    International Nuclear Information System (INIS)

    Mahmood, S.; Khurshid, R.

    2011-01-01

    Background: Cinnamon has been shown to potentiate the hypoglycaemic effect of insulin through up regulation of the glucose uptake in cultured adipocytes of rats. This study tried to find out the effect of Cinnamon alone or in combination with Insulin in diabetic albino rats. Methods: Thirty rats were divided into three groups, A and B. Group A were given cinnamon extract 200 mg/Kg body weight daily orally and group B rats were given cinnamon extract 400 mg/Kg body weight daily. After six weeks blood glucose and lipid profile levels were evaluated in all the groups. Results: Group of rats given 200 mg cinnamon extract showed significant decrease of blood glucose concentration but there was slight or no change in the level of lipid parameters including serum cholesterol, triglyceride and lipoproteins (HDL, LDL-chol). On the other hand group of rats given 400 mg extract of cinnamon showed a better but non significant change in level of lipid related parameter while blood glucose level was significantly decreased. Conclusion: The cinnamon at a dose of 400 mg showed same effects on blood glucose level but better effects on lipid profiles especially of serum cholesterol level of group of rats compared to 200 mg of cinnamon extract. Cinnamon may be recommended as hypoglycaemic herb but not as hypolipidaemic herb. (author)

  3. Association Between Exercise and Blood Glucose Levels In Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Eryna Laili Putri

    2017-02-01

    Full Text Available Diabetes Mellitus (DM is a chronic disease with high prevalence, associated with various debilitating complications and can decreases the quality of life in people with it. It is important for people with DM to doing exercise to control the stability of their blood glucose levels. The purpose of this study was to finding out the association between frequency, duration, and intensity of exercise with average blood glucose levels in people with DM. This was an observational study that used case control design. Data obtained from interview with 20 samples from case group and 20 samples from control group, that had been chosen with systematic random sampling technique. Dependent variable of this study was the average blood glucose levels and independents variables were frequency, duration, intensity, and the kind of exercise. This study used Chi Square test 3 × 2 contingency tables to finding out the association and risk of dependent variable with independent variables,. The results showed that exercise factors that associated to average blood glucose levels were duration of exercise (p = 0.022 and intensity of exercise (p = 0.021. The frequency of exercise does not associated to average blood glucose levels (p = 0.340. Diabetic patients who did not do any exercise have the risk of having uncontrolled blood glucose levels. The conclusion was duration and intensity of exercise related significantly to blood glucose levels. By doing exercise three times a week for 30 minutes or more can decreases the risk of uncontrolled blood glucose levels in people with DM. Keywords: Diabetes mellitus, exercise, average blood glucose levels

  4. Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Arati S. Panchbhai

    2012-07-01

    Full Text Available Objectives: There is alarming rise in number of people with diabetes mellitus over these years. If glucose in saliva is linked to glucose in blood it can be used to detect diabetes mellitus at an early stage. The present study is undertaken with the aim to assess the correlation of salivary glucose level with blood glucose level in people with diabetes mellitus. Material and Methods: For investigations, 2 sets of samples of people with diabetes and the age and sex matched non-diabetic subjects were recruited. The salivary glucose was analyzed in unstimulated whole saliva samples using glucose oxidase method. Pearson’s correlation coefficient test was applied to assess the correlation between salivary glucose level and blood glucose level. Results: The significant (P < 0.05 positive correlation of salivary glucose level and fasting blood glucose level was observed in people with uncontrolled diabetes in both the sets of samples.Conclusions: Although study suggests some potential for saliva as a marker in monitoring of diabetes mellitus, there are many aspects that need clarification before we reach to a conclusion.

  5. Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus

    OpenAIRE

    Arati S. Panchbhai

    2012-01-01

    ABSTRACT Objectives There is alarming rise in number of people with diabetes mellitus over these years. If glucose in saliva is linked to glucose in blood it can be used to detect diabetes mellitus at an early stage. The present study is undertaken with the aim to assess the correlation of salivary glucose level with blood glucose level in people with diabetes mellitus. Material and Methods For investigations, 2 sets of samples of people with diabetes and the age and sex matched non-diabetic ...

  6. Association between blood glucose level derived using the oral glucose tolerance test and glycated hemoglobin level.

    Science.gov (United States)

    Kim, Hyoung Joo; Kim, Young Geon; Park, Jin Soo; Ahn, Young Hwan; Ha, Kyoung Hwa; Kim, Dae Jung

    2016-05-01

    Glycated hemoglobin (HbA1c) is widely used as a marker of glycemic control. Translation of the HbA1c level to an average blood glucose level is useful because the latter figure is easily understood by patients. We studied the association between blood glucose levels revealed by the oral glucose tolerance test (OGTT) and HbA1c levels in a Korean population. A total of 1,000 subjects aged 30 to 64 years from the Cardiovascular and Metabolic Diseases Etiology Research Center cohort were included. Fasting glucose levels, post-load glucose levels at 30, 60, and 120 minutes into the OGTT, and HbA1c levels were measured. Linear regression of HbA1c with mean blood glucose levels derived using the OGTT revealed a significant correlation between these measures (predicted mean glucose [mg/dL] = 49.4 × HbA1c [%] - 149.6; R (2) = 0.54, p Glucose (ADAG) study and Diabetes Control and Complications Trial (DCCT) cohort. Discrepancies between our results and those of the ADAG study and DCCT cohort may be attributable to differences in the test methods used and the extent of insulin secretion. More studies are needed to evaluate the association between HbA1c and self monitoring blood glucose levels.

  7. Opium can differently alter blood glucose, sodium and potassium in male and female rats.

    Science.gov (United States)

    Karam, Gholamreza Asadi; Rashidinejad, Hamid Reza; Aghaee, Mohammad Mehdi; Ahmadi, Jafar; Rahmani, Mohammad Reza; Mahmoodi, Mehdi; Azin, Hosein; Mirzaee, Mohammad Reza; Khaksari, Mohammad

    2008-04-01

    To determine the effects of opium on serum glucose, potassium and sodium in male and female Wistar rat, opium solution (60 mg/kg) injected intraperitoneally and the same volume of distilled water was used as control (7 rats in each group). Blood samples were collected at 0, 30, 60, 120, 240 and 360 minutes after injection from orbit cavity and the values of serum glucose, sodium (Na(+)) and potassium (K(+)) were measured. The data were then analyzed by the repeated measure ANOVA based on sex and case-control group. P opium solution injection, in female rats compared to a control group. However, the male rats had this rise at 30, 60 and 120 minutes after opium solution injection compared to control group. While serum glucose in male rats was significantly higher than females at 30, 60 and 120 minutes, this value was higher in the female rats at 360 minutes. Therefore, serum glucose alterations following opium injection was significantly different in groups and in the sexes at different times. Sodium (Na(+)) rose at 60, 240 and 360 minutes significantly in all rats compared to control group. However, sodium alteration following opium injection was significantly different only between treated and control groups but sex-independent at all times. Potassium (K(+)) increased significantly at 60, 120, 240 and 360 minutes in male rats, compared to a control group. In female rats K(+) significantly raised at 30, 120, 240 and 360 minutes. Therefore, the alteration of K(+) in male and female rats was found time dependent and sex independent. According to our results, opium increased serum glucose in male and female rats differently, and it interferes with metabolic pathways differently on a gender dependent basis. Opium raised serum Na(+) and K(+), thus it interfere with water regulation and blood pressure via different mechanism.

  8. Olfactory stimulation modulates the blood glucose level in rats.

    Science.gov (United States)

    Tsuji, Tadataka; Tanaka, Susumu; Bakhshishayan, Sanam; Kogo, Mikihiko; Yamamoto, Takashi

    2018-01-01

    In both humans and animals, chemosensory stimuli, including odors and tastes, induce a variety of physiologic and mental responses related to energy homeostasis, such as glucose kinetics. The present study examined the importance of olfactory function in glucose kinetics following ingestion behavior in a simplified experimental scenario. We applied a conventional glucose tolerance test to rats with and without olfactory function and analyzed subsequent blood glucose (BG) curves in detail. The loss of olfactory input due to experimental damage to the olfactory mucosa induced a marked decrease in the area under the BG curve. Exposure to grapefruit odor and its main component, limonene, both of which activate the sympathetic nerves, before glucose loading also greatly depressed the BG curve. Pre-loading exposure to lavender odor, a parasympathetic activator, stabilized the BG level. These results suggest that olfactory function is important for proper glucose kinetics after glucose intake and that certain fragrances could be utilized as tools for controlling BG levels.

  9. Association between Blood Levels of Glucose and Urea and the ...

    African Journals Online (AJOL)

    osman

    2017-08-05

    Aug 5, 2017 ... Normal blood glucose and urea levels in dairy cows vary within breeds, ..... prolapse, and postpartum uterine haemorrhage, the effect of metabolic stress, ... and the effect of efficiency of heat detection on the average days to.

  10. Lithium modulates the chronic stress-induced effect on blood glucose level of male rats

    Directory of Open Access Journals (Sweden)

    Popović Nataša

    2010-01-01

    Full Text Available In the present study we examined gross changes in the mass of whole adrenal glands and that of the adrenal cortex, as well as the serum corticosterone and glucose level of mature male Wistar rats subjected to three different treatments: animals subjected to chronic restraint-stress, animals injected with lithium (Li and chronically stressed rats treated with Li. Under all three conditions we observed hypertrophy of whole adrenals, as well as the adrenal cortices. Chronic restraint stress, solely or in combination with Li treatment, significantly elevated the corticosterone level, but did not change the blood glucose level. Animals treated only with Li exhibited an elevated serum corticosterone level and blood glucose level. The aim of our study was to investigate the modulation of the chronic stress-induced effect on the blood glucose level by lithium, as a possible mechanism of avoiding the damage caused by chronic stress. Our results showed that lithium is an agent of choice which may help to reduce stress-elevated corticosterone and replenish exhausted glucose storages in an organism.

  11. Emotionally arousing pictures increase blood glucose levels and enhance recall.

    Science.gov (United States)

    Blake, T M; Varnhagen, C K; Parent, M B

    2001-05-01

    Arousal enhances memory in human participants and this enhancing effect is likely due to the release of peripheral epinephrine. As epinephrine does not readily enter the brain, one way that peripheral epinephrine may enhance memory is by increasing circulating blood glucose levels. The present study investigated the possibility that emotionally arousing color pictures would improve memory and elevate blood glucose levels in human participants. Blood glucose levels were measured before, 15 min, and 30 min after male university students viewed 60 emotionally arousing or relatively neutral pictures. Participants viewed each picture for 6 s and then had 10 s to rate the arousal (emotional intensity) and valence (pleasantness) of each picture. A free-recall memory test was given 30 min after the last picture was viewed. Although the emotionally arousing and neutral picture sets were given comparable valence ratings, participants who viewed the emotionally arousing pictures rated the pictures as being more arousing, recalled more pictures, and had higher blood glucose levels after viewing the pictures than did participants who viewed the neutral pictures. These findings indicate that emotionally arousing pictures increase blood glucose levels and enhance memory, and that this effect is not due to differences in the degree of pleasantness of the stimuli. These findings support the possibility that increases in circulating blood glucose levels in response to emotional arousal may be part of the biological mechanism that allows emotional arousal to enhance memory. Copyright 2001 Academic Press.

  12. Resonator graphene microfluidic antenna (RGMA) for blood glucose detection

    Science.gov (United States)

    Jizat, Noorlindawaty Md.; Mohamad, Su Natasha; Ishak, Muhammad Ikman

    2017-09-01

    Graphene is capable of highly sensitive analyte detection due to its nanoscale nature. Here we show a resonator graphene microfluidic antenna (RGMA) is used to detect the dielectric properties of aqueous glucose solution which represent the glucose level in blood. Simulation verified the high sensitivity of proposed RGMA made with aqueous glucose solutions at different concentrations. The RGMA yielded a sensor sensitivity of 0.1882GHz/mgml-1 as plotted from the slope of the linear fit from the result averages in S11 and S21 parameter, respectively. This results indicate that the proposed resonator antenna achieves high sensitivity and linear to the changes of glucose concentration.

  13. Blood-Brain Glucose Transfer in Alzheimer's disease

    DEFF Research Database (Denmark)

    Gejl, Michael; Brock, Birgitte; Egefjord, Lærke

    2017-01-01

    There are fewer than normal glucose transporters at the blood-brain barrier (BBB) in Alzheimer's disease (AD). When reduced expression of transporters aggravates the symptoms of AD, the transporters become a potential target of therapy. The incretin hormone GLP-1 prevents the decline of cerebral...... metabolic rate for glucose (CMRglc) in AD, and GLP-1 may serve to raise transporter numbers. We hypothesized that the GLP-1 analog liraglutide would prevent the decline of CMRglc in AD by raising blood-brain glucose transfer, depending on the duration of disease. We randomized 38 patients with AD...

  14. Parathyroidectomy Ameliorates Glucose and Blood Pressure Control in a Patient with Primary Hyperparathyroidism, Type 2 Diabetes, and Hypertension

    Directory of Open Access Journals (Sweden)

    Alok Kumar

    2015-01-01

    Full Text Available Effect of parathyroidectomy on glucose control and hypertension is controversial. Here, we report a case of a patient with primary hyperparathyroidism, type 2 diabetes mellitus, and hypertension in whom parathyroidectomy ameliorated both glucose control and blood pressure. Once high serum calcium levels were noticed, ultrasonography of neck confirmed a well-defined oval hypoechoic mass posterior to the right lobe of the thyroid, confirmed by scintiscan. Parathyroidectomy resulted in improvement of blood pressure and blood glucose. We could stop insulin and antihypertensive medications. We conclude that in patients with type 2 diabetes with vague complaints like fatigue, body ache, and refractory hypertension, as a part of the diagnostic workup, clinicians should also check serum calcium levels and parathyroid hormone to rule out hyperparathyroidism. Correction of hyperparathyroidism may result in improvement of hypertension and glucose control.

  15. A data driven nonlinear stochastic model for blood glucose dynamics.

    Science.gov (United States)

    Zhang, Yan; Holt, Tim A; Khovanova, Natalia

    2016-03-01

    The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  16. Effect of Marijuana Smoking on Blood Chemistry and Serum ...

    African Journals Online (AJOL)

    The effect of marijuana smoking on blood chemistry and serum biogenic amines concentrations in humans was investigated. Eighty Marijuana addicts and twenty non- marijuana smokers were used in the study. Blood chemistry and serum biogenic amines concentrations of the marijuana addicts and controls, were ...

  17. Turmeric Supplementation Improves Serum Glucose Indices and Leptin Levels in Patients with Nonalcoholic Fatty Liver Diseases.

    Science.gov (United States)

    Navekar, Roya; Rafraf, Maryam; Ghaffari, Aida; Asghari-Jafarabadi, Mohammad; Khoshbaten, Manouchehr

    2017-01-01

    Insulin and leptin resistance are important risk factors for non-alcoholic fatty liver disease (NAFLD). There is limited evidence regarding the effects of turmeric on NAFLD. The aim of this study was to investigate the effects of turmeric supplementation on glycemic status and serum leptin levels in patients with NAFLD. This double-blind randomized controlled clinical trial was conducted on 46 patients with NAFLD (21males and 25 females) aged 20-60 years old and body mass index (BMI) between 24.9 and 40 kg/m2. The turmeric group (n = 23) was given six turmeric capsules daily for 12 weeks. Each capsule contained 500 mg turmeric powder (6×500 mg). The placebo group (n = 23) was given six placebo capsules daily for the same period. Fasting blood samples, anthropometric measurements, and physical activity levels were collected at the baseline and at the end of the study. Daily dietary intakes also were obtained throughout the study. Data were analyzed by independent t test, paired t test and analysis of covariance. Turmeric consumption decreased serum levels of glucose, insulin, HOMA-IR and leptin (by 1.22, 17.69, 19.48 and 21.33% respectively, p Turmeric supplementation improved glucose indexes and serum leptin levels and may be useful in the control of NAFLD complications.

  18. Correlation of salivary glucose level with blood glucose level in diabetes mellitus.

    Science.gov (United States)

    Gupta, Shreya; Nayak, Meghanand T; Sunitha, J D; Dawar, Geetanshu; Sinha, Nidhi; Rallan, Neelakshi Singh

    2017-01-01

    Saliva is a unique fluid, which is important for normal functioning of the oral cavity. Diabetes mellitus (DM) is a disease of absolute or relative insulin deficiency characterized by insufficient secretion of insulin by pancreatic beta-cells. The diagnosis of diabetes through blood is difficult in children, older adults, debilitated and chronically ill patients, so diagnosis by analysis of saliva can be potentially valuable as collection of saliva is noninvasive, easier and technically insensitive, unlike blood. The aim of the study was to correlate blood glucose level (BGL) and salivary glucose level (SGL) in DM patients. A cross-sectional study was conducted in 120 patients, who were categorized as 40 controlled diabetics, 40 uncontrolled diabetics and 40 healthy, age- and sex-matched individuals constituted the controls. The blood and unstimulated saliva samples were collected from the patients at the different intervals for fasting, random and postprandial levels. These samples were then subjected for analysis of glucose in blood and saliva using glucose oxidase/peroxidase reagent in HITACHI 902 (R) Automatic analyzer, and the results were recorded. The mean SGLs were higher in uncontrolled and controlled diabetic groups than in nondiabetic group. A highly statistically significant correlation was found between fasting saliva glucose and fasting blood glucose in all the groups. With increase in BGL, increase in SGL was observed in patients with diabetes suggesting that SGL can be used for monitoring glycemic level in DM.

  19. Ghrelin administered spinally increases the blood glucose level in mice.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kim, Sung-Su; Kim, Chea-Ha; Kim, Su-Jin; Lim, Su-Min; Jung, Jun-Sub; Suh, Hong-Won

    2014-04-01

    Ghrelin is known as a regulator of the blood glucose homeostasis and food intake. In the present study, the possible roles of ghrelin located in the spinal cord in the regulation of the blood glucose level were investigated in ICR mice. We found that intrathecal (i.t.) injection with ghrelin (from 1 to 10 μg) caused an elevation of the blood glucose level. In addition, i.t. pretreatment with YIL781 (ghrelin receptor antagonist; from 0.1 to 5 μg) markedly attenuated ghrelin-induced hyperglycemic effect. The plasma insulin level was increased by ghrelin. The enhanced plasma insulin level by ghrelin was reduced by i.t. pretreatment with YIL781. However, i.t. pretreatment with glucagon-like peptide-1 (GLP-1; 5 μg) did not affect the ghrelin-induced hyperglycemia. Furthermore, i.t. administration with ghrelin also elevated the blood glucose level, but in an additive manner, in d-glucose-fed model. Our results suggest that the activation of ghrelin receptors located in the spinal cord plays important roles for the elevation of the blood glucose level. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Human blood serum analysis using TRXRF

    International Nuclear Information System (INIS)

    Zarkadas, C.; Karydas, A.G.; Paradellis, T.

    2000-01-01

    Total reflection x-ray fluorescence was applied in the analysis of a pool human blood serum sample, which was collected out of 100 healthy individuals during an ordinary day at a hospital in Athens. Direct measurements of 4 1 quantities were performed in a standard TRXRF module, but with the addition of a Mo filter after the cut-off reflector. In this way the exciting beam was further monochromatized leading to an improved peak to background ratio. The elements S, Cl, K, Ca, Fe, Cu, Zn, Se, Br, Rb were detected, with detection limits in the low ppb region for the elements of interest. The determined trace elements concentrations were found to be in very good agreement with values already reported in literature. For intercomparison a quantity of the same sample was freeze dried and measured in a secondary target assembly, in the form of pellets, giving almost identical results. The trace elements concentrations obtained can be considered as representative values for healthy population of Athens and therefore can be used as a monitor in order to associate the lack or excess of certain trace elements with pathological cases. (author)

  1. Examination of liver and muscle glycogen and blood glucose levels ...

    African Journals Online (AJOL)

    Administrator

    2011-09-05

    Sep 5, 2011 ... changes in fish affect the conversion of liver glycogen into blood ... province, altitude 1248 m and surface area of 86 km2, 20 km in length 4.5 km in width ... alcohol (95% pure) were added, followed by boiling for a further 15 min. ..... water temperature on the blood glucose level of chub (Leuciscus cephalus ...

  2. Fasting blood glucose and haemoglobin concentrations of healthy ...

    African Journals Online (AJOL)

    Menstruation is associated with loss of blood monthly in women of reproductive age. In some women this physiological phenomenon is also associated with some complaints such as menstrual pain, vomiting, and tiredness. We investigated the fasting blood glucose concentration and hemoglobin concentration before and ...

  3. Follow-up of blood glucose distribution characteristics in a health examination population in Chengdu from 2010 to 2016.

    Science.gov (United States)

    Wang, Yuting; Xu, Wangdong; Zhang, Qiongying; Bao, Ting; Yang, Hanwei; Huang, Wenxia; Tang, Huairong

    2018-02-01

    The worldwide prevalence and incidence of diabetes and obesity are increasing in pandemic proportions. Thus, regular health examination is an important way for early detection of diabetes and glucose intolerance. The present study aims to detect the blood glucose distribution characteristics of the participants in the Health Examination Center at West China Hospital, Sichuan University from 2010 to 2016.A prospective cohort included 9168 Chinese participants, aged 18 years or more, who had available information on fasting blood glucose concentrations at the start of the study (2010). Examination surveys were conducted every year from 2010 to 2016. Cases having serum level of fasting blood glucose between 2.2 and 6.1 mmol/L were considered as normality, while serum level of fasting blood glucose level of glucose was gradually reduced both in males and females from 2010 to 2016, by which the percentage of males having normal level of glucose was significantly lower than that in females. Moreover, the mean level of glucose was significantly increased from 2010 to 2016 both in males and females overall, and the mean level of glucose was higher in males compared with that in females every year. Furthermore, we showed that the level of glucose was gradually increased year by year in each age group, and the level of glucose was higher in aged cases compared with the young population.The study population in the current study showed higher levels of glucose with ages increasing, and males indicated higher expression of glucose than that in females. Some preventive action may be adopted early and more attention can be paid to this health-examination population.

  4. Effect of Iranian Honey bee (Apis Mellifera Venom on Blood Glucose and Insulin in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Seyyedeh Mahbubeh Mousavi

    2012-12-01

    Full Text Available Background: Diabetes is an important disease. This disease is a metabolic disorder characterized by hyperglycemia resulting from perturbation in insulin secretion, insulin action or both. Honey bee venom contains a wide range of polypeptide agents. The principle components of bee venom are mellitin and phospholipase A2. These components increase insulin secretion from the β-cells of pancreas. This study was conducted to show the hypoglycemic effect of honey bee venom on alloxan induced diabetic male rats.Methods: Eighteen adult male rats weighting 200±20 g were placed into 3 randomly groups: control, alloxan monohy­drate-induced diabetic rat and treated group that received honey bee venom daily before their nutrition for four months. Forty eight hours after the last injection, blood was collected from their heart, serum was dissented and blood glucose, insulin, triglyceride and total cholesterol were determined.Results: Glucose serum, triglyceride and total cholesterol level in treated group in comparison with diabetic group was significantly decreased (P< 0.01. On the other hand, using bee venom causes increase in insulin serum in com­parison with diabetic group (P< 0.05.Conclusion: Honeybee venom (apitoxin can be used as therapeutic option to lower blood glucose and lipids in dia­betic rats.

  5. Quantitative influence of risk factors on blood glucose level.

    Science.gov (United States)

    Chen, Songjing; Luo, Senlin; Pan, Limin; Zhang, Tiemei; Han, Longfei; Zhao, Haixiu

    2014-01-01

    The aim of this study is to quantitatively analyze the influence of risk factors on the blood glucose level, and to provide theory basis for understanding the characteristics of blood glucose change and confirming the intervention index for type 2 diabetes. The quantitative method is proposed to analyze the influence of risk factors on blood glucose using back propagation (BP) neural network. Ten risk factors are screened first. Then the cohort is divided into nine groups by gender and age. According to the minimum error principle, nine BP models are trained respectively. The quantitative values of the influence of different risk factors on the blood glucose change can be obtained by sensitivity calculation. The experiment results indicate that weight is the leading cause of blood glucose change (0.2449). The second factors are cholesterol, age and triglyceride. The total ratio of these four factors reaches to 77% of the nine screened risk factors. And the sensitivity sequences can provide judgment method for individual intervention. This method can be applied to risk factors quantitative analysis of other diseases and potentially used for clinical practitioners to identify high risk populations for type 2 diabetes as well as other disease.

  6. Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy.

    Science.gov (United States)

    Pandey, Rishikesh; Paidi, Santosh Kumar; Valdez, Tulio A; Zhang, Chi; Spegazzini, Nicolas; Dasari, Ramachandra Rao; Barman, Ishan

    2017-02-21

    The successful development of a noninvasive blood glucose sensor that can operate reliably over sustained periods of time has been a much sought after but elusive goal in diabetes management. Since diabetes has no well-established cure, control of elevated glucose levels is critical for avoiding severe secondary health complications in multiple organs including the retina, kidney and vasculature. While fingerstick testing continues to be the mainstay of blood glucose detection, advances in electrochemical sensing-based minimally invasive approaches have opened the door for alternate methods that would considerably improve the quality of life for people with diabetes. In the quest for better sensing approaches, optical technologies have surfaced as attractive candidates as researchers have sought to exploit the endogenous contrast of glucose, notably its absorption, scattering, and polarization properties. Vibrational spectroscopy, especially spontaneous Raman scattering, has exhibited substantial promise due to its exquisite molecular specificity and minimal interference of water in the spectral profiles acquired from the blood-tissue matrix. Yet, it has hitherto been challenging to leverage the Raman scattering signatures of glucose for prediction in all but the most basic studies and under the least demanding conditions. In this Account, we discuss the newly developed array of methodologies that address the key challenges in measuring blood glucose accurately using Raman spectroscopy and unlock new prospects for translation to sustained noninvasive measurements in people with diabetes. Owing to the weak intensity of spontaneous Raman scattering, recent research has focused on enhancement of signals from the blood constituents by designing novel excitation-collection geometries and tissue modulation methods while our attempts have led to the incorporation of nonimaging optical elements. Additionally, invoking mass transfer modeling into chemometric algorithms has

  7. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  8. Effect of Andrographolide‭ Extract on Blood Glucose and Lipid Profile in Rats with Secondary Iron Overload

    Directory of Open Access Journals (Sweden)

    َArash Mehri Pirayvatlo

    2017-01-01

    Full Text Available Background & objectives: Iron overload is involved in the pathophysiology of many diseases including diabetes. In fact, the excess iron by creating free radicals makes damage to pancreas and leads to insulin resistance and diabetes. Andrographolide extract has hypoglycemic and antioxidant properties. This study has surveyed the effects of andrographolide on blood glucose and lipid profile in rats with secondary iron overload. Methods: In this experimental study, 36 male Wistar rats were randomly divided into 6 groups: the healthy control group, secondary iron overload group, secondary iron overload groups treated with a dose of 3.5 and 7 mg/kg of andrographolide extract, and andrographolide groups treated with a dose of 3.5 and 7 mg/kg of extract. Iron and extract were injected for 6 and 12 days, respectively. Blood samples were taken for measurement of blood glucose and lipid profiles. Data were analyzed using ANOVA test. Results: The pathological results of samples from liver of animals receiving iron showed that the iron was deposited in the liver tissues. Iron injection significantly increased blood glucose levels compared to healthy control group (p<0.05. In the iron overload group, andrographolide extract with a dose of 3.5 mg/kg or 7 mg/kg significantly decreased blood glucose levels (p<0.05. Iron injections did not increase the serum triglyceride and cholesterollevels. Injections of andrographolide extract with a dose of 3.5 mg/kg and 7 mg/kg, significantly decreased the cholesterol levels compared to iron receiving group (p<0.05. Conclusion: Results of this study showed that the andrographolide with different doses may be effective in the treatment of diabetes by reducing serum glucose and cholesterol levels.

  9. Biochemical relationships between bone turnover markers and blood glucose in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Hussein, Rasha M

    2017-11-01

    Patients with type 2 diabetes mellitus develop many complications including osteopenia, which is associated with high fracture risk. Osteocalcin is a non collagenous protein derived from the osteoblasts. Recently, it was found that osteocalcin enhances the pancreatic beta cell proliferation, insulin secretion and protection against type 2 diabetes. Investigation of the association of serum osteocalcin and other bone turnover markers with blood glucose level and diabetes mellitus duration in type 2 diabetic patients. Twenty diagnosed type 2 diabetic patients together with 20 healthy controls were enrolled in this study. Serum osteocalcin, alkaline phosphatase activity and calcium concentrations were measured by commercial ELISA kits. The results showed that type 2 diabetic patients exhibited a significantly lower serum osteocalcin and calcium (p=0.0001 and 0.002 respectively) and a higher alkaline phosphatase (p=0.008) compared to the controls. Multiple linear regression analysis revealed that serum osteocalcin was inversely associated with fasting blood glucose and Diabetes Mellitus duration (β=- 0.018; p=0.007 and β=- 0.085; p=0.014 respectively) in Type 2 diabetic patients. In addition, alkaline phosphatase was positively associated (β=0.828; p=0.015) while serum calcium was negatively associated (β=- 0.046; p=0.048) with Diabetes Mellitus duration. These results refer to the strong association between diabetes and bone turnover markers and call for monitoring of diabetes-associated osteopenia in type 2 diabetic patients. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  10. Radioimmunoassay of serum β2-microglobulin in donor's blood

    International Nuclear Information System (INIS)

    Yin Shihua; Song Shiyun; Li Kelin; Chen Guanglian; Liu Fengmin

    1993-01-01

    Serum β 2 -microglobulin (β 2 -MG) was tested by radioimmunoassay in 149 donors' and 54 healthy volunteers' blood. The results were 203 +- 33.0 nmol/l and 176 +- 26.2 nmol/l, respectively. There was significant difference statistically between them (P 2 -MG content. In order to increase the quality of donated blood and to keep the health of blood donor, it is suggested that the high content of serum β 2 -MG is the indicator of too frequent blood donating. The results also showed that the content of β 2 -MG in donor's blood is not a normal reference value

  11. Twenty-four-hour variations in blood glucose level in Japanese type 2 diabetes patients based on continuous glucose monitoring.

    Science.gov (United States)

    Hajime, Maiko; Okada, Yosuke; Mori, Hiroko; Otsuka, Takashi; Kawaguchi, Mayuko; Miyazaki, Megumi; Kuno, Fumi; Sugai, Kei; Sonoda, Satomi; Tanaka, Kenichi; Kurozumi, Akira; Narisawa, Manabu; Torimoto, Keiichi; Arao, Tadashi; Tanaka, Yoshiya

    2018-01-01

    High fluctuations in blood glucose are associated with various complications. The correlation between glycated hemoglobin (HbA1c) level and fluctuations in blood glucose level has not been studied in Japanese patients with type 2 diabetes. In the present study, blood glucose profile stratified by HbA1c level was evaluated by continuous glucose monitoring (CGM) in Japanese type 2 diabetes patients. Our retrospective study included 294 patients with type 2 diabetes who were divided by HbA1c level into five groups (≥6.0 to level and CGM data was analyzed. The primary end-point was the difference in blood glucose fluctuations among the HbA1c groups. The mean blood glucose level increased significantly with increasing HbA1c (P trend  levels of maximum blood glucose, minimum blood glucose, each preprandial blood glucose, each postprandial maximum blood glucose, range of increase in postprandial glucose from pre-meal to after breakfast, the area under the blood concentration-time curve >180 mg/dL and percentage of the area under the blood concentration-time curve >180 mg/dL were higher with higher HbA1c. Mean glucose level and pre-breakfast blood glucose level were significant and independent determinants of HbA1c. In Japanese patients treated for type 2 diabetes, the mean amplitude of glycemic excursions did not correlate with HbA1c, making it difficult to assess blood glucose fluctuations using HbA1c. Parameters other than HbA1c are required to evaluate fluctuations in blood glucose level in patients receiving treatment for type 2 diabetes. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  12. [A blood glucose slide chart for improving diabetes patient education].

    Science.gov (United States)

    Potteau, Marie-Hélène

    2015-03-01

    A blood glucose slide chart has been developed in order to help patients with type 2 diabetes who do not speak French or who have comprehension difficulties. Combined with pictograms to help patients visualise the action they need to take depending on the recorded glucose level, it constitutes a therapeutic education tool which can be useful on a day-to-day basis both for patients as well as caregivers.

  13. Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring.

    Science.gov (United States)

    Olateju, Tolu; Begley, Joseph; Flanagan, Daniel; Kerr, David

    2012-07-01

    Most manufacturers of blood glucose monitoring equipment do not give advice regarding the use of their meters and strips onboard aircraft, and some airlines have blood glucose testing equipment in the aircraft cabin medical bag. Previous studies using older blood glucose meters (BGMs) have shown conflicting results on the performance of both glucose oxidase (GOX)- and glucose dehydrogenase (GDH)-based meters at high altitude. The aim of our study was to evaluate the performance of four new-generation BGMs at sea level and at a simulated altitude equivalent to that used in the cabin of commercial aircrafts. Blood glucose measurements obtained by two GDH and two GOX BGMs at sea level and simulated altitude of 8000 feet in a hypobaric chamber were compared with measurements obtained using a YSI 2300 blood glucose analyzer as a reference method. Spiked venous blood samples of three different glucose levels were used. The accuracy of each meter was determined by calculating percentage error of each meter compared with the YSI reference and was also assessed against standard International Organization for Standardization (ISO) criteria. Clinical accuracy was evaluated using the consensus error grid method. The percentage (standard deviation) error for GDH meters at sea level and altitude was 13.36% (8.83%; for meter 1) and 12.97% (8.03%; for meter 2) with p = .784, and for GOX meters was 5.88% (7.35%; for meter 3) and 7.38% (6.20%; for meter 4) with p = .187. There was variation in the number of time individual meters met the standard ISO criteria ranging from 72-100%. Results from all four meters at both sea level and simulated altitude fell within zones A and B of the consensus error grid, using YSI as the reference. Overall, at simulated altitude, no differences were observed between the performance of GDH and GOX meters. Overestimation of blood glucose concentration was seen among individual meters evaluated, but none of the results obtained would have resulted in

  14. Repeated Plyometric Exercise Attenuates Blood Glucose in Healthy Adults.

    Science.gov (United States)

    Barillas, Saldiam R; Watkins, Casey M; Wong, Megan A; Dobbs, Ian J; Archer, David C; Munger, Cameron N; Galpin, Andrew J; Coburn, Jared W; Brown, Lee E

    2017-01-01

    Plyometric exercise is popular in commercial exercise programs aiming to maximize energy expenditure for weight loss. However, the effect of plyometric exercise on blood glucose is unknown. The purpose of this study was to investigate the effect of relatively high intensity plyometric exercise on blood glucose. Thirteen subjects (6 females age= 21.8 ± 1.0 yrs.; height= 163.7 ± 7.8 cm; mass= 60.8 ± 6.7 kg and 7 males age= 22.0 ± 2.6 yrs.; height= 182.3 ± 3.6 cm; mass= 87.4 ± 12.5 kg) volunteered to participate. Subjects completed two random conditions on two separate days, consisting of either five sets of 10 maximal effort countermovement squat jumps (SJ) with 50 seconds' rest between sets or quiet sitting (SIT) for the time equated to the SJ duration (~4min). Immediately after each condition, subjects drank 75g of anhydrous glucose (CHO) in 100ml of water. Blood glucose measurements were taken via finger prick pre and immediately post SJ or SIT, and 5, 15, 30, and 60 min post. A 2×6 (condition × time) ANOVA revealed a significant interaction where SJ blood glucose was lower at 15 (114.0 ± 14.6 mg/dl) and 30 (142.1 ± 22.5 mg/dl) min compared to SIT (15min 130.8 ± 14.0 mg/dl and 30min 159.3 ± 21.0 mg/dl). The current plyometric protocol attenuated CHO-induced blood glucose at 15 and 30 min. This may be due to increased physiological stress applied to the muscles, thus increasing muscular glucose uptake.

  15. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  16. Inhaled insulin for controlling blood glucose in patients with diabetes

    Directory of Open Access Journals (Sweden)

    Bernard L Silverman

    2008-01-01

    Full Text Available Bernard L Silverman1, Christopher J Barnes2, Barbara N Campaigne3, Douglas B Muchmore31Alkermes, Inc, Cambridge, MA, USA; 2i3 Statprobe, Ann Arbor, MI; 3Eli Lilly and Company, Indianapolis, IN, USAAbstract: Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients from achieving optimal blood glucose control. The development and utilization of inhaled insulin as a novel insulin delivery system may positively influence patient treatment adherence and optimal glycemic control, potentially leading to a reduction in cardiovascular complications in patients with diabetes.Keywords: diabetes, inhaled insulin, cardiovascular disease, blood glucose

  17. The Eosinophil Count Tends to Be Negatively Associated with Levels of Serum Glucose in Patients with Adrenal Cushing Syndrome

    Directory of Open Access Journals (Sweden)

    Younghak Lee

    2017-09-01

    Full Text Available BackgroundCushing syndrome is characterized by glucose intolerance, cardiovascular disease, and an enhanced systemic inflammatory response caused by chronic exposure to excess cortisol. Eosinopenia is frequently observed in patients with adrenal Cushing syndrome, but the relationship between the eosinophil count in peripheral blood and indicators of glucose level in patients with adrenal Cushing syndrome has not been determined.MethodsA retrospective study was undertaken of the clinical and laboratory findings of 40 patients diagnosed with adrenal Cushing syndrome at Chungnam National University Hospital from January 2006 to December 2016. Clinical characteristics, complete blood cell counts with white blood cell differential, measures of their endocrine function, description of imaging studies, and pathologic findings were obtained from their medical records.ResultsEosinophil composition and count were restored by surgical treatment of all of the patients with adrenal Cushing disease. The eosinophil count was inversely correlated with serum and urine cortisol, glycated hemoglobin, and inflammatory markers in the patients with adrenal Cushing syndrome.ConclusionSmaller eosinophil populations in patients with adrenal Cushing syndrome tend to be correlated with higher levels of blood sugar and glycated hemoglobin. This study suggests that peripheral blood eosinophil composition or count may be associated with serum glucose levels in patients with adrenal Cushing syndrome.

  18. The Eosinophil Count Tends to Be Negatively Associated with Levels of Serum Glucose in Patients with Adrenal Cushing Syndrome.

    Science.gov (United States)

    Lee, Younghak; Yi, Hyon Seung; Kim, Hae Ri; Joung, Kyong Hye; Kang, Yea Eun; Lee, Ju Hee; Kim, Koon Soon; Kim, Hyun Jin; Ku, Bon Jeong; Shong, Minho

    2017-09-01

    Cushing syndrome is characterized by glucose intolerance, cardiovascular disease, and an enhanced systemic inflammatory response caused by chronic exposure to excess cortisol. Eosinopenia is frequently observed in patients with adrenal Cushing syndrome, but the relationship between the eosinophil count in peripheral blood and indicators of glucose level in patients with adrenal Cushing syndrome has not been determined. A retrospective study was undertaken of the clinical and laboratory findings of 40 patients diagnosed with adrenal Cushing syndrome at Chungnam National University Hospital from January 2006 to December 2016. Clinical characteristics, complete blood cell counts with white blood cell differential, measures of their endocrine function, description of imaging studies, and pathologic findings were obtained from their medical records. Eosinophil composition and count were restored by surgical treatment of all of the patients with adrenal Cushing disease. The eosinophil count was inversely correlated with serum and urine cortisol, glycated hemoglobin, and inflammatory markers in the patients with adrenal Cushing syndrome. Smaller eosinophil populations in patients with adrenal Cushing syndrome tend to be correlated with higher levels of blood sugar and glycated hemoglobin. This study suggests that peripheral blood eosinophil composition or count may be associated with serum glucose levels in patients with adrenal Cushing syndrome. Copyright © 2017 Korean Endocrine Society

  19. The optimal blood glucose level for critically ill adult patients.

    Science.gov (United States)

    Lv, Shaoning; Ross, Paul; Tori, Kathleen

    2017-09-01

    Glycaemic control is recognized as one of the important aspects in managing critically ill patients. Both hyperglycaemia and hypoglycaemia independently increase the risk of patient mortality. Hence, the identification of optimal glycaemic control is of paramount importance in the management of critically ill patients. The aim of this literature review is to examine the current status of glycaemic control in critically ill adult patients. This literature review will focus on randomized controlled trials comparing intensive insulin therapy to conventional insulin therapy, with an objective to identify optimal blood glucose level targets for critically ill adult patients. A literature review was conducted to identify large randomized controlled trials for the optimal targeted blood glucose level for critically ill adult patients published since 2000. A total of eight studies fulfilled the selection criteria of this review. With current human and technology resources, the results of the studies support commencing glycaemic control once the blood glucose level of critically ill patients reaches 10 mmol/L and maintaining this level between 8 mmol/L and 10 mmol/L. This literature review provides a recommendation for targeting the optimal blood glucose level for critically ill patients within moderate blood glucose level target range (8-10 mmol/L). The need for uniformed glucometrics for unbiased reporting and further research for optimal blood glucose target is required, especially in light of new technological advancements in closed-loop insulin delivery and monitoring devices. This literature review has revealed a need to call for consensus in the measurement and reporting of glycaemic control using standardized glucometrics. © 2017 British Association of Critical Care Nurses.

  20. Relationship between Serum Iron Profile and Blood Groups among the Voluntary Blood Donors of Bangladesh.

    Science.gov (United States)

    Hoque, M M; Adnan, S D; Karim, S; Al-Mamun, M A; Faruki, M A; Islam, K; Nandy, S

    2016-04-01

    Blood donation results in a substantial iron loss and subsequent mobilization from body stores. Chronic iron deficiency is a well-recognized complication of regular blood donation. The present study conducted to compare the level of serum ferritin, serum iron, total iron binding capacity (TIBC) and percentage transferrin saturation in different ABO and Rhesus type blood groups among the voluntary blood donors of Bangladesh. The present prospective study included 100 healthy voluntary donors attending at Department of Blood Transfusion, Dhaka Medical College, Dhaka between the periods of July 2013 to Jun 2014. From each donor 10mL venous blood sample was taken and divided into heparinized and non-heparinized tubes for determination of hemoglobin (Hb), hematocrit (Hct), serum iron (SI), total iron binding capacity (TIBC) and serum ferritin by standard laboratory methods. Percentage of transferrin saturation (TS) calculated from serum iron and TIBC. Data were analyzed with SPSS (version 16) software and comparisons between groups were made using student's t-test and one way ANOVA. In the present study mean±SD of age of the respondents was 27.2±6.5 years with a range of 18 to 49 years and 81.0% were male and 19.0% were female. Among the donors 18.0% had blood group A, 35.0% had blood group B, 14.0% had blood group AB and 33.0% had blood group O. Among the donors 91.0% had rhesus positive and 9.0% had rhesus negative. Donors with blood group O had lowest haemoglobin, serum iron and transferring saturation levels. Donors with blood group A had highest TIBC level. Donors with blood group B had lowest serum ferritin level. An independent samples 't' test showed statistically significant difference in serum ferritin and percentage transferrin saturation between blood group AB and blood group O and in percentage transferrin saturation between blood group B and blood group O. One way ANOVA showed that there is no significant difference in haemoglobin, serum iron, serum

  1. Robust blood-glucose control using Mathematica.

    Science.gov (United States)

    Kovács, Levente; Paláncz, Béla; Benyó, Balázs; Török, László; Benyó, Zoltán

    2006-01-01

    A robust control design on frequency domain using Mathematica is presented for regularization of glucose level in type I diabetes persons under intensive care. The method originally proposed under Mathematica by Helton and Merino, --now with an improved disturbance rejection constraint inequality--is employed, using a three-state minimal patient model. The robustness of the resulted high-order linear controller is demonstrated by nonlinear closed loop simulation in state-space, in case of standard meal disturbances and is compared with H infinity design implemented with the mu-toolbox of Matlab. The controller designed with model parameters represented the most favorable plant dynamics from the point of view of control purposes, can operate properly even in case of parameter values of the worst-case scenario.

  2. Effects of MDMA on blood glucose levels and brain glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Soto-Montenegro, M.L.; Vaquero, J.J.; Garcia-Barreno, P.; Desco, M. [Hospital General Universitario Gregorio Maranon, Laboratorio de Imagen, Medicina Experimental, Madrid (Spain); Arango, C. [Hospital General Gregorio Maranon, Departamento de Psiquiatria, Madrid (Spain); Ricaurte, G. [Johns Hopkins University School of Medicine, Department of Neurology, Baltimore, MD (United States)

    2007-06-15

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  3. Effects of MDMA on blood glucose levels and brain glucose metabolism

    International Nuclear Information System (INIS)

    Soto-Montenegro, M.L.; Vaquero, J.J.; Garcia-Barreno, P.; Desco, M.; Arango, C.; Ricaurte, G.

    2007-01-01

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  4. Screening of Glucose-6-Phosphate Dehydrogenase Deficiency in Cord Blood

    Directory of Open Access Journals (Sweden)

    Can Acipayam

    2014-02-01

    Aim: Glucose-6-phosphate dehydrogenase deficiency is an important factor in etiology of pathologic neonatal jaundice. The aim of this study was to indicate the significance of screening glucose-6-phosphate dehydrogenase deficiency in the cord blood of neonates and the frequency of this deficiency in the etiology of neonatal hyperbilirubinemia. Material and Method: The study was performed consecutive 1015 neonates were included. Five hundred fifty six (54.8% of them were male and 459 (45.2% were female. The following parameters were recorded: Gender, birth weight, birth height, head circumference and gestational age. The glucose-6-phosphate dehydrogenase level of neonates were measured with quantitative method in cord blood. Also, hemoglobine, hematocrite, red blood cell count and blood group were measured. The following parameters were recorded in cases with jaundice: exchange transfusion, phototherapy, physiologic and pathologic jaundice, peak bilirubin day, maximum bilirubin level, total bilirubin level at the first day of jaundice, beginning time of jaundice. Results: Enzyme deficiency was detected in 133 (13.1% of neonates and 76 (57% of them were male, 57 (43% were female. Significant difference was detected in low glucose-6-phosphate dehydrogenase enzyme level with jaundice group for total bilirubin level at the first day of jaundice, maximum total bilirubin level and pathologic jaundice (p<0.05. Discussion: The ratio of glucose-6-phosphate dehydrogenase deficiency was found in Edirne in this study and this ratio was higher than other studies conducted in our country. For this reason, glucose-6-phosphate dehydrogenase enzyme level in cord blood of neonates should be measured routinely and high risk neonates should be followed up for hyperbilirubinemia and parents should be informed in our region.

