WorldWideScience

Sample records for serum ecf tests

  1. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  2. Characterization of five ECF sigma factors in the genome of Pseudomonas syringae pv. syringae B728a.

    Directory of Open Access Journals (Sweden)

    Poulami Basu Thakur

    Full Text Available Pseudomonas syringae pv. syringae B728a, a bacterial pathogen of bean, utilizes large surface populations and extracellular signaling to initiate a fundamental change from an epiphytic to a pathogenic lifestyle. Extracytoplasmic function (ECF sigma (σ factors serve as important regulatory factors in responding to various environmental signals. Bioinformatic analysis of the B728a genome revealed 10 ECF sigma factors. This study analyzed deletion mutants of five previously uncharacterized ECF sigma factor genes in B728a, including three FecI-type ECF sigma factors (ECF5, ECF6, and ECF7 and two ECF sigma factors placed in groups ECF11 and ECF18. Transcriptional profiling by qRT-PCR analysis of ECF sigma factor mutants was used to measure expression of their associated anti-sigma and outer membrane receptor proteins, and expression of genes associated with production of extracellular polysaccharides, fimbriae, glycine betaine and syringomycin. Notably, the B728aΔecf7 mutant displayed reduced swarming and had decreased expression of CupC fimbrial genes. Growth and pathogenicity assays, using a susceptible bean host, revealed that none of the tested sigma factor genes are required for in planta growth and lesion formation.

  3. Improvement of Output Power of ECF Micromotor

    Science.gov (United States)

    Yokota, Shinichi; Kawamura, Kiyomi; Takemura, Kenjiro; Edamura, Kazuya

    Electro-conjugate fluid (ECF) is a kind of dielectric fluids, which produces jet-flow (ECF jet) when subjected to a high DC voltage. By using the ECF jet, a new type of micromotor with simple structure and lightweight can be realized. Up to now, we developed a disk-plate type ECF micromotor with inner diameter of 9 mm. In this study, we develope novel ECF micromotors with inner diameter of 5 mm in order to improve the output power density. First, we designed and produced the ECF micromotors with 4-layered and 8-layered disk plate rotors. Then, the performances of the motors are measured. The experimental results confirm the motor developed has a higher performance than the previous ones.

  4. Serum leptin and insulin tests in obesity

    International Nuclear Information System (INIS)

    Yang Yin; Jiang Xiaojin; Leng Xiumei

    2001-01-01

    Objective: To study the clinical significance and the relations of leptin and insulin on obesity group. Methods: Leptin and insulin were tested with radioimmunoassay (RIA) in pre-obesity group and obesity group respectively. Results: Serum leptin and insulin levels were significantly elevated in obesity group compare with the controls (P<0.01). Conclusion: Changing with insulin, the elevation of leptin in obesity group has been identified as an important agent of diabetes mellitus (DM)

  5. Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Sarit Badiani, Sarit; Karandikar, Sharad [Dept. of General Surgery, Heart of England Foundation Trust, Birmingham (United Kingdom); Tomas-Hernandez, Silvia; Roy-Choudhury; Shuvro [Dept. of Radiology, Heart of England Foundation Trust, Birmingham (United Kingdom)], e-mail: shurvrorc@googlemail.com

    2013-10-15

    Background: Computed tomographic colonography (CTC) is now an established method for imaging the colon and rectum in the screening and symptomatic setting. Additional benefit of CTC is the ability to assess for extracolonic findings especially in patients presenting with colorectal symptoms. Purpose: To determine prevalence of extracolonic findings (ECF) in symptomatic patients undergoing CTC and determine accuracy of CTC for exclusion of significant abdominal disease and extracolonic malignancy (ECM). Material and Methods: A total of 1359 unenhanced prone and postcontrast supine CTC studies were performed between March 2002 and December 2007. ECF were retrospectively classified according to C-RADS criteria into E1 to E4 findings. For ECM, a gold standard of clinical and/or radiological follow-up supplemented with data from the regional cancer registry with a median follow-up of 42 months was created. Sensitivity and negative predictive values for ECM was calculated. Results: Following exclusions, 1177 CTCs were analyzed. Of 1423 extracolonic findings reported, 328/1423 (23%) E3 and 100/1423 (7%) E4 (including six eventual FP studies) findings were identified. Thirty-two ECMs were confirmed following further investigations. Seven further small ECMs were detected during the entire follow-up, of which two were potentially visible in retrospect (false-negative studies). Additional tests were generated from 55/1177 (4.7%) studies. Sensitivity and negative predictive value for ECM was 94.1% (95% CI 78.9 - 98.9%) and 99.8% (95% CI 99.3 - 99.9%), respectively. Conclusion: One in 37 patients were found to have an ECM. Two potentially detectable cancers were missed. Only a small proportion of patients underwent additional work-up.

  6. Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms.

    Science.gov (United States)

    Badiani, Sarit; Tomas-Hernandez, Silvia; Karandikar, Sharad; Roy-Choudhury, Shuvro

    2013-10-01

    Computed tomographic colonography (CTC) is now an established method for imaging the colon and rectum in the screening and symptomatic setting. Additional benefit of CTC is the ability to assess for extracolonic findings especially in patients presenting with colorectal symptoms. To determine prevalence of extracolonic findings (ECF) in symptomatic patients undergoing CTC and determine accuracy of CTC for exclusion of significant abdominal disease and extracolonic malignancy (ECM). A total of 1359 unenhanced prone and postcontrast supine CTC studies were performed between March 2002 and December 2007. ECF were retrospectively classified according to C-RADS criteria into E1 to E4 findings. For ECM, a gold standard of clinical and/or radiological follow-up supplemented with data from the regional cancer registry with a median follow-up of 42 months was created. Sensitivity and negative predictive values for ECM was calculated. Following exclusions, 1177 CTCs were analyzed. Of 1423 extracolonic findings reported, 328/1423 (23%) E3 and 100/1423 (7%) E4 (including six eventual FP studies) findings were identified. Thirty-two ECMs were confirmed following further investigations. Seven further small ECMs were detected during the entire follow-up, of which two were potentially visible in retrospect (false-negative studies). Additional tests were generated from 55/1177 (4.7%) studies. Sensitivity and negative predictive value for ECM was 94.1% (95% CI 78.9-98.9%) and 99.8% (95% CI 99.3-99.9%), respectively. One in 37 patients were found to have an ECM. Two potentially detectable cancers were missed. Only a small proportion of patients underwent additional work-up.

  7. Micromotors making use of electric field conjugate fluid (ECF). Proposition for Re-type ECF micromotor and study of its miniaturized version performance by experiment; Denkai kyoeki ryutai (ECF) wo oyoshita micromotor. RE gata ECF micromotor no teian oyobi bishoka tokusei no jikkenteki kento

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Y.; Yokota, S.; Nemoto, T. [Tokyo Institute of Technology, Tokyo (Japan); Otsubo, Y. [Chiba University, Tokyo (Japan); Edamura, K.

    1999-01-15

    A stator electrode (SE)-type ECF micromotor and a rotor electrode (RE)-type ECF micromotor are proposed, and have been tentatively constructed, both making use of ECF in which a jet flow is generated upon application of an electrostatic field across line electrodes. At the beginning, experiments are conducted to establish relationship between the impressed voltage and the number of revolutions in the RE-type micromotor that is expected to generate more torque than the SE-type micromotor. Next, the RE-type micromotor is miniaturized, and experiments are conducted to study the changes in power density and efficiency brought about by miniaturization. (translated by NEDO)

  8. Testing of serum atherogenicity in cell cultures: questionable data published

    Directory of Open Access Journals (Sweden)

    Sergei V. Jargin

    2012-01-01

    Full Text Available In a large series of studies was reported that culturing of smooth muscle cells with serum from atherosclerosis patients caused intracellular lipid accumulation, while serum from healthy controls had no such effect. Cultures were used for evaluation of antiatherogenic drugs. Numerous substances were reported to lower serum atherogenicity: statins, trapidil, calcium antagonists, garlic derivatives etc. On the contrary, beta-blockers, phenothiazines and oral hypoglycemics were reported to be pro-atherogenic. Known antiatherogenic agents can influence lipid metabolism and cholesterol synthesis, intestinal absorption or endothelium-related mechanisms. All these targets are absent in cell monocultures. Inflammatory factors, addressed by some antiatherogenic drugs, are also not reproduced. In vivo, relationship between cholesterol uptake by cells and atherogenesis must be inverse rather than direct: in familial hypercholesterolemia, inefficient clearance of LDL-cholesterol by cells predisposes to atherosclerosis. Accordingly, if a pharmacological agent reduces cholesterol uptake by cells in vitro, it should be expected to elevate cholesterol in vivo. Validity of clinical recommendations, based on serum atherogenicity testing in cell monocultures, is therefore questionable. These considerations pertain also to the drugs developed on the basis of the cell culture experiments.

  9. Atmospheric chemistry of Z- and E-CF3CH=CHCF3

    DEFF Research Database (Denmark)

    Østerstrøm, Freja From; Andersen, Simone Thirstrup; Sølling, Theis Ivan

    2017-01-01

    radicals. The atmospheric lifetimes of Z- and E-CF3CH[double bond, length as m-dash]CHCF3 are estimated as 27 and 67 days, respectively. IR absorption cross sections are reported and the global warming potentials (GWPs) of Z- and E-CF3CH[double bond, length as m-dash]CHCF3 for the 100 year time horizon...

  10. Denitrification using a monopolar electrocoagulation/flotation (ECF) process.

    Science.gov (United States)

    Emamjomeh, Mohammad M; Sivakumar, Muttucumaru

    2009-01-01

    Nitrate levels are limited due to health concerns in potable water. Nitrate is a common contaminant in water supplies, and especially prevalent in surface water supplies and shallow wells. Nitrate is a stable and highly soluble ion with low potential for precipitation or adsorption. These properties make it difficult to remove using conventional water treatment methods. A laboratory batch electrocoagulation/flotation (ECF) reactor was designed to investigate the effects of different parameters such as electrolysis time, electrolyte pH, initial nitrate concentration, and current rate on the nitrate removal efficiency. The optimum nitrate removal was observed at a pH range of between 9 and 11. It appeared that the nitrate removal rate was 93% when the initial nitrate concentration and electrolysis time respectively were 100 mg L(-1)-NO(3)(-) and 40 min. The results showed a linear relationship between the electrolysis time for total nitrate removal and the initial nitrate concentration. It is concluded that the electrocoagulation technology for denitrification can be an effective preliminary process when the ammonia byproduct must be effectively removed by the treatment facilities.

  11. Mechanized toxicological serum tests in screening hospitalized patients.

    Science.gov (United States)

    Hallbach, J; Guder, W G

    1991-09-01

    A spectrum of quantitative and qualitative methods was adapted to the RA-1000/RA-XT selective analyser for the purpose of excluding or detecting common types of intoxication in the emergency laboratory of our primary care community hospital. Ethanol and salicylates (measured photometrically) and acetaminophen (measured immunologically by EMIT tox) were quantitatively analysed in serum. immunological group tests (EMIT tox) for barbiturates, benzodiazepines, tricyclic antidepressants and related compounds were used for qualitative analysis. Well established clinical chemical methods (aspartarte aminotransferase, alanine aminotransferase, creatine kinase, pseudocholinesterase, glucose and lactate) were applied to the serum samples using the same selective analyser. Within and between run precision, accuracy, recovery and detection ranges (linearity) fulfilled the recommendations of forefield toxicological analysis for all methods. Ethanol (g/l), measured photometrically with the RA-1000 analyser, agreed with the reference method (headspace gas-chromatography) with a correlation coefficient greater than 0.99 (y = 0.06 + 0.98x). Acetaminophen and salicylates showed correlation coefficients greater than 0.94 and greater than 0.99, when compared with manual colorimetric procedures (acetaminophen (mg/l): y = -3.22 + 0.896x; salicylates (mg/l): y = -2.1 + 1x). Qualitative group tests for barbiturates, benzodiazepines and tricyclic antidepressants measured with the RA-1000 analyser were in good agreement with the EMIT single test procedure. The ranges of the quantitative methods allowed quantification of analytes from therapeutic (non-toxic) to very high levels in undiluted samples (ethanol 0.05 up to 4 g/l; salicylates 32 up to 1200 mg/l and acetaminophen 1.9 up to 200 mg/l). The low detection limits of the qualitative tests allowed the recognition of compounds in plasma that were present in low concentrations and/or displayed only minor reactivity with the antibodies

  12. UV-LIGA technique for ECF micropumps using back UV exposure and self-alignment

    Science.gov (United States)

    Han, D.; Xia, Y.; Yokota, S.; Kim, J. W.

    2017-12-01

    This paper proposes and develops a novel UV-LIGA technique using back UV exposure and self-alignment to realize high aspect ratio micromachining (HARM) in high power density electro-conjugate fluid (ECF) micropumps. ECF is a functional fluid designed to be able to generate strong and active jet flow (ECF jetting) between anode and cathode in ECF when high DC voltage is applied. We have developed high power density ECF micropumps consisting of triangular prism and slit electrode pairs (TPSEs) fabricated by HARM. The traditional UV-LIGA technique for HARM is mainly divided into two approaches: (a) single thick layer and (b) multiple thin layers. Both methods have limitations—deformed molds in the former and misalignment between layers in the latter. Using the finite element method software COMSOL Multiphysics, we demonstrate that the deformed micro-molds critically impair the performance of ECF micropumps. In addition, we experimentally prove that the misalignment would easily trigger electric discharge in the ECF micropumps. To overcome these limitations, we conceive a new concept utilizing the seed electrode layer for electroforming as the UV shield and pattern photoresist (KMPR) by back UV exposure. The seed electrode layer should be composed of a non-transparent conductor (Au/Ti) for patterning and a transparent conductor (ITO) for wiring. Instead of ITO, we propose the concept of transparency-like electrodes comprised of thin metal line patterns. To verify this concept, KMPR layers with thicknesses of 70, 220, and 500 µm are experimentally investigated. In the case of 500 µm KMPR thickness, the concept of transparency-like electrode was partially proved. As a result, TPSEs with a height of 440 µm were successfully fabricated. Characteristic experiments demonstrated that ECF micropumps (367 mW cm-3) fabricated by back UV achieved almost the same output power density as ECF micropumps (391 mW cm-3) fabricated by front UV. This paper proves that the proposed

  13. UV-LIGA technique for ECF micropumps using back UV exposure and self-alignment

    International Nuclear Information System (INIS)

    Han, D; Xia, Y; Yokota, S; Kim, J W

    2017-01-01

    This paper proposes and develops a novel UV-LIGA technique using back UV exposure and self-alignment to realize high aspect ratio micromachining (HARM) in high power density electro-conjugate fluid (ECF) micropumps. ECF is a functional fluid designed to be able to generate strong and active jet flow (ECF jetting) between anode and cathode in ECF when high DC voltage is applied. We have developed high power density ECF micropumps consisting of triangular prism and slit electrode pairs (TPSEs) fabricated by HARM. The traditional UV-LIGA technique for HARM is mainly divided into two approaches: (a) single thick layer and (b) multiple thin layers. Both methods have limitations—deformed molds in the former and misalignment between layers in the latter. Using the finite element method software COMSOL Multiphysics, we demonstrate that the deformed micro-molds critically impair the performance of ECF micropumps. In addition, we experimentally prove that the misalignment would easily trigger electric discharge in the ECF micropumps. To overcome these limitations, we conceive a new concept utilizing the seed electrode layer for electroforming as the UV shield and pattern photoresist (KMPR) by back UV exposure. The seed electrode layer should be composed of a non-transparent conductor (Au/Ti) for patterning and a transparent conductor (ITO) for wiring. Instead of ITO, we propose the concept of transparency-like electrodes comprised of thin metal line patterns. To verify this concept, KMPR layers with thicknesses of 70, 220, and 500 µ m are experimentally investigated. In the case of 500 µ m KMPR thickness, the concept of transparency-like electrode was partially proved. As a result, TPSEs with a height of 440 µ m were successfully fabricated. Characteristic experiments demonstrated that ECF micropumps (367 mW cm −3 ) fabricated by back UV achieved almost the same output power density as ECF micropumps (391 mW cm −3 ) fabricated by front UV. This paper proves that the

  14. Detoxification of kraft pulp ECF bleaching effluents by catalytic hydrotreatment.

    Science.gov (United States)

    Calvo, L; Gilarranz, M A; Casas, J A; Mohedano, A F; Rodríguez, J J

    2007-02-01

    Two different effluents from the D(1) and E(1) stages of the ECF bleaching of Eucalyptus globulus kraft pulp were treated by catalytic hydrogenation in a trickle bed reactor using commercial and homemade Pd/AC catalysts. The reactor was fed with the bleaching effluent and a H(2)/N(2) gas stream. The variables studied were space-time (1.4-5g(cat)min/mL), gas to liquid flow ratio (286-1000vol.), gas feed concentration (H(2):N(2), 1:1-1:7.3vol.), temperature (25-100 degrees C) and pressure (1-11bar). Hydrotreatment performance was evaluated in terms of ecotoxicity, adsorbable organic halogen (AOX), chemical oxygen demand (COD), biological oxygen demand (BOD(5)) and colour removal. In all the runs, the ecotoxicity of the effluents decreased as a result of the treatment, achieving reductions that ranged from 70% to 98%. Simultaneously to the reduction of toxicity, the hydrotreatment led to a decrease of the colour of the effluents, being the decrease significantly higher in the case of E(1) effluent. The AOX content was reduced by 85% and 23% for E(1) and D(1) effluents, respectively. In the case of D(1) effluent the removal of ecotoxicity was significantly higher than that of AOX, which indicates that much of the toxicity of the effluent must be associated to non-chlorinated organics. In spite of the important reduction of ecotoxicity, the biodegradability of the effluents only increased slightly. The homemade catalysts, prepared from activated carbons with a high external or non-microporous surface area and mesopore volume and a convenient surface chemistry showed a higher efficiency than the commercial one.

  15. An Aromatic Cap Seals the Substrate Binding Site in an ECF-Type S Subunit for Riboflavin

    Energy Technology Data Exchange (ETDEWEB)

    Karpowich, Nathan K.; Song, Jinmei; Wang, Da-Neng

    2016-06-13

    ECF transporters are a family of active membrane transporters for essential micronutrients, such as vitamins and trace metals. Found exclusively in archaea and bacteria, these transporters are composed of four subunits: an integral membrane substrate-binding subunit (EcfS), a transmembrane coupling subunit (EcfT), and two ATP-binding cassette ATPases (EcfA and EcfA'). We have characterized the structural basis of substrate binding by the EcfS subunit for riboflavin from Thermotoga maritima, TmRibU. TmRibU binds riboflavin with high affinity, and the protein–substrate complex is exceptionally stable in solution. The crystal structure of riboflavin-bound TmRibU reveals an electronegative binding pocket at the extracellular surface in which the substrate is completely buried. Analysis of the intermolecular contacts indicates that nearly every available substrate hydrogen bond is satisfied. A conserved aromatic residue at the extracellular end of TM5, Tyr130, caps the binding site to generate a substrate-bound, occluded state, and non-conservative mutation of Tyr130 reduces the stability of this conformation. Using a novel fluorescence binding assay, we find that an aromatic residue at this position is essential for high-affinity substrate binding. Comparison with other S subunit structures suggests that TM5 and Loop5-6 contain a dynamic, conserved motif that plays a key role in gating substrate entry and release by S subunits of ECF transporters.

  16. Structure and Mechanism of the S Component of a Bacterial ECF Transporter

    Energy Technology Data Exchange (ETDEWEB)

    P Zhang; J Wang; Y Shi

    2011-12-31

    The energy-coupling factor (ECF) transporters, responsible for vitamin uptake in prokaryotes, are a unique family of membrane transporters. Each ECF transporter contains a membrane-embedded, substrate-binding protein (known as the S component), an energy-coupling module that comprises two ATP-binding proteins (known as the A and A' components) and a transmembrane protein (known as the T component). The structure and transport mechanism of the ECF family remain unknown. Here we report the crystal structure of RibU, the S component of the ECF-type riboflavin transporter from Staphylococcus aureus at 3.6-{angstrom} resolution. RibU contains six transmembrane segments, adopts a previously unreported transporter fold and contains a riboflavin molecule bound to the L1 loop and the periplasmic portion of transmembrane segments 4-6. Structural analysis reveals the essential ligand-binding residues, identifies the putative transport path and, with sequence alignment, uncovers conserved structural features and suggests potential mechanisms of action among the ECF transporters.

  17. Enhancement of Chlorella vulgaris harvesting via the electro-coagulation-flotation (ECF) method.

    Science.gov (United States)

    Wong, Y K; Ho, Y H; Leung, H M; Ho, K C; Yau, Y H; Yung, K K L

    2017-04-01

    This article explores the potential of using an electro-coagulation-flotation (ECF) harvester to allow flotation of microalgae cells for surface harvesting. A response surface methodology (RSM) model was used to optimize ECF harvesting by adjusting electrode plate material, electrode plate number, charge of the electrodes, electrolyte concentration, and pH value of the culture solution. The result revealed that three aluminum electrode plates (one anode and two cathodes), brine solution (8 g/L), and acidity (pH = 4) of culture solution (optimized ECF harvester) The highest flocculant concentration was measured at 2966 mg/L after 60 min and showed a 79.8 % increase of flocculation concentration. Such results can provide a basis for designing a large-scale microalgae harvester for commercial use in the future.

  18. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  19. Can serums be replaced by Mueller‑Hinton agar in germ tube test ...

    African Journals Online (AJOL)

    Background: The germ tube test (GTT) is inexpensive, easy, and well‑defined test that differentiates Candida albicans (excluding Candida dubliniensis and Candida africana) from other species. The aim of this study was to evaluate various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and ...

  20. Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.

    Science.gov (United States)

    Libert, Diane; Procop, Gary W; Ansari, Mohammad Q

    2018-03-07

    Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.

  1. Relationship between CT scans and serum tests for diagnosing tuberculosis

    International Nuclear Information System (INIS)

    Oliveira, Marcela de; Pina, Diana R.; Giacomini, Guilherme; Alvarez, Matheus; Pavan, Ana Luiza M.; Pereira, Paulo C.M.

    2014-01-01

    Tuberculosis (TB) is one of the oldest infectious diseases in the world and still affects humanity today. Since 1993, the World Health Organization (WHO) considers TB as a global emergency. The clinical history of the individual, the serum exams and particularly, the imaging examination of the thorax, are used for diagnostic confirmation and monitoring of disease. TB is a chronic disease that usually evolves with pulmonary sequelae that must be monitored. The exam of the image more precise to assess the radiological patterns found in these patients is high-resolution computed tomography (HRCT), which aids in medical diagnosis and permit the determination of the area affected by radiological abnormalities of pulmonary tuberculosis. The best known of such modifications by means of exams or more accurate techniques is of extreme importance. Therefore, this study aimed to show the quantification, performed by algorithms, of the areas affected by the radiological abnormalities of TB through the HRCT, and compared with serum exams. We studied 16 patients with confirmed diagnosis of TB. The serum exams evaluated included: hemoglobin, hematocrit, albumin, speed hemo sedimentation and C-reactive protein. With the values of serum exams we observed that patients have anemia, low albumin levels and inflammatory activity, corroborating imaging exams, which show severe impairment of lung area due to the inflammation caused by disease activity. (author)

  2. Evaluation of serum lysyl oxidase as a blood test for colorectal cancer.

    Science.gov (United States)

    Ward, S T; Weston, C J; Hepburn, E; Damery, S; Hejmadi, R K; Morton, D G; Middleton, G; Ismail, T; Adams, D H

    2014-06-01

    Lysyl oxidase (LOX) expression is elevated in colorectal cancer (CRC) tissue and associated with disease progression. A blood test may form a more acceptable diagnostic test for CRC although LOX has not previously been measured in the serum. We therefore sought to determine the clinical usefulness of a serum LOX test for CRC in a symptomatic population. Adult patients referred to a hospital colorectal clinic with bowel symptoms completed a questionnaire and provided a blood sample for serum LOX measurement. Associations between presenting symptoms, serum LOX concentrations and outcomes of investigations were tested by univariate and multivariate analyses to determine if serum LOX was clinically useful in the prediction of CRC. LOX expression in CRC and adjacent colon biopsies was evaluated by ELISA and immunohistochemistry. Thirty-one cases of colorectal cancer and 16 high-risk polyps were identified from a total of 962 participants. There was no association between serum LOX concentration and the presence of CRC, high-risk polyps or cancers at any site. LOX expression was significantly increased in CRC tissue compared to adjacent colon. Despite overexpression of LOX in CRC tissue, elevated serum levels could not be demonstrated. Serum LOX measurement is therefore not a clinically useful test for CRC. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  4. ' ORAL GLUCOSE-TOLERANCE TESTS AND SERUM INSULIN ...

    African Journals Online (AJOL)

    :s of the pellagra and kwashior- kor groups. on admission as well as after recovery, were compared with each other for significant differences at the 5°~ level of significance using variance analyses." The same tests were done in both groups to ...

  5. Three Good Reasons for Celebrating at the ESO/ST-ECF Science Archive Facility

    Science.gov (United States)

    2000-12-01

    Great Demand for Data from New "Virtual Observatory" Summary Due to a happy coincidence, the ESO/ST-ECF Science Archive Facility is celebrating three different milestones at the same time: * its 10th anniversary since the establishment in 1991 * the 10,000th request for data , and * the signing-up of active user number 2000 . This Archive contains over 8 Terabytes (1 Terabyte = 1 million million bytes) of valuable observational data from the NASA/ESA Hubble Space Telescope (HST), the ESO Very Large Telescope (VLT) and other ESO telescopes . Its success paves the way for the establishment of "Virtual Observatories" from which first-class data can be obtained by astronomers all over the world. This greatly enhances the opportunities for more (young) scientists to participate in front-line research. PR Photo 34/00 : Front-page of a new brochure, describing the ESO/ST-ECF Science Archive Facility. Just 10 years ago, on the 1st of January 1991, the ESO/ST-ECF (European Southern Observatory/Space Telescope-European Coordinating Facility) Science Archive Facility opened. It has since served the astronomical community with gigabyte after gigabyte of high-quality astronomical data from some of the world's leading telescopes. The Archive, which is located in Garching, just outside Munich (Germany), contains data from the 2.4-m NASA/ESA Hubble Space Telescope , as well as from several ESO telescopes: the four 8.2-m Unit Telescopes of the Very Large Telescope (VLT) at the Paranal Observatory , and the 3.5-m New Technology Telescope (NTT) , the 3.6-m telescope and the MPG/ESO 2.2-m telescope at La Silla. The Archive is a continuously developing project - in terms of amounts of data stored, the number of users and in particular because of the current dramatic development of innovative techniques for data handling and storage. In the year 2000 more than 2 Terabytes (2000 Gigabytes) of data were distributed to users worldwide. The archiving of VLT data has been described in ESO PR

  6. ECF2: A pulsed power generator based on magnetic flux compression for K-shell radiation production

    International Nuclear Information System (INIS)

    L'Eplattenier, P.; Lassalle, F.; Mangeant, C.; Hamann, F.; Bavay, M.; Bayol, F.; Huet, D.; Morell, A.; Monjaux, P.; Avrillaud, G.; Lalle, B.

    2002-01-01

    The 3 MJ energy stored ECF2 generator is developed at Centre d'Etudes de Gramat, France, for K-shell radiation production. This generator is based on microsecond LTD stages as primary generators, and on the magnetic flux compression scheme for power amplification from the microsecond to the 100ns regime. This paper presents a general overview of the ECF2 generator. The flux compression stage, a key component, will be studied in details. We will present its advantages and drawbacks. We will then present the first experimental and numerical results which show the improvements that have already been made on this scheme

  7. Serum progranulin concentrations are not responsive during oral lipid tolerance test and oral glucose tolerance test.

    Science.gov (United States)

    Schmid, A; Leszczak, S; Ober, I; Schäffler, A; Karrasch, T

    2015-07-01

    The postprandial regulation of progranulin by oral uptake of lipids and carbohydrates in healthy individuals has not yet been investigated. The regulation of progranulin in 2 large cohorts of healthy volunteers during oral lipid tolerance test (OLTT; n=100) and oral glucose tolerance test (OGTT; n=100) was analyzed. One hundred healthy volunteers underwent OLTT and OGTT in an outpatient setting. Venous blood was drawn at 0 hours (h) (fasting) and at 2, 4, and 6 h in OLTT or 1 and 2 h in OGTT. A novel OLTT solution completely free of carbohydrates and protein was applied. Subjects were characterized by anthropometric and laboratory parameters. Serum concentrations of progranulin were measured by enzyme-linked immunosorbent assay (ELISA). Circulating progranulin levels remained unchanged during OLTT and OGTT. Fasting progranulin levels ranged between 31.3±8.7 and 40.6±7.7 ng/ml and were not different in subgroups addressing BMI, gender, family history, smoking habits, and hormonal contraception. There was a reciprocal correlation of progranulin with HDL (negative) and LDL cholesterol levels (positive). In healthy adults, fasting and postprandial circulating progranulin levels are not different in BMI subgroups. Oral uptake of carbohydrates and lipids does not influence circulating progranulin levels in a short-term manner. A postprandial and short-term regulation of this adipokine is absent, at least in healthy subjects. There is a negative correlation of progranulin with HDL cholesterol, but a positive correlation with LDL cholesterol. This reciprocal association might be of physiological importance for an individual's atherosclerotic risk. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Evaluation of Serum Thyroid-Stimulating Hormone Concentration as a Diagnostic Test for Hyperthyroidism in Cats.

    Science.gov (United States)

    Peterson, M E; Guterl, J N; Nichols, R; Rishniw, M

    2015-01-01

    In humans, measurement of serum thyroid-stimulating hormone (TSH) concentration is commonly used as a first-line discriminatory test of thyroid function. Recent reports indicate that canine TSH (cTSH) assays can be used to measure feline TSH and results can help diagnose or exclude hyperthyroidism. To investigate the usefulness of cTSH measurements as a diagnostic test for cats with hyperthyroidism. Nine hundred and seventeen cats with untreated hyperthyroidism, 32 euthyroid cats suspected of having hyperthyroidism, and 131 clinically normal cats. Prospective study. Cats referred to the Animal Endocrine Clinic for suspected hyperthyroidism were evaluated with serum T4, T3, free T4 (fT4), and TSH concentrations. Thyroid scintigraphy was used as the gold standard to confirm or exclude hyperthyroidism. Median serum TSH concentration in the hyperthyroid cats (hyperthyroid cats had measurable TSH concentrations (≥0.03 ng/mL), whereas 114 (69.9%) of the 163 euthyroid cats had detectable concentrations. Combining serum TSH with T4 or fT4 concentrations lowered the test sensitivity of TSH from 98.0 to 97.0%, but markedly increased overall test specificity (from 69.9 to 98.8%). Serum TSH concentrations are suppressed in 98% of hyperthyroid cats, but concentrations are measurable in a few cats with mild-to-moderate hyperthyroidism. Measurement of serum TSH represents a highly sensitive but poorly specific test for diagnosis of hyperthyroidism and is best measured in combination with T4 and fT4. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  9. TOPGEAR: a randomised phase III trial of perioperative ECF chemotherapy versus preoperative chemoradiation plus perioperative ECF chemotherapy for resectable gastric cancer (an international, intergroup trial of the AGITG/TROG/EORTC/NCIC CTG)

    International Nuclear Information System (INIS)

    Leong, Trevor; Smithers, B Mark; Michael, Michael; Gebski, Val; Boussioutas, Alex; Miller, Danielle; Simes, John; Zalcberg, John; Haustermans, Karin; Lordick, Florian; Schuhmacher, Christoph; Swallow, Carol; Darling, Gail; Wong, Rebecca

    2015-01-01

    The optimal management of patients with resectable gastric cancer continues to evolve in Western countries. Following publication of the US Intergroup 0116 and UK Medical Research Council MAGIC trials, there are now two standards of care for adjuvant therapy in resectable gastric cancer, at least in the Western world: postoperative chemoradiotherapy and perioperative epirubicin/cisplatin/fluorouracil (ECF) chemotherapy. We hypothesize that adding chemoradiation to standard perioperative ECF chemotherapy will achieve further survival gains. We also believe there are advantages to administering chemoradiation in the preoperative rather than postoperative setting. In this article, we describe the TOPGEAR trial, which is a randomised phase III trial comparing control arm therapy of perioperative ECF chemotherapy with experimental arm therapy of preoperative chemoradiation plus perioperative ECF chemotherapy. Eligible patients with resectable adenocarcinoma of the stomach or gastroesophageal junction will be randomized to receive either perioperative chemotherapy alone (3 preoperative and 3 postoperative cycles of ECF) or perioperative chemotherapy plus preoperative chemoradiation. In the chemoradiation arm, patients receive 2 cycles of ECF plus chemoradiation prior to surgery, and then following surgery 3 further cycles of ECF are given. The trial is being conducted in two Parts; Part 1 (phase II component) has recruited 120 patients with the aim of assessing feasibility, safety and preliminary efficacy of preoperative chemoradiation. Part 2 (phase III component) will recruit a further 632 patients to provide a total sample size of 752 patients. The primary endpoint of the phase III trial is overall survival. The trial includes quality of life and biological substudies, as well as a health economic evaluation. In addition, the trial incorporates a rigorous quality assurance program that includes real time central review of radiotherapy plans and central review of

  10. ECFS: A decentralized, distributed and fault-tolerant FUSE filesystem for the LHCb online farm

    International Nuclear Information System (INIS)

    Rybczynski, Tomasz; Bonaccorsi, Enrico; Neufeld, Niko

    2014-01-01

    The LHCb experiment records millions of proton collisions every second, but only a fraction of them are useful for LHCb physics. In order to filter out the 'bad events' a large farm of x86-servers (∼2000 nodes) has been put in place. These servers boot from and run from NFS, however they use their local disk to temporarily store data, which cannot be processed in real-time ('data-deferring'). These events are subsequently processed, when there are no live-data coming in. The effective CPU power is thus greatly increased. This gain in CPU power depends critically on the availability of the local disks. For cost and power-reasons, mirroring (RAID-1) is not used, leading to a lot of operational headache with failing disks and disk-errors or server failures induced by faulty disks. To mitigate these problems and increase the reliability of the LHCb farm, while at same time keeping cost and power-consumption low, an extensive research and study of existing highly available and distributed file systems has been done. While many distributed file systems are providing reliability by 'file replication', none of the evaluated ones supports erasure algorithms. A decentralised, distributed and fault-tolerant 'write once read many' file system has been designed and implemented as a proof of concept providing fault tolerance without using expensive – in terms of disk space – file replication techniques and providing a unique namespace as a main goals. This paper describes the design and the implementation of the Erasure Codes File System (ECFS) and presents the specialised FUSE interface for Linux. Depending on the encoding algorithm ECFS will use a certain number of target directories as a backend to store the segments that compose the encoded data. When target directories are mounted via nfs/autofs – ECFS will act as a file-system over network/block-level raid over multiple servers.

  11. Study on epoxy/BaTiO3 composite embedded capacitor films (ECFs) for organic substrate applications

    International Nuclear Information System (INIS)

    Cho, Sung-Dong; Lee, Joo-Yeon; Hyun, Jin-Gul; Paik, Kyung-Wook

    2004-01-01

    Embedded capacitor films (ECFs) were newly designed for high dielectric constant and low capacitance tolerance (less than ±5%) embedded capacitor fabrication for organic substrates. ECFs are transferable and B-stage films which can be coated on a releasing film. In terms of materials formulation, ECFs are composed of high dielectric constant BaTiO 3 (BT) powder, specially formulated epoxy resin, and latent curing agent. And in terms of coating process, a roll coating method is used for obtaining film thickness uniformity in a large area. Differential scanning calorimeter (DSC) thermal analysis was conducted to determine the optimum amount of curing agent, curing temperature, and curing time. Changes in the dielectric constant of epoxy/BaTiO 3 composite ECFs with BT particle sizes and contents were investigated. Dielectric constant of 90 was obtained using two different size BaTiO 3 powders mixture. Typically, capacitors of 12 μm thick film with 8 nF/cm 2 with less than ±5% capacitance tolerance and low leakage current (less than 10 -7 A/cm 2 at 10 V) were successfully demonstrated on PCBs using epoxy/BaTiO 3 composite embedded capacitor films

  12. Bacillus subtilis extracytoplasmic function (ECF) sigma factors and defense of the cell envelope.

    Science.gov (United States)

    Helmann, John D

    2016-04-01

    Bacillus subtilis provides a model for investigation of the bacterial cell envelope, the first line of defense against environmental threats. Extracytoplasmic function (ECF) sigma factors activate genes that confer resistance to agents that threaten the integrity of the envelope. Although their individual regulons overlap, σ(W) is most closely associated with membrane-active agents, σ(X) with cationic antimicrobial peptide resistance, and σ(V) with resistance to lysozyme. Here, I highlight the role of the σ(M) regulon, which is strongly induced by conditions that impair peptidoglycan synthesis and includes the core pathways of envelope synthesis and cell division, as well as stress-inducible alternative enzymes. Studies of these cell envelope stress responses provide insights into how bacteria acclimate to the presence of antibiotics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. REPLACEMENT OF SOFTWOOD KRAFT PULP WITH ECF-BLEACHED BAMBOO KRAFT PULP IN FINE PAPER

    Directory of Open Access Journals (Sweden)

    Guanglei Zhao

    2010-06-01

    Full Text Available Non-wood fibers such as bamboo and wheat straw have been playing important roles in the pulp and paper industry in China. In this study an ECF-bleached bamboo kraft pulp was compared with a bleached softwood kraft pulp (NBSK as the reinforcement pulp in fine paper production. Areas that were examined include the refining of pure fibers, influence of bamboo on dewatering, retention, and sizing. The influence of bamboo kraft pulp as a part of a furnish replacing NBSK was compared as well. Results show that fiber shortening was more prominent with bamboo when refined. This resulted in a higher amount of fines, and addition wet-end chemicals may be required to compensate. Handsheets with bamboo as a reinforcement fiber showed similar mechanical and optical properties to handsheets containing NBSK.

