WorldWideScience

Sample records for serum electrolyte values

  1. Serum electrolytes changes in malnourished children with diarrhoea

    International Nuclear Information System (INIS)

    Memon, Y.; Majeed, R.; Shaikh, S.

    2007-01-01

    To determine the frequency of electrolyte disturbances in malnourished children with and without diarrhea and whether these findings have therapeutic value or not. It is a descriptive study conducted at pediatric Unit-II LUH Hyderabad, from 1st August to 31st September 2004. One hundred children of protein-calorie-malnutrition between 6 months to 5 year of age of either sex who were admitted due to diarrhoea, failure to thrive, acute respiratory infection, malaria, anemia, cardiac failure and feeding problems were included in the study. On the basis of history, physical examination and anthropometrics measurement they were divided into Group A patients (n=64) who were malnourished but had diarrhoea and Group B patients (n=36) who were also malnourished and had no diarrhoea. Serum electrolytes were done in patients of both groups and the results were analyzed statistically. Analysis of serum electrolyte in both groups revealed that hypokalemia, hyponatremia and low serum bicarbonate were seen more frequently in patients of group A as compared to group B. In group A hypokalemia was seen in 40 patients(62.5%) while it was observed in 8 patients (22.22%) in group B (p<0.001), hyponatremia was seen in 17 patients (26.56%) in group A and in 5 patients (13.88%) in group B (p<0.001). In group A 41 patients (64%) had low serum bicarbonate while in group B only 15 patients (41.66%) had low serum bicarbonate value (p<0.001) Electrolyte changes were commonly seen in grade II and III malnourished patients particularly who presented with diarrhoeal episode of variable duration. If these changes are diagnosed in time and treated appropriately the morbidity and mortality could be decreased. (author)

  2. SERUM ELECTROLYTES AND OUTCOME IN PATIENTS UNDERGOING ENDOSCOPIC GASTROSTOMY

    Directory of Open Access Journals (Sweden)

    Joana VIEIRA

    Full Text Available ABSTRACT BACKGROUND: Percutaneous endoscopic gastrostomy (PEG is a gold standard for long term enteral feeding. Neurologic dysphagia and head/neck cancer are the most common indications for PEG as they can lead to protein-energy malnutrition and serum electrolyte abnormalities, with potential negative impact on metabolic balance. Refeeding syndrome may also be related with severe electrolyte changes in PEG-fed patients and contribute to poor prognosis. OBJECTIVE: This study aims to evaluate the changes in serum concentrations of the main electrolytes and its possible association with the outcome. METHODS: Retrospective study of patients followed in our Artificial Nutrition Clinic, submitted to PEG from 2010 to 2016, having head/neck cancer or neurologic dysphagia, who died under PEG feeding. Serum electrolytes (sodium, potassium, chlorine, magnesium, calcium and phosphorus were evaluated immediately before the gastrostomy procedure. Survival after PEG until death was recorded in months. RESULTS: We evaluated 101 patients, 59 with electrolyte alterations at the moment of the gastrostomy. Sodium was altered in 32 (31.7%, magnesium in 21 (20.8%, chlorine in 21 (20.8%, potassium in 14 (13.8%, calcium in 11 (10.9 % and phosphorus in 11 (10.9%. The survival of patients with low sodium (<135 mmol/L was significantly lower when compared to patients with normal/high values, 2.76 months vs 7.80 months, respectively (P=0.007. CONCLUSION: Changes in serum electrolytes of patients undergoing PEG were very common. More than half showed at least one abnormality, at the time of the procedure. The most frequent was hyponatremia, which was associated with significantly shorter survival, probably reflecting severe systemic metabolic distress.

  3. Hematological, electrolyte and serum biochemical values of the Thai indigenous chickens (Gallus domesticus in northeastern, Thailand

    Directory of Open Access Journals (Sweden)

    Suchint Simaraks

    2005-05-01

    Full Text Available Thai indigenous chickens (Gallus domesticus have been domesticated in rural villages in Thailand for a long time. These birds are important to low-income people who live in the rural part of Thailand. However, health problems have been a major cause limiting their population. Hematological, electrolyte and serum biochemical values, which are important for diagnosis of clinical signs and symptoms when affected by diseases, are limited. Blood samples from 40 chickens (20 males and 20 females were used for hematological test while another 18 samples (from 10 males and 8 females were analysed for electrolyte and serum biochemical values. The samples were obtained from Khon Kaen, Kalasin, Roi - Et, Maha Sarakham and Nakhon Ratchasima provinces, northeastern region of Thailand. The results revealed the following information: total red blood cell count, hemoglobin concentration, packed cell volume, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, total white blood cell count, lymphocyte, heterophil, monocyte, eosinophil, basophil, H:L ratio values of Thai native chickens were 2.26 ± 0.29 × 106 cells/μl, 8.89 ± 1.20 g/dl, 32.18 ± 4.46%, 144.63 ± 18.61 fl, 39.69 ± 4.96 pg, 27.86 ± 3.37 g/dl, 2.04 ± 0.45 × 104 cells/μl, 63.68 ± 9.36%, 23.70 ± 7.21%, 4.20 ± 3.20%, 5.83 ± 3.53%, 2.65 ± 2.09% and 0.40 ± 0.17, respectively. Potassium, sodium and chloride values of Thai native chickens were 5.3 ± 0.8 mmol/l, 155.9 ± 3.1 mmol/l and 116.9 ± 2.7 mmol/l, respectively. Furthermore, serum biochemistry values of Thai native chickens such as total protein, glucose, alkaline phosphatase, uric acid, calcium and cholesterol were 4.6 ± 1.0 mg/dl, 190.2 ± 29.8 mg/dl, 235.9 ± 68.6 U/L, 5.0 ± 1.9 mg/dl, 10.4 ± 1.2 mg/dl and 102.4 ± 30.8 mg/dl, respectively. Besides, hemoglobin concentration, packed cell volume and eosinophil inthe males were significantly higher than in the females Thai indigenous

  4. Relationship between some serum electrolytes and ...

    African Journals Online (AJOL)

    ADEYEYE

    2014-02-03

    Feb 3, 2014 ... The effect of Trypanosoma brucei infection on changes in concentration of some serum electrolytes and the ... the modulatory responses of the autonomic nervous system ..... Concurrent hyponatremia and hypocalcemia have.

  5. STUDY OF SERUM ELECTROLYTES IN FEMALE THYROID PATIENTS : A CASE CONTROL STUDY

    Directory of Open Access Journals (Sweden)

    Neela Mannangi

    2015-02-01

    Full Text Available NTRODUCTION : Thyroid hormone is a central regulator of body haemodynamic, thermoregulation and metabolism. The effect of thyroid hormones on lipid metabolism is well known, whereas the effect on electrolytes and minerals has not been well established and also the underlying mechanisms not well understood. Thyroid hormones regulate the activity of sodium potassium pumps in mo st of the tissues. The higher prevalence of thyroid disease in women suggests that estrogen might be involved in the pathophysiology of thyroid dysfunction. With this background the present study was undertaken to assess the alterations in the levels of serum electrolytes in hyperthyroid, hypothyroid & euthyroid female patients. MATERIAL AND METHODS : The present study was conducted in female patients who atte nded medicine outpatient D epartment of S. N. Medical C ollege & HSK H ospital , Bagalkot . Thyroid hormones were estimated by chemiluminiscence method . Electrolyte levels (Na + , k + & Cl - were measured by ion selective electrode method. Serum levels of free T3 T4 and TSH were obtained. Patients with history of intake of thyroid drugs, hypertensive, diabetes mellitus, obesity and all other causes for electrolyte abnormalities were excluded from the study. STATISTICS : All the values are expressed in mean ± SD . Unp aired ‘t’ test was applied. Pearson’s correlation was done to see the correlation between serum electrolytes and thyroid hormones using SPSS (version 16.0. RESULTS : In the present study mean age group of patients were between 20 - 60yrs. There were 90 femal e patients total in number. Out of which 30 patients were with hypothyroidism, another 30 were with hyperthyroidism and remaining 30 were with euthyroidism. Mean serum levels for thyroid function parameters and electrolytes are given in below table no.2 an d 3. DISCUSSION : Hypothyroidism is a very common condition and seen more in women than in men. The higher prevalence of thyroid disease in

  6. Pattern of Serum Electrolytes Changes among Non Psychotic ...

    African Journals Online (AJOL)

    Method: Serum electrolytes, Na+, K+, Ca2+, Mg2+, were measured in 30 depressed patients at the Neuropsychiatric Hospital Rumuigbo, Port Harcourt before therapy commenced and after four (4) weeks of amitriptyline. Thirty (30) known non psychotic disordered subjects matched for age and sex were used as control.

  7. Effect of water electrolyte supplementation on performance, serum ...

    African Journals Online (AJOL)

    Under heat stress, 0.5% KCl and 0.5%NaCl supplementation in water reduced rectal temperature, increased body weight, improved FCR, and reduced blood pH. Electrolyte supplementation also influenced red blood cell count as well as serum levels of sodium, potassium and bicarbonate. Supplementing KCl and NaCl in ...

  8. Intraerythrocyte and serum electrolytes in diabetic patients hypertension

    International Nuclear Information System (INIS)

    Yasmin, F.; Haleem, D.J.; Haleem, M. A.

    2006-01-01

    To determine the serum and intraerythrocyte concentrations of vasoactive ions in patients of diabetes mellitus of either gender with hypertension. The study was conducted on 48 volunteers. Out of 48, 24(12 men and 12 women) were hypertensive patients with diabetes mellitus. Remaining (12 men and 12 women) were normal healthy subjects. Biochemical estimations were done by flame photometry and spectrophotometry. Data were analyzed by Two-way ANOVA followed by Newman-Keuls test. A decrease in serum concentrations of sodium, calcium, magnesium, phosphorus, chloride and intraerythrocyte potassium and an increase in the levels of glucose, haematocrit and intraerythrocyte sodium was observed in both male and female patients with diabetes mellitus and hypertension. No significant changes were observed in serum potassium levels. The results suggest that dysregulations of electrolyte balance caused by hyperinsulinemia or altered glucose metabolism may lead to hypertension. (author)

  9. Dose related anxiolytic effects of diazepam: relation with serum electrolytes, plasma osmolality and systolic blood pressure (sbp) in rats

    International Nuclear Information System (INIS)

    Farooq, R.; Haleem, D.J.; Haleem, M.A.

    2008-01-01

    Diazepam is an anxiolytic and anticonvulsant drug that also induces hypnosis. Changes in serum electrolyte balance, plasma osmolality and systolic blood pressure (SBP) are often associated with stress-induced anxiety. Administration of diazepam has been show to decrease stress-induced enhancement of hypothalamic pituitary adrenal cortical (HPA) axis. The present is designed to monitor the anxiolytic effects of different doses of diazepam (1 mg/kg, 2.5 mg/kg and 5 mg/kg) and its association with changes of serum electrolyte balance, plasma osmolality and SBP in rats. Administration of diazepam at doses of 1 mg/kg, 2.5 mg/kg and 5 mg/kg elicited anxiolytic effects monitored in light-dark transition test and increased serum concentration of electrolytes and plasma osmolality. Serum levels of magnesium as well as SBP decreased. The results are discussed in context of anxiolytic effects of diazepam to be mediated via a modulation of stress-induced increase in the activity of HPA-axis arid electrolytes balance. (author)

  10. Effect of different electrolyte balances in broiler diets

    Directory of Open Access Journals (Sweden)

    UM Arantes

    2013-09-01

    Full Text Available The aim of this study was to evaluate the performance, tibial density and mineral content, Na, K ,and Cl serum levels, and dry matter content of the litter of broilers fed diets with different levels of dietary electrolyte balances. Two experiments were carried out: during the starter phase (7 to 21 days of age, 960 broilers and during the growe phase (22 to 38 days of age, 816 broilers. In both experiments, a completely randomized design with four treatments based on dietary electrolyte balance values (200, 240, 280 and 320 mEq/kg of diet with four replicates was applied. Birds and diets were weighed when birds were seven, 14 and 21 days of age in the first experiment, and 22 and 38 days of age in the second experiment in order to determine weight gain, feed intake and feed conversion. Final body weight, weight gain, feed intake and feed conversion and mortality rate were evaluated. On days 21 and 38, the left tibia of two birds per replicate was collected to determine bone density and the serum was used for Na and K analysis. Litter dry matter content was also determined on days 21 and 38 . There was no effect of dietary electrolyte balance values on broilers performance between 7 and 14, 7 and 21, or 22 and 38 days of age, tibial bone density and mineral content, or on Na, K and Cl serum levels. Litter dry matter was linearly reduced as dietary electrolyte balance value increased. Diets with 200 mEq/kg may be recommended for broilers from 7 to 38 days of age with no negative influence on the evaluated parameters.

  11. A note on the electrolytic preparation of sup(99m)Tc human serum albumin

    International Nuclear Information System (INIS)

    Ligny, C.L. de; Dekker, B.G.

    1978-01-01

    A note to the simple electrolytic preparations of Tc-99m human serum albumin using tin electrodes, elaborated by Narasimhan and Mani, is described. Narasimhan and Mani's procedure yields mainly hydrolysed reduced Tc. Gil et al described a modification of Narasimhan and Mani's procedure wherein about 60% Tc-HSA chelate can be obtained. Purity analysis was performed by paper chromatography with 85% methanol as eluent. (T.I.)

  12. Reference Values for Plasma Electrolytes and Urea in Nigerian ...

    African Journals Online (AJOL)

    Reference values for plasma electrolytes and urea have been defined for Nigerian children and adolescents residing in Abeokuta and its environs, a location in southern Nigeria, by estimating plasma sodium, potassium bicarbonate and urea concentrations in a reference population. The study group comprised three ...

  13. Point-of-Admission Serum Electrolyte Profile of Children less than Five Years Old with Dehydration due to Acute Diarrhoea.

    Science.gov (United States)

    Okposio, Matthias Mariere; Onyiriuka, Alphonsus Ndidi; Abhulimhen-Iyoha, Blessing Imuetiyan

    2015-12-01

    Fluid, electrolytes and acid base disturbances are responsible for most deaths due to acute diarrhoea. The aim of this study is to describe the point-of-admission serum electrolyte profile of children with dehydration due to acute diarrhoea. In this cross-sectional study, the serum electrolyte levels of 185 children with dehydration due to acute diarrhoea were assessed at the point of admission at the Diarrhoea Treatment and Training Unit of the University of Benin Teaching Hospital. The age of the study population ranged from 29 days to 59 months. Out of a total of 185 subjects, 30 (16.2%), 114 (61.6%), and 41 (22.2%) had severe, moderate and mild dehydration, respectively. In addition, hyponatraemic dehydration was the most common type of dehydration, accounting for 60.5% of cases. Metabolic acidosis and hypokalaemia occurred in 59.5% and 44.3% of cases, respectively. Only the serum bicarbonate level was significantly affected by degree of dehydration (p = 0.001). Age of more than 12 months and presence of vomiting were significantly associated with hyponatraemia (p = 0.005 & p = 0.02), while age of less than or equal 12 months and absence of vomiting were associated with metabolic acidosis (p = 0.04 & p = 0.03). The degree of dehydration appears to be a good predictor of the occurrence of metabolic acidosis while age is a risk factor for hyponatraemia and metabolic acidosis.

  14. The effect of ramadan fasting and physical activity on body composition, serum osmolarity levels and some parameters of electrolytes in females.

    Science.gov (United States)

    Attarzadeh Hosseini, Seyyed Reza; Sardar, Mohammad Ali; Hejazi, Keyvan; Farahati, Samaneh

    2013-01-01

    So far, there have been a few and incoherent results about the effects of physical activities. Fasting in Ramadan has an effect on the level of osmolarity and the concentration of serum electrolytes both in active and inactive females. The aim of this study was to observe the changes of serum electrolytes and osmolarity levels according to regular exercise during fasting. TWENTY TWO HEALTHY FEMALES WHO WERE ELECTED BY CONVENIENCE SAMPLING METHOD WERE DIVIDED INTO TWO GROUPS: 1) fasting + exercise (FE; n = 11) and 2) fasting + non exercise (FNE; n = 15). The FE group participated in aerobic training for four sessions per week during the fasting. All measurements were done once before the first day, on the second week, on the fourth week and two weeks after fasting month and these measures were used to analyze test results. THE MEAN DIFFERENCES WERE AS FOLLOWS: significant weight loss, BMI, WHR, in two groups at the end of Ramadan (P 0.05). Potassium, creatinine, urea and uric acid had been decreased significantly in both groups (P Ramadan led to some changes in serum osmolarity index, electrolytes and water. Therefore, it is important for female athletes to consider applying a suitable nutritious diet and sufficient water consumption during Ramadan.

  15. Serum Trace Elements and Electrolytes Are Associated with Fasting Plasma Glucose and HbA1c in Postmenopausal Women with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Skalnaya, Margarita G; Skalny, Anatoly V; Yurasov, Vasily V; Demidov, Vasily A; Grabeklis, Andrei R; Radysh, Ivan V; Tinkov, Alexey A

    2017-05-01

    The primary aim of the research was to assess the level of trace elements and electrolytes in serum of postmenopausal diabetic women. Sixty-four postmenopausal women with type 2 diabetes mellitus (DM2) and 64 age- and body mass index-matched controls were examined. Serum trace elements were assessed using inductively coupled plasma dynamic reaction cell mass spectrometry (ICP-DRC-MS). Fasting plasma glucose (FPG) and glycated hemoglobin (HbA 1c ) levels were evaluated using Randox kits. The obtained data demonstrate that DM2 patients were characterized by 42 and 34 % higher FPG and HbA 1c levels, respectively (p women was increased by 10 and 15 % in comparison to the respective control values (p = 0.002 and DM2 pathogenesis. Further studies are required to assess the intimate mechanisms of the observed differences.

  16. Cutoff Values of Serum Carcinoembryonic Antigen (CEA) in Normal Korean Adults and Factors Influencing Serum CEA Level

    International Nuclear Information System (INIS)

    Kim, Jong Soon; Kim, Sun Wook; Chung, June Key; Lee, Dong Soo

    1994-01-01

    Carcinoembryonic Antigen is one of most frequently checked tumor markers in cancer management. We performed statistical analysis with serum CEA data of 2626 persons who received regular health examination and were thought to be free of active disease to determine the cutoff values of serum CEA level in normal Korean adults and to study the factors influencing serum CEA levels in normal subjects. 1) The cutoff values of serum CEA in normal Korean adults in general were 9.28 ng/ml for men, 5.90 ng/ml for women. 2) Serum CEA level was influenced by age, present smoking history, sex, and abnormal findings in chest X ray. 3) Serum CEA level had no correlation with the history of amount of alcohol consumption or obesity. 4) Cutoff values of serum CEA in normal Korean adults were tabulated according to age, sex, and smoking history. Serum CEA level was influenced by age, sex, present smoking history and abnormal findings in chest X ray and cutoff values of serum CEA were tabulated according to age, sex, and smoking history.

  17. Assessment of cabozantinib treatment on QT interval in a phase 3 study in medullary thyroid cancer: evaluation of indirect QT effects mediated through treatment-induced changes in serum electrolytes.

    Science.gov (United States)

    Miles, Dale R; Lacy, Steven A; Wada, David R; Milwee, Steve; Yaron, Yifah; Nguyen, Linh T

    2017-08-01

    This study evaluated factors impacting QTc interval in a phase 3 trial of cabozantinib in progressive, metastatic, medullary thyroid cancer (MTC). Electrocardiogram (12-lead ECG) measurements were obtained at screening, and at pre-dose, and 2, 4, and 6 h post-dose on Days 1 and 29 in a phase 3 study in patients with MTC treated with cabozantinib (140 mg/day). Central tendency analyses were conducted on baseline-corrected QTc values. Linear and nonlinear mixed-effects models were used to evaluate potential factors affecting the QTc interval, including serum electrolytes, patient demographics, and cabozantinib concentration. Central tendency analysis showed that oral cabozantinib (140 mg/day) produced a 10-15 ms increase in delta-delta Fridericia corrected QT (∆∆QTcF) and delta-delta study-specific corrected QT (∆∆QTcS) on Day 29, but not on Day 1. Further analysis showed that QTcS provided a slightly more accurate QT correction than QTcF. Mixed-effects models evaluating serum electrolytes, age, sex, and cabozantinib concentration showed that decreased serum calcium and potassium could explain the majority of cabozantinib treatment-associated QTcS prolongation observed in this study. Cabozantinib treatment prolongs the ∆∆QTcF interval by 10-15 ms. There was the absence of a strong relationship between cabozantinib concentration and QTcS prolongation. Cabozantinib treatment effects on serum calcium and potassium best explain the QTcS prolongation observed in this study.

  18. Preoperative fluid and electrolyte management with oral rehydration therapy.

    Science.gov (United States)

    Taniguchi, Hideki; Sasaki, Toshio; Fujita, Hisae; Takamori, Mina; Kawasaki, Rieko; Momiyama, Yukinori; Takano, Osami; Shibata, Toshinari; Goto, Takahisa

    2009-01-01

    We hypothesized that oral rehydration therapy using an oral rehydration solution may be effective for preoperative fluid and electrolyte management in surgical patients before the induction of general anesthesia, and we investigated the safety and effectiveness of oral rehydration therapy as compared with intravenous therapy. Fifty female patients who underwent breast surgery were randomly allocated to two groups. Before entry to the operation room and the induction of general anesthesia, 25 patients drank 1000 ml of an oral rehydration solution ("oral group") and 25 patients were infused with 1000 ml of an intravenous electrolyte solution ("intravenous group"). Parameters such as electrolyte concentrations in serum and urine, urine volume, vital signs, vomiting and aspiration, volumes of esophageal-pharyngeal fluid and gastric fluid (EPGF), and patient satisfaction with the therapy (as surveyed by a questionnaire) were assessed. After treatment, the serum sodium concentration and the hematocrit value, which both declined within the normal limits, were significantly higher in the oral group than in the intravenous group (sodium, 140.8 +/- 2.9 mEq x l(-1) in the oral group and 138.7 +/- 1.9 mEq x l(-1) in the intravenous group; P = 0.005; hematocrit, 39.03 +/- 4.16% in the oral group and 36.15 +/- 3.41% in the intravenous group; P = 0.01). No significant difference was observed in serum glucose values. Urine volume was significantly larger in the oral group (864.9 +/- 211.5 ml) than in the intravenous group (561.5 +/- 216.0 ml; P rehydration therapy, as judged by factors such as "feeling of hunger", "occurrence of dry mouth", and "less restriction in physical activity". The volume of EPGF collected following the induction of anesthesia was significantly smaller in the oral group than in the intravenous group (6.03 +/- 9.14 ml in the oral group and 21.76 +/- 30.56 ml in the intravenous group; P rehydration therapy with an oral rehydration solution before surgery is

  19. Polymer Electrolytes

    Science.gov (United States)

    Hallinan, Daniel T.; Balsara, Nitash P.

    2013-07-01

    This review article covers applications in which polymer electrolytes are used: lithium batteries, fuel cells, and water desalination. The ideas of electrochemical potential, salt activity, and ion transport are presented in the context of these applications. Potential is defined, and we show how a cell potential measurement can be used to ascertain salt activity. The transport parameters needed to fully specify a binary electrolyte (salt + solvent) are presented. We define five fundamentally different types of homogeneous electrolytes: type I (classical liquid electrolytes), type II (gel electrolytes), type III (dry polymer electrolytes), type IV (dry single-ion-conducting polymer electrolytes), and type V (solvated single-ion-conducting polymer electrolytes). Typical values of transport parameters are provided for all types of electrolytes. Comparison among the values provides insight into the transport mechanisms occurring in polymer electrolytes. It is desirable to decouple the mechanical properties of polymer electrolyte membranes from the ionic conductivity. One way to accomplish this is through the development of microphase-separated polymers, wherein one of the microphases conducts ions while the other enhances the mechanical rigidity of the heterogeneous polymer electrolyte. We cover all three types of conducting polymer electrolyte phases (types III, IV, and V). We present a simple framework that relates the transport parameters of heterogeneous electrolytes to homogeneous analogs. We conclude by discussing electrochemical stability of electrolytes and the effects of water contamination because of their relevance to applications such as lithium ion batteries.

  20. Influence of mixed electrolytes and pH on adsorption of bovine serum albumin in hydrophobic interaction chromatography.

    Science.gov (United States)

    Hackemann, Eva; Hasse, Hans

    2017-10-27

    Using salt mixtures instead of single salts can be beneficial for hydrophobic interaction chromatography (HIC). The effect of electrolytes on the adsorption of proteins, however, depends on the pH. Little is known on that dependence for mixed electrolytes. Therefore, the effect of the pH on protein adsorption from aqueous solutions containing mixed salts is systematically studied in the present work for a model system: the adsorption of bovine serum albumin (BSA) on the mildly hydrophobic resin Toyopearl PPG-600M. The pH is adjusted to 4.0, 4.7 or 7.0 using 25mM sodium phosphate or sodium citrate buffer. Binary and ternary salt mixtures of sodium chloride, ammonium chloride, sodium sulfate and ammonium sulfate as well as the pure salts are used at overall ionic strengths between 1500 and 4200mM. The temperature is always 25°C. The influence of the mixed electrolytes on the adsorption behavior of BSA changes completely with varying pH. Positive as well as negative cooperative effects of the mixed electrolytes are observed. The results are analyzed using a mathematical model which was recently introduced by our group. In that model the influence of the electrolytes is described by a Taylor series expansion in the individual ion molarities. After suitable parametrization using a subset of the data determined in the present work, the model successfully predicts the influence of mixed electrolytes on the protein adsorption. Furthermore, results for BSA from the present study are compared to literature data for lysozyme, which are available for the same adsorbent, temperature and salts. By calculating the ratio of the loading of the adsorbent for both proteins particularly favorable separation conditions can be selected. Hence, a model-based optimization of solvents for protein separation is possible. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Comparing the Effect of Fasting and Physical Activity on Active and Non-active Males’ Body Composition, Serum Osmolarity Levels and Some Parameters of Electrolytes

    Directory of Open Access Journals (Sweden)

    M Nematy

    2012-08-01

    Full Text Available Introduction: Ever since there is insufficient and incoherent information about the effect of the Ramadan Fasting together with regular exercise on levels of serum osmolarity, and electrolytes concentration. The aim of this study was to compare the effect of fasting and physical activity on active and non-active males’ body composition, serum osmolarity levels and some parameters of electrolytes. Methods: Twenty six healthy males, who were selected by convenience sampling method, were divided into two (active and non-active groups. The Active group participated in football training for three sessions per week during the fasting month. All measurements were repeated on the first and last day of fasting month and were used to analyze the test results. Results: The average differences were significantly decreased in weight, BMI, WHR, mineral, total water in two groups (P≤0.05. There was a significant difference in average of BMI, WHR, body fat, mineral and total water between two groups (P≤0.05. Within-group mean differences in glucose, potassium, urine and albumin in both groups were significant (P≤0.05. Differences of serum osmolarity in between- and within-groups were not significant in both groups. While, glucose decreased significantly, the levels of the protein decreased, and urea increased significantly only in non active fasting group. Conclusion: According to these results, regular exercise together with the Ramadan fasting result in change in some serum osmolarity index, electrolytes and water. Therefore, it is necessary to protect the athletics against the malnutrition in Ramadan fasting by using the diet schedule and enough water.

  2. Citrate metabolism and its complications in non-massive blood transfusions: association with decompensated metabolic alkalosis+respiratory acidosis and serum electrolyte levels.

    Science.gov (United States)

    Bıçakçı, Zafer; Olcay, Lale

    2014-06-01

    Metabolic alkalosis, which is a non-massive blood transfusion complication, is not reported in the literature although metabolic alkalosis dependent on citrate metabolism is reported to be a massive blood transfusion complication. The aim of this study was to investigate the effect of elevated carbon dioxide production due to citrate metabolism and serum electrolyte imbalance in patients who received frequent non-massive blood transfusions. Fifteen inpatients who were diagnosed with different conditions and who received frequent blood transfusions (10-30 ml/kg/day) were prospectively evaluated. Patients who had initial metabolic alkalosis (bicarbonate>26 mmol/l), who needed at least one intensive blood transfusion in one-to-three days for a period of at least 15 days, and whose total transfusion amount did not fit the massive blood transfusion definition (alkalosis+respiratory acidosis developed as a result of citrate metabolism. There was a positive correlation between cumulative amount of citrate and the use of fresh frozen plasma, venous blood pH, ionized calcium, serum-blood gas sodium and mortality, whereas there was a negative correlation between cumulative amount of citrate and serum calcium levels, serum phosphorus levels and amount of urine chloride. In non-massive, but frequent blood transfusions, elevated carbon dioxide production due to citrate metabolism causes intracellular acidosis. As a result of intracellular acidosis compensation, decompensated metabolic alkalosis+respiratory acidosis and electrolyte imbalance may develop. This situation may contribute to the increase in mortality. In conclusion, it should be noted that non-massive, but frequent blood transfusions may result in certain complications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Critical serum creatinine values in very preterm newborns.

    Directory of Open Access Journals (Sweden)

    Alexandra Bruel

    Full Text Available BACKGROUND: Renal failure in neonates is associated with an increased risk of mortality and morbidity. But critical values are not known. OBJECTIVE: To define critical values for serum creatinine levels by gestational age in preterm infants, as a predictive factor for mortality and morbidity. STUDY DESIGN: This was a retrospective study of all preterm infants born before 33 weeks of gestational age, hospitalized in Nantes University Hospital NICU between 2003 and 2009, with serum creatinine levels measured between postnatal days 3 to 30. Children were retrospectively randomized into either training or validation set. Critical creatinine values were defined within the training set as the 90(th percentile values of highest serum creatinine (HSCr in infants with optimal neurodevelopmental at two years of age. The relationship between these critical creatinine values and neonatal mortality, and non-optimal neural development at two years, was then assessed in the validation set. RESULTS AND CONCLUSION: The analysis involved a total of 1,461 infants (gestational ages of 24-27 weeks (n=322, 28-29 weeks (n=336, and 30-32 weeks (803, and 14,721 creatinine assessments. The critical values determined in the training set (n=485 were 1.6, 1.1 and 1.0 mg/dL for each gestational age group, respectively. In the validation set (n=976, a serum creatinine level above the critical value was significantly associated with neonatal mortality (Odds ratio: 8.55 (95% confidence interval: 4.23-17.28; p<0.01 after adjusting for known renal failure risk factors, and with non-optimal neurodevelopmental outcome at two years (odds ratio: 2.06 (95% confidence interval: 1.26-3.36; p=0.004 before adjustment. Creatinine values greater than 1.6, 1.1 and 1.0 mg/dL respectively at 24-27, 28-29, 30-32 weeks of gestation were associated with mortality before and after adjustment for risk factors, and with non-optimal neurodevelopmental outcome, before adjustment.

  4. Oral rehydration therapy for preoperative fluid and electrolyte management.

    Science.gov (United States)

    Taniguchi, Hideki; Sasaki, Toshio; Fujita, Hisae

    2011-01-01

    Preoperative fluid and electrolyte management is usually performed by intravenous therapy. We investigated the safety and effectiveness of oral rehydration therapy (ORT) for preoperative fluid and electrolyte management of surgical patients. The study consisted of two studies, designed as a prospective observational study. In a pilot study, 20 surgical patients consumed 1000 mL of an oral rehydration solution (ORS) until 2 h before induction of general anesthesia. Parameters such as serum electrolyte concentrations, fractional excretion of sodium (FENa) as an index of renal blood flow, volume of esophageal-pharyngeal fluid and gastric fluid (EPGF), and patient satisfaction with ORT were assessed. In a follow-up study to assess the safety of ORT, 1078 surgical patients, who consumed ORS until 2 h before induction of general anesthesia, were assessed. In the pilot study, water, electrolytes, and carbohydrate were effectively and safely supplied by ORT. The FENa value was increased at 2 h following ORT. The volume of EPGF collected following the induction of anesthesia was 5.3±5.6 mL. In the follow-up study, a small amount of vomiting occurred in one patient, and no aspiration occurred in the patients. These results suggest that ORT is a safe and effective therapy for the preoperative fluid and electrolyte management of selected surgical patients.

  5. Relationship of Renal Function Tests and Electrolyte Levels with Severity of Dehydration in Acute Diarrhea.

    Science.gov (United States)

    Gauchan, E; Malla, K K

    2015-01-01

    Acute diarrheal illness constitutes a major cause of morbidity and mortality in children in developing countries. Most of the complications of diarrhea occur due to excessive fluid and electrolyte loss; adverse complications are seen more with increasing severity of dehydration. This study was conducted to identify the relation of renal function and electrolyte abnormalities in children with varying severity of dehydration. This study was carried out in Manipal Teaching Hospital, Pokhara, Nepal over duration of one year. The aims were to find out the association of renal function and electrolyte disturbances with type of diarrhea, severity of dehydration and their relation to outcome. All children more than one month and less than 15 years with acute diarrhea were included in the study. Data were entered and analyzed by SPSS version 19. Statistical analysis applied was Chi-square test. A p-value of Dehydration was associated more with Acute Watery Diarrhea than with Invasive Diarrhea. Renal function and electrolyte abnormalities were seen more in Acute Watery Diarrhea with increasing levels of blood urea, serum creatinine and abnormal levels of serum sodium seen with increased severity of dehydration. Abnormalities in renal function and electrolytes correlated significantly with severity of dehydration. The outcome of patients correlated with severity of dehydration with mortality occurring in 18.1% of patients with Severe dehydration, 0.8% of Some dehydration with no mortality in the No dehydration group.

  6. Respiratory alkalosis and associated electrolytes in long-term ventilator dependent persons with tetraplegia.

    Science.gov (United States)

    Watt, J W; Silva, P

    2001-11-01

    A pilot case control study of the acid-base and electrolyte status in 30 long-term ventilator-dependent (LTVD) and 30 self ventilating persons with tetraplegia. To assess the extent of respiratory alkalosis and screen for associated hypokalaemia, hypomagnesaemia and/or hypophosphataemia. Medically stable persons with tetraplegia under the long-term care of the Southport Spinal Injuries Centre, England. Blood gases and electrolytes were sampled from 30 control patients with tetraplegia and from 30 patients having been LTVD for more than 12 months. All the blood gas measurements in the LTVD group lay outside both the reference range and the 95% confidence intervals (CI) of the control group: pH 7.46 (0.06); PCO(2) 3.46 (1.1) kPa; bicarbonate 18.3 (3.8) and base excess -3.2 (2.8) mmol/l; PO(2) 13.8 (2.8) kPa (means and standard deviations). The serum potassium, magnesium, phosphate, and sodium means lay within the reference ranges but the potassium, phosphate and calcium were at or below the 95% CI of the control values. One patient on part-time ventilatory support having less bicarbonate compensation had low serum electrolytes during ventilation. There was no evidence of biochemical jeopardy from long-term mechanical hyperventilation although acutely administered hyperventilation has the potential to cause falls in serum potassium, magnesium and phosphate and so caution should be exercised in part-time ventilated persons. The full range of electrolytes should be assayed during stabilisation in LTVD and periodically thereafter. Hyperventilation helps to maintain good oxygenation in LTVD persons with paralysis and normal lungs. None.

  7. Responses of serum electrolytes of goats to twelve hours of road transportation during the hot-dry season in Nigeria, and the effect of pretreatment with ascorbic acid

    Directory of Open Access Journals (Sweden)

    J.O. Ayo

    2009-09-01

    Full Text Available Twenty goats which served as the experimental group were administered ascorbic acid (AA per os at a dosage rate of 100 mg/kg body mass, while 20 others served as controls and were given 10 mt each of sterile water. Forty minutes after the administration and loading, the goats were transported for 12 h. Handling and loading of the experimental and control groups of goats decreased (P < 0.05 the potassium and sodium serum concentrations. The concentration of serum chloride, sodium and calcium increased significantly (P< 0.05 immediately post-transportation, while potassium and magnesium decreased (P < 0.05 in the control goats. In AA-treated goats sodium and magnesium concentrations decreased abruptly (P< 0.05, while calcium increased significantly (P< 0.05 after transportation. Handling, loading and transportation adversely affected the electrolyte balance of the goats which suggested respiratory alkalosis, dehydration and muscular damage in the transported goats, and the administration of AA alleviated the adverse effects of road transportation stress on serum electrolytes.

  8. Multiple Electrolyte and Metabolic Emergencies in a Single Patient

    Directory of Open Access Journals (Sweden)

    Caprice Cadacio

    2017-01-01

    Full Text Available While some electrolyte disturbances are immediately life-threatening and must be emergently treated, others may be delayed without immediate adverse consequences. We discuss a patient with alcoholism and diabetes mellitus type 2 who presented with volume depletion and multiple life-threatening electrolyte and metabolic derangements including severe hyponatremia (serum sodium concentration [SNa] 107 mEq/L, hypophosphatemia (“undetectable,” <1.0 mg/dL, and hypokalemia (2.2 mEq/L, moderate diabetic ketoacidosis ([DKA], pH 7.21, serum anion gap [SAG] 37 and hypocalcemia (ionized calcium 4.0 mg/dL, mild hypomagnesemia (1.6 mg/dL, and electrocardiogram with prolonged QTc. Following two liters of normal saline and associated increase in SNa by 4 mEq/L and serum osmolality by 2.4 mosm/Kg, renal service was consulted. We were challenged with minimizing the correction of SNa (or effective serum osmolality to avoid the osmotic demyelinating syndrome while replacing volume, potassium, phosphorus, calcium, and magnesium and concurrently treating DKA. Our management plan was further complicated by an episode of significant aquaresis. A stepwise approach was strategized to prioritize and correct all disturbances with considerations that the treatment of one condition could affect or directly worsen another. The current case demonstrates that a thorough understanding of electrolyte physiology is required in managing complex electrolyte disturbances to avoid disastrous outcomes.

  9. The differential diagnostic value of serum homocysteine for white coat hypertension

    OpenAIRE

    Guo, Shitian; Lin, Hui; Pan, Sunlei; Zhai, Xiaoya; Meng, Liping

    2017-01-01

    Objective To assess the value of serum homocysteine (Hcy) in differential diagnosis of white coat hypertension (WCH). Results In this retrospective study, serum Hcy levels were elevated in hypertensive patients (P < 0.001) compared to WCH patients. Serum Hcy levels were positively correlated with 24-h mean systolic blood pressure, r = 0.1378, P < 0.001. The results of the receiving operating characteristic (ROC) curve showed that the AUC value of Hcy was 0.80 (95% CI, 0.77–0.83), the cut-off ...

  10. EFFECT OF MULTIPARITY ON ELECTROLYTE COMPOSITION ...

    African Journals Online (AJOL)

    Daniel Owu

    Serum electrolytes (Na+, K+ and Cl-) were measured using standard ... There was also no significant difference in blood pressure among the groups and between ... substances as well as exaggerated response to posture. (Korda, 1987).

  11. Evaluation of clinical value of serum CA19-9

    International Nuclear Information System (INIS)

    Lv Haifeng; Lin Zhiyu; Lu Xiaozhuo; Chen Yini

    2003-01-01

    The article is to study the clinical significance of serum CA19-9 in diagnosing malignant tumor occurred in digestive system and to select cut off values for differentiating diagnosis of a pancreatic neoplasms and pancreatitis. Using chemiluminescence immunoassay, serum CA19-9 level of below subjects were analyzed: control group (n=21); digestive system neoplasm group (n=125, with 7 cases conformed as pancreatic cancer); non-neoplastic disease group (n=387, with 15 cases conformed as pancreatitis secondary to destructive cholangitis). Receiver operating characteristic (ROC) curve was used for analyzing results and selecting cut off values. When cut off value was 18.4 kU/L, sensibility for conforming a digestive system neoplasm was 60.8%, while its related specificity against control group and non-neoplastic disease group was 95. 2% and 68.2%, respectively. Sensibility for diagnosing pancreatic neoplasm was 85.7%, while its related specificity against control group and non-pancreatic origin tumor group was 95.0% and 63.1%, respectively. When 37 kU/L was chosen as cut off value, specificity for differentiating diagnosis of pancreatic neoplasm and pancreatitis secondary to destructive cholangitis rose from 13.3% to 46.7%. Serum CA19-9 could be used as an aid in detecting digestive system neoplastic disease; it is a reliable marker for pancreatic neoplasm. Raising cut off value may help to differentiate pancreatic neoplasm and pancreatitis secondary to destructive cholangitis

  12. Effect of organic contrast Media on the haematology and Serum ...

    African Journals Online (AJOL)

    Key Words: Contrast media, haematology, serum electrolytes, dogs, xylazine. The effect of contrast media on the hematology and serum electrolyte was determined in five dogs sedated with 2mg/kg of xylazine intramuscular (i.m). A total of 800mg/kg bolus of 76% urograffin was then administered by intravenous injection ...

  13. Mother and Infant Body Mass Index, Breast Milk Leptin and Their Serum Leptin Values.

    Science.gov (United States)

    Savino, Francesco; Sardo, Allegra; Rossi, Lorenza; Benetti, Stefania; Savino, Andrea; Silvestro, Leandra

    2016-06-21

    This study investigates correlations between mother and infant Body Mass Index (BMI), their serum leptin values and breast milk leptin concentration in early infancy. We determined serum leptin values in 58 healthy infants and leptin values in their mothers' breast milk, using radioimmunoassay (RIA). Infant and maternal anthropometrics were measured. Median leptin concentration was 3.9 ng/mL (interquartile range (IQR): 2.75) in infant serum, 4.27 ng/mL (IQR: 5.62) in maternal serum and 0.89 ng/mL (IQR: 1.32) in breast milk. Median maternal BMI and weight were 24 kg/m² (IQR: 4.41) and 64 kg (IQR: 15). Median infant BMI was 15.80 kg/cm² (IQR: 4.02), while average weight was 5.130 kg (IQR: 1.627). Infants serum leptin values positively correlated with infants' BMI (p = 0.001; r = 0.213) and breast milk leptin (p = 0.03; r = 0.285). Maternal serum leptin values positively correlated with maternal BMI (p = 0.000, r = 0.449) and breast milk leptin ones (p = 0.026; r = 0.322). Breast milk leptin and maternal BMI could influence infant serum leptin values. Further studies are needed to better elucidate the role of genetics and environment on infant leptin production and risk of obesity later in life.

  14. Radioimmunoassay of serum digoxin levels in digitalis intoxication

    International Nuclear Information System (INIS)

    Arendt, G.

    1981-01-01

    For 101 hospitalized patients where clinical symptoms of a glucosidine intoxication as a consequence of oral digoxin treatment were noted, serum digoxin levels were determined using a RIA kit of the Boehringer company (I-125 tracer, solid phase tube separation technique) on a fasted stomach prior to oral drug administration. An ECG was performed simultaneously and in addition kidney function parameters and electrolyte levels were determined. An anamnesis and clinical examination of the patients were also conducted. Interferences in the RIA method and gastro-intestinal illness resulting in changes in resorption behaviour were excluded. The group of patients showed collectively an average serum digoxin level of 2.9 +- 0.9 ng/ml with a range from 1.8 to 6.8 ng/ml, which was statistically significantly higher than the average value for 101 patients receiving long-term oral medication but without symptoms of glycosidine intoxication. According to the manufacture's specifications for the RIA kit, values > 2.0 ng/ml are considered as toxic, with values between 1.6 and 2.0 ng/mg falling into a ''grey zone''. A correlation was found between toxic serum values with changes in ECG pattern and subjective clinical symptoms of intoxication. A limitation of kidney function was responsible for the high serum glycoside levels in 62% of the patients. It was shown that the differing response of patients towards digitalis medication, above all in the case of long-term therapy, warrants an RIA determination of serum glycoside values in order to adjust the digoxin dose to individual requirements. (orig./MG) [de

  15. A CORRELATIONAL STUDY BETWEEN CHANGES IN SERUM ELECTROLYTES (NA, K, CL, MG AND ACUTE MYOCARDIAL INFARCTION COMPLICATION

    Directory of Open Access Journals (Sweden)

    Ketan Bharatbhai Parmar

    2017-08-01

    Full Text Available BACKGROUND The term "arrhythmia" refers to any change from the normal sequence of electrical impulses. The electrical impulses may happen too fast, too slowly or erratically causing the heart to beat too fast, too slowly or erratically. When the heart doesn't beat properly, it can't pump blood effectively. When the heart doesn't pump blood effectively, the lungs, brain and all other organs can't work properly and may shutdown or be damaged. Normally, the heart's most rapidly firing cells are in the sinus (or sino-atrial or SA node making that area a natural pacemaker. Under some conditions, almost all heart tissue can start an impulse of the type that can generate a heartbeat. Cells in the heart's conduction system can fire automatically and start electrical activity. This activity can interrupt the normal order of the heart's pumping activity. Secondary pacemakers elsewhere in the heart provide a "backup" rhythm when the sinus node doesn't work properly or when impulses are blocked somewhere in the conduction system. An arrhythmia occurs when the heart's natural pacemaker develops an abnormal rate or rhythm. The normal conduction pathway is interrupted. Another part of the heart takes over as pacemaker. The aim of the study is to observe the prevalence of various electrolyte (Na, K, Cl and Mg imbalances in complications of arrhythmias. MATERIALS AND METHODS This is a prospective study in which the patient admitted with signs and symptoms of cardiac arrhythmias diagnosed clinically, 100 cases were selected over 1 year. RESULTS The serum magnesium, sodium and potassium levels were significantly lower in the AMI patients at baseline and gradually becomes near normal on 4th day. K and Mg are showing significant difference between pre and post values in males and Mg show significant difference between pre and post values day 1 and day 5 in females with arrhythmia. CONCLUSION Persistent hyponatraemia is indication of worsening cardiac failure and

  16. EXPERIMENTALLY-DERIVED FORMULA FOR COMPUTING SERUM OSMOLARITY IN CHICKENS

    Directory of Open Access Journals (Sweden)

    RODICA CĂPRIŢĂ

    2007-10-01

    Full Text Available Osmolarity is a colligative property of solutions that depends on the number ofdissolved particles. The three types of solutes most encountered in biological fluidsare electrolytes, organic non-electrolyte molecules and colloids. The osmolarity ofthe extracellular fluid is about equal to that of the intracellular fluid, although thereare significant differences in the ionic composition of the two compartments. Plasmaosmolarity is a convenient and accurate guide to intracellular osmolarity. There areseveral different formulas for the calculation of human serum osmolarity. The goalof this study is to estimate the plasma osmolarity in chickens from theconcentrations of the main electrolytes and the glucose and urea content, and toestablish the contribution of each osmotic component. Linear regression analysiswas carried out to determine the best predictors of serum osmolarity in chickens.Two equations were also deduced for calculating serum osmolarity using manualregression analysis.

  17. Evaluating the effect of administrating hypertonic and isotonic saline solutions on clinical improvement, serum electrolyte concentrations and renal function of calves affected by diarrhea

    Directory of Open Access Journals (Sweden)

    A Hasanpour

    2009-11-01

    This study was conducted on 40 calves under the age of one mouth with 30 calves affected by diarrhea allocated to 3 treatment groups of 10 calves each and the control group consisting of 10 calves. The control group received neither treatment nor any injections. In the first treatment group, only antibiotics were administered without any fluid therapy. In the second treatment group, apart from antibiotic therapy of diarrhea, hypertonic saline solution (7.5% was administered at a dose of 5 ml/kg as slow intravenous infusion alongside oral ORS solution whereas in the third treatment group isotonic saline solution (0.9% was given intravenously according to the formula (Body weight × %Dehydration alongside oral ORS solution. In all groups, clinical examination and blood sampling was undertaken at times 0, 1, 2, 8 and 24 hours following treatment. At time 0, the diarrhea had resulted in clinical and laboratory signs such as a fever, the dehydration, tachycardia, oligopnea, increased packed sell volume, hypernatremia, hyperchloremia, hyperkalemia, hyperphosphatemia, hypercalcemia, increased serum creatinine and BUN values. Following treatment, fever subsided and the dehydration was corrected and this correction occurred faster in calves which had received hypertonic saline solution. Correction of sodium, potassium, chloride, phosphorus and calsium imbalance occurred faster in patients which were treated by hypertonic solution. Fluid therapy with saline solutions prevented the increase in serum creatinine and BUN values. In conclusion, the administration of hypertonic saline solutions leads to much faster and more reliable clinical improvement and electrolyte imbalance correction in calves affected by diarrhea.

  18. The clinical value of serum PSA and PAP determinations in prostate cancer patients

    International Nuclear Information System (INIS)

    Zeng Lei; Yu Renbo; Du Guowei; Pang Baozhong

    2001-01-01

    Objective: To investigate the clinical value of serum PSA and PAP determinations in diagnosis of prostate cancer patients. Methods: The serum PSA and PAP levels of 98 prostate cancer patients, 45 prostate benign disease patients and 40 normal subjects were tested by IRMA. Results: The serum PSA and PAP levels of prostate cancer patients were significantly higher than those in prostate benign disease patients and normal controls (P < 0.01). The diagnostic sensitivity and specificity of serum PSA for prostate cancer were 93.9% and 93.3% respectively. The diagnostic sensitivity and specificity of serum PAP for prostate cancer were 71.4% and 91.1% respectively. Conclusion: The determination of serum PSA and PAP was of high clinical value for diagnosis of early prostate cancer. It could be used as an important reference parameter for the clinical staging, follow-up of treatment result and prediction of prognosis

  19. In-vivo study for anti-hyperglycemic potential of aqueous extract of Basil seeds (Ocimum basilicum Linn) and its influence on biochemical parameters, serum electrolytes and haematological indices.

    Science.gov (United States)

    Chaudhary, Sachin; Semwal, Amit; Kumar, Hitesh; Verma, Harish Chandra; Kumar, Amit

    2016-12-01

    The study introduced anti-hyperglycemic influence of aqueous extract of Ocimum basilicum seeds (AEOBS) in Streptozotocin (STZ) induced diabetic rats and estimating its potential to ameliorate altered level of biochemical parameters, serum electrolytes level and haematological indices along with its effect on body weight of treated rats. The albino rats were selected to observe oral glucose tolerance test by oral intake of aq. glucose solution (4g/kg, body weight) in normal rats and estimation of blood glucose level after administration of AEOBS at 250mg/kg, 500mg/kg and standard drug glibenclamide at 0.6mg/kg, body weight. Antidiabetic activity was evaluated in chronic study models by STZ induced diabetes in rats followed by blood glucose estimation. Chronic study model was selected to carry out further studies to evaluate the effect of AEOBS at 250mg/kg, 500mg/kg and standard drug on body weight, alterations in biochemical parameters including AST, ALT, ALP, total bilirubin and total protein, alterations in serum electrolytes like Na + , K + , Cl - , HCO 3 - along with estimation of haematological indices like red blood cells (RBC), white blood cells (WBC), hemoglobin (Hb), lymphocytes, neutrophils, eosinophils, monocytes and basophils. AEOBS significantly reduced the blood glucose level of diabetic rats at both doses. Body weight was also improved significantly. Similarly, the levels of biochemical parameters, serum electrolytes, and haematological indices were significantly ameliorated at both doses of AEOBS. The histopathological results revealed reconstitution of pancreatic islets towards normal cellular architecture in rats treated with AEOBS. The results illustrated that AEOBS have eminent antidiabetic potential in STZ effectuated diabetes in rats and can be extensively used for the treatment of diabetes mellitus-II and its associated complications including anaemia, diabetic nephropathy, liver dysfunction, and immunosuppression. Copyright © 2016 Elsevier

  20. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  1. Serum zinc values in children with congenital heart disease

    African Journals Online (AJOL)

    EB

    African Health Sciences Vol 13 Issue 3 September 2013. 601. Serum zinc values in .... University Of Benin Teaching Hospital Ethics. Committee. Statistical analysis ..... Felietta J, Mahajan S, McDonald F. Taste acuity and zinc metabolism in ...

  2. New insights into the structure-property relationship of high-voltage electrolyte components for lithium-ion batteries using the pKa value

    International Nuclear Information System (INIS)

    Gallus, Dennis Roman; Wagner, Ralf; Wiemers-Meyer, Simon; Winter, Martin; Cekic-Laskovic, Isidora

    2015-01-01

    In pursuit of higher energy density in lithium-ion batteries (LIBs), a most promising approach focuses on cathode materials that operate at higher potentials and exhibit even higher specific charges than present LIB cathodes charged up to only 3.8 to 4.3 V vs. Li/Li + . To enable a high-voltage (HV) application of the cathode, the “by-materials”, in particular the electrolyte components have to be either thermodynamically or kinetically stable. For this reason, the stability of the electrolyte components towards oxidation, in particular, depending on their HOMO energy levels, is crucial. The theoretical calculation of molecular orbital energies is a helpful and commonly used tool to predict electrochemical stability. Earlier studies demonstrated strong correlation between the HOMO energy and the pK a value, as both depend on electron affinity. Here we report on the first study referring to a pK a value based selection procedure on development of new electrolyte components for the application in lithium-ion batteries. The identified trimethylsilyl(TMS)-based additives, which are known to scavenge HF and show sufficient oxidation stability, enable the application of LiNi 1/3 Co 1/3 Mn 1/3 O 2 (NCM) at an increased upper cut-off potential of 4.6 V vs. Li/Li + without severe degradation, leading to a 50% higher energy density. The use of pK a values is a simple, but highly effective methodology to select appropriate electrolyte components and thus helps to identify functional electrolytes beyond the typical trial and error approach or time-consuming theoretical calculations.

  3. The value of peri-interventional procedure serum bile acid (TBA) detection in patients with primary liver cancer

    International Nuclear Information System (INIS)

    Fan Chen; Liu Yizhi

    2005-01-01

    Objective: To investigate the clinical value of peri-interventional procedure serum bile acid (TBA) detection in patients with primary liver cancer. Methods: The serum TBA was examined peri-operatively in 160 patients with primary liver cancer for testing the correlations between TBA, liver function, the degree of hepatocirrhosis, interventional therapy method and hepatic failure. Results: The preoperative mean value of serum TBA increased significantly in comparing with that of the control group (P<0.01). The preoperative value of serum TBA in different Child grading patients with primary liver cancer were different significantly (P<0.01), Child A< Child B< Child C, the increased degree of serum TBA corresponded with Child grading of the liver function and the cirrhotic degree of liver. In patients with liver function of Child B and C, the postoperative mean values of serum TBA in different interventional therapy methods were different significantly (P<0.01). Comparing with that of the patients without hepatic failure, the postoperative value of serum TBA in the patients with hepatic failure increased significantly (P<0.01). Conclusions: The value of serum TBA can sensitively and accurately reflect liver reserve ability and damage degree of peri-interventional procedure liver function. Hepatic failure can be detected in time and the prognosis of the patients with primary liver cancer can be predicted by testing the value of serum TBA continually. (authors)

  4. Fluid and electrolyte balance during the first week of life and risk of bronchopulmonary dysplasia in the preterm neonate

    Directory of Open Access Journals (Sweden)

    Gustavo Rocha

    2010-01-01

    Full Text Available BACKGROUND: Early fluid and electrolyte imbalances may be associated with an increased risk of bronchopulmonary dysplasia. OBJECTIVE: We sought to establish an association between fluid and electrolyte balance in the first week of life and the risk of bronchopulmonary dysplasia. METHODS: Clinical charts of 205 neonates <32 weeks gestational age and/or <1,250 g birth weight (admitted to our NICU between 1997 and 2008 were analyzed. Clinical features, fluid and electrolyte balance were analyzed for the first 7 days of life using multivariate models of generalized estimation equations. A p value <0.05 was considered significant in all of the hypothesis tests. RESULTS: The prevalence of bronchopulmonary dysplasia was 22%. Lower gestational age and birth weight, male gender, less frequent use of antenatal steroids, respiratory distress syndrome, use of surfactant, patent ductus arteriosus, duration of invasive ventilation and NICU stay were significantly associated with bronchopulmonary dysplasia. The variation in serum values of potassium, phosphorus and creatinine during the first week of life also revealed an association with bronchopulmonary dysplasia. Higher mean plasma calcium values were associated with spontaneous closure of the patent ductus arteriosus. The use of indomethacin to induce patent ductus arteriosus closure was significantly higher in bronchopulmonary dysplasia patients. CONCLUSIONS: Differences in renal function and tubular handling of potassium and phosphorus are present during the first week of life among preterm neonates who will develop bronchopulmonary dysplasia. The higher rate of patent ductus arteriosus and indomethacin use may influence these differences. Serum levels of calcium also appear to play a role in spontaneous ductus arteriosus closure.

  5. The Effect of Percutaneous Nephrolithotomy Process on Hemodynamic, Electrolyte and Acid-Base Changes

    Directory of Open Access Journals (Sweden)

    Ercan Baş

    2015-10-01

    Full Text Available Aim: Operation of percutaneous nephrolithotomy (PNL, is the most commonly used method of renal stone surgery. During this operation, kidney must be continually irrigated with isotonic liquid. In our study, we investigated the volume of irrigation, irrigation duration, input the number of percutaneous renal parenchymal thickness and the degree of this finding the effects of on hemodynamic, electrolyte and metabolic changes. Method: 64 patient with an indication for percutaneous nephrolithotomy were included in the study. Before irrigation, during irrigation and the post- irrigation; pulse, systolic and diastolic blood pressure (bp, electrolytes, arterial blood gases were measured. In preoperative and postoperative 1. and 24. hours hemoglobin, creatinine levels were measured. Before the operation; pelvicaliectasis degree, parenchymal thickness, volume and duration of irrigation and the number of percutaneous entry were recorded in all patients. Results: Following the start of irrigation, changes in diastolic and systolic bp and pulse also not statistically significant. No significant change of partial oxygen, carbon dioxide, and oxygen saturation pressure was observed. After the operation, serum sodium, potassium, calcium values are within normal limits, but when compared with preoperative values the decrease of these values statistically significant were observed. Bicarbonate and ph values with irrigation period had a negative correlation. Although not clinically significant parenchymal thickness was found to be negative correlation with decrease of calcium. Additionally degrees of pelvicaliectasis has been found negative correlation with the decrease of sodium and bicarbonate. Conclusion: Hemodynamics and electrolytes did not change significantly both during and after the PNL process, but metabolic acidosis was observed towards the end of the PNL process. In long-term irrigation, repeated percutaneous entrances, people with moderate and severe

  6. The association of osteopenia with levels of serum 25-hydroxyvitamin D and HOMA-IR values.

    Science.gov (United States)

    Yoldemir, T; Yavuz, D G

    2014-06-01

    To determine the association of osteopenia with levels of serum 25-hydroxyvitamin D and HOMA-IR values in postmenopausal women. Methods One hundred healthy postmenopausal women were included in a cross-sectional study. Venous blood was collected after an overnight fast and 25-hydroxyvitamin D, glucose and insulin levels were measured. HOMA-IR was calculated. Bone mineral density was measured with a dual X-ray absorptiometer. There was no difference in serum 25-hydroxyvitamin D levels and HOMA-IR values between the two groups. A weak positive correlation between serum 25-hydroxyvitamin D levels and osteopenia was detected. Insulin resistance had a weak negative association with osteopenia. The correlations between osteopenia and serum 25-hydroxyvitamin D levels and HOMA-IR values were weak among early postmenopausal women.

  7. The value of serum Hepatitis B surface antigen quantification in ...

    African Journals Online (AJOL)

    The value of serum Hepatitis B surface antigen quantification in determining viralactivity in chronic Hepatitis B virus infection. ... ofCHB andalso higher in hepatitis e antigen positive patients compared to hepatitis e antigen negative patients.

  8. Physicochemistry of the plasma-electrolyte solution interface

    International Nuclear Information System (INIS)

    Chen Qiang; Saito, Kenji; Takemura, Yu-ichiro; Shirai, Hajime

    2008-01-01

    The atmospheric rf plasma discharge was successfully investigated using NaOH or HCl electrolyte solutions as a counter electrode at different pH values. The emission intensities of solution components, self bias, and electron density strongly depend on the pH value of electrolyte. An addition of ethanol to the electrolyte solutions enhanced the dehydration, which markedly promoted the emissions of solution components as well as electrons from the solution. An acidification of the solution was always observed after the plasma exposure and two coexisting mechanisms were proposed to give a reasonable interpretation. The plasma-electrolyte interface was discussed based on a model of hydrogen cycle

  9. Pre- and post-operative values of serum CRP in patients undergoing surgery for brain tumour

    International Nuclear Information System (INIS)

    Syeda, T.; Rizvi, H.A.; Hashim, A.S.

    2014-01-01

    Objective: To determine the concentration of C-reactive protein in pre- and post-operative serum samples of brain tumour patients in order to detect the potential risks of post-operative infections. Methods: Serum C-reactive protein was measured on pre- and post-operative Day 1, Day 2 and Day 7 in 18 patients who underwent surgery for brain tumours. The study was performed at the Neurosurgical Ward, Jinnah Postgraduate Medical Centre, Karachi, from May 2007 to April 2008. Mean pre-operative patients and control values were compared using Mann-Whitney or Wilcoxon tests for comparing between pre- and post-operative values. P-value was considered significant at 5.0mg/L but no statistically significant difference was found when compared with healthy controls, with mean 4.4+-6.6 and 0.9+-0.7, respectively. Significantly raised serum concentrations were observed in all post-operative samples when compared with pre-operative samples. Serum CRP concentrations significantly increased post-operatively on Day 1, with mean value of 102.9+-82.0mg/L (p<0.0005), and further increased on Day 2 with mean value of 166.9+-128.1mg/L (p<0.0005), but declined on Day 7, with mean value of 42.7+-63.6mg/L (p<0.005). Conclusion: Pre-operative serum C-reactive protein concentrations of 28% of the patients were elevated, suggesting an association with brain tumours. Post-operative serum concentrations were significantly higher than those noted before the surgery. Absence of a fall of concentration from peak value on post-operative Day 2 or a secondary rise from post-operative Day 7 could be alarming for inter-current infection. (author)

  10. Electrolytic preparation of sup(99m)Tc human serum albumin using tin electrodes

    International Nuclear Information System (INIS)

    Narasimhan, D.V.S.; Mani, R.S.

    1975-01-01

    A method for labelling human serum albumin [HSA] with sup(99m)Tc using electrolytically generated Sn/II/ ions has been developed. The procedure uses Sn electrodes for electrolysis and gives high labelling yields. The amount of Sn released into the final product was found to be much less than the reported toxic levels. A ready-to-use kit for obtaining sterile sup(99m)Tc HSA is described. Tin metal wires sealed in aluminium were irradiated in a CIRUS reactor at a neutron flux of 7.5x10 12 n cm -2 sec -1 for one month. The 113 Sn produced in the wire was used for tracer studies with the electrolitically labelled HSA. sup(99m)Tc in the form sodium pertechnetate in 0.9% NaCl was obtained by methyl ethyl ketone extraction from alkaline solutions of neutron irradiated 99 Mo [specific activity 50-200 mCi/g] in the solvent extraction generator developed at Isotope Division, BARC. Radiochemical purity analysis of sup(99m)Tc labelled HSA prepared by the above procedure was carried out by ascending paper chromatography on Whatman No.1 paper, and 85% methanol and 0.9% sodium chloride as solvents. (F.Gy.)

  11. SERUM ELECTROLYTES AND ENZYMES IN ENDOMETRITIC NILI-RAVI BUFF ALOES OF TWO AGE GROUPS AND AT TWO STAGES OF LACTATION

    Directory of Open Access Journals (Sweden)

    A. Sarwar, R. U. Shahid, S. Masood, R. Kausar and S. G. Sha

    2002-04-01

    Full Text Available Serum concentrations of tour electrol~1es including sodium (Na, potassium (K, calcium (Ca and Chloride ( Cl and activities of two enzymes i.e. aspartate transaminase ( AST and alanine transaminase (ALT were compared amongst 80 pregnant Nili-Ravi buffaloes in a 23 factorial experiment: between endometritic and health~ lots of two age groups and at two stages of lactation. The analysis of variance revealed that: endometritic buffaloes showing muco-purulent vaginal discharge exhibited raise in ALT, AST and Cl, while decline in Ca. Milking stage affected two parameters namely, serum Cl and AL T. Both Cl and ALT were found to be decreased up to 11 months of lactation. Age groups remained inert on all of the parameters studied. This data indicates that electrolytes and enzymes clearly deviate from their normal levels in endometritic buffaloes which may in turn affect reproductive performance negatively. Thus maintenance of optimal uterine health and balanced nutrition, particularly with reference to blood constituents are critical for better reproductive performance in animals of this species.

  12. The clinical value of detection of serum TGAb and TPOAb level in autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Min Xiaoxia; Huang Xingming

    2008-01-01

    To study the clinical value of serum TGAb and TPOAb levels in the diagnosis of patients with autoimmune thyroid diseases (AITD), the serum levels of TGAb and TPOAb in 175 patients with AITD and 64 non-AITD patients and 57 health controls were measured by RIA. The results showed that the serum levels of TGAb and TPOAb in AITD patients with GD and HT were significantly higher than that of control group (P 0.05). The detection of serum TGAb and TPOAb levels may have clinical value in the diagnosis, treatment and prognosis of autoimmune thyroid diseases. (authors)

  13. Effect of Hibiscus sabdariffa on blood pressure and electrolyte ...

    African Journals Online (AJOL)

    2015-02-27

    Feb 27, 2015 ... as first‑line antihypertensive drug. ... BP, serum, and urine electrolytes were .... The filtrates were stored in clean plastic containers ... Urine samples were collected and Na+, K+ and Cl− were ..... in order to avoid its abuse.

  14. Age-specific reference values for serum FSH and estradiol levels throughout the reproductive period.

    Science.gov (United States)

    Grisendi, Valentina; Spada, Elena; Argento, Cindy; Plebani, Maddalena; Milani, Silvano; Seracchioli, Renato; Volpe, Annibale; La Marca, Antonio

    2014-06-01

    High serum day 3 FSH levels are associated with poor ovarian reserve and reduced fertility, but the interpretation of FSH values according to age is still not univocal. The purpose of this study was to determine age-dependent reference values in women with regular menstrual cycles and FSH as a guide for specialists. The study was performed at the Department of Mother-Infant of a University-based tertiary care centre. One-hundred ninety-two healthy normal menstruating women were recruited for the study. All patients attended the department on menstrual cycle day 3 for a blood sample for FSH and estradiol determination. A linear relationship between FSH or estradiol serum levels and age was observed. The FSH level increased by 0.11 IU for every year of age (1 IU for every 9 years of age). The values of FSH and estradiol corresponding to the 5th, 25th, 50th, 75th, 95th centiles for any specific age have been calculated. Serum FSH levels need to be interpreted according to age-dependent reference values. Serum FSH levels on 95th centile for any age may represent a warning sign for reduced ovarian reserve.

  15. Evaluation of the effect of bolus administration of 50% dextrose solution on measures of electrolyte and energy balance in postpartum dairy cows.

    Science.gov (United States)

    Wagner, Sarah A; Schimek, Daniel E

    2010-09-01

    To determine the effect of IV administration of a bolus of 50% dextrose solution on electrolyte and energy balance and effect of blood collection site on serum electrolyte values in postparturient dairy cows. 24 clinically normal multiparous cows. A bolus of 50% dextrose solution (0.5 L [n=8 cows]), 50% dextrose solution (1.0 L [8]), or saline (0.9% NaCl) solution (1.0 L, control treatment [8]) was administered via jugular venipuncture 5 to 10 days after parturition. Pretreatment and posttreatment blood samples were analyzed for concentrations of calcium, magnesium, phosphorus, potassium, glucose, insulin, beta-hydroxybutyric acid (BHBA), and nonesterified fatty acids. Coccygeal vessel and jugular vein blood samples were obtained prior to treatment, and electrolyte concentrations were compared. Treatment with 50% dextrose decreased phosphorus concentration in serum, compared with the control treatment. Suppression of BHBA and nonesterified fatty acid concentrations following dextrose treatment lasted for dextrose solution may be at risk for hypophosphatemia, and 1 treatment with 0.5 or 1 L of 50% dextrose solution is unlikely to prevent or resolve acetonemia (ketosis). The risk of hypophosphatemia may be underestimated when coccygeal vessel blood samples are used for diagnosis.

  16. Operating mechanisms of electrolytes in magnesium ion batteries: chemical equilibrium, magnesium deposition, and electrolyte oxidation.

    Science.gov (United States)

    Kim, Dong Young; Lim, Younhee; Roy, Basab; Ryu, Young-Gyoon; Lee, Seok-Soo

    2014-12-21

    Since the early nineties there have been a number of reports on the experimental development of Mg electrolytes based on organo/amide-magnesium chlorides and their transmetalations. However, there are no theoretical papers describing the underlying operating mechanisms of Mg electrolytes, and there is no clear understanding of these mechanisms. We have therefore attempted to clarify the operating mechanisms of Mg electrolytes by studying the characteristics of Mg complexes, solvation, chemical equilibrium, Mg-deposition processes, electrolyte-oxidation processes, and oxidative degradation mechanism of RMgCl-based electrolytes, using ab initio calculations. The formation and solvation energies of Mg complexes highly depend on the characteristics of R groups. Thus, changes in R groups of RMgCl lead to changes in the equilibrium position and the electrochemical reduction and oxidation pathways and energies. We first provide a methodological scheme for calculating Mg reduction potential values in non-aqueous electrolytes and electrochemical windows. We also describe a strategy for designing Mg electrolytes to maximize the electrochemical windows and oxidative stabilities. These results will be useful not only for designing improved Mg electrolytes, but also for developing new electrolytes in the future.

  17. Serum free light chain reference values: a critical approach.

    Science.gov (United States)

    Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario

    2013-05-01

    The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.

  18. Diagnostic accuracy of calculated serum osmolarity to predict dehydration in older people: adding value to pathology laboratory reports.

    Science.gov (United States)

    Hooper, Lee; Abdelhamid, Asmaa; Ali, Adam; Bunn, Diane K; Jennings, Amy; John, W Garry; Kerry, Susan; Lindner, Gregor; Pfortmueller, Carmen A; Sjöstrand, Fredrik; Walsh, Neil P; Fairweather-Tait, Susan J; Potter, John F; Hunter, Paul R; Shepstone, Lee

    2015-10-21

    To assess which osmolarity equation best predicts directly measured serum/plasma osmolality and whether its use could add value to routine blood test results through screening for dehydration in older people. Diagnostic accuracy study. Older people (≥65 years) in 5 cohorts: Dietary Strategies for Healthy Ageing in Europe (NU-AGE, living in the community), Dehydration Recognition In our Elders (DRIE, living in residential care), Fortes (admitted to acute medical care), Sjöstrand (emergency room) or Pfortmueller cohorts (hospitalised with liver cirrhosis). Directly measured serum/plasma osmolality: current dehydration (serum osmolality>300 mOsm/kg), impending/current dehydration (≥295 mOsm/kg). 39 osmolarity equations calculated using serum indices from the same blood draw as directly measured osmolality. Across 5 cohorts 595 older people were included, of whom 19% were dehydrated (directly measured osmolality>300 mOsm/kg). Of 39 osmolarity equations, 5 showed reasonable agreement with directly measured osmolality and 3 had good predictive accuracy in subgroups with diabetes and poor renal function. Two equations were characterised by narrower limits of agreement, low levels of differential bias and good diagnostic accuracy in receiver operating characteristic plots (areas under the curve>0.8). The best equation was osmolarity=1.86×(Na++K+)+1.15×glucose+urea+14 (all measured in mmol/L). It appeared useful in people aged ≥65 years with and without diabetes, poor renal function, dehydration, in men and women, with a range of ages, health, cognitive and functional status. Some commonly used osmolarity equations work poorly, and should not be used. Given costs and prevalence of dehydration in older people we suggest use of the best formula by pathology laboratories using a cutpoint of 295 mOsm/L (sensitivity 85%, specificity 59%), to report dehydration risk opportunistically when serum glucose, urea and electrolytes are measured for other reasons in

  19. The determination of serum vitamin B/sub 12/ values using radioassay

    Energy Technology Data Exchange (ETDEWEB)

    Kariyone, S; Morishita, R; Sato, M; Fujimori, K; Miki, M [Kyoto Univ. (Japan). Faculty of Medicine

    1975-04-01

    Strong and weak points of both the Phadebas B/sub 12/ test kit by Pharmacia Co. Ltd. and the CIS B/sub 12/ kit by CEA Co. Ltd. were examined to determine and evaluated. One strong point was that both of kits were comparatively easy to operate. Another was that they were very accurate if only one pipet was used and it was correctly handled. The error from the fractional infusion of 0.1 ml of /sup 57/Co-B/sub 12/ sample remained within +-1.8%, including the error of measuring radioactivity. The recovery rate of vitamin B/sub 12/ added to the serum was 100+-10%. Close correlation was found between the serum B/sub 12/ values measured by each kit and with a careful procedure almost accurate, highly reproducible values were obtained. It was necessary to further examine the pH of the buffer solution in the Phadebas kit and the conditions of extraction of B/sub 12/ from the serum in the CIS kit. In reading the B/sub 12/ values from the standard curve, it was preferable to perform a logic change B/B/sub 0/ % in the samples and to make a linear standard curve, so that the accuracy of the reading would not be infuluenced by variations in the data. (Kanao, N.).

  20. The effect of ONCE Renal on minerals and electrolytes in predialysis patients with chronic kidney disease.

    Science.gov (United States)

    Satirapoj, Bancha; Prapakorn, Janjira; Punpanich, Dollapas; Pongsuparbchon, Chantima; Supasyndh, Ouppatham

    2016-01-01

    Malnutrition is one common adverse consequence in patients with advanced chronic kidney disease (CKD), and most patients have a lower-than-normal dietary energy intake. The present study was undertaken to examine whether orally administered ONCE Renal formula (ORF) supplement would improve energy intake without minerals and electrolytes disturbances in predialysis patients with CKD. All eligible nondiabetic patients with CKD received ORF supplement for 1 week. Nutrition markers, renal function, and minerals and electrolytes were evaluated before and after supplementing. All patients kept a 3-day food record and were interviewed by a registered dietitian. A total of 29 patients with mean age 64.9±13.3 years were included. Mean estimated glomerular filtration rate was 37.7±12.1 mL/min/1.73 m(2). A significant increase was observed in amount of energy, fat, fiber, calcium, and magnesium intake after 1 week of ORF supplement. Moreover, in comparison with baseline values, the patients displayed decreased dietary protein intake and blood urea nitrogen and increased serum magnesium. However, no significant change was found in renal function, nutritional markers (body weight, prealbumin, albumin, and protein equivalence of total nitrogen appearance), serum calcium, phosphorus, sodium, potassium, and bicarbonate. In patients with CKD, ingestion of ORF was well tolerated and had a positive effect with an increase in dietary energy, fat, and fiber intake, as well as a decreased dietary protein intake. No mineral or electrolyte abnormalities were observed during the study.