  5. Correlation of the association of serum lactate, random blood sugar ...

    African Journals Online (AJOL)

    Correlation of the association of serum lactate, random blood sugar, and revised trauma score as predictors of outcome in hemodynamically unstable abdominal emergencies. E Allwell‑Brown, OO Afuwape, O Ayandipo, T Alonge ...

  6. Responses of Blood Glucose, Insulin, Glucagon, and Fatty Acids to Intraruminal Infusion of Propionate in Hanwoo

    Directory of Open Access Journals (Sweden)

    Y. K. Oh

    2015-02-01

    Full Text Available This study was carried out to investigate the effects of intraruminal infusion of propionate on ruminal fermentation characteristics and blood hormones and metabolites in Hanwoo (Korean cattle steers. Four Hanwoo steers (average body wt. 270 kg, 13 month of age equipped with rumen cannula were infused into rumens with 0.0 M (Water, C, 0.5 M (37 g/L, T1, 1.0 M (74 g/L, T2 and 1.5 M (111 g/L, T3 of propionate for 1 hour per day and allotted by 4×4 Latin square design. On the 5th day of infusion, samples of rumen and blood were collected at 0, 60, 120, 180, and 300 min after intraruminal infusion of propionate. The concentrations of serum glucose and plasma glucagon were not affected (p>0.05 by intraruminal infusion of propionate. The serum insulin concentration at 60 min after infusion was significantly (p<0.05 higher in T3 than in C, while the concentration of non-esterified fatty acid (NEFA at 60 and 180 min after infusion was significantly (p<0.05 lower in the propionate treatments than in C. Hence, intraruminal infusion of propionate stimulates the secretion of insulin, and decreases serum NEFA concentration rather than the change of serum glucose concentration.

  7. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  8. Blood plasma glucose regulation in Wahlberg's epauletted fruit bat ...

    African Journals Online (AJOL)

    Frugivores feed on fruits and nectars that contain different types of sugars in different proportions, which provide these animals with energy. Wahlberg's epauletted fruit bat (Epomophorus wahlbergi) has a high glucose intake irrespective of sugar concentration of nectar. It is not known how these bats regulate their blood ...

  9. Changes in blood glucose and plasma lipids during gestation in ...

    African Journals Online (AJOL)

    Ten female Chinchilla rabbits with mean weight (1.9±0.1kg) were randomly assigned into two groups comprising of five each, to evaluate the changes in blood glucose and lipid profile during pregnancy. Control Group A was mated without prior synchronization, while rabbits in group B were synchronized with 0.15mg/kg ...

  10. Effect of Cola acuminate on Blood Glucose and Glycosylated ...

    African Journals Online (AJOL)

    The levels of blood glucose and glycosylated haemoglobin (GHB) were studied in 42 Wistar rats divided into three groups; controls, group A and group B. Control rats consumed only feeds, group A consumed 0.04g of Cola acuminate, while group B consumed 0.08g of Cola acuminate mixed with their feeds daily for six ...

  11. Effects of Watermelon ( Citrullus lanatus ) Seed on Blood Glucose ...

    African Journals Online (AJOL)

    Given the prevalence of diabetes worldwide, with its associated complications, this study is aimed at investigating the effect of citrullus lanatus seed extract on blood glucose concentration and electrolyte parameters. Citrullus lanatus is an antioxidant and has been shown to reduce oxidative stress (Khaki et al., 2013). Effects ...

  12. Impact of Diet Composition on Blood Glucose Regulation.

    Science.gov (United States)

    Russell, Wendy R; Baka, Athanasia; Björck, Inger; Delzenne, Nathalie; Gao, Dan; Griffiths, Helen R; Hadjilucas, Ellie; Juvonen, Kristiina; Lahtinen, Sampo; Lansink, Mirian; Loon, Luc Van; Mykkänen, Hannu; Östman, Elin; Riccardi, Gabriele; Vinoy, Sophie; Weickert, Martin O

    2016-01-01

    Nutritional management of blood glucose levels is a strategic target in the prevention and management of type 2 diabetes mellitus (T2DM). To implement such an approach, it is essential to understand the effect of food on glycemic regulation and on the underlying metabolic derangements. This comprehensive review summarizes the results from human dietary interventions exploring the impact of dietary components on blood glucose levels. Included are the major macronutrients; carbohydrate, protein and fat, micronutrient vitamins and minerals, nonnutrient phytochemicals and additional foods including low-calorie sweeteners, vinegar, and alcohol. Based on the evidence presented in this review, it is clear that dietary components have significant and clinically relevant effects on blood glucose modulation. An integrated approach that includes reducing excess body weight, increased physical activity along with a dietary regime to regulate blood glucose levels will not only be advantages in T2DM management, but will benefit the health of the population and limit the increasing worldwide incidence of T2DM.

  13. Blood glucose response of normoglycemic adults fed breakfast ...

    African Journals Online (AJOL)

    Gift

    Effect of high fibre leguminous products in breakfast porridges, made from Afzelia Africana (AA), ... Fasting and postprandial blood glucose levels were taken at 30 min interval for 2 .... ml to CSS and each was cooked (stirred continuously) for 10 min to ..... prevalence of diabetes, overweight/obesity and physical inactivity in.

  14. Data-driven analysis of blood glucose management effectiveness

    NARCIS (Netherlands)

    Nannings, B.; Abu-Hanna, A.; Bosman, R. J.

    2005-01-01

    The blood-glucose-level (BGL) of Intensive Care (IC) patients requires close monitoring and control. In this paper we describe a general data-driven analytical method for studying the effectiveness of BGL management. The method is based on developing and studying a clinical outcome reflecting the

  15. Participation in blood glucose test, knowledge and prevalence of ...

    African Journals Online (AJOL)

    Background: Diabetes mellitus causes great health complications which include cardiovascular diseases and nerve damage. Aim: To ascertain the participation in blood glucose test, knowledge of diabetes mellitus (DM) and prevalence of hyperglycemia among traders at New market, Enugu State. Methods: The study is a ...

  16. Blood glucose lowering effect of aqueous extract of Graptophyllum ...

    African Journals Online (AJOL)

    ... 10 mg/kg body weight metformin, a well known hypoglycemic drug, while group 5 served as control and received the vehicle of administration (distilled water). The fasting blood glucose level (FBGL) of the rats was checked before commencement of treatment and weekly during the drug administration period using Roche ...

  17. Predictors of Daily Blood Glucose Monitoring in Appalachian Ohio

    Science.gov (United States)

    Raffle, Holly; Ware, Lezlee J.; Ruhil, Anirudh V. S.; Hamel-Lambert, Jane; Denham, Sharon A.

    2012-01-01

    Objective: To determine factors contributing to successful diabetes self-management in Appalachia, as evidenced by daily blood glucose monitoring. Methods: A telephone survey (N = 3841) was conducted to assess health status and health care access. The current investigation is limited to the subset of this sample who report having diabetes (N =…

  18. Variations of blood glucose in cancer patients during chemotherapy ...

    African Journals Online (AJOL)

    Purpose: The aim of this study was to analyze the blood glucose (BG) variations in cancer patients during chemotherapy according to tumor types and chemotherapeutic regimens. Materials and Methods: Patients were examined from the Department of Medical Oncology of Cancer Hospital and Institute, Chinese Academy ...

  19. Mesenteric blood flow, glucose absorption and blood pressure responses to small intestinal glucose in critically ill patients older than 65 years.

    Science.gov (United States)

    Sim, Jennifer A; Horowitz, M; Summers, M J; Trahair, L G; Goud, R S; Zaknic, A V; Hausken, T; Fraser, J D; Chapman, M J; Jones, K L; Deane, A M

    2013-02-01

    To compare nutrient-stimulated changes in superior mesenteric artery (SMA) blood flow, glucose absorption and glycaemia in individuals older than 65 years with, and without, critical illness. Following a 1-h 'observation' period (t (0)-t (60)), 0.9 % saline and glucose (1 kcal/ml) were infused directly into the small intestine at 2 ml/min between t (60)-t (120), and t (120)-t (180), respectively. SMA blood flow was measured using Doppler ultrasonography at t (60) (fasting), t (90) and t (150) and is presented as raw values and nutrient-stimulated increment from baseline (Δ). Glucose absorption was evaluated using serum 3-O-methylglucose (3-OMG) concentrations during, and for 1 h after, the glucose infusion (i.e. t (120)-t (180) and t (120)-t (240)). Mean arterial pressure was recorded between t (60)-t (240). Data are presented as median (25th, 75th percentile). Eleven mechanically ventilated critically ill patients [age 75 (69, 79) years] and nine healthy volunteers [70 (68, 77) years] were studied. The magnitude of the nutrient-stimulated increase in SMA flow was markedly less in the critically ill when compared with healthy subjects [Δt (150): patients 115 (-138, 367) versus health 836 (618, 1,054) ml/min; P = 0.001]. In patients, glucose absorption was reduced during, and for 1 h after, the glucose infusion when compared with health [AUC(120-180): 4.571 (2.591, 6.551) versus 11.307 (8.447, 14.167) mmol/l min; P AUC(120-240): 26.5 (17.7, 35.3) versus 40.6 (31.7, 49.4) mmol/l min; P = 0.031]. A close relationship between the nutrient-stimulated increment in SMA flow and glucose absorption was evident (3-OMG AUC(120-180) and ∆SMA flow at t (150): r (2) = 0.29; P 65 years, stimulation of SMA flow by small intestinal glucose infusion may be attenuated, which could account for the reduction in glucose absorption.

  20. Discrete Blood Glucose Control in Diabetic Göttingen Minipigs

    Directory of Open Access Journals (Sweden)

    Berno J.E. Misgeld

    2016-07-01

    Full Text Available Despite continuous research effort, patients with type 1 diabetes mellitus (T1D experience difficulties in daily adjustments of their blood glucose concentrations. New technological developments in the form of implanted intravenous infusion pumps and continuous blood glucose sensors might alleviate obstacles for the automatic adjustment of blood glucose concentration. These obstacles consist, for example, of large time-delays and insulin storage effects for the subcutaneous/interstitial route. Towards the goal of an artificial pancreas, we present a novel feedback controller approach that combines classical loop-shaping techniques with gain-scheduling and modern H ∞ -robust control approaches. A disturbance rejection design is proposed in discrete frequency domain based on the detailed model of the diabetic Göttingen minipig. The model is trimmed and linearised over a large operating range of blood glucose concentrations and insulin sensitivity values. Controller parameters are determined for each of these operating points. A discrete H ∞ loop-shaping compensator is designed to increase robustness of the artificial pancreas against general coprime factor uncertainty. The gain scheduled controller uses subcutaneous insulin injection as a control input and determines the controller input error from intravenous blood glucose concentration measurements, where parameter scheduling is achieved by an estimator of the insulin sensitivity parameter. Thus, only one controller stabilises a family of animal models. The controller is validated in silico with a total number of five Göttingen Minipig models, which were previously obtained by experimental identification procedures. Its performance is compared with an experimentally tested switching PI-controller.

  1. Elevated Hemoglobin A1C Levels Correlate with Blood Glucose Elevation in Diabetic Patients following Local Corticosteroid Injection in the Hand: A Prospective Study.

    Science.gov (United States)

    Kim, Nayoung; Schroeder, Jake; Hoffler, C Edward; Matzon, Jonas L; Lutsky, Kevin F; Beredjiklian, Pedro K

    2015-10-01

    Diabetic patients develop hand conditions that are managed with local corticosteroid injections. Injections can result in a transient elevation in serum glucose in diabetic patients. Hemoglobin A1c is the accepted measure of long-term plasma glucose control in diabetics (levels ≥7 percent reflect poor blood glucose control). The purpose of this study was to assess the relationship between hemoglobin A1c levels and increased blood glucose levels after corticosteroid injections. Twenty-five diabetic patients were evaluated prospectively. One milliliter containing 10 mg of triamcinolone acetonide was used. The most recent hemoglobin A1c level and normal average blood glucose levels were obtained. Glucose levels were obtained from patient recall of their daily blood glucose self- monitoring on the day of the injection. Postinjection blood glucose levels were recorded until levels returned to preinjection baseline. Twenty patients (80 percent) had elevation of their blood glucose level from baseline. No patient had elevated blood glucose levels after 5 days. Patients with hemoglobin A1c levels greater than or equal to 7 percent had a higher blood glucose elevation and maintained this for longer than those who had a lower hemoglobin A1c level. Patients in the higher hemoglobin A1c group also had a higher number of hyperglycemic events. There was a strong or moderate correlation between hemoglobin A1c and elevated blood glucose levels during days 1 to 4. Patients with hemoglobin A1c levels greater than or equal to 7 percent have elevations in blood glucose that are higher and last longer than patients with lower levels. Hemoglobin A1c levels can be used to roughly predict the degree of blood glucose elevation after corticosteroid injections into the hands of diabetic patients.

  2. Effect of emulin on blood glucose in type 2 diabetics.

    Science.gov (United States)

    Ahrens, Milton Joseph; Thompson, Daryl L

    2013-03-01

    Emulin™ is a patented blend of chlorogenic acid, myricetin, and quercetin that has shown efficacy in reducing midday and post-oral glucose tolerance test (OGTT) area under the curve (AUC) glucose in streptozotocin-treated rats. The purpose of this study was to determine if similar effects would be evident in type 2 diabetic humans. Forty human subjects with confirmed type 2 diabetes (10 each in 4 groups: placebo/no medication, Emulin/no medication, placebo/metformin and Emulin/metformin) were evaluated. At the end of 1 week, fasting blood glucose, 2 h postprandial, actual peak glucose, and AUC (post-50 g OGTT) were determined. The placebo-only group had a large (5%-13%) increase in all parameters. The Emulin group and those on metformin performed similarly with reductions between 1% and 5%, with Emulin slightly outperforming the medication-alone group. The most significant reduction occurred in the Emulin/metformin group, with decreases in the parameters by up to 20%. These results suggest that Emulin, if consumed regularly, could not only have the acute effect of lowering the glycemic impact of foods, but chronically lower background blood glucose levels of type 2 diabetics.

  3. Blood gas and serum biochemical RIs for healthy newborn Murrah buffaloes (Bubalus bubalis).

    Science.gov (United States)

    Santana, André M; Silva, Daniela G; Clemente, Virna; Pizauro, Lucas J L; Bernardes, Priscila A; Santana, Clarissa H; Eckersall, Peter D; Fagliari, José J

    2018-03-01

    There is a lack of published work on RIs for newborn buffaloes. Establishing blood gas and serum biochemical RIs for newborn buffaloes is important for monitoring health. This study establishes blood gas and serum biochemical RIs of newborn buffaloes. Twenty-eight newborn buffaloes, 10-30 days old, were selected. Thirty blood biochemical variables were analyzed. The Anderson-Darling test was used to assess the normality of the distribution. The Dixon test and the Tukey test were used to identify outliers. The RI and 90% CI were determined using standard and robust methods and the Box-Cox transformation. A total of 30 RIs for healthy buffalo calves have been reported in this study. RIs for blood gas variables were reported for pH, partial pressure of oxygen (pO 2 ), partial pressure of carbon dioxide (pCO 2 ), saturation of O 2 (SO 2 ), bicarbonate (cHCO 3 - ), base excess (BE), total carbon dioxide (ctCO 2 ), and anion gap (AG). RIs for serum biochemical variables were reported for glucose (GLU), direct bilirubin (DB), total bilirubin (TB), AST, ALP, GGT, CK, LDH, creatinine (CREA), urea, cholesterol (CHOL), triglycerides (TG), Ca, P, Mg, Na, K, iCa, Cl, iron, total protein (TP), and albumin (ALB). This is the first reported study covering complete serum chemistry and blood gas RIs for healthy 1-month-old Murrah buffaloes. © 2018 American Society for Veterinary Clinical Pathology.

  4. Fluorescent blood glucose monitor by hemin-functionalized graphene quantum dots based sensing system

    Energy Technology Data Exchange (ETDEWEB)

    He, Yuezhen; Wang, Xiaoxun; Sun, Jian; Jiao, Shoufeng; Chen, Hongqi; Gao, Feng; Wang, Lun, E-mail: wanglun@mail.ahnu.edu.cn

    2014-01-31

    Graphical abstract: -- Highlights: •Hemin is assembled onto the surfaces of graphene quantum dots (GQDs). •With the aid of hemin, H{sub 2}O{sub 2} could quench the FL signal of GQDs obviously. •Based on this effect, a fluorescent platform is proposed for the sensing of glucose. •The proposed method provides a new pathway to explore practical application of GQDs. -- Abstract: In the present work, a highly sensitive and specific fluorescent biosensor for blood glucose monitoring is developed based on hemin-functionalized graphene quantum dots (GQDs) and glucose oxidase (GOx) system. The GQDs which are simply prepared by pyrolyzing citric acid exhibit strong fluorescence and good water-solubility. Due to the noncovalent assembly between hemin and GQDs, the addition of hemin can make hydrogen peroxide (H{sub 2}O{sub 2}) to destroy the passivated surface of GQDs, leading to significant fluorescence quenching of GQDs. Based on this effect, a novel fluorescent platform is proposed for the sensing of glucose. Under the optimized conditions, the linear range of glucose is from 9 to 300 μM, and the limit of detection is 0.1 μM. As unique properties of GQDs, the proposed biosensor is green, simple, cost-efficient, and it is successfully applied to the determination of glucose in human serum. In addition, the proposed method provides a new pathway to further design the biosensors based on the assembly of GQDs with hemin for detection of biomolecules.

  5. Noninvasive biosensor and wireless interrogating system for glucose in blood

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.

    2003-07-01

    Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.

  6. Acute effect of glucose on cerebral blood flow, blood oxygenation, and oxidative metabolism.

    Science.gov (United States)

    Xu, Feng; Liu, Peiying; Pascual, Juan M; Xiao, Guanghua; Huang, Hao; Lu, Hanzhang

    2015-02-01

    While it is known that specific nuclei of the brain, for example hypothalamus, contain glucose-sensing neurons thus their activity is affected by blood glucose level, the effect of glucose modulation on whole-brain metabolism is not completely understood. Several recent reports have elucidated the long-term impact of caloric restriction on the brain, showing that animals under caloric restriction had enhanced rate of tricarboxylic acid cycle (TCA) cycle flux accompanied by extended life span. However, acute effect of postprandial blood glucose increase has not been addressed in detail, partly due to a scarcity and complexity of measurement techniques. In this study, using a recently developed noninvasive MR technique, we measured dynamic changes in global cerebral metabolic rate of O2 (CMRO2 ) following a 50 g glucose ingestion (N = 10). A time dependent decrease in CMRO2 was observed, which was accompanied by a reduction in oxygen extraction fraction (OEF) with unaltered cerebral blood flow (CBF). At 40 min post-ingestion, the amount of CMRO2 reduction was 7.8 ± 1.6%. A control study without glucose ingestion was performed (N = 10), which revealed no changes in CMRO2 , CBF, or OEF, suggesting that the observations in the glucose study was not due to subject drowsiness or fatigue after staying inside the scanner. These findings suggest that ingestion of glucose may alter the rate of cerebral metabolism of oxygen in an acute setting. © 2014 Wiley Periodicals, Inc.

  7. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  8. Can gingival crevicular blood be relied upon for assessment of blood glucose level?

    Science.gov (United States)

    Dwivedi, Shivani; Verma, Sharmila J; Shah, Monali; Jain, Kapil

    2014-11-01

    Diabetes mellitus (DM) is undiagnosed in approximately half of the patients actually suffering from the disease. In addition, the prevalence of DM is more than twice as high as in patients with periodontitis when compared to periodontally healthy subjects. Thus, a high number of patients with periodontitis may have undiagnosed DM. The purpose of the present study was to evaluate whether blood oozing from a gingival crevice during routine periodontal examination can be used for determining glucose levels. Observational cross-sectional studies were carried out in 75 patients (43 males and 32 females) with chronic periodontitis who were divided into two groups: Group I and Group II, respectively. Blood oozing from the gingival crevices of anterior teeth following periodontal probing was collected with the stick of glucose self-monitoring device, and the blood glucose levels were measured. At the same time, finger-prick blood was taken for glucometric analysis and subsequent readings were recorded. The patient's blood glucose values ranged from 74 to 256 mg/dl. The comparison between gingival crevicular blood and finger-prick blood showed a very strong correlation, with a t value of 3.97 (at P value = 0.001). The data from this study has shown that GCB collected during diagnostic periodontal examination can be an excellent source of blood for glucometric analysis.

  9. High Blood Glucose: What It Means and How To Treat It

    Science.gov (United States)

    ... People who do not have diabetes typically have fasting plasma blood glucose levels that run under 100 ... blood glucose? Be sure to drink plenty of water. It is recommended to drink a minimum of ...

  10. Facilitated transport of glucose from blood to brain in man and the effect of moderate hypoglycaemia on cerebral glucose utilization

    International Nuclear Information System (INIS)

    Blomqvist, G.; Widen, L.; Hellstrand, E.; Gutniak, M.; Grill, V.

    1991-01-01

    The effect of steady-state moderate hypoglycaemia on human brain homeostasis has been studied with positron emission tomography using D-glucose 11 C(ul) as tracer. To rule out any effects of insulin, the plasma insulin concentration was maintained at the same level under normo- and hypoglycaemic conditions. Reduction of blood glucose by 55% increased the glucose clearance through the blood-brain barrier by 50% and reduced brain glucose consumption by 40%. Blood flow was not affected. The results are consistent with facilitated transport of glucose from blood to brain in humans. The maximal transport rate of glucose from blood to brain was found to be 62±19 (mean±SEM) μmol hg -1 min -1 , and the half-saturation constant was found to be 4.1±3.2 mM. (orig.)

  11. Diurnal Variations in Serum Glucose, Insulin and C-Peptide of Normal Korean Adults

    International Nuclear Information System (INIS)

    Choi, Du Hyok; Chung, June Key; Lee, Hong Kyu; Koh, Chang Soon; Hong, Kee Suk

    1983-01-01

    It is already well known that many factors are involved in maintaining normal blood glucose level. The amount and components of meal are also thought to be some of the factors which affect the blood glucose and insulin levels. It is reported that as for Koreans sugar takes up over 75% out of 2,098 kcal, the average daily calorie intake per adult. It implies that Koreans take a high-sugar diet compared with Westerners who take 40-50% of sugar out of their total average daily calorie. For the purpose of studying diurnal variations in serum glucose, insulin and C-peptide of normal Koreans adults based on ordinary Korean diet, we selected 13 normal Korean male adults and divided them into two groups, Group I (7 persons) and Group II (6 persons). We put Group I on 3,100 kcal and 75% sugar diet, and Group II on 2,100 kcal and 69% sugar diet per day for over 4 days. Serum glucose, insulin and C-peptide were checked every 30 minutes or every hour throughout 2 hour. Results are as follows: 1. As for serum glucose level, in the preprandial fasting state in the morning, mean±S.D. of Group I was 91.1±3.2 mg%, while that of Group II is 82.5±4.4 mg%. Both groups showed peaks of increased glucose level t postprandial 1 hour after each meal. The peak returned to the level shown during the fasting state at postprandial 1 hour after breakfast while the relatively high glucose levels were maintained respectively even for 2 or 3 hours after lunch and dinner. 2. As for serum insults level, Group I showed mean±S.D. of 14.7±3.0 μU/ml while Group II shows that of 7.0±2.6 μU/ml in the fasting state. Group I particularly showed the largest peak from preprandial a half or one and half an hour to postprandial one hour of lunch, and made relatively small peaks (47.7±10.8 μU/ml) at postprandial 1 hour after breakfast and dinner. No such large peak was marked in Group II, though it showed relatively similar patterns of peak after each meal. 3. As for C-peptide, in the fasting state

  12. Diurnal Variations in Serum Glucose, Insulin and C-Peptide of Normal Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Du Hyok; Chung, June Key; Lee, Hong Kyu; Koh, Chang Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Hong, Kee Suk [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1983-03-15

    It is already well known that many factors are involved in maintaining normal blood glucose level. The amount and components of meal are also thought to be some of the factors which affect the blood glucose and insulin levels. It is reported that as for Koreans sugar takes up over 75% out of 2,098 kcal, the average daily calorie intake per adult. It implies that Koreans take a high-sugar diet compared with Westerners who take 40-50% of sugar out of their total average daily calorie. For the purpose of studying diurnal variations in serum glucose, insulin and C-peptide of normal Koreans adults based on ordinary Korean diet, we selected 13 normal Korean male adults and divided them into two groups, Group I (7 persons) and Group II (6 persons). We put Group I on 3,100 kcal and 75% sugar diet, and Group II on 2,100 kcal and 69% sugar diet per day for over 4 days. Serum glucose, insulin and C-peptide were checked every 30 minutes or every hour throughout 2 hour. Results are as follows: 1. As for serum glucose level, in the preprandial fasting state in the morning, mean+-S.D. of Group I was 91.1+-3.2 mg%, while that of Group II is 82.5+-4.4 mg%. Both groups showed peaks of increased glucose level t postprandial 1 hour after each meal. The peak returned to the level shown during the fasting state at postprandial 1 hour after breakfast while the relatively high glucose levels were maintained respectively even for 2 or 3 hours after lunch and dinner. 2. As for serum insults level, Group I showed mean+-S.D. of 14.7+-3.0 muU/ml while Group II shows that of 7.0+-2.6 muU/ml in the fasting state. Group I particularly showed the largest peak from preprandial a half or one and half an hour to postprandial one hour of lunch, and made relatively small peaks (47.7+-10.8 muU/ml) at postprandial 1 hour after breakfast and dinner. No such large peak was marked in Group II, though it showed relatively similar patterns of peak after each meal. 3. As for C-peptide, in the fasting state

  13. Effects of glucose oxidase on the growth performance, serum ...

    African Journals Online (AJOL)

    Martina

    2016-02-06

    Feb 6, 2016 ... The experiment was conducted to investigate the effects of diets supplemented with ... Keywords: Glucose oxidase, intestinal health, performance, swine ..... This work was supported by the National High-Tech Research and ...

  14. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  15. The effect of serum from obese and normal weight men on glucose metabolism in leucocytes

    International Nuclear Information System (INIS)

    Myking, O.; Kjoesen, B.; Bassoee, H.H.

    1980-01-01

    The influence of pooled serum from either obese or normal weight males on glucose metabolism in human leucocytes has been studied. Leucocytes from normal weight males were incubated with 10-90% pooled serum and either [U- 14 C], or [1- 14 C]glucose. Compared to serum from the normal weight males, serum from the obese group had a more stimulating effect on the 14 CO 2 and [ 14 C]lactate production from [U- 14 C]glucose and on the 14 CO 2 production from [1- 14 C]glucose. The two serum pools had the same stimulating effect on the Embden-Meyerhof pathway as indicated by the formation of [ 14 C]lactate from [l- 14 C]glucose. Calculations revealed that the activity in the pentose phosphate pathway was stimulated more by serum from obese, than from normal weight males. It is a possibility that increased stimulation of the pentose phosphate pathway may contribute to the development of overweight. (author)

  16. Community nurses and self-management of blood glucose.

    Science.gov (United States)

    Abbott, S; Burns, J; Gleadell, A; Gunnell, C

    2007-01-01

    Self-monitoring of blood glucose (SMBG) is commonly recommended to patients with diabetes, although the rationale for this is unclear. This small research project was designed to explore the reasons why nurses working in the community recommend SMBG. Seven interviews were carried out with community nurses caring primarily for housebound patients. Those interviewed believed that a sound evidence-base supported the recommendation that patients test their blood, but not urine, for glucose levels. Though nurses believed in the importance of patient choice and empowerment, the scope for these was limited among housebound patients. There was no evidence that patients understood how to respond to test results, or that comprehensive care planning was normal practice. Although small, this study suggests that nurses working in community settings may need to update their knowledge. It also suggests that a national debate is necessary to disseminate better the evidence about SMBG, and its implications for nursing practice.

  17. Application of chronic intravascular blood glucose sensor in dogs.

    Science.gov (United States)

    Armour, J C; Lucisano, J Y; McKean, B D; Gough, D A

    1990-12-01

    An intravenous glucose sensor was implanted in six dogs for 1-15 wk. The glucose sensor is a flexible cylinder, approximately 0.2 cm diam and 30 cm long, with a tip containing immobilized glucose oxidase and catalase coupled to a potentiostatic O2 sensor. The sensor and a similar O2 reference sensor were implanted in the superior vena cava near the entrance of the right atrium. The sensor response was conveyed externally either by a telemetry system implanted nearby, surgically accessed leads, or chronically maintained percutaneous leads. Summing over the six implants, there was a total implantation period of 333 days during which glucose sensors were functional on demand. The sensor response showed agreement with conventionally assayed blood samples after accounting for a response lag. Sensor response to glucose showed little change over the implant period. Biocompatibility, enzyme lifetime, O2 availability, O2 sensor stability, and biochemical interference were not limitations. Results demonstrated that this sensor can function effectively as an implant in dogs for a period of months and has the potential for long-term operation.

  18. The Period of Operation and Perioperative Blood Glucose ...

    African Journals Online (AJOL)

    Demographic data as well as duration of fast was obtained, blood glucose level was estimated by One touch glucometer (Life Scan Inc. USA) immediately after induction. The mean age of the children was 4.1±2.6 yr and the mean weight was 15.9±6.2 kg. The mean duration of preoperative fast was 13.1±4.2 h (5-23) h.

  19. Non-invasive Blood Glucose Quantification Using a Hybrid Sensor

    Directory of Open Access Journals (Sweden)

    Sundararajan JAYAPAL

    2009-02-01

    Full Text Available Diabetes Mellitus is a group of metabolic diseases characterized by high blood sugar (glucose levels which result from defects in insulin secretion. It is very important for the diabetics and normal people to have a correct blood glucose level. The HbA1c test is the most preferred test by renowned doctors for glucose quantification. But this test is an invasive one. At present, there are many available techniques for this purpose but these are mostly invasive or minimally non-invasive and most of these are under research. Among the different methods available, the photo acoustic (PA methods provide a reliable solution since the acoustical energy loss is much less compared to the optical or other techniques. Here a novel framework is presented for blood glucose level measurement using a combination of the HbA1c test and a PA method to get an absolutely consistent and precise, non-invasive technique. The setup uses a pulsed laser diode with pulse duration of 5-15 ns and at a repetition rate of 10 Hz as the source. The detector setup is based on the piezoelectric detection. It consists of a ring detector that includes two double ring sensors that are attached to the ring shaped module that can be worn around the finger. The major aim is to detect the photo acoustic signals from the glycated hemoglobin with the least possible error. The proposed monitoring system is designed with extreme consideration to precision and compatibility with the other computing devices. The results obtained in this research have been studied and analyzed by comparing these with those of in-vitro techniques like the HPLC. The comparison has been plotted and it shows a least error. The results also show a positive drive for using this concept as a basis for future extension in quantifying the other blood components.

  20. The effect of monosodium glutamate (MSG) on blood glucose in ...

    African Journals Online (AJOL)

    The animals were grouped into two: groups A (control) and B (Test B1 and Test B2). Group A received water and feed (grower's mash) with grass supplementation. Group B (Test B1 and B2) received 3.33mg/ml and 6.66mg/ml of MSG respectively at libitum. At the end of each week, fasting blood glucose levels were ...

  1. Association of curry consumption with blood lipids and glucose levels

    OpenAIRE

    Kwon, Youngjoo

    2016-01-01

    BACKGROUND/OBJECTIVES Curcumin, an active ingredient in turmeric, is highly consumed in South Asia. However, curry that contains turmeric as its main spice might be the major source of curcumin in most other countries. Although curcumin consumption is not as high in these countries as South Asia, the regular consumption of curcumin may provide a significant health-beneficial effect. This study evaluated whether the moderate consumption of curry can affect blood glucose and lipid levels that b...

  2. The Effect of Methanolic Extract of Otostegia persica on Serum Glucose Level and Renal Function Indicators in Streptozotocin Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Mahdiye Hedayati

    2012-05-01

    Full Text Available Background: Regarding the antioxidant property of Otostegia persica extract and the role of antioxidants in Diabetes mellitus treatment, in this study the effect of extract on serum glucose level and renal function indicators was determined in diabetic male rats. Materials and Methods: Diabetes mellitus (type I was inducted in male rats using intraperitoneal injection of streptozotocin (STZ (65 mg/kg. To determine blood glucose, urea, and creatinine serum levels; fasting blood samples were collected twice (before STZ injection and 5 days later. The rats with their serum glucose level exceeding 250 mg/dl were considered diabetic and divided into 10 groups separately received Otostegia persica alcoholic extract (100, 200, and 300 mg/kg/day doses, glibenclamide with 600 µg/kg dose and 0.5 ml distilled water for 3 and 6 days using gavage. After 3 and 6 days, blood samples were collected again and glucose, urea, and creatinine serum levels were assessed using spectrophotometry technique by respective kits.Results: Treating diabetic rats by Otostegia persica extract (100, 200, and 300 mg/kg/day doses for 6 days results in a significant decrease of glucose and creatinine, yet an increase of serum urea with 200 mg/kg dose. Also, administration of the extract for 3 days (300 mg/kg reduced glucose, and (in various doses urea and creatinine serum levels. Conclusion: Otostegia persica extract has hypoglycemic effect and administering it in diabetes mellitus not only had no undesirable renal side effects, but also improved renal function to some extent.

  3. The effects of date consumption on serumic levels of glucose, lipids and lipoproteins in diabetic rats

    Directory of Open Access Journals (Sweden)

    B Amouoghli Tabrizi

    2009-05-01

    Full Text Available Diabetes mellitus is an important problem amongst human and animals. In veterinary medicine too, diabetes mellitus occurs in many animals particularly household pets. This study was conducted in order to evaluate the effect of date consumption on serumic levels of glucose, triglyceride, cholesterol, LDL, VLDL and HDL in rats suffering from experimental diabetes mellitus. Thirty male wistar rats with the age of 8 weeks and mean body weight of 200±20 gr were selected and divided into 5 groups so that there were 6 rats per group. The groups consisted of day one healthy control, final day healthy control, healthy treatment consuming date, diabetic treatment consuming date and diabetic control group. Diabetic treatment and control groups received 100 mg/kg of alloxan subcutaneously to create experimental diabetes. The two healthy control groups also received equal amounts of normal saline solution subcutaneously. The injections were repeated a week later in all groups. After observing the diabetes symptoms including polydipsia, polyuria, glucosuria and hyperglycemia in groups that were given alloxan, feeding of healthy and diabetic treatment groups with equal ratio of date and pellet was initiated. Final day healthy control group and diabetic control group were fed only with pellet. The groups were fed for 10 days following the start of diabetes symptoms. Blood samples were collected from all groups on day 10. Evaluation of the serumic levels of glucose, cholesterol and LDL revealed statistically significant increase in diabetic control group in comparison with the healthy control groups and also in healthy and  diabetic treatment groups consuming date as compared with diabetic control and healthy groups (p

  4. Tissue glycogen and blood glucose in irradiated rats. I

    International Nuclear Information System (INIS)

    Ahlersova, E.; Ahlers, I.; Paulikova, E.; Praslicka, M.

    1980-01-01

    Fed and starved (overnight) male rats of the Wistar strain were exposed to whole-body irradiation with 14.35 Gy (1500 R) of X-rays. After irradiation and sham-irradiation all animals were starved until examination performed 1, 6, 24, 48 and 72 h after treatment. The concentration of glucose in the blood and the concentration of glycogen in the liver, heart, skeletal muscle, brown and white adipose tissue were determined. The concentrations of blood glucose and liver glycogen were found to increase between 1 and 6 h after irradiation of the starved animals. The most pronounced increase in glycogen concentration in the liver and heart muscle was observed 24 and 48 h after irradiation. A similar increase in the concentration of blood glucose was found between 48 and 72 h after irradiation. The fed and starved irradiated rats reacted differently, particularly between 48 and 72 h; the liver glycogen concentration decreased in the fed animals and remained elevated in the starved ones. Very high values of terminal glycemia were observed in both groups. The accumulation of glycogen in the heart muscle indicates that this organ is sensitive to ionizing radiation. (author)

  5. Tissue glycogen and blood glucose in irradiated rats. II

    International Nuclear Information System (INIS)

    Ahlersova, E.; Ahlers, I.; Praslicka, M.

    1980-01-01

    Male rats of the Wistar strain were continuously irradiated with 0.57 Gy (60 R) of gamma rays from a 60 Co source. Irradiation lasted from 1 to 50 days in an experimental field where also control animals shielded from radiation were placed. After a 16 h starvation, the concentration of glucose in the blood and of glycogen in the liver and the heart was determined 1, 3, 7, 14, 21, 25, 32, 39 and 50 days after the beginning of irradiation. The concentration of blood glucose in irradiated rats did not practically differ from that of control animals during the whole period of investigation. The concentration of liver glycogen in irradiated animals was higher than that in the controls during all time intervals, except for day 1. The values of glycogen in the heart muscle were approximately identical in the irradiated and control rats, except for day 21 when they sharply increased in the irradiated animals. In addition to the investigation of blood glucose and tissue glycogen during continuous irradiation, these parameters were studied immediately, and 1, 6 and 12 months after continuous irradiation with a daily exposure of 0.57 Gy (60 R) up to a total exposure of 14.35 Gy (1500 R) of gamma rays. Considerably higher values of liver glycogen were detected in the irradiated rats immediately, and 1 and 6 months after the end of irradiation. (author)

  6. Diet enriched with fresh coconut decreases blood glucose levels and body weight in normal adults.

    Science.gov (United States)

    Vijayakumar, Venugopal; Shankar, Nagashree R; Mavathur, Ramesh; Mooventhan, A; Anju, Sood; Manjunath, N K

    2018-02-20

    Background There exist controversies about the health effects of coconut. Fresh coconut consumption on human health has not been studied substantially. Fresh coconut consumption is a regular part of the diet for many people in tropical countries like India, and thus there is an increasing need to understand the effects of fresh coconut on various aspects of health. Aim To compare the effects of increased saturated fatty acid (SFA) and fiber intake, provided by fresh coconut, versus monounsaturated fatty acid (MUFA) and fiber intake, provided by a combination of groundnut oil and groundnuts, on anthropometry, serum insulin, glucose levels and blood pressure in healthy adults. Materials Eighty healthy volunteers, randomized into two groups, were provided with a standardized diet along with either 100 g fresh coconut or an equivalent amount of groundnuts and groundnut oil for a period of 90 days. Assessments such as anthropometric measurements, blood pressure, blood sugar and insulin levels were performed before and after the supplementation period. Results Results of this study showed a significant reduction in fasting blood sugar (FBS) in both the groups. However, a significant reduction in body weight was observed in the coconut group, while a significant increase in diastolic pressure was observed in the groundnut group. Conclusions Results of this study suggest that fresh coconut-added diet helps reduce blood glucose levels and body weight in normal healthy individuals.

  7. Effect of vigorous physical activity on blood lipid and glucose.

    Science.gov (United States)

    Kwon, Hyoung-Jeong; Lee, Han-Joon

    2017-12-01

    The aim of the study is to investigate how the participation of vigorous physical activities in the health examination contributes to blood lipid and blood glucose. A total of 56,810 workers from the Ulsan University Hospital in Ulsan, Subjects were tested for health checkups from February to November in 2016. The subject is those who does not have medical history, current ailments, and medication histories, and selected those who conducted the study of subjects tested to research. And this study did not consider their drinking and smoking. The final selected population was 11,557 and categorized as a vigorous physical activity of the health survey items. In this study, the group participated by the vigorous physical activity activities, group 1 (n= 70) had more than 6 days of vigorous physical activity, group 2 (n= 2,960) is 3 to 5 days of vigorous physical activity, the group 3 (n= 7,389) is 1 to 2 days of vigorous physical activity. The group 4 (n= 1,138) were classified as those who did not perform vigorous physical activity. To achieve the purpose of the study, the questionnaire examined blood lipid and blood glucose, using questions related to physical activity related to health examination in the Ulsan University Hospital. We obtained the mean and standard deviation for each group and conducted the one-way analysis of variance as an independent variable. Post hoc is least significant difference test and significant level is 0.05. Vigorous physical activity more than 3 days of participation had a positive affect high-density lipoprotein cholesterol and triglyceride. But participation in vigorous physical activity did not affect blood glucose.

  8. Association of serum orosomucoid with 30-min plasma glucose and glucose excursion during oral glucose tolerance tests in non-obese young Japanese women.

    Science.gov (United States)

    Tsuboi, Ayaka; Minato, Satomi; Yano, Megumu; Takeuchi, Mika; Kitaoka, Kaori; Kurata, Miki; Yoshino, Gen; Wu, Bin; Kazumi, Tsutomu; Fukuo, Keisuke

    2018-01-01

    Inflammatory markers are elevated in insulin resistance (IR) and diabetes. We tested whether serum orosomucoid (ORM) is associated with postload glucose, β-cell dysfunction and IR inferred from plasma insulin kinetics during a 75 g oral glucose tolerance test (OGTT). 75 g OGTTs were performed with multiple postload glucose and insulin measurements over a 30-120 min period in 168 non-obese Japanese women (aged 18-24 years). OGTT responses, serum adiponectin and high-sensitivity C reactive protein (hsCRP) were cross-sectionally analyzed by analysis of variance and then Bonferroni's multiple comparison procedure. Stepwise multivariate linear regression analyses were used to identify most important determinants of ORM. Of 168 women, 161 had normal glucose tolerance. Postload glucose levels and the area under the glucose curve (AUCg) increased in a stepwise fashion from the first through the third ORM tertile. In contrast, there was no or modest, if any, association with fat mass index, trunk/leg fat ratio, adiponectin, hsCRP, postload insulinemia, the Matsuda index and homeostasis model assessment IR. In multivariable models, which incorporated the insulinogenic index, the Matsuda index and HOMA-IR, 30 min glucose (standardized β: 0.517) and AUCg (standardized β: 0.495) explained 92.8% of ORM variations. Elevated circulating orosomucoid was associated with elevated 30 min glucose and glucose excursion in non-obese young Japanese women independently of adiposity, IR, insulin secretion, adiponectin and other investigated markers of inflammation. Although further research is needed, these results may suggest a clue to identify novel pathways that may have utility in monitoring dysglycemia within normal glucose tolerance.

  9. Effects of medetomidine and atipamezole on serum glucose and cortisol levels in captive reindeer (Rangifer tarandus tarandus

    Directory of Open Access Journals (Sweden)

    Jon M. Arnemo

    1999-04-01

    Full Text Available Serum concentrations of glucose and Cortisol were measured in five adult captive reindeer (Rangifer tarandus tarandus at 24 h and 10 min before, and at 0.5, 1,2,4, 8, 12 and 24 h after, treatment with 60 p.g/kg of medetomidine i.v. followed by 300 jig/kg of atipamezole i.v. 60 min later. The experiments were performed in January and repeated in July-August. The animals were used as their own controls and treated with saline in July-August. The wash-out period between experiments in summer was 2 weeks or more. No obvious seasonal differences were observed. Mederomidine induced a 2.5-fold increase in glucose (mean ± standard error of the mean being 15.4 ± 0.6 mmol/1 at 1 h and a 3.5-fold increase Cortisol (349 ± 28 nmol/1 at 0.5 h. Serum glucose reached control levels within 12 h, and Cortisol declined to baseline levels within 4 h after injection og medetomidine. The use of blood concentrations of glucose and Cortisol to assess nutritonal status, body condition and stress may be significantly biased in animals chemically immobilized with medetomidine or other alpha-2 adrenoceptor agonists.

  10. Acute effect of meal glycemic index and glycemic load on blood glucose and insulin responses in humans

    Directory of Open Access Journals (Sweden)

    Díaz Erik

    2006-09-01

    Full Text Available Abstract Objective Foods with contrasting glycemic index when incorporated into a meal, are able to differentially modify glycemia and insulinemia. However, little is known about whether this is dependent on the size of the meal. The purposes of this study were: i to determine if the differential impact on blood glucose and insulin responses induced by contrasting GI foods is similar when provided in meals of different sizes, and; ii to determine the relationship between the total meal glycemic load and the observed serum glucose and insulin responses. Methods Twelve obese women (BMI 33.7 ± 2.4 kg/m2 were recruited. Subjects received 4 different meals in random order. Two meals had a low glycemic index (40–43% and two had a high-glycemic index (86–91%. Both meal types were given as two meal sizes with energy supply corresponding to 23% and 49% of predicted basal metabolic rate. Thus, meals with three different glycemic loads (95, 45–48 and 22 g were administered. Blood samples were taken before and after each meal to determine glucose, free-fatty acids, insulin and glucagon concentrations over a 5-h period. Results An almost 2-fold higher serum glucose and insulin incremental area under the curve (AUC over 2 h for the high- versus low-glycemic index same sized meals was observed (p Conclusion This study showed that foods of contrasting glycemic index induced a proportionally comparable difference in serum insulin response when provided in both small and large meals. The same was true for the serum glucose response but only in large meals. Glycemic load was useful in predicting the acute impact on blood glucose and insulin responses within the context of mixed meals.

  11. Effect of Blood Glucose Fluctuation on Some Trace Elements and Aldosterone Hormone among Type II Diabetic Patients with Metabolic Syndrome

    International Nuclear Information System (INIS)

    Ezz El-Arab, A.; El Fouly, A.H.; Mahmoud, H.H.

    2014-01-01

    There is accumulating evidence determine that the metabolism of some trace elements is altered in diabetes mellitus (DM) type II. The current study aimed to evaluate the effect of serum blood glucose fluctuation during (Random, Fasting and Postprandial 2 hours state) on some trace elements such as Cadmium (Cd), Chromium (Cr), Manganese (Mn), Magnesium (Mg), Zinc (Zn), Copper (Cu), Sodium (Na), Potassium (K), and Aldosterone hormone in type II Diabetic patients associated with metabolic syndrome in comparison with healthy volunteers. The International Diabetes Federation (IFD) consensus the diagnosis of metabolic syndrome according to central obesity, lipid profile, blood glucose level and blood pressure. A significant change was observed in trace elements level (Cd, Cr, Mg, Mn, Zn, Cu, Na, and K) and Aldosterone hormone as a result of glucose fluctuation among type II diabetic patients.