  14. Electrocoagulation (EC and Electrocoagulation/Flotation(ECF Processes for Removing High Turbidity from Surface Water Using Al and Fe Electrodes

    Directory of Open Access Journals (Sweden)

    Ghorban Asgari

    2013-08-01

    Full Text Available Electrocoagulation (EC and Electrocoagulation/flotation (ECF processes are simple and efficient in water and wastewater treatment. In recent years, many investigations have focused on the use of these processes for treating of polluted water. The purpose of this study was to investigate the efficiency of EC and ECF processes in removal of high turbidity water using different electrodes in different circumstances. In present study an electrocoagulation and electrocoagulation/ flotation reactor in a lab scale to an approximate volume of 6 liters which is equipped with four Al-AL and Fe-Fe electrodes (200 * 20 * 2 mm was used  for removing of high turbidity water. The effects of operating parameters such as type of electrodes, initial water turbidity, applied voltage (10 to 30 v, initial pH of the solution (3 to 12 and reaction times (5 to 30 minutes were evaluated. The batch experimental results showed that initial turbidity water, initial pH of the solution, different applied voltages up to %88 turbidity as initial turbidity of 1200 NTU have been removed when using Al-Al and Fe-Fe electrodes and reaction times highly effective on the turbidity removal efficiency in these processes. In ECF process, 84% in optimum condition. However, in EC  process the maximum removal was found  up to 68% of initial turbidity when using Al-Al and Fe-Fe electrodes in same operation. Based on the result obtained in this study, the type of electrodes in EC and ECF processes  significantly affect the removal rate of high turbid water. Also, it was found that much higher turbidity removal could be achieved by ECF process than that by EC process in the same condition.

  15. Relationship between first trimester aneuploidy screening test serum analytes and placenta accreta.

    Science.gov (United States)

    Büke, Barış; Akkaya, Hatice; Demir, Sibel; Sağol, Sermet; Şimşek, Deniz; Başol, Güneş; Barutçuoğlu, Burcu

    2018-01-01

    The aim of this study is to determine whether there is a relationship between first trimester serum pregnancy-associated plasma protein A (PAPP-A) and free beta human chorionic gonadotropin (fβhCG) MoM values and placenta accreta in women who had placenta previa. A total of 88 patients with placenta previa who had first trimester aneuploidy screening test results were enrolled in the study. Nineteen of these patients were also diagnosed with placenta accreta. As probable markers of excessive placental invasion, serum PAPP-A and fβhCG MoM values were compared in two groups with and without placenta accreta. Patients with placenta accreta had higher statistically significant serum PAPP-A (1.20 versus 0.865, respectively, p = 0.045) and fβhCG MoM (1.42 versus 0.93, respectively, p = 0.042) values than patients without accreta. Higher first trimester serum PAPP-A and fβhCG MoM values seem to be associated with placenta accreta in women with placenta previa. Further studies are needed to use these promising additional tools for early detection of placenta accreta.

  16. Serum neutralization as a differential serological test for classical swine fever virus and other pestivirus infections

    Directory of Open Access Journals (Sweden)

    Paredes J.C.M.

    1999-01-01

    Full Text Available Serum neutralization tests (SN were performed against classical swine fever virus (CSFV, bovine viral diarrhea virus (BVDV and border disease virus (BDV on samples of swine serum collected for screening of antibodies to CSFV, in order to determine the SN value as a differential serological test. Ninety-nine sera out of a sample of 16,664 were positive for antibodies to pestiviruses in an ELISA test which did not distinguish antibodies to different pestiviruses. When submitted to SN, 81 sera were positive for CSFV antibodies only. In 17 sera, crossreactive antibodies to either CSFV, BVDV or BDV were detected. In most of these sera (13 out of 17 the differences between SN titres against the three viruses were not sufficient to estimate which was the most likely antibody-inducing virus. It was concluded that, for the SN to be useful in such differentiation, it is essential to examine a sample which must include a representative number of sera from the same farm where suspect animals were detected. When isolated serum samples are examined, such as those obtained with the sampling strategy adopted here, the SN may give rise to inconclusive results.

  17. Prospective Evaluation of Serum β-Glucan Testing in Patients With Probable or Proven Fungal Diseases

    Science.gov (United States)

    Angebault, Cécile; Lanternier, Fanny; Dalle, Frédéric; Schrimpf, Cécile; Roupie, Anne-Laure; Dupuis, Aurélie; Agathine, Aurélie; Scemla, Anne; Paubelle, Etienne; Caillot, Denis; Neven, Bénédicte; Frange, Pierre; Suarez, Felipe; d'Enfert, Christophe; Lortholary, Olivier; Bougnoux, Marie-Elisabeth

    2016-01-01

    Background. Early diagnosis and treatment are crucial in invasive fungal diseases (IFD). Serum (1-3)-β-d-glucan (BG) is believed to be an early IFD marker, but its diagnostic performance has been ambiguous, with insufficient data regarding sensitivity at the time of IFD diagnosis (TOD) and according to outcome. Whether its clinical utility is equivalent for all types of IFD remains unknown. Methods. We included 143 patients with proven or probable IFD (49 invasive candidiasis, 45 invasive aspergillosis [IA], and 49 rare IFD) and analyzed serum BG (Fungitell) at TOD and during treatment. Results. (1-3)-β-d-glucan was undetectable at TOD in 36% and 48% of patients with candidemia and IA, respectively; there was no correlation between negative BG results at TOD and patients' characteristics, localization of infection, or prior antifungal use. Nevertheless, patients with candidemia due to Candida albicans were more likely to test positive for BG at TOD (odds ratio = 25.4, P = .01) than patients infected with other Candida species. In 70% of the patients with a follow-up, BG negativation occurred in >1 month for candidemia and >3 months for IA. A slower BG decrease in patients with candidemia was associated with deep-seated localizations (P = .04). Thirty-nine percent of patients with rare IFD had undetectable BG at TOD; nonetheless, all patients with chronic subcutaneous IFD tested positive at TOD. Conclusions. Undetectable serum BG does not rule out an early IFD, when the clinical suspicion is high. After IFD diagnostic, kinetics of serum BG are difficult to relate to clinical outcome. PMID:27419189

  18. Experimental and numerical analyses of pure copper during ECFE process as a novel severe plastic deformation method

    Directory of Open Access Journals (Sweden)

    M. Ebrahimi

    2014-02-01

    Full Text Available In this paper, a new severe plastic deformation method called equal channel forward extrusion (ECFE process has been proposed and investigated by experimental and numerical approaches on the commercial pure copper billets. The experimental results indicated that the magnitudes of yield strength, ultimate tensile strength and Vickers micro-hardness have been markedly improved from 114 MPa, 204 MPa and 68 HV as the annealed condition to 269 MPa, 285 MPa and 126 HV after the fourth pass of ECFE process, respectively. In addition, scanning electron microscopy observation of the samples showed that the average grain size of the as-received state which is about 22 μm has been reduced to 1.4 μm after the final pass. The numerical investigation suggested that although one pass ECFE process fabricates material with the mean effective strain magnitude of about 1, the level of imposed effective plastic strain gradually diminishes from the circumference to the center of the deformed billet.

  19. Significance of the combined tests application in serum and liquor of patients with suspected neurosyphilis

    Directory of Open Access Journals (Sweden)

    Mirković Mihailo

    2007-01-01

    Full Text Available Background. Tertiary syphilis develops in 8-40% of untreated patients. It is most commonly manifested in the form of neurosyphilis, which can be asymptomatic taking the form of tabes dorsalis or progressive paralyze. Nowadays, in the developed countries, progressive paralyze is a rather rare disease, although the incidence of this disease has been rising within the last decades. Case report. We reported a 74-year-old male with the clinical image of dementia showing psychotic symptoms. On cytobiochemical examination of cerebrospinal liquor, hyperproteinorhacmia of 0.70 g/l with the normal number of cells was revealed. Computed tomography of the brain showed the marked cortical cerebral and cerebellar reduction changes with multiple ischemic lesions. Within a routine examination of patients with demention, we performed serologic reactions to syphilis out of which the Veneral Disease Researc Laboratory (VDRL test in serum and liquor was unreactive, while the Treponema pallidum hemagglutination (TPNA test in serum and liquor was positive. Positivity in serum and liquor was additionally confirmed by the Western blot method and fluoroscent treponema antibody (FTA test. The treatment with benzathine fenylpenicilline 2.4 g once weekly resulted in significant improving the psychotic symptoms of the disease even after two weeks. Conclusion. This case report showed that within the differential diagnostics in patients with demention or psychotic disorder it is obligatory to consider syphilis of the nervous system, as well as to apply a combination of various tests which, besides the typical liquor findings, significantly improve the accuracy of diagnosis. Such approach is especially important regarding the fact that neurosyphilis can remain clinically quite asymptomatic for a long period, which could lead to late therapy, while, on the contrary, an adequate and timely treatment can contribute to a significant recovery of any patients.

  20. Improvement of western blot test specificity for detecting equine serum antibodies to Sarcocystis neurona.

    Science.gov (United States)

    Rossano, M G; Mansfield, L S; Kaneene, J B; Murphy, A J; Brown, C M; Schott, H C; Fox, J C

    2000-01-01

    Equine protozoal myeloencephalitis (EPM) is a neurological disease of horses and ponies caused by the apicomplexan protozoan parasite Sarcocystis neurona. The purposes of this study were to develop the most stringent criteria possible for a positive test result, to estimate the sensitivity and specificity of the EPM Western blot antibody test, and to assess the ability of bovine antibodies to Sarcocystis cruzi to act as a blocking agent to minimize false-positive results in the western blot test for S. neurona. Sarcocystis neurona merozoites harvested from equine dermal cell culture were heat denatured, and the proteins were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in a 12-20% linear gradient gel. Separated proteins were electrophoretically transferred to polyvinylidene fluoride membranes and blocked in 1% bovine serum albumin and 0.5% Tween-Tris-buffered saline. Serum samples from 6 horses with S. neurona infections (confirmed by culture from neural tissue) and 57 horses without infections (horses from the Eastern Hemisphere, where S. neurona does not exist) were tested by Western blot. Horses from both groups had reactivity to the 62-, 30-, 16-, 13-, 11-, 10.5-, and 10-kD bands. Testing was repeated with another step. Blots were treated with bovine S. cruzi antibodies prior to loading the equine samples. After this modification of the Western blot test, positive infection status was significantly associated with reactivity to the 30- and 16-kD bands (Pblot had a sample sensitivity of 100% and sample specificity of 98%. It is concluded that the specificity of the Western blot test is improved by blocking proteins not specific to S. neurona and using reactivity to the 30- and 16-kD bands as the criterion for a positive test.

  1. Sensitivity Comparison of the Skin Prick Test and Serum and Fecal Radio Allergosorbent Test (RAST in Diagnosis of Food Allergy in Children

    Directory of Open Access Journals (Sweden)

    Hamid Reza Kianifar

    2016-05-01

    Full Text Available Background: Diagnosis of food allergy is difficult in children. Food allergies are diagnosed using several methods that include medical histories, clinical examinations, skin prick and serum-specific immunoglobulin E (IgE tests, radio-allergosorbent test (RAST, food challenge, and supervised elimination diets. In this study we evaluated allergies to cow's milk, egg, peanut, and fish in children with suspected food allergies with skin prick tests and serum and feces RAST. Methods: Forty-one children with clinical symptoms of food allergies were enrolled in the study. Skin prick tests and serum and fecal RAST were performed and compared with challenge tests. Results: The most common sites of food allergy symptoms were gastrointestinal (82.9% and skin (48.8%. 100% of the patients responded to the challenge tests with cow’s milk, egg, peanut, and fish. 65% of the patients tested positive with the skin prick test, 12.1% tested positive with serum RAST, and 29.2% tested positive with fecal RAST. Conclusions: The skin prick test was more sensitive than serum or fecal RAST, and fecal RAST was more than twice as sensitive as serum RAST.

  2. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  3. Accuracy of cotinine serum test to detect the smoking habit and its association with periodontal disease in a multicenter study.

    Science.gov (United States)

    Duque, A; Martínez, P-J; Giraldo, A; Gualtero, D-F; Ardila, C-M; Contreras, A; Duarte, S; Lafaurie, G-I

    2017-07-01

    The validity of the surveys on self-reported smoking status is often questioned because smokers underestimate cigarette use and deny the habit. It has been suggested that self-report should be accompanied by cotinine test. This report evaluates the usefulness of serum cotinine test to assess the association between smoking and periodontal status in a study with a large sample population to be used in studies with other serum markers in epidemiologic and periodontal medicine researches. 578 patients who were part of a multicenter study on blood biomarkers were evaluated about smoking and its relation to periodontal disease. Severity of periodontal disease was determinate using clinical attachment loss (CAL). Smoking was assessed by a questionnaire and a blood sample drawn for serum cotinine determination. The optimal cut-off point for serum cotinine was 10 ng/ml. Serum cotinine showed greater association with severity of CAL than self-report for mild-moderate CAL [OR 2.03 (CI95% 1.16-3.53) vs. OR 1.08 (CI95% 0.62-1.87) ] advanced periodontitis [OR 2.36 (CI95% 1.30- 4.31) vs. OR 2.06 (CI95% 0.97-4.38) ] and extension of CAL > 3 mm [ OR 1.78 (CI95% 1.16-1.71) vs. 1.37 (CI95% 0.89-2.11)]. When the two tests were evaluated together were not shown to be better than serum cotinine test. Self-reported smoking and serum cotinine test ≥ 10ng/ml are accurate ,complementary and more reliable methods to assess the patient's smoking status and could be used in studies evaluating serum samples in large population and multicenter studies. The serum cotinine level is more reliable to make associations with the patient's periodontal status than self-report questionnaire and could be used in multicenter and periodontal medicine studies.

  4. Serum auto-antibody testing for early diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Parvez, S.

    2012-01-01

    The aim of this thesis is generate prototype-tests suitable for randomized prospective validation of auto-antibody based diagnostic testing using serum samples. Tumours can stimulate the production of auto-antibodies against autologous cellular proteins known as TAAs (tumour associated antigens). This discovery has lead to a possibility of using the auto-antibodies as serological tools for the early diagnosis and management of breast cancer. The recombinant proteins expressed by the SEREX clones, identified from screenings of brain and lung tumour, were used for the production of the protein microarrays and macroarrays. The protein microarrays showed better correlation between the replicates of the serum samples used. The optimized protocols were used for the subsequent experiments. A sizable panel of 642 clone-proteins was selected by marker-screening on protein macroarrays with 38000 clones. These 642 clone-proteins were used to generate protein microarrays that differentiated serum samples from breast cancer patients and controls. Antigenic peptide motifs were identified by in-silico analysis of 642 clone-proteins and peptide arrays were generated using synthetically generated peptides. Comparative studies between protein microarrays and peptide microarrays were done using breast cancer and healthy control samples. Simultaneously, SEREX strategy was used for the identification of the immunogenic TAAs. I identified 192 cDNA expression clones derived from breast cancer tissue samples and the selection was done using breast cancer sera. The genes corresponding to these clones were found over-represented for the pathways that are known to be associated with cancers. These genes showed typical features of TAAs, like over-expression, mutations and fusion genes. (author)

  5. Clinical evaluation of serum bile acids as a new liver function test

    Energy Technology Data Exchange (ETDEWEB)

    Biffl, H; Pristautz, H; Parsche, P; Passath, A; Leb, G [Graz Univ. (Austria). Medizinische Klinik

    1980-01-01

    In a randomized patient material, with various histologically verified hepatobiliary diseases, the serum levels of Cholyl glycine (CG) and Sulfolithocholyl glycine (SLCG) were compared with each other. SLCG levels are a more sensitive parameter and permit a more significant differentiation between fatty and normal livers and between cases with and without portal hypertension in liver cirrhosis. There were poor correlations between the hitherto routinely performed laboratory tests and the SLCG levels, but good correlations between SLCG and defined parenchymal liver diseases. The publication ends with the presentation of a newly developed SLCG-stimulation test, which provides a staging of parenchymal liver diseases without unnecessary requirements of time and material and with minimal stress to the patients.

  6. ATP-dependent Conformational Changes Trigger Substrate Capture and Release by an ECF-type Biotin Transporter.

    Science.gov (United States)

    Finkenwirth, Friedrich; Sippach, Michael; Landmesser, Heidi; Kirsch, Franziska; Ogienko, Anastasia; Grunzel, Miriam; Kiesler, Cornelia; Steinhoff, Heinz-Jürgen; Schneider, Erwin; Eitinger, Thomas

    2015-07-03

    Energy-coupling factor (ECF) transporters for vitamins and metal ions in prokaryotes consist of two ATP-binding cassette-type ATPases, a substrate-specific transmembrane protein (S component) and a transmembrane protein (T component) that physically interacts with the ATPases and the S component. The mechanism of ECF transporters was analyzed upon reconstitution of a bacterial biotin transporter into phospholipid bilayer nanodiscs. ATPase activity was not stimulated by biotin and was only moderately reduced by vanadate. A non-hydrolyzable ATP analog was a competitive inhibitor. As evidenced by cross-linking of monocysteine variants and by site-specific spin labeling of the Q-helix followed by EPR-based interspin distance analyses, closure and reopening of the ATPase dimer (BioM2) was a consequence of ATP binding and hydrolysis, respectively. A previously suggested role of a stretch of small hydrophobic amino acid residues within the first transmembrane segment of the S units for S unit/T unit interactions was structurally and functionally confirmed for the biotin transporter. Cross-linking of this segment in BioY (S) using homobifunctional thiol-reactive reagents to a coupling helix of BioN (T) indicated a reorientation rather than a disruption of the BioY/BioN interface during catalysis. Fluorescence emission of BioY labeled with an environmentally sensitive fluorophore was compatible with an ATP-induced reorientation and consistent with a hypothesized toppling mechanism. As demonstrated by [(3)H]biotin capture assays, ATP binding stimulated substrate capture by the transporter, and subsequent ATP hydrolysis led to substrate release. Our study represents the first experimental insight into the individual steps during the catalytic cycle of an ECF transporter in a lipid environment. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  7. USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2010-06-01

    Full Text Available Regarding a new regulation from Indonesia FDA (Badan POM-RI, all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm, with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990. Precision of the method was very good with coefficient of variance (CV 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.   Keywords: Rifampicin, Validation, USFDA-Guideline

  8. Lipophilic extractives from several nonwoody lignocellulosic crops (flax, hemp, sisal, abaca) and their fate during alkaline pulping and TCF/ECF bleaching.

    Science.gov (United States)

    Marques, Gisela; del Río, José C; Gutiérrez, Ana

    2010-01-01

    The fate of lipophilic extractives from several nonwoody species (flax, hemp, sisal and abaca) used for the manufacturing of cellulose pulps, was studied during soda/anthraquinone (AQ) pulping and totally chorine free (TCF) and elemental chlorine free (ECF) bleaching. With this purpose, the lipophilic extracts from the raw materials and their unbleached and bleached industrial pulps, were analyzed by gas chromatography-mass spectrometry. Aldehydes, hydroxyfatty acids and esterified compounds such as ester waxes, sterol esters and alkylferulates strongly decreased after soda/AQ pulping while alkanes, alcohols, free sterols and sterol glycosides survived the cooking process. Among the lipophilic extractives that remained in the unbleached pulps, some amounts of free sterols were still present in the TCF pulps whereas they were practically absent in the ECF pulps. Sterol glycosides were also removed after both TCF and ECF bleaching. By contrast, saturated fatty acids, fatty alcohols and alkanes were still present in both bleached pulps.

  9. Replacement of serum with ocular fluid for cryopreservation of immature testes.

    Science.gov (United States)

    Pothana, Lavanya; Devi, Lalitha; Venna, Naresh Kumar; Pentakota, Niharika; Varma, Vivek Phani; Jose, Jedy; Goel, Sandeep

    2016-12-01

    Cryopreservation of immature testis is a feasible approach for germplasm preservation of male animals. Combinations of dimethyl sulfoxide (DMSO) and foetal bovine serum (FBS) are used for testis cryopreservation. However, an alternative to FBS is needed, because FBS is expensive. Buffalo ocular fluid (BuOF), a slaughter house by-product, could be an economical option. The objective of the present study was to assess whether BuOF can replace FBS for cryopreservation of immature mouse (Mus musculus), rat (Rattus norvegicus), and buffalo (Bubalus bubalis) testes. Results showed that rodent and buffalo testes frozen in DMSO (10% for rodents and 20% for buffalo) with 20% FBS or BuOF had similar numbers of viable and DNA-damaged cells (P > 0.05). The expression of cell proliferation- (PCNA) and apoptosis-specific proteins (Annexin V and BAX/BCL2 ratio) were also comparable in mouse and buffalo testes frozen in DMSO with FBS or BuOF (P > 0.05). Interestingly, rat testis frozen in DMSO with BuOF had lower expression of Annexin V protein than testis frozen in DMSO with FBS (P  0.05). These findings provide evidence that BuOF has potential to replace FBS for cryopreservation of immature rodent and buffalo testis. Further investigation is needed to explore whether BuOF can replace FBS for testis cryopreservation of other species. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Effect of centrifuge test on blood serum lipids index of cadet pilots.

    Science.gov (United States)

    Wochyński, Zbigniew; Kowalczuk, Krzysztof; Kłossowski, Marek; Sobiech, Krzysztof A

    2016-01-01

    This study aimed at investigating the relationship between the lipid index (WS) in the examined cadets and duration of exposure to +Gz in the human centrifuge. The study involved 19 first-year cadets of the Polish Air Force Academy in Dęblin. Tests in the human centrifuge were repeated twice, i.e. prior to (test I) and 45 days after (test II). After exposure to +Gz, the examined cadets were divided into 2 groups. Group I (N=11) included cadets subjected to a shorter total duration of exposure to +Gz, while group II (N=8) included cadets with a longer total duration of exposure to +Gz. Total cholesterol (TC), high density lipoprotein (HDL), triglycerides (TG), and apolipoproteins A1 and B were assayed in blood serum prior to (assay A) and after (assay B) both exposures to +Gz. Low density lipoprotein (LDL) level was estimated from the Friedewald formula. WS is an own mathematical algorithm. WS was higher in group II, assay A - 10.0 and B - 10.08 of test I in the human centrifuge than in group I where the WS values were 6.91 and 6.96, respectively. WS was also higher in group II in assay A - 10.0 and B -10.1 of test II in the human centrifuge than in group I - 6.96 and 6.80, respectively. The higher value of WS in group II, both after the first and second exposure to +Gz in human centrifuge, in comparison with group I, indicated its usefulness for determination of the maximum capability of applying acceleration of the interval type during training in the human centrifuge.

  11. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.

    Science.gov (United States)

    Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard

    2011-10-10

    Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled

  12. Photocleavage-based affinity purification of biomarkers from serum: Application to multiplex allergy testing.

    Directory of Open Access Journals (Sweden)

    Zhi Wan

    Full Text Available Multiplex serological immunoassays, such as implemented on microarray or microsphere-based platforms, provide greater information content and higher throughput, while lowering the cost and blood volume required. These features are particularly attractive in pediatric food allergy testing to facilitate high throughput multi-allergen analysis from finger- or heel-stick collected blood. However, the miniaturization and microfluidics necessary for creating multiplex assays make them highly susceptible to the "matrix effect" caused by interference from non-target agents in serum and other biofluids. Such interference can result in lower sensitivity, specificity, reproducibility and quantitative accuracy. These problems have in large part prevented wide-spread implementation of multiplex immunoassays in clinical laboratories. We report the development of a novel method to eliminate the matrix effect by utilizing photocleavable capture antibodies to purify and concentrate blood-based biomarkers (a process termed PC-PURE prior to detection in a multiplex immunoassay. To evaluate this approach, it was applied to blood-based allergy testing. Patient total IgE was purified and enriched using PC-PURE followed by multiplex microsphere-based detection of allergen-specific IgEs (termed the AllerBead assay. AllerBead was formatted to detect the eight most common pediatric food allergens: milk, soy, wheat, egg, peanuts, tree nuts, fin fish and shellfish, which account for >90% of all pediatric food allergies. 205 serum samples obtained from Boston Children's Hospital were evaluated. When PC-PURE was employed with AllerBead, excellent agreement was obtained with the standard, non-multiplex, ImmunoCAP® assay (average sensitivity above published negative predictive cutoffs = 96% and average Pearson r = 0.90; average specificity = 97%. In contrast, poor ImmunoCAP®-correlation was observed when PC-PURE was not utilized (average sensitivity above published negative

  13. Can serums be replaced by Mueller‑Hinton agar in germ tube test?

    African Journals Online (AJOL)

    2016-03-03

    Mar 3, 2016 ... various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and Mueller‑Hinton agar (MHA). Materials and Methods: Fifty species isolated from various clinical samples that were defined as C. albicans by both conventional and DNA sequence analysis methods were included in the ...

  14. Seroprevalence of Mycoplasma gallisepticum antibody by ELISA and serum plate agglutination test of laying chicken

    Directory of Open Access Journals (Sweden)

    Md. Zulfekar Ali

    2015-01-01

    Full Text Available Aim: Mycoplasma gallisepticum (MG is important avian pathogen responsible for chronic respiratory disease of chicken and turkeys, which result in large economic loss for the poultry industry. The objectives of this study were determination of seroprevalence of MG antibody of commercial layer chicken at laying period in selected areas of Bangladesh. Materials and Methods: A total of 563 blood samples were collected randomly from selected commercial layer chickens at laying period during the period from July to December, 2013. Indirect enzyme linked immunosorbent assay (iELISA and serum plate agglutination (SPA test were performed to detect the presence of antibodies against MG. Results: Of 563 samples, 64.47% and 56.13% showed an overall prevalence of MG antibodies in iELISA and SPA test respectively. Prevalence of MG was recorded the highest (69.63% at 50-55 weeks of age compared with lowest (53.26% at 56-61 weeks of age (p<0.05. Significant (p<0.05 effect of breed were observed in the seroprevalence of MG infection in layer birds in the present study. The overall, 68.77%, 63.74% and 59.37% prevalence were found respectively in sonali, ISA Brown and White leg horn. The prevalence of MG antibodies was the highest (70.13% in December followed by November (68%, October (65.67%, August (63.46%, September (58.54% and July (51.78% month. The seroprevalence of MG antibodies was higher (69.63% in most of the large flocks and lower (56.82% in small flocks. Conclusion: Therefore, might be suggested that the commercial layer farms should be routinely checked to monitor MG infection and the reactor birds should be culled since MG organism has the potential to transmit vertically. The correlation between MG antibody in month and flock size was not significant (p=0.359 and p=0.868, respectively.

  15. Alkaline peroxide treatment of ECF bleached softwood kraft pulps: part 2. effect of increased fiber charge on refining, wet-end application, and hornification

    Science.gov (United States)

    Zheng Dang; Thomas Elder; Jeffery S. Hsieh; Arthur J. Ragauskas

    2007-01-01

    The effect of increased fiber charge on refining, cationic starch adsorption, and hornification was examined. Two pulps were investigated: (1) a softwood (SW) kraft pulp (KP) which was bleached elementally chlorine-free (ECF) and sewed as control; and (2) a control pulp treated with alkaline peroxide, which had a higher fiber charge. It was shown that increased fiber...

  16. Utility of testing for monoclonal bands in serum of patients with suspected osteoporosis

    DEFF Research Database (Denmark)

    Abrahamsen, B.; Andersen, Ivan; Christensen, Susanne S.

    2005-01-01

    OBJECTIVE: To determine whether measuring monoclonal bands (M component) in serum should be part of the investigation of patients referred to osteoporosis clinics. DESIGN: Retrospective, cross sectional, observational study. SETTING: Referral centre for osteoporosis in a university hospital...

  17. Cross-sectional study of serum antibodies against Sarcocystis neurona in cats tested for antibodies against Toxoplasma gondii.

    Science.gov (United States)

    Rossano, Mary G; Murphy, Alice J; Vrable, Ruth A; Vanzo, Nicole E; Lewis, Stacy K; Sheline, Katherine D; Kaneene, John B; Mansfield, Linda S

    2002-08-15

    To determine apparent seroprevalence of antibodies against Sarcocystis neurona in a population of domestic cats previously tested for antibodies against Toxoplasma gondii. Cross-sectional study. Serum from 196 domestic cats. Banked serum samples submitted to the Michigan State University Animal Health Diagnostic Laboratory for T. gondii diagnostic testing were tested for antibodies against S. neurona by use of an indirect fluorescent antibody (IFA) test and a western blot test. Submission records were analyzed to determine descriptive statistics and test for associations between positive results of a test for S. neurona and other variables in the data set. 10 of 196 (5%) samples yielded positive results for antibodies against S. neurona by use of western blot analysis, whereas 27 samples yielded positive results by use of the IFA. No association was found between S. neurona western blot test results and T. gondii test results, age, sex, or the reason for T. gondii testing. The S. neurona IFA titer was positively and significantly associated with positive results of western blot analysis. Domestic cats are not likely to play a substantial role as intermediate hosts in the natural life cycle of S. neurona. Results indicate that natural infection of domestic cats may occur, and small animal practitioners should be aware of this fact when evaluating cats with neurologic disease. The S. neurona IFA test had lower specificity than western blot analysis.

  18. Effect of haemolysis and repeated freeze-thawing cycles on wild boar serum antibody testing by ELISA

    Directory of Open Access Journals (Sweden)

    Boadella Mariana

    2011-11-01

    Full Text Available Abstract Background Monitoring wildlife diseases is needed to identify changes in disease occurrence. Wildlife blood samples are valuable for this purpose but are often gathered haemolysed. To maximise information, sera often go through repeated analysis and freeze-thaw cycles. Herein, we used samples of clean and haemolysed Eurasian wild boar (Sus scrofa serum stored at -20°C and thawed up to five times to study the effects of both treatments on the outcome of a commercial ELISA test for the detection of antibodies against Suid Herpesvirus 1 (ADV. Results The estimated prevalence of antibodies against ADV was 50-53% for clean and haemolysed sera. Hence, haemolysis did not reduce the mean observed serum antibody prevalence. However, 10 samples changed their classification after repeated freeze-thawing. This included 3 (15% of the clean sera and 7 (41% of the haemolysed sera. Conclusions We recommend (1 establishing more restrictive cut-off values when testing wildlife sera, (2 recording serum quality prior to sample banking, (3 recording the number of freezing-thawing cycles and (4 store sera in various aliquots to reduce repeated usage. For instance, sera with more than 3 freeze-thaw cycles and a haemolysis of over 3 on a scale of 4 should better be discarded for serum antibody monitoring. Even clean (almost not haemolysed sera should not go through more than 5 freeze-thaw cycles.

  19. Comparison of Brucella immunoglobulin M and G flow assays with serum agglutination and 2-mercaptoethanol tests in the diagnosis of brucellosis

    NARCIS (Netherlands)

    Zeytinoğlu, Ayşin; Turhan, Ajda; Altuğlu, Imre; Bilgiç, Altinay; Abdoel, Theresia H.; Smits, Henk L.

    2006-01-01

    The diagnostic value of Brucella IgM/IgG flow assays was evaluated in comparison with serum agglutination and 2-mercaptoethanol tests by testing a selection of serum samples submitted to the laboratory because of clinical suspicion of brucellosis. All 39 admission and 11 follow-up samples that

  20. Performing IgE serum testing due to bioinformatics matches in the allergenicity assessment of GM crops.

    Science.gov (United States)

    Goodman, Richard E

    2008-10-01

    Proteins introduced into genetically modified (GM) organisms through genetic engineering must be evaluated for their potential to cause allergic disease under various national laws and regulations. The Codex Alimentarius Commission guidance document (2003) calls for testing of serum IgE binding to the introduced protein if the gene was from an allergenic source, or the sequence of the transferred protein has >35% identity in any segment of 80 or more amino acids to a known allergen or shares significant short amino acid identities. The Codex guidance recognized that the assessment will evolve based on new scientific knowledge. Arguably, the current criteria are too conservative as discussed in this paper and they do not provide practical guidance on serum testing. The goals of this paper are: (1) to summarize evidence supporting the level of identity that indicates potential risk of cross-reactivity for those with existing allergies; (2) to provide example bioinformatics results and discuss their interpretation using published examples of proteins expressed in transgenic crops; and (3) to discuss key factors of experimental design and methodology for serum IgE tests to minimize the rate of false negative and false positive identification of potential allergens and cross-reactive proteins.

  1. Defined culture medium for stem cell differentiation: applicability of serum-free conditions in the mouse embryonic stem cell test.

    Science.gov (United States)

    Riebeling, Christian; Schlechter, Katharina; Buesen, Roland; Spielmann, Horst; Luch, Andreas; Seiler, Andrea

    2011-06-01

    The embryonic stem cell test (EST) is a validated method to assess the developmental toxicity potency of chemicals. It was developed to reduce animal use and allow faster testing for hazard assessment. The cells used in this method are maintained and differentiated in media containing foetal calf serum. This animal product is of considerable variation in quality, and individual batches require extensive testing for their applicability in the EST. Moreover, its production involves a large number of foetuses and possible animal suffering. We demonstrate the serum-free medium and feeder cell-free maintenance of the mouse embryonic stem cell line D3 and investigate the use of specific growth factors for induction of cardiac differentiation. Using a combination of bone morphogenetic protein-2, bone morphogenetic protein-4, activin A and ascorbic acid, embryoid bodies efficiently differentiated into contracting myocardium. Additionally, examining levels of intracellular marker proteins by flow cytometry not only confirmed differentiation into cardiomyocytes, but demonstrated significant differentiation into neuronal cells in the same time frame. Thus, this approach might allow for simultaneous detection of developmental effects on both early mesodermal and neuroectodermal differentiation. The serum-free conditions for maintenance and differentiation of D3 cells described here enhance the transferability and standardisation and hence the performance of the EST. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Total protein concentration and diagnostic test results for gray wolf (Canis lupus) serum using Nobuto filter paper strips

    Science.gov (United States)

    Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.

    2015-01-01

    Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.

  3. The EGG 57-CO B-12 absorption test, in the evaluation of patients with low serum B-12

    International Nuclear Information System (INIS)

    Sinow, R.M.; Carmel, R.; Siegel, M.E.

    1985-01-01

    The Schilling Test (ST) is the standard test for diagnosing vitamin B-12 malabsorption (MA). However, patients with subtle gastric dysfunction may have normal ST, but impaired absorption of B-12 given with food. The authors have adapted an Egg B-12 Absorption Test (EBAT) in which 57-Co cyanocobalamin (57-Co B-12) is mixed with scrambled egg to evaluate this phenomenon in patients with low serum B-12, normal ST and possible subtle MA. Lyophilized egg yolk is reconstituted and mixed with 57-Co- B-12 of equal dose to that of ST. The authors studied 46 individuals: 13 controls, 5 patients with known pernicious anemia (PA), in addition to 28 patients with low serum B-12 levels and normal ST. ST/EBAT ratios were calculated. Twenty-eight test patients excreted 13.3% on ST and 3.5% on EBAT. Mean ST/EBAT ratio was 8.2 (1.4-35.9). Five had EBAT results in the PA range (<1%) and ST/EBAT ratios (14.4-35.9) that were significantly elevated. This group is also evaluated with pepsinogen I/II ratios, gastric analysis, deoxyuridine suppression tests, anti intrinsic factor, and antiparietal cell antibodies. The authors' results indicate that the EBAT can differentiate between PA and non PA patients, and that some patients with low serum B-12 levels and normal ST may, in fact, have subtle MA. The EBAT, combined with ST/EBAT ratio, may provide a means for identifying this group of patients

  4. Evaluation of the accuracy of serum MMP-9 as a test for colorectal cancer in a primary care population

    Directory of Open Access Journals (Sweden)

    Colbourne Lynne

    2006-10-01

    Full Text Available Abstract Background Bowel cancer is common and is a major cause of death. Meta-analysis of randomised controlled trials estimates that screening for colorectal cancer using faecal occult blood (FOB test reduces mortality from colorectal cancer by 16%. However, FOB testing has a low positive predictive value, with associated unnecessary cost, risk and anxiety from subsequent investigation, and is unacceptable to a proportion of the target population. Increased levels of an enzyme called matrix metalloproteinase 9 (MMP-9 have been found to be associated with colorectal cancer, and this can be measured from a blood sample. Serum MMP-9 is potentially an accurate, low risk and cost-effective population screening tool. This study aims to evaluate the accuracy of serum MMP-9 as a test for colorectal cancer in a primary care population. Methods/Design People aged 50 to 69 years, who registered in participating general practices in the West Midlands Region, will be asked to complete a questionnaire that asks about symptoms. Respondents who describe any colorectal symptoms (except only abdominal bloating and/or anal symptoms and are prepared to provide a blood sample for MMP9 estimation and undergo a colonoscopy (current gold standard investigation will be recruited at GP based clinics by a research nurse. Those unfit for colonoscopy will be excluded. Colonoscopies will be undertaken in dedicated research clinics. The accuracy of MMP-9 will be assessed by comparing the MMP-9 level with the colonoscopy findings, and the combination of factors (e.g. symptoms and MMP-9 level that best predict a diagnosis of malignancy (invasive disease or polyps will be determined. Discussion Colorectal cancer is a major cause of morbidity and mortality. Most colorectal cancers arise from adenomas and there is a period for early detection by screening, but available tests have risks, are unacceptable to many, have high false positive rates or are expensive. This study will

  5. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Weijun; Leach, Robin; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srinivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-08-03

    Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.