  1. Evaluation of preoperative predictive values of serum CA15-3 and ...

    African Journals Online (AJOL)

    Evaluation of preoperative predictive values of serum CA15-3 and CEA within Sudanese ... Sudan Journal of Medical Sciences ... Design and setting: This case control study was conducted in Khartoum Teaching Hospital, Khartoum, Sudan.

  2. The value of combined detection of serum β-HCG and progesterone in diagnosis of early ectopic pregnancy

    International Nuclear Information System (INIS)

    Lu Yanting; Wang Taisong

    2011-01-01

    To explore the value of combined detection of serum β-HCG and P in diagnosis of early ectopic pregnancy and expectant therapeutic efficacy. Serum levels of β-HCG and P of 324 patients with early ectopic pregnancy and 146 normal early pregnant women were determined and compared by RIA, Serum β-HCG and P were compared between before and after treatment. The required time when serum β-HCG and P decreased to the normal rang of the patients treated successfully were observed respectively. The results showed that the serum β-HCG and P value in ectopic pregnancy group were significantly lower than those in intrauterine gestation group (P<0.05). The variation of P was significant between success and failure groups of drug conservative treatment, but β-HCG had no significant difference. The required time when serum P decreased to the normal was significantly less than the serum β-HCG dropped to normal. Combined detection of serum levels of β-HCG and P is an adjunctive method to diagnose early ectopic pregnancy, so it giants opportunity for treatment of early ectopic pregnancy and is of positive clinical application value for observation therapeutic effect and prognosis of the disease. P values may be one of the more important reference index to predict whether conservative treatment is successful or not than β-HCG. (authors)

  3. Solid oxide fuel cells with bi-layered electrolyte structure

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xinge; Robertson, Mark; Deces-Petit, Cyrille; Xie, Yongsong; Hui, Rob; Qu, Wei; Kesler, Olivera; Maric, Radenka; Ghosh, Dave [Institute for Fuel Cell Innovation, National Research Council Canada, 4250 Wesbrook Mall, Vancouver, B.C. V6T 1W5 (Canada)

    2008-01-10

    In this work, we have developed solid oxide fuel cells with a bi-layered electrolyte of 2 {mu}m SSZ and 4 {mu}m SDC using tape casting, screen printing, and co-firing processes. The cell reached power densities of 0.54 W cm{sup -2} at 650 C and 0.85 W cm{sup -2} at 700 C, with open circuit voltage (OCV) values larger than 1.02 V. The electrical leaking between anode and cathode through an SDC electrolyte has been blocked in the bi-layered electrolyte structure. However, both the electrolyte resistance (R{sub el}) and electrode polarization resistance (R{sub p,a+c}) increased in comparison to cells with single-layered SDC electrolytes. The formation of a solid solution of (Ce, Zr)O{sub 2-x} during sintering process and the flaws in the bi-layered electrolyte structure seem to be the main causes for the increase in the R{sub el} value (0.32 {omega} cm{sup 2}) at 650 C, which is almost one order of magnitude higher than the calculated value. (author)

  4. Electrolyte Additives for Phosphoric Acid Fuel Cells

    DEFF Research Database (Denmark)

    Gang, Xiao; Hjuler, H.A.; Olsen, C.A.

    1993-01-01

    , as a fuel-cell performance with the modified electrolytes. Specific conductivity measurements of some of the modified phosphoric acid electrolytes are reported. At a given temperature, the conductivity of the C4F9SO3K-modified electrolyte decreases with an increasing amount of the additive; the conductivity...... of the remains at the same value as the conductivity of the pure phosphoric acid. At a given composition, the conductivity of any modified electrolyte increases with temperature. We conclude that the improved cell performance for modified electrolytes is not due to any increase in conductivity.......Electrochemical characteristics of a series of modified phosphoric acid electrolytes containing fluorinated car on compounds and silicone fluids as additives are presented. When used in phosphoric acid fuel cells, the modified electrolytes improve the performance due to the enhanced oxygen...

  5. HEMATOLOGY, SERUM BIOCHEMISTRY, AND URINALYSIS VALUES IN THE ADULT GIANT PANDA ( AILUROPODA MELANOLEUCA).

    Science.gov (United States)

    Burrell, Caitlin; Zhang, Hemin; Li, Desheng; Wang, Chengdong; Li, Caiwu; Aitken-Palmer, Copper

    2017-12-01

    The giant panda ( Ailuropoda melanoleuca) is a high-profile threatened species with individuals in captivity worldwide. As a result of advances in captive animal management and veterinary medicine, the ex situ giant panda population is aging, and improved understanding of age-related changes is necessary. Urine and blood samples were collected in April and July 2015 and analyzed for complete blood count, serum biochemistry, and biochemical and microscopic urine analysis for all individuals sampled ( n = 7, 7-16 yr of age) from giant panda housed at the China Research and Conservation Centre for the Giant Panda in Bifengxia, Sichuan Province, China. Hematology and serum biochemistry values were similar to those previously reported for giant panda aged 2-20 yr and to Species360 (formerly International Species Information System) values. Urine was overall dilute (urine specific gravity range: 1.001-1.021), acellular, and acidic (pH range: 6-7). This is the first report of hematologic and serum biochemistry, with associated urinalysis values, in the giant panda aged 7-16 yr.

  6. Clinical value of serum vitamin B12 and folate in cerebrovascular disease

    International Nuclear Information System (INIS)

    Zhan Hao; Zhang Yongxue

    2002-01-01

    To study the clinical value of serum vitamin B 12 and folate in cerebrovascular disease, the concentration of serum vitamin B 12 and folate in 32 patients with cerebrovascular disease was measured by radioimmunoassay. The results showed that the changes in folate in all groups were not significant. The content of vitamin B 12 in multi-infarct dementia was markedly lower than that in cerebral infarction and cerebral hemorrhage. Moreover, the level of vitamin B 12 was lower in paralytic patients with muscular strength of grade 0-III. It can be concluded that serum vitamin B 12 level had association with intelligent disorder and paralytic degree

  7. Diagnostic Value of Serum Adenosine Deaminase (ADA) Level for Pulmonary Tuberculosis.

    Science.gov (United States)

    Salmanzadeh, Shokrollah; Tavakkol, Heshmatollah; Bavieh, Khalid; Alavi, Seyed Mohammad

    2015-03-01

    Diagnosis of tuberculosis (TB) is not always easy, thus employing methods with a short duration and acceptable sensitivity and specificity is necessary to diagnose TB. The aim of this study was to investigate the diagnostic value of serum adenosine deaminase (ADA) level for diagnosis of pulmonary tuberculosis. A total of 160 sex and age-matched subjects were included in this study, and were divided to four groups; forty patients with pulmonary tuberculosis (PTB) diagnosed based on the national TB program (NTP), forty patients with non-tuberculosis bacterial pneumonia, forty patients with lung cancer and forty people who were healthy in every respect. Serum adenosine deaminase activity in patients of each group was measured by the Giusti and Galanti calorimetry method using a commercial kit (Diazyme, USA). The ANOVA analysis was used to compare groups for quantitative variables. Mean serum ADA level in the PTB group was clearly higher than the mean serum ADA in the other three groups. Mean serum ADA was 26 IU/L in PTB patients, 19.48 IU/L in patients with pneumonia, 15.8 IU/L in patients with lung cancer, and 10.7 IU/L in the control group (P ADA in patients with PTB sensitivity and specificity was defined as 35% and 91%, respectively. Serum ADA activity with high specificity percentage may be a useful alternative test in restricted resource areas to rule out diagnosis of PTB. However, serum ADA activity is not a useful tool for TB diagnosis.

  8. Effect of a ten-week Nordic Walking exercise program on serum electrolyte concentration and plasma acid-base balance in postmenopausal women with overweight or obesity

    OpenAIRE

    Kałużny, Krystian; Kałużna, Anna; Budzyński, Jacek; Hagner, Wojciech; Kochański, Bartosz; Żukow, Walery; Bronisz, Agata; Hagner‑Derengowska, Magdalena

    2016-01-01

    Kałużny Krystian, Kałużna Anna, Budzyński Jacek, Hagner Wojciech, Kochański Bartosz, Żukow Walery, Bronisz Agata, Hagner‑Derengowska Magdalena. Effect of a ten-week Nordic Walking exercise program on serum electrolyte concentration and plasma acid-base balance in postmenopausal women with overweight or obesity. Journal of Education, Health and Sport. 2016;6(12):353-364. eISSN 2391-8306. DOI http://dx.doi.org/10.5281/zenodo.201929 http://ojs.ukw.edu.pl/index.php/johs/article/view/4065 ...

  9. Blood electrolyte disturbances during severe hypoglycemia in Korean patients with type 2 diabetes.

    Science.gov (United States)

    Kang, Mi Yeon

    2015-09-01

    To investigate abnormalities in blood electrolyte levels during severe hypoglycemia in Korean patients with type 2 diabetes mellitus (T2DM) in a clinical setting. Blood electrolyte levels in adult T2DM patients during severe hypoglycemia were collected from January 1, 2008 to December 31, 2012. Patients who maintained normal serum creatinine and blood urea nitrogen levels were utilized in the study. Severe hypoglycemia was defined as a condition requiring medical assistance, such as administering carbohydrates when serum glucose levels less than 70 mg/dL were observed, in conjunction with other symptoms of hypoglycemia. A total of 1,068 patients who visited the emergency room with severe hypoglycemia were screened, of which 219 patients were included in this study. The incidence of abnormal levels for any electrolyte was 47%. Hypokalemia (type of electrolyte disturbance observed at 21.9%. A decrease in serum potassium levels was associated with decreases in blood glucose levels (r = 0.151, p = 0.025). During severe hypoglycemia, median blood glucose levels, incidence of tachycardia (> 100 beats per minute) and severe hypertension (≥ 180/120 mmHg) were 30 mg/dL (range, 14 to 62) and 35 mg/dL (range, 10 to 69; p = 0.04), 18.8% and 7.2% (p = 0.02), and 20.8% and 10.2% (p = 0.05) in the hypokalemia and normokalemia groups, respectively. During severe hypoglycemia, hypokalemia occurred in 21.9% of T2DM patients and was associated with tachycardia and severe hypertension. Therefore, the results suggest that severe hypoglycemia may increase cardiovascular events in T2DM.

  10. Value of serum TORCH-specific antibody detection in assessment of neonatal jaundice

    Directory of Open Access Journals (Sweden)

    Guang-Hua Dai

    2016-06-01

    Full Text Available Objective: To study the value of serum TORCH-specific antibody detection in assessment of neonatal jaundice. Methods: A total of 70 cases of children with neonatal jaundice were selected as jaundice group, 70 cases of healthy newborn were the control group, and serum serum TORCH-specific antibody content as well as heart function, liver function, kidney function and nerve function indicators were detected. Results: Serum TOX-IgM, RV-IgM, CMV-IgM and HSV-IgM positive rate and content of jaundice group were significantly higher than those of control group; serum CK-MB, cTnI, AST, ALT, Cys-C, RBP, MBP, S100β and NSE content of TORCH-positive children were significantly higher than those of TORCHnegative children, and BDNF, NT-3, NT-4 and NGF content were significantly lower than those of TORCH-negative children; T1WI signal of pallidum MRI of TORCH-positive children was significantly higher than that of TORCH-negative children. Conclusions: Serum TORCHspecific antibodies significantly increase in children with neonatal jaundice and can assess the degree of bilirubin metabolism disorder and the degree of target organ damage.

  11. Stability of zirconia sol in the presence of various inorganic electrolytes

    Directory of Open Access Journals (Sweden)

    Marković Jelena P.

    2013-01-01

    Full Text Available Zirconia sol was prepared from zirconium oxychloride solutions by forced hydrolysis at 102ºC. The prepared sol consisted of almost spherical, monoclinic, hydrated zirconia particles 61 nm in diameter. The stability of zirconia sol in the presence of various inorganic electrolytes (LiCl, NaCl, KCl, CsCl, KBr, KI, KNO3, and K2SO4 was studied by potentiometric titration method. Dependence of the critical concentration of coagulation (CCC on the dispersion pH was determined for all studied electrolytes. The critical coagulation concentration values, for all investigated electrolytes, are lower at higher pH. These values for all 1:1 electrolytes are equal in the range of experimental error. For a given pH value, CCCs of K2SO4 are 3-4 orders of magnitude lower than the corresponding values for 1:1 electrolytes. [Projekat Ministarstva nauke republike Srbije, br. III 45012

  12. The baseline serum value of α-amylase is a significant predictor of distance running performance.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Tarperi, Cantor; La Torre, Antonio; Guidi, Gian Cesare; Schena, Federico

    2015-02-01

    This study was planned to investigate whether serum α-amylase concentration may be associated with running performance, physiological characteristics and other clinical chemistry analytes in a large sample of recreational athletes undergoing distance running. Forty-three amateur runners successfully concluded a 21.1 km half-marathon at 75%-85% of their maximal oxygen uptake (VO2max). Blood was drawn during warm up and 15 min after conclusion of the run. After correction for body weight change, significant post-run increases were observed for serum values of alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, bilirubin, creatine kinase (CK), iron, lactate dehydrogenase (LDH), triglycerides, urea and uric acid, whereas the values of body weight, glomerular filtration rate, total and low density lipoprotein-cholesterol were significantly decreased. The concentration of serum α-amylase was unchanged. In univariate analysis, significant associations with running performance were found for gender, VO2max, training regimen and pre-run serum values of α-amylase, CK, glucose, high density lipoprotein-cholesterol, LDH, urea and uric acid. In multivariate analysis, only VO2max (p=0.042) and baseline α-amylase (p=0.021) remained significant predictors of running performance. The combination of these two variables predicted 71% of variance in running performance. The baseline concentration of serum α-amylase was positively correlated with variation of serum glucose during the trial (r=0.345; p=0.025) and negatively with capillary blood lactate at the end of the run (r=-0.352; p=0.021). We showed that the baseline serum α-amylase concentration significantly and independently predicts distance running performance in recreational runners.

  13. Predictive value of serum Golgi protein 73 for prominent hepatic necroinflammation in chronic HBV infection.

    Science.gov (United States)

    Xu, Zhengju; Shen, Jiankun; Pan, Xingnan; Wei, Meijuan; Liu, Liguan; Wei, Kaipeng; Liu, Lifei; Yang, Huanwen; Huang, Jinfa

    2018-06-01

    As a noninvasive marker, serum alanine aminotransferase (ALT) has limitations, because a large proportion of patients chronically infected with hepatitis B virus (HBV) suffer from severe hepatic necroinflammation, but have normal or mildly elevated ALT. In the present study, we aimed to investigate the potential value of serum Golgi protein 73 (GP73) in predicting significant hepatic necroinflamation among chronic HBV infected patients. A cohort of 497 chronic HBV infected patients was retrospectively recruited. Liver biopsy was performed in all patients and serum GP73 levels were measured by enzyme-linked immunosorbent assay. Serum GP73 increased in parallel with the increase in hepatic necroinflammatory activity grade (r = 0.682) and the stage of liver fibrosis (r = 0.539). The positive correlation of serum GP73 with the degree of hepatic necroinflammatory activity was statistically significant, while serum GP73 with the stage of liver fibrosis was weaker than that with hepatic necroinflammation. Furthermore, serum GP73 levels were significantly greater in patients with normal or mildly elevated ALT and significant hepatic necroinflammation (≥G2) than in patients with minimal to mild hepatic necroinflammation. The sensitivity and specificity of GP73 for the diagnosis of G2 hepatic necroinflammation was 42.35% and 95.0%, respectively, at a cut-off value of 88.38 ng/mL. When the cut-off value was set at 124.76 ng/mL, the sensitivity and specificity of GP73 for the diagnosis of G3 hepatic necroinflammation was 55.56% and 97.29%, respectively. These findings indicate that GP73 holds promise as an important candidate for diagnosing significant hepatic necroinflammation. © 2018 Wiley Periodicals, Inc.

  14. Ultrasonic hydrometer. [Specific gravity of electrolyte

    Science.gov (United States)

    Swoboda, C.A.

    1982-03-09

    The disclosed ultrasonic hydrometer determines the specific gravity (density) of the electrolyte of a wet battery, such as a lead-acid battery. The hydrometer utilizes a transducer that when excited emits an ultrasonic impulse that traverses through the electrolyte back and forth between spaced sonic surfaces. The transducer detects the returning impulse, and means measures the time t between the initial and returning impulses. Considering the distance d between the spaced sonic surfaces and the measured time t, the sonic velocity V is calculated with the equation V = 2d/t. The hydrometer also utilizes a thermocouple to measure the electrolyte temperature. A hydrometer database correlates three variable parameters including sonic velocity in and temperature and specific gravity of the electrolyte, for temperature values between 0 and 40/sup 0/C and for specific gravity values between 1.05 and 1.30. Upon knowing two parameters (the calculated sonic velocity and the measured temperature), the third parameter (specific gravity) can be uniquely found in the database. The hydrometer utilizes a microprocessor for data storage and manipulation.

  15. Trace element determination in fingernails, hair and blood serum in patients with Crohn's disease using neutron activation analysis

    International Nuclear Information System (INIS)

    Buschmann, H.

    1984-01-01

    The determination of trace elements and electrolyte concentrations in blood serum, hair and fingernails of 16 patients with Crohn's disease was carried out by means of instrumental neutron activation analysis. In the serum a significant decline in the zinc content could be registered, while the remaining trace elements remained in the normal range. The parenteral nutrition also showed a zinc deficiency. There was, however, also an iron deficiency. The studies of the hair and fingernails gave the following results: Rubidium and antimony in the normal range; zinc, selenium, iron and cobalt below normal values. (orig./PW) [de

  16. [The value of serum free light chain in differential diagnosis of monoclonal gammopathy of renal significance].

    Science.gov (United States)

    Li, C; Wen, Y B; Li, H; Su, W; Li, J; Cai, J F; Chen, L M; Li, X M; Li, X W

    2017-08-08

    Objective: To investigate the value of serum free light chain (FLC) in differential diagnosis of monoclonal gammopathy of renal significance (MGRS). Methods: Forty-nine hospitalized patients who underwent renal biopsy in Peking Union Medical College Hospital between January 2013 and December 2015 were included. Monoclonal gammopathy was detected by serum protein electrophoresis (SPE), serum immunofixation electrophoresis (IFE), urine IFE and serum FLC. All patients were classified as MGRS ( n =32) and monoclonal gammopathy of undetermined significance (MGUS) ( n =17). Results: Renal lesions in MGRS subgroup included light chain amyloidosis ( n =24, 75.0%), light chain deposition disease ( n =7, 21.9%), and fibrillary glomerulopathy ( n =1, 3.1%). Renal diseases in MGUS subgroup included membranous nephropathy ( n =10), focal segmental glomerulosclerosi (FSGS) ( n =3), diabetic glomerulopathy ( n =1), Henoch-Schonlein purpura nephritis ( n =1), anti-GBM disease concurrent with membranous nephropathy ( n =1) and glomerulomegaly ( n =1). Positive number of SPE, serum IFE, urine IFE and abnormal number of serum FLC ratio in MGRS subgroup were 12, 16, 23 and 30, respectively. Positive number of SPE, serum IFE, urine IFE and abnormal number of serum FLC ratio in MGUS subgroup were 11, 17, 6 and 3, respectively. MGRS and MGUS subgroups differed significantly in positive rate of serum IFE ( P value for MGRS, which was helpful for differential diagnosis of patients who had contraindication to renal biopsy.

  17. Electrochemical testing of suspension plasma sprayed solid oxide fuel cell electrolytes

    Science.gov (United States)

    Waldbillig, D.; Kesler, O.

    Electrochemical performance of metal-supported plasma sprayed (PS) solid oxide fuel cells (SOFCs) was tested for three nominal electrolyte thicknesses and three electrolyte fabrication conditions to determine the effects of electrolyte thickness and microstructure on open circuit voltage (OCV) and series resistance (R s). The measured OCV values were approximately 90% of the Nernst voltages, and electrolyte area specific resistances below 0.1 Ω cm 2 were obtained at 750 °C for electrolyte thicknesses below 20 μm. Least-squares fitting was used to estimate the contributions to R s of the YSZ bulk material, its microstructure, and the contact resistance between the current collectors and the cells. It was found that the 96% dense electrolyte layers produced from high plasma gas flow rate conditions had the lowest permeation rates, the highest OCV values, and the smallest electrolyte-related voltage losses. Optimal electrolyte thicknesses were determined for each electrolyte microstructure that would result in the lowest combination of OCV loss and voltage loss due to series resistance for operating voltages of 0.8 V and 0.7 V.

  18. Alaska Steller sea lion pup serum chemistry and hematology values, 1998-2011

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data were used for an analysis of Steller sea lion pup health and condition by Lander et al. (2013). Serum chemistry and hematological values were measured by...

  19. The potential role of electrolytic hydrogen in Canada

    International Nuclear Information System (INIS)

    Hammerli, M.

    1982-03-01

    The potential role of electrolytic hydrogen in Canada is assessed for the period 1980 to 2025 for large-scale uses only. Present uses of hydrogen, and specifically electrolytic hydrogen, are discussed briefly and hydrogen production processes are summarized. Only hydrogen derived from natural gas, coal, or electrolysis of sater are considered. Cost estimates of electrolytic hydrogen are obtained from a parametric equation, comparing values for unipolar water elecctrklyser technologies with those for bipolar electrolysers. Both by-products of electrolytic hydrogen production, namely heavy water and oxygen, are evaluated. Electrolytic hydrogen, based on non-fossil primary energy sources, is also considered as ankther 'liquid fuel option' for Canada along with the alcohols. The market potential for hydrogen in general and electrolytic hydrogen is assessed. Results show that the market potential for electrolytic hydrogen is large by the year 2025

  20. Response behaviour of oxygen sensing solid electrolytes

    NARCIS (Netherlands)

    Winnubst, Aloysius J.A.; Scharenborg, A.H.A.; Burggraaf, A.J.

    1985-01-01

    The response time (t r) after a step change in oxygen partial pressure was investigated for some solid electrolytes used in Nernst type oxygen sensors. The electrolyte as well as the (porous) electrode material affect the value oft r. Stabilized Bi2O3 materials exhibit slower response rates (largert

  1. Physics of failure based analysis of aluminium electrolytic capacitor

    International Nuclear Information System (INIS)

    Sahoo, Satya Ranjan; Behera, S.K.; Kumar, Sachin; Varde, P.V.; Ravi Kumar, G.

    2016-01-01

    Electrolytic capacitors are one of the important devices in various power electronic systems, such as motor drives, uninterruptible power supply, electric vehicles and dc power supply. Electrolytic capacitors are also the integral part of many other electronic devices. One of the primary function of electrolytic capacitors is the smoothing of voltage ripple and storing electrical energy. However, the electrolytic capacitor has the shortest lifespan of components in power electronics. Past experiences show that electrolytic capacitor tends to degrade and fail faster under high electrical or thermal stress conditions during operations. The primary failure mechanism of an electrolytic capacitor is the evaporation of the electrolyte due to electrical or thermal overstress. This leads to the drift in the values of two important parameters-capacitance and equivalent series resistance (ESR) of the electrolytic capacitor. An attempt has been made to age the electrolytic capacitor and validate the results. The overall goal is to derive the accurate degradation model of the electrolytic capacitor. (author)

  2. Lipid Peroxidation and Electrolytes in Irradiated Rats Treated with Caffeine

    International Nuclear Information System (INIS)

    Abdel-Gawad, I.I.; Ahmed, A.M.

    2005-01-01

    This Study was conducted to elarify the potential role of caffeine (1,3,7-trimethyl xanthine), a major component of coffee, against damages induced by gamma rays. Thirty adult female albino rats (130+10) were divided into three groups, each of ten animals. The first group acted as control animals. The second was sujected to a single dose of (7) Gy whole body gamma irradiation. The third group was injected intraperitoneally with a single dose (80mg/kg body weight) of caffeine one-hour prior irradiation. Blood samples were collected five time intervals 1,3,7,15 and 30 days post-irradiation. The content of serum lipid peroxides was measured as thiobarbituric acid reactive substance (TBARS). Electrolytes as calcium (Ca2 + ), sodium (Na + ) and potassium (K + ) and levels were estimated and Na + /K + ratio was calculated. Also serum enzymes as alkaline phosphatase (ALP) and aminotransaminases (AST and ALT) activity levels were measured. The data revealed significant increase in TBARS, AST and ALT levels in serum due to irradiation exposure. While, radiation induced significant decrease in serum level of ALP, level of electrolytes Ca 2+ , Ma + , and Na + /K + ratio. On the other hand, group injected intraperitoneally with caffeine pre-irradiation exhibited reduction in the changes produced by gamma-radiation with variable degree. The data showed that this antioxidant confers protection damage inflicted by radiation when given prior to irradiation exposure on the examined parameters

  3. Nanoporous hybrid electrolytes

    KAUST Repository

    Schaefer, Jennifer L.

    2011-01-01

    Oligomer-suspended SiO2-polyethylene glycol nanoparticles are studied as porous media electrolytes. At SiO2 volume fractions, , bracketing a critical value y ≈ 0.29, the suspensions jam and their mechanical modulus increase by more than seven orders. For >y, the mean pore diameter is close to the anion size, yet the ionic conductivity remains surprisingly high and can be understood, at all , using a simple effective medium model proposed by Maxwell. SiO 2-polyethylene glycol hybrid electrolytes are also reported to manifest attractive electrochemical stability windows (0.3-6.3 V) and to reach a steady-state interfacial impedance when in contact with metallic lithium. © 2010 The Royal Society of Chemistry.

  4. Pretreatment of enteral nutrition with sodium polystyrene sulfonate: effective, but beware the high prevalence of electrolyte derangements in clinical practice.

    Science.gov (United States)

    Le Palma, Krisha; Pavlick, Elisha Rampolla; Copelovitch, Lawrence

    2018-04-01

    Current treatment options for chronic hyperkalemia in children with chronic kidney disease include dietary restrictions or enteral sodium polystyrene sulfonate (SPS); however, dietary restrictions may compromise adequate nutrition and enteral SPS may be limited by palatability, adverse effects and feeding tube obstruction. A potentially safer alternative is to pretreat enteral nutrition (EN) with SPS prior to consumption. The purpose of this study was to evaluate the efficacy and safety of pretreating EN with SPS in pediatric patients with hyperkalemia. We performed a retrospective cohort study between September 2012 and May 2016 at the Children's Hospital of Philadelphia. In all, 14 patients (age range 0.5-53.2 months) who received 19 courses of SPS pretreatment of EN were evaluated. Serum electrolytes were evaluated at baseline and within 1 week of initiating therapy. The primary endpoint was mean change in potassium at 7 days. Secondary endpoints included the mean change in serum sodium, chloride, bicarbonate, calcium, phosphorous and magnesium, as well as the percentage of patients who developed electrolyte abnormalities within the first week of treatment. Serum potassium levels decreased from 6.0 to 4.4 mmol/L (P < 0.001) and serum sodium levels increased from 135.8 to 141.3 mmol/L (P = 0.008) 1 week after initiating SPS pretreatment. No significant differences in mean serum calcium or magnesium levels were noted. Nevertheless, more than half of the courses resulted in at least one electrolyte abnormality, with hypokalemia (31.6%), hypernatremia (26.3%) and hypocalcemia (21.1%) occurring most frequently. Pretreatment of EN with SPS is an effective method for treating chronic hyperkalemia in pediatric patients; however, close monitoring of electrolytes is warranted.

  5. Effect of a ten-week Nordic Walking exercise program on serum electrolyte concentration and plasma acid-base balance in postmenopausal women with overweight or obesity.

    Directory of Open Access Journals (Sweden)

    Krystian Kałużny

    2016-12-01

    Patients and methods: The subjects were 32 postmenopausal women with overweight or obesity were studied. Before the start of the exercise program and directly after it had finished, blood samples were taken to determine sodium, potassium, magnesium, calcium, phosphorus, and capillary gasometry parameters. Results: After the 10-week exercise program, a significant decrease in serum concentrations of sodium, magnesium, calcium, capillary potential of hydrogen (pH, capillary partial pressure of carbon dioxide (pCO2, bicarbonate (HCO3, and base excess (BE, as well as an increase in potassium, chloride, capillary partial pressure of oxygen (pO2, and hemoglobin oxygen saturation  (SaO2 levels was found. The proportional change in sodium serum concentrations correlated significantly with delta BMI, and potassium and calcium proportional alterations after the exercise program had finished correlated with proportional changes in albumin concentration. Conclusions: A 10-week Nordic Walking exercise program resulted in statistically significant changes in almost all serum electrolyte concentration, but only to a small extent and probably without clinical importance. The improvement in oxygen partial pressure in capillary blood after the exercise program shows a potentially complex, favorable effect of a prolonged exercise program and requires further study.     Keywords: Nordic Walking, exercise physiology, physical activity, obesity, aging.

  6. Electrode-electrolyte BIMEVOX system for moderate temperature oxygen separation

    Energy Technology Data Exchange (ETDEWEB)

    Boivin, J.C.; Pirovano, C.; Nowogrocki, G.; Mairesse, G. [Laboratoire de Cristallochimie et Physicochimie du Solide, URA CNRS 452, USTL-ENSCL BP 108, 59652 Villeneuve d`Ascq (France); Labrune, Ph.; Lagrange, G. [Centre de recherches Claude Delorme, Air Liquide, Jouy en Josas (France)

    1998-12-01

    Electrochemical separation of oxygen from air is a promising application for oxide conductor solid electrolytes. However, several important specifications are required in order to obtain an efficient separation device. First of all, the electrolyte material must exhibit a high conductivity at moderate temperature. From this point of view, a new family of materials called BIMEVOX ideally fulfils this condition. Secondly, a typical separation device must comport two electrodes on opposite faces of the electrolyte. These electrodes must act as electronic collectors but also, at the cathodic side, as an oxygen dissociation catalyst. BIMEVOX electrolytes exhibit ionic conductivity values that can allow work at temperature below 500C. The classical electrode approach, like in solid oxide fuel cells, consists in using a specific mixed oxide, for instance strontium lanthanum manganite or cobaltite. However, the lower the temperature, the lower the efficiency of these electrodes which quickly appears as the limiting factor. In previous work on bismuth lead oxide electrolytes, we proposed a new approach that consists of using the surface of the bismuth-based electrolyte itself as the catalyst, the electron collection being then performed by a co-sintered metallic grid. This `in-situ` electrode system provides many advantages, particularly it eliminates the problem of the chemical compatibility between electrode and electrolyte materials. Taking into account the presence of both catalytic vanadium and bismuth cations in BIMEVOX, we checked under these conditions the separation of oxygen from air for different electrolytes (BICOVOX, BICUVOX, BIZNVOX) at various temperatures in the range 430-600C. For instance, using a BICOVOX pellet with a gold grid inserted on each side makes it possible to separate oxygen with nearly 100% efficiency for current density values up to 1000 mA/cm{sup -2}. For higher intensity values, the faradic efficiency progressively but reversibly decreases

  7. The clinical value of serum thyrotrophin receptor antibody level in patients with Graves ophthalmopathy

    International Nuclear Information System (INIS)

    Wang Chaodian; Shi Yuhong; Yan Bing

    2013-01-01

    Objective: To explore the value of serum thyrotrophin receptor antibody (TRAb) on the pathological mechanism of Graves ophthalmopathy. Methods: Two hundred and nineteen newly diagnosed Graves disease patients who were divided into Graves ophthalmopathy group (n=121) and without Graves ophthalmopathy group (n=98) were tested serum concentration with thyroid function, thyroperoxidase antibodies (TPOAb), thyroglobulin antibodies (TgAb) and TRAb. According to the consensus statement of the European Group on Graves ophthalmopathy, clinical activity score (CAS) and severity evaluation were carried out on Graves ophthalmopathy patients. Results: There was no significant difference in serum concentration of free thyroxine (FT 4 ), free triiodothyronine (FT 3 ), TPOAb and TRAb between the Graves ophthalmopathy group and the without Graves ophthalmopathy group. Serum concentration of TRAb was not correlated with the severity and CAS of Graves ophthalmopathy. Conclusions: The CAS and the severity of Graves ophthalmopathy were irrelevant to the serum concentration of TRAb. Therefore, the correlation between TRAb and Graves ophthalmopathy still needs further study. (authors)

  8. Prognostic Value of Serum Free Light Chain in Multiple Myeloma.

    Science.gov (United States)

    El Naggar, Amel A; El-Naggar, Mostafa; Mokhamer, El-Hassan; Avad, Mona W

    2015-01-01

    The measurement of serum free light chain (sFLC) has been shown to be valuable in screening for the presence of plasma cell dyscrasia as well as for baseline prognosis in newly diagnosed patients. The aim of the present work was to study the prognostic value of sFLC in multiple myeloma in relation to other serum biomarkers, response to therapy and survival. Forty five newly diagnosed patients with MM were included in the study. Patients were divided into responders and non-responders groups according to response to therapy. sFLC and serum Amyloid A (SAA) were measured by immunonephelometry. The non-responders group showed a statistically significant higher kappa/lambda or lambda/kappa ratio and higher β2 microglobulin level, but lower albumin level at presentation, as compared to the responders group (P < 0.001). However, no statistically significant difference was detected between the two groups regarding SA A or calcium levels. Comparison between sFLC ratio obtained before and after therapy revealed significant decrease after treatment in the responders group (P = 0.05). Survival was significantly inferior in patients with an FLC ratio of ≥ 2.6 or ≤ 0.56 compared with those with an FLC ratio that was between 0.56 and 2.6 (P = 0.002).

  9. SERUM ELECTROLYTES IN BUFFALOES DURING LATE PREGNANCY, PARTURITION AND POST PARTUM PERIODS

    Directory of Open Access Journals (Sweden)

    Shahzad Hussain, Muhammad Amir Saeed and Isma Nazli Bashir

    2001-09-01

    Full Text Available This study was executed on 30 pregnant Nili-Ravi buffaloes. Serum was harvested for the estimation of calcium, magnesium, phosphorus, sodium, potassium and iron in the late pregnancy (at 8th and 9th month of gestation, at parturition and in the postpartum periods (at Ist and 2 month postpartum. The concentrations of Ca and P were significantly (P< 0.05 lower and Mg was significantly (P<0.05 higher at the time of parturition. The concentrations of Na and K did not show much variation. The values of Fe also decreased significantly (P<0.05 near parturition (at 9th month of gestation and at parturition. No puerperal disorder was observed in any of the experimental animals.

  10. Electrolyte for batteries with regenerative solid electrolyte interface

    Science.gov (United States)

    Xiao, Jie; Lu, Dongping; Shao, Yuyan; Bennett, Wendy D.; Graff, Gordon L.; Liu, Jun; Zhang, Ji-Guang

    2017-08-01

    An energy storage device comprising: an anode; and a solute-containing electrolyte composition wherein the solute concentration in the electrolyte composition is sufficiently high to form a regenerative solid electrolyte interface layer on a surface of the anode only during charging of the energy storage device, wherein the regenerative layer comprises at least one solute or solvated solute from the electrolyte composition.

  11. Clinical value of serum anti-mullerian hormone and inhibin B in prediction of ovarian response in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Zhang, Fan; Liu, Xiao-Ling; Rong, Nan; Huang, Xiao-Wen

    2017-02-01

    The present study aimed to investigate the clinical value of serum anti-mullerian hormone (AMH) and inhibin B (INHB) in predicting the ovarian response of patients with polycystic ovary syndrome (PCOS). A total of 120 PCOS patients were enrolled and divided into three groups in terms of the ovarian response: a low-response group (n=36), a normal-response group (n=44), and a high-response group (n=40). The serum AMH and INHB levels were measured by enzyme-linked immunosorbent assay (ELISA). The follicle stimulating hormone (FSH), luteinizing hormone (LH), and estradiol (E2) levels were determined by chemiluminescence microparticle immunoassay. The correlation of the serum AMH and INHB levels with other indicators was analyzed. A receiver operating characteristic (ROC) curve was established to analyze the prediction of ovarian response by AMH and INHB. The results showed that there were significant differences in age, body mass index (BMI), FSH, total gonadotropin-releasing hormone (GnRH), LH, E2, and antral follicle counts (AFCs) between the groups (Povarian response of PCOS patients increasing (Povarian response showed that the area under the ROC curve (AUC) value of the serum AMH level was 0.817, with a cut-off value of 1.29 ng/mL. The sensitivity and specificity were 71.2% and 79.6%, respectively. The AUC value of serum INHB was 0.674, with a cut-off value of 38.65 ng/mL, and the sensitivity and specificity were 50.7% and 74.5%, respectively. ROC curve analysis showed when the serum AMH and INHB levels were used to predict a high ovarian response, the AUC value of the serum AMH level was 0.742, with a cut-off value of 2.84 ng/mL, and the sensitivity and specificity were 72.7% and 65.9%, respectively; the AUC value of the serum INHB level was 0.551 with a cut-off of 45.76 ng/mL, and the sensitivity and specificity were 76.3% and 40.2%, respectively. It was suggested the serum AMH and INHB levels have high clinical value in predicting the ovarian response of PCOS

  12. The effect of ONCE Renal on minerals and electrolytes in predialysis patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Satirapoj B

    2016-04-01

    Full Text Available Bancha Satirapoj,1 Janjira Prapakorn,2 Dollapas Punpanich,2 Chantima Pongsuparbchon,3 Ouppatham Supasyndh11Division of Nephrology, Department of Medicine, 2Research Unit, Department of Medicine, 3Clinical Research Center, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, ThailandBackground: Malnutrition is one common adverse consequence in patients with advanced chronic kidney disease (CKD, and most patients have a lower-than-normal dietary energy intake. The present study was undertaken to examine whether orally administered ONCE Renal formula (ORF supplement would improve energy intake without minerals and electrolytes disturbances in predialysis patients with CKD.Methods: All eligible nondiabetic patients with CKD received ORF supplement for 1 week. Nutrition markers, renal function, and minerals and electrolytes were evaluated before and after supplementing. All patients kept a 3-day food record and were interviewed by a registered dietitian.Results: A total of 29 patients with mean age 64.9±13.3 years were included. Mean estimated glomerular filtration rate was 37.7±12.1 mL/min/1.73 m2. A significant increase was observed in amount of energy, fat, fiber, calcium, and magnesium intake after 1 week of ORF supplement. Moreover, in comparison with baseline values, the patients displayed decreased dietary protein intake and blood urea nitrogen and increased serum magnesium. However, no significant change was found in renal function, nutritional markers (body weight, prealbumin, albumin, and protein equivalence of total nitrogen appearance, serum calcium, phosphorus, sodium, potassium, and bicarbonate.Conclusion: In patients with CKD, ingestion of ORF was well tolerated and had a positive effect with an increase in dietary energy, fat, and fiber intake, as well as a decreased dietary protein intake. No mineral or electrolyte abnormalities were observed during the study.Keywords: oral-specific renal nutrition, malnutrition

  13. 早产儿出生第1天的血电解质及肾功能测量值分析%Investigating the Serum Electrolyte and Renal Function Measured Values in Premature Infants Born in the First Day

    Institute of Scientific and Technical Information of China (English)

    吕少广; 刘芳; 杜志方; 郭志梅; 周春风

    2013-01-01

    目的 了解早产儿出生第1天的血清电解质及肾功能测量值,并与同阶段足月儿上述指标进行比较,探讨临床治疗中的注意事项,以期指导临床工作.方法 调查了2008年6月~2011年6月入住笔者医院新生儿病区的267例新生儿的血清电解质及肾功能测量值,其中极低出生体重(VLBW)早产儿99例,低出生体重(LBW)早产儿115例,足月儿53例,上述患儿均排除了少尿.采用的生化测量仪为日本Olympus AU5400全自动生化测量仪.测定的内容包括血清钾、钠、钙、氯、尿素氮(BUN)、肌酐(CREA).结果 VLBW早产儿和LBW早产儿的平均血清钾、血尿素氮及血肌酐测量值高于足月儿组(P<0.01),平均血清钙测量值低于足月儿组(P<0.01),两组早产儿高钾血症、低钙血症的发生率均高于足月儿组(P<0.01).VLBW早产儿组的平均血清钾、血尿素氮及血肌酐测量值与LBW早产儿组无差异(P>0.05),但VLBW早产儿组的高钾血症的发生率高于LBW早产儿组.VLBW早产儿组平均血清钙测量值低于LBW早产儿组(P<0.01),且低钙血症的发生率高于LBW早产儿组(P<0.01).3组平均血清钠、氯测量值差异无显著意义,(P>0.05).结论 早产儿生后第1天的血钾偏高,同时血清钙偏低,尤其是VLBW早产儿,临床上需要对这一特殊人群出生第1天的血钾、血钙进行动态监测,警惕非少尿型高钾血症和低钙血症的发生.%Objective This paper reported the serum electrolyte and renal function measured values in premature infants born in the first day and compared the measured values with full term infants,discussed clinical considerations in order to guide clinical work.Methods A total of 267 newborn infants admitted to Neonatal Intensive Care Unit from June 2008 to June 2011 were recruited including male 140,female 127,of whom 53 were full-term infants and 214 were preterm infants (99 were very low birth weight infants,115 were low birth weight

  14. Chemical stability of {gamma}-butyrolactone-based electrolytes for aluminium electrolytic capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Ue, Makoto [Mitsubishi Chemical Corp., Tsukuba Research Center, Ibaraki (Japan); Takeda, Masayuki [Mitsubishi Chemical Corp., Tsukuba Research Center, Ibaraki (Japan); Suzuki, Yoko [Mitsubishi Chemical Corp., Tsukuba Research Center, Ibaraki (Japan); Mori, Shoichiro [Mitsubishi Chemical Corp., Tsukuba Research Center, Ibaraki (Japan)

    1996-06-01

    {gamma}-Butyrolactone-based electrolytes have been used as the operating electrolytes for aluminum electrolytic capacitors. The chemical stability of these electrolytes at elevated temperatures has been examined by monitoring the decrease in their electrolytic conductivities. The deteriorated electrolytes were analyzed by gas and liquid chromatography and the conductivity decrease was directly correlated with the loss of acid components. In quaternary ammonium hydrogen maleate/{gamma}-butyrolactone electrolytes, the maleate anion decomposed by decarboxylation resulting in a complex polymer containing polyester and polyacrylate structures. Quaternary ammonium benzoate/{gamma}-butyrolactone electrolytes decomposed by SN2 reactions giving alkyl benzoates and trialkylamines. The deterioration of the carboxylate salt/{gamma}-butyrolactone electrolytes was accelerated by electrolysis. (orig.)

  15. [Diagnostic values of serum type III procollagen N-terminal peptide in type IV gastric cancer].

    Science.gov (United States)

    Akazawa, S; Fujiki, T; Kanda, Y; Kumai, R; Yoshida, S

    1985-04-01

    Since increased synthesis of collagen has been demonstrated in tissue of type IV gastric cancer, we attempted to distinguish type IV gastric cancer from other cancers by measuring serum levels of type III procollagen N-terminal peptide (type III-N-peptide). Mean serum levels in type IV gastric cancer patients without metastasis were found to be elevated above normal values and developed a tendency to be higher than those in types I, II and III gastric cancer patients without metastasis. Highly positive ratios were found in patients with liver diseases including hepatoma and colon cancer, biliary tract cancer, and esophageal cancer patients with liver, lung or bone metastasis, but only 2 out of 14 of these cancer patients without such metastasis showed positive serum levels of type III-N-peptide. Positive cases in patients with type IV gastric cancer were obtained not only in the group with clinical stage IV but also in the groups with clinical stages II and III. In addition, high serum levels of type III-N-peptide in patients with type IV gastric cancer were seen not only in the cases with liver, lung or bone metastasis but also in cases with disseminated peritoneal metastasis alone. These results suggest that if the serum level of type III-N-peptide is elevated above normal values, type IV gastric cancer should be suspected after ruling out liver diseases, myelofibrosis and liver, lung or bone metastasis.

  16. Electrocardiographic abnormalities in acute cerebro-vascular accidents and their correlation with cerebro-spinal fluid pressure and serum electrolytes

    Directory of Open Access Journals (Sweden)

    Gambhir M

    1978-01-01

    Full Text Available Electrocardiographic studies have been carried out in 50 patients with acute cerebrovascular accidents. These cases included 31 cases from non-haemorrhagic group and 19 cases from haemor-rhagic group. `T′ or T-U wave abnormalities were seen in 63.1% of cases in haemorrhagic group and in 35.4% of cases from non-hae-morrhagic group. Abnormal prolongation of QTc interval (105% of normal i.e. 0.45 Secs. was observed in 73.6% cases from haemorrhagic group and in 35.4% of cases from non-haemorrhagic group. On comparing these two groups it was found that QTc was signi-ficantly more prolonged in patiens of haemorrhagic group than non--haemorrhagic group. The CSF pressure was found to be signi-ficantly more in patients with ECG abnormalities. However, there teas no correlation between serum electrolyte levels and ECG abnormalities. After 2 weeks, the ECG abnormalities disappeared, except in two cases from haemorrhagic group. There was no signi-ficant difference in the incidence of mortality between patient having ECG abnormalities and the patients without ECG abnormalities. In the light of these findings the probable mechanism of production of ECG changes in acute cerebrovascular accidents is discussed.

  17. Blood gas and electrolyte values of (Capra hircus Canindé breed goats raised in the northeastern semiarid

    Directory of Open Access Journals (Sweden)

    Talyta Lins Nunes

    2014-09-01

    Full Text Available ABSTRACT. Nunes T.L., Oliveira M.G.C., Paiva A.L.C., Bezerra T.C.G., Barrêto Júnior R.A. & Paula V.V. [Blood gas and electrolyte values of (Capra hircus Canindé breed goats raised in the northeastern semiarid.] Valores hemogasométricos de caprinos (Capra hircus da raça Canindé criados no semiárido nordestino. Revista Brasileira de Medicina Veterinária, 36(3:255-260, 2014. Departamento de Ciências Animais, Universidade Federal Rural do Semi-Árido, BR 110, Km 47, Bairro Presidente Costa e Silva, Mossoró, RN 59625-900, Brasil. E-mail: talyta_lins@hotmail.com Canindé goat breed is native of northeastern Brazil and is in danger of extinction. The objective of this research was to determine blood gas and electrolytes values in Canindé goat breed reared in the state of Rio Grande do Norte, establishing baseline data for the breed in the semi-arid conditions. Blood samples from 83 clinically healthy animals were collected and distributed in four groups: Group I comprised of 32 pregnant females, Group II, 29 non-pregnant, Group III, 10 males, and group IV consisted of 12 pups. The blood sample was submitted for blood gas analysis, determining the concentration of sodium, potassium, chloride, total carbon dioxide, pH, carbon dioxide partial pressure, sodium bicarbonate, excess base, and anion gap. Data with normal distribution were analyzed by ANOVA and Tukey test; those which did not have a normal distribution were analyzed by Kruskal-Wallis, Mann-Whitney and Spearman. The results were expressed as mean and standard deviation. The values obtained were similar to those found in other studies with different goat and sheep breeds, and thus may serve as reference for the Canindé breed. The data suggest an influence of age, sex and reproductive status in the variables analyzed.

  18. Electrolyte creepage barrier for liquid electrolyte fuel cells

    Science.gov (United States)

    Li, Jian [Alberta, CA; Farooque, Mohammad [Danbury, CT; Yuh, Chao-Yi [New Milford, CT

    2008-01-22

    A dielectric assembly for electrically insulating a manifold or other component from a liquid electrolyte fuel cell stack wherein the dielectric assembly includes a substantially impermeable dielectric member over which electrolyte is able to flow and a barrier adjacent the dielectric member and having a porosity of less than 50% and greater than 10% so that the barrier is able to measurably absorb and chemically react with the liquid electrolyte flowing on the dielectric member to form solid products which are stable in the liquid electrolyte. In this way, the barrier inhibits flow or creepage of electrolyte from the dielectric member to the manifold or component to be electrically insulated from the fuel cell stack by the dielectric assembly.

  19. A quest for normal values of serum aminotransferase and its association with age and body mass index

    International Nuclear Information System (INIS)

    Farooq, M.A.; Farooq, Y.; Khan, M.A.

    2016-01-01

    Objective: To determine the reference range for serum alanine aminotransferase (ALT) levels for young healthy individuals in our population and to find out effects of age and body mass index on alanine aminotransferase. Study Design: Descriptive cross sectional study. Place and Duration of Study: Military Hospital Rawalpindi; from Dec 2009 to April 2010. Material and Methods: Five hundred and fifty three young healthy adults were included in the study. Detailed history was taken. Parameters like Age, height and weight were measured. Relevant investigations were carried out for each subject which included blood complete picture, Chest X-Ray, ECG, Urine routine examination, liver function tests, serum urea, serum creatinine, serum uric acid, plasma glucose (F), Anti HCV antibodies, HBsAg, HIV antibodies and VDRL. Data was analyzed using SPSS version 22. Results: Age of subjects ranged from 19 to 50 years (29 +- 6) years, BMI 15.59 to 29.8, (21.58 +- 2). Serum alanine aminotransferase ranged from 17 to 81 IU/l, (29.9 +- 8) IU/l. Serum alanine aminotransferase for subjects with body mass index more than 25 Kg/m2 was 29.6 +- 7 IU/L. There is no significant difference in value of mean ALT overall and in those with BMI of more than 25 (p=0.149) Conclusion: Mean serum alanine aminotransferase value in young healthy adults included in this study was 29.9 +- 8 IU/L which is lower than normal reference provided at present which is 40 IU/l. Statistical analysis revealed that serum ALT is not significantly influenced by age and BMI. (author)

  20. Clinical value of serum TRAb levels determination in diagnosis of Graves's disease

    International Nuclear Information System (INIS)

    Huang Zhaosui; Huang Chunhong; Liu Kaiyuan; Huang Shengli

    2005-01-01

    Objective: To investigate the clinical diagnostic value of serum TRAb levels determination in patients with Graves' disease. Methods: Serum TRAb (with RRA), FT 3 , FT 4 , TSH (with CLIA) levels were measured in 223 patients with Graves' disease both before and 6, 12, 36 months after treatment with antithyroid drugs (ATD) as well as in 50 controls. Results: Positive rate of serum TRAb was 93.3% in patients with Graves' disease before treatment. Six months after ATD therapy the positive rate dropped to 41.3%, being still significantly higher than that in controls (P<0.05). The TRAb positive rate dropped steadily with 12 (18.3% ), 24 (8.9% ) and 36 months (4.9%) of ATD treatment. In the 21 patients who had hyperthyroidism recurred after the course of treatment, TRAb remained positive in 18 of them (80.7%). Conclusion: Persistent positive TRAb despite euthyroid status in patients with Graves' disease after seemingly successful ATD treatment donates persistent immunodysfunction and possible recurrence. It is mandatory to continue ATD treatment until TRAb negative. (authors)

  1. Values of serum AFP, GGTⅡ and GP73 in diagnosis of primary hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    ZHU Chen

    2014-10-01

    Full Text Available ObjectiveTo explore the early diagnostic values of serum alpha-fetoprotein (AFP, gamma-glutamyltransferase Ⅱ (GGTⅡ, and Golgi protein 73 (GP73 in patients with primary hepatocellular carcinoma (PHC. MethodsThe serum specimens of 100 patients with liver diseases (50 cases of hepatitis and liver cirrhosis and 50 cases of PHC and 50 healthy people were collected in our hospital from February 2013 to February 2014. Electrochemical luminescence technique, specific immuno-membrane adsorption assay, and enzyme-linked immunosorbent assay were used to measure the serum levels of AFP, GGTⅡ, and GP73. Comparison of continuous data between multiple groups was made by analysis of variance, and comparison between two groups was made by q test. The receiver operating characteristic (ROC curves of single or combined test results were made, and the areas under the ROC curves (AUCs were calculated. The sensitivity, specificity, and AUCs of AFP, GGTⅡ, GP73, and the combined test were analyzed and compared. ResultsThe level of serum GGTⅡ in the PHC group was significantly different compared with those in the other two groups (F=16.224, P<0.05, but there was no significant difference between the normal group and the hepatitis and liver cirrhosis group (P>0.05. Significant differences in serum levels of AFP and GP73 were observed by paired comparison between the PHC group, hepatitis and liver cirrhosis group, and normal group (F=193.128, F=20.231, P<0.05 for both. When assayed alone, the specificities of GP73, GGTⅡ, and AFP were 69%, 64% and 51%, respectively, and the sensitivities were 92%, 84%, and 76%, respectively. In combined test, the specificity was 94.6% and the sensitivity was 98.8%. ConclusionThe GP73 test is the best performer in the single assays. Combined test of serum AFP, GGTⅡ, and GP73 shows a good diagnostic value for PHC with greatly improved specificity and sensitivity.

  2. Evaluation value of coronary CTA for coronary plaque features and its correlation with platelet function and serum biochemical indexes

    Directory of Open Access Journals (Sweden)

    Jin-Xia Yang

    2017-01-01

    Full Text Available Objective: To analyze the evaluation value of coronary CT angiography for coronary plaque features and its correlation with platelet function and serum biochemical indexes. Methods: A total of 450 patients with coronary heart disease were divided into calcified plaque group (CT value≥130HU (n=117, soft plaque group (CT value≤60HU (n=150 and mixed plaque group (CT value 60-130HU (n=183 by coronary CT angiography (CTA, and 100 healthy subjects who received physical examination in our hospital during the same period were selected as control group. Differences in platelet function and serum biochemical indexes were compared among four groups of patients, and the judgment value of atheromatous plaque CT value from CTA for the severity of coronary heart disease was analyzed. Results: Platelet function parameters MPV, TEG-MA, P-selectin, PDGF-BB and vWF levels in peripheral blood of soft plaque group were higher than those of the other three groups; inflammatory factors CRP, IL-6, IL-12, IL-18 and IL-23 content in serum were higher than those of the other three groups; chemokines MCP-1, CXCL16, Fractalkine and RANTES content in serum were higher than those of the other three groups; adipocytokines Leptin and RBP4 content in serum were higher than those of the other three groups while SFRP5 content was lower than those of the other three groups. Atheromatous plaque CT value in patients with coronary heart disease was directly correlated with platelet function and the content of serum biochemical indexes. Conclusions: Coronary CTA can accurately assess coronary atheromatous plaque features, and can also be a reliable noninvasive method to judge coronary heart disease severity, treatment prognosis and so on.

  3. A zwitterionic gel electrolyte for efficient solid-state supercapacitors

    Science.gov (United States)

    Peng, Xu; Liu, Huili; Yin, Qin; Wu, Junchi; Chen, Pengzuo; Zhang, Guangzhao; Liu, Guangming; Wu, Changzheng; Xie, Yi

    2016-01-01

    Gel electrolytes have attracted increasing attention for solid-state supercapacitors. An ideal gel electrolyte usually requires a combination of advantages of high ion migration rate, reasonable mechanical strength and robust water retention ability at the solid state for ensuring excellent work durability. Here we report a zwitterionic gel electrolyte that successfully brings the synergic advantages of robust water retention ability and ion migration channels, manifesting in superior electrochemical performance. When applying the zwitterionic gel electrolyte, our graphene-based solid-state supercapacitor reaches a volume capacitance of 300.8 F cm−3 at 0.8 A cm−3 with a rate capacity of only 14.9% capacitance loss as the current density increases from 0.8 to 20 A cm−3, representing the best value among the previously reported graphene-based solid-state supercapacitors, to the best of our knowledge. We anticipate that zwitterionic gel electrolyte may be developed as a gel electrolyte in solid-state supercapacitors. PMID:27225484

  4. Study on the diagnostic values of changes of serum endometrium antibody (EMAb) and CA125 (CA125) levels in patients with endometriosis

    International Nuclear Information System (INIS)

    Yang Jingxiu; Shi Shaohong; Wang Yuping

    2005-01-01

    Objective: To explore the diagnostic values of changes of serum EMAb and CA125 levels in patients with endometriosis. Methods: Serum EMAb levels were measured with ELISA and CA125 levels with RIA in 54 patients with endometriosis and 35 controls. Results: Positive rate of serum EMAb was significantly higher in the patients with endometriosis than those in controls (P≤0.01). Serum CA125 levels were also significantly higher than those in controls (P<0.01). Conclusion: Combined detection of serum EMAb positive rate and CA125 levels was of diagnostic value in patients with endometriosis. (authors)

  5. Clinical value of detecting the serum level of TRAb of GD progeny in gestational period

    International Nuclear Information System (INIS)

    Zou Jinhai; Li Xue; Zhang Qingfeng; Wang Yansheng; Wang Jianchun

    2011-01-01

    Objective: To investigate the relationship between thyroid function and serum TRAb level of neonates borned by puerperal who have Graves disease. Methods: To detect the serum levels of FT 3 , FT 4 , sTSH (with RIA) and TRAb (with ECLIA) in 126 neonates borned by puerperal who had Graves disease and 40 neonates borned by healthy puerperal. Results: The incidence of thyroid dysfunction was 25.4% (32/126) in 126 neonates borned by puerperal who had Graves' disease. Among them, the increase of serum TRAb occupied 1.59%(2/126), the incidence of hypothyroidism made up 23.81% (30/126), the ratio of neonates who had normal serum TRAb was 98.41% (124/126), the ratio of neonates who had normal thyroid function Ab was 74.60% (94/126). The serum levels of FT 3 , FT 4 , sTSH and TRAb in 40 neonates borned by healthy puerperal were normal. Conclusion: It has important clinical value by detecting the serum TRAb level of neonates borned by puerperal who have Graves' disease to diagnose diseases of thyroid gland in neonates, especially only one Graves' disease. (authors)

  6. Prognostic value of serum thioredoxin levels in ischemic stroke.

    Science.gov (United States)

    Yu, Tieer; Zhang, Wanli; Lin, Yuanshao; Li, Qian; Xue, Jie; Cai, Zhengyi; Cheng, Yifan; Shao, Bei

    2017-11-01

    Thioredoxin (Trx) is one of significant antioxidative molecules to diminish oxidative stress. Current evidence suggests that Trx is a potent antioxidant with cytoprotective functions. The aim of our study was to investigate specifically the association between serum Trx levels and acute ischemic stroke (AIS) patients. 198 AIS patients and 75 controls were enrolled to the study. Serum Trx levels were measured using an enzyme-linked immunosorbent assay (ELISA). Stroke severity was assessed with the National Institutes of Health Stroke Scale (NIHSS) score on admission. Clinical endpoint was functional outcome measured by Barthel Index (BI) 3 months after admission. Multivariate binary logistic regression analyses were performed to identify predictors. We found that serum Trx levels were significantly increased in patients as compared to controls. Serum Trx was an independent biomarker to predict ischemic stroke (OR, 1.264; 95% CI, 1.04-1.537; P = 0.019). In addition, there was a negative correlation between NIHSS score at admission and serum Trx levels in cardioembolic stroke patients (r = -0.422; P = 0.013). Furthermore, higher serum Trx levels in AIS patients were associated with favorable functional outcome. Serum Trx was an independent predictor for the functional outcome (OR, 0.862; 95% CI, 0.75-0.991; P = 0.037). Serum Trx might be as a biomarker of cardioembolic stroke severity. Increased serum Trx levels could be a useful tool to predict good prognosis in patients with AIS.

  7. The value of serum procalcitonin content for assessing the inflammation and organ injury in neonatal septicemia

    Directory of Open Access Journals (Sweden)

    Shao-Fang Li1

    2017-04-01

    Full Text Available Objective: To study the value of serum procalcitonin content for assessing the inflammation and organ injury in neonatal septicemia. Methods: 48 children with neonatal septicemia who were treated in our hospital between April 2014 and May 2016 were selected as the observation group, 50 healthy newborns who were delivered in our hospital during the same period were selected as the normal control group, and the observation group were further divided into high PCT group and low PCT group (n=24 according to the median of serum PCT content. Enzyme-linked immunosorbent assay (ELISA was used to detect the serum contents of inflammatory mediators, and color Doppler diasonograph was used to measure heart injury index levels. Results: Peripheral blood PCT content of observation group was significantly higher than that of control group (P<0.05; serum inflammatory mediators IL-1β, IL-6, IL-8 and TNF-α contents of high PCT group and low PCT group were significantly higher than those of normal control group, and as the PCT content increased, serum inflammatory mediators interleukin-1β (IL-1β, interleukin-6 (IL-6, interleukin-8 (IL-8 and tumor necrosis factor-α (TNF-α contents increased (P<0.05; routine ultrasound parameters cardiac output (CO and left ventricular ejection fraction (LVEF levels as well as the absolute value of twodimensional speckle tracking imaging parameters left ventricular global longitudinal strain rate (GLSr and left ventricular global circumferential strain rate (GCSr of high PCT group and low PCT group were lower than those of normal control group while serum myocardial injury indexes cardiac troponin I (cTnI, heart-type fatty acid-binding protein (H-FABP and α-hydroxybutyric dehydrogenase (HBDH contents were higher than those of normal control group, and as the PCT content increased, CO and LVEF levels as well as the absolute value of GLSr and GCSr decreased while the indexes cTnI, H-FABP and HBDH contents increased (P<0

  8. The Prognostic Value of C-Reactive Protein Serum Levels in Patients with Uterine Leiomyosarcoma.

    Directory of Open Access Journals (Sweden)

    Richard Schwameis

    Full Text Available C-reactive protein (CRP has previously been shown to serve as a prognostic parameter in women with gynecologic malignancies. Due to the lack of valid prognostic markers for uterine leiomyosarcoma (ULMS this study set out to investigate the value of pre-treatment CRP serum levels as prognostic parameter.Data of women with ULMS were extracted from databases of three Austrian centres for gynaecologic oncology. Pre-treatment CRP serum levels were measured and correlated with clinico-pathological parameters. Univariate and multivariable survival analyses were performed.In total, 53 patients with ULMS were included into the analysis. Mean (SD CRP serum level was 3.46 mg/dL (3.96. Solely, an association between pre-treatment CRP serum levels and tumor size (p = 0.04 but no other clinic-pathologic parameter such as tumor stage (p = 0.16, or histological grade (p = 0.07, was observed. Univariate and multivariable survival analyses revealed that CRP serum levels (HR 2.7 [1.1-7.2], p = 0.037 and tumor stage (HR 6.1 [1.9-19.5], p = 0.002 were the only independent prognostic factors for overall survival (OS in patients with ULMS. Patients with high pre-treatment CRP serum levels showed impaired OS compared to women with low levels (5-year-OS rates: 22.6% and 52.3%, p = 0.007.High pre-treatment CRP serum levels were independently associated with impaired prognosis in women with ULMS and might serve as a prognostic parameter in these patients.

  9. Water, electrolytes, vitamins and trace elements – Guidelines on Parenteral Nutrition, Chapter 7

    Directory of Open Access Journals (Sweden)

    Working group for developing the guidelines for parenteral nutrition of The German Association for Nutritional Medicine

    2009-11-01

    Full Text Available A close cooperation between medical teams is necessary when calculating the fluid intake of parenterally fed patients. Fluids supplied parenterally, orally and enterally, other infusions, and additional fluid losses (e.g. diarrhea must be considered. Targeted diagnostic monitoring (volume status is required in patients with disturbed water or electrolyte balance. Fluid requirements of adults with normal hydration status is approximately 30–40 ml/kg body weight/d, but fluid needs usually increase during fever. Serum electrolyte concentrations should be determined prior to PN, and patients with normal fluid and electrolyte balance should receive intakes follwing standard recommendations with PN. Additional requirements should usually be administered via separate infusion pumps. Concentrated potassium (1 mval/ml or 20% NaCl solutions should be infused via a central venous catheter. Electrolyte intake should be adjusted according to the results of regular laboratory analyses. Individual determination of electrolyte intake is required when electrolyte balance is initially altered (e.g. due to chronic diarrhea, recurring vomiting, renal insufficiency etc.. Vitamins and trace elements should be generally substituted in PN, unless there are contraindications. The supplementation of vitamins and trace elements is obligatory after a PN of >1 week. A standard dosage of vitamins and trace elements based on current dietary reference intakes for oral feeding is generally recommended unless certain clinical situations require other intakes.

  10. The study on clinical value of the detection about serum and Unconjugated Bilirubin in diagnosis of neonatal jaundice.

    Science.gov (United States)

    Wang, Guangzhou; Wang, Jiefei; Huang, Nannan; Yu, Fengqin

    2016-01-01

    In this paper, the clinical value of the detection about serum and unconjugated bilirubin (UCB) in neonatal jaundice was studied to found an effective and rapid method for diagnose of neonatal jaundice. ALB (Serum Albumin), total serum bilirubin (TSB) and UCB were detected by ELISA method among the 100 cases with neonatal jaundice selected for the study. The values of ALB, UCB and TSB in moderate jaundice patients were (42.83±3.87) g/L, (287.35±44.38) μm/L, (304.16±43.40) μm/L, respectively; as for the severe jaundice patients, the values were (38.41±4.82) g/L, (354.38±48.75) μm/L, (375.20±47.51) μm/L. The results showed significant differences with the pjaundice patients. The level of ALB, UCB, TSB in hemolytic jaundice, obstructive jaundice and jaundice caused by other infections also had significant differences, and the difference was statistically significant (pjaundice.

  11. How the reference values for serum parathyroid hormone concentration are (or should be) established?

    Science.gov (United States)

    Souberbielle, J-C; Brazier, F; Piketty, M-L; Cormier, C; Minisola, S; Cavalier, E

    2017-03-01

    Well-validated reference values are necessary for a correct interpretation of a serum PTH concentration. Establishing PTH reference values needs recruiting a large reference population. Exclusion criteria for this population can be defined as any situation possibly inducing an increase or a decrease in PTH concentration. As recommended in the recent guidelines on the diagnosis and management of asymptomatic primary hyperparathyroidism, PTH reference values should be established in vitamin D-replete subjects with a normal renal function with possible stratification according to various factors such as age, gender, menopausal status, body mass index, and race. A consensus about analytical/pre-analytical aspects of PTH measurement is also needed with special emphasis on the nature of the sample (plasma or serum), the time and the fasting/non-fasting status of the blood sample. Our opinion is that blood sample for PTH measurement should be obtained in the morning after an overnight fast. Furthermore, despite longer stability of the PTH molecule in EDTA plasma, we prefer serum as it allows to measure calcium, a prerequisite for a correct interpretation of a PTH concentration, on the same sample. Once a consensus is reached, we believe an important international multicentre work should be performed to recruit a very extensive reference population of apparently healthy vitamin D-replete subjects with a normal renal function in order to establish the PTH normative data. Due to the huge inter-method variability in PTH measurement, a sufficient quantity of blood sample should be obtained to allow measurement with as many PTH kits as possible.

  12. Diagnostic value of serum and ascitic fluid AFP, CEA and CA125 contents determination for differentiation of benign from malignant ascites

    International Nuclear Information System (INIS)

    Zhu Huanxing; Yang Yongqing

    2003-01-01

    Objective: To investigate the diagnostic value of determination of serum and ascitic fluid AFP, CEA and CA125 contents for differentiating benign from malignant ascites. Methods: Serum and ascitic fluid contents of the three tumor markers were measured with RIA in 86 patients with ascites due to various causes. Results: The serum and ascitic fluid AFP, CEA and CA125 levels in patients with malignant ascites were very significantly higher than those in patients with benign ascites (p<0.01). For differentiation of benign (mainly T.B and liver cirrhosis) from malignant ascites, CA125≥500 IU/ml and AFP≥300 ng/ml could be taken as the critical value with high specificity and accuracy. Conclusion: Determinations of the three tumor markers levels in serum and ascitic fluid were of high value for differential diagnosis of the etiology of ascites

  13. The value of serum mean platelet volume in ischaemic stroke patient

    International Nuclear Information System (INIS)

    Tamer, F.; Fevzi, Y.; Deniz, A.E.; Cemil, K.; Cihat, Y.; Muhittin, Y.; Serkan, Y.M.; Ali, C.M.; Faith, B.

    2013-01-01

    Objective: To investigate the value of serum Mean Platelet Volume in acute ischaemic stroke patients. Method: The retrospective case-control study was conducted at Ankara Numune Training and Research Hospital in Turkey and comprised record of patients of acute ischaemic stroke admitted to the Emergency Department between June 2010 and January 2012. The two groups were statistically compared using SPSS 18.0. Result: Overall, there were 482 stroke patients (Group 1) and 315 subjects as controls (Group 2). The median value in Group 1 was 9.0 (2.1) (fL), while in Group 2 it was 8.80 (2.4) (fL). The difference was statistically significant (Z=-2.80; p<0.05). Conclusion: Mean Platelet Volume increased in the stroke patients. (author)

  14. Effects of Gentamicin on Urinary Electrolyte Excretion in Admitted Neonate

    Directory of Open Access Journals (Sweden)

    B. Falakolaflaki

    2008-01-01

    Full Text Available Introduction & Objective: Gentamicin is an aminoglycoside antibiotic widely used during the neonatal period. It is associated with nephrotoxic effects in neonates, including glomerular impairment and renal tubular dysfunction. Electrolyte balance is very important, especially in the sick premature neonate receiving aminoglycosides. The purpose of this study was early diagnosis of gentamicin nephrotoxicity. Materials & Methods: This quasi-experimental study was performed on 23 neonates (11 full – term and 12 preterm with suspected sepsis who were admitted and treated with gentamicin. Blood and urine samples were collected before infusion and on the 3rd day of treatment. Serum and urine concentration of Na, K, creatinine (Cr and urine concentration of Ca were measured. Then fractional excretion of Na and K were estimated. Ca excretion was estimated as the UCa/UCr ratio. Then the collected data were analyzed using SPSS package.Results: In all neonates, increase in fractional excretion of Na and UCa/UCr, in the 3rd day of treatment were observed as compared to those of before infusion (P=0.01 and P=0.02 respectively. Serum creatinine levels decreased in all patients. Serum level of electrolytes during therapy was normal.Conclusion: The results of this study clearly demonstrate an effect of gentamicin infusion on renal sodium and calcium excretion. These results may be of clinical importance especially for sick preterm neonates receiving treatment with gentamicin. These babies are usually salt-losers and are also more susceptible to early onset hypocalcemia. Gentamicin can aggravate these complications.

  15. Seasonal variation of serum biochemical values of Amazonian snakes (Boa constrictor constrictor kept in captivity

    Directory of Open Access Journals (Sweden)

    Dennis José da Silva Lima

    2012-11-01

    Full Text Available In northern Brazil, the seasons are not well defined compared to the South and Southeast regions, due to a hot and humid equatorial climate with a rainy season, known as the Amazonian winter, and a period with less rain, known as the Amazonian summer. The goal of this study was to evaluate the biochemical variation of serum from the Amazon Boa constrictor by correlating the values with the seasons of the region. A biochemical analysis of the serum was performed (AST, ALT, LDH, ALP, calcium, uric acid, phosphorus, total protein, albumin and globulin using 31 individuals of Boa constrictor constrictor, which were kept in captivity. It was observed that eight of the ten parameters were higher in the winter compared to the summer (total protein, albumin, globulin, ALT, AST, ALP, LDH and calcium. The ALT, AST and calcium values had statistically significant differences for the summer and winter, while the other parameters appear to be influenced by seasonality. This was the first study of snakes kept in captivity that analyzed the serum chemistry profile of Boa constrictor constrictor from the state of Pará, Brazil.

  16. Serum chemistry reference values for the common genet (Genetta genetta): variations associated with Leishmania infantum infection.

    Science.gov (United States)

    Millán, Javier; Chirife, Andrea D; Altet, Laura

    2015-03-01

    The role of wildlife in the epidemiology of leishmaniosis in under debate, and determining whether infection with Leishmania infantum causes illness in wild carnivores is important to determine its potential role as a reservoir. To provide for the first time serum biochemistry reference values for the common genet (Genetta genetta), and to determine variations associated with L. infantum infection. Twenty-five serum biochemistry parameters were determined in 22 wild-caught genets. Blood samples were analyzed for L. infantum DNA by means of real-time polymerase chain reaction (PCR). Two female genets were positive for L. infantum DNA but did not show any external clinical sign upon physical examination. Among other variations in the biochemistry values of these genets, one presented a higher concentration of gamma-globulins and cholesterol, whereas the other genet presented increased creatinine, bilirubin, and chloride levels when compared to uninfected females. Sex-related differences in some parameters were also reported. Infection with L. infantum may sometimes be accompanied by abnormal serum biochemistry in wild carnivores. Clinical disease may occur in L. infantum-infected wild carnivores. This has implications in the epidemiology of leishmaniosis. In addition, the data provided here would also be useful as reference values for researchers or rehabilitators working with the common genet.

  17. Investigations of the Electrochemical Stability of Aqueous Electrolytes for Lithium Battery Applications

    KAUST Repository

    Wessells, Colin; Ruffο, Riccardo; Huggins, Robert A.; Cui, Yi

    2010-01-01

    The electrolytic stability windows of several aqueous electrolytes were investigated by a constant current method. The electrode potential range depended upon the value of the imposed current. The magnitude of this behavior varied with the salt

  18. Nanoporous polymer electrolyte

    Science.gov (United States)

    Elliott, Brian [Wheat Ridge, CO; Nguyen, Vinh [Wheat Ridge, CO

    2012-04-24

    A nanoporous polymer electrolyte and methods for making the polymer electrolyte are disclosed. The polymer electrolyte comprises a crosslinked self-assembly of a polymerizable salt surfactant, wherein the crosslinked self-assembly includes nanopores and wherein the crosslinked self-assembly has a conductivity of at least 1.0.times.10.sup.-6 S/cm at 25.degree. C. The method of making a polymer electrolyte comprises providing a polymerizable salt surfactant. The method further comprises crosslinking the polymerizable salt surfactant to form a nanoporous polymer electrolyte.