  12. Solutes transport characteristics in peritoneal dialysis: variations in glucose and insulin serum levels.

    Science.gov (United States)

    da Silva, Dirceu R; Figueiredo, Ana E; Antonello, Ivan C; Poli de Figueiredo, Carlos E; d'Avila, Domingos O

    2008-01-01

    Differences in small solutes transport rate (SSTR) during peritoneal dialysis (PD) may affect water and solutes removal. Patients with high SSTR must rely on shorter dwell times and increased dialysate glucose concentrations to keep fluid balance. Glucose absorption during peritoneal dialysis (PD), besides affecting glucose and insulin metabolism, may induce weight gain. The study aimed at examining acute glucose and insulin serum level changes and other potential relationships in PD patients with diverse SSTR. This cross-sectional study used a modified peritoneal equilibration test (PET) that enrolled 34 prevalent PD patients. Zero, 15, 30, 60, 120, 180, and 240-minute glucose and insulin serum levels were measured. Insulin resistance index was assessed by the homeostasis model assessment (HOMA-IR) formula. SSTR categories were classified by quartiles of the four-hour dialysate/serum creatinine ratio (D(4)/P(Cr)). Demographic and clinical variables were evaluated, and the body mass index (BMI) was estimated. Correlations among variables of interest and categories of SSTR were explored. Glucose serum levels were significantly different at 15, 30, and 60 minutes between high and low SSTR categories (p = 0.014, 0.009, and 0.022). Increased BMI (25.5 +/- 5.1) and insulin resistance [HOMA-IR = 2.60 (1.40-4.23)] were evidenced overall. Very strong to moderate correlations between insulin levels along the PET and HOMA-IR (r = 0.973, 0.834, 0.766, 0.728, 0.843, 0.857, 0.882) and BMI (r = 0.562, 0.459, 0.417, 0.370, 0.508, 0.514, 0.483) were disclosed. CONCLUSIONS; Early glucose serum levels were associated with SSTR during a PET. Overweight or obesity and insulin resistance were prevalent. An association between insulin serum levels and BMI was demonstrated.

  13. Prognostic Significance of Blood, Serum, and Ascites Parameters in Patients with Malignant Peritoneal Mesothelioma or Peritoneal Carcinomatosis.

    Science.gov (United States)

    Su, Shan-Shan; Zheng, Guo-Qi; Yin, Wen-Jie; Liang, Yu-Fei; Liu, Ying-Ying; Song, Hui; Sun, Ning-Ning; Yang, Yu-Xin

    2018-01-01

    To determine effects of the biochemical and cytological properties of blood, serum, and ascites on survival of patients with malignant peritoneal effusion (MPeE), including malignant peritoneal mesothelioma (MPeM) and peritoneal carcinomatosis (PC), we conducted a retrospective study of patients with MPeE and healthy controls. Potential prognostic factors were identified as follows: age, sex, blood neutrophil-to-lymphocyte ratio (NLR), serum parameters, ascites parameters, serum-ascites albumin gradient, and the ascites-serum LDH ratio. Compared to those of the control group, serum albumin levels were significantly lower, and the NLR and serum LDH levels were significantly higher in the MPeE group. Overall survival (OS) was longer in patients with MPeM compared to that in patients with PC. Compared with patients in the MPeM, patients with PC had higher NLRs, ascites glucose levels, serum-ascites albumin gradients, and serum LDH levels. In contrast, their ascites albumin levels and ascites-serum LDH ratios were lower. Univariate analyses indicated that the NLR, serum LDH levels, ascites LDH levels, ascites coenocyte levels, and the ascites coenocyte-to-monocyte ratios affected the OS. Multivariate analyses identified only serum and ascites LDH levels as independent prognostic factors.

  14. Rice (Oryza sativa japonica) Albumin Suppresses the Elevation of Blood Glucose and Plasma Insulin Levels after Oral Glucose Loading.

    Science.gov (United States)

    Ina, Shigenobu; Ninomiya, Kazumi; Mogi, Takashi; Hase, Ayumu; Ando, Toshiki; Matsukaze, Narumi; Ogihara, Jun; Akao, Makoto; Kumagai, Hitoshi; Kumagai, Hitomi

    2016-06-22

    The suppressive effect of rice albumin (RA) of 16 kDa on elevation of blood glucose level after oral loading of starch or glucose and its possible mechanism were examined. RA suppressed the increase in blood glucose levels in both the oral starch tolerance test and the oral glucose tolerance test. The blood glucose concentrations 15 min after the oral administration of starch were 144 ± 6 mg/dL for control group and 127 ± 4 mg/dL for RA 200 mg/kg BW group, while those after the oral administration of glucose were 157 ± 7 mg/dL for control group and 137 ± 4 mg/dL for RA 200 mg/kg BW group. However, in the intraperitoneal glucose tolerance test, no significant differences in blood glucose level were observed between RA and the control groups, indicating that RA suppresses the glucose absorption from the small intestine. However, RA did not inhibit the activity of mammalian α-amylase. RA was hydrolyzed to an indigestible high-molecular-weight peptide (HMP) of 14 kDa and low-molecular-weight peptides by pepsin and pancreatin. Furthermore, RA suppressed the glucose diffusion rate through a semipermeable membrane like dietary fibers in vitro. Therefore, the indigestible HMP may adsorb glucose and suppress its absorption from the small intestine.

  15. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin-converti......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin......-converting enzyme (ACE) blockade] or without (control) administration of the ACE inhibitor enalapril (10 mg iv). Splanchnic blood flow was estimated by indocyanine green, and splanchnic substrate exchange was determined by the arteriohepatic venous difference. Exercise led to an approximately 20-fold increase (P ...-blockade group vs. the control group, hormones, metabolites, VO(2), and RER followed the same pattern of changes in ACE-blockade and control groups during exercise. Splanchnic blood flow (at rest: 1.67 +/- 0.12, ACE blockade; 1.59 +/- 0.18 l/min, control) decreased during moderate exercise (0.78 +/- 0.07, ACE...

  16. Decreased serum glucose and glycosylated hemoglobin levels in patients with Chuvash polycythemia: a role for HIF in glucose metabolism

    Science.gov (United States)

    McClain, Donald A.; Abuelgasim, Khadega A.; Nouraie, Mehdi; Salomon-Andonie, Juan; Niu, Xiaomei; Miasnikova, Galina; Polyakova, Lydia A.; Sergueeva, Adelina; Okhotin, Daniel J.; Cherqaoui, Rabia; Okhotin, David; Cox, James E.; Swierczek, Sabina; Song, Jihyun; Simon, M.Celeste; Huang, Jingyu; Simcox, Judith A.; Yoon, Donghoon; Prchal, Josef T.; Gordeuk, Victor R.

    2012-01-01

    In Chuvash polycythemia, a homozygous 598C>T mutation in the von Hippel-Lindau gene (VHL) leads to an R200W substitution in VHL protein, impaired degradation of α-subunits of hypoxia inducible factor (HIF)-1 and HIF-2, and augmented hypoxic responses during normoxia. Chronic hypoxia of high altitude is associated with decreased serum glucose and insulin concentrations. Other investigators reported that HIF-1 promotes cellular glucose uptake by increased expression of GLUT1 and increased glycolysis by increased expression of enzymes such as PDK. On the other hand, inactivation of Vhl in murine liver leads to hypoglycemia associated with a HIF-2-related decrease in the expression of the gluconeogenic enzymes genes Pepck, G6pc, and Glut2. We therefore hypothesized that glucose concentrations are decreased in individuals with Chuvash polycythemia. We found that 88 Chuvash VHLR200W homozygotes had lower random glucose and glycosylated hemoglobin A1c levels than 52 Chuvash subjects with wildtype VHL alleles. Serum metabolomics revealed higher glycerol and citrate levels in the VHLR200W homozygotes. We expanded these observations in VHLR200W homozygote mice and found that they had lower fasting glucose values and lower glucose excursions than wild-type control mice but no change in fasting insulin concentrations. Hepatic expression of Glut2 and G6pc but not Pdk2 was decreased and skeletal muscle expression of Glut1, Pdk1 and Pdk4 was increased. These results suggest that both decreased hepatic gluconeogenesis and increased skeletal uptake and glycolysis contribute to the decreased glucose concentrations. Further study is needed to determine whether pharmacologically manipulating HIF expression might be beneficial for treatment of diabetic patients. PMID:23015148

  17. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  18. Clinical assessment of blood glucose homeostasis in horses: comparison of a continuous glucose monitoring system with a combined intravenous glucose and insulin test protocol.

    Science.gov (United States)

    Johnson, P J; Wiedmeyer, C E; LaCarrubba, A; Messer, N T; Dingfelder, H A; Cogswell, A M; Amorim, J R R; Ganjam, V K

    2011-01-01

    The combined glucose-insulin test (CGIT) is helpful for evaluating insulin sensitivity. A continuous glucose monitoring system (CGMS) reports changes in interstitial glucose concentrations as they occur in the blood. Use of the CGMS minimizes animal contact and may be useful when performing a CGIT. Results obtained using a CGMS are useful for the evaluation of glucose responses during the evaluation of insulin sensitivity in equids. Seven mature, obese ponies. Ponies were equipped with CGMS for determination of interstitial glucose concentrations. Glucose (150 mg/kg, i.v.) and insulin (0.1 U/kg, i.v.) were administered and blood glucose concentrations determined at (minutes after time zero) 1, 5, 15, 25, 35, 45, 60, 75, 90, 105, and 120 with a hand-held glucometer. Blood chemistry results were compared with simultaneously obtained results using CGMS. Concordance coefficients determined for comparison of blood glucose concentrations determined by a hand-held glucometer and those determined by CGMS after the zero time point were 0.623, 0.764, 0.834, 0.854, and 0.818 (for delays of 0, 5, 10, 15, and 20 minutes, respectively). Interstitial glucose concentrations obtained by the CGMS compared favorably to blood glucose concentrations. CGMS may be useful for assessment of glucose dynamics in the CGIT. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  19. Peripheral Blood Transcriptomic Signatures of Fasting Glucose and Insulin Concentrations

    Science.gov (United States)

    Chen, Brian H.; Hivert, Marie-France; Peters, Marjolein J.; Pilling, Luke C.; Hogan, John D.; Pham, Lisa M.; Harries, Lorna W.; Fox, Caroline S.; Bandinelli, Stefania; Dehghan, Abbas; Hernandez, Dena G.; Hofman, Albert; Hong, Jaeyoung; Joehanes, Roby; Johnson, Andrew D.; Munson, Peter J.; Rybin, Denis V.; Singleton, Andrew B.; Uitterlinden, André G.; Ying, Saixia; Melzer, David; Levy, Daniel; van Meurs, Joyce B.J.; Ferrucci, Luigi; Florez, Jose C.; Dupuis, Josée

    2016-01-01

    Genome-wide association studies (GWAS) have successfully identified genetic loci associated with glycemic traits. However, characterizing the functional significance of these loci has proven challenging. We sought to gain insights into the regulation of fasting insulin and fasting glucose through the use of gene expression microarray data from peripheral blood samples of participants without diabetes in the Framingham Heart Study (FHS) (n = 5,056), the Rotterdam Study (RS) (n = 723), and the InCHIANTI Study (Invecchiare in Chianti) (n = 595). Using a false discovery rate q fasting glucose and 433 transcripts associated with fasting insulin levels after adjusting for age, sex, technical covariates, and complete blood cell counts. Among the findings, circulating IGF2BP2 transcript levels were positively associated with fasting insulin in both the FHS and RS. Using 1000 Genomes–imputed genotype data, we identified 47,587 cis-expression quantitative trait loci (eQTL) and 6,695 trans-eQTL associated with the 433 significant insulin-associated transcripts. Of note, we identified a trans-eQTL (rs592423), where the A allele was associated with higher IGF2BP2 levels and with fasting insulin in an independent genetic meta-analysis comprised of 50,823 individuals. We conclude that integration of genomic and transcriptomic data implicate circulating IGF2BP2 mRNA levels associated with glucose and insulin homeostasis. PMID:27625022

  20. Blood and serum biochemistry of omentopexed West African Dwarf ...

    African Journals Online (AJOL)

    This study investigated the blood and serum biochemistry following peritoneum sutured and not sutured techniques of laparotomy sutures in omentopexed WAD goats. Twentyfive male WAD goats were randomly divided into 5 groups (A – E). In group A, peritoneum was not sutured, while in group B, the peritoneum was ...

  1. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  2. Effects of exposure to electromagnetic field radiation (EMFR generated by activated mobile phones on fasting blood glucose

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2013-04-01

    Full Text Available Objective: Extensive use of mobile phones has been accompanied by a common public debate about possible adverse effects on human health. No study has been published so far to establish any association between the fastest growing innovation of mobile phone and fasting blood glucose. The aim was to determine the effects of exposure to electromagnetic field radiation generated by mobile phones on fasting blood glucose in Wistar Albino rats. Materials and Methods: 40 Male Albino rats (Wistar Strain were divided into 5 equally numerous groups. Group A served as the control one, group B received mobile phone radiation for less than 15 min/day, group C: 15-30 min/day, group D: 31-45 min/day, and group E: 46-60 min/day for a total period of 3 months. Fasting blood glucose was determined by using Spectrophotometer and serum insulin by Enzyme-linked Immunosorbent Assay (ELISA. The Homeostatic Model (HOMA-B was applied for the assessment of β-cell function and (HOMA-IR for resistance to insulin. Results: Wister Albino rats exposed to mobile phone radiation for longer than 15 min a day for a total period of 3 months had significantly higher fasting blood glucose (p < 0.015 and serum insulin (p < 0.01 compared to the control group. HOMA-IR for insulin resistance was significantly increased (p < 0.003 in the groups that were exposed for 15-30 and 46-60 min/day compared to the control rats. Conclusion: The results of the present study show an association between long-term exposure to activated mobile phones and increase in fasting blood glucose and serum insulin in Albino rats.

  3. Selected Blood Serum Elements in Van (Turkey Cats

    Directory of Open Access Journals (Sweden)

    V. Altunok

    2007-01-01

    Full Text Available The Turkish Van cat originates from eastern Turkey. One of the characteristic features of Van cats is the colour of their eyes, which can be both eyes blue, both eyes amber or one eye blue and the other amber. Serum essential trace, macro and industrial element concentrations of Van cats (n = 47 according to sex, age, hair length and eye colour differences were investigated. Serum aluminium, arsenic, boron, barium, cobalt, chromium, copper, gallium, indium, iron, lead, lithium, manganese, nickel, selenium, silver, sulphur, strontium, vanadium and zinc were measured with ICP-OES plasma optical atomic emission spectrometer. In result, serum aluminium, barium, copper, manganese and strontium levels in male cats were found higher (p p p p > 0.05 found in the age and hair length groups. Our results indicate that several of the blood serum elements of Van cats may be related to their eye colours and sex differences.

  4. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  5. Effects of blood glucose, blood lipids and blood pressure control on recovery of patients with gastric cancer complicated with metabolic syndrome after radical gastrectomy.

    Science.gov (United States)

    Sun, Li; Zhou, Pingping; Hua, Qingli; Jin, Changming; Guo, Chunling; Song, Bing

    2018-06-01

    This study aimed to investigate the effects of blood glucose, blood lipids and blood pressure control on recovery of patients with gastric cancer complicated with metabolic syndrome (MS) after radical gastrectomy. A total of 150 patients with gastric cancer, who were treated in Daqing Longnan Hospital from November, 2015 to May, 2017, were enrolled in this study. The patients were divided into the MS group (80 cases) and non-MS group (70 cases). Patients in the MS group were given corresponding drugs to control blood pressure, blood lipids and blood glucose, while patients in the non-MS group were not treated with those drugs. Patients in the MS group were divided into the normal and abnormal groups according to the levels of blood glucose, blood lipids and blood pressure. Moreover, occurrences of complications were compared between the normal and abnormal groups. Before surgery, blood glucose, blood lipids and blood pressure in the MS group were significantly higher than those in the non-MS group (pblood glucose, blood lipids and blood pressure of the MS group decreased significantly compared to those before operation (pblood glucose, 2 h postprandial blood glucose, glycosylated hemoglobin, total triglycerides (TGs), LDL, mean blood pressure and BMI (pblood glucose, blood lipids and blood pressure in patients with gastric cancer complicated with MS after radical gastrectomy can reduce the incidence of postoperative complications and promote postoperative recovery.

  6. Circulating Glucagon 1-61 Regulates Blood Glucose by Increasing Insulin Secretion and Hepatic Glucose Production

    Directory of Open Access Journals (Sweden)

    Nicolai J. Wewer Albrechtsen

    2017-11-01

    Full Text Available Glucagon is secreted from pancreatic α cells, and hypersecretion (hyperglucagonemia contributes to diabetic hyperglycemia. Molecular heterogeneity in hyperglucagonemia is poorly investigated. By screening human plasma using high-resolution-proteomics, we identified several glucagon variants, among which proglucagon 1-61 (PG 1-61 appears to be the most abundant form. PG 1-61 is secreted in subjects with obesity, both before and after gastric bypass surgery, with protein and fat as the main drivers for secretion before surgery, but glucose after. Studies in hepatocytes and in β cells demonstrated that PG 1-61 dose-dependently increases levels of cAMP, through the glucagon receptor, and increases insulin secretion and protein levels of enzymes regulating glycogenolysis and gluconeogenesis. In rats, PG 1-61 increases blood glucose and plasma insulin and decreases plasma levels of amino acids in vivo. We conclude that glucagon variants, such as PG 1-61, may contribute to glucose regulation by stimulating hepatic glucose production and insulin secretion.

  7. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

    Science.gov (United States)

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-12-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery-powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring.

  8. Asymptotic tracking and disturbance rejection of the blood glucose regulation system.

    Science.gov (United States)

    Ashley, Brandon; Liu, Weijiu

    2017-07-01

    Type 1 diabetes patients need external insulin to maintain blood glucose within a narrow range from 65 to 108 mg/dl (3.6 to 6.0 mmol/l). A mathematical model for the blood glucose regulation is required for integrating a glucose monitoring system into insulin pump technology to form a closed-loop insulin delivery system on the feedback of the blood glucose, the so-called "artificial pancreas". The objective of this paper is to treat the exogenous glucose from food as a glucose disturbance and then develop a closed-loop feedback and feedforward control system for the blood glucose regulation system subject to the exogenous glucose disturbance. For this, a mathematical model for the glucose disturbance is proposed on the basis of experimental data, and then incorporated into an existing blood glucose regulation model. Because all the eigenvalues of the disturbance model have zero real parts, the center manifold theory is used to establish blood glucose regulator equations. We then use their solutions to synthesize a required feedback and feedforward controller to reject the disturbance and asymptotically track a constant glucose reference of 90  mg/dl. Since the regulator equations are nonlinear partial differential equations and usually impossible to solve analytically, a linear approximation solution is obtained. Our numerical simulations show that, under the linear approximate feedback and feedforward controller, the blood glucose asymptotically tracks its desired level of 90 mg/dl approximately. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Associations of Body Composition Measurements with Serum Lipid, Glucose and Insulin Profile: A Chinese Twin Study

    Science.gov (United States)

    Liao, Chunxiao; Gao, Wenjing; Cao, Weihua; Lv, Jun; Yu, Canqing; Wang, Shengfeng; Zhou, Bin; Pang, Zengchang; Cong, Liming; Wang, Hua; Wu, Xianping; Li, Liming

    2015-01-01

    Objectives To quantitate and compare the associations of various body composition measurements with serum metabolites and to what degree genetic or environmental factors affect obesity-metabolite relation. Methods Body mass index (BMI), waist circumference (WC), lean body mass (LBM), percent body fat (PBF), fasting serum high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C), triglycerides (TG), total cholesterol (TC), glucose, insulin and lifestyle factors were assessed in 903 twins from Chinese National Twin Registry (CNTR). Homeostasis model assessment of insulin resistance (HOMA-IR) was calculated from fasting serum glucose and insulin. Linear regression models and bivariate structural equation models were used to examine the relation of various body composition measurements with serum metabolite levels and genetic/environmental influences on these associations, respectively. Results At individual level, adiposity measurements (BMI, WC and PBF) showed significant associations with serum metabolite concentrations in both sexes and the associations still existed in male twins when using within-MZ twin pair comparison analyses. Associations of BMI with TG, insulin and HOMA-IR were significantly stronger in male twins compared to female twins (BMI-by-sex interaction p = 0.043, 0.020 and 0.019, respectively). Comparison of various adiposity measurements with levels of serum metabolites revealed that WC explained the largest fraction of variance in serum LDL-C, TG, TC and glucose concentrations while BMI performed best in explaining variance in serum HDL-C, insulin and HOMA-IR levels. Of these phenotypic correlations, 64–81% were attributed to genetic factors, whereas 19–36% were attributed to unique environmental factors. Conclusions We observed different associations between adiposity and serum metabolite profile and demonstrated that WC and BMI explained the largest fraction of variance in serum lipid profile and insulin

  10. Proportional Insulin Infusion in Closed-Loop Control of Blood Glucose

    NARCIS (Netherlands)

    Grasman, Johan; Callender, Hannah L.; Mensink, Marco; Pietropaolo, Massimo

    2017-01-01

    A differential equation model is formulated that describes the dynamics of glucose concentration in blood circulation. The model accounts for the intake of food, expenditure of calories and the control of glucose levels by insulin and glucagon. These and other hormones affect the blood glucose level

  11. Circulating Glucagon 1-61 Regulates Blood Glucose by Increasing Insulin Secretion and Hepatic Glucose Production

    DEFF Research Database (Denmark)

    Wewer Albrechtsen, Nicolai J.; Kuhre, Rune E.; Hornburg, Daniel

    2017-01-01

    that PG 1-61 dose-dependently increases levels of cAMP, through the glucagon receptor, and increases insulin secretion and protein levels of enzymes regulating glycogenolysis and gluconeogenesis. In rats, PG 1-61 increases blood glucose and plasma insulin and decreases plasma levels of amino acids in......Glucagon is secreted from pancreatic α cells, and hypersecretion (hyperglucagonemia) contributes to diabetic hyperglycemia. Molecular heterogeneity in hyperglucagonemia is poorly investigated. By screening human plasma using high-resolution-proteomics, we identified several glucagon variants, among...... which proglucagon 1-61 (PG 1-61) appears to be the most abundant form. PG 1-61 is secreted in subjects with obesity, both before and after gastric bypass surgery, with protein and fat as the main drivers for secretion before surgery, but glucose after. Studies in hepatocytes and in β cells demonstrated...

  12. Continuous Glucose Monitoring (CGM) or Blood Glucose Monitoring (BGM): Interactions and Implications.

    Science.gov (United States)

    Heinemann, Lutz

    2018-04-01

    At the 2017 10th annual International Conference on Advanced Technologies and Treatments for Diabetes (ATTD) in Paris, France, four speakers presented their perspectives on the roles of continuous glucose monitoring (CGM) and of blood glucose monitoring (BGM) in patient management within one symposium. These presentations included discussions of the differences in the accuracy of CGM and BGM, a clinical perspective on the physiological reasons behind differences in CGM and BGM values, and an overview of the impact of variations in device accuracy on patients with diabetes. Subsequently a short summary of these presentations is given, highlighting the value of good accuracy of BGM or CGM systems and the ongoing need for standardization. The important role of both BGM and CGM in patient management was a theme across all presentations.

  13. Serum galectin-1 levels are positively correlated with body fat and negatively with fasting glucose in obese children.

    Science.gov (United States)

    Acar, Sezer; Paketçi, Ahu; Küme, Tuncay; Tuhan, Hale; Gürsoy Çalan, Özlem; Demir, Korcan; Böber, Ece; Abacı, Ayhan

    2017-09-01

    Galectin-1, a recently identified peptide, is primarily released from the adipose tissue. Although galectin-1 was shown to have an anti-inflammatory effect, its specific function is not clearly understood. We aimed to evaluate the relationship of serum galectin-1 levels with clinical and laboratory parameters in childhood obesity. A total of 45 obese children (mean age: 12.1±3.1years) and 35 normal-weight children (mean age: 11.8±2.2years) were enrolled. Clinical [body mass index (BMI), waist circumference (WC), percentage of body fat and blood pressure] and biochemical [glucose, insulin, lipids, galectin-1, high-sensitive C-reactive protein (hsCRP) and leptin levels] parameters were assessed. Serum galectin-1, hsCRP and leptin levels were significantly higher in obese children than those in normal-weight children (12.4 vs 10.2ng/mL, pobese children, galectin-1 levels correlated negatively with fasting glucose (r=-0.346, p=0.020) and positively with fat mass (r=0.326, p=0.026) and WC standard deviation score (SDS) (r=0.451, p=0.002). The multivariate regression analysis demonstrated that serum galectin-1 levels were significantly associated with fasting glucose and WC SDS. This study showed that obese children had significantly higher galectin-1 levels in proportion to fat mass in obese cases than those in healthy children, which may be interpreted as a compensatory increase in an attempt to improve glucose metabolism. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Effect of Urtica Dioica Decoction on Serum Glucose and Lipid Profile in Stereptozotocin Induced Diabetic Male Rats

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sahraki

    Full Text Available Background: Since Urtica dioica is a traditional treatment plant and is used for antihypertensive, antilipidemic and antidiabetic agents, this survey was carried out to evaluate the effect of Urtica dioica decoction on serum glucose and lipid profile in diabetic male rats induced by stereptozotocin (STZ. Materials and Methods: This experiment was performed on 30 Wistar-Albino male rats, weighing 200-250 g, which were divided in sham control (A, diabetic control (B and diabetic test groups (C randomly (N=10. Type I diabetes was induced by single intraperitoneal injection of STZ (65 mg/kg. Test group received 0.40-0.60 ml of Urtica dioica decoction for a month by gavages, control group (B received the same volume of distill water. Group (A did not receive any agent during the experiment period. Finally, animals were anesthetized, sacrificed and blood samples were collected from the cervical vein. Then, serum glucose and lipid profiles were measured by ordinary methods. Data were analyzed by SPSS-11, using ANOVA and post hoc Tukey tests. Results were expressed as mean±SD, and statistical difference was considered significant by p<0.05.Results: Results in the present study showed that fasting blood glucose (FBS, total cholesterol (TCho, triglyceride (TG, LDL, food and water intake were significantly decreased in group C compared with those of group B, but body weight gain was significantly increased compared with that of control group (B.Conclusion: These results indicated that Urtica dioica decoction caused decreased FBS and improved serum lipids in diabetic male rats. Some more studies have shown the same mechanism.

  15. Intracerebroventricular Kainic Acid-Induced Damage Affects Blood Glucose Level in d-glucose-fed Mouse Model.

    Science.gov (United States)

    Kim, Chea-Ha; Hong, Jae-Seung

    2015-03-01

    We have previously reported that the intracerebroventricular (i.c.v.) administration of kainic acid (KA) results in significant neuronal damage on the hippocampal CA3 region. In this study, we examined possible changes in the blood glucose level after i.c.v. pretreatment with KA. The blood glucose level was elevated at 30 min, began to decrease at 60 min and returned to normal at 120 min after D-glucose-feeding. We found that the blood glucose level in the KA-pretreated group was higher than in the saline-pretreated group. The up-regulation of the blood glucose level in the KA-pretreated group was still present even after 1~4 weeks. The plasma corticosterone and insulin levels were slightly higher in the KA-treated group. Corticosterone levels decreased whereas insulin levels were elevated when mice were fed with D-glucose. The i.c.v. pretreatment with KA for 24 hr caused a significant reversal of D-glucose-induced down-regulation of corticosterone level. However, the insulin level was enhanced in the KA-pretreated group compared to the vehicle-treated group when mice were fed with D-glucose. These results suggest that KA-induced alterations of the blood glucose level are related to cell death in the CA3 region whereas the up-regulation of blood glucose level in the KA-pretreated group appears to be due to a reversal of D-glucose feeding-induced down-regulation of corticosterone level.

  16. Prognostic value of low blood glucose at the presentation of E. coli bacteremia.

    Science.gov (United States)

    Alamgir, Shamsuddin; Volkova, Natalia B; Peterson, Michael W

    2006-11-01

    Septicemia is the tenth leading cause of death in the United States, and Escherichia coli is the most common isolate in blood cultures. Low blood glucose is a known complication of sepsis. The prognostic role of low blood glucose in E. coli bacteremia is unknown. The study's objective was to identify the incidence of low blood glucose at the presentation of E. coli bacteremia and determine its influence on prognosis and outcome. A retrospective cohort study was conducted in university-affiliated community hospitals. Subjects were consecutive patients diagnosed with E. coli bacteremia between 1997 and 2003. We identified 1060 patients with documented E. coli bacteremia. We excluded 105 patients who were younger than 18 years old or pregnant. We recorded demographic characteristics, discharge diagnosis, and outcome. Among the 955 patients with E. coli bacteremia, the average age was 64+/-19.4 years. Overall, 4.6% had documented low blood glucose (blood glucose <70 mg/dL) at presentation. The incidence of low blood glucose was the same in diabetic and nondiabetic patients. Patients with low blood glucose had a 4.7 times higher risk of death compared to patients with non-low blood glucose. Race, age, sex, and diabetes had no influence on survival. Gastrointestinal and genitourinary sources for E. coli bacteremia were more commonly associated with low blood glucose (P <.001). The study was limited to E. coli-positive blood cultures and to the one hospital system. Low blood glucose is present at the onset of E. coli bacteremia in 4.6% of patients. This represents a potentially large number of patients because E. coli is the most common blood culture isolate. Low blood glucose predicts poor outcome, especially in patients with abnormal hepatic and renal function. Low blood glucose should be considered an early clinical sign of E. coli bacteremia and aggressive therapy should be instituted to potentially save lives.

  17. Significant association of serum creatinine with HbA1C in impaired glucose tolerant Pakistani subjects.

    Science.gov (United States)

    Farasat, Tasnim; Sharif, Saima; Naz, Shagufta; Fazal, Sabiha

    2015-01-01

    The present study was conducted to assess the serum concentration of creatinine and determine its relationship with potential risk factors of diabetes in Impaired Glucose tolerance subjects. This cross sectional study was conducted on 100 IGT patients who attended Amin Hayat diabetic center in Lahore from January 2011- June 2011. Patients with age group 34-67 years, (both sexes) were included in the study. Different demographic parameters as age, BMI, WHR, B.P, personal history and socioeconomic status were recorded. Oral Glucose Tolerance Test was performed. The biochemical parameters including HbA1c, lipid profile, urea, uric acid, creatinine and bilirubin level were measured by chemistry analyzer. A strong correlation between creatinine and HbA1c was observed. The level of creatinine was also significantly associated with age in IGT subjects. Creatinine is non-significantly correlated with Cholesterol, LDL-Chol and TG while negatively significantly associated with BMI, fasting blood glucose and HDL-Chol. The present study concluded significant association of serum creatinine with HbA1c, BMI and HDL cholesterol.

  18. Effects of ginger on serum glucose, advanced glycation end products, and inflammation in peritoneal dialysis patients.

    Science.gov (United States)

    Imani, Hossein; Tabibi, Hadi; Najafi, Iraj; Atabak, Shahnaz; Hedayati, Mehdi; Rahmani, Leila

    2015-05-01

    The aim of this study was to investigate the effects of ginger supplementation on serum glucose, advanced glycation end products, oxidative stress, and systemic and vascular inflammatory markers in patients on peritoneal dialysis (PD). In this randomized, double-blind, placebo-controlled trial, 36 patients on PD were randomly assigned to either the ginger or the placebo group. The patients in the ginger group received 1000 mg/d ginger for 10 wk, whereas the placebo group received corresponding placebos. At baseline and the end of week 10, serum concentrations of glucose, carboxymethyl lysine, pentosidine, malondialdehyde (MDA), high-sensitivity C-reactive protein (hs-CRP), soluble intercellular adhesion molecule type 1 (sICAM-1), soluble vascular cell adhesion molecule type 1 (sVCAM-1), and sE-selectin were measured after a 12- to 14-h fast. Serum fasting glucose decreased significantly up to 20% in the ginger group at the end of week 10 compared with baseline (P ginger reduces serum fasting glucose, which is a risk factor for hyperinsulinemia, dyslipidemia, peritoneal membrane fibrosis, and cardiovascular disease, in patients on PD. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Physiocochemical properties of blood serum proteins of coal miners

    Energy Technology Data Exchange (ETDEWEB)

    Nandakova, V N; Zemliakova, L F; Sukhanov, V V; Min' ko, L A

    1979-07-01

    Using disk electrophoresis in the polyacrylamide gel, blood serum proteins were studied in miners working under conditions of the combine (the control group) and drilling-and-blasting (the contact with carbon oxide, nitrogen oxides) driving technique under normal temperature conditions. 26 to 27 protein fractions characterized by mobility, thermolability under definite conditions of the experiment and the contitative content were obtained. It is shown that the contact with carbon oxide and nitrogen oxides causes changes in the properties of certain proteins (II3, globulins - 2 alpha 1, 3 alpha 1, 2 beta, 2 alpha 2, 5 alpha 2, 6 alpha 2, 7 alpha 2) of miners' blood serum. Some of these proteins are supposed to participate in the adaptation reactions of the organism.

  20. A Study on the Correlation between Cord Blood Glucose Level and the Apgar Score.

    Science.gov (United States)

    Khan, Kalyan; Saha, Ashis Ranjan

    2013-02-01

    The study of the biochemical parameters of cord blood acts as a mirror, which usually reflects the neonatal status. The widely used system for the evaluation of a neonate is the Apgar score. There is no comprehensive published data which has established the association between the cord blood glucose level and the Apgar score. Similarly, there is also no well accepted reference range of the cord blood glucose level. The main objectives of the present study was to ascertain any adverse effects of an abnormal cord blood glucose level on the neonatal status and to find out a standard reference level of glucose in cord blood. The cord blood glucose estimation was done by using the glucose oxidase peroxidase method and the statistical analysis was performed by using the SPSS, version 16 software. In the present study, the cord blood glucose level was found to have no correlation with the Apgar scores which were calculated at both one minute and five minutes after birth. It was also found that for the foetus to be free from any obvious complication, the cord blood glucose level had to be around 87 mg/dl. The fluctuations in the maternal glucose levels are weakly associated with the glucose level in the cord blood.

  1. Correlation between high blood IL-6 level, hyperglycemia, and glucose control in septic patients.

    Science.gov (United States)

    Nakamura, Masataka; Oda, Shigeto; Sadahiro, Tomohito; Watanabe, Eizo; Abe, Ryuzo; Nakada, Taka-Aki; Morita, Yasumasa; Hirasawa, Hiroyuki

    2012-12-12

    The aim of the present study was to investigate the relationship between the blood IL-6 level, the blood glucose level, and glucose control in septic patients. This retrospective observational study in a general ICU of a university hospital included a total of 153 patients with sepsis, severe sepsis, or septic shock who were admitted to the ICU between 2005 and 2010, stayed in the ICU for 7 days or longer, and did not receive steroid therapy prior to or after ICU admission. The severity of stress hyperglycemia, status of glucose control, and correlation between those two factors in these patients were investigated using the blood IL-6 level as an index of hypercytokinemia. A significant positive correlation between blood IL-6 level and blood glucose level on ICU admission was observed in the overall study population (n = 153; r = 0.24, P = 0.01), and was stronger in the nondiabetic subgroup (n = 112; r = 0.42, P glucose control (blood glucose level blood IL-6 level on ICU admission (P blood IL-6 level after ICU admission remained significantly higher and the 60-day survival rate was significantly lower in the failed glucose control group than in the successful glucose control group (P blood IL-6 level was correlated with hyperglycemia and with difficulties in glucose control in septic patients. These results suggest the possibility that hypercytokinemia might be involved in the development of hyperglycemia in sepsis, and thereby might affect the success of glucose control.

  2. Serum neopterin: a potential marker for screening blood donors

    International Nuclear Information System (INIS)

    Ashfaq, A.; Ejaz, A.; Abbas, G.

    2017-01-01

    To determine serum neopterin levels in blood donors of local population and its association with transfusion ransmitted infections. Study Design: A cross-sectional observational study. Place and Duration of Study:Department of Physiology, Liaquat National Hospital and Medical College (LNHMC) in collaboration with Basic Medical Sciences Institute (BMSI) and Jinnah Postgraduate Medical Centre (JPMC), Blood Bank, Karachi, Pakistan, from January to June 2015. Methodology: During this period, a total of 174 blood donors were selected through random sampling technique. All participants fulfilling the inclusion criteria involving apparently healthy blood donors of either gender within the age bracket of 18 - 60 years and consenting to participate were selected. The participants were screened for transfusion transmitted infections as per WHO recommendations through the standard procedures used for screening at the JPMC blood bank. The demographic profile, anthropometric measurements and vitals were recorded for every participant. Serum neopterin was measured using ELISA kits. Data was analysed on SPSS version 21. ANOVA and chi-square tests were applied as tests of significance at a p-value of <0.05. Results: The neopterin content in the sera of disease negative blood donors was 6.23 +-2.19 nmol/l as compared to disease positive blood donors, in whom the neopterin level was increased to 15.10 +-4.93 nmol/l (p =0.001). Conclusion: The neopterin assay has the potential to detect a number of transfusion transmissible viral diseases; which may, or may not be revealed by the usually employed battery of routine tests. We conclude that the risk of transfusion transmitted pathogens in our population can be reduced significantly, using neopterin assay as a routine in blood banks. (author)

  3. A meal replacement regimen improves blood glucose levels in prediabetic healthy individuals with impaired fasting glucose.

    Science.gov (United States)

    König, Daniel; Kookhan, Sadaf; Schaffner, Denise; Deibert, Peter; Berg, Aloys

    2014-01-01

    The aim of this study was to investigate the effect of a 6-wk intervention with either lifestyle intervention (increased physical activity and a low-calorie diet) or a meal replacement regimen on glycemic control in patients who are prediabetic and have impaired fasting glucose. Forty-two overweight or obese men and women (age 54 ± 8 y; weight 95.1 ± 11.9 kg; body mass index [BMI] 32.8 ± 2.89 kg/m(2)) were included in this randomized controlled clinical trial. Patients in the lifestyle group (LS; n = 14) received dietary counseling sessions (fat-restricted low-calorie diet) and instructions on how to increase physical activity. Patients in the meal replacement group (MR; n = 28) were instructed to replace two daily meals with a low-calorie, high soy-protein drink with a low glycemic index. Both interventions resulted in a significant decrease in body weight and BMI, although the reduction was more pronounced (P meal replacement is an effective intervention for rapid improvement of elevated fasting glucose and increased insulin concentrations, these being important biomarkers of the prediabetic state. The 6-wk intervention has shown that the effect of meal replacement on fasting blood glucose was comparable to the effect of lifestyle intervention. The alterations in BMI, insulin, and HOMA-IR were significantly more pronounced following the meal replacement regimen. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Effect of Consumption of Tribulus Terrestris on Serum Glucose and Lipid Levels in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    M Roghani

    2010-03-01

    Full Text Available Introduction: The effect of Tribulus terrestris (TT on serum glucose and lipid levels was investigated in an experimental model of diabetes mellitus in rats. Methods: Female Wistar rats were divided into control, TT-treated control, diabetic, glibenclamide-treated, and TT-treated diabetic groups. For induction of diabetes, streptozotcin (STZ was administered (60 mg/Kg. Meanwhile, TT-treated groups received TT mixed with standard pelleted food at a weight ratio of 6.25% for 6 weeks. Serum glucose and lipid levels were determined before the study and at the 3rd and 4th week after the study. Results: Serum glucose was significantly lower in TT-treated diabetic rats at 3rd and 6th weeks as compared to untreated diabetics (p<0.01 and p<0.005, respectively. In addition, serum total cholesterol, triglyceride, and LDL-cholesterol showed a significant reduction in TT-treated diabetic rats as compared to untreated diabetics (p<0.05. On the other hand, HDL-cholesterol level did not change significantly in TT-treated diabetic group as compared to untreated diabetic group. Conclusions: Oral administration of TT has a significant hypoglycemic effect and in long term leads to appropriate changes in serum LDL-cholesterol, total cholesterol, and triglyceride levels, but does not affect HDL-cholesterol levels in diabetic rats.

  5. Serum deprivation induces glucose response and intercellular coupling in human pancreatic adenocarcinoma PANC-1 cells.

    Science.gov (United States)

    Hiram-Bab, Sahar; Shapira, Yuval; Gershengorn, Marvin C; Oron, Yoram

    2012-03-01

    This study aimed to investigate whether the previously described differentiating islet-like aggregates of human pancreatic adenocarcinoma cells (PANC-1) develop glucose response and exhibit intercellular communication. Fura 2-loaded PANC-1 cells in serum-free medium were assayed for changes in cytosolic free calcium ([Ca]i) induced by depolarization, tolbutamide inhibition of K(ATP) channels, or glucose. Dye transfer, assayed by confocal microscopy or by FACS, was used to detect intercellular communication. Changes in messenger RNA (mRNA) expression of genes of interest were assessed by quantitative real-time polymerase chain reaction. Proliferation was assayed by the MTT method. Serum-deprived PANC-1 cell aggregates developed [Ca]i response to KCl, tolbutamide, or glucose. These responses were accompanied by 5-fold increase in glucokinase mRNA level and, to a lesser extent, of mRNAs for K(ATP) and L-type calcium channels, as well as increase in mRNA levels of glucagon and somatostatin. Trypsin, a proteinase-activated receptor 2 agonist previously shown to enhance aggregation, modestly improved [Ca]i response to glucose. Glucose-induced coordinated [Ca]i oscillations and dye transfer demonstrated the emergence of intercellular communication. These findings suggest that PANC-1 cells, a pancreatic adenocarcinoma cell line, can be induced to express a differentiated phenotype in which cells exhibit response to glucose and form a functional syncytium similar to those observed in pancreatic islets.

  6. Changes in glucose-elicited blood metabolite responses following weight loss and long term weight maintenance in obese individuals with impaired glucose tolerance.

    Science.gov (United States)

    Geidenstam, Nina; Danielsson, Anders P H; Spégel, Peter; Ridderstråle, Martin

    2016-03-01

    Weight loss improves insulin sensitivity and glucose tolerance in obese subjects with impaired glucose tolerance (IGT), but the long term dynamic effects on blood metabolites other than glucose during an oral glucose tolerance test (OGTT), are largely unknown. Here, we studied changes in OGTT-elicited metabolite patterns in obese subjects during a diet-induced weight loss study. Blood samples from 14 obese individuals with IGT were collected at 0, 30 and 120 min during a standard 75 g OGTT at baseline (BMI 44 ± 2 kg/m(2)), after weight loss (BMI 36 ± 2 kg/m(2)) and after weight maintenance (BMI 35 ± 2 kg/m(2)). Serum metabolite levels were analyzed by gas chromatography/mass spectrometry and compared to a lean glucose tolerant group. Changes in the OGTT-elicited metabolite patterns occurred differentially during weight loss and weight maintenance. Enhanced suppression of aromatic amino acids were associated with decreased insulinogenic index observed after weight loss (tyrosine: r=0.72, p=0.013; phenylalanine: r=0.63, p=0.039). The OGTT-elicited suppression and/or lack of increase in levels of glutamate, glutamine, isoleucine, leucine, and the fatty acids laurate, oleate and palmitate, improved towards the lean profile after weight maintenance, paralleling an improvement in glucose tolerance. The greater heterogeneity in the response before and after weight loss in the obese, compared to lean subjects, was markedly reduced after weight maintenance. Diet-induced weight loss followed by weight maintenance results in changes in metabolite profiles associated with either hepatic insulin sensitivity or peripheral glucose tolerance. Our results highlight the importance of evaluating the effects of weight loss and weight maintenance separately. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Effects of blood collection conditions on ovarian cancer serum markers.

    Directory of Open Access Journals (Sweden)

    Jason D Thorpe

    2007-12-01

    Full Text Available Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies.We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer.Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.

  8. Measurement of hydroxylated PCB metabolites for Slovakia maternal blood serums

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S.; Athanasiadou, M; Bergman, A. [Stockholm Univ., Stockholm (Sweden); Charles, J.; Zhao, G.; Hertz-Picciotto, I. [California Univ., Sacramento, CA (United States); Petrik, J.; Kocan, A; Trnovec, T. [Bratislava Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    2005-07-01

    Although it is known that polychlorinated biphenyls (PCBs) have adverse impacts on human health, it is not clear if human health impacts are caused by the PCBs or their related hydroxylated (OH) PCB metabolite compounds. This study measured OH-PCB metabolites in the maternal blood serum specimens from the Svidnik and Michalovce areas in eastern Slovakia where PCBs were intensively produced and inadequately disposed. The aim of the study was to characterize and quantify levels of specific OH-PCB metabolites in Slovakian maternal serums exposed to high environmental PCB levels. All specimens were analyzed for PCBs, and a subset of the samples was analyzed for OH-PCB metabolites. The Wallenburg blood extraction method was adopted to separate the OH-PCBs from the blood serums. Final eluates and calibration standards were spiked with PCB209 as an injection standard before gas chromatography (GC) analysis. OH-PCBs in the samples range from 75{+-}9 per cent to 101{+-}11 per cent. Median concentrations of OH-PCB metabolites of Michalovce samples were approximately twice as high as for the Svidnik samples. Concentrations of OH-PCBs of Michalovce blood samples were comparable to samples obtained from northern Canadian female Inuit and Faroe Island females, and were considered to be among the highest OH-PCB concentrations obtained in human blood. It was concluded that further research is needed to understand the placental transfer of OH-PCBs to the fetus, as well as epidemiological approaches to determine the relationship between the exposure of OH-PCB metabolites and child development. 12 refs., 2 figs.

  9. String Bean Juice Decreases Blood Glucose Level Patients with Diabetes Mellitus

    OpenAIRE

    Harmayetty, Harmayetty; Krisnana, Ilya; Anisa, Faida

    2009-01-01

    Introduction: Type 2 diabetes mellitus is deficiency of insulin and caused by decreases of insulin receptor or bad quality of insulin. As a result, insulin hormone does not work effectively in blood glucose regulation. String bean juice contains thiamin and fiber may regulate blood glucose level. The aim of this study was to analyze the effect of string bean juice to decrease blood glucose level of patients with type 2 diabetes mellitus. Method: This study employed a quasy-experimental pre-po...

  10. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting.

    Science.gov (United States)

    Klaff, Leslie J; Brazg, Ronald; Hughes, Kristen; Tideman, Ann M; Schachner, Holly C; Stenger, Patricia; Pardo, Scott; Dunne, Nancy; Parkes, Joan Lee

    2015-01-01

    This study evaluated the accuracy of Contour(®) Next (CN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ) compared with five blood glucose monitoring systems (BGMSs) across a wide range of clinically occurring blood glucose levels. Subjects (n=146) were ≥ 18 years and had type 1 or type 2 diabetes. Subjects' glucose levels were safely lowered or raised to provide a wide range of glucose values. Capillary blood samples were tested on six BGMSs and a YSI glucose analyzer (YSI Life Sciences, Inc., Yellow Springs, OH) as the reference. Extreme glucose values were achieved by glucose modification of the blood sample. System accuracy was assessed by mean absolute difference (MAD) and mean absolute relative difference (MARD) across several glucose ranges, with glucose range (Abbott Diabetes Care, Inc., Alameda, CA), 2.77 mg/dL; OneTouch(®) Ultra(®) 2 (LifeScan, Inc., Milpitas, CA), 10.20 mg/dL; OneTouch(®) Verio(®) Pro (LifeScan, Inc.), 4.53 mg/dL; and Truetrack(®) (Nipro Diagnostics, Inc., Fort Lauderdale, FL), 11.08 mg/dL. The lowest MAD in the low glucose range, from CN, was statistically significantly lower than those of the other BGMSs with the exception of the FSL. CN also had a statistically significantly lower MARD than all other BGMSs in the low glucose range. In the overall glucose range (21-496 mg/dL), CN yielded the lowest MAD and MARD values, which were statistically significantly lower in comparison with the other BGMSs. When compared with other BGMSs, CN demonstrated the lowest mean deviation from the reference value (by MAD and MARD) across multiple glucose ranges.