  6. The Comparison Of TSH IRMA Serum Level With TRH Test Value In Healthy People Who Are Suspected To Have Hyperthyroidism

    Directory of Open Access Journals (Sweden)

    Keshavarz zirak A

    2005-06-01

    Full Text Available Background: Sub clinical hyperthyroidism is a state of subnormal serum TSH and T3,T4 within normal range, although usually without overt clinical manifestation but many disastrous complications especially in senile patient. In Iranian people, serum TSH is generally assayed by IRMA method. This study is aimed to determine the value of low serum TSH in these patients, better management and decision when encountered. Materials and Methods: The populations under study are guys with serum TSH lower than 0.5mu/l and normal thyroid hormones without known thyroidal and non-thyroidal illness. A basal serum TSH and TSH 30 minutes after TRH injection intra venous were sampled and correlation of clinical signs and symptoms and basal TSH with sub clinical hyperthyroidism was considered. Results: The population under study was categorized into five groups and prevalence of sub clinical hyperthyroidism was noted. In patients with b.TSH equal or lower than 0.1mu/l, 100%, 0.1-0.2mu/l, 75%, 0.2-0.3mu/l, 38.5%, 0.3-0.4mu/l, 14.3% and TSH levels greater than 0.4mu/l, were all normal. After analyzing of these data and determination of sensitivity and specificity of IRMA, it was concluded that IRMA is not sufficient to distinguish sub clinical hyperthyroidism, although there is a good linear (r=0.68; P<0.001 and cubic (r=0.79; P<0.001 relationship between b.TSH and d.TSH. Conclusion: Since TRH test is not cost effective for all cases, TSH levels lower than 0.25mu/l, can be considered as sub clinical hyperthyroidism and levels more than 0.4mu/l, as normal. In cases with TSH level between 0.25 and 0.4mu/l, TRH test is needed in high-risk patients.

  7. Trends in serum creatinine testing in Oxfordshire, UK, 1993-2013: a population-based cohort study.

    Science.gov (United States)

    Oke, Jason; Shine, Brian; McFadden, Emily; Stevens, Richard; Lasserson, Daniel; Perera, Rafael

    2015-12-16

    To determine how many kidney function tests are done, on whom, how frequently they are performed and how they have changed over time. Retrospective study of all serum creatinine, urine albumin and urine creatinine tests. Primary and secondary care in Oxfordshire from 1993 to 2013. Unselected population of 1,220,447 people. The total number of creatinine and urinary protein tests ordered from primary and secondary care and the number of tests per year stratified by categories of estimated glomerular filtration rate (eGFR). The frequency of testing in patients having their kidney function monitored. Creatinine requests from primary care increased steadily from 1997 and exceeded 220,000 requests in 2013. Tests corresponding to normal kidney function (eGFR >60/mL/min/1.73 m(2)) constituted 59% of all kidney function tests in 1993 and accounted for 83% of all tests in 2013. Test corresponding to chronic kidney disease (CKD) stages 3-5 declined after 2007. Reduced kidney function, albuminuria, male gender, diabetes and age were independently associated with more frequent monitoring. For a female patient between 61 and 80 years and with stage 3a CKD, the average number of serum creatinine tests (95% CI) was 3.23/year (3.19 to 3.26) and for a similar woman with diabetes, the average number of tests was 5.50 (5.44 to 5.56) tests per year. There has been a large increase in the number of kidney function tests over the past two decades. However, we found little evidence that this increase is detecting more CKD. Tests are becoming more frequent in people with and without evidence of renal impairment. Future work using a richer data source could help unravel the underlying reasons for the increased testing and determine how much is necessary and useful. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. ELISA Cut-off Point for the Diagnosis of Human Brucellosis; a Comparison with Serum Agglutination Test

    Directory of Open Access Journals (Sweden)

    Anahita Sanaei Dashti

    2012-03-01

    Full Text Available Background: Brucellosis is a world-wide disease, which has a diverse clinical manifestation, and its diagnosis has to be proven by laboratory data. Serum agglutination test (SAT is the most-widely used test for diagnosing brucellosis. The enzyme linked immunosorbent assay (ELISA can also determine specific antibody classes against brucella. It is a sensitive, simple and rapid test, which could be an acceptable alternative to SAT with fewer limitations, however, like any other new test it should be further evaluated and standardized for various populations. This study was planned to determine an optimal cut-off point, for ELISA which would offer maximum sensitivity and specificity for the test when compared to SAT.Methods: Four hundred and seven patients with fever and other compatible symptoms of brucellosis were enrolled in the study. Serum agglutination test, 2-Mercaptoethanol test, and ELISA were performed on their sera. Results: The cut-off point of 53 IU/ml of ELISA-IgG yielded the maximal sensitivity and specificity comparing to the other levels of ELISA-IgG, and was considered the best cut off-point of ELISA-IgG to diagnose acute brucellosis. At this cut-off, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 84.09%, 85.38%, 62.20, 94.90, 5.75, 0.18, respectively.Conclusion: The best cut-off point of ELISA-IgG is 53 IU/ml, which yields the maximal sensitivity and specificity to diagnose acute brucellosis.

  9. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva

    International Nuclear Information System (INIS)

    Oehninger Gatti, C.; Buzo Del Puerto, R.; Chouza Antelo, C.; Scotti Bianchi, C.; Cibils, D.; Alcantara Pelaez, J.; Gomez, A.; Heuguerot Oliveira, C.

    1994-01-01

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [es

  10. Clinical usefulness of serum free light chains measurement in patients with multiple myeloma: comparative analysis of two different tests

    Directory of Open Access Journals (Sweden)

    Tadeusz Kubicki

    2017-01-01

    Full Text Available Introduction: There are two commercially available tests for measurement of serum free light chains (sFLC in multiple myeloma (MM patients – Freelite and N Latex FLC. The aim of this study was to perform an assessment and direct comparison of the usefulness of the methods in routine clinical practice.Methods: 40 refractory/relapsed MM patients underwent routine disease activity assessment studies, along with sFLC analysis using both assays. Correlation and concordance between the tests and sensitivity of studied methods of sFLC assessment were established. Special attention was focused on sFLC results in patients finally evaluated after completing the treatment. Results: A weak correlation for the measurement of both κ [Passing–Bablok slope (PB = 0.7681] and λ chains [(PB = 1.542] was found. Using Bland–Altman plots, a bias of 0.0467 (κ and -0.2133 (λ between the measurements was documented. The concordance coefficient equaled 0.87 for κ, 0.62 for λ and 0.52 for κ/λ ratio. Ten patients had an abnormal Freelite assay κ/λ ratio and normal N Latex FLC κ/λ ratio. Three of these patients had negative serum protein electrophoresis results and fulfilled diagnostic criteria of stringent complete remission (sCR according to N Latex FLC (but not according to Freelite. When the κ/λ ratio obtained by both methods was compared to patients’ serum/urine protein electrophoresis and immunofixation results, sensitivity of Freelite and N Latex FLC was established to be 62.5% and 41%, respectively. Conclusions: There was no strong correlation or concordance between the two assays, and the sensitivity in terms of sFLC detection was different. This may cause problems when diagnosis of sCR is considered.

  11. Protein electrophoresis - serum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003540.htm Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  12. Optimization of Diagnostic Elisa - Based Tests for the Detection of Auto-Antibodies Against Tumor Antigens in Human Serum

    Directory of Open Access Journals (Sweden)

    Daria Štefatić

    2008-08-01

    Full Text Available Colorectal cancer is one of the most common cancer types worldwide and it continues to be a serious public health problem. Early detection and diagnosis are of great importance in cancer management. At present, diagnostic blood tests are based on the detection of tumor-associated markers such as carcinoembryonic antigen (CEA, the cancer antigen CA19-9 for gastrointestinal cancer, CA15-3 for breast cancer or CA125 for ovarian cancer. The lack of sensitivity and specificity of these markers prevents their general use in cancer screening of an average risk population. Therefore, new cancer biomarkers or better screening methods are necessary to improve the diagnostics of the disease. This study was directed to the optimization of a diagnostic, enzyme linked immunosorbent assay (ELISA based test to identify and validate new serum markers, such as extracellular Protein Kinase A (ecPKA and Nicotinamide A-Meth- yltransferase (NNMT. In this type of assay, the cancer antigens are quantified indirectly - by detecting the presence of auto-antibodies against tumor proteins in human serum. The result of the optimization and validation process was in the case of ecPKA a reproducible and stable assay. In case of NNMT the assay was probably not sensitive enough.

  13. Evaluation of the Luciferase Assay-Based In Vitro Elicitation Test for Serum IgE

    Directory of Open Access Journals (Sweden)

    Ryosuke Nakamura

    2012-01-01

    Results: The area under the ROC curves was highest in the EXiLE test (0.977, followed by CAP-FEIA (0.926 and degranulation (0.810. At an optimal cutoff range (1.648-1.876 calculated from the ROC curve of the EXiLE test, sensitivity and specificity were 0.944 and 0.917, respectively. A 95% positive predictive value was given at a cutoff level of 2.054 (fold increase in luciferase expression by logistic regression analysis. Conclusions: In contrast to in vivo tests, the EXiLE test appears to be a useful tool in diagnosing patients suspected of having IgE-dependent EW allergy without the risk of severe systemic reactions.

  14. A large-scale radiometric micro-quantitative complement fixation test for serum antibody titration

    International Nuclear Information System (INIS)

    Bengali, Z.H.; Levine, P.H.; Das, S.R.

    1980-01-01

    A micro-quantitative complement fixation (CF) procedure based on 51 Cr release is described. The method employs 50% hemolysis as end point and the alternation equation to calculate the amount of complement involved in the hemolytic reaction. Compared to the conventional CF tests, the radiometric procedure described here is very precise and consistently reproducible. Also, since only 3 4-fold dilutions of sera are used for the titration of antibodies over a wide range of concentrations, the test is very concise and is economical to perform. Its format is amenable to automation and computerization. This radioimetric CF procedure is thus most useful for large-scale immunological research and epidemiological surveilance studies. (Auth.)

  15. Acute Changes in Creatine Kinase Serum Levels in Adults Submitted a Static Stretching and Maximal Strength Test

    Directory of Open Access Journals (Sweden)

    M.G. Bara Filho

    2008-01-01

    Full Text Available Strength and flexibility are common components of a training program and their maximal values are obtained through specific tests. However, little information about the damage effect of these training procedures in a skeletal muscle is known. Objective: To verify a serum CK changes 24 h after a sub maximal stretching routine and after the static flexibility and maximal strength tests. Methods: the sample was composed by 14 subjects (man and women, 28 ± 6 yr. physical education students. The volunteers were divided in a control group (CG and experimental group (EG that was submitted in a stretching routine (EG-ST, in a maximal flexibility static test (EG-FLEX and in 1-RM test (EG-1-RM, with one week interval among tests. The anthropometrics characteristics were obtained by digital scale with stadiometer (Filizola, São Paulo, Brasil, 2002. The blood samples were obtained using the IFCC method with reference values 26-155 U/L. The De Lorme and Watkins technique was used to access maximal maximal strength through bench press and leg press. The maximal flexibility test consisted in three 20 seconds sets until the point of maximal discomfort. The stretching was done in normal movement amplitude during 6 secons. Results: The basal and post 24 h CK values in CG and EG (ST; Flex and 1 RM were respectively 195,0 ± 129,5 vs. 202,1 ± 124,2; 213,3 ± 133,2 vs. 174,7 ± 115,8; 213,3 ± 133,2 vs. 226,6 ± 126,7 e 213,3 ± 133,2 vs. 275,9 ± 157,2. It was only observed a significant difference (p = 0,02 in the pre and post values inGE-1RM. Conclusion: only maximal strength dynamic exercise was capable to cause skeletal muscle damage.

  16. Patch testing and allergen-specific serum IgE and IgG antibodies in the diagnosis of canine adverse food reactions.

    Science.gov (United States)

    Bethlehem, Simone; Bexley, Jennifer; Mueller, Ralf S

    2012-02-15

    Adverse food reaction (AFR) is a common differential diagnosis for pruritic dogs. The only way to diagnose AFR is an elimination diet of 6-8 weeks with a protein and a carbohydrate source not previously fed. In humans, patch testing has been shown to be a useful tool to diagnose food allergies. In veterinary medicine, serum food allergen-specific antibody testing is widely offered to identify suitable ingredients for such diets. The aim of this study was to determine sensitivity, specificity, negative and positive predictability of patch testing with and serum antibody testing for a variety of common food stuffs. Twenty-five allergic dogs underwent an elimination diet and individual rechallenge with selected food stuffs, food patch testing and serum testing for food-antigen specific IgE and IgG. Eleven clinically normal control dogs only were subjected to patch and serum testing. The sensitivity and specificity of the patch test were 96.7 and 89.0% respectively, negative and positive predictability were 99.3 and 63.0%. For IgE and IgG the sensitivity was 6.7 and 26.7%, specificity were 91.4 and 88.3%, the negative predictive values 80.7 and 83.7% and the positive predictive values were 15.4 and 34.8%. Based on these results, a positive reaction of a dog on these tests is not very helpful, but a negative result indicates that this antigen is tolerated well. We conclude that patch testing (and to a lesser degree serum testing) can be helpful in choosing ingredients for an elimination diet in a dog with suspected AFR. Copyright © 2012. Published by Elsevier B.V.

  17. Screening and Monitoring Coeliac Disease: Multicentre Trial of a New Serum Antibody Test Kit

    Directory of Open Access Journals (Sweden)

    Peter L. Devine

    1994-01-01

    average interassay CV was 6.4% for IgA and 4.3% for IgG (n=3. By defining a positive te st as both IgA and IgG elevated, a sensitivity of 93% in untreated coeliacs (n=75 was observed. The corresponding specificities in healthy adults (n=130 and healthy children (n=77 were >99% and 100% respectively, while in patients with other gastrointestinal disorders (disease controls the specificity was 94% (n=129. The test was also useful in monitoring patients, with anti-gliadin IgA and IgG falling for up to a year after commencing a gluten-free diet (GFD (12 adults. In some patients however, antibody levels did not reach the normal cutpoint after many months on a GFD, which may reflect the patients ' poor adherence to their gluten free diet. The test was superior to the Pharmacia anti-gliadin ELISA, and should be useful as an aid to the diagnosis of coeliac disease, as well as in the follow-up of treated patients.

  18. Elevated serum CA 19-9 at screening tests: underlying conditions and role of abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang [University of Louisville, Department of Radiology and Molecular Imaging Research Center, Louisville, KY (United States); Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Kim, Se Hyung [Seoul National University Hospital, Department of Radiology and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Kim, Soo Young [Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Bundang CHA Hospital, Department of Radiology, Bundang (Korea, Republic of)

    2014-10-15

    To investigate underlying conditions of patients with elevated CA 19-9 at screening tests and to evaluate diagnostic performance of abdominopelvic CT. One hundred and thirteen patients with elevated CA 19-9 (>37 U/ml) who underwent abdominopelvic CT in a screening program were selected. Underlying conditions were determined by reviewing all available data and follow-up records. Patients were categorized into malignancy, benign, and normal/non-related disease groups. Their mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml were compared. Diagnostic sensitivity of CT for detecting underlying conditions of elevated CA 19-9 was analysed. Seventeen patients (17/113, 15 %) had 17 elevated CA 19-9-related malignancies, and 55 patients (55/113, 48.7 %) had 70 benign diseases. Mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml in the malignancy group were significantly higher than in the two other groups. CT detected all except one malignant lesion with a detection sensitivity of 94.1 % (16/17). Of 70 CA 19-9-related benign diseases, CT detected 34 benign diseases (48.6 %) providing an alternative diagnosis for elevated CA 19-9. Abdominopelvic CT is not only useful in detecting malignancies, but can also diagnose alternative benign causes of elevated CA 19-9 in asymptomatic screening tests. (orig.)

  19. Relationship between Serum Levels of Metalloproteinase-8 and Tissue Inhibitor of Metalloproteinases-1 and Exercise Test Results in Postmenopausal Women

    Directory of Open Access Journals (Sweden)

    J. Mieczkowska

    2016-01-01

    Full Text Available Physical activity as a part of the lifestyle is a significant factor influencing health condition. Exercises that require stamina are of particular importance. Oxygen metabolism, which is a significant part of all longer training processes, has an influence on cardiovascular and respiratory system functioning as well as all the processes taking part in maintenance of efficient homeostasis. Presentation of the correlation between exercise test results and MMP-8 (metalloproteinase-8 and TIMP-1 (tissue inhibitor of metalloproteinases-1 levels was attempted in this work. MMP-8 is a proteolytic enzyme taking part in progression of diseases related to process of ageing. 62 healthy women in postmenopausal period were qualified for the study (mean age: 54±3.6. There was exercise test on the treadmill according to Bruce’s protocol performed. MMP-8 and TIMP-1 serum levels were measured. There was statistically important correlation between increased level of MMP-8 and increased level of TIMP-1 with lower results of exercise test observed. The conducted study provides further biochemical arguments for prophylactic role of physical activity, which lowers the risk of noninfectious diseases, typical for middle adulthood, by influencing physical capacity.

  20. Sequential combined test, second trimester maternal serum markers, and circulating fetal cells to select women for invasive prenatal diagnosis.

    Directory of Open Access Journals (Sweden)

    Paolo Guanciali Franchi

    Full Text Available From January 1st 2013 to August 31st 2016, 24408 pregnant women received the first trimester Combined test and contingently offered second trimester maternal serum screening to identify those women who would most benefit from invasive prenatal diagnosis (IPD. The screening was based on first trimester cut-offs of ≥1:30 (IPD indicated, 1:31 to 1:899 (second trimester screening indicated and ≤1:900 (no further action, and a second trimester cut-off of ≥1:250. From January 2014, analysis of fetal cells from peripheral maternal blood was also offered to women with positive screening results. For fetal Down syndrome, the overall detection rate was 96.8% for a false-positive rate of 2.8% resulting in an odds of being affected given a positive result (OAPR of 1:11, equivalent to a positive predictive value (PPV of 8.1%. Additional chromosome abnormalities were also identified resulting in an OAPR for any chromosome abnormality of 1:6.6 (PPV 11.9%. For a sub-set of cases with positive contingent test results, FISH analysis of circulating fetal cells in maternal circulation identified 7 abnormal and 39 as normal cases with 100% specificity and 100% sensitivity. We conclude that contingent screening using conventional Combined and second trimester screening tests is effective but can potentially be considerably enhanced through the addition of fetal cell analysis.

  1. Autologous serum skin test as an indicator of chronic autoimmune urticaria in a tertiary care hospital in South India.

    Science.gov (United States)

    Vikramkumar, Adaikalampillai Ganapathy; Kuruvila, Sheela; Ganguly, Satyaki

    2014-12-01

    Autologous serum skin test (ASST) is a simple in-vivo clinical test for the detection of basophil histamine releasing activity and to diagnose chronic autoimmune urticaria (CAU) among chronic spontaneous urticaria (CSU) patients. Diagnosing these patients is also important as they may need high doses of antihistamines and systemic corticosteroids during acute exacerbations. The aim of this study is to study the prevalence of CAU among cases of CSU by using ASST. This was a cross-sectional study done among 48 patients presenting with CSU. Detailed history, physical examination and routine investigations were recorded for all patients. ASST was done on all the 48 patients. Of the 48 patients included in the study, 20 patients (41.6%) were ASST positive, while the remaining 28 (58%) were ASST negative. The median duration of disease in both ASST positive and negative patients was 1 year. ASST positivity was higher (66.6%) among patients with a history of round shaped weals, though not statistically significant. ASST positivity was seen in 5 (71.4%) out of seven patients with systemic involvement, which was again not statistically significant. Our study did not show any significant difference between patients with and without antibodies regarding mean age and sex distribution, clinical morphology of individual weals, duration, severity, systemic symptoms, angioedema, atopy, and association with other autoimmune conditions.

  2. Validation of basophil histamine release against the autologous serum skin test and outcome of serum-induced basophil histamine release studies in a large population of chronic urticaria patients

    DEFF Research Database (Denmark)

    Platzer, M H; Grattan, C E H; Poulsen, Lars K.

    2005-01-01

    the immunoglobulin E (IgE) or the high affinity IgE receptor (FcepsilonRI) and serum-induced histamine release (HR) from basophils and mast cells. We have examined the correlation between the ASST and a new basophil histamine-releasing assay (the HR-Urtikaria test) in a group of well-characterized CU patients...... and subsequently determined the frequency of HR-Urticaria-positive sera from a larger population of CU patients....

  3. The changing and its interaction of determining serum gastrin levels and helicobacter pylori test during chronic atrophic gastritis into gastric cancer

    International Nuclear Information System (INIS)

    Jing Weijuan; Yang Yongqing

    2009-01-01

    Objective: To study the changing and its interaction of determining serum gastrin levels and Helicobacter pylori test during chronic atrophic gastritis into gastric cancer. Methods: RIA and 13 C-urea breath test ( 13 C-UBT) determined the Gs levels and Hp infection rate in 63 rate cases (first visit) patients, 48 cases (after one year return visit) patients, 35 cases (after three year return visit) patients and 30 cases (after five years return visit) patients with CAG 90 cases patients with gastric cancer (and different position) and 61 cases normal controls. They all were done study compared. Results: Serum Gs levels in 63 cases (first visit) patients, 48 cases (after one year return visit) patients, 35 cases (after three year return visit) patients and 30 cases (after five years return visit) patient with CAG were significantly higher (t=4.716, 5.218, 5.624, 6.179, 6.5772, all P 0.05). Serum Gs levels in 90 cases with gastric cancer (and different position) was significantly higher (t=4.221, P<0.05; t=4.436, P<0.01) than 61 cases normal controls and the highest serum Gs level was found in cancer of cardia and fundus. And Hp infection rate was 88.8%. Conclusion: The early diagnosis on gastric cancer was very important by determining serum Gs and Hp infection rate. (authors)

  4. The correlation between histological gastritis staging- 'OLGA/OLGIM' and serum pepsinogen test in assessment of gastric atrophy/intestinal metaplasia in China.

    Science.gov (United States)

    Wang, Xiaoteng; Lu, Bin; Meng, Lina; Fan, Yihong; Zhang, Shuo; Li, Meng

    2017-08-01

    Serum pepsinogen (PG) test, as an indicator of gastric mucosal atrophy, reflects the functional and morphologic status of gastric mucosal and it is suggested to serve as a useful predictive marker for patients with gastric cancer (GC). The available classifications of gastritis, known as the Operative Link on Gastritis Assessment (OLGA) and Operative Link on Gastritis Intestinal Metaplasia (OLGIM), integrating the severity and topography of atrophy/intestinal metaplasia (IM), have been gradually accepted and used in screening for GC in recent years. To assess whether serum pepsinogen test, including PGI, PGII, PGI/PGII and gastrin-17 (G-17) could reflect the extent and topography of gastric mucosal atrophy/IM. Furthermore, to discuss the relationship between OLGA/OLGIM staging system and serum pepsinogen test in assessment of gastric atrophy/IM. The OLGA/OLGIM ranks the gastric staging according to both the topography and the severity of gastric atrophy/IM. A retrospective study was conducted with 331 patients who underwent endoscopy with consecutive biopsy sampling and reassessed according to OLGA/OLGIM staging system. Serum pepsinogen test, including PGI, PGII, PGI/PGII and G-17, as well as serological Helicobacter pylori (Hp) antibody were also measured. Results were presented as gastritis stage, serum pepsinogen level and Hp status. Baseline characteristics were compared using analysis of variance (ANOVA) test for continuous data and Pearson's χ 2 test for categorical data. A logistic regression model was used for the correlation analysis between OLGA/OLGIM and serological pepsinogen test. A total of 177 non-atrophic gastritis and 154 atrophic gastritis were analyzed, among which 40 were antrum atrophy, 32 were corpus atrophy and 82 were pan-atrophy. All patients were assessed applying the OLGA/OLGIM criteria with a mean age of 54.7 ± 10.8 years. Patients among OLGA/OLGIM Stage III-IV were presented with a lower level of serum PGI and PGI/PGII (p  15

  5. Comparison between sensitivity of autologous skin serum test and autologous plasma skin test in patients with Chronic Idiopathic Urticaria for detection of antibody against IgE or IgE receptor (FcεRIα).

    Science.gov (United States)

    Sajedi, Vahid; Movahedi, Masoud; Aghamohammadi, Asghar; Aghamohamadi, Asghar; Gharagozlou, Mohammad; Ghareguzlou, Mohammad; Shafiei, Alireza; Soheili, Habib; Sanajian, Nahal

    2011-06-01

    Intradermal injection of autologous serum and plasma elicit a cutaneous reactivity in almost 45-60% of patients with Chronic Idiopathic Urticaria (CIU). This reactivity is associated with the presence of auto antibodies against IgE or IgE receptors. This study was carried out to compare the cutaneous reactivity of autologous serum and plasma skin tests in a series of patients with CIU for diagnosis of auto antibodies against IgE or IgE receptor. Fifty eight patients with CIU were injected intradermally with autologous serum and plasma (anticoagulated by citrate). Histamine was used as positive control and normal saline as negative control. The study group was checked by routine laboratory tests (CBC, U/A etc), allergens with skin prick tests, and serum IgE level, and auto antibodies against thyroid as well. Duration of urticaria was another factor which was assessed.There was no significant difference between positive ASST and positive APST patients for the above mentioned tests. 77.6% of the patients were Positive for APST and 65.5% were ASST positive. Duration of urticaria was longer in patients with positive ASST and APST than ASST and APST negative patients, although the difference was not statistically significant.Autologus serum skin test (ASST) and autologous plasma skin test (APST) could be used for estimation of duration and severity of urticaria and planning for the treatment.

  6. Affinity study on bovine serum albumin's peptides to amphiphilic gold nanoparticles: A test of epitopes and non-epitopes

    Science.gov (United States)

    Yuan, Ming; Li, Wanrong; Yang, Mingming; Huang, Xiufeng; Bai, Zhijun; Liu, Yushuang; Cai, Weijun; Wang, Yuqin; Zhang, Feng

    2017-09-01

    It is an inevitable event that nanoparticles (NPs) will encounter proteins/peptides in nano-medicine, so it has been significant to know their interaction mechanism before in vivo applications. Previously, a 105-amino-acid sequence had been reported as the binding site between bovine serum albumin (BSA) and amphiphilic polymer coated gold nanoparticles (AP-AuNPs) along with a mortise-tenon joint hypothesis. This article tested the affinity difference between two epitope peptide sequences such as: LGEYGFQNALIVR (S1), DAFLGSFLYEYSR (S2) and one non-epitope peptide sequence as: FDEHVKLVNELTEF (S3). With the photoluminescent amino acid residues, the fluorescence quenching method based on the nanometal surface energy transfer (NSET) principle was able to study the thermodynamics of the current binding system. The binding constants (Ka) were determined and followed the order as: Ka-S1 > Ka-S2 >> Ka-S3. Moreover, Hill constants indicated that cooperativity only presented in the interactions of AP-AuNP with either S1 or S2, but not for S3. Moreover, gel electrophoresis, surface plasmon resonance, atomic force microscopy and three dimensional fluorescence microscopy were all also used to comprehensively analyse the binding interaction mechanism. These results further provided useful information to better understand the mortise-tenon joint, which might find applications to nanofabrication and biomedicine.

  7. HUBUNGAN AUTOLOGOUS SERUM SKIN TEST/ASST DENGAN KEPARAHAN KLINIS URTIKARIA KRONIK IDIOPATIK DI RSUP Dr. MOH HOESIN PALEMBANG

    Directory of Open Access Journals (Sweden)

    Suryadi Tjekyan

    2008-06-01

    Full Text Available Severity of Chronic Idiopathic Urticaria In RSUP Dr. Moh. Hoesin Palembang. There were differences in clinical finding among authors about autologous serum skin test/ASST result in chronic idiopathic urtikaria/CIU. Tanus et al (1996 reported there was no significant differences in clinical features of CIU, whereas Sabroe et al (1999 found significant differences in duration and itch of CIU patients. The prevalence of urticaria in General Hospital Dr. Moh. Hoesin Palembang showed increased tendency but there was no data about CIU and the severity of clinical features. The objectives of this study were to find out the significant correlation between ASST and severity of clinical features of CIU, and compared the difference of clinical features of CIU with and without positive ASST. This study was an observational analytic study, with cross sectional design. Fifty four subjects included in this study after following selection. Ethical approval was obtained from Bioethics and Humanities Unit, Faculty of Medicine Sriwijaya University and Dr. Moh. Hoesin Hospital Palembang. The clinical feature of 54 patients with CIU were evaluated. The data of physical examination and the anamnesis about clinical scores collected and analyzed using SPSS software and Spierman correlation was used to analyze the correlation between clinical severity of CIU and ASST result. Student’s t-test was used to analyze the differences in clinical severity of CIU with and without positive ASST. There was significant correlation between the severity clinical feature of CIU and ASST result (p=0,00 ; R=0,598. Patients with positif ASST results (46,3% had more duration of illness (0,00, higher pruritus score (0,00, and angiodema score (0,024. The CIU patients with severity clinical score of 27 (cut-off point, 11 times more likely to develop autoimmune urticaria than the patients with cut-off below 27 (p=0,00.

  8. Transcriptional regulation of the operon encoding stress-responsive ECF sigma factor SigH and its anti-sigma factor RshA, and control of its regulatory network in Corynebacterium glutamicum

    Czech Academy of Sciences Publication Activity Database

    Busche, T.; Šilar, Radoslav; Pičmanová, Martina; Pátek, Miroslav; Kalinowski, J.

    2012-01-01

    Roč. 13, č. 445 (2012), s. 445-464 ISSN 1471-2164 R&D Projects: GA ČR GC204/09/J015 Institutional research plan: CEZ:AV0Z50200510 Keywords : Corynebacterium glutamicum * ECF sigma factor * Anti-sigma factor Subject RIV: EE - Microbiology, Virology Impact factor: 4.397, year: 2012

  9. Evaluation of adrenal function in patients with hypothalamic and pituitary disorders : comparison of serum cortisol, urinary free cortisol and the human-corticotrophin releasing hormone test with the insulin tolerance test

    NARCIS (Netherlands)

    Dullaart, RPF; Pasterkamp, SH; Beentjes, JAM; Sluiter, WJ

    OBJECTIVE This study aimed to evaluate the performance of screening tests (serum cortisol and 24-h urinary free cortisol) and the human-corticotrophin releasing hormone (h-CRH) test in the assessment of adrenal function in patients with hypothalamic-pituitary disorders. DESIGN Summary receiver

  10. The test about blood serum capabilities in maintaining the quality of bull spermatozoa during storage in cep diluent at refrigerator temperature

    Science.gov (United States)

    Ducha, Nur

    2018-03-01

    The storage of spermatozoa requires a protective material from cold shock events and the presence of free radicals.In CEP diluent contain BSA, that was used as spermatozoa protection. This study aim was to examine the ability of cow blood serum in replacing BSA as spermatozoa protective in CEP diluent. Fresh semen from Limousin bull was diluted with CEP diluent + BSA as control, in the treatment group were CEP without BSA, but replaced with 3%, 5%, and 7% serum from fresh blood. Spermatozoa quality tests included motility and viability. The motility of spermatozoa was observed by two people using a light microscope with 200 X magnification at temperature of 37°C. The method of viability observation was eosin nigrosin staining, and observed under a light microscope with 400 X magnification. The results showed that the replacement of cow blood serum with various concentrations gave different effects on the quality of spermatozoa. The best motility and viability of the treatment group was at serum concentrations of 5% after eight days storage and was not significantly different from the controls. The conclusion in this study was cow blood serum can replace BSA in CEP diluents.

  11. Comparison of Salivary Anti Helicobacter pylori IgG with Serum IgG and Bacteriological Tests in Detecting Helicobacter pylori Infections

    Directory of Open Access Journals (Sweden)

    H Ghasemian safaei

    2005-01-01

    Full Text Available Background: This study was conducted to compare the efficacy of enzyme-linked immunosorbent assay (ELISA for detecting anti-Helicobacter pylori (H. pylori specific IgG antibodies in specimens of oral fluid and serum with bacteriological tests. Methods: Antral biopsy specimens, as well as serum and oral fluid samples were collected from 97 patients who underwent upper gastrointestinal endoscopy. The presence or absence of current H. pylori infection was determined by culture, histology and urease detection. Anti-H. pylori specific IgG was detected in serum and oral fluid, using an established lab-made, and a commercial ELISA kit. The obtained data were compared with results of bacteriological tests. Results: In all, 62 (64% of 97 patients were positive for H. pylori by one or more of the gold standard tests (culture, histology and urease detection. Lab-made enzyme-linked immunoassay of oral fluid had a sensitivity and specificity of 92% and 83% respectively. A sensitivity and specificity of 87% and 83%, respectively, was obtained with the commercial kit. Lab-made enzyme-linked immunoassay of serum samples had a sensitivity and specificity of 90% and 88%, respectively. A sensitivity of 86% and specificity of 86% was obtained with the commercial kit. Conclusion: Detection of anti-H. pylori specific IgG in oral fluid by ELISA is comparable in sensitivity and specificity with serum based methods. Oral fluid based ELISA could provide a reliable, non-invasive method for the diagnosis of H. pylori infection. Saliva testing may have a role in epidemiological studies. Keywords: Helicobacter pylori, ELISA, Oral fluid

  12. [Cultivation of a permanent fish cell line in serum-free media special experiences with a cytotoxicity test for waste water samples

    Science.gov (United States)

    Kohlpoth, Martin; Rusche, Brigitte

    1997-01-01

    The use of fetal calf serum (FCS) as standard medium additive for the cell cultivation must be regarded critically from the point of view of animal welfare as well as for scientific reasons and makes it necessary to look for alternatives. In the last years an in vitro cytotoxicity assay for the testing of industrial waste waters with the permanent fish cell line RTG-2 was established and pre-validated as an alternative to the fish test with the golden orfe. The application of FCS is also a special problem with regard to the testing of waste waters in a cytotoxicity test so that FCS-alternatives were tested. The RTG-2 cells were successfully adapted to the two solvents Basal Medium Supplement (BMS) and Ultroser-G (U-G) that are used to replace serum. The characterisation of these adapted cell lines showed no significant differences in growth rate, adhesion rate, viability and sensitivity to chemicals in comparison to the original RTG-2 cells. On the determination of the cytotoxicity of industrial waste waters the RTG-2 cells adapted to the BMS medium indicated a clearly higher toxicity of the waste water samples than the original RTG-2 cells. This result confirms the thesis that serum components react with waste water elements and thus change the bio-availability of toxic compounds.

  13. Evaluation of autologous serum skin test and skin prick test reactivity to house dust mite in patients with chronic spontaneous urticaria.

    Directory of Open Access Journals (Sweden)

    Zhiqiang Song

    Full Text Available BACKGROUND: Chronic spontaneous urticaria (CSU is a common skin disorder with etiology that is not well understood. METHODS: In this study, we evaluated the prevalence of autologous serum skin test (ASST and skin prick testing (SPT to house dust mite (HDM in 862 CSU cases in China. Clinical features, courses and treatment responses were also recorded. RESULTS: The prevalence of positive ASST was 46.3%, and patients aged 30-39 years had the highest positive rate (52.1%. Positive SPT to HDM was seen in 153 patients (17.7% with the highest positive rate (34.2% in patients aged 20 or less. Patients with positive ASST had higher urticaria activity scores (UAS (4.18±0.65 vs. 3.67±0.53 but lower positive rates of HDM (24.6% vs. 37.6%, as compared with those with negative ASST (odds ratio (OR 1.84, 95% CI 1.38-2.47. Patients could be categorized into four groups based on the results of ASST and SPT to HDM and patients with positive ASST and positive SPT to HDM had the highest disease activity scores, experienced higher frequencies of angioedema, diseases duration, and required higher dosage of loratadine every month, compared with other subgroups (P<0.0001. CONCLUSIONS: Patients with CSU showed varied responses of positive ASST and varied sensitivity to HDM, Patients with positive ASST and/or positive SPT had more disease activity compared with patients with negative ASST and/or negative SPT. Further classification can be made based on the result of SPT and ASST.

  14. The relation of germ cells per tubule in testes, serum inhibin B and FSH in cryptorchid boys

    DEFF Research Database (Denmark)

    Cortes, D; Thorup, Jørgen Mogens; Hogdall, E

    2007-01-01

    At bilateral orchiopexy bilateral biopsies may be indicated to determine fertility potential. It is currently unknown if the serum inhibin B levels at time of orchiopexy reflect the testicular status of the bilaterally cryptorchid child. The aim of this study was to relate the results of inhibin ...

  15. Zinc sulfate treatment of secondary male infertility associated with positive serum and seminal plasma anti-sperm antibody test

    Directory of Open Access Journals (Sweden)

    Haidar M. Jawad

    2013-03-01

    Conclusion: In conclusion, infertile men with elevated level of ASA and poor basic parameters of seminal fluid characters can be treated with zinc sulfate protocol with great chance for decreasing the level of serum and seminal plasma ASA, and alleviating the serious side effects associated with corticosteroids.

  16. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Science.gov (United States)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Wei-Jun; Leach, Robin J.; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-01-01

    Recently, selected reaction monitoring mass spectrometry (SRM-MS) has been more frequently applied to measure low abundance biomarker candidates in tissues and biofluids, owing to its high sensitivity and specificity, simplicity of assay configuration, and exceptional multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. Low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed good correlation in several independent clinical serum sample sets. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring candidate biomarkers in human blood, without the need to develop affinity reagents. Furthermore, the simultaneous measurement of multiple biomarkers, including the free and bound forms of PSA, can be performed in a single multiplexed analysis using high-resolution liquid chromatographic separation coupled with SRM-MS. PMID:22846433

  17. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  18. Evaluation of two new commercial tests for the diagnosis of acute dengue virus infection using NS1 antigen detection in human serum.