  19. Serum butanol extractable iodine values for adolescents exposed in utero - Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Burrow, G N; Hamilton, H B; Man, E B

    1961-10-18

    Serum BEI determinations were performed on 249 fifteen year old exposed and nonexposed apparently normal children all of whom were in utero at the time of the atomic bombing in Nagasaki, Japan. The girls were more mature in growth and development than the boys; the boys were probably near the peak stress of adolescent development. No statistically significant difference of BEI values was found between exposed and control groups. The trimester of gestation of the children at the time of exposure appeared to have no conclusive effect on the BEI value, but the number of subjects from each trimester was too small for satisfactory statistical analysis. Eleven females with goiter were analyzed separately. There was a slight preponderance of goiter in the exposed group, but the difference was not significant. The mean BEI value for the males was significantly lower than that for the females. The mean BEI values for Japanese adolescents are higher than for adolescents in the Middle Atlantic and New England states in the United States. 31 references, 2 tables.

  20. Electrolytic decontamination of stainless steel using a basic electrolyte

    International Nuclear Information System (INIS)

    Childs, E.L.; Long, J.L.

    1981-01-01

    An electrolytic plutonium decontamination process or stainless steel was developed for use as the final step in a proposed radioactive waste handling and decontamination facility to be construced at the Rockwell International Rocky Flats plutonium handling facility. This paper discusses test plan, which was executed to compare the basic electrolyte with phosphoric acid and nitric acid electrolytes. 1 ref

  1. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... into 3 groups, according to whether their cell-associated HIV DNA load was or = 2,500 DNA copies/10(6) peripheral blood mononuclear cells. Clinical progression rates differed significantly between the groups (p value independent...... of serum HIV RNA (p value. Patients heterozygous for the CCR5 delta 32 allele had significantly lower HIV DNA loads than those homozygous for the normal allele (p

  2. Consequences of Androctonus mauretanicus and Buthus occitanus scorpion venoms on electrolyte levels in rabbits

    Directory of Open Access Journals (Sweden)

    Khadija Daoudi

    2017-01-01

    Full Text Available Androctonus mauretanicus (A. mauretanicus and Buthus occitanus (B. occitanus scorpions, which belong to the Buthidae family, are the most venomous scorpions in Morocco. For the first time, we investigated the effects of such scorpion venoms on serum electrolytes in subcutaneously injected rabbits. For this purpose, 3 groups of 6 albinos adult male rabbits (New Zealand were used in this experiment. Two of the groups were given a single subcutaneous injection of either crude Am venom (5 μg/kg or Bo venom (8 μg/kg whereas the third group (control group only received physiological saline solution (NaCl 0.9%. The blood samples were collected from injected rabbits via the marginal vein at time intervals of 30 min, 1 h, 2 h, 4 h, 6 h and 24 h after venom injection. The concentrations of electrolytes in the serum samples were measured. Our study indicates that scorpion envenomation in vivo, rabbit animal model, caused severe and persistent hypomagnesaemia and hypochloremia, which are accompanied of hypernatremia, hyperkalemia and hypercalcaemia. The intensity of electrolytes imbalance was clearly superior in the case of A. mauretanicus scorpion venom (although a lower quantity of venom was injected. This is coherent with the experimental data which indicate that A. mauretanicus venom is more toxic than B. occitanus venom.

  3. In situ formation of low friction ceramic coatings on carbon steel by plasma electrolytic oxidation in two types of electrolytes

    International Nuclear Information System (INIS)

    Wang Yunlong; Jiang Zhaohua

    2009-01-01

    In situ formation of ceramic coatings on Q235 carbon steel was achieved by plasma electrolytic oxidation (PEO) in carbonate electrolyte and silicate electrolyte, respectively. The surface and cross-section morphology, phase and elemental composition of PEO coatings were examined by means of scanning electron microscopy (SEM), X-ray diffraction (XRD) and energy-dispersive X-ray spectroscopy (EDS). The bond strength of the coating was determined using a direct pull-off test. The hardness as well as tribological properties of the ceramic coating was primarily studied. The results indicated that the coating obtained in carbonate electrolyte was Fe 3 O 4 , while the coating achieved from silicate electrolyte was proved to be amorphous. Both kinds of coatings showed coarse and porous surface. The Fe 3 O 4 coatings obtained in carbonate electrolyte showed a high bonding strength to the substrate up to 20 ± 2 MPa and the value was 15 ± 2 MPa for the amorphous coatings obtained in carbonate electrolyte. The micro hardness of the amorphous coating and the Fe 3 O 4 coating was 1001 Hv and 1413 Hv, respectively, which was more than two and three times as that of the Q235 alloy substrate (415 Hv). The friction coefficient exhibited by amorphous coating and Fe 3 O 4 coating was 0.13 and 0.11, respectively, both lower than the uncoated Q235 substrate which ranged from 0.17 to 0.35.

  4. Highly Quantitative Electrochemical Characterization of Non-Aqueous Electrolytes & Solid Electrolyte Interphases

    Energy Technology Data Exchange (ETDEWEB)

    Sergiy V. Sazhin; Kevin L. Gering; Mason K. Harrup; Harry W. Rollins

    2012-10-01

    The methods to measure solid electrolyte interphase (SEI) electrochemical properties and SEI formation capability of non-aqueous electrolyte solutions are not adequately addressed in the literature. And yet, there is a strong demand in new electrolyte generations that promote stabilized SEIs and have an influence to resolve safety, calendar life and other limitations of Li-ion batteries. To fill this gap, in situ electrochemical approach with new descriptive criteria for highly quantitative characterization of SEI and electrolytes is proposed. These criteria are: SEI formation capacity, SEI corrosion rate, SEI maintenance rate, and SEI kinetic stability. These criteria are associated with battery parameters like irreversible capacity, self-discharge, shelf-life, power, etc. Therefore, they are especially useful for electrolyte development and standard fast screening, allowing a skillful approach to narrow down the search for the best electrolyte. The characterization protocol also allows retrieving information on interfacial resistance for SEI layers and the electrochemical window of electrolytes, the other important metrics of characterization. The method validation was done on electrolyte blends containing phosphazenes, developed at Idaho National Laboratory, as 1.2M LiPF6 [80 % EC-MEC (2:8) (v/v) + 20% Phosphazene variety] (v/v), which were targeted for safer electrolyte variations.

  5. The Serum Anion Gap in the Evaluation of Acid-Base Disorders: What Are Its Limitations and Can Its Effectiveness Be Improved?

    OpenAIRE

    Kraut, Jeffrey A.; Nagami, Glenn T.

    2013-01-01

    The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8–10 mEq/L), an increase in anion concentrat...

  6. Nanoporous Hybrid Electrolytes for High-Energy Batteries Based on Reactive Metal Anodes

    KAUST Repository

    Tu, Zhengyuan; Zachman, Michael J.; Choudhury, Snehashis; Wei, Shuya; Ma, Lin; Yang, Yuan; Kourkoutis, Lena F.; Archer, Lynden A.

    2017-01-01

    electrolytes created by infusing conventional liquid electrolytes into nanoporous membranes provide exceptional ability to stabilize Li. Electrochemical cells based on γ-Al2O3 ceramics with pore diameters below a cut-off value above 200 nm exhibit long

  7. Electrochemical supercapacitor studies of porous MnO{sub 2} nanoparticles in neutral electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Srither, S.R.; Karthik, A.; Arunmetha, S. [Centre for Nano Science and Technology, K. S. Rangasamy College of Technology, Tiruchengode 637 215, Tamil Nadu (India); Murugesan, D. [Department of Nanoscience and Technology, Bharathiar University, Coimbatore 641 046, Tamil Nadu (India); Rajendran, V., E-mail: veerajendran@gmail.com [Centre for Nano Science and Technology, K. S. Rangasamy College of Technology, Tiruchengode 637 215, Tamil Nadu (India)

    2016-11-01

    In this study, porous MnO{sub 2} nanoparticles (sample A and sample B) with higher active surface area were synthesized using sonochemical and soft template methods. To determine the crystalline phase, the samples were characterized to study their microstructure, chemical composition, and physical properties. X-ray diffraction results showed that both the samples were amorphous. Microstructure study confirmed that the sample A is spherical, existing with rod-shaped morphology whereas sample B shows flake-like morphology. The Brunauer–Emmett–Teller results showed the value obtained for sample B to be 1559 m{sup 2} g{sup −1}, which is effectively high when compared to that of sample A. The electrochemical capacitor behavior of the prepared nanoparticles was investigated in 0.1 M Li{sub 2}SO{sub 4} and Na{sub 2}SO{sub 4} electrolytes. The cyclic voltammogram result showed that both the sample electrodes behave as an ideal capacitor in both electrolytes. The charge–discharge test result indicated that the highest specific capacitance value of 280 F g{sup −1} was obtained for sample B electrode in Na{sub 2}SO{sub 4} electrolyte with good capacity retention of 92.31% after 500 cycles. The electrochemical impedance spectroscopy measurements confirm that sample B electrode has a lower R{sub ct} value in Na{sub 2}SO{sub 4} electrolyte when compared to that in Li{sub 2}SO{sub 4} electrolyte. - Highlights: • Porous MnO{sub 2} nanoparticles are synthesized using two different methods. • Spherical with rod-shaped and flake-like morphology is observed for sample A and B. • Specific capacitance of 280 F g{sup −1} is obtained for sample B in Na{sub 2}SO{sub 4} electrolyte. • EIS confirms that sample B has a lower R{sub ct} value in Na{sub 2}SO{sub 4} electrolyte.

  8. SERUM SODIUM CHANGES IN NEONATES RECEIVING PHOTOTHERAPY FOR NEONATAL HYPERBILIRUBINEMIA

    Directory of Open Access Journals (Sweden)

    Sunil Kumar

    2015-07-01

    Full Text Available BACKGROUND : Neonates receiving phototherapy have side effects like hypocalcemia and electrolyte changes. Our study is hereby intended to study the serum sodium changes due to phototherapy. AIMS : To evaluate the serum sodium changes in neonates receiving phototherapy f or neonatal hyperbilirubinemia. SETTINGS AND DESIGN : A prospective hospital based comparative study conducted on neonates admitted in the Neonatal Intensive Care Unit receiving phototherapy. METHODS AND MATERIAL : A predesigned proforma has aided the enroll ment of 252 newborns into the study. Serum bilirubin and serum sodium were determined before and after termination of phototherapy. The first samples were considered as controls. A comparative study was made between before and after phototherapy groups to determine the incidence of serum sodium imbalances. STATISTICAL ANALYSIS USED : Proportions will be compared using chi - square test. All data of various groups will be tabulated and statistically analyzed using suitable statistical tests (Student's t test. RESULTS : Male to Female ratio was 1.45 : 1. Incidence of low birth weight babies was 23% and preterm was 20.2%. Mean birth weight and gestational age was 2.84±0.51 kg and 38.44±1.98 wks respectively. Mean duration of phototherapy was 37.65±11.06 hrs. The incidence of hyponatremia post phototherapy found to be 6% which was more in low birth weight (LBW babies (17.2% , p48 hrs (p<0.001. Even the decline in mean serum sodium values after phototherapy found to be statistically significant. CONCLUSION : Our study shows that neonates u nder phototherapy are at higher risk of hyponatremia. This risk is greater in premature and LBW babies and hence this group of babies should be closely monitored for changes in serum sodium and should be managed accordingly.

  9. Diagnostic value of serum squamous cell carcinoma antigen for hepatocellular carcinoma: a systematic review and meta-analysis.

    Science.gov (United States)

    Yu, Jing; Wang, Zhao-Juan; Chen, Long-Hua; Dong, Wen-Zhu

    2017-02-01

    The aim of this study was to ascertain the diagnostic value of serum squamous cell carcinoma antigen (SCCA) and SCCA-IgM for hepatocellular carcinoma (HCC). After a comprehensive search of PubMed and Web of Science databases, we identified eligible studies on the diagnostic value serum SCCAs for HCC. The quality of the eligible studies was assessed using the revised Quality Assessment for Studies of Diagnostic Accuracy (QUADAS-2) tool. The overall diagnostic value of SCCAs for HCC was pooled using a bivariate model. Twelve studies were included in this systematic review and meta-analysis. The pooled sensitivities for SCCA and SCCA-IgM were 0.61 (95% confidence interval [CI], 0.37-0.81) and 0.70 (95% CI, 0.55-0.82), respectively. The corresponding specificities were 0.80 (95% CI, 0.52-0.94) and 0.62 (95% CI, 0.51-0.72), respectively. The areas under summary receiver operating characteristic (sROC) curves for SCCA and SCCA-IgM were 0.76 (95% CI, 0.72-0.80) and 0.70 (95% CI, 0.66-0.74), respectively. Major design deficiencies of the included studies were two-gate design and partial verification bias. Therefore, we concluded that both serum SCCA and SCCA-IgM have a fair diagnostic value for HCC.

  10. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... of serum HIV RNA (p normal allele (p

  11. Serum total prostate-specific antigen values in men with symptomatic prostate enlargement in Nigeria: role in clinical decision-making.

    Science.gov (United States)

    Nnabugwu, Ikenna I; Ugwumba, Fred O; Enivwenae, Oghenekaro A; Udeh, Emeka I; Otene, Chris O; Nnabugwu, Chinwe A

    2015-01-01

    Prostatic enlargement is a common cause of bladder outlet obstruction in men in Nigeria. Malignant enlargements must be differentiated from benign enlargements for adequate treatment of each patient. High serum total prostate-specific antigen (tPSA) levels suggest malignancy, but some of the biopsies done due to a serum tPSA value >4 ng/mL would be negative for malignancy because of the low specificity of tPSA for prostate cancer. This study aims to compare the histologic findings of all prostate specimens obtained from core needle biopsy, open simple prostatectomy, and transurethral resection of the prostate with the respective serum tPSA values in an attempt to decipher the role of serum tPSA in the management of these patients. The case notes of patients attended to from April 2009 to March 2012 were analyzed. Essentially, the age of the patient, findings on digital rectal examination, abdominopelvic ultrasonography report on the prostate, serum tPSA, and histology reports from biopsy or prostatectomy specimens as indicated were extracted for analysis. The relationship between age, findings on digital rectal examination, serum tPSA, abdominopelvic ultrasonography report, and histology are compared. A statistically significant relationship existed between a malignant histology and age 65 years and older, suspicious findings on digital rectal examination, suspicious ultrasonography findings, and serum tPSA >10 ng/mL, but not tPSA >4 ng/mL. In Nigerian patients with symptomatic prostate enlargement, serum tPSA should be seen as a continuum with increasing risk of prostate malignancy.

  12. Population Reference Values for Serum Methylmalonic Acid Concentrations and Its Relationship with Age, Sex, Race-Ethnicity, Supplement Use, Kidney Function and Serum Vitamin B12 in the Post-Folic Acid Fortification Period

    Directory of Open Access Journals (Sweden)

    Vijay Ganji

    2018-01-01

    Full Text Available Serum methylmalonic acid (MMA is elevated in vitamin B-12 deficiency and in kidney dysfunction. Population reference values for serum MMA concentrations in post-folic acid fortification period are lacking. Aims of this study were to report the population reference values for serum MMA and to evaluate the relation between serum MMA and sex, age, race-ethnicity, kidney dysfunction and vitamin B-12. We used data from three National Health and Nutrition Examination Surveys, 1999–2000, 2001–2002 and 2003–2004 conducted after folic acid fortification commenced (n = 18,569. Geometric mean MMA was ≈22.3% higher in non-Hispanic white compared to non-Hispanic black (141.2 vs. 115.5 nmol/L and was ≈62.7% higher in >70 years old persons compared to 21–30 years old persons (196.9 vs. 121.0 nmol/L. Median serum MMA was ≈28.5% higher in the 1st the quartile of serum vitamin B-12 than in the 4th quartile of serum vitamin B-12 and was ≈35.8% higher in the 4th quartile of serum creatinine than in the 1st quartile of serum creatinine. Multivariate-adjusted serum MMA concentration was significantly associated with race-ethnicity (p < 0.001 and age (p < 0.001 but not with sex (p = 0.057. In this large US population based study, serum MMA concentrations presented here reflect the post-folic acid fortification scenario. Serum MMA concentrations begin to rise at the age of 18–20 years and continue to rise afterwards. Age-related increase in serum MMA concentration is likely to be due to a concomitant decline in kidney function and vitamin B-12 status.

  13. Comparison of the Efficacy of Serum Creatinine and Microalbuminuria in Early Diagnosis of Renal Injury in Asphyxiated Infants in Calabar, Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Sunny Oteikwu Ochigbo

    2017-06-01

    Full Text Available Background: Microalbuminuria and serum creatinine are the specific markers of acute renal injury. Perinatal asphyxia is responsible for 50% of all neonatal deaths and nonoliguric acute renal injuryis one of its complications. This study was undertaken to determine the efficacy of serum creatinine and microalbuminuria for early diagnosis of renal injury in severely asphyxiated neonates in Calabar, Nigeria.Methods: This prospective cross-sectional study was performed among severely asphyxiated newborns admitted into the neonatal wards of the University of Calabar Teaching Hospital (UCTH. Standard methods for the determination of blood urea and electrolyte were executed. Micral-test strips have been applied using urine dipstick and the result of the test was negative only for albumin. The developed colors have been compared five minutes after the first test.Results: Fifty full-term newborns were enrolled and their serum electrolytes, creatinine and the creatinine clearance were essentially normal. Six neonates demonstrated positive results in the microalbominuria assessment, while the rest were negative in this regard. The test has 0% sensitivity and 100% specificity, while the positive and negative predictive values were 0% and 88%, respectively.Conclusion: Microalbuminuria is not a useful marker for early diagnosis of acute renal failure in the newborns with severe prenatal asphyxia, but further studies are recommended.

  14. Trends of Serum Electrolyte Changes in Crush syndrome patients of Bam Earthquake; a Cross sectional Study

    Directory of Open Access Journals (Sweden)

    Saeed Safari

    2016-12-01

    Full Text Available Introduction: Electrolyte imbalances are very common among crushed earthquake victims but there is notenough data regarding their trend of changes. The present study was designed to evaluate the trend of changesin sodium, calcium, and phosphorus ions among crush syndrome patients. Methods: In this retrospectivecross-sectional study, using the database of Bam earthquake victims, which was developed by Iranian Society ofNephrology following Bam earthquake, Iran, 2003, the 10-day trend of sodium, calcium, and phosphorus ionschanges in > 15 years old crush syndrome patients was evaluated. Results: 118 patients with the mean age of25.6 § 6.9 yearswere studied (57.3 male. On the first day of admission, 52.5% (95% CI: 42.7 - 62.3 of the patientshad hyponatremia, which reached 43.9% (95% CI: 28.5 - 59.3 on day 10. 100.0% of patients were hypocalcemicon admission and serum calcium level did not change dramatically during the 10 days of hospitalization. Theprevalence of hyperphosphatemia on the first day was 90.5% (95% CI: 81.5 - 99.5 and on the 10th day of hospitalization66.7% (95% CI: 48.5 - 84.8 of the patients were still affected. Conclusion: The results of the presentstudy shows the 52.5%prevalence of hyponatremia, 100% hypocalcemia, and 90.5% hyperphosphatemia amongcrush syndrome patients of Bam earthquake victims on the first day of admission. Evaluation of 10-day trendshows a slow decreasing pattern of these imbalances as after 10 days, 43.9% still remain hyponatremic, 92.3%hypocalcemic, and 66.7% hypophosphatemic.

  15. Clinical value of serum bilirubin subfractionation by high-performance liquid chromatography and conventional methods in patients with primary biliary cirrhosis

    NARCIS (Netherlands)

    Jansen, P. L.; Peters, W. H.; Janssens, A. R.

    1986-01-01

    The clinical value of serum bilirubin subfractionation, using high-performance liquid chromatography (HPLC), was studied in 26 patients with primary biliary cirrhosis (PBC) from whom 59 serum samples were obtained. Total bilirubin (TB) levels were determined by alkaline methanolysis and HPLC

  16. Clinical value of blood lipid, serum β2-microglolulin and tumor necrosis factor-α level in patients with acute leukemia

    International Nuclear Information System (INIS)

    Shen Xiaohua; Huang Zhairong; Yang Yongqing

    2010-01-01

    Objective: To study on diagnosis value of blood lipid, serum β 2 -microglolulin (β 2 -MG) and tumor necrosis factor-α (TNF-α) in acute leukemia. Methods: The serum β 2 -MG and TNF-α (with radioimmunoassay) blood lipid (with biochemistry) levels were determined in 123 patients with acute leukemia as well as 36 controls, then conducted the correlative tests. Results: Serum β 2 -MG, TNF-α and triglyceride levels in 123 patients including 46 patients with acute monocytic leukemia, 32 patients with acute lymphocytic leukemia and 45 patients with acute nonlymphocytic leukemia were significantly higher than those in 36 controls (t=4.123-6.815, P 0.05); The serum cholesterol, high density lipoprotein-cholesterol, low density lipoprotein-cholesterol, apolipoprotein A levels in 123 patients with acute leukemia were significantly lower than those in 36 controls (t=2.110-2.574, P 0.05). Conclusion: The determination of blood lipid, serum β 2 -MG and TNF-α level might be useful for diagnosing acute leukemia and reflecting the prognostic value. (authors)

  17. Diagnostic value of tissue polypeptide specific antigen in serum for patients with pancreatic carcinoma

    International Nuclear Information System (INIS)

    Lu Yun; Liu Xingdang; Li Ding; Dei Shouzhen

    2009-01-01

    Objective: To compare the diagnostic value of tissue polypeptide specific antigen (TPS) in serum, with the carbohydrate antigens (CA) 19-9, CA50, CA125 and CA242 in pancreatic carcinoma. Methods: Serum TPS was measured with enzyme linked immunosorbent assay (ELISA). CA19-9 and CA125 were measured with chemiluminescent immunoassay. CAS0 and CA242 were measured with immunoradiometric assay in 33 patients with pancreatitis, 34 patients with pathologically proven pancreatic carcinoma, and 35 patients with non-pancreatic malignancies. Statistic analysis was carried out with SPSS 9.0 software. Results: Patients with pancreatic carcinoma had relatively higher levels of TPS [(386.5 ± 315. 1) U/L] and CA19-9 [(10 820.9 ± 389.7) kU/L] when compared with patients with pancreatitis [(86. 2 ± 28.1) U/L and (61.5 ± 24.7) kU/L, respectively; F = 936. 42, P < 0. 001 ; F = 2217. 09, P < 0. 001], with a sensitivity and a specificity of 70.6% (48/68) and 57.4% (39/68), respectively, for TPS, and 82.4% (28/34) and 77.9% (53/68), respectively, for CA19-9. Diagnostic performance was further improved when TPS was assayed in combination with CA19-9, CA50, CA125 and CA242. Conclusion: Serum TPS has an incremental value in complementing CA19-9 in the diagnosis of pancreatic carcinoma. (authors)

  18. Methods of pH determination in Calcareous soils of Oman: The effect of Electrolyte and soil solution ratio

    International Nuclear Information System (INIS)

    Al-Busaidi, A.; Cookson, P.

    2002-01-01

    Determination of pH assists in understanding many reactions that occur in soil. Soil pH values are highly sensitive to the procedure used for determination. In this study, pH was measured in different electrolytes [distilled water (pHw), 0.01MCaCl2 (pHCa), 1MKCl (pHk), and 0.01MBaCl2 (pHba)] with different soil: electrolyte ratios (i.e. 1:1, 1:2.5 and 1:5). The objective was to determine the effect of each electrolyte and dilution ratio on pH of saline and non-saline soils from Oman. It was found that ph values varied significantly between electrolytes and with different dilution ratios. Linear regression equations were generated between electrolytes, dilution ratios and were mostly significant. Soil pH values determined in different electrolytes were significantly interrelated. Water appeared as a highly suitable solvent for soil pH measurements because it is simple and values familiar to soil users. However, alkaline errors and electrode instabilities due to liquid junction and soluble salt effects, affected soil pH measurements, especially in water, and resulted in alkaline errors during pH measurements. Errors were minimized when pH was measured in electrolytes rather than in water. (author)

  19. Raman spectral and electrochemical studies of lithium/electrolyte interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Odziemkowski, M

    1922-01-01

    Cyclic voltammetry, corrosion potential-time transients and Normal Raman spectroscopy have been employed to characterize the lithium-lithium salt, organic solvent, interfacial region. An in-situ cutting technique was developed to expose lithium metal. In-situ optical and ex-situ scanning electron microscopy (SEM) have been used to examine the morphology of the lithium electrode surface during exposure at open circuit and after anodic polarization. The main reaction product detected by in-situ Raman spectroscopy in the system/lithium/LiAsF[sub 6], tetrahydrofuran (THF) electrolyte was polytetrahydrofuran (PTHF). The conditions for the polymerization reaction in the presence of lithium metal have been determined. Tetrahydrofuran (THF) decomposition reaction mechanisms are discussed. Decomposition reaction products have been determined as arsenic (II) oxide, As[sub 2]O[sub 3] (arsenolite) and arsenious oxyfluoride AsF[sub 2]-O-AsF[sub 2]. Potentiodynamic polarization measurements revealed a substantial shift of the corrosion potential towards positive values and only a moderate increase of anodic dissolution current for in-situ cut lithium metal. Corrosion potential-time merits have been measured. The following electrolytes have been investigated: LiAsF[sub 6], LiPF[sub 6], LiClO[sub 4], and Li(CF[sub 3]SO[sub 2])[sub 2]N in THF, 2Me-THF, and propylene carbonate (PC). The transients permit the ranking of the reactivity of the electrolytes. These measurements have shed light on understanding the stability of various stability and and solvents in contact with lithium. Compared to purified electrolytes, small amounts of water shift the corrosion potential towards even more positive values. Intensive anodic cycling of a Li electrode in unpurified LiAsF[sub 6]/THF electrolyte leads to the breakdown of a surface film/films. While at the open circuit potential (OCP), water in this same electrolyte leads to crack formation in the bulk lithium electrode.

  20. Investigation of alkaline-cyanide electrolytes of zinc plating

    International Nuclear Information System (INIS)

    Shaburova, V.P.; Kolotij, O.Yu.

    1993-01-01

    Current values in their maxima on anodic potential curves of Cd, Sn and Zn in galvanizing electrolytes with equilibrium concentrations of free cyanide and hydroxide ions were compared. Anode signal of Cd in the presence of Zn complexes intensifies due to their lability and, therefore, it reflects not only the presence of free cyanide, but zinc complex ions, as well, in the solution mentioned. This is one of the reasons for a high information content of the signal in case of multicomponent analysis of cyanide galvanizing electrolytes

  1. Determination of Theophylline Binding to Human Serum Proteins by Isotachophoresis

    NARCIS (Netherlands)

    Reijenga, J.C.; Gaijkema, A.P.M.; Mikkers, F.E.P.

    1984-01-01

    Free theophylline was isolated from human serum by ultrafiltration and analysed in a leading electrolyte of 7.5 mM morpholinoethanesulphoric acid with ammediol as a counter ion at pH 8.90 and -alanine as a terminator. The UV (280 nm) absorbance of the theophylline spike between serine and bicine as

  2. Enhanced performance of ultracapacitors using redox additive-based electrolytes

    Science.gov (United States)

    Jain, Dharmendra; Kanungo, Jitendra; Tripathi, S. K.

    2018-05-01

    Different concentrations of potassium iodide (KI) as redox additive had been added to 1 M sulfuric acid (H2SO4) electrolyte with an aim of enhancing the capacitance and energy density of ultracapacitors via redox reactions at the interfaces of electrode-electrolyte. Ultracapacitors were fabricated using chemically treated activated carbon as electrode with H2SO4 and H2SO4-KI as an electrolyte. The electrochemical performances of fabricated supercapacitors were investigated by impedance spectroscopy, cyclic voltammetry and charge-discharge techniques. The maximum capacitance ` C' was observed with redox additives-based electrolyte system comprising 1 M H2SO4-0.3 M KI (1072 F g- 1), which is very much higher than conventional 1 M H2SO4 (61.3 F g- 1) aqueous electrolyte-based ultracapacitors. It corresponds to an energy density of 20.49 Wh kg- 1 at 2.1 A g- 1 for redox additive-based electrolyte, which is six times higher as compared to that of pristine electrolyte (1 M H2SO4) having energy density of only 3.36 Wh kg- 1. The temperature dependence behavior of fabricated cell was also analyzed, which shows increasing pattern in its capacitance values in a temperature range of 5-70 °C. Under cyclic stability test, redox electrolyte-based system shows almost 100% capacitance retention up to 5000 cycles and even more. For comparison, ultracapacitors based on polymer gel electrolyte polyvinyl alcohol (PVA) (10 wt%)—{H2SO4 (1 M)-KI (0.3 M)} (90 wt%) have been fabricated and characterized with the same electrode materials.

  3. Clinical value of detection of serum β-Crosslaps, PINP and N-MID in postmenopausal women with osteoporosis

    International Nuclear Information System (INIS)

    Ou Mengmeng; Huang Jianrong

    2011-01-01

    To evaluate the clinical value of detection of concentration of β-Crosslaps, PINP and N-MID in postmenopausal women with osteoporosis, 116 postmenopausal women were detected by dual X-ray absorptionmetry and divided into NOP group (51 cases) and OP group (65 cases). The serum levels of three bone markers (β-Crosslaps, PINP and N-MID) were measured. The results showed that serum levels of β-Crosslaps, PINP and N-MID in OP group were significantly higher than that in NOP group (P<0.01). It was suggested that three bone markers level might be closely related with osteoporosis in postmenopausal women. The combined detection of bone markers and bone mineral density has important clinical value in the diagnosis of osteoporosis in postmenopausal women. (authors)

  4. Value of combined detection of serum AFP and GP73 in early diagnosis of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    GAO Haifeng

    2014-07-01

    Full Text Available ObjectiveTo investigate the value of combined detection of serum alpha-fetoprotein (AFP and Golgi protein-73 (GP73 in the diagnosis of hepatocellular carcinoma (HCC and to provide a basis for early diagnosis and differential diagnosis of HCC. MethodsA total of 408 patients hospitalized in Baoji Central Hospital from June 2012 to May 2013, as well as healthy persons who had normal test results in physical examination, were included in the study, and their specimens were collected. These patients were classified into HCC group (n=142, chronic hepatitis group (n=156, and liver cirrhosis group (n=110. Serum levels of AFP and GP73 in the three groups were measured by electrochemiluminescence immunoassay and double-antibody sandwich enzyme-linked immunosorbent assay, respectively. Comparison of test results between groups was made by analysis of variance, and comparison of rates was made by chi-square test. The sensitivity and specificity of the two indicators for the diagnosis of HCC were calculated using MedCalc statistical software. ResultsThe HCC group had significantly higher serum AFP and GP73 levels than the liver cirrhosis group and chronic hepatitis group (P<0.05; the liver cirrhosis group had significantly higher serum AFP and GP73 levels than the chronic hepatitis group (P<0.05. The sensitivity and specificity of the two indicators for the diagnosis of HCC were 95.8% and 98.6%, respectively, showing significant differences compared with those of each indicator alone (P<0.05. ConclusionCombined detection of serum AFP and GP73 has high diagnostic value and clinical significance for HCC, and they can be used as indicators for early diagnosis and differential diagnosis of HCC.

  5. A NOVEL GEL ELECTROLYTE FOR VALVE-REGULATED LEAD ACID BATTERY

    Directory of Open Access Journals (Sweden)

    Metin GENÇTEN

    2017-03-01

    Full Text Available A novel gel electrolyte system used in lead-acid batteries was investigated in this work. The gel systems were prepared by addition different amount of Al2O3, TiO2 and B2O3 into the gelled system consisting of 6 wt% fumed silica and 30 wt% sulfuric acid solution. The anodic peak currents and peak redox capacities of the gel electrolytes were characterized by cyclic voltammetric method. They decreased by the time B2O3 and Al2O3 were used as additives in fumed silica based gel electrolyte system. However, these values increased by the adding 3.0 wt% of TiO2. The solution and charge transfer resistances of the gel electrolytes were investigated by electrochemical impedance spectroscopy. While the solution resistances were lower in gel systems having different amount additives than pure fumed silica based gel, the charge transfer resistance was the lowest in gel electrolytes consisting fumed silica and fumed silica-TiO2. The battery performances were studied by obtaining discharge curves of prepared gel electrolytes. The performance of gelled systems were higher than that of non-gelled electrolyte at room temperature. The mixture of fumed silica-TiO2 was suggested an alternative gel formulation for gel VRLA batteries.

  6. [South American camelids in Switzerland. II. Reference values for blood parameters].

    Science.gov (United States)

    Hengrave Burri, I; Tschudi, P; Martig, J; Liesegang, A; Meylan, M

    2005-08-01

    In order to establish reference values for blood parameters of South American camelids in Switzerland, 273 blood samples were collected from 141 llamas and 132 alpacas. These animals were classified in three categories (young animals blood cell count, white blood cell count, electrolytes, metabolites and enzymes). Significant differences between llamas and alpacas were evident for 26 parameters. This study also showed that differences between young animals, females and males must be taken into consideration. A comparison of blood values with the results of fecal analysis for parasite eggs showed that an infestation with Dicrocoelium dendriticum was associated with elevated activity of two liver enzymes (GLDH and gamma-GT) in the serum. In contrast, no differences were found in the results of blood analyses between animals shedding eggs of gastrointestinal strongyles or not.

  7. Investigations of the Electrochemical Stability of Aqueous Electrolytes for Lithium Battery Applications

    KAUST Repository

    Wessells, Colin

    2010-01-01

    The electrolytic stability windows of several aqueous electrolytes were investigated by a constant current method. The electrode potential range depended upon the value of the imposed current. The magnitude of this behavior varied with the salt solution, its concentration, and pH of the electrolyte. At a leakage current density of 50 μA/cm2, a 5 M solution of LiNO3 had an electrolytic window of 2.3 V, spanning from -0.55 to 1.75 V with respect to the standard hydrogen electrode. These results demonstrate the feasibility of operating lithium batteries at voltages appreciably above the theoretical decomposition voltage of water. © 2010 The Electrochemical Society.

  8. Study on the clinical value of determination of serum adenosine deaminase (ADA) and HA, PIIIP levels for diagnosis of chronic hepatitis

    International Nuclear Information System (INIS)

    Ma Yun

    2007-01-01

    Objective: To explore the clinical value of determination of serum ADA and HA, PIIIP levels for diagnosis of chronic hepatitis. Methods: Serum ADA levels were determined with biochemistry and HA, PIIIP levels were detected with RIA in 36 patients with chronic hepatitis and 35 controls. Results: The levels of serum ADA, HA and PIIIP were significantly higher in the patients than those in controls (P<0.01). Serum ADA, HA, PIIIP levelers were mutually positively correlated (r=0.6117, 0.7134, P<0.01). Conclusion: Detection of serum ADA levels could reflect the liver reserve function and status of fibrosis. (authors)

  9. Serum potassium values in relation to the use of diuretics in patients with unstable angina pectoris

    NARCIS (Netherlands)

    van Gilst, W. H.; Tijssen, J. G.; van Es, G. A.; Lubsen, J.

    1988-01-01

    Transient hypokalaemia may occur in acutely ill patients and is associated with an increased incidence of life-threatening arrhythmias. Therefore, we performed a retrospective analysis of the serum potassium values of 538 patients with unstable angina included in the Holland Interuniversity

  10. Clinical diagnostic value of determination of plasma ET, Hcy and serum hs-CRP contents in patients with coronary heart diseases

    International Nuclear Information System (INIS)

    Chu Jingying; Zhu Xueming

    2008-01-01

    Objective: To study the clinical diagnostic value of determination of plasma ET, Hcy and serum hs-CRP contents in patients with coronary heart disease (CHD). Methods: Plasma ET, Hcy(with RIA) and serum hs-CRP (with immune turbidimetry) contents were determined in 38 patients with CHD and 35 controls. Results: Plasma ET, Hcy and serum hs-CRP concentration were significantly higher in CHD patients (than those in controls P<0.01). Plasma ET levels were significantly positively correlated with those of plasma Hcy and serum hs-CRP (r=0.6122, 0.5842, P<0.01). Conclusion: Detection of changes of plasma ET, Hcy and serum hs-CRP levels might be of prognostic importance in patients with CHD. (authors)

  11. Conductometry of electrolyte solutions

    Science.gov (United States)

    Safonova, Lyubov P.; Kolker, Arkadii M.

    1992-09-01

    A review is given of the theories of the electrical conductance of electrolyte solutions of different ionic strengths and concentrations, and of the models of ion association. An analysis is made of the methods for mathematical processing of experimental conductometric data. An account is provided of various theories describing the dependence of the limiting value of the ionic electrical conductance on the properties of the solute and solvent. The bibliography includes 115 references.

  12. Development of oxygen sensors using zirconia solid electrolyte for fuel rods

    International Nuclear Information System (INIS)

    Hiura, Nobuo; Endou, Yasuichi; Yamaura, Takayuki; Matui, Yoshinori; Niimi, Motoji; Hoshiya, Taiji; Kobiyama, Mamoru; Motohashi, Yoshinobu

    1999-01-01

    The oxygen potential in oxide fuel pellet is an important parameter to understand behavior of high burn up fuel and its integrity. Zirconia solid electrolyte which is durable under irradiation and high temperature is considered as candidate material for the oxygen potential. Combined use of solid electrolyte and Ni/NiO as a solid standard electrode will realize small size oxygen sensor which can be easily loaded in the fuel rod. Prototypes of the oxygen sensor made of these materials were irradiated with neutrons the Japan Materials Testing Reactor (JMTR), and characteristics of electromotive force (EMF) by sensors were examined under irradiation. For a prototype using zirconia solid electrolyte stabilized by Y 2 O 3 (YSZ), measured EMF under irradiation was nearly equivalent to the value under unirradiated condition, and very stable within a range of neutron fluence (E>1 MeV) up to 1.52 x 10 23 m -2 and for the time of 600 h. However, the measured EMFs were slightly smaller than the theoretical values. The reason for this decrease of the EMF was thought as due to insufficient adhesion forces between solid electrolyte and standard electrode. After modification of the sensor to increase adhesion force, EMF was measured again under irradiation. The results showed improvement of the characteristics of the sensor in which measured EMFs were almost equivalent to the theoretical values. (author)

  13. Dynamically observing the value of the changes of serum sex hormone levels of early pregnancy after drug-induced abortion

    International Nuclear Information System (INIS)

    Zhao Honggang; Dong Hua; Gu Yan; Zhang Zuncheng

    2009-01-01

    Objective: To observe the value of the changes of serum β-human chorionic gonadotropin (β-HCG), estradiol (E), progesterone (P) Levels of early pregnancy after drug-induced abortion dynamically. Methods: Assessing 55 women proved pregnant by urine or blood HCG retrospecticly, who had terminated their pregnancy by mifepristonr and misoprostol. Meanwhile the serum levels of β-HCG, E, P were monitored dynamically. Results: Among the 55 patients, the levels of β-HCG, E and P had significant decreased (t β-HCG =4.845, t E =7.655, t P =11.390, P E =9.089, P P =2.910, P<0.05). Conclusion: Detectint the serum hormone's levels after drug-induced abortion by chemiluminescent immunoassay, we can assess indirectly the value of administration of mifepristone and misoprostol, predict the prolonged vaginal bleeding after drug-induced abortion, and the outcome of the treatment, which determine wether need another curestage. (authors)

  14. Serum total prostate-specific antigen values in men with symptomatic prostate enlargement in Nigeria: role in clinical decision-making

    Directory of Open Access Journals (Sweden)

    Nnabugwu II

    2014-12-01

    Full Text Available Ikenna I Nnabugwu,1,2 Fred O Ugwumba,1 Oghenekaro A Enivwenae,2 Emeka I Udeh,1 Chris O Otene,2 Chinwe A Nnabugwu3 1Urology Unit, Department of Surgery, College of Medicine, University of Nigeria, Nsukka, 2Urology Unit, Department of Surgery, 3Department of Medical Laboratory Services, Federal Medical Centre, Asaba, Nigeria Background: Prostatic enlargement is a common cause of bladder outlet obstruction in men in Nigeria. Malignant enlargements must be differentiated from benign enlargements for adequate treatment of each patient. High serum total prostate-specific antigen (tPSA levels suggest malignancy, but some of the biopsies done due to a serum tPSA value >4 ng/mL would be negative for malignancy because of the low specificity of tPSA for prostate cancer. This study aims to compare the histologic findings of all prostate specimens obtained from core needle biopsy, open simple prostatectomy, and transurethral resection of the prostate with the respective serum tPSA values in an attempt to decipher the role of serum tPSA in the management of these patients.Methods: The case notes of patients attended to from April 2009 to March 2012 were analyzed. Essentially, the age of the patient, findings on digital rectal examination, abdominopelvic ultrasonography report on the prostate, serum tPSA, and histology reports from biopsy or prostatectomy specimens as indicated were extracted for analysis.Results: The relationship between age, findings on digital rectal examination, serum tPSA, abdominopelvic ultrasonography report, and histology are compared. A statistically significant relationship existed between a malignant histology and age 65 years and older, suspicious findings on digital rectal examination, suspicious ultrasonography findings, and serum tPSA >10 ng/mL, but not tPSA >4 ng/mL.Conclusion: In Nigerian patients with symptomatic prostate enlargement, serum tPSA should be seen as a continuum with increasing risk of prostate malignancy

  15. THE PREDICTIVE VALUE OF SERUM URIC ACID FOR THE OCCURRENCE, SEVERITY AND OUTCOMES OF PRE-ECLAMPSIA AMONG PARTURIENTS AT NNEWI, NIGERIA.

    Science.gov (United States)

    Osakwe, Chukwudi Richmond; Ikpeze, Okechukwu C; Ezebialu, Ifeanyi Uzoma; Osakwe, Joy Oluchi; Mbadugha, Norah Nwadiogo

    2015-01-01

    To determine the predictive value of serum uric acid for preeclampsia, its severity and pregnancy outcome. This is a cohort study that was performed on normal pregnant women attending antenatal clinic at Nnamdi Azikiwe University Teaching Hospital Nnewi Nigeria. Serum uric acid was determined in 200 women attending antenatal clinic between the gestational ages of 14 and 26 weeks. The women were followed up at 2 weekly intervals until 36 weeks and weekly thereafter until delivery. Women who developed pre-eclampsia or eclampsia were identified. Pregnancy outcomes were determined as well as fetal and placental weights. The data was analised with SPSS version 16.0. The chi square was used for test of significance. The positive and negative predictive values were determined. A total of 200 normal pregnant women were recruited for the study. Nine of them were lost to follow up. Subsequently, 10.5% of the women developed preeclampsia. The positive and negative predictive values of serum uric acid for preeclampsia were 78.9% and 97.1%, respectively. Serum uric acid was found to be a useful predictor of the occurrence of preeclampsia and its severity.

  16. Clinical diagnostic value of combined determination of serum tPSA, cPSA and IGF-I levels in patients with prostatic disorders

    International Nuclear Information System (INIS)

    Zhang Bashan; Zhang Zigang; Lai Fudi

    2008-01-01

    Objective: To investigate the diagnostic value of combined determination of serum total prostatic specific antigen (tPSA), complex prostatic specific antigen (cPSA) and IGF-I levels in patients with prostatic disorders. Methods: Serum tPSA, cPSA (with CLIA) and IGF-I (with IRMA) levels were determined in 41 patients with prostatic carcinoma, 60 patients with benign prosta- tic hypertrophy (BPH) and 55 controls. Results: The serum tPSA, cPSA and IGF-I levels in patients with prostatic cancer were significantly higher than those in patients with BPH and controls (P<0.01). Taking the cut-off values of 4ng/ml, 3.6ng/ml and 150 for tPSA, cPSA and IGF-I respectively, the combined determination of these three items would yield a sensitivity of 88.6%, specificity of 84.9%, positive predicative value of 83% and negative predicative value of 90.0% for diagnosis of prostatic cancer. Conclusion: Combined determination of tPSA, cPSA and IGF-I would yield better sensitive and accurate diagnostic rate in patients with prostatic cancer, especially in those with laboratory values within the 'grey zone'. (authors)

  17. Differential diagnosis of nongap metabolic acidosis: value of a systematic approach.

    Science.gov (United States)

    Kraut, Jeffrey A; Madias, Nicolaos E

    2012-04-01

    Nongap metabolic acidosis is a common form of both acute and chronic metabolic acidosis. Because derangements in renal acid-base regulation are a common cause of nongap metabolic acidosis, studies to evaluate renal acidification often serve as the mainstay of differential diagnosis. However, in many cases, information obtained from the history and physical examination, evaluation of the electrolyte pattern (to determine if a nongap acidosis alone or a combined nongap and high anion gap metabolic acidosis is present), and examination of the serum potassium concentration (to characterize the disorder as hyperkalemic or hypokalemic in nature) is sufficient to make a presumptive diagnosis without more sophisticated studies. If this information proves insufficient, indirect estimates or direct measurement of urinary NH(4)(+) concentration, measurement of urine pH, and assessment of urinary HCO(3)(-) excretion can help in establishing the diagnosis. This review summarizes current information concerning the pathophysiology of this electrolyte pattern and the value and limitations of all of the diagnostic studies available. It also provides a systematic and cost-effective approach to the differential diagnosis of nongap metabolic acidosis.

  18. Impedance Spectroscopy and FTIR Studies of PEG - Based Polymer Electrolytes

    Directory of Open Access Journals (Sweden)

    Anji Reddy Polu

    2011-01-01

    Full Text Available Ionic conductivity of poly(ethylene glycol (PEG - ammonium chloride (NH4Cl based polymer electrolytes can be enhanced by incorporating ceramic filler TiO2 into PEG-NH4Cl matrix. The electrolyte samples were prepared by solution casting technique. FTIR studies indicates that the complex formation between the polymer, salt and ceramic filler. The ionic conductivity was measured using impedance spectroscopy technique. It was observed that the conductivity of the electrolyte varies with TiO2 concentration and temperature. The highest room temperature conductivity of the electrolyte of 7.72×10−6 S cm-1 was obtained at 15% by weight of TiO2 and that without TiO2 filler was found to be 9.58×10−7 S cm−1. The conductivity has been improved by 8 times when the TiO2 filler was introduced into the PEG–NH4Cl electrolyte system. The conductance spectra shows two distinct regions: a dc plateau and a dispersive region. The temperature dependence of the conductivity of the polymer electrolytes seems to obey the VTF relation. The conductivity values of the polymer electrolytes were reported and the results were discussed. The imaginary part of dielectric constant (εi decreases with increase in frequency in the low frequency region whereas frequency independent behavior is observed in the high frequency region.

  19. Alkaline solid polymer electrolytes and their application to rechargeable batteries; Electrolytes solides polymeres alcalins application aux generateurs electrochimiques rechargeables

    Energy Technology Data Exchange (ETDEWEB)

    Guinot, S

    1996-03-15

    A new family of solid polymer electrolytes (SPE) based on polyoxyethylene (POE), KOH and water is investigated in view of its use in rechargeable batteries. After a short review on rechargeable batteries, the preparation of various electrolyte compositions is described. Their characterization by differential scanning calorimetry (DSC), thermogravimetric analysis, X-ray diffraction and microscopy confirm a multi-phasic structure. Conductivity measurements give values up to 10 sup -3 S cm sup -1 at room temperature. Their use in cells with nickel as negative electrode and cadmium or zinc as positive electrode has been tested; cycling possibility has been shown to be satisfactory. (C.B.) 113 refs.

  20. Solid-state electric double layer capacitors fabricated with plastic crystal based flexible gel polymer electrolytes: Effective role of electrolyte anions

    International Nuclear Information System (INIS)

    Suleman, Mohd; Kumar, Yogesh; Hashmi, S.A.

    2015-01-01

    Flexible gel polymer electrolyte (GPE) thick films incorporated with solutions of lithium trifluoromethanesulfonate (Li-triflate or LiTf) and lithium bis trifluoromethane-sulfonimide (LiTFSI) in a plastic crystal succinonitrile (SN), entrapped in poly(vinylidine fluoride-co-hexafluoropropylene) (PVdF-HFP) have been prepared and characterized. The films have been used as electrolytes in the electrical double layer capacitors (EDLCs). Coconut-shell derived activated carbon with high specific surface area (∼2100 m 2 g −1 ) and mixed (micro- and meso-) porosity has been used as EDLC electrodes. The structural, thermal, and electrochemical characterization of the GPEs have been performed using scanning electron microscopy (SEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), impedance measurements and cyclic voltammetry. The high ionic conductivity (∼10 −3 S cm −1 at 25 °C), good electrochemical stability window (>4.0 V) and flexible nature of the free-standing films of GPEs show their competence in the fabrication of EDLCs. The EDLCs have been tested using electrochemical impedance spectroscopy, cyclic voltammetry, and charge–discharge studies. The EDLCs using LiTf based electrolyte have been found to give higher values of specific capacitance, specific energy, power density (240–280 F g −1 , ∼39 Wh kg −1 and ∼19 kW kg −1 , respectively) than the EDLC cell with LiTFSI based gel electrolyte. EDLCs have been found to show stable performance for ∼10 4 charge–discharge cycles. The comparative studies indicate the effective role of electrolyte anions on the capacitive performance of the solid-state EDLCs. - Graphical abstract: Display Omitted - Highlights: • Flexible EDLCs with succinonitrile based gel electrolyte membranes are reported. • Anionic size of salts in gel electrolytes plays important role on capacitive performance. • Li-triflate incorporated gel electrolyte shows better performance over LiTFSI-based gel.

  1. Solid-state electric double layer capacitors fabricated with plastic crystal based flexible gel polymer electrolytes: Effective role of electrolyte anions

    Energy Technology Data Exchange (ETDEWEB)

    Suleman, Mohd; Kumar, Yogesh; Hashmi, S.A., E-mail: sahashmi@physics.du.ac.in

    2015-08-01

    Flexible gel polymer electrolyte (GPE) thick films incorporated with solutions of lithium trifluoromethanesulfonate (Li-triflate or LiTf) and lithium bis trifluoromethane-sulfonimide (LiTFSI) in a plastic crystal succinonitrile (SN), entrapped in poly(vinylidine fluoride-co-hexafluoropropylene) (PVdF-HFP) have been prepared and characterized. The films have been used as electrolytes in the electrical double layer capacitors (EDLCs). Coconut-shell derived activated carbon with high specific surface area (∼2100 m{sup 2} g{sup −1}) and mixed (micro- and meso-) porosity has been used as EDLC electrodes. The structural, thermal, and electrochemical characterization of the GPEs have been performed using scanning electron microscopy (SEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), impedance measurements and cyclic voltammetry. The high ionic conductivity (∼10{sup −3} S cm{sup −1} at 25 °C), good electrochemical stability window (>4.0 V) and flexible nature of the free-standing films of GPEs show their competence in the fabrication of EDLCs. The EDLCs have been tested using electrochemical impedance spectroscopy, cyclic voltammetry, and charge–discharge studies. The EDLCs using LiTf based electrolyte have been found to give higher values of specific capacitance, specific energy, power density (240–280 F g{sup −1}, ∼39 Wh kg{sup −1} and ∼19 kW kg{sup −1}, respectively) than the EDLC cell with LiTFSI based gel electrolyte. EDLCs have been found to show stable performance for ∼10{sup 4} charge–discharge cycles. The comparative studies indicate the effective role of electrolyte anions on the capacitive performance of the solid-state EDLCs. - Graphical abstract: Display Omitted - Highlights: • Flexible EDLCs with succinonitrile based gel electrolyte membranes are reported. • Anionic size of salts in gel electrolytes plays important role on capacitive performance. • Li-triflate incorporated gel electrolyte shows better

  2. Potassium toxicity at low serum potassium levels with refeeding syndrome.

    Science.gov (United States)

    Vemula, Praveen; Abela, Oliver G; Narisetty, Keerthy; Rhine, David; Abela, George S

    2015-01-01

    Refeeding syndrome is a life-threatening condition occurring in severely malnourished patients after initiating feeding. Severe hypophosphatemia with reduced adenosine triphosphate production has been implicated, but little data are available regarding electrolyte abnormalities. In this case, we report electrocardiographic changes consistent with hyperkalemia during potassium replacement after a serum level increase from 1.9 to 2.9 mEq/L. This was reversed by lowering serum potassium back to 2.0 mEq/L. In conclusion, the patient with prolonged malnutrition became adapted to low potassium levels and developed potassium toxicity with replacement. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Prognostic value of repeated serum CA 125 measurements in first trimester pregnancy.

    Science.gov (United States)

    Schmidt, T; Rein, D T; Foth, D; Eibach, H W; Kurbacher, C M; Mallmann, P; Römer, T

    2001-08-01

    To assess the diagnostic value of maternal CA 125 in patients with symptomatic first trimester pregnancy and to evaluate the prognostic significance of CA 125 versus beta-hCG in early pregnancies with intact fetal heartbeat, complicated by vaginal bleeding. Two prospective open-label studies with longitudinal follow-up in the second trial. Academic Department of Obstetrics and Gynecology, University of Cologne. Study 1: 168 patients presenting between gestational weeks 6 and 12 with: extrauterine pregnancy, 29; missed abortion, 50; incomplete spontaneous abortion, 38; imminent abortion, 33; and normal pregnancy (no history of endometriosis or ovarian mass), 18. Study 2: Fifty consecutive patients with vaginal bleeding during gestational weeks 6-12 all of whom having demostrable fetal heartbeat. Eighteen patients finally aborted whereas the remainder had normally continuing pregnancy until term. Study 1: Single serum determinations of CA 125 and beta-hCG were correlated with the different disorders observed. Study 2: Two sequential measurements of serum CA 125 and beta-hCG performed within a 5-7 days interval were related to the outcome of pregnancy as indicated by changes of the ultrasound presentation, miscarriage, future hospitalization, or delivery. Study 1: Patients with vaginal bleeding generally had higher median CA 125 values (38 IU/ml; range 1.3-540) compared to non-bleeding patients (17.8 IU/ml; range 1.0-157). No statistically significant differences in regard to median serum CA 125 levels between symptomatic and normal pregnancies occurred: normal pregnancy, 25.5 IU/ml (range 3.2-97); ectopic pregnancy, 26 IU/ml (range 1.3-157); missed abortion, 19.1IU/ml (range 1-242); threatened abortion, 48 IU/ml (range 5.2-540); spontaneous abortion, 40 IU/ml (range 5.4-442). Study 2: Initial CA 125 levels did not differ significantly between both groups of patients with 27/32 non-aborters and 13/18 aborters showing concentrations below 65 IU/ml. After 5-7 days, CA

  4. The clinical value of measurement of serum leptin, α1-acid glycoprotein and alphal-antitrypsine levels in patients with lung cancer

    International Nuclear Information System (INIS)

    Hu Xingrong; Deng Zihui; Xue Hui; Yan Guangtao

    2010-01-01

    Objective: To investigate the early diagnostic value of measurement of changes of serum leptin, α 1 -acid glycoprotein (AAG) and alphal-antitrypsine (α 1 AT)levels in patients with lung cancer. Methods: Serum leptin (with RIA)and serum AAG and α 1 AT (with ELISA) levels were determined in 89 patients with lung cancer and 60 controls. Results: The serum levels of leptin, AAG and α 1 AT in patients with lung cancer were significantly higher than those in the controls. No correlations among the investigated serum parameters were demonstrated. Conclusion: Serum leptin, AAG and α 1 AT levels are higher in patients with lung cancer. They may play inde-pendent roles in the development of lung cancer. Detection of the serum concentrations of leptin, AAG and α 1 AT is valuable for early diagnosis of lung cancer. (authors)

  5. [Expression and differential diagnostic value of serum microRNA for invasive pulmonary aspergillosis].

    Science.gov (United States)

    Wen, Z N; Ling, Z G; Huang, Y; Li, X

    2017-04-12

    Objective: To explore the expression and the clinical diagnostic value of serum miR-21 for invasive pulmonary aspergillosis (IPA). Methods: Outpatients and inpatients from the Fourth Affiliated Hospital of Guangxi Medical University were included in the study during June 2014 to September 2015. The IPA group had 40 patients, male 22, female 18, aged 55-68 years (mean 60 ), while the control groups included 50 patients with pulmonary tuberculosis [male 23, female 27, aged 50-62 years (mean 55 )], 50 patients with lung cancer [male 30, female 20, aged 55-70 years (mean 62)], and 50 healthy controls [male 25, female 25, aged 50-67 years (mean 60) ]. Serum were obtained and the levels of miR-21 and galactomannan (GM test) and (1, 3)-beta-D-glucan (G test) were measured. The related indexes were analyzed by logistic regression and ROC curves. Results: The serum miR-21 expression in IPA and lung cancer patients were increased, the median values ( P (25) and P (75)) being 0.42(0.31, 0.62)and 0.80(0.65, 0.94) respectively, both of which were significantly higher than those of the healthy controls [ 0.09(0.04, 0.15)] and the tuberculosis cases [ 0.08(0.03, 0.16)], P tuberculosis cases and lung cancer cases were 0.914, 0.897 and 0.863 respectively, with the Youden index being 0.780, 0.700 and 0.605 respectively. The serum levels of miR-21 in between 0.198 and 0.723 had preferable diagnostic accuracy. ROC analysis for miR-21 in IPA compared to healthy controls showed that the AUCs of miR-21 combined with G test or GM test were 0.992 and 0.966 respectively, the sensitivity being 95% (38/40) and 93% (37/40) respectively, the specificity being 98% (49/50) and 96% (48/50) respectively, and the Youden index being 0.930 and 0.885 respectively. If miR-21 was combined with G test and GM test, the AUC was 0.994, the sensitivity and the specificity being 98% (38/40) and 96% (48/50) respectively, and the Youden index increased to 0.935. ROC analysis for miR-21 in IPA compared to

  6. Utilization of aloe vera extract as electrolyte for an accumulator

    Science.gov (United States)

    Azmi, F.; Sispriatna, D.; Ikhsan, K.; Masrura, M.; Azzahra, S. S.; Mahidin; Supardan, M. D.

    2018-03-01

    Aloe vera contains acid, which has the potential to generate electric current. The objective of this research is to study the potency of aloe vera extract as electrolyte for an accumulator. Experimental results showed that aloe vera extract has no a stable value of voltage and currency. The voltage and currency of aloe vera extract were reduced more than 50% for 60 minutes. Then, aloe vera extract was mixed with accu zuur to produce electrolyte solution. The mixture composition of aloe vera extract to accu zuur of 50:50 (v/v) generated stable voltage and currency. The experimental results showed the potential use of aloe vera extract to reduce the chemicals used in a conventional electrolyte solution.

  7. Process to remove rare earth from IFR electrolyte

    International Nuclear Information System (INIS)

    Ackerman, J.P.; Johnson, T.R.

    1994-01-01

    The invention is a process for the removal of rare earths from molten chloride electrolyte salts used in the reprocessing of integrated fast reactor fuel (IFR). The process can be used either continuously during normal operation of the electrorefiner or as a batch process. The process consists of first separating the actinide values from the salt before purification by removal of the rare earths. After replacement of the actinides removed in the first step, the now-purified salt electrolyte has the same uranium and plutonium concentration and ratio as when the salt was removed from the electrorefiner. 1 fig

  8. The predictive value of mean serum uric acid levels for developing prediabetes.

    Science.gov (United States)

    Zhang, Qing; Bao, Xue; Meng, Ge; Liu, Li; Wu, Hongmei; Du, Huanmin; Shi, Hongbin; Xia, Yang; Guo, Xiaoyan; Liu, Xing; Li, Chunlei; Su, Qian; Gu, Yeqing; Fang, Liyun; Yu, Fei; Yang, Huijun; Yu, Bin; Sun, Shaomei; Wang, Xing; Zhou, Ming; Jia, Qiyu; Zhao, Honglin; Huang, Guowei; Song, Kun; Niu, Kaijun

    2016-08-01

    We aimed to assess the predictive value of mean serum uric acid (SUA) levels for incident prediabetes. Normoglycemic adults (n=39,353) were followed for a median of 3.0years. Prediabetes is defined as impaired fasting glucose (IFG), impaired glucose tolerance (IGT), or impaired HbA1c (IA1c), based on the American Diabetes Association criteria. Serum SUA levels were measured annually. Four diagnostic strategies were used to detect prediabetes in four separate analyses (Analysis 1: IFG. Analysis 2: IFG+IGT. Analysis 3: IFG+IA1c. Analysis 4: IFG+IGT+IA1c). Cox proportional hazards regression models were used to assess the relationship between SUA quintiles and prediabetes. C-statistic was additionally used in the final analysis to assess the accuracy of predictions based upon baseline SUA and mean SUA, respectively. After adjustment for potential confounders, the hazard ratios (95% confidence interval) of prediabetes for the highest versus lowest quintile of mean SUA were 1.22 (1.10, 1.36) in analysis 1; 1.59 (1.23, 2.05) in analysis 2; 1.62 (1.34, 1.95) in analysis 3 and 1.67 (1.31, 2.13) in analysis 4. In contrast, for baseline SUA, significance was only reached in analyses 3 and 4. Moreover, compared with baseline SUA, mean SUA value was associated with a significant increase in the C-statistic (Pprediabetes risk, and showed better predictive ability for prediabetes than baseline SUA. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Serum reference value of two potential doping candidates-myostatin and insulin-like growth factor-I in the healthy young male.

    Science.gov (United States)

    Han, Der-Sheng; Huang, Chi-Huang; Chen, Ssu-Yuan; Yang, Wei-Shiung

    2017-01-01

    Myostatin negatively regulates muscle growth, and its inhibition by suitable proteins can increase muscle bulk and exercise performance. However, the reference values of serum myostatin in athletes performing strength training are still lacking. A cross-sectional study recruiting28 male collegiate athletes performing strength training and 29 age-matched normal controls was conducted. The serum concentration of myostatin and insulin-like growth factor 1 (IGF-1), grip strength, and body composition were the main outcome measures. We used regression models to analyze the correlation between serum markers and the physiological parameters. The athlete group had greater height, weight, body mass index (BMI), fat mass percentage, fat-free mass, muscle mass, waist girth, grip strength, and estimated daily energy expenditure. The IGF-1 concentration was higher in the athlete group (324 ± 80 vs. 263 ± 134 ng/ml), but the myostatin levels did not differ (12.1 ± 3.7 vs. 12.4 ± 3.5 ng/ml). The reference value for IGF-1 among the healthy young males was 293 ± 114 ng/ml, correlated with age and height; the value for myostatin was 12.3 ± 3.6 ng/ml, correlated negatively with BMI, fat mass percentage, and waist girth after adjustment for age. Myostatin level is negatively related to fat percentage, and serum IGF-1 is positively related to height. The reference values could provide a basis for future doping-related study.

  10. Serum bilirubin value predicts hospital admission in carbon monoxide-poisoned patients. Active player or simple bystander?

    Directory of Open Access Journals (Sweden)

    Gianfranco Cervellin

    Full Text Available OBJECTIVES: Although carbon monoxide poisoning is a major medical emergency, the armamentarium of recognized prognostic biomarkers displays unsatisfactory diagnostic performance for predicting cumulative endpoints. METHODS: We performed a retrospective and observational study to identify all patients admitted for carbon monoxide poisoning during a 2-year period. Complete demographical and clinical information, along with the laboratory data regarding arterial carboxyhemoglobin, hemoglobin, blood lactate and total serum bilirubin, was retrieved. RESULTS: The study population consisted of 38 poisoned patients (23 females and 15 males; mean age 39±21 years. Compared with discharged subjects, hospitalized patients displayed significantly higher values for blood lactate and total serum bilirubin, whereas arterial carboxyhemoglobin and hemoglobin did not differ. In a univariate analysis, hospitalization was significantly associated with blood lactate and total serum bilirubin, but not with age, sex, hemoglobin or carboxyhemoglobin. The diagnostic performance obtained after combining the blood lactate and total serum bilirubin results (area under the curve, 0.90; 95% CI, 0.81-0.99; p<0.001 was better than that obtained for either parameter alone. CONCLUSION: Although it remains unclear whether total serum bilirubin acts as an active player or a bystander, we conclude that the systematic assessment of bilirubin may, alongside lactate levels, provide useful information for clinical decision making regarding carbon monoxide poisoning.

  11. Structural and optical characterization of PVA:KMnO4 based solid polymer electrolyte

    Directory of Open Access Journals (Sweden)

    Omed Gh. Abdullah

    Full Text Available Solid polymer electrolyte films of polyvinyl alcohol (PVA doped with a different weight percent of potassium permanganate (KMnO4 were prepared by standard solution cast method. XRD and FTIR techniques were performed for structural study. Complex formation between the PVA polymer and KMnO4 salt was confirmed by Fourier transform infrared (FTIR spectroscopy. The description of crystalline nature of the solid polymer electrolyte films has been confirmed by XRD analysis. The UV-Visible absorption spectra were analyzed in terms of absorption formula for non-crystalline materials. The fundamental optical parameters such as optical band gap energy, refractive index, optical conductivity, and dielectric constants have been investigated and showed a clear dependence on the KMnO4 concentration. The observed value of optical band gap energy for pure PVA is about 6.27 eV and decreases to a value 3.12 eV for the film sample formed with 4 wt% KMnO4 salt. The calculated values of refractive index and the dielectric constants of the polymer electrolyte films increase with increasing KMnO4 content. Keywords: Solid polymer electrolyte, XRD analysis, FTIR study, Optical band gap, Dielectric constant, Refractive index

  12. The effect of low serum bicarbonate values on the onset of action of local anesthesia with vertical infraclavicular brachial plexus block in patients with End-stage renal failure

    Directory of Open Access Journals (Sweden)

    Al-mustafa Mahmoud

    2010-01-01

    Full Text Available Vertical infraclavicular brachial plexus block is utilized in patients with chronic renal failure at the time of creation of an arterio-venous fistula (AVF. The aim of this study is to test the effect of impaired renal function, with the resulting deranged serum electrolytes and blood gases, on the success rate and the onset of action of the local anesthetics used. In this prospective clinical study, we investigated the effect of the serum levels of sodium, potassium, urea, crea-tinine, pH, and bicarbonate on the onset of action of a mixture of lidocaine and bupivacaine administered to create infraclavicular brachial plexus block. A total of 31 patients were studied. The success rate of the block was 93.5 % (29 patients. The mean onset time for impaired or re-duced sensation was found to be 8.9 ± 4.7 mins and for complete loss of sensation, was 21.2 ± 6.7 mins. There was no significant association with serum sodium, potassium, urea, creatinine or the blood pH level (P> 0.05. The bivariate correlation between serum bicarbonate level and the partial and complete sensory loss was -0.714 and -0.433 respectively, with significant correlation (P= 0.00, 0.019. Our study suggests that infraclavicular block in patients with chronic renal failure carries a high success rate; the onset of the block is delayed in patients with low serum bicarbonate levels.

  13. Electrolyte materials - Issues and challenges

    International Nuclear Information System (INIS)

    Balbuena, Perla B.

    2014-01-01

    Electrolytes are vital components of an electrochemical energy storage device. They are usually composed of a solvent or mixture of solvents and a salt or a mixture of salts which provide the appropriate environment for ionic conduction. One of the main issues associated with the selection of a proper electrolyte is that its electronic properties have to be such that allow a wide electrochemical window - defined as the voltage range in which the electrolyte is not oxidized or reduced - suitable to the battery operating voltage. In addition, electrolytes must have high ionic conductivity and negligible electronic conductivity, be chemically stable with respect to the other battery components, have low flammability, and low cost. Weak stability of the electrolyte against oxidation or reduction leads to the formation of a solid-electrolyte interphase (SEI) layer at the surface of the cathode and anode respectively. Depending on the materials of the electrolyte and those of the electrode, the SEI layer may be composed by combinations of organic and inorganic species, and it may exert a passivating role. In this paper we discuss the current status of knowledge about electrolyte materials, including non-aqueous liquids, ionic liquids, solid ceramic and polymer electrolytes. We also review the basic knowledge about the SEI layer formation, and challenges for a rational design of stable electrolytes

  14. Ionic conductivity in polyethylene-b-poly(ethylene oxide)/lithium perchlorate solid polymer electrolytes

    International Nuclear Information System (INIS)

    Guilherme, L.A.; Borges, R.S.; Moraes, E. Mara S.; Silva, G. Goulart; Pimenta, M.A.; Marletta, A.; Silva, R.A.

    2007-01-01

    The ionic conductivity and phase arrangement of solid polymeric electrolytes based on the block copolymer polyethylene-b-poly(ethylene oxide) (PE-b-PEO) and LiClO 4 have been investigated. One set of electrolytes was prepared from copolymers with 75% of PEO units and another set was based on a blend of copolymer with 50% PEO units and homopolymers. The differential scanning calorimetry (DSC) results, for electrolytes based on the copolymer with 75% of PEO units, were dominated by the PEO phase. The PEO block crystallinity dropped and the glass transition increased with salt addition due to the coordination of the cation by PEO oxygen. The conductivity for copolymers 75% PEO-based electrolyte with 15 wt% of salt was higher than 10 -5 S/cm at room temperature and reached to 10 -3 S/cm at 100 deg. C on a heating measurement. The blend of PE-b-PEO (50% PEO)/PEO/PE showed a complex thermal behavior with decoupled melting of the blocks and the homopolymers. Upon salt addition the endotherms associated with PEO domains disappeared and the PE crystals remained untouched. The conductivity results were limited at 100 deg. C to values close to 10 -4 S/cm and at room temperature values close to 3 x 10 -6 S/cm were obtained for the 15 wt% salt electrolyte. Raman study showed that the ionic association of the highly concentrated blend electrolytes at room temperature is not significant. Therefore, the lower values of conductivity in the case of the blend with 50% PEO can be assigned to the higher content of PE domains leading to a morphology with lower connectivity for ionic conduction both in the crystalline and melted state of the PE domains

  15. Effects of experimentally induced intestinal obstruction on the electrolyte profile in dogs

    International Nuclear Information System (INIS)

    Dar, E.M.; Khan, M.A.; Mehmood, A.K.

    2004-01-01

    This study was conducted to quantitatively asses the changes in serum electrolyte profile after experimentally induced upper and lower intestinal obstruction in dogs. Ten dogs of either sex ranging in weight from 20-25 Kg were selected. After thorough physical examination, de-worming and vaccination they were randomly divided into 3 groups. Groups A and B comprised of four animals each while group C had two animals. After preparing the operation site, upper intestinal obstruction was induced in animals of group A and lower intestinal obstruction was induced in all animals of group B through mid line laparotomy under general anesthesia. Animals of group C were kept as control without induction of any obstruction. Proper post-operative care was given to the operated animals. Blood samples were collected from all animals at an interval of 24 hours and evaluated to observe changes in serum sodium, potassium and chloride levels. The results of this study showed marked decline in electrolyte levels in animals of both groups A and B, however this decline was more severe and rapid in group A than group B, while group c acted normally. It can be concluded that upper intestinal obstruction is more fatal in its consequences than lower intestinal obstruction, which is relatively less dangerous in producing its ill effects. (author)

  16. Changes in electrolytes and blood gas after transfusion of irradiated MAP

    International Nuclear Information System (INIS)

    Miyao, Hideki; Katayama, Akinori; Okamoto, Yumi; Koyama, Kaoru; Kawasaki, Jun; Kawazoe, Taro

    2001-01-01

    This study was undertaken to investigate the changes in recipient serum electrolytes and arterial blood gas after irradiated blood transfusion. We measured electrolytes and arterial blood gas before and after the transfusion during elective surgery in 55 patients. The mean blood loss was 1,477 g and the mean transfused blood unit of irradiated Mannitol-Adenine-Phosphate (MAP) was 5.9 units. Potassium concentration increased from 3.8 to 4.2 mEq·l -1 . A total of 187 units, which had been stored for 12.3±3.5 days after donation and for 5.1±3.8 days after irradiation, was used. There was a significant correlation between the storage period from the day of irradiation and the potassium concentration of the supernatant (r=0.56, p<0.0001). This study recommends that a safe transfusion rate of irradiated blood should be determined because the high potassium concentration of irradiated blood may lead to lethal complications in case of rapid transfusion. (author)

  17. On the theory of the electroreduction of solid oxide electrolytes

    International Nuclear Information System (INIS)

    Chebotin, V.N.; Brajnin, M.I.; Solov'eva, L.M.; Pakhnutov, I.A.; Lukach, Yu.S.

    1986-01-01

    The process of direct current passage through the cell with MOsub(2)+MeOsub(r) solid electrolyte (M-Zr, Hf, Ce, Th; Me-Ca, Sr, Sc, Y, lanthanides), a blockage cathode and a reversible anode is considered; it leads to electrolyte deviation from stoichiometric composition to insufficient oxygen content. The degree of this deviation and n-type electron conductivity proportional to it, depending on coordinate and time, is described by the nonlinear differential equation of the diffusion type. Electron conductivity of the electrolyte near the cathode increases in time approximating to the limiting value proportional to current conducted. As the distance to the cathode increases electron conductivity reduces by the exponential law, which transforms to a linear one in due course

  18. Electrochemical Model for Ionic Liquid Electrolytes in Lithium Batteries

    International Nuclear Information System (INIS)

    Yoo, Kisoo; Deshpande, Anirudh; Banerjee, Soumik; Dutta, Prashanta

    2015-01-01

    ABSTRACT: Room temperature ionic liquids are considered as potential electrolytes for high performance and safe lithium batteries due to their very low vapor pressure and relatively wide electrochemical and thermal stability windows. Unlike organic electrolytes, ionic liquid electrolytes are molten salts at room temperature with dissociated cations and anions. These dissociated ions interfere with the transport of lithium ions in lithium battery. In this study, a mathematical model is developed for transport of ionic components to study the performance of ionic liquid based lithium batteries. The mathematical model is based on a univalent ternary electrolyte frequently encountered in ionic liquid electrolytes of lithium batteries. Owing to the very high concentration of components in ionic liquid, the transport of lithium ions is described by the mutual diffusion phenomena using Maxwell-Stefan diffusivities, which are obtained from atomistic simulation. The model is employed to study a lithium-ion battery where the electrolyte comprises ionic liquid with mppy + (N-methyl-N-propyl pyrrolidinium) cation and TFSI − (bis trifluoromethanesulfonyl imide) anion. For a moderate value of reaction rate constant, the electric performance results predicted by the model are in good agreement with experimental data. We also studied the effect of porosity and thickness of separator on the performance of lithium-ion battery using this model. Numerical results indicate that low rate of lithium ion transport causes lithium depleted zone in the porous cathode regions as the porosity decreases or the length of the separator increases. The lithium depleted region is responsible for lower specific capacity in lithium-ion cells. The model presented in this study can be used for design of optimal ionic liquid electrolytes for lithium-ion and lithium-air batteries

  19. Value of serum IgG4 in the diagnosis of IgG4-related disease and in differentiation from rheumatic diseases and other diseases.