  11. Effect of cholera toxin administered supraspinally or spinally on the blood glucose level in pain and d-glucose fed animal models.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kang, Yu-Jung; Kim, Sung-Su; Kim, Chea-Ha; Kim, Su-Jin; Jung, Jun-Sub; Ryu, Ohk-Hyun; Choi, Moon-Gi; Choi, Seong-Soo; Suh, Hong-Won

    2013-04-01

    In the present study, the effect of intrathecal (i.t.) or intracerebroventricular (i.c.v.) administration with cholera toxin (CTX) on the blood glucose level was examined in ICR mice. The i.t. treatment with CTX alone for 24 h dose-dependently increased the blood glucose level. However, i.c.v. treatment with CTX for 24 h did not affect the blood glucose level. When mice were orally fed with D-glucose (2 g/kg), the blood glucose level reached to a maximum level at 30 min and almost returned to the control level at 120 min after D-glucose feeding. I.c.v. pretreatment with CTX increased the blood glucose level in a potentiative manner, whereas i.t. pretreatment with CTX increased the blood glucose level in an additive manner in a D-glucose fed group. In addition, the blood glucose level was increased in formalin-induced pain animal model. I.c.v. pretreatment with CTX enhanced the blood glucose level in a potentiative manner in formalin-induced pain animal model. On the other hand, i.t. pretreatment with CTX increased the blood glucose level in an additive manner in formalin-induced pain animal model. Our results suggest that CTX administered supraspinally or spinally differentially modulates the regulation of the blood glucose level in D-glucose fed model as well as in formalin-induced pain model.

  12. Glucose monitoring technologies - complementary or competitive? Role of continuous glucose monitoring versus flash glucose monitoring versus self-monitoring of blood glucose

    Directory of Open Access Journals (Sweden)

    Jothydev Kesavadev

    2017-01-01

    Full Text Available We have numerous technologies that can help keep a close watch on an individual's glycaemic status and thereby assist in developing successful diabetes management strategies. For more than five decades, self-monitoring of blood glucose (SMBG has remained as the gold standard tool to manage glycaemic status and has gained huge acceptance. Rigorous research further led to the development of more and more advanced technologies such as continuous glucose monitoring and flash glucose monitoring. These novel technologies are more promising in terms of revealing the complete glycaemic picture and even more user-friendly than the already established blood glucosemetres. However, they are yet to achieve remarkable accuracy and performance. There will also be a subgroup of patients who will be using these technologies only occasionally and thus will definitely require SMBG at other times. Again, with regard to the retrospective ones, glucose data can be obtained only once they are downloaded to the system and hence, real-time values will still have to be procured with the help of an SMBG. In future when the accuracy and performance of these newer technologies become equal to that of glucometres, the glucometres might vanish. Until then, all these technologies will definitely go hand-in-hand and supplement each other than competing each other. All the related literature were retrieved from various databases including 'PubMed' and 'Cochrane Database of Systematic Reviews' using specific search terms that were relevant to the topics discussed this manuscript.

  13. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  14. An examination of the hexokinase method for serum glucose assay using external quality assessment data.

    Science.gov (United States)

    Westwood, A; Bullock, D G; Whitehead, T P

    1986-01-01

    Hexokinase methods for serum glucose assay appeared to give slightly but consistently higher inter-laboratory coefficients of variation than all methods combined in the UK External Quality Assessment Scheme; their performance over a two-year period was therefore compared with that for three groups of glucose oxidase methods. This assessment showed no intrinsic inferiority in the hexokinase method. The greater variation may be due to the more heterogeneous group of instruments, particularly discrete analysers, on which the method is used. The Beckman Glucose Analyzer and Astra group (using a glucose oxidase method) showed the least inter-laboratory variability but also the lowest mean value. No comment is offered on the absolute accuracy of any of the methods.

  15. Effect of Guava in Blood Glucose and Lipid Profile in Healthy Human Subjects: A Randomized Controlled Study

    Science.gov (United States)

    Rakavi, R; Mangaraj, Manaswini

    2016-01-01

    Introduction The fruit of Psidium guajava (P.guajava) is known to contain free sugars yet the fruit juice showed hypoglycaemic effect. Hypoglycaemic activity of guava leaves has been well documented but not for guava fruit. Aim So we aimed to evaluate the effect of ripe guava (with peel and without peel) fruit supplementation on blood glucose and lipid profile in healthy human subjects. Materials and Methods Randomized Controlled study undertaken in: 1) Baseline; 2) 6 weeks supplementation phase. Forty five healthy MBBS students were included and randomly enrolled into Group A, Group B and Group C. In Baseline phase: Fasting Plasma Glucose (FPG) and serum lipid profile was done in all 3 groups. Group A were supplemented with 400g of ripe guava with peel and group B without peel, for 6 weeks. Rest 15 treated as control i.e., Group C. Result Supplementation of ripe guava fruit with peel reduced BMI as well as blood pressure (pguava pulp supplementation was not significant. Serum Total cholesterol, Triglycerides and Low Density Lipoprotein Cholesterol (LDLc) levels decreased significantly (pguava pulp without peel may have a favourable effect on lipid levels and blood sugar as well. Conclusion Guava fruit without peel is more effective in lowering blood sugar as well as serum total cholesterol, triglycerides and LDLc. It increases HDLc levels also. PMID:27790420

  16. The Effects of Blood Glucose Levels on Cognitive Performance: A Review of the Literature

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel

    2007-01-01

    The purpose of this review paper is to discuss the research literature on the effects of blood glucose levels on executive and non-executive functions in humans. The review begins with a brief description of blood glucose, how it has been studied, previous syntheses of prior studies, and basic results regarding the role of blood glucose on cognitive functioning. The following sections describe work that investigated the effect of blood glucose on both non-executive and executive functions (e.g., sensory processing, psychomotor functioning, attention, vigilance, memory, language and communication, judgement and decision-making, and complex task performance). Within each section, summaries of the findings and challenges to the literature are included. Measurement conversions of blood glucose levels, blood glucose values, and associated symptoms are depicted. References to the types of tests used to investigate blood glucose and cognitive performance are provided. For more detailed descriptions of references within (and in addition to) this paper, an annotated bibliography is also provided. Several moderator variables including individual differences and contextual variables related to the effects of blood glucose levels on performance (e.g., age, gender, time of day, familiarity with the task and symptom awareness, expectancy effects, dose dependent effects, time dependent effects, task specific effects, rising and falling blood glucose levels, and speed and/or accuracy trade-offs) are addressed later in the paper. Some suggestions for future experimental methodologies are also made.

  17. Elevated 1-h post-challenge plasma glucose levels in subjects with normal glucose tolerance or impaired glucose tolerance are associated with whole blood viscosity.

    Science.gov (United States)

    Marini, Maria Adelaide; Fiorentino, Teresa Vanessa; Andreozzi, Francesco; Mannino, Gaia Chiara; Perticone, Maria; Sciacqua, Angela; Perticone, Francesco; Sesti, Giorgio

    2017-08-01

    It has been suggested that glucose levels ≥155 mg/dl at 1-h during an oral glucose tolerance test (OGTT) may predict development of type 2 diabetes and cardiovascular events among adults with normal glucose tolerance (NGT 1 h-high). Studies showed a link between increased blood viscosity and type 2 diabetes. However, whether blood viscosity is associated with dysglycemic conditions such as NGT 1 h-high, impaired glucose tolerance (IGT) or impaired fasting glucose (IFG) is unsettled. 1723 non-diabetic adults underwent biochemical evaluation and OGTT. A validated formula based on hematocrit and total plasma proteins was employed to estimate whole blood viscosity. Subjects were categorized into NGT with 1 h glucose h-low), NGT-1 h-high, IFG and/or IGT. Hematocrit and blood viscosity values appeared significantly higher in individuals with NGT 1 h-high, IFG and/or IGT as compared to NGT 1 h-low subjects. Blood viscosity was significantly correlated with age, waist circumference, blood pressure, HbA1c, fasting, 1- and 2-h post-challenge insulin levels, total cholesterol and low-density lipoprotein, triglycerides, fibrinogen, white blood cell, and inversely correlated with high-density lipoprotein and insulin sensitivity. Of the four glycemic parameters, 1-h post-challenge glucose showed the strongest correlation with blood viscosity (β = 0.158, P h post-challenge plasma glucose. They also suggest that a subgroup of NGT individuals with 1-h post-challenge plasma >155 mg/dl have increased blood viscosity comparable to that observed in subjects with IFG and/or IGT.

  18. An artificial pancreas provided a novel model of blood glucose level variability in beagles.

    Science.gov (United States)

    Munekage, Masaya; Yatabe, Tomoaki; Kitagawa, Hiroyuki; Takezaki, Yuka; Tamura, Takahiko; Namikawa, Tsutomu; Hanazaki, Kazuhiro

    2015-12-01

    Although the effects on prognosis of blood glucose level variability have gained increasing attention, it is unclear whether blood glucose level variability itself or the manifestation of pathological conditions that worsen prognosis. Then, previous reports have not been published on variability models of perioperative blood glucose levels. The aim of this study is to establish a novel variability model of blood glucose concentration using an artificial pancreas. We maintained six healthy, male beagles. After anesthesia induction, a 20-G venous catheter was inserted in the right femoral vein and an artificial pancreas (STG-22, Nikkiso Co. Ltd., Tokyo, Japan) was connected for continuous blood glucose monitoring and glucose management. After achieving muscle relaxation, total pancreatectomy was performed. After 1 h of stabilization, automatic blood glucose control was initiated using the artificial pancreas. Blood glucose level varied for 8 h, alternating between the target blood glucose values of 170 and 70 mg/dL. Eight hours later, the experiment was concluded. Total pancreatectomy was performed for 62 ± 13 min. Blood glucose swings were achieved 9.8 ± 2.3 times. The average blood glucose level was 128.1 ± 5.1 mg/dL with an SD of 44.6 ± 3.9 mg/dL. The potassium levels after stabilization and at the end of the experiment were 3.5 ± 0.3 and 3.1 ± 0.5 mmol/L, respectively. In conclusion, the results of the present study demonstrated that an artificial pancreas contributed to the establishment of a novel variability model of blood glucose levels in beagles.

  19. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  20. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  1. Short-Term High-Intensity Interval Training on Body Composition and Blood Glucose in Overweight and Obese Young Women

    Directory of Open Access Journals (Sweden)

    Zhaowei Kong

    2016-01-01

    Full Text Available This study was to determine the effects of five-week high-intensity interval training (HIIT on cardiorespiratory fitness, body composition, blood glucose, and relevant systemic hormones when compared to moderate-intensity continuous training (MICT in overweight and obese young women. Methods. Eighteen subjects completed 20 sessions of HIIT or MICT for five weeks. HIIT involved 60 × 8 s cycling at ~90% of peak oxygen consumption (V˙O2peak interspersed with 12 s recovery, whereas MICT involved 40-minute continuous cycling at 65% of V˙O2peak. V˙O2peak, body composition, blood glucose, and fasting serum hormones, including leptin, growth hormone, testosterone, cortisol, and fibroblast growth factor 21, were measured before and after training. Results. Both exercise groups achieved significant improvements in V˙O2peak (+7.9% in HIIT versus +11.7% in MICT and peak power output (+13.8% in HIIT versus +21.9% in MICT despite no training effects on body composition or the relevant systemic hormones. Blood glucose tended to be decreased after the intervention (p=0.062. The rating of perceived exertion in MICT was higher than that in HIIT (p=0.042. Conclusion. Compared with MICT, short-term HIIT is more time-efficient and is perceived as being easier for improving cardiorespiratory fitness and fasting blood glucose for overweight and obese young women.

  2. Short-Term High-Intensity Interval Training on Body Composition and Blood Glucose in Overweight and Obese Young Women.

    Science.gov (United States)

    Kong, Zhaowei; Sun, Shengyan; Liu, Min; Shi, Qingde

    2016-01-01

    This study was to determine the effects of five-week high-intensity interval training (HIIT) on cardiorespiratory fitness, body composition, blood glucose, and relevant systemic hormones when compared to moderate-intensity continuous training (MICT) in overweight and obese young women. Methods . Eighteen subjects completed 20 sessions of HIIT or MICT for five weeks. HIIT involved 60 × 8 s cycling at ~90% of peak oxygen consumption ([Formula: see text]) interspersed with 12 s recovery, whereas MICT involved 40-minute continuous cycling at 65% of [Formula: see text]. [Formula: see text], body composition, blood glucose, and fasting serum hormones, including leptin, growth hormone, testosterone, cortisol, and fibroblast growth factor 21, were measured before and after training. Results . Both exercise groups achieved significant improvements in [Formula: see text] (+7.9% in HIIT versus +11.7% in MICT) and peak power output (+13.8% in HIIT versus +21.9% in MICT) despite no training effects on body composition or the relevant systemic hormones. Blood glucose tended to be decreased after the intervention ( p = 0.062). The rating of perceived exertion in MICT was higher than that in HIIT ( p = 0.042). Conclusion . Compared with MICT, short-term HIIT is more time-efficient and is perceived as being easier for improving cardiorespiratory fitness and fasting blood glucose for overweight and obese young women.

  3. [Influence of an infusion of 5- or 20% glucose solution on blood glucose and inorganic phosphate concentrations in dairy cows].

    Science.gov (United States)

    Aldaek, T A A; Failing, K; Wehrend, A; Klymiuk, M C

    2011-01-01

    The study was performed to evaluate the influence of an intravenous infusion of 5% and 20% dextrose solution on the plasma concentration of glucose and inorganic phosphate in healthy, dairy cows. Ten healthy, lactating, nonpregnant 3 to 6 year-old Holstein-Friesian cows were included in this investigation. The daily milk yield was 20.3±2.7 liters. Blood plasma concentrations of inorganic phosphate and glucose were determined before, during, immediately and 60 minutes after infusion of 0.9% physiological saline, 5% or 20% dextrose solution. A statistically significant influence of dextrose infusion on blood glucose concentration was observed. After 20% dextrose infusion (200 g dextrose) the blood glucose concentration increased by approximately 13.26 mmol/l. The administration of 5% dextrose solution (50 g dextrose) yielded an increase of blood glucose concentration by 3.31 mmol/l. There was no significant correlation between plasma inorganic phosphate concentrations and infusion of 0.9% saline, 5% or 20% dextrose solution. Intravenous administration of 1000 ml of 5% or 20% dextrose solution does not induce a lasting plasma phosphate reduction and is suitable for elevating the blood glucose concentration.

  4. Blood Glucose Levels Following Intra-Articular Steroid Injections in Patients with Diabetes: A Systematic Review.

    Science.gov (United States)

    Choudhry, M N; Malik, R A; Charalambous, Charalambos Panayiotou

    2016-03-22

    Parenterally administered steroids have been shown to affect the metabolism of glucose and to cause abnormal blood glucose levels in diabetic patients. These abnormal blood glucose levels in diabetic patients raise concerns that intra-articular steroid injections also may affect blood glucose levels. We performed a systematic review of studies examining the effect of intra-articular steroid injections on blood glucose levels in patients with diabetes mellitus. A literature search of the PubMed, EMBASE, AMED, and CINAHL databases using all relevant keywords and phrases revealed 532 manuscripts. After the application of inclusion criteria, seven studies with a total of seventy-two patients were analyzed. All studies showed a rise in blood glucose levels following intra-articular steroid injection. Four of the seven studies showed a substantial increase in blood glucose. Peak values reached as high as 500 mg/dL. The peak increase in blood glucose did not occur immediately following intra-articular steroid injection, and in some cases it took several days to occur. In many patients, post-injection hyperglycemia occurred within twenty-four to seventy-two hours. Intra-articular steroid injections may cause hyperglycemia in patients with diabetes mellitus, and patients should be warned of this complication. Diabetic patients should be advised to regularly monitor their blood glucose levels for up to a week after injection and should seek medical advice if safe thresholds are breached. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  5. Institutional blood glucose monitoring system for hospitalized patients: an integral component of the inpatient glucose control program.

    Science.gov (United States)

    Boaz, Mona; Landau, Zohar; Matas, Zipora; Wainstein, Julio

    2009-09-01

    The ability to measure patient blood glucose levels at bedside in hospitalized patients and to transmit those values to a central database enables and facilitates glucose control and follow-up and is an integral component in the care of the hospitalized diabetic patient. The goal of this study was to evaluate the performance of an institutional glucometer employed in the framework of the Program for the Treatment of the Hospitalized Diabetic Patient (PTHDP) at E. Wolfson Medical Center, Holon, Israel. As part of the program to facilitate glucose control in hospitalized diabetic patients, an institutional glucometer was employed that permits uploading of data from stands located in each inpatient department and downloading of that data to a central hospital-wide database. Blood glucose values from hospitalized diabetic patients were collected from August 2007 to October 2008. The inpatient glucose control program was introduced gradually beginning January 2008. During the follow-up period, more than 150,000 blood glucose measures were taken. Mean glucose was 195.7 +/- 99.12 mg/dl during the follow-up period. Blood glucose values declined from 206 +/- 105 prior to PTHDP (August 2007-December 2007) to 186 +/- 92 after its inception (January 2008-October 2008). The decline was associated significantly with time (r = 0.11, p < 0.0001). The prevalence of blood glucose values lower than 60 mg/dl was 1.48% [95% confidence interval (CI) 0.36%] prior to vs 1.55% (95% CI 0.37%) following implementation of the PTHDP. Concomitantly, a significant increase in the proportion of blood glucose values between 80 and 200 mg/dl was observed, from 55.5% prior to program initiation vs 61.6% after program initiation (p < 0.0001). The present study was designed to observe changes in institution-wide glucose values following implementation of the PTHDP. Information was extracted from the glucometer system itself. Because the aforementioned study was not a clinical trial, we cannot rule out

  6. Dietary thylakoids suppress blood glucose and modulate appetite-regulating hormones in pigs exposed to oral glucose tolerance test

    DEFF Research Database (Denmark)

    Montelius, Caroline; Szwiec, Katarzyna; Kardas, Marek

    2014-01-01

    BACKGROUND & AIMS: Dietary chloroplast thylakoids have previously been found to reduce food intake and body weight in animal models, and to change metabolic profiles in humans in mixed-food meal studies. The aim of this study was to investigate the modulatory effects of thylakoids on glucose...... metabolism and appetite-regulating hormones during an oral glucose tolerance test in pigs fed a high fat diet. METHODS: Six pigs were fed a high fat diet (36 energy% fat) for one month before oral glucose tolerance test (1 g/kg d-glucose) was performed. The experiment was designed as a cross-over study......, either with or without addition of 0.5 g/kg body weight of thylakoid powder. RESULTS: The supplementation of thylakoids to the oral glucose tolerance test resulted in decreased blood glucose concentrations during the first hour, increased plasma cholecystokinin concentrations during the first two hours...

  7. Ameliorative properties of ethyl acetate fraction of Ceiba pentandra on serum glucose, hematological and biochemical parameters of diabetic rats

    Directory of Open Access Journals (Sweden)

    Muhammad Hadiza Lami

    2015-09-01

    Full Text Available Objective: To evaluate the antidiabetic potential of Ceiba pentandra leaves used by some Nupe speaking community of Niger State, Nigeria in folkloric management of diabetes. Methods: Fifteen albino rats of both sexes weighing between 100 and 160 g were randomly allotted to five groups of four rats each. Alloxan monohydrate (110 mg/kg body weight was intraperitoneally administered to rats in their respective groups, and rats with blood glucose (200 mg/kg body weight were considered diabetic. Diabetic rats in their respective groups received 2.5 mg/kg body weight of standard drug (glibenclamide, 200 and 400 mg/kg body weight of extract once daily for 12 days. Normoglycemic group (reference group I received 0.5 mL normal saline, while the last group was untreated diabetic (reference group II. The blood glucose was measured by using Accu-Chek Active glucometer every three days and the experiment was terminated at 17th day. Results: Blood glucose decreased significantly (P < 0.05 in all the treated groups during the period of treatment with highest hypoglycaemic activity observed in 200 mg/kg body weight group. The diabetic untreated group showed significant reduction (P < 0.05 in body weight as it was a clinical feature of diabetes in reference to normoglycemic, and other treatment groups. Platelets showed a significant decrease and increase respectively in the untreated and treated groups in reference to the normoglycemic group. Decreased packed cell volume, red blood cells and hemoglobin count, and an increase in white blood cell were also observed in the untreated group. Body weight of the treated groups remained stable as against the reference group II. Activities of the serum alanine aminotransferase, aspartate aminotransferase, chloride and potassium increased significantly (P < 0.05 in standard drug while carbonate and sodium showed the opposite. The urea, creatinine, total and conjugated bilirubin all increased significantly (P < 0.05 in the

  8. Effect of intrapleural oxytocin injection on blood glucose level in rat (rattus norvegicous).

    Science.gov (United States)

    Dezhkam, Y; Dezhkam, N

    2014-01-01

    The effect of Oxytocin on energy metabolism is still question. The aim of the present study was to investigate the effect of exogenous oxytocin injection in different dose and timetable on blood glucose level in rat. In this study 16 adult female rats were divided into 2 groups (Treatment 1(T1) and Treatment 2(T2)). T1 with 8 adult female rats received 0.2 IU/Kg oxytocin via intrapleural (IP) and blood glucose level was tested at 0th, 20th, 40th and 60th min after injection by collecting the blood from jugular vein. In T2 eight female rats received 0.4 IU/kg oxytocin via IP taking blood glucose measure at the same minutes as T1. The experiment tested in three replicates. Blood glucose meter (Model: 3TMSO1G) was used with glucose smart blood glucose monitoring system to the measurement of blood glucose level in rats. Data were analyzed using the GLM procedure of SAS (SAS, version 9) PDIFF was used to compare least square means among treatments adjusting by tukey test. There were hypoglycemic tendency in the changes of the blood glucose level in both T1 and T2, 20th min after injection (88.79 ± 3.28, 68.58 ± 3.63, respectively), while in the remaining subjects (4th and 60th min) blood glucose level increased (115.54 ± 4, 79.7 ± 2.09 and 136.33 ± 5.8, 123.54 ± 0.9, respectively). These results showed that blood glucose level in T1 significantly higher than T2 (p blood glucose level very fast.

  9. Evaluation of blood glucose and thyroid function in Sudanese diabetic patients

    International Nuclear Information System (INIS)

    Agarib, M.O.A.

    2008-03-01

    This study composes of two parts. The first one is a survey of thyroid abnormalities, and the second one is experiment to estimate the level of thyroid hormones (T 4 , T 3 , TSH) among diabetic population and the relationship between the level of glucose, thyroid hormones and lipid profile (TC, LDL, TG, HDL) and comparison of the results with non diabetic group. The survey part of the study to determine the thyroid abnormalities, hypothyroidism or hyperthyroidism clinical or subclinical. Also the study group was divided in to two groups according to insulin requirement. Type I is insulin-dependent diabetes mellitus and type II is non insulin-dependent diabetes mellitus. The study subjects selected for this study consist of one hundred Sudanese diabetic patients, they had mean age of 46.51±10.672 years, a mean height of 162.06±10.77 cm and a mean weight of 73.47±14.91 kg. Fifty healthy non-diabetic people without endocrine disease were chosen as controls. Glucose, and thyroid hormones, thyroxine and triiodothyronine (total T 4 and T 3 ) and thyroid stimulating hormone (TSH) were measured. In addition hemoglobin (Hb), total cholesterol (TC), triglyceride (TG), high-density lipoproteins (HDL) were also measured in both groups. Low-density lipoprotein (LDL) was calculated for each sample. Physical examinations such as height, weight, and history of diabetes, family history, treatment were recorded in both groups. Determination of serum hormones concentration was carried out using highly sensitive RIA technique. While determination of blood glucose, hemoglobin, and lipid profile was carried out using enzymatic colorimetric method. The results of this study showed that: 13 patients of the population screened had thyroid disease. The commonest diagnosis was sub clinical hyperthyroidism (6%), followed by sub clinical hypothyroidism (5%) and hyperthyroidism (2%). Female patients with diabetes had the highest annual risk of developing thyroid disease but all patient

  10. Evaluation of blood glucose and thyroid function in Sudanese diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Agarib, M O.A. [Department of Biochemistry, Atomic Energy Council, Sudan Academy of Sciences, Khartoum (Sudan)

    2008-03-15

    This study composes of two parts. The first one is a survey of thyroid abnormalities, and the second one is experiment to estimate the level of thyroid hormones (T{sub 4}, T{sub 3}, TSH) among diabetic population and the relationship between the level of glucose, thyroid hormones and lipid profile (TC, LDL, TG, HDL) and comparison of the results with non diabetic group. The survey part of the study to determine the thyroid abnormalities, hypothyroidism or hyperthyroidism clinical or subclinical. Also the study group was divided in to two groups according to insulin requirement. Type I is insulin-dependent diabetes mellitus and type II is non insulin-dependent diabetes mellitus. The study subjects selected for this study consist of one hundred Sudanese diabetic patients, they had mean age of 46.51{+-}10.672 years, a mean height of 162.06{+-}10.77 cm and a mean weight of 73.47{+-}14.91 kg. Fifty healthy non-diabetic people without endocrine disease were chosen as controls. Glucose, and thyroid hormones, thyroxine and triiodothyronine (total T{sub 4} and T{sub 3}) and thyroid stimulating hormone (TSH) were measured. In addition hemoglobin (Hb), total cholesterol (TC), triglyceride (TG), high-density lipoproteins (HDL) were also measured in both groups. Low-density lipoprotein (LDL) was calculated for each sample. Physical examinations such as height, weight, and history of diabetes, family history, treatment were recorded in both groups. Determination of serum hormones concentration was carried out using highly sensitive RIA technique. While determination of blood glucose, hemoglobin, and lipid profile was carried out using enzymatic colorimetric method. The results of this study showed that: 13 patients of the population screened had thyroid disease. The commonest diagnosis was sub clinical hyperthyroidism (6%), followed by sub clinical hypothyroidism (5%) and hyperthyroidism (2%). Female patients with diabetes had the highest annual risk of developing thyroid

  11. Radioimmunossay of hormones and metabolites in blood serum and plasma

    International Nuclear Information System (INIS)

    Khare, G.P.

    1978-01-01

    Hormones or metabolites which are capable of producing antibodies can be detected and precisely quantitated by this method. Antibodies, to various hormones or metabolites whose assay is desired, are adsorbed onto commercially available imitation or cultured pearls. These pearls coated with antibody are contacted with a buffered reaction mixture containing blood serum or plasma specimen and respective radioactive antigen. The entire reaction is allowed to proceed for a time sufficient to form antigen (radioactive or non-radioactive)-antibody complex. These complexes on the pearls are washed and the total amount of radioactivity emanating from the complex is measured. This is indicative of the extent of binding of radioactive antigen and provides an indirect correlation of the amount of non-radioactive antigen present in the serum or plasma sample

  12. Glucagon-like peptide-1 inhibits blood-brain glucose transfer in humans

    DEFF Research Database (Denmark)

    Lerche, Susanne; Brock, Birgitte; Rungby, Jørgen

    2008-01-01

    OBJECTIVE: Glucagon-like peptide-1 (GLP-1) has many effects on glucose homeostasis, and GLP-1 receptors are broadly represented in many tissues including the brain. Recent research in rodents suggests a protective effect of GLP-1 on brain tissue. The mechanism is unknown. We therefore tested......-independent effect of GLP-1 on unidirectional glucose transport into the brain during a pituitary-pancreatic normoglycemic (plasma glucose approximately 4.5 mmol/l) clamp with 18-fluoro-deoxy-glucose as tracer. RESULTS: On average, GLP-1 reduced cerebral glucose transport by 27% in total cerebral gray matter (P = 0...... that a hormone involved in postprandial glucose regulation also limits glucose delivery to brain tissue and hence provides a possible regulatory mechanism for the link between plasma glucose and brain glucose. Because GLP-1 reduces glucose uptake across the intact blood-brain barrier at normal glycemia, GLP-1...

  13. Relationship between local cerebral glucose uptakes, serum prolactin, growth hormone and cortisol levels changes during epilepsy

    International Nuclear Information System (INIS)

    Wang Mingfang; Mao Xianghui; Tang Ganghua; Zhao Jun; Sun Aijun

    2002-01-01

    Objective: To explore the relation of local cerebral FDG uptake value of glucose to the changes of prolactin (PRL), growth hormone (GH) and cortisol levels in serum during epilepsy. Methods: 76 epileptic patients with solitary epileptic focus were examined by 2-deoxy-2-[ 18 F] fluoro-D-glucose ( 18 F-FDG) positron emission tomography (PET) imaging and the FDG uptake value of epileptic foci were measured. Serum PRL, GH and cortisol levels of the patients were determined by radioimmunoassay (RIA) before and after seizures. Results: During ictal studies, all patients showed increased FDG uptake of epileptic foci compared with that in interictal phase. The serum PRL, GH and cortisol levels were significant higher after seizures. The changes of hormone levels correlated significantly with the lengths of seizure free intervals (SFIs) and with the types of seizures. But the variations of hormone levels had no relation with the site and FDG uptake of epileptic foci. In patients with absentia seizures, no significant increase was observed in serum PRL and cortisol levels. The changes of GH were not related with the types of seizures. Also, it was found that changes of hormone levels had significant relations to the lengths of SFIs. Conclusions: Serum PRL, GH and cortisol levels were significantly different before and after seizures. This study suggests that changes of postictal hormone levels correlated significantly with the types of seizures and lengths of SFIs, but the changes of hormone levels are not related with the site and FDG uptake of epileptic foci

  14. Analysis of blood glucose distribution characteristics in a health examination population in Chengdu (2007-2015).

    Science.gov (United States)

    Huang, Wenxia; Xu, Wangdong; Zhu, Ping; Yang, Hanwei; Su, Linchong; Tang, Huairong; Liu, Yi

    2017-12-01

    With socioeconomic growth and cultural changes in China, the level of blood glucose may have changed in recent years. This study aims to detect the blood glucose distribution characteristics with a large size of health examination population.A total of 641,311 cases (360,259 males and 281,052 females) more than 18 years old during 2007 to 2015 were recruited from the Health Examination Center at West China hospital, Sichuan University.The percentage of cases with abnormal glucose level and the mean level of glucose were significantly increased since 2007 to 2015 overall. The percentage of cases with abnormal glucose level in males was significantly higher than that in females every year, and the percentage of cases with abnormal glucose level in aged population was higher than the young population. In addition, the mean level of glucose was higher in aged population with normal level of glucose than the young population with normal level of glucose, and the mean level of glucose was higher in males with normal level of glucose than the females with normal level of glucose.The population showed an increased level of blood glucose. Some preventive action may be adopted early and more attention can be paid to them.

  15. Effects of intravenous glucose infusion and nutritional balance on serum concentrations of nonesterified fatty acids, glucose, insulin, and progesterone in nonlactating dairy cows.

    Science.gov (United States)

    Vieira, F V R; Lopes, C N; Cappellozza, B I; Scarpa, A B; Cooke, R F; Vasconcelos, J L M

    2010-07-01

    The objective of this study was to evaluate serum concentrations of nonesterified fatty acids, glucose, insulin, and progesterone in nonlactating dairy cows according to nutritional balance and glucose infusion. Ten nonlactating, ovariectomized Gir x Holstein cows were stratified by body weight (BW) and body condition score (BCS) on d -28 of the study, and randomly assigned to 1) negative nutrient balance (NB) or 2) positive nutrient balance (PB). From d -28 to d 0, cows were allocated according to nutritional treatment (5 cows/treatment) into 2 low-quality pastures with reduced forage availability. However, PB cows individually received, on average, 3 kg/cow per day (as-fed) of a concentrate during the study. All cows had an intravaginal progesterone releasing device inserted on d -14, which remained in cows until the end of the study. Cow BW and BCS were assessed again on d 0. On d 0, cows within nutritional treatment were randomly assigned to receive, in a crossover design containing 2 periods of 24h each, 1) intravenous glucose infusion (GLU; 0.5 g of glucose/kg of BW, as a 5% glucose solution administered, on average, at 32 mL/min over a 3-h period), or 2) intravenous saline infusion (SAL; 0.9% solution infused on average at 32 mL/min over a 3-h period). Prior to the beginning of each period, all cows were fasted for 12h. Blood samples were collected, relative to the beginning of the infusion, at -12 and -11.5h (beginning of fasting), and at -0.5, 0, 0.5, 1, 2, 3, 4, 5, and 6h. Following the last blood collection of period 1, cows received (PB) or not (NB) concentrate and were returned to their respective pastures. Changes in BCS and BW were greater in NB cows compared with PB cows (-0.60 and -0.25+/-0.090 for BCS, respectively; -22.4 and 1.2+/-6.58 kg for BW, respectively). Cows receiving GLUC had greater glucose concentrations from 0.5 to 3h relative to infusion compared with SAL cows. Insulin concentrations were greater in PB cows assigned to GLUC compared

  16. Parsimonious model for blood glucose level monitoring in type 2 diabetes patients.

    Science.gov (United States)

    Zhao, Fang; Ma, Yan Fen; Wen, Jing Xiao; DU, Yan Fang; Li, Chun Lin; Li, Guang Wei

    2014-07-01

    To establish the parsimonious model for blood glucose monitoring in patients with type 2 diabetes receiving oral hypoglycemic agent treatment. One hundred and fifty-nine adult Chinese type 2 diabetes patients were randomized to receive rapid-acting or sustained-release gliclazide therapy for 12 weeks. Their blood glucose levels were measured at 10 time points in a 24 h period before and after treatment, and the 24 h mean blood glucose levels were measured. Contribution of blood glucose levels to the mean blood glucose level and HbA1c was assessed by multiple regression analysis. The correlation coefficients of blood glucose level measured at 10 time points to the daily MBG were 0.58-0.74 and 0.59-0.79, respectively, before and after treatment (Pblood glucose levels measured at 6 of the 10 time points could explain 95% and 97% of the changes in MBG before and after treatment. The three blood glucose levels, which were measured at fasting, 2 h after breakfast and before dinner, of the 10 time points could explain 84% and 86% of the changes in MBG before and after treatment, but could only explain 36% and 26% of the changes in HbA1c before and after treatment, and they had a poorer correlation with the HbA1c than with the 24 h MBG. The blood glucose levels measured at fasting, 2 h after breakfast and before dinner truly reflected the change 24 h blood glucose level, suggesting that they are appropriate for the self-monitoring of blood glucose levels in diabetes patients receiving oral anti-diabetes therapy. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  17. Glucose-induced serum- and glucocorticoid-regulated kinase activation in oncofetal fibronectin expression

    International Nuclear Information System (INIS)

    Khan, Zia A.; Barbin, Yousef P.; Farhangkhoee, Hana; Beier, Norbert; Scholz, Wolfgang; Chakrabarti, Subrata

    2005-01-01

    Preferential expression of oncofetal extra domain-B fibronectin (EDB + FN), a proposed angiogenic marker, has been shown in proliferative diabetic retinopathy. High levels of glucose also increase EDB + FN expression in endothelial cells (ECs) via transforming growth factor-β1 (TGF-β1) and endothelin-1 (ET-1). The present study was aimed at elucidating the role of serum- and glucocorticoid-regulated kinase (SGK-1) in glucose-induced EDB + FN expression. Using human macro- and microvascular ECs, we show that high levels of glucose, TGF-β1, and ET-1 increase the EDB + FN expression via SGK-1 alteration at the mRNA, protein, and activity levels. Inhibition of TGF-β1 and ET-1 prevented glucose-induced SGK-1 activation and the EDB + FN expression. Furthermore, using siRNA-mediated SGK-1 gene silencing, we show that glucose-induced EDB + FN expression can be completely prevented. These findings provide first evidence of glucose-induced SGK-1 activation in altered EDB + FN expression and provide novel avenues for therapeutic modalities

  18. Serum progranulin concentrations are not responsive during oral lipid tolerance test and oral glucose tolerance test.

    Science.gov (United States)

    Schmid, A; Leszczak, S; Ober, I; Schäffler, A; Karrasch, T

    2015-07-01

    The postprandial regulation of progranulin by oral uptake of lipids and carbohydrates in healthy individuals has not yet been investigated. The regulation of progranulin in 2 large cohorts of healthy volunteers during oral lipid tolerance test (OLTT; n=100) and oral glucose tolerance test (OGTT; n=100) was analyzed. One hundred healthy volunteers underwent OLTT and OGTT in an outpatient setting. Venous blood was drawn at 0 hours (h) (fasting) and at 2, 4, and 6 h in OLTT or 1 and 2 h in OGTT. A novel OLTT solution completely free of carbohydrates and protein was applied. Subjects were characterized by anthropometric and laboratory parameters. Serum concentrations of progranulin were measured by enzyme-linked immunosorbent assay (ELISA). Circulating progranulin levels remained unchanged during OLTT and OGTT. Fasting progranulin levels ranged between 31.3±8.7 and 40.6±7.7 ng/ml and were not different in subgroups addressing BMI, gender, family history, smoking habits, and hormonal contraception. There was a reciprocal correlation of progranulin with HDL (negative) and LDL cholesterol levels (positive). In healthy adults, fasting and postprandial circulating progranulin levels are not different in BMI subgroups. Oral uptake of carbohydrates and lipids does not influence circulating progranulin levels in a short-term manner. A postprandial and short-term regulation of this adipokine is absent, at least in healthy subjects. There is a negative correlation of progranulin with HDL cholesterol, but a positive correlation with LDL cholesterol. This reciprocal association might be of physiological importance for an individual's atherosclerotic risk. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Blood Glucose Monitoring Before and After Type 1 Diabetes Clinic Visits.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Wright, Nancy; Deeb, Larry C

    2017-12-23

    To determine patterns of blood glucose monitoring in children and adolescents with type 1 diabetes (T1D) before and after routine T1D clinic visits. Blood glucose monitoring data were downloaded at four consecutive routine clinic visits from children and adolescents aged 5-18 years. Linear mixed models were used to analyze patterns of blood glucose monitoring in patients who had at least 28 days of data stored in their blood glucose monitors. In general, the frequency of blood glucose monitoring decreased across visits, and younger children engaged in more frequent blood glucose monitoring. Blood glucose monitoring increased before the T1D clinic visits in younger children, but not in adolescents. It declined after the visit regardless of age. Members of the T1D care team need to consider that a T1D clinic visit may prompt an increase in blood glucose monitoring when making treatment changes and recommendations. Tailored interventions are needed to maintain that higher level of adherence across time. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  20. Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.

    Science.gov (United States)

    McGrath, Rachel T; Donnelly, Vanessa C; Glastras, Sarah J; Preda, Veronica A; Sheriff, Nisa; Ward, Peter; Hocking, Samantha L; Fulcher, Gregory R

    2016-02-01

    The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; however, the accuracy of blood glucose meters in pregnancy is unclear. Pregnant women with gestational, type 1, or type 2 diabetes mellitus were eligible to participate. Nonfasting capillary blood glucose levels were measured in duplicate using the BGStar(®) (Sanofi, Sydney, Australia) and FreeStyle Lite(®) (Abbott, Sydney) blood glucose meters. Venous blood samples were collected and analyzed for plasma glucose, hematocrit, and glycated hemoglobin. Capillary blood glucose was compared with plasma glucose and further assessed according to International Organization for Standardization (ISO) 15197:2013 standards. One hundred ten women were recruited, providing 96 samples suitable for analysis. The mean ± SD laboratory plasma glucose level was 4.6 ± 1.4 mmol/L; the BGStar and FreeStyle Lite capillary blood glucose values were 5.3 ± 1.4 mmol/L and 5.0 ± 1.3 mmol/L, respectively. Both meters showed a positive bias (0.42 mmol/L for the FreeStyle Lite and 0.65 mmol/L for the BGStar). Furthermore, neither meter fulfilled the ISO 15197:2013 standards, and there was a nonsignificant improvement in meter performance at blood glucose levels of ≤4.2 mmol/L. Hematocrit did not affect the results of either blood glucose meter. Clarke Error Grid analysis demonstrated that approximately 70% of the results of both meters would lead to appropriate clinical action. The BGStar and FreeStyle Lite blood glucose meters did not meet ISO 15197:2013 recommendations for blood glucose monitoring systems when assessed in a population of women with diabetes in pregnancy. Clinicians should consider this difference in blood glucose readings when making diabetes

  1. Quantify Glucose Level in Freshly Diabetic's Blood by Terahertz Time-Domain Spectroscopy

    Science.gov (United States)

    Chen, Hua; Chen, Xiaofeng; Ma, Shihua; Wu, Xiumei; Yang, Wenxing; Zhang, Weifeng; Li, Xiao

    2018-04-01

    We demonstrate the capability of terahertz (THz) time-domain spectroscopy (TDS) to quantify glucose level in ex vivo freshly diabetic's blood. By investigating the THz spectra of different human blood, we find out THz absorption coefficients reflect a high sensitivity to the glucose level in blood. With a quantitative analysis of 70 patients, we demonstrate that the THz absorption coefficients and the blood glucose levels perform a linear relationship. A comparative experiment between THz measurement and glucometers is also conducted with another 20 blood samples, and the results confirm that the relative error is as less as 15%. Our ex vivo human blood study indicates that THz technique has great potential application to diagnose blood glucose level in clinical practice.

  2. Nanostructured gold deposited in gelatin template applied for electrochemical assay of glucose in serum

    Czech Academy of Sciences Publication Activity Database

    Juřík, T.; Podešva, Pavel; Farka, Z.; Kovář, D.; Skládal, P.; Foret, František

    2016-01-01

    Roč. 188, JAN (2016), s. 277-285 ISSN 0013-4686 R&D Projects: GA ČR(CZ) GA15-15479S Institutional support: RVO:68081715 Keywords : gold nanostructures * gelatin template * glucose electrooxidation * blood analysis * non-enzymatic sensor Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.798, year: 2016

  3. Are serum adiponectin concentrations in a population sample of 64-year-old Caucasian women with varying glucose tolerance associated with ultrasound-assessed atherosclerosis?

    Science.gov (United States)

    Behre, C J; Brohall, G; Hulthe, J; Wikstrand, J; Fagerberg, B

    2006-09-01

    To examine whether serum adiponectin concentrations were associated with subclinical atherosclerosis assessed as intima media thickness (IMT) in the carotid arteries in Caucasian women with varying degrees of glucose tolerance. From a population-based cohort of 64-year-old Swedish women, 533 subjects with type 2 diabetes (DM2, n=177), impaired glucose tolerance (IGT; n=178) or normal glucose tolerance (NGT, n=178) were recruited. Anthropometrics, usual cardiovascular risk factors were examined and ultrasound examination of the carotid arteries was performed. Women with low adiponectin concentrations were characterized by thick IMT, higher prevalence of DM2, history of previous myocardial infarction, angina pectoris, anti-hypertensive treatment and high body mass index (BMI), waist circumference, plasma insulin, serum triglycerides, fasting glucose, HbA1c, and low serum HDL cholesterol levels. Carotid IMT correlated with HbA1c (r=0.24, PDM2 (r=0.16, P<0.001), systolic blood pressure (r=0.16, P<0.001), blood glucose (r=0.16, P<0.001), triglycerides (r=0.15, P<0.001), and reversely to adiponectin (r=-0.11, P=0.01), HDL cholesterol (r=-0.13, P=0.004), and alcohol intake (r=-0.087, P<0.05). A more detailed analysis of underlying associations was difficult due to a high co-linearity between these variable. Low serum adiponectin concentrations were associated with increased carotid artery IMT, and several risk factors for cardiovascular diseases, mainly those constituting the metabolic syndrome.

  4. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring

    OpenAIRE

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-01-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery–powered electrochemical twin channels (ETCs). The ...

  5. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben

    2010-01-01

    using a biosensitive electrode (Exp. 1) or a standard colourimetric method (Exp. 2). In general, glucose measured in whole blood was 7-11% lower than in plasma at low glucose levels (3.5-5 mM), whereas the methods agreed well at high glucose levels (10-14 mM). Evaluation of the regression lines between......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  6. Effect of melatonin on serum glucose and body weights in streptozotocin induced diabetes in albino rats

    International Nuclear Information System (INIS)

    Hidayat, M.

    2015-01-01

    It has been demonstrated in experimental animal models that oxidative stress causes persistent and chronic hyperglycaemia, causing reduction in antioxidant defence system, ultimately leading to accumulation of free radicals.This study was performed to observe the effect of melatonin on serum glucose and body weights in streptozotocin induced diabetes in albino rats. Methods: Forty healthy adult male albino rats were included in the study and divided equally into 4 groups for 6 weeks. Group-A was taken as control. Group-B received streptozotocin I/P in a dose of 37 mg/kg body weight. Group-C received 10 mg/100 ml melatonin in drinking water and Group-D received only melatonin. Results: Streptozotocin significantly increased serum glucose and decreased weight in group B animals, whereas in group C, melatonin significantly restored serum glucose but could not restore the body weights reduced by streptozotocin. There was a significant reduction in body weight in melatonin treated group D animals. Conclusion: Melatonin decreases oxidative stress and hyperglycemia, but cannot restore the body weight reduced by streptozotocin. In fact, it further reduces body weight both in diabetic and normal state. (author)

  7. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob L.; Kurzban, Robert

    2016-01-01

    identified 42 studies relating to 4 dimensions of decision making: willingness to pay, willingness to work, time discounting, and decision style. We did not find a uniform influence of blood glucose on decision making. Instead, we found that low levels of blood glucose increase the willingness to pay...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money....... Low levels of blood glucose also increase the tendency to make more intuitive rather than deliberate decisions. However, this effect was only observed in situations unrelated to food. We conclude that blood glucose has domain-specific effects, influencing decision making differently depending...

  8. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  9. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  10. Is the formula of Traub still up to date in antemortem blood glucose level estimation?