    Science.gov (United States)

    Dussart, Philippe; Petit, Laure; Labeau, Bhety; Bremand, Laetitia; Leduc, Alexandre; Moua, David; Matheus, Séverine; Baril, Laurence

    2008-08-20

    We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV) infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France), and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA), pan-E Dengue Early ELISA (Panbio - Brisbane, Australia)-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad). We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222) was 87.4% (95% confidence interval: 82.3% to 91.5%); that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4%) after 15 minutes and 82.4% (95% CI: 76.8% to 87.2%) after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%). The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8%) and a specificity of 97.9% (95% CI: 88.9% to 99.9%). Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.

  19. Evaluation of two new commercial tests for the diagnosis of acute dengue virus infection using NS1 antigen detection in human serum.

    Directory of Open Access Journals (Sweden)

    Philippe Dussart

    Full Text Available BACKGROUND: We compared the performance of two new commercial tests for the detection of dengue NS1 protein during the clinical phase of dengue virus (DENV infection-an immunochromatographic test allowing rapid detection of the NS1 antigen, Dengue NS1 Ag STRIP (Bio-Rad Laboratories - Marnes La Coquette, France, and a two-step sandwich-format microplate enzyme-linked immunosorbent assay (ELISA, pan-E Dengue Early ELISA (Panbio - Brisbane, Australia-with a one-step sandwich-format microplate ELISA, the Platelia Dengue NS1 Ag test (Bio-Rad. METHODS: We tested 272 serum samples from patients with dengue disease. Of these, 222 were from patients with acute infection of one of the four dengue serotypes, detected by RT-PCR and/or virus isolation. Forty-eight acute-phase serum samples from patients not infected with dengue virus were also included. RESULTS: The sensitivity of the Platelia Dengue NS1 Ag test on acute serum samples (n = 222 was 87.4% (95% confidence interval: 82.3% to 91.5%; that of Dengue NS1 Ag STRIP was 81.5% (95% CI: 75.8% to 86.4% after 15 minutes and 82.4% (95% CI: 76.8% to 87.2% after 30 minutes. Both tests had a specificity of 100% (97.5% CI, one-sided test: 92.6% to 100.0%. The pan-E Dengue Early ELISA had a sensitivity of 60.4% (95% CI: 53.4% to 66.8% and a specificity of 97.9% (95% CI: 88.9% to 99.9%. CONCLUSION: Our findings support the use of diagnostic tools based on the NS1 antigen detection for the diagnosis of acute DENV infection. The immunochromatographic test, Dengue NS1 Ag STRIP-the first rapid diagnostic test for DENV infection-was highly sensitive and specific, and would therefore be a suitable first-line test in the field. The pan-E Dengue Early ELISA was less sensitive than the Platelia test; this two-step ELISA should be combined with DENV IgM antibody detection for the diagnosis of DENV infection.

  20. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  1. RENAL FUNCTION TEST ON THE BASIS OF SERUM CREATININE AND UREA IN TYPE-2 DIABETICS AND NONDIABETICS

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-01-01

    Full Text Available Background: Type-2 diabetes mellitus has quickly become a global health problem due to rapidly increasing population growth, aging, urbanization and increasing prevalence of obesity and physical inactivity. Diabetic nephropathy is one of the major causes of chronic renal failure. Both serum urea and creatinine are widely used to assess the function of kidney. This study was conducted to observe the impaired renal function in type 2 diabetics and compare with non-diabetics controls. Method: To determine the incidence of renal dysfunction in diabetics in Nepalgunj medical college and Hospital , Nepalgunj , Banke, Nepal , blood samples from 100 diabetic subjects and 100 non-diabetic controls were taken between the period 1st February  , 2012  to  31st January , 2013 for investigation of  plasma glucose fasting(FPG, blood urea and serum creatinine. These biochemical parameters were determined by using a fully automated clinical chemistry analyzer. Results: Our findings showed that the level of blood urea (P<0.0001, 95%Cl and serum creatinine (P≈0.0004,95%Cl were significantly higher in type 2 diabetics as compared to non-diabetics in both male and female. There was no significant difference between diabetic male and female. 15 out of 100 diabetes samples have high urea level whereas 7 out of 100 had increased creatinine level. In control only 3 samples had high urea value and 1 had high creatinine level. There was statistical significant increased in urea level with increased in blood sugar level. Conclusion: Blood urea and creatinine is widely accepted to assess the renal functions. Good control of blood glucose level is absolute requirement to prevent progressive renal impairment.

  2. Characterization and in vivo regulon determination of an ECF sigma factor and its cognate anti-sigma factor in Nostoc punctiforme.

    Science.gov (United States)

    Bell, Nicole; Lee, Jamie J; Summers, Michael L

    2017-04-01

    Based on primary sequence comparisons and genomic context, Npun_F4153 (SigG)/Npun_F4154 (SapG) of the cyanobacterium Nostoc punctiforme were hypothesized to encode an ECF sigma factor/anti-sigma factor pair. Transcription of sigG increased in heterocysts and akinetes, and after EDTA treatment. Interaction between SigG and the predicted cytoplasmic domain of SapG was observed in vitro. A SigG-GFP translational fusion protein localized to the periphery of vegetative cells in vivo, but lost this association following heat stress. A sigG mutant was unable to survive envelope damage caused by heat or EDTA, but was able to form functional heterocysts. Akinetes in the mutant strain appeared normal, but these cultures were less resistant to lysozyme and cold treatments than those of the wild-type strain. The SigG in vivo regulon was determined before and during akinete differentiation using DNA microarray analysis, and found to include multiple genes with putative association to the cell envelope. Mapped promoters common to both arrays enabled identification of a SigG promoter-binding motif that was supported in vivo by reporter studies, and in vitro by run-off transcription experiments. These findings support SigG/SapG as a sigma/anti-sigma pair involved in repair of envelope damage resulting from exogenous sources or cellular differentiation. © 2017 John Wiley & Sons Ltd.

  3. Serum Adenosine Deaminase (ADA) Activity: A Novel Screening Test to Differentiate HIV Monoinfection From HIV-HBV and HIV-HCV Coinfections.

    Science.gov (United States)

    Abdi, Mohammad; Rahbari, Rizgar; Khatooni, Zahed; Naseri, Nima; Najafi, Adel; Khodadadi, Iraj

    2016-05-01

    CD4(+) cell count, the common HIV infection screening test, is costly and unable to differentiate HIV monoinfection from its concurrent infection with hepatitis B or C virus. We aimed to ascertain diagnostic value of serum adenosine deaminase (ADA) activity as a useful tool to differentiate HIV mono- and co-infection. Blood samples were collected from 30 HIV-HBV and 30 HIV-HCV coinfected patients, 33 HIV positive subjects, and 72 controls. CD4(+) cell count, serum total ADA (tADA), and ADA1, and ADA2 isoenzyme activities were determined and their sensitivity and specificity were computed. tADA and ADA2 activities were significantly higher and CD4(+) counts were markedly lower in all patients compared with controls. Strong inverse agreements between CD4(+) cell counts and both tADA and ADA2 activities were observed. Serum tADA and ADA1 activities showed the highest specificity and the highest sensitivity, respectively, for differentiating HIV monoinfection from HIV-HBV and HIV-HCV coinfections. We showed strong agreement and correlation between CD4(+) cell count and ADA enzyme activity. Based on high ADA sensitivity and specificity, it is concluded that determination of ADA activity might be a novel diagnostic tool to distinguish of HIV monoinfection from its coinfection with HBV or HCV. © 2015 Wiley Periodicals, Inc.

  4. Free leptin index and PAPP-A: a first trimester maternal serum screening test for pre-eclampsia

    DEFF Research Database (Denmark)

    Hedley, Paula L; Placing, Sophie; Wøjdemann, Karen

    2010-01-01

    BACKGROUND: Prophylaxis with low-dose aspirin may reduce the risk of pre-eclampsia (PE) if introduced in first trimester. The performance of first trimester maternal serum screening for PE using free leptin index (fLI) and PAPP-A, where fLI = leptin/leptin soluble receptor was studied. METHODS: F......: First trimester serum samples from 126 PE pregnancies and 289 control pregnancies were studied. fLI and PAPP-A were converted into gestational age and maternal weight independent log MoM values of PAPP-A and fLI. The screening performance of markers was studied by receiver......-operator-characteristics curves. The performance of population screening was estimated by Monte Carlo simulation. RESULTS: fLI was significantly (p controls [mean log MoM -0.0368 (SD: 0.3132)] and PAPP-A was significantly (p ....0133 (SD: 0.2661)] compared to controls [mean log MoM 0.0474 (SD: 0.2521)] in PE pregnancies. There was no correlation between fLI and PAPP-A in control or PE pregnancies. Combined fLI and PAPP-A screening for PE had estimated population detection rates of 22% and 35% for false positives rates of 6% and 12...

  5. Serum albumin and globulin analysis for hepatocellular carcinoma detection avoiding false-negative results from alpha-fetoprotein test negative subjects

    Science.gov (United States)

    Wang, Jing; Feng, Shangyuan; Lin, Juqiang; Zeng, Yongyi; Li, Ling; Huang, Zufang; Li, Buhong; Zeng, Haishan; Chen, Rong

    2013-11-01

    Surface-enhanced Raman spectroscopy (SERS) of serum albumin and globulin were employed to detect hepatocellular carcinoma (HCC). Tentative assignments of SERS bands show specific biomolecular changes associated with cancer development. These changes include a decrease in relative amounts of tryptophan, glutamine, glycine, and serine, indicating excessive consumption of amino acids for protein duplication. Principal component analysis was also introduced to analyze the obtained spectra, resulting in both diagnostic sensitivity and specificity of 100%. More importantly, it reveals that this method can detect HCC patients with alpha-fetoprotein negative test results, suggesting its great potential as a new alternative to detect HCC.

  6. Comparison of the Cerebrospinal Fluid (CSF) Toluidine Red Unheated Serum Test and the CSF Rapid Plasma Reagin Test with the CSF Venereal Disease Research Laboratory Test for Diagnosis of Neurosyphilis among HIV-Negative Syphilis Patients in China

    Science.gov (United States)

    Zhu, Lin; Gu, Xin; Peng, Rui-Rui; Wang, Cuini; Gao, Zixiao; Gao, Ying; Shi, Mei; Guan, Zhifang; Seña, Arlene C.

    2014-01-01

    In this study, we aimed to investigate the performance of nontreponemal antibody tests in cerebrospinal fluid (CSF) specimens from syphilis patients. From September 2009 to September 2012, CSF specimens were collected at the Shanghai Skin Disease Hospital in Shanghai, China, from 1,132 syphilis patients without HIV infection, including 154 with symptomatic and 56 with asymptomatic neurosyphilis. All of the CSF specimens underwent testing with a rapid plasma reagin (RPR) test, an RPR-V (commercial RPR antigen diluted 1:2 in 10% saline) test, the toluidine red unheated serum test (TRUST), and the Venereal Disease Research Laboratory (VDRL) test. Specificities, sensitivities, positive predictive values (PPVs), negative predictive values (NPVs), and kappa values were calculated to determine the performances of the tests. We compared results of the CSF-VDRL, CSF-RPR, CSF-RPR-V, and CSF-TRUST among patients with symptomatic and asymptomatic neurosyphilis who had reactive CSF-Treponema pallidum particle agglutination (TPPA) test results. Overall, the CSF-VDRL test was reactive in 261 patients (23.1%). There were no cases in which the CSF-VDRL was nonreactive and CSF-RPR, CSF-RPR-V, or CSF-TRUST was reactive. Agreement between the results of CSF-TRUST and CSF-RPR was almost perfect (κ = 0.861), with substantial agreement between the results of CSF-RPR and CSF-RPR-V (κ = 0.740). The sensitivities of CSF-VDRL, CSF-RPR, CSF-RPR-V, and CSF-TRUST were 81.4%, 76.2%, 79.5%, and 76.2%, respectively. Compared to CSF-VDRL, CSF-RPR, CSF-RPR-V, and CSF-TRUST had comparable PPVs and NPVs. However, the specificity of CSF-VDRL (90.3%) was significantly lower than those of the other tests (92.7 to 93.4%). Therefore, CSF-RPR, CSF-RPR-V, and CSF-TRUST can be considered alternative tests for neurosyphilis diagnosis in HIV-negative populations, particularly when the CSF-VDRL is not available. PMID:24335955

  7. Transcriptional regulation of the operon encoding stress-responsive ECF sigma factor SigH and its anti-sigma factor RshA, and control of its regulatory network in Corynebacterium glutamicum.

    Science.gov (United States)

    Busche, Tobias; Silar, Radoslav; Pičmanová, Martina; Pátek, Miroslav; Kalinowski, Jörn

    2012-09-03

    The expression of genes in Corynebacterium glutamicum, a Gram-positive non-pathogenic bacterium used mainly for the industrial production of amino acids, is regulated by seven different sigma factors of RNA polymerase, including the stress-responsive ECF-sigma factor SigH. The sigH gene is located in a gene cluster together with the rshA gene, putatively encoding an anti-sigma factor. The aim of this study was to analyze the transcriptional regulation of the sigH and rshA gene cluster and the effects of RshA on the SigH regulon, in order to refine the model describing the role of SigH and RshA during stress response. Transcription analyses revealed that the sigH gene and rshA gene are cotranscribed from four sigH housekeeping promoters in C. glutamicum. In addition, a SigH-controlled rshA promoter was found to only drive the transcription of the rshA gene. To test the role of the putative anti-sigma factor gene rshA under normal growth conditions, a C. glutamicum rshA deletion strain was constructed and used for genome-wide transcription profiling with DNA microarrays. In total, 83 genes organized in 61 putative transcriptional units, including those previously detected using sigH mutant strains, exhibited increased transcript levels in the rshA deletion mutant compared to its parental strain. The genes encoding proteins related to disulphide stress response, heat stress proteins, components of the SOS-response to DNA damage and proteasome components were the most markedly upregulated gene groups. Altogether six SigH-dependent promoters upstream of the identified genes were determined by primer extension and a refined consensus promoter consisting of 45 original promoter sequences was constructed. The rshA gene codes for an anti-sigma factor controlling the function of the stress-responsive sigma factor SigH in C. glutamicum. Transcription of rshA from a SigH-dependent promoter may serve to quickly shutdown the SigH-dependent stress response after the cells have

  8. Transcriptional regulation of the operon encoding stress-responsive ECF sigma factor SigH and its anti-sigma factor RshA, and control of its regulatory network in Corynebacterium glutamicum

    Directory of Open Access Journals (Sweden)

    Busche Tobias

    2012-09-01

    Full Text Available Abstract Background The expression of genes in Corynebacterium glutamicum, a Gram-positive non-pathogenic bacterium used mainly for the industrial production of amino acids, is regulated by seven different sigma factors of RNA polymerase, including the stress-responsive ECF-sigma factor SigH. The sigH gene is located in a gene cluster together with the rshA gene, putatively encoding an anti-sigma factor. The aim of this study was to analyze the transcriptional regulation of the sigH and rshA gene cluster and the effects of RshA on the SigH regulon, in order to refine the model describing the role of SigH and RshA during stress response. Results Transcription analyses revealed that the sigH gene and rshA gene are cotranscribed from four sigH housekeeping promoters in C. glutamicum. In addition, a SigH-controlled rshA promoter was found to only drive the transcription of the rshA gene. To test the role of the putative anti-sigma factor gene rshA under normal growth conditions, a C. glutamicum rshA deletion strain was constructed and used for genome-wide transcription profiling with DNA microarrays. In total, 83 genes organized in 61 putative transcriptional units, including those previously detected using sigH mutant strains, exhibited increased transcript levels in the rshA deletion mutant compared to its parental strain. The genes encoding proteins related to disulphide stress response, heat stress proteins, components of the SOS-response to DNA damage and proteasome components were the most markedly upregulated gene groups. Altogether six SigH-dependent promoters upstream of the identified genes were determined by primer extension and a refined consensus promoter consisting of 45 original promoter sequences was constructed. Conclusions The rshA gene codes for an anti-sigma factor controlling the function of the stress-responsive sigma factor SigH in C. glutamicum. Transcription of rshA from a SigH-dependent promoter may serve to quickly

  9. Validation of a serum neutralization test for detection of antibodies specific to cyprinid herpesvirus 3 in infected common and koi carp (Cyprinus carpio).

    Science.gov (United States)

    Cabon, J; Louboutin, L; Castric, J; Bergmann, S; Bovo, G; Matras, M; Haenen, O; Olesen, N J; Morin, T

    2017-05-01

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of a serious infective, notifiable disease affecting common carp and varieties. In survivors, infection is generally characterized by a subclinical latency phase with restricted viral replication. The CyHV-3 genome is difficult to detect in such carrier fish that represent a potential source of dissemination if viral reactivation occurs. In this study, the analytical and diagnostic performance of an alternative serum neutralization (SN) method based on the detection of CyHV-3-specific antibodies was assessed using 151 serum or plasma samples from healthy and naturally or experimentally CyHV-3-infected carp. French CyHV-3 isolate 07/108b was neutralized efficiently by sera from carp infected with European, American and Taiwanese CyHV-3 isolates, but no neutralization was observed using sera specific to other aquatic herpesviruses. Diagnostic sensitivity, diagnostic specificity and repeatability of 95.9%, 99.0% and 99.3%, respectively, were obtained, as well as a compliance rate of 89.9% in reproducibility testing. Neutralizing antibodies were steadily detected in infected carp subjected to restrictive or permissive temperature variations over more than 25 months post-infection. The results suggest that this non-lethal diagnostic test could be used in the future to improve the epidemiological surveillance and control of CyHV-3 disease. © 2016 John Wiley & Sons Ltd.

  10. Serum sickness

    Science.gov (United States)

    ... the problem should be stopped. Avoid using that medicine or antiserum in the future. ... Call your provider if you received medicine or antiserum in the last 4 weeks and have symptoms of serum sickness.

  11. Thyroxine determination in serum by radioimmunoassay and competitive protein-binding analysis (simultaneous study using four test kits)

    International Nuclear Information System (INIS)

    Wagner, K.

    1978-01-01

    Three commercial test kits for radioimmunological T 4 -determination have been tested (T 4 -RIA Abbott, RIA-mat T 4 , T 4 -RIA Henning). The RIA method has also been compared with a CPBA test (Tetralute) for routine application. 1) The results show that CPBA (Tetralute) is superior over the three radioimmuno-assays with regard to intra-assay variance. The T 4 -RIA Abbott has been inferior to the two other RIA under test and to the Tetralute with regard to inter-assay variance. 2) The four test kits show significant differences and considerable deviations from the given nominal values in comparison with the mean values of two control sera. A control for correctness does not seem to be appropriate as it cannot be decided which of the test kits yields the true value of T 4 content. No systematic difference has been observed between RIA and CPBA in the determination of T 4 in control sera. 3) No detectable difference has been found among the RIA-T 4 test kits and comparing them with the CBPA test regarding their diagnostic precision. A good correlation of T 4 values of euthyroid patients comparing the Tetralute and the three radioimmunological test kits. The mean values of euthyroid sera obtained by the three radioimmuno-assays and the Tetralute are not in agreement with each other. (orig.) [de

  12. EPINEPHRINE CONCENTRATION IN WILD BOAR (SUS SCROFA L. SERUM AFTER REPEATED ELISA TESTED FREEZE-THAWING CYCLES

    Directory of Open Access Journals (Sweden)

    Neška Vukšić

    2013-06-01

    Full Text Available Blood samples for determining of epinephrine concentration and biochemical parameters in the blood serum of wild boars were taken from 42 healthy wild boars, both sexes, during the hunting season. All animals in good condition, body weight 20 to 95 kg, were divided into two groups up to 50 kg (group A and up to 95 kg (Group B. Epinephrine concentration was determined by ELISA twice: one week after taking samples and a month after repeated freezing at -80°C. It was higher in relation to the reference value of domestic pigs and human (109.45 pg/ml in A and 119.54 pg/ml in B group. Repeated freezing and re-analysis after a month were resulted in lower concentrations of epinephrine (12% in young and 11.17% in adult animal, but without statistical significance (P>0.05. Biochemical analysis results’ show increased glucose and triglycerides concentrations compared to the reference values, while other indicators were observed within or slightly increased referring to the normal range. The correlation between glucose and epinephrine was not determined.

  13. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    Science.gov (United States)

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  14. Quantitation of species differences in albumin–ligand interactions for bovine, human and rat serum albumins using fluorescence spectroscopy: A test case with some Sudlow's site I ligands

    International Nuclear Information System (INIS)

    Poór, Miklós; Li, Yin; Matisz, Gergely; Kiss, László; Kunsági-Máté, Sándor; Kőszegi, Tamás

    2014-01-01

    Albumin, the most abundant plasma protein is an approximately 67 kDa sized water-soluble macromolecule. Since several drugs and xenobiotics circulate in the blood at least partially in albumin-bound form, albumin plays a key role in the pharmacokinetics/toxicokinetics of these chemicals. Most of the drugs and xenobiotics are Sudlow's site I ligands. In numerous studies, bovine serum albumin (BSA) is used for modeling albumin–ligand interactions and the results are extrapolated to human serum albumin (HSA). Furthermore, only limited information is available related to albumin–ligand interactions of different albumin species. Therefore, in our study, we have focused on the quantification of differences between bovine, human and rat serum albumin (RSA) using four Sudlow's site I ligands (luteolin, ochratoxin A, phenylbutazone and warfarin). Interactions were analyzed by fluorescence spectroscopy. Stability constants as well as competing capacities of the ligands were determined, and thermodynamic study was also performed. Our results highlight that there could be major differences between BSA, HSA and RSA in their ligand binding properties. Based on our observations we emphasize that in molecular aspects BSA behaves considerably differently from HSA or from albumins of other species therefore, it is strongly recommended to apply at least some confirmatory measurements when data obtained from other species are attempted to be extrapolated to HSA. -- Highlights: • Albumin–ligand interactions of human, bovine and rat albumins were studied. • Four Sudlow's site I ligands were tested by fluorescence spectroscopy. • Substantial differences were found in stability constants among albumin complexes. • Competing capacity of ligands showed major differences in the studied species. • Data obtained for BSA cannot be directly extrapolated to human albumin

  15. Serum Uric Acid Laboratory Test Request Patterns in Primary Care: How Panels May Contribute to Overutilization and Treatment of Asymptomatic Patients.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Leiva-Salinas, Carlos

    2017-12-22

    To study the variability in the request of serum uric acid (SUA) in primary care. A cross-sectional study was designed and conducted at a main core laboratory. Spanish laboratories were invited to report their number of serum glucose (SG) and SUA tests requested from primary care during 2014. A survey was sent to every participant in November 2016 regarding the inclusion of SUA in order profiles/panels. The ratio of SUA/SG requests (SUA/SG) was calculated and compared between regions, and laboratories depending on whether SUA was included or not in a health check profile. 110 laboratories participated in the study (59.8% Spanish population). The median SUA/SG ratio was 0.82 (IQR: 0.25), and 41 laboratories had a ratio over 0.9. There was a significant regional variability (P = .008). Laboratories where SUA was not included in the "health check profile" had lower SUA/SG indicators (P = .003). There was significant regional variability in the request of SUA, and an overall over-request. Different regional customs or habits and the inclusion of SUA in the health check profile were probable causes behind the observed over-request. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  16. Tests for Serum Transglutaminase and Endomysial Antibodies Do Not Detect Most Patients With Celiac Disease and Persistent Villous Atrophy on Gluten-free Diets: a Meta-analysis.

    Science.gov (United States)

    Silvester, Jocelyn A; Kurada, Satya; Szwajcer, Andrea; Kelly, Ciarán P; Leffler, Daniel A; Duerksen, Donald R

    2017-09-01

    Tests to measure serum endomysial antibodies (EMA) and antibodies to tissue transglutaminase (tTG) were developed to screen for celiac disease in patients consuming gluten. However, they are commonly used to monitor patients on a gluten-free diet (GFD). We conducted a meta-analysis to assess the sensitivity and specificity of tTG IgA and EMA IgA assays in identifying patients with celiac disease who have persistent villous atrophy despite a GFD. We searched PUBMED, EMBASE, BIOSIS, SCOPUS, clinicaltrials.gov, Science Citation Index, and Cochrane Library databases through November 2016. Inclusion criteria were studies of subjects with biopsy-confirmed celiac disease, follow-up biopsies, and measurement of serum antibodies on a GFD, biopsy performed on subjects regardless of symptoms, or antibody test results. Our analysis excluded subjects with refractory celiac disease, undergoing gluten challenge, or consuming a prescribed oats-containing GFD. Tests were considered to have positive or negative findings based on manufacturer cut-off values. Villous atrophy was defined as a Marsh 3 lesion or villous height:crypt depth ratio below 3.0. We constructed forest plots to determine the sensitivity and specificity of detection for individual studies. For the meta-analysis, a bivariate random effects model was used to jointly model sensitivity and specificity. Our search identified 5408 unique citations. Following review of abstracts, 442 articles were reviewed in detail. Only 26 studies (6 of tTG assays, 15 of EMA assays, and 5 of tTG and EMA assays) met our inclusion criteria. The most common reason studies were excluded from our analysis was inability to cross-tabulate histologic and serologic findings. The serum assays identified patients with persistent villous atrophy with high levels of specificity: 0.83 for the tTG IgA assay (95% CI, 0.79-0.87) and 0.91 for the EMA IgA assay (95% CI, 0.87-0.94). However, they detected villous atrophy with low levels of sensitivity: 0

  17. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva; Esclerosis multiple test de los 4 humores: liquido cefalorraquideo, suero, lagrimas y saliva

    Energy Technology Data Exchange (ETDEWEB)

    Oehninger Gatti, C; Buzo Del Puerto, R; Chouza Antelo, C; Scotti Bianchi, C; Cibils, D; Alcantara Pelaez, J; Gomez, A; Heuguerot Oliveira, C

    1994-12-15

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [Spanish] Se estudiaron 4 fluidos biologicos de facil acceso a la exploracion inmune (liquido cefalorraquideo, suero, lagrimas y saliva) en 25 pacientes con Esclerosis Multiple (EM) obtenidos durante un empuje clinico de la enfermedad. El nivel del receptor de Interleukina-2 soluble (RsIL-2) se encontro significativamente aumentado en por lo menos 3 de estos 4 fluidos, en comparacion con el de los controles normales. La sensibilidad y especificidad de su determinacion para el diagnostico de la afeccion, fue mayor que la de otros parametros inmunoquimicos - distribucion oligoclonal (DO) de inmunoglobulinas (Ig), disbalance de cadenas livianas - y estudios electrofisiologicos -potenciales evocados-. Este metodo es utilizado para establecer un diagnostico mas certero de la Esclerosis Multiple asi como tambien para monitorizar su actividad biologica junto con la resonancia magnetica nuclear (RMN)(Author)

  18. Risicoschatting voor Down syndroom en neuraalbuisdefecten door analyse van triple test parameters in maternaal serum 1999-2002

    NARCIS (Netherlands)

    Schielen PCJI; Elvers LH; Loeber JG; LIS

    2005-01-01

    In this report we describe a survey of over 14,000 triple test requests to estimate risks for Down syndrome and neural tube defect (NTD) pregnancies. They were collected between 1999 and 2002, from all the provinces in the Netherlands except Groningen, Friesland and Drenthe. This research was

  19. Risicoschatting voor Down syndroom/neuraalbuisdefecten door analyse van triple test parameters in maternaal serum 1995-1999

    NARCIS (Netherlands)

    Schielen PCJI; Hagenaars AM; Elvers LH; Loeber JG; LIS

    2003-01-01

    Between 1995 and 1999 the RIVM processed about 16,000 triple tests to estimate risks for the Down syndrome and neural tube defect pregnancies. This research was carried out on order of the Health Care Inspectorate of the Dutch Ministry of Health, Welfare, and Sport. The survey described here

  20. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  1. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  2. Association of serum orosomucoid with 30-min plasma glucose and glucose excursion during oral glucose tolerance tests in non-obese young Japanese women.

    Science.gov (United States)

    Tsuboi, Ayaka; Minato, Satomi; Yano, Megumu; Takeuchi, Mika; Kitaoka, Kaori; Kurata, Miki; Yoshino, Gen; Wu, Bin; Kazumi, Tsutomu; Fukuo, Keisuke

    2018-01-01

    Inflammatory markers are elevated in insulin resistance (IR) and diabetes. We tested whether serum orosomucoid (ORM) is associated with postload glucose, β-cell dysfunction and IR inferred from plasma insulin kinetics during a 75 g oral glucose tolerance test (OGTT). 75 g OGTTs were performed with multiple postload glucose and insulin measurements over a 30-120 min period in 168 non-obese Japanese women (aged 18-24 years). OGTT responses, serum adiponectin and high-sensitivity C reactive protein (hsCRP) were cross-sectionally analyzed by analysis of variance and then Bonferroni's multiple comparison procedure. Stepwise multivariate linear regression analyses were used to identify most important determinants of ORM. Of 168 women, 161 had normal glucose tolerance. Postload glucose levels and the area under the glucose curve (AUCg) increased in a stepwise fashion from the first through the third ORM tertile. In contrast, there was no or modest, if any, association with fat mass index, trunk/leg fat ratio, adiponectin, hsCRP, postload insulinemia, the Matsuda index and homeostasis model assessment IR. In multivariable models, which incorporated the insulinogenic index, the Matsuda index and HOMA-IR, 30 min glucose (standardized β: 0.517) and AUCg (standardized β: 0.495) explained 92.8% of ORM variations. Elevated circulating orosomucoid was associated with elevated 30 min glucose and glucose excursion in non-obese young Japanese women independently of adiposity, IR, insulin secretion, adiponectin and other investigated markers of inflammation. Although further research is needed, these results may suggest a clue to identify novel pathways that may have utility in monitoring dysglycemia within normal glucose tolerance.

  3. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Improved Screening Test for Idiopathic Infantile Hypercalcemia Confirms Residual Levels of Serum 24,25-(OH)2 D3 in Affected Patients.

    Science.gov (United States)

    Kaufmann, Martin; Morse, Nicole; Molloy, Billy Joe; Cooper, Donald P; Schlingmann, Karl Peter; Molin, Arnaud; Kottler, Marie Laure; Gallagher, J Christopher; Armas, Laura; Jones, Glenville

    2017-07-01

    CYP24A1 mutations are now accepted as a cause of idiopathic infantile hypercalcemia (IIH). A rapid liquid-chromatography tandem mass spectrometry (LC-MS/MS)-based blood test enabling measurement of the 25-OH-D 3 :24,25-(OH) 2 D 3 ratio (R) can identify IIH patients on the basis of reduced C24-hydroxylation of 25-OH-D 3 by CYP24A1 in vivo. Although values of this ratio are significantly elevated in IIH, somewhat surprisingly, serum 24,25-(OH) 2 D 3 remains detectable. The current study explores possible explanations for this including: residual CYP24A1 enzyme activity in individuals with certain CYP24A1 genotypes, expression of alternative C24-hydroxylases, and the possibility of isobaric contamination of the 24,25-(OH) 2 D 3 peak on LC-MS/MS. We employed an extended 20-min run time on LC-MS/MS to study serum vitamin D metabolites in patients with IIH due to mutations of CYP24A1 or SLC34A1; in unaffected heterozygotes and dialysis patients; in patients with vitamin D deficiency; as well as in normal subjects exhibiting a broad range of 25-OH-D levels. We identified 25,26-(OH) 2 D 3 as a contaminant of the 24,25-(OH) 2 D 3 peak. In normals, the concentration of 24,25-(OH) 2 D 3 greatly exceeds 25,26-(OH) 2 D 3 ; however, 25,26-(OH) 2 D 3 becomes more significant in IIH with CYP24A1 mutations and in dialysis patients, where 24,25-(OH) 2 D 3 levels are low when CYP24A1 function is compromised. Mean R in 30 IIH-CYP24A1 patients was 700 (range, 166 to 2168; cutoff = 140) as compared with 31 in 163 controls. Furthermore, patients possessing CYP24A1 L409S alleles exhibited higher 24,25-(OH) 2 D 3 levels and lower R (mean R = 268; n = 8) than patients with other mutations. We conclude that a chromatographic approach which resolves 24,25-(OH) 2 D 3 from 25,26-(OH) 2 D 3 produces a more accurate R that can be used to differentiate pathological states where CYP24A1 activity is altered. The origin of the residual serum 24,25-(OH) 2 D 3 in IIH patients appears to be

  5. Anxiety, Culture, and Expectations: Oncologist-Perceived Factors Associated With Use of Nonrecommended Serum Tumor Marker Tests for Surveillance of Early-Stage Breast Cancer.

    Science.gov (United States)

    Hahn, Erin E; Munoz-Plaza, Corrine; Wang, Jianjin; Garcia Delgadillo, Jazmine; Schottinger, Joanne E; Mittman, Brian S; Gould, Michael K

    2017-01-01

    Breast cancer offers several opportunities for reducing use of ineffective practices based on American Society of Clinical Oncology guidelines. We assessed oncologist-perceived factors associated with use of one such practice-serum tumor markers for post-treatment breast cancer surveillance-focusing on medical oncologists with high, medium, or low test use. Using a mixed-methods design, we identified patients who had been treated for early-stage breast cancer diagnosed between January 1, 2009, and December 31, 2012, within Kaiser Permanente Southern California and calculated the number of tests ordered from January 1, 2010, to December 31, 2014. We identified oncologists with high, medium, or low use and subsequently performed semistructured interviews. We used patient satisfaction data to assess association between pattern of use and satisfaction score. We identified 7,363 patients, with 40,114 tests ordered. High-use oncologists were defined as those ordering at least one test annually for 35% of patients or more, low-use oncologists as those ordering at least one test for 5% of patients or less; 42% of oncologists were high, 27% low, and 31% medium users. We interviewed 17 oncologists: six high, eight low, and three medium users. Factors associated with high use included: perceived patient anxiety, oncologist anxiety, belief that there was nothing else to offer, concern about satisfaction, patient competition, peer use, and system barriers. Factors associated with low use included: beliefs about consequences (eg, causes harms) and medical center culture (eg, collective decision to follow guidelines). We found no association between satisfaction score and pattern of use. Barriers to deimplementation are numerous and complex. Traditional strategies of practice change alone are unlikely to be effective. Multifaceted, multilevel strategies deployed to address patient-, clinician-, and system-related barriers may be required.

  6. Radioimmunoassay of cholylglycine in serum

    International Nuclear Information System (INIS)

    Wakushima, Tadashi; Yamanishi, Yasuhito; Hirayama, Chisato

    1979-01-01

    Serum levels of cholylglycines (CG) were determined by radioimmunoassay and that of total bile acids (TBA) by enzymatic method. In normal subjects, serum levels of CG, TBA and CG/TBA ratio were 0.6 +- 0.4 μM, 7 +- 2 μM, and 0.08 +- 0.06, respectively. They were increased markedly in acute hepatitis and moderately in chronic hepatitis and cirrhosis. Thus, measurement of serum CG as compared with serum TBA appears to be a sensitive liver test. (author)

  7. Total serum IgE level influences oral food challenge tests for IgE-mediated food allergies.

    Science.gov (United States)

    Horimukai, K; Hayashi, K; Tsumura, Y; Nomura, I; Narita, M; Ohya, Y; Saito, H; Matsumoto, K

    2015-03-01

    Probability curves predicting oral food challenge test (OFC) results based on specific IgE levels are widely used to prevent serious allergic reactions. Although several confounding factors are known to affect probability curves, the main factors that affect OFC outcomes are currently unclear. We hypothesized that an increased total IgE level would reduce allergic reactivity. Medical records of 337 and 266 patients who underwent OFCs for 3.5 g boiled hen's egg white and 3.1 ml raw cow's milk, respectively, were examined retrospectively. We subdivided the patients into three groups based on total IgE levels and age by percentile (75th percentiles), and logistic regression analyses were performed on each group. Patients with higher total IgE levels were significantly less responsive. In addition, age did not significantly affect the OFC results. Therefore, total IgE levels should be taken into account when predicting OFC results based on food-specific IgE levels. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Implications of failure to achieve a result from prenatal maternal serum cell-free DNA testing: a historical cohort study.

    Science.gov (United States)

    Chan, N; Smet, M-E; Sandow, R; da Silva Costa, F; McLennan, A

    2017-11-01

    To investigate the pregnancy outcomes in a cohort of women who failed to obtain a result in non-invasive prenatal testing (NIPT). Historical cohort study. A multicentre private practice in Sydney, Australia. Women who failed to obtain a result from NIPT (n = 131). The maternal characteristics, antenatal investigations and pregnancy outcomes for these women were compared with those who obtained a result at the same practice and to the general Australian obstetric population. Antenatal investigations: pregnancy-associated plasma protein-A (PAPP-A), free β-human chorionic gonadotrophin (β-hCG), placental growth factor (PlGF), uterine artery pulsatility index (PI), mean arterial pressure (MAP). Pregnancy outcomes: chromosomal abnormality, pre-eclampsia, gestational diabetes, small-for-gestational-age (SGA), preterm delivery. Only 1.1% of NIPT samples failed to return a result. This cohort was significantly older and had significantly increased weight compared with the general Australian obstetric population. Pregnancy outcomes were available for 94% of the cohort. There were significantly higher rates of chromosomal aneuploidies (6.5% versus 0.2%, P < 0.0001), pre-eclampsia (11% versus 1.5%, P < 0.0001) and gestational diabetes (23% versus 7.5%, P < 0.0001) compared with the general obstetric population. Rates of preterm delivery and SGA were elevated but did not reach significance. Antenatal investigations demonstrated decreased PAPP-A MoM (0.75 versus 1.14, P < 0.0001), decreased free β-hCG (0.71 versus 1.01, P < 0.0001) and increased uterine artery PI (1.79 versus 1.65, P = 0.02). Women who fail to obtain a result from NIPT are at increased risk of adverse pregnancy outcomes, in particular chromosomal aneuploidy, gestational diabetes and pre-eclampsia. None received. Women who fail to obtain a result from cell-free DNA NIPT are at increased risk of adverse pregnancy outcomes. © 2017 Royal College of Obstetricians and Gynaecologists.