    Science.gov (United States)

    Yamamoto, Motohisa; Tabeya, Tetsuya; Naishiro, Yasuyoshi; Yajima, Hidetaka; Ishigami, Keisuke; Shimizu, Yui; Obara, Mikiko; Suzuki, Chisako; Yamashita, Kentaro; Yamamoto, Hiroyuki; Hayashi, Toshiaki; Sasaki, Shigeru; Sugaya, Toshiaki; Ishida, Tadao; Takano, Ken-Ichi; Himi, Tetsuo; Suzuki, Yasuo; Nishimoto, Norihiro; Honda, Saho; Takahashi, Hiroki; Imai, Kohzoh; Shinomura, Yasuhisa

    2012-06-01

    IgG4-related disease (IgG4-RD) is a novel disease entity that includes Mikulicz's disease, autoimmune pancreatitis (AIP), and many other conditions. It is characterized by elevated serum IgG4 levels and abundant IgG4-bearing plasmacyte infiltration of involved organs. We postulated that high levels of serum IgG4 would comprise a useful diagnostic tool, but little information is available about IgG4 in conditions other than IgG4-RD, including rheumatic diseases. Several reports have described cutoff values for serum IgG4 when diagnosing IgG4-RD, but these studies mostly used 135 mg/dL in AIP to differentiate from pancreatic cancer instead of rheumatic and other common diseases. There is no evidence for a cutoff serum IgG4 level of 135 mg/dL for rheumatic diseases and common diseases that are often complicated with rheumatic diseases. The aim of this work was to re-evaluate the usual cutoff serum IgG4 value in AIP (135 mg/dL) that is used to diagnose whole IgG4-RD in the setting of a rheumatic clinic by measuring serum IgG4 levels in IgG4-RD and various disorders. We therefore constructed ROC curves of serum IgG4 levels in 418 patients who attended Sapporo Medical University Hospital due to IgG4-RD and various rheumatic and common disorders. The optimal cut-off value of serum IgG4 for a diagnosis of IgG4-RD was 144 mg/dL, and the sensitivity and specificity were 95.10 and 90.76%, respectively. Levels of serum IgG4 were elevated in IgG4-RD, Churg-Strauss syndrome, multicentric Castleman's disease, eosinophilic disorders, and in some patients with rheumatoid arthritis, systemic sclerosis, chronic hepatitis, and liver cirrhosis. The usual cut-off value of 135 mg/dL in AIP is useful for diagnosing whole IgG4-RD, but high levels of serum IgG4 are sometimes observed in not only IgG4-RD but also other rheumatic and common diseases.

  20. Reference values for fasting serum resistin in healthy children and adolescents

    DEFF Research Database (Denmark)

    Lausten-Thomsen, Ulrik; Christiansen, Michael; Hedley, Paula Louise

    2017-01-01

    are needed for the risk stratification and interpretation of individual serum resistin concentrations. METHODS: A total of 1191 healthy, non-obese Danish schoolchildren (727 girls) aged 6-18years (median 11.9) were included. Fasting serum resistin concentrations were quantitated by Human Resistin ELISA...... in both boys (p=0.02) and girls (pFasting serum resistin concentrations differ between sexes...

  1. Solid polymer electrolyte on the basis of polyethylene carbonate-lithium perchlorate system

    International Nuclear Information System (INIS)

    Dukhanin, G.P.; Dumler, S.A.; Sablin, A.N.; Novakov, I.A.

    2009-01-01

    Reaction in the system polyethylene carbonate-lithium perchlorate was investigated by IR spectroscopy, differential thermal and X-ray structural analyses. Specific electric conductivity of the prepared composition has been measured. Solid polymer electrolytes on the basis of polyethylene carbonate have conducting properties as electrolytes on the basis of unmodified polyethylene oxide. Compositions of polyethylene carbonate : LiClO 4 =10 : 1Al 2 O 3 -ZrO 2 possess maximum value of electrical conductivity. Activation energies of the process is calculated for all investigated compositions, and dependence of these values from concentration of lithium perchlorate is established

  2. Maternal serum fructosamine values after delivery ofmacrosomic ...

    African Journals Online (AJOL)

    expl.anation for this discrepancy is that the half-lives of these. 1. Brudenell M, Wilds PLo Medical and Surgical Problems in Obstetrics. Bristol: John Wright, 1984: 120-124. 2. Baker JR, O'Connor JP, Metcalf P, Lawson MR, Johnson RN. Oinical usefulness of estimation of serum frucrosamine concentration as a screening.

  3. TRANSPORT MECHANISM STUDIES OF CHITOSAN ELECTROLYTE SYSTEMS

    International Nuclear Information System (INIS)

    Navaratnam, S.; Ramesh, K.; Ramesh, S.; Sanusi, A.; Basirun, W.J.; Arof, A.K.

    2015-01-01

    ABSTRACT: Knowledge of ion-conduction mechanisms in polymers is important for designing better polymer electrolytes for electrochemical devices. In this work, chitosan-ethylene carbonate/propylene carbonate (chitosan-EC/PC) system with lithium acetate (LiCH 3 COO) and lithium triflate (LiCF 3 SO 3 ) as salts were prepared and characterized using electrochemical impedance spectroscopy to study the ion-conduction mechanism. It was found that the electrolyte system using LiCF 3 SO 3 salt had a higher ionic conductivity, greater dielectric constant and dielectric loss value compared to system using LiCH 3 COO at room temperature. Hence, it may be inferred that the system incorporated with LiCF 3 SO 3 dissociated more readily than LiCH 3 COO. Conductivity mechanism for the systems, 42 wt.% chitosan- 28 wt.% LiCF 3 SO 3 -30 wt.% EC/PC (CLT) and 42 wt.% chitosan-28 wt.% LiCH 3 COO-30 wt.% EC/PC (CLA) follows the overlapping large polaron tunneling (OLPT) model. Results show that the nature of anion size influences the ionic conduction of chitosan based polymer electrolytes. The conductivity values of the CLA system are found to be higher than that of CLT system at higher temperatures. This may be due to the vibration of bigger triflate anions would have hindered the lithium ion movements. FTIR results show that lithium ions can form complexation with polymer host which would provide a platform for ion hopping

  4. How Solid-Electrolyte Interphase Forms in Aqueous Electrolytes.

    Science.gov (United States)

    Suo, Liumin; Oh, Dahyun; Lin, Yuxiao; Zhuo, Zengqing; Borodin, Oleg; Gao, Tao; Wang, Fei; Kushima, Akihiro; Wang, Ziqiang; Kim, Ho-Cheol; Qi, Yue; Yang, Wanli; Pan, Feng; Li, Ju; Xu, Kang; Wang, Chunsheng

    2017-12-27

    Solid-electrolyte interphase (SEI) is the key component that enables all advanced electrochemical devices, the best representative of which is Li-ion battery (LIB). It kinetically stabilizes electrolytes at potentials far beyond their thermodynamic stability limits, so that cell reactions could proceed reversibly. Its ad hoc chemistry and formation mechanism has been a topic under intensive investigation since the first commercialization of LIB 25 years ago. Traditionally SEI can only be formed in nonaqueous electrolytes. However, recent efforts successfully transplanted this concept into aqueous media, leading to significant expansion in the electrochemical stability window of aqueous electrolytes from 1.23 V to beyond 4.0 V. This not only made it possible to construct a series of high voltage/energy density aqueous LIBs with unprecedented safety, but also brought high flexibility and even "open configurations" that have been hitherto unavailable for any LIB chemistries. While this new class of aqueous electrolytes has been successfully demonstrated to support diversified battery chemistries, the chemistry and formation mechanism of the key component, an aqueous SEI, has remained virtually unknown. In this work, combining various spectroscopic, electrochemical and computational techniques, we rigorously examined this new interphase, and comprehensively characterized its chemical composition, microstructure and stability in battery environment. A dynamic picture obtained reveals how a dense and protective interphase forms on anode surface under competitive decompositions of salt anion, dissolved ambient gases and water molecule. By establishing basic laws governing the successful formation of an aqueous SEI, the in-depth understanding presented in this work will assist the efforts in tailor-designing better interphases that enable more energetic chemistries operating farther away from equilibria in aqueous media.

  5. The prognostic value of serum neuron-specific enolase in traumatic brain injury: systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Feng Cheng

    Full Text Available BACKGROUND: Several studies have suggested that neuron-specific enolase (NSE in serum may be a biomarker of traumatic brain injury. However, whether serum NSE levels correlate with outcomes remains unclear. The purpose of this review was to evaluate the prognostic value of serum NSE protein after traumatic brain injury. METHODS: PubMed and Embase were searched for relevant studies published up to October 2013. Full-text publications on the relationship of NSE to TBI were included if the studies concerned patients with closed head injury, NSE levels in serum after injury, and Glasgow Outcome Scale (GOS or Extended GOS (GOSE scores or mortality. Study design, inclusion criteria, assay, blood sample collection time, NSE cutoff, sensitivity and specificity of NSE for mortality prediction (if sufficient information was provided to calculate these values, and main outcomes were recorded. RESULTS: Sixteen studies were eligible for the current meta-analysis. In the six studies comparing NSE concentrations between TBI patients who died and those who survived, NSE concentrations correlated with mortality (M.D. 0.28, 95% confidence interval (CI, 0.21 to 0.34; I2 55%. In the eight studies evaluating GOS or GOSE, patients with unfavorable outcomes had significantly higher NSE concentrations than those with favorable outcomes (M.D. 0.24, 95% CI, 0.17 to 0.31; I2 64%. From the studies providing sufficient data, the pooled sensitivity and specificity for mortality were 0.79 and 0.50, and 0.72 and 0.66 for unfavorable neurological prognosis, respectively. The areas under the SROC curve (AUC of NSE concentrations were 0.73 (95% CI, 0.66-0.80 for unfavorable outcome and 0.76 (95% CI, 0.62-0.90 for mortality. CONCLUSIONS: Mortality and unfavorable outcome were significantly associated with greater NSE concentrations. In addition, NSE has moderate discriminatory ability to predict mortality and neurological outcome in TBI patients. The optimal discrimination cutoff

  6. The serum anion gap in the evaluation of acid-base disorders: what are its limitations and can its effectiveness be improved?

    Science.gov (United States)

    Kraut, Jeffrey A; Nagami, Glenn T

    2013-11-01

    The serum anion gap has been utilized to identify errors in the measurement of electrolytes, to detect paraproteins, and, most relevant to the nephrologist, to evaluate patients with suspected acid-base disorders. In regard to the latter purpose, traditionally an increased anion gap is identified when it exceeds the upper limit of normal for a particular clinical laboratory measurement. However, because there is a wide range of normal values (often 8-10 mEq/L), an increase in anion concentration can be present in the absence of an increased anion gap. In addition, the type of retained anion can affect the magnitude of the increase in anion gap relative to change in serum [HCO3(-)] being greater with lactic acidosis compared with ketoacidosis. This review examines the methods of calculation of the serum anion gap in textbooks and published literature, the effect of perturbations other than changes in acid-base balance, and its effectiveness in identifying mild and more severe disturbances in acid-base balance. Limitations of the present methods of determining the normal anion gap and change in the anion gap are highlighted. The possibility of identifying the baseline value for individuals to optimize the use of the calculation in the detection of metabolic acidosis is suggested.

  7. Constructions of aluminium electrolytic cells

    International Nuclear Information System (INIS)

    Galushkin, N.V.

    1995-01-01

    This chapter of monograph is devoted to constructions of aluminium electrolytic cells. Therefore, the general characteristic and classification of aluminium electrolytic cells was considered. The anode and cathode structure was studied. The lining of cathode casing, the process of collection of anode gases, electrolytic cell cover, and electrical insulation was studied as well. The installation and dismantling of aluminium electrolytic cells was described.

  8. Value of preoperative serum LC3 and MMPs combined with TSH detection in diagnosis of papillary thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Yan-Fei Lu

    2016-03-01

    Full Text Available Objective: To study the value of preoperative serum LC3 and MMPs combined with TSH detection in diagnosis of papillary thyroid carcinoma and provide reference for clinical diagnosis and treatment. Methods: A total of 80 cases of patients with papillary thyroid carcinoma treated in our hospital from March 2010 to March 2014 were analyzed, and serum TSH, MMP2/9, TIMP1/2 and LC3 levels of patients before operation were detected by ELISA. Healthy subjects and patients with benign neoplasm of thyroid during the same period were taken as control. Results: Serum TSH, MMP2, MMP9 and LC3 levels in patients with papillary thyroid carcinoma significantly increased, TIMP1 and TIMP2 levels significantly decreased, and compared with healthy subjects and patients with benign neoplasm of thyroid, there were significant statistical differences; at the same time, above parameters in serum were not related to gender, but closely related to age, clinical stage and diameter of tumor as well as lymph node. Conclusion: Preoperative detection of serum LC3 and MMPs combined with TSH levels has important reference significance in diagnosis of papillary thyroid carcinoma.

  9. Normal values of glomerular filtration rate in geriatrics in Bandung and its correlation with serum cystatin-C levels

    International Nuclear Information System (INIS)

    Resnaldi, A.; Yuliani, A.; Hidayat, B.; Kartamihardja, A.H.S.

    2007-01-01

    Full text: Determination of the normal values of glomerular filtration rate (GFR) is an essential part of the evaluation of patient with kidney disease. GFR almost linearly decreases with age at a mean annual rate of 0.8 ml/min/1.73 m2 over the age of 30 years old. According to NHANES III mean GFR for population with age > 60 years was 80 mL/min/1.73 m2. It is recommended for each centre to determine their own normal values of GFR for different age groups particularly in geriatric population. Recently, serum cystatin-C has been proposed as a new endogenous marker of glomerular filtration rate. Aim of the study was to determination of normal values of glomerular filtration rate (GFR) in geriatrics in Bandung and its correlation with serum Cystatin-C levels. Subjects were 24 males and 36 females (mean age 66.71 ± 6.7 years; range 60-87 yrs), without any renal and/or systemic disease. Creatinine clearance was estimated by using Cockroft-Gault formula and serum cystatin-C level were determined by using particle enhanced immunonephelometric method, while GFR values were determined by external body counting methods using Tc-99m DTPA ( Gates' methods ). Pearson correlation was used to determine correlation between variables and a P value < 0.05 is considered significant. Results and Discussion. Mean total GFR was 67.57 ml/min/1.73 m2 (SD ± 16.02), range from 45 to 100 ml/min/1.73 m2. Mean total GFR for male was 69.46 ml/min/1.73 m2, and female was 66.31 ml/min/1.73 m2, the difference was statistically significant (p < 0.05). The results were lower than NHANES III values. There was a better correlation between total GFR and cystatin-C level (r = -0.522 and p < 0.001) compared to total GFR and creatinine clearance (r 0.306 and p < 0.005). Mean creatinine clearance was 57.93 ml/min and serum cystatin-C was 0.97 mg/dl, the correlation was statistically significant (r -0.414 and p < 0.005). Conclusions: The normal values of GFR in geriatric population in Bandung were 69

  10. Ultrasonographically determined renal values and comparisons to serum biochemistry renal variables in aged semi-captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Kirberger, Robert M; Tordiffe, Adrian S W

    2017-11-06

    Cheetahs in captivity have a high prevalence of chronic renal diseases. We ultrasonographically evaluated the renal volumes, a variety of renal dimensions, interarcuate artery resistive indices (RI) as well as aortic diameters and the length of the ventral aspect of the 6th lumbar vertebrae in 27 aged semi-captive anesthetized cheetahs. Renal size, dimensions and ratios were compared to urine specific gravity, serum creatinine and urea values. There were minimal differences for all values between left and right kidneys. Mean kidney length was 65.1 mm (range 55.2-76.9) with left kidney length ratios to L6 length being 1.60 (range 1.27-2.06) and to the aortic diameter 7.69 (range 4.54-10.72). Significant correlations between left renal length as well as length:L6 ratio to creatinine values were found ((r - 0.66) and (r - 0.60) respectively). The mean RI values of the different sedation/anesthetic protocols ranged from 0.46-0.55. Left renal length and L6 ventral vertebral body length as well as left kidney RI values should be routinely measured in all cheetah abdominal ultrasound examinations. These measurements, together with serum creatinine, urea and urine specific gravity values may be relatively sensitive indicators of early renal pathology in the absence of gross ultrasonographic changes.

  11. An induced current method for measuring zeta potential of electrolyte solution-air interface.

    Science.gov (United States)

    Song, Yongxin; Zhao, Kai; Wang, Junsheng; Wu, Xudong; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing

    2014-02-15

    This paper reports a novel and very simple method for measuring the zeta potential of electrolyte solution-air interface. When a measuring electrode contacts the electrolyte solution-air interface, an electrical current will be generated due to the potential difference between the electrode-air surface and the electrolyte solution-air interface. The amplitude of the measured electric signal is linearly proportional to this potential difference; and depends only on the zeta potential at the electrolyte solution-air interface, regardless of the types and concentrations of the electrolyte. A correlation between the zeta potential and the measured voltage signal is obtained based on the experimental data. Using this equation, the zeta potential of any electrolyte solution-air interface can be evaluated quickly and easily by inserting an electrode through the electrolyte solution-air interface and measuring the electrical signal amplitude. This method was verified by comparing the obtained results of NaCl, MgCl2 and CaCl2 solutions of different pH values and concentrations with the zeta potential data reported in the published journal papers. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Efficient Electrolytes for Lithium–Sulfur Batteries

    International Nuclear Information System (INIS)

    Angulakshmi, Natarajan; Stephan, Arul Manuel

    2015-01-01

    This review article mainly encompasses on the state-of-the-art electrolytes for lithium–sulfur batteries. Different strategies have been employed to address the issues of lithium–sulfur batteries across the world. One among them is identification of electrolytes and optimization of their properties for the applications in lithium–sulfur batteries. The electrolytes for lithium–sulfur batteries are broadly classified as (i) non-aqueous liquid electrolytes, (ii) ionic liquids, (iii) solid polymer, and (iv) glass-ceramic electrolytes. This article presents the properties, advantages, and limitations of each type of electrolytes. Also, the importance of electrolyte additives on the electrochemical performance of Li–S cells is discussed.

  13. Efficient Electrolytes for Lithium-Sulfur Batteries

    Directory of Open Access Journals (Sweden)

    Natarajan eAngulakshmi

    2015-05-01

    Full Text Available This review article mainly encompasses on the state-of-the-art electrolytes for lithium–sulfur batteries. Different strategies have been employed to address the issues of lithium-sulfur batteries across the world. One among them is identification of electrolytes and optimization of their properties for the applications in lithium-sulfur batteries. The electrolytes for lithium-sulfur batteries are broadly classified as (i non-aqueous liquid electrolytes, (ii ionic liquids, (iii solid polymer and (iv glass-ceramic electrolytes. This article presents the properties, advantages and limitations of each type of electrolytes. Also the importance of electrolyte additives on the electrochemical performance of Li-S cells is discussed.

  14. Efficient Electrolytes for Lithium–Sulfur Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Angulakshmi, Natarajan [Department of Materials Science and Engineering, Politecnico di Torino, Turin (Italy); Stephan, Arul Manuel, E-mail: arulmanuel@gmail.com [Central Electrochemical Research Institute (CSIR-CECRI), Karaikudi (India)

    2015-05-21

    This review article mainly encompasses on the state-of-the-art electrolytes for lithium–sulfur batteries. Different strategies have been employed to address the issues of lithium–sulfur batteries across the world. One among them is identification of electrolytes and optimization of their properties for the applications in lithium–sulfur batteries. The electrolytes for lithium–sulfur batteries are broadly classified as (i) non-aqueous liquid electrolytes, (ii) ionic liquids, (iii) solid polymer, and (iv) glass-ceramic electrolytes. This article presents the properties, advantages, and limitations of each type of electrolytes. Also, the importance of electrolyte additives on the electrochemical performance of Li–S cells is discussed.

  15. Novel Nonflammable Electrolytes for Secondary Magnesium Batteries and High Voltage Electrolytes for Electrochemcial Supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Brian

    2008-12-30

    Magnesium has been used successfully in primary batteries, but its use in rechargeable cells has been stymied by the lack of suitable non-aqueous electrolyte that can conduct Mg+2 species, combined with poor stripping and plating properties. The development of a suitable cathode material for rechargeable magnesium batteries has also been a roadblock, but a nonflammable electrolyte is key. Likewise, the development of safe high voltage electrochemical supercapaitors has been stymied by the use of flammable solvents in the liquid electrolyte; to wit, acetonitrile. The purpose of the research conducted in this effort was to identify useful compositions of magnesium salts and polyphosphate solvents that would enable magnesium ions to be cycled within a secondary battery design. The polyphosphate solvents would provide the solvent for the magnesium salts while preventing the electrolyte from being flammable. This would enable these novel electrolytes to be considered as an alternative to THF-based electrolytes. In addition, we explored several of these solvents together with lithium slats for use as high voltage electrolytes for carbon-based electrochemical supercapacitors. The research was successful in that: 1) Magnesium imide dissolved in a phosphate ester solvent that contains a halogented phosphate ester appears to be the preferred electrolyte for a rechargeable Mg cell. 2) A combination of B-doped CNTs and vanadium phosphate appear to be the cathode of choice for a rechargeable Mg cell by virtue of higher voltage and better reversibility. 3) Magnesium alloys appear to perform better than pure magnesium when used in combination with the novel polyphosphate electrolytes. Also, this effort has established that Phoenix Innovation's family of phosphonate/phosphate electrolytes together with specific lithium slats can be used in supercapacitor systems at voltages of greater than 10V.

  16. Piperidinium tethered nanoparticle-hybrid electrolyte for lithium metal batteries

    KAUST Repository

    Korf, Kevin S.

    2014-06-23

    We report on the synthesis of novel piperidinium-based ionic liquid tethered nanoparticle hybrid electrolytes and investigate their physical and electrochemical properties. Hybrid electrolytes based on the ionic liquid 1-methyl-1-propylpiperidinium bis(trifluoromethanesulfone) imide covalently tethered to silica nanoparticles (SiO2-PP-TFSI) were blended with propylene carbonate-1 M lithium bis(trifluoromethanesulfone) imide (LiTFSI). We employed NMR analysis to confirm the successful creation of the hybrid material. Dielectric and rheological measurements show that these electrolytes exhibit exceptional room-temperature DC ionic conductivity (10-2 to 10 -3 S cm-1) as well as high shear mechanical moduli (105 to 106 Pa). Lithium transference numbers were found to increase with particle loading and to reach values as high as 0.22 at high particle loadings where the particle jam to form a soft glassy elastic medium. Analysis of lithium electrodeposits obtained in the hybrid electrolytes using SEM and EDX spectra show that the SiO2-PP-TFSI nanoparticles are able to smooth lithium deposition and inhibit lithium dendrite proliferation in Li metal batteries. LTOSiO2-PP-TFSI/PC in 1 M LiTFSILi half-cells based on the SiO2-PP-TFSI hybrid electrolytes exhibit attractive voltage profiles and trouble-free extended cycling behavior over more than 1000 cycles of charge and discharge. This journal is © the Partner Organisations 2014.

  17. Diagnostic value of soluble CD163 serum levels in patients suspected of meningitis: comparison with CRP and procalcitonin

    DEFF Research Database (Denmark)

    Knudsen, Troels Bygum; Larsen, Klaus; Kristiansen, Thomas Birk

    2007-01-01

    The aim of the study was to evaluate and compare the diagnostic value of sCD163 serum levels with CRP and PCT in meningitis and bacterial infection. An observational cohort study was conducted between February 2001 and February 2005. The study population comprised 55 patients suspected of meningi......The aim of the study was to evaluate and compare the diagnostic value of sCD163 serum levels with CRP and PCT in meningitis and bacterial infection. An observational cohort study was conducted between February 2001 and February 2005. The study population comprised 55 patients suspected...... marker for distinguishing bacterial infection from non-bacterial disease (specificity 0.91; sensitivity 0.47). However, the overall diagnostic accuracy of CRP (AUC =0.91) and PCT (AUC =0.87) were superior (p... infection, the AUC of sCD163 (0.83) did not differ significantly from those of CRP or PCT. All markers had AUCs CRP and PCT had high diagnostic value and were superior as markers of bacterial infection compared to s...

  18. Electrolyte for a lithium/thionyl chloride electric cell, a method of preparing said electrolyte and an electric cell which includes said electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Gabano, J.

    1983-03-01

    An electrolyte for an electric cell whose negative active material is constituted by lithium and whose positive active material is constituted by thionyl chloride. The electrolyte contains at least one solvent and at least one solute, said solvent being thionyl chloride and said solute being chosen from the group which includes lithium tetrachloroaluminate and lithium hexachloroantimonate. According to the invention said electrolyte further includes a complex chosen from the group which includes AlCl/sub 3/,SO/sub 2/ and SbCl/sub 5/,SO/sub 2/. The voltage rise of electric cells which include such an electrolyte takes negligible time.

  19. Predictive value study of serum STIM1 and Adropin contents in cardiovascular events and restenosis after PCI operation

    Directory of Open Access Journals (Sweden)

    Qiu-Wei Lin

    2016-02-01

    Full Text Available Objective: To study the predictive value of serum STIM1 and Adropin contents in cardiovascular events and restenosis after PCI operation. Methods: Single coronary artery lesion patients receiving percutaneous coronary intervention in our hospital from May 2014 to January 2015 were selected for study, 45 cases of patients with in-stent restenosis 6 months after PCI operation more than 50% were enrolled in ISR group, 85 cases of patients with instent restenosis no more than 50% were enrolled in NISR group, and then serum STIM1, Adropin and NO contents as well as endothelial progenitor cell content and endothelial microparticle number in peripheral blood of two groups were detected. Results: Serum STIM1 content of ISR group was significantly higher than that of NISR group and STIM1 content was positively correlated with lumen stenosis degree, and serum Adropin content of ISR group was significantly lower than that of NISR group and Adropin content was negatively correlated with lumen stenosis degree; endothelial progenitor cell content in peripheral blood and serum NO content of ISR group were less than those of NISR group, and endothelial microparticle number in peripheral blood was more than that of NISR group; serum STIM1 content was positively correlated with endothelial microparticle number in peripheral blood and negatively correlated with endothelial progenitor cell content in peripheral blood, and serum Adropin content was negatively correlated with endothelial microparticle number in peripheral blood and positively correlated with serum NO content. Conclusion: Serum STIM1 content increase and Adropin content decrease are related to the occurrence of cardiovascular events and restenosis after PCI operation, and the two molecules mainly affect endothelial cell function and endothelial progenitor cell homing.

  20. Predictive value of early serum beta-human chorionic gonadotrophin for the successful outcome in women undergoing in vitro fertilization

    Directory of Open Access Journals (Sweden)

    Neeta Singh

    2013-01-01

    Full Text Available Aims: Pregnancies achieved by in vitro fertilization (IVF are at increased risk of adverse outcome. The main objective of this study was to evaluate the predictive value of β-human chorionic gonadotrophin (β-HCG and age of the patient for the successful outcome in IVF. Materials and Methods: A retrospective study was done in 139 pregnancies after IVF at single IVF center from June 2007 to July 2012. The age of the patient and initial serum values of β-HCG on day 14 of embryo transfer were correlated with ongoing pregnancy (>12 weeks gestation. Results: The β-HCG level on day 14 of more than 347 mIU/ml has a sensitivity of 72.2% and specificity of 73.6% in prediction of pregnancy beyond 12 weeks period of gestation. Positive likelihood ratio (LR is 2.74 and negative LR is 0.37, (receiver operating characteristic area = 0.79. Discussion: In IVF cycles, there is a lot of stress on the couples while the cycle is going on. There was a positive correlation between the higher values of early serum β-HCG levels and ongoing pregnancy. Hence, it can be used as an independent predictor of a successful outcome of IVF cycle. Conclusion: We concluded from our study that early serum β-HCG can be used as a predictor of a successful outcome in IVF.

  1. High-performance electrolyte in the presence of dextrose and its derivatives for aluminum electrolytic capacitors

    Science.gov (United States)

    Tsai, Ming-Liao; Lu, Yi-Fang; Do, Jing-Shan

    Dextrose and its derivatives (e.g. glucose, gluconic acid and gluconic lactone) are added to modify the characteristics of electrolytes used in aluminum electrolytic capacitors. The results show that the conductivity and sparking voltage of the electrolytes are severely affected by the concentration of dextrose gluconic acid and gluconic lactone. In addition, the pH of the electrolyte is only slightly affected by the quantity of gluconic acid and gluconic lactone. The capacitance, dissipation factor, and leakage current of capacitors impregnated with the electrolytes prepared in this work are periodically measured under storage conditions and loading at 105 °C.

  2. Ceramic solid electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Goodenough, John B. [Center for Materials Science and Engineering, University of Texas at Austin, Austin, TX (United States)

    1997-02-15

    Strategies for the design of ceramic solid electrolytes are reviewed. Problems associated with stoichiometric and doped compounds are compared. In the illustration of design principles, emphasis is given to oxide-ion electrolytes for use in solid-oxide fuel cells, oxygen pumps, and oxygen sensors

  3. Cost-driven materials selection criteria for redox flow battery electrolytes

    Science.gov (United States)

    Dmello, Rylan; Milshtein, Jarrod D.; Brushett, Fikile R.; Smith, Kyle C.

    2016-10-01

    Redox flow batteries show promise for grid-scale energy storage applications but are presently too expensive for widespread adoption. Electrolyte material costs constitute a sizeable fraction of the redox flow battery price. As such, this work develops a techno-economic model for redox flow batteries that accounts for redox-active material, salt, and solvent contributions to the electrolyte cost. Benchmark values for electrolyte constituent costs guide identification of design constraints. Nonaqueous battery design is sensitive to all electrolyte component costs, cell voltage, and area-specific resistance. Design challenges for nonaqueous batteries include minimizing salt content and dropping redox-active species concentration requirements. Aqueous battery design is sensitive to only redox-active material cost and cell voltage, due to low area-specific resistance and supporting electrolyte costs. Increasing cell voltage and decreasing redox-active material cost present major materials selection challenges for aqueous batteries. This work minimizes cost-constraining variables by mapping the battery design space with the techno-economic model, through which we highlight pathways towards low price and moderate concentration. Furthermore, the techno-economic model calculates quantitative iterations of battery designs to achieve the Department of Energy battery price target of 100 per kWh and highlights cost cutting strategies to drive battery prices down further.

  4. Gel polymer electrolytes for batteries

    Science.gov (United States)

    Balsara, Nitash Pervez; Eitouni, Hany Basam; Gur, Ilan; Singh, Mohit; Hudson, William

    2014-11-18

    Nanostructured gel polymer electrolytes that have both high ionic conductivity and high mechanical strength are disclosed. The electrolytes have at least two domains--one domain contains an ionically-conductive gel polymer and the other domain contains a rigid polymer that provides structure for the electrolyte. The domains are formed by block copolymers. The first block provides a polymer matrix that may or may not be conductive on by itself, but that can soak up a liquid electrolyte, thereby making a gel. An exemplary nanostructured gel polymer electrolyte has an ionic conductivity of at least 1.times.10.sup.-4 S cm.sup.-1 at 25.degree. C.

  5. The prognostic value of serum S100B in patients with cutaneous melanoma: a meta-analysis.

    Science.gov (United States)

    Mocellin, Simone; Zavagno, Giorgio; Nitti, Donato

    2008-11-15

    S100B protein detected in the serum of patients with cutaneous melanoma has been long reported as a prognostic biomarker. However, no consensus exists on its implementation in the routine clinical setting. This study aimed to comprehensively and quantitatively summarize the evidence on the suitability of serum S100B to predict patients' survival. Twenty-two series enrolling 3393 patients with TNM stage I to IV cutaneous melanoma were reviewed. Standard meta-analysis methods were applied to evaluate the overall relationship between S100B serum levels and patients' survival (meta-risk). Serum S100B positivity was associated with significantly poorer survival (hazard ratio [HR] = 2.23, 95% CI: 1.92-2.58, p < 0.0001). Between-study heterogeneity was significant, which appeared to be related mainly to dissemination bias and the inclusion of patients with stage IV disease. Considering stage I to III melanoma (n = 1594), the meta-risk remained highly significant (HR = 2.28, 95% CI: 1.8-2.89; p < 0.0001) and studies' estimates were homogeneous. Subgroup analysis of series reporting multivariate survival analysis supported S100B as a prognostic factor independent of the TNM staging system. Our findings suggest that serum S100B detection has a clinically valuable independent prognostic value in patients with melanoma, with particular regard to stage I-III disease. Further investigation focusing on this subset of patients is justified and warranted before S100B can be implemented in the routine clinical management of melanoma. (c) 2008 Wiley-Liss, Inc.

  6. Lithium carbon batteries with solid polymer electrolyte; Accumulateur lithium carbone a electrolyte solide polymere

    Energy Technology Data Exchange (ETDEWEB)

    Andrieu, X.; Boudin, F. [Alcatel Alsthom Recherche, 91 - Marcoussis (France)

    1996-12-31

    The lithium carbon batteries studied in this paper use plasticized polymer electrolytes made with passive polymer matrix swollen by a liquid electrolyte with a high ionic conductivity (> 10{sup -3} S/cm at 25 deg. C). The polymers used to prepare the gels are polyacrylonitrile (PAN) and vinylidene poly-fluoride (PVdF). The electrochemical and physical properties of these materials are analyzed according to their composition. The behaviour of solid electrolytes with different materials of lithium ion insertion (graphite and LiNiO{sub 2}) are studied and compared to liquid electrolytes. The parameters taken into account are the reversible and irreversible capacities, the cycling performance and the admissible current densities. Finally, complete lithium ion batteries with gelled electrolytes were manufactured and tested. (J.S.) 2 refs.

  7. Lithium carbon batteries with solid polymer electrolyte; Accumulateur lithium carbone a electrolyte solide polymere

    Energy Technology Data Exchange (ETDEWEB)

    Andrieu, X; Boudin, F [Alcatel Alsthom Recherche, 91 - Marcoussis (France)

    1997-12-31

    The lithium carbon batteries studied in this paper use plasticized polymer electrolytes made with passive polymer matrix swollen by a liquid electrolyte with a high ionic conductivity (> 10{sup -3} S/cm at 25 deg. C). The polymers used to prepare the gels are polyacrylonitrile (PAN) and vinylidene poly-fluoride (PVdF). The electrochemical and physical properties of these materials are analyzed according to their composition. The behaviour of solid electrolytes with different materials of lithium ion insertion (graphite and LiNiO{sub 2}) are studied and compared to liquid electrolytes. The parameters taken into account are the reversible and irreversible capacities, the cycling performance and the admissible current densities. Finally, complete lithium ion batteries with gelled electrolytes were manufactured and tested. (J.S.) 2 refs.

  8. Observation of pH Value in Electrokinetic Remediation using various electrolyte (MgSO4, KH2PO4 and Na(NO3)) for Barren Acidic Soil at Ayer Hitam, Johor, Malaysia

    Science.gov (United States)

    Norashira, J.; Zaidi, E.; Aziman, M.; Saiful Azhar, A. T.

    2016-07-01

    Barren acidic soil collected at Ayer Hitam, Johor Malaysia was recorded at pH value of 2.36 with relative humidity of 86%. This pH value is not suitable for the growth of any plants especially for the soil stabilization purposes. Gradation weathering within the range of 4 to 6 indicates an incomplete/partial weathering process. The soil grade in this range is known as a black shale mudstone. Beside, this also influences to a factor of the high surface water runoff at this particular soil species. As the acidic pH become a major problem for soil fertilizing hence an appropriate technique was implemented known as using ‘Electrokinetic Remediation’, EKR. This technique has a great potential in changing the soil pH value from acidic to less acidic and also kept maintain the pH at the saturated rate of electrochemical process. This research study presents the monitoring data of pH value due to the effect of various electrolyte consist of 0.5M of MgSO4, KH2PO4, and Na(NO3). Here, the distilled water (DW) was used as reference solution. The electric field was provided by dipping two pieces of identical rectangular aluminum foil as anode and cathode. The EKR was conducted under a constant voltage gradient of 50 V/m across the sample bulk at 0.14 m length measured between both electrodes. The data collection was conducted during the total period of 7 days surveillance. The variation of pH values at the remediation area between anode and cathode for various type of electrolyte indicates that there are a significant saturated value as it reaches 7 days of treatment. During the analysis, it is found that the highest pH value at the remediation area after 7 days treatment using Na(NO3), KH2PO4 and MgSO4 was 3.93, 3.33 and 3.39 respectively. Hence from the last stage of pH value observation, it can be conclude that the best electrolyte for barren soil treatment is Na(NO3) whereby it contribute to highest pH value and turn the soil to be less acidic.

  9. Reference values for serum leptin in healthy non-obese children and adolescents.

    Science.gov (United States)

    Lausten-Thomsen, Ulrik; Christiansen, Michael; Louise Hedley, Paula; Esmann Fonvig, Cilius; Stjernholm, Theresa; Pedersen, Oluf; Hansen, Torben; Holm, Jens-Christian

    2016-11-01

    Adipokines are biologically active, low-molecular weight peptides, which play a major role in metabolic homeostasis in humans. Leptin has gained increasing attention in pediatrics as a biomarker for various metabolic pathologies. Yet, its usefulness is hampered by the relative lack of reference values from pediatric settings. Accordingly, this study aims to evaluate serum concentrations of leptin, soluble leptin receptor (sOB-R), and free leptin index (FLI) in healthy Danish schoolchildren aged 6-18 years and subsequently to establish reference intervals across sex and age groups. A total of 1193 healthy, non-obese Danish schoolchildren (730 girls, 463 boys) aged 6-18 years (median 11.9) were examined by trained medical staff. Serum leptin and sOB-R concentrations in venous fasting blood samples were quantitated by immunoassay. Percentile curves of leptin, sOB-R, and free leptin index were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Significant age and sex-dependent differences in circulating leptin levels were found. In boys, the median leptin concentration for all ages combined was 3.35 μg/L (95%-interval: 0.71-22.47) and in girls, it was 9.89 ng/L (95%-interval: 2.06-41.49). For SOB-R, no sex-specific difference was found, and the median sOB-R concentration was 8.24 μg/L (IQR: 3.58-23.74; range: < 1.56-744.15). We demonstrated an age-dependent correlation with both serum leptin concentration and free leptin index with a gradual and significant increase in girls throughout childhood and adolescence and a significantly higher leptin concentration and free leptin index bell-shaped peak in early adolescence in boys.

  10. Proton Pump Inhibitors and Serum Magnesium Levels in Patients With Torsades de Pointes

    Directory of Open Access Journals (Sweden)

    Pietro E. Lazzerini

    2018-04-01

    Full Text Available Background: Torsades de pointes (TdP is a life-threatening ventricular tachycardia occurring in long QT-syndrome patients. It usually develops when multiple QT-prolonging factors are concomitantly present, more frequently drugs and electrolyte imbalances. Since proton–pump inhibitors (PPIs-associated hypomagnesemia is an increasingly recognized adverse event, PPIs were recently included in the list of drugs with conditional risk of TdP, despite only few cases of TdP in PPI users have been reported so far.Objectives: Aim of the present study is to evaluate whether PPI-induced hypomagnesemia actually has a significant clinical impact on the risk of TdP in the general population.Methods: Forty-eight unselected patients who experienced TdP were consecutively enrolled (2008-2017. Shortly after the first TdP episode, in those patients who did not receive magnesium sulfate and/or potassium or calcium replacement therapy, serum electrolytes were measured and their relationship with PPI usage analyzed.Results: Many patients (28/48, 58% were under current PPI treatment when TdP occurred. Among TdP patients in whom serum electrolyte determinations were obtained before replacement therapy (27/48, those taking PPIs had significantly lower serum magnesium levels than those who did not. Hypomagnesemia occurred in ~40% of patients receiving PPIs (6/14, in all cases after an extended treatment (>2 weeks. In patients taking PPIs the mean QT-prolonging risk factor number was significantly higher than in those who did not, a difference which was mainly driven by lower magnesium levels.Conclusions: In unselected TdP patients, PPI-induced hypomagnesemia was common and significantly contributed to their cumulative arrhythmic risk. By providing clinical support to current recommendations, our data confirm that more awareness is needed when a PPI is prescribed, specifically as regards the risk of life-threatening arrhythmias.

  11. Value of serum tenascin-C in patients with acute myocardial infarction

    African Journals Online (AJOL)

    Rania Gaber

    2015-10-09

    Oct 9, 2015 ... Aliquots of serum were delivered into Eppendorf tubes. Serum samples have been .... Tenascin-C induced by aldosterone-mediated inflammation. J · Cardiovasc .... nosis estimation and targeted therapy. Cell Adh Migr 2015 ...

  12. Value of serum PCT in early diagnosis of bacterial infection in patients with liver failure

    Directory of Open Access Journals (Sweden)

    WANG Chuanmin

    2017-06-01

    Full Text Available ObjectiveTo investigate the value of serum procalcitonin (PCT in early diagnosis of bacterial infection in patients with liver failure. MethodsA total of 463 patients with hepatitis B were selected from January to December, 2014, in the Department of Infectious Diseases, Taihe Hospital. According to the degree of liver injury, the patients were divided into four groups: mild liver injury group (n=120, moderate liver injury group (n=222, sever liver injury group (n=53, and liver failure group (n=68. Serum PCT was measured for all patients, and the white blood cell count (WBC and high-sensitivity C-reactive protein (hsCRP were measured for patients with liver failure. The clinical manifestations were observed and recorded. The t test was used for comparison of normally distributed continuous data, while the Kruskal-Wallis H test was used for non-normally distributed continuous data; the Mann-Whitney U test was used for pairwise comparison of continuous data. The chi-square test was used for comparison of categorical data. The receiver operating characteristic (ROC curve was used for the analysis of predictive value. ResultsThe liver failure group had a significantly higher PCT level than the severe liver injury group, moderate liver injury group, and mild liver injury group (0.81[0.34-2.15] vs 0.53[0.21-1.59], 0.35[010-1.18], and 0.17[0.10-0.60], χ2=25.091, P<0.05. The liver failure patients with PCT levels of <0.25 ng/ml (n=10, 0.25-0.5 ng/ml (n=10, and >0.5 ng/ml (n=48 had infection rates of 20%, 30%, and 66.7%, respectively, with a significant difference between the patients with a PCT level of >0.5 ng/ml and those with PCT levels of <0.25 ng/ml and 0.25-0.5 ng/ml (χ2=5631,4650,P=0018,0031. Among the liver failure patients, the infection cases had significantly higher PCT, WBC, and hsCRP than the non-infection cases (PCT: 3.72±1.33 ng/ml vs 0.34±0.12 ng/ml, t=-2.547, P=0.015; hsCRP: 16.70±7.03 mg

  13. Evaluation of apatite silicates as solid oxide fuel cell electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Marrero-Lopez, D. [Dpto. de Fisica Aplicada I, Laboratorio de Materiales y Superficies (Unidad Asociada al C.S.I.C.), Universidad de Malaga, 29071 Malaga (Spain); Dpto. de Quimica Inorganica, Universidad de La Laguna, 38200 La Laguna, Tenerife (Spain); Martin-Sedeno, M.C.; Aranda, M.A.G. [Dpto. de Quimica Inorganica, Universidad Malaga, 29071 Malaga (Spain); Pena-Martinez, J. [Dpto. de Quimica Inorganica, Universidad de La Laguna, 38200 La Laguna, Tenerife (Spain); Instituto de Energias Renovables, Parque Tecnologico, Universidad de Castilla La Mancha, 02006 Albacete (Spain); Ruiz-Morales, J.C.; Nunez, P. [Dpto. de Quimica Inorganica, Universidad de La Laguna, 38200 La Laguna, Tenerife (Spain); Ramos-Barrado, J.R. [Dpto. de Fisica Aplicada I, Laboratorio de Materiales y Superficies (Unidad Asociada al C.S.I.C.), Universidad de Malaga, 29071 Malaga (Spain)

    2010-05-01

    Apatite-type silicates have been considered as promising electrolytes for Solid Oxide Fuel Cells (SOFC); however studies on the potential use of these materials in SOFC devices have received relatively little attention. The lanthanum silicate with composition La{sub 10}Si{sub 5.5}Al{sub 0.5}O{sub 26.75} has been evaluated as electrolyte with the electrode materials commonly used in SOFC, i.e. manganite, ferrite and cobaltite as cathode materials and NiO-CGO composite, chromium-manganite and Sr{sub 2}MgMoO{sub 6} as anode materials. Chemical compatibility, area-specific resistance and fuel cell studies have been performed. X-ray powder diffraction (XRPD) analysis did not reveal any trace of reaction products between the apatite electrolyte and most of the aforementioned electrode materials. However, the area-specific polarisation resistance (ASR) of these electrodes in contact with apatite electrolyte increased significantly with the sintering temperature, indicating reactivity at the electrolyte/electrode interface. On the other hand, the ASR values are significantly improved using a ceria buffer layer between the electrolyte and electrode materials to prevent reactivity. Maximum power densities of 195 and 65 mWcm{sup -2} were obtained at 850 and 700 C, respectively in H{sub 2} fuel, using an 1 mm-thick electrolyte, a NiO-Ce{sub 0.8}Gd{sub 0.2}O{sub 1.9} composite as anode and La{sub 0.6}Sr{sub 0.4}Co{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}} as cathode materials. This fuel cell was tested for 100 h in 5%H{sub 2}-Ar atmosphere showing stable performance. (author)

  14. Clinical value of combined detection of serum tumor markers and whole body bone scan for diagnosis of bone metastases from breast cancer

    International Nuclear Information System (INIS)

    Gao Chao; Zhao Jing; Liu Desheng; Zhang Jingchuan; Ji Xuejing; Hou Xiancun

    2007-01-01

    Objective: To study the clinical value of serum tumor marker determination and whole body bone scan for diagnosis of bone metastases from breast cancer. Methods: Serum tumor markers (CA15-3, CEA, TSGF)were detected with GLIA and whole body bone scan were investigated by SPECT in 124 breast cancer patients. Results: In 124 patients, 38 patients were diagnosed as positive for bone metastases with whole body bone scan. The positive predicting values of CA15-3, CEA, TSGF were 76.78%, 80% and 82.14%, and the negative predicting values of CA15-3, GEA, TSGF were 82.41%, 86.74% and 84.29% respectively. The levels of CA15-3, CEA, TSGF in patients with bone metastases were significantly higher than those in patients without metastasis and the controls (P<0.01). Conclusion: Determination of levels of serum tumor markers CA15-3, CEA, TSGF is helpful for diagnosis of bone metastases from breast cancer. Combined detection of GA15-3, CEA, TSGF could increase the sensitivity and accuracy of diagnosing bone metastases. (authors)

  15. Preparation and characterization of nanocomposite polymer electrolytes poly(vinylidone fluoride)/nanoclay

    Energy Technology Data Exchange (ETDEWEB)

    Rahmawati, Suci A.; Sulistyaningsih,; Putro, Alviansyah Z. A.; Widyanto, Nugroho F.; Jumari, Arif; Purwanto, Agus; Dyartanti, Endah R., E-mail: endahrd@uns.ac.id [Research Group of Battery & Advanced Material, Department of Chemical Engineering, Sebelas Maret University, Jl. Ir. Sutami 36 A Kentingan, Surakarta Indonesia 57126 (Indonesia)

    2016-02-08

    Polymer electrolytes are defined as semi solid electrolytes used as separator in lithium ion battery. Separator used as medium for transfer ions and to prevent electrical short circuits in battery cells. To obtain the optimal battery performance, separator with high porosity and electrolyte uptake is required. This can reduce the resistance in the transfer of ions between cathode and anode. The main objective of this work is to investigate the impact of different solvent (Dimethyl acetamide (DMAc), N-methyl-2-pyrrolidone (NMP) and dimethyl formamide (DMF)), pore forming agent poly(vinylpyrolidone) (PVP) and nanoclay as filler in addition of membrane using phase inversion method on the morphology, porosity, electrolyte uptake and degree of crystallinity. The membrane was prepared by the phase inversion method by adding PVP and Nanoclay using different solvents. The phase inversion method was prepared by dissolving Nanoclay and PVP in solvent for 1-2 hours, and then add the PVDF with stirring for 4 hours at 60°C. The membranes were characterized by porosity test, electrolyte uptake test, scanning electron microscope (SEM), and X-ray diffraction (XRD). The results showed that DMAc as solvent gives the highest value of porosity and electrolyte uptake. The addition of nanoclay and PVP enlarge the size of the pores and reduce the degree of crystallinity. So, the usage of DMAc as solvent is better than NMP or DMF.

  16. Initial study of Nickel Electrolyte for EnFACE Process

    Directory of Open Access Journals (Sweden)

    Tri Widayatno

    2015-03-01

    Full Text Available Nickel electrolyte for a micro-pattern transfer process without photolithography, EnFACE, has been developed. Previous work on copper deposition indicated that a conductivity of ~2.7 Sm-1 is required. Electrochemical parameters of electrolyte i.e. current density and overpotential are also crucial to govern a successful pattern replication. Therefore, the investigation focused on the measurement of physicochemical properties and electrochemical behaviour of the electrolyte at different nickel concentrations and complexing agents of chloride and sulfamate. Nickel electrolytes containing sulfamate, chloride and combined sulfamate-chloride with concentrations between 0.14 M and 0.3 M were investigated. Physicochemical properties i.e. pH and conductivity were measured to ensure if they were in the desired value. The electrochemical behaviour of the electrolytes was measured by polarisation experiments in a standard three-electrode cell. The working electrode was a copper disc (surface area of 0.196 cm2 and the counter electrode was platinum mesh. The potential was measured againts a saturated calomel reference electrode (SCE. The experiments were carried out at various scan rate and Rotating Disc Electrode (RDE rotation speed to see the effect of scan rate and agitation. Based on the measured physicochemical properties, the electrolyte of 0.19 M nickel sulfamate was chosen for experimentation. Polarisation curve of agitated solution suggested that overall nickel electrodeposition reaction is controlled by a combination of kinetics and mass transfer.  Reduction potential of nickel was in the range of -0.7 to -1.0 V. The corresponding current densities for nickel deposition were in the range of -0.1 to -1.5 mA cm-2.

  17. Carboxymethyl Carrageenan Based Biopolymer Electrolytes

    International Nuclear Information System (INIS)

    Mobarak, N.N.; Jumaah, F.N.; Ghani, M.A.; Abdullah, M.P.; Ahmad, A.

    2015-01-01

    data, which demonstrated that the ionic conductivity of the 20 wt.% LiNO 3 iota-based electrolytes was highly similar with the 30 wt.% LiNO 3 kappa-based electrolytes, with values of 5.85 × 10 −3 S cm −1 and 5.51 × 10 −3 S cm −1 , respectively. The lithium transference number for the carboxymethyl kappa carrageenan was higher than for the carboxymethyl iota carrageenan. Additionally, the carboxymethyl iota carrageenan and carboxymethyl kappa carrageenan films were electrochemically stable up to ∼3.0 and 3.1 V, respectively, which indicates that these solid biopolymer electrolytes are promising candidates for utilization in electrochemical devices

  18. Enhancing Capacity Performance by Utilizing the Redox Chemistry of the Electrolyte in a Dual-Electrolyte Sodium-Ion Battery.

    Science.gov (United States)

    Senthilkumar, Sirugaloor Thangavel; Bae, Hyuntae; Han, Jinhyup; Kim, Youngsik

    2018-05-04

    A strategy is described to increase charge storage in a dual electrolyte Na-ion battery (DESIB) by combining the redox chemistry of the electrolyte with a Na + ion de-insertion/insertion cathode. Conventional electrolytes do not contribute to charge storage in battery systems, but redox-active electrolytes augment this property via charge transfer reactions at the electrode-electrolyte interface. The capacity of the cathode combined with that provided by the electrolyte redox reaction thus increases overall charge storage. An aqueous sodium hexacyanoferrate (Na 4 Fe(CN) 6 ) solution is employed as the redox-active electrolyte (Na-FC) and sodium nickel Prussian blue (Na x -NiBP) as the Na + ion insertion/de-insertion cathode. The capacity of DESIB with Na-FC electrolyte is twice that of a battery using a conventional (Na 2 SO 4 ) electrolyte. The use of redox-active electrolytes in batteries of any kind is an efficient and scalable approach to develop advanced high-energy-density storage systems. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The Value of Serum NR2 Antibody in Prediction of Post-Cardiopulmonary Resuscitation Survival

    Directory of Open Access Journals (Sweden)

    Ali Bidari

    2015-07-01

    Full Text Available Introduction: N-methyl-D-aspartate receptor subunits antibody (NR2-ab is a sensitive marker of ischemic brain damage in clinical circumstances, such as cerebrovascular accidents. We aimed to assess the value of serum NR2-ab in predicting the post-cardiopulmonary resuscitation (CPR survival. Methods: In this cohort study, we examined serum NR2-ab levels 1 hour after the return of spontaneous circulation (ROSC in 49 successfully resuscitated patients. Patients with traumatic or asphyxic arrests, prior neurological insults, or major medical illnesses were excluded. Participants were followed until death or hospital discharge. Demographic data, coronary artery disease risk factors, time before initiation of CPR, and CPR duration were documented.  In addition, Glasgow coma scale (GCS, blood pressure, and survival status of patients were recorded at 1, 6, 24, and 72 hour(s after ROSC. Descriptive analyses were performed, and the Cox proportional hazard model was applied to assess if NR2-ab level is an independent predictive factor of survival. Results: 49 successfully resuscitated patients were evaluated; 27 (55% survived to hospital discharge, 4 (8.1% were in vegetative state, 10 (20.4% were physically disabled, and 13 (26.5% were physically functional. Within 72 hours of ROSC all of the 12 NR2-ab positive patients died. In contrast, 31 (84% of the NR2-ab negative patients survived. Sensitivity, specificity, positive and negative likelihood ratios of NR2-ab in prediction of survival were 54.5% (95%CI=32.7%-74.9%, 100% (95%CI=84.5%-100%, infinite, and 45.5% (95%CI=28.8%-71.8%, respectively. Subsequent analysis showed that both NR2-ab status and GCS were independent risk factors of death. Conclusions: A positive NR2-ab serum test 1 hour after ROSC correlated with lower 72-hour survival. Further studies are required to validate this finding and demonstrate the value of a quantitative NR2-ab assay and its optimal time of measurement.

  20. PROGNOSTIC VALUE OF THE BASELINE VALUES OF SERUM TESTOSTERONE AND FREE ANDROGEN INDEX IN PATIENTS WITH PROSTATE CANCER

    Directory of Open Access Journals (Sweden)

    M. E. Grigoryev

    2012-01-01

    Full Text Available The growing incidence of prostate cancer (PC and its variable nature are an important problem today. PC is distinguished by its latent ability in many cases, which makes its screening difficult.Prostate-specific antigen (PSA is one of the most common tumor markers of PC, which are used for mass male screening. However, the detection rate of PC in men with normal PSA values is also very high. This promotes an active search for new markers and predictors of PC.The effect of androgens on hormonal carcinogenesis in the prostate suggests that the analysis of serum testosterone concentrations and free androgen index may be made in patients with low PSA levels in the early diagnosis and prognosis of PC.

  1. Double-membrane triple-electrolyte redox flow battery design

    Science.gov (United States)

    Yushan, Yan; Gu, Shuang; Gong, Ke

    2018-03-13

    A redox flow battery is provided having a double-membrane (one cation exchange membrane and one anion exchange membrane), triple-electrolyte (one electrolyte in contact with the negative electrode, one electrolyte in contact with the positive electrode, and one electrolyte positioned between and in contact with the two membranes). The cation exchange membrane is used to separate the negative or positive electrolyte and the middle electrolyte, and the anion exchange membrane is used to separate the middle electrolyte and the positive or negative electrolyte. This design physically isolates, but ionically connects, the negative electrolyte and positive electrolyte. The physical isolation offers great freedom in choosing redox pairs in the negative electrolyte and positive electrolyte, making high voltage of redox flow batteries possible. The ionic conduction drastically reduces the overall ionic crossover between negative electrolyte and positive one, leading to high columbic efficiency.

  2. Formation of a Spinel Coating on AZ31 Magnesium Alloy by Plasma Electrolytic Oxidation

    Science.gov (United States)

    Sieber, Maximilian; Simchen, Frank; Scharf, Ingolf; Lampke, Thomas

    2016-03-01

    Plasma electrolytic oxidation (PEO) is a common means for the surface modification of light metals. However, PEO of magnesium substrates in dilute electrolytes generally leads to the formation of coatings consisting of unfavorable MgO magnesium oxide. By incorporation of electrolyte components, the phase constitution of the oxide coatings can be modified. Coatings consisting exclusively of MgAl2O4 magnesium-aluminum spinel are produced by PEO in an electrolyte containing hydroxide, aluminate, and phosphate anions. The hardness of the coatings is 3.5 GPa on Martens scale on average. Compared to the bare substrate, the coatings reduce the corrosion current density in dilute sodium chloride solution by approx. one order of magnitude and slightly shift the corrosion potential toward more noble values.

  3. Competition of electrolytic hydrogen as secondary energy source

    International Nuclear Information System (INIS)

    Lartigue G, J.

    1993-01-01

    The hydrogen obtained by thermal dissociation of water and natural gas has been used, in general, by chemical industry since XIX Century. On the other hand, electrolytic hydrogen has only be used in the big scale, in the oil industry and, recently, in small scale, in the fuel cells. In spite of its great advantages with respect to electricity, the easiness for storage and inexpensive transportation, its massive use has been postponed own to the risky handle and the high cost. Nevertheless, this last inconvenient is being overcome in the recent design of electrolytic cells and with the use thermoelectric methods that use nuclear heat. In this work, some factors that influence the cost of electrolytic hydrogen and the value of the efficiency of the electrolytic cell which allows to match up the cost of hydrogen with electricity, as heat source, are presented. It is shown how, when the cost of the whole heat systems are considered (starting from electricity, hydrogen or natural gas), hydrogen can compete against with electricity if is obtained in cells with 83% of efficiency, which design is already available. In exchange, if apparent costs are compared (based only in the fares) without consider the prices of the kilns and its availability factors and maintenance, the efficiency of the cell should be greater than 93%, with technology still not available. (Author)

  4. POLYMER ELECTROLYTE MEMBRANE FUEL CELLS

    DEFF Research Database (Denmark)

    2001-01-01

    A method for preparing polybenzimidazole or polybenzimidazole blend membranes and fabricating gas diffusion electrodes and membrane-electrode assemblies is provided for a high temperature polymer electrolyte membrane fuel cell. Blend polymer electrolyte membranes based on PBI and various...... thermoplastic polymers for high temperature polymer electrolyte fuel cells have also been developed. Miscible blends are used for solution casting of polymer membranes (solid electrolytes). High conductivity and enhanced mechanical strength were obtained for the blend polymer solid electrolytes....... With the thermally resistant polymer, e.g., polybenzimidazole or a mixture of polybenzimidazole and other thermoplastics as binder, the carbon-supported noble metal catalyst is tape-cast onto a hydrophobic supporting substrate. When doped with an acid mixture, electrodes are assembled with an acid doped solid...

  5. Clinical diagnostic value of combined determination of serum TSGF, CEA, CYFRA21-1 and NSE levels in patients with lung cancer

    International Nuclear Information System (INIS)

    Sun Qihe; Sun Bin

    2008-01-01

    Objective: To explore the clinical diagnostic value of combined determination of serum TSGF, CEA, CYFRA21-1 and NSE levels in patients with lung cancer. Methods: The four serum tumor markers were determined with RIA or other methods in 179 patients with lung cancer, 48 patients with benign lung diseases and 51 controls. Results: The serum levels of all these four markers in the cancer patients were significantly higher (P<0.05-P<0.01) than those in patients with benign pulmonary disorders with the exception of: (1) Serum TSGF, CEA and NSE levels in patients with stage I and II squamous cell carcinoma (n=37) and (2) serum NSE levels in patients with stage I and II adenocarcinoma (n=32). As a whole, the levels of the markers increased along with the increase of the severity of the disease. Conclusion: For the early diagnosis of lung cancer, serum CYFRA21-1 levels determination is the most specific and serum NSE levels determination for diagnosis in patients with NSCLC is the least sensitive. The combined determination of tumor markers is the best choice. (authors)

  6. Conductivity behaviour of polymer gel electrolytes: Role of polymer

    Indian Academy of Sciences (India)

    Unknown

    of a container that can hold a large amount of solvent and as a result possesses the ... having high value of conductivity results in polymer gel electrolytes. They are ..... the availability of free ions provided by the acid. It gene- rally reaches a ...

  7. The role of electrolyte pH on phase evolution and magnetic properties of CoFeW codeposited films

    International Nuclear Information System (INIS)

    Ghaferi, Z.; Sharafi, S.; Bahrololoom, M.E.

    2016-01-01

    Highlights: • Deposition tends to anomalous-induced fashion at higher pH values. • The structure of the coatings depend on electrolyte pH effectively. • Grain size of two-phase structure films is lower than single-phase solid solutions. • Coercivity of the coatings changed by tungsten content and surface defects. • The highest pH value produced coating with superior magnetic behaviour. - Abstract: In this research, nanocrystalline Co–Fe–W alloy coatings were electrodeposited from a citrate-borate bath. The influence of electrolyte pH on the morphology, microstructure and magnetic properties of these films was also studied. By increasing pH value, the amount of iron content increased from 30 to 55 wt.% which indicates anomalous fashion at higher pH electrolytes. X-ray diffraction patterns showed that the structure of these films depend on electrolyte pH effectively. However, two-phase structure coatings showed smaller average grain size compared with one- phase solid solutions. Vibrating sample magnetometer measurements indicated that the coercivity of the coatings was in the range of 21–76 Oe. However, the highest pH value produced coating with superior magnetic behaviour. Microhardness of the coatings reached its maximum value at about 260HV which is referred to the highest tungsten content.

  8. Diagnostic value of combined determination of serum CEA, CA72-4 and TSGF levels in patients with gastric cancer

    International Nuclear Information System (INIS)

    Wang Yuyi; Gu Yan

    2007-01-01

    Objective: To explore the diagnostic value of combined determination of serum CEA, CA72-4 and TSGF levels for gastric cancer. Methods: Serum CEA, CA72-4(with RIA) and TSGF (with biochemistry)levels were measured in 31 patients with gastric cancer and 35 controls. Results: As a single tumor marker for diagnosis, the sensitivity of CEA, CA72-4 and TSGF was 23. 0%, 38.0%, 48.0% respectively and the specificity was 23.0%, 38.0%, 48.0% respectively with combined detection of the three markers and assuming two or more markers positive as diagnostic, the sensitivity would be 67.0% and specificity would be 88.0%. Conclusion: Combined determination of serum CEA, CA72-4 and TSGF levels could promote the clinical usefulness for diagnosis of gastric cancer. (authors)

  9. Starvation and refeeding in rats: effect on some parameters of energy metabolism and electrolytes and changes of hepatic tissue

    Directory of Open Access Journals (Sweden)

    Fatemeh Namazi

    Full Text Available Abstract: Regarding the importance of starvation and refeeding and the occurrence of refeeding syndrome in various conditions, the present study was conducted to investigate the effects of refeeding on some parameters of energy metabolism and electrolytes and changes of hepatic tissue in male Wistar rats. Fifty-seven rats were divided into six groups, having 6 to 11 rats. Food was provided ad-libitum until three months and then the first group was considered without starvation (day 0. Other rats were fasted for two weeks. Group 2 was applied to a group immediately after starvation (day 14. Groups 3 to 6 were refed in days 16 till 22, respectively. At the end of each period, blood and tissue samples were taken and histopathological and serum analysis, including serum electrolytes (calcium, phosphorus, sodium, potassium, the energy parameters (glucose, insulin, cortisol and the liver enzymes (ALT, AST, ALP were determined. Insulin decreased by starvation and then showed an increasing trend compared to starvation period, which the highest amount of this parameter was observed eight days post-refeeding. Serum glucose level showed the opposite pattern of insulin. Histopathological examination of the tissue sections revealed clear vacuoles after starvation and refeeding, in which the severity of lesions gradually decreased during refeeding. The cortisol level decreased by starvation and then increased during refeeding. Also, potassium and phosphorus concentrations declined by refeeding and the serum sodium and potassium levels were changed in the relatively opposite manner. The calcium level decreased by starvation and then increased during refeeding. These results could help recognize and remedy the refeeding syndrome.

  10. Multiple-membrane multiple-electrolyte redox flow battery design

    Science.gov (United States)

    Yan, Yushan; Gu, Shuang; Gong, Ke

    2017-05-02

    A redox flow battery is provided. The redox flow battery involves multiple-membrane (at least one cation exchange membrane and at least one anion exchange membrane), multiple-electrolyte (one electrolyte in contact with the negative electrode, one electrolyte in contact with the positive electrode, and at least one electrolyte disposed between the two membranes) as the basic characteristic, such as a double-membrane, triple electrolyte (DMTE) configuration or a triple-membrane, quadruple electrolyte (TMQE) configuration. The cation exchange membrane is used to separate the negative or positive electrolyte and the middle electrolyte, and the anion exchange membrane is used to separate the middle electrolyte and the positive or negative electrolyte.

  11. Nutritional value of the marine invertebrates Anemonia viridis and Haliothis tuberculata and effects on serum cholesterol concentration in ratsopen star

    Science.gov (United States)

    Gonzalez, M; Caride, B; Lamas, A; Taboada, C

    2001-09-01

    The purpose of this study was to determine the nutritional value of diets with protein from two marine species (Haliotis tuberculata and Anemonia viridis) as compared to a high-quality protein reference based on casein or casein supplemented with olive oil. We also investigated the effects of these diets on serum lipid levels. Male rats were fed these diets for 23 days. Protein quality indicators (true digestibility, net protein utilization, biological value) were similar to those obtained for casein-based feeds except for lower true digestibility and net protein utilization values for the Anemonia viridis feed. HDL-cholesterol level was significantly higher (p < 0.05) in the groups fed marine species or casein supplemented with olive oil than in the casein group. Total-cholesterol level was higher in the group fed Haliotis tuberculata fed than in the other groups. These results suggest that these marine species are a good protein source, and that they may have positive effects on serum cholesterol level.

  12. Serum magnesium is associated with the risk of dementia.

    Science.gov (United States)

    Kieboom, Brenda C T; Licher, Silvan; Wolters, Frank J; Ikram, M Kamran; Hoorn, Ewout J; Zietse, Robert; Stricker, Bruno H; Ikram, M Arfan

    2017-10-17

    To determine if serum magnesium levels are associated with the risk of all-cause dementia and Alzheimer disease. Within the prospective population-based Rotterdam Study, we measured serum magnesium levels in 9,569 participants, free from dementia at baseline (1997-2008). Participants were subsequently followed up for incident dementia, determined according to the DSM-III-R criteria, until January 1, 2015. We used Cox proportional hazard regression models to associate quintiles of serum magnesium with incident all-cause dementia. We used the third quintile as a reference group and adjusted for age, sex, Rotterdam Study cohort, educational level, cardiovascular risk factors, kidney function, comorbidities, other electrolytes, and diuretic use. Our study population had a mean age of 64.9 years and 56.6% were women. During a median follow-up of 7.8 years, 823 participants were diagnosed with all-cause dementia. Both low serum magnesium levels (≤0.79 mmol/L) and high serum magnesium levels (≥0.90 mmol/L) were associated with an increased risk of dementia (hazard ratio [HR] 1.32, 95% confidence interval [CI] 1.02-1.69, and HR 1.30, 95% CI 1.02-1.67, respectively). Both low and high serum magnesium levels are associated with an increased risk of all-cause dementia. Our results warrant replication in other population-based studies. © 2017 American Academy of Neurology.

  13. Changes in serum phosphate and potassium and their effects on mortality in malnourished African HIV-infected adults starting antiretroviral therapy and given vitamins and minerals in lipid-based nutritional supplements

    DEFF Research Database (Denmark)

    Rehman, Andrea Mary; Woodd, Susannah Louise; Heimburger, Douglas Corbett

    2017-01-01

    Malnourished HIV-infected patients starting antiretroviral therapy (ART) are at high risk of early mortality, some of which may be attributed to altered electrolyte metabolism. We used data from a randomised controlled trial of electrolyte-enriched lipid-based nutritional supplements to assess...... that changes in serum electrolytes, largely irrespective of the starting point and the direction of change, were more strongly associated with mortality than were absolute electrolyte levels. Although K and phosphate are required for tissue deposition during recovery from malnutrition, further studies...... are needed to determine whether specific supplements exacerbate physiologically adverse shifts in electrolyte levels during nutritional rehabilitation of ill malnourished HIV patients....

  14. Epoxy-silica hybrid organic–inorganic electrolytes with a high Li-ion conductivity

    International Nuclear Information System (INIS)

    Vélez, J.F.; Procaccini, R.A.; Aparicio, M.; Mosa, J.

    2013-01-01

    Organic–inorganic hybrid electrolytes were prepared by co-hydrolysis and co-condensation of 3-glycidoxipropyltrimethoxysilane (GPTMS) and tetraethyl orthosilicate (TEOS) doped with lithium acetate as self-supported materials and thin-films. The effects of the relative molar content of LiAc on the physicochemical properties of electrolytes, such as morphology, thermal, chemical and electrochemical properties were investigated. Two and four probes test cells were designed for comparative studies of ionic conductivity of hybrid electrolytes using electrochemical impedance spectroscopy (EIS). Similar ionic conductivities were obtained using both measurement methods, reaching a maximum ionic conductivity value of around 10 −6 S/cm at 25 °C. The conductivity mechanism presents Arrehenius behavior with the increase of the temperature from 25 °C to 120 °C. The electrochemical stability window is found to be in the range of 0–5 V, which ensures that hybrid organic–inorganic materials are potential electrolytes for solid-state rechargeable lithium ion batteries

  15. Permeability and Microstructure of Suspension Plasma-Sprayed YSZ Electrolytes for SOFCs on Various Substrates

    Science.gov (United States)

    Marr, Michael; Kesler, Olivera

    2012-12-01

    Yttria-stabilized zirconia electrolyte coatings for solid oxide fuel cells were deposited by suspension plasma spraying using a range of spray conditions and a variety of substrates, including finely structured porous stainless steel disks and cathode layers on stainless steel supports. Electrolyte permeability values and trends were found to be highly dependent on which substrate was used. The most gas-tight electrolyte coatings were those deposited directly on the porous metal disks. With this substrate, permeability was reduced by increasing the torch power and reducing the stand-off distance to produce dense coating microstructures. On the substrates with cathodes, electrolyte permeability was reduced by increasing the stand-off distance, which reduced the formation of segmentation cracks and regions of aligned and concentrated porosity. The formation mechanisms of the various permeability-related coating features are discussed and strategies for reducing permeability are presented. The dependences of electrolyte deposition efficiency and surface roughness on process conditions and substrate properties are also presented.

  16. CD4 lymphocyte counts and serum p24 antigen of no diagnostic value in monitoring HIV-infected patients with pulmonary symptoms

    DEFF Research Database (Denmark)

    Orholm, M; Nielsen, T L; Nielsen, Jens Ole

    1990-01-01

    The diagnostic value of the CD4 cell counts and the HIV p24 antigen were evaluated in a consecutive series of 105 HIV-infected patients experiencing 128 episodes of pulmonary symptoms which required bronchoscopy. One-third of patients with opportunistic infection (OI) had CD4 counts greater than ....... In conclusion, the CD4 cell counts and the presence of p24 antigen in serum had a very limited predictive value for the presence of OI in HIV-infected patients with pulmonary symptoms.......The diagnostic value of the CD4 cell counts and the HIV p24 antigen were evaluated in a consecutive series of 105 HIV-infected patients experiencing 128 episodes of pulmonary symptoms which required bronchoscopy. One-third of patients with opportunistic infection (OI) had CD4 counts greater than 0.......200 x 10(9)/l, and 60% of patients without OI had CD4 counts less than 0.200 x 10(9)/l; 47 and 42% of patients with and without OI, respectively, had detectable p24 antigen in serum. Only 36% of the patients with OI presented the combination of CD4 cells less than 0.200 x 10(9)/l and p24 in serum...

  17. Serum Sodium and Potassium Levels in Cerebro-vascular Accident Patients.

    Science.gov (United States)

    Farahmand, Farahmand; Choobi Anzali, Babak; Heshmat, Ramin; Ghafouri, Hamed-Basir; Hamedanchi, Sepehr

    2013-05-01

    We aim to assess serum sodium and potassium levels in patients with different types of cerebro-vascular accidents (CVA) in comparison to control group. A comparative cross-sectional study conducted on patients admitted to the emergency department from January to August 2012. Control group consisted of patients admitted to emergency department due to common cold, urinary tract infection, low back pain, cluster, and tension headache or migraine. Serum sodium and potassium levels were measured via standard laboratory methods. There were 77 patients in control group and 78 in CVA group. Forty nine patients from the CVA group had ischemic CVA, 11 had hemorrhagic CVA and 18 suffered a transient ischemic attack (TIA). Serum sodium level in control group was significantly lower than in patients with TIA, ischemic CVA, and hemorrhagic CVA (P < 0.001). Serum potassium level in control group was higher than patients with TIA, ischemic CVA, and hemorrhagic CVA (P < 0.001). Patients with hemorrhagic CVA showed significantly lower serum potassium level than patients with TIA and ischemic CVA (P < 0.001). Correspondingly, it was observed that serum sodium to potassium ratio was higher in patients with TIA, ischemic CVA, and hemorrhagic CVA (P < 0.001). In patients with hemorrhagic CVA serum sodium to potassium ratio was higher when compared to patients with TIA and ischemic CVA (P < 0.001). This study shows that higher serum sodium and lower serum potassium level may be associated with higher incidence of CVA. Further studies are paramount to elucidate the role of serum electrolyte levels in vascular events.