    Science.gov (United States)

    Palmiere, Cristian; Sporkert, Frank; Vaucher, Paul; Werner, Dominique; Bardy, Daniel; Rey, François; Lardi, Christelle; Brunel, Christophe; Augsburger, Marc; Mangin, Patrice

    2012-05-01

    According to the hypothesis of Traub, also known as the 'formula of Traub', postmortem values of glucose and lactate found in the cerebrospinal fluid or vitreous humor are considered indicators of antemortem blood glucose levels. However, because the lactate concentration increases in the vitreous and cerebrospinal fluid after death, some authors postulated that using the sum value to estimate antemortem blood glucose levels could lead to an overestimation of the cases of glucose metabolic disorders with fatal outcomes, such as diabetic ketoacidosis. The aim of our study, performed on 470 consecutive forensic cases, was to ascertain the advantages of the sum value to estimate antemortem blood glucose concentrations and, consequently, to rule out fatal diabetic ketoacidosis as the cause of death. Other biochemical parameters, such as blood 3-beta-hydroxybutyrate, acetoacetate, acetone, glycated haemoglobin and urine glucose levels, were also determined. In addition, postmortem native CT scan, autopsy, histology, neuropathology and toxicology were performed to confirm diabetic ketoacidosis as the cause of death. According to our results, the sum value does not add any further information for the estimation of antemortem blood glucose concentration. The vitreous glucose concentration appears to be the most reliable marker to estimate antemortem hyperglycaemia and, along with the determination of other biochemical markers (such as blood acetone and 3-beta-hydroxybutyrate, urine glucose and glycated haemoglobin), to confirm diabetic ketoacidosis as the cause of death.

  11. Effect of whey on blood glucose and insulin responses to composite breakfast and lunch meals in type 2 diabetic subjects.

    Science.gov (United States)

    Frid, Anders H; Nilsson, Mikael; Holst, Jens Juul; Björck, Inger M E

    2005-07-01

    Whey proteins have insulinotropic effects and reduce the postprandial glycemia in healthy subjects. The mechanism is not known, but insulinogenic amino acids and the incretin hormones seem to be involved. The aim was to evaluate whether supplementation of meals with a high glycemic index (GI) with whey proteins may increase insulin secretion and improve blood glucose control in type 2 diabetic subjects. Fourteen diet-treated subjects with type 2 diabetes were served a high-GI breakfast (white bread) and subsequent high-GI lunch (mashed potatoes with meatballs). The breakfast and lunch meals were supplemented with whey on one day; whey was exchanged for lean ham and lactose on another day. Venous blood samples were drawn before and during 4 h after breakfast and 3 h after lunch for the measurement of blood glucose, serum insulin, glucose-dependent insulinotropic polypeptide (GIP), and glucagon-like peptide 1 (GLP-1). The insulin responses were higher after both breakfast (31%) and lunch (57%) when whey was included in the meal than when whey was not included. After lunch, the blood glucose response was significantly reduced [-21%; 120 min area under the curve (AUC)] after whey ingestion. Postprandial GIP responses were higher after whey ingestion, whereas no differences were found in GLP-1 between the reference and test meals. It can be concluded that the addition of whey to meals with rapidly digested and absorbed carbohydrates stimulates insulin release and reduces postprandial blood glucose excursion after a lunch meal consisting of mashed potatoes and meatballs in type 2 diabetic subjects.

  12. Salivary glucose levels and its correlation with serum glucose and glycemic status in Diabetics

    Directory of Open Access Journals (Sweden)

    Vagish Kumar L S

    2014-02-01

    Conclusion:-Saliva can be used as a routine potential diagnostic tool in assessing diabetes mellitus, the most prevalent among Indian population. It is a simple and non invasive technique in screening and monitoring of this disease. Repeated painful pricks, hazard of getting infections, complications in hemophiliac patients and various other disadvantages that involve the blood tests currently used for diagnosis and monitoring of this widely prevalent Diabetes mellitus disease, can be replaced by non invasive tests involving Saliva, which is also a cost effective.

  13. Tumor blood flow and pH changes after glucose administration

    International Nuclear Information System (INIS)

    Thistlethwaite, A.J.; Tupchong, L.; Leeper, D.B.

    1987-01-01

    The authors used a laser doppler technique to correlate blood flow changes with pH changes in human tumors after glucose ingestion. Three PTs with large superficial tumors ingested 100 gm glucose. A 21g needle pH electrode (Micro-electrodes, Inc.) and a 21g ''Laserflo'' fiberoptic laser doppler blood flow probe (TSI, Minneapolis, MN) were used at the same location. Blood glucose was measured by finger stick every 7.5 min. One PT with a squamous cell CA with extensive necrosis had only a small increase in blood glucose and an increase in tumor pH. Blood flow readings were within 6.4-18.4ml/100g/min. Another PT with a squamous CA had a drop in tumor pH (7.46 to 7.05) as blood glucose increased from 85 to 137 mg/dl by 55 min. Blood flow remained in a range of 7.7-13.8 ml/100g/min with a mean of 11.4. The third PT with a sarcoma had tumor pH and blood glucose measurements on two occasions, with similar results. Blood glucose rose from approx. 100 to 150 mg/dl by 52.5 min with a drop in tumor pH from approx. 7.4 to 7.25. On the second trial, tumor blood flow was measured and, while erratic (6.4-24.9ml/100g/min), decreased by approx. 50%. These preliminary data show that the laser doppler blood flow technique is quite sensitive to movement artifact and interference by free hemoglobin. Currently, it is inconclusive whether blood flow is altered with blood glucose and tumor pH changes. Further studies may prove this to be a valuable tool in predicting tumor response to hyperthermia

  14. Clinical results from a noninvasive blood glucose monitor

    Science.gov (United States)

    Blank, Thomas B.; Ruchti, Timothy L.; Lorenz, Alex D.; Monfre, Stephen L.; Makarewicz, M. R.; Mattu, Mutua; Hazen, Kevin

    2002-05-01

    Non-invasive blood glucose monitoring has long been proposed as a means for advancing the management of diabetes through increased measurement and control. The use of a near-infrared, NIR, spectroscopy based methodology for noninvasive monitoring has been pursued by a number of groups. The accuracy of the NIR measurement technology is limited by challenges related to the instrumentation, the heterogeneity and time-variant nature of skin tissue, and the complexity of the calibration methodology. In this work, we discuss results from a clinical study that targeted the evaluation of individual calibrations for each subject based on a series of controlled calibration visits. While the customization of the calibrations to individuals was intended to reduce model complexity, the extensive requirements for each individual set of calibration data were difficult to achieve and required several days of measurement. Through the careful selection of a small subset of data from all samples collected on the 138 study participants in a previous study, we have developed a methodology for applying a single standard calibration to multiple persons. The standard calibrations have been applied to a plurality of individuals and shown to be persistent over periods greater than 24 weeks.

  15. Positive sliding mode control for blood glucose regulation

    Science.gov (United States)

    Menani, Karima; Mohammadridha, Taghreed; Magdelaine, Nicolas; Abdelaziz, Mourad; Moog, Claude H.

    2017-11-01

    Biological systems involving positive variables as concentrations are some examples of so-called positive systems. This is the case of the glycemia-insulinemia system considered in this paper. To cope with these physical constraints, it is shown that a positive sliding mode control (SMC) can be designed for glycemia regulation. The largest positive invariant set (PIS) is obtained for the insulinemia subsystem in open and closed loop. The existence of a positive SMC for glycemia regulation is shown here for the first time. Necessary conditions to design the sliding surface and the discontinuity gain are derived to guarantee a positive SMC for the insulin dynamics. SMC is designed to be positive everywhere in the largest closed-loop PIS of plasma insulin system. Two-stage SMC is employed; the last stage SMC2 block uses the glycemia error to design the desired insulin trajectory. Then the plasma insulin state is forced to track the reference via SMC1. The resulting desired insulin trajectory is the required virtual control input of the glycemia system to eliminate blood glucose (BG) error. The positive control is tested in silico on type-1 diabetic patients model derived from real-life clinical data.

  16. Effect of Cholera Toxin Administered Supraspinally or Spinally on the Blood Glucose Level in Pain and D-Glucose Fed Animal Models

    OpenAIRE

    Sim, Yun-Beom; Park, Soo-Hyun; Kang, Yu-Jung; Kim, Sung-Su; Kim, Chea-Ha; Kim, Su-Jin; Jung, Jun-Sub; Ryu, Ohk-Hyun; Choi, Moon-Gi; Choi, Seong-Soo; Suh, Hong-Won

    2013-01-01

    In the present study, the effect of intrathecal (i.t.) or intracerebroventricular (i.c.v.) administration with cholera toxin (CTX) on the blood glucose level was examined in ICR mice. The i.t. treatment with CTX alone for 24 h dose-dependently increased the blood glucose level. However, i.c.v. treatment with CTX for 24 h did not affect the blood glucose level. When mice were orally fed with D-glucose (2 g/kg), the blood glucose level reached to a maximum level at 30 min and almost returned to...

  17. A liquid chromatographic method for determination of theophylline in serum and capillary blood--a comparison.

    Science.gov (United States)

    Gartzke, J; Jäger, H; Vins, I

    1991-01-01

    A simple, fast and reliable liquid chromatographic method for the determination of theophylline in serum and capillary blood after a solid phase extraction is described for therapeutic drug monitoring. The employment of capillary blood permits the determination of an individual drug profile and other pharmacokinetic studies in neonates and infants. There were no differences in venous- and capillary-blood levels but these values compared poorly with those in serum. An adjustment of the results by correction of the different volumes of serum and blood by haematocrit was unsuccessful. Differences in the binding of theophylline to erythrocytes could be an explanation for the differences in serum at blood levels of theophylline.

  18. Photoacoustic determination of glucose concentration in whole blood by a near-infrared laser diode

    Science.gov (United States)

    Zhao, Zuomin; Myllylae, Risto A.

    2001-06-01

    The near-infrared photoacoustic technique is recognized as a potential method for the non-invasive determination of human glucose, because near-infrared light can incident a few millimeters into human tissue, where it produces an acoustic wave capable of carrying information about the composition of the tissue. This paper demonstrates a photoacoustic glucose measurement in a blood sample as a step toward a non-invasive measurement. The experimental apparatus consists of a near-infrared laser diode operating with 4 micro joules pulse energy at 905 nm, a roller pump connected to a silicon plastic tube and a cuvette for circulating the blood sample. In addition, the apparatus comprises a PZT piezoelectric transducer integrated with a battery-powered preamplifier to receive the photoacoustic signal. During the experiment, a glucose solution is mixed into a human blood sample to change its concentration. Although the absorption coefficient of glucose is much smaller than that of blood in the near-infrared region, the osmotic and hydrophilic properties of glucose decrease the reduced scattering coefficient of blood caused by the dissolved glucose surrounding the blood cells. This changes the distribution of the absorbed optical energy in blood, which, in turn, produces a change in the photoacoustic signal. Our experiment demonstrates that signal amplitudes in fresh and stored blood samples in crease about 7% and 10%, respectively, when the glucose concentration reaches the upper limit of the physiological region (500 mg/dl).

  19. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Vahidi, O; Kwok, K E; Gopaluni, R B

    2016-01-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main...... variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data...... obtained during oral glucose tolerance test and isoglycemic intravenous glucose infusion test from both type 2 diabetic and healthy subjects to estimate the model parameters and to validate the model results. The estimation of model parameters is accomplished through solving a nonlinear optimization...

  20. [Predictors of mean blood glucose control and its variability in diabetic hospitalized patients].

    Science.gov (United States)

    Sáenz-Abad, Daniel; Gimeno-Orna, José Antonio; Sierra-Bergua, Beatriz; Pérez-Calvo, Juan Ignacio

    2015-01-01

    This study was intended to assess the effectiveness and predictors factors of inpatient blood glucose control in diabetic patients admitted to medical departments. A retrospective, analytical cohort study was conducted on patients discharged from internal medicine with a diagnosis related to diabetes. Variables collected included demographic characteristics, clinical data and laboratory parameters related to blood glucose control (HbA1c, basal plasma glucose, point-of-care capillary glucose). The cumulative probability of receiving scheduled insulin regimens was evaluated using Kaplan-Meier analysis. Multivariate regression models were used to select predictors of mean inpatient glucose (MHG) and glucose variability (standard deviation [GV]). The study sample consisted of 228 patients (mean age 78.4 (SD 10.1) years, 51% women). Of these, 96 patients (42.1%) were treated with sliding-scale regular insulin only. Median time to start of scheduled insulin therapy was 4 (95% CI, 2-6) days. Blood glucose control measures were: MIG 181.4 (SD 41.7) mg/dL, GV 56.3 (SD 22.6). The best model to predict MIG (R(2): .376; P<.0001) included HbA1c (b=4.96; P=.011), baseline plasma glucose (b=.056; P=.084), mean capillary blood glucose in the first 24hours (b=.154; P<.0001), home treatment (versus oral agents) with basal insulin only (b=13.1; P=.016) or more complex (pre-mixed insulin or basal-bolus) regimens (b=19.1; P=.004), corticoid therapy (b=14.9; P=.002), and fasting on admission (b=10.4; P=.098). Predictors of inpatient blood glucose control which should be considered in the design of DM management protocols include home treatment, HbA1c, basal plasma glucose, mean blood glucose in the first 24hours, fasting, and corticoid therapy. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  1. Application of optical coherence tomography for noninvasive blood glucose monitoring during hyperglycemia

    Science.gov (United States)

    Larin, Kirill V.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2003-10-01

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from Diabetes Mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for chemical analysis. Recently we proposed to use optical coherence tomography (OCT) for continuous noninvasive blood glucose sensing through skin. In this paper we tested the OCT technique for noninvasive monitoring of blood glucose concentration in lip tissue of New Zealand rabbits and Yucatan micropigs during glucose clamping experiments. Obtained results show good agreement with results obtained in skin studies, good correlation of changes in the OCT signal slope measured at the depth of 250 to 500 μm with changes in blood glucose concentration, and higher stability of the OCT data points than that obtained from skin.

  2. Effect of two different regimes of carbohydrate and protein on performance and serum level of insulin and glucose in soccer players

    Directory of Open Access Journals (Sweden)

    M. Hozoori

    2006-07-01

    Full Text Available Background: The aim of this study was to determine the effect of two different regimes, containing different carbohydrate to protein ratios on performance, serum glucose and insulin after exercise in soccer players in Tehran; Iran. Methods: Nineteen male soccer players under training [age = 17/5 +/- 1.5 (SE yr] were selected and completed two sequential trials separated by 1 week, in a paired cross-over study design. In each trial, subjects after running to fatigue; received one of three regimes, using a random- order design as follows: HPRO ( CHO 56%, PRO 19% & fat 25% of total energy; HCHO ( CHO 64%, PRO 11% & fat 25% of total energy or control ( CHO 60%, PRO 15% & fat 25% of total energy. The calorie of 3 regimes were equal. After consumption of meal up to120 min, blood was obtained before and at intervals. After 3 hours athlete performance was measured. Results: The study indicates no significant difference in the serum insulin and glucose response among three regimes (P > 0.05. There was no difference in performance between three regimes after 3 h (p > 0.05. Conclusion: The results suggest that post exercise regimes have no influence on performance, serum glucose and serum insulin. Thus total energy content and carbohydrate content may be important in recovery after exercise.

  3. Lactation performance and serum biochemistry of dairy cows fed ...

    African Journals Online (AJOL)

    Serum biochemistry concentrations (serum glucose, cholesterol, triglyceride, total protein, and cortisol and insulin concentration) and blood hematology (red blood cell, hematocrit, hemoglobin concentration and percentage neutrophils, lymphocytes, monocytes, basophiles, eosinophils and ratio of neutrophils to ...

  4. Control of Blood Glucose for People with Type 1 Diabetes: an in Vivo Study

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Schmidt, Signe; Duun-Henriksen, Anne Katrine

    2012-01-01

    Since continuous glucose monitoring (CGM) technology and insulin pumps have improved recent years, a strong interest in a closed-loop articial pancreas for people with type 1 diabetes has arisen. Presently, a fully automated controller of blood glucose must face many challenges, such as daily...... variations of patient's physiology and lack of accuracy of glucose sensors. In this paper we design and discuss an algorithm for overnight closed-loop control of blood glucose in people with type 1 diabetes. The algorithm is based on Model Predictive Control (MPC). We use an oset-free autoregressive model...

  5. Is reducing variability of blood glucose the real but hidden target of intensive insulin therapy?

    Science.gov (United States)

    Egi, Moritoki; Bellomo, Rinaldo; Reade, Michael C

    2009-01-01

    Since the first report that intensive insulin therapy reduced mortality in selected surgical critically ill patients, lowering of blood glucose levels has been recommended as a means of improving patient outcomes. In this initial Leuven trial, blood glucose control by protocol using insulin was applied to 98.7% of patients in the intensive group but to only 39.2% (P dimension of glucose management, a possible mechanism by which an intensive insulin protocol exerts its putative beneficial effects, and an important goal of glucose management in the intensive care unit. Clinicians need to be aware of this controversy when considering the application of intensive insulin therapy and interpreting future trials.

  6. Changes in blood glucose among trained normoglycemic adults during a mini-trampoline exercise session.

    Science.gov (United States)

    Martins Cunha, Raphael; Raiana Bentes, Mariana; Araújo, Victor H; DA Costa Souza, Mayara C; Vasconcelos Noleto, Marcelo; Azevedo Soares, Ademar; Machado Lehnen, Alexandre

    2016-12-01

    Blood glucose changes response during and after exercise are modulated by the postabsorptive state, intensity and duration of exercise, and the level of physical fitness as well. This study focused on the idea that high-intensity interval exercise, as mini-trampoline class, can reduce blood glucose. Thus, we examined acute changes in blood glucose among trained normoglycemic adults during a mini-trampoline exercise session. Twenty-four normoglycemic adult subjects were enrolled in the study. After physical assessment they were randomly assigned to either the experimental (N.=12) or the control group (N.=12). The experimental group performed a 50-minute session of moderate-to-high intensity (70 to 85% HRmax) exercise on a mini-trampoline commonly used in fitness classes. The control group did not perform any exercise, and all procedures were otherwise similar to the experimental group. Capillary blood glucose was measured before and every 15 minutes during the exercise session. The effects of exercise on blood glucose levels (group; time; and group interaction) were estimated using a generalized estimating equation (GEE) followed by Bonferroni's post-hoc Test (Ptrampoline can be used for reducing blood glucose levels and thus can potentially control blood glucose.

  7. High glucose impairs superoxide production from isolated blood neutrophils

    DEFF Research Database (Denmark)

    Perner, A; Nielsen, S E; Rask-Madsen, J

    2003-01-01

    Superoxide (O(2)(-)), a key antimicrobial agent in phagocytes, is produced by the activity of NADPH oxidase. High glucose concentrations may, however, impair the production of O(2)(-) through inhibition of glucose-6-phosphate dehydrogenase (G6PD), which catalyzes the formation of NADPH. This study...... measured the acute effects of high glucose or the G6PD inhibitor dehydroepiandrosterone (DHEA) on the production of O(2)(-) from isolated human neutrophils....

  8. Blood Glucose Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Glucose Monitoring; 317 p. National Cancer ...

  9. The experiences of diabetics on self-monitoring of blood glucose: a qualitative metasynthesis.

    Science.gov (United States)

    Chen, Chen-Mei; Chang Yeh, Mei

    2015-03-01

    To interpret, describe and analyse the results of various qualitative studies and comprehensively elucidate the self-monitoring of blood glucose experiences of diabetic patients, and to make recommendations based on these findings for clinical practices. Patients exhibited both positive and negative perceptions towards the self-monitoring of blood glucose. Numerous recent qualitative studies have explored the self-monitoring of blood glucose experiences of diabetic patients; however, no integrated results have been provided. Qualitative metasynthesis. A systematic literature search of English and Chinese databases was undertaken, covering the period between January 2004 and April 2014. The following databases were searched: CINAHL, PubMed, MEDLINE, Cochrane Library, Airiti library and PsycInfo. Seven studies were assessed in the final analysis; the Joanna Briggs Institute Qualitative Assessment and Review Instrument was used to evaluate these studies. The self-monitoring experiences of patients with diabetes were divided into five themes: perceived disease severity, effects on daily life, lifestyle adjustments after becoming aware of blood glucose levels, determining the meaning of self-monitoring, and the differences between diabetic patients who use and do not use insulin. Individual differences in blood glucose self-monitoring vary widely among diabetic patients. These differences result from personal cognition and feelings concerning blood glucose monitoring. Insights into and discussions regarding the self-monitoring of blood glucose experiences of diabetic patients enable health care professionals to understand the factors that influence the intentions of patients to perform self-monitoring of blood glucose and facilitate establishing customised self-monitoring of blood glucose treatment plans. Health care professionals must adopt flexible and individualised criteria to determine patient cognitive misconceptions, understand negative emotional reactions and

  10. Identification of Genetic on Blood Serum Protein of Prolific Ewes

    Science.gov (United States)

    Sutiyono; Ondho, Y. S.; Setiatin, E. T.; Sutopo; Laily, A. N.; Prasetyowati, D. E.; Noviani, F.

    2018-02-01

    The aim of the research was to identify the genetic specification of blood plasma protein in ewes that are prolific. The material of study of local sheep in Bawen and Jambu Sub-district of Semarang Regency is 132 which is determined by purposive sampling that have been give lambing three times. Ewes were divided into three groups that always has a single child (L1), ever had twins (L2) and twins more than two (LM2). Blood sampling was performed using dispossible syringe in jugular vein as much as 5 ml per ewe. Blood plasma was analyzed by Polyacrylamide Gel Electrophoresis-Thin Layer (PAGETLE) method in Biochemistry Laboratory of Veterinary Faculty of Gadjah Mada University. Data analysis is using descriptive statistics and the laws of equilibrium Hardy-Weberg. The research parameters were comparison type of ewes and frequency genetic of protein of blood serum. The results showed that the parent comparisons of L1, L2 and LM2 were 66 (50.00%), 49 (37.12%) and 17 (12.88%), respectively. The frequency genes haven a high propensity to relationship of prolificacy nature parent are Pal2, AlbB, CPF, TFB, PTFS and AmlB on pointes, 67.65, 55.88, 91.17, 70.59, 79.41 and 91.18%. Conclusion the mostly LM2 ewes have genotypes Pal1Pal2, AlbBAlbC, CpFCpF, TfATfB, PtfSPtfS and AmlBAmlB whit frequency are 52.94%, 52.94%, 88.24, 47.06, 64.71 and 88.24% respectively.

  11. Blood Glucose Levels in Diabetic Patients Following Corticosteroid Injections into the Subacromial Space of the Shoulder.

    Science.gov (United States)

    Aleem, Alexander W; Syed, Usman Ali M; Nicholson, Thema; Getz, Charles L; Namdari, Surena; Beredjiklian, Pedro K; Abboud, Joseph A

    2017-09-01

    Corticosteroid injections are used to treat a variety of orthopedic conditions with the goal of decreasing pain and inflammation. Administration of systemic or local corticosteroids risks temporarily increasing blood glucose levels, especially diabetic patients. The purpose of this study is to quantify the effects of corticosteroid injections on blood glucose levels in diabetic patients with shoulder pathology. Diabetic patients who regularly monitored their blood glucose levels and were indicated for a subacromial corticosteroid injection were included in this prospective investigation. The typical normal morning fasting glucose and most recent hemoglobin A1c level was recorded for each patient. After injection, patients were contacted daily to confirm their fasting morning glucose level for 10 days post-injection. Seventeen consecutive patients were enrolled. Patients with hemoglobin A1c of patients' glucose levels returned to near baseline levels around post-injection day 8, while poorly controlled patients levels remained elevated. Similarly, insulin-dependent diabetic patients had an average increase in fasting glucose level of 99 mg/dL versus 50 mg/dL in non-insulin-dependent diabetic patients ( P patients with well-controlled diabetes experience smaller elevations and faster return to baseline glucose levels than patients with poor control. Insulin dependent diabetics experienced similar findings as patients with poor control. Future studies are needed to evaluate dosing to optimize the risks of blood glucose elevation while maintaining therapeutic benefit.

  12. Glucose Transporters at the Blood-Brain Barrier: Function, Regulation and Gateways for Drug Delivery.

    Science.gov (United States)

    Patching, Simon G

    2017-03-01

    Glucose transporters (GLUTs) at the blood-brain barrier maintain the continuous high glucose and energy demands of the brain. They also act as therapeutic targets and provide routes of entry for drug delivery to the brain and central nervous system for treatment of neurological and neurovascular conditions and brain tumours. This article first describes the distribution, function and regulation of glucose transporters at the blood-brain barrier, the major ones being the sodium-independent facilitative transporters GLUT1 and GLUT3. Other GLUTs and sodium-dependent transporters (SGLTs) have also been identified at lower levels and under various physiological conditions. It then considers the effects on glucose transporter expression and distribution of hypoglycemia and hyperglycemia associated with diabetes and oxygen/glucose deprivation associated with cerebral ischemia. A reduction in glucose transporters at the blood-brain barrier that occurs before the onset of the main pathophysiological changes and symptoms of Alzheimer's disease is a potential causative effect in the vascular hypothesis of the disease. Mutations in glucose transporters, notably those identified in GLUT1 deficiency syndrome, and some recreational drug compounds also alter the expression and/or activity of glucose transporters at the blood-brain barrier. Approaches for drug delivery across the blood-brain barrier include the pro-drug strategy whereby drug molecules are conjugated to glucose transporter substrates or encapsulated in nano-enabled delivery systems (e.g. liposomes, micelles, nanoparticles) that are functionalised to target glucose transporters. Finally, the continuous development of blood-brain barrier in vitro models is important for studying glucose transporter function, effects of disease conditions and interactions with drugs and xenobiotics.

  13. Internet-Based Contingency Management to Improve Adherence with Blood Glucose Testing Recommendations for Teens with Type 1 Diabetes

    Science.gov (United States)

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2…

  14. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects.

    Science.gov (United States)

    Vahidi, O; Kwok, K E; Gopaluni, R B; Knop, F K

    2016-09-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main drawback of the former model was its restriction on the route of glucose entrance to the body which was limited to the intravenous glucose injection. To handle the oral glucose intake, we have added a model of glucose absorption in the gastrointestinal tract to the former model to address the resultant variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data obtained during oral glucose tolerance test and isoglycemic intravenous glucose infusion test from both type 2 diabetic and healthy subjects to estimate the model parameters and to validate the model results. The estimation of model parameters is accomplished through solving a nonlinear optimization problem. The results show acceptable precision of the estimated model parameters and demonstrate the capability of the model in accurate prediction of the body response during the clinical studies.

  15. Barriers to blood glucose monitoring in a multiethnic community.

    Science.gov (United States)

    Zgibor, Janice C; Simmons, David

    2002-10-01

    We studied a multiethnic community to determine factors associated with blood glucose monitoring (BGM) and to determine the independent association between barriers to diabetes care and BGM. A total of 323 participants (35.6% European, 32.2% Maori, and 32.2% Pacific Islander) from the South Auckland Diabetes Project (free of major complications by self-report) completed a qualitative survey to determine barriers to diabetes care. Five barriers to diabetes care categories were generated including internal psychological (self efficacy/health beliefs), external psychological (psychosocial environment), internal physical (comorbidities/side effects of treatment), external physical (finance/access to care), and educational (knowledge of diabetes/services) barriers. Characteristics associated with BGM greater than or equal to twice weekly were female sex, HbA(1c) >8%, higher diabetes knowledge scores, and insulin use. Multivariate analyses demonstrated that those reporting external physical barriers (OR 0.47, 95% CI 0.26-0.84), external psychological barriers (0.55, 0.30-1.0), and internal psychological barriers (0.56, 0.32-1.0) were less likely to perform BGM independent of ethnicity, insulin use, age, sex, diabetes knowledge, and glycemic control. Further multivariate analyses demonstrated that those reporting external physical barriers, particularly related to personal finance, were less likely to perform BGM. These data demonstrate that patient-reported barriers to diabetes care are associated with BGM, particularly in relation to financial, psychosocial, and self-efficacy issues. Understanding these barriers and overcoming them within the context of the patient's ethnic environment may lead to increased participation in self-care.

  16. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob L.; Kurzban, Robert

    2016-01-01

    The academic and public interest in blood glucose and its relationship to decision making has been increasing over the last decade. To investigate and evaluate competing theories about this relationship, we conducted a psychometric meta-analysis on the effect of blood glucose on decision making. We...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money...

  17. Effect of buspirone: An anxiolytic drug on blood glucose in humans

    OpenAIRE

    Ojha, S. K.; Nandave, M.; Sharma, C.

    2006-01-01

    The present study investigated the effect of an antianxiety drug, buspirone on blood glucose and plasma insulin level concerning the role of 5-HT1A receptors in blood glucose regulation in healthy humans. Twelve healthy male volunteers were administered single oral doses of buspirone (10 mg) or placebo, in a randomized, crossover way, followed by oral glucose load (75 gm in 200 ml) at reported Tmax i.e. the time of peak plasma concentration of the respective administered drug. The blood sampl...

  18. Effect of ground cinnamon on postprandial blood glucose concentration in normal-weight and obese adults.

    Science.gov (United States)

    Magistrelli, Ashley; Chezem, Jo Carol

    2012-11-01

    In healthy normal-weight adults, cinnamon reduces blood glucose concentration and enhances insulin sensitivity. Insulin resistance, resulting in increased fasting and postprandial blood glucose and insulin levels, is commonly observed in obese individuals. The objective of the study was to compare declines in postprandial glycemic response in normal-weight and obese subjects with ingestion of 6 g ground cinnamon. In a crossover study, subjects consumed 50 g available carbohydrate in instant farina cereal, served plain or with 6 g ground cinnamon. Blood glucose concentration, the main outcome measure, was assessed at minutes 0, 15, 30, 45, 60, 90, and 120. Repeated-measures analysis of variance evaluated the effects of body mass index (BMI) group, dietary condition, and time on blood glucose. Paired t-test assessed blood glucose at individual time points and glucose area under the curve (AUC) between dietary conditions. Thirty subjects between the ages of 18 and 30 years, 15 with BMIs between 18.5 and 24.9 and 15 with BMIs of 30.0 or more, completed the study. There was no significant difference in blood glucose between the two BMI groups at any time point. However, in a combined analysis of all subjects, the addition of cinnamon to the cereal significantly reduced 120-minute glucose AUC (P=0.008) and blood glucose at 15 (P=0.001), 30 (Pblood glucose was significantly higher with cinnamon consumption (Pglucose response in normal weight and obese adults. Copyright © 2012 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  19. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Science.gov (United States)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  20. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    International Nuclear Information System (INIS)

    Meshram, N. D.; Dahikar, P. B.

    2014-01-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  1. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com [Mathuradas Mohota College of Sciences, Nagpur-440009 (India); Dahikar, P. B., E-mail: pbdahikar@rediffmail.com [Kamla Nehru Mahavidyalaya, Sakkardara Square, Nagpur-440009 (India)

    2014-10-15

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  2. Effect of blood glucose level on acute stress response of grass carp Ctenopharyngodon idella.

    Science.gov (United States)

    Jiang, Danli; Wu, Yubo; Huang, Di; Ren, Xing; Wang, Yan

    2017-10-01

    Stress has a considerable impact on welfare and productivity of fish, and blood glucose level of fish may be a factor modulating stress response. This study evaluated the effect of blood glucose level and handling on acute stress response of grass carp Ctenopharyngodon idella. Fish were intraperitoneally injected with glucose at 0, 0.2, 0.5, and 1.0 mg g -1 body mass (BM) and then were exposed to handling for 5 min. Glucose injection resulted in increase of plasma glucose level and liver glycogen content and decrease of plasma lactate level. Handling resulted in increase of plasma levels of cortisol, glucose, and lactate and plasma lactic dehydrogenase (LDH) activity and decrease of liver glycogen content. At 1 h post-stress, the plasma cortisol level was lower in the stressed fish injected with glucose at 0.5 mg g -1 BM than the stressed fish injected with glucose at 0, 0.2, and 1.0 mg g -1 BM. No significant differences were found in the activities of phosphoenolpyruvate carboxykinase (PEPCK) and pyruvate kinase (PK) in the liver between the stressed and unstressed fish, regardless of the dose of glucose injection. At 1 h post-stress, the liver glucose-6-phosphatase (G6Pase) activity was higher in the fish without glucose injection than in the fish injected with glucose. This study reveals that blood glucose level can affect stress response of grass carp by modulating cortisol release and glucose homeostasis through glycogen metabolism and gluconeogenesis in the liver.

  3. The modulatory role of spinally located histamine receptors in the regulation of the blood glucose level in d-glucose-fed mice.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kim, Sung-Su; Kim, Chea-Ha; Kim, Su-Jin; Lim, Su-Min; Jung, Jun-Sub; Ryu, Ohk-Hyun; Choi, Moon-Gi; Suh, Hong-Won

    2014-02-01

    The possible roles of spinal histamine receptors in the regulation of the blood glucose level were studied in ICR mice. Mice were intrathecally (i.t.) treated with histamine 1 (H1) receptor agonist (2-pyridylethylamine) or antagonist (cetirizine), histamine 2 (H2) receptor agonist (dimaprit) or antagonist (ranitidine), histamine 3 (H3) receptor agonist (α-methylhistamine) or antagonist (carcinine) and histamine 4 (H4) receptor agonist (VUF 8430) or antagonist (JNJ 7777120), and the blood glucose level was measured at 30, 60 and 120 min after i.t. administration. The i.t. injection with α-methylhistamine, but not carcinine slightly caused an elevation of the blood glucose level. In addition, histamine H1, H2, and H4 receptor agonists and antagonists did not affect the blood glucose level. In D-glucose-fed model, i.t. pretreatment with cetirizine enhanced the blood glucose level, whereas 2-pyridylethylamine did not affect. The i.t. pretreatment with dimaprit, but not ranitidine, enhanced the blood glucose level in D-glucose-fed model. In addition, α-methylhistamine, but not carcinine, slightly but significantly enhanced the blood glucose level D-glucose-fed model. Finally, i.t. pretreatment with JNJ 7777120, but not VUF 8430, slightly but significantly increased the blood glucose level. Although histamine receptors themselves located at the spinal cord do not exert any effect on the regulation of the blood glucose level, our results suggest that the activation of spinal histamine H2 receptors and the blockade of spinal histamine H1 or H3 receptors may play modulatory roles for up-regulation and down-regulation, respectively, of the blood glucose level in D-glucose fed model.

  4. [PROGNOSTIC SIGNIFICANCE OF CHANGES OF BLOOD GLUCOSE LEVEL IN PATIENTS WITH THORACOABDOMINAL INJURIES.

    Science.gov (United States)

    Sorokin, E P; Ponomarev, S V; Shilyaeva, Ye V; Bel'skih, Ye A; Gritsan, A I

    2016-07-01

    Background Currently, one of the causes of high morbidity and mortality is injuries. Predict the outcome of injuries - it is an important task of the treating physician. Trauma is a stress factor so to predict the outcome, you can use markers of stress, the most accessible ofwhich is blood glucose. to reveal the dynamics of the relationship between blood glucose levels and the outlook for the life ofpatients with thoracoabdominal injuries. A retrospective analysis of medical records of hospitalized patients were divided into two groups, depending on the outlook for the life of (favorable or unfavorable), and each of the groups - into two subgroups according to the presence or absence of signs of intoxication at admission. The subgroups were calculated and compared the mean blood glucose levels at different hours of hospital treatment. It was found that the average blood glucose levels at various hours of hospital stay were significantly higher in patients with poor outcome. The most noticeable was the difference in the first days of hospital treatment. Signs of intoxication was associated with lower values of glucose and a tendency to hypoglycaemia. In addition, among patients with high blood glucose ( 8 mg / dL) was observed over deaths in the first day of hospital stay. High blood glucose levels ( 8,0 mmol / L) in the first day of hospital treatment is a predictor ofpoor outcome in patients with thoracoabdominal injuries.

  5. Plasma Glucose Level Is Predictive of Serum Ammonia Level After Retrograde Occlusion of Portosystemic Shunts.

    Science.gov (United States)

    Ishikawa, Tsuyoshi; Aibe, Yuki; Matsuda, Takashi; Iwamoto, Takuya; Takami, Taro; Sakaida, Isao

    2017-09-01

    of blood ammonia levels by BRTO alone may be difficult in patients with glucose intolerance.

  6. The modulatory role of alpha-melanocyte stimulating hormone administered spinally in the regulation of blood glucose level in d-glucose-fed and restraint stress mouse models.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kim, Sung-Su; Lim, Su-Min; Jung, Jun-Sub; Suh, Hong-Won

    2014-08-01

    Alpha-melanocyte stimulating hormone (α-MSH) is known as a regulator of the blood glucose homeostasis and food intake. In the present study, the possible roles of α-MSH located in the spinal cord in the regulation of the blood glucose level were investigated in d-glucose-fed and immobilization stress (IMO) mouse models. We found in the present study that intrathecal (i.t.) injection with α-MSH alone did not affect the blood glucose level. However, i.t. administration with α-MSH reduced the blood glucose level in d-glucose-fed model. The plasma insulin level was increased in d-glucose-fed model and was further increased by α-MSH, whereas α-MSH did not affect plasma corticosterone level in d-glucose-fed model. In addition, i.t. administration with glucagon alone enhanced blood glucose level and, i.t. injection with glucagon also increased the blood glucose level in d-glucose-fed model. In contrasted to results observed in d-glucose-fed model, i.t. treatment with α-MSH caused enhancement of the blood glucose level in IMO model. The plasma insulin level was increased in IMO model. The increased plasma insulin level by IMO was reduced by i.t. treatment with α-MSH, whereas i.t. pretreatment with α-MSH did not affect plasma corticosterone level in IMO model. Taken together, although spinally located α-MSH itself does not alter the blood glucose level, our results suggest that the activation of α-MSH system located in the spinal cord play important modulatory roles for the reduction of the blood glucose level in d-glucose fed model whereas α-MSH is responsible for the up-regulation of the blood glucose level in IMO model. The enhancement of insulin release may be responsible for modulatory action of α-MSH in down-regulation of the blood glucose in d-glucose fed model whereas reduction of insulin release may be responsible for modulatory action of α-MSH in up-regulation of the blood glucose in IMO model. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Changes in Blood Values of Glucose, Insulin and Inorganic Phosphorus in Healthy and Ketotic Dairy Cows after Intravenous Infusion of Propionate Solution

    Directory of Open Access Journals (Sweden)

    R. Djoković

    2007-01-01

    Full Text Available The aim of the present study was to determine the degree of blood glucose utilization by peripheral tissue on the basis of changes in blood concentrations of glucose, insulin and inorganic phosphorus in healthy (n = 10 and ketotic cows (n = 10 after intravenous infusion of propionate solution. Blood samples were taken in both groups of examined cows at the following time intervals: just before (time 0 and 8, 30, 60, 120, 180, 240 and 480 min after the intravenous infusion of 1.84 mol l-1 solution of propionate in the amount of 1 ml kg-1 of body weight. Glucose and insulin blood serum values in both groups of cows increased significantly within 120 min of the experiment (p p p p < 0.05 in blood value of inorganic phosphorus in ketotic cows in comparison with healthy ones. This is linked with the active entry of glucose into glucolytic pathway of peripheral tissues. It can thus be concluded that there is a higher degree of blood glucose utilization by peripheral tissues in ketotic cows.

  8. Exogenous glucagon-like peptide-1 attenuates glucose absorption and reduces blood glucose concentration after small intestinal glucose delivery in critical illness.

    Science.gov (United States)

    Miller, Asaf; Deane, Adam M; Plummer, Mark P; Cousins, Caroline E; Chapple, Lee-Anne S; Horowitz, Michael; Chapman, Marianne J

    2017-03-01

    To evaluate the effect of exogenous glucagonlike peptide-1 (GLP-1) on small intestinal glucose absorption and blood glucose concentrations during critical illness. A prospective, blinded, placebo-controlled, cross-over, randomised trial in a mixed medical-surgical adult intensive care unit, with 12 mechanically ventilated critically ill patients, who were suitable for receiving small intestinal nutrient. On consecutive days, in a randomised order, participants received intravenous GLP-1 (1.2 pmol/ kg/min) or placebo (0.9% saline) as a continuous infusion over 270 minutes. After 6 hours of fasting, intravenous infusions of GLP-1 or placebo began at T = -30 min (in which T = time), with the infusion maintained at a constant rate until study completion at T = 240 min. At T = 0 min, a 100 mL bolus of mixed liquid nutrient meal (1 kcal/mL) containing 3 g of 3-O-methyl-D-gluco-pyranose (3-OMG), a marker of glucose absorption, was administered directly into the small intestine, via a post-pyloric catheter, over 6 minutes. Blood samples were taken at regular intervals for the measurement of plasma glucose and 3-OMG concentrations. Intravenous GLP-1 attenuated initial small intestinal glucose absorption (mean area under the curve [AUC] 0-30 for 3-OMG: GLP-1 group, 4.4 mmol/L/min [SEM, 0.9 mmol/L/min] v placebo group, 6.5 mmol/L/min [SEM, 1.0 mmol/L/min]; P = 0.01), overall small intestinal glucose absorption (mean AUC 0-240 for 3-OMG: GLP-1, 68.2 mmol/L/ min [SEM, 4.7 mmol/L/min] v placebo, 77.7 mmol/L/min [SEM, 4.4 mmol/lLmin]; P = 0.02), small intestinal glucose absorption and overall blood glucose concentration (mean AUC 0-240 for blood glucose: GLP-1, 2062 mmol/L/min [SEM, 111 mmol/L/min] v placebo 2328 mmol/L/min [SEM, 145 mmol/L/min]; P = 0.005). Short-term administration of exogenous GLP-1 reduces small intestinal glucose absorption for up to 4 hours during critical illness. This is likely to be an additional mechanism for the glucose-lowering effect of this agent.

  9. Regional brain glucose metabolism and blood flow in streptozocin-induced diabetic rats

    International Nuclear Information System (INIS)

    Jakobsen, J.; Nedergaard, M.; Aarslew-Jensen, M.; Diemer, N.H.

    1990-01-01

    Brain regional glucose metabolism and regional blood flow were measured from autoradiographs by the uptake of [ 3 H]-2-deoxy-D-glucose and [ 14 C]iodoantipyrine in streptozocin-induced diabetic (STZ-D) rats. After 2 days of diabetes, glucose metabolism in the neocortex, basal ganglia, and white matter increased by 34, 37, and 8%, respectively, whereas blood flow was unchanged. After 4 mo, glucose metabolism in the same three regions was decreased by 32, 43, and 60%. This reduction was paralleled by a statistically nonsignificant reduction in blood flow in neocortex and basal ganglia. It is suggested that the decrease of brain glucose metabolism in STZ-D reflects increased ketone body oxidation and reduction of electrochemical work

  10. Non-invasive blood glucose monitor based on spectroscopy using a smartphone.

    Science.gov (United States)

    Dantu, Vishnu; Vempati, Jagannadh; Srivilliputhur, Srinivasan

    2014-01-01

    Development of a novel method for non-invasive measurement of blood glucose concentration using smartphone is discussed. Our research work has three major contributions to society and science. First, we modified and extended the Beer-Lambert's law in physics to accommodate for multiple wavelengths. This extension can aid researchers who wish to perform optical spectroscopy. Second, we successfully developed a creative and non-invasive way for diabetic patients to measure glucose levels via a smartphone. Researchers and chemists can now use their smartphones to determine the absorbance and, therefore, concentration of a chemical. Third, we created an inexpensive way to perform optical spectroscopy by using a smartphone. Monitoring blood glucose using a smartphone application that simply uses equipment already available on smartphones will improve the lives of diabetic patients who can continuously check their blood glucose levels while avoiding the current inconvenient, unhygienic, and costly invasive glucose meters.

  11. Performance Analysis of Fuzzy-PID Controller for Blood Glucose Regulation in Type-1 Diabetic Patients.

    Science.gov (United States)

    Yadav, Jyoti; Rani, Asha; Singh, Vijander

    2016-12-01

    This paper presents Fuzzy-PID (FPID) control scheme for a blood glucose control of type 1 diabetic subjects. A new metaheuristic Cuckoo Search Algorithm (CSA) is utilized to optimize the gains of FPID controller. CSA provides fast convergence and is capable of handling global optimization of continuous nonlinear systems. The proposed controller is an amalgamation of fuzzy logic and optimization which may provide an efficient solution for complex problems like blood glucose control. The task is to maintain normal glucose levels in the shortest possible time with minimum insulin dose. The glucose control is achieved by tuning the PID (Proportional Integral Derivative) and FPID controller with the help of Genetic Algorithm and CSA for comparative analysis. The designed controllers are tested on Bergman minimal model to control the blood glucose level in the facets of parameter uncertainties, meal disturbances and sensor noise. The results reveal that the performance of CSA-FPID controller is superior as compared to other designed controllers.

  12. Copeptin, a surrogate marker for arginine vasopressin secretion, is associated with higher glucose and insulin concentrations but not higher blood pressure in obese men

    DEFF Research Database (Denmark)

    Asferg, C L; Andersen, Ulrik Bjørn; Linneberg, A

    2014-01-01

    distribution. METHODS: In 103 obese men (mean age ± standard deviation: 49.4 ± 10.2 years) and 27 normal weight control men (mean age: 51.5 ± 8.4 years), taking no medication, we measured 24-h ambulatory blood pressure, fasting blood concentrations of copeptin, lipids, glucose and insulin, and determined body...... blood pressure (r = 0.11, P = 0.29), 24-h diastolic blood pressure (r = 0.11, P = 0.28), BMI (r = 0.09, P = 0.37), total body fatness percentage (r = 0.10, P = 0.33), android fat mass percentage (r = 0.04, P = 0.66) or serum triglyceride concentrations (r = 0.04; P = 0.68). In contrast, plasma copeptin......, and is associated with abnormalities in glucose and insulin metabolism, but not with higher blood pressure or an android fat distribution in obese men....

  13. Fasting plasma glucose and serum uric acid levels in a general Chinese population with normal glucose tolerance: A U-shaped curve.

    Directory of Open Access Journals (Sweden)

    Yunyang Wang

    Full Text Available Although several epidemiological studies assessed the relationship between fasting plasma glucose (FPG and serum uric acid (SUA levels, the results were inconsistent. A cross-sectional study was conducted to investigate this relationship in Chinese individuals with normal glucose tolerance.A total of 5,726 women and 5,457 men with normal glucose tolerance were enrolled in the study. All subjects underwent a 75-g oral glucose tolerance test. Generalized additive models and two-piecewise linear regression models were applied to assess the relationship.A U-shaped relationship between FPG and SUA was observed. After adjusting for potential confounders, the inflection points of FPG levels in the curves were 4.6 mmol/L in women and 4.7 mmol/L in men respectively. SUA levels decreased with increasing fasting plasma glucose concentrations before the inflection points (regression coefficient [β] = -36.4, P < 0.001 for women; β = -33.5, P < 0.001 for men, then SUA levels increased (β = 17.8, P < 0.001 for women; β = 13.9, P < 0.001 for men. Additionally, serum insulin levels were positively associated with FPG and SUA (P < 0.05.A U-shaped relationship between FPG and SUA levels existed in Chinese individuals with normal glucose tolerance. The association is partly mediated through serum insulin levels.