  9. Accuracy of serum uric acid as a predictive test for maternal complications in pre-eclampsia: Bivariate meta-analysis and decision analysis

    NARCIS (Netherlands)

    Koopmans, Corine M.; van Pampus, Maria G.; Groen, Henk; Aarnoudse, Jan G.; van den Berg, Paul P.; Mol, Ben W. J.

    2009-01-01

    The aim of this study is to determine the accuracy and clinical value of serum uric acid in predicting maternal complications in women with pre-eclampsia. An existing meta-analysis on the subject was updated. The accuracy of serum uric acid for the prediction of maternal complications was assessed

  10. Accuracy of serum uric acid as a predictive test for maternal complications in pre-eclampsia : Bivariate meta-analysis and decision analysis

    NARCIS (Netherlands)

    Koopmans, C.M.; van Pampus, Maria; Groen, H.; Aarnoudse, J.G.; van den Berg, P.P.; Mol, B.W.J.

    The aim of this study is to determine the accuracy and clinical value of serum uric acid in predicting maternal complications in women with pre-eclampsia. An existing meta-analysis on the subject was updated. The accuracy of serum uric acid for the prediction of maternal complications was assessed

  11. Testing pigs of non-technified rearing farms for serum antibodies against Taenia solium in a region of the state of São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Gabriel A.M. Rossi

    2016-03-01

    Full Text Available Abstract: Taenia solium is a zoonotic tapeworm of great importance in developing countries, due to the occurrence of human taeniasis and cysticercosis. Pigs have an important role in the biological cycle of the parasite as intermediate hosts. The scientific literature has been describing risk factors associated with the occurrence of this disease that must be avoided in countries with poor sanitation, in order to reduce the exposure of swine to the parasite eggs. This research focused on testing pigs of non-technified rearing farms for serum antibodies against Taenia solium in the region of Jaboticabal municipality, in the state of São Paulo, Brazil. The found prevalence was 6.82% (CI 95% 4.18 - 9.45 at animal level and 28.87% (CI 95% 16.74 - 40.40 at herd level. These figures are probably associated with low technification adoption during animal rearing in the studied area, which increased the exposure of the animals to risk factors associated with the occurrence of Taenia solium complex. The results found based on serological evidences of swine cysticercosis in the studied region serves as a warning to public sanitary authorities to improve public health and control T. solium.

  12. Sensitivity, specificity and predictive probability values of serum agglutination test titres for the diagnosis of Salmonella Dublin culture-positive bovine abortion and stillbirth.

    Science.gov (United States)

    Sánchez-Miguel, C; Crilly, J; Grant, J; Mee, J F

    2018-06-01

    The objective of this study was to determine the diagnostic value of maternal serology for the diagnosis of Salmonella Dublin bovine abortion and stillbirth. A retrospective, unmatched, case-control study was carried out using twenty year's data (1989-2009) from bovine foetal submissions to an Irish government veterinary laboratory. Cases (n = 214) were defined as submissions with a S. Dublin culture-positive foetus from a S. Dublin unvaccinated dam where results of maternal S. Dublin serology were available. Controls (n = 415) were defined as submissions where an alternative diagnosis other than S. Dublin was made in a foetus from an S. Dublin unvaccinated dam where the results of maternal S. Dublin serology were available. A logistic regression model was fitted to the data: the dichotomous dependent variable was the S. Dublin foetal culture result, and the independent variables were the maternal serum agglutination test (SAT) titre results. Salmonella serology correctly classified 87% of S. Dublin culture-positive foetuses at a predicted probability threshold of 0.44 (cut-off at which sensitivity and specificity are at a maximum, J = 0.67). The sensitivity of the SAT at the same threshold was 73.8% (95% CI: 67.4%-79.5%), and the specificity was 93.2% (95% CI: 90.3%-95.4%). The positive and negative predictive values were 84.9% (95% CI: 79.3%-88.6%) and 87.3% (95% CI: 83.5%-91.3%), respectively. This study illustrates that the use of predicted probability values, rather than the traditional arbitrary breakpoints of negative, inconclusive and positive, increases the diagnostic value of the maternal SAT. Veterinary laboratory diagnosticians and veterinary practitioners can recover from the test results, information previously categorized, particularly from those results declared to be inconclusive. © 2017 Blackwell Verlag GmbH.

  13. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  14. Correlation between the concentration of serum polychlorinated biphenyls (PCBs) in pregnant cynomolgus monkeys and their offspring's behavioral scores in eye-contact test and finger maze learning test

    Energy Technology Data Exchange (ETDEWEB)

    Negishi, T. [Aoyama Gakuin Univ., Kanagawa (Japan); Takasuga, T. [Shimadzu Techno-Research Inc., Kyoto (Japan); Kawasaki, K. [Hoshi Univ., Tokyo (Japan); Kuroda, Y. [CREST Japan Science and Technology Corp., Saitama (Japan); Yoshikawa, Y. [The Univ. of Tokyo (Japan)

    2004-09-15

    A recent review suggested that pre- or perinatal exposure of developing fetuses to dioxins, the widespread environmental contaminants, such as polychrorinated biphenlys (PCBs), induce the irreversible abnormalities in the functions of central nervous system (CNS) in human. These chemicals can be transferred to each fetus and naonate transplacentally and lactationally in rhesus monkey. Several studies also reported the adverse effect of PCB on CNS development in rodents and monkeys as well as on behavior in rodents and monkeys. In the present study, we show a preliminary data about the correlation between the serum concentrations of PCBs in pregnant cynomolgus monkeys (Macaca fascicularis) and the scores of two behavioral tests, eye-contact test and four-step finger maze test, which evaluate consciousness against human observer and learning ability, respectively, in their offspring. This experimental surveillance system using non-human primates would be useful to predict the risk of PCBs exposure in human fetuses because of the similarities of cynomolgus monkey to human with regard to reproduction, developmental parameter, and others.

  15. Brief Report: Randomized, Double-Blind Comparison of Tenofovir Alafenamide (TAF) vs Tenofovir Disoproxil Fumarate (TDF), Each Coformulated With Elvitegravir, Cobicistat, and Emtricitabine (E/C/F) for Initial HIV-1 Treatment: Week 144 Results.

    Science.gov (United States)

    Arribas, José R; Thompson, Melanie; Sax, Paul E; Haas, Bernhard; McDonald, Cheryl; Wohl, David A; DeJesus, Edwin; Clarke, Amanda E; Guo, Susan; Wang, Hui; Callebaut, Christian; Plummer, Andrew; Cheng, Andrew; Das, Moupali; McCallister, Scott

    2017-06-01

    In 2 double-blind phase 3 trials, 1733 antiretroviral-naive adults were randomized to tenofovir alafenamide (TAF) or tenofovir disoproxil fumarate (TDF), each coformulated with elvitegravir/cobicistat/emtricitabine (E/C/F). At 144 weeks, TAF was superior to TDF in virologic efficacy, with 84.2% vs 80.0% having HIV-1 RNA TAF had less impact than TDF on bone mineral density and renal biomarkers. No participants on TAF had renal-related discontinuations vs 12 on TDF (P TAF vs 4 for TDF. There were greater increases in lipids with TAF vs TDF, with no difference in the total cholesterol to high-density lipoprotein ratio. For initial HIV therapy, E/C/F/TAF is superior to E/C/F/TDF in efficacy and bone and renal safety.

  16. Second Announcement - ESO/ST-ECF Workshop on NICMOS and the VLT: A New Era of High-Resolution Near-Infrared Imaging and Spectroscopy - May 26-27, 1998 - Hotel Baia di Nora, Pula, Sardinia, Italy

    Science.gov (United States)

    1998-03-01

    ST-ECF and ESO are organising in collaboration with the NICMOS IDT and STScI a workshop on near infrared imaging from space and ground. The purpose of the workshop is to review what has been achieved with the Near Infrared and Multi Object Spectrograph (NICMOS) on board of HST, what can be achieved in the remaining lifetime of the instrument, and how NICMOS observations can be optimised taking into account the availability of IR imaging and spectroscopy on ESO's Very large Telescope (VLT) in the near future. The meeting will be held in May 1998, about one year after science observations started with NICMOS, and about half a year before the Infrared Spectrometer and Array Camera (ISAAC) starts to operate on the VLT. Currently, it is expected that NICMOS will operate until the end of 1998.

  17. Relationship between CT scans and serum tests for diagnosing tuberculosis; Relacao entre imagens de tomografia computadorizada e exames sericos no diagnostico da tuberculose

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Marcela de; Pina, Diana R.; Giacomini, Guilherme; Alvarez, Matheus; Pavan, Ana Luiza M.; Pereira, Paulo C.M. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2014-07-01

    Tuberculosis (TB) is one of the oldest infectious diseases in the world and still affects humanity today. Since 1993, the World Health Organization (WHO) considers TB as a global emergency. The clinical history of the individual, the serum exams and particularly, the imaging examination of the thorax, are used for diagnostic confirmation and monitoring of disease. TB is a chronic disease that usually evolves with pulmonary sequelae that must be monitored. The exam of the image more precise to assess the radiological patterns found in these patients is high-resolution computed tomography (HRCT), which aids in medical diagnosis and permit the determination of the area affected by radiological abnormalities of pulmonary tuberculosis. The best known of such modifications by means of exams or more accurate techniques is of extreme importance. Therefore, this study aimed to show the quantification, performed by algorithms, of the areas affected by the radiological abnormalities of TB through the HRCT, and compared with serum exams. We studied 16 patients with confirmed diagnosis of TB. The serum exams evaluated included: hemoglobin, hematocrit, albumin, speed hemo sedimentation and C-reactive protein. With the values of serum exams we observed that patients have anemia, low albumin levels and inflammatory activity, corroborating imaging exams, which show severe impairment of lung area due to the inflammation caused by disease activity. (author)

  18. Serum paraoxonase 1 activity in dogs

    DEFF Research Database (Denmark)

    Rossi, Gabriele; Giordano, Alessia; Pezzia, Francesca

    2013-01-01

    Serum activity of paraoxonase (PON1) decreases during inflammation in many species. Little information is available on paraoxon-based tests and the possible role of PON1 in dogs.......Serum activity of paraoxonase (PON1) decreases during inflammation in many species. Little information is available on paraoxon-based tests and the possible role of PON1 in dogs....

  19. Comparison of the Cerebrospinal Fluid (CSF) Toluidine Red Unheated Serum Test and the CSF Rapid Plasma Reagin Test with the CSF Venereal Disease Research Laboratory Test for Diagnosis of Neurosyphilis among HIV-Negative Syphilis Patients in China

    OpenAIRE

    Zhu, Lin; Gu, Xin; Peng, Rui-Rui; Wang, Cuini; Gao, Zixiao; Zhou, Pingyu; Gao, Ying; Shi, Mei; Guan, Zhifang; Seña, Arlene C.

    2014-01-01

    In this study, we aimed to investigate the performance of nontreponemal antibody tests in cerebrospinal fluid (CSF) specimens from syphilis patients. From September 2009 to September 2012, CSF specimens were collected at the Shanghai Skin Disease Hospital in Shanghai, China, from 1,132 syphilis patients without HIV infection, including 154 with symptomatic and 56 with asymptomatic neurosyphilis. All of the CSF specimens underwent testing with a rapid plasma reagin (RPR) test, an RPR-V (commer...

  20. Free serum thyroxine

    International Nuclear Information System (INIS)

    Degrossi, O.J.; Altschuler, Noe; Cabrejas, M.L. de; Pinkas, Mirta; Garcia del Rio, Hernan

    1982-01-01

    The use of radiommunoassay (RIA) tehcniques has increased the diagnosis of thyroid functional alterations. A solid phase RIA method for free thyroxine (FT4) measurement was tested. Serum FT4, Total T4, T3 and TSH were determined by radioimmunoassay in 179 subjects. One hundred twenty two patients were normal (8 to 75 years old); FT4 was 1.42 +- 0.03 ng/100 ml (avg. value and std. error). In 27 cases of thyrotoxicosis the values were 4.66 +- 0.48 ng/100 ml and in 15 cases of hypothyroidism 0.50 +- 0.06 ng/100 ml (statistics probability [es

  1. Suggestions / contributions for the re-shaping of the European energy policy. Comparison between the ECF 'road-map 2050' scenario commissioned by Brussels and an extrapolation of the SLC-Negatep scenario at the European scale

    International Nuclear Information System (INIS)

    Acket, Claude; Bacher, Pierre

    2011-01-01

    The 'European Climate' Foundation and 'Sauvons le Climat' have proposed energy scenarios for Europe and for France, respectively, with the objectives of dividing by a factor 4 or 5 the CO 2 emissions. The objectives are similar, and so are the premises that success rests on decisive actions in all the sectors contributing to the emissions. Both scenario families call for a large improvement in energy efficiency, a massive use of renewable heat (biomass, solar etc.), and the substitution of electricity to fossil fuels in both their stationary uses (housing end tertiary sectors) and mobile uses (transport). This last requirement leads to a 50 % to 100 % increase in electricity demand by 2050. The two families diverge, however, on the means to produce this electricity: ECF calls for a massive use of renewable electricity (mainly wind an solar) and a supplement provided for by fossile energy with capture and sequestration of the CO 2 produced (CCS) and nuclear energy; a super grid connecting Southern Europe to Northern Europe has to be built to deal with the load variations, with additional combustion turbines as standby. SLC's Negatep scenarios call for a very large contribution of carbon-free (nuclear and (or) fossile with CCS) energies, and a supplement provided for by renewable electricity, the latter being limited by the existing grid capacities. The present work compares the different scenarios and their relative costs; it shows that the Negatep scenarios carry investments roughly half those of the scenarios with the largest renewable component, together with electricity costs significantly lower. In other words, a European energy policy along the lines advocated by ECF would entail particularly large capital investments and, in constant money, a two-fold increase in the cost of electricity by 2050 in Europe. And France would become a crossroad for European electricity and would have to harbour many high tension lines. The conclusion is that this situation should

  2. Ketones blood test

    Science.gov (United States)

    Acetone bodies; Ketones - serum; Nitroprusside test; Ketone bodies - serum; Ketones - blood; Ketoacidosis - ketones blood test ... fat cells break down in the blood. This test is used to diagnose ketoacidosis . This is a ...

  3. Myostatin inhibitors in sports drug testing: Detection of myostatin-neutralizing antibodies in plasma/serum by affinity purification and Western blotting.

    Science.gov (United States)

    Walpurgis, Katja; Thomas, Andreas; Schänzer, Wilhelm; Thevis, Mario

    2016-02-01

    Myostatin is a key regulator of skeletal muscle growth and inhibition of its signaling pathway results in an increased muscle mass and function. The aim of this study was to develop a qualitative detection assay for myostatin-neutralizing antibodies for doping control purposes by using immunological approaches. To detect different types of myostatin-neutralizing antibodies irrespective of their amino acid sequence, an immunological assay specific for antibodies directed against myostatin and having a human Fc domain was established. Affinity purification and Western blotting strategies were combined to allow extracting and identifying relevant analytes from 200 μL of plasma/serum in a non-targeted approach. The assay was characterized regarding specificity, linearity, precision, robustness, and recovery. The assay was found to be highly specific, robust, and linear from 0.1 to 1 μg/mL. The precision was successfully specified at three different concentrations and the recovery of the affinity purification was 58%. Within this study, an immunological detection assay for myostatin-neutralizing antibodies present in plasma/serum specimens was developed and successfully characterized. The presented approach can easily be modified to include other therapeutic antibodies and serves as proof-of-concept for the detection of antibody-based myostatin inhibitors in doping control samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  5. Evaluation of the Aptima HBV Quant assay vs. the COBAS TaqMan HBV test using the high pure system for the quantitation of HBV DNA in plasma and serum samples.

    Science.gov (United States)

    Schalasta, Gunnar; Börner, Anna; Speicher, Andrea; Enders, Martin

    2018-03-28

    Proper management of patients with chronic hepatitis B virus (HBV) infection requires monitoring of plasma or serum HBV DNA levels using a highly sensitive nucleic acid amplification test. Because commercially available assays differ in performance, we compared herein the performance of the Hologic Aptima HBV Quant assay (Aptima) to that of the Roche Cobas TaqMan HBV test for use with the high pure system (HPS/CTM). Assay performance was assessed using HBV reference panels as well as plasma and serum samples from chronically HBV-infected patients. Method correlation, analytical sensitivity, precision/reproducibility, linearity, bias and influence of genotype were evaluated. Data analysis was performed using linear regression, Deming correlation analysis and Bland-Altman analysis. Agreement between the assays for the two reference panels was good, with a difference in assay values vs. target 0.98). The two assays had similar bias and precision across the different genotypes tested at low viral loads (25-1000 IU/mL). Aptima has a performance comparable with that of HPS/CTM, making it suitable for use for HBV infection monitoring. Aptima runs on a fully automated platform (the Panther system) and therefore offers a significantly improved workflow compared with HPS/CTM.

  6. Correlative analysis of longitudinal changes in bronchoalveolar lavage, 67Gallium scanning, serum angiotensin-converting enzyme activity, chest x-ray, and pulmonary function tests in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Okada, Mitsuko; Takahashi, Hideki; Nukiwa, Toshihiro; Matsuoka, Rokuro; Furuse, Makoto; Kitamura, Satoshi; Kira, Shiro.

    1987-01-01

    Despite the relatively high cost and complicated procedures, Gallium-67 ( 67 Ga) scanning and bronchoalveolar lavage (BAL) are increasingly advocated as more sensitive indicators of disease activity in sarcoidosis than chest X-ray and serum angiotensin-converting enzyme activity (SACE). To evaluate the clinical usefulness of 67 Ga scanning and BAL, we followed 31 patients with pulmonary sarcoidosis, using these four parameters, at 9- to 24-month intervals over periods of 9 to 48 months. We obtained 68 complete evaluations. Close correlations were observed among chest X-ray, 67 Ga scanning, SACE, and the percent-age of lymphocytes in BAL fluid (p 67 Ga scanning and BAL are not necessarily indicated in the long-term management of pulmonary sarcoidosis. (author)

  7. Prediction of the outcome of growth hormone provocative testing in short children by measurement of serum levels of insulin-like growth factor I and insulin-like growth factor binding protein 3

    DEFF Research Database (Denmark)

    Juul, A; Skakkebaek, N E

    1997-01-01

    Serum levels of insulin-like growth factor I (IGF-I) and insulin-like growth factor binding protein 3 (IGFBP-3) reflect the secretion of endogenous growth hormone (GH) in healthy children and exhibit little diurnal variation, which makes them potential candidates for screening of GH deficiency (GHD......). We evaluated serum IGF-I and IGFBP-3 levels in relation to the outcome of GH provocative testing in 203 children and adolescents (111 boys and 92 girls) in whom GHD was suspected. A total of 1030 children served as control subjects. In children less than 10 years of age, IGF-I levels were below...... with a normal GH response (specificity 97.9%). Consequently the predictive value of a positive test result in prepubertal children was 88.8% for IGF-I and 90% for IGFBP-3. In children and adolescents between 10 and 20 years of age, IGF-I levels were below the cutoff limit in 34 of 46 children with GHD...

  8. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    Metabonomics offers a distinct advantage over other tests as it can be ... Metabolic profiling in heart disease has also been successfully ... resonances of the small metabolites showing fingerprints of serum metabolomic profile (Figure. 3).

  9. Quantitation of species differences in albumin–ligand interactions for bovine, human and rat serum albumins using fluorescence spectroscopy: A test case with some Sudlow's site I ligands

    Energy Technology Data Exchange (ETDEWEB)

    Poór, Miklós [Institute of Laboratory Medicine, University of Pécs, Ifjúság u. 13, Pécs H-7624 (Hungary); Li, Yin; Matisz, Gergely [Department of General and Physical Chemistry, University of Pécs, Pécs H-7624 (Hungary); János Szentágothai Research Center, Pécs H-7624 (Hungary); Kiss, László [Department of General and Physical Chemistry, University of Pécs, Pécs H-7624 (Hungary); Kunsági-Máté, Sándor [Department of General and Physical Chemistry, University of Pécs, Pécs H-7624 (Hungary); János Szentágothai Research Center, Pécs H-7624 (Hungary); Kőszegi, Tamás, E-mail: koszegit@freemail.hu [Institute of Laboratory Medicine, University of Pécs, Ifjúság u. 13, Pécs H-7624 (Hungary)

    2014-01-15

    Albumin, the most abundant plasma protein is an approximately 67 kDa sized water-soluble macromolecule. Since several drugs and xenobiotics circulate in the blood at least partially in albumin-bound form, albumin plays a key role in the pharmacokinetics/toxicokinetics of these chemicals. Most of the drugs and xenobiotics are Sudlow's site I ligands. In numerous studies, bovine serum albumin (BSA) is used for modeling albumin–ligand interactions and the results are extrapolated to human serum albumin (HSA). Furthermore, only limited information is available related to albumin–ligand interactions of different albumin species. Therefore, in our study, we have focused on the quantification of differences between bovine, human and rat serum albumin (RSA) using four Sudlow's site I ligands (luteolin, ochratoxin A, phenylbutazone and warfarin). Interactions were analyzed by fluorescence spectroscopy. Stability constants as well as competing capacities of the ligands were determined, and thermodynamic study was also performed. Our results highlight that there could be major differences between BSA, HSA and RSA in their ligand binding properties. Based on our observations we emphasize that in molecular aspects BSA behaves considerably differently from HSA or from albumins of other species therefore, it is strongly recommended to apply at least some confirmatory measurements when data obtained from other species are attempted to be extrapolated to HSA. -- Highlights: • Albumin–ligand interactions of human, bovine and rat albumins were studied. • Four Sudlow's site I ligands were tested by fluorescence spectroscopy. • Substantial differences were found in stability constants among albumin complexes. • Competing capacity of ligands showed major differences in the studied species. • Data obtained for BSA cannot be directly extrapolated to human albumin.

  10. Investigation and management of a raised serum ferritin.

    Science.gov (United States)

    Cullis, Jonathan O; Fitzsimons, Edward J; Griffiths, William Jh; Tsochatzis, Emmanouil; Thomas, D Wayne

    2018-05-01

    Serum ferritin level is one of the most commonly requested investigations in both primary and secondary care. Whilst low serum ferritin levels invariably indicate reduced iron stores, raised serum ferritin levels can be due to multiple different aetiologies, including iron overload, inflammation, liver or renal disease, malignancy, and the recently described metabolic syndrome. A key test in the further investigation of an unexpected raised serum ferritin is the serum transferrin saturation. This guideline reviews the investigation and management of a raised serum ferritin level. The investigation and management of genetic haemochromatosis is not dealt with however and is the subject of a separate guideline. © 2018 John Wiley & Sons Ltd.

  11. Leucine aminopeptidase blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003559.htm Leucine aminopeptidase blood test To use the sharing features on this page, ... Alternative Names Serum leucine aminopeptidase; LAP - serum Images Blood test References Chernecky CC, Berger BJ. Leucine aminopeptidase (LAP) - ...

  12. Removal of Lipid from Serum Increases Coherence between Brucellosis Rapid Agglutination Test and Enzyme-linked Immunosorbent Assay in Bears in Alaska, USA.

    Science.gov (United States)

    Godfroid, Jacques; Beckmen, Kimberlee; Helena Nymo, Ingebjørg

    2016-10-01

    In cases of chronic Brucella spp. infection, results of the rose bengal plate test (RBPT) and indirect enzyme-linked immunosorbent assay (ELISA) should be coherent, as reported in controlled conditions in the literature. We compared RBPT and ELISA results in 58 Alaska grizzly bears ( Ursus arctos horribilis), eight Kodiak brown bears ( Ursus arctos middendorffi), and six Alaska Peninsula brown bears ( Ursus arctos gyas). Of the 72 bears tested, 42 (58%) were ELISA positive and 53 (73%) were RBPT positive. However, the coherence between the tests was only fair (K=0.37, SE=0.11), suggesting that either the serologic results were not compatible with Brucella spp. infection or that there was a technical problem with the tests. To address a potential technical problem, we performed a 30-min chloroform/centrifugation cleanup. Following cleanup, the ELISA identified 43 positives (59%) and the RBPT identified 47 (65%), and the coherence between the tests was much improved (K=0.80, SE=0.07). We recommend cleaning wildlife sera with a high lipid content before performing RBPT and performing RBPT and ELISA in parallel to assess coherence. Our results suggest that Alaskan brown bears have been exposed to Brucella spp.

  13. Diagnostic informative value of gastroduodenal regulatory peptides of the blood serum on an empty stomach and after test breakfasts of various compositions

    International Nuclear Information System (INIS)

    Ablyazov, A.A.; Korot'ko, G.F.

    1992-01-01

    Gastrin, secretin and cholecystokinin were determined by a radioimmunoassay in healthy persons (19) and in patients with peptic ulcer (13) on an empty stomach and after test breakfasts with different nutrients. In the healthy persons the blood concentration of regulatory peptides was lower than in the patients. Breakfasts increased the concentrations of gastrin, secretin and cholecystokinin in the patients much more than in the controls. Some differences in changes of the blood concentration of peptides were noted with regard to a type of test breakfast. However differentiated reactions of the endocrine apparatus of the gastroduodenal complex in response to the breakfasts were not a reliable functional and diagnostic criterion

  14. Membrane potential, serum calcium and serum selenium decrease in preeclampsia subjects in Owerri

    Directory of Open Access Journals (Sweden)

    Johnkennedy Nnodim

    2017-08-01

    Full Text Available Background Pre-eclampsia is a serious hypertensive condition of pregnancy associated with high maternal and fetal morbidity and mortality. Women who have had pre-eclampsia have a greater risk of developing hypertension, stroke and ischemic heart disease in later life. The etiology of pre-eclampsia remains unclear. Placental insufficiency plays a key role in the progression of this disease. The aim of this study was to determine membrane potential, serum calcium and serum selenium levels in preeclampsia subjects in Owerri.   Methods A case control study involving 200 primigravida (100 preeclamptic and 100 apparently healthy between the ages of 20 and 32 years attending General Hospital Owerri. Fasting venous blood was collected for the determination of serum selenium and serum calcium while membrane potential was calculated using the Nernst equation. The serum calcium was estimated using Randox Kit and serum selenium by atomic absorption spectrophotometry. The Independent Student t test was used for statistical analysis.   Results The results revealed that membrane potential and serum selenium as well as serum calcium were significantly decreased in preeclampsia when compared with the controls, at p<0.05.   Conclusion Our study demonstrated that the decrease in membrane potential, serum calcium and serum selenium levels may play a critical role in the pathogenesis of pre-eclampsia. There may be a need for increasing the dietary intake of these essential trace metals during pregnancy to prevent pre-eclampsia in Owerri.

  15. Rapid serum agglutination and agar gel immunodiffusion tests associated to clinical signs in rams experimentally infected with Brucella ovis Teste de soro aglutinação rápida e do teste de imunodifusão em gel de ágar associados aos sinais clínicos em carneiros infectados experimentalmente com Brucella ovis

    Directory of Open Access Journals (Sweden)

    Cristiane Nakada Nozaki

    2011-08-01

    Full Text Available The purpose of this study was to evaluate the agar gel immunodiffusion and the rapid serum agglutination tests associated to clinical signs in rams experimentally infected with Brucella ovis. The serological profile during the 12 months of infection showed a large fluctuation of antibodies that favors the failure in the diagnostic. The evaluation of tests after the experimental infection allowed to suggest that none of the tests were able to detect the infection throughout the period of study. The study reinforces the importance of considering the clinical signs to support the diagnosis of Brucella ovis infection in rams.O objetivo deste estudo foi avaliar o uso do teste de imunodifusão em gel de ágar e o teste sorológico de aglutinação rápida comparados aos sinais clínicos em carneiros infectados experimentalmente com Brucella ovis para o diagnóstico confirmatório da brucelose ovina. O perfil sorológico durante os 12 meses pós-infecção mostrou flutuação da resposta por anticorpos, que favorece a falha no diagnóstico. A avaliação dos testes indicou que nenhum dos testes foi capaz de detectar a infecção durante todo o período de estudo. O estudo ressalta a importância de considerar os sinais clínicos para apoiar o diagnóstico confirmatório da infecção por Brucella ovis em carneiros.

  16. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  17. Evaluating Diagnostic Value of Electrophysiological Testing (EMG-NCV Compared to the Activity Level of Acetylcholinesterase in Serum and Red Blood Cells of Patients with Moderate to Severe Organophosphate Poisoning

    Directory of Open Access Journals (Sweden)

    Fares Najari

    2017-05-01

    Full Text Available Background Organophosphate compounds cause poisoning and death more than any other insecticide. These toxins can cause peripheral neuropathy which is delayed for about 3 - 6 weeks and no method has been known for predicting the incidence. It has been claimed that electrophysiological tests (EMG - NCV can help in predicting the disorder. Objectives The main purpose of this research was to study EMG - NCV tests in patients with moderate to severe organophosphate poisoning. Methods This was a cross-sectional study conducted on patients with moderate to severe organophosphate poisoning from 2014 to 2016 in Imam Reza hospital of Mashhad. The minimum sample size was calculated as 68 patients and then all data was collected on the basis of inclusion and exclusion criteria using data collection form designed by the researcher, and finally data were analyzed using SPSS V.21 software, descriptive tests (including mean, median, mode and analytical tests (K square, ANOVA. Results Of all 78 patients with the mean age of 27.50 ± 10.0, 45 were female and the rest were male. Totally 29.5% of the patients had abnormal EMG - NCV. Although no significant differences were observed between electro diagnostic tests (EMG - NCV and age, gender, clinical symptoms and levels of acetylcholinesterase serum activity, the relationship between EMG - NCV and RBC levels of acetylcholinesterase activity was significant. Conclusions Electrophysiological tests are not associated with clinical symptoms (muscle weakness and they cannot be considered as a determining factor to discharge the patients; therefore, careful examination of the patients or evaluating the level of AChE activity in red blood cells is needed.

  18. Adaptation of a T3-uptake test and of radioimmunoassays for serum digoxin, thyroxine, and triiodothyronine to an automated radioimmunoassay system: ''Centria''

    International Nuclear Information System (INIS)

    Ertingshausen, G.; Shapiro, S.I.; Green, G.; Zborowski, G.

    1975-01-01

    We report the adaptation of four radioassays to the prototype of an automated radioimmunoassay system (''Centria,'' Union Carbide). The system consists of three integrated modules: an automated pipettor, which dispenses samples and reagents; the key module, an incubator/separator, in which centrifugal force is used to initiate and terminate multiple radioassay incubations and separations simultaneously; and a gamma-counter/computer, which counts three tubes simultaneously and converts counts into concentration units. Radioimmunoassays for thyroxine, triiodothyronine, and digoxin were developed with use of well-characterized antibodies and of prepackaged Sephadex-containing columns to separate bound and free radioactive ligand. A triiodothyronine-uptake test in which the same kind of columns were used was also adapted to the instrument. Results for clinical samples compared favorably with those obtained by manual procedures. We report data on correlation between different methods and preliminary data on precision of the prototype system

  19. Enzymes improve ECF bleaching of pulp

    Directory of Open Access Journals (Sweden)

    Lachenal, D.

    2006-07-01

    Full Text Available The delignification efficiency of different laccase enzymes was examined on the eucalyptus Kraft pulp. The laccase enzyme from Trametes versicolor showing the highest delignification efficiency was selected and used in the elemental chlorine-free bleaching sequence for improving the pulp bleachability. An appreciable reduction in chlorine dioxide consumption was also obtained. Further reduction in chlorine dioxide consumption was obtained when the same laccase treated pulp was subjected to an acid treatment after the extraction stage followed by the DEPD sequence. Elemental-chlorine free bleaching was also performed using the xylanase-laccase treated pulp. Xylanase treatment was incorporated to the laccase mediator system in the elemental-chlorine free bleaching both sequentially and simultaneously. The bleaching sequence DEPD followed and in both the cases, the reduction in chlorine dioxide consumption was greater in comparison to the control. The chlorine dioxide consumption was reduced further when xylanase-laccase treated pulp was given an additional acid treatment. The final pulp properties of the treated pulps were comparable to the control pulp.

  20. Evaluation of the profile of alopecia areata and the prevalence of thyroid function test abnormalities and serum autoantibodies in Iranian patients

    Directory of Open Access Journals (Sweden)

    Mirpour Sahar

    2005-10-01

    Full Text Available Abstract Background The study aimed at evaluating the prevalence of thyroid function abnormalities in patients with alopecia areata (AA and its association with other autoimmune diseases and various autoimmune antibodies. Method We retrospectively analyzed medical records of 123 patients with AA. The main site of involvement, pattern, and extent of alopecia as well as presence of the similar disease in first-degree family members and serologic status of patients were recorded. Results Participating in the study were 57 males and 66 females (6 to 59 years old. In the majority of patients (69.9% the disease was manifested in the first two decades of life. Patients with family members having alopecia were recorded in 24.4%. Thyroid function abnormalities were found in 8.9% of patients. Positive autoimmune antibodies were associated with AA in 51.4% of patients with no significant association between the severity and duration of disease and presence of these antibodies. Conclusion The incidence of positive auto-immune antibodies in Iranian patients is higher than previous reports. Concerning the female:male ratio, thyroid function tests and the prevalence of alopecia in first-degree relatives, our results are compatible with previous data obtained from different ethnic populations. Previous reports documented that a greater severity and longer duration of AA were seen in the early onset forms; however our result are relatively different which could be explained by differences in genetic factors.

  1. Non-invasive liver fibrosis score calculated by combination of virtual touch tissue quantification and serum liver functional tests in chronic hepatitis C patients.

    Science.gov (United States)

    Takaki, Shintaro; Kawakami, Yoshiiku; Miyaki, Daisuke; Nakahara, Takashi; Naeshiro, Noriaki; Murakami, Eisuke; Tanaka, Mio; Honda, Yohji; Yokoyama, Satoe; Nagaoki, Yuko; Kawaoka, Tomokazu; Hiramatsu, Akira; Tsuge, Masataka; Hiraga, Nobuhiko; Imamura, Michio; Hyogo, Hideyuki; Aikata, Hiroshi; Takahashi, Shoichi; Arihiro, Koji; Chayama, Kazuaki

    2014-03-01

    Acoustic radiation force impulse (ARFI) technology, involving the shear wave velocity (SWV) with virtual touch tissue quantification (VTTQ), are currently available for the assessment of liver fibrosis, while there is no index derived from the combination of SWV and blood tests. The aim of this study was to develop a new index for assessment of liver fibrosis. The subjects were 176 consecutive patients with hepatitis C (training set [n = 120] and validation set [n = 56]) who underwent liver biopsy in our institution. In the training set, SWV, international normalized ratio (INR) and alanine aminotransferase (ALT) correlated independently and significantly with fibrosis. According to this, we developed the VIA index = -1.282 + 0.965 × SWV + 1.785 INR + 0.00185 ALT. The areas under the receiver-operator curve (AUROC) of the VIA index were 0.838 for the diagnosis of significant fibrosis (≥F2), 0.904 for the severe fibrosis (≥F3) and 0.958 for the cirrhosis (F4) in the training set. While in the validation set, AUROC of the VIA index were 0.917 for F2 or higher, 0.906 for F3 or higher and 1.000 for F4, respectively. AUROC of the VIA index was improved compared to SWV alone, equivalent for VIA for the diagnosis of F2 or higher, and superior to that of FIB-4 index and aspartate aminotransferase-to-platelet ratio index for the diagnosis of F3 or higher and F4. The VIA index is potentially more useful for assessment of liver fibrosis than SWV alone, and easily and accurately measures liver fibrosis stage. © 2013 The Japan Society of Hepatology.

  2. Thyroxine (T4) Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Thryoxine, Serum 485 p. Lab Tests ...

  3. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  4. Disagreement between the results from three commercial tests for the detection of Borrelia-specific serum antibodies in the Netherlands associated with antibiotic treatment for Lyme borreliosis: a retrospective study.

    Science.gov (United States)

    van Gorkom, T; Kremer, K; Voet, W; Notermans, D W; Vlaminckx, B J M; Sankatsing, S U C; Thijsen, S F T

    2017-11-01

    The diagnosis of Lyme borreliosis is challenging because of the often non-specific symptoms and persisting antibodies after infection. We investigated the diagnostic characteristics of two enzyme-linked immunosorbent assays (ELISAs) and an immunoblot for the detection of Borrelia-specific serum antibodies using different test strategies in individuals with and without antibiotic treatment for Lyme borreliosis. This retrospective study included healthy individuals, patients with active Lyme neuroborreliosis and patients treated for Lyme neuroborreliosis. Two ELISAs were compared: the C6 ELISA and the SERION ELISA. Equivocal and positive results were confirmed by immunoblot. We included 174 healthy individuals, of whom 27 (15.5%) were treated for Lyme borreliosis in the past, 36 patients were treated for Lyme neuroborreliosis and 27 patients had active Lyme neuroborreliosis. All the active Lyme neuroborreliosis patients were reactive in both ELISAs (100% sensitivity); less reactivity was seen in the other three groups (range 17.7% to 69.4%). The concordance between the ELISA results was high in active Lyme neuroborreliosis patients (26/27; 96.3%) and healthy individuals (131/147; 89.1%), but lower in treated healthy individuals (18/27; 66.7%) and treated Lyme neuroborreliosis patients (18/36; 50.0%) (p ≤ 0.005). This study showed that antibiotic treatment against Lyme borreliosis was strongly associated with discordant ELISA and test strategy results (odds ratio: 10.52; p Lyme serology.