  18. Comparison of starch and gelatin hydrogels for non-toxic supercapacitor electrolytes

    Science.gov (United States)

    Railanmaa, Anna; Lehtimäki, Suvi; Lupo, Donald

    2017-06-01

    Starch and gelatin are two of the most abundantly available natural polymers. Their non-toxicity, low cost, and compatibility with aqueous solvents make them ideal for use in ubiquitous, environmentally friendly electronics systems. This work presents the results of conductivity measurements through impedance spectroscopy for gelatin- and starch-based aqueous gel electrolytes. The NaCl-based gels were physically cross-linked. The conductivity values were 84.6 mS/cm at 1.5 mol L-1 and 71.5 mS/cm at 2 mol L-1 for gelatin and starch, respectively. The mechanical properties of gelatin were found preferable to those of starch, although they deteriorated significantly when the salt concentration exceeded 2 mol L-1. The ability of the gels to successfully act as a supercapacitor electrolyte was demonstrated with printed electrodes on plastic substrate. The devices were characterized through cyclic voltammetry measurements. The results imply that these polymer gel electrolytes are very promising for replacing the traditional aqueous liquid electrolytes in supercapacitors in applications where, for example, user and environmental safety is essential.

  19. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  20. Serum protein electrophoresis values for free-ranging and zoo-based koalas (Phascolarctos cinereus).

    Science.gov (United States)

    Pye, Geoffrey W; Ellis, William; Fitzgibbon, Sean; Opitz, Brian; Keener, Laura; Arheart, Kristopher L; Cray, Carolyn

    2012-03-01

    In a clinical setting, especially with species of special interest, it is important to use all clinical pathology testing options for general health monitoring and diagnosis. Protein electrophoresis (EPH) has previously been shown to be an important adjunct tool in veterinary medicine. Serum samples from 18 free-ranging and 12 zoo-based koalas (Phascolarctos cinereus) were subject to EPH analysis. Significant differences were found between the two groups for the following values: total protein, albumin, beta globulins, and albumin-globulin ratio (P < 0.05). By using the combined data, the minimum-maximum values for the EPH fractions were as follows: total protein 5.0-7.8 g/dl, albumin 2.8-4.7 g/dl, alpha-1 globulins 0.5-1.1 g/dl, alpha-2 globulins 0.3-0.7 g/dl, beta globulins 0.4-1.0 g/dl, gamma globulins 0.2-1.0 g/dl, and albumin-globulin ratio 1.0-2.1.

  1. Reference values for serum ferritin and percentage of transferrin saturation in Korean children and adolescents.

    Science.gov (United States)

    Oh, Hea Lin; Lee, Jun Ah; Kim, Dong Ho; Lim, Jung Sub

    2018-03-01

    Ferritin reference values vary by age, gender, and ethnicity. We aimed to determine reference values of serum ferritin (SF) and the percentage of transferrin saturation (TSAT) for Korean children and adolescents. We analyzed data from 2,487 participants (1,311 males and 1,176 females) aged 10-20 years from the Korea National Health and Nutrition Examination Survey (2010-2012). We calculated age- and gender-stratified means and percentile values for SF and TSAT. We first plotted mean SF and TSAT by gender and according to age. In males, mean SF tended to be relatively constant among participants aged 10 to 14 years, with an upward trend thereafter. Mean SF trended downward among female participants until the age of 15 years and remained constant thereafter. Thus, significant gender differences in ferritin exist from the age of 14 years. High levels of SF were associated with obesity, and lower SF levels were associated with anemia and menarche status. We established reference values of SF and TSAT according to age and gender. The reference values for SF calculated in this study can be used to test the association between SF values and other defined diseases in Korean children and adolescents.

  2. Formation of Reversible Solid Electrolyte Interface on Graphite Surface from Concentrated Electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Dongping; Tao, Jinhui; Yan, Pengfei; Henderson, Wesley A.; Li, Qiuyan; Shao, Yuyan; Helm, Monte L.; Borodin, Oleg; Graff, Gordon L.; Polzin, Bryant; Wang, Chong-Min; Engelhard, Mark; Zhang, Ji-Guang; De Yoreo, James J.; Liu, Jun; Xiao, Jie

    2017-02-10

    Interfacial phenomena have always been key determinants for the performance of energy storage technologies. The solid electrolyte interfacial (SEI) layer, pervasive on the surfaces of battery electrodes for numerous chemical couples, directly affects the ion transport, charge transfer and lifespan of the entire energy system. Almost all SEI layers, however, are unstable resulting in the continuous consumption of the electrolyte. Typically, this leads to the accumulation of degradation products on/restructuring of the electrode surface and thus increased cell impedance, which largely limits the long-term operation of the electrochemical reactions. Herein, a completely new SEI formation mechanism has been discovered, in which the electrolyte components reversibly self-assemble into a protective surface coating on a graphite electrode upon changing the potential. In contrast to the established wisdom regarding the necessity of employing the solvent ethylene carbonate (EC) to form a protective SEI layer on graphite, a wide range of EC-free electrolytes are demonstrated for the reversible intercalation/deintercalation of Li+ cations within a graphite lattice, thereby providing tremendous flexibility in electrolyte tailoring for battery couples. This novel finding is broadly applicable and provides guidance for how to control interfacial reactions through the relationship between ion aggregation and solvent decomposition at polarized interfaces.

  3. Organic-inorganic hybrid polymer electrolytes based on polyether diamine, alkoxysilane, and trichlorotriazine: Synthesis, characterization, and electrochemical applications

    Science.gov (United States)

    Saikia, Diganta; Wu, Cheng-Gang; Fang, Jason; Tsai, Li-Duan; Kao, Hsien-Ming

    2014-12-01

    A new type of highly conductive organic-inorganic hybrid polymer electrolytes has been synthesized by the reaction of poly(propylene glycol)-block-poly(ethylene glycol)-block-poly(propylene glycol) bis(2-aminopropyl ether), 2,4,6-trichloro-1,3,5-triazine and alkoxysilane precursor 3-(glycidyloxypropyl)trimethoxysilane, followed by doping of LiClO4. The 13C and 29Si solid-sate NMR results confirm the successful synthesis of the organic-inorganic hybrid structure. The solid hybrid electrolyte thus obtained exhibits a maximum ionic conductivity of 1.6 × 10-4 S cm-1 at 30 °C, which is the highest among the organic-inorganic hybrid electrolytes. The hybrid electrolytes are electrochemically stable up to 4.2 V. The prototype electrochromic device with such a solid hybrid electrolyte demonstrates a good coloration efficiency value of 183 cm2 C-1 with a cycle life over 200 cycles. For the lithium-ion battery test, the salt free solid hybrid membrane is swelled with a LiPF6-containing electrolyte solution to reach an acceptable ionic conductivity value of 6.5 × 10-3 S cm-1 at 30 °C. The battery cell carries an initial discharge capacity of 100 mAh g-1 at 0.2C-rate and a coulombic efficiency of about 95% up to 30 cycles without the sign of cell failure. The present organic-inorganic hybrid electrolytes hold promise for applications in electrochromic devices and lithium ion batteries.

  4. Diagnostic value of combined determination of serum CA19-9 and TGF-β contents in patients with pancreatic cancer

    International Nuclear Information System (INIS)

    Gong Zheng

    2008-01-01

    Objective: To study the clinical diagnostic value of combined determination of serum contents of CA19-9 and TGF-β in patients with pancreatic cancer. Methods: Serum CA19-9 (with RIA) and TGF-β (with ELISA) contents were deter- mined in 30 patients with pancreatic cancer and 35 controls. Results: The serum CA19-9 and TGF-β contents in patients with pancreatic cancer were significantly higher than those in controls (P<0.01). The diagnostic sensitivity of CA19-9 for pancreatic cancer was 70.8%, lower than that of TGF-β (80.2%, P<0.05). The diagnostic specificity of CA19-9 and TGF-β was 90.2% and 93.4% respectively. Conclusion: Both determinations of serum CA19-9 and TGF-β contents would yield high specificity for diagnosis of pancreatic cancer. Sensitity of TGF-β determination was higher than that of CA19-9 determination. Combined determination of CA19-9 and TGF-β would improve the diagnostic accuracy in patients with pancreatic cancer. (authors)

  5. Arterial blood pressure but not serum albumin concentration correlates with ADC ratio values in pediatric posterior reversible encephalopathy syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Furtado, Andre; Zuccoli, Giulio [Section of Neuroradiology Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States); Hsu, Ariel [University of Pittsburgh Medical Center, Department of Radiology, Pittsburgh, PA (United States); La Colla, Luca [University of Parma, Department of Anesthesiology, Parma (Italy)

    2015-07-15

    Posterior reversible encephalopathy syndrome (PRES) is a clinical-radiological entity affecting both adults and children characterized by neurotoxicity often in setting of hypertension coupled with distinct brain magnetic resonance imaging features. Decreased serum albumin level has been suggested to correlate with the presence of vasogenic brain edema in adult PRES. Serum albumin has thus been hypothesized to protect against neurotoxicity in PRES by reducing vasogenic brain edema through its role in maintaining plasma osmotic pressure and endothelial integrity. The purpose of our study was to investigate if such correlation between decreased serum albumin level and PRES-related vasogenic edema could be found in children. We conducted a retrospective study of 25 pediatric patients diagnosed with PRES. Underlying clinical conditions, presenting symptoms, blood pressures, and serum albumin levels at onset of symptoms were collected. Brain MR imaging studies were reviewed. We used a quantitative method to evaluate the degree of vasogenic edema by measuring apparent diffusion coefficient (ADC) values of the T2-FLAIR hyperintense brain lesions. No significant correlation was found between serum albumin level and degree of PRES-related vasogenic edema. A significant correlation was found between elevated blood pressure and degree of vasogenic edema in the temporal lobes (p = 0.02 and 0.04, respectively) but not in the other cerebral lobes or cerebellum. Our initial results suggest blood pressure, not serum albumin level, as a main biomarker for brain edema in children with PRES. Thus, our study does not suggest a protective role of serum albumin against PRES-related neurotoxicity in children. (orig.)

  6. Solid-state supercapacitors with ionic liquid based gel polymer electrolyte: Effect of lithium salt addition

    Science.gov (United States)

    Pandey, G. P.; Hashmi, S. A.

    2013-12-01

    Performance characteristics of the solid-state supercapacitors fabricated with ionic liquid (IL) incorporated gel polymer electrolyte and acid treated multiwalled carbon nanotube (MWCNT) electrodes have been studied. The effect of Li-salt (LiPF6) addition in the IL (1-ethyl-3-methylimidazolium tris(pentafluoroethyl) trifluorophosphate, EMImFAP) based gel electrolyte on the performance of supercapacitors has been specifically investigated. The LiPF6/IL/poly(vinylidine fluoride-co-hexafluoropropylene) (PVdF-HFP) gel electrolyte film possesses excellent electrochemical window of 4 V (from -2.0 to 2.0 V), high ionic conductivity ∼2.6 × 10-3 S cm-1 at 20 °C and high enough thermal stability. The comparative performance of supercapacitors employing electrolytes with and without lithium salt has been evaluated by impedance spectroscopy and cyclic voltammetric studies. The acid-treated MWCNT electrodes show specific capacitance of ∼127 F g-1 with IL/LiPF6 containing gel polymer electrolyte as compared to that with the gel polymer electrolyte without Li-salt, showing the value of ∼76 F g-1. The long cycling stability of the solid state supercapacitor based on the Li-salt containing gel polymer electrolyte confirms the electrochemical stability of the electrolyte.

  7. New polysaccharide-based polymer electrolytes; Nouveaux electrolytes polymeres a base de polysaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Velasquez-Morales, P.; Le Nest, J.F.; Gandini, A. [Ecole Francaise de Papeterie et des Industries Graphique, 38 - Saint Martin d`Heres (France)

    1996-12-31

    Polysaccharides like cellulose and chitosan are known for their filmic properties. This paper concerns the synthesis and the study of chitosan-based polymer electrolytes. A preliminary work concerns the study of glucosamine reactivity. The poly-condensation of chitosan ethers (obtained by reaction with ethylene oxide or propylene oxide) with bifunctional and monofunctional oligo-ethers leads to the formation of thin lattices (10 {mu}m) having excellent mechanical properties. The presence of grafted polyether chains along the polysaccharide skeleton allows to modify the vitreous transition temperature and the molecular disorder of the system. Two type of polymer electrolytes have been synthesized: electrolytes carrying a dissolved alkaline metal salt and ionomers. The analysis of their thermal, dynamical mechanical, nuclear magnetic relaxation, electrical, and electrochemical properties shows that this new class of polymer electrolytes has the same performances as ethylene poly-oxide based amorphous lattices plus the advantage of having good filmic properties. Abstract only. (J.S.)

  8. New polysaccharide-based polymer electrolytes; Nouveaux electrolytes polymeres a base de polysaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Velasquez-Morales, P; Le Nest, J F; Gandini, A [Ecole Francaise de Papeterie et des Industries Graphique, 38 - Saint Martin d` Heres (France)

    1997-12-31

    Polysaccharides like cellulose and chitosan are known for their filmic properties. This paper concerns the synthesis and the study of chitosan-based polymer electrolytes. A preliminary work concerns the study of glucosamine reactivity. The poly-condensation of chitosan ethers (obtained by reaction with ethylene oxide or propylene oxide) with bifunctional and monofunctional oligo-ethers leads to the formation of thin lattices (10 {mu}m) having excellent mechanical properties. The presence of grafted polyether chains along the polysaccharide skeleton allows to modify the vitreous transition temperature and the molecular disorder of the system. Two type of polymer electrolytes have been synthesized: electrolytes carrying a dissolved alkaline metal salt and ionomers. The analysis of their thermal, dynamical mechanical, nuclear magnetic relaxation, electrical, and electrochemical properties shows that this new class of polymer electrolytes has the same performances as ethylene poly-oxide based amorphous lattices plus the advantage of having good filmic properties. Abstract only. (J.S.)

  9. Study of Serum Amylase and Serum Cholinesterase in Organophosphorus Poisoning

    Directory of Open Access Journals (Sweden)

    Sharan Badiger

    2016-04-01

    Full Text Available Background: Poisoning due to organophosphorus compounds is most commonly seen. Earlier plasma cholinesterase level was used to assess the severity of poisoning. Presently serum amylase is being recommended as a better indicator of severity. Aims and Objectives: To study plasma cholinesterase and serum amylase levels in acute organophosphorus and to correlate serum amylase levels with clinical severity and outcome. Material and Methods: A total of 80 patients in the study admitted to a tertiary care centre within 24 hours with a history of organophosphorus poisoning were included in study. Estimation of plasma cholinesterase and serum rd amylase was done at the time of admission, and on 3 th day and on 5 day. Results: Occurrence of organophosphorus poisoning was more common among age group 21-30 years and among males (57.5%. They were 25 (31.2% farmers, 23 (28.8% st u d e n ts, a n d 2 2 ( 2 7 . 5% h o u s ewi v e s. Monocrotophos (45.0% was commonly used compound. Mean value of plasma cholinesterase and serum amylase at admission are 3693 U/L, and 185.4 U/L. There was significant inhibition of plasma cholinesterase and elevation of serum amylase at th admission with return to normal values on 5 day. Conclusion: Plasma cholinesterase inhibition 200 U/L has been associated with poor prognosis and proneness to respiratory failure.

  10. Diagnostic value of combined determination of serum tumor markers (NSE, CA-242, TPA, CEA) levels in patients with lung cancer

    International Nuclear Information System (INIS)

    Liu Juzhen; Cai Tietie; Qin Shana

    2007-01-01

    Objective: To investigate the diagnostic value of combined determination of serum NSE, CA242, tissue polypeptide antigen (TPA) and CEA levels in patients with primary lung cancer. Methods: Serum NSE, CA242, TPA and CEA levels were determined with ELISA in (1) 102 patients with various types of primary lung carcinoma (adenocarcinoma 38, squamous cell carcinoma 32, small cell lung carcinoma 32) (2) 33 patients with open lung T. B. and (3) 30 controls. Results: (1) In patients with lung cancer, serum levels of all the four markers were increased and significantly higher than their respective values in patients with open lung T.B. and controls. (2) Positive rate of combined any two markers were 75% for adenocarcinoma, 50% for squamous cell carcinoma and 65% for small cell lung carcinoma, while false positive rate was only 9% for T.B patients and none for the controls. (3) The most appropriate single marker for each specific type of lung cancer was: NSE for SCLC (sensitivity 72%, specificity 97%, CA242 for adenocarcinoma sensitivity 62%, specificity 90%). Conclusion: Combined determination of these tumor markers would improve the sensitivity and specificity for diagnosis of primary lung carcinoma. (authors)

  11. Assessment of the diagnostic value of combined determination of serum CA199 CA125 and CEA in patients with cancer of pancreas

    International Nuclear Information System (INIS)

    Wu Congshan; Liu Xugui

    2005-01-01

    Objective: To assess the diagnostic value of combined determination of serum CA199, CA125 and CEA for cancer of pancreas. Methods: Serum CA199, CA125 and CEA levels were detected with CLIA in 32 patients with cancer of pancreas and 36 controls. Results: Positive detection rate of CA199 in patients with cancer of pancreas was 90.6% (29/32). Positive rate for CA125 and CEA was 65.6% (21/32) and 46.9% (15/32) respectively. With combined determination of these 3 tumor markers, the positive rate was 96.9% (31/32). The mean content of serum CA199 after successful operation (32.5±8.4U/ml) was significantly lower than that before operation (840.2 ± 102.5U/ml) (P<0.01). Conclusion: Combined determination of CA199, CA125 and CEA would improve the detection rate of cancer of pancreas and post-operative changes of CA199 could be of prognostic value. (authors)

  12. Polymer Electrolytes for Lithium/Sulfur Batteries

    Directory of Open Access Journals (Sweden)

    The Nam Long Doan

    2012-08-01

    Full Text Available This review evaluates the characteristics and advantages of employing polymer electrolytes in lithium/sulfur (Li/S batteries. The main highlights of this study constitute detailed information on the advanced developments for solid polymer electrolytes and gel polymer electrolytes, used in the lithium/sulfur battery. This includes an in-depth analysis conducted on the preparation and electrochemical characteristics of the Li/S batteries based on these polymer electrolytes.

  13. A general approach toward enhancement of pseudocapacitive performance of conducting polymers by redox-active electrolytes

    KAUST Repository

    Chen, Wei

    2014-12-01

    A general approach is demonstrated where the pseudocapacitive performance of different conducting polymers is enhanced in redox-active electrolytes. The concept is demonstrated using several electroactive conducting polymers, including polyaniline, polypyrrole, and poly(3,4-ethylenedioxythiophene). As compared to conventional electrolytes, the redox-active electrolytes, prepared by simply adding a redox mediator to the conventional electrolyte, can significantly improve the energy storage capacity of pseudocapacitors with different conducting polymers. The results show that the specific capacitance of conducting polymer based pseudocapacitors can be increased by a factor of two by utilization of the redox-active electrolytes. In fact, this approach gives some of the highest reported specific capacitance values for electroactive conducting polymers. Moreover, our findings present a general and effective approach for the enhancement of energy storage performance of pseudocapacitors using a variety of polymeric electrode materials. © 2014 Elsevier B.V. All rights reserved.

  14. Ultraviolet-absorbing organic anions in uremic serum separated by capillary zone electrophoresis, and quantification of hippuric acid

    NARCIS (Netherlands)

    Schoots, A.C.; Verheggen, T.P.E.M.; Vries, de P.M.J.M.; Everaerts, F.M.

    1990-01-01

    Organic anions accumulated in blood serum of patients with chronic renal failure were separated by a novel technique: closed-system capillary zone electrophoresis (CZE) in a pH6 carrier-electrolyte system. Hippuric acid (HA), p-hydroxyhippuric acid, and uric acid were identified by their co-elution

  15. Solid polymer electrolyte from phosphorylated chitosan

    Energy Technology Data Exchange (ETDEWEB)

    Fauzi, Iqbal, E-mail: arcana@chem.itb.ac.id; Arcana, I Made, E-mail: arcana@chem.itb.ac.id [Inorganic and Physical Chemistry Research Groups, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia)

    2014-03-24

    Recently, the need of secondary battery application continues to increase. The secondary battery which using a liquid electrolyte was indicated had some weakness. A solid polymer electrolyte is an alternative electrolytes membrane which developed in order to replace the liquid electrolyte type. In the present study, the effect of phosphorylation on to polymer electrolyte membrane which synthesized from chitosan and lithium perchlorate salts was investigated. The effect of the component’s composition respectively on the properties of polymer electrolyte, was carried out by analyzed of it’s characterization such as functional groups, ion conductivity, and thermal properties. The mechanical properties i.e tensile resistance and the morphology structure of membrane surface were determined. The phosphorylation processing of polymer electrolyte membrane of chitosan and lithium perchlorate was conducted by immersing with phosphoric acid for 2 hours, and then irradiated on a microwave for 60 seconds. The degree of deacetylation of chitosan derived from shrimp shells was obtained around 75.4%. Relative molecular mass of chitosan was obtained by viscometry method is 796,792 g/mol. The ionic conductivity of chitosan membrane was increase from 6.33 × 10{sup −6} S/cm up to 6.01 × 10{sup −4} S/cm after adding by 15 % solution of lithium perchlorate. After phosphorylation, the ionic conductivity of phosphorylated lithium chitosan membrane was observed 1.37 × 10{sup −3} S/cm, while the tensile resistance of 40.2 MPa with a better thermal resistance. On the strength of electrolyte membrane properties, this polymer electrolyte membrane was suggested had one potential used for polymer electrolyte in field of lithium battery applications.

  16. Composition of highly concentrated silicate electrolytes and ultrasound influencing the plasma electrolytic oxidation of magnesium

    Science.gov (United States)

    Simchen, F.; Rymer, L.-M.; Sieber, M.; Lampke, T.

    2017-03-01

    Magnesium and its alloys are increasingly in use as lightweight construction materials. However, their inappropriate corrosion and wear resistance often prevent their direct practical use. The plasma electrolytic oxidation (PEO) is a promising, environmentally friendly method to improve the surface characteristics of magnesium materials by the formation of oxide coatings. These PEO layers contain components of the applied electrolyte and can be shifted in their composition by increasing the concentration of the electrolyte constituents. Therefore, in contrast to the use of conventional low concentrated electrolytes, the process results in more stable protective coatings, in which electrolyte species are the dominating constitutes. In the present work, the influence of the composition of highly concentrated alkaline silicate electrolytes with additives of phosphate and glycerol on the quality of PEO layers on the magnesium alloy AZ31 was examined. The effect of ultrasound coupled into the electrolyte bath was also considered. The process was monitored by recording the electrical process variables with a transient recorder and by observation of the discharge phenomena on the sample surface with a camera. The study was conducted on the basis of a design of experiments. The effects of the process parameter variation are considered with regard to the coatings thickness, hardness and corrosion resistance. Information about the statistical significance of the effects of the parameters on the considered properties is obtained by an analysis of variance (ANOVA).

  17. Simulation of an electrolytic bath for electrodeposition of multilayer shielding coatings

    Directory of Open Access Journals (Sweden)

    E. A. Dolmatova

    2015-10-01

    Full Text Available In the work galvanic bath of Cu/(Ni+Cu multilayer shielding coatings formation from an acetate electrolyte containing 0,03 mol/L of CuAc2, 0,3 mol/L of NiAc2 and 1,66 mol/L of acetic acid. According to the results of polarization studies values of coatings deposition pulse mode current density have been chosen and current efficiency of copper and nickel during deposition of Cu-Ni alloy has been determined. To ensure a constant formulation of the electrolyte it has been proposed to use insoluble anodes made of stainless steel and continuous circulation of the electrolyte. The scheme of steams enabling the adjustment of the solution formulation with the use of an additional collecting vessel has been developed. The formulation of the correcting stream continuously fed into the collecting vessel has been calculated.

  18. Effect of a novel amphipathic ionic liquid on lithium deposition in gel polymer electrolytes

    International Nuclear Information System (INIS)

    Choi, Nam-Soon; Koo, Bonjae; Yeon, Jin-Tak; Lee, Kyu Tae; Kim, Dong-Won

    2011-01-01

    Highlights: · Synthesis of a dimeric ionic liquid. · Gel polymer electrolytes providing uniform lithium deposit pathway. · An amphipathic ionic liquid locates at the interface between an electrolyte-rich phase and a polymer matrix in a gel polymer electrolyte. · The presence of PDMITFSI ionic liquid leads to the suppression of dendritic lithium formation on a lithium metal electrode. - Abstract: A novel dimeric ionic liquid based on imidazolium cation and bis(trifluoromethanesulfonyl) imide (TFSI) anion has been synthesized through a metathesis reaction. Its chemical shift values and thermal properties are identified via 1 H nuclear magnetic resonance (NMR) imaging and differential scanning calorimetry (DSC). The effect of the synthesized dimeric ionic liquid on the interfacial resistance of gel polymer electrolytes is described. Differences in the SEM images of lithium electrodes after lithium deposition with and without the 1,1'-pentyl-bis(2,3-dimethylimidazolium) bis(trifluoromethane-sulfonyl)imide (PDMITFSI) ionic liquid in gel polymer electrolytes are clearly discernible. This occurs because the PDMITFSI ionic liquid with hydrophobic moieties and polar groups modulates lithium deposit pathways onto the lithium metal anode. Moreover, high anodic stability for a gel polymer electrolyte with the PDMITFSI ionic liquid was clearly observed.

  19. Monoclonal protein reference change value as determined by gel-based serum protein electrophoresis.

    Science.gov (United States)

    Salamatmanesh, Mina; McCudden, Christopher R; McCurdy, Arleigh; Booth, Ronald A

    2018-01-01

    The International Myeloma Working Group recommendations for monitoring disease progression or response include quantitation of the involved monoclonal immunoglobulin. They have defined the minimum change criteria of ≧25% with an absolute change of no gel-based serum protein electrophoresis. Sixteen clinically stable MGUS patients were identified from our clinical hematology database. Individual biological variability (CVi) was determined and used to calculate a monoclonal protein reference change value (RCV). Analytical variability of the normal protein fractions (albumin, alpha-1, alpha-2, beta, total gamma) ranged from 1.3% for albumin to 5.8% for the alpha-1 globulins. CVa of low (5.6g/L) and high (32.2g/L) concentration monoclonal proteins were 3.1% and 22.2%, respectively. Individual CVi of stable patients ranged from 3.5% to 24.5% with a CVi of 12.9%. The reference change value (RCV) at a 95% probability was determined to be 36.7% (low) 39.6% (high) using our CVa and CVi. Serial monitoring of monoclonal protein concentration is important for MGUS and multiple myeloma patients. Accurate criteria for interpreting a change in monoclonal protein concentration are required for appropriate decision making. We used QC results and real-world conditions to assess imprecision of serum protein fractions including low and high monoclonal protein fractions and clinically stable MGUS patients to determine CVi and RCV. The calculated RCVs of 36.7% (low) and 39.6% (high) in this study were greater that reported previously and greater than the established criteria for relapse. Response criteria may be reassessed to increase sensitivity and specificity for detection of response. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Effect of strong electrolytes on edible oils part III: viscosity of canola ...

    African Journals Online (AJOL)

    ... in the positive values of B-coefficient. Fluidity parameters were also evaluated and the change in these values with temperature and concentration of oil shows that the electrolytes behave as structure breaker. The energy of activation, latent heat of vaporization and molar volume of oil were also evaluated and discussed.

  1. Clinical value of combined determination of serum and hydrothorax fluid levels of CEA, CA125, NSE in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Su Wentang; Shu Lingling; Yang Huaxi

    2007-01-01

    Objective: To study the clinical value of combined determination of CEA, CA125, NSE levels both in serum and hydrothorax fluid in the diagnosis of lung cancer. Methods: Serum and hydrothorax fluid levels of CEA, CA125, NSE were determined with RIA in 88 patients with lung cancers, 100 patients with inflammatory hydrothorax, and 50 controls. Results: The levels of serum and hydrothorax fluid CEA, CA125, NSE in lung cancer patients were significantly higher than those in patients with inflammatory hydrothorax and controls (P <0.05). In lung cancer group, the positive rate of combined detection of serum CEA, CA125, NSE was 70.5%, the positive rate of combined detection of hydrothorax fluid CEA, CA125, NSE was 79.5% and the positive rate of combined detection of serum and hydrothorax fluid three kinds of tumor markers was 87. 5%. Conclusion: Combined detection of serum and hydrothuax fluid levels of CEA, CA125, NSE is to be advocated because of higher sensitivity for diagnosis of lung cancer. (authors)

  2. Predictive value of serum sST2 in preschool wheezers for development of asthma with high FeNO.

    Science.gov (United States)

    Ketelaar, M E; van de Kant, K D; Dijk, F N; Klaassen, E M; Grotenboer, N S; Nawijn, M C; Dompeling, E; Koppelman, G H

    2017-11-01

    Wheezing is common in childhood. However, current prediction models of pediatric asthma have only modest accuracy. Novel biomarkers and definition of subphenotypes may improve asthma prediction. Interleukin-1-receptor-like-1 (IL1RL1 or ST2) is a well-replicated asthma gene and associates with eosinophilia. We investigated whether serum sST2 predicts asthma and asthma with elevated exhaled NO (FeNO), compared to the commonly used Asthma Prediction Index (API). Using logistic regression modeling, we found that serum sST2 levels in 2-3 years-old wheezers do not predict doctors' diagnosed asthma at age 6 years. Instead, sST2 predicts a subphenotype of asthma characterized by increased levels of FeNO, a marker for eosinophilic airway inflammation. Herein, sST2 improved the predictive value of the API (AUC=0.70, 95% CI 0.56-0.84), but had also significant predictive value on its own (AUC=0.65, 95% CI 0.52-0.79). Our study indicates that sST2 in preschool wheezers has predictive value for the development of eosinophilic airway inflammation in asthmatic children at school age. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  3. Structural and Electrochemical Analysis of PMMA Based Gel Electrolyte Membranes

    Directory of Open Access Journals (Sweden)

    Chithra M. Mathew

    2015-01-01

    Full Text Available New gel polymer electrolytes containing poly(vinylidene chloride-co-acrylonitrile and poly(methyl methacrylate are prepared by solution casting method. With the addition of 60 wt.% of EC to PVdC-AN/PMMA blend, ionic conductivity value 0.398×10-6 S cm−1 has been achieved. XRD and FT-IR studies have been conducted to investigate the structure and complexation in the polymer gel electrolytes. The FT-IR spectra show that the functional groups C=O and C≡N play major role in ion conduction. Thermal stability of the prepared membranes is found to be about 180°C.

  4. Mathematical modeling of the lithium, thionyl chloride static cell. I. Neutral electrolyte. II - Acid electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Tsaur, K.C.; Pollard, R.

    1984-05-01

    Mathematical models are presented for a Li-LiAlCl4/SOCl2-C static cell with neutral electrolyte and a Li/SOCl2-C static cell with acid electrolyte. The model for the Li-LiAlCl4/SOCl2-C cell with neutral solution predicts that high internal resistance can develop in the positive electrode as a result of low local porosities which are, in turn, caused by large-volume, solid reaction products. Consequently, the maximum usable cell capacity is dictated by the nonuniformity of the reaction distribution at the front of the positive electrode. In many respects, a cell with acid electrolyte can be regarded as a combination of an equivalent neutral electrolyte system and an acid reservoir. The model for the Li/SOCl2 cell suggests that the cell life depends primarily on the quantity of acid added to the electrolyte. 58 references.

  5. Mathematical modeling of the lithium, thionyl chloride static cell. I - Neutral electrolyte. II - Acid electrolyte

    Science.gov (United States)

    Tsaur, K.-C.; Pollard, R.

    1984-05-01

    Mathematical models are presented for a Li-LiAlCl4/SOCl2-C static cell with neutral electrolyte and a Li/SOCl2-C static cell with acid electrolyte. The model for the Li-LiAlCl4/SOCl2-C cell with neutral solution predicts that high internal resistance can develop in the positive electrode as a result of low local porosities which are, in turn, caused by large-volume, solid reaction products. Consequently, the maximum usable cell capacity is dictated by the nonuniformity of the reaction distribution at the front of the positive electrode. In many respects, a cell with acid electrolyte can be regarded as a combination of an equivalent neutral electrolyte system and an acid reservoir. The model for the Li/SOCl2 cell suggests that the cell life depends primarily on the quantity of acid added to the electrolyte.

  6. BFR Electrolyte Additive Safety and Flammability Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Allcorn, Eric [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-13

    Lithium-ion battery safety is a critical issue in the adoption of the chemistry to larger scale applications such as transportation and stationary storage. One of the critical components impacting the safety of lithium-ion batteries is their use of highly flammable organic electrolytes. In this work, brominated flame retardants (BFR’s) – an existing class of flame retardant materials – are incorporated as additives to lithium-ion battery electrolytes with the intention to reduce the electrolyte flammability and thereby improve safety. There are a few critical needs for a successful electrolyte additive: solubility in the electrolyte, electrochemical stability over the range of battery operation, and minimal detrimental effects on battery performance. Those detrimental effects can take the form of electrolyte specific impacts, such as a reduction in conductivity, or electrode impacts, such as SEI-layer modification or chemical instability to the active material. In addition to these needs, the electrolyte additive also needs to achieve its intended purpose, which in this case is to reduce the flammability of the electrolyte. For the work conducted as part of this SPP agreement three separate BFR materials were provided by Albemarle to be tested by Sandia as additives in a traditional lithium-ion battery electrolyte. The provided BFR materials were tribromo-neopentyl alcohol, tetrabromo bisphenol A, and tribromoethylene. These materials were incorporated as separate 4 wt.% additives into a traditional lithium-ion battery electrolyte and compared to said traditional electrolyte, designated Gen2.

  7. Effects of Hypertonic Saline Solution on Clinical Parameters, Serum Electrolytes and Plasma Volume in the Treatment of Haemorrhagic Septicaemia in Buffaloes

    Directory of Open Access Journals (Sweden)

    M. Arif Zafar*, G. Muhammad, Zafar Iqbal1 and M. Riaz2

    2010-04-01

    Full Text Available This study was conducted to determine the efficacy of hypertonic saline solution (HSS along with antibiotic (ceftiofur HCl and non-steroidal anti-inflammatory drug (ketoprofen in the treatment of haemorrhagic septicaemia in buffaloes. For this purpose, 50 buffaloes suffering from haemorrhagic septicaemia were randomly divided in two equal groups A and B. Group A served as control and was treated with ceftiofur HCl (IM and ketoprofen (IV @ 6 and 2 mg/Kg BW, respectively, for five days. Buffaloes of group B were administered with rapid intravenous infusion of hypertonic saline solution (7.5% NaCl @ 4 ml/Kg BW once in combination with ceftiofur HCl and ketoprofen. Animals were monitored for 24 hours after initiation of treatment. Clinical parameters, serum electrolytes, plasma volume and survival index were recorded at different intervals after treatment. Survival rate (80% in group B was significantly higher (P<0.05 than 48% in group A. The heart rate and respiration rate recovered more effectively in the buffaloes administered with treatment protocol B. Plasma volume was 98% which was almost normal within 24 hours after the infusion of hypertonic saline solution to the animals of group B. It was concluded from the study that hypertonic saline solution as an adjunct to antibiotic and a non-steroidal anti-inflammatory drug more efficiently improved respiration and heart rates and effectively restored plasma volume in resuscitating the buffaloes from haemorrhagic septicaemia than the conventional treatment.

  8. Multivalent weak electrolytes - risky background electrolytes for capillary zone electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Beckers, J. L.; Boček, Petr

    2002-01-01

    Roč. 23, č. 12 (2002), s. 1942-1946 ISSN 0173-0835 R&D Projects: GA ČR GA203/99/0044; GA ČR GA203/02/0023; GA ČR GA203/01/0401; GA AV ČR IAA4031703; GA AV ČR IAA4031103 Institutional research plan: CEZ:AV0Z4031919 Keywords : background electrolytes * capillary zone electrophoresis * multivalent electrolytes Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.325, year: 2002

  9. Electrolyte loss mechanism of molten carbonate fuel cells. 2.; Application to the cell with matrix electrolyte layer; Yoyu tansan`engata nenryo denchi ni okeru denkaishitsu loss kiko ni tsuite. 2.; Matrix gata denkaishitsuso wo yusuru denchi eno oyo

    Energy Technology Data Exchange (ETDEWEB)

    Sonai, A; Murata, K [Toshiba Research and Development Center, Kawasaki (Japan)

    1993-11-01

    A single cell of molten carbonate fuel cell using a matrix electrolyte layer fabricated by using the doctor blade process has been operated for several thousand hours, measured of electrolyte loss amount, and analyzed by using a new electrolyte loss mechanism. The result may be summarized as follows: according to a result of measuring the matrix layer pore distribution, the average pore size has increased little by little; pores with diameters greater than 2 {mu}m at which no electrolyte retention becomes possible remain at nearly constant ratio up to 1800 hours, but increased after 2500 hours; the pore capacity in ports with the largest electrolyte retaining diameter of 2 {mu}m or less showed slight decrease with time in the anode, and an initial decrease followed by flatness, and then a sharp decrease after 1800 hours in the matrix layer; the electrolyte loss measurement values have remained nearly constant for 25 hours to 1800 hours, but increased sharply thereafter; and the electrolyte loss in this single cell due to pore capacity decrease in pores as power generating parts with diameters smaller than 2 {mu}m was explained quantitatively by a new electrolyte loss mechanism. 11 refs., 6 figs.

  10. Ceramic membrane fuel cells based on solid proton electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Guangyao; Ma, Qianli; Peng, Ranran; Liu, Xingqin [USTC Lab. for Solid State Chemistry and Inorganic Membranes, Department of Materials Science and Engineering, University of Science and Technology of China, Hefei 230026 (China); Ma, Guilin [School of Chemistry and Chemical Engineering, Suzhou University, Suzhou 215123 (China)

    2007-04-15

    The development of solid oxide fuel cells (SOFCs) has reached its new stage characterized with thin electrolytes on porous electrode support, and the most important fabrication techniques developed in which almost all are concerned with inorganic membranes, and so can be named as ceramic membrane fuel cells (CMFCs). CMFCs based on proton electrolytes (CMFC-H) may exhibit more advantages than CMFCs based on oxygen-ion electrolytes (CMFC-O) in many respects, such as energy efficiency and avoiding carbon deposit. Ammonia fuelled CMFC with proton-conducting BaCe{sub 0.8}Gd{sub 0.2}O{sub 2.9} (BCGO) electrolyte (50 {mu}m in thickness) is reported in this works, which showed the open current voltage (OCV) values close to theoretical ones and rather high power density. And also, we have found that the well known super oxide ion conductor, La{sub 0.9}Sr{sub 0.1}Ga{sub 0.8}Mg{sub 0.2}O{sub 3-{alpha}} (LSGM), is a pure proton conductor in H{sub 2} and mixed proton and oxide ion conductor in wet air, while it is a pure oxide ion conductor in oxygen or dry air. To demonstrate the CMFC-H concept to get high performance fuel cells the techniques for thin membranes, chemical vapor deposition (CVD), particularly novel CVD techniques, should be given more attention because of their many advantages. (author)

  11. Fluid, electrolyte, and acid-base balances in three-day, combined-training horses.

    Science.gov (United States)

    White, S L

    1998-04-01

    Horses competing in 3-day, combined-training events develop a metabolic acidosis that is partially compensated for by a respiratory alkalosis immediately after phases B and D. By the end of phase C and 30 minutes to 2 hours after phase D, the acidosis is resolved by the oxidation of lactate, and a metabolic alkalosis prevails. A reduction in TBW and cation content occurs, which often is not replenished 12 to 24 hours after the event, even though the serum or plasma concentration of various constituents may be within normal limits. Hypochloremia and hypocalcemia, however, may persist 12 or more hours after the speed and endurance test. All of the data cited in this article are from horses that successfully completed their respective tests. Nevertheless, some horses developed substantial fluid and cation losses. In horses that are not well conditioned or in competitions in which terrain, footing, or hot environments increase the thermal load or decrease heat loss, greater losses of fluids and electrolytes can be expected. Body weight losses exceeding 5% and cation losses exceeding 4000 mEq/L occur in endurance horses suffering from exhaustion and synchronous diaphragmatic flutter. In one study, two thirds of the Na+ lost during exercise-induced sweating in cool, dry conditions was replenished from salt supplements added to a balanced forage and concentrated diet. Consequently, horses in regular training and competition may benefit from salt supplementation. The composition of the salt supplement and the amount fed should be based on the composition of the horse's diet, degree of work, and environmental conditions. Horses competing in a 3-day, combined-training event may be expected to have persistent losses of weight and cations, particularly if conditions result in heavy sweating. Many horses in the field studies had minimal changes in weight and cation balance compared with pre-event values. The diet and electrolyte supplementation of the horses in the majority of

  12. Study on the diagnostic value of determination of changes of serum CA125 and CA19-9 levels in patients with endometriosis

    International Nuclear Information System (INIS)

    Liu Aimin

    2008-01-01

    Objective: To explore the diagnostic value of determination of changes of serum CA125 and CA19-9 levels in patients with endometriosis. Methods: Serum CA125 and CA19-9 levels were determined with RIA in 45 patients with endometriosis and 40 controls. Results: Serum levels of CA125 and CA19-9 in patients with endometriosis (89.63 ± 30.16u/ml and 95.62±43.67u/ml respectively) were significantly higher than those (16.26±6.37u/ml and 20.26±8.25u/ml respectively) in controls (P<0. 001). Sensitivity of CA125 for diagnosis of endometriosis was 77.78% and that of CA19-9 was 62.22%, while the specificity was 92.50% and 90.00% respectively. If we only took the patients with both markers elevated as being diagnostically positive, the sensitivity would naturally be lower (57.78%) but the specificity would be 100%. Levels of the markers were significantly higher in stage III, IV patients than those in patients with stage I, II disease (P<0.01). Conclusion: Combined determination of serum CA125 and CA19-9 levels were of highly specific diagnostic value in patients with endometriosis. (authors)

  13. Application value of Serum Hs-CRP, IL-6 and plasma FIB joint detection in COPD

    Directory of Open Access Journals (Sweden)

    Feng Ji

    2016-11-01

    Full Text Available Objective: To discuss the application value of High sensitivity C-reactive protein (Hs-CRP, interleukin-6 (IL-6 and fibrinogen (FIB joint detection in chronic obstructive pulmonary disease (COPD. Methods: A total of 181 COPD cases were divided to be COPD stable phase group (65 cases and COPD acute exacerbation phase group (116 cases per the course of disease. COPD acute exacerbation phase group was classified into grade I (39 cases, grade II (43 cases and grade III (34 cases based on pulmonary function. Then survival group (87 cases and death group (29 cases were divided based on illness transition. Meanwhile, 80 cases of healthy people at the same phase were set to be healthy group. Differences in levels of Serum hs-CRP, IL-6 and FIB in these groups were analyzed, and according to these indexes, prognostic potency of COPD acute exacerbation phase could be evaluated. Results: Difference in serum hs-CRP, IL-6 and FIB levels in COPD stable phase group, COPD acute exacerbation phase group and healthy group were statistical significant (P<0.05. both for healthy group serum hs-CRP, IL-6 and FIB levels in grade I, II, III of pulmonary function in the COPD acute exacerbation phase group were statistical significant (P<0.05 both for grade 1 < grade 2 < grade 3. Result of person analyzing showed significant positive correlation on grading of pulmonary function and serum hs-CRP, IL-6 and FIB levels, the correlation coefficient was 0.573. Differences of hs-CRP, IL-6 and FIB levels between survival group and death group were statistical significant. Serum hs-CRP, IL-6 and FIB levels were utilized respectively to evaluate area under curve of receiver operating characteristic in prognostic COPD acute exacerbation phase group, namely, 0.836, 0.815, 0.776. Sensitivities of “death”, which was evaluated by the various indexes, respectively showed as: 72.41%, 65.51% and 75

  14. Clinical value of the joint measurement of serum concentrations of type IV collagen and laminin in patients with diabetic nephropathy

    International Nuclear Information System (INIS)

    Wang Lu; Wang Ping; Li Yongpei

    2004-01-01

    Objective: To study clinical value of the joint measurement of serum concentrations of type IV collagen (IV C) and laminin (LN) in patients with diabetic nephropathy (DN) by radioimmunoassay (RIA). Methods: Serum concentrations of IV C, LN were measured by RIA in 35 diabetic patients with normalbuminuria (group A), 28 cases of microalbuminuria (group B), 15 cases of macroalbuminuria (group C) and 30 normal subjects as control . Results: The serum concentrations of IV C, LN in total 78 diabetic patients [(97.6 ± 19.2), (132.4 ± 31.5) μg/L] were higher than that of the controls [(77.4 ± 8.2), (101.5 ± 17.6) μg/L, P<0.05], especially in group B and C, it was remarkably higher compared with the controls (P<0.05, P<0.01). There was significant positive correlation of serum IV C, LN to diabetic duration and the levels of blood urea nitrogen (BUN), creatinine (Cr), urinary albumin excretion rate (UAER). Conclusions: The results suggest that the joint measurement of serum levels of IV C, LN and UAER in DN patients might better evaluate the development process of DN, and be of help for early diagnosis and treatment of DN. Serum levels of IV C, LN and UAER in DN patients may become the reliable clinical markers for assessing the severity and predicting the prognosis of DN

  15. Molecular motion in polymer electrolytes. An investigation of methods for improving the conductivity of solid polymer electrolytes

    International Nuclear Information System (INIS)

    Webster, Mark Ian

    2002-01-01

    Three methods were explored with a view to enhancing the ionic conductivity of polymer electrolytes; namely the addition of an inert, inorganic filler, the addition of a plasticizer and the incorporation of the electrolyte in the pores of silica matrices. There have been a number of reports, which suggest the addition of nanocrystalline oxides to polymer electrolytes increases the ionic conductivities by about a factor of two. In this thesis studies of the polymer electrolyte NaSCN.P(EO) 8 with added nanocrystalline alumina powder are reported which show no evidence of enhanced conductivity. The addition of a plasticizer to polymer electrolytes will increase the ionic conductivity. A detailed study was made of the polymer electrolytes LiT.P(EO) 10 and LiClO 4 .P(EO) 10 with added ethylene carbonate plasticizer. The conductivities showed an enhancement, however this disappeared on heating under vacuum. The present work suggests that the plasticised system is not thermodynamically stable and will limit the applications of the material. A series of samples were prepared from the polymer electrolyte LiT.P(EO) 8 and a range of porous silicas. The silicas were selected to give a wide range of pore size and included Zeolite Y, ZSM5, mesoporous silica and a range of porous glasses. This gave pore sizes from less than one nm to 50 nm. A variety of experiments, including X-ray diffraction, DSC and NMR, showed that the polymer electrolyte entered to pores of the silica. As a result the polymer was amorphous and the room temperature conductivity was enhanced. The high temperature conductivity was not increased above that for the pure electrolyte. The results suggest that this could be employed in applications, however would require higher conducting electrolytes to be of practical benefit. (author)

  16. Electrolytic method to make alkali alcoholates using ion conducting alkali electrolyte/separator

    Science.gov (United States)

    Joshi, Ashok V [Salt Lake City, UT; Balagopal, Shekar [Sandy, UT; Pendelton, Justin [Salt Lake City, UT

    2011-12-13

    Alkali alcoholates, also called alkali alkoxides, are produced from alkali metal salt solutions and alcohol using a three-compartment electrolytic cell. The electrolytic cell includes an anolyte compartment configured with an anode, a buffer compartment, and a catholyte compartment configured with a cathode. An alkali ion conducting solid electrolyte configured to selectively transport alkali ions is positioned between the anolyte compartment and the buffer compartment. An alkali ion permeable separator is positioned between the buffer compartment and the catholyte compartment. The catholyte solution may include an alkali alcoholate and alcohol. The anolyte solution may include at least one alkali salt. The buffer compartment solution may include a soluble alkali salt and an alkali alcoholate in alcohol.

  17. Human Water and Electrolyte Balance

    National Research Council Canada - National Science Library

    Montain, S. J; Cheuvront, S. N; Carter, R; Sawka, M. N

    2006-01-01

    .... Sweat losses, if not replaced, reduce body water volume and electrolyte content. Excessive body water or electrolyte losses can disrupt physiological homeostasis and threaten both health and performance...

  18. Diagnostic value of combined detection of serum tumor markers for lung cancer

    International Nuclear Information System (INIS)

    Li Yanping; Wang Qun; Zhao Zihong; Zhou Shan

    2013-01-01

    Objective: To investigate the diagnostic value of combined detection of serum tumor markers, including CEA, CA125, neuron-specific enolase (NSE) and cytokeratin fragment antigen 21-1 (CYFRA21-1) for lung cancer patients. Methods: The subjects involved 138 diagnosed lung cancer patients (82 males, 56 females, average age 58.6 years, from October 2010 to March 2012), 96 patients with benign lung diseases (56 males, 40 females, average age 51.3 years) and 45 healthy adults (30 males, 15 females, average age 43.9 years). The pathological types of lung cancer consisted of 66 squamous cell carcinoma (SCC), 52 adenocarcinoma and 20 small cell lung cancer (SCLC). The serum levels of CEA, CA125, NSE and CYFRA21-1 were measured with electrochemiluminescence immunoassay. The diagnostic efficacy for different pathological types was compared among each single tumor marker and combination of tumor markers. One-way analysis of variance q test were used for statistical analysis. Results: The serum levels of CEA, CA125, NSE and CYFRA21-1 in patients with lung cancer were higher than those in patients with benign lung diseases and in healthy subjects (CEA: (19.99±30.99), (10.78±19.77), (3.25±3.42) μg/L; CA125: (79.70±95.98), (44.96±44.97), (20.66±7.13) μg/L; NSE: (35.23±40.22), (15.31±8.42), (13.30±5.65) μg/L; CYFRA21-1: (18.07±43.71), (8.30±8.83), (3.13±1.60) μg/L; F=4.481, 5.436, 4.776, 6.002, all P<0.05). The highest level of CEA, NSE or CYFRA21-1 were found in adenocarcinoma (F=4.932, P<0.05), SCLC (F=5.119, P<0.05) or SCC (F=5.378, P<0.05), respectively. The highest sensitivity tumor markers for SCC, SCLC and adenocarcinoma were CYFRA21-1 (78.8%, 52/66), NSE (75.0%, 15/20) and CEA (57.7%, 30/52), respectively. In combined detection, the highest sensitivity combinations for SCC, SCLC and adenocarcinoma were CEA + CYFRA21-1 + NSE (89.4%, 59/66), CEA + CYFRA21-1 + NSE (80.0%, 16/20) and CEA + CA125 + NSE (78.8%, 41/52), respectively. Conclusions: Combined detection

  19. Diagnostic performance and prognostic value of extravascular retention of I-123-labeled serum amyloid P component in systemic amyloidosis

    NARCIS (Netherlands)

    Hazenberg, Bouke P. C.; van Rijswijk, Martin H.; Lub-de Hooge, Marjolijn N.; Vellenga, Edo; Haagsma, Elizabeth B.; Posthumus, Marcel D.; Jager, Pieter L.

    Serum amyloid P component (SAP) binds to amyloid.I-123-SAP scintigraphy is used to evaluate the extent and distribution of amyloid in systemic amyloidosis and has great clinical value in the detection of systemic amyloidosis. The aim of the study was to assess during scintigraphy the diagnostic

  20. Density functional theory calculations of H/D isotope effects on polymer electrolyte membrane fuel cell operations

    Energy Technology Data Exchange (ETDEWEB)

    Yanase, Satoshi; Oi, Takao [Sophia Univ., Tokyo (Japan). Faculty of Science and Technology

    2015-10-01

    To elucidate hydrogen isotope effects observed between fuel and exhaust hydrogen gases during polymer electrolyte membrane fuel cell operations, H-to-D reduced partition function ratios (RPFRs) for the hydrogen species in the Pt catalyst phase of the anode and the electrolyte membrane phase of the fuel cell were evaluated by density functional theory calculations on model species of the two phases. The evaluation yielded 3.2365 as the value of the equilibrium constant of the hydrogen isotope exchange reaction between the two phases at 39 C, which was close to the experimentally estimated value of 3.46-3.99 at the same temperature. It was indicated that H{sup +} ions on the Pt catalyst surface of the anode and H species in the electrolyte membrane phase were isotopically in equilibrium with one another during fuel cell operations.

  1. Nanoporous Hybrid Electrolytes for High-Energy Batteries Based on Reactive Metal Anodes

    Energy Technology Data Exchange (ETDEWEB)

    Tu, Zhengyuan [Department of Materials Science and Engineering, Cornell University, Ithaca NY 14850 USA; Zachman, Michael J. [School of Applied and Engineering Physics, Cornell University, Ithaca NY 14850 USA; Choudhury, Snehashis [School of Chemical Engineering and Biomolecular Engineering, Cornell University, Ithaca NY 14850 USA; Wei, Shuya [School of Chemical Engineering and Biomolecular Engineering, Cornell University, Ithaca NY 14850 USA; Ma, Lin [Department of Materials Science and Engineering, Cornell University, Ithaca NY 14850 USA; Yang, Yuan [Department of Chemistry and Geochemistry, Colorado School of Mines, Golden CO 80401 USA; Kourkoutis, Lena F. [School of Applied and Engineering Physics, Cornell University, Ithaca NY 14850 USA; Kavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca NY 14853 USA; Archer, Lynden A. [Department of Materials Science and Engineering, Cornell University, Ithaca NY 14850 USA; School of Chemical Engineering and Biomolecular Engineering, Cornell University, Ithaca NY 14850 USA

    2017-01-06

    Successful strategies for stabilizing electrodeposition of reactive metals, including lithium, sodium, and aluminum are a requirement for safe, high-energy electrochemical storage technologies that utilize these metals as anodes. Unstable deposition produces high-surface area dendritic structures at the anode/electrolyte interface, which causes premature cell failure by complex physical and chemical processes that have presented formidable barriers to progress. Here, it is reported that hybrid electrolytes created by infusing conventional liquid electrolytes into nanoporous membranes provide exceptional ability to stabilize Li. Electrochemical cells based on γ-Al2O3 ceramics with pore diameters below a cut-off value above 200 nm exhibit long-term stability even at a current density of 3 mA cm-2. The effect is not limited to ceramics; similar large enhancements in stability are observed for polypropylene membranes with less monodisperse pores below 450 nm. These findings are critically assessed using theories for ion rectification and electrodeposition reactions in porous solids and show that the source of stable electrodeposition in nanoporous electrolytes is fundamental.

  2. Nanoporous Hybrid Electrolytes for High-Energy Batteries Based on Reactive Metal Anodes

    KAUST Repository

    Tu, Zhengyuan

    2017-01-06

    Successful strategies for stabilizing electrodeposition of reactive metals, including lithium, sodium, and aluminum are a requirement for safe, high-energy electrochemical storage technologies that utilize these metals as anodes. Unstable deposition produces high-surface area dendritic structures at the anode/electrolyte interface, which causes premature cell failure by complex physical and chemical processes that have presented formidable barriers to progress. Here, it is reported that hybrid electrolytes created by infusing conventional liquid electrolytes into nanoporous membranes provide exceptional ability to stabilize Li. Electrochemical cells based on γ-Al2O3 ceramics with pore diameters below a cut-off value above 200 nm exhibit long-term stability even at a current density of 3 mA cm−2. The effect is not limited to ceramics; similar large enhancements in stability are observed for polypropylene membranes with less monodisperse pores below 450 nm. These findings are critically assessed using theories for ion rectification and electrodeposition reactions in porous solids and show that the source of stable electrodeposition in nanoporous electrolytes is fundamental.

  3. Phthaloylchitosan-Based Gel Polymer Electrolytes for Efficient Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    S. N. F. Yusuf

    2014-01-01

    Full Text Available Phthaloylchitosan-based gel polymer electrolytes were prepared with tetrapropylammonium iodide, Pr4NI, as the salt and optimized for conductivity. The electrolyte with the composition of 15.7 wt.% phthaloylchitosan, 31.7 wt.% ethylene carbonate (EC, 3.17 wt.% propylene carbonate (PC, 19.0 wt.% of Pr4NI, and 1.9 wt.% iodine exhibits the highest room temperature ionic conductivity of 5.27 × 10−3 S cm−1. The dye-sensitized solar cell (DSSC fabricated with this electrolyte exhibits an efficiency of 3.5% with JSC of 7.38 mA cm−2, VOC of 0.72 V, and fill factor of 0.66. When various amounts of lithium iodide (LiI were added to the optimized gel electrolyte, the overall conductivity is observed to decrease. However, the efficiency of the DSSC increases to a maximum value of 3.71% when salt ratio of Pr4NI : LiI is 2 : 1. This cell has JSC, VOC and fill factor of 7.25 mA cm−2, 0.77 V and 0.67, respectively.

  4. Diagnostic values of serum tumor markers Cyfra21-1, SCCAg, ferritin, CEA, CA19-9, and AFP in oral/oropharyngeal squamous cell carcinoma.

    Science.gov (United States)

    Yuan, Chuanshu; Yang, Kai; Tang, Hong; Chen, Dan

    2016-01-01

    At present, the research on serum tumor markers in the early diagnosis of malignant tumors has aroused widespread concern. The aim of this study was to investigate the diagnostic values of serum tumor markers cytokeratin 19 fragment (Cyfra21-1), squamous cell carcinoma antigen (SCCAg), ferritin, carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA19-9), and α-fetoprotein (AFP) for patients with oral/oropharyngeal squamous carcinoma (OSCC/OPSCC). One hundred and sixty-nine cases of patients with OSCC/OPSCC as the experimental group, 86 cases of oral benign tumor patients as the control group, and 30 cases of healthy people as the normal control group were studied. The levels of serum Cyfra21-1, SCCAg, ferritin, CEA, CA19-9, and AFP were measured using electrochemiluminescence immunoassay. The levels of serum Cyfra21-1, SCCAg, ferritin, and CEA in patients with OSCC/OPSCC were significantly higher than those of benign tumor and healthy control group (Ptumor, and healthy group (P>0.05). The level of serum Cyfra21-1 in patients with early OSCC/OPSCC (stage I + II) was significantly higher than that of benign tumor and healthy control group (PCEA, CA19-9, and AFP showed no significant difference between patients with early OSCC/OPSCC, benign tumor, and healthy control group (P>0.05). The levels of serum Cyfra21-1, SCCAg, ferritin, and CEA in the middle-late stage of patients with OSCC/OPSCC (stage III + IV) were significantly higher than those of patients with the early OSCC/OPSCC, benign tumor, and healthy control group (PCEA were 2.17, 0.72, 109.95, and 1.99 ng/mL, respectively. The sensitivities were 60.36%, 73.37%, 81.66%, and 66.27%, respectively. The specificities were 81.03%, 68.10%, 40.52%, and 61.21%, respectively. Cyfra21-1, SCCAg, ferritin, and CEA had diagnostic values for patients with OSCC/OPSCC. Meanwhile, Cyfra21-1 had better early diagnostic value for patients with OSCC/OPSCC.

  5. Effect of surface states of layered double hydroxides on conductive and transport properties of nanocomposite polymer electrolytes

    International Nuclear Information System (INIS)

    Liao, C.-S.; Ye, W.-B.

    2004-01-01

    All solid-state poly(ethylene oxide) (PEO) nanocomposite electrolytes were made containing nanoscale fillers of layered double hydroxides (LDHs). Two kinds of LDHs with different surface states were prepared by aqueous co-precipitation method. The LDHs were added into PEO matrix to study the structures, conductivities and ionic transport properties of nanocomposite electrolytes. The structures of LDHs were characterized by infrared spectra, thermogravimetric analysis and wide-angle X-ray diffraction. With enhanced compatibility of LDH sheets by oligo(ethylene oxide) surface modification, the PEO/OMLDH nanocomposite electrolyte exhibits an amorphous morphology and an enhancement of conductivity by three orders of magnitude as compared to pure PEO electrolyte. The lithium ion transference number T Li + of PEO/LDH nanocomposite electrolyte measured with a value of 0.42 is two times higher than the one of pure PEO electrolyte, which can be attributed to the Lewis acid-base interaction between surface states of metal hydroxides and counter anions of lithium salts

  6. Electrolytes for lithium and lithium-ion batteries

    CERN Document Server

    Jow, T Richard; Borodin, Oleg; Ue, Makoto

    2014-01-01

    Electrolytes for Lithium and Lithium-ion Batteries provides a comprehensive overview of the scientific understanding and technological development of electrolyte materials in the last?several years. This book covers key electrolytes such as LiPF6 salt in mixed-carbonate solvents with additives for the state-of-the-art Li-ion batteries as well as new electrolyte materials developed recently that lay the foundation for future advances.?This book also reviews the characterization of electrolyte materials for their transport properties, structures, phase relationships, stabilities, and impurities.

  7. THE COLLOIDAL BEHAVIOR OF SERUM GLOBULIN

    Science.gov (United States)

    Hitchcock, David I.

    1922-01-01

    1. The globulin prepared from ox serum by dilution and precipitation with carbon dioxide has been found, by electrometric titration experiments, to behave like an amphoteric electrolyte, reacting stoichiometrically with acids and bases. 2. The potential difference developed between a solution of globulin chloride, phosphate, or acetate and a solution of the corresponding acid, free from protein, separated from the globulin by a collodion membrane, was found to be influenced by hydrogen ion concentration and salt concentration in the way predicted by Donnan's theory of membrane equilibrium. In experiments with sodium globulinate and sodium hydroxide it was found that the potential difference could be similarly explained. 3. The osmotic pressure of such solutions could be qualitatively accounted for by the Donnan theory, but exhibited a discrepancy which is explicable by analogy with certain experiments of Loeb on gelatin. 4. The application of Loeb's theory of colloidal behavior, which had previously been found to hold in the case of gelatin, casein, egg albumin, and edestin, has thus been extended to another protein, serum globulin. PMID:19871977

  8. Electrolytes imbalance in saltwater near-drowning victims in the Gulf of Thailand.

    Science.gov (United States)

    Yongsiri, Somchai; Dinchuthai, Pakapan; Thammakumpee, Jiranuch; Prongnamchai, Suriya; Chueansuwan, Rachaneeporn; Tangjaturonrasme, Siriporn; Chaivanit, Pechngam

    2013-10-01

    Near-drowning victims in saltwater are expected to have multiple electrolytes imbalance that affected treatment outcome. There are limited data about these parameters in Thailand to guide the treatment plan. To study the characteristic of electrolytes imbalance in saltwater near-drowning victims in the Gulf of Thailand. Retrospective analytic study of 39 medical records of near-drowning patients admitted to Burapha University Hospital between 2000 and 2010. Characteristics of the patients and serum electrolytes were analyzed by SPSS version 19 for windows. The study included 23 male, 16 female patients. Average age was 14.46 +/- 11.15 years and 19/39 (48.72%) patients were aged 10 or less. The following electrolytes imbalance were identified, hypokalemia 8/39 (20.51%), hypernatremia 12/39 (30.77%), hyperchloremia 15/39 (38.46%), high anion gap 23/39 (58.97%), and hypobicarbonatemia 28/39 (71.79%). Seven out of eight patients in the hypokalemia group were in the high anion gap group. Mean SpO2 in the patients who had high anion gap was significantly lower than those who had normal anion gap (87.06 +/- 17.68% vs. 95.8 +/- 5.94% p = 0.031) without difference in systolic blood pressure (112.59 +/- 14.63 vs. 105.67 +/- 13.98 p = 0.159). Those who were hypotensive significantly had lower bicarbonate (17.00 +/- 3.51 vs. 20.59 +/- 3.81 p = 0.038) and higher anion gap (19.29 +/- 1.799 vs. 16.25 +/- 6.25 p = 0.025) than normotensive patients. Hypobicarbonatemia, high anion gap, hypernatremia, and hypokalemia were common in saltwater near-drowning patients in the Gulf of Thailand. The cause of high anion gap was probably due to hypoxia and hypotension.

  9. Significance and prognostic value of increased serum direct bilirubin level for lymph node metastasis in Chinese rectal cancer patients.

    Science.gov (United States)

    Gao, Chun; Fang, Long; Li, Jing-Tao; Zhao, Hong-Chuan

    2016-02-28

    To determine the significance of increased serum direct bilirubin level for lymph node metastasis (LNM) in Chinese rectal cancer patients, after those with known hepatobiliary and pancreatic diseases were excluded. A cohort of 469 patients, who were treated at the China-Japan Friendship Hospital, Ministry of Health (Beijing, China), in the period from January 2003 to June 2011, and with a pathological diagnosis of rectal adenocarcinoma, were recruited. They included 231 patients with LNM (49.3%) and 238 patients without LNM. Follow-up for these patients was taken through to December 31, 2012. The baseline serum direct bilirubin concentration was (median/inter-quartile range) 2.30/1.60-3.42 μmol/L. Univariate analysis showed that compared with patients without LNM, the patients with LNM had an increased level of direct bilirubin (2.50/1.70-3.42 vs 2.10/1.40-3.42, P = 0.025). Multivariate analysis showed that direct bilirubin was independently associated with LNM (OR = 1.602; 95%CI: 1.098-2.338, P = 0.015). Moreover, we found that: (1) serum direct bilirubin differs between male and female patients; a higher concentration was associated with poor tumor classification; (2) as the baseline serum direct bilirubin concentration increased, the percentage of patients with LNM increased; and (3) serum direct bilirubin was associated with the prognosis of rectal cancer patients and higher values indicated poor prognosis. Higher serum direct bilirubin concentration was associated with the increased risk of LNM and poor prognosis in our rectal cancers.

  10. Prognostic value of the serum free light chain ratio in newly diagnosed myeloma: proposed incorporation into the international staging system.

    Science.gov (United States)

    Snozek, C L H; Katzmann, J A; Kyle, R A; Dispenzieri, A; Larson, D R; Therneau, T M; Melton, L J; Kumar, S; Greipp, P R; Clark, R J; Rajkumar, S V

    2008-10-01

    To determine if the serum free light chain (FLC) ratio has prognostic value in patients with symptomatic multiple myeloma (MM), baseline serum samples from a well-characterized cohort of 790 newly diagnosed MM patients were tested with the FLC assay. FLC ratio was calculated as kappa/lambda (reference range 0.26-1.65). On the basis of the distribution of values, a cutpoint kappa/lambda FLC ratio of 32 was chosen for further analysis. Overall survival was significantly inferior in patients with an abnormal FLC ratio of 32 (n=479) compared with those with an FLC ratio between 0.03 and 32 (n=311), with median survival of 30 versus 39 months, respectively. We incorporated abnormal FLC ratio with the International Staging System (ISS) risk factors (that is, albumin or=3.5 g/l), to create a risk stratification model with improved prognostic capabilities. Patients with 0, 1, 2 or 3 adverse risk factors had significantly different overall survival, with median survival times of 51, 39, 30 and 22 months, respectively (P<0.001). These findings suggest that the serum FLC ratio at initial diagnosis is an important predictor of prognosis in myeloma, and can be incorporated into the ISS for improved risk stratification.

  11. Mechanistic Study of Electrolyte Additives to Stabilize High-Voltage Cathode–Electrolyte Interface in Lithium-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Han [Chemical; Maglia, Filippo [BMW Group, Munich 80788, Germany; Lamp, Peter [BMW Group, Munich 80788, Germany; Amine, Khalil [Chemical; Chen, Zonghai [Chemical

    2017-12-13

    Current developments of electrolyte additives to stabilize electrode-electrolyte interface in Li-ion batteries highly rely on a trial-and-error search, which involves repetitive testing and intensive amount of resources. The lack of understandings on the fundamental protection mechanisms of the additives significantly increases the difficulty for the transformational development of new additives. In this study, we investigated two types of individual protection routes to build a robust cathode-electrolyte interphase at high potentials: (i) a direct reduction in the catalytic decomposition of the electrolyte solvent; and (ii) formation of a “corrosion inhibitor film” that prevents severely attack and passivation from protons that generated from the solvent oxidation, even the decomposition of solvent cannot not mitigated. Effect of three exemplary electrolyte additives: (i) lithium difluoro(oxalato)borate (LiDFOB); (ii) 3-hexylthiophene (3HT); and (iii) tris(hexafluoro-iso-propyl)phosphate (HFiP), on LiNi0.6Mn0.2Co0.2O2 (NMC 622) cathode were investigated to validate our hypothesis. It is demonstrated that understandings of both electrolyte additives and solvent are essential and careful balance between the cathode protection mechanism of additives and their side effects is critical to obtain optimum results. More importantly, this study opens up new directions of rational design of functional electrolyte additives for the next generation high-energy density lithium-ion chemistries.

  12. Composite polymer electrolytes based on MG49 and carboxymethyl cellulose from kenaf

    International Nuclear Information System (INIS)

    Jafirin, Serawati; Ahmad, Ishak; Ahmad, Azizan

    2013-01-01

    The development of 49% poly(methyl methacrylate)-grafted natural rubber (MG49) and carboxymethyl cellulose as a composite polymer electrolyte film incorporating LiCF 3 SO 3 were explored. Carboxymethyl cellulose was synthesized from kenaf bast fibres via carboxymethylation process by alkali catalyzed reaction of cellulose with sodium chloroacetate. Reflection fourier transform infrared (ATR-FTIR) spectroscopy showed the presence of carboxyl peak after modification of cellulose with sodium chloroacetate. X-ray diffraction (XRD) analysis revealed that the crystallinity of cellulose was decrease after synthesis. High performance composite polymer electrolytes were prepared with various composition of carboxymethyl cellulose (2–10 wt%) via solution-casting method. The conductivity was increased with carboxymethyl cellulose loading. The highest conductivity value achieved was 3.3 × 10 −7 Scm −1 upon addition of 6% wt carboxymethyl cellulose. 6% wt carboxymethyl cellulose composition showed the highest tensile strength value of 7.9 MPa and 273 MPa of modulus value which demonstrated high mechanical performance with accepatable level of ionic conductivity

  13. Composite polymer electrolytes based on MG49 and carboxymethyl cellulose from kenaf

    Science.gov (United States)

    Jafirin, Serawati; Ahmad, Ishak; Ahmad, Azizan

    2013-11-01

    The development of 49% poly(methyl methacrylate)-grafted natural rubber (MG49) and carboxymethyl cellulose as a composite polymer electrolyte film incorporating LiCF3SO3 were explored. Carboxymethyl cellulose was synthesized from kenaf bast fibres via carboxymethylation process by alkali catalyzed reaction of cellulose with sodium chloroacetate. Reflection fourier transform infrared (ATR-FTIR) spectroscopy showed the presence of carboxyl peak after modification of cellulose with sodium chloroacetate. X-ray diffraction (XRD) analysis revealed that the crystallinity of cellulose was decrease after synthesis. High performance composite polymer electrolytes were prepared with various composition of carboxymethyl cellulose (2-10 wt%) via solution-casting method. The conductivity was increased with carboxymethyl cellulose loading. The highest conductivity value achieved was 3.3 × 10-7 Scm-1 upon addition of 6% wt carboxymethyl cellulose. 6% wt carboxymethyl cellulose composition showed the highest tensile strength value of 7.9 MPa and 273 MPa of modulus value which demonstrated high mechanical performance with accepatable level of ionic conductivity.

  14. Effect upon biocompatibility and biocorrosion properties of plasma electrolytic oxidation in trisodium phosphate electrolytes.

    Science.gov (United States)

    Kim, Yu-Kyoung; Park, Il-Song; Lee, Kwang-Bok; Bae, Tae-Sung; Jang, Yong-Seok; Oh, Young-Min; Lee, Min-Ho

    2016-03-01

    Surface modification to improve the corrosion resistance and biocompatibility of the Mg-Al-Zn-Ca alloy was conducted via plasma electrolytic oxidation (PEO) in an electrolyte that included phosphate. Calcium phosphate can be easily induced on the surface of a PEO coating that includes phosphate in a physiological environment because Ca(2+) ions in body fluids can be combined with PO4 (3-). Cytotoxicity of the PEO coating formed in electrolytes with various amounts of Na3PO4 was identified. In particular, the effects that PEO films have upon oxidative stress and differentiation of osteoblast activity were studied. As the concentration of Na3PO4 in the electrolyte increased, the oxide layer was found to become thicker, which increased corrosion resistance. However, the PEO coating formed in electrolytes with over 0.2 M of added Na3PO4 exhibited more microcracks and larger pores than those formed in smaller Na3PO4 concentrations owing to a large spark discharge. A nonuniform oxide film that included more phosphate caused more cytotoxicity and oxidative stress, and overabundant phosphate content in the oxide layer interrupted the differentiation of osteoblasts. The corrosion resistance of the magnesium alloy and the thickness of the oxide layer were increased by the addition of Na3PO4 in the electrolyte for PEO treatment. However, excessive phosphate content in the oxide layer led to oxidative stress, which resulted in reduced cell viability and activity.

  15. Potential role of peroxisome proliferator activated receptor gamma activation on serum visfatin and trace elements in high fat diet induced type 2 diabetes mellitus.

    Science.gov (United States)

    Tabassum, Arshia; Zaidi, Syeda Nuzhat Fatima; Yasmeen, Kausar; Mahboob, Tabassum

    2018-07-15

    Electrolytes and trace elements dysregulation play an important role in the progression of obesity and diabetes complications. The present study was designed to evaluate the insulin sensitizing effects of peroxisomes proliferators activated receptor gamma (PPAR-γ) agonist on trace elements in obesity induced type 2 diabetes mellitus and correlate with serum visfatin. Wistar rats were categorized into five groups. Group I served as control; Group II fed on high fat diet (HFD); Group III fed on HFD and treated with rosiglitazone (3 mg/kg) for 7 days; Group IV were T2DM rats induce by HFD and low dose of streptozotocin (i.p. 35 mg/kg); Group V was T2DM rats treated with rosiglitazone (3 mg/kg) for 7 days. Serum and tissues electrolytes levels and renal, hepatic and cardiac tissues trace elements were estimated by flame photometer and atomic absorption spectroscopy. Serum visfatin was estimated by ELISA. Pearson correlations were analyzed among fasting blood glucose (FBG), serum visfatin and tissues trace elements. Results of the current study showed hyponatremia, hyperkalemia, hypomagnesemia and hypercalcemia in HFD and T2DM groups. HFD and T2DM also showed elevated copper and iron levels; however, zinc and selenium levels were decreased. Rosiglitazone treatment increased the insulin sensitization and altered these changes. A Strong association was observed among FBG, serum visfatin and trace elements levels of HFD and T2DM. Obesity and diabetes mellitus disturbed visfatin, electrolytes and trace elements homeostasis. Rosiglitazone treatment restored these changes. The results of the study could serve as a basis for further studies for the prevention of diabetic complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Non-aqueous electrolytes for lithium ion batteries

    Science.gov (United States)

    Chen, Zonghai; Amine, Khalil

    2015-11-12

    The present invention is generally related to electrolytes containing anion receptor additives to enhance the power capability of lithium-ion batteries. The anion receptor of the present invention is a Lewis acid that can help to dissolve LiF in the passivation films of lithium-ion batteries. Accordingly, one aspect the invention provides electrolytes comprising a lithium salt; a polar aprotic solvent; and an anion receptor additive; and wherein the electrolyte solution is substantially non-aqueous. Further there are provided electrochemical devices employing the electrolyte and methods of making the electrolyte.