  14. Fish protein intake induces fast-muscle hypertrophy and reduces liver lipids and serum glucose levels in rats.

    Science.gov (United States)

    Kawabata, Fuminori; Mizushige, Takafumi; Uozumi, Keisuke; Hayamizu, Kohsuke; Han, Li; Tsuji, Tomoko; Kishida, Taro

    2015-01-01

    In our previous study, fish protein was proven to reduce serum lipids and body fat accumulation by skeletal muscle hypertrophy and enhancing basal energy expenditure in rats. In the present study, we examined the precise effects of fish protein intake on different skeletal muscle fiber types and metabolic gene expression of the muscle. Fish protein increased fast-twitch muscle weight, reduced liver triglycerides and serum glucose levels, compared with the casein diet after 6 or 8 weeks of feeding. Furthermore, fish protein upregulated the gene expressions of a fast-twitch muscle-type marker and a glucose transporter in the muscle. These results suggest that fish protein induces fast-muscle hypertrophy, and the enhancement of basal energy expenditure by muscle hypertrophy and the increase in muscle glucose uptake reduced liver lipids and serum glucose levels. The present results also imply that fish protein intake causes a slow-to-fast shift in muscle fiber type.

  15. Effect of pertussis toxin pretreated centrally on blood glucose level induced by stress.

    Science.gov (United States)

    Suh, Hong-Won; Sim, Yun-Beom; Park, Soo-Hyun; Sharma, Naveen; Im, Hyun-Ju; Hong, Jae-Seung

    2016-09-01

    In the present study, we examined the effect of pertussis toxin (PTX) administered centrally in a variety of stress-induced blood glucose level. Mice were exposed to stress after the pretreatment of PTX (0.05 or 0.1 µg) i.c.v. or i.t. once for 6 days. Blood glucose level was measured at 0, 30, 60 and 120 min after stress stimulation. The blood glucose level was increased in all stress groups. The blood glucose level reached at maximum level after 30 min of stress stimulation and returned to a normal level after 2 h of stress stimulation in restraint stress, physical, and emotional stress groups. The blood glucose level induced by cold-water swimming stress was gradually increased up to 1 h and returned to the normal level. The intracerebroventricular (i.c.v.) or intrathecal (i.t.) pretreatment with PTX, a Gi inhibitor, alone produced a hypoglycemia and almost abolished the elevation of the blood level induced by stress stimulation. The central pretreatment with PTX caused a reduction of plasma insulin level, whereas plasma corticosterone level was further up-regulated in all stress models. Our results suggest that the hyperglycemia produced by physical stress, emotional stress, restraint stress, and the cold-water swimming stress appear to be mediated by activation of centrally located PTX-sensitive G proteins. The reduction of blood glucose level by PTX appears to due to the reduction of plasma insulin level. The reduction of blood glucose level by PTX was accompanied by the reduction of plasma insulin level. Plasma corticosterone level up-regulation by PTX in stress models may be due to a blood glucose homeostatic mechanism.

  16. LX4211 increases serum glucagon-like peptide 1 and peptide YY levels by reducing sodium/glucose cotransporter 1 (SGLT1)-mediated absorption of intestinal glucose.

    Science.gov (United States)

    Powell, David R; Smith, Melinda; Greer, Jennifer; Harris, Angela; Zhao, Sharon; DaCosta, Christopher; Mseeh, Faika; Shadoan, Melanie K; Sands, Arthur; Zambrowicz, Brian; Ding, Zhi-Ming

    2013-05-01

    LX4211 [(2S,3R,4R,5S,6R)-2-(4-chloro-3-(4-ethoxybenzyl)phenyl)-6-(methylthio)tetrahydro-2H-pyran-3,4,5-triol], a dual sodium/glucose cotransporter 1 (SGLT1) and SGLT2 inhibitor, is thought to decrease both renal glucose reabsorption by inhibiting SGLT2 and intestinal glucose absorption by inhibiting SGLT1. In clinical trials in patients with type 2 diabetes mellitus (T2DM), LX4211 treatment improved glycemic control while increasing circulating levels of glucagon-like peptide 1 (GLP-1) and peptide YY (PYY). To better understand how LX4211 increases GLP-1 and PYY levels, we challenged SGLT1 knockout (-/-) mice, SGLT2-/- mice, and LX4211-treated mice with oral glucose. LX4211-treated mice and SGLT1-/- mice had increased levels of plasma GLP-1, plasma PYY, and intestinal glucose during the 6 hours after a glucose-containing meal, as reflected by area under the curve (AUC) values, whereas SGLT2-/- mice showed no response. LX4211-treated mice and SGLT1-/- mice also had increased GLP-1 AUC values, decreased glucose-dependent insulinotropic polypeptide (GIP) AUC values, and decreased blood glucose excursions during the 6 hours after a challenge with oral glucose alone. However, GLP-1 and GIP levels were not increased in LX4211-treated mice and were decreased in SGLT1-/- mice, 5 minutes after oral glucose, consistent with studies linking decreased intestinal SGLT1 activity with reduced GLP-1 and GIP levels 5 minutes after oral glucose. These data suggest that LX4211 reduces intestinal glucose absorption by inhibiting SGLT1, resulting in net increases in GLP-1 and PYY release and decreases in GIP release and blood glucose excursions. The ability to inhibit both intestinal SGLT1 and renal SGLT2 provides LX4211 with a novel dual mechanism of action for improving glycemic control in patients with T2DM.

  17. Optical coherence tomography for glucose monitoring in blood

    Science.gov (United States)

    Ullah, Hafeez; Hussain, Fayyaz; Ikram, Masroor

    2015-08-01

    In this review, we have discussed the potential application of the emerging imaging modality, i.e., optical coherence tomography (OCT) for glucose monitoring in biological tissues. OCT provides monitoring of glucose diffusion in different fibrous tissues like in sclera by determining the permeability rate with acceptable accuracy both in type 1 and in type 2 diabetes. The maximum precision of glucose measurement in Intralipid suspensions, for example, with the OCT technique yields the accuracy up to 4.4 mM for 10 % Intralipid and 2.2 mM for 3 % Intralipid.

  18. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  19. Effects of blood glucose level on FDG uptake by liver: a FDG-PET/CT study

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Kazuo, E-mail: kkubota@cpost.plala.or.j [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Watanabe, Hiroshige; Murata, Yuji [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan); Yukihiro, Masashi; Ito, Kimiteru; Morooka, Miyako; Minamimoto, Ryogo [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Hori, Ai [Department of Epidemiology and International Health, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Shibuya, Hitoshi [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan)

    2011-04-15

    In FDG-PET for abdominal malignancy, the liver may be assumed as an internal standard for grading abnormal FDG uptake both in early images and in delayed images. However, physiological variables of FDG uptake by the liver, especially the effects of blood glucose level, have not yet been elucidated. Methods: FDG-PET studies of 70 patients examined at 50 to 70 min after injection (60{+-}10 min: early images) and of 68 patients examined at 80 to 100 min after injection (90{+-}10 min: delayed images) were analyzed for liver FDG uptake. Patients having lesions in the liver, spleen and pancreas; patients having bulk tumor in other areas; and patients early after chemotherapy or radiotherapy were excluded; also, patients with blood glucose level over 125 mg/dl were excluded. Results: Mean standardized uptake value (SUV) of the liver, blood glucose level and sex showed no significant differences between early images and delayed images. However, liver SUV in the delayed image showed a larger variation than that in the early image and showed significant correlation to blood glucose level. The partial correlation coefficient between liver SUV and blood glucose level in the delayed image with adjustment for sex and age was 0.73 (P<.0001). Multivariate regression coefficient (95% confidence interval) of blood glucose was 0.017 (0.013-0.021). Conclusion: Blood glucose level is an important factor affecting the normal liver FDG uptake in nondiabetic patients. In the case of higher glucose level, liver FDG uptake is elevated especially in the delayed image. This may be due to the fact that the liver is the key organ responsible for glucose metabolism through gluconeogenesis and glycogen storage.

  20. Dimethylarginines, blood glucose, and C-reactive protein in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Aurélie Gudjoncik

    2016-04-01

    Conclusion: Our study showed that in patients with acute MI, SDMA, and only weakly ADMA, are associated with admission blood glucose, beyond traditional dimethylarginine determinants and may therefore have biological activity beyond renal function.

  1. Effect of blood glucose level on 18F-FDG PET/CT imaging

    International Nuclear Information System (INIS)

    Tan Haibo; Lin Xiangtong; Guan Yihui; Zhao Jun; Zuo Chuantao; Hua Fengchun; Tang Wenying

    2008-01-01

    Objective: The aim of this study was to investigate the effect of blood glucose level on the image quality of 18 F-fluorodeoxyglucose (FDG) PET/CT imaging. Methods: Eighty patients referred to the authors' department for routine whole-body 18 F-FDG PET/CT check up were recruited into this study. The patients were classified into 9 groups according to their blood glucose level: normal group avg and SUV max ) of liver on different slices. SPSS 12.0 was used to analyse the data. Results: (1) There were significant differences among the 9 groups in image quality scores and image noises (all P avg and SUV max : 0.60 and 0.33, P<0.05). Conclusions: The higher the blood glucose level, the worse the image quality. When the blood glucose level is more than or equal to 12.0 mmol/L, the image quality will significantly degrade. (authors)

  2. Lowering blood glucose during hip surgery does not influence coagulation activation

    Directory of Open Access Journals (Sweden)

    Marjolein K. Sechterberger

    2015-06-01

    Conclusion: Although the human GLP-1 analogue liraglutide moderately reduced post-operative blood glucose levels in non-diabetic and prediabetic obese patients undergoing elective hip surgery, no changes were observed with respect to coagulation activation.

  3. Effects of self-monitoring of blood glucose on diabetes control in a ...

    African Journals Online (AJOL)

    Methods:This study assessed the effect on diabetes control in patients who received glucometers and education ... Self-monitoring of blood glucose (SMBG) helps patients make ..... unhealthy eating habits could possibly be related to the low.

  4. Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

    Science.gov (United States)

    De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson

    2016-08-01

    As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.

  5. Clinical implication of blood glucose monitoring in general dental offices: the Ehime Dental Diabetes Study

    OpenAIRE

    Harase, Tadahiro; Nishida, Wataru; Hamakawa, Tomohiro; Hino, Satoshi; Shigematsu, Kenji; Kobayashi, Satoru; Sako, Hirofumi; Ito, Shirou; Murakami, Hajime; Nishida, Kei; Inoue, Hiroshi; Fujisawa, Masahito; Yoshizu, Hiroshi; Kawamura, Ryoichi; Takata, Yasunori

    2015-01-01

    Objective We examined whether general dentists can contribute to the detection of patients with undiagnosed diabetes and prediabetes by monitoring blood glucose in dental clinics. Research design and methods A total of 716 patients who visited clinics for dental treatment were enrolled and classified into 3 groups (mild, moderate, and severe) according to Kornman's criteria for periodontitis. The correlations between the casual blood glucose level, presence or absence of the history of diabet...

  6. Depletion of norepinephrine of the central nervous system Down-regulates the blood glucose level in d-glucose-fed and restraint stress models.

    Science.gov (United States)

    Park, Soo-Hyun; Kim, Sung-Su; Lee, Jae-Ryeong; Sharma, Naveen; Suh, Hong-Won

    2016-05-04

    DSP-4[N-(2-chloroethyl)-N-ethyl-2-bromobenzylamine hydrochloride] is a neurotoxin that depletes norepinephrine. The catecholaminergic system has been implicated in the regulation of blood glucose level. In the present study, the effect of DSP-4 administered intracerebroventricularly (i.c.v.) or intrathecally (i.t.) on blood glucose level was examined in d-glucose-fed and restraint stress mice models. Mice were pretreated once i.c.v. or i.t. with DSP-4 (10-40μg) for 3days, and d-glucose (2g/kg) was fed orally. Blood glucose level was measured 0 (prior to glucose feeding or restraint stress), 30, 60, and 120min after d-glucose feeding or restraint stress. The i.c.v. or i.t. pretreatment with DSP-4 attenuated blood glucose level in the d-glucose-fed model. Plasma corticosterone level was downregulated in the d-glucose-fed model, whereas plasma insulin level increased in the d-glucose-fed group. The i.c.v. or i.t. pretreatment with DSP-4 reversed the downregulation of plasma corticosterone induced by feeding d-glucose. In addition, the d-glucose-induced increase in plasma insulin was attenuated by the DSP-4 pretreatment. Furthermore, i.c.v. or i.t. pretreatment with DSP-4 reduced restraint stress-induced increases in blood glucose levels. Restraint stress increased plasma corticosterone and insulin levels. The i.c.v. pretreatment with DSP-4 attenuated restraint stress-induced plasma corticosterone and insulin levels. Our results suggest that depleting norepinephrine at the supraspinal and spinal levels appears to be responsible for downregulating blood glucose levels in both d-glucose-fed and restraint stress models. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Comparison of blood electrolytes and glucose during cardiopulmonary bypass in diabetic and non-diabetic patients

    Directory of Open Access Journals (Sweden)

    Golamreza Maasoumi

    2013-01-01

    Full Text Available Background: Cardiopulmonary bypass (CPB during coronary artery bypass grafting is thought to contribute significantly to increased blood glucose level and altered blood electrolytes balance during the operation. In this (CABG study, blood electrolytes and glucose during CPB in insulin-dependent diabetic and non-diabetic patients were assessed with special emphasis on the trend of the changes. Materials and Methods: Blood glucose and electrolytes were assessed in 30 insulin-dependent diabetic and 30 non-diabetic patients, classified as class II and III American Society of Anesthesiologist, before, during, and after CPB. Repeated-measures analysis of variance (ANOVA was used to compare the trend of the changes during CPB for the two groups. Results: The trend in blood glucose level did not show any significant difference between two groups ( P = 0.59. For other blood factors, no significant between-group difference was detected except for PaCO 2 ( P = 0.002. Conclusion: The study suggested that the changes in blood electrolytes and the increase in blood glucose level do not differ between insulin dependent diabetic and non-diabetic patients.

  8. Effects of 1 and 3 g cinnamon on gastric emptying, satiety, and postprandial blood glucose, insulin, glucose-dependent insulinotropic polypeptide, glucagon-like peptide 1, and ghrelin concentrations in healthy subjects

    DEFF Research Database (Denmark)

    Hlebowicz, Joanna; Hlebowicz, Anna; Lindstedt, Sandra

    2009-01-01

    glucose, plasma concentrations of insulin and incretin hormones [glucose-dependent insulinotropic polypeptide (GIP) and glucagon-like peptide 1 (GLP-1)], the ghrelin response, and satiety in healthy subjects. DESIGN: GER was measured by using real-time ultrasonography after ingestion of rice pudding...... with and without 1 or 3 g cinnamon. Fifteen healthy subjects were assessed in a crossover trial. RESULTS: The addition of 1 or 3 g cinnamon had no significant effect on GER, satiety, glucose, GIP, or the ghrelin response. The insulin response at 60 min and the area under the curve (AUC) at 120 min were...... cinnamon (P = 0.0082 and P = 0.0138, respectively, after Bonferroni correction). CONCLUSIONS: Ingestion of 3 g cinnamon reduced postprandial serum insulin and increased GLP-1 concentrations without significantly affecting blood glucose, GIP, the ghrelin concentration, satiety, or GER in healthy subjects...

  9. Dextrose in the banked blood products does not seem to affect the blood glucose levels in patients undergoing liver transplantation

    Science.gov (United States)

    Cheng, Kwok-Wai; Chen, Chao-Long; Cheng, Yu-Fan; Tseng, Chia-Chih; Wang, Chih-Hsien; Chen, Yaw-Sen; Wang, Chih-Chi; Huang, Tung-Liang; Eng, Hock-Liew; Chiu, King-Wah; Wang, Shih-Hor; Lin, Chih-Che; Lin, Tsan-Shiun; Liu, Yueh-Wei; Jawan, Bruno

    2005-01-01

    AIM: Hyperglycemia commonly seen in liver transplantation (LT) has often been attributed to the dextrose in the storage solution of blood transfusion products. The purpose of the study is to compare the changes of the blood glucose levels in transfused and non-transfused patients during LT. METHODS: A retrospective study on 60 biliary pediatric patients and 16 adult patients undergoing LT was carried out. Transfused pediatric patients were included in Group I (GI), those not transfused in Group II (GII). Twelve adult patients were not given transfusion and assigned to Group III (GIII); whereas, four adult patients who received massive transfusion were assigned to Group IV (GIV). The blood glucose levels, volume of blood transfused, and the volume of crystalloid infused were recorded, compared and analyzed. RESULTS: Results showed that the changes in blood glucose levels during LT for both non-transfused and minimally transfused pediatric groups and non-transfused and massively-transfused adult groups were almost the same. CONCLUSION: We conclude that blood transfusion does not cause significant changes in the blood glucose levels in this study. PMID:15884124

  10. Alanine aminotransferase is associated with an adverse nocturnal blood glucose profile in individuals with normal glucose regulation.

    Directory of Open Access Journals (Sweden)

    Jian Zhou

    Full Text Available OBJECTIVE: Although the association between alanine aminotransferase (ALT levels and risk of type 2 diabetes is well-studied, the effects of slightly increased ALT levels within the normal range on the temporal normal glucose profile remains poorly understood. METHODS: A total of 322 Chinese subjects without impaired glucose tolerance or previous diagnoses of diabetes were recruited for study from 10 hospitals in urban areas across China. All subjects wore a continuous glucose monitoring (CGM system for three consecutive days. The diurnal (06∶00-20∶00 and nocturnal (20∶00-06∶00 mean blood glucose (MBG levels were calculated. Subjects were stratified by ALT quartile level and correlation analyses were performed. RESULTS: The median ALT level was 17 IU/L, and subjects with ALT ≥17 IU/L had higher nocturnal MBG level than those with ALT 0.05. Multivariate stepwise regression analysis of elevated nocturnal MBG identified increased HOMA-IR, elevated ALT levels, and decreased homeostatic model assessment of ß-cell function as independent factors (all, P<0.05. CONCLUSIONS: Mildly elevated ALT levels, within the normal range, are associated with unfavorable nocturnal glucose profiles in Chinese subjects with normal glucose regulation.

  11. Cerebrospinal fluid ionic regulation, cerebral blood flow, and glucose use during chronic metabolic alkalosis

    International Nuclear Information System (INIS)

    Schroeck, H.K.; Kuschinsky, W.

    1989-01-01

    Chronic metabolic alkalosis was induced in rats by combining a low K+ diet with a 0.2 M NaHCO3 solution as drinking fluid for either 15 or 27 days. Local cerebral blood flow and local cerebral glucose utilization were measured in 31 different structures of the brain in conscious animals by means of the iodo-[14C]antipyrine and 2-[14C]deoxy-D-glucose method. The treatment induced moderate [15 days, base excess (BE) 16 mM] to severe (27 days, BE 25 mM) hypochloremic metabolic alkalosis and K+ depletion. During moderate metabolic alkalosis no change in cerebral glucose utilization and blood flow was detectable in most brain structures when compared with controls. Cerebrospinal fluid (CSF) K+ and H+ concentrations were significantly decreased. During severe hypochloremic alkalosis, cerebral blood flow was decreased by 19% and cerebral glucose utilization by 24% when compared with the control values. The decrease in cerebral blood flow during severe metabolic alkalosis is attributed mainly to the decreased cerebral metabolism and to a lesser extent to a further decrease of the CSF H+ concentration. CSF K+ concentration was not further decreased. The results show an unaltered cerebral blood flow and glucose utilization together with a decrease in CSF H+ and K+ concentrations at moderate metabolic alkalosis and a decrease in cerebral blood flow and glucose utilization together with a further decreased CSF H+ concentration at severe metabolic alkalosis

  12. Waist circumference as a predictor for blood glucose levels in adults

    Directory of Open Access Journals (Sweden)

    Shinta L Hardiman

    2016-02-01

    Full Text Available Anthropometric indexes such as body mass index (BMI, waist circumference (WC, hip ciucumference (HC, and waist–hip ratio (WHR, are all useful anthropometric measurements to provide important information on blood glucose concentrations. The aim of this study was to determine different anthropometric measurements, in particular BMI, waist circumference, hip circumference and waist-to-hip ratio, in their ability to predict the blood glucose levels in men and women 40 to 60. A cross-sectional study was conducted on a sample of 44 men and 127 women aged 40 to 50 who lived in Cipete Selatan subdistrict, South Jakarta. Blood glucose levels was assessed and anthropometric measurements comprising BMI, WC, HC, WHR were collected. Multiple linear regression analysis was used to determine the best predictor for blood glucose levels. The study showed that the prevalence of DM type 2 was 25.7% and the prevalence was higher in men (40.9% compared to women (23.5%. The significant predictive variables in the simple regression analysis were age and waist circumference. Multiple linear regression showed that after adjustment for age, WC was positively associated with blood glucose levels. Standardized a value was 0.172 (p=0.026. WC predict blood glucose levels, beyond that explained by traditional diabetic risk factors and BMI. These findings provide support for the recommendation that WC be a routine measure for identification of diabetes mellitus type 2 in men and women aged 40 to 60 years.

  13. EFFECT OF SAPPAN WOOD (Caesalpinnia sappan L EXTRACT ON BLOOD GLUCOSE LEVEL IN WHITE RATS

    Directory of Open Access Journals (Sweden)

    Saefudin Saefudin

    2016-05-01

    Full Text Available Sappan wood or kayu secang (Caesalpinia sappan L. was reported of having medicinal properties, such as natural antioxidant, relieve vomiting of blood, and mix of ingredients for malaria drugs. The research was conducted to study the influence of ethanol extract from sappan wood on blood glucose level of white rats. The study of the blood glucose level in rats was carried out by using glucose tolerance method. It was measured by Refloluxs (Accutrend GC with Chloropropamide 50 mg/200 g BW (Body weight as positive control. The ethanol extracts were used in various concentrations 10, 20, 30, 40 and 50 mg/200 g BW per-oral and was observed every hour, beginning one hour before to 7 hours after the extract being administered. The results showed that treatment of ethanol extract of sappan wood by administer doses gave remarkable effect on the blood glucose level in white rat. It reduced the glucose level in the blood compared to the negative and positive control. Treatment of dose 30 mg/200 g BW gave similar effect to positive controls, while a dose of 50 mg/200 g BW gave lower blood glucose level (93 mg/dl than the positive controls.

  14. Blood glucose control for patients with acute coronary syndromes in Qatar.

    Science.gov (United States)

    Wilby, Kyle John; Elmekaty, Eman; Abdallah, Ibtihal; Habra, Masa; Al-Siyabi, Khalid

    2016-01-01

    Blood glucose is known to be elevated in patients presenting with acute coronary syndromes. However a gap in knowledge exists regarding effective management strategies once admitted to acute care units. It is also unknown what factors (if any) predict elevated glucose values during initial presentation. OBJECTIVES of the study were to characterize blood glucose control in patients admitted to the cardiac care unit (CCU) in Qatar and to determine predictive factors associated with high glucose levels (>10 mmol/l) on admission to the CCU. All data for this study were obtained from the CCU at Heart Hospital in Doha, Qatar. A retrospective chart review was completed for patients admitted to the CCU in Qatar from October 1st, 2012 to March 31st, 2013, of which 283 were included. Baseline characteristics (age, gender, nationality, medical history, smoking status, type of acute coronary syndrome), capillary and lab blood glucose measurements, and use of insulin were extracted. Time spent in glucose ranges of 10 mmol/1 was calculated manually. Univariate and multivariate logistic regression were performed to assess factors associated with high glucose on admission. The primary analysis was completed with capillary data and a sensitivity analysis was completed using laboratory data. Blood glucose values measured on admission and throughout length of stay in the CCU. Capillary blood glucose data showed majority of time was spent in the range of >10 mmol/l (41.95%), followed by 4-8 mmol/l (35.44%), then 8-10 mmol/l (21.45%), and finally 10 mmol/l on admission (p < 0.05) in a univariate analysis but only diabetes remained significant in a multivariate model (OR 23.3; 95% CI, 11.5-47.3). Diabetes predicts high glucose values on hospital admission for patients with ACS and patients are not being adequately controlled throughout CCU stay.

  15. Uric Acid or 1-Methyl Uric Acid in the Urinary Bladder Increases Serum Glucose, Insulin, True Triglyceride, and Total Cholesterol Levels in Wistar Rats

    Directory of Open Access Journals (Sweden)

    T. Balasubramanian

    2003-01-01

    Full Text Available In animals deprived of food for a long period, a drop in the fat mass below 5% of the total body mass results in an increase in blood glucocorticoids and uric acid levels, followed by foraging activity. Since the glucocorticoids increase the uric acid excretion, an increase in the level of uric acid in the bladder urine could be the signal for this feeding behaviour and subsequent fat storage. Accumulation of fat is associated with hyperglycaemia, hyperinsulinaemia, hyperlipidaemia, and hypercholesterolaemia as seen in the metabolic syndrome or hibernation. It is hypothesized that uric acid or its structurally related compound, 1-methyl uric acid (one of the metabolites of the methyl xanthines namely caffeine, theophylline, and theobromine present in coffee, tea, cocoa, and some drugs, can act on the urinary bladder mucosa and increases the blood glucose, insulin, triglyceride, and cholesterol levels. In rats, perfusion of the urinary bladder with saturated aqueous solution of uric acid or 1-methyl uric acid results in a significant increase in the serum levels of glucose, insulin, true triglyceride, and total cholesterol in comparison with perfusion of the bladder with distilled water at 20, 40, and 80 min. The uric acid or the 1-methyl uric acid acts on the urinary bladder mucosa and increases the serum glucose, insulin, true triglyceride, and total cholesterol levels.

  16. The effect of an instant hand sanitizer on blood glucose monitoring results.

    Science.gov (United States)

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-11-01

    People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. In our study

  17. CCQM-K11.2 determination of glucose in human serum and CCQM-K12.2 determination of creatinine in human serum

    Science.gov (United States)

    Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pritchett, Jeanita; Pabello, Guiomar; Avila Calderon, Marco A.; Balderas, Miryan; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Monteiro, Tânia; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Peignaux, Maryline; Kawaguchi, Migaku; Bei, Xu; Can, Quan; Nammoonnoy, Jintana; Schild, Katrin; Ohlendorf, Rüdiger; Henrion, Andre; Ceyhan Gören, Ahmet; Yılmaz, Hasibe; Bilsel, Mine; Konopelko, L.; Krylov, A.; Lopushanskaya, E.

    2018-01-01

    Glucose and creatinine are two of the most frequently measured substances in human blood/serum for assessing the health status of individuals. Because of their clinical significance, CCQM-K11 glucose in human serum and CCQM-K12 creatinine in human serum were the fourth and fifth key comparisons (KCs) performed by the Organic Analysis Working Group (OAWG). These KCs were conducted in parallel and were completed in 2001. The initial subsequent KCs for glucose, CCQM-K11.1, and creatinine, CCQM-K12.1, were completed in 2005. Measurements for the next KCs for these two measurands, CCQM-K11.2 and CCQM-K12.2, were completed in 2013. While designed as subsequent KCs, systematic discordances between the participants' and the anchor institution's results in both comparisons lead the OAWG to request reference results from two experienced laboratories that had participated in the 2001 comparisons. Based on the totality of the available information, the OAWG converted both CCQM-K11.2 and CCQM-K12.2 to 'Track C' KCs where the key comparison reference value is estimated by consensus. These comparisons highlighted that carrying out comparisons for complex chemical measurements and expecting to be able to treat them under the approaches used for formal CIPM subsequent comparisons is not an appropriate strategy. The approach used here is a compromise to gain the best value from the comparison; it is not an approach that will be used in the future. Instead, the OAWG will focus on Track A and Track C comparisons that are treated as stand-alone entities. Participation in CCQM-K11.2 demonstrates a laboratory's capabilities to measure a polar (pKow > 2), low molecular mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (0.1 mg/g to 10 mg/g). Participation in CCQM-K12.2 demonstrates capabilities to measure similar classes of metabolites at relatively low concentrations (1 μg/g to 30 μg/g). The capabilities required for the analysis of complex

  18. [Effect of raw and cooked nopal (Opuntia ficus indica) ingestion on growth and profile of total cholesterol, lipoproteins, and blood glucose in rats].

    Science.gov (United States)

    Cárdenas Medellín, M L; Serna Saldívar, S O; Velazco de la Garza, J

    1998-12-01

    Two different concentrations (approx. 6 and 12%) and two presentations (raw and cooked) of dehydrated nopal were fed to laboratory rats and growth and serum total cholesterol, lipoprotein profile and glucose determined. Samples of raw and cooked nopal were chemically characterized for moisture, protein, ash, crude fiber, ether extract, total dietary fiber, reducing sugars, amino acids, minerals and gross energy. Cooking slightly affected some of the nutrients analyzed. After one month feeding, blood was withdrawn via intracardiac puncture and serum glucose, total cholesterol, HDL, LDL, and VLDL were determined. Rats fed 12% nopal had lower weight gains (P nopal or the control diet. Consumption of nopal did not affect (P > 0.05) glucose, total cholesterol and HDL cholesterol levels. However, rats fed raw nopal at the 12% concentration level had a 34% reduction in LDL cholesterol levels; thus, it was concluded that raw nopal had a potentially beneficial effect for hypercholesterolemic individuals.

  19. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Science.gov (United States)

    Mortazavi, SMJ; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, AR

    2014-01-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors. PMID:25505778

  20. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2014-09-01

    Full Text Available Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students, blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2 while the phone was ringing. For Control- Repeat group (15 students, two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (ΔC in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test. To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors.

  1. Low blood glucose precipitates spike-and-wave activity in genetically predisposed animals.

    Science.gov (United States)

    Reid, Christopher A; Kim, Tae Hwan; Berkovic, Samuel F; Petrou, Steven

    2011-01-01

    Absence epilepsies are common, with a major genetic contribution to etiology. Certain environmental factors can influence absence occurrence but a complete understanding of absence precipitation is lacking. Herein we investigate if lowering blood glucose increases spike-wave activity in mouse models with varying seizure susceptibility. Three mouse models were used: an absence seizure model based on the knockin of a human GABA(A) γ2(R43Q) mutation (DBA(R43Q)), the spike-wave discharge (SWD)-prone DBA/2J strain, and the seizure resistant C57Bl/6 strain. Electrocorticography (ECoG) studies were recorded to determine SWDs during hypoglycemia induced by insulin or overnight fasting. An insulin-mediated reduction in blood glucose levels to 4 mm (c.a. 40% reduction) was sufficient to double SWD occurrence in the DBA(R43Q) model and in the SWD-prone DBA/2J mouse strain. Larger reductions in blood glucose further increased SWDs in both these models. However, even with large reductions in blood glucose, no discharges were observed in the seizure-resistant C57Bl/6 mouse strain. Injection of glucose reversed the impact of insulin on SWDs in the DBA(R43Q) model, supporting a reduction in blood glucose as the modulating influence. Overnight fasting reduced blood glucose levels to 4.5 mm (c.a. 35% reduction) and, like insulin, caused a doubling in occurrence of SWDs. Low blood glucose can precipitate SWDs in genetically predisposed animal models and should be considered as a potential environmental risk factor in patients with absence epilepsy. Wiley Periodicals, Inc. © 2010 International League Against Epilepsy.

  2. Analysis of blood glucose distribution characteristics in a health examination population in Chengdu (2007–2015)

    OpenAIRE

    Huang, Wenxia; Xu, Wangdong; Zhu, Ping; Yang, Hanwei; Su, Linchong; Tang, Huairong; Liu, Yi

    2017-01-01

    Abstract With socioeconomic growth and cultural changes in China, the level of blood glucose may have changed in recent years. This study aims to detect the blood glucose distribution characteristics with a large size of health examination population. A total of 641,311 cases (360,259 males and 281,052 females) more than 18 years old during 2007 to 2015 were recruited from the Health Examination Center at West China hospital, Sichuan University. The percentage of cases with abnormal glucose l...

  3. A cross-sectional study of the relationship between serum liver enzymes level and the incidence of impaired fasting glucose in males and females.

    Science.gov (United States)

    Qin, Guangming; Lu, Lihong; Xiao, Yufei; Zhu, Yimiao; Pan, Wensheng; Xu, Xiang; Shen, Shengrong; Das, Undurti N

    2014-07-28

    The aim of this study was to investigate the possible correlation between levels of serum liver enzymes and impaired fasting glucose (IFG) in Chinese adults and to provide a new perspective for the prevention of pre-diabetes. Serum liver enzymes of the samples including alanine aminotransferase (ALT), aspartate aminotransferase (AST), and g-glutamyl transferase (GGT), as well as plasma glucose, blood lipids, and insulin, were measured. The cumulative incidences of IFG between different quartiles of liver enzymes were compared by the chi-square test. A logistic regression model (binary regression) was used to calculate the odds ratio (OR) of IFG with 95% confidence interval (95% CI). The total incidence of IFG was 20.3% and the cumulative incidence of IFG was higher in men compared to women. In both sexes, IFG is more prevalent in higher quartiles of liver enzymes. After adjusting for age, BMI, blood pressure, triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), and total cholesterol (TC), the cumulative incidences of IFG were significantly higher in the highest quartiles of liver enzymes than in the lowest quartiles. A significantly higher cumulative incidence of IFG was found in the highest GGT quartile than in the lowest quartile for woman. The results of this study suggest that serum liver enzymes are related to the risk of IFG in Chinese adults. We infer that preserving the hepatic function may be an efficient way to prevent the development of IFG, especially in males.

  4. The association between Western and Prudent dietary patterns and fasting blood glucose levels in type 2 diabetes and normal glucose metabolism in older Australian adults.

    Science.gov (United States)

    Walsh, Erin I; Jacka, Felice N; Butterworth, Peter; Anstey, Kaarin J; Cherbuin, Nicolas

    2017-06-01

    High blood glucose and type 2 diabetes are associated with a range of adverse health and cognitive outcomes. One factor that contributes to high blood glucose and type 2 diabetes is dietary intake. This study investigated the relationship between dietary patterns, fasting blood glucose and diabetes status in a sample of 209 participants aged 60-65. Blood plasma glucose was measured from venous blood samples. Individual Prudent and Western dietary patterns were estimated from a self-completed food frequency questionnaire. The relationship between dietary patterns, diabetes, and blood glucose was assessed via general linear model analyses controlling for age, sex, height, and total caloric intake. Results indicated that there was no association between Prudent diet and fasting blood glucose levels, or type 2 diabetes. In contrast, an individual in the upper tertile for Western dietary score had a significantly higher risk of having diabetes than an individual in the lower tertile for Western dietary score. However, there was no significant association between Western diet and fasting blood glucose. Western diet may be associated with type 2 diabetes through mechanisms beyond impacting blood plasma glucose directly. The fact that the association between Western diet and type 2 diabetes remained even when total caloric intake was controlled for highlights the need for policy and population health interventions targeting the reduction of unhealthy food consumption.

  5. Glucose transporter of the human brain and blood-brain barrier

    International Nuclear Information System (INIS)

    Kalaria, R.N.; Gravina, S.A.; Schmidley, J.W.; Perry, G.; Harik, S.I.

    1988-01-01

    We identified and characterized the glucose transporter in the human cerebral cortex, cerebral microvessels, and choroid plexus by specific D-glucose-displaceable [3H]cytochalasin B binding. The binding was saturable, with a dissociation constant less than 1 microM. Maximal binding capacity was approximately 7 pmol/mg protein in the cerebral cortex, approximately 42 pmol/mg protein in brain microvessels, and approximately 27 pmol/mg protein in the choroid plexus. Several hexoses displaced specific [3H]cytochalasin B binding to microvessels in a rank-order that correlated well with their known ability to cross the blood-brain barrier; the only exception was 2-deoxy-D-glucose, which had much higher affinity for the glucose transporter than the natural substrate, D-glucose. Irreversible photoaffinity labeling of the glucose transporter of microvessels with [3H]cytochalasin B, followed by solubilization and polyacrylamide gel electrophoresis, labeled a protein band with an average molecular weight of approximately 55,000. Monoclonal and polyclonal antibodies specific to the human erythrocyte glucose transporter immunocytochemically stained brain blood vessels and the few trapped erythrocytes in situ, with minimal staining of the neuropil. In the choroid plexus, blood vessels did not stain, but the epithelium reacted positively. We conclude that human brain microvessels are richly endowed with a glucose transport moiety similar in molecular weight and antigenic characteristics to that of human erythrocytes and brain microvessels of other mammalian species

  6. Assessment of Blood Glucose Regulation and Safety of Resistant Starch Formula-Based Diet in Healthy Normal and Subjects With Type 2 Diabetes.

    Science.gov (United States)

    Lin, Chia-Hung; Chang, Daw-Ming; Wu, Da-Jen; Peng, Hui-Yu; Chuang, Lee-Ming

    2015-08-01

    To evaluate the effects of the new resistant starch (RS) formula, PPB-R-203, on glucose homeostasis in healthy subjects and subjects with type 2 diabetes.A cohort consisting of 40 healthy participants received test and control diets and was checked for up to 3 hours post-meal. A randomized, 2-regimen, cross-over, comparative study was conducted in 44 subjects with type 2 diabetes and glycemic control was assessed with a continuous glucose monitoring system.In healthy participants, serum glucose values and incremental areas under the glucose curves (AUC) were significantly lower in the PPB-R-203 than the control group (P blood glucose concentrations for subjects on the control regimen were higher than those for subjects on the PPB-R-203-based regimen (7.9 ± 1.7, 95% confidence interval [CI] 7.4-8.4 vs 7.4 ± 1.6, 95% CI 6.9-7.9 mmol/L, respectively; P = 0.023). AUCs for total blood glucose and hyperglycemia (glucose >10 mmol/L) were also reduced for subjects on the PPB-R-203-based regimen as compared with those on control regimen (total blood glucose: 16.2 ± 4.0, 95% CI 14.9-17.4 vs 18.7 ± 4.0, 95% CI 17.6-20.1, P AUC measurements for hypoglycemia (glucose glucose excursion.

  7. Using meta-differential evolution to enhance a calculation of a continuous blood glucose level.

    Science.gov (United States)

    Koutny, Tomas

    2016-09-01

    We developed a new model of glucose dynamics. The model calculates blood glucose level as a function of transcapillary glucose transport. In previous studies, we validated the model with animal experiments. We used analytical method to determine model parameters. In this study, we validate the model with subjects with type 1 diabetes. In addition, we combine the analytic method with meta-differential evolution. To validate the model with human patients, we obtained a data set of type 1 diabetes study that was coordinated by Jaeb Center for Health Research. We calculated a continuous blood glucose level from continuously measured interstitial fluid glucose level. We used 6 different scenarios to ensure robust validation of the calculation. Over 96% of calculated blood glucose levels fit A+B zones of the Clarke Error Grid. No data set required any correction of model parameters during the time course of measuring. We successfully verified the possibility of calculating a continuous blood glucose level of subjects with type 1 diabetes. This study signals a successful transition of our research from an animal experiment to a human patient. Researchers can test our model with their data on-line at https://diabetes.zcu.cz. Copyright © 2016 The Author. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. The Coupling of Cerebral Metabolic Rate of Glucose and Cerebral Blood Flow In Vivo

    DEFF Research Database (Denmark)

    Hasselbalch, Steen; Paulson, Olaf Bjarne

    2012-01-01

    The energy supplied to the brain by metabolic substrate is largely utilized for maintaining synaptic transmission. In this regulation cerebral blood flow and glucose consumption is tightly coupled as well in the resting condition as during activation. Quantification of cerebral blood flow...... not used for aerobic metabolism. Although some of the excess glucose uptake can be explained by lactate production, this phenomenon can still not account for the excess glucose uptake. Thus, more complex metabolic patterns in the brain might be reflected in the excess glucose uptake during activation......, and especially temporal relationships must be taken into account. What triggers the flow increase during functional brain activation is not entirely elucidated. The demand for excess glucose uptake may be important and a possible oxygen deficit in tissue distant from the capillaries is probably of minor...

  9. Influence of physical and emotional activity on the metabolic profile of blood serum of race horses

    Directory of Open Access Journals (Sweden)

    T. I. Bayeva

    2016-09-01

    Full Text Available In the article data are presented on dynamics of the level of indicators of metabolic profile of blood serum of race horses of the Ukrainian riding breed in the conditions of physical and emotional loading. Clinically healthy race horses were the object of  research. Blood was taken from the jugular vein to obtain serum and for further biochemical research. For the research 12 race horses from a training group were chosen. From time to time the animals took part in competitions; they were not specially used in races and were mostly used for the training of junior riders and sportsmen of different levels. Blood was taken in conditions of relative rest after ordinary training and after emotional stress during the entertainment performances when a large number of people were present and loud music was played. In the blood serum the following biochemical indicators were defined: whole protein, urea, creatinine, uric acid, total bilirubin and its fractions, glucose, cholestererol, triacylglycerol, calcium, ferrum, lactate, pyruvate, activity of the AlAT, SGOT, GGTP, LDH, an alkaline phosphatase – which makes it possible to determine reasonably accurately the adaptation potential of a horse under various types of loading. We established that during training and psychoemotional loading of racing horses of the training group of the Ukrainian riding breed, multidirectional changes in the level of biochemical indicators of blood serum occurred, which is evidence of stress in the metabolic processes in the animals’ organisms. Concentration of a biomarker of an oxidative stress, uric acid, increased after physical loading by 8.6%, and after emotional loading by 55.1%, which demonstrates that emotional stress had the more negative effect, indicating insufficient adaptation by the horses before demonstration performances. After physical loading, reaction of transamination in the horses’ liver cells intensified, and after emotional loading its intensity

  10. WDR1 and CLNK gene polymorphisms correlate with serum glucose and high-density lipoprotein levels in Tibetan gout patients.

    Science.gov (United States)

    Lan, Bing; Chen, Peng; Jiri, Mutu; He, Na; Feng, Tian; Liu, Kai; Jin, Tianbo; Kang, Longli

    2016-03-01

    Current evidence suggests heredity and metabolic syndrome contributes to gout progression. Specifically, the WDR1 and CLNK genes may play a role in gout progression in European ancestry populations. However, no studies have focused on Chinese populations, especially Tibetan individuals. This study aims to determine whether variations in these two genes correlate with gout-related indices in Chinese-Tibetan gout patients. Eleven single-nucleotide polymorphisms in the WDR1 and CLNK genes were detected in 319 Chinese-Tibetan gout patients and 318 controls. We used one-way analysis of variance to evaluate the polymorphisms' effects on gout based on mean serum levels of metabolism indicators, such as albumin, glucose (GLU), triglycerides, cholesterol, high-density lipoproteins (HDL-C), creatinine, and uric acid, from fasting venous blood samples. All p values were Bonferroni corrected. Polymorphisms of the WDR1 and CLNK genes affected multiple risk factors for gout development. Significant differences in serum GLU levels were detected between different genotypic groups with WDRI polymorphisms rs4604059 (p = 0.005) and rs12498927 (p = 0.005). In addition, significant differences in serum HDL-C levels were detected between different genotypic groups with the CLNK polymorphism rs2041215 (p = 0.001). Polymorphisms of CLNK also affected levels of albumin, triglycerides, and creatinine. This study is the first to investigate and identify positive correlations between WDR1 and CLNK gene polymorphisms in Chinese-Tibetan populations. Our findings provide significant evidence for the effect of genetic polymorphisms on gout-related factors in Chinese-Tibetan populations.

  11. Institutional point-of-care glucometer identifies population trends in blood glucose associated with war.

    Science.gov (United States)

    Boaz, Mona; Matas, Zipora; Chaimy, Tova; Landau, Zohar; Bar Dayan, Yosefa; Berlovitz, Yitzhak; Wainstein, Julio

    2013-11-01

    Acute physiological stress has been shown to impair glucose homeostasis. War is a period of acute psychological stress, and its effect on glucose control is unknown. In this study random point-of-care (POC) glucose levels were measured using an automated, institutional glucometer in hospitalized adult patients prior to versus during the Israeli Pillar of Defense campaign (November 7-10, 2012). Random POC glucose values measured with the institutional blood glucose monitoring system were obtained 1 week prior to the Pillar of Defense campaign (November 7-10, 2012) and compared with values to those obtained during the first 4 days of the war (November 14-17, 2012). In total, 3,573 POC glucose measures were included: 1,865 during the pre-war period and 1,708 during the campaign. POC glucose measures were significantly higher during the war compared with the week preceding the war: 9.7±4.7 versus 9.3±4.2 mmol/L (P=0.02). In a general linear model, period (pre-war vs. during war) persisted as a significant predictor of POC glucose even after controlling for age, sex, and department type (internal medicine vs. surgical). Acute stress, such as a wartime situation, is associated with a significant increase in random blood glucose values in a population of hospitalized adults. Long-term follow-up of the individuals hospitalized during these two periods can reveal differences in morbidity and mortality trends.

  12. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    Science.gov (United States)

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  13. Data Based Prediction of Blood Glucose Concentrations Using Evolutionary Methods.

    Science.gov (United States)

    Hidalgo, J Ignacio; Colmenar, J Manuel; Kronberger, Gabriel; Winkler, Stephan M; Garnica, Oscar; Lanchares, Juan

    2017-08-08

    Predicting glucose values on the basis of insulin and food intakes is a difficult task that people with diabetes need to do daily. This is necessary as it is important to maintain glucose levels at appropriate values to avoid not only short-term, but also long-term complications of the illness. Artificial intelligence in general and machine learning techniques in particular have already lead to promising results in modeling and predicting glucose concentrations. In this work, several machine learning techniques are used for the modeling and prediction of glucose concentrations using as inputs the values measured by a continuous monitoring glucose system as well as also previous and estimated future carbohydrate intakes and insulin injections. In particular, we use the following four techniques: genetic programming, random forests, k-nearest neighbors, and grammatical evolution. We propose two new enhanced modeling algorithms for glucose prediction, namely (i) a variant of grammatical evolution which uses an optimized grammar, and (ii) a variant of tree-based genetic programming which uses a three-compartment model for carbohydrate and insulin dynamics. The predictors were trained and tested using data of ten patients from a public hospital in Spain. We analyze our experimental results using the Clarke error grid metric and see that 90% of the forecasts are correct (i.e., Clarke error categories A and B), but still even the best methods produce 5 to 10% of serious errors (category D) and approximately 0.5% of very serious errors (category E). We also propose an enhanced genetic programming algorithm that incorporates a three-compartment model into symbolic regression models to create smoothed time series of the original carbohydrate and insulin time series.