  5. Comparação de kits ELISA® comerciais para anticorpos no soro e leite com um teste coproparasitológico em bovinos naturalmente infectados por Fasciola hepatica Comparison of comercial® ELISA kits for antibodies in serum and milk with a fecal test in cattle naturally infected with Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Cíntia das C. Bernardo

    2013-01-01

    Full Text Available A fasciolose é uma enfermidade causada por um trematoda que acomete o fígado principalmente de ruminantes domésticos, podendo parasitar o homem e seu diagnóstico é realizado rotineiramente por exames coproparasitológicos. O objetivo do presente estudo foi comparar kits comerciais de ELISA para anticorpos no soro e leite com um teste coproprarasitológico em bovinos naturalmente infectados por Fasciola hepatica. Foram coletadas amostras de fezes (92 sangue (92 e leite (43 de bovinos provenientes de propriedades de gado leiteiro do município de Jerônimo Monteiro, sul do Estado do Espírito Santo. As amostras de fezes coletadas foram processadas pela técnica de sedimentação fecal para ovos de F. hepatica, utilizada como padrão ouro para as análises. Amostras de sangue e de leite foram processadas segundo a orientação do fabricante dos respectivos Kits ELISA comerciais testados. Utilizou-se o c² de McNemar para comparação estatística e calcularam-se a sensibilidade e especificidade, valores preditivos e kappa. Os resultados obtidos mostraram que as frequências de positividade pelo uso dos kits ELISA comerciais de soro e de leite diferiram significativamente (pThe fascioliasis is a disease caused by a trematode that affects the liver mainly of domestic ruminants and can also parasite man; its diagnosis is routinely done by coprological methods. The aim of this study was to compare commercial ELISA kits for antibodies in serum and milk with a coprological test in cattle naturally infected by Fasciola hepatica. We collected fecal, blood and milk samples from cattle in the municipality of Jerônimo Monteiro, southern Espírito Santo state. The fecal samples were processed by the fecal egg sedimentation for F. hepatica, which is used as a gold standard for analyzis. Blood (92 and milk (43 samples were processed according to the manufacturer instructions of the respective commercial ELISA kits tested. We used the McNemar chi-square for

  6. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  7. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  8. Birth order modifies the effect of IL13 gene polymorphisms on serum IgE at age 10 and skin prick test at ages 4, 10 and 18: a prospective birth cohort study

    Science.gov (United States)

    2010-01-01

    Background Susceptibility to atopy originates from effects of the environment on genes. Birth order has been identified as a risk factor for atopy and evidence for some candidate genes has been accumulated; however no study has yet assessed a birth order-gene interaction. Objective To investigate the interaction of IL13 polymorphisms with birth order on allergic sensitization at ages 4, 10 and 18 years. Methods Mother-infant dyads were recruited antenatally and followed prospectively to age 18 years. Questionnaire data (at birth, age 4, 10, 18); skin prick test (SPT) at ages 4, 10, 18; total serum IgE and specific inhalant screen at age 10; and genotyping for IL13 were collected. Three SNPs were selected from IL13: rs20541 (exon 4, nonsynonymous SNP), rs1800925 (promoter region) and rs2066960 (intron 1). Analysis included multivariable log-linear regression analyses using repeated measurements to estimate prevalence ratios (PRs). Results Of the 1456 participants, birth order information was available for 83.2% (1212/1456); SPT was performed on 67.4% at age 4, 71.2% at age 10 and 58.0% at age 18. The prevalence of atopy (sensitization to one or more food or aeroallergens) increased from 19.7% at age 4, to 26.7% at 10 and 41.1% at age 18. Repeated measurement analysis indicated interaction between rs20541 and birth order on SPT. The stratified analyses demonstrated that the effect of IL13 on SPT was restricted only to first-born children (p = 0.007; adjusted PR = 1.35; 95%CI = 1.09, 1.69). Similar findings were noted for firstborns regarding elevated total serum IgE at age 10 (p = 0.007; PR = 1.73; 1.16, 2.57) and specific inhalant screen (p = 0.034; PR = 1.48; 1.03, 2.13). Conclusions This is the first study to show an interaction between birth order and IL13 polymorphisms on allergic sensitization. Future functional genetic research need to determine whether or not birth order is related to altered expression and methylation of the IL13 gene. PMID:20403202

  9. Urticaria crónica: Evolución clínica, prueba del suero autologo, recuento y activación de basofilos Chronic urticaria: Follow up, autologous serum skin test, basophil count and activation

    Directory of Open Access Journals (Sweden)

    N. Galassi

    2003-01-01

    Full Text Available Recientes estudios sugieren que algunos pacientes con urticaria crónica tienen autoanticuerpos dirigidos contra la IgE o a la cadena alfa de su receptor de alta afinidad FceRIa. La detección de éstos se realiza in vivo mediante la prueba del suero autólogo (PSA o in vitro mediante una variedad de técnicas. Describimos aquí nuestra experiencia con 37 pacientes, 28 mujeres y 9 varones con una relación femenino/masculino de 3.1 y edad promedio de 36.5 años (16-78. La PSA fue positiva en 25 (68% y negativa en 12 (32%. El suero indujo una pápula significativamente más grande que el plasma (122 ± 78 mm² vs 57 ± 66 mm², pRecent advances on the pathogenesis of chronic urticaria have defined a group of patients with autoantibodies directed to the IgE or to the alpha chain of the Fc high affinity receptor of IgE, FceRIa. These antibodies are detected in vivo through the autologous serum test (AST and in vitro with a variety of techniques. We here describe 37 patients with chronic urticaria, 28 female and 9 male, with a f/m ratio of 3.1. Mean age at onset was 36.5 years (range 16-78. AST was positive in 25 (68% of 37 patients. Serum induced a wheal significantly larger than plasma (122 ± 78 mm² vs 57 ± 66 mm², p<0.05. Median persistence of the chronic urticaria, estimated by Kaplan-Meyer analysis, was 437 days, with no difference between AST(+ and AST(- patients (437 vs. 369, p=0.18. Mean IgE concentration was 157 ± 173 IU/mL, as expected in an unselected population. Basophil count was lower in patients compared with controls (17 ± 12 cel/mL vs. 43 ± 27 cel/mL, p< 0.008. Only sera from 2/7(28.6% patients AST (+ and very low basophil count consistently induced expression of CD63. This effect was abrogated in non-releasing basophils, confirming the presence of antibodies directed to the FceRIa-IgE . We conclude that functional antibodies are present in only a minority of patients and that their identification does not predict the outcome.

  10. Birth order modifies the effect of IL13 gene polymorphisms on serum IgE at age 10 and skin prick test at ages 4, 10 and 18: a prospective birth cohort study

    Directory of Open Access Journals (Sweden)

    Ogbuanu Ikechukwu U

    2010-04-01

    Full Text Available Abstract Background Susceptibility to atopy originates from effects of the environment on genes. Birth order has been identified as a risk factor for atopy and evidence for some candidate genes has been accumulated; however no study has yet assessed a birth order-gene interaction. Objective To investigate the interaction of IL13 polymorphisms with birth order on allergic sensitization at ages 4, 10 and 18 years. Methods Mother-infant dyads were recruited antenatally and followed prospectively to age 18 years. Questionnaire data (at birth, age 4, 10, 18; skin prick test (SPT at ages 4, 10, 18; total serum IgE and specific inhalant screen at age 10; and genotyping for IL13 were collected. Three SNPs were selected from IL13: rs20541 (exon 4, nonsynonymous SNP, rs1800925 (promoter region and rs2066960 (intron 1. Analysis included multivariable log-linear regression analyses using repeated measurements to estimate prevalence ratios (PRs. Results Of the 1456 participants, birth order information was available for 83.2% (1212/1456; SPT was performed on 67.4% at age 4, 71.2% at age 10 and 58.0% at age 18. The prevalence of atopy (sensitization to one or more food or aeroallergens increased from 19.7% at age 4, to 26.7% at 10 and 41.1% at age 18. Repeated measurement analysis indicated interaction between rs20541 and birth order on SPT. The stratified analyses demonstrated that the effect of IL13 on SPT was restricted only to first-born children (p = 0.007; adjusted PR = 1.35; 95%CI = 1.09, 1.69. Similar findings were noted for firstborns regarding elevated total serum IgE at age 10 (p = 0.007; PR = 1.73; 1.16, 2.57 and specific inhalant screen (p = 0.034; PR = 1.48; 1.03, 2.13. Conclusions This is the first study to show an interaction between birth order and IL13 polymorphisms on allergic sensitization. Future functional genetic research need to determine whether or not birth order is related to altered expression and methylation of the IL13 gene.

  11. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  12. Serum concentrations of mast cell tryptase are reduced in heavy drinkers

    DEFF Research Database (Denmark)

    Beceiro, Carmen; Campos, Joaquín; Valcarcel, Maria-Angeles

    2015-01-01

    BACKGROUND: Baseline serum tryptase concentrations are commonly used in clinical practice as a marker of the body's mast cell burden. This study aimed to investigate serum tryptase concentrations in heavy drinkers. METHODS: Serum tryptase concentrations were determined in 126 heavy drinkers (75...... test positivity) was not associated with serum tryptase concentrations in heavy drinkers. CONCLUSIONS: Serum concentrations of mast cell tryptase are lower in heavy drinkers than in healthy controls....

  13. Radioimmunological determination of digoxin in serum

    International Nuclear Information System (INIS)

    Gruber, G.; Sorger, D.

    1979-01-01

    The tested quality signs of the digoxin-RIA (Medica) correspond to other RIA-test methods. The digoxin-RIA (Medica) is, therefore, well suited for clinical examinations. In the dilanacin-(digoxin-) long-term therapy with the maintenance dose of 0.5 mg digoxin a day 75.4% of the patients examined (n = 65) were within the therapeutic field. In each case 12.3% were underdigitalised or overdigitalised, respectively. In the 8 patients in the toxic region only the half showed signs of digoxin intoxication. It is referred to the importance of creatinine and potassium in the serum, to the digoxin creatinene and potassium in the serum, to the digoxin clearance depending on age, to the body weight and the body surface, respectively, in very obese patients for the height of the serum digoxin level and for the compatibility of this heart glycoside. (author)

  14. Myoglobin blood test

    Science.gov (United States)

    Serum myoglobin; Heart attack - myoglobin blood test; Myositis - myoglobin blood test; Rhabdomyolysis - myoglobin blood test ... too high, it can damage the kidneys. This test is ordered when your health care provider suspects ...

  15. Racial difference in serum Vitamin B12 levels

    International Nuclear Information System (INIS)

    Kwee, H.G.; Bowman, H.S.; Wells, L.W.

    1985-01-01

    Measurements of the serum Vitamin B 12 concentrations of 49 black and 49 white healthy adults demonstrate a significantly higher mean serum Vitamin B 12 level in blacks when compared to whites. The reason for this difference appears to be genetic, although environmental factors may also be involved. It is suggested that clinical laboratories should establish their own separate reference values of serum Vitamin B 12 for blacks and whites in order to prevent misinterpretation of test results

  16. Serum YKL-40

    DEFF Research Database (Denmark)

    Mylin, Anne K; Abildgaard, Niels; Johansen, Julia S

    2015-01-01

    to clinical progression, i.e. skeletal-related events (SREs), in 230 newly diagnosed patients with multiple myeloma receiving intravenous bisphosphonates. Serum concentrations of YKL-40 and biochemical bone markers (CTX-MMP, CTX-I, PINP) were measured at diagnosis. Patients were evaluated every third month...

  17. 79 - 81_Wali - Serum

    African Journals Online (AJOL)

    DR. AMINU

    2013-06-01

    Jun 1, 2013 ... SERUM ANTIOXIDANT VITAMINS LEVELS IN CHILDREN WITH SICKLE. CELL ANAEMIA IN ... play a role in the development of sickle cell anaemic complications. In the current study, ... vaso-occlusive episodes, acute chest syndrome and impaired ... frequency of sickling crises accompanied by tissue or.

  18. VDRL test

    Science.gov (United States)

    ... confirmed with another blood test to make the diagnosis of syphilis. Normal value ranges may vary slightly among different ... broken) Alternative Names Venereal disease research ... laboratory test (VDRL) – serum. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; ...

  19. Effects of intramuscular administration of tiletamine-zolazepam with and without sedative pretreatment on plasma and serum biochemical values and glucose tolerance test results in Japanese black bears (Ursus thibetanus japonicus).

    Science.gov (United States)

    Kamine, Akari; Shimozuru, Michito; Shibata, Haruki; Tsubota, Toshio

    2012-08-01

    To establish a safe anesthetic protocol with little effect on blood biochemical values and IV glucose tolerance test (IVGTT) results in Japanese black bears (Ursus thibetanus japonicus). 16 captive female Japanese black bears (5 to 17 years of age). Bears were randomly assigned to 4 treatment groups (4 bears/group) in which various treatment combinations were administered via blow dart: tiletamine HCl and zolazepam HCl (9 mg/kg) alone (TZ), TZ (6 mg/kg) and acepromazine maleate (0.1 mg/kg), TZ (6 mg/kg) and butorphanol tartrate (0.3 mg/kg), or TZ (3 mg/kg) and medetomidine HCl (40 μg/kg). Glucose injection for the IVGTT was started 130 minutes after TZ administration. Blood samples were obtained before, at, and intermittently after glucose injection for measurement of biochemical variables as well as plasma glucose and serum insulin concentrations during the IVGTT. Rectal temperature, pulse rate, and respiratory rate were assessed every 15 minutes during the experiment. Induction and maintenance of anesthesia were safely achieved with little adverse effect on cardiopulmonary function when each of the 4 anesthetic regimens was used, although mild hypothermia was induced. No difference was evident between treatment groups in blood biochemical values. Blood glucose and insulin concentration profiles during the IVGTT were similar among the bears given TZ, with or without acepromazine or butorphanol, but hyperglycemia and hypoinsulinemia developed in bears given TZ with medetomidine. All 4 anesthetic regimens yielded chemical restraint without affecting clinical and biochemical values in bears, but medetomidine appeared to affect IVGTT results. For this reason, medetomidine should not be used when anesthetizing bears for IVGTTs.

  20. The relative role of serum albumin and urinary creatinine as ...

    African Journals Online (AJOL)

    Their weight, Body mass index, serum albumin and 24-hour urinary creatinine were determined before treatment, at the end of the 1st, 2nd, 4th and 6th month of treatment. Using ANOVA, the mean values of the weight, BIM and serum albumin were analysed with further analysis paired student T- test of the pre-treatment ...

  1. Sucrose/bovine serum albumin mediated biomimetic crystallization

    Indian Academy of Sciences (India)

    To understand the role of the sucrose/bovine serum albumin system in the biomineralization process, we have tested the influence of different concentration of the sucrose/bovine serum albumin (BSA) on calcium carbonate (CaCO3) precipitation. The CaCO3 crystals were characterized by scanning electron microscope ...

  2. A low percentage of autologous serum can replace bovine serum to engineer human nasal cartilage

    Directory of Open Access Journals (Sweden)

    F Wolf

    2008-02-01

    Full Text Available For the generation of cell-based therapeutic products, it would be preferable to avoid the use of animal-derived components. Our study thus aimed at investigating the possibility to replace foetal bovine serum (FBS with autologous serum (AS for the engineering of cartilage grafts using expanded human nasal chondrocytes (HNC. HNC isolated from 7 donors were expanded in medium containing 10% FBS or AS at different concentrations (2%, 5% and 10% and cultured in pellets using serum-free medium or in Hyaff®-11 meshes using medium containing FBS or AS. Tissue forming capacity was assessed histologically (Safranin O, immunohistochemically (type II collagen and biochemically (glycosaminoglycans -GAG- and DNA. Differences among experimental groups were assessed by Mann Whitney tests. HNC expanded under the different serum conditions proliferated at comparable rates and generated cartilaginous pellets with similar histological appearance and amounts of GAG. Tissues generated by HNC from different donors cultured in Hyaff®-11 had variable quality, but the accumulated GAG amounts were comparable among the different serum conditions. Staining intensity for collagen type II was consistent with GAG deposition. Among the different serum conditions tested, the use of 2% AS resulted in the lowest variability in the GAG contents of generated tissues. In conclusion, a low percentage of AS can replace FBS both during the expansion and differentiation of HNC and reduce the variability in the quality of the resulting engineered cartilage tissues.

  3. Serum Creatinine: Not So Simple!

    OpenAIRE

    DELANAYE, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDM...

  4. Serum triiodothyronine and free triiodothyronine index in normal pregnancy

    International Nuclear Information System (INIS)

    Karunanidhi, A.; Charles, S.X.; Kanagasabapathy, A.S.

    1981-01-01

    The thyroid function at various stages of pregnancy and after delivery was assessed by measuring serum total triiodothyronine (T 3 ), T 3 resin uptake (T 3 RU) and free triiodothyronine index (FT 3 I). In first, second and third trimesters of pregnancy, the mean values of serum total T 3 were significantly elevated (P 3 I remained unaltered. During labour, both serum total T 3 and FT 3 I observed during labour and after delivery may be due to the changes in blood oestrogen levels. This study indicates that serum free T 3 concentrations in pregnancy remained unaltered in the presence of elevated serum total T 3 levels. FT 3 I determination would thus appear to be a reliable in vitro thyroid function test for the assessment of thyroid function throughout pregnancy. Serum total T 3 was measured by radioimmunoassay using radioiodinated T 3 ( 125 I-T 3 ). (author)

  5. The Human Serum Metabolome

    Science.gov (United States)

    Psychogios, Nikolaos; Hau, David D.; Peng, Jun; Guo, An Chi; Mandal, Rupasri; Bouatra, Souhaila; Sinelnikov, Igor; Krishnamurthy, Ramanarayan; Eisner, Roman; Gautam, Bijaya; Young, Nelson; Xia, Jianguo; Knox, Craig; Dong, Edison; Huang, Paul; Hollander, Zsuzsanna; Pedersen, Theresa L.; Smith, Steven R.; Bamforth, Fiona; Greiner, Russ; McManus, Bruce; Newman, John W.; Goodfriend, Theodore; Wishart, David S.

    2011-01-01

    Continuing improvements in analytical technology along with an increased interest in performing comprehensive, quantitative metabolic profiling, is leading to increased interest pressures within the metabolomics community to develop centralized metabolite reference resources for certain clinically important biofluids, such as cerebrospinal fluid, urine and blood. As part of an ongoing effort to systematically characterize the human metabolome through the Human Metabolome Project, we have undertaken the task of characterizing the human serum metabolome. In doing so, we have combined targeted and non-targeted NMR, GC-MS and LC-MS methods with computer-aided literature mining to identify and quantify a comprehensive, if not absolutely complete, set of metabolites commonly detected and quantified (with today's technology) in the human serum metabolome. Our use of multiple metabolomics platforms and technologies allowed us to substantially enhance the level of metabolome coverage while critically assessing the relative strengths and weaknesses of these platforms or technologies. Tables containing the complete set of 4229 confirmed and highly probable human serum compounds, their concentrations, related literature references and links to their known disease associations are freely available at http://www.serummetabolome.ca. PMID:21359215

  6. Calcium in Urine Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  7. Radioimmunoassay for erytropoetin serum level in polycythemia

    International Nuclear Information System (INIS)

    Nikolova, K.; Vassileva, D.

    2003-01-01

    Erythropoietin (Epo) is the first well studied hemopoietic growth factor. The pathological levels of its serum concentration show deviations in the specific mechanisms for some diseases such as polycythemia. Objective of this work is the assessment of the diagnostic value of the Epo in the serum for the differentiation of the main form of polycythemia - true and symptomatic. Material and methods: 47 patients are studied (21 women and 26 men), 23 of them are with polycythemia vera and 24 with polycythemia symptomatica. The following has been determined: the serum level of Erythropoietin, hemoglobin, the number of erythrocytes, leukocytes, thrombocytes, myelogram. The serum level of Epo is quantitatively determined b using of radioimmunological method, through Epo-Trac kit. Results: The diagnosis is also confirmed in all patients by other laboratory tests. The normal values of Epo in healthy persons are 17.0±7.0 mU/ml. The average Epo level in patients with polycythemia vera is 20.4±3.0 mU/ml. In one patient the Epo level is supposedly connected with an accompanying kidney disease. Conclusions: The obtained data show that the Epo serum level is an accurate criterion in the diagnosing of true and symptomatic polycythemia. The true polycythemia is connected with an independent erythrocyte production. In the symptomatic polycythemia the tissue hypoxia stimulated the Epo production

  8. Ferritin Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Ferritin, Serum; 296 p. Lab Tests ...

  9. Evaluation of the VeriStrat® serum protein test in patients with advanced squamous cell carcinoma of the lung treated with second-line afatinib or erlotinib in the phase III LUX-Lung 8 study.

    Science.gov (United States)

    Gadgeel, Shirish; Goss, Glenwood; Soria, Jean-Charles; Felip, Enriqueta; Georgoulias, Vassilis; Lu, Shun; Cobo, Manuel; Syrigos, Konstantinos; Lee, Ki Hyeong; Göker, Erdem; Guclu, Salih Z; Isla, Dolores; Morabito, Alessandro; Dupuis, Nicholas; Bühnemann, Claudia; Krämer, Nicole; Solca, Flavio; Ehrnrooth, Eva; Ardizzoni, Andrea

    2017-07-01

    Identification of biomarkers associated with clinical benefit may be crucial in establishing optimal treatment choice for patients with squamous cell carcinoma (SCC) of the lung after first-line chemotherapy. In this study, the ability of the VeriStrat serum protein test to predict differential clinical benefit with afatinib versus erlotinib, and the association of VeriStrat status with clinical outcomes irrespective of EGFR-TKI used, was assessed in a retrospective analysis of the phase III LUX-Lung 8 trial. Pretreatment plasma samples were analyzed using matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Spectra were evaluated to assign a VeriStrat 'Good' (VS-G) or VeriStrat 'Poor' (VS-P) classification. Overall survival (OS), progression-free survival, and other endpoints were assessed with respect to pretreatment VeriStrat status; OS was the primary efficacy variable. Outcomes with other efficacy endpoints were similar. Of 795 patients randomized in LUX-Lung 8, 675 were classified (VS-G: 412; VS-P: 263). In the VS-G group, OS was significantly longer with afatinib versus erlotinib (HR 0.79 [95% CI: 0.63-0.98]). In the VS-P group, there was no significant difference in OS between afatinib and erlotinib (HR 0.90 [0.70-1.16]). However, there was no interaction between VeriStrat classification and treatment group for OS (p interaction =0.5303). OS was significantly longer in VS-G versus VS-P patients, both in the overall VeriStrat-classified population (HR 0.41 [0.35-0.49]) and afatinib-treated patients (HR 0.40 [0.31-0.51]). Multivariate analysis showed that VeriStrat was an independent predictor of OS in afatinib-treated patients, regardless of ECOG PS or best response to first-line chemotherapy. VS-G classification is strongly associated with favorable survival outcomes with either afatinib or erlotinib compared with VS-P classification. In VS-G patients, survival outcomes with afatinib are superior to those with erlotinib. Veri

  10. Disagreement between the results from three commercial tests for the detection of Borrelia-specific serum antibodies in the Netherlands associated with antibiotic treatment for Lyme borreliosis: a retrospective study.

    NARCIS (Netherlands)

    van Gorkom, T; Kremer, K; Voet, W; Notermans, D W; Vlaminckx, B J M; Sankatsing, S U C; Thijsen, S F T

    2017-01-01

    The diagnosis of Lyme borreliosis is challenging because of the often non-specific symptoms and persisting antibodies after infection. We investigated the diagnostic characteristics of two enzyme-linked immunosorbent assays (ELISAs) and an immunoblot for the detection of Borrelia-specific serum

  11. Prevalence of antileptospiral serum antibodies in dogs in Ireland

    Science.gov (United States)

    A total of 474 serum samples from client owned Irish dogs were tested for the presence of antibodies against serovars Canicola, Icterohaemorrhagiae, Bratislava, Autumnalis, Pomona, Altodouro, Grippotyphosa, Mozdok, Hardjobovis and Ballum. Six percent of dogs presented to veterinary practitioners for...

  12. Functional assay of the alternative complement pathway of rat serum

    International Nuclear Information System (INIS)

    Coonrod, J.D.; Jenkins, S.D.

    1979-01-01

    Two functional assays of the alternative pathway of complement activation in rat serum were developed. In the first assay, conditions were established for titration of alternative pathway activity by use of the 50% hemolytic end-point of rabbit red blood cells (RaRBC) in serum treated with ethyleneglycol-bis-(beta-aminoethyl ether)-N, N'-tetraacetic acid (EGTA). The second assay of alternative pathway activity was based on the opsonization of heat-killed radiolabeled pneumococci of serotype 25 (Pn25). Opsonization of Pn25 was shown to proceed entirely via the alternative pathway in rat serum. There was excellent correlation between the results obtained with the RaRBC lysis test and those obtained with the opsonization test. Because of its technical simplicity, the RaRBC lysis test appeared to be the single most useful test of alternative pathway activity in rat serum. (Auth.)

  13. Study of serum copper and ceruloplasmin levels in Egyptian autistic ...

    African Journals Online (AJOL)

    Farida El-Baz

    2018-02-15

    Feb 15, 2018 ... examination, IQ assessment, estimation of serum copper and ceruloplasmin levels. Results: A statistically ... April 2012. The control group ... Mental age рMAЮ assessed using the proper test ..... In: Reynolds CR, Kamphaus.

  14. Depression and BMI influences the serum vascular endothelial growth factor level

    DEFF Research Database (Denmark)

    Elfving, Betina; Buttenschøn, Henriette Nørmølle; Foldager, Leslie

    2014-01-01

    in serum by immunoassay and independent determinants of the serum VEGF level were assessed by generalized linear models.The main findings were that depression, severity of depression, previous depressive episodes, age and body mass index (BMI) were associated with higher serum VEGF levels. The genetic...... marker rs10434 was significantly associated with depression after correction for multiple testing, but not with the serum VEGF level. Our final model included depression and BMI as predictors of serum VEGF levels. Our study suggests a role for circulating serum VEGF in depression. Furthermore, our data...

  15. Serum neurotrophin concentrations in polish adolescent girls with anorexia nervosa.

    Science.gov (United States)

    Dmitrzak-Weglarz, Monika; Skibinska, Maria; Slopien, Agnieszka; Tyszkiewicz, Marta; Pawlak, Joanna; Maciukiewicz, Małgorzata; Zaremba, Dorota; Rajewski, Andrzej; Hauser, Joanna

    2013-01-01

    Several lines of evidence suggest that brain-derived neurotrophic factor (BDNF) plays an important role in weight regulation and eating behaviors as well as in the activity-dependent neuroplasticity underlying learning and memory behaviors involving the hippocampus. In anorexia nervosa (AN) patients, abnormal serum BDNF concentrations, cognitive impairments and specific personality traits have been traditionally observed. This study explores the levels of four serum neurotrophins [BDNF, neurotrophin 3 (NTF3), neurotrophin 4 (NTF4) and glial cell line-derived neurotrophic factor (GDNF)] with respect to their use as potential biomarkers for AN. This study also investigates any associations that might exist between serum neurotrophin levels and neurocognitive impairment or personality traits. Serum neurotrophin concentrations were measured in 60 AN patients (AN group) and 45 healthy controls (HC group). We correlated the serum levels of the four neurotrophins BDNF, NTF3, NTF4 and GDNF and the clinical type of anorexia. We also analyzed the relationship between serum neurotrophin levels and the Beck Depression Inventory, body mass index, executive functions by the Wisconsin Card Sorting test (WCST) and personality dimensions by the Temperament and Character Inventory (TCI) test. Serum NTF4 concentrations were significantly lower when comparing all AN patients (34.7 ± 72.5 pg/ml) or restriction type AN patients (29.1 ± 62.5 pg/ml) with the HC group (58.4 ± 135.8 pg/ml; p = 0.004 and p = 0.005, respectively). A significant correlation (p < 0.005) between BDNF serum levels and patient personality dimensions as measured by the TCI test was observed. Furthermore, significant correlations were observed between NTF4 and GDNF serum levels and executive function as measured by the WCST. These data suggest that NTF4 might serve as a biomarker for AN. Furthermore, BDNF and GDNF serum levels appear to be associated with personality traits and executive function. Copyright

  16. Serum Creatinine: Not So Simple!

    Science.gov (United States)

    Delanaye, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). © 2017 S. Karger AG, Basel.

  17. A Comparative Assessment of Serum Vitamin C and Serum Lead Among Periodontitis and Diabetic Patient

    Directory of Open Access Journals (Sweden)

    Shetty Akshatha

    2017-09-01

    Full Text Available Background and Aims: Pre and post-operative nutritional status are not often tested on a consistent basis when patients are analyzed and diagnosed with Type 2 Diabetes Mellitus (T2DM or have chronic periodontitis. Thus, this study pursues to evaluate the predictive value of serum vitamin C and lead levels in this population at baseline and after periodontal treatment.

  18. Relationship between serum total magnesium and serum potassium ...

    African Journals Online (AJOL)

    Relationship between serum total magnesium and serum potassium in emergency surgical patients in a tertiary hospital in Ghana. Robert Djagbletey, Brenda Phillips, Frank Boni, Christian Owoo, Ebenezer Owusu-Darkwa, Papa Kobina Gyakye deGraft-Johnson, Alfred E. Yawson ...

  19. Serum Metabonomics of Mild Acute Pancreatitis.

    Science.gov (United States)

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  20. Serum Free Light Chains

    Science.gov (United States)

    ... lab's website in order to provide you with background information about the test(s) you had performed. You will need to return ... the free light chains have a much shorter half-life (3-5 hours) than ... cell disorders, the test is also used for assessing response and minimal ...

  1. Serum ferritin, serum nitric oxide, and cognitive function in pediatric thalassemia major

    Directory of Open Access Journals (Sweden)

    Septiana Nur Qurbani

    2017-06-01

    Full Text Available Background Hemolysis and repeated blood transfusions in children with thalassemia major cause iron overload in various organs, including the brain, and may lead to neurodegeneration. Hemolysis also causes decreased levels of nitric oxide, which serves as a volume transmitter and slow dynamic modulation, leading to cognitive impairment. Objective To assess for correlations between serum ferritin as well as nitric oxide levels and cognitive function in children with thalassemia major.  Methods This analytical study with cross-sectional design on 40 hemosiderotic thalassemia major patients aged 6−14 years, was done at the Thalassemia Clinic in Dr. Hasan Sadikin Hospital, Bandung, West Java, from May to June 2015. Serum ferritin measurements were performed by an electrochemiluminescence immunoassay; serum nitric oxide was assayed by a colorimetric procedure based on Griess reaction; and cognitive function was assessed by the Wechsler Intelligence Scale for Children test. Statistical analysis was done using Spearman’s Rank correlation, with a significance value of 0.05. Results Abnormal values in verbal, performance, and full scale IQ were found in 35%, 57.5% and 57.5%, respectively. Serum nitric oxide level was significantly correlated with performance IQ (P=0.022, but not with verbal IQ (P=0.359 or full scale IQ (P=0.164. There were also no significant correlations between serum ferritin level and full scale, verbal, or performance IQ (P=0.377, 0.460, and 0.822, respectively. Conclusion Lower serum nitric oxide level is significantly correlated to lower cognitive function, specifically in the performance IQ category. However, serum ferritin level has no clear correlation with cognitive function.

  2. Serum amyloid A and haptoglobin concentrations in serum and peritoneal fluid of healthy horses and horses with acute abdominal pain

    DEFF Research Database (Denmark)

    Pihl, Tina Holberg; Andersen, Pia Haubro; Kjelgaard-Hansen, Mads

    2013-01-01

    BACKGROUND: Peritoneal fluid (PF) analysis is a valuable diagnostic tool in equine medicine. Markers such as serum amyloid A (SAA) and haptoglobin (Hp) could facilitate the diagnosis of inflammatory abdominal conditions. OBJECTIVES: The objectives were to (1) establish reference intervals (RI......) for SAA and Hp in serum and PF in healthy horses, (2) compare SAA and Hp concentrations between healthy horses and horses with colic, and (3) to assess the correlation between serum and PF concentrations. METHODS: Serum amyloid A and Hp concentrations were determined by automated assays in prospectively...... enrolled healthy reference horses and horses with colic. RIs were calculated, group concentrations were compared by Student's t-test, and Pearson's correlation for serum and PF concentrations were determined. RESULTS: In healthy horses (n = 62) the measurements for SAA were below the detection limit (0...

  3. Serum hyaluronic acid as a marker of hepatic fibrosis

    International Nuclear Information System (INIS)

    Khan, J.A.; Khan, F.A.; Ijaz, A.; Khan, N.A.; Mehmood, T.

    2007-01-01

    To determine the serum hyaluronic acid (HA) levels as biochemical marker of hepatic fibrosis and cirrhosis and correlate it with the degree of hepatic fibrosis and cirrhosis. This study was performed on 100 patients of chronic liver disease whose liver biopsies had been carried out. Fifty healthy controls were also included in the study. Routine liver function tests, hepatitis serology and serum hyaluronic acid levels were carried out on patients and controls. Liver biopsy of 100 patients revealed that 21 were in stage 0 fibrosis, 38 in stage 1 fibrosis, 26 in stage 3 fibrosis and 15 in stage 4 fibrosis. Mean Serum HA (mean +- SD) concentration in patients were 189 +- 98 mg/L vs. 21 +- 10 mg/L of healthy controls. The difference observed was statistically significant (p < 0.001). Patients in stage 4 fibrosis had significantly higher (p <0.001) mean serum HA concentration as compared to other stages of liver fibrosis. Diagnostic accuracy of serum HA at marginally elevated level of 60 mg/L determined the sensitivity 78.4 %, specificity 80.9%, positive predicted value 93.9% and negative predicted value of 50%. Serum HA is a useful non-invasive marker of liver fibrosis. There is a strong positive correlation between serum HA levels and degree of liver fibrosis. The concentration of serum HA rises according to progression of liver fibrosis and levels are highest in patients with liver cirrhosis. (author)

  4. Sodium serum levels in hypoalbuminemic adults at general medical wards

    Directory of Open Access Journals (Sweden)

    Cunha Daniel Ferreira da

    1999-01-01

    Full Text Available Hypoalbuminemia may cause interstitial edema and hemodilution, which we hypothesized may influence serum sodium levels. Our purpose was to compare serum sodium levels of hospitalized adults with or without hypoalbuminemia. All sodium and albumin serum levels of 142 adults hospitalized at general medical wards over a six-month period were searched at a University Hospital mainframe computer. Relevant laboratory data and clinical details were also registered. Hypoalbuminemia was defined by serum albumin concentration < 3.3 g/dl Fisher, Mann-Whitney, and Student's t tests were applied to compare groups with or without hypoalbuminemia. Ninety-nine patients, classified as hypoalbuminemic, had lower blood hemoglobin (10.68 ± 2.62 vs. 13.54 ± 2.41, and sodium (135.1 ± 6.44 vs. 139.9 ± 4.76mEq/l and albumin (2.74 ± 0.35 vs. 3.58 ± 0.28g/dl serum levels than non-hypoalbuminemic (n=43. Pearson's coefficient showed a significant direct correlation between albumin and sodium serum levels (r=0.40 and between serum albumin and blood hemoglobin concentration (r=0.46. Our results suggest that hypoalbuminemic adults have lower serum sodium levels than those without hypoalbuminemia, a phenomenon that may be at least partially attributed to body water retention associated with acute phase response syndrome.

  5. Comparison of serum C3 complement levels between young women ...

    African Journals Online (AJOL)

    Maimun Syukri

    2014-05-29

    May 29, 2014 ... between young women with recurrent urinary tract ... test and Fisher's exact test or t-test as appropriate with data. .... immunosuppressive diseases, use of immunosuppressive drug, ... Serums were removed and stored at А70 °C and used .... Urinary tract infections: new insights into a common problem.

  6. DETERMINATION OF SERUM ALBUMIN WITH ...

    African Journals Online (AJOL)

    The reaction of tribromoarsenazo(TB-ASA) with serum albumin in the presence of emulgent OP was studied by spectrophotometry. In a Britton-Robinson buffer solution at pH 2.9, tribromoarsenazo and bovine serum albumin can immediately form a red compound in the presence of emulgent OP with a maximum absorption ...

  7. Zinc, lead, and cadmium levels in serum and milk of lactating women in Ibadan, Nigeria.

    Science.gov (United States)

    Edem, Victory Fabian; Akintunde, Kikelomo; Adelaja, Yewande Adeola; Nwozo, Sarah O; Charles-Davies, Mabel

    2017-01-01

    Zinc (Zn) is known to interact with lead (Pb) and cadmium (Cd) reversing their toxicity and reducing their concentrations. However, lactating women are at high risk of developing Zn deficiency, which may result in Pb and Cd intoxication or increased exposure of breast-fed infants to Pb and Cd from breast milk. The aim of this study was to determine Zn, Pb, and Cd concentrations and examine their relationship in serum and breast milk of lactating women in Ibadan, Nigeria. Ninety-two lactating women were recruited into this study. Anthropometric measurements were assessed by standard methods while serum and breast milk concentrations of Zn, Pb, and Cd were assessed by atomic absorption spectrophotometry. Data analyzed statistically by Student's t test, Pearson's correlation coefficient, and a multiple regression model were significant at p < 0.05. Zn deficiency was observed in 12 (17.1%) of lactating women. Breast milk levels of Zn, Pb, and Cd were significantly higher than their levels in serum, whereas the ratios Zn:Pb and Zn:Cd in milk were significantly less than serum ratios. Significant negative correlation was observed between milk Pb and serum Zn:Pb while milk Cd correlated positively with milk Zn. Significant positive correlations were observed between serum Zn and serum Zn:Pb, serum Zn and serum Zn:Cd, as well as serum Zn:Cd and serum Zn:Pb. Serum Cd and serum Zn were significantly negatively related. Significant negative correlations between serum Pb and serum Zn:Pb as well as milk Zn:Pb. Serum Cd and serum Zn:Pb as well as serum Zn:Cd correlated negatively. Milk Cd and Zn/Cd positively related with milk Pb while milk Zn was a negatively related with milk Pb in a multiple regression model ( R 2 = 0.333; p = 0.023). Breast milk may be contaminated by toxic metals. However, Zn supplementation in deficient mothers may protect maternal and infant health.