  17. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.; Buttner, Ulrich; Yi, Ying

    2016-01-01

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  18. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.

    2016-03-31

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  19. Electrolyte chemistry control in electrodialysis processing

    Science.gov (United States)

    Hayes, Thomas D.; Severin, Blaine F.

    2017-12-26

    Methods for controlling electrolyte chemistry in electrodialysis units having an anode and a cathode each in an electrolyte of a selected concentration and a membrane stack disposed therebetween. The membrane stack includes pairs of cationic selective and anionic membranes to segregate increasingly dilute salts streams from concentrated salts stream. Electrolyte chemistry control is via use of at least one of following techniques: a single calcium exclusionary cationic selective membrane at a cathode cell boundary, an exclusionary membrane configured as a hydraulically isolated scavenger cell, a multivalent scavenger co-electrolyte and combinations thereof.

  20. Structural, thermal and ion transport properties of radiation grafted lithium conductive polymer electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Nasef, Mohamed Mahmoud [Business and Advanced Technology Centre (BATC), Universiti Teknologi Malaysia, Jalan Semarak, 54100 Kuala Lumpur (Malaysia)]. E-mail: mahmoudeithar@mailcity.com; Saidi, Hamdani [Business and Advanced Technology Centre (BATC), Universiti Teknologi Malaysia, Jalan Semarak, 54100 Kuala Lumpur (Malaysia)

    2006-10-10

    Structural, thermal and ion transport properties of lithium conductive polymer electrolytes prepared by radiation-induced grafting of styrene onto poly(vinylidene fluoride) (PVDF) films and subsequent activation with LiPH{sub 6}/EC/DEC liquid electrolyte were investigated in correlation with the content of the grafted polystyrene (Y%). The changes in the structure were studied using Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Thermal gravimetric analysis (TGA) was used to evaluate the thermal stability. The ionic conductivity was measured by means of ac impedance spectroscopy at various temperatures. The polymer electrolytes were found to undergo considerable structural and morphological changes that resulted in a noticeable increase in their ionic conductivity with the increase in Y% at various temperatures (25-65 deg. C). The ionic conductivity achieved a value of 1.61 x 10{sup -3} S cm{sup -1} when Y of the polymer electrolyte reached 50% and at 25 deg. C. The polymer electrolytes also showed a multi-step degradation behaviour and thermal stability up to 120 deg. C, which suits normal lithium battery operation temperature range. The overall results of this work suggest that the structural changes took place in PVDF matrix during the preparation of these polymer electrolytes have a strong impact on their various properties.

  1. Diagnostic value of combined determination of serum AFP, CEA, CA199, SF levels in patients with primary hepatic carcinoma

    International Nuclear Information System (INIS)

    Wu Jiaming; Rui Zhilian

    2005-01-01

    Objective: To investigate the diagnostic value of combined detection of four tumor markers in patients with possible malignant change in liver disorders. Methods: Serum AFP, CEA, CA199 and SF levels were determined with chemiluminescence immunoassay (CLIA) in 49 patients with primary liver carcinoma, 7 patients with metastatic liver carcinoma, 40 patients with hepatic cirrhosis, 47 patients with HBV hepatitis and 30 controls. Results: The serum levels of AFP, CEA, SF in patients with primary hepatic cancer and serum levels of AFP, SF in patients with hepatic cirrhosis were all significantly higher than those in controls (P 0.05). Moreover, positive rate of combined determination of AFP, CEA, CA199, SF in patients with primary hepatic cancer was significantly higher than that in patients with metastatic liver cancer. Conclusion: With combined determination of these four tumor markers, the detection rate of primary hepatic carcinoma could be enhanced to above 95%. Also, differential diagnosis between primary and metastatic hepatic cancers could be facilitated. (authors)

  2. Conductivity studies of PEG based polymer electrolyte for applications as electrolyte in ion batteries

    Science.gov (United States)

    Patil, Ravikumar V.; Praveen, D.; Damle, R.

    2018-05-01

    Development of lithium ion batteries employing solid polymer electrolytes as electrolyte material has led to efficient energy storage and usage in many portable devices. However, due to a few drawbacks like lower ionic conductivity of solid polymer electrolytes (SPEs), studies on SPEs for improvement in conductivity still have a good scope. In the present paper, we report the conductivity studies of a new SPE with low molecular weight poly ethylene glycol (PEG) as host polymer in which a salt with larger anion Lithium trifluro methane sulphonate (LTMS). XRD studies have revealed that the salt completely dissociates in the polymer giving a good stable electrolyte at lower salt concentration. Conductivity of the SPEs has been studied as a function of temperature and we reiterate that the conductivity is a thermally activated process and follows Arrhenius type behavior.

  3. Dextran based highly conductive hydrogel polysulfide electrolyte for efficient quasi-solid-state quantum dot-sensitized solar cells

    International Nuclear Information System (INIS)

    Chen, Hong-Yan; Lin, Ling; Yu, Xiao-Yun; Qiu, Kang-Qiang; Lü, Xian-Yong; Kuang, Dai-Bin; Su, Cheng-Yong

    2013-01-01

    Highlights: ► Dextran based hydrogel is first used to prepare quasi-solid-state polysulfide electrolyte for quantum dot-sensitized solar cells. ► The ion conductivity of hydrogel electrolyte shows almost the same value as the liquid electrolyte. ► The liquid state at elevated temperature of hydrogel electrolyte allows for a good contact between electrolyte and CdS/CdSe co-sensitized TiO 2 photoanode. ► The hydrogel electrolyte based cell exhibits slightly lower power conversion efficiency than that of liquid electrolyte based cell. ► The dynamic electron transfer mechanism in hydrogel electrolyte based cell is examined in detail by EIS and CIMPS/IMVS. -- Abstract: Highly conductive hydrogel polysulfide electrolyte is first fabricated using dextran as gelator and used as quasi-solid-state electrolyte for quantum dot-sensitized solar cells (QDSSCs). The hydrogel electrolyte with gelator concentration of 15 wt% shows almost the same conductivity as the liquid one. Moreover, its liquid state at elevated temperature allow for the well penetration into the pores in electrodeposited CdS/CdSe co-sensitized TiO 2 photoanode. This gel electrolyte based QDSSC exhibits power conversion efficiency (η) of 3.23% under AG 1.5 G one sun (100 mW cm −2 ) illumination, slightly lower than that of liquid electrolyte based cell (3.69%). The dynamic electron transfer mechanism of the gel and liquid electrolyte based QDSSC are examined by electrochemical impedance spectroscopy (EIS) and controlled intensity modulated photocurrent/photovoltage spectroscopy (CIMPS/IMVS). It is found that the electron transport in gel electrolyte based cell is much faster than the liquid electrolyte based cell but it tends to recombine more easily than the latter. However, these differences fade away with increasing the light intensity, showing declining electron collection efficiency at higher light intensity illumination. As a result, a conversion efficiency of 4.58% is obtained for the gel

  4. Value of serum tenascin-C in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Rania Gaber

    2016-09-01

    Conclusions: Serum TN-C might be a novel marker reflecting active structural remodeling in the myocardium following infarction, with high TN-C levels at acute stages possibly predicting progression of LV remodeling. Also, the incorporation of a combination of serum TN-C and plasma BNP levels may improve risk stratification for congestive heart failure after AMI. Further studies on large scale are needed for more evaluation of TN-C role in HF.

  5. Reproducibility of whole-body {sup 131}I scan and serum thyrotropin and stimulated thyroglobulin values in patients studied twice after injection of recombinant human thyrotropin

    Energy Technology Data Exchange (ETDEWEB)

    Niederkohr, Ryan D.; McDougall, I.R. [Stanford University Medical Center, Division of Nuclear Medicine, Stanford, CA (United States)

    2007-03-15

    Recombinant human TSH (rhTSH) is used to increase radioiodine uptake during imaging of thyroid cancer, obviating the need to render the patient hypothyroid. We assessed the reproducibility of radioiodine uptake, serum thyrotropin (TSH), and stimulated serum thyroglobulin (Tg) levels after rhTSH administration. A retrospective review was performed of patients at Stanford who underwent whole-body {sup 131}I scanning for surveillance of thyroid cancer twice after thyroidectomy and {sup 131}I ablation, with rhTSH prior to each scan. Forty-eight hour radioiodine uptake, peak serum TSH, and stimulated serum Tg levels for each study were recorded. Paired t tests and correlation analysis were used to assess interexamination repeatability. Twenty-three patients underwent two scintiscans with rhTSH, for a total of 46 exams. There was no significant difference between percent uptake at 48 h in the paired exams (p=0.40). Serum TSH level was measured in 45 of 46 exams; TSH exceeded 50 mIU/l in all cases, and there was no significant difference between paired TSH levels (p=0.93). All patients had stimulated serum Tg levels measured, with no significant difference between paired Tg levels (p=0.40); after excluding one patient whose Tg changed from 15.8 ng/ml to undetectable between scans without interval treatment, the p value rose to 0.95. There was a strong correlation among paired uptake values (r=0.85, p<0.0001), peak serum TSH (r=0.69, p=0.0003), and stimulated Tg levels (r=0.81, p<0.0001). No discordant scan interpretations were reported. Forty-eight hour radioiodine uptake, peak serum TSH, and stimulated serum Tg levels after administration of rhTSH are repeatable between studies, demonstrating reproducibility of diagnostic results without rendering patients hypothyroid. (orig.)

  6. Plasma electrolytic oxidation of titanium in a phosphate/silicate electrolyte and tribological performance of the coatings

    International Nuclear Information System (INIS)

    Aliasghari, S.; Skeldon, P.; Thompson, G.E.

    2014-01-01

    Highlights: • Plasma electrolytic oxidation performed of titanium in silicate/phosphate electrolyte. • Range of duty cycle, current density, positive-to-negative current ratio studied. • Coatings contain anatase, rutile, Ti 3 O 5 , and amorphous silica. • Ptfe incorporated into coatings by addition of ptfe emulsion to the electrolyte. • Fiction reduced but wear life relatively short due to porosity of coatings. - Abstract: Plasma electrolytic oxidation of titanium has been investigated using a phosphate/silicate electrolyte with a square waveform and a frequency of 50 Hz. A range of constant rms current densities, duty cycles and negative-to-positive current ratios was employed. The resultant coatings were examined by analytical scanning and transmission electron microscopies and X-ray diffraction. The coatings, which were limited in thickness to ∼40 to 50 μm, contained anatase, rutile, Ti 2 O 5 and silicon-rich, amorphous material. The tribological behaviour was investigated using a ball-on-disc test, revealing a coefficient of friction against steel of ∼0.8, which reduced to ∼0.4 by incorporation of ptfe particles from the electrolyte. However, due to the composition and morphology of the coatings, their wear life was relatively short

  7. Solid electrolytes

    Science.gov (United States)

    Abraham, Kuzhikalail M.; Alamgir, Mohamed

    1993-06-15

    This invention pertains to Li ion (Li.sup.+) conductive solid polymer electrolytes composed of solvates of Li salts immobilized (encapsulated) in a solid organic polymer matrix. In particular, this invention relates to solid polymer electrolytes derived by immobilizing complexes (solvates) formed between a Li salt such as LiAsF.sub.6, LiCF.sub.3 SO.sub.3 or LiClO.sub.4 and a mixture of aprotic organic solvents having high dielectric constants such as ethylene carbonate (EC) (dielectric constant=89.6) and propylene carbonate (PC) (dielectric constant=64.4) in a polymer matrix such as polyacrylonitrile, poly(tetraethylene glycol diacrylate), or poly(vinyl pyrrolidinone).

  8. Silver precipitation from electrolytic effluents

    International Nuclear Information System (INIS)

    Rivera, I.; Patino, F.; Cruells, M.; Roca, A.; Vinals, J.

    2004-01-01

    The recovery of silver contained in electrolytic effluents is attractive due to its high economic value. These effluents are considered toxic wastes and it is not possible to dump them directly without any detoxification process. One of the most important way for silver recovery is the precipitation with sodium ditionite, sodium borohidride or hydrazine monohidrate. In this work, the most significant aspects related to the use of these reagents is presented. Results of silver precipitation with sodium ditionite from effluents containing thiosulfate without previous elimination of other species are also presented. silver concentration in the final effluents w <1 ppm. (Author) 15 refs

  9. Determination of intrinsic equilibrium constants at an alumina/electrolyte interface

    Directory of Open Access Journals (Sweden)

    SLOBODAN K. MILONJIC

    2004-12-01

    Full Text Available Intrinsic ionization and complexation constants at an alumina/electrolyte interface were studied by the site binding model, while the sorption of alkali cations from aqueous solutions was interpreted by the triple-layer model. The surface properties of alumina were investigated by the potentiometric acid-base titration method. The point of zero charge (pHpzc of alumina obtained by this method was found to be 7.2. The obtained mean values of the intrinsic protonation and ionization constants of the surface hydroxyl groups and the intrinsic surface complexation constant, in different electrolytes, are pKinta1 = 4.4, pKinta2 = 9.6 and pKintM+ = 9.5, respectively.

  10. Charge regulation at semiconductor-electrolyte interfaces.

    Science.gov (United States)

    Fleharty, Mark E; van Swol, Frank; Petsev, Dimiter N

    2015-07-01

    The interface between a semiconductor material and an electrolyte solution has interesting and complex electrostatic properties. Its behavior will depend on the density of mobile charge carriers that are present in both phases as well as on the surface chemistry at the interface through local charge regulation. The latter is driven by chemical equilibria involving the immobile surface groups and the potential determining ions in the electrolyte solution. All these lead to an electrostatic potential distribution that propagate such that the electrolyte and the semiconductor are dependent on each other. Hence, any variation in the charge density in one phase will lead to a response in the other. This has significant implications on the physical properties of single semiconductor-electrolyte interfaces and on the electrostatic interactions between semiconductor particles suspended in electrolyte solutions. The present paper expands on our previous publication (Fleharty et al., 2014) and offers new results on the electrostatics of single semiconductor interfaces as well as on the interaction of charged semiconductor colloids suspended in electrolyte solution. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The installation and dismantling of electrolytic cells

    International Nuclear Information System (INIS)

    Galushkin, N.V.

    1995-01-01

    This chapter of monograph is devoted to construction of aluminium electrolytic cells, their installation and dismantling. Therefore, the general characteristic and classification of aluminium electrolytic cells was considered. The anode and cathode structure was studied. The lining of cathode casing, the process of collection of anode gases, electrolytic cell cover, and electrical insulation was studied as well. The installation and dismantling of aluminium electrolytic cells was described.

  12. Application of several activity coefficient models to water-organic-electrolyte aerosols of atmospheric interest

    Directory of Open Access Journals (Sweden)

    T. Raatikainen

    2005-01-01

    Full Text Available In this work, existing and modified activity coefficient models are examined in order to assess their capabilities to describe the properties of aqueous solution droplets relevant in the atmosphere. Five different water-organic-electrolyte activity coefficient models were first selected from the literature. Only one of these models included organics and electrolytes which are common in atmospheric aerosol particles. In the other models, organic species were solvents such as alcohols, and important atmospheric ions like NH4+ could be missing. The predictions of these models were compared to experimental activity and solubility data in aqueous single electrolyte solutions with 31 different electrolytes. Based on the deviations from experimental data and on the capabilities of the models, four predictive models were selected for fitting of new parameters for binary and ternary solutions of common atmospheric electrolytes and organics. New electrolytes (H+, NH4+, Na+, Cl-, NO3- and SO42- and organics (dicarboxylic and some hydroxy acids were added and some modifications were made to the models if it was found useful. All new and most of the existing parameters were fitted to experimental single electrolyte data as well as data for aqueous organics and aqueous organic-electrolyte solutions. Unfortunately, there are very few data available for organic activities in binary solutions and for organic and electrolyte activities in aqueous organic-electrolyte solutions. This reduces model capabilities in predicting solubilities. After the parameters were fitted, deviations from measurement data were calculated for all fitted models, and for different data types. These deviations and the calculated property values were compared with those from other non-electrolyte and organic-electrolyte models found in the literature. Finally, hygroscopic growth factors were calculated for four 100 nm organic-electrolyte particles and these predictions were compared to

  13. Underscreening in concentrated electrolytes.

    Science.gov (United States)

    Lee, Alpha A; Perez-Martinez, Carla S; Smith, Alexander M; Perkin, Susan

    2017-07-01

    Screening of a surface charge by an electrolyte and the resulting interaction energy between charged objects is of fundamental importance in scenarios from bio-molecular interactions to energy storage. The conventional wisdom is that the interaction energy decays exponentially with object separation and the decay length is a decreasing function of ion concentration; the interaction is thus negligible in a concentrated electrolyte. Contrary to this conventional wisdom, we have shown by surface force measurements that the decay length is an increasing function of ion concentration and Bjerrum length for concentrated electrolytes. In this paper we report surface force measurements to test directly the scaling of the screening length with Bjerrum length. Furthermore, we identify a relationship between the concentration dependence of this screening length and empirical measurements of activity coefficient and differential capacitance. The dependence of the screening length on the ion concentration and the Bjerrum length can be explained by a simple scaling conjecture based on the physical intuition that solvent molecules, rather than ions, are charge carriers in a concentrated electrolyte.

  14. Carboxymethyl Cellulose From Kenaf Reinforced Composite Polymer Electrolytes Based 49 % Poly (Methyl Methacrylate)-Grafted Natural Rubber

    International Nuclear Information System (INIS)

    Serawati Jafirin; Ishak Ahmad; Azizan Ahmad; Ishak Ahmad; Azizan Ahmad

    2014-01-01

    Composite polymer electrolytes based 49 % poly(methyl methacrylate)-grafted natural rubber (MG49) incorporating lithium triflate (LiCF 3 SO 3 ) were prepared. The study mainly focuses on the ionic conductivity performances and mechanical properties. Prior to that, carboxymethyl cellulose was synthesized from kenaf fiber. The films were characterized by electrochemical impedance (EIS) spectroscopy, linear sweep voltammetry (LSV), universal testing machine and scanning electron microscopy (SEM). The conductivity was found to increase with carboxymethyl cellulose loading. The highest conductivity value achieved was 6.5 x 10 -6 Scm -1 upon addition of 6 wt % carboxymethyl cellulose. LSV graph shows the stability of this film was extended to 2.7 V at room temperature. The composition with 6 wt % carboxymethyl cellulose composition showed the highest tensile strength value of 7.9 MPa and 273 MPa of Young's modulus. The morphology of the electrolytes showed a smooth surface of films after addition of salt and filler indicating amorphous phase in electrolytes system. Excellent mechanical properties and good ionic conductivity are obtained, enlightening that the film is suitable for future applications as thin solid polymer electrolytes in lithium batteries. (author)

  15. Heavy-water extraction from non-electrolytic hydrogen streams

    International Nuclear Information System (INIS)

    LeRoy, R.L.; Hammerli, M.; Butler, J.P.

    1981-01-01

    Heavy water may be produced from non-electrolytic hydrogen streams using a combined electrolysis and catalytic exchange process. The method comprises contacting feed water in a catalyst column with hydrogen gas originating partly from a non-electrolytic hydrogen stream and partly from an electrolytic hydrogen stream, so as to enrich the feed water with the deuterium extracted from both the non-electrolytic and electrolytic hydrogen gas, and passing the deuterium water to an electrolyser wherein the electrolytic hydrogen gas is generated and then fed through the catalyst column. (L.L.)

  16. Polyethylene glycol 3350 without electrolytes: a new safe, effective, and palatable bowel preparation for colonoscopy in children.

    Science.gov (United States)

    Pashankar, Dinesh S; Uc, Aliye; Bishop, Warren P

    2004-03-01

    To assess safety, efficacy, and acceptance of polyethylene glycol 3350 without electrolytes (PEG) for bowel preparation for colonoscopy in children. Study design In a prospective study, 46 children (mean age, 11.2 years; range, 2.8-17.8) were given PEG at a dose of 1.5 g/kg/day for 4 days before colonoscopy. Patients were allowed to mix PEG in the beverage of their choice. Stool frequency and adverse effects were monitored during PEG therapy. Compliance, tolerance, and quality of colonic preparation were assessed. Serum electrolytes were measured before and after PEG therapy in 29 children. Daily stool frequency increased with PEG therapy from baseline of 2.6+/-0.3 to 3.0+/-0.5 on day 1, 4.6+/-0.4 on day 2, 5.5+/-0.7 on day 3, and 6.0+/-0.6 on day 4 (days 2, 3, and 4, PPEG therapy. Compliance and tolerance were rated as excellent by 89% and 85% of patients, respectively. Electrolyte-free PEG 3350 can be used as an effective and safe bowel preparation that is well accepted by children for colonoscopy.

  17. Standard guide for conducting and evaluating galvanic corrosion tests in electrolytes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1981-01-01

    1.1 This guide covers conducting and evaluating galvanic corrosion tests to characterize the behavior of two dissimilar metals in electrical contact in an electrolyte under low-flow conditions. It can be adapted to wrought or cast metals and alloys. 1.2 This guide covers the selection of materials, specimen preparation, test environment, method of exposure, and method for evaluating the results to characterize the behavior of galvanic couples in an electrolyte. Note 1—Additional information on galvanic corrosion testing and examples of the conduct and evaluation of galvanic corrosion tests in electrolytes are given in Refs (1) through (7). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicabil...

  18. Serum immunoreactive calcitonin concentration in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Dugard, J.; Kew, M.C.; Da Fonseca, M.; Levin, J.

    1982-01-01

    Having found raised serum calcitonin concentrations is 94% of patients with hepatocellular carcinoma when using a dextran-coated-charcoal radio-immunoassay, we have now repeated the study, using a double-antibody radio-immunoassay, in 102 further patients with hepatocellular carcinoma and 35 matched controls. Serum immunoreactive calcitonin concentrations (iCT) in the controls ranged from 10 to 310 pg/ml (mean 154,6 pg/ml). Values in the tumour patients ranged from 10 to 1 650 pg/ml (mean 302,6 pg/ml). The mean figures were significantly higher in the tumour patients (P smaller than 0,001), 35,5% of them having values above 310 pg/ml. In 65 of the patients serum iCT concentrations were also determined by dextran-coated-charcoal radio-immunoassay. Values ranged from 10 to 10780 pg/ml (mean 2 179 pg/ml). If 1 000 pg/ml is taken as the upper limit of normal, 69% of the patients had raised iCT concentrations. There was a good correlation (r=0,67; P smaller than 0,001) between serum iCT values measured with both methods in 50 patients. If measured by the double-antibody radio-immunoassay method, the serum calcitonin value is not useful as a marker for hepatocellular carcinoma

  19. Serum immunoreactive calcitonin concentration in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Dugard, J; Kew, M C; Da Fonseca, M; Levin, J [University of the Witwatersrand, Johannesburg (South Africa)

    1982-08-21

    Having found raised serum calcitonin concentrations in 94% of patients with hepatocellular carcinoma when using a dextran-coated-charcoal radio-immunoassay, we have now repeated the study, using a double-antibody radio-immunoassay, in 102 further patients with hepatocellular carcinoma and 35 matched controls. Serum immunoreactive calcitonin concentrations (iCT) in the controls ranged from 10 to 310 pg/ml (mean 154,6 pg/ml). Values in the tumour patients ranged from 10 to 1,650 pg/ml (mean 302,6 pg/ml). The mean figures were significantly higher in the tumour patients (P smaller than 0,001), 35.5% of them having values above 310 pg/ml. In 65 of the patients serum iCT concentrations were also determined by dextran-coated-charcoal radio-immunoassay. Values ranged from 10 to 10780 pg/ml (mean 2,179 pg/ml). If 1,000 pg/ml is taken as the upper limit of normal, 69% of the patients had raised iCT concentrations. There was a good correlation (r=0,67; P smaller than 0,001) between serum iCT values measured with both methods in 50 patients. If measured by the double-antibody radio-immunoassay method, the serum calcitonin value is not useful as a marker for hepatocellular carcinoma.

  20. Nuclear electrolytic hydrogen

    International Nuclear Information System (INIS)

    Barnstaple, A.G.; Petrella, A.J.

    1982-05-01

    An extensive study of hydrogen supply has recently been carried out by Ontario Hydro which indicates that electrolytic hydrogen produced from nuclear electricity could offer the lowest cost option for any future large scale hydrogen supply in the Province of Ontario, Canada. This paper provides a synopsis of the Ontario Hydro study, a brief overview of the economic factors supporting the study conclusion and discussion of a number of issues concerning the supply of electrolytic hydrogen by electric power utilities

  1. Electrolytic preconcentration in instrumental analysis.

    Science.gov (United States)

    Sioda, R E; Batley, G E; Lund, W; Wang, J; Leach, S C

    1986-05-01

    The use of electrolytic deposition as a separation and preconcentration step in trace metal analysis is reviewed. Both the principles and applications of the technique are dealt with in some detail. Electrolytic preconcentration can be combined with a variety of instrumental techniques. Special attention is given to stripping voltammetry, potentiometric stripping analysis, different combinations with atomic-absorption spectrometry, and the use of flow-through porous electrodes. It is pointed out that the electrolytic preconcentration technique deserves more extensive use as well as fundamental investigation.

  2. Manufacturing of Dysprosium-Iron Alloys by Electrolysis in Fluoride-Based Electrolytes: Oxide Solubility Determinations

    Science.gov (United States)

    Martinez, Ana Maria; Støre, Anne; Osen, Karen Sende

    2018-04-01

    Electrolytic production of light rare earth elements and alloys takes place in a fluoride-based electrolyte using rare earth oxides as raw material. The optimization of this method, mainly in terms of the energy efficiency and environmental impact control, is rather challenging. Anode effects, evolution of fluorine-containing compounds, and side cathode reactions could largely be minimized by a good control of the amount of rare earth oxide species dissolved in the fluoride-based electrolyte and their dissolution rate. The oxide content of the fluoride melts REF3-LiF (RE = Nd, Dy) at different compositions and temperatures were experimentally determined by carbothermal analysis of melt samples. The highest solubility values of oxide species, added as Dy2O3 and Dy2(CO3)3, were obtained to be of ca. 3 wt pct (expressed as Dy2O3) in the case of the equimolar DyF3-LiF melt at 1323 K (1050 °C). The oxide saturation values increased with the amount of REF3 present in the molten bath and the working temperature.

  3. Elevated serum magnesium associated with SGLT2 inhibitor use in type 2 diabetes patients: a meta-analysis of randomised controlled trials.

    Science.gov (United States)

    Tang, Huilin; Zhang, Xi; Zhang, Jingjing; Li, Yufeng; Del Gobbo, Liana C; Zhai, Suodi; Song, Yiqing

    2016-12-01

    By analysing available evidence from randomised controlled trials (RCTs), we aimed to examine whether and to what extent sodium-glucose cotransporter 2 (SGLT2) inhibitors affect serum electrolyte levels in type 2 diabetes patients. We searched PubMed, EMBASE, Cochrane Central Register of Controlled Trials (CENTRAL) and ClinicalTrials.gov up to 24 May 2016 for published RCTs of SGLT2 inhibitors that reported changes in serum electrolyte levels. Weighted mean differences (WMD) between each SGLT2 inhibitor and placebo were calculated using a random-effects model. Dose-dependent relationships for each SGLT2 inhibitor were evaluated using meta-regression analysis. Eighteen eligible RCTs, including 15,309 patients and four SGLT2 inhibitors (canagliflozin, dapagliflozin, empagliflozin and ipragliflozin) were evaluated. In patients without chronic kidney disease, each SGLT2 inhibitor significantly increased serum magnesium levels compared with placebo (canagliflozin: WMD 0.06 mmol/l for 100 mg and 0.09 mmol/l for 300 mg; dapagliflozin: WMD 0.1 mmol/l for 10 mg; empagliflozin: WMD 0.04 mmol/l for 10 mg and 0.07 mmol/l for 25 mg; and ipragliflozin: WMD 0.05 mmol/l for 50 mg). Canagliflozin increased serum magnesium in a linear dose-dependent manner (p = 0.10). Serum phosphate was significantly increased by dapagliflozin. Serum sodium appeared to significantly differ by SGLT2 inhibitor type. No significant changes in serum calcium and potassium were observed. Findings were robust after including trials involving patients with chronic kidney disease. SGLT2 inhibitors marginally increased serum magnesium levels in type 2 diabetes patients indicating a drug class effect. Further investigations are required to examine the clinical significance of elevated magnesium levels in individuals with type 2 diabetes.

  4. Ultrasonographic diagnosis of fatty liver and relations with body index, serum lipid, and serum triglyceride

    International Nuclear Information System (INIS)

    Jang, Young Deog; Lee, S. H.; Lee, H. K.; Kim, D. H.; Kwon, K. H.; Kim, K. C.

    1989-01-01

    Hepatic fatty infiltration appears as an area of increased echogenicity. And many factors concerned to fatty infiltration. With 65 cases of fatty liver and 42 cases of normal group, we analyzed fatty liver with grading and attempt to find relations between grade of fatty liver and levels of body index, serum triglyceride, and serum lipid. And compared fatty liver with normal control group. Patients with fatty liver are higher percentage of supra-normal value in body index, serum lipid, and serum triglyceride than normal control group. As fatty infiltration progressed, serum lipid, serum trig-lyceride and body index are also increased. Conclusively ultrasonographic examination of liver with serum triglyceride, serum lipid, and body index are simple method, useful follow-up examination of fatty liver, and preventive routine check-up of chronic liver disease

  5. Effect of activated carbon and electrolyte on properties of supercapacitor

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Effect of activated carbon and electrolyte on electrochemical properties of organic supercapacitor was investigated. The results show that specific surface area and mesoporosity of activated carbon influence specific capacitance. If specific surface area is larger and mesoporosity is higher, the specific capacitance will become bigger. Specific surface area influences resistance of carbon electrode and consequently influences power property and pore size distribution. If specific surface area is smaller and mesoporosity is higher, the power property will become better. Ash influences leakage current and electrochemical cycling stability. If ash content is lower, the performance will become better. The properties of supercapacitor highly depend on the electrolyte. The compatibility of electrolyte and activated carbon is a determining factor of supercapacitor's working voltage. LiPF6/(EC+EMC+DMC) is inappropriate for double layer capacitor. MeEt3NPF4/PC has higher specific capacitance than EtnNPFn/PC because methyl's electronegativity value is lower than ethyl and MeEt3N+ has more positive charges and stronger polarizability than Et4N+ when an ethyl is substituted by methyl.

  6. Thermodynamics of electrolytes. III. Activity and osmotic coefficients for 2-2 electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Pitzer, K.S.; Mayorga, G.

    1974-01-01

    The peculiar behavior of 2-2 and higher valence type electrolytes is discussed in terms of various theories some of which assume, while others do not, an equilibrium between separated ions and ion pairs as distinct chemical species. It is recognized that in some cases a distinct species of inner-shell ion pairs is indicated by spectroscopic or ultrasonic data. Nevertheless, there are many advantages in representing, if possible, the properties of these electrolytes by appropriate virial coefficients and without chemical association equilibria. It is shown that this is possible and is conveniently accomplished by the addition of these equations are given for nine solutes. It is also noted that these equations have been successfully applied to mixed electrolytes involving one component of the 2-2 type. 2 figures, 1 table.

  7. On the use of voltammetric methods to determine electrochemical stability limits for lithium battery electrolytes

    Science.gov (United States)

    Georén, Peter; Lindbergh, Göran

    In previous studies a novel amphiphilic co-polymer was developed for use in lithium-ion batteries. In order to evaluate the electrochemical stability of that electrolyte and compare it with others, a voltammetric method was applied on a set of electrolytes with different salts, solvents and polymers. However, initially the voltammetric methodology was studied. Platinum was found to be the most suited electrode material, experiencing no significant interfering reactions and a proper diffusion-controlled kinetic behaviour when sweep rate was varied. Furthermore, the influence on the voltammograms of adding water traces to the electrolytes was studied. It could be established that the oxidation peak around 3.8 V versus Li was related to water reactions. It was concluded that quantitative voltage values of the stability limits were difficult to assess using voltammetry. On the other hand, the method seemed well suited for comparison of electrolytes and to investigate the influences of electrolyte components on the stability. The voltammetric results varied little between the different electrolytes evaluated and the anodic and cathodic limits, as defined here, were in the range of 1 and 4.5 V vs. Li, respectively. Although the novel polymer did not affect the stability limit significantly it seemed to promote the breakdown reaction rate in all electrolytes tested. Furthermore, the use of LiTFSI salt reduced the stability window.

  8. Plasma electrolytic oxidation of titanium in a phosphate/silicate electrolyte and tribological performance of the coatings

    Energy Technology Data Exchange (ETDEWEB)

    Aliasghari, S.; Skeldon, P., E-mail: p.skeldon@manchester.ac.uk; Thompson, G.E.

    2014-10-15

    Highlights: • Plasma electrolytic oxidation performed of titanium in silicate/phosphate electrolyte. • Range of duty cycle, current density, positive-to-negative current ratio studied. • Coatings contain anatase, rutile, Ti{sub 3}O{sub 5}, and amorphous silica. • Ptfe incorporated into coatings by addition of ptfe emulsion to the electrolyte. • Fiction reduced but wear life relatively short due to porosity of coatings. - Abstract: Plasma electrolytic oxidation of titanium has been investigated using a phosphate/silicate electrolyte with a square waveform and a frequency of 50 Hz. A range of constant rms current densities, duty cycles and negative-to-positive current ratios was employed. The resultant coatings were examined by analytical scanning and transmission electron microscopies and X-ray diffraction. The coatings, which were limited in thickness to ∼40 to 50 μm, contained anatase, rutile, Ti{sub 2}O{sub 5} and silicon-rich, amorphous material. The tribological behaviour was investigated using a ball-on-disc test, revealing a coefficient of friction against steel of ∼0.8, which reduced to ∼0.4 by incorporation of ptfe particles from the electrolyte. However, due to the composition and morphology of the coatings, their wear life was relatively short.

  9. Nonflammable perfluoropolyether-based electrolytes for lithium batteries

    Science.gov (United States)

    Wong, Dominica H. C.; Thelen, Jacob L.; Fu, Yanbao; Devaux, Didier; Pandya, Ashish A.; Battaglia, Vincent S.; Balsara, Nitash P.; DeSimone, Joseph M.

    2014-01-01

    The flammability of conventional alkyl carbonate electrolytes hinders the integration of large-scale lithium-ion batteries in transportation and grid storage applications. In this study, we have prepared a unique nonflammable electrolyte composed of low molecular weight perfluoropolyethers and bis(trifluoromethane)sulfonimide lithium salt. These electrolytes exhibit thermal stability beyond 200 °C and a remarkably high transference number of at least 0.91 (more than double that of conventional electrolytes). Li/LiNi1/3Co1/3Mn1/3O2 cells made with this electrolyte show good performance in galvanostatic cycling, confirming their potential as rechargeable lithium batteries with enhanced safety and longevity. PMID:24516123

  10. Lithium-ion transport in inorganic solid state electrolyte

    International Nuclear Information System (INIS)

    Gao Jian; Li Hong; Zhao Yu-Sheng; Shi Si-Qi

    2016-01-01

    An overview of ion transport in lithium-ion inorganic solid state electrolytes is presented, aimed at exploring and designing better electrolyte materials. Ionic conductivity is one of the most important indices of the performance of inorganic solid state electrolytes. The general definition of solid state electrolytes is presented in terms of their role in a working cell (to convey ions while isolate electrons), and the history of solid electrolyte development is briefly summarized. Ways of using the available theoretical models and experimental methods to characterize lithium-ion transport in solid state electrolytes are systematically introduced. Then the various factors that affect ionic conductivity are itemized, including mainly structural disorder, composite materials and interface effects between a solid electrolyte and an electrode. Finally, strategies for future material systems, for synthesis and characterization methods, and for theory and calculation are proposed, aiming to help accelerate the design and development of new solid electrolytes. (topical review)

  11. Impedance studies of a green blend polymer electrolyte based on PVA and Aloe-vera

    Science.gov (United States)

    Selvalakshmi, S.; Mathavan, T.; Vijaya, N.; Selvasekarapandian, Premalatha, M.; Monisha, S.

    2016-05-01

    The development of polymer electrolyte materials for energy generating and energy storage devices is a challenge today. A new type of blended green electrolyte based on Poly-vinyl alcohol (PVA) and Aloe-vera has been prepared by solution casting technique. The blending of polymers may lead to the increase in stability due to one polymer portraying itself as a mechanical stiffener and the other as a gelled matrix supported by the other. The prepared blend electrolytes were subjected to Ac impedance studies. It has been found out that the polymer film in which 1 gm of PVA was dissolved in 40 ml of Aloe-vera extract exhibits highest conductivity and its value is 3.08 × 10-4 S cm-1.

  12. Serum elastase activity, serum elastase inhibitors, and occurrence of carotid atherosclerotic plaques: the Etude sur le Vieillissement Artériel (EVA) study.

    Science.gov (United States)

    Zureik, Mahmoud; Robert, Ladislas; Courbon, Dominique; Touboul, Pierre-Jean; Bizbiz, Latifa; Ducimetière, Pierre

    2002-06-04

    In the last decades, interest has increased in the potential deleterious atherogenic effects of some cellular elastase activities. The results of experimental and clinical investigations were inconsistent. In this report, we assessed the associations of serum elastase activity and serum elastase inhibitors with carotid plaque occurrence during the 4-year follow-up in a population of 859 subjects free of coronary heart disease and stroke (age, 59 to 71 years). Serum elastase activity and serum elastase inhibitors were measured at baseline examination. Carotid B-mode ultrasound examination was performed at baseline and 2 years and 4 years later. The occurrence of carotid plaques in subjects with the lowest serum elastase activity values (quartile 1), in those with the intermediate values (quartiles 2 to 3), and in those with the highest values (quartile 4) was, respectively, 24.6%, 18.9%, and 12.2% (P<0.001 for trend). The multivariate odds ratios of carotid plaque occurrence associated with the three groups (adjusted for major known cardiovascular risk factors) were, respectively, 1.00, 0.67 (CI, 0.44 to 1.02; P<0.06), and 0.40 (CI, 0.23 to 0.70, P<0.001). For serum elastase inhibitors, the occurrence of carotid plaques in quartile 1 (lowest values), quartiles 2 to 3, and quartile 4 (highest values) was, respectively, 11.7%, 18.8%, and 25.2% (P for trend<0.001). The corresponding multivariate adjusted odds ratios were 1.00, 1.98 (CI, 1.19 to 3.31, P<0.01), and 3.18 (CI, 1.80 to 5.60, P<0.001). Low values of serum elastase activity and high values of serum elastase inhibitors were strongly and independently associated with increased 4-year carotid plaque occurrence. Further studies are necessary to elucidate the nature of the associations between elastase parameters and atherosclerosis.

  13. Experimental studies on poly methyl methacrylate based gel polymer electrolytes for application in electrical double layer capacitors

    International Nuclear Information System (INIS)

    Hashmi, S A; Kumar, Ashok; Tripathi, S K

    2007-01-01

    Studies have been carried out on gel polymer electrolytes comprising poly methyl methacrylate (PMMA)-ethylene carbonate (EC)-propylene carbonate (PC)-salts, LiClO 4 , NaClO 4 and (C 2 H 5 ) 4 NClO 4 (TEAClO 4 ) with a view to using them as electrolytes in electrical double layer capacitors (EDLCs) based on activated charcoal powder electrodes. The optimum composition of gel electrolytes, PMMA (20 wt%)-EC : PC (1 : 1 v/v)-1.0 M salts exhibit high ionic conductivity of the order of ∼10 -3 S cm -1 at room temperature with good mechanical/dimensional stability, suitable for their application in EDLCs. The EDLCs have been characterized using linear sweep cyclic voltammetry, galvanostatic charge-discharge tests and ac impedance spectroscopy. The values of capacitance of 68-151 mF cm -2 (equivalent to single electrode specific capacitance of 38-78 Fg -1 of activated charcoal powder) have been observed. These values correspond to a specific energy of 5.3-10.8 Wh kg -1 and a power density of 0.19-0.22 kW kg -1 . The capacitance values have been observed to be stable up to 5000 voltammetric cycles or even more. A comparison of studies shows the predominant role of anions of the gel electrolytes in the capacitive behaviour of EDLCs

  14. Solid electrolyte fuel cells

    Science.gov (United States)

    Isaacs, H. S.

    Progress in the development of functioning solid electrolyte fuel cells is summarized. The solid electrolyte cells perform at 1000 C, a temperature elevated enough to indicate high efficiencies are available, especially if the cell is combined with a steam generator/turbine system. The system is noted to be sulfur tolerant, so coal containing significant amounts of sulfur is expected to yield satisfactory performances with low parasitic losses for gasification and purification. Solid oxide systems are electrically reversible, and are usable in both fuel cell and electrolysis modes. Employing zirconium and yttrium in the electrolyte provides component stability with time, a feature not present with other fuel cells. The chemical reactions producing the cell current are reviewed, along with materials choices for the cathodes, anodes, and interconnections.

  15. Adsorption of ions by colloids in electrolyte solutions

    International Nuclear Information System (INIS)

    Kallay, N.

    1977-01-01

    The adsorption isotherm for ionic adsorption by colloid particles was evaluated. The adsorption process was treated as the reaction between colloid particles and ions. The colloid particle has been here considered as a reaction entity. The possibility of the surface potential determination was presented. The analyses of the experimental data showed, that (at electrolyte concentration higher than the critical coagulation one) the surface potential reaches its zero value

  16. Serum ferritin, serum nitric oxide, and cognitive function in pediatric thalassemia major

    Directory of Open Access Journals (Sweden)

    Septiana Nur Qurbani

    2017-06-01

    Full Text Available Background Hemolysis and repeated blood transfusions in children with thalassemia major cause iron overload in various organs, including the brain, and may lead to neurodegeneration. Hemolysis also causes decreased levels of nitric oxide, which serves as a volume transmitter and slow dynamic modulation, leading to cognitive impairment. Objective To assess for correlations between serum ferritin as well as nitric oxide levels and cognitive function in children with thalassemia major.  Methods This analytical study with cross-sectional design on 40 hemosiderotic thalassemia major patients aged 6−14 years, was done at the Thalassemia Clinic in Dr. Hasan Sadikin Hospital, Bandung, West Java, from May to June 2015. Serum ferritin measurements were performed by an electrochemiluminescence immunoassay; serum nitric oxide was assayed by a colorimetric procedure based on Griess reaction; and cognitive function was assessed by the Wechsler Intelligence Scale for Children test. Statistical analysis was done using Spearman’s Rank correlation, with a significance value of 0.05. Results Abnormal values in verbal, performance, and full scale IQ were found in 35%, 57.5% and 57.5%, respectively. Serum nitric oxide level was significantly correlated with performance IQ (P=0.022, but not with verbal IQ (P=0.359 or full scale IQ (P=0.164. There were also no significant correlations between serum ferritin level and full scale, verbal, or performance IQ (P=0.377, 0.460, and 0.822, respectively. Conclusion Lower serum nitric oxide level is significantly correlated to lower cognitive function, specifically in the performance IQ category. However, serum ferritin level has no clear correlation with cognitive function.

  17. Diagnostic value of combined determination of serum and pleural effusion CEA, CYFRA21-1 and NSE levels in patients with malignancy

    International Nuclear Information System (INIS)

    Chen Xiaoxiao

    2008-01-01

    Objective: To study the clinical value of combined determination of serum and pleural effusion levels of CEA, CYFRA21-1 and NSE in patients with malignancy. Methods: Serum and pleural effusion CEA, CYFRA21-1 and NSE levels were measured with RIA in 40 patients with malignant and 32 patients with tuberculous pleural effusions. Results: The pleural effusion CEA, CYFRA21-1, NSE levels and pleural effusion serum levels ratio in malignant group were significantly higher than those in tuberculous group (P<0.01). The specificity of CEA (90%) was higher than those in that of CYFRA21-1 and NSE, and the sensitivity of CYFRA21-1 (83%) was higher than that of CEA and NSE. With combined detection of CEA, CYFRA21-1 and NSE, the sensitivity was 90% and the specificity was 89% for diagnosis of malignant pleural effusion. Conclusion: Combined determination of serum and pleural effusion CEA, CYFRA21-1 and NSE levels would be more sensitive for diagnosis of malignant pleural effusion. (authors)

  18. Biological Variation and Reference Change Value Data for Serum Neuron-Specific Enolase in a Turkish Population.

    Science.gov (United States)

    Matyar, Selcuk; Goruroglu Ozturk, Ozlem; Ziyanoglu Karacor, Esin; Yuzbasioglu Ariyurek, Sedefgul; Sahin, Gulhan; Kibar, Filiz; Yaman, Akgun; Inal, Tamer

    2016-11-01

    Neuron-specific enolase (NSE) is a recognized biomarker for the assessment of cerebral injury in neurological disorders. This study aims to report a definitive assessment of the biological variation (BV) components of this biomarker, including within-subject BV (CVI), between-subject BV (CVG), index of individuality (II), and reference change value (RCV), in a cohort of Turkish participants using an experimental protocol. Six blood specimens were collected from each of the 13 apparently healthy volunteers (seven women, six men; ranging in age from 23 to 36) on the same day, every 2 weeks for 2 months. Serum specimens were stored at -20°C until analysis. Neuron-specific enolase levels were evaluated in serum samples using an electrochemiluminescence (ECLIA) immunoassay kit with a Roche Cobas e 411 auto-analyser. ANOVA test was used to calculate the variations. The CVI and CVG for NSE were 21.5% and 28.8%, respectively. Analytical variation (CVA) was calculated as 10.2%. Additionally, II and RCV were calculated as 0.74 and 66% (95% confident interval, CI), respectively. As the performance index (PI) was found to be less than 2 (PI = 0.95), it is concluded that the NSE measurements have a desirable performance for analytical imprecision. Since the II was found to be less than 1 (II: 0.74), the reference values will be of little use. Thus, RCV would provide better information for deciding whether a significant change has occurred. © 2016 Wiley Periodicals, Inc.

  19. InGaN/GaN quantum dots as optical probes for the electric field at the GaN/electrolyte interface

    Science.gov (United States)

    Teubert, J.; Koslowski, S.; Lippert, S.; Schäfer, M.; Wallys, J.; Dimitrakopulos, G.; Kehagias, Th.; Komninou, Ph.; Das, A.; Monroy, E.; Eickhoff, M.

    2013-08-01

    We investigated the electric-field dependence of the photoluminescence-emission properties of InGaN/GaN quantum dot multilayers in contact with an electrolyte. Controlled variations of the surface potential were achieved by the application of external electric fields using the electrolytic Schottky contact and by variation of the solution's pH value. Prior to characterization, a selective electrochemical passivation process was required to suppress leakage currents. The quantum dot luminescence is strongly affected by surface potential variations, i.e., it increases exponentially with cathodic bias and acidic pH values. The results cannot be explained by a modification of intra-dot polarization induced electric fields via the quantum confined Stark effect but are attributed to the suppression/enhancement of non-radiative recombination processes, i.e., mainly hole transfer into the electrolyte. The results establish a link between the photoluminescence intensity and the magnitude of electric fields at the semiconductor/electrolyte interface.

  20. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  1. Composite polymer electrolytes based on MG49 and carboxymethyl cellulose from kenaf

    Energy Technology Data Exchange (ETDEWEB)

    Jafirin, Serawati; Ahmad, Ishak; Ahmad, Azizan [Polymer Research Centre (PORCE), School of Chemical Science and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    The development of 49% poly(methyl methacrylate)-grafted natural rubber (MG49) and carboxymethyl cellulose as a composite polymer electrolyte film incorporating LiCF{sub 3}SO{sub 3} were explored. Carboxymethyl cellulose was synthesized from kenaf bast fibres via carboxymethylation process by alkali catalyzed reaction of cellulose with sodium chloroacetate. Reflection fourier transform infrared (ATR-FTIR) spectroscopy showed the presence of carboxyl peak after modification of cellulose with sodium chloroacetate. X-ray diffraction (XRD) analysis revealed that the crystallinity of cellulose was decrease after synthesis. High performance composite polymer electrolytes were prepared with various composition of carboxymethyl cellulose (2–10 wt%) via solution-casting method. The conductivity was increased with carboxymethyl cellulose loading. The highest conductivity value achieved was 3.3 × 10{sup −7} Scm{sup −1} upon addition of 6% wt carboxymethyl cellulose. 6% wt carboxymethyl cellulose composition showed the highest tensile strength value of 7.9 MPa and 273 MPa of modulus value which demonstrated high mechanical performance with accepatable level of ionic conductivity.

  2. [Value of polymerase chain reaction in serum for the diagnosis of enteroviral meningitis].

    Science.gov (United States)

    Marque Juillet, S; Lion, M; Pilmis, B; Tomini, E; Dommergues, M-A; Laporte, S; Foucaud, P

    2013-06-01

    Enteroviruses (EV) are a common cause of aseptic meningitis in children. Virological diagnosis of EV meningitis is currently based on the detection of the viral genome in the cerebrospinal fluid (CSF). This study attempted to determine the correlation and the temporality of the polymerase chain reaction (PCR) assay in serum and CSF and to evaluate the possibility of diagnosing EV infection only on the serum PCR. The EV genome was sought by RT real-time PCR (Smart Cycler EV Primer and Probe Set(®), Cepheid) in CSF and serum, collected at the same time, for all children who underwent a lumbar puncture for suspected meningitis, between 1 June and 31 July 2010 at the Versailles Hospital. Forty-four patients were included in the study. EV infection was documented for 22 of them. In 10 patients, the EV genome was detected in CSF only; in 3 patients in serum only, and in 9 patients in both. Among patients with acute EV neurological infection, viremic children were significantly younger (1.6 months versus 5.8 years; Pvalue of EV PCR in serum. It suggests that in some children and under certain conditions (age >3 months, clinical and biological compatibility with a viral infection, no previous antibiotic therapy, time from symptom onset to blood sampling <30 h, PCR in serum analyzed within 3h), PCR in serum, when positive, is a possible alternative. Therefore, it may be possible to diagnose EV infection without performing a lumbar puncture in a limited number of young children (11.4% of our suspected cases). This study needs to be reinforced by a multicenter study with a broader panel of patients. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. 3D-Printing Electrolytes for Solid-State Batteries.

    Science.gov (United States)

    McOwen, Dennis W; Xu, Shaomao; Gong, Yunhui; Wen, Yang; Godbey, Griffin L; Gritton, Jack E; Hamann, Tanner R; Dai, Jiaqi; Hitz, Gregory T; Hu, Liangbing; Wachsman, Eric D

    2018-05-01

    Solid-state batteries have many enticing advantages in terms of safety and stability, but the solid electrolytes upon which these batteries are based typically lead to high cell resistance. Both components of the resistance (interfacial, due to poor contact with electrolytes, and bulk, due to a thick electrolyte) are a result of the rudimentary manufacturing capabilities that exist for solid-state electrolytes. In general, solid electrolytes are studied as flat pellets with planar interfaces, which minimizes interfacial contact area. Here, multiple ink formulations are developed that enable 3D printing of unique solid electrolyte microstructures with varying properties. These inks are used to 3D-print a variety of patterns, which are then sintered to reveal thin, nonplanar, intricate architectures composed only of Li 7 La 3 Zr 2 O 12 solid electrolyte. Using these 3D-printing ink formulations to further study and optimize electrolyte structure could lead to solid-state batteries with dramatically lower full cell resistance and higher energy and power density. In addition, the reported ink compositions could be used as a model recipe for other solid electrolyte or ceramic inks, perhaps enabling 3D printing in related fields. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Chapter 6. Operation of electrolytic cell in standard operating practices

    International Nuclear Information System (INIS)

    Yanko, E.A.; Kabirov, Sh.O.; Safiev, Kh.; Azizov, B.S.; Mirpochaev, Kh.A.

    2011-01-01

    This chapter is devoted to operation of electrolytic cell in standard operating practices. Therefore, the electrolyte temperature, the composition of electrolyte, including the level of metals was considered. The regulation of electrolyte composition by liquidus temperature and electrolyte overheating was studied. Damping of anode effects was studied as well. Maintenance of electrolytic cells was described. Heat and energy balances of aluminium electrolytic cells were considered.

  5. Diagnostic value of soluble CD163 serum levels in patients suspected of meningitis: comparison with CRP and procalcitonin

    DEFF Research Database (Denmark)

    Knudsen, Troels Bygum; Larsen, Klaus; Kristiansen, Thomas Birk

    2007-01-01

    CD163. However, sCD163 may be helpful in rapid identification of patients with systemic bacterial infection. If used as an adjunct to lumbar puncture, PCT and CRP had very high diagnostic accuracy for distinguishing between bacterial and viral infection in patients with spinal fluid pleocytosis. However......-operating characteristic AUCs (areas under curves). Patients were classified by 2 sets of diagnostic criteria into: A) purulent meningitis, serous meningitis or non-meningitis, and B) systemic bacterial infection, local bacterial infection or non-bacterial disease. An elevated serum level of sCD163 was the most specific......The aim of the study was to evaluate and compare the diagnostic value of sCD163 serum levels with CRP and PCT in meningitis and bacterial infection. An observational cohort study was conducted between February 2001 and February 2005. The study population comprised 55 patients suspected...

  6. Method of electrolytically decontaminating of radioactive metal wastes

    International Nuclear Information System (INIS)

    Oonuma, Tsutomu; Tanaka, Akio; Yamadera, Toshio.

    1985-01-01

    Purpose: To significantly reduce the volume of secondary wastes by separating from electrolytes metal ions containing radioactive metal ions dissolved therein in the form of elemental metals of a reduced volume with ease, as well as regenerating the electrolytes for re-use. Method: Contaminated portions at the surface of the radioactive metal wastes are dissolved in electrolytes and, when the metal ion concentration in the electrolytes reaches a predetermined level, the electrolytes are introduced to an acid recovery step and an electrodeposition step. The recovered acid is re-used as the electrolytes, while dissolved metal ions containing radioactive metal ions are deposited as elemental metals in the electrodeposition step. The electrolytes usable herein include those acids easily forming stable complex compounds with the metals or those not forming hydroxides of the contaminated metals. Combination of sodium sulfate and sulfuric acid, sodium chloride and hydrochloride or the like is preferred. (Kamimura, M.)

  7. Study on the diagnostic value of combined determination of serum CA125, CA199 and SIL-2R levels in patients with endometriosis

    International Nuclear Information System (INIS)

    Yang Jingxiu; Shi Shaohong; Wang Yuping; Xie Xueqin; Qin Jibao

    2005-01-01

    Objective: To investigate the diagnostic values of combined determination of serum CA125, CA199 and SIL-2R levels in patients with endometriosis. Methods: Serum CA125, CA199 were measured with RIA and SIL-2R levels with ELISA in 54 patients with endometriosis and 35 controls. Results: The serum levels of CA125, CA199 and SIL-2R in patients with endometriosis were significantly higher than those in controls (P<0.01). The sensitivity and speciality of CA125 for endometriosis was 70.2% and 80.4% respectively, the sensitivity and speciality of CA199 for endometriosis was 62.4% and 71.8% respectively, the sensitivity and speciality of SIL-2R was 89.5% and 60.2% respectively. The sensitivity of the combined determination of CA125, CA199 and SIL-2R for endometriosis was 86.8% being significantly higher than that of CA125 and CA199 respectively. Conclusion: Combined determination of the serum CA125, CA199 and SIL-2R levels in serum can increase the diagnostic sensitivity for endometriosis. (authors)

  8. Rebalancing electrolytes in redox flow battery systems

    Science.gov (United States)

    Chang, On Kok; Pham, Ai Quoc

    2014-12-23

    Embodiments of redox flow battery rebalancing systems include a system for reacting an unbalanced flow battery electrolyte with a rebalance electrolyte in a first reaction cell. In some embodiments, the rebalance electrolyte may contain ferrous iron (Fe.sup.2+) which may be oxidized to ferric iron (Fe.sup.3+) in the first reaction cell. The reducing ability of the rebalance reactant may be restored in a second rebalance cell that is configured to reduce the ferric iron in the rebalance electrolyte back into ferrous iron through a reaction with metallic iron.

  9. Clinical value of determination of changes of serum Gas, IL-2, IL-10 and IL-18 levels after transfusion of Red blood cells in patients with peptic ulcer

    International Nuclear Information System (INIS)

    Liu Tingting; Li Xinghua

    2011-01-01

    Objective: To investigation the changes of serum Gas, IL-2, IL-10 and IL-18 contents after transfusion of red blood cells in patients with peptic ulcer. Methods: Serum Gas, IL-2, IL-10 (with RIA), serum IL-18 (with ELISA) levels were measured in 31 patients with peptic ulcer and 35 controls. Results: Before transfusion,the serum IL-2 level in the patients was significantly lower than that in controls (P 0.05). Conclusion: Detection of serum Gas, IL-2, IL-10 and IL-18 levels is clinically useful for monitoring progress and favourable prognosis of patients with peptic ulcer possess important clinical value. (authors)

  10. Serum cortisol values, superior vena cava flow and illness severity scores in very low birth weight infants.

    LENUS (Irish Health Repository)

    Miletin, J

    2012-02-01

    OBJECTIVE: Recent evidence suggests that high cortisol concentrations are associated with increased morbidity and mortality in very low birth weight (VLBW) infants. Neonatal illness severity and mortality risk scores are reliable in predicting morbidity and mortality. The objectives were (i) to assess the correlation between serum cortisol levels and clinical assessment of multi-organ dysfunction\\/illness severity scores (CRIB II, SNAPPE-II and neonatal multiple organ dysfunction score (NEOMOD)) in first 24 h in VLBW infants and (ii) to assess the relationship between surrogates of end organ blood flow and serum cortisol levels. STUDY DESIGN: A prospective observational cohort study. Neonates with birth weight <1500 g were eligible for enrollment. Echocardiography evaluation of superior vena cava (SVC) flow was carried out in the first 24 h life. Cortisol levels were measured simultaneously and appropriate clinical scores were calculated. RESULT: A total of 54 VLBW neonates were enrolled following parental consent. Two patients were excluded because of congenital malformations. In 14 babies the cortisol value was not simultaneously obtained. The mean birth weight was 1.08 kg, mean gestational age was 27.8 weeks. There was a significant correlation between cortisol and NEOMOD score (P=0.006). There was no correlation between cortisol and CRIB II score (P=0.34), SVC flow (P=0.49) and mean arterial blood pressure respectively (P=0.35). CONCLUSION: There was no correlation between SVC flow and cortisol values or between cortisol and mean blood pressure values. There was a significant correlation between cortisol levels and neonatal organ dysfunction score evaluated suggesting that stressed VLBW infants do mount a cortisol response.

  11. Fuel cell assembly with electrolyte transport

    Science.gov (United States)

    Chi, Chang V.

    1983-01-01

    A fuel cell assembly wherein electrolyte for filling the fuel cell matrix is carried via a transport system comprising a first passage means for conveying electrolyte through a first plate and communicating with a groove in a second plate at a first point, the first and second plates together sandwiching the matrix, and second passage means acting to carry electrolyte exclusively through the second plate and communicating with the groove at a second point exclusive of the first point.

  12. Value of the Serum Thyroglobulin Level Alteration at the First High Dose Radioiodine Treatment in Patients with Differentiated Thyroid Carcinoma

    International Nuclear Information System (INIS)

    Nam, Hyun Yeol; Kim, In Joo; Kim, Yong Ki; Kim, Seong Jang; Jun, Sung Min; Kim, Bum Soo

    2009-01-01

    The purpose of this study was to evaluate if short-term serum thyroglobulin (Tg) elevation after radioiodine administration can predict successful radioiodine remnant ablation (RRA) and whether comparable RRA effectiveness is exhibited between a group administered with recombinant human thyrotropin (rhTSH) and a group experiencing thyroid hormone withdrawal (THW), in preparation for RRA. A retrospective chart review was performed on 39 patients in the rhTSH group and 46 patients in the THW group. They were treated for differentiated thyroid carcinoma by total or near total thyroidectomy, and referred for RRA between 2003 and 2006 (the rhTSH group) and between January and June of 2006 (the THW group). They were assessed for serum Tg levels just before I-131 administration (TgD0), reassessed 9 days later (TgD9), and again 6-12 months later. RRA was successful in 64 (37 from the THW group and 27 from the rhTSH group) of the total 85 patients. The success rates of RRA had no statistically significant differences between the two groups. In both groups, TgD9/TgD0 values were significantly higher in the RRA success group (the rhTSH group; P=0.03, the THW group; P=0.04). By combining cutoff values of TgD0 and TgD9/TgD0, the successful RRA value was determined to be 96.7% (29/30) with TgD0≤5.28 ng/mL and TgD9/TgD0>4.37 in both groups (the rhTSH group; 100% (16/16), the THW group; 92.9% (13/14)). Using logistic multivariate analysis, only TgD0 was independently associated with successful RRA. We may predict successful ablation by evaluating short-term serum Tg elevation after I-131 administration for RRA, in both rhTSH and THW patients

  13. Chemical Passivation of Li(exp +)-Conducting Solid Electrolytes

    Science.gov (United States)

    West, William; Whitacre, Jay; Lim, James

    2008-01-01

    Plates of a solid electrolyte that exhibits high conductivity for positive lithium ions can now be passivated to prevent them from reacting with metallic lithium. Such passivation could enable the construction and operation of high-performance, long-life lithium-based rechargeable electrochemical cells containing metallic lithium anodes. The advantage of this approach, in comparison with a possible alternative approach utilizing lithium-ion graphitic anodes, is that metallic lithium anodes could afford significantly greater energy-storage densities. A major impediment to the development of such cells has been the fact that the available solid electrolytes having the requisite high Li(exp +)-ion conductivity are too highly chemically reactive with metallic lithium to be useful, while those solid electrolytes that do not react excessively with metallic lithium have conductivities too low to be useful. The present passivation method exploits the best features of both extremes of the solid-electrolyte spectrum. The basic idea is to coat a higher-conductivity, higher-reactivity solid electrolyte with a lower-conductivity, lower-reactivity solid electrolyte. One can then safely deposit metallic lithium in contact with the lower-reactivity solid electrolyte without incurring the undesired chemical reactions. The thickness of the lower-reactivity electrolyte must be great enough to afford the desired passivation but not so great as to contribute excessively to the electrical resistance of the cell. The feasibility of this method was demonstrated in experiments on plates of a commercial high-performance solid Li(exp +)- conducting electrolyte. Lithium phosphorous oxynitride (LiPON) was the solid electrolyte used for passivation. LiPON-coated solid-electrolyte plates were found to support electrochemical plating and stripping of Li metal. The electrical resistance contributed by the LiPON layers were found to be small relative to overall cell impedances.

  14. Fire-extinguishing organic electrolytes for safe batteries

    Science.gov (United States)

    Wang, Jianhui; Yamada, Yuki; Sodeyama, Keitaro; Watanabe, Eriko; Takada, Koji; Tateyama, Yoshitaka; Yamada, Atsuo

    2018-01-01

    Severe safety concerns are impeding the large-scale employment of lithium/sodium batteries. Conventional electrolytes are highly flammable and volatile, which may cause catastrophic fires or explosions. Efforts to introduce flame-retardant solvents into the electrolytes have generally resulted in compromised battery performance because those solvents do not suitably passivate carbonaceous anodes. Here we report a salt-concentrated electrolyte design to resolve this dilemma via the spontaneous formation of a robust inorganic passivation film on the anode. We demonstrate that a concentrated electrolyte using a salt and a popular flame-retardant solvent (trimethyl phosphate), without any additives or soft binders, allows stable charge-discharge cycling of both hard-carbon and graphite anodes for more than 1,000 cycles (over one year) with negligible degradation; this performance is comparable or superior to that of conventional flammable carbonate electrolytes. The unusual passivation character of the concentrated electrolyte coupled with its fire-extinguishing property contributes to developing safe and long-lasting batteries, unlocking the limit toward development of much higher energy-density batteries.

  15. Nanoscale Organic Hybrid Electrolytes

    KAUST Repository

    Nugent, Jennifer L.

    2010-08-20

    Nanoscale organic hybrid electrolytes are composed of organic-inorganic hybrid nanostructures, each with a metal oxide or metallic nanoparticle core densely grafted with an ion-conducting polyethylene glycol corona - doped with lithium salt. These materials form novel solvent-free hybrid electrolytes that are particle-rich, soft glasses at room temperature; yet manifest high ionic conductivity and good electrochemical stability above 5V. © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Nanoscale Organic Hybrid Electrolytes

    KAUST Repository

    Nugent, Jennifer L.; Moganty, Surya S.; Archer, Lynden A.

    2010-01-01

    Nanoscale organic hybrid electrolytes are composed of organic-inorganic hybrid nanostructures, each with a metal oxide or metallic nanoparticle core densely grafted with an ion-conducting polyethylene glycol corona - doped with lithium salt. These materials form novel solvent-free hybrid electrolytes that are particle-rich, soft glasses at room temperature; yet manifest high ionic conductivity and good electrochemical stability above 5V. © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Recent results on aqueous electrolyte cells

    KAUST Repository

    Wessells, Colin; Huggins, Robert A.; Cui, Yi

    2011-01-01

    The improved safety of aqueous electrolytes makes aqueous lithium-ion batteries an attractive alternative to commercial cells utilizing flammable and expensive organic electrolytes. Two important issues relating to their use have been addressed

  18. The Prognostic Value of Serum Biomarkers in Localized Bone Sarcoma

    DEFF Research Database (Denmark)

    Aggerholm-Pedersen, Ninna; Maretty-Kongstad, Katja; Keller, Johnny

    2016-01-01

    sarcoma were included. Of these patients, 63 were diagnosed with chondrosarcoma and 109 patients with Ewing/osteosarcoma. The median age was 55 years for chondrosarcoma and 19 years for Ewing/osteosarcoma patients. The overall 5-year mortality was 31% [95% confidence interval (CI): 21-44] and 41% (95% CI......OBJECTIVE: Certain biomarkers such as the C-reactive protein, serum albumin, and the neutrophils to lymphocyte ratio are of prognostic significance regarding survival in different types of cancers. Data from sarcoma patients are sparse and mainly derived from soft tissue sarcoma and/or metastatic...... with localized bone sarcomas and to adjust for potential confounders. MATERIAL AND METHODS: All patients diagnosed with localized intermediate and high-grade bone sarcoma during 1994 to 2008 were extracted from the Aarhus Sarcoma Registry. The serum levels of albumin, C-reactive protein, hemoglobin, neutrophils...

  19. Diagnostic values of serum tumor markers Cyfra21-1, SCCAg, ferritin, CEA, CA19-9, and AFP in oral/oropharyngeal squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Yuan CS

    2016-06-01

    Full Text Available Chuanshu Yuan, Kai Yang, Hong Tang, Dan Chen Department of Oral and Maxillofacial Surgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, People’s Republic of China Background: At present, the research on serum tumor markers in the early diagnosis of malignant tumors has aroused widespread concern. The aim of this study was to investigate the diagnostic values of serum tumor markers cytokeratin 19 fragment (Cyfra21-1, squamous cell carcinoma antigen (SCCAg, ferritin, carcinoembryonic antigen (CEA, carbohydrate antigen 19-9 (CA19-9, and α-fetoprotein (AFP for patients with oral/oropharyngeal squamous carcinoma (OSCC/OPSCC. Methods: One hundred and sixty-nine cases of patients with OSCC/OPSCC as the experimental group, 86 cases of oral benign tumor patients as the control group, and 30 cases of healthy people as the normal control group were studied. The levels of serum Cyfra21-1, SCCAg, ferritin, CEA, CA19-9, and AFP were measured using electrochemiluminescence immunoassay. Results: The levels of serum Cyfra21-1, SCCAg, ferritin, and CEA in patients with OSCC/OPSCC were significantly higher than those of benign tumor and healthy control group (P<0.05. The levels of CA19-9 and AFP showed no significant difference between patients with OSCC/OPSCC, benign tumor, and healthy group (P>0.05. The level of serum Cyfra21-1 in patients with early OSCC/OPSCC (stage I + II was significantly higher than that of benign tumor and healthy control group (P<0.05. However, the levels of serum SCCAg, ferritin, CEA, CA19-9, and AFP showed no significant difference between patients with early OSCC/OPSCC, benign tumor, and healthy control group (P>0.05. The levels of serum Cyfra21-1, SCCAg, ferritin, and CEA in the middle-late stage of patients with OSCC/OPSCC (stage III + IV were significantly higher than those of patients with the early OSCC/OPSCC, benign tumor, and healthy control group (P<0.05. The diagnostic cutoff levels of Cyfra21

  20. The conductivity and stability of polymer composite solid electrolyte upon addition of graphene

    Science.gov (United States)

    Hamid, Farzana Abd.; Salleh, Fauzani Md.; Mohamed, Nor Sabirin

    2017-12-01

    The effect of graphene composition on the conductivity and stability of polymer composite solid electrolyte was studied. These polymer composite solid electrolytes were synthesized by sol gel method and prepared via the solution-casting technique. The compositions of graphene were varied between 10 wt% to 70 wt%. The changes in the functional group of polymer composite after the addition of graphene were characterized by Fourier Transform InfraRed spectroscopy. Electrochemical impedance spectroscopy was conducted at ambient temperature in the frequency range of 10 Hz to 1 MHz to study the conductivity of the polymer composite. The highest conductivity was obtained at 60 wt% graphene with the value of 2.85×10-4 Scm-1. Sample without the addition of graphene showed the lowest conductivity value of 1.77×10-7 Scm-1 and acts as an insulator. The high conductivity at 60 wt% graphene loading is related to dehydration of cellulose. This is supported by the FTIR spectrum where the absorption peaks of C-O stretching vibrations of polymer composite is weakened and the hydroxyl group is slightly shifted compared to the FTIR spectrum without the addition of graphene. Linear sweep voltammetry results demonstrated that the polymer composite solid electrolyte exhibited electrochemical stability up to 3.2 V.

  1. The buffer effect in neutral electrolyte supercapacitors

    DEFF Research Database (Denmark)

    Thrane Vindt, Steffen; Skou, Eivind M.

    2016-01-01

    The observation that double-layer capacitors based on neutral aqueous electrolytes can have significantly wider usable potential windows than those based on acidic or alkaline electrolytes is studied. This effect is explained by a local pH change taking place at the electrode surfaces, leading...... potassium nitrate as the electrolyte and potassium phosphates as the buffer system....

  2. Recovery of mercury from mercury compounds via electrolytic methods

    Science.gov (United States)

    Grossman, Mark W.; George, William A.

    1988-01-01

    A process for electrolytically recovering mercury from mercury compounds is provided. In one embodiment, Hg is recovered from Hg.sub.2 Cl.sub.2 employing as the electrolyte solution a mixture of HCl and H.sub.2 O. In another embodiment, Hg is electrolytically recovered from HgO wherein the electrolyte solution is comprised of glacial acetic acid and H.sub.2 O. Also provided is an apparatus for producing isotopically enriched mercury compounds in a reactor and then transporting the dissolved compounds into an electrolytic cell where mercury ions are electrolytically reduced and elemental mercury recovered from the mercury compounds.

  3. Free insulin-like growth factor I serum levels in 1430 healthy children and adults, and its diagnostic value in patients suspected of growth hormone deficiency

    DEFF Research Database (Denmark)

    Juul, A; Holm, K; Kastrup, K W

    1997-01-01

    fraction of the total IGF-I circulates in its free form, which is believed to be the biologically active form. However, our knowledge of the clinical or physiological value of determination of free IGF-I in serum is limited at present. In adults, the diagnostic value of total IGF-I and IGFBP-3......, commercially available immunoradiometric assay (Diagnostic Systems Laboratories) to establish valid normative data for this analysis. We studied the diagnostic value of free IGF-I in relation to total IGF-I and IGFBP-3 determinations in adults who were suspected of GHD. A GH provocative test, using oral...... determinations in patients suspected of GHD has only been reported in a few studies, whereas no previous reports on the diagnostic value of free IGF-I levels in adults suspected of GHD exist. Serum levels of free IGF-I were determined in 1430 healthy children, adolescents, and adults by a newly developed...

  4. Free insulin-like growth factor I serum levels in 1430 healthy children and adults, and its diagnostic value in patients suspected of growth hormone deficiency

    DEFF Research Database (Denmark)

    Juul, A; Holm, K; Kastrup, K W

    1997-01-01

    fraction of the total IGF-I circulates in its free form, which is believed to be the biologically active form. However, our knowledge of the clinical or physiological value of determination of free IGF-I in serum is limited at present. In adults, the diagnostic value of total IGF-I and IGFBP-3...... determinations in patients suspected of GHD has only been reported in a few studies, whereas no previous reports on the diagnostic value of free IGF-I levels in adults suspected of GHD exist. Serum levels of free IGF-I were determined in 1430 healthy children, adolescents, and adults by a newly developed......, commercially available immunoradiometric assay (Diagnostic Systems Laboratories) to establish valid normative data for this analysis. We studied the diagnostic value of free IGF-I in relation to total IGF-I and IGFBP-3 determinations in adults who were suspected of GHD. A GH provocative test, using oral...

  5. Method of continuously regenerating decontaminating electrolytic solution

    International Nuclear Information System (INIS)

    Sasaki, Takashi; Kobayashi, Toshio; Wada, Koichi.