  14. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...... of the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77......% of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two of ten...

  15. Blood glucose level prediction based on support vector regression using mobile platforms.

    Science.gov (United States)

    Reymann, Maximilian P; Dorschky, Eva; Groh, Benjamin H; Martindale, Christine; Blank, Peter; Eskofier, Bjoern M

    2016-08-01

    The correct treatment of diabetes is vital to a patient's health: Staying within defined blood glucose levels prevents dangerous short- and long-term effects on the body. Mobile devices informing patients about their future blood glucose levels could enable them to take counter-measures to prevent hypo or hyper periods. Previous work addressed this challenge by predicting the blood glucose levels using regression models. However, these approaches required a physiological model, representing the human body's response to insulin and glucose intake, or are not directly applicable to mobile platforms (smart phones, tablets). In this paper, we propose an algorithm for mobile platforms to predict blood glucose levels without the need for a physiological model. Using an online software simulator program, we trained a Support Vector Regression (SVR) model and exported the parameter settings to our mobile platform. The prediction accuracy of our mobile platform was evaluated with pre-recorded data of a type 1 diabetes patient. The blood glucose level was predicted with an error of 19 % compared to the true value. Considering the permitted error of commercially used devices of 15 %, our algorithm is the basis for further development of mobile prediction algorithms.

  16. Effect of levulose containing sweets on blood and salivary glucose levels.

    Science.gov (United States)

    Subramaniam, Priya; K L, Girish Babu; Gona, Harsha

    2015-06-01

    It is common that many diabetic patients crave for sweets which are normally prohibited. To satisfy their desire to have sweets, alternative sweeteners have been introduced to provide sweetness to some items of their diabetic diet. To (1) assess the effect of sweets containing levulose on glucose levels in blood and saliva, and (2) compare it with effect of sweets containing sucrose on blood and saliva levels of glucose. The study consisted of 20 healthy participants, aged 17-20 years. Two sweet preparations of 36 g each were selected for the study. One preparation was sweetened with levulose (diabetic sweet; Group I) and the other with sucrose (regular sweet; Group II). Blood sugar and salivary glucose levels were estimated before and after the consumption of diabetic and regular sweets. The mean increase in salivary glucose level was lower in Group I than in Group II. Similarly, increase in blood glucose levels in Group I was lower and highly significant. In comparison with regular sweets, consumption of levulose containing sweet resulted in significantly lower blood and salivary glucose levels.

  17. A single dual-emissive nanofluorophore test paper for highly sensitive colorimetry-based quantification of blood glucose.

    Science.gov (United States)

    Huang, Xiaoyan; Zhou, Yujie; Liu, Cui; Zhang, Ruilong; Zhang, Liying; Du, Shuhu; Liu, Bianhua; Han, Ming-Yong; Zhang, Zhongping

    2016-12-15

    Fluorescent test papers are promising for the wide applications in the assays of diagnosis, environments and foods, but unlike classical dye-absorption-based pH test paper, they are usually limited in the qualitative yes/no type of detection by fluorescent brightness, and the colorimetry-based quantification remains a challenging task. Here, we report a single dual-emissive nanofluorophore probe to achieve the consecutive color variations from blue to red for the quantification of blood glucose on its as-prepared test papers. Red quantum dots were embedded into silica nanoparticles as a stable internal standard emission, and blue carbon dots (CDs) were further covalently linked onto the surface of silica, in which the ratiometric fluorescence intensity of blue to red is controlled at 5:1. While the oxidation of glucose induced the formation of Fe(3+) ions, the blue emission of CDs was thus quenched by the electron transfer from CDs to Fe(3+), displaying a serial of consecutive color variations from blue to red with the dosage of glucose. The high-quality test papers printed by the probe ink exhibited a dosage-sensitive allochromatic capability with the clear differentiations of ~5, 7, 9, 11mM glucose in human serum (normal: 3-8mM). The blood glucose determined by the test paper was almost in accordance with that measured by a standard glucometer. The method reported here opens a window to the wide applications of fluorescent test paper in biological assays. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Assessment of three frequently used blood glucose monitoring devices in clinical routine.

    Science.gov (United States)

    Zueger, Thomas; Schuler, Vanessa; Stettler, Christoph; Diem, Peter; Christ, Emanuel R

    2012-07-12

    Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice. Capillary blood glucose was measured simultaneous using the following glucose meters: Contour® (Bayer Diabetes Care, Zürich, Switzerland), Accu-Chek® aviva (Roche Diagnostics, Rotkreuz, Switzerland), Free-Style® lite (Abbott Diabetes Care, Baar, Switzerland). The reference method consisted of the HemoCue® Glucose 201+ System (HemoCue® AB, Ängelholm, Sweden) with plasma conversion. The devices were assessed by comparison of the Mean Absolute Relative Differences (MARD), the Clarke Error Grid Analysis (EGA) and the compliance with the International Organization of Standardization criteria (ISO 15197:2003). Capillary blood samples were obtained from 150 patients. MARD was 10.1 ± 0.65%, 7.0 ± 0.62% and 7.8 ± 0.48% for Contour®, Accu-Chek® and Free-Style®, respectively. EGA showed 99.3% (Contour®), 98.7% (Accu-Chek®) and 100% (Free-Style®) of all measurements in zone A and B (clinically acceptable). The ISO criteria were fulfilled by Accu-Chek® (95.3%) and Free-Style® (96%), but not by Contour® (92%). In the present study the three glucose meters provided good agreement with the reference and reliable results in daily clinical routine. Overall, the Free-Style® and Accu-Chek® device slightly outperformed the Contour® device.

  19. Blood glucose control in the intensive care unit: benefits and risks.

    Science.gov (United States)

    Gunst, Jan; Van den Berghe, Greet

    2010-01-01

    Abnormal blood glucose levels are common during critical illness and are associated with outcomes that correspond to a J-shaped curve, the lowest risk associated with normoglycemia. Three proof-of-concept randomized-controlled-trials performed in the surgical, medical, and pediatric intensive care units of the Leuven University Hospital in Belgium demonstrated that maintaining strict age-adjusted normal fasting levels of glycemia (80-110 mg/dl in adults, 70-100 mg/dl in children, 50-80 mg/dl in infants) with intensive insulin therapy reduced morbidity and mortality as compared with tolerating stress hyperglycemia as a potentially beneficial response. Recently, concern has risen about the safety of this intervention, as a multicenter adult study reported an, as yet unexplained, increased mortality with targeting normoglycemia as compared with an intermediate blood glucose level of around 140 mg/dl. This apparent contradiction may be explained by several methodological differences among studies, comprising, among others, different glucose target ranges in the control groups, different feeding policies, and variable accuracy of tools used for glucose measurement and insulin infusion. Hence, efficacy and safety of intensive insulin therapy may be affected by patient-related and ICU setting-related variables. Therefore, no single optimal blood glucose target range for ICU patients can be advocated. It appears safe not to embark on targeting "age-normal" levels in intensive care units (ICUs) that are not equipped to accurately and frequently measure blood glucose, and have not acquired extensive experience with intravenous insulin administration using a customized guideline. A simple fallback position could be to control blood glucose levels as close to normal as possible without evoking unacceptable blood glucose fluctuations, hypoglycemia, and hypokalemia.

  20. ( Myrciaria jaboticaba ) peel on blood glucose and cholesterol levels ...

    African Journals Online (AJOL)

    Berg) peel was lyophilized and the proximate composition, total anthocyanins and polyphenolic content were determined. The effect of the freeze-dried jaboticaba peels (FJP) in the plasmatic levels of glucose, lipid fractions, aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in Wistar adult male rats was ...

  1. Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies

    Directory of Open Access Journals (Sweden)

    Kjome RL

    2010-03-01

    Full Text Available Objective: To evaluate diabetes patients’ self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. Methods: The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201+ by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. Results: During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001. Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. Conclusion: A community pharmacy-based quality assessment procedure of patients’ self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the

  2. Brain metabolism is significantly impaired at blood glucose below 6 mM and brain glucose below 1 mM in patients with severe traumatic brain injury

    OpenAIRE

    Meierhans, Roman; B?chir, Markus; Ludwig, Silke; Sommerfeld, Jutta; Brandi, Giovanna; Haberth?r, Christoph; Stocker, Reto; Stover, John F

    2010-01-01

    Introduction The optimal blood glucose target following severe traumatic brain injury (TBI) must be defined. Cerebral microdialysis was used to investigate the influence of arterial blood and brain glucose on cerebral glucose, lactate, pyruvate, glutamate, and calculated indices of downstream metabolism. Methods In twenty TBI patients, microdialysis catheters inserted in the edematous frontal lobe were dialyzed at 1 ?l/min, collecting samples at 60 minute intervals. Occult metabolic alteratio...

  3. Brain metabolism is significantly impaired at blood glucose below 6 mM and brain glucose beneath 1 mM in patients with severe traumatic brain injury.

    OpenAIRE

    Meierhans, R; Bechir, M; Ludwig, S; Sommerfeld, J; Brandi, G; Haberthur, C; Stocker, R; Stover, J F

    2010-01-01

    ABSTRACT: INTRODUCTION: The optimal blood glucose target following severe traumatic brain injury (TBI) must be defined. Cerebral microdialysis was used to investigate the influence of arterial blood and brain glucose on cerebral glucose, lactate, pyruvate, glutamate, and calculated indices of downstream metabolism. METHODS: In twenty TBI patients, microdialysis catheters inserted in the edematous frontal lobe were dialyzed at 1 mul/ min, collecting samples at 60 minute intervals. Occult metab...

  4. Social Inclusion Predicts Lower Blood Glucose and Low-Density Lipoproteins in Healthy Adults.

    Science.gov (United States)

    Floyd, Kory; Veksler, Alice E; McEwan, Bree; Hesse, Colin; Boren, Justin P; Dinsmore, Dana R; Pavlich, Corey A

    2017-08-01

    Loneliness has been shown to have direct effects on one's personal well-being. Specifically, a greater feeling of loneliness is associated with negative mental health outcomes, negative health behaviors, and an increased likelihood of premature mortality. Using the neuroendocrine hypothesis, we expected social inclusion to predict decreases in both blood glucose levels and low-density lipoproteins (LDLs) and increases in high-density lipoproteins (HDLs). Fifty-two healthy adults provided self-report data for social inclusion and blood samples for hematological tests. Results indicated that higher social inclusion predicted lower levels of blood glucose and LDL, but had no effect on HDL. Implications for theory and practice are discussed.

  5. Red blood transfusion in preterm infants: changes in glucose, electrolytes and acid base balance

    Directory of Open Access Journals (Sweden)

    Shereen Abdelghaffar

    2012-01-01

    Full Text Available Background: Preterm neonates comprise the most heavily transfused group of patients, and about 85% of extremely low birth weight newborns receive a transfusion by the end of their hospital stay. The aim of this study was to assess the possible metabolic effects of RBC transfusion on preterm infants, especially during the first 2 weeks of life, and its relation to blood volume. Materials and Methods: This study was conducted on 40 preterm neonates with gestational age of less than or equal to 34 weeks. They received RBCs transfusion during first 2 weeks of life. Venous blood samples of infants were collected 2 to 4 hours before and 1 hour after the end of transfusion to evaluate hemoglobin (Hb level, hematocrit, acid-base, electrolytes, and glucose status. Then, infants were classified into two main groups: those who received RBCs volume less than or 20 ml/kg and those who received RBCs volume more than 20 ml/kg. Results: Infants received a mean volume of 20.38 ± 3.2 ml/kg RBCs (range, 10.9 - 26.6 ml/kg at a median age of 9.8 ± 3.6 days. After transfusion, a significant increase of mean Hb (P<0.001, mean Hct (P<0.001, pH (P<0.001, pO 2 (P<0.05, and a significant decrease of the pCO2 (41.46 ± 8.8torr vs 35.4 ± 9.34 torr; P<0.001 were observed. In addition, there was a significant increase of serum K + (P<0.001, and a significant decrease of Ca +2 (P<0.001. A positive correlation was found between the K + intake and the changes of kalemia (r = 0.99; P = 0.00. Furthermore, we observed an inverse correlation between the patients′ calcium intake and the changes of calcemia (r = -0.35; P = 0.02. On comparing the changes in clinical and biochemical variables between two groups after transfusion, we observed a significant increase in mean Hb and Hct associated with a significant decrease in mean serum Ca +2 (P<0.001 in the group receiving the larger blood volume. Conclusion: RBC transfusion was effective in improving anemia, oxygenation, increasing

  6. Gingival crevicular blood for screening of blood glucose level in patients with & without diabetes: a chair-side test.

    Science.gov (United States)

    Bhavsar, M V; Brahmbhatt, N A; Sahayata, V; Bhavsar, N V

    2016-05-01

    Diabetes is a pandemic disease with increasing prevalence and serious complications. Periodontitis being one of its presentation and is its sixth recognized complication. This study compares blood glucose levels in gingival crevicular blood of patients with and without diabetes elicited during routine periodontal probing and venous blood sample. Seventy patients with moderate gingivitis and periodontitis positive for bleeding on probing were chosen. All the subjects were divided in two groups, group I consisted of 35 diabetic and group II of 35 non-diabetic subjects. Blood from the gingiva of the most inflamed site was collected with the test strip of a glucose self-monitoring device, and the blood glucose levels were measured. At the same time, intravenous blood was collected for measurement in a laboratory glucose analyzer. Gingival index and probing pocket depth were evaluated for each subject at same time. The mean GCB levels and VB derived from all samples were 156.07 ± 49.23 mg dl(-1) and 156 ± 49.89 mg dl(-1) , respectively, for diabetic group and 90.80 ± 11.07 and 93.41 ± 9.30 for non-diabetic group. In both the groups, the difference between GCB and VB glucose levels was non-significant (P > 0.005). Highly significant correlation between GCB and VB (r = 0.972 for diabetic and r = 0.721 for non-diabetic) in both the groups was found. The data from this study show that GCB collected during diagnostic periodontal examination can be an excellent source for estimation of blood sugar or glucometric analysis. This technique is also suitable for routine screening of diabetic and early diagnosis of unknown diabetic cases. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Design of a prospective clinical study on the agreement between the Continuous GlucoseMonitor, a novel device for CONTinuous ASSessment of blood GLUcose levels, and the RAPIDLab® 1265 blood gas analyser: The CONTASSGLU study

    OpenAIRE

    Zimmermann Johannes B; Lehmann Monika; Hofer Stefan; Hüsing Johannes; Alles Catharina; Werner Jens; Stiller Jürgen; Künnecke Wolfgang; Luntz Steffen; Motsch Johann; Weigand Markus A

    2012-01-01

    Abstract Background Although a device is needed to continuously measure blood glucose levels within an intensive care setting, and several large-scale prospective studies have shown that patients might benefit from intensive insulin, potassium, or glucose therapy during intensive care, no devices are currently available to continuously assess blood glucose levels in critically ill patients. We conceived the study described here to evaluate the clinical use of the Continuous Glucose Monitor (C...

  8. [Effect of a dehydrated extract of nopal (Opuntia ficus indica Mill.) on blood glucose].

    Science.gov (United States)

    Frati-Munari, A C; de León, C; Ariza-Andraca, R; Bañales-Ham, M B; López-Ledesma, R; Lozoya, X

    1989-01-01

    To assess if a dehydrated extract of nopal stems retains the effect on glycemia of the entire nopal stems two experiments were performed. A. Six patients with type II diabetes mellitus in fasting condition received 30 capsules containing 10.1 +/- 0.3 g of the extract, and serum glucose levels were measured hourly from 0 to 180 minutes. B. Six healthy volunteers received 30 capsules with the extract followed by 74 g of dextrose orally. Serum glucose measurements were made in a similar fashion. In each experiment a control test with empty capsules was performed. Nopal extract did not reduce fasting glycemia in diabetic subjects. Nevertheless, the extract diminished the increase of serum glucose which followed a dextrose load. Peak serum glucose was 20.3 +/- 18.2 mg/dl (X +/- SD) lower in the test with nopal than in the control one (P less than 0.025). Dehydrated extract of nopal (Opuntia ficus-indica Mill) did not show acute hypoglycemic effect, although could attenuate postprandial hyperglycemia.

  9. Comparison of breath gases, including acetone, with blood glucose and blood ketones in children and adolescents with type 1 diabetes.

    Science.gov (United States)

    Blaikie, Tom P J; Edge, Julie A; Hancock, Gus; Lunn, Daniel; Megson, Clare; Peverall, Rob; Richmond, Graham; Ritchie, Grant A D; Taylor, David

    2014-11-25

    Previous studies have suggested that breath gases may be related to simultaneous blood glucose and blood ketone levels in adults with type 2 and type 1 diabetes. The aims of this study were to investigate these relationships in children and young people with type 1 diabetes in order to assess the efficacy of a simple breath test as a non-invasive means of diabetes management. Gases were collected in breath bags and measurements were compared with capillary blood glucose and ketone levels taken at the same time on a single visit to a routine hospital clinic in 113 subjects (59 male, age 7 years 11 months-18 years 3 months) with type 1 diabetes. The patients were well-controlled with relatively low concentrations of the blood ketone measured (β hydroxybutyrate, 0-0.4 mmol l(-1)). Breath acetone levels were found to increase with blood β hydroxybutyrate levels and a significant relationship was found between the two (Spearman's rank correlation ρ = 0.364, p acetone (ρ = 0.16, p = 0.1), but led to the conclusion that single breath measurements of acetone do not provide a good measure of blood glucose levels in this cohort. This result suggests a potential to develop breath gas analysis to provide an alternative to blood testing for ketone measurement, for example to assist with the management of type 1 diabetes.

  10. Age-related memory impairments due to reduced blood glucose responses to epinephrine.

    Science.gov (United States)

    Morris, Ken A; Chang, Qing; Mohler, Eric G; Gold, Paul E

    2010-12-01

    Increases in blood glucose levels are an important component of the mechanisms by which epinephrine enhances memory formation. The present experiments addressed the hypothesis that a dysfunction in the blood glucose response to circulating epinephrine contributes to age-related memory impairments. Doses of epinephrine and glucagon that significantly increased blood glucose levels in young adult rats were far less effective at doing so in 2-year-old rats. In young rats, epinephrine and glucose were about equally effective in enhancing memory and in prolonging post-training release of acetylcholine in the hippocampus. However, glucose was more effective than epinephrine in enhancing both memory and acetylcholine release in aged rats. These results suggest that an uncoupling between circulating epinephrine and glucose levels in old rats may lead to an age-related reduction in the provision of glucose to the brain during training. This in turn may contribute to age-related changes in memory and neural plasticity. Copyright © 2008 Elsevier Inc. All rights reserved.

  11. A comparative study of serum uric acid, glucose, calcium and magnesium in pre-eclampsia and normal pregnancy

    Directory of Open Access Journals (Sweden)

    Arun Dhungana

    2017-09-01

    Full Text Available Background: Preeclampsia is associated with liver function abnormalities and renal function impairment. The objective of this study is to compare serum uric acid, glucose, calcium and magnesium in pre-eclampsia with normal pregnancy. Materials and Methods: Normal pregnant women and pre eclamptic women of age group 20-40 years were included. Serum magnesium, calcium, glucose, uric acid were analyzed.Results: Mean serum magnesium level in preeclampsia (1.83 ± 0.21mg/dl was lesser in comparison to normal pregnant women (2.03 ± 0.16 mg/dl. Serum calcium level was lower (8.10 ±0.56mg/dl than control (9.59 ±0.62 mg/dl with p<0.001. Uric acid, glucose and lactate dehydrogenase in preeclamptic women was significantly higher than that in normal pregnant women (6.14 ± 0.85 vs.4.01 ± 0.62, p=<0.001, (94.17± 18.65 vs.86.34 ± 10.19, p=0.033 and ( 466.80 ± 97.29 vs. 194.22 ± 39.76, p=<0.001 respectively.Conclusion: There were significant changes in serum magnesium, uric acid, calcium, glucose, lactate dehydrogenase and total protein in pregnant women.

  12. The associations of a marine diet with plasma lipids, blood glucose, blood pressure and obesity among the inuit in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, P; Pedersen, H S; Mulvad, G

    2000-01-01

    OBJECTIVE: To analyse the associations between the intake of fish and marine mammals and risk factors for cardiovascular disease, ie lipid profile, fasting blood glucose, blood pressure and obesity, in a population whose average consumption of n-3 fatty acids is high compared with Western countries...... and not statistically significant. The pattern was similar within groups with low, medium and high consumption of marine food. CONCLUSIONS: There are statistically significant associations between the consumption of marine food and certain lipid fractions in the blood also in this population with a very high average...... intake of marine food. The observation that blood glucose is positively associated with marine diet in a population survey is new and should be repeated. There was good agreement between the results for the reported consumption of seal and those for the biomarkers. SPONSORSHIP: The study was financially...

  13. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  14. Efficacy of the Hydroalcoholic Extract of Tribulus terrestris on the Serum Glucose and Lipid Profile of Women With Diabetes Mellitus: A Double-Blind Randomized Placebo-Controlled Clinical Trial.

    Science.gov (United States)

    Samani, Nasrin Babadaei; Jokar, Azam; Soveid, Mahmood; Heydari, Mojtaba; Mosavat, Seyed Hamdollah

    2016-10-01

    Considering traditional use of Tribulus terrestris in diabetes and proven antihyperglycemic and antihyperlipidemic effects of T terrestris in animal studies, we aimed to evaluate the efficacy of the hydroalcoholic extract of T terrestris on the serum glucose and lipid profile of women with non-insulin-dependent diabetes mellitus. Ninety-eight women with diabetes mellitus type 2 were randomly allocated to receive the T terrestris (1000 mg/d) or placebo for 3 months. The patients were evaluated in terms of the fasting blood glucose, 2-hour postprandial glucose, glycosylated hemoglobin, and lipid profile. Tribulus terrestris showed a significant blood glucose-lowering effect in diabetic women compared to placebo (P terrestris group was significantly reduced compared with placebo, while no significant effect was observed in the triglyceride and high-density lipoprotein levels. The study showed preliminary promising hypoglycemic effect of T terrestris in women with diabetes mellitus type 2. © The Author(s) 2016.

  15. Effect of dietary fiber in lowering serum glucose and body weight in sprague dawley rats

    Directory of Open Access Journals (Sweden)

    Muhammad Imran Chohan

    2011-08-01

    Full Text Available Introduction:The present study evaluated the hypoglycemic perspectives and weight loss significance of dietary fiber. Dietary fiber was supplemented in commercial wheat flour (atta for the preparation of chapaties, a staple diet of South Asia. Male Sprague Dawley rats (n = 100 were randomly divided into 4 diet groups (n = 25 per group. The control group was fed basal diet that included commercial wheat flour chapati, cornstarch, corn oil, salt and vitamin mixture in such a way that 10% of the protein was available from the final diet. To the basal diet of other 3 groups, chapaties supplemented with 2% guar gum (GG 2%, 3% guar gum (GG 3% and 5% chickpea + 1% guar gum (CP5%+GG1% were added, respectively. All diets were fed to the rats for a period of 8 weeks to perceive the impact of respective compositions. Rats fed on CP 5% + GG1%, showed maximum glucose reduction (14.57% followed by GG 3% (11.64% and GG 2% (9.60% as compared to control diet. Likewise, rats fed on 3% GG showed maximum decline (7.90% in body weight. It was concluded that chapaties prepared from selected treatments provide an additional dietary fiber that could be supportive for diabetic and obese individuals.Results:The results indicated that addition of dietary fiber influenced the physical characteristics of chapati non-significantly. Maximum glucose concentration was found to be 112.50 mg/dL in control group followed by 101.70 and 99.41 mg/dL in groups fed on guar gum 2% and guar gum 3%, respectively. Lowest glucose concentration (96.11 mg/dL was observed in rats fed on the combination of chickpea 5 %+ guar gum 1%. Maximum serum protein concentration was found to be 6.39 g/dL in rats fed on combination of chickpea 5 % + guar gum 1% whilst the remaining three groups showed non significant variations with respect to each other. Means for serum Functional Foods in Health and Disease 2011; 8:261-278 protein were 6.33, 6.30 and 6.32 g/dL for control, guar gum 3%, and guar gum 2

  16. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  17. Tale of two sites: capillary versus arterial blood glucose testing in the operating room.

    Science.gov (United States)

    Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O

    2012-04-01

    Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a

  18. Radioimmunoassay for measurement of thyroxine (T4) and triiodothyonine (T3) in blood serum

    International Nuclear Information System (INIS)

    Chopra, I.J.

    1975-01-01

    This invention relates to a highly accurate, rapid and simple estimation of thyroxine (T 4 ) directly from blood serum and also relates to the accurate measurement of triiodo-L-thyronine (T 3 ) directly from blood serum. More specifically, the invention relates to a rapid, specific and reliable radioimmunoassay (RIA) technique for measurement of both T 4 and T 3 in unextracted serum. The method requires very small amounts of serum, e.g., 25 microliters (μl) to measure T 4 concentration in nearly all specimens representing clinical states of eu-, hypo- and hyperthyroidism, and 250 μl to measure T 3 concentrations in specimens representing most clinical states

  19. How Effective is Swedish Massage on Blood Glucose Level in Children with Diabetes Mellitus?

    Directory of Open Access Journals (Sweden)

    Firoozeh Sajedi

    2011-09-01

    Full Text Available "nThis study was conducted to determine the effect of Swedish massage on blood glucose level in children with diabetes mellitus (DM. It was prospective randomized controlled trial study that conducted on 36 children, 6-12 years old with DM, recruited from a hospital in Qom City, Iran. The children were randomly assigned to intervention and control groups. Swedish massage was performed 15 minutes, 3 times a week, for 3 months in intervention group. The blood glucose levels were evaluated immediately after every session of massage in two groups. The mean ages of children in the intervention (n=18 and control (n=18 groups were 9.05 ± 1.55 and 9.83 ±2.03 years respectively. There was statistically no significant difference in blood glucose levels before intervention between two groups (P=0.586, but the blood glucose levels were lower significantly in intervention group in comparison with control group after intervention (P<0.0001. Addition of Swedish massage to daily routines; exercise, diet and medication regimens, is an effective intervention to reduce blood glucose level in diabetic children.

  20. Association of sleep duration with blood glucose level of Gujarati Indian adolescents.

    Science.gov (United States)

    Patel, Minal C; Shaikh, Wasim A; Singh, S K

    2012-01-01

    Recently studies conducted in various parts of the world indicate short sleep duration as a novel risk factor for development of type 2 diabetes. However, ethnic differences exist in the etiopathogenesis of diseases, the current study was undertaken to study the effect of sleep duration on the blood glucose level of Gujarati Indian adolescents. A randomized, non-experimental, cross-sectional study was done on the voluntary participants n = 332 Gujarati adolescent boys and girls of age group 13-20 years studying at the schools and colleges in the Anand district. The participants were assessed for their sleep duration, body composition and blood glucose level. The sleep duration was reported by the subjects as the number of hours they slept on most of the nights in a week over the last one-year. The observations of the study were then analyzed after grouping them into: 1) Adequate sleep duration at night, ASDN (> or = 7 hrs) and 2) Inadequate sleep duration at night, ISDN (blood glucose level between the ASDN group and ISDN group in both boys and girls. However, gender difference exists in the body composition and blood glucose level. The current study indicates that inadequate sleep duration at night (blood glucose level of the Gujarati Indian adolescents of age group 13-20 years.

  1. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    Science.gov (United States)

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  2. Local cerebral blood flow and glucose metabolism during seizure in spontaneously epileptic El mice

    International Nuclear Information System (INIS)

    Hosokawa, Chisa; Ochi, Hironobu; Yamagami, Sakae; Kawabe, Joji; Kobashi, Toshiko; Okamura, Terue; Yamada, Ryusaku

    1995-01-01

    Local cerebral blood flow and glucose metabolism were examined in spontaneously epileptic El mice using autoradiography with 125 I-IMP and 14 C-DG in the interictal phase and during seizure. El (+) mice that developed generalized tonic-clonic convulsions and El (-) mice that received no stimulation and had no history of epileptic seizures were examined. The seizure non-susceptible, maternal strain ddY mice were used as control. Uptake ratios for IMP and DG in mouse brain were calculated using the autoradiographic density. In the interictal phase, the pattern of local cerebral blood flow of El (+) mice was similar to that of ddY and El (-) mice, and glucose metabolism in the hippocampus was higher in El (+) mice than in El (-) and ddY mice, but flow and metabolism were nearly matched. During seizure, no significant changed blood flow and increased glucose metabolism in the hippocampus, the epileptic focus, and no markedly changed blood flow and depressed glucose metabolism in other brain regions were observed and considered to be flow-metabolism uncoupling. These observations have never been reported in clinical or experimental studies of epilepsy. Seizures did not cause large regional differences in cerebral blood flow. Therefore, only glucose metabolism is useful for detection of the focus of secondary generalized seizures in El mice, and appeared possibly to be related to the pathophysiology of secondary generalized epilepsy in El mice. (author)

  3. Gastric bypass surgery has a weight-loss independent effect on post-challenge serum glucose levels

    DEFF Research Database (Denmark)

    Hofsø, Dag; Birkeland, Kåre I; Holst, Jens J

    2015-01-01

    glucose tolerance test before and after either gastric bypass surgery (n = 64) or an intensive lifestyle intervention programme (n = 55), ClinicalTrials.gov identifier NCT00273104. The age-adjusted effects of the therapeutic procedures and percentage weight change on fasting and 2-h glucose levels at 1......BACKGROUND: Gastric bypass surgery seems to have an effect on glucose metabolism beyond what is mediated through weight reduction. The magnitude of this effect on fasting and post-challenge glucose levels remains unknown. RESULTS: Morbidly obese subjects without known diabetes performed a 75 g oral...... year were explored using multiple linear regression analysis. Mean (SD) serum fasting and 2-h glucose levels at baseline did not differ between the surgery and lifestyle groups. Weight-loss after surgical treatment and lifestyle intervention was 30 (8) and 9 (10) % (p

  4. High activity enables life on a high-sugar diet : blood glucose regulation in nectar-feeding bats

    NARCIS (Netherlands)

    Kelm, Detlev H; Simon, Ralph; Kuhlow, Doreen; Voigt, Christian C; Ristow, Michael

    2011-01-01

    High blood glucose levels caused by excessive sugar consumption are detrimental to mammalian health and life expectancy. Despite consuming vast quantities of sugar-rich floral nectar, nectar-feeding bats are long-lived, provoking the question of how they regulate blood glucose. We investigated blood

  5. Sesame and flaxseed oil: nutritional quality and effects on serum lipids and glucose in rats

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Avellaneda Guimarães

    2013-03-01

    Full Text Available This study evaluated the nutritional value of sesame and flaxseed oils and their effects on the lipid and glucose profile of rats fed diets containing different fat combinations. Fatty acid composition, refractive index, and iodine and saponification values were analyzed to characterize the oils. In the biological assay, Wistar rats were fed different diets, whose fat composition consisted of varying combinations of flaxseed oil, sesame oil, and animal fat. The primary constituents of the sesame oil were oleic (28.6%, linoleic (28.4%, and lauric acid (14.6%; for the flaxseed oil they were alpha-linolenic (39.90%, oleic (17.97% and linoleic acid (12.25%. The iodine and saponification values of the oils were within the reference range. Rats fed flaxseed oil-based diets had the lowest serum cholesterol values, whereas rats fed diets with flaxseed oil + sesame oil + animal fat had the highest glucose levels. HDL levels decreased significantly with flaxseed oil. Sesame and flaxseed oils are sources of polyunsaturated fatty acids (PUFA, and the flaxseed oil-based diet had a hypocholesterolemic effect, whereas sesame oil showed oxidative stability since it contains high levels of monounsaturated and saturated fatty acids.

  6. Effect of sulfonylureas administered centrally on the blood glucose level in immobilization stress model.

    Science.gov (United States)

    Sharma, Naveen; Sim, Yun-Beom; Park, Soo-Hyun; Lim, Su-Min; Kim, Sung-Su; Jung, Jun-Sub; Hong, Jae-Seung; Suh, Hong-Won

    2015-05-01

    Sulfonylureas are widely used as an antidiabetic drug. In the present study, the effects of sulfonylurea administered supraspinally on immobilization stress-induced blood glucose level were studied in ICR mice. Mice were once enforced into immobilization stress for 30 min and returned to the cage. The blood glucose level was measured 30, 60, and 120 min after immobilization stress initiation. We found that intracerebroventricular (i.c.v.) injection with 30 µg of glyburide, glipizide, glimepiride or tolazamide attenuated the increased blood glucose level induced by immobilization stress. Immobilization stress causes an elevation of the blood corticosterone and insulin levels. Sulfonylureas pretreated i.c.v. caused a further elevation of the blood corticosterone level when mice were forced into the stress. In addition, sulfonylureas pretreated i.c.v. alone caused an elevation of the plasma insulin level. Furthermore, immobilization stress-induced insulin level was reduced by i.c.v. pretreated sulfonylureas. Our results suggest that lowering effect of sulfonylureas administered supraspinally against immobilization stress-induced increase of the blood glucose level appears to be primarily mediated via elevation of the plasma insulin level.

  7. Impact of Prolonged Blood Incubation and Extended Serum Storage at Room Temperature on the Human Serum Metabolome

    Directory of Open Access Journals (Sweden)

    Beate Kamlage

    2018-01-01

    Full Text Available Metabolomics is a powerful technology with broad applications in life science that, like other -omics approaches, requires high-quality samples to achieve reliable results and ensure reproducibility. Therefore, along with quality assurance, methods to assess sample quality regarding pre-analytical confounders are urgently needed. In this study, we analyzed the response of the human serum metabolome to pre-analytical variations comprising prolonged blood incubation and extended serum storage at room temperature by using gas chromatography-mass spectrometry (GC-MS and liquid chromatography-tandem mass spectrometry (LC-MS/MS -based metabolomics. We found that the prolonged incubation of blood results in a statistically significant 20% increase and 4% decrease of 225 tested serum metabolites. Extended serum storage affected 21% of the analyzed metabolites (14% increased, 7% decreased. Amino acids and nucleobases showed the highest percentage of changed metabolites in both confounding conditions, whereas lipids were remarkably stable. Interestingly, the amounts of taurine and O-phosphoethanolamine, which have both been discussed as biomarkers for various diseases, were 1.8- and 2.9-fold increased after 6 h of blood incubation. Since we found that both are more stable in ethylenediaminetetraacetic acid (EDTA blood, EDTA plasma should be the preferred metabolomics matrix.

  8. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Otsuka, Makoto; Ichiya, Yuici; Kuwabara, Yasuo

    1989-01-01

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author)

  9. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  10. Low Red Blood Cell Vitamin C Concentrations Induce Red Blood Cell Fragility: A Link to Diabetes Via Glucose, Glucose Transporters, and Dehydroascorbic Acid

    Directory of Open Access Journals (Sweden)

    Hongbin Tu

    2015-11-01

    Full Text Available Strategies to prevent diabetic microvascular angiopathy focus on the vascular endothelium. Because red blood cells (RBCs are less deformable in diabetes, we explored an original concept linking decreased RBC deformability to RBC ascorbate and hyperglycemia. We characterized ascorbate concentrations from human and mouse RBCs and plasma, and showed an inverse relationship between RBC ascorbate concentrations and deformability, measured by osmotic fragility. RBCs from ascorbate deficient mice were osmotically sensitive, appeared as spherocytes, and had decreased β-spectrin. These aberrancies reversed with ascorbate repletion in vivo. Under physiologic conditions, only ascorbate's oxidation product dehydroascorbic acid (DHA, a substrate for facilitated glucose transporters, was transported into mouse and human RBCs, with immediate intracellular reduction to ascorbate. In vitro, glucose inhibited entry of physiologic concentrations of dehydroascorbic acid into mouse and human RBCs. In vivo, plasma glucose concentrations in normal and diabetic mice and humans were inversely related to respective RBC ascorbate concentrations, as was osmotic fragility. Human RBC β-spectrin declined as diabetes worsened. Taken together, hyperglycemia in diabetes produced lower RBC ascorbate with increased RBC rigidity, a candidate to drive microvascular angiopathy. Because glucose transporter expression, DHA transport, and its inhibition by glucose differed for mouse versus human RBCs, human experimentation is indicated.

  11. Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zhencheng [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Fang Cheng, E-mail: fangpingchuan@163.co [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Wang Hongyan; He Jishan [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China)

    2009-12-30

    A disposable glucose test strip with an integrated sensing/diffusion-limiting layer was developed. A formulation containing filler, glucose oxidase and electronic mediator was screen-printed over two carbon electrodes to form an integrated sensing/diffusion-limiting layer. On rehydration, the integrated layer does not break up, but swells to form a gelled and three-dimensional meshy reaction zone on the surface of the underlying conductive elements in which reactants and mediator move freely, but interfering species such as red blood cells containing oxygenated hemoglobin are excluded. On the same time, the integrated layer maintains a rate of permeation of the analyte through it with a variation of less than 10% at temperatures ranging from 15 deg. C to 42 deg. C. This biosensor is substantially insensitive to interferents and essentially independent to relevant temperature, which provides a more reliable reading of actual blood glucose value in human whole blood.

  12. Self-care among patients enrolled in a self-monitoring blood glucose program

    Directory of Open Access Journals (Sweden)

    Vivian Saraiva Veras

    Full Text Available This cross-sectional study checks specific self-care activities of patients with diabetes mellitus enrolled in a self-monitoring blood glucose program from August to December 2012 in two Primary Health Care units in the interior of São Paulo, Brazil. The sample was composed of 74 female and male individuals, aged 18 years old or older. The Summary of Diabetes Self-Care Activities Questionnaire was used. It contains six dimensions: general diet, specific diet, physical activity, blood glucose monitoring, foot care, medication usage, plus three items about smoking. Eight out of the 15 self-care activities were within desirable levels, namely: healthy diet, not eating sweets, blood glucose testing and as frequently as recommended, drying between toes after washing feet, and taking medications (three items. The results enabled the identification of gaps in specific self-care activities among patients with diabetes mellitus.

  13. Smart point-of-care systems for molecular diagnostics based on nanotechnology: whole blood glucose analysis

    Science.gov (United States)

    Devadhasan, Jasmine P.; Kim, Sanghyo

    2015-07-01

    Complementary metal oxide semiconductor (CMOS) image sensors are received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) film chip was developed to carry out the enzyme kinetic reaction at various concentrations of blood glucose. In this technique, assay reagent was adsorbed onto amine functionalized silica (AFSiO2) nanoparticles in order to achieve glucose oxidation on the PET film chip. The AFSiO2 nanoparticles can immobilize the assay reagent with an electrostatic attraction and eased to develop the opaque platform which was technically suitable chip to analyze by the camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique. The photon number decreases with increasing glucose concentration. The simple sensing approach, utilizing enzyme immobilized AFSiO2 nanoparticle chip and assay detection method was developed for quantitative glucose measurement.

  14. [Effects of blood glucose control on glucose variability and clinical outcomes in patients with severe acute pancreatitis in intensive care unit].

    Science.gov (United States)

    Wu, Jing; Sun, Qiuhong; Yang, Hua

    2015-05-19

    To explore the effects of blood glucose control on glucose variability and clinical outcomes in patients with severe acute pancreatitis in intensive care unit (ICU). A total of 72 ICU patients with severe acute pancreatitis were recruited and divided randomly into observation and control groups (n = 36 each). Both groups were treated conventionally. And the observation group achieved stable blood glucose at 6.1-8.3 mmol/L with intensive glucose control. The length of ICU and hospital stays, ICU mortality rate, transit operative rate, concurrent infection rate, admission blood glucose, glycosylated hemoglobin, mean insulin dose, mean blood glucose, blood glucose value standard deviation (GLUSD), glycemic liability index (GLUGLI) and mean amplitude of glycemic excursion (GLUMAGE) of two groups were compared. At the same time, the relationship between blood glucose variability, ICU mortality rate and its predictive value were analyzed by correlation analysis and receiver operating characteristic curve (ROC). The lengths of ICU and hospital stays of observation group were all significantly less than those of the control group [(11.7 ± 9.9) vs (15.9 ± 8.02) days, (21.8 ± 10.8) vs (28.2 ± 12.7) days, P blood glucose value and GLUSD of observation group were significantly lower than those of control group [(7.4 ± 1.1) vs (9.6 ± 1.2), (1.8 ± 1.0) vs (2.5 ± 1.3) mmol/L]. The differences were statistically significant (P curve analysis showed that, AUC of GLUGLI was 0.748 and 95% CI 0.551-0.965 (P glucose control in patients with severe acute pancreatitis helps reduce the blood sugar fluctuations, lower the risks of infectious complications and promote the patient rehabilitation. And GLUGLI is positively correlated with ICU mortality rate. It has good predictive values.

  15. Effect of ionising radiation and sal of cadmium on the changes of concentrations glucose and cholesterol in serum of chickens

    International Nuclear Information System (INIS)

    Kafka, I.; Danova, D.; Kalenicova, Z.; Striskova, K.

    2008-01-01

    The present study investigated changes of concentrations glucose and cholesterol in the serum of broiler chickens exposed to single of whole-body dose of 3 Gy gamma rays and concentration of cadmium 6 mg · kg -1 live weight. Samples of our experiment was analyse on the 7, 14 and 21 day after irradiation. (authors)

  16. Blood plasma separation in ZnO nanoflowers-supported paper based microfluidic for glucose sensing

    Science.gov (United States)

    Muhimmah, Luthviyah Choirotul; Roekmono, Hadi, Harsono; Yuwono, Rio Akbar; Wahyuono, Ruri Agung

    2018-04-01

    Blood plasma separation is essential to analyze and quantify the bio-substances in the human blood and hence, allows for diagnosing various diseases. This paper presents the two layer paper-based microfluidic analytical devices coated with ZnO nanoflowers (ZnO NF-µPAD) for a rapid blood plasma separation and glucose sensing. Plasma separation in ZnO NF-µPAD was evaluated experimentally and numerically using computational fluid dynamics package for a flow over porous networks. Glucose detection was carried out using Fourier-transform infrared (FTIR) measurements. The glucose concentrations in the red blood samples investigated here vary in the range of 150 - 310 mg.dl-1. The plasma separation process on ZnO NF-μPAD requires 240 ± 93 s. The spectroscopic data reveals that the IR absorptions and Raman signals at the typical vibrational frequencies of glucose are increasing at higher glucose concentration. After subtraction from absorption background arising from ZnO NF and the paper, linearly increasing IR absorption (913 and 1349 cm-1) and Raman signals (1346 and 1461 cm-1) are observable with a relatively good sensitivity.

  17. Magnesium enhances exercise performance via increasing glucose availability in the blood, muscle, and brain during exercise.

    Directory of Open Access Journals (Sweden)

    Hsuan-Ying Chen

    Full Text Available Glucose mobilization and utilization in the periphery and central nervous system are important during exercise and are responsible for exercise efficacy. Magnesium (Mg is involved in energy production and plays a role in exercise performance. This study aimed to explore the effects of Mg on the dynamic changes in glucose and lactate levels in the muscle, blood and brain of exercising rats using a combination of auto-blood sampling and microdialysis. Sprague-Dawley rats were pretreated with saline or magnesium sulfate (MgSO4, 90 mg/kg, i.p. 30 min before treadmill exercise (20 m/min for 60 min. Our results indicated that the muscle, blood, and brain glucose levels immediately increased during exercise, and then gradually decreased to near basal levels in the recovery periods of both groups. These glucose levels were significantly enhanced to approximately two-fold (P<0.05 in the Mg group. Lactate levels in the muscle, blood, and brain rapidly and significantly increased in both groups during exercise, and brain lactate levels in the Mg group further elevated (P<0.05 than those in the control group during exercise. Lactate levels significantly decreased after exercise in both groups. In conclusion, Mg enhanced glucose availability in the peripheral and central systems, and increased lactate clearance in the muscle during exercise.

  18. Pseudohyperglycemia: Effects of Unwashed Hand after Fruit Peeling or Handling on Fingertips Blood Glucose Monitoring Results.

    Science.gov (United States)

    Olamoyegun, M A; Oloyede, T; Adewoye, O G; Abdulkarim, S O; Adeleke, A A

    2016-01-01

    Self-monitoring of blood glucose (SMBG) is an important component of management for diabetes mellitus (DM), especially in T1DM and T2DM patients who are on insulin therapy. Adequate blood glucose monitoring and prompt intervention are necessary to prevent blood glucose (BG) fluctuation and delay long-term diabetes complications. People with DM are advised to clean their hands before SMBG to remove any dirt or food residue that might affect the reading. The study tested the hypothesis that falsely elevated BG levels from fingertip occur after peeling or handling fruits in an unwashed hand. Fifty apparently healthy nondiabetes volunteers were enrolled. Capillary BG samples were collected from the fingertips after peeling or handling apple, orange, banana, watermelon, and pawpaw, followed by no hand washing for 1 h, cleaning the fingertip with alcohol swab once, five times, and washing hand thoroughly with tap water and drying. These samples were then analyzed with two different glucose meters. The mean BG values, measured from fingertip blood samples after peeling, and handling any of the fruits followed by no hand washing were significantly high, even after cleaning fingertip with a swab of alcohol once. However, there were no significant difference in BG levels measured after peeling and handling fruits followed by hand washing and the level of BG before peeling and handling fruits. Handling of peeled fruits with no hand washing with tap water is associated with overestimation of capillary BG (Pseudohyperglycemia) monitored with glucose meters.

  19. Effect of GABA receptor agonists or antagonists injected spinally on the blood glucose level in mice.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kang, Yu-Jung; Kim, Sung-Su; Kim, Chea-Ha; Kim, Su-Jin; Jung, Jun-Sub; Ryu, Ohk-Hyun; Choi, Moon-Gi; Suh, Hong-Won

    2013-05-01

    The possible roles of gamma-amino butyric acid (GABA) receptors located in the spinal cord for the regulation of the blood glucose level were studied in ICR mice. We found in the present study that intrathecal (i.t.) injection with baclofen (a GABAB receptor agonist; 1-10 μg/5 μl) or bicuculline (a GABAA receptor antagonist; 1-10 μg/5 μl) caused an elevation of the blood glucose level in a dose-dependent manner. The hyperglycemic effect induced by baclofen was more pronounced than that induced by bicuculline. However, muscimol (a GABAA receptor agonist; 1-5 μg/5 μl) or phaclofen (a GABAB receptor antagonist; 5-10 μg/5 μl) administered i.t. did not affect the blood glucose level. Baclofen-induced elevation of the blood glucose was dose-dependently attenuated by phaclofen. Furthermore, i.t. pretreatment with pertussis toxin (PTX; 0.05 or 0.1 μg/5 μl) for 6 days dose-dependently reduced the hyperglycemic effect induced by baclofen. Our results suggest that GABAB receptors located in the spinal cord play important roles for the elevation of the blood glucose level. Spinally located PTX-sensitive G-proteins appear to be involved in hyperglycemic effect induced by baclofen. Furthermore, inactivation of GABAA receptors located in the spinal cord appears to be responsible for tonic up-regulation of the blood glucose level.