  8. ACE blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003567.htm ACE blood test To use the sharing features on this page, ... Alternative Names Serum angiotensin-converting enzyme; SACE Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  9. Tularemia blood test

    Science.gov (United States)

    Tularemia test; Serology for Francisella tularensis ... This blood test is done when tularemia is suspected. ... Elsevier; 2017:chap 44. Chernecky CC, Berger BJ. Tularemia agglutinins - serum. In: Chernecky CC, Berger BJ, eds. ...

  10. False positive acetaminophen concentrations in icteric serum

    Directory of Open Access Journals (Sweden)

    L. de Jong

    2016-04-01

    Full Text Available Introduction: Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. Description: A 49-year-old woman was admitted to our hospital with a hepatic encephalopathy and a total serum bilirubin concentration of 442 µmol/l. The acetaminophen concentration of 11.5 mg/l was measured with an enzymatic-colorimetric assay, thus treatment with N-acetyl cysteine was started. Interestingly, the acetaminophen concentration remained unchanged (11.5–12.3 mg/l during a period of 4 consecutive days. In contrast, the acetaminophen concentration measured by HPLC, a chromatographic technique, remained undetectable Discussion: In the presented case, elevated bilirubin was the most likely candidate to interfere with acetaminophen assay causing false positive results. Bilirubin has intense absorbance in the ultraviolet and visible regions of the electromagnetic spectrum and for that reason it causes interference in an enzymatic-colorimetric assay. Conclusion: False positive acetaminophen laboratory test results may be found in icteric serum, when enzymatic-colorimetric assays are used for determination of an acetaminophen concentration. Questionable acetaminophen results in icteric serum should be confirmed by a non-enzymatic method, by means of ultrafiltration of the serum, or by dilution studies. Keywords: Acetaminophen, Enzymatic-colorimetric assays, HPLC, Bilirubin, Interference, Paracetamol, Liver failure, Jaundice

  11. Higher Total Serum Cholesterol Levels Are Associated With Less Severe Strokes and Lower All-Cause Mortality

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj; Christensen, Rune Haubo Bojesen; Kammersgaard, Lars

    2007-01-01

    Background and Purpose - Evidence of a causal relation between serum cholesterol and stroke is inconsistent. We investigated the relation between total serum cholesterol and both stroke severity and poststroke mortality to test the hypothesis that hyperch....

  12. Inhibitor of DNA synthesis is present in normal chicken serum

    International Nuclear Information System (INIS)

    Franklin, R.A.; Davila, D.R.; Westly, H.J.; Kelley, K.W.

    1986-01-01

    The authors have found that heat-inactivated serum (57 0 C for 1 hour) from normal chickens reduces the proliferation of mitogen-stimulated chicken and murine splenocytes as well as some transformed mammalian lymphoblastoid cell lines. Greater than a 50% reduction in 3 H-thymidine incorporation was observed when concanavalin A (Con A)-activated chicken splenocytes that were cultured in the presence of 10% autologous or heterologous serum were compared to mitogen-stimulated cells cultured in the absence of serum. Normal chicken serum (10%) also caused greater than 95% suppression of 3 H-thymidine incorporation by bovine (EBL-1 and BL-3) and gibbon ape (MLA 144) transformed lymphoblastoid cell lines. The only cell line tested that was not inhibited by chicken serum was an IL-2-dependent, murine cell line. Chicken serum also inhibited both 3 H-thymidine incorporation and IL-2 synthesis by Con A-activated murine splenocytes. Suppression was caused by actions other than cytotoxicity because viability of chicken splenocytes was unaffected by increasing levels of chicken serum. Furthermore, dialyzed serum retained its activity, which suggested that thymidine in the serum was not inhibiting uptake of radiolabeled thymidine. Suppressive activity was not due to adrenal glucocorticoids circulating in plasma because neither physiologic nor pharmacologic doses of corticosterone had inhibitory effects on mitogen-stimulated chicken splenocytes. These data demonstrate that an endogenous factor that is found in normal chicken serum inhibits proliferation of T-cells from chickens and mice as well as some transformed mammalian lymphoblastoid cell lines

  13. Gamma radiation effects on liofilized human serum

    International Nuclear Information System (INIS)

    Padron Soler, E.; Romay Penabad, Z.; Chavez Ardanza, A.; Hernandez Gonzalez, C.; Martin Gonzalez, O.; Garcia Gonzalez, I.; Prieto Miranda, E.

    1995-01-01

    Human freeze dried serum was artificially contaminated with Flavobacterium sp. for studying the effects of gamma radiation of it. The radiobiological parameters of the contaminator were determined and the sterilization dose was set. The quality of the product irradiated at both, calculated sterilization dose (8.5 kGy) an another one about 25 kGy was determined. It was made according to: sterility testing, total proteins, pH enzymes (alanina-aminotransferase, aspartato-aminotransferase, alkaline phosphatase), protein electrophoresis, fast performance liquid chromatographic and effect on the cellular growth. From the latter was concluded that the calculated sterilization dose was adequate form keeping the biological properties and viability of the irradiated serum. Nevertheless, the dose of 25 k Gy was not adequate because of its dangerous effects on the cell culture

  14. Serum herpes simplex antibodies

    Science.gov (United States)

    ... causes cold sores (oral herpes). HSV-2 causes genital herpes. How the Test is Performed A blood sample ... person has ever been infected with oral or genital herpes . It looks for antibodies to herpes simplex virus ...

  15. Study of Serum Amylase and Serum Cholinesterase in Organophosphorus Poisoning

    Directory of Open Access Journals (Sweden)

    Sharan Badiger

    2016-04-01

    Full Text Available Background: Poisoning due to organophosphorus compounds is most commonly seen. Earlier plasma cholinesterase level was used to assess the severity of poisoning. Presently serum amylase is being recommended as a better indicator of severity. Aims and Objectives: To study plasma cholinesterase and serum amylase levels in acute organophosphorus and to correlate serum amylase levels with clinical severity and outcome. Material and Methods: A total of 80 patients in the study admitted to a tertiary care centre within 24 hours with a history of organophosphorus poisoning were included in study. Estimation of plasma cholinesterase and serum rd amylase was done at the time of admission, and on 3 th day and on 5 day. Results: Occurrence of organophosphorus poisoning was more common among age group 21-30 years and among males (57.5%. They were 25 (31.2% farmers, 23 (28.8% st u d e n ts, a n d 2 2 ( 2 7 . 5% h o u s ewi v e s. Monocrotophos (45.0% was commonly used compound. Mean value of plasma cholinesterase and serum amylase at admission are 3693 U/L, and 185.4 U/L. There was significant inhibition of plasma cholinesterase and elevation of serum amylase at th admission with return to normal values on 5 day. Conclusion: Plasma cholinesterase inhibition 200 U/L has been associated with poor prognosis and proneness to respiratory failure.

  16. Calcium Blood Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  17. Serum selenium level and risk of lung cancer mortality

    DEFF Research Database (Denmark)

    Suadicani, P; Hein, H O; Gyntelberg, F

    2011-01-01

    Serum selenium has been implicated as a risk factor for lung cancer, but the issue remains unsettled. We tested in a cohort of 3,333 males aged 53 to 74 years the hypothesis that a low serum selenium would be associated with an increased risk of lung cancer mortality.During 16 years, 167 subjects(5.......1%) died from lung cancer; 48 males (5.0%) among males with low serum selenium, 0.4-1.0 μmol·l(-1), n=965, 57 males (5.1%) among males with medium serum selenium, 1.1-1.2 μmol·l(-1), n=1,141, and 62 males (5.1%) among males with high serum selenium, 1.3-3.0 μmol·l(-1), n=1,227. After adjustment for age...... (chronic bronchitis and peak flow), referencing the lowest level of serum selenium HRs were 1.17(0.79-1.75), and 1.43(0.96-2.14), respectively. Among heavy smokers a high serum selenium was associated with a significantly increased risk of lung cancer mortality after taking into account all potential...

  18. Influence of feeding on serum canine pancreatic lipase immunoreactivity concentrations

    Directory of Open Access Journals (Sweden)

    Steiner JM

    2014-10-01

    Full Text Available Jörg M Steiner, Craig G Ruaux, David A Williams Gastrointestinal Laboratory, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA Abstract: Measurement of serum concentration of pancreatic lipase immunoreactivity (PLI has been shown to be highly specific for exocrine pancreatic function and sensitive for the diagnosis of canine pancreatitis. Currently, it is recommended that food be withheld for at least 12 hours before collecting a blood sample for analysis from dogs. However, it is unknown whether feeding has any influence on serum canine PLI concentration. Thus, the goal of this study was to evaluate the influence of feeding on serum canine PLI concentrations in healthy dogs. Food was withheld from eight healthy adult Beagle dogs for at least 17 hours and a baseline serum sample (0 minutes was collected. Dogs were fed and serum samples were collected at 15, 30, 45, 60, 75, 90, 105, 150, 180, 210, 240, 300, 360, 420, and 480 minutes. There was no significant difference in serum canine PLI concentrations at any time after feeding (P=0.131. We conclude that feeding has no significant influence on serum canine PLI concentrations. Keywords: dog, pancreatic function, pancreatitis, biomarker, diagnostic test

  19. CO2 blood test

    Science.gov (United States)

    Bicarbonate test; HCO3-; Carbon dioxide test; TCO2; Total CO2; CO2 test - serum; Acidosis - CO2; Alkalosis - CO2 ... Many medicines can interfere with blood test results. Your health ... need to stop taking any medicines before you have this test. DO ...

  20. Serum albumin: accuracy and clinical use.

    Science.gov (United States)

    Infusino, Ilenia; Panteghini, Mauro

    2013-04-18

    Albumin is the major plasma protein and its determination is used for the prognostic assessment of several diseases. Clinical guidelines call for monitoring of serum albumin with specific target cut-offs that are independent of the assay used. This requires accurate and equivalent results among different commercially available methods (i.e., result standardization) through a consistent definition and application of a reference measurement system. This should be associated with the definition of measurement uncertainty goals based on medical relevance of serum albumin to make results reliable for patient management. In this paper, we show that, in the current situation, if one applies analytical goals for serum albumin measurement derived from its biologic variation, the uncertainty budget derived from each step of the albumin traceability chain is probably too high to fulfil established quality levels for albumin measurement and to guarantee the accuracy needed for clinical usefulness of the test. The situation is further worsened if non-specific colorimetric methods are used for albumin measurement as they represent an additional random source of uncertainty. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Correlations Between Macular, Skin, and Serum Carotenoids

    Science.gov (United States)

    Conrady, Christopher D.; Bell, James P.; Besch, Brian M.; Gorusupudi, Aruna; Farnsworth, Kelliann; Ermakov, Igor; Sharifzadeh, Mohsen; Ermakova, Maia; Gellermann, Werner; Bernstein, Paul S.

    2017-01-01

    Purpose Ocular and systemic measurement and imaging of the macular carotenoids lutein and zeaxanthin have been employed extensively as potential biomarkers of AMD risk. In this study, we systematically compare dual wavelength retinal autofluorescence imaging (AFI) of macular pigment with skin resonance Raman spectroscopy (RRS) and serum carotenoid levels in a clinic-based population. Methods Eighty-eight patients were recruited from retina and general ophthalmology practices from a tertiary referral center and excluded only if they did not have all three modalities tested, had a diagnosis of macular telangiectasia (MacTel) or Stargardt disease, or had poor AFI image quality. Skin, macular, and serum carotenoid levels were measured by RRS, AFI, and HPLC, respectively. Results Skin RRS measurements and serum zeaxanthin concentrations correlated most strongly with AFI macular pigment volume under the curve (MPVUC) measurements up to 9° eccentricity relative to MPVUC or rotationally averaged macular pigment optical density (MPOD) measurements at smaller eccentricities. These measurements were reproducible and not significantly affected by cataracts. We also found that these techniques could readily identify subjects taking oral carotenoid-containing supplements. Conclusions Larger macular pigment volume AFI and skin RRS measurements are noninvasive, objective, and reliable methods to assess ocular and systemic carotenoid levels. They are an attractive alternative to psychophysical and optical methods that measure MPOD at a limited number of eccentricities. Consequently, skin RRS and MPVUC at 9° are both reasonable biomarkers of macular carotenoid status that could be readily adapted to research and clinical settings. PMID:28728169

  2. Serum YKL-40 in risk assessment for colorectal cancer

    DEFF Research Database (Denmark)

    Johansen, Julia Sidenius; Christensen, Ib Jarle; Jørgensen, Lars Nannestad

    2015-01-01

    The aim of the present study was to test the hypothesis that high serum YKL-40 associates with colorectal cancer in subjects at risk of colorectal cancer. We measured serum YKL-40 in a prospective study of 4,496 Danish subjects [2,064 men, 2,432 women, median age 61 years (range, 18-97)] referred.......05-1.40; P = 0.012), whereas this was not the case for those with comorbidity (OR, 0.98; 95% CI, 0.84-1.14; P = 0.80). In conclusion, high serum YKL-40 in subjects suspected of colorectal cancer and without comorbidity associates with colorectal cancer. Determination of serum YKL-40 may be useful...

  3. The reference range of serum, plasma and erythrocyte magnesium

    Directory of Open Access Journals (Sweden)

    Suzanna Immanuel

    2006-12-01

    Full Text Available The interest in the clinical importance of serum magnesium level has just recently begun with the analysis and findings of abnormal magnesium level in cardiovascular, metabolic and neuromuscular disorder. Although the serum level does not reflect the body magnesium level, but currently, only serum magnesium determination is widely used. Erythrocyte magnesium is considered more sensitive than serum magnesium as it reflects intracellular magnesium status. According to NCCLS (National Committee for Clinical Laboratory Standards every laboratory is recommended to have its own reference range for the tests it performs, including magnesium determination. The reference range obtained is appropriate for the population and affected by the method and technique. This study aimed to find the reference range of serum and plasma magnesium and also intracellular magnesium i.e. erythrocyte magnesium by direct method, and compare the results of serum and plasma magnesium. Blood was taken from 114-blood donor from Unit Transfusi Darah Daerah (UTDD Budhyarto Palang Merah Indonesia (PMI DKI Jakarta, consisted of 57 male and 57 female, aged 17 – 65 years, clinically healthy according to PMI donor criteria. Blood was taken from blood set, collected into 4 ml vacuum tube without anticoagulant for serum magnesium determination and 3 ml vacuum tube with lithium heparin for determination of erythrocyte and plasma magnesium Determination of magnesium level was performed with clinical chemistry auto analyzer Hitachi 912 by Xylidil Blue method colorimetrically. This study showed no significant difference between serum and heparinized plasma extra cellular magnesium. The reference range for serum or plasma magnesium was 1.30 – 2.00 mEq/L and for erythrocyte magnesium was 4.46 - 7.10 mEq/L. (Med J Indones 2006; 15:229-35Keywords: Reference range, extracellular magnesium, intracellular magnesium

  4. Pretreated high lipid serum method and its significance before determine INS C-P by RIA

    International Nuclear Information System (INIS)

    Wan Guangxia; Zhu Liqiang; Wu Yufang

    2004-01-01

    The method of predigest high lipid serum before determine INS and C-P for elimination of the high lipid in serum was studied. The specimen was divided into two groups, one was directly tested, the other was pretreated, then determined(including INS and QC of serum, normal and high lipid serum, pretreating serum). The results were compared by examine and analysed correlatively. Results show that INS and C-P of the specimens pretreated by PEG, were no statistic difference in relation to direct tested (P>0.05) and those were close correlatively (P<0.001) in normal. The results of high lipid serum after the specimens were predigest by PEG were marked by decrease in relation to direct tested (P<0.001). High lipid and INS antibody were eliminated by PEG so that was increased the results nicety. (authors)

  5. Serum antinuclear antibody in adult Thais.

    Science.gov (United States)

    Prapinjumrune, Chanwit; Prucktrakul, Chalakorn; Sooktonglarng, Trakarn; Thongprasom, Kobkan

    2017-03-01

    This study investigated the presence of antinuclear antibody (ANA) in older Thais compared with middle-age and younger participants. Antinuclear antibody represents the first step in the diagnostic testing for lupus erythematosus (LE) and other autoimmune diseases. Due to the lack of reference ANA levels in older, middle-age and younger Thais healthy participants, this study will be useful for determining the proper diagnostic and treatment criteria. There were 28 older (60-76 years), 17 middle-age (41-59 years) and 13 younger (24-40 years) participants in this study. Immunofluorescence was performed to analyse the ANA staining pattern and titre levels in the participants' blood samples. The presence of serum ANA was found in 18 of 28 cases (64.3%), four of 17 (23.5%) and one of 13 cases (7.7%) of the older, middle-age and younger participants, respectively. The difference in the number of serum ANA-positive participants between the older, middle-age and younger groups was statistically significant (p < 0.05). Interestingly, the ANA positive in older participants presented more than one staining pattern. The speckled pattern was the most commonly detected ANA staining pattern in the older group, being found in 12 cases followed by cytoplasmic pattern (10 cases), homogeneous pattern (nine cases) and nucleolar pattern (five cases). In the middle-age group, the speckled pattern was found in four cases, whereas one younger participant presented a nucleolar pattern. Serum ANA positive was significantly higher in the older group compared with the middle-age and younger groups. There were variations of the serum ANA staining patterns in the older group. © 2016 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  6. The elevated serum urea:creatinine ratio in canine babesiosis in South Africa is not of renal origin.

    Science.gov (United States)

    de Scally, M P; Leisewitz, A L; Lobetti, R G; Thompson, P N

    2006-12-01

    Pigmented serum, usually due to free haemoglobin and/or bilirubin, is a common finding in dogs with babesiosis, resulting in interference with all biochemical tests that rely on photochemistry. This is particularly true of urea and creatinine determinations, complicating the diagnosis of acute renal failure, which is a serious complication of babesiosis. A disproportionately raised serum urea concentration of unknown origin occurs in severely anaemic canine babesiosis patients and gives rise to an increased serum urea:creatinine ratio. The assay for cystatin-C, an excellent measure of glomerular filtration rate, is unaffected by free serum haemoglobin, and due to its different intrinsic origins, is free of influence by the metabolic derangements and organ pathology, other than renal disease, encountered in canine babesiosis. Serum cystatin-C was used to compare the concentrations of serum urea and serum creatinine in dogs with the severely anaemic form of canine babesiosis as well as a canine babesiosis-free reference group. Mean serum urea and mean serum urea:creatinine ratio were significantly elevated in the babesia-infected group relative to the reference population in this study. Mean serum creatinine and mean serum cystatin-C were within the reference ranges. Therefore an elevated urea:creatinine ratio in canine babesiosis in the presence of a normal serum creatinine concentration is considered to be caused by an elevated serum urea concentration and is most likely of non-renal origin. Serum creatinine was therefore as specific a measure of renal function as serum cystatin-C in canine babesiosis in this study. The sensitivity of serum creatinine as a measure of renal function was not established by this study. Serum urea, however, proved to be of little use compared to serum cystatin-C and serum creatinine. Serum urea should therefore not be used to diagnose renal failure in canine babesiosis.

  7. Testing Testing Testing.

    Science.gov (United States)

    Deville, Craig; O'Neill, Thomas; Wright, Benjamin D.; Woodcock, Richard W.; Munoz-Sandoval, Ana; Gershon, Richard C.; Bergstrom, Betty

    1998-01-01

    Articles in this special section consider (1) flow in test taking (Craig Deville); (2) testwiseness (Thomas O'Neill); (3) test length (Benjamin Wright); (4) cross-language test equating (Richard W. Woodcock and Ana Munoz-Sandoval); (5) computer-assisted testing and testwiseness (Richard Gershon and Betty Bergstrom); and (6) Web-enhanced testing…

  8. Serum alkaline phosphatase screening for vitamin D deficiency states

    International Nuclear Information System (INIS)

    Shaheen, S.; Barrakzai, Q.

    2012-01-01

    Objective: To determine whether serum vitamin D levels are correlated with serum levels of alkaline phosphatase or not. Study Design: Cross-sectional, observational study. Place and Duration of Study: Multi-centre study, conducted at Liaquat National Hospital and Medical College, National Medical Centre and Medicare Hospital, Karachi, from January to October 2009. Methodology: Patients attending the Orthopaedic OPDs with complaints of pain in different body regions and serum vitamin D/sub 3/ levels of greater or equal to 30 ng/ml were included in the study. Patients with vitamin D deficiency were further categorized into mild deficiency or insufficiency (vit. D/sub 3/ = 20-29 ng/ml), moderate deficiency (vit. D/sub 3/ = 5 - 19 ng/ml) and severe deficiency forms (vit. D/sub 3/ < 5 ng/ml). Pearson correlation was applied to test the correlation of serum alkaline phosphatase levels with serum vitamin D/sub 3/ levels. P-value < 0.05 was considered to be significant. Results: Out of 110 samples, 26 had mild (23%), 61 had moderate (55%) and 21 had severe (19.1%) vitamin D deficiencies. All of the patients in the three groups had alkaline phosphatase with in normal limits and the total mean value of the enzyme was 135.97 +- 68.14I U/L. The inter group comparison showed highest values of alkaline phosphatase in the moderate vitamin D deficiency group. The correlation coefficient of alkaline phosphatase and serum vitamin D/sub 3/ levels was r =0.05 (p =0.593). Conclusion: Serum vitamin D/sub 3/ levels may not be correlated with increased serum alkaline phosphatase levels. Therefore, alkaline phosphatase may not be used as a screening test to rule out vitamin D deficiency. (author)

  9. SERUM SODIUM CHANGES IN NEONATES RECEIVING PHOTOTHERAPY FOR NEONATAL HYPERBILIRUBINEMIA

    Directory of Open Access Journals (Sweden)

    Sunil Kumar

    2015-07-01

    Full Text Available BACKGROUND : Neonates receiving phototherapy have side effects like hypocalcemia and electrolyte changes. Our study is hereby intended to study the serum sodium changes due to phototherapy. AIMS : To evaluate the serum sodium changes in neonates receiving phototherapy f or neonatal hyperbilirubinemia. SETTINGS AND DESIGN : A prospective hospital based comparative study conducted on neonates admitted in the Neonatal Intensive Care Unit receiving phototherapy. METHODS AND MATERIAL : A predesigned proforma has aided the enroll ment of 252 newborns into the study. Serum bilirubin and serum sodium were determined before and after termination of phototherapy. The first samples were considered as controls. A comparative study was made between before and after phototherapy groups to determine the incidence of serum sodium imbalances. STATISTICAL ANALYSIS USED : Proportions will be compared using chi - square test. All data of various groups will be tabulated and statistically analyzed using suitable statistical tests (Student's t test. RESULTS : Male to Female ratio was 1.45 : 1. Incidence of low birth weight babies was 23% and preterm was 20.2%. Mean birth weight and gestational age was 2.84±0.51 kg and 38.44±1.98 wks respectively. Mean duration of phototherapy was 37.65±11.06 hrs. The incidence of hyponatremia post phototherapy found to be 6% which was more in low birth weight (LBW babies (17.2% , p48 hrs (p<0.001. Even the decline in mean serum sodium values after phototherapy found to be statistically significant. CONCLUSION : Our study shows that neonates u nder phototherapy are at higher risk of hyponatremia. This risk is greater in premature and LBW babies and hence this group of babies should be closely monitored for changes in serum sodium and should be managed accordingly.

  10. The influence of serum substituents on serum-free Vero cell conditioned culture media manufactured from Dulbecco's modified Eagle medium in mouse embryo culture.

    Science.gov (United States)

    Lee, Jong-Seon; Kim, Ju-Hwan; Seo, Young-Seok; Yang, Jung-Bo; Kim, Yong-Il; Kim, Hye-Jin; Lee, Ki-Hwan

    2013-09-01

    This study was conducted to examine the influences of supplementation of the serum substituents and available period of serum-free Vero cell conditioned media (SF-VCM) manufactured from Dulbecco's modified Eagle medium cultured with Vero cells for in vitro development of mouse preimplantation embryos. A total of 1,099 two-cell embryos collected from imprinting control region mice were cultured in SF-VCM with 10% and 20% human follicular fluid (hFF), serum substitute supplement (SSS), and serum protein substitute (SPS). Development of embryos was observed every 24 hours. Results between different groups were analyzed by chi-square test, and considered statistically significant when P-value was less than 0.05. The rates of embryonic development cultured in SF-VCM supplemented with serum substituents were significantly higher compare with serum-free group (P media up to 4 weeks did not affect on embryonic development.

  11. Serum prolactin revisited

    DEFF Research Database (Denmark)

    Overgaard, Martin; Pedersen, Susanne Møller

    2017-01-01

    regimes across commonly used automated immunoassay platforms. METHODS: Parametric total and monomeric gender-specific reference intervals were determined for six immunoassay methods using female (n=96) and male sera (n=127) from healthy donors. The reference intervals were validated using 27...... and macroprolactinemic; n=27) showed higher discordant classification [mean=2.8; 95% confidence interval (CI) 1.2-4.4] for the monomer reference interval method compared to the post-polyethylene glycol (PEG) recovery cutoff method (mean=1.8; 95% CI 0.8-2.8). The two monomer/macroprolactin discrimination methods did...... not differ significantly (p=0.089). Among macroprolactinemic sera evaluated by both discrimination methods, the Cobas and Architect/Kryptor prolactin assays showed the lowest and the highest number of misclassifications, respectively. CONCLUSIONS: Current automated immunoassays for prolactin testing require...

  12. Osteoprotegerin Serum Levels in Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Kolarz G

    2003-01-01

    Full Text Available Osteoprotegerin (OPG wird in der entzündeten Synovialis bei chronischer Polyarthritis von Makrophagen, dendritischen Zellen und B-Zellen produziert. OPG hemmt die Differenzierung von Osteoklasten und ihre Aktivierung durch die Bindung an RANKL (receptor activator of NFkappaBbeta ligand. OPG könnte daher eine wichtige Rolle in der Verhinderung des Auftretens von Erosionen bei chronischer Polyarthritis spielen. In der vorliegenden Studie wurde untersucht, ob die Serumspiegel von Osteoprotegerin mit Entzündungsparametern oder der Gelenksdestruktion bei chronischer Polyarthritiskorrelieren. Patienten und Methoden: In 85 Sera von 68 Patienten mit chronischer Polyarthritis wurden die Serumspiegel von OPG untersucht und mit klinischen Parametern, Laborbefunden und dem Larsen-Score verglichen. Zur OPG-Bestimmung wurde ein Sandwich-ELISA (enzyme-linked-im-munosorbent-assay mit zwei spezifischen OPG-Antikörpern verwendet. Mit dem bindenden Antikörper wurde eine Mikrotiterplatte beladen, der zweite Biotin-konjugierte Antikörper wurde durch Streptavidin-Peroxidase und TMB gemessen. Der Immunoassay mißt sowohl freies als auch an RANKL gebundenes OPG. Zur statistischen Auswertung wurde ein SAS-Programm verwendet, als Tests wurden der Mann-Whitney-Test, die Spearman-Korrelation und die Varianzanalyse (ANOVA angewandt. Ergebnisse: Verglichen mit einer gesunden Kontrollgruppe (Alter 56-76 Jahre lagen die Mittelwerte von Serum-OPG bei chronischer Polyarthritis höher. Wenn man den Mittelwert der Gesunden für die Einteilung in höhere oder niedrigere Serum-OPG-Werte bei Patienten mit chronischer Polyarthritis verwendet, zeigt sich im Mann-Whitney-Test eine signifikante Korrelation nicht nur mit BSG und Rheumafaktor, sondern auch mit dem Larsen-Score. Die OPG-Spiegel korrelierten mit dem Rheumafaktor, der BSG und dem Serum-CRP (C-reaktives Protein signifikant positiv, der Larsen-Score zeigte nur einen statistischen Trend. Diskussion: OPG blockiert die

  13. Which Exercise Is Better for Increasing Serum Testosterone Levels in Patients with Erectile Dysfunction?

    Directory of Open Access Journals (Sweden)

    Jeong Kyun Yeo

    2018-05-01

    Full Text Available Purpose: We investigated the correlations of serum total testosterone (TT levels with body composition and physical fitness parameters in patients with erectile dysfunction (ED to know the best exercise for testosterone deficiency. Materials and Methods: Eighty-seven ED patients underwent serum TT assessment as well as body composition and basic exercise testing. The bioelectrical impedance analysis was used to assess body composition. Seven types of basic exercise tests were used to determine physical fitness. Correlations between serum TT levels and body composition/physical function parameters were evaluated using partial correlation analyses. A serum TT cut-off value was obtained for the parameters significantly correlated with serum TT levels. Results: The subjects had a mean serum TT level of 342.1 ng/dL. Among the body composition parameters, body and abdominal fat percentages showed statistically significant negative correlations with serum TT levels. Among the basic exercise test parameters, only the cycle ergometer test for cardiorespiratory fitness showed a statistically significant positive correlation with serum TT levels. Conclusions: Serum TT levels in patients with ED, may be increased by reducing fat percentage and improving cardiorespiratory fitness via aerobic exercise.

  14. Multiple free-radical scavenging (MULTIS) capacity in cattle serum.

    Science.gov (United States)

    Sueishi, Yoshimi; Kamogawa, Erisa; Kimura, Anna; Kitahara, Go; Satoh, Hiroyuki; Asanuma, Taketoshi; Oowada, Shigeru

    2017-01-01

    Multiple free-radical scavenging (MULTIS) activity in cattle and human sera was evaluated with electron spin resonance spectroscopy. Scavenging rates against six active species, namely hydroxyl radical, superoxide anion, alkoxyl radical, alkylperoxyl radical, methyl radical, and singlet oxygen were quantified. The difference in the electron spin resonance signal intensity in the presence and absence of the serum was converted into the scavenging rates. Comparative MULTIS measurements were made in sera from eight beef cattle, three fetal calves and fifteen healthy human volunteers. Further, we determined the MULTIS value of albumin, the most abundant component in serum. MULTIS values in cattle sera indicated higher scavenging activity against most free radical species tested than human sera. In particular, cattle serum scavenging activities against superoxide and methyl radical were higher than human serum by 2.6 and 3.7 fold, respectively. In cattle serum, albumin appears to play a dominant role in MULTIS activity, but in human serum that is not the case. Previous data indicated that the abundance of uric acid in bovine blood is nearly 80% less than humans; however, this difference does not explain the deviation in MULTIS profile.

  15. Grizzly bear corticosteroid binding globulin: Cloning and serum protein expression.

    Science.gov (United States)

    Chow, Brian A; Hamilton, Jason; Alsop, Derek; Cattet, Marc R L; Stenhouse, Gordon; Vijayan, Mathilakath M

    2010-06-01

    Serum corticosteroid levels are routinely measured as markers of stress in wild animals. However, corticosteroid levels rise rapidly in response to the acute stress of capture and restraint for sampling, limiting its use as an indicator of chronic stress. We hypothesized that serum corticosteroid binding globulin (CBG), the primary transport protein for corticosteroids in circulation, may be a better marker of the stress status prior to capture in grizzly bears (Ursus arctos). To test this, a full-length CBG cDNA was cloned and sequenced from grizzly bear testis and polyclonal antibodies were generated for detection of this protein in bear sera. The deduced nucleotide and protein sequences were 1218 bp and 405 amino acids, respectively. Multiple sequence alignments showed that grizzly bear CBG (gbCBG) was 90% and 83% identical to the dog CBG nucleotide and amino acid sequences, respectively. The affinity purified rabbit gbCBG antiserum detected grizzly bear but not human CBG. There were no sex differences in serum total cortisol concentration, while CBG expression was significantly higher in adult females compared to males. Serum cortisol levels were significantly higher in bears captured by leg-hold snare compared to those captured by remote drug delivery from helicopter. However, serum CBG expression between these two groups did not differ significantly. Overall, serum CBG levels may be a better marker of chronic stress, especially because this protein is not modulated by the stress of capture and restraint in grizzly bears. Copyright 2010 Elsevier Inc. All rights reserved.

  16. Diurnal variations of serum erythropoietin at sea level and altitude

    DEFF Research Database (Denmark)

    Klausen, T; Poulsen, T D; Fogh-Andersen, N

    1996-01-01

    in 2, 3 diphosphoglycerate. After 64 h at altitude, six of the nine subjects had down-regulated their serum-EPO concentrations so that median values were three times above those at sea level. These six subjects had significant diurnal variations of serum-EPO concentration at sea level; the nadir......This study tested the hypothesis that the diurnal variations of serum-erythropoietin concentration (serum-EPO) observed in normoxia also exist in hypoxia. The study also attempted to investigate the regulation of EPO production during sustained hypoxia. Nine subjects were investigated at sea level...... and during 4 days at an altitude of 4350 m. Median sea level serum-EPO concentration was 6 (range 6-13) U.l-1. Serum-EPO concentration increased after 18 and 42 h at altitude, [58 (range 39-240) and 54 (range 36-340) U.l-1, respectively], and then decreased after 64 and 88 h at altitude [34 (range 18...

  17. Opium and heroin alter biochemical parameters of human's serum.

    Science.gov (United States)

    Kouros, Divsalar; Tahereh, Haghpanah; Mohammadreza, Afarinesh; Minoo, Mahmoudi Zarandi

    2010-05-01

    Iran is a significant consumer of opium, and, generally, of opioids, in the world. Addiction is one of the important issues of the 21st century and is an imperative issue in Iran. Long-term consumption of opioids affects homeostasis. To determine the effects of opium and heroin consumption on serum biochemical parameters. In a cross-sectional study, subjects who had consumed heroin (n = 35) or opium (n = 42) for more than two years and 35 nonaddict volunteers as the control group were compared in regard to various biochemical parameters such as fasting blood sugar (FBS), Na(+), K(+), Ca(2+), blood urea nitrogen (BUN), uric acid (UA), triglyceride (TG), cholesterol, creatinine, and total protein. Chromatography was used to confirm opioid consumption, and the concentration of biochemical parameters was determined by laboratory diagnostic tests on serum. No significant differences were found in Na(+), Ca(2+), BUN, UA, TG, creatinine, and total protein concentrations among the three groups. FBS, K(+), and UA levels were significantly lower in opium addicts compared to the control group. Serum Ca(2+) concentration of heroin addicts showed a significant decrease compared to that of the control group. Both addict groups showed a significant decrease in serum cholesterol levels. Chronic use of opium and heroin can change serum FBS, K(+), Ca(2+), UA, and cholesterol. This study, one of few on the effects of opium on serum biochemical parameters in human subjects, has the potential to contribute to the investigation of new approaches for further basic studies.

  18. Serum protein inhibition of thyrotropin binding to human thyroid tissue

    International Nuclear Information System (INIS)

    Beall, G.N.; Chopra, I.J.; Solomon, D.H.; Kruger, S.R.

    1978-01-01

    We used a modificaton of the TSH radioreceptor assay to detect TSH-binding inhibition (TBI) activity in serum and serum fractions from normal subjects and patients with Graves' disease. TBI activity is present in normal IgG prepared by DEAE-Sephadex chromatography and in normal globulins prepared by precipitation at 1.6 M ammonium sulfate. Other normal serum proteins also had TBI activity when large concentrations were tested. Gel filtration chromatography and powder block electrophoresis were used to prepare fractions of normal and Graves' disease sera. In these fractions from normal serum, TBI activity was found in both γ-globulin and α-globulin-albumin fractions electrophoretically and in both 7S and 4S peaks from gel filtration. TBI activity from Graves' disease patients' sera was similarly distributed, but relatively more TBI accompanied the electrophoretic γ-globulins. Sepharose Protein-A and anti-IgG were used as immunoabsorbents to isolate and purify IgG from normal and Graves' disease sera. TBI activity in IgG was proportional to the IgG concentration, indicating that the TBI which migrates as a γ-globulin electrophoretically is an IgG and thus may possibly be an antibody. Inhibitory activity found in normal serum globulins and in the non-IgG fractions of both normal and abnormal sera seriously interferes with attempts to use the TSH radioreceptor assay to study the hypothesized anti-TSH receptor antibody in the serum of patients with Graves' disease

  19. Genetic determinants of serum vitamin B12 and their relation to body mass index

    DEFF Research Database (Denmark)

    Allin, Kristine H.; Friedrich, Nele; Pietzner, Maik

    2017-01-01

    for associations between (1) serum vitamin B12 levels and body mass index (BMI), (2) genetic variants and serum vitamin B12 levels, and (3) genetic variants and BMI. The effect of a genetically determined decrease in serum vitamin B12 on BMI was estimated by instrumental variable regression. Decreased serum......Lower serum vitamin B12 levels have been related to adverse metabolic health profiles, including adiposity. We used a Mendelian randomization design to test whether this relation might be causal. We included two Danish population-based studies (ntotal = 9311). Linear regression was used to test...... vitamin B12 associated with increased BMI (P vitamin B12 associated variants associated strongly with serum vitamin B12 (P vitamin B12...