    1985-01-01

    Purpose: To continuously recover radioactive metal ions from the electrolytic solution used for the electrolytic decontamination of radioactive equipment and increased with the radioactive dose, as well as regenerate the electrolytic solution to a high concentration acid. Method: A liquid in an auxiliary tank is recycled to a cathode chamber containing water of an electro depositing regeneration tank to render pH = 2 by way of a pH controller and a pH electrode. The electrolytic solution in an electrolytic decontaminating tank is introduced by way of an injection pump to an auxiliary tank and, interlocking therewith, a regenerating solution is introduced from a regenerating solution extracting pump by way of a extraction pipeway to an electrolytic decontaminating tank. Meanwhile, electric current is supplied to the electrode to deposit radioactive metal ions dissolved in the cathode chamber on the capturing electrode. While on the other hand, anions are transferred by way of a partition wall to an anode chamber to regenerate the electrolytic solution to high concentration acid solution. While on the other hand, water is supplied by way of an electromagnetic valve interlocking with the level meter to maintain the level meter constant. This can decrease the generation of the liquid wastes and also reduce the amount of the radioactive secondary wastes. (Horiuchi, T.)

  6. Effect of electrolytes on surface tension and surface adsorption of 1-hexyl-3-methylimidazolium chloride ionic liquid in aqueous solution

    International Nuclear Information System (INIS)

    Ghasemian, Ensieh; Najafi, Mojgan; Rafati, Amir Abbas; Felegari, Zahra

    2010-01-01

    Surface and bulk properties of 1-hexyl-3-methylimidazolium chloride [C 6 mim][Cl] as an ionic liquid (IL) have been investigated by surface tension and electrical conductivity techniques at various temperatures. Results reveal that the ionic liquid behaves as surfactant-like and aggregates in aqueous solution. Critical aggregation concentration (cac) values obtained by conductivity and surface tension measurements are in good agreement with values found in the literature. A series of important and useful adsorption parameters including cac, surface excess concentration (Γ), and minimum surface area per molecule (A min ) at the air + water interface were estimated from surface tension in the presence and absence of different electrolytes. Obtained data show that the surface tension as well as the cac of [C 6 mim][Cl] is reduced by electrolytes. Also, values of surface excess concentration (Γ) show that the IL ions in the presence of electrolyte have much larger affinity to adsorption at the surface and this affinity increased in aqueous electrolyte solution in the order of I - > Br - > Cl - for counter ion of salts that was explained in terms of a larger repulsion of chloride anions from interface to the bromide and iodide anion as well as difference in their excess polarizability.

  7. Investigation of a nanoconfined, ceramic composite, solid polymer electrolyte

    International Nuclear Information System (INIS)

    Jayasekara, Indumini; Poyner, Mark; Teeters, Dale

    2017-01-01

    The challenges for further development of lithium rechargeable batteries are finding electrolyte materials that are safe, have mechanical and thermal stability and have sufficiently high ionic conduction. Polymer electrolytes have many of these advantages, but suffer with low ionic conduction. This study involves the use of anodic aluminum oxide (AAO) membranes having nanochannels filled with polymer electrolyte to make composite solid electrolytes having ionic conductivity several orders of magnitude higher (10 −4 Ω ‐1 cm −1 ) than non-confined polymer. SEM, ac impedance spectroscopy, temperature dependence studies, XRD, ATR- FTIR and DSC studies were done in order to characterize and understand the behavior of nanoconfined polymer electrolytes. The composite polymer electrolyte was found to be more amorphous with polymer chains aligned in the direction of the nanochannels, which is felt to promote ion conduction. The electrolyte systems, confined in nanoporous membranes, can be used as electrolytes for the fabrication of a room temperature all solid state battery.

  8. Gel electrolytes and electrodes

    Science.gov (United States)

    Fleischmann, Sven; Bunte, Christine; Mikhaylik, Yuriy V.; Viner, Veronika G.

    2017-09-05

    Gel electrolytes, especially gel electrolytes for electrochemical cells, are generally described. In some embodiments, the gel electrolyte layers comprise components a) to c). Component a) may be at least one layer of at least one polymer comprising polymerized units of: a1) at least one monomer containing an ethylenically unsaturated unit and an amido group and a2) at least one crosslinker. Component b) may be at least one conducting salt and component c) may be at least one solvent. Electrodes may comprise the components a), d) and e), wherein component a) may be at least one layer of at least one polymer as described herein. Component d) may be at least one electroactive layer and component e) may be at least one ceramic layer. Furthermore, electrochemical cells comprising component a) which may be at least one layer of at least one polymer as described herein, are also provided.

  9. Application value of combined measurement of serum sTn, CA242, CA19-9 and CEA in the diagnosis of gastroenterological neoplasm

    International Nuclear Information System (INIS)

    Zhang Wanzhong; Chen Zhizhou; Fan Zhenfu

    2007-01-01

    To determine the application value of four serum tumor markers sTn, CA242, CA 19-9 and CEA in the diagnosis of gastroenterological neoplasm, the serum sTn, CA242, CA19-9 and CEA in 30 normal adult controls and 60 patients with gastroenterological neoplasm were measured by IRMA. The results showed that the serum sTn, CA242, CA19-9 and CEA levels in patients with gastric carcinoma or colorectal carcinoma were much higher than those in control group (P<0.01). The serum CEA, CA19-9 and CA242 levels in patients with colorectal carcinoma were significantly higher than those in patients with gastric carcinoma (P<0.01), but the serum sTn level in the former was markedly lower (P<0.01) than that in the latter. The sensitivity of tumor marker increased with the progress of clinical stages, with a considerably higher sensitivity for stage IV compared with stage I-II (P<0.01). The combined test of four tumor markers could be more sensitive than single test in detecting gastric carcinoma and colorectal carcinoma (P<0.05). Four tumor markers are useful for diagnosing gastroenterological neoplasm, and the combined measurement of 4 tumor markers could increase the sensitivity of detecting gastric carcinoma. (authors)

  10. The Diagnostic Value of 18F-FDG PET/CT in Association with Serum Tumor Marker Assays in Breast Cancer Recurrence and Metastasis

    Directory of Open Access Journals (Sweden)

    Ying Dong

    2015-01-01

    Full Text Available Background. After initial treatment of breast cancer (BC, monitoring locoregional recurrence and distant metastases is a great clinical challenge. Objective. To evaluate the efficacy of PET/CT in association with serum tumor makers in BC follow-up. Methods. Twenty-six women with a history of modified radical mastectomy were evaluated by 18F-FDG PET/CT. The results of PET/CT were compared with those of conventional imaging techniques (CITs (including mammography, chest radiography, CT, MRI, ultrasound, and bone scintigraphy. Serum tumor markers of CEA, CA 125, and CA 15-3 in the BC patients were also analyzed in association with the results of PET/CT. Results. Compared with CITs, PET/CT was more sensitive to detect the malignant foci and had better patient-based sensitivity and specificity. The mean CA 15-3 serum level was significantly higher in the confirmed positive patients of PET/CT results than in the confirmed negative ones, while there were no significant differences in the serum levels of CEA and CA 125 of both groups. Conclusion. PET/CT is a highly efficient tool for BC follow-up compared with CITs. The high serum levels of CA 15-3 in confirmed positive PET/CT patients indicated the clinical value of CA 15-3 in BC follow-up.

  11. Establishment of a serum IgG4 cut-off value for the differential diagnosis of IgG4-related disease in Chinese population.

    Science.gov (United States)

    Li, Ping; Chen, Hua; Deng, Chuiwen; Wu, Ziyan; Lin, Wei; Zeng, Xiaofeng; Zhang, Wen; Zhang, Fengchun; Li, Yongzhe

    2016-07-01

    This study was performed to better know diagnosis associated with serum IgG4 concentration, and to explore the possibility for development of a serum IgG4 for IgG4-related disease (IgG4-RD) in Chinese populations. We studied retrospectively 497 IgG4 serum subclass measurements from Peking Union Medical College Hospital during the four-year period, including 242 IgG4-RD, 130 other diseases and 125 healthy individuals. Serum IgG4 concentrations were significantly higher in IgG4-RD than in other pathologies (1662.9 ± 3760.9 mg/L, p IgG4 level between other pathologies group and healthy individuals (p = 0.075). Among the 242 IgG4-RD patients analyzed, serum IgG4 concentrations were normal in 46 patients (19.0%). We found 32 patients (24.6%) with elevated serum IgG4 levels among the 130 patients who suffered from other pathologies. There were seven (5.6%) with serum IgG4 over 1350 mg/L in healthy individuals. The ROC curve analysis revealed that the optimal sensitivity and specificity were 80.0% and 88.2%, respectively, at the concentration of 1575 mg/L for Chinese patients. Our study demonstrated that serum IgG4 elevation was not specific of IgG4-RD. Further studies are needed to define the sensibility and specificity of IgG4 values for the diagnosis of IgG4-RD.

  12. Electrochemical impedance spectroscopy study of the metal hydride alloy/electrolyte junction

    International Nuclear Information System (INIS)

    Khaldi, Chokri; Mathlouthi, Hamadi; Lamloumi, Jilani

    2009-01-01

    The behaviour of the LaNi 3.55 Mn 0.4 Al 0.3 Co 0.75 alloy, used as a negative electrode in the Ni-MH batteries, was studied by the electrochemical impedance spectroscopy (EIS), measured at different potentials. The modeling of the EIS spectra allows us to model the interface electrolyte/Ni-MH electrode by a succession of interfaces electrolyte/corrosion film/alloy particles. The various processes and the physics parameters of each interface are discussed and evaluated. When the potential shifts to more negative values, two reactions are in competition: the hydrogen molecular evolution and the hydrogen atomic absorption. The hydrogen diffuses in the bulk of the alloy and the diffusion is not the limiting factor for the hydrogen absorption.

  13. Assessment of the potential diagnostic value of serum p53 antibody for cancer: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Jun Zhang

    Full Text Available BACKGROUND: Mutant p53 protein over-expression has been reported to induce serum antibodies against p53. We assessed the diagnostic precision of serum p53 (s-p53 antibodies for diagnosis of cancer patients and compared the positive rates of the s-p53 antibody in different types of cancers. METHODS: We systematically searched PubMed and Embase, through May 31, 2012. Studies were assessed for quality using QUADAS (quality assessment of studies of diagnostic accuracy. The positive likelihood ratio (PLR and negative likelihood ratio (NLR were pooled separately and compared with overall accuracy measures using diagnostic odds ratios (DORs and Area under the curve(AUC. Meta regression and subgroup analyses were done, and heterogeneity and publication bias were assessed. RESULTS: Of 1089 studies initially identified, 100 eligible studies with 23 different types of tumor met the inclusion criteria for the meta-analysis (cases = 15953, controls = 8694. However, we could conduct independent meta analysis on only 13 of 36 types of tumors. Approximately 56% (56/100 of the included studies were of high quality (QUADAS score≥8. The summary estimates for quantitative analysis of serum p53 antibody in the diagnosis of cancers were: PLR 5.75 (95% CI: 4.60-7.19, NLR 0.81 (95%CI: 0.79-0.83 and DOR 7.56 (95% CI: 6.02-9.50. However, for the 13 types of cancers on which meta-analysis was conducted, the ranges for PLR (2.33-11.05, NLR (0.74-0.97, DOR (2.86-13.80, AUC(0.29-0.81, and positive rate (4.47%-28.36% indicated significant heterogeneity. We found that breast, colorectal, esophageal, gastric, hepatic, lymphoma, lung and ovarian cancer had relatively reasonable diagnostic accuracy. The remaining results of the five types of cancers suggested that s-p53 antibody had limited value. CONCLUSIONS: The current evidence suggests that s-p53 antibody has potential diagnostic value for cancer, especially for breast, colorectal, esophageal, gastric, hepatic

  14. Alaska Steller sea lion pups blood serum chemistry and hematology values measured from 1998-06-01 to 2011-07-15 (NCEI Accession 0137994)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data were used for an analysis of Steller sea lion pup health and condition by Lander et al. (2013). Serum chemistry and hematological values were measured by...

  15. Relationship Between the Serum Leptin and Children with Malnutrition

    International Nuclear Information System (INIS)

    Xu Jixun

    2010-01-01

    To investigate the relationship between the serum leptin and the children with malnutrition, the serum leptin levels in 50 malnourished children and 50 normal children were determined by RIA. The results showed that the serum leptin levels in children with malnutrition were significantly lower than that in control group (P<0.05). The serum leptin levels in children with malnutrition were positively correlated with body mass index values (r= 0.650, P<0.05), and positively correlated with serum albumin values (r= 0.740,P<0.05). The serum leptin levels in female children were higher than that in men children. The leptin may involve in the regulation of the body nutritional status of children. The serum leptin level may be correlated with the degree of child malnutrition and may be used as a laboratory indicator for the diagnosis of child malnutrition. (authors)

  16. Role of electrolyte composition on structural, morphological and in-vitro biological properties of plasma electrolytic oxidation films formed on zirconium

    International Nuclear Information System (INIS)

    M, Sandhyarani; T, Prasadrao; N, Rameshbabu

    2014-01-01

    Highlights: • Uniform oxide films were formed on zirconium by plasma electrolytic oxidation. • Silicate in electrolyte alter the growth of m-ZrO 2 from (1 ¯ 11) to (2 0 0) orientation. • Addition of KOH to electrolyte improved the corrosion resistance of oxide films. • Silicon incorporated oxide films showed higher surface roughness and wettability. • Human osteosarcoma cells were strongly adhered and spreaded on all the oxide films. - Abstract: Development of oxide films on metallic implants with a good combination of corrosion resistance, bioactivity and cell adhesion can greatly improve its biocompatibility and functionality. Thus, the present work is aimed to fabricate oxide films on metallic Zr by plasma electrolytic oxidation (PEO) in methodically varied concentrations of phosphate, silicate and KOH based electrolyte systems using a pulsed DC power source. The oxide films fabricated on Zr are characterized for its phase composition, surface morphology, chemical composition, roughness, wettability, surface energy, corrosion resistance, apatite forming ability and osteoblast cell adhesion. Uniform films with thickness varying from 6 to 11 μm are formed. XRD patterns of all the PEO films showed the predominance of monoclinic zirconia phase. The film formed in phosphate + KOH electrolyte showed superior corrosion resistance, which can be ascribed to its pore free morphology. The films formed in silicate electrolyte showed higher apatite forming ability with good cell adhesion and spreading over its surface which is attributed to its superior surface roughness and wettability characteristics. Among the five different electrolyte systems employed in the present study, the PEO film formed in an electrolyte system with phosphate + silicate + KOH showed optimum corrosion resistance, apatite forming ability and biocompatibility

  17. Final report on CCQM-K80: Comparison of value-assigned CRMs and PT materials: Creatinine in human serum

    Science.gov (United States)

    Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    The 2009 CCQM-K80 'Comparison of value-assigned CRMs and PT materials: creatinine in human serum' is the first in a series of key comparisons directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes. CCQM-K80 compared the assigned serum creatinine values of certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Six NMIs submitted 17 CRM materials for evaluation, all intended for sale to customers. These materials represent nearly all of the higher-order CRMs then available for this clinically important measurand. The certified creatinine mass fraction in the materials ranged from 3 mg/kg to 57 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analyst using isotope dilution liquid chromatography-mass spectrometry. The instrumental repeatability imprecision, expressed as a percent relative standard deviation, was 1.2%. Given the number of materials and the time required for each analysis, the measurements were made in two measurement campaigns ('runs'). In both campaigns, replicate analyses (two injections of one preparation separated in time) were made on each of two or three independently prepared aliquots from one randomly selected unit of each of the 17 materials. The mean value, between-campaign, between-aliquot and between-replicate variance components, standard uncertainty of the mean value, and the number of degrees of freedom associated with the standard uncertainty were estimated using a linear mixed model. Since several of the uncertainties estimated using this traditional frequentist approach were associated with a single degree of freedom, Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals, U95. Uncertainty-weighted generalized distance

  18. Prognostic value of serum Epstein-Barr virus antibodies in patients with nasopharyngeal carcinoma and undetectable pretreatment Epstein-Barr virus DNA.

    Science.gov (United States)

    Yao, Ji-Jin; Lin, Li; Jin, Ya-Nan; Wang, Si-Yang; Zhang, Wang-Jian; Zhang, Fan; Zhou, Guan-Qun; Cheng, Zhi-Bin; Qi, Zhen-Yu; Sun, Ying

    2017-08-01

    Epstein-Barr virus (EBV) is closely associated with nasopharyngeal carcinoma (NPC). Serum IgA antibodies against early antigen (EA-IgA) and viral capsid antigen (VCA-IgA) are the most commonly used to screen for NPC in endemic areas. However, the prognostic value of serum EA-IgA and VCA-IgA in patients with NPC is less clear. We hypothesize that serum EA-IgA and VCA-IgA levels have prognostic impact for survival outcomes in NPC patients with undetectable pretreatment EBV (pEBV) DNA. In this series, 334 patients with non-metastatic NPC and undetectable pEBV DNA were included. Serum EA-IgA and VCA-IgA were determined by ELISA. After analysis, serum EA-IgA and VCA-IgA loads correlated positively with T, N, and overall stage (all P 1:120 had significantly inferior 5-year progression-free survival (80.4% vs 89.6%, P = 0.025), distant metastasis-free survival (88.4% vs 94.8%, P = 0.050), and locoregional relapse-free survival (88.4% vs 95.6%, P = 0.023; log-rank test). Multivariable analyses revealed that N stage was the only independent prognostic factor (all P < 0.05), but the VCA-IgA became insignificant. Further analyses revealed that serum VCA-IgA was not an independent prognostic factor in early N (N0-1) or advanced N (N2-3) stage NPC. In summary, although both EA-IgA and VCA-IgA correlate strongly with TNM stage, our analyses do not suggest that these antibodies are prognostic biomarkers in patients with NPC and undetectable pEBV DNA. © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  19. Thrombin-Accelerated Quick Clotting Serum Tubes: An Evaluation with 22 Common Biochemical Analytes

    Directory of Open Access Journals (Sweden)

    Wai-Yoong Ng

    2013-01-01

    Full Text Available Clot activator serum tubes have significantly improved turnaround times for result reporting compared to plain tubes. With increasing workload and service performance expectations confronting clinical laboratories with high-volume testing and with particular emphasis on critical analytes, attention has focussed on preanalytical variables that can be improved. We carried out a field study on the test performance of BD vacutainer rapid serum tubes (RSTs compared to current institutional issued BD vacutainer serum separator tubes (SSTs in its test result comparability, clotting time, and stability on serum storage. Data from the study population (n=160 of patients attending outpatient clinics and healthy subjects showed that results for renal, liver, lipids, cardiac, thyroid, and prostate biochemical markers were comparable between RSTs and SSTs. Clotting times of the RSTs were verified to be quick with a median time of 2.05 min. Analyte stability on serum storage at 4°C showed no statistically significant deterioration except for bicarbonate, electrolytes, and albumin over a period of 4 days. In conclusion, RSTs offered savings in the time required for the clotting process of serum specimens. This should translate to further trimming of the whole process from blood collection to result reporting without too much sacrifice on test accuracy and performance compared to the current widely used SSTs in most clinical laboratories.

  20. Comparison of activity coefficient models for electrolyte systems

    DEFF Research Database (Denmark)

    Lin, Yi; ten Kate, Antoon; Mooijer, Miranda

    2010-01-01

    Three activity coefficient models for electrolyte solutions were evaluated and compared. The activity coefficient models are: The electrolyte NRTL model (ElecNRTL) by Aspentech, the mixed solvent electrolyte model (MSE) by OLI Systems Inc., and the Extended UNIQUAC model from the Technical Univer...

  1. Distribution of electrolytes in a flow battery

    Science.gov (United States)

    Darling, Robert Mason; Smeltz, Andrew; Junker, Sven Tobias; Perry, Michael L.

    2017-12-26

    A method of determining a distribution of electrolytes in a flow battery includes providing a flow battery with a fixed amount of fluid electrolyte having a common electrochemically active specie, a portion of the fluid electrolyte serving as an anolyte and a remainder of the fluid electrolyte serving as a catholyte. An average oxidation state of the common electrochemically active specie is determined in the anolyte and the catholyte and, responsive to the determined average oxidation state, a molar ratio of the common electrochemically active specie between the anolyte and the catholyte is adjusted to increase an energy discharge capacity of the flow battery for the determined average oxidation state.

  2. Thermodynamics and Ionic Conductivity of Block Copolymer Electrolytes

    OpenAIRE

    Wanakule, Nisita Sidra

    2010-01-01

    Solid electrolytes have been a long-standing goal of the battery industry since they have been considered safer than flammable liquid electrolytes and are capable of producing batteries with higher energy densities. The latter can be achieved by using a lithium metal anode, which is unstable against liquid electrolytes. Past attempts at polymer electrolytes for lithium-anode batteries have failed due to the formation of lithium dendrites after repeated cycling. To overcome this problem, we ha...

  3. Toxicity effect of sub-chronic oral administration of class bitters® - a polyherbal formula on serum electrolytes and hematological indices in male Wistar albino rats

    Directory of Open Access Journals (Sweden)

    Kingsley C. Patrick-Iwuanyanwu

    2015-11-01

    Full Text Available The indiscriminate administration of readyto- use herbal formulations has become a major concern due to their potential health risk. The study investigated the effect of class bitters® (CB - a polyherbal formula prepared with Mondia whitei, Khaya senegalensis, Capparis erythrocarpus, Thoningia sanguinea and Xylopia aethiopica on serum electrolytes and hematological parameters in male Wistar albino rats. Two doses (500 and 1000 mg kg–1 of the polyherbal drugs were administered orally to male Wistar albino rats for a period of 9 weeks. The results showed that administration of 500 and 1000 mg kg–1 body weight of CB recorded a marked increase in the levels of sodium and chlorum when compared with control. However, there was a marked reduction in the levels of potassium and hydrogen carbonate. The results of the study also showed a significant (P≤0.05 decrease in the level of hematological parameters such as hemoglobin (Hb, packed cell volume (PCV, red blood cells (RBCs and platelets levels in the male Wistar albino rats, when compared with control. The marked decrease in Hb, PCV, RBCs and platelets concentrations observed in experimental rats in this study suggest that CB may have an adverse effect on erythropoiesis. These observations therefore showed that long-term administration of CB might cause renal disease and anemia.

  4. Measuring oxygen activity in liquid sodium with the use of solid electrolytes

    International Nuclear Information System (INIS)

    Jakes, D.; Skvor, F.

    1976-01-01

    Doped Y 2 O 3 (CaO or MgO up to 20 mol.%) was studied as a possible electrolyte. La 2 O 3 did not prove advantageous. The proposed version of an analyzer is described and the problems of calibration discussed. The reduction of the chemical gradient and the increase in material purity of the electrolytical tube significantly reduced the difference between the theoretical and experimentally obtained emf value, so that measurements may be carried out under these conditions even without calibration. The dependence of log σsub(T) on partial O 2 pressure is given for doped La and Y oxides at a temperature of 700 degC. (M.K.)

  5. Diagnostic Difficulties in Woman with Crohn’s Disease, Ascites, and Elevated Value of Serum CA125 Antigen

    Directory of Open Access Journals (Sweden)

    Maria Kłopocka

    2014-01-01

    Full Text Available Variety of symptoms and atypical clinical course of Crohn’s disease (CD often create the need for additional diagnostic procedures. In the described case of woman with CD, there was a suspicion of coexistence of ovarian cancer. This issue is particularly important in patients treated with immunosuppressants and biological agents. The discussion focused on the usefulness of CA125 (cancer antigen 125, mucin 16 serum level estimation in clinical practice and draws attention to the possible reasons for the increase of its value which is not associated to ovarian cancer.

  6. Electrocardiography and serum potassium before and after hemodialysis sessions

    International Nuclear Information System (INIS)

    Tarif, N.; Al-Wakeel, Jamal Saleh; Sulaimani, F.; Memon, Nawaz Ali; Al-Suwaida, Abdul Kareem; Yamani, H.; Bakhsh, Ahmed Jahangir

    2008-01-01

    This study was undertaken to assess potassium level and electrocardiographic (ECG) changes post hemodialysis and whether fall in potassium level during hemodialysis may potentiate cardiac arrythemia. We studied 21 chronic hemodialysis (HD) patients who had their serum electrolytes measured before and after dialysis session and ECG performed at the same time. The patients included 14 females and 7 males with a mean age of 53.1+-15.6 years and range from 26 to 81 years; 9 (43%) patients were diabetics. All the patients had been on dialysis for a minimum of 6 months each Pre-HD serum potassium levels had no correlation with any ECG parameters except a negative correlation with T wave amplitude r=-0.5, p=0.021. ECG parameters significantly changed post-HD; the T wave amplitude decreased and the R wave amplitude increased. A comparatively higher R wave significantly decreased the T to R wave ratio post dialysis. The QRS duration and QTc interval also increased significantly. The patients with post-HD serum potassium of 3.5 mmol/L had a higher R wave amplitude and a significantly less T to R wave ratio (11.8+-9.7 vs 6.4+-5.1, p=0.045 and 0.4+-0.38 vs 1.0+-0.97, p=0.049, respectively. In patients with serum potassium decrement of >2.0 mmol/L, the T to R wave ratio decreased significantly, 0.32+-0.21 vs 0.85+-0.26, p=0.023; The T wave amplitude decreased more than the rise in R wave. Multiple regression analysis did not reveal any relationship of pre or post HD ECG changes and serum potassium, serum calcium or net change in serum potassium post-HD. We conclude that post-HD serum potassium decrement results in a decrease in T to R wave ratio on ECG; this change may have an arrhythmogenic potential. (author)

  7. Improved Cyclability of Liquid Electrolyte Lithium/Sulfur Batteries by Optimizing Electrolyte/Sulfur Ratio

    Directory of Open Access Journals (Sweden)

    Sheng S. Zhang

    2012-12-01

    Full Text Available A liquid electrolyte lithium/sulfur (Li/S cell is a liquid electrochemical system. In discharge, sulfur is first reduced to highly soluble Li2S8, which dissolves into the organic electrolyte and serves as the liquid cathode. In solution, lithium polysulfide (PS undergoes a series of complicated disproportionations, whose chemical equilibriums vary with the PS concentration and affect the cell’s performance. Since the PS concentration relates to a certain electrolyte/sulfur (E/S ratio, there is an optimized E/S ratio for the cyclability of each Li/S cell system. In this work, we study the optimized E/S ratio by measuring the cycling performance of Li/S cells, and propose an empirical method for determination of the optimized E/S ratio. By employing an electrolyte of 0.25 m LiSO3CF3-0.25 m LiNO3 dissolved in a 1:1 (wt:wt mixture of dimethyl ether (DME and 1,3-dioxolane (DOL in an optimized E/S ratio, we show that the Li/S cell with a cathode containing 72% sulfur and 2 mg cm−2 sulfur loading is able to retain a specific capacity of 780 mAh g−1 after 100 cycles at 0.5 mA cm−2 between 1.7 V and 2.8 V.

  8. Diagnostic value of serum free PSA and the ratio of free to total PSA in the diagnosis of prostate cancer

    International Nuclear Information System (INIS)

    Qiu Ningyan; Zhang Jingxin; Wu Jinchang; Gong Yiming; Li Huiping

    2005-01-01

    In order to evaluate the value of free prostate specific antigen (FPSA) and F/T PSA ratio in differential diagnosis of benign prostate hyperplasia (BPH) from prostate cancer (PC), serum FPSA and TPSA levels were measured in 85 patients with PC, 97 BPH and 89 healthy volunteers by chemiluminescence enzyme immunoassay (CLEIA), and the ratio of F/T PSA was calculated. The results showed that serum FPSA and TPSA levels were increased in healthy volunteers of 41-88 years old and were significantly higher in healthy volunteers of 61-88 years old than that in 20-40 gear old (P 10.0 μg/L were 65.0%, 30.9% and 4.1%, respectively, while they were 5.9%, 20.0% and 74.1% in PC patients (P<0.01). When the TPSA value was between 4.0-10.0 μg/L and the ratio of F/T PSA was at 0.10 and below, the probability of PC was larger(88.9%). But the ratio of F/T PSA was at 0.25 and above, the probability of PC was smaller(6.20%). Serum FPSA and TPSA both increased with age in healthy volunteers of 41-88 years old and were positively correlated with age. There were about 30.9% of BPH and 20.0% of PC patients with overlapping of TPSA level. Our conclusion is that the F/T PSA ratio can significantly enhance the specificity for PC diagnosis, especially when the TPSA is within the diagnostic gray zone. (authors)

  9. Diagnostic value of determination of serum pepsinogen and gastrin levels in patients with peptic ulcer

    International Nuclear Information System (INIS)

    Xiao Zhansen; Li Jingrong; Feng Jiandong; Wang Yuqiong; Fu Xiufeng; Zhang Lanfeng

    2005-01-01

    Objective: To investigate the clinical significance of changes of serum pepsinogen and gastrin levels in patients with gastric/duodenal ulcer. Methods: Serum pepsinogen I (PG I), pepsinogen II (PGII), gastrin levels and PG I/PG II ratio were determined with RIA in 100 controls, 61 patients with duodenal ulcer, 46 patients with gastric ulcer, 66 patients with gastric cancer and 101 patients with chronic gastritis. Results: In patients with peptic ulcer (gastric/duodenal), the serum levels of PG I, PG II and PG I/PG II ratio were significantly higher than those in controls (P<0.001); the serum gastrin levels were also significantly higher than those in controls and patients with chronic gastritis (P<0.001), but lower than those in patients with gastric cancer (P<0.001). Among patients with peptic ulcer, the serum PG I level and PG I/PG II ratio were significantly higher in patients with duodenal ulcer than those in patients with gastric ulcer (P<0.001). Conclusion: Excessive high serum levels of PG I, PG II, gastrin and PG I/PG II ratio were some of the high risk factors for peptic ulcer. Those were useful serum markers for diagnosis and follow-up of the disease. (authors)

  10. Electrolytes for lithium ion batteries

    Science.gov (United States)

    Vaughey, John; Jansen, Andrew N.; Dees, Dennis W.

    2014-08-05

    A family of electrolytes for use in a lithium ion battery. The genus of electrolytes includes ketone-based solvents, such as, 2,4-dimethyl-3-pentanone; 3,3-dimethyl 2-butanone(pinacolone) and 2-butanone. These solvents can be used in combination with non-Lewis Acid salts, such as Li.sub.2[B.sub.12F.sub.12] and LiBOB.

  11. Solid polymer electrolyte lithium batteries

    Science.gov (United States)

    Alamgir, Mohamed; Abraham, Kuzhikalail M.

    1993-01-01

    This invention pertains to Lithium batteries using Li ion (Li.sup.+) conductive solid polymer electrolytes composed of solvates of Li salts immobilized in a solid organic polymer matrix. In particular, this invention relates to Li batteries using solid polymer electrolytes derived by immobilizing solvates formed between a Li salt and an aprotic organic solvent (or mixture of such solvents) in poly(vinyl chloride).

  12. High flash point electrolyte for use in lithium-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Isken, P.; Dippel, C.; Schmitz, R.; Schmitz, R.W.; Kunze, M.; Passerini, S.; Winter, M. [Institute of Physical Chemistry, Westfaelische Wilhelms-University Muenster, Corrensstrasse 28/30, 48149 Muenster (Germany); Lex-Balducci, A., E-mail: a.lex-balducci@uni-muenster.de [Institute of Physical Chemistry, Westfaelische Wilhelms-University Muenster, Corrensstrasse 28/30, 48149 Muenster (Germany)

    2011-09-01

    Highlights: > Substitution of linear carbonates in conventional electrolytes with adiponitrile allows the realization of high flash point electrolytes. > EC:ADN based electrolytes display a higher anodic stability than a conventional electrolyte based on EC:DEC. > Graphite and NCM electrodes used in combination with the EC:ADN based electrolyte display a performance comparable with that of conventional electrolytes. - Abstract: The high flash point solvent adiponitrile (ADN) was investigated as co-solvent with ethylene carbonate (EC) for use as lithium-ion battery electrolyte. The flash point of this solvent mixture was more than 110 deg. C higher than that of conventional electrolyte solutions involving volatile linear carbonate components, such as diethyl carbonate (DEC) or dimethyl carbonate (DMC). The electrolyte based on EC:ADN (1:1 wt) with lithium tetrafluoroborate (LiBF{sub 4}) displayed a conductivity of 2.6 mS cm{sup -1} and no aluminum corrosion. In addition, it showed higher anodic stability on a Pt electrode than the standard electrolyte 1 M lithium hexafluorophosphate (LiPF{sub 6}) in EC:DEC (3:7 wt). Graphite/Li half cells using this electrolyte showed excellent rate capability up to 5C and good cycling stability (more than 98% capacity retention after 50 cycles at 1C). Additionally, the electrolyte was investigated in NCM/Li half cells. The cells were able to reach a capacity of 104 mAh g{sup -1} at 5C and capacity retention of more than 97% after 50 cycles. These results show that an electrolyte with a considerably increased flash point with respect to common electrolyte systems comprising linear carbonates, could be realized without any negative effects on the electrochemical performance in Li-half cells.

  13. Semiconductor electrolyte photovoltaic energy converter

    Science.gov (United States)

    Anderson, W. W.; Anderson, L. B.

    1975-01-01

    Feasibility and practicality of a solar cell consisting of a semiconductor surface in contact with an electrolyte are evaluated. Basic components and processes are detailed for photovoltaic energy conversion at the surface of an n-type semiconductor in contact with an electrolyte which is oxidizing to conduction band electrons. Characteristics of single crystal CdS, GaAs, CdSe, CdTe and thin film CdS in contact with aqueous and methanol based electrolytes are studied and open circuit voltages are measured from Mott-Schottky plots and open circuit photo voltages. Quantum efficiencies for short circuit photo currents of a CdS crystal and a 20 micrometer film are shown together with electrical and photovoltaic properties. Highest photon irradiances are observed with the GaAs cell.

  14. Synthesis of polymer gel electrolyte with high molecular weight poly(methyl methacrylate)-clay nanocomposite

    International Nuclear Information System (INIS)

    Meneghetti, Paulo; Qutubuddin, Syed; Webber, Andrew

    2004-01-01

    Polymer nanocomposite gel electrolytes consisting of high molecular weight poly(methyl methacrylate) PMMA-clay nanocomposite, ethylene carbonate (EC)/propylene carbonate (PC) as plasticizer, and LiClO 4 electrolyte are reported. Montmorillonite clay was ion exchanged with a zwitterionic surfactant (octadecyl dimethyl betaine) and dispersed in methyl methacrylate, which was then polymerized to synthesize PMMA-clay nanocomposites. The nanocomposite was dissolved in a mixture of EC/PC with LiClO 4 , heated and pressed to obtain polymer gel electrolyte. X-ray diffraction (XRD) of the gels indicated intercalated clay structure with d-spacings of 2.85 and 1.40 nm. In the gel containing plasticizer, the clay galleries shrink suggesting intercalation rather than partial exfoliation observed in the PMMA-clay nanocomposite. Ionic conductivity varied slightly and exhibited a maximum value of 8 x 10 -4 S/cm at clay content of 1.5 wt.%. The activation energy was determined by modeling the conductivity with a Vogel-Tamman-Fulcher expression. The clay layers are primarily trapped inside the polymer matrix. Consequently, the polymer does not interact significantly with LiClO 4 electrolyte as shown by FTIR. The presence of the clay increased the glass transition temperature (Tg) of the gel as determined by differential scanning calorimetry. The PMMA nanocomposite gel electrolyte shows a stable lithium interfacial resistance over time, which is a key factor for use in electrochemical applications

  15. Transient current distributions in porous zinc electrodes in KOH electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Liu, M.B.; Yamazaki, Y.; Cook, G.M.; Yao, N.P.

    1981-02-01

    A zero-resistance ammeter circuit with a 10-channel operational amplifier was used to measure the current distribution during a discharge of 10 to 100 mA with simulated zinc porous electrodes in 7.24 M KOH saturated with ZnO. The reaction distribution was found to be highly nonuniform, with 70 to 78% of the charge transfer reaction completed in a depth of 0.01 cm. The high nonuniformity of the initial reaction profile was believed to be due to low conductivity of the electrolyte in the electrode pores. The current distribution changes during passivation of the electrode were experimentally obtained. A mathematical model based upon a macroscope averaging technique was used to predict the time dependence of charge transfer reaction profiles. With mathematical model, current distributions and overpotentials were predicted as a function of time for the segmented zinc electrode discharged at a current of 10 to 100 mA; for these predictions, assumed values of both precipitation rate constants for porous ZnO and diffusion coefficients for hydroxide and zincate ions were used. A gradual decrease in the specific conductivity of the pore electrolyte to 20% of the initial value during discharge yields predictions of current distributions and overpotentials in good agreement with the experimental data. The extent of reduction in the specific conductivity of the pore electrolyte implies a supersaturation of zincate of four times chemical saturation, which was been observed experimentally.At high discharge current (25 to 100 mA), the passivation behavior of the electrode has been simulated. The results of the experiments and mathematical model show that the effective reaction penetration depth is less than 0.02 cm.

  16. [Diagnostic value of baseline serum luteinizing hormone level for central precocious puberty in girls].

    Science.gov (United States)

    Ou-Yang, Li-Xue; Yang, Fan

    2017-07-01

    To evaluate the diagnostic value of baseline serum luteinizing hormone (LH) level for central precocious puberty (CPP) in girls. A total of 279 girls with precocious puberty were subjected to assessment of growth and development, bone age determination, baseline LH test, and follicle-stimulating hormone (FSH) test, gonadotropin-releasing hormone stimulation test, and other related examinations. Of the 279 patients, 175 were diagnosed with CPP and 104 with premature thelarche (PT). The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of baseline LH and FSH levels and their peak levels for CPP, and the correlation between the baseline LH level and the peak LH level was analyzed. The CPP group had significantly higher bone age, baseline LH and FSH levels, peak LH and FSH levels, and ratio of peak LH level to peak FSH level than the PT group (Pbaseline LH level and peak LH level had good diagnostic values for CPP. Among the three bone age subgroups in the CPP group (7.0-9.0 years, 9.0-11.0 years, and >11.0 years), baseline LH level showed the best diagnostic value in the >11.0 years subgroup, with the largest area under the ROC curve. At a baseline LH level of 0.45 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 66.7% and 80% respectively, for the diagnosis of CPP. At a peak LH level of 9.935 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 74.8% and 100% respectively, for the diagnosis of CPP. The baseline LH level was positively correlated with the peak LH level (r=0.440, PBaseline LH level can be used as an primary screening index for the diagnosis of CPP. It has a certain diagnostic value for CPP at different bone ages, and may be used as a monitoring index during the treatment and follow-uP.

  17. CD4 lymphocyte counts and serum p24 antigen of no diagnostic value in monitoring HIV-infected patients with pulmonary symptoms

    DEFF Research Database (Denmark)

    Orholm, M; Nielsen, T L; Nielsen, Jens Ole

    1990-01-01

    The diagnostic value of the CD4 cell counts and the HIV p24 antigen were evaluated in a consecutive series of 105 HIV-infected patients experiencing 128 episodes of pulmonary symptoms which required bronchoscopy. One-third of patients with opportunistic infection (OI) had CD4 counts greater than 0....... In conclusion, the CD4 cell counts and the presence of p24 antigen in serum had a very limited predictive value for the presence of OI in HIV-infected patients with pulmonary symptoms....

  18. New Solid Polymer Electrolytes for Improved Lithium Batteries

    Science.gov (United States)

    Hehemann, David G.

    2002-01-01

    The objective of this work was to identify, synthesize and incorporate into a working prototype, next-generation solid polymer electrolytes, that allow our pre-existing solid-state lithium battery to function better under extreme conditions. We have synthesized polymer electrolytes in which emphasis was placed on the temperature-dependent performance of these candidate electrolytes. This project was designed to produce and integrate novel polymer electrolytes into a lightweight thin-film battery that could easily be scaled up for mass production and adapted to different applications.

  19. Recent results on aqueous electrolyte cells

    Science.gov (United States)

    Wessells, Colin; Huggins, Robert A.; Cui, Yi

    2011-03-01

    The improved safety of aqueous electrolytes makes aqueous lithium-ion batteries an attractive alternative to commercial cells utilizing flammable and expensive organic electrolytes. Two important issues relating to their use have been addressed in this work. One is the extension of the usable voltage range by the incorporation of lithium salts, and the other is the investigation of a useful negative electrode reactant, LiTi2(PO4)3. The electrochemical stability of aqueous lithium salt solutions containing two lithium salts, LiNO3 and Li2SO4, has been characterized using a constant current technique. In both cases, concentrated solutions had effective electrolyte stability windows substantially greater than that of pure water under standard conditions. At an electrolyte leakage current of 10 μA cm-2 between two platinum electrodes in 5 M LiNO3 the cell voltage can reach 2.0 V, whereas with a leakage current of 50 μA cm-2 it can reach 2.3 V. LiTi2(PO4)3 was synthesized using a Pechini method and cycled in pH-neutral Li2SO4. At a reaction potential near the lower limit of electrolyte stability, an initial discharge capacity of 118 mAh g-1 was measured at a C/5 rate, while about 90% of this discharge capacity was retained after 100 cycles. This work demonstrates that it is possible to have useful aqueous electrolyte lithium-ion batteries using the LiTi2(PO4)3 anode with cell voltages of 2 V and above.

  20. Centile values for serum lipids and blood pressure for Asian Indian adolescents

    Directory of Open Access Journals (Sweden)

    Dhingra Vibha

    2005-09-01

    Full Text Available Abstract Background Reference data for plasma lipids and blood pressure are not available for Asian Indian adolescents. This study aimed to develop representative age- and sex- specific percentile reference data for serum lipids [total cholesterol (TC, triglycerides (TG, low density lipoprotein cholesterol (LDL-C, high density lipoprotein cholesterol (HDL-C, non-HDL cholesterol] and blood pressure for urban Asian Indian adolescents aged 14–18 years. The sample consisted of 680 boys and 521 girls aged 14–18 years from the cross-sectional population survey, Epidemiological Study of Adolescents and Young Adults (ESAY for whom the data for serum lipid levels and blood pressure were recorded. Smoothed age- and sex- specific 5th, 10th, 25th, 50th, 75th, 85th, 90th and 95th percentiles where derived using LMS regression. Results Percentile-based reference data for serum lipids and blood pressure are presented for adolescent Asian Indian boys and girls for the first time. Asian Indian adolescents had lower levels of serum TC, LDL-C and HDL-C and higher TG than their counterparts in the USA. Interesting trends in TC and HDL-C levels where observed, which might reflect changes in dietary pattern and physical activity in this age group in India. Conclusion These reference data could be used to identify adolescents with an elevated risk of developing dyslipidemia, hypertension and cardiovascular disorders, to plan and implement preventive policies, and to study temporal trends.

  1. Serum lipid and lipoprotein patterns of Iranian horses.

    Science.gov (United States)

    Asadi, F; Asadian, P; Shahriari, A; Pourkabir, M; Kazemi, A

    2011-12-01

    Patterns of serum biochemical parameters vary among horse breeds. The objective of the present study was to compare serum lipoproteins of Iranian Caspian ponies with those of other horses (Arabs and Thoroughbreds) in the Iranian region. Serum lipoprotein values were determined by agar-agarose gel electrophoresis and measured by scan densitometry. Moreover, serum triglyceride and cholesterol concentrations were determined and the results were analysed by one-way analysis of variance. Serum triglyceride and cholesterol values were 1.13 +/- 0.23 and 2.38 +/- 0.18 mmol/l in Caspian ponies, 1.96 +/- 0.49 and 1.92 +/- 0.25 mmol/l in Arab horses and 1.38 +/- 0.26 and 2.17 +/- 0.53 mmol/l in Thoroughbred horses. The relative percentages of alpha- (72.63 +/- 17.76%) and beta-lipoproteins (29.10 +/- 5.49%) in serum electrophoretic tracings from Caspian ponies were not significantly different from those of other horses (p > 0.05). The lipoprotein phenotype in Caspian ponies may be useful for evaluating metabolic diseases.

  2. Predictive value of serum Inhibin-B levels as an indicator of the presence of testicular spermatozoa in non-obstructive azoospermia

    Directory of Open Access Journals (Sweden)

    Marwan Alhalabi

    2016-12-01

    Full Text Available Introduction: Inhibin-B is glycoproteins of the transforming growth factor-β superfamily, is produced almost exclusively by the Sertoli cells and has been proposed as direct markers of their function and indirect markers of spermatogenesis. Our objective was to evaluate the predictive value of serum Inhibin-B levels as an indicator of the presence of testicular spermatozoa in non-obstructive azoospermia (NOA, compared with other markers such as FSH and testicular volume. Material and methods: A total of 228 patients with idiopathic non-obstructive azoospermia (NOA were recruited in this prospective study. Inhibin-B in serum has been evaluated before sperm retrieval by Enzyme-Linked Immuno-Sorbent Assay (Elisa, in addition to FSH and testosterone. Testicular volume was measured by sonography. Testicular Fine Needle Aspiration (FNA and Testicular Sperm Extraction (TESE were performed for sperm retrieval. The patients were classified according to the presence or absence of Testicular spermatozoa into two groups (I and II respectively. Results: Spermatozoa were retrieved in 87 patients (38.16%, classified as group I and were absent in 141 patients (61.84% classified as group II. Mean serum Inhibin-B ± SD was significantly higher in group I than in group II, 71.77 versus 27.49 respectively (P < 0.001. The odds ratio of Inhibin-B for success of sperm retrieval was 1.0409 (95% CI: 1.0286–1.0533. Serum Inhibin-B demonstrated that the best inhibin-B value threshold for discriminating between successful and failed sperm retrieval was 35 pg/ml, with a sensitivity of 75.86 (95% Confidence interval [CI]: 65.5–84.4 and specificity of 80.85 (CI: 73.4–87.0 for the prediction of the presence of testicular spermatozoa as determined by the receiver operating characteristic (ROC curve analysis and area under curve (AUC. Conclusions: Inhibin-B might be a predictive marker of persistent spermatogenesis in the men with non-obstructive azoospermia.

  3. Predictive and prognostic value of preoperative serum tumor markers is EGFR mutation-specific in resectable non-small-cell lung cancer

    Science.gov (United States)

    Jiang, Richeng; Wang, Xinyue; Li, Kai

    2016-01-01

    Background The predictive and prognostic value of carcinoembryonic antigen (CEA), cytokeratin-19 fragments (Cyfra21-1), squamous cell carcinoma antigen (SCCA) and neuron-specific enolase (NSE) has been investigated in non-small-cell lung cancer (NSCLC) patients. However, few studies have directly focused on the association between these markers and epidermal growth factor receptor (EGFR) mutation status or mutation subtypes. Patients and methods We retrospectively analyzed 1016 patients with stage I-IIIA NSCLC who underwent complete resection between 2008 and 2012. Correlations between serum tumor marker levels and EGFR mutations and survival parameters were analyzed and prognostic factors were identified. Results Cyfra21-1 levels (P = 0.032 for disease-free survival [DFS]; P CEA levels (P CEA (P = 0.005) and clinical stage were predictive factors of DFS, while elevated CEA (P = 0.005) and Cyfra21-1 (P = 0.027) were independent prognostic factors. Conclusion Cyfra21-1 and CEA exhibit different predictive and prognostic values between EGFR-mutated and wild-type adenocarcinomas, as well as between EGFR mutation subtypes. The prognostic impact of preoperative serum tumor markers should be evaluated together with EGFR mutation status. PMID:27072585

  4. Electrochemical corrosion behaviour of plasma electrolytic oxidation coatings on AM50 magnesium alloy formed in silicate and phosphate based electrolytes

    International Nuclear Information System (INIS)

    Liang, J.; Srinivasan, P. Bala; Blawert, C.; Stoermer, M.; Dietzel, W.

    2009-01-01

    PEO coatings were produced on AM50 magnesium alloy by plasma electrolytic oxidation process in silicate and phosphate based electrolytes using a pulsed DC power source. The microstructure and composition of the PEO coatings were analyzed by scanning electron microscopy (SEM) and X-ray Diffraction (XRD). The corrosion resistance of the PEO coatings was evaluated using open circuit potential (OCP) measurements, potentiodynamic polarisation tests and electrochemical impedance spectroscopy (EIS) in 0.1 M NaCl solution. It was found that the electrolyte composition has a significant effect on the coating evolution and on the resulting coating characteristics, such as microstructure, composition, coating thickness, roughness and thus on the corrosion behaviour. The corrosion resistance of the PEO coating formed in silicate electrolyte was found to be superior to that formed in phosphate electrolyte in both the short-term and long-term electrochemical corrosion tests.

  5. Cosolvent electrolytes for electrochemical devices

    Science.gov (United States)

    Wessells, Colin Deane; Firouzi, Ali; Motallebi, Shahrokh; Strohband, Sven

    2018-01-23

    A method for stabilizing electrodes against dissolution and/or hydrolysis including use of cosolvents in liquid electrolyte batteries for three purposes: the extension of the calendar and cycle life time of electrodes that are partially soluble in liquid electrolytes, the purpose of limiting the rate of electrolysis of water into hydrogen and oxygen as a side reaction during battery operation, and for the purpose of cost reduction.

  6. Effect of Mixing Dyes and Solvent in Electrolyte Toward Characterization of Dye Sensitized Solar Cell Using Natural Dyes as The Sensitizer

    Science.gov (United States)

    Puspitasari, Nurrisma; Nurul Amalia, Silviyanti S.; Yudoyono, Gatut; Endarko

    2017-07-01

    Dye Sensitized Solar Cell (DSSC) using natural dyes (chlorophyll, curcumin from turmeric extract, and anthocyanin from mangosteen extract) have been successfully fabricated for determining the effect of variation natural dyes, mixing dyes and acetonitrile in electrolyte toward characterization of DSSC. DSSC consists of five parts namely ITO (Indium Tin Oxide) as a substrate; TiO2 as semiconductor materials; natural dyes as an electron donor; electrolyte as electron transfer; and carbon as a catalyst that can convert light energy into electric energy. Two types of gel electrolyte based on PEG that mixed with liquid electrolyte have utilized for analyzing the lifetime of DSSC. Type I used distilled water as a solvent whilst type II used acetonitrile as a solvent with addition of concentration of KI and iodine. The main purpose of study was to investigate influence of solvent in electrolyte, variation of natural dyes and mixing dyes toward an efficiency that resulted by DSSC. The result showed that electrolyte type II is generally better than type I with efficiency 0,0556 and 0,0456 %, respectively. An efficiency values which resulted from a variation of mixed three natural dyes showed the greatest efficiency compared to mixed two natural dyes and one dye, with an efficiency value can be achieved at 0,0194 % for chlorophyll; 0,111 % for turmeric; 0,0105 % for mangosteen; 0,0244% (mangosteen and chlorophyll); 0,0117 % (turmeric and mangosteen); 0,0158 % (turmeric and chlorophyll); and 0.0566 % (mixed three natural dyes).

  7. Self-association and thermodynamic behavior of etilefrine hydrochloride in aqueous electrolyte solution

    International Nuclear Information System (INIS)

    Elmasry, Manal S.; Hassan, Wafaa S.; Elazazy, Marwa S.

    2014-01-01

    Highlights: • The self-association of etilefrine HCl in aqueous solution has been studied. • Conductivity and 1 H NMR measurements were used to study the self association. • The critical micelle concentrations and the degree of ionizations were calculated. • The effect of different temperatures and NaCl concentrations were studied. • The thermodynamic parameters of self association of etilefrine HCl were evaluated. - Abstract: The self-association (micellization) behavior of etilefrine HCl, an amphiphilic drug, in aqueous electrolyte solution has been investigated as a function of temperature and sodium chloride (NaCl) concentration by conductivity and 1 H NMR measurements. The critical micelle concentration (CMC) was calculated from the inflection in the data obtained from both techniques. The CMC and the degree of ionization (α) values were determined over the temperature range (298.15 to 313.15) K in water and in presence of different concentrations of NaCl. The thermodynamic parameters of micellization for etilefrine HCl i.e. the standard Gibbs free energy change ΔG° m , the standard enthalpy change, ΔH° m , and the standard entropy change, ΔS° m , were evaluated according to the pseudo-phase model. The obtained CMC values, in presence and absence of electrolyte, showed an inverted U-shaped behavior. While the degree of micelle ionization (α) showed a linear response to the increase in temperature in absence of electrolyte, addition of NaCl did not cause a specific response

  8. Preparation of rT3 in human serum ria kit

    International Nuclear Information System (INIS)

    Zhang Peixuan; Han Shiquan; Zhang Liling

    1991-02-01

    A method for the measurement of rT 3 in serum by radioimmunoassay is presented. The double antibody plus polyethylene glycol was used as separating reagent. The method is simple, precise and sensitive. Serum rT 3 values of normal (n = 61) were 47.7 ± 11.34 x 10 -8 g/L (X-bar ± SD). Patients with hyperthyroidism (n = 8) serum rT 3 values were 272.2 ± 91.1 x 10 -8 g/L (X-bar ± SD) and patients with hypothyroidism (n = 2) serum rT 3 values were 11.4 ± 8.3 x 10 -8 g/L (X-bar ± SD). It appears to be a useful diagnostic procedure for thyroid diseases

  9. Corrosion of pure magnesium under thin electrolyte layers

    International Nuclear Information System (INIS)

    Zhang Tao; Chen Chongmu; Shao Yawei; Meng Guozhe; Wang Fuhui; Li Xiaogang; Dong Chaofang

    2008-01-01

    The corrosion behavior of pure magnesium was investigated by means of cathodic polarization curve, electrochemical impedance spectroscopy (EIS) and electrochemical noise (EN) under aerated and deaerated thin electrolyte layers (TEL) with various thicknesses. Based on shot noise theory and stochastic theory, the EN results were quantitatively analyzed by using the Weibull and Gumbel distribution function, respectively. The results show that the cathodic process of pure magnesium under thin electrolyte layer was dominated by hydrogen reduction. With the decreasing of thin electrolyte layer thickness, cathodic process was retarded slightly while the anodic process was inhibited significantly, which indicated that both the cathodic and anodic process were inhibited in the presence of oxygen. The absence of oxygen decreased the corrosion resistance of pure magnesium in case of thin electrolyte layer. The corrosion was more localized under thin electrolyte layer than that in bulk solution. The results also demonstrate that there exist two kinds of effects for thin electrolyte layer on the corrosion behavior of pure magnesium: (1) the rate of pit initiation was evidently retarded compared to that in bulk solution; (2) the probability of pit growth oppositely increased. The corrosion model of pure magnesium under thin electrolyte layer was suggested in the paper

  10. Hydrogel membrane electrolyte for electrochemical capacitors

    Indian Academy of Sciences (India)

    Administrator

    Abstract. Polymer electrolytes are known to possess excellent physicochemical properties that are very useful for electrochemical energy systems. The mobility in polymer electrolytes is understood to be mainly due to the segmental motion of polymer chains and the ion transport is generally restricted to the amorphous ...

  11. Female alcoholics: electrocardiographic changes and associated metabolic and electrolytic disorders

    Directory of Open Access Journals (Sweden)

    Borini Paulo

    2003-01-01

    Full Text Available OBJECTIVE: To identify the electrocardiographic changes and their associations with metabolic and electrolytic changes in female alcoholics. METHODS: The study comprised 44 female alcoholics with no apparent physical disorder. They underwent the following examinations: conventional electrocardiography; serologic tests for syphilis, Chagas' disease, and hepatitis B and C viruses; urinary pregnancy testing; hematimetric analysis; biochemical measurements of albumin, fibrinogen, fasting and postprandial glycemias, lipids, hepatic enzymes, and markers for tissue necrosis and inflammation. RESULTS: Some type of electrocardiographic change was identified in 33 (75% patients. In 17 (38.6% patients, more than one of the following changes were present: prolonged QTc interval in 24 (54.5%, change in ventricular repolarization in 11(25%, left ventricular hypertrophy in 6 (13.6%, sinus bradycardia in 4 (9.1%, sinus tachycardia in 3 (6.8%, and conduction disorder in 3 (6.8%. The patients had elevated mean serum levels of creatine phosphokinase, aspartate aminotransferases, and gamma glutamyl transferase, as well as hypocalcemia and low levels of total cholesterol and LDL-cholesterol. The patients with altered electrocardiograms had a more elevated age, a lower alcohol consumption, hypopotassemia, and significantly elevated levels of triglycerides, postprandial glucose, sodium and gamma glutamyl transferase than those with normal electrocardiograms. The opposite occurred with fasting glycemia, magnesium, and alanine aminotransferase. CONCLUSION: The electrocardiographic changes found were prolonged QTc interval, change in ventricular repolarization, and left ventricular hypertrophy. Patients with normal and abnormal electrocardiograms had different metabolic and electrolytic changes.

  12. Determination of serum IgD radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l.

  13. Organosilicon-Based Electrolytes for Long-Life Lithium Primary Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Fenton, Kyle R. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Nagasubramanian, Ganesan [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Staiger, Chad L. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Pratt, III, Harry D. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Rempe, Susan B. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Leung, Kevin [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Chaudhari, Mangesh I. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Anderson, Travis Mark [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    This report describes advances in electrolytes for lithium primary battery systems. Electrolytes were synthesized that utilize organosilane materials that include anion binding agent functionality. Numerous materials were synthesized and tested in lithium carbon monofluoride battery systems for conductivity, impedance, and capacity. Resulting electrolytes were shown to be completely non-flammable and showed promise as co-solvents for electrolyte systems, due to low dielectric strength.

  14. Zinc polymer electrolytes in battery systems

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, W.P.; Latham, R.J.; Linford, R.G.; Vickers, S.L. (Dept. of Chemistry, School of Applied Sciences, De Montfort Univ., Leicester (United Kingdom))

    1994-06-01

    We have previously reported results of our studies of structure-conductivity relationships for polymer electrolytes of the form PEO[sub n][center dot]ZnX[sub 2]. In this paper we report the results of investigations of battery systems based on these electrolytes. Results will be presented for OCV and discharge curves for loaded cells of the type: Zn/polymer electrolyte/MnO[sub 2]. We are particularly interested in the speciation between oxidation states of manganese as a function of the degree of cell discharge, and have carried out determinations by chemical methods based on polarography. Preliminary studies indicate the presence of Mn[sup II] in cells discharged at various rates. The discharge times for a series of optimised cells show an exponential decrease with increasing load. This is consistent with a low electrolyte conductivity and less than ideal cathode conductivity, which leads to an increased 'front face' reaction with increasing load

  15. Diagnostic value of serum procalcitonin levels in children with meningitis: a comparison with blood leukocyte count and C-reactive protein

    International Nuclear Information System (INIS)

    Ibrahim, K.A.; Wahab, A.A.A.; Ibrahim, A.S.

    2011-01-01

    Objectives: To determine the level of serum procalcitonin, blood leukocyte count (TLC) and C-reactive protein (CRP) in children with bacterial and non bacterial meningitis and document their efficacy in differential diagnosis. Also described are procalcitonin levels variation during treatment. Methods: From March 2005 to February 2008, we evaluated 38 clinically suspected meningitis patients in the paediatric departments, Al-Jedaany Hospital, Jeddah, KSA, for Serum procalcitonin, CRP, TLC and Lumbar punctures and CSF analysis. Patients were classified into bacterial meningitis group I (18) and non bacterial meningitis group II (20). Results: Serum PCT levels were significantly higher in bacterial meningitis (BM) 9 mean 4.8 +- 3.85 ng/ml (2.9-11.6)) compared with non bacterial meningitis (NBM) (mean 0.38 +- 0.25 ng/ml(0.31-0.61)) P< 0.001). Mean of all CSF parameters, TLC (15,000 +- 2,900 cell/ml(BM) and 9,500 +-1,105 cell/ml(NBM))and CRP (20 +- 6.8 mg/l (BM) and 12.5 +-12.0 mg/l(NBM))showed a zone of overlapping between the two groups. There is a positive correlation between serum PCT, TLC and CRP in bacterial and non bacterial meningitis cases but this relation becomes highly significant with bacterial meningitis positive group. Day 3 and day 6 treatment serum PCT was less than on admission levels (P<0.001). Conclusion: PCT can be used in the early diagnosis of bacterial meningitis and may be a useful adjunct in differentiating bacterial and non bacterial meningitis than CRP or TLC and diminishing the value of lumbar puncture performed 48-72 hours after admission to assess treatment efficacy. (author)

  16. Electrolytes: transport properties and non-equilibrium thermodynamics

    International Nuclear Information System (INIS)

    Miller, D.G.

    1980-12-01

    This paper presents a review on the application of non-equilibrium thermodynamics to transport in electrolyte solutions, and some recent experimental work and results for mutual diffusion in electrolyte solutions

  17. An elevated serum alkaline phosphatase level in hepatic metastases of grade 1 and 2 gastrointestinal neuroendocrine tumors is unusual and of prognostic value.

    Science.gov (United States)

    Andriantsoa, Maeva; Hoibian, Solene; Autret, Aurelie; Gilabert, Marine; Sarran, Anthony; Niccoli, Patricia; Raoul, Jean-Luc

    2017-01-01

    In our clinical practice we have observed that despite a high hepatic metastatic tumor burden, serum alkaline phosphatase (AP) levels are frequently normal in cases of metastatic neuroendocrine tumor (NET). We retrospectively reviewed the records of patients with grade 1 and 2 NETs with liver metastases but without bone metastases seen at our institution in 2013. In total, 49 patients were included (22 female), with a median age of 60 years (range: 28 to 84 years). The primary tumors were located in the duodenum/pancreas (n = 29), small bowel (n = 17) or colon/rectum (n = 3); 10 cases were grade 1 and 39 grade 2. Hepatic involvement was bulky, with more than 10 lesions in 23 patients and a tumor burden above 10% of the liver volume in 26 patients. Serum AP levels were elevated (≥ upper limit of normal (ULN)) in 16 patients. In multiparametric analysis, elevated serum AP levels were not associated with the primary site, grade, or number or volume of metastases. In multiparametric analysis, progression-free survival was only correlated with grade (p = 0.010) and AP level (p = 0.017). Serum AP levels are frequently normal in liver metastases from NET, even in the event of a major tumor burden, and the serum AP level can be of prognostic value.

  18. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  19. Electrolyte depletion in white-nose syndrome bats.

    Science.gov (United States)

    Cryan, Paul M; Meteyer, Carol Uphoff; Blehert, David S; Lorch, Jeffrey M; Reeder, DeeAnn M; Turner, Gregory G; Webb, Julie; Behr, Melissa; Verant, Michelle; Russell, Robin E; Castle, Kevin T

    2013-04-01

    The emerging wildlife disease white-nose syndrome is causing widespread mortality in hibernating North American bats. White-nose syndrome occurs when the fungus Geomyces destructans infects the living skin of bats during hibernation, but links between infection and mortality are underexplored. We analyzed blood from hibernating bats and compared blood electrolyte levels to wing damage caused by the fungus. Sodium and chloride tended to decrease as wing damage increased in severity. Depletion of these electrolytes suggests that infected bats may become hypotonically dehydrated during winter. Although bats regularly arouse from hibernation to drink during winter, water available in hibernacula may not contain sufficient electrolytes to offset winter losses caused by disease. Damage to bat wings from G. destructans may cause life-threatening electrolyte imbalances.

  20. Electrolyte depletion in white-nose syndrome bats

    Science.gov (United States)

    Cryan, Paul M.; Meteyer, Carol Uphoff; Blehert, David S.; Lorch, Jeffrey M.; Reeder, DeeAnn M.; Turner, Gregory G.; Webb, Julie; Behr, Melissa; Verant, Michelle L.; Russell, Robin E.; Castle, Kevin T.

    2013-01-01

    The emerging wildlife disease white-nose syndrome is causing widespread mortality in hibernating North American bats. White-nose syndrome occurs when the fungus Geomyces destructans infects the living skin of bats during hibernation, but links between infection and mortality are underexplored. We analyzed blood from hibernating bats and compared blood electrolyte levels to wing damage caused by the fungus. Sodium and chloride tended to decrease as wing damage increased in severity. Depletion of these electrolytes suggests that infected bats may become hypotonically dehydrated during winter. Although bats regularly arouse from hibernation to drink during winter, water available in hibernacula may not contain sufficient electrolytes to offset winter losses caused by disease. Damage to bat wings from G. destructans may cause life-threatening electrolyte imbalances.

  1. Differential diagnostic value of combined detection of serum CA153, CEA and TPA levels in patients with breast tumor

    International Nuclear Information System (INIS)

    Ding Wei

    2007-01-01

    Objective: To assess the differential diagnostic value of combined detection of serum CA153, CEA and TPA levels in patients with breast tumor. Methods: Serum levels of CA153, CEA and TPA were measured with RIA in 269 patients with breast tumor and 150 controls. Results: The serum levels of CA153, CEA and TPA in patients with breast cancer were significantly higher than those in the patients with benign breast tumor and controls. The positive rate of CA153 was 63.8% in the patients with breast cancer and that of CEA and TPA was 22.4% and 62.1% respectively, with combined detection of CA153 and CEA, the positive rate was 69.8%, with CA153 and TPA combined, the positive rate was 87.1%, with the three marker combined, the positive rate was 90.5%. The specificity was 77.9% with CA153, 77.9% with CA153 and CEA, 71.9% with CA153 and TPA, and 73.4% with all the three markers combined. Conclusion: The positive rate was increased remarkably with combined detection of CA153, CEA and TPA, however the specificity was not much changed, so the combined detection was valuable for differential diagnosis. (authors)

  2. Determination of antipsychotic drug in human serum by radioreceptor assay

    International Nuclear Information System (INIS)

    Wu Jinchang; Jiang Yimin

    1989-01-01

    Serum antipsychotic drug in 50 psychosis cases were measured by radioreceptor assay (RRA) and the values were compared in parallel with that by radioimmunoassay (RIA). The results showed that the RRA values were lower than the RIA values, but both assays gave significant correlation between the serum drug level and antipsychotic dose

  3. [A case of IgA2-lambda type M-protein that IgA concentration differs from the values of M-protein by serum protein electrophoresis].

    Science.gov (United States)

    Fukushima, M; Sugano, M; Ichikawa, T; Honda, T; Totsuka, M; Katsuyama, T; Fujita, K

    2001-07-01

    We report an IgA-lambda type M-protein in which the IgA concentration differed from the values of M-protein by serum protein electrophoresis found in a 53-year-old man with multiple myeloma. The M-protein value as determined by serum protein electrophoresis was 6,170 mg/dl. However, the serum IgA concentration was 3,052 mg/dl by turbidimetric immunoassay. Immuno-fixation electrophoresis using IgA subclass antisera revealed that this M-protein was the IgA2-lambda type. Western blotting analysis showed that the IgA2 molecules were composed of two approximately 68 kDa alpha 2 chains and two 28 kDa lambda chains. In addition the free lambda chain band was detected at the position of 28 kDa without 2-mercaptoethanol(2-ME) even though the patient IgA was purified. Since it is known that IgA2m(1) allotype easily release light chains from the IgA molecules in SDS-PAGE without 2-ME, we speculated that in this patient the IgA was the IgA2m(1) allotype. After peripheral blood stem cell transplantation(PBSCT), immunofixation electrophoresis of the patient serum revealed not only the bands of IgA2-lambda type M-protein, but also three bands of IgG1-kappa type M-protein in the gamma region.

  4. Advanced Proton Conducting Polymer Electrolytes for Electrochemical Capacitors

    Science.gov (United States)

    Gao, Han

    Research on solid electrochemical energy storage devices aims to provide high performance, low cost, and safe operation solutions for emerging applications from flexible consumer electronics to microelectronics. Polymer electrolytes, minimizing device sealing and liquid electrolyte leakage, are key enablers for these next-generation technologies. In this thesis, a novel proton-conducing polymer electrolyte system has been developed using heteropolyacids (HPAs) and polyvinyl alcohol for electrochemical capacitors. A thorough understanding of proton conduction mechanisms of HPAs together with the interactions among HPAs, additives, and polymer framework has been developed. Structure and chemical bonding of the electrolytes have been studied extensively to identify and elucidate key attributes affecting the electrolyte properties. Numerical models describing the proton conduction mechanism have been applied to differentiate those attributes. The performance optimization of the polymer electrolytes through additives, polymer structural modifications, and synthesis of alternative HPAs has achieved several important milestones, including: (a) high proton mobility and proton density; (b) good ion accessibility at electrode/electrolyte interface; (c) wide electrochemical stability window; and (d) good environmental stability. Specifically, high proton mobility has been addressed by cross-linking the polymer framework to improve the water storage capability at normal-to-high humidity conditions (e.g. 50-80% RH) as well as by incorporating nano-fillers to enhance the water retention at normal humidity levels (e.g. 30-60% RH). High proton density has been reached by utilizing additional proton donors (i.e. acidic plasticizers) and by developing different HPAs. Good ion accessibility has been achieved through addition of plasticizers. Electrochemical stability window of the electrolyte system has also been investigated and expanded by utilizing HPAs with different heteroatoms

  5. Uranium manufacturing process employing the electrolytic reduction method

    International Nuclear Information System (INIS)

    Oda, Yoshio; Kazuhare, Manabu; Morimoto, Takeshi.

    1986-01-01

    The present invention related to a uranium manufacturing process that employs the electrolytic reduction method, but particularly to a uranium manufacturing process that employs an electrolytic reduction method requiring low voltage. The process, in which uranium is obtained by means of the electrolytic method and with uranyl acid as the raw material, is prior art

  6. Hybrid Metal/Electrolyte Monolithic Low Temperature SOFCs

    National Research Council Canada - National Science Library

    Cochran, Joe

    2004-01-01

    The program objective is to develop SOFCs, operating in the 500-700 degrees C range, based on Metal/Electrolyte square cell honeycomb formed by simultaneous powder extrusion of electrolyte and metal...

  7. Radioimmmunossay of serum 17-alpha-hydroxyprogesterone: methodological considerations

    International Nuclear Information System (INIS)

    Vieira, J.G.H.; Russo, E.M.K.; Maciel, R.M.B.; Verreschi, I.T.N.; Germek, O.A.

    1980-01-01

    A radioimmunological method for the measurement of 17-OH-P in serum is described. An anti-serum with high titer, high coefficient of affinity and good especificity was produced in rabbits using a 17-OH-P derivative coupled to bovine serum albumin through the 3 position. Three preparative methods were studied. Two of them were chromatographic methods (Sephadex LH-20 and Celite) and showed equivalent results; the third method, using simple ether extraction gave higher values. Because of its easy and quick execution, the LH-20 method was chosen for the rest of the study. The method is highly sensitive and accurate enough for clinical use. The values obtained in normal women in the folicular and luteal fases and the values found in patients with 21-hydroxilase defect where comparable to the values found in the literature. (Author) [pt

  8. Electrochemical Study of Hydrocarbon-Derived Electrolytes for Supercapacitors

    Science.gov (United States)

    Noorden, Zulkarnain A.; Matsumoto, Satoshi

    2013-10-01

    In this paper, we evaluate the essential electrochemical properties - capacitive and resistive behaviors - of hydrocarbon-derived electrolytes for supercapacitor application using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The electrolytes were systematically prepared from three hydrocarbon-derived compounds, which have different molecular structures and functional groups, by treatment with high-concentration sulfuric acid (H2SO4) at room temperature. Two-electrode cells were assembled by sandwiching an electrolyte-containing glass wool separator with two active electrodes of activated carbon sheets. The dc electrical properties of the tested cells in terms of their capacitive behavior were investigated by CV, and in order to observe the frequency characteristics of the constructed cells, EIS was carried out. Compared with the tested cell with only high-concentration H2SO4 as the electrolyte, the cell with the derived electrolytes exhibit a capacitance as high as 135 F/g with an improved overall internal resistance of 2.5 Ω. Through the use of a simple preparation method and low-cost precursors, hydrocarbon-derived electrolytes could potentially find large-scale and higher-rating supercapacitor applications.

  9. Impedance and dielectric characterizations of ionic partitioning in interfaces that membranous, biomimetic and gold surfaces form with electrolytes

    International Nuclear Information System (INIS)

    Chilcott, Terry C.; Guo, Chuan

    2013-01-01

    Silicon dioxide, organic monolayers covalently attached to silicon and gold are used as biosensor substrates and anchoring platforms for hybrid, tethered and supported lipid membranes used in membrane-protein studies. Electrical impedance spectroscopy (EIS) studies of gold in contact with potassium chloride electrolytes of concentrations ranging from 1 mM to 300 mM, characterized the gold–electrolyte interface as principally a Stern layer 20–30 Å thick and conductivity many orders of magnitude less than that of the bulk electrolyte. EIS studies of SiO 2 –electrolyte system that were similar to studies of a tetradecane–electrolyte system are presented herein that reveal an interface comprised of at least two interfacial layers and extending some 10 5 Å into the electrolyte. The average conductivity and thickness values for the layer in contact with the SiO 2 surface (∼10 −6 S m −1 and ∼28 Å, respectively) were of the order of magnitude expected for the Gouy–Chapman layer but the dependency of the thickness on concentration did not reflect the expected dependency of the Debye length over the full range of concentrations. The average values for the next layer (∼10 −3 S m −1 and ∼10 5 Å) exhibited a dependency on concentration similar to that expected for the bulk electrolyte. The theoretical derivations of ionic partitioning arising from the Born (dielectric) energy distributions in both the SiO 2 and gold interfaces were generally consistent with the respective EIS studies and revealed that partitioning in the SiO 2 interface mimicked that in bio-membranous interfaces. The dielectric characterizations suggest that; ionic partitioning in biomimetic interfaces play a role in long-ranging sequestration of organic molecules, the extensiveness of these interfaces contributes to differences in the lipid densities of bilayers formed on biomimetic substrates, and chloride ions have a greater affinity than the smaller potassium ions for gold

  10. Vacuum-assisted breast biopsy of suspected mammographic breast diagnoses: predictive value of serum proteomic profile

    International Nuclear Information System (INIS)

    Schittulli, F.; Ventrella, V.