  20. Carbohydrate ingestion before and during soccer match play and blood glucose and lactate concentrations.

    Science.gov (United States)

    Russell, Mark; Benton, David; Kingsley, Michael

    2014-01-01

    The ingestion of carbohydrate (CHO) before and during exercise and at halftime is commonly recommended to soccer players for maintaining blood glucose concentrations throughout match play. However, an exercise-induced rebound glycemic response has been observed in the early stages of the second half of simulated soccer-specific exercise when CHO-electrolyte beverages were consumed regularly. Therefore, the metabolic effects of CHO beverage consumption throughout soccer match play remain unclear. To investigate the blood glucose and blood lactate responses to CHOs ingested before and during soccer match play. Crossover study. Applied research study. Ten male outfield academy soccer players (age = 15.6 ± 0.2 years, height = 1.74 ± 0.02 m, mass = 65.3 ± 1.9 kg, estimated maximal oxygen consumption = 58.4 ± 0.8 mL·kg(-1)·min(-1)). Players received a 6% CHO-electrolyte solution or an electrolyte (placebo) solution 2 hours before kickoff, before each half (within 10 minutes), and every 15 minutes throughout exercise. Blood samples were obtained at rest, every 15 minutes during the match (first half: 0-15, 15-30, and 30-45 minutes; second half: 45-60, 60-75, and 75-90 minutes) and 10 minutes into the halftime break. Metabolic responses (blood glucose and blood lactate concentrations) and markers of exercise intensity (heart rate) were recorded. Supplementation influenced the blood glucose response to exercise (time × treatment interaction effect: P ≤ .05), such that glucose concentrations were higher at 30 to 45 minutes in the CHO than in the placebo condition. However, in the second half, blood glucose concentrations were similar between conditions because of transient reductions from peak values occurring in both trials at halftime. Blood lactate concentrations were elevated above those at rest in the first 15 minutes of exercise (time-of-sample effect: P interaction effect: P = .49). Ingestion of a 6% CHO-electrolyte beverage before and during soccer match

  1. Correlation of the association of serum lactate, random blood sugar ...

    African Journals Online (AJOL)

    2015-09-21

    Sep 21, 2015 ... reversal of the physiologic and metabolic changes associated with consequent .... reduction in serum lactate levels, as well as RBG levels with a transient ... in our environment considering the cost and logistics in developing ...

  2. Effect of Probiotics on Serum Biochemical and Blood Constituents in ...

    African Journals Online (AJOL)

    Conclusion: Salmonella challenge affects serum albumin, globulin and GOT enzyme. The results obtained suggest that the probiotic, Toyocerin, mitigates the negative effects of Salmonella challenge. Keywords: Bacillus subtilis PB6, Bacillus Cereus var. toyoi, Probiotics, Liver enzymes, Hematology,. Salmonella enterica.

  3. No relationship between cerebral blood flow velocity and cerebrovascular reserve capacity and contemporaneously measured glucose and insulin concentrations in diabetes mellitus

    NARCIS (Netherlands)

    Fülesdi, B.; Limburg, M.; Bereczki, D.; Molnár, C.; Michels, R. P.; Leányvári, Z.; Csiba, L.

    1999-01-01

    Blood glucose and insulin concentrations have been reported to influence cerebral hemodynamics. We studied the relationship between actual blood glucose and insulin concentrations and resting cerebral blood flow velocity in the middle cerebral artery and cerebrovascular reserve capacity after

  4. [IMPACT OF PERIOPERATIVE AVERAGE BLOOD-GLUCOSE LEVEL ON PROGNOSIS OF PATIENTS WITH HIP FRACTURE AND DIABETES MELLITUS].

    Science.gov (United States)

    Wang, Guoqi; Long, Anhua; Zhang, Lihai; Zhang, Hao; Yin, Peng; Tang, Peifu

    2014-07-01

    To explore the impact of perioperative average blood-glucose level on the prognosis of patients with hip fracture and diabetes mellitus. A retrospective analysis was made on the clinical data of 244 patients with hip fracture and diabetes mellitus who accorded with the inclusion criteria between September 2009 and September 2012. Of 244 patients, 125 patients with poorly controlled fasting blood-glucose (average fasting blood-glucose level > 7.8 mmol/L) were assigned in group A, and 119 patients with well controlled fasting blood-glucose (average fasting blood-glucose level ≤ 7.8 mmol/L) were assigned in group B according to "China guideline for type 2 diabetes" criteria. There was no significant difference in gender, age, disease duration of diabetes mellitus, serum albumin, fracture type and disease duration, surgical procedure, anaesthesia, and complications between 2 groups (P > 0.05). Group A had a higher hemoglobin level and fewer patients who can do some outdoor activities than group B (t = -2.353, P = 0.020; χ2 = 4.333, P = 0.037). The hospitalization time, days to await surgery, stitch removal time, the postoperative complication rate, the mortality at 1 month and 1 year after operation, and ambulatory ability at 1 year after operation were compared between the 2 groups. A total of 223 patients (114 in group A and 109 in group B) were followed up 12-15 months (mean, 13.5 months). The days to await surgery of group A were significantly more than those of group B (t = -2.743, P=0.007), but no significant difference was found in hospitalization time and stitch removal time between 2 groups (P > 0.05). The postoperative complication rate of group A (19.2%, 24/125) was significantly higher than that of group B (8.4%, 10/119) (χ2 =5.926, P = 0.015). Group A had a higher mortality at 1 month after operation than group B (6.1% vs. 0) (χ2 = 5.038, P = 0.025), but no significant difference was shown at 1 year after operation between groups A and B (8.8% vs. 4

  5. Perceptions of Caribbean type 2 diabetes patients on self-monitoring of blood glucose

    DEFF Research Database (Denmark)

    Ezenwaka, C. E.; Olukoga, A.; Onuoha, P.

    2012-01-01

    Context: The views of type 2 diabetes (T2DM) patients have not been considered in the debate on the role of self-monitoring of blood glucose (SMBG) in the management of T2DM. Objective: To assess the views of T2DM patients on SMBG. Methods: Two previously trained research assistants used a struct......Context: The views of type 2 diabetes (T2DM) patients have not been considered in the debate on the role of self-monitoring of blood glucose (SMBG) in the management of T2DM. Objective: To assess the views of T2DM patients on SMBG. Methods: Two previously trained research assistants used...

  6. Increasing synthetic serum substitute (SSS) concentrations in P1 glucose/phosphate-free medium improves implantation rate: a comparative study.

    Science.gov (United States)

    Ben-Yosef, D; Yovel, I; Schwartz, T; Azem, F; Lessing, J B; Amit, A

    2001-11-01

    To assess the comparative efficacy of IVF medium (MediCult, with 5.2 mM glucose) and a glucose/phosphate-free medium, P1 (Irvine Scientific), and to investigate the influence of increasing the serum supplementation (synthetic serum substitute; SSS; Irvine Scientific) to P1 on embryo development and implantation. Patients were randomly assigned to IVF medium (Group 1, cycles n = 172) or P1 supplemented with 10% SSS (Group 2, cycles n = 229) according to the medium scheduled for use on the day of oocyte retrieval. Another 555 IVF consequent cycles (Group 3) were performed using increased SSS concentrations (20%) in P1 medium. In this large series of IVF cycles, we herein demonstrate that significantly higher pregnancy and implantation rates were found when embryos were cultured in glucose/phosphate-free medium P1 supplemented with 20% SSS compared to supplementation with the lower SSS concentration and with IVF medium.

  7. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  8. Evaluation of the Blood-Glucose Reducing Effects of Aqueous ...

    African Journals Online (AJOL)

    Methods: All the aqueous extracts of (Caraway) CA, (Coriander) CO, (Cumin) CU, (Dill) DI and (Fennel) FE were administered at dose levels of 300 mg/kg body weight orally to different groups each containing 5 animals. A control group was also maintained simultaneously and received distilled water orally.Blood samples ...

  9. Comparison of the clinical information provided by the FreeStyle Navigator continuous interstitial glucose monitor versus traditional blood glucose readings.

    Science.gov (United States)

    McGarraugh, Geoffrey V; Clarke, William L; Kovatchev, Boris P

    2010-05-01

    The purpose of the analysis was to compare the clinical utility of data from traditional self-monitoring of blood glucose (SMBG) to that of continuous glucose monitoring (CGM). A clinical study of the clinical accuracy of the FreeStyle Navigator CGM System (Abbott Diabetes Care, Alameda, CA), which includes SMBG capabilities, was conducted by comparison to the YSI blood glucose analyzer (YSI Inc., Yellow Springs, OH) using 58 subjects with type 1 diabetes. The Continuous Glucose-Error Grid Analysis (CG-EGA) was used as the analytical tool. Using CG-EGA, the "clinically accurate," "benign errors," and "clinical errors" were 86.8%, 8.7%, and 4.5% for SMBG and 92.7%, 3.7%, and 3.6% for CGM, respectively. If blood glucose is viewed as a process in time, SMBG would provide accurate information about this process 86.8% of the time, whereas CGM would provide accurate information about this process 92.7% of the time (P glucose values than CGM, control of blood glucose involves a system in flux, and CGM provides more detailed insight into the dynamics of that system. In the normal and elevated glucose ranges, the additional information about the direction and rate of glucose change provided by the FreeStyle Navigator CGM System increases the ability to make correct clinical decisions when compared to episodic SMBG tests.

  10. Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen

    NARCIS (Netherlands)

    Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C

    The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum

  11. The influence of metronidazole on free thymidine content of blood serum of irradiated mice

    International Nuclear Information System (INIS)

    Konov, A.V.; Ryabchenko, N.I.

    1986-01-01

    The influence of a radiosensitizer, metronidazole, on the free thymidine content of blood serum of irradiated mice was studied in aerobic and hypoxic conditions. A heated metronidazole solution (1 mg/g) was administered intraperitoneally 30 min before irradiation of animals with a dose of 3 Gy. Thymidine concentration in blood serum was determined by the radioimmunological technique. The influence of metronidazole on the level of thymidinemia was only noted in the animals exposed under hypoxic conditions

  12. The Great Recession worsened blood pressure and blood glucose levels in American adults.

    Science.gov (United States)

    Seeman, Teresa; Thomas, Duncan; Merkin, Sharon Stein; Moore, Kari; Watson, Karol; Karlamangla, Arun

    2018-03-27

    Longitudinal, individual-specific data from the Multi-Ethnic Study of Atherosclerosis (MESA) provide support for the hypothesis that the 2008 to 2010 Great Recession (GR) negatively impacted the health of US adults. Results further advance understanding of the relationship by ( i ) illuminating hypothesized greater negative impacts in population subgroups exposed to more severe impacts of the GR and ( ii ) explicitly controlling for confounding by individual differences in age-related changes in health over time. Analyses overcome limitations of prior work by ( i ) employing individual-level data that avoid concerns about ecological fallacy associated with prior reliance on group-level data, ( ii ) using four waves of data before the GR to estimate and control for underlying individual-level age-related trends, ( iii ) focusing on objective, temporally appropriate health outcomes rather than mortality, and ( iv ) leveraging a diverse cohort to investigate subgroup differences in the GR's impact. Innovative individual fixed-effects modeling controlling for individual-level age-related trajectories yielded substantively important insights: ( i ) significant elevations post-GR for blood pressure and fasting glucose, especially among those on medication pre-GR, and ( ii ) reductions in prevalence and intensity of medication use post-GR. Important differences in the effects of the GR are seen across subgroups, with larger effects among younger adults (who are likely still in the labor force) and older homeowners (whose declining home wealth likely reduced financial security, with less scope for recouping losses during their lifetime); least affected were older adults without a college degree (whose greater reliance on Medicare and Social Security likely provided more protection from the recession).

  13. PENGARUH DIET KACANG MERAH TERHADAP KADAR GULA DARAH TIKUS DIABETIK INDUKSI ALLOXAN [Effect of Red Bean Diet on Blood Glucose Concentration of Alloxan-Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Y. Marsono 1

    2003-04-01

    Full Text Available Hypoglycemic response of red bean were evaluated in alloxan-induced diabetic rats. The objective of this research was to evaluate the effect of red bean (Vigna umbellata diet compare with soy bean diet on blood glucose concentration in alloxan-induced diabetic rats.Thirty male Sprague-Dawley (SD rats (250-300 g were diabetic induced by alloxan injection (80 mg/kg of body weight by intra muscular injection. They were divided into three groups of ten rats. They were fed (1 Standard diet (STD, (2 Red bean diet (KM, and (3 Soy bean diet (KD for 28 days. Concentration of serum glucose were determined before injection (0 day,after injection (day 17th and every sweek during diet intervention (day 24,31,38 and 45thIt was found that alloxan injection increased serum glucose concentration of STD, KM, and KD rats. After 28 days intervention, red bean decreased the serum glucose concentration from 217, 87 mg/dL to 57,70 mg/dL (69 % in KM groups and from 218,94 mg/dL to 76,82 mg/dL (65 % in KD groups, but standard diet (STD were decreased less than both of KM and KD diet.

  14. The Effect of Trans-Chalcone on Amylase Activity, Blood Glucose and Lipid Levels in Diabetic and Non Diabetic Rats

    Directory of Open Access Journals (Sweden)

    M Najafian

    2011-04-01

    Full Text Available Introduction & Objective: Alpha amylase is the most important decomposing enzyme in starch. Digestion and absorption of starch in the intestine can be prevented and also the blood sugar levels can be controlled by restrain and control of alpha amylase. The aim of this study was to evaluate the effect of trans-chalcone on amylase activity, blood glucose and lipid levels in diabetic and non diabetic rats. Materials & Methods: This experimental study was conducted in 1388 at Tehran University of Medical Sciences. Sixty rats were randomly divided to ten equal groups: non diabetic control, diabetic control, four non diabetic experiments and four diabetic experiments. Control groups received grape seed oil and experimental groups received 2, 8,16 and 32 mg/kg of body weight in a period of 24 days with a gastric cannula. Blood sugar, every two days, serum insulin levels in days 0,12, and 24 and at the end of the experiment, lipoproteins and alpha amylase activity were measured.The data were analyzed by one way analysis of variance, ANOVA, followed by Turkey,s test with SPSS soft ware . Results: On average Chalcone reduced 25.5% of blood sugar in normal and diabetic rats. IT also decreased the serum insulin level. On average, chalcone decreased 34.9% of alpha amylase activity in normal and diabetic rats. Following disturbances in lipids metabolism caused by diabetes, this drug improved lipoproteins metabolism and reduced water, food and urine volume. Conclusion: This study shows that trans-Chalcone reduces blood sugar and body weight via inhibition of alpha amylas. Moreover, improvement of lipoprotein metabolism may happen via the inhibitory effect of this drug on hydroxyl methyl glutaryl -COA reductase and phosphodiesterase.

  15. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  16. Precision and accuracy of blood glucose measurements using three different instruments.

    Science.gov (United States)

    Nowotny, B; Nowotny, P J; Strassburger, K; Roden, M

    2012-02-01

    Assessment of insulin sensitivity by dynamic metabolic tests such as the hyperinsulinemic euglycemic clamp critically relies on the reproducible and fast measurement of blood glucose concentrations. Although various instruments have been developed over the last decades, little is known as to the accuracy and comparability. We therefore compared the best new instrument with the former gold standard instruments to measure glucose concentrations in metabolic tests. Fasting blood samples of 15 diabetic and 10 healthy subjects were collected into sodium-fluoride tubes, spiked with glucose (0, 2.8, 6.9 and 11.1 mmol/l) and measured either as whole blood (range 3.3-26.3 mmol/l) or following centrifugation as plasma (range 3.9-32.0 mmol/l). Plasma samples were analyzed in the YSI-2300 STAT plus (YSI), EKF Biosen C-Line (EKF) and the reference method, Beckman Glucose analyzer-II (BMG), whole blood samples in EKF instruments with YSI as reference method. The average deviation of the EKF from the reference, BMG, was 3.0 ± 3.5% without any concentration-dependent variability. Glucose measurements by YSI were in good agreement with that by BMG (plasma) and EKF (plasma and whole blood) up to concentrations of 13.13 mmol/l (0.5 ± 3.7%), but deviation increased to -6.2 ± 3.8% at higher concentrations. Precision (n = 6) was ±2.2% (YSI), ±3.9% (EKF) and ±5.2% (BMG). The EKF instrument is comparable regarding accuracy and precision to the reference method BMG and can be used in metabolic tests, while the YSI showed a systematic shift at higher glucose concentrations. Based on these results we decided to replace BMG with EKF instrument in metabolic tests. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  17. Effects of blood glucose on delay discounting, food intake and counterregulation in lean and obese men.

    Science.gov (United States)

    Klement, Johanna; Kubera, Britta; Eggeling, Jonas; Rädel, Christin; Wagner, Christin; Park, Soyoung Q; Peters, Achim

    2018-03-01

    Delay discounting as a measure of impulsivity has been shown to be higher in obesity with an association of increased food intake. Moreover, obese humans showed a higher wanting for high-calorie food than lean men when blood glucose concentrations were low. First studies linking blood glucose levels to delay discounting yielded mixed results. We hypothesized that obese people - in comparison to lean men - have a relative lack of energy, especially when blood glucose levels are low, that results in higher levels of delay discounting, food intake and hormonal counterregulation. We investigated 20 lean and 20 obese healthy young men in a single-blind balanced cross-over design. With a standardized glucose clamp technique, subjects underwent a hypoglycemic state in one condition and a euglycemic state in the control condition. Regularly, blood was sampled for assessment of hormonal status, and questionnaires were filled out to assess delay discounting and symptom awareness. After normalizing blood glucose concentrations, subjects were free to eat from a standardized test buffet, followed by a snack test. Delay discounting was higher in obese than in lean men throughout experiments (p  0.1). Furthermore, the discounting performance did not correlate with food intake from the test buffet or snack test (p > 0.3). As a response to hypoglycemia, hormonal counterregulation was pronounced in both weight groups (p  0.5). Our data suggest that augmented delay discounting is a robust feature in obesity that is not linked to glucose levels or actual food intake. With our systematically controlled approach, combining performance in delay discounting with regard to distinct blood glucose levels, different weight groups, counterregulatory behavior and food intake, our results imply that delay discounting is not susceptible to fluctuations of blood glucose and do not support the assumption that a low body's energy content leads to increased impulsivity. Further

  18. Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.

    Science.gov (United States)

    Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno

    2016-06-01

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Comparison of serum leptin, glucose, total cholesterol and total protein levels in fertile and repeat breeder cows

    Directory of Open Access Journals (Sweden)

    Saime Guzel

    2014-12-01

    Full Text Available In the present study we measured serum glucose, leptin, total cholesterol and total protein concentrations in repeat breeder cows and compared them with fertile cows. For this aim, 20 repeat breeder cows and 20 fertile cows were used as material. Repeat breeder cows were found to have lower levels of leptin and glucose as compared with fertile ones. No significant differences in total cholesterol and total protein levels were observed between the two groups. No significant correlation of leptin with glucose, total cholesterol and total protein was observed in fertile and repeat breeder cows. Low concentrations of glucose and leptin can have some effects on reproductive problems as repeat breeder and help to understand potential mechanisms impairing fertility in repeat breeder cows.

  20. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  1. Adolescents with clinical type 1 diabetes display reduced red blood cell glucose transporter isoform 1 (GLUT1).

    Science.gov (United States)

    Garg, Meena; Thamotharan, Manikkavasagar; Becker, Dorothy J; Devaskar, Sherin U

    2014-11-01

    Type 1 diabetic (T1D) adolescent children on insulin therapy suffer episodes of both hyper- and hypoglycemic episodes. Glucose transporter isoform GLUT1 expressed in blood-brain barrier (BBB) and red blood cells (RBC) compensates for perturbed circulating glucose toward protecting the supply to brain and RBCs. We hypothesized that RBC-GLUT1 concentration, as a surrogate for BBB-GLUT1, is altered in T1D children. To test this hypothesis, we measured RBC-GLUT1 by enzyme-linked immunosorbent assay (ELISA) in T1D children (n = 72; mean age 15.3 ± 0.2 yr) and control children (CON; n = 11; mean age 15.6 ± 0.9 yr) after 12 h of euglycemia and during a hyperinsulinemic-hypoglycemic clamp with a nadir blood glucose of ~3.3 mmol/L for 90 min (clamp I) or ~3 mmol/L for 45 min (clamp II). Reduced baseline RBC-GLUT1 was observed in T1D (2.4 ± 0.17 ng/ng membrane protein); vs. CON (4.2 ± 0.61 ng/ng protein) (p < 0.0001). Additionally, baseline RBC-GLUT1 in T1D negatively correlated with hemoglobin A1c (HbA1c) (R = -0.23, p < 0.05) but not in CON (R = 0.06, p < 0.9). Acute decline in serum glucose to 3.3 mmol/L (90 min) or 3 mmol/L (45 min) did not change baseline RBC-GLUT1 in T1D or CON children. We conclude that reduced RBC-GLUT1 encountered in T1D, with no ability to compensate by increasing during acute hypoglycemia over the durations examined, may demonstrate a vulnerability of impaired RBC glucose transport (serving as a surrogate for BBB), especially in those with the worst control. We speculate that this may contribute to the perturbed cognition seen in T1D adolescents. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Successful microsurgical lip replantation: Monitoring venous congestion by blood glucose measurements in the replanted lip

    OpenAIRE

    Kazufumi Tachi; Masanori Mori; Reiko Tsukuura; Rintaro Hirai

    2018-01-01

    Replantation of an amputated lip using microvascular anastomosis is the best option for restoration of the defect. However, the amputated region often lacks veins with appropriate diameters for microvascular anastomoses and typically necessitates both postoperative exsanguination using medicinal leeches and a blood transfusion. We present a case of the successful replantation of an avulsed lip in which postoperative congestion was evaluated objectively by measuring blood glucose levels in the...

  3. Interaction of molybdenum with blood serum proteins in vitro

    International Nuclear Information System (INIS)

    Bibr, B.; Kselikova, M.; Lener, J.

    1985-01-01

    The interaction of pentavalent and hexavalent 99 Mo compounds with rat and human serum was monitored in vitro by paper electrophoresis after incubation for one hour at 37 0 C. Hexavalent 99 Mo is not capable of interaction and, via sulfur ligands, forms unstable and unspecific bonds to the whole spectrum of serum proteins, in particular to albumin. Pentavalent 99 Mo binds strongly to alpha-2-macroglobulin in a ratio of 2 : 1; according to the nature of the ligand, it forms somewhat unstable bonds to albumin, beta-1-globulin and gamma-2-globulin. (author)

  4. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy.

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2012-01-31

    BACKGROUND: To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. METHODS: Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. RESULTS: Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. CONCLUSION: During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  5. Performance of a new test strip for freestyle blood glucose monitoring systems.

    Science.gov (United States)

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  6. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2011-02-04

    Abstract Background To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. Methods Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. Results Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. Conclusion During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  7. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  8. Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization

    International Nuclear Information System (INIS)

    Wróbel, M.S.

    2016-01-01

    The number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its perforation. This paper presents the limitations and possibilities of non-invasive blood glucose monitoring with Raman spectroscopy. Especially focusing on the possibilities for device miniaturization. Such device incorporates a Raman spectrometer, a fiber-optical probe, and a computing device (microcontroller, smartphone, etc.) which calculates the glucose concentration using specialized algorithms. Simplification of device design, as well as turbidity correction technique and a new proposed method of synchronized detection are described

  9. Glucose-6-phosphate dehydrogenase activity decreases during storage of leukoreduced red blood cells

    NARCIS (Netherlands)

    Peters, Anna L.; van Bruggen, Robin; de Korte, Dirk; van Noorden, Cornelis J. F.; Vlaar, Alexander P. J.

    2016-01-01

    During storage, the activity of the red blood cell (RBC) antioxidant system decreases. Glucose-6-phosphate dehydrogenase (G6PD) is essential for protection against oxidative stress by producing NADPH. G6PD function of RBC transfusion products is reported to remain stable during storage, but activity

  10. Effect of miglitol (BAY m-1099) on fasting blood glucose in type 2 diabetes mellitus

    NARCIS (Netherlands)

    Sels, J P; Kingma, P J; Wolffenbuttel, B H; Menheere, P P; Branolte, J H; Nieuwenhuijzen Kruseman, A C

    BACKGROUND: In type 2 diabetes mellitus, fasting blood glucose values are increased due to increased glycogenolysis and gluconeogenesis. As miglitol (BAY m-1099), an absorbable alpha-glucosidase inhibitor, can inhibit glycogenolysis, we investigated whether 200 mg miglitol ingested at bedtime could

  11. Change of blood glucose level and its possible mechanism in patients with cerebral stroke

    International Nuclear Information System (INIS)

    Chen Weizhen; Zhang Yong; Zhang Zikang; Mo Congjian

    2003-01-01

    To study the mechanism of the change of blood glucose levels in patients with cerebral stroke, the levels of blood glucose, cortisol, glucogen, insulin, growth hormone, triiodothyronine (T 3 ), thyroxine (T 4 ) and adrenocorticotropic hormone (ACTH) were dynamically measured in 90 patients with cerebral stroke. The circumstances of brain middle line movement, lateral ventricle oppression and entrance brain ventricle of burst hematoma of the patients were examines by CT scan. The total incidence of hyperglycemia in the patients was 42.22%. The blood glucose level was positively related to the cortisol and glucogen levels, and negatively related to the T 3 level. The changed level of blood glucose and its related hormones both returned to normal range in 10 days. Both the ACTH level and the rate of cerebral pathological change in hyperglycemia group were significantly higher than that in normoglycemia and control groups. The rate of cerebral pathological change in elevated ACTH level group was higher than that in normal ACTH level group. The mechanism of hyperglycemia in the patients with cerebral stroke might be related to the stimulation of the hypothalamus, which may induce the discharge of ACTH and glucagon releasing factor, and to that the level of cortisol and glucagon increased, the level of T 3 decreased

  12. Bihormonal model predictive control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tarnik, Marian; Murgas, Jan

    2014-01-01

    In this paper we present a bihormonal control system that controls blood glucose in people with type 1 diabetes (T1D). We use insulin together with glucagon to mitigate the negative effects of hyper- and hypoglycemia. The system consists of a Kalman filter, a micro-bolus insulin and glucagon...

  13. Examining the causal association of fasting glucose with blood pressure in healthy children and adolescents

    DEFF Research Database (Denmark)

    Goharian, T S; Andersen, Lars Bo; Franks, P W

    2015-01-01

    The aim of the study was to determine whether genetically raised fasting glucose (FG) levels are associated with blood pressure (BP) in healthy children and adolescents. We used 11 common genetic variants of FG discovered in genome-wide association studies (GWAS), including the rs560887 single...

  14. [Evaluation of hearing loss parameters in workers and its relationship with fasting blood glucose levels].

    Science.gov (United States)

    Vicente-Herrero, M Teofila; Lladosa Marco, Silvia; Ramírez-Iñiguez de La Torre, M Victoria; Terradillos-García, M Jesús; López-González, Ángel Arturo

    2014-05-01

    Hearing loss due to noise is considered within the prevention plans of the most common occupational diseases. In addition to evaluation of working conditions, other personal factors increasing the risk of hypoacusis, such as diabetes, should be taken into account. To explore hearing loss in the workplace and its relationship to impaired fasting baseline blood glucose levels. An observational, cross-sectional study enrolling 1636 workers from service companies was conducted. Full audiometric evaluation was performed at different frequencies: high frequency (HF), early loss index (ELI), speech average loss (SAL), and monaural and binaural loss. Results were categorized by baseline blood glucose levels: G1 (125mg/dl). Based on both HF and ELI, 11% of workers had clear indication of deafness. Women with G3 levels showed significant differences in the results of HF and ELI indexes as compared to the G1 group (P=.038 and .046, respectively). A positive association was found between hearing loss and G3 blood glucose levels in HF (OR: .338; p=.002), ELI (OR: .407; p=.007), and the monaural test in the left ear (OR: 4.77×10-5; p=.006). Despite the methodological limitations of this study, there is evidence for an increased risk of high frequency hearing loss in workers with high baseline blood glucose levels. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  15. Aronia juice suppresses the elevation of postprandial blood glucose levels in adult healthy Japanese

    Directory of Open Access Journals (Sweden)

    Takuya Yamane

    2017-04-01

    Full Text Available Aronia has various functions toward human health, including the beneficial effect on hypertension, hyperglycemia and hyperlipidemia. Recently, we identified cyanidin-3,5-O-diglucoside as DPP IV inhibitor from Aronia juice. We also found its beneficial effect on hyperglycemia in KKAy mice fed aronia juice. In this study, to examine the effect of aronia juice on postprandial blood glucose levels in Japanese, we performed an oral meal tolerance test (OMTT. We found that postprandial blood glucose levels were reduced in aronia juice-administered adult healthy Japanese. We also found that there was no difference of reduction levels of postprandial blood glucose between male and female. We also found that activities of dipeptidyl peptidase IV (DPP IV, α-glucosidase and angiotensin-converting enzyme (ACE were reduced by aronia juice. These results suggest that aronia juice suppresses the elevation of postprandial blood glucose levels through inhibition of these enzyme activities and may be useful for prevention of metabolic diseases in adult healthy Japanese.

  16. Comparison electrical stimulation and passive stretching for blood glucose control type 2 diabetes mellitus patients

    Science.gov (United States)

    Arsianti, Rika Wahyuni; Parman, Dewy Haryanti; Lesmana, Hendy

    2018-04-01

    Physical exercise is one of the cornerstones for management and treatment type 2 diabetes mellitus. But not all people are able to perform physical exercise because of their physical limitation condition. The strategy for those people in this study is electrical stimulation and passive stretching. The aim of this study is to find out the effect of electrical stimulation and passive stretching to lowering blood glucose level. 20 subjects is divided into electrical stimulation and passive stretching group. The provision of electrical stimulation on lower extremities muscles for 30 minutes for electrical stimulation group (N=10). And other underwent passive stretching for 30 minutes (N=10). The result shows that blood glucose level is decrease from 192.9 ± 10.7087 mg/dL to 165.3 ± 10.527 mg/dL for electrical stimulation intervention group while for the passive stretching group the blood glucose decrease from 153 ± 12.468 mg/dL to 136.1 ± 12.346 mg/dL. Both electrical stimulation and passive stretching are effective to lowering blood glucose level and can be proposed for those people restricted to perform exercise.

  17. Comprehensive Experiment--Clinical Biochemistry: Determination of Blood Glucose and Triglycerides in Normal and Diabetic Rats

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a…

  18. Effect of self-monitoring of blood glucose on glycaemic outcome ...

    African Journals Online (AJOL)

    Background: Diabetes mellitus is a chronic metabolic disorder which leads to complications especially when not properly managed. The role of self-monitoring of blood glucose (SMBG) in type 2 diabetic patients using oral hypoglycaemic agents has been a source of controversy. Objective: The objective was to study the ...

  19. Effect of liraglutide on myocardial glucose uptake and blood flow in stable chronic heart failure patients

    DEFF Research Database (Denmark)

    Nielsen, Roni; Jorsal, Anders; Iversen, Peter

    2017-01-01

    BACKGROUND: The glucagon-like peptide-1 analog liraglutide increases heart rate and may be associated with more cardiac events in chronic heart failure (CHF) patients. We studied whether this could be ascribed to effects on myocardial glucose uptake (MGU), myocardial blood flow (MBF) and MBF rese...

  20. Galanin regulates blood glucose level in the zebrafish: a morphological and functional study.

    Science.gov (United States)

    Podlasz, P; Jakimiuk, A; Chmielewska-Krzesinska, M; Kasica, N; Nowik, N; Kaleczyc, J

    2016-01-01

    The present study has demonstrated the galaninergic innervation of the endocrine pancreas including sources of the galaninergic nerve fibers, and the influence of galanin receptor agonists on blood glucose level in the zebrafish. For the first time, a very abundant galaninergic innervation of the endocrine pancreas during development is shown, from the second day post-fertilization to adulthood. The fibers originated from ganglia consisting of galanin-IR, non-adrenergic (non-sensory) neurons located rostrally to the pancreatic tissue. The ganglia were found on the dorsal side of the initial part of the anterior intestinal segment, close to the intestinal branch of the vagus nerve. The galanin-IR neurons did not show immunoreactivity for applied antibodies against tyrosine hydroxylase, choline acetyltransferase, and vesicular acetylcholine transporter. Intraperitoneal injections of galanin analog NAX 5055 resulted in a statistically significant increase in the blood glucose level. Injections of another galanin receptor agonist, galnon, also caused a rise in blood glucose level; however, it was not statistically significant. The present findings suggest that, like in mammals, in the zebrafish galanin is involved in the regulation of blood glucose level. However, further studies are needed to elucidate the exact mechanism of the galanin action.

  1. Pharmacokinetics and pharmacodynamics of various glucagon dosages at different blood glucose levels

    NARCIS (Netherlands)

    Blauw, H.; Wendl, I.; DeVries, J. H.; Heise, T.; Jax, T.

    2016-01-01

    To evaluate the pharmacokinetics and pharmacodynamics of different doses of glucagon administered subcutaneously (s.c.) at different blood glucose levels. This study was an open-label, randomized, three-period, cross-over experiment in 6 patients with type 1 diabetes. During each of the three

  2. [SOMATOTYPE, NUTRITIONAL STATUS AND BLOOD GLUCOSE LEVEL OF PHYSICAL EDUCATION STUDENTS].

    Science.gov (United States)

    Valdés-Badilla, Pablo; Salvador Soler, Noemí; Godoy-Cumillaf, Andrés; Carmona-López, María Ines; Fernández, Juan José; Durán-Agüero, Samuel

    2015-09-01

    classical studies have compared the glycemia with the nutritional status in both children and adults; however studies that consider also somatotype are unknown. associating the somatotype and nutritional status with the glycemic level of students of Pedagogy in Physical Education (PPE). the sample included 40 subjects, divided between 13 women and 27 men. It was determined in each subject BMI, somatotype and also a fasting blood glucose sample was obtained. the somatotype in male PPE students was mesomorphic (3-2-2) with a nutritional status of overweight (25 kg/m2) and balanced mesomorphic (4-4-2) with normal weight (22 kg/m2) in women PPE students. While average fasting blood glucose was 69 mg / dl. No association between somatotype and BMI with blood sugar levels of students of PPE, however, women of PEF showed significant positive correlations between mesomorphy and the ICC (0.577) and between glycemia and height (0.650). somatotype and BMI of the students of PPE are consistent with their age and sex, but no association between somatotype and glucose was observed. Moreover, the average blood glucose levels were somewhat lower compared to normative tables, a situation that could be related to physical activity, however, requires further study to confirm it. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  3. Blood Glucose Monitoring as a Teaching Tool for Endocrinology: A New Perspective

    Science.gov (United States)

    Moats, Robert K., II

    2009-01-01

    The education of new allied health professionals and nurses in proper endocrine evaluation and care has become critical in recent years, especially considering the greatly increased prevalence of diabetes in adults and children. The evaluation of blood glucose levels in human volunteers over time is a powerful teaching tool for endocrinology that…

  4. Trend Estimation of Blood Glucose Level Fluctuations Based on Data Mining

    Directory of Open Access Journals (Sweden)

    Masaki Yamaguchi

    2003-06-01

    Full Text Available We have fabricated calorie-calculating software that calculates and records the total calorific food intake by choosing a meal menu selected using a computer mouse. The purpose of this software was to simplify data collection throughout a person's normal life, even if they were inexperienced computer operators. Three portable commercial devices have also been prepared a blood glucose monitor, a metabolic rate monitor and a mobile-computer, and linked into the calorie-calculating software. Time-course changes of the blood glucose level, metabolic rate and food intake were measured using these devices during a 3 month period. Based on the data collected in this study we could predict blood glucose levels of the next morning (FBG by modeling using data mining. Although a large error rate was found for predicting the absolute value, conditions could be found that improved the accuracy of the predicting trends in blood glucose level fluctuations by up to 90 %. However, in order to further improve the accuracy of estimation it was necessary to obtain further details about the patients' life style or to optimise the input variables that were dependent on each patient rather than collecting data over longer periods.

  5. Higher Blood Glucose within the Normal Range Is Associated with More Severe Strokes

    DEFF Research Database (Denmark)

    Martin, Rolf J; Ratan, Rajiv R; Reding, Michael J

    2012-01-01

    Background. Higher fasting blood glucose (FBG) concentrations in the hyperglycemic range are associated with more severe strokes. Whether this association also extends into patients with FBG in the normoglycemic range is unclear. We studied the association of stroke severity and FBG in normoglyce...

  6. Effect of glibenclamide on insulin release at moderate and high blood glucose levels in normal man

    NARCIS (Netherlands)

    Ligtenberg, JJM; Venker, CE; Sluiter, WJ; VanHaeften, TW

    Insulin release occurs in two phases; sulphonylurea derivatives may have different potencies in stimulating first-and second-phase insulin release. We studied the effect of glibenclamide on insulin secretion at submaximally and maximally stimulating blood glucose levels with a primed hyperglycaemic

  7. Blood flow and glucose metabolism in stage IV breast cancer: Heterogeneity of response during chemotherapy

    NARCIS (Netherlands)

    N.C. Krak (Nanda); J. van der Hoeven (John); O.S. Hoekstra (Otto); J.W.R. Twisk (Jos); E.E. van der Wall (Ernst); A.A. Lammertsma (Adriaan)

    2008-01-01

    textabstractObjective: The purpose of the study was to compare early changes in blood flow (BF) and glucose metabolism (MRglu) in metastatic breast cancer lesions of patients treated with chemotherapy. Methods: Eleven women with stage IV cancer and lesions in breast, lymph nodes, liver, and bone

  8. What do professionals recommend regarding the frequency of self-monitoring of blood glucose?

    NARCIS (Netherlands)

    Hortensius, J.; Kleefstra, N.; Houweling, S. T.; van der Bijl, J. J.; Gans, R. O. B.; Bilo, H. J. G.

    Background: Patients' adherence to guidelines regarding self-monitoring of blood glucose (SMBG) is limited. However, there are no previous reports about the recommendations that are given in clinical practice concerning SMBG. The aim of this study was to investigate what healthcare providers

  9. Adipose tissue insulin receptor and glucose transporter 4 expression, and blood glucose and insulin responses during glucose tolerance tests in transition Holstein cows with different body condition.

    Science.gov (United States)

    Jaakson, H; Karis, P; Ling, K; Ilves-Luht, A; Samarütel, J; Henno, M; Jõudu, I; Waldmann, A; Reimann, E; Pärn, P; Bruckmaier, R M; Gross, J J; Kaart, T; Kass, M; Ots, M

    2018-01-01

    Glucose uptake in tissues is mediated by insulin receptor (INSR) and glucose transporter 4 (GLUT4). The aim of this study was to examine the effect of body condition during the dry period on adipose tissue mRNA and protein expression of INSR and GLUT4, and on the dynamics of glucose and insulin following the i.v. glucose tolerance test in Holstein cows 21 d before (d -21) and after (d 21) calving. Cows were grouped as body condition score (BCS) ≤3.0 (thin, T; n = 14), BCS = 3.25 to 3.5 (optimal, O; n = 14), and BCS ≥3.75 (overconditioned, OC; n = 14). Blood was analyzed for glucose, insulin, fatty acids, and β-hydroxybutyrate concentrations. Adipose tissue was analyzed for INSR and GLUT4 mRNA and protein concentrations. During the glucose tolerance test 0.15 g/kg of body weight glucose was infused; blood was collected at -5, 5, 10, 20, 30, 40, 50, and 60 min, and analyzed for glucose and insulin. On d -21 the area under the curve (AUC) of glucose was smallest in group T (1,512 ± 33.9 mg/dL × min) and largest in group OC (1,783 ± 33.9 mg/dL × min), and different between all groups. Basal insulin on d -21 was lowest in group T (13.9 ± 2.32 µU/mL), which was different from group OC (24.9 ± 2.32 µU/mL. On d -21 the smallest AUC 5-60 of insulin in group T (5,308 ± 1,214 µU/mL × min) differed from the largest AUC in group OC (10,867 ± 1,215 µU/mL × min). Time to reach basal concentration of insulin in group OC (113 ± 14.1 min) was longer compared with group T (45 ± 14.1). The INSR mRNA abundance on d 21 was higher compared with d -21 in groups T (d -21: 3.3 ± 0.44; d 21: 5.9 ± 0.44) and O (d -21: 3.7 ± 0.45; d 21: 4.7 ± 0.45). The extent of INSR protein expression on d -21 was highest in group T (7.3 ± 0.74 ng/mL), differing from group O (4.6 ± 0.73 ng/mL), which had the lowest expression. The amount of GLUT4 protein on d -21 was lowest in group OC (1.2 ± 0.14 ng/mL), different from group O (1.8 ± 0.14 ng/mL), which had the highest amount

  10. Effect of Probiotics on Serum Biochemical and Blood Constituents in ...

    African Journals Online (AJOL)

    Purpose: To examine the effects of two commercial probiotics (Toyocerin and CloSTAT) on serum enzyme activities, and hematological and biochemical indices of broiler chickens challenged with Salmonella enterica serovars Typhimurium (ST). Methods: The chicks received one of the following treatments at 0 day of age: ...

  11. Relationship between maternal serum zinc, cord blood zinc and ...

    African Journals Online (AJOL)

    Background: Adequate in utero supply of zinc is essential for optimal fetal growth because of the role of zinc in cellular division, growth and differentiation. Low maternal serum zinc has been reported to be associated with low birth weight and the later is associated with increased morbidity and mortality in newborns.

  12. relationship between maternal serum zinc, cord blood zinc and birth

    African Journals Online (AJOL)

    FOBUR

    those obtained by Okonofua et al in Ile-Ife and. 17. Iqbal et al in Bangladesh but lower than the values. 18. 11 reported in studies in India and the United States. The similarity in the mean maternal serum zinc obtained in this study with the studies in Ife and. Bangladesh could be a reflection of the similarity among the study ...

  13. serum immunoglobulin levels in white, asiatic and bantu blood donors

    African Journals Online (AJOL)

    all assays were calculated as a percentage of the mean of. TABLE I. RESULTS OF IMMUNOGLOBULIN ASSAYS OF tOO WHITE, tOO ASIATIC AND 100 BANTU DONORS, EXPRESSED AS A. PERCENTAGE OF A CONTROL SERUM. Parameter. Range. Mean. Variance. Standard deviation. CoefI. of variation.

  14. Impairment of brain endothelial glucose transporter by methamphetamine causes blood-brain barrier dysfunction

    Directory of Open Access Journals (Sweden)

    Murrin L Charles

    2011-03-01

    Full Text Available Abstract Background Methamphetamine (METH, an addictive psycho-stimulant drug with euphoric effect is known to cause neurotoxicity due to oxidative stress, dopamine accumulation and glial cell activation. Here we hypothesized that METH-induced interference of glucose uptake and transport at the endothelium can disrupt the energy requirement of the blood-brain barrier (BBB function and integrity. We undertake this study because there is no report of METH effects on glucose uptake and transport across the blood-brain barrier (BBB to date. Results In this study, we demonstrate that METH-induced disruption of glucose uptake by endothelium lead to BBB dysfunction. Our data indicate that a low concentration of METH (20 μM increased the expression of glucose transporter protein-1 (GLUT1 in primary human brain endothelial cell (hBEC, main component of BBB without affecting the glucose uptake. A high concentration of 200 μM of METH decreased both the glucose uptake and GLUT1 protein levels in hBEC culture. Transcription process appeared to regulate the changes in METH-induced GLUT1 expression. METH-induced decrease in GLUT1 protein level was associated with reduction in BBB tight junction protein occludin and zonula occludens-1. Functional assessment of the trans-endothelial electrical resistance of the cell monolayers and permeability of dye tracers in animal model validated the pharmacokinetics and molecular findings that inhibition of glucose uptake by GLUT1 inhibitor cytochalasin B (CB aggravated the METH-induced disruption of the BBB integrity. Application of acetyl-L-carnitine suppressed the effects of METH on glucose uptake and BBB function. Conclusion Our findings suggest that impairment of GLUT1 at the brain endothelium by METH may contribute to energy-associated disruption of tight junction assembly and loss of BBB integrity.

  15. Cook and Chill: Effect of Temperature on the Performance of Nonequilibrated Blood Glucose Meters.

    Science.gov (United States)

    Deakin, Sherine; Steele, Dominic; Clarke, Sarah; Gribben, Cathryn; Bexley, Anne-Marie; Laan, Remmert; Kerr, David

    2015-08-20

    Exposure to extreme temperature can affect the performance of blood glucose monitoring systems. The aim was to determine the non-equilibrated performance of these systems at extreme high and low temperatures that can occur in daily life. The performances of 5 test systems, (1) Abbott FreeStyle Freedom Lite, (2) Roche AccuChek Aviva, (3) Bayer Contour, (4) LifeScan OneTouch Verio, and (5) Sanofi BG Star, were compared after "cooking" (50°C for 1 hour) or "chilling" (-5°C for 1 hour) with room temperature controls (23°C) using whole blood with glucose concentrations of 50, 100, and 200 mg/dl. The equilibration period (time from the end of incubation to when the test system is operational) was between 1 and 8 minutes, and each test system took between 15 and 30 minutes after incubation to obtain stable measurements at room temperature. Incubating the strips at -5°C or 50°C had little effect on the glucose measurement, whereas incubating the meters introduced bias in performance between 0 and 15 minutes but not subsequently, compared to room temperature controls and at all 3 glucose levels. Compensating technologies embedded within blood glucose monitoring systems studied here perform well at extreme temperatures. People with diabetes need to be alerted to this feature to avoid perceptions of malperformance of their devices and the possible inability to get blood glucose readings on short notice (eg, during time of suspected rapid change or before an unplanned meal). © 2015 Diabetes Technology Society.

  16. Serum selenium concentration in maternal and umbilical cord blood. Relation to course and outcome of pregnancy

    DEFF Research Database (Denmark)

    Bro, S; Berendtsen, H; Nørgaard, J

    1988-01-01

    The present knowledge of the role of selenium in human fetal and neonatal development is sparse. In this study we measured serum selenium concentrations in maternal and umbilical cord blood from 500 Danish mothers at delivery, looking for a relationship between various maternal and fetal complica......The present knowledge of the role of selenium in human fetal and neonatal development is sparse. In this study we measured