    2009-01-01

    The project planned a series of actions oriented to different scientific questions: to complete the prospective collection of serum samples for serum proteomic analysis according to SOPs needed for the Italy-USA program; the identification of different mammographic signs for prediction of histological diagnosis of breast lesions through mammotone; the analysis of relationship between serum proteomic profile and micro histology characteristics of breast lesions

  11. Facilely solving cathode/electrolyte interfacial issue for high-voltage lithium ion batteries by constructing an effective solid electrolyte interface film

    International Nuclear Information System (INIS)

    Xu, Jingjing; Xia, Qingbo; Chen, Fangyuan; Liu, Tao; Li, Li; Cheng, Xueyuan; Lu, Wei; Wu, Xiaodong

    2016-01-01

    The cathode/electrolyte interface stability is the key factor for the cyclic performance and the safety performance of lithium ion batteries. Suppression of consuming key elements in the electrode materials is essential in this concern. In this purpose, we investigate a facile strategy to solve interfacial issue for high-voltage lithium ion batteries by adding an oxidable fluorinated phosphate, Bis(2,2,2-trifluoroethyl) Phosphite (BTFEP), as a sacrificial additive in electrolyte. We demonstrate that BTFEP additive could be oxidized at slightly above 4.28 V which is a relatively lower voltage than that of solvents, and the oxidative products facilitate in-situ forming a stable solid electrolyte interphase (SEI) film on the cathode surface. The results manifest the SEI film validly restrains the generation of HF and the interfacial side reaction between high-voltage charged LiNi 0.5 Mn 1.5 O 4 (LNMO) and electrolyte, hence, the dissolution of Mn and Ni is effectively suppressed. Finally, the cyclic performance of LNMO after 200 cycles was remarkably improved from 68.4% in blank electrolyte to 95% in 1 wt% BTFEP-adding electrolyte.

  12. Granulosa cell tumors of the ovary : The clinical value of serum inhibin A and B levels in a large single center cohort

    NARCIS (Netherlands)

    Mom, C. H.; Engelen, M. J. A.; Willemse, P. H. B.; Gietema, J. A.; ten Hoor, K. A.; de Vries, E. G. E.; van der Zee, A. G. J.

    Objectives. In patients with a granulosa cell tumor of the ovary, the value of serum inhibin A and B concentrations for the assessment of disease status was investigated. Methods. In 30 consecutive patients with a stage I-III granulosa cell tumor, inhibin A and B concentrations were measured in pre-

  13. Correlation of serum androgens and pituitary hormone levels with serum PSA less than 2.5 ng/ml.

    Science.gov (United States)

    Sofikerim, Mustafa; Oruç, Ozgür; Eskicorapci, Sadettin; Guliyev, Fuat; Ozen, Haluk

    2007-07-27

    The aim of this clinical study was to determine whether there is a relationship between total serum testosterone, free testosterone, FSH (Follicle-Stimulating Hormone), LH (Luteinizing Hormone) and serum prostate specific antigen (PSA) levels. We postulated that such a correlation existed then the use of hormone specific reference ranges might enhance the usefullness of PSA concentrations 40 years of age visiting our urology outpatient clinics. PSA was correlated to age (r = 0.23, p = 0.019), but there none between serum testosterone and age. No significant correlation was noted between testosterone or free testosterone and serum PSA levels, and none between serum FSH or LH and PSA. In age specific reference groups (41-49; 50-59; 60-69 years), we found no significant correlation between PSA and hormone concentrations. In this population of eugonadal men with serum PSA values less than 2.5 ng/ml, serum androgens and pituitary hormones do not appear to correlate with serum PSA.

  14. Prognostic value of serum resistin levels in patients with acute myocardial infarction.

    Science.gov (United States)

    Erer, Hatice Betul; Sayar, Nurten; Guvenc, Tolga Sinan; Aksaray, Sebahat; Yilmaz, Hale; Altay, Servet; Turer, Ayca; Oz, Tugba Kemaloglu; Karadeniz, Fatma Ozpamuk; Oz, Dilaver; Ekmekci, Ahmet; Zencirci, Aycan Esen; Eren, Mehmet

    2014-01-01

    Resistin is a novel adipokine that is suggested to be involved in inflammatory conditions and atherosclerosis. To investigate the prognostic importance of resistin in acute myocardial infarction (AMI) patients. Resistin levels were measured in a population of 132 patients with AMI, of whom 72 (54%) had a diagnosis of ST elevation myocardial infarction (STEMI), and 60 (46%) had non-ST elevation myocardial infarction (NSTEMI). Thirty-three consecutive subjects who were referred to elective coronary angiography due to chest pain evaluation with normal coronary angiograms served as controls. All patients were followed-up for the occurrence of major adverse cardiac events (MACE). There was a significant increase in serum resistin levels in patients with AMI compared to controls (3.71 ± 4.20 vs. 2.00 ± 1.05, p = 0.001, respectively). However, serum resistin levels were similar in patients with STEMI and NSTEMI. (4.26 ± 5.11 vs. 3.06 ± 2.64, p = 0.49, respectively). The patients with MACE had significantly higher levels of serum resistin levels compared to either the AMI or the control group (6.35 ± 5.47, p = 0.005, respectively). Logistic regression analysis revealed that resistin, left ventricular ejection fraction, and coronary artery bypass graft were independent predictors of MACE in AMI patients (OR = 1.11, 95% CI 1.01-1.22, p = 0.03 and OR = 3.84, 95% CI 1.26-11.71, p = 0.018, respectively). Serum resistin level was increased in patients with AMI and constituted a risk factor for MACE in this group.

  15. Electrolytic plasma processing of steel surfaces

    International Nuclear Information System (INIS)

    Bejar, M.A; Araya, R.N; Baeza, B

    2006-01-01

    The thermo-chemical treatments of steels with plasma is normally carried out in low-pressure ionized gaseous atmospheres. Among the treatments used most often are: nitruration, carburization and boronized. A plasma can also generate at atmospheric pressure. One way to produce it is with an electrochemical cell that works at a relatively high inter-electrode voltage and under conditions of heavy gas generation. This type of plasma is known as electrolytic plasma. This work studies the feasibility of using electrolytic plasma for the surface processing of steels. Two processes were selected: boronized and nitruration., for the hardening of two types of steel: one with low carbon (1020) and one with low alloy (4140). In the case of the nitruration, the 1020 steel was first aluminized. The electrolytes were aqueous solutions of borax for the boronizing and urea for the nitruration. The electrolytic plasmas were classified qualitatively, in relation with their luminosity by low, medium and high intensity. The boronizing was carried out with low intensity plasmas for a period of one hour. The nitruration was performed with plasmas of different intensities and for period of a few minutes to half an hour. The test pieces processed by electrolytic plasma were characterized by micro-hardness tests and X-ray diffraction. The maximum surface hardnesses obtained for the 1020 and 4140 steels were the following: 300 and 700 HV for the boronizing, and 1650 and 1200 HV for the nitruration, respectively. The utilization of an electrolytic plasma permits the surface processing of steels, noticeably increasing their hardness. With this type of plasma some thermo-chemical surface treatments can be done very rapidly as well (CW)

  16. Recent results on aqueous electrolyte cells

    KAUST Repository

    Wessells, Colin

    2011-03-01

    The improved safety of aqueous electrolytes makes aqueous lithium-ion batteries an attractive alternative to commercial cells utilizing flammable and expensive organic electrolytes. Two important issues relating to their use have been addressed in this work. One is the extension of the usable voltage range by the incorporation of lithium salts, and the other is the investigation of a useful negative electrode reactant, LiTi 2(PO 4) 3. The electrochemical stability of aqueous lithium salt solutions containing two lithium salts, LiNO 3 and Li 2SO 4, has been characterized using a constant current technique. In both cases, concentrated solutions had effective electrolyte stability windows substantially greater than that of pure water under standard conditions. At an electrolyte leakage current of 10 μA cm -2 between two platinum electrodes in 5 M LiNO 3 the cell voltage can reach 2.0 V, whereas with a leakage current of 50 μA cm -2 it can reach 2.3 V. LiTi 2(PO 4) 3 was synthesized using a Pechini method and cycled in pH-neutral Li 2SO 4. At a reaction potential near the lower limit of electrolyte stability, an initial discharge capacity of 118 mAh g -1 was measured at a C/5 rate, while about 90% of this discharge capacity was retained after 100 cycles. This work demonstrates that it is possible to have useful aqueous electrolyte lithium-ion batteries using the LiTi 2(PO 4) 3 anode with cell voltages of 2 V and above. © 2010 Elsevier B.V. All rights reserved.

  17. Modeling Electrolytically Top-Gated Graphene

    Directory of Open Access Journals (Sweden)

    Mišković ZL

    2010-01-01

    Full Text Available Abstract We investigate doping of a single-layer graphene in the presence of electrolytic top gating. The interfacial phenomenon is modeled using a modified Poisson–Boltzmann equation for an aqueous solution of simple salt. We demonstrate both the sensitivity of graphene’s doping levels to the salt concentration and the importance of quantum capacitance that arises due to the smallness of the Debye screening length in the electrolyte.

  18. Cosolvent electrolytes for electrochemical devices

    Science.gov (United States)

    Wessells, Colin Deane; Firouzi, Ali; Motallebi, Shahrokh; Strohband, Sven

    2018-02-13

    A system and method for stabilizing electrodes against dissolution and/or hydrolysis including use of cosolvents in liquid electrolyte batteries for three purposes: the extension of the calendar and cycle life time of electrodes that are partially soluble in liquid electrolytes, the purpose of limiting the rate of electrolysis of water into hydrogen and oxygen as a side reaction during battery operation, and for the purpose of cost reduction.

  19. High cation transport polymer electrolyte

    Science.gov (United States)

    Gerald, II, Rex E.; Rathke, Jerome W [Homer Glen, IL; Klingler, Robert J [Westmont, IL

    2007-06-05

    A solid state ion conducting electrolyte and a battery incorporating same. The electrolyte includes a polymer matrix with an alkali metal salt dissolved therein, the salt having an anion with a long or branched chain having not less than 5 carbon or silicon atoms therein. The polymer is preferably a polyether and the salt anion is preferably an alkyl or silyl moiety of from 5 to about 150 carbon/silicon atoms.

  20. Determination of serum IgD radioimmunoassay

    International Nuclear Information System (INIS)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l [fr

  1. Electrolytes for Wide Operating Temperature Lithium-Ion Cells

    Science.gov (United States)

    Smart, Marshall C. (Inventor); Bugga, Ratnakumar V. (Inventor)

    2016-01-01

    Provided herein are electrolytes for lithium-ion electrochemical cells, electrochemical cells employing the electrolytes, methods of making the electrochemical cells and methods of using the electrochemical cells over a wide temperature range. Included are electrolyte compositions comprising a lithium salt, a cyclic carbonate, a non-cyclic carbonate, and a linear ester and optionally comprising one or more additives.

  2. Changes of hormones regulating electrolyte metabolism after space flight and hypokinesia

    Science.gov (United States)

    Macho, L.; Fickova, M.; Lichardus, B.; Kvetnansky, R.; Carrey, R. M.; Grigoriev, A.; Popova, I. A.; Tigranian, R. A.; Noskov, V. B.

    The changes of hormones in plasma involved in the body fluid regulation were studied in human subjects during and after space flights in relation to redistribution of body fluids in the state of weightlessness. Since hypokinesia was used as a model for simulation of some effects of the stay in microgravity the plasma hormone levels in rats exposed to hypokinesia were also investigated. Plasma aldosterone values showed great individual variations during the first inflight days, the increased levels were observed with prolongation of space flights. The important elevation was found in the recovery period, however it was interesting to note, that in some cosmonauts with repeated exposure to space flight, the postflight plasma aldosterone levels were not elevated. The urine excretion of aldosterone was increased inflight, however in postflight period the decrease or increase were found in the first 1-5 days. The increase of plasma renin activity was observed in flight and postflight period. The rats were exposed to hypokinesia (forced restriction of motor activity) for 1, 7 and 60 days and urine was collected during last 24 hours. The animals were sacrificed and the concentration of electrolytes and of levels of corticosterone aldosteron (A), ANF and plasma-renin activity (PRA) were determined in plasma. In urine excretion of sodium and potassium were estimated. An important increase of plasma renin activity and aldosterone concentration was found after short-term hypokinesia (1 day). These hormonal values appear to decrease with time (7 days) and are not significantly different from controls after long-term hypokinesia (60 days). A decrease of values ANF in plasma was observed after 1 and 7 days hypokinesia. After prolonged hypokinesia a decrease of sodium plasma concentration was observed. The excretion of sodium in urine was higher in long-term hypokinetic animals. There were no significant changes of plasma potassium levels in rats exposed to hypokinesia, however

  3. A review of electrolyte materials and compositions for electrochemical supercapacitors.

    Science.gov (United States)

    Zhong, Cheng; Deng, Yida; Hu, Wenbin; Qiao, Jinli; Zhang, Lei; Zhang, Jiujun

    2015-11-07

    Electrolytes have been identified as some of the most influential components in the performance of electrochemical supercapacitors (ESs), which include: electrical double-layer capacitors, pseudocapacitors and hybrid supercapacitors. This paper reviews recent progress in the research and development of ES electrolytes. The electrolytes are classified into several categories, including: aqueous, organic, ionic liquids, solid-state or quasi-solid-state, as well as redox-active electrolytes. Effects of electrolyte properties on ES performance are discussed in detail. The principles and methods of designing and optimizing electrolytes for ES performance and application are highlighted through a comprehensive analysis of the literature. Interaction among the electrolytes, electro-active materials and inactive components (current collectors, binders, and separators) is discussed. The challenges in producing high-performing electrolytes are analyzed. Several possible research directions to overcome these challenges are proposed for future efforts, with the main aim of improving ESs' energy density without sacrificing existing advantages (e.g., a high power density and a long cycle-life) (507 references).

  4. Theory of electroreduction of solid oxide electrolytes. Kinetics and mechanism of the galvanostatic process with blocking cathodes

    International Nuclear Information System (INIS)

    Chebotin, V.N.; Brainin, M.I.; Lukach, Yu. S.; Pakhnutov, I.A.; Solov'eva, L.M.

    1986-01-01

    This paper discusses dc flow through cells with MO 2 + MeOΓ solid electrolyte (M = Zr, Hf, Ce, or Th; Me = Ca, Sr, Sc, Y, or lanthanides), a blocking cathode, and a reversible anode which leads to departures of the electrolytes from stoichiometry in the direction of oxygen deficiency. A nonlinear differential equation of the diffusion type describes the degree of this departure and the n-type electronic conductivity which is proportional to it, as functions of the coordinate and time. The electrolyte's electronic conductivity increases with time near the cathode, and approaches a limiting value that is proportional to the current being passed. The electronic conductivity falls off exponentially with increasing distance from the cathode; this changes to a linear fall as a function of time

  5. Prevalence of Electrolyte Disorders Among Cases of Diarrhea with Severe Dehydration and Correlation of Electrolyte Levels with Age of the Patients.

    Science.gov (United States)

    Ahmad, Mirza Sultan; Wahid, Abdul; Ahmad, Mubashra; Mahboob, Nazia; Mehmood, Ramlah

    2016-05-01

    To find out the prevalence of electrolyte disorders among children with severe dehydration, and to study correlation between age and electrolyte, urea and creatinine levels. Prospective, analytical study. Outdoor and indoor of Fazle-Omar Hospital, Rabwah, Pakistan, from January to December 2012. All patients from birth to 18 years age, presenting with diarrhea and severe dehydration were included in the study. Urea, creatinine and electrolyte levels of all patients included in the study were checked and recorded in the data form with name, age and outcome. The prevalence of electrolyte disorders were ascertained and correlation with age was determined by Pearson's coefficient. At total of 104 patients were included in the study. None of the patients died. Hyperchloremia was the commonest electrolyte disorder (53.8%), followed by hyperkalemia (26.9%) and hypernatremia (17.3%). Hyponatremia, hypokalemia and hypochloremia were present in 10.6%, 7.7%, and 10.6% cases, respectively. Weak negative correlation was found between age and chloride and potassium levels. Different electrolyte disorders are common in children with diarrhea-related severe dehydration.

  6. Monitoring electrolyte concentrations in redox flow battery systems

    Science.gov (United States)

    Chang, On Kok; Sopchak, David Andrew; Pham, Ai Quoc; Kinoshita, Kimio

    2015-03-17

    Methods, systems and structures for monitoring, managing electrolyte concentrations in redox flow batteries are provided by introducing a first quantity of a liquid electrolyte into a first chamber of a test cell and introducing a second quantity of the liquid electrolyte into a second chamber of the test cell. The method further provides for measuring a voltage of the test cell, measuring an elapsed time from the test cell reaching a first voltage until the test cell reaches a second voltage; and determining a degree of imbalance of the liquid electrolyte based on the elapsed time.

  7. Theoretical and experimental study of mixed solvent electrolytes

    International Nuclear Information System (INIS)

    Cummings, P.T.; O'Connell, J.P.

    1990-01-01

    In the original proposal to study mixed solvent electrolyte solutions, four major goals were formulated: fundamental modeling of mixed solvent electrolytes using numerically solved integral equation approximation theories; evaluation of intermolecular pair potential models by computer simulation of selected systems for comparison with experiment and the numerical integral equation studies; development of fundamentally based correlations for the thermodynamic properties of mixed solvent electrolyte solutions using analytically solvable statistical mechanical models; and extension of experimental database on mixed solvent electrolytes by performing vapor-liquid equilibrium measurements on selected systems. This paper discusses the progress on these goals

  8. Introduction. Aluminium production on electrolytic cells with calcined anodes

    International Nuclear Information System (INIS)

    Galushkin, N.V.

    1995-01-01

    This chapter presents the monograph content, which includes the description of physicochemical processes in aluminium electrolytic cells, and mechanism of electrolytic aluminium obtaining. The short description of aluminium electrolytic cells construction is presented in this book as well.

  9. Low temperature solid oxide electrolytes (LT-SOE): A review

    Science.gov (United States)

    Singh, B.; Ghosh, S.; Aich, S.; Roy, B.

    2017-01-01

    Low temperature solid oxide fuel cell (LT-SOFC) can be a source of power for vehicles, online grid, and at the same time reduce system cost, offer high reliability, and fast start-up. A huge amount of research work, as evident from the literature has been conducted for the enhancement of the ionic conductivity of LT electrolytes in the last few years. The basic conduction mechanisms, advantages and disadvantages of different LT oxide ion conducting electrolytes {BIMEVOX systems, bilayer systems including doped cerium oxide/stabilised bismuth oxide and YSZ/DCO}, mixed ion conducting electrolytes {doped cerium oxides/alkali metal carbonate composites}, and proton conducting electrolytes {doped and undoped BaCeO3, BaZrO3, etc.} are discussed here based on the recent research articles. Effect of various material aspects (composition, doping, layer thickness, etc.), fabrication methods (to achieve different microstructures and particle size), design related strategies (interlayer, sintering aid etc.), characterization temperature & environment on the conductivity of the electrolytes and performance of the fuel cells made from these electrolytes are shown in tabular form and discussed. The conductivity of the electrolytes and performance of the corresponding fuel cells are compared. Other applications of the electrolytes are mentioned. A few considerations regarding the future prospects are pointed.

  10. Age-Dependent Decrease in Serum Transforming Growth Factor (TGF-Beta 1 in Healthy Japanese Individuals; Population Study of Serum TGF-Beta 1 Level in Japanese

    Directory of Open Access Journals (Sweden)

    Yoshihiro Okamoto

    2005-01-01

    Full Text Available Transforming growth factor-beta1 (TGF-β1, a multi-functional cytokine, is involved in regulating a variety of cellular activities and the serum/plasma TGF-β1 level is altered with various diseases. However, most published reports have described adult patients, and so we investigated the clinical significance of serum TGF-β1 level in pediatric patients. The diagnostic application of the measurement of serum TGF-β1 level depends critically on the control value, however, there is no information on the control value of serum TGF-β1 for children.

  11. Solid electrolytes general principles, characterization, materials, applications

    CERN Document Server

    Hagenmuller, Paul

    1978-01-01

    Solid Electrolytes: General Principles, Characterization, Materials, Applications presents specific theories and experimental methods in the field of superionic conductors. It discusses that high ionic conductivity in solids requires specific structural and energetic conditions. It addresses the problems involved in the study and use of solid electrolytes. Some of the topics covered in the book are the introduction to the theory of solid electrolytes; macroscopic evidence for liquid nature; structural models; kinetic models; crystal structures and fast ionic conduction; interstitial motion in

  12. Electrochemical behavior of ionically crosslinked polyampholytic gel electrolytes

    International Nuclear Information System (INIS)

    Chen Wanyu; Tang Haitao; Ou Ziwei; Wang Hong; Yang Yajiang

    2007-01-01

    An ionic complex of anionic and cationic monomers was obtained by protonation of (N,N-diethylamino)ethylmethacrylate (DEA) with acrylic acid (AAc). Free radical copolymerization of the ionic complex and acrylamide (AAm), yielded the ionically crosslinked polyampholytic gel electrolytes [poly(AAc-DEA-AAm), designated as PADA] using two types of organic solvents containing a lithium salt. The PADA gel electrolyte exhibited good thermal stability shown by the DSC thermogram. The impedance analysis at temperatures ranging from -30 to 75 deg. C indicated that the ionic conductivities of the PADA gel electrolytes were rather close to those of liquid electrolytes. The temperature dependence of the ionic conductivities was found to be in accord with the Arrhenius equation. Moreover, the ionic conductivities of PADA gel electrolytes increased with an increase of the molar ratios of cationic/anionic monomers. The ionic conductivities of PADA gels prepared in solvent mixtures of propylene carbonate, ethyl methyl ether and dioxolane (3:1:1, v/v) were higher than those of PADA gels prepared in propylene carbonate only. Significantly, the ionic conductivities of two kinds of PADA gel electrolytes were in the range of 10 -3 and 10 -4 S cm -1 even at -30 deg. C. The electrochemical windows of PADA gel electrolytes measured by cyclic voltammetry were in the range from -1 V to 4.5 V

  13. Hematocrit and Serum Hemoglobin Do Not Influence Values in Computed Tomography Perfusion of Patients With Acute Ischemic Stroke.

    Science.gov (United States)

    Karwacki, Grzegorz Marek; Benz, Matthias Richard; Tyndall, Anthony Joseph; Ulmer, Stephan

    There is a correlation between both serum hemoglobin (HGB) and hematocrit (HCT) and attenuation values of vessels in noncontrast-enhanced computed tomography (NECT), which could influence calculated perfusion maps in CT perfusion. We retrospectively included 45 patients, who presented with acute new neurological symptoms and underwent NECT and CT perfusion (128-row multi detector scanner, coverage: 6.9 cm craniocaudally; 80 kV; 200 mAs; temporal resolution: 2 seconds using 40 mL Ultravist 370 at a flow rate of 5 mL/s) on admission and a follow-up MRI within 1 week of admission. Hematocrit, HGB, and attenuation values did not differ between patients with stroke and controls. A statistically significant correlation was found between HCT and HGB and attenuation values in the internal carotid artery or middle cerebral artery on NECT (P Hematocrit and HGB do not influence calculated perfusion maps. There is no need for HCT/HGB-adjusted cerebral blood volume thresholds in stroke patients.

  14. Unraveling the electrolyte properties of Na3SbS4 through computation and experiment

    Science.gov (United States)

    Rush, Larry E.; Hood, Zachary D.; Holzwarth, N. A. W.

    2017-12-01

    Solid-state sodium electrolytes are expected to improve next-generation batteries on the basis of favorable energy density and reduced cost. Na3SbS4 represents a new solid-state ion conductor with high ionic conductivities in the mS/cm range. Here, we explore the tetragonal phase of Na3SbS4 and its interface with metallic sodium anode using a combination of experiments and first-principles calculations. The computed Na-ion vacancy migration energies of 0.1 eV are smaller than the value inferred from experiment, suggesting that grain boundaries or other factors dominate the experimental systems. Analysis of symmetric cells of the electrolyte—Na/Na 3SbS4/Na —show that a conductive solid electrolyte interphase forms. Computer simulations infer that the interface is likely to be related to Na3SbS3 , involving the conversion of the tetrahedral SbS43 - ions of the bulk electrolyte into trigonal pyramidal SbS33 - ions at the interface.

  15. Preparation and Characterization of PVA Alkaline Solid Polymer Electrolyte with Addition of Bamboo Charcoal

    Directory of Open Access Journals (Sweden)

    Lidan Fan

    2018-04-01

    Full Text Available Natural bamboo charcoal (BC powder has been developed as a novel filler in order to further improve performances of the polyvinyl alcohol (PVA-based alkaline solid polymer electrolyte (ASPE by solution casting method. X-ray diffraction patterns of composite polymer electrolyte with BC revealed the decrease in the degree of crystallinity with increasing content of BC. Scanning electron microscopy images showed pores on a micrometer scale (average diameter about 2 μm distributed inside and on the surface of the membranes, indicating a three-dimension network formed in the polymer framework. The ionic conductivity was measured by the alternating-current (AC impedance method, and the highest conductivity value of 6.63 × 10−2 S·cm−1 was obtained with 16 wt % of BC content and mKOH:mPVA = 2:1.5 at 30 °C. The contents of BC and KOH could significantly influence the conductivity. The temperature dependence of the bulk electrical conductivity displayed a combination of Arrhenius nature, and the activation energy for the ion in polymer electrolyte has been calculated. The electrochemical stability window of the electrolyte membrane was over 1.6 V. The thermogravimetric analysis curves showed that the degradation temperatures of PVA-BC-KOH ASPE membranes shifted toward higher with adding BC. A simple nickel-hydrogen battery containing PVA-BC-KOH electrolyte membrane was assembled with a maximum discharge capacity of 193 mAh·g−1.

  16. Preparation and Characterization of PVA Alkaline Solid Polymer Electrolyte with Addition of Bamboo Charcoal.

    Science.gov (United States)

    Fan, Lidan; Wang, Mengyue; Zhang, Zhen; Qin, Gang; Hu, Xiaoyi; Chen, Qiang

    2018-04-26

    Natural bamboo charcoal (BC) powder has been developed as a novel filler in order to further improve performances of the polyvinyl alcohol (PVA)-based alkaline solid polymer electrolyte (ASPE) by solution casting method. X-ray diffraction patterns of composite polymer electrolyte with BC revealed the decrease in the degree of crystallinity with increasing content of BC. Scanning electron microscopy images showed pores on a micrometer scale (average diameter about 2 μm) distributed inside and on the surface of the membranes, indicating a three-dimension network formed in the polymer framework. The ionic conductivity was measured by the alternating-current (AC) impedance method, and the highest conductivity value of 6.63 × 10 −2 S·cm −1 was obtained with 16 wt % of BC content and m KOH : m PVA = 2:1.5 at 30 °C. The contents of BC and KOH could significantly influence the conductivity. The temperature dependence of the bulk electrical conductivity displayed a combination of Arrhenius nature, and the activation energy for the ion in polymer electrolyte has been calculated. The electrochemical stability window of the electrolyte membrane was over 1.6 V. The thermogravimetric analysis curves showed that the degradation temperatures of PVA-BC-KOH ASPE membranes shifted toward higher with adding BC. A simple nickel-hydrogen battery containing PVA-BC-KOH electrolyte membrane was assembled with a maximum discharge capacity of 193 mAh·g −1 .

  17. Serum magnesium and calcium in preeclampsia: a comparative study at the Korle-Bu Teaching Hospital, Ghana

    Directory of Open Access Journals (Sweden)

    Owusu Darkwa E

    2017-08-01

    Full Text Available Ebenezer Owusu Darkwa,1 Charles Antwi-Boasiako,2 Robert Djagbletey,1 Christian Owoo,1 Samuel Obed,3,† Daniel Sottie4 1Department of Anaesthesia, University of Ghana School of Medicine and Dentistry, 2Department of Physiology, University of Ghana School of Biomedical and Allied Health Sciences, 3Department of Obstetrics and Gynaecology, University of Ghana School of Medicine and Dentistry, College of Health Sciences, 4Department of Anaesthesia, Korle-Bu Teaching Hospital, Accra, Ghana †Samuel Obed passed away on May 12, 2017 Background: A large percentage (16% of maternal mortality in developed countries, compared to 9% in developing countries, is due to hypertensive disorders in pregnancy. The etiology of preeclampsia remains unknown, with poorly understood pathophysiology. Magnesium and calcium play an important role in vascular smooth muscle function and therefore a possible role in the development of preeclampsia.Aim: We aimed to compare serum magnesium and total calcium levels of preeclamptic and normal pregnant women at the Korle-Bu Teaching Hospital in Ghana.Patients and methods: A comparative cross-sectional study involving 30 normal pregnant and 30 preeclamptic women with >30 weeks gestation and aged 18–35 years, was conducted at the Korle-Bu Teaching Hospital. Magnesium and calcium were determined using a flame atomic absorption spectrometer.Results: Mean serum magnesium and total calcium levels in preeclamptic women were 0.70±0.15 and 2.13±0.30 mmol/L, respectively. Mean serum magnesium and total calcium levels in normal pregnant women were 0.76±0.14 and 2.13±0.35 mmol/L, respectively. There was a statistically nonsignificant difference in serum magnesium and total calcium in preeclamptic women compared to normal pregnant women, with p-values of 0.092 and 0.972, respectively.Conclusion: Serum magnesium and total calcium, therefore, seem not to differ in preeclamptic women compared to normal pregnant women in Ghana

  18. Developing New Electrolytes for Advanced Li-ion Batteries

    Science.gov (United States)

    McOwen, Dennis Wayne

    The use of renewable energy sources is on the rise, as new energy generating technologies continue to become more efficient and economical. Furthermore, the advantages of an energy infrastructure which relies more on sustainable and renewable energy sources are becoming increasingly apparent. The most readily available of these renewable energy sources, wind and solar energy in particular, are naturally intermittent. Thus, to enable the continued expansion and widespread adoption of renewable energy generating technology, a cost-effective energy storage system is essential. Additionally, the market for electric/hybrid electric vehicles, which both require efficient energy storage, continues to grow as more consumers seek to reduce their consumption of gasoline. These vehicles, however, remain quite expensive, due primarily to costs associated with storing the electrical energy. High-voltage and thermally stable Li-ion battery technology is a promising solution for both grid-level and electric vehicle energy storage. Current limitations in materials, however, limit the energy density and safe operating temperature window of the battery. Specifically, the state-of-the-art electrolyte used in Li-ion batteries is not compatible with recently developed high-voltage positive electrodes, which are one of the most effectual ways of increasing the energy density. The electrolyte is also thermally unstable above 50 °C, and prone to thermal runaway reaction if exposed to prolonged heating. The lithium salt used in such electrolytes, LiPF6, is a primary contributor to both of these issues. Unfortunately, an improved lithium salt which meets the myriad property requirements for Li-ion battery electrolytes has eluded researchers for decades. In this study, a renewed effort to find such a lithium salt was begun, using a recently developed methodology to rapidly screen for desirable properties. Four new lithium salts and one relatively new but uncharacterized lithium salt were

  19. Diagnostic value of serum creatine kinase-BB for acute meningitis in adults

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Alavi

    2017-01-01

    Full Text Available Objective: To find out an easy and feasible test instead of cerebrospinal fluid analysis for the diagnosis of acute meningitis. Methods: This cross-sectional study was conducted in 2013 in Ahvaz, a city located in the Southwest Iran including 75 patients with clinical diagnosis of fever, headache, vomiting and neck stiffness suspected to have acute meningitis based on cerebrospinal fluid analysis. In the beginning, the patients were divided into two categories as acute meningitis, and non-acute meningitis. Then, 5 L of blood was taken from each patient to determine serum creatine kinase isoenzyme-BB by using ELISA method. After that, the related data including demographics, clinical and laboratory results were analyzed by SPSS software version 16 using Chi-square test for qualitative variables and student’s t-test for quantitative variables. Results: Among the total 75 patients, 37 (49.3% were males and 38 (50.7% were females including 45 patients (60% with acute meningitis and 30 patients (40% without acute meningitis. On the other hand, CK-BB serum levels in acute meningitis and non-acute meningitis patients were 18.23 ± 7.56 and 2.67 ± 1.62, respectively, so significant difference was found between acute meningitis group and non-acute meningitis group (P < 0.000 1. Conclusions: Serum creatine kinase isoenzyme-BB test is a useful test to differentiate acute meningitis from non-acute meningitis among suspected cases of meningitis disease, so measuring the CK-BB serum level in Iran's health system with an expanded health setting especially in remote areas will be useful and helpful in prompt diagnosis and treatment of the acute meningitis.

  20. Evaluation of serum and milk ELISAs for paratuberculosis in Danish dairy cattle

    DEFF Research Database (Denmark)

    Klausen, Joan; Huda, A.; Ekeroth, Lars

    2003-01-01

    concurrently from six dairy herds infected with MAP and from two dairy herds without history of infection with MAP. A cut-off value of 7 OD% was used in the ELISAs. At this cut-off value, all six culture-positive herds were positive in the serum ELISA but one was negative in the milk ELISA. All six culture......-positive herds were positive in the CFT. In the two culture-negative herds, the serum and the milk ELISA deemed all serum samples negative at this cut-off value, whereas four serum samples from one of these herds were positive in the CFT. The highest cut-off value enabling the milk ELISA to record all six...... culture-positive herds as positive was 4 OD%. The highest cut-off value enabling the serum ELISA to record all six culture-positive herds as positive was 17 OD%. Individual-sample relative sensitivities of the ELISAs ranged from 49 to 64% and relative specificities were 80-96% at the cut-off values of 4...

  1. Serum Thyroxine to Thyroxine-Binding Globulin Ratio in Pregnancy and Newborn

    International Nuclear Information System (INIS)

    Kim, Ji Yeul

    1982-01-01

    To evaluate the diagnostic value of the ratio of serum thyroxine(T 4 ) /thyroxine-binding globulin (TBG) for the thyroid status in pregnancy and newborn serum thyroxine, TBG, triiodothyronine, and free thyroxine levels were radioimmunoassayed in normal pregnant women at each of the trimesters, and the calculated serum T 4 /TBG ratios were compared with other parameters such as T 3 /TBG ratio and free T 4 /TBG ratio and free T 4 /TBG ratio. Serum T 4 levels were elevated with the proportionate increase in TBG levels during pregnancy, leading to the nearly constant value of serum T 4 /TBG ratios as in normal non-pregnant controls. In contrast, serum T 3 /TBG and free T 4 /TBG ratios varied considerably during pregnancy. In newborn, T 4 levels were nearly not changed with compared non-pregnant control value and TBG levels were elevated. The results indicate that serum T 4 /TBG ratio is a better parameter than others in evaluating the thyroid status during pregnancy and but newborn is a no better.

  2. Ionic-Liquid-Based Polymer Electrolytes for Battery Applications.

    Science.gov (United States)

    Osada, Irene; de Vries, Henrik; Scrosati, Bruno; Passerini, Stefano

    2016-01-11

    The advent of solid-state polymer electrolytes for application in lithium batteries took place more than four decades ago when the ability of polyethylene oxide (PEO) to dissolve suitable lithium salts was demonstrated. Since then, many modifications of this basic system have been proposed and tested, involving the addition of conventional, carbonate-based electrolytes, low molecular weight polymers, ceramic fillers, and others. This Review focuses on ternary polymer electrolytes, that is, ion-conducting systems consisting of a polymer incorporating two salts, one bearing the lithium cation and the other introducing additional anions capable of plasticizing the polymer chains. Assessing the state of the research field of solid-state, ternary polymer electrolytes, while giving background on the whole field of polymer electrolytes, this Review is expected to stimulate new thoughts and ideas on the challenges and opportunities of lithium-metal batteries. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Effect of an electrolyte salt dissolving in polysiloxane-based electrolyte on passive film formation on a graphite electrode

    Science.gov (United States)

    Nakahara, Hiroshi; Nutt, Steven

    Electrochemical impedance spectroscopy (EIS) was performed during the first charge of a graphite/lithium metal test cell to determine the effect of an electrolyte salt on passive film formation in a polysiloxane-based electrolyte. The graphite electrode was separated from the lithium metal electrode by a porous polyethylene membrane immersed in a polysiloxane-based electrolyte with the dissolved lithium bis(oxalato) borate (LiBOB) or lithium bis(trifluoromethanesulfonyl) imide (LiTFSI). In case of LiTFSI, the conductivity of system decreased at 1.2 V. In contrast, for the case of LiBOB, the conductivity decreased at 1.7 V. The magnitudes of charge transfer resistance and film resistance for LiTFSI were smaller than that for LiBOB. Passive films on highly oriented pyrolytic graphite (HOPG) after charging (lithiating) in polysiloxane-based electrolyte were inspected microscopically. Gel-like film and island-like films were observed for LiBOB [H. Nakahara, A. Masias, S.Y. Yoon, T. Koike, K. Takeya, Proceedings of the 41st Power Sources Conference, vol. 165, Philadelphia, June 14-17, 2004; H. Nakahara, S.Y. Yoon, T. Piao, S. Nutt, F. Mansfeld, J. Power Sources, in press; H. Nakahara, S.Y. Yoon, S. Nutt, J. Power Sources, in press]. However, for LiTFSI, there was sludge accumulation on the HOPG surface. Compositional analysis revealed the presence of silicon on both HOPG specimens with LiBOB and with LiTFSI. The electrolyte salt dissolved in the polysiloxane-based electrolyte changed the electrochemical and morphological nature of passive films on graphite electrode.

  4. Electrolytic pickling of duplex stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Ipek, N.; Holm, B.; Pettersson, R. [Swedish Institute for Metals Research, Drottning Kristinas vaeg 48, 11428 Stockholm (Sweden); Runnsjoe, G.; Karlsson, M. [Outokumpu Stainless AB, 77422 Avesta (Sweden)

    2005-08-01

    Pickling of duplex stainless steels has proved to be much more difficult than that of standard austenitic grades. Electrolytic pre-pickling is shown to be a key process towards facilitating the pickling process for material annealed both in the production-line and in laboratory experiments. The mechanism for the neutral electrolytic process on duplex 2205 and austenitic 316 steels has been examined and the oxide scale found to become thinner as a function of electrolytic pickling time. Spallation or peeling of the oxide induced by gas evolution did not play a decisive role. A maximum of about 20% of the current supplied to the oxidised steel surface goes to dissolution reactions whereas about 80% of the current was consumed in oxygen gas production. This makes the current utilisation very poor, particularly against the background of reports that in indirect electrolytic pickling only about 30% of the total current, supplied to the process, actually goes into the strip. A parametric study was therefore carried out to determine whether adjustment of process variables could improve the current utilisation. (Abstract Copyright [2005], Wiley Periodicals, Inc.)

  5. Physical properties of molten carbonate electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, T.; Yanagida, M.; Tanimoto, K. [Osaka National Research Institute (Japan)] [and others

    1996-12-31

    Recently many kinds of compositions of molten carbonate electrolyte have been applied to molten carbonate fuel cell in order to avoid the several problems such as corrosion of separator plate and NiO cathode dissolution. Many researchers recognize that the addition of alkaline earth (Ca, Sr, and Ba) carbonate to Li{sub 2}CO{sub 3}-Na{sub 2}CO{sub 3} and Li{sub 2}CO{sub 3}-K{sub 2}CO{sub 3} eutectic electrolytes is effective to avoid these problems. On the other hand, one of the corrosion products, CrO{sub 4}{sup 2-} ion is found to dissolve into electrolyte and accumulated during the long-term MCFC operations. This would affect the performance of MCFC. There, however, are little known data of physical properties of molten carbonate containing alkaline earth carbonates and CrO{sub 4}{sup 2-}. We report the measured and accumulated data for these molten carbonate of electrical conductivity and surface tension to select favorable composition of molten carbonate electrolytes.

  6. The Comparison Of TSH IRMA Serum Level With TRH Test Value In Healthy People Who Are Suspected To Have Hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Keshavarz zirak A

    2005-06-01

    Full Text Available Background: Sub clinical hyperthyroidism is a state of subnormal serum TSH and T3,T4 within normal range, although usually without overt clinical manifestation but many disastrous complications especially in senile patient. In Iranian people, serum TSH is generally assayed by IRMA method. This study is aimed to determine the value of low serum TSH in these patients, better management and decision when encountered. Materials and Methods: The populations under study are guys with serum TSH lower than 0.5mu/l and normal thyroid hormones without known thyroidal and non-thyroidal illness. A basal serum TSH and TSH 30 minutes after TRH injection intra venous were sampled and correlation of clinical signs and symptoms and basal TSH with sub clinical hyperthyroidism was considered. Results: The population under study was categorized into five groups and prevalence of sub clinical hyperthyroidism was noted. In patients with b.TSH equal or lower than 0.1mu/l, 100%, 0.1-0.2mu/l, 75%, 0.2-0.3mu/l, 38.5%, 0.3-0.4mu/l, 14.3% and TSH levels greater than 0.4mu/l, were all normal. After analyzing of these data and determination of sensitivity and specificity of IRMA, it was concluded that IRMA is not sufficient to distinguish sub clinical hyperthyroidism, although there is a good linear (r=0.68; P<0.001 and cubic (r=0.79; P<0.001 relationship between b.TSH and d.TSH. Conclusion: Since TRH test is not cost effective for all cases, TSH levels lower than 0.25mu/l, can be considered as sub clinical hyperthyroidism and levels more than 0.4mu/l, as normal. In cases with TSH level between 0.25 and 0.4mu/l, TRH test is needed in high-risk patients.

  7. Progress in electrolytes for rechargeable Li-based batteries and beyond

    Directory of Open Access Journals (Sweden)

    Qi Li

    2016-04-01

    Full Text Available Owing to almost unmatched volumetric energy density, Li-based batteries have dominated the portable electronic industry for the past 20 years. Not only will that continue, but they are also now powering plug-in hybrid electric vehicles and zero-emission vehicles. There is impressive progress in the exploration of electrode materials for lithium-based batteries because the electrodes (mainly the cathode are the limiting factors in terms of overall capacity inside a battery. However, more and more interests have been focused on the electrolytes, which determines the current (power density, the time stability, the reliability of a battery and the formation of solid electrolyte interface. This review will introduce five types of electrolytes for room temperature Li-based batteries including 1 non-aqueous electrolytes, 2 aqueous solutions, 3 ionic liquids, 4 polymer electrolytes, and 5 hybrid electrolytes. Besides, electrolytes beyond lithium-based systems such as sodium-, magnesium-, calcium-, zinc- and aluminum-based batteries will also be briefly discussed. Keywords: Electrolyte, Ionic liquid, Polymer, Hybrid, Battery

  8. Large-current-controllable carbon nanotube field-effect transistor in electrolyte solution

    Science.gov (United States)

    Myodo, Miho; Inaba, Masafumi; Ohara, Kazuyoshi; Kato, Ryogo; Kobayashi, Mikinori; Hirano, Yu; Suzuki, Kazuma; Kawarada, Hiroshi

    2015-05-01

    Large-current-controllable carbon nanotube field-effect transistors (CNT-FETs) were fabricated with mm-long CNT sheets. The sheets, synthesized by remote-plasma-enhanced CVD, contained both single- and double-walled CNTs. Titanium was deposited on the sheet as source and drain electrodes, and an electrolyte solution was used as a gate electrode (solution gate) to apply a gate voltage to the CNTs through electric double layers formed around the CNTs. The drain current came to be well modulated as electrolyte solution penetrated into the sheets, and one of the solution gate CNT-FETs was able to control a large current of over 2.5 A. In addition, we determined the transconductance parameter per tube and compared it with values for other CNT-FETs. The potential of CNT sheets for applications requiring the control of large current is exhibited in this study.

  9. Determination of hydration numbers of electrolytes from temperature dependence of PMR chemical shifts

    International Nuclear Information System (INIS)

    Subramanian, N.

    1979-01-01

    The method proposed by Malinowski et al. for the determination of effective hydration numbers (h) of electrolytes leads to a consistent incrrease in the observed values of 'h' with increase in solution concentration. An attempt is made to rationalize the experimental results by cosidering the simultaneous effects of temperature and concentration on the proton chemical shift. It is suggested that Malinowski's technique might yeld 'h' values very close to the true value for those ions for which there is a fortuitous cancellation of structure-making and structure-breaking properties. (Author) [pt

  10. Composition and particle size of electrolytic copper powders prepared in water-containing dimethyl sulfoxide electrolytes

    Science.gov (United States)

    Mamyrbekova, Aigul'; Abzhalov, B. S.; Mamyrbekova, Aizhan

    2017-07-01

    The possibility of the electroprecipitation of copper powder via the cathodic reduction of an electrolyte solution containing copper(II) nitrate trihydrate and dimethyl sulfoxide (DMSO) is shown. The effect electrolysis conditions (current density, concentration and temperature of electrolyte) have on the dimensional characteristics of copper powder is studied. The size and shape of the particles of the powders were determined by means of electron microscopy; the qualitative composition of the powders, with X-ray diffraction.

  11. Serum Metabonomics of Mild Acute Pancreatitis.

    Science.gov (United States)

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  12. Non-aqueous electrolyte for high voltage rechargeable magnesium batteries

    Science.gov (United States)

    Doe, Robert Ellis; Lane, George Hamilton; Jilek, Robert E; Hwang, Jaehee

    2015-02-10

    An electrolyte for use in electrochemical cells is provided. The properties of the electrolyte include high conductivity, high Coulombic efficiency, and an electrochemical window that can exceed 3.5 V vs. Mg/Mg.sup.+2. The use of the electrolyte promotes the electrochemical deposition and dissolution of Mg without the use of any Grignard reagents, other organometallic materials, tetraphenyl borate, or tetrachloroaluminate derived anions. Other Mg-containing electrolyte systems that are expected to be suitable for use in secondary batteries are also described.

  13. Solid composite electrolytes for lithium batteries

    Science.gov (United States)

    Kumar, Binod; Scanlon, Jr., Lawrence G.

    2000-01-01

    Solid composite electrolytes are provided for use in lithium batteries which exhibit moderate to high ionic conductivity at ambient temperatures and low activation energies. In one embodiment, a ceramic-ceramic composite electrolyte is provided containing lithium nitride and lithium phosphate. The ceramic-ceramic composite is also preferably annealed and exhibits an activation energy of about 0.1 eV.

  14. Prevalence of Electrolyte Disorders Among Cases of Diarrhea with Severe Dehydration and Correlation of Electrolyte Levels with Age of the Patients

    International Nuclear Information System (INIS)

    Ahmad, M. S.; Wahid, A.; Ahmad, M.; Mahboob, N.; Mehmood, R.

    2016-01-01

    Objective: To find out the prevalence of electrolyte disorders among children with severe dehydration, and to study correlation between age and electrolyte, urea and creatinine levels. Study Design: Prospective, analytical study. Place and Duration of Study: Outdoor and indoor of Fazle-Omar Hospital, Rabwah, Pakistan, from January to December 2012. Methodology: All patients from birth to 18 years age, presenting with diarrhea and severe dehydration were included in the study. Urea, creatinine and electrolyte levels of all patients included in the study were checked and recorded in the data form with name, age and outcome. The prevalence of electrolyte disorders were ascertained and correlation with age was determined by Pearson's coefficient. Result: At total of 104 patients were included in the study. None of the patients died. Hyperchloremia was the commonest electrolyte disorder (53.8 percentage), followed by hyperkalemia (26.9 percentage) and hypernatremia (17.3 percentage). Hyponatremia, hypokalemia and hypochloremia were present in 10.6 percentage, 7.7 percentage, and 10.6 percentage cases, respectively. Weak negative correlation was found between age and chloride and potassium levels. Conclusion: Different electrolyte disorders are common in children with diarrhea-related severe dehydration. (author)

  15. An elevated serum alkaline phosphatase level in hepatic metastases of grade 1 and 2 gastrointestinal neuroendocrine tumors is unusual and of prognostic value.

    Directory of Open Access Journals (Sweden)

    Maeva Andriantsoa

    Full Text Available In our clinical practice we have observed that despite a high hepatic metastatic tumor burden, serum alkaline phosphatase (AP levels are frequently normal in cases of metastatic neuroendocrine tumor (NET.We retrospectively reviewed the records of patients with grade 1 and 2 NETs with liver metastases but without bone metastases seen at our institution in 2013. In total, 49 patients were included (22 female, with a median age of 60 years (range: 28 to 84 years. The primary tumors were located in the duodenum/pancreas (n = 29, small bowel (n = 17 or colon/rectum (n = 3; 10 cases were grade 1 and 39 grade 2. Hepatic involvement was bulky, with more than 10 lesions in 23 patients and a tumor burden above 10% of the liver volume in 26 patients.Serum AP levels were elevated (≥ upper limit of normal (ULN in 16 patients. In multiparametric analysis, elevated serum AP levels were not associated with the primary site, grade, or number or volume of metastases. In multiparametric analysis, progression-free survival was only correlated with grade (p = 0.010 and AP level (p = 0.017.Serum AP levels are frequently normal in liver metastases from NET, even in the event of a major tumor burden, and the serum AP level can be of prognostic value.

  16. Double electrolyte sensor for monitoring hydrogen permeation rate in steels

    International Nuclear Information System (INIS)

    Ouyang, Y.J.; Yu, G.; Ou, A.L.; Hu, L.; Xu, W.J.

    2011-01-01

    Highlights: → Designed an amperometric hydrogen sensor with double electrolytes. → Explained the principle of determining hydrogen permeation rate. → Verified good stability, reproducibility and correctness of the developed sensor. → Field on-line monitoring the susceptivity of hydrogen induced cracks. - Abstract: An amperometric hydrogen sensor with double electrolytes composed of a gelatiniform electrolyte and KOH solution has been developed to determine the permeation rate of hydrogen atoms in steel equipment owing to hydrogen corrosion. The gelatiniform electrolyte was made of sodium polyacrylate (PAAS), carboxyl methyl cellulose (CMC) and 0.2 mol dm -3 KOH solution. The results show that the gelatiniform electrolyte containing 50 wt.% polymers has suitable viscosity and high electrical conductivity. The consistent permeation curves were detected by the sensor of the double electrolyte and single liquid KOH electrolyte, respectively. The developed sensor has good stability and reproducibility at room temperature.

  17. Double electrolyte sensor for monitoring hydrogen permeation rate in steels

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Y.J. [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Department of Chemistry and Chemical Engineering, Huaihua College, Huaihua 418008 (China); Yu, G., E-mail: yuganghnu@163.co [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Ou, A.L.; Hu, L.; Xu, W.J. [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China)

    2011-06-15

    Highlights: {yields} Designed an amperometric hydrogen sensor with double electrolytes. {yields} Explained the principle of determining hydrogen permeation rate. {yields} Verified good stability, reproducibility and correctness of the developed sensor. {yields} Field on-line monitoring the susceptivity of hydrogen induced cracks. - Abstract: An amperometric hydrogen sensor with double electrolytes composed of a gelatiniform electrolyte and KOH solution has been developed to determine the permeation rate of hydrogen atoms in steel equipment owing to hydrogen corrosion. The gelatiniform electrolyte was made of sodium polyacrylate (PAAS), carboxyl methyl cellulose (CMC) and 0.2 mol dm{sup -3} KOH solution. The results show that the gelatiniform electrolyte containing 50 wt.% polymers has suitable viscosity and high electrical conductivity. The consistent permeation curves were detected by the sensor of the double electrolyte and single liquid KOH electrolyte, respectively. The developed sensor has good stability and reproducibility at room temperature.

  18. Ionic liquid-nanoparticle hybrid electrolytes

    KAUST Repository

    Lu, Yingying

    2012-01-01

    We investigate physical and electrochemical properties of a family of organic-inorganic hybrid electrolytes based on the ionic liquid 1-methyl-3-propylimidazolium bis(trifluoromethanesulfone) imide covalently tethered to silica nanoparticles (SiO 2-IL-TFSI). The ionic conductivity exhibits a pronounced maximum versus LiTFSI composition, and in mixtures containing 13.4 wt% LiTFSI, the room-temperature ionic conductivity is enhanced by over 3 orders of magnitude relative to either of the mixture components, without compromising lithium transference number. The SiO 2-IL-TFSI/LiTFSI hybrid electrolytes are thermally stable up to 400°C and exhibit tunable mechanical properties and attractive (4.25V) electrochemical stability in the presence of metallic lithium. We explain these observations in terms of ionic coupling between counterion species in the mobile and immobile (particle-tethered) phases of the electrolytes. © 2012 The Royal Society of Chemistry.

  19. A QuaternaryPoly(ethylene carbonate)-Lithium Bis(trifluoromethanesulfonyl)imide-Ionic Liquid-Silica Fiber Composite Polymer Electrolyte for Lithium Batteries

    International Nuclear Information System (INIS)

    Kimura, Kento; Matsumoto, Hidetoshi; Hassoun, Jusef; Panero, Stefania; Scrosati, Bruno; Tominaga, Yoichi

    2015-01-01

    Highlights: • A quaternary PEC-LiTFSI-Pyr 14 TFSI-Silica fiber electrolyte was prepared by a solvent casting method. • Both electrochemical and mechanical properties were improved by the presence of the Silica fiber. • The electrolyte showed a t Li+ value of 0.36 with an anodic stability extended up to 4.5 V vs. Li/Li + . • A prototype Li/LiFePO 4 polymer cell delivered a discharge capacity of about 100 mAh g −1 (75 °C, C/15). - Abstract: Poly(ethylene carbonate) (PEC) is known as an alternating copolymer derived from carbon dioxide (CO 2 ) and an epoxide as monomers. Here, we describe a new quaternary PEC-based composite electrolyte containing lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) salt, N-n-butyl-N-methylpyrrolidinium bis(trifluoromethanesulfonyl) imide (Pyr 14 TFSI) ionic liquid, and an electrospun silica (SiO 2 ) fiber (SiF) with a submicron diameter in view of its possible applications in solid-state Li polymer batteries. A free-standing electrolyte membrane is prepared by a solvent casting method. The Pyr 14 TFSI ionic liquid enhances the ionic conductivity of the electrolyte as a result of its plasticizing effect. The electrochemical properties, such as ionic conductivity and Li transference number (t Li+ ), as well as mechanical strength of the electrolyte, are further improved by the SiF. We show that the quaternary electrolyte has a conductivity of the order of 10 −7 S cm −1 at ambient temperature and a high t Li+ value of 0.36 with an excellent flexibility. A prototype Li polymer cell using LiFePO 4 as a cathode material is assembled and tested. We demonstrate that this battery delivers a reversible charge-discharge capacity close to 100 mAh g −1 at 75 °C and C/15 rate. We believe that this work may pave the road to utilize CO 2 as a carbon source for highly-demanded, functional battery materials in future

  20. Dense garnet-like Li5La3Nb2O12 solid electrolyte prepared by self-consolidation method

    Science.gov (United States)

    Zhao, Pengcheng; Xiang, Yu; Xu, Yan; Wen, Yuehua; Zhang, Wenfeng; Zhu, Xiayu; Li, Meng; Zhang, Sontong; Ming, Hai; Jin, Zhaoqing; Cao, Gaoping

    2018-06-01

    Li5La3Nb2O12 (LLNO) is a typical garnet-like solid electrolyte with solitary cubic structure. However, its ionic conductivity is relatively low due to the low relative density when prepared by cold isostatic pressing method, which usually involves high-pressure machines, poor productivity, tedious pressing operations, and low density. In this paper, self-consolidation method is developed to sinter dense LLNO electrolyte. Although not any pressing operations are employed in the entire process, the relative density of LLNO is promoted up to 95%, which is much higher than the reported values of 45-80%. SEM images reveal that the sample is built by huge particles in size of 80 μm indicating that there are few boundaries in the sample. Moreover, a rich content of Li-Al-O compounds is detected out in the boundary areas, which may act as sintering aids for the sample to consolidate automatically. According to the highest density, the bulk ionic conductivity of LLNO sample reaches up to 1.61 × 10-4 S cm-1 at 30 °C, which is in the same order of magnitude as the value of cubic Li7La3Zr2O12 electrolyte. This work verifies the self-consolidation mechanism for the sintering of ceramic electrolytes and could significantly facilitate the development of LLNO membrane technology.

  1. Device for equalizing molten electrolyte content in a fuel cell stack

    Science.gov (United States)

    Smith, J.L.

    1985-12-23

    A device for equalizing the molten electrolyte content throughout the height of a fuel cell stack is disclosed. The device includes a passageway for electrolyte return with electrolyte wettable wicking material in the opposite end portions of the passageway. One end portion is disposed near the upper, negative end of the stack where electrolyte flooding occurs. The second end portion is placed near the lower, positive end of the stack where electrolyte is depleted. Heating means are provided at the upper portion of the passageway to increase electrolyte vapor pressure in the upper wicking material. The vapor is condensed in the lower passageway portion and conducted as molten electrolyte in the lower wick to the positive end face of the stack. An inlet is provided to inject a modifying gas into the passageway and thereby control the rate of electrolyte return.

  2. Fluid and Electrolyte Disturbances in Critically Ill Patients

    OpenAIRE

    Lee, Jay Wook

    2010-01-01

    Disturbances in fluid and electrolytes are among the most common clinical problems encountered in the intensive care unit (ICU). Recent studies have reported that fluid and electrolyte imbalances are associated with increased morbidity and mortality among critically ill patients. To provide optimal care, health care providers should be familiar with the principles and practice of fluid and electrolyte physiology and pathophysiology. Fluid resuscitation should be aimed at restoration of normal...

  3. Influence of electrolyte nature on steel membrane hydrogen permeability

    International Nuclear Information System (INIS)

    Lisovskij, A.P.; Nazarov, A.P.; Mikhajlovskij, Yu.N.

    1993-01-01

    Effect of electrolyte nature on hydrogen absorption of carbonic steel membrane at its cathode polarization is studied. Electrolyte buffering by anions of subdissociated acids is shown to increase hydrogen flow though the membrane in acid electrolytes. Mechanisms covering dissociation of proton-bearing anion in the electrolyte near-the-electron layer or dissociative adsorption on steel surface are suggested. Effect of proton-bearing bases forming stable complex compounds with iron, is studied. Activation of anode process of iron solution is shown to increase the rate of hydrogen penetration

  4. Low temperature electrochemistry at normal conductor/frozen electrolyte interface

    International Nuclear Information System (INIS)

    Borkowska, Z.; Stimming, U.

    1991-01-01

    The frozen electrolyte technique (FREECE = FRozen Electrolyte ElectroChEmistry) is based on the experimental result that frozen electrolytes are suitable for electrochemical studies. This technique has been used in our laboratory and also by others to investigate interfacial electrochemical behavior. An argument will be given as to why the FREECE technique is advantageous in a number of respects and what kind of electrolyte systems can be used. Reference is made to electrochemical results such as interfacial reactions and double layer properties. 26 refs

  5. MultiLayer solid electrolyte for lithium thin film batteries

    Science.gov (United States)

    Lee, Se -Hee; Tracy, C. Edwin; Pitts, John Roland; Liu, Ping

    2015-07-28

    A lithium metal thin-film battery composite structure is provided that includes a combination of a thin, stable, solid electrolyte layer [18] such as Lipon, designed in use to be in contact with a lithium metal anode layer; and a rapid-deposit solid electrolyte layer [16] such as LiAlF.sub.4 in contact with the thin, stable, solid electrolyte layer [18]. Batteries made up of or containing these structures are more efficient to produce than other lithium metal batteries that use only a single solid electrolyte. They are also more resistant to stress and strain than batteries made using layers of only the stable, solid electrolyte materials. Furthermore, lithium anode batteries as disclosed herein are useful as rechargeable batteries.

  6. Method of electrolytic decontamination of contaminated metal materials for radioactivity

    International Nuclear Information System (INIS)

    Harada, Yoshio; Ishibashi, Masaru; Matsumoto, Hiroyo.

    1985-01-01

    Purpose: To electrolytically eliminate radioactive materials from metal materials contaminated with radioactive materials, as well as efficiently remove metal ions leached out in an electrolyte. Method: In the case of anodic dissolution of metal materials contaminated with radioactivity in an electrolyte to eliminate radioactive contaminating materials on the surface of the metal materials, a portion of an electrolytic cell is defined with partition membranes capable of permeating metal ions therethrough. A cathode connected to a different power source is disposed to the inside of the partition membranes and fine particle of metals are suspended and floated in the electrolyte. By supplying an electric current between an insoluble anode disposed outside of the partition membranes and the cathode, metal ions permeating from the outside of the partition membranes are deposited on the fine metal particles. Accordingly, since metal ions in the electrolyte are removed, the electrolyte can always be kept clean. (Yoshihara, H.)

  7. Exploring electrolyte preference of vanadium nitride supercapacitor electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Bo; Chen, Zhaohui; Lu, Gang [Department of Electrical Engineering and Automation, Luoyang Institute of Science and Technology, Luoyang 471023 (China); Wang, Tianhu [School of Electrical Information and Engineering, Jiangsu University of Technology, Changzhou 213001 (China); Ge, Yunwang, E-mail: ywgelit@126.com [Department of Electrical Engineering and Automation, Luoyang Institute of Science and Technology, Luoyang 471023 (China)

    2016-04-15

    Highlights: • Hierarchical VN nanostructures were prepared on graphite foam. • Electrolyte preference of VN supercapacitor electrodes was explored. • VN showed better capacitive property in organic and alkaline electrolytes than LiCl. - Abstract: Vanadium nitride hierarchical nanostructures were prepared through an ammonia annealing procedure utilizing vanadium pentoxide nanostructures grown on graphite foam. The electrochemical properties of hierarchical vanadium nitride was tested in aqueous and organic electrolytes. As a result, the vanadium nitride showed better capacitive energy storage property in organic and alkaline electrolytes. This work provides insight into the charge storage process of vanadium nitride and our findings can shed light on other transition metal nitride-based electrochemical energy storage systems.

  8. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  9. Benchmarking of electrolyte mass transport in next generation lithium batteries

    Directory of Open Access Journals (Sweden)

    Jonas Lindberg

    2017-12-01

    Full Text Available Beyond conductivity and viscosity, little is often known about the mass transport properties of next generation lithium battery electrolytes, thus, making performance estimation uncertain when concentration gradients are present, as conductivity only describes performance in the absence of these gradients. This study experimentally measured the diffusion resistivity, originating from voltage loss due to a concentration gradient, together with the ohmic resistivity, obtained from ionic conductivity measurements, hence, evaluating electrolytes both with and without the presence of concentration gradients. Under galvanostatic conditions, the concentration gradients, of all electrolytes examined, developed quickly and the diffusion resistivity rapidly dominated the ohmic resistivity. The electrolytes investigated consisted of lithium salt in: room temperature ionic liquids (RTIL, RTIL mixed organic carbonates, dimethyl sulfoxide (DMSO, and a conventional Li-ion battery electrolyte. At steady state the RTIL electrolytes displayed a diffusion resistivity ~ 20 times greater than the ohmic resistivity. The DMSO-based electrolyte showed mass transport properties similar to the conventional Li-ion battery electrolyte. In conclusion, the results presented in this study show that the diffusion polarization must be considered in applications where high energy and power density are desired.

  10. The value of combined examination of serum CYFRA21-1 levels and bone scan in the diagnosis of bone metastasis in lung cancer

    International Nuclear Information System (INIS)

    Yu Jing; Wang Junhong; Zhengping

    2007-01-01

    Objective: To explore the value of combined examination of serum tumor markers CYFRA21-1 and bone scan in the diagnosis of bone metastasis in lung cancer. Methods: Bone scan and serum CYFRA21-1 levels (with CLIA) determination were performed in 138 patients with lung cancer and 56 patients with benign lung diseases. Results: The serum level of CYFRA21-1 were significantly higher in patients with bone metastasis than those in patients without bone metastasis. The levels were also higher in patients without bone metastasis than those in controls. Most patients with bone metastasis had positive results in bone scan (97.4%), only 2 of the 78 had negative bone scan but positive with CT or MRI. A few patients without bone metastasis and controls had positive bone scan results, caused by previous operation or injury. Conclusion: The combined detection of CYFRA21-1 and bone scan were valuable in the diagnosis of bone metastasis of lung cancer. (authors)

  11. Ionic Liquid Catalyzed Electrolyte for Electrochemical Polyaniline Supercapacitors

    Science.gov (United States)

    Inamdar, A. I.; Im, Hyunsik; Jung, Woong; Kim, Hyungsang; Kim, Byungchul; Yu, Kook-Hyun; Kim, Jin-Sang; Hwang, Sung-Min

    2013-05-01

    The effect of different wt.% of ionic liquid "1,6-bis (trimethylammonium-1-yl) hexane tetrafluoroborate" in 0.5 M LiClO4+PC electrolyte on the supercapacitor properties of polyaniline (PANI) thin film are investigated. The PANI film is synthesized using electropolymerization of aniline in the presence of sulfuric acid. The electrochemical properties of the PANI thin film are studied by cyclic voltammetry, galvanostatic charge-discharge and electrochemical impedance spectroscopy (EIS) measurements. The optimum amount of the ionic liquid is found to be 2 wt.% which provides better ionic conductivity of the electrolyte. The highest specific capacitance of 259 F/g is obtained using the 2 wt.% electrolyte. This capacitance remains at up to 208 F/g (80% capacity retention) after 1000 charge-discharge cycles at a current density of 0.5 mA/g. The PANI film in the 2 wt.% ionic liquid catalyzed 0.5 M LiClO4+PC electrolyte shows small electrochemical resistance, better rate performance and higher cyclability. The increased ionic conductivity of the 2 wt.% ionic liquid catalyzed electrolyte causes a reduction in resistance at the electrode/electrolyte interface, which can be useful in electrochemically-preferred power devices for better applicability.

  12. Quantum dot doped solid polymer electrolyte for device application

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Pramod K.; Kim, Kang Wook; Rhee, Hee-Woo [Department of Chemical and Biomolecular Engineering, Sogang University, Mapo-Gu, Seoul 121-742 (Korea)

    2009-06-15

    ZnS capped CdSe quantum dots embedded in PEO:KI:I{sub 2} polymer electrolyte matrix have been synthesized and characterized for dye sensitized solar cell (DSSC) application. The complex impedance spectroscopy shows enhance in ionic conductivity ({sigma}) due to charges provide by quantum dots (QD) while AFM affirm the uniform distribution of QD into polymer electrolyte matrix. Cyclic voltammetry revealed the possible interaction between polymer electrolyte, QD and iodide/iodine. The photovoltaic performances of the DSSC containing quantum dots doped polymer electrolyte was also found to improve. (author)

  13. Electrocatalysis of fuel cell reactions: Investigation of alternate electrolytes

    Science.gov (United States)

    Chin, D. T.; Hsueh, K. L.; Chang, H. H.

    1984-01-01

    Oxygen reduction and transport properties of the electrolyte in the phosphoric acid fuel cell are studied. The areas covered were: (1) development of a theoretical expression for the rotating ring disk electrode technique; (2) determination of the intermediate reaction rate constants for oxygen reduction on platinum in phosphoric acid electrolyte; (3) determination of oxygen reduction mechanism in trifluoreomethanesulfonic acid (TFMSA) which was considered as an alternate electrolyte for the acid fuel cells; and (4) the measurement of transport properties of the phosphoric acid electrolyte at high concentrations and temperatures.

  14. Wide-Temperature Electrolytes for Lithium-Ion Batteries.

    Science.gov (United States)

    Li, Qiuyan; Jiao, Shuhong; Luo, Langli; Ding, Michael S; Zheng, Jianming; Cartmell, Samuel S; Wang, Chong-Min; Xu, Kang; Zhang, Ji-Guang; Xu, Wu

    2017-06-07

    Formulating electrolytes with solvents of low freezing points and high dielectric constants is a direct approach to extend the service-temperature range of lithium (Li)-ion batteries (LIBs). In this study, we report such wide-temperature electrolyte formulations by optimizing the ethylene carbonate (EC) content in the ternary solvent system of EC, propylene carbonate (PC), and ethyl methyl carbonate (EMC) with LiPF 6 salt and CsPF 6 additive. An extended service-temperature range from -40 to 60 °C was obtained in LIBs with lithium nickel cobalt aluminum oxide (LiNi 0.80 Co 0.15 Al 0.05 O 2 , NCA) as cathode and graphite as anode. The discharge capacities at low temperatures and the cycle life at room temperature and elevated temperatures were systematically investigated together with the ionic conductivity and phase-transition behaviors. The most promising electrolyte formulation was identified as 1.0 M LiPF 6 in EC-PC-EMC (1:1:8 by wt) with 0.05 M CsPF 6 , which was demonstrated in both coin cells of graphite∥NCA and 1 Ah pouch cells of graphite∥LiNi 1/3 Mn 1/3 Co 1/3 O 2 . This optimized electrolyte enables excellent wide-temperature performances, as evidenced by the high capacity retention (68%) at -40 °C and C/5 rate, significantly higher than that (20%) of the conventional LIB electrolyte, and the nearly identical stable cycle life as the conventional LIB electrolyte at room temperature and elevated temperatures up to 60 °C.

  15. Alkaline direct ethanol fuel cell performance using alkali-impregnated polyvinyl alcohol/functionalized carbon nano-tube solid electrolytes

    Science.gov (United States)

    Huang, Chien-Yi; Lin, Jia-Shiun; Pan, Wen-Han; Shih, Chao-Ming; Liu, Ying-Ling; Lue, Shingjiang Jessie

    2016-01-01

    This study investigates the application of a polyvinyl alcohol (PVA)/functionalized carbon nano-tubes (m-CNTs) composite in alkaline direct ethanol fuel cells (ADEFC). The m-CNTs are functionalized with PVA using the ozone mediation method, and the PVA composite containing the modified CNTs is prepared. Adding m-CNT into the PVA matrix enhances the alkaline uptake and the ionic conductivity of the KOH-doped electrolyte. Meanwhile, the m-CNT-containing membrane exhibited a lower swelling ratio and suppressed ethanol permeability compared to the pristine PVA film. The optimal condition for the ADEFC is determined to be under operation at an anode feed of 3 M ethanol in a 5 M KOH solution (at a flow rate of 5 cm3 min-1) with a cathode feed of moisturized oxygen (with a flow rate of 100 cm3 min-1) and the KOH-doped PVA/m-CNT electrolyte. We achieved a peak power density value of 65 mW cm-2 at 60 °C, which is the highest among the ADEFC literature data and several times higher than the proton-exchange direct ethanol fuel cells using sulfonated membrane electrolytes. Therefore, the KOH-doped PVA/m-CNT electrolyte is a suitable solid electrolyte for ADEFCs and has potential for commercialization in alkaline fuel cell applications.

  16. Clinical value of combined measurement of serum alpha-fetoprotein, alpha-L-fucosidase and ferritin levels in the diagnosis of primary liver cancer

    International Nuclear Information System (INIS)

    Zhang Aimin; Chai Xiaohong; Jin Ying; Dong Xuemei

    2005-01-01

    Objective: To investigate the clinical value of combined measurement of serum alpha-fetoprotein (AFP), alpha-L-fucosidase (AFU) and ferritin (SF) levels in the diagnosis of primary liver cancer. Methods: Serum AFP, AFU (with RIA) and SF (with biochemical method) were determined in 52 patients with primary liver cancer and 40 controls. Results: The positive rates of AFP, AFU and SF in patient with liver cancer were 82.7%, 86.6% and 76.9%, respectively. Positive rates with combined measurement of AFP plus AFU, AFP plus SF, and AFP plus AFU, SF were 94.2%, 90.4% and 98.1% respectively. Conclusion: Combined measurement of AFP, AFU and SF can significantly increase the positive rate in the diagnosis of primary liver cancer. (authors)

  17. UV-Induced Radical Photo-Polymerization: A Smart Tool for Preparing Polymer Electrolyte Membranes for Energy Storage Devices

    Directory of Open Access Journals (Sweden)

    Claudio Gerbaldi

    2012-06-01

    Full Text Available In the present work, the preparation and characterization of quasi-solid polymer electrolyte membranes based on methacrylic monomers and oligomers, with the addition of organic plasticizers and lithium salt, are described. Noticeable improvements in the mechanical properties by reinforcement with natural cellulose hand-sheets or nanoscale microfibrillated cellulose fibers are also demonstrated. The ionic conductivity of the various prepared membranes is very high, with average values approaching 10-3 S cm-1 at ambient temperature. The electrochemical stability window is wide (anodic breakdown voltages > 4.5 V vs. Li in all the cases along with good cyclability in lithium cells at ambient temperature. The galvanostatic cycling tests are conducted by constructing laboratory-scale lithium cells using LiFePO4 as cathode and lithium metal as anode with the selected polymer electrolyte membrane as the electrolyte separator. The results obtained demonstrate that UV induced radical photo-polymerization is a well suited method for an easy and rapid preparation of easy tunable quasi-solid polymer electrolyte membranes for energy storage devices.

  18. UV-Induced Radical Photo-Polymerization: A Smart Tool for Preparing Polymer Electrolyte Membranes for Energy Storage Devices

    Directory of Open Access Journals (Sweden)

    Claudio Gerbaldi

    2012-10-01

    Full Text Available In the present work, the preparation and characterization of quasi-solid polymer electrolyte membranes based on methacrylic monomers and oligomers, with the addition of organic plasticizers and lithium salt, are described. Noticeable improvements in the mechanical properties by reinforcement with natural cellulose hand-sheets or nanoscale microfibrillated cellulose fibers are also demonstrated. The ionic conductivity of the various prepared membranes is very high, with average values approaching 10-3 S cm-1 at ambient temperature. The electrochemical stability window is wide (anodic breakdown voltages > 4.5 V vs. Li in all the cases along with good cyclability in lithium cells at ambient temperature. The galvanostatic cycling tests are conducted by constructing laboratory-scale lithium cells using LiFePO4 as cathode and lithium metal as anode with the selected polymer electrolyte membrane as the electrolyte separator. The results obtained demonstrate that UV induced radical photo-polymerization is a well suited method for an easy and rapid preparation of easy tunable quasi-solid polymer electrolyte membranes for energy storage devices.

  19. Relationship between surface tension and refractive index in binary non-electrolyte mixtures

    International Nuclear Information System (INIS)

    Acevedo, I.L.; Pedrosa, G.C.; Katz, M.

    1990-01-01

    Lorentz-Lorenz equation for molecular refraction has been combined with Sugden's parachor equation for binary non-electrolyte mixtures at 298.15 K. The obtained equation has been shown successful in calculating values of surface tensions, by measuring refractive indices of the binary mixtures at the same mole fractions. The estimated error decreases when the mixtures present possible isorefractives. (Author) [es

  20. Lithium-ion batteries having conformal solid electrolyte layers

    Science.gov (United States)

    Kim, Gi-Heon; Jung, Yoon Seok

    2014-05-27

    Hybrid solid-liquid electrolyte lithium-ion battery devices are disclosed. Certain devices comprise anodes and cathodes conformally coated with an electron insulating and lithium ion conductive solid electrolyte layer.