  20. Potassium Blood Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Potassium, Serum; 426–27 p. Lab ...

  1. Chloride test - blood

    Science.gov (United States)

    Serum chloride test ... A greater-than-normal level of chloride is called hyperchloremia. It may be due to: Carbonic anhydrase inhibitors (used to treat glaucoma) Diarrhea Metabolic acidosis Respiratory alkalosis (compensated) Renal ...

  2. Osteocalcin and serum insulin-like growth factor-1 as biochemical skeletal maturity indicators

    Directory of Open Access Journals (Sweden)

    Tulika Tripathi

    2017-10-01

    Full Text Available Abstract Background With change in concepts of growth determination methods, there is a surge in the measurement of biomarkers for appraisal of growth status. Osteocalcin is a bone-specific protein and was observed to parallel the normal growth curve. Hence, the present study was intended to assess the levels of serum osteocalcin and serum insulin-like growth factor-1 (IGF-1 and compare them with cervical vertebral maturation index (CVMI stages. Methods The cross-sectional study was performed on 150 subjects (75 males and 75 females in the age group of 8–20 years and segregated into six CVMI stages. Serum osteocalcin and IGF-1 were estimated by ELISA. Mann-Whitney U test was used to compare the mean ranks of serum osteocalcin and serum IGF-1 with different CVMI stages. Spearman correlation was performed to find association between serum osteocalcin and serum IGF-1 across six CVMI stages. Results Peak serum IGF-1 levels were obtained at CVMI stages 4 and 3 for males and females, respectively, with insignificant difference between stages 3 and 4 in females. Peak serum osteocalcin levels were found at stage 5 and 3 for males and females with insignificant difference from other stages except stages 5 and 6 in males. A statistically significant correlation was seen between serum IGF-1 and serum osteocalcin across six CVMI stages (P < 0.01. Conclusions Osteocalcin followed IGF-1 across all CVMI stages but showed insignificant interstage differences.

  3. Serum Copper and Plasma Protein Status in Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    Nushrat Noor, Nasim Jahan, Nayma Sultana

    2012-12-01

    Full Text Available AbstractBackground: Gradual alteration of serum copper and some plasma protein levels may occur with advancement of pregnancy, which is associated with increased maternal and infant morbidity and mortality.Objective: To observe serum copper and plasma protein levels in normal pregnant women of different trimesters in order to find out their nutritional status.Methods: This cross sectional study was carried out in the Department of Physiology, Sir Salimullah Medical College (SSMC, Dhaka, between 1st January 2010 and December 2010. Ninety normal pregnant women of different trimesters with age 20-30 years were included in the study group. They were selected from Out Patient Department of Obstetrics and Gynaecology, SSMC. Age matched 30 non-pregnant women were taken as control. Serum copper level was measured by Spectrophotometric method, serum total protein and albumin levels were estimated by standard method. Statistical analysis was done by one way ANOVA, Bonferroni and Pearson’s correlation coefficient test as applicable.Results: Serum Cu levels were significantly higher in all trimesters of pregnant women compared to control. Again, this value was significantly higher in 3rd trimester than that of in 1st and 2nd trimester and also in 2nd trimester than that of in 1st trimester. In addition, mean serum total protein level was significantly lower in 3rd trimester than control but no statistically significant difference was observed among different trimesters. Again, mean serum albumin level was significantly lower in 2nd and 3rd trimester than 1st trimester and control. In addition, serum Cu concentration showed significant positive correlation with different trimesters of gestation.Conclusion: This study reveals that hypercupremia along with hypoproteinemia occur in pregnant women from 1st to 3rd trimester of gestation. This gradual alteration of micro and macronutrients become more profound with advancement of pregnancy.

  4. Intrathecal antitetanus serum (horse) with steroid in the treatment of neonatal tetanus.

    OpenAIRE

    Singh, A K; Bansal, A; Goel, S P; Agarwal, V K

    1980-01-01

    107 patients with neonatal tetanus were studied and the value of intrathecal antitetanus serum with steroid was noted. The mortality rate in a control group (68%) was significantly higher than that of the test group (37%). Furthermore, a delay in antitetanus serum administration was found to have a strong positive linear correlation with the mortality rate. In fact, the mortality rate for neonates who were given antitetanus serum 24 hours after the onset of convulsions was found to be as high...

  5. Precision and costs of techniques for self-monitoring of serum glucose levels.

    OpenAIRE

    Chiasson, J. L.; Morrisset, R.; Hamet, P.

    1984-01-01

    The poor correlation between serum and urine glucose measurements has led to the development of new techniques for monitoring the blood glucose level in diabetic patients. Either a nurse or the patient can perform these tests, which involve spreading a single drop of blood onto a reagent strip. A colour change that is proportional to the serum glucose level can be read visually or with a reflectance meter. Evaluated against simultaneous serum glucose levels determined by the hospital biochemi...

  6. Lecithin intake and serum cholesterol.

    NARCIS (Netherlands)

    Knuiman, J.T.; Beynen, A.C.; Katan, M.B.

    1989-01-01

    To find out whether the consumption of lecithin has a more beneficial effect on serum cholesterol than does the consumption of equivalent amounts of polyunsaturated oils, we scrutinized 24 studies on the effect of supplementary lecithin intakes ranging from 1 to 54 mg/d. Most of the studies lacked

  7. Serum transferrin receptor in polycythemia.

    Science.gov (United States)

    Manteiga, R; Remacha, A F; Sardà, M P; Ubeda, J

    1998-10-01

    We measured serum transferrin receptor (sTfR) levels in 22 patients with polycythemia vera and in 26 cases of secondary polycythemia. In our study, raised sTfR levels in both polycythemia groups were related to iron deficiency.

  8. Serum zinc level in thalassemia

    International Nuclear Information System (INIS)

    Keikhaei, B.; Badavi, M.; Pedram, M.; Zandian, K.

    2010-01-01

    To compare serum zinc level between Thalassemia Major (TM) patients and normal population at Shafa Hospital in South West of Iran. A total of 25 male and 36 female of TM patients were enrolled in this study. Out of 61 patients thirty were treated by deferroxamine (DFO) and 31 were on the combination of DFO and deferiprone (DEF) protocol therapy. Sixty normal subjects of the matching age and gender were recruited as controls. From each patient and control group 2 ml of blood was taken in fasting condition. Cell blood count and serum zinc were carried out for both thalassemia patients and normal subjects. The mean age of patients and control group was 15+- 5 years. Mean serum zinc level was 68.97+- 21.12 mu g/dl, 78.10-28.50 mu g/dl, and 80.16+- 26.54 mu g/dl in the TM with DFO, TM with DFO + DEF combination protocol and control group respectively. There was no significant correlation between patients and control group. However 50 percent of TM with DFO, 38.7 percent of TM with DFO + DEF and 32.8 percent of control group had hypozincemia. Nearly 40 to 50 percent of TM patients and one third of normal subjects are suffering from hypozincemia. This study shows that low level of serum zinc is a health problem in both thalassemia patients and normal population in South West of Iran. (author)

  9. Comparison of serum lipid profile in ischaemic and haemorrhagic stroke

    International Nuclear Information System (INIS)

    Mehmood, A.; Sharif, M.A.

    2010-01-01

    To compare serum lipid profile between patients of ischaemic and haemorrhagic strokes. Study Design: Cross sectional, comparative study. Place and Duration of Study: Military Hospital, Rawalpindi, from August 2004 to February 2005. Methodology: Patients with diagnosis of stroke comprising 100 consecutive patients each of ischaemic and haemorrhagic strokes were included in the study while patients on lipid lowering therapy were excluded from study. To determine the subtype of stroke, clinical examination followed by CT scan of brain was done. A serum sample after 8 hours of overnight fasting was taken on the next day of admission for both groups of patients. Total serum cholesterol, triglycerides, LDL cholesterol, VLDL-cholesterol and HDL-cholesterol was determined, using enzymatic colorimetric method. Statistical analysis was done by comparison of lipid profile in two subgroups, using proportion test for any significant difference. Results: The mean age at presentation of patients with stroke was 64.2+-12 years with a male to female ratio of 3.6:1. In 100 ischaemic stroke patients, raised serum total cholesterol was seen in 42, triglyceride in 04, LDL-cholesterol in 05 and VLDL-cholesterol in 07 patients. Serum HDL-cholesterol was below the normal reference in 31 cases. On the other hand, serum total cholesterol and triglycerides was raised in 05 patients each, LDL-cholesterol in 09 and VLDL-cholesterol in 03 patients of haemorrhagic stroke. Serum HDL-cholesterol was below normal in 04 patients of haemorrhagic stroke. On comparison, there were significantly greater number of patients with raised serum cholesterol and low HDL-cholesterol in ischaemic stroke than haemorrhagic stroke (p < 0.05). No statistical significance was found on comparing serum values of ischaemic and haemorrhagic stroke for triglycerides, LDL-cholesterol and VLDL-cholesterol. Conclusion: Ischaemic stroke patients had high serum total cholesterol and lower HDL-cholesterol levels as compared to

  10. Gender difference in relationship between serum ferritin and 25-hydroxyvitamin D in Korean adults.

    Directory of Open Access Journals (Sweden)

    Jeong Min Seong

    Full Text Available The present study was conducted to assess the gender difference in the relationship between serum ferritin and 25-hydroxyvitamin D [25(OHD] in Korean adults.A total of 5,147 adults (2,162 men, 1,563 premenopausal women, and 1,422 postmenopausal women aged ≥ 20 years from the Korean National Health and Nutrition Examination Survey (KNHANES data (2012 were analyzed. A covariance test adjusted for covariates was performed for serum ferritin levels in relation to vitamin D status (vitamin D deficiency, 25(OHD < 10.0 ng/mL; vitamin D insufficiency, 25(OHD ≥ 10.0, < 20.0 ng/mL; vitamin D sufficiency, 25(OHD ≥ 20.0 ng/mL.The key study results were as follows: First, in men, in terms of serum ferritin levels by serum 25(OHD level after adjusting for age, smoking, alcohol drinking, regular exercise, SBP, DBP, WM. TC, TGs, HDL-C, FPG, Hb, Hct, MCV, and Fe, serum ferritin levels were inversely increased with the increasing of serum 25(OHD level (P = 0.012. Second, in premenopausal women, after adjusting for related variables, serum ferritin levels were increased with the increasing of serum 25(OHD level (P = 0.003. Third, in postmenopausal women, after adjusting for related variables, serum ferritin levels were not significantly increased with the increasing of serum 25(OHD level (P = 0.456.Serum 25(OHD level was inversely associated with the serum ferritin levels in men, but was positively associated with the serum ferritin levels in premenopausal women, and was not associated with the serum ferritin levels in postmenopausal women.

  11. The effect of steroidal contraceptives on liver enzymes and serum ...

    African Journals Online (AJOL)

    This study assessed the influence of steroidal contraceptives on liver enzymes and serum total protein using 48 adult female rats in four groups -A as control and B, C and D as tests. The animals were further divided into two subgroups - treatment (A1 - D1; n=6 each) and reversal (A2 - D2; n=6 each). Groups A1&A2 ...

  12. Assessment of Serum Vitamin D in Patients with Bronchial Asthma

    Directory of Open Access Journals (Sweden)

    Hisham E. Abd El Aaty

    2015-01-01

    Conclusions: Vitamin D deficiency was highly prevalent in asthmatic patients, there was a strong correlation between asthma severity and 25(OH vitamin D concentrations and there was a direct and a positive significant correlation between vitamin D levels and pulmonary function tests in asthmatic patients, so the measurement of serum vitamin D levels in patients with bronchial asthma is very useful.

  13. A solid-phase-radioimmunoassay for total serum thyroxine

    International Nuclear Information System (INIS)

    Moedder, G.; Sokolowski, G.

    1978-01-01

    A new solid phase radioimmunoassay for total serum thyroxine was evaluated over a longer time under clinical routine conditions and compared with an established test system. The results show up that the T 4 values are precise, reliable and reproducible, the is incomplicate to handle and well suitable for semiautomatic pipetting systems. (orig.) 891 MG [de

  14. Effectiveness and cost-effectiveness of serum B-type natriuretic peptide testing and monitoring in patients with heart failure in primary and secondary care: an evidence synthesis, cohort study and cost-effectiveness model.

    Science.gov (United States)

    Pufulete, Maria; Maishman, Rachel; Dabner, Lucy; Mohiuddin, Syed; Hollingworth, William; Rogers, Chris A; Higgins, Julian; Dayer, Mark; Macleod, John; Purdy, Sarah; McDonagh, Theresa; Nightingale, Angus; Williams, Rachael; Reeves, Barnaby C

    2017-08-01

    Heart failure (HF) affects around 500,000 people in the UK. HF medications are frequently underprescribed and B-type natriuretic peptide (BNP)-guided therapy may help to optimise treatment. To evaluate the clinical effectiveness and cost-effectiveness of BNP-guided therapy compared with symptom-guided therapy in HF patients. Systematic review, cohort study and cost-effectiveness model. A literature review and usual care in the NHS. (a) HF patients in randomised controlled trials (RCTs) of BNP-guided therapy; and (b) patients having usual care for HF in the NHS. Systematic review : BNP-guided therapy or symptom-guided therapy in primary or secondary care. Cohort study : BNP monitored (≥ 6 months' follow-up and three or more BNP tests and two or more tests per year), BNP tested (≥ 1 tests but not BNP monitored) or never tested. Cost-effectiveness model : BNP-guided therapy in specialist clinics. Mortality, hospital admission (all cause and HF related) and adverse events; and quality-adjusted life-years (QALYs) for the cost-effectiveness model. Systematic review : Individual participant or aggregate data from eligible RCTs. Cohort study : The Clinical Practice Research Datalink, Hospital Episode Statistics and National Heart Failure Audit (NHFA). A systematic literature search (five databases, trial registries, grey literature and reference lists of publications) for published and unpublished RCTs. Five RCTs contributed individual participant data (IPD) and eight RCTs contributed aggregate data (1536 participants were randomised to BNP-guided therapy and 1538 participants were randomised to symptom-guided therapy). For all-cause mortality, the hazard ratio (HR) for BNP-guided therapy was 0.87 [95% confidence interval (CI) 0.73 to 1.04]. Patients who were aged Chris A Rogers' and Maria Pufulete's time contributing to the study. Syed Mohiuddin's time is supported by the NIHR Collaboration for Leadership in Applied Health Research and Care West at University

  15. Overcoming the inhibitory effect of serum on lipofection by increasing the charge ratio of cationic liposome to DNA.

    Science.gov (United States)

    Yang, J P; Huang, L

    1997-09-01

    Since cationic liposome was first developed as a lipofection reagent, a drawback has been noted in that the efficiency of lipofection decreases dramatically after addition of serum to the lipofection medium. This drawback hampers the application of cationic liposome for systematic delivery of genes. In the present studies, we found that the effect of serum on DC-chol liposome-mediated lipofection is dependent on the charge ratio of liposome to DNA. Serum inhibited lipofection activity of the lipoplex at low charge ratios, whereas it enhanced the lipofection activity at high charge ratios. This phenomenon was observed using DOTAP/DOPE but not lipofectamine. Measurement of cellular association of DNA showed that serum could reduce the binding of lipoplex to cells at all tested charge ratios, i.e. 0-10.6. Removal of negatively charged proteins from serum by DEAE Sephacel column abolished the inhibitory effect of serum on lipofection. The fraction contained only negatively charged serum proteins which strongly inhibited lipofection at low charge ratios but not at higher charge ratios. Furthermore, preincubation of serum with positively charged polylysine, which neutralized negatively charged serum proteins, eliminated the inhibitory effect of serum on lipofection. In summary, inactivation of cationic liposome by serum is due to negatively charged serum proteins and it can be overcome by increasing charge ratio of cationic liposome-DNA lipoplexes or by neutralizing the serum with polylysine.

  16. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  17. Serum Lipid Profile: Fasting or Non-fasting?

    OpenAIRE

    Nigam, P. K.

    2010-01-01

    Serum lipid profile has now become almost a routine test. It is usually done in fasting state due to certain limitations in non-fasting serum sample. In the recent past efforts have been made to simplify blood sampling by replacing fasting lipid profile with non-fasting lipid profile. However, fasting specimen is preferred if cardiovascular risk assessment is based on total cholesterol, LDL cholesterol or non-HDL cholesterol. A lot has yet to be done in this area. Till then we have to believe...

  18. Radioimmunoassay of serum β2-microglobulin in donor's blood

    International Nuclear Information System (INIS)

    Yin Shihua; Song Shiyun; Li Kelin; Chen Guanglian; Liu Fengmin

    1993-01-01

    Serum β 2 -microglobulin (β 2 -MG) was tested by radioimmunoassay in 149 donors' and 54 healthy volunteers' blood. The results were 203 +- 33.0 nmol/l and 176 +- 26.2 nmol/l, respectively. There was significant difference statistically between them (P 2 -MG content. In order to increase the quality of donated blood and to keep the health of blood donor, it is suggested that the high content of serum β 2 -MG is the indicator of too frequent blood donating. The results also showed that the content of β 2 -MG in donor's blood is not a normal reference value

  19. Increased serum potassium affects renal outcomes

    DEFF Research Database (Denmark)

    Miao, Y; Dobre, D; Heerspink, H J Lambers

    2011-01-01

    To assess the effect of an angiotensin receptor blocker (ARB) on serum potassium and the effect of a serum potassium change on renal outcomes in patients with type 2 diabetes and nephropathy.......To assess the effect of an angiotensin receptor blocker (ARB) on serum potassium and the effect of a serum potassium change on renal outcomes in patients with type 2 diabetes and nephropathy....

  20. Interaction of Citrinin with Human Serum Albumin

    Directory of Open Access Journals (Sweden)

    Miklós Poór

    2015-12-01

    Full Text Available Citrinin (CIT is a mycotoxin produced by several Aspergillus, Penicillium, and Monascus species. CIT occurs worldwide in different foods and drinks and causes health problems for humans and animals. Human serum albumin (HSA is the most abundant plasma protein in human circulation. Albumin forms stable complexes with many drugs and xenobiotics; therefore, HSA commonly plays important role in the pharmacokinetics or toxicokinetics of numerous compounds. However, the interaction of CIT with HSA is poorly characterized yet. In this study, the complex formation of CIT with HSA was investigated using fluorescence spectroscopy and ultrafiltration techniques. For the deeper understanding of the interaction, thermodynamic, and molecular modeling studies were performed as well. Our results suggest that CIT forms stable complex with HSA (logK ~ 5.3 and its primary binding site is located in subdomain IIA (Sudlow’s Site I. In vitro cell experiments also recommend that CIT-HSA interaction may have biological relevance. Finally, the complex formations of CIT with bovine, porcine, and rat serum albumin were investigated, in order to test the potential species differences of CIT-albumin interactions.

  1. Al cation induces aggregation of serum proteins.

    Science.gov (United States)

    Chanphai, P; Kreplak, L; Tajmir-Riahi, H A

    2017-07-15

    Al cation is known to induce protein fibrillation and causes several neurodegenerative disorders. We report the spectroscopic, thermodynamic analysis and AFM imaging for the Al cation binding process with human serum albumin (HSA), bovine serum albumin (BSA) and milk beta-lactoglobulin (b-LG) in aqueous solution at physiological pH. Hydrophobicity played a major role in Al-protein interactions with more hydrophobic b-LG forming stronger Al-protein complexes. Thermodynamic parameters ΔS, ΔH and ΔG showed Al-protein bindings occur via hydrophobic and H-bonding contacts for b-LG, while van der Waals and H-bonding interactions prevail in HSA and BSA adducts. AFM clearly indicated that aluminum cations are able to force BSA and b-LG into larger or more robust aggregates than HSA, with HSA 4±0.2 (SE, n=801) proteins per aggregate, for BSA 17±2 (SE, n=148), and for b-LG 12±3 (SE, n=151). Thioflavin T test showed no major protein fibrillation in the presence of Al cation. Al complexation induced major alterations of protein conformations with the order of perturbations b-LG>BSA>HSA. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The clinical value of serum PSA and PAP determinations in prostate cancer patients

    International Nuclear Information System (INIS)

    Zeng Lei; Yu Renbo; Du Guowei; Pang Baozhong

    2001-01-01

    Objective: To investigate the clinical value of serum PSA and PAP determinations in diagnosis of prostate cancer patients. Methods: The serum PSA and PAP levels of 98 prostate cancer patients, 45 prostate benign disease patients and 40 normal subjects were tested by IRMA. Results: The serum PSA and PAP levels of prostate cancer patients were significantly higher than those in prostate benign disease patients and normal controls (P < 0.01). The diagnostic sensitivity and specificity of serum PSA for prostate cancer were 93.9% and 93.3% respectively. The diagnostic sensitivity and specificity of serum PAP for prostate cancer were 71.4% and 91.1% respectively. Conclusion: The determination of serum PSA and PAP was of high clinical value for diagnosis of early prostate cancer. It could be used as an important reference parameter for the clinical staging, follow-up of treatment result and prediction of prognosis

  3. Relationship Between Serum Adiponectin and Urinary Albumin Excretion Rate in Patients with Diabetes Nephropathy

    International Nuclear Information System (INIS)

    Duan Yongqiang; Yu Hui; Wang Zuobing

    2010-01-01

    To explore the relationship between the levels of serum adiponectin and urinary albumin excretion rate in patients with type 2 diabetes nephropathy, the serum levels of adiponectin and the levels of urinary albumin excretion rate in diabetes patients before and after treatment with pioglitazone were tested by ELISA and automatic biochemical analyzer respectively. The results showed that the serum levels of adiponectin in DM and DN group were lower than that of normal controls(P<0.01), but they gradually increased with progression (P<0.01). The serum adiponectin level was positively correlated with urinary albumin excretion rate (r= 0.284, P<0.05). The urinary albumin level decreased (P<0.01) and the serum levels of adiponectin increased after treatment with pioglitazone in DN group. The serum levels of adiponectin and urinary albumin excretion rate may play important role in the indication of treatment of diabetes. (authors)

  4. Serum TBG and T4 concentration in non-thyroidal diseases

    International Nuclear Information System (INIS)

    Sasaki, Y.; Tobari, C.; Sekita, N.; Onodera, Y.; Asazu, M.; Someya, K.

    1983-01-01

    Routinely available radioassay kits have recently enabled the measurement of serum concentrations of thyroxine binding globulin (TBG) and thyroxine (T 4 ), both total (TT 4 ) and free (FT 4 ) in various disease conditions. Serum TBG and T 4 level were measured in variety of non-thyroidal diseases, of which significance was evaluated in comparison with that in thyroidal diseases. Abnormal serum TBG concentrations in various non-thyroidal diseases and pregnancy result in abnormal serum TT 4 levels, which may cause difficulty in differentiation of these conditions from hyper- or hypothyroidal states. Serum FT 4 levels give better indicator than TT 4 , though the difference among RIA kits are considerably large. However, measurement of serum FT 4 levels alone is not sufficient to distinguish non-thyroidal disease from thyroidal diseases with abnormal thyroidal function. The differentiation has to be based on the combination of clinical findings and results of multiple thyroidal function tests

  5. Intraerythrocyte and serum electrolytes in diabetic patients hypertension

    International Nuclear Information System (INIS)

    Yasmin, F.; Haleem, D.J.; Haleem, M. A.

    2006-01-01

    To determine the serum and intraerythrocyte concentrations of vasoactive ions in patients of diabetes mellitus of either gender with hypertension. The study was conducted on 48 volunteers. Out of 48, 24(12 men and 12 women) were hypertensive patients with diabetes mellitus. Remaining (12 men and 12 women) were normal healthy subjects. Biochemical estimations were done by flame photometry and spectrophotometry. Data were analyzed by Two-way ANOVA followed by Newman-Keuls test. A decrease in serum concentrations of sodium, calcium, magnesium, phosphorus, chloride and intraerythrocyte potassium and an increase in the levels of glucose, haematocrit and intraerythrocyte sodium was observed in both male and female patients with diabetes mellitus and hypertension. No significant changes were observed in serum potassium levels. The results suggest that dysregulations of electrolyte balance caused by hyperinsulinemia or altered glucose metabolism may lead to hypertension. (author)

  6. Prostate-specific antigen superior serum marker for prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, J A; Allen, M A; Keane, T; Duffy, J J

    1987-05-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM/sup R/) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable.

  7. Prostate-specific antigen superior serum marker for prostatic carcinoma

    International Nuclear Information System (INIS)

    Heaney, J.A.; Allen, M.A.; Keane, T.; Duffy, J.J.

    1987-01-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM R ) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable. (author)

  8. Carriers of the TCF7L2 rs7903146 TT genotype have elevated levels of plasma glucose, serum proinsulin and plasma gastric inhibitory polypeptide (GIP) during a meal test

    DEFF Research Database (Denmark)

    Gjesing, A P; Kjems, L L; Vestmar, M A

    2011-01-01

    , proinsulin, insulin, C-peptide, glucagon, glucagon-like peptide-1 (GLP-1), glucagon-like peptide-2 (GLP-2) and gastric inhibitory polypeptide (GIP) among individuals carrying the high-risk rs7903146 TT genotype and low-risk CC genotype following a meal test. Methods A meal challenge was performed in 31......, 45, 60, 75, 90, 105, 120, 135, 150, 180, 210, and 240 min after ingestion of a standardised breakfast meal. Results An elevated incremental AUC for plasma glucose was observed among TT genotype carriers (CC carriers 21.8¿±¿101.9 mmol/l¿×¿min vs TT carriers 97.9¿±¿89.2 mmol/l¿×¿min, p¿=¿0.001). TT...

  9. A Novel Panel of Serum Biomarkers for MPM Diagnosis

    Directory of Open Access Journals (Sweden)

    A. Bonotti

    2017-01-01

    Full Text Available Exposure to asbestos is the main cause of malignant pleural mesothelioma (MPM, a highly aggressive cancer of the pleura. Since the only tools for early detection are based on radiological tests, some authors focused on serum markers (i.e., mesothelin. The aim of this study was the evaluation of new serum biomarkers to be used individually or in combination, in order to improve the outcome of patients whose disease would be diagnosed at an earlier stage. Serum and plasma were available from 43 subjects previously exposed to asbestos and 27 MPM patients, all being epithelioid type. All the new markers found differentially expressed in MPM and healthy subjects, by proteomic and genomic approaches, have been validated in the serum by the use of specific ELISA. The combined approach, using tools of genomics and proteomics, is found to be highly innovative for this type of disease and led to the identification of new serum markers in the diagnosis of MPM. These results, if confirmed in a larger series, may have a strong impact in this area, because early detection of this cancer in people at high risk could significantly improve the course of the disease and the clinical approach to an individualized therapy.

  10. Increased serum cortisol binding in chronic active hepatitis

    International Nuclear Information System (INIS)

    Orbach, O.; Schussler, G.C.

    1989-01-01

    A high serum cortisol concentration, apparently due to increased cortisol-binding globulin (CBG), was found in a patient (index case) with chronic active hepatitis (CAH). We therefore performed further studies to determine whether increased cortisol binding is generally associated with CAH. Serum samples were obtained from 15 hospitalized patients with long-term liver function test elevations but no evidence of cirrhosis, 15 normal subjects without a history of hepatitis, four healthy pregnant women, and 10 alcoholic patients with stigmata of cirrhosis. Serum cortisol binding was measured by an adaptation of a previously described charcoal uptake method. Thyroxine-binding globulin (TBG) and sex hormone-binding globulin were determined by radioimmunoassays. Charcoal uptake of 125I cortisol from sera of normal subjects and additional patients with CAH revealed that increased serum cortisol binding by a saturable site, presumably CBG, was associated with CAH. Cortisol binding was significantly correlated with immunoassayable TBG, suggesting that in CAH, similar mechanisms may be responsible for increasing the serum concentrations of CBG and TBG

  11. Serum bile acid concentrations in dairy cattle with hepatic lipidosis.

    Science.gov (United States)

    Garry, F B; Fettman, M J; Curtis, C R; Smith, J A

    1994-01-01

    This study was designed to evaluate serum bile acid measurements as indicatory, of liver function and/or hepatic fat infiltration in dairy cattle. Serum bile acid concentrations were measured in healthy dairy cattle at different stages of lactation after fasting or feeding. Bile acid concentrations were compared with liver fat content and sulfobromophthalein (BSP) half-life (T 1/2). Serum bile acid concentrations were higher in cows in early lactation and with higher daily milk production. Compared with prefasting values, bile acid concentrations were decreased at 8, 14, and 24 hours of fasting. Blood samples from fed cows at 1- to 2-hour intervals had wide and inconsistent variations in bile acid concentration. Because serum bile acids correlated well with BSP T 1/2, it is suggested that both measurements evaluate a similar aspect of liver function. Neither bile acids nor BSP T 1/2 correlated with differences in liver fat content among cows. Because of large variability in serum bile acid concentrations in fed cows and the lack of correlation of measured values with liver fat content, bile acid determinations do not appear useful for showing changes in hepatic function in fed cows with subclinical hepatic lipidosis nor serve as a screening test for this condition.

  12. Low serum myeloperoxidase in autistic children with gastrointestinal disease

    Directory of Open Access Journals (Sweden)

    Anthony J Russo

    2009-08-01

    Full Text Available Anthony J Russo1, Arthur Krigsman2, Bryan Jepson2, Andy Wakefield21Research Director, Health Research Institute/Pfeiffer Treatment Center, Warrenville, IL, USA; 2Thoughtful House Center for Children, Austin, TX, USAAim: To assess serum myeloperoxidase (MPO levels in autistic children with severe gastrointestinal (GI disease and to test the hypothesis that there is an association between serum MPO concentration and inflammatory GI disease, including antineutrophil cytoplasmic antibodies (ANCA, previously seen in a subgroup of autistic children.Subjects and methods: Serum from 40 autistic children with chronic digestive disease (most with ileo-colonic lymphoid nodular hyperplasia (LNH and inflammation of the colorectum, small bowel and/or stomach, and 48 controls (12 age-matched autistic children with no GI disease, 20 age-matched children without autism or GI disease, and 16 nonautistic individuals with no family history of autism were tested using enzyme-linked immunosorbent assays designed to quantitate serum MPO levels. MPO serum concentration of autistic children with GI disease was compared to GI disease severity (including LNH and erythema and presence of ANCA.Results: We found that a significant number of autistic children with chronic digestive disease had low serum levels of MPO. However, there was no significant relationship between these levels and severity of GI disease, including the presence of ANCA.Discussion: These results suggest a relationship between low MPO levels and GI disease seen in a subpopulation of autism spectrum disorders individuals. MPO concentration may therefore be a useful biomarker for GI disease in this group of autistic children.Keywords: autism spectrum disorders, autism, myeloperoxidase, GI disease, oxidative stress

  13. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  14. Diagnostic evaluation of serum FSH and LH in primary amenorrhea by radioimmunoassay

    International Nuclear Information System (INIS)

    Hong, I.S.; Kim, G.E.; Yoo, H.S.; Lee, J.T.; Park, C.Y.

    1980-01-01

    The usefulness of single, random measurements of serum FSH and LH in the diagnosis of primary amenorrhea by radioimmunoassay was investigated. The 16 patients were divided into 3 groups by the level of serum FSH and LH. The first group with increased level of serum FSH and LH is five patients, all of these are related to the acquired or congenital abnormality of the ovary. Further studies indicated include buccal smear, chromosome analysis, gynecography and laparoscopy. The second group with normal serum FSH and LH is nine patients, four patients of these are related to the developmental anomaly of the Mullerian duct and five patients are undetermined origin. Further studies indicated include laparoscopy and gynecography. The third group with decreased serum FSH and normal or decreased serum LH is two patients, one of these is related to the pituitary function, isolated FSH deficiency, the other is undetermined origin. Further studies indicated include the pituitary function test, LH-RH stimulation test, skull radiography. Determination of serum FSH and LH levels does not permit a specific etiologic diagnosis of promary amenorrhea. However the serum levels of FSH and LH can be used to differentiate the principal area of the investigation and can be of assistance in choosing more specific testing procedures. (Author)

  15. In vitro demonstration of anti-lipogenic activity in serum from obese rats

    International Nuclear Information System (INIS)

    Harris, R.B.S.; Martin, R.J.

    1986-01-01

    Studies with parabiosed rats provide evidence for a humoral factor, originating in obese animals, that specifically inhibits adipose lipogenesis. A bioassay was developed that allows serum from obese rats to be tested for this factor in vitro. Adipocytes are isolated from epididymal fat of 250g Sprague-Dawley rats. The cells are preincubated at 37 0 C for 1 or 12 hrs, in TC199 media containing 1.1 mg/ml glucose, 0.1 M Hepes and 2% serum. Following preincubation, the cells are washed 3 times and resuspended in serum-free media. Aliquots of cells are tested for metabolic activity in a subsequent 2 hour radiolabelled incubation in serum-free media with the addition of 0.5 μCi/ml U- 14 C-glucose. Basal, insulin (100 μU/ml) and norepinephrine (0.1 μg/ml) stimulated rates of glucose oxidation and conversion to triglyceride fatty acids are measured. Using serum from ad libitum fed rats as control, preincubation with serum from obese rats (20 days at 2 x normal intake) depressed basal and insulin stimulated glucose oxidation, and basal fatty acid synthesis. Serum from obese parabiotic rats and parabiotic partners of obese rats depressed basal fatty acid synthesis. This assay allows us to test serum for anti-lipogenic activity and may be used to identify the factor responsible for this activity in obese animals

  16. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  17. Analysis of trace elements in serum from human eating irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi; Chen Shijie; Gao Sumei

    1987-01-01

    A method of trace element analysis by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AEC) in serum from human eating food preserved by irradiation is described. Trace element analysis in human serum is one of the research projects concerning the wholesomeness. 78 serum samples of the human eating food preserved by irradiation were collected. After ashing and solving ICP-AES analysis of serum is performed for detecting 12 trace elements in specimen solution. The detection limitations are in the range of 10 -2 - 10 -3 ppm for differemt elements. The recoveries of elements are over 73%. Concentrations of 12 trace elements in 78 human serum has been calculated with F and t tests at PDP 11/70 computer and it was concluded that there is no significant difference between testing group and control group

  18. Pancreatic Exocrine Function Testing

    OpenAIRE

    Berk, J. Edward

    1982-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and par...

  19. Serum Antibody Biomarkers for ASD

    Science.gov (United States)

    2015-10-01

    typically developing control. US, unaffected sibling control. 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a...typically developing (TD) children (e.g., Warren et al., 1990; Singh, 2009). The goal of this study is to identify a serum antibody biomarker for ASD using...50% less IgG1 antibody in ASD boys vs . TD boys (p=0.0096). The level of ASD1 binding to the AM group was the same as to the ASD boys. These data

  20. Correlation Between Preoperative Serum Carcinoembryonic Antigen Levels and Expression on Pancreatic and Rectal Cancer Tissue

    Directory of Open Access Journals (Sweden)

    LSF Boogerd

    2017-05-01

    Full Text Available Carcinoembryonic antigen (CEA–targeted imaging and therapeutic agents are being tested in clinical trials. If CEA overexpression in malignant tissue corresponds with elevated serum CEA, serum CEA could assist in selecting patients who may benefit from CEA-targeted agents. This study aims to assess the relationship between serum CEA and CEA expression in pancreatic (n = 20 and rectal cancer tissues (n = 35 using histopathology. According to local laboratory standards, a serum CEA >3 ng/mL was considered elevated. In pancreatic cancer patients a significant correlation between serum CEA and percentage of CEA-expressing tumor cells was observed ( P  = .04, ρ = .47. All 6 patients with homogeneous CEA expression in the tumor had a serum CEA >3 ng/mL. Most rectal cancer tissues (32/35 showed homogeneous CEA expression, independent of serum CEA levels. This study suggests that selection of pancreatic cancer patients for CEA-targeted agents via serum CEA appears adequate. For selection of rectal cancer patients, serum CEA levels are not informative.

  1. Serum nitric oxide metabolites and disease activity in patients with systemic sclerosis.

    Science.gov (United States)

    Mok, Mo Yin; Fung, Peter Chin Wah; Ooi, Clara; Tse, Hung Fat; Wong, Yik; Lam, Yui Ming; Wong, Woon Sing; Lau, Chak Sing

    2008-03-01

    There is no surrogate marker in serum for defining disease activity in scleroderma (SSc). Nitric oxide (NO), which regulates vasodilation and possesses pro-inflammatory actions, has been implicated in the pathogenesis of SSc. We compared serum NO(x) (total nitrate and nitrite) level in SSc patients to healthy controls and evaluated its correlation with detailed symptomatology and scoring systems for various organ involvement. Symptoms and physical findings that suggested disease activity in regard to various organs were documented. Lung function test, high-resolution computed tomographic (HRCT) scan of thorax and echocardiography were performed. Serum NO(x) was measured by chemiluminescence. Serum NO(x) levels in SSc (n = 43) were significantly higher (72.4 +/- 47.8 microM) than age- and sex-matched controls (n = 41; 37.1 +/- 13.5 microM; p n = 9; OR 145.3, p = 0.01) were predictive factors for elevated serum NO(x). Prednisolone use was associated with lower serum NO(x) level (OR 0.06, p = 0.04). Elevated PAP of increasing severity was found to be associated with higher level of serum NO(x) (p = 0.004 by trend). Serum NO(x) in SSc patients were elevated compared to healthy controls. Serum NO(x) level was determined by multiple factors including age, prednisolone use, and elevated PAP.

  2. Serum Glutamate Is a Predictor for the Diagnosis of Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gheyath Al Gawwam

    2017-01-01

    Full Text Available One neurotransmitter, glutamate, has been implicated in the autoimmune demyelination seen in multiple sclerosis (MS. Glutamate is present in many tissues in the body, so consideration should be given to whether the serum level of glutamate is likely well correlated with the activity of the disease. This research aimed to compare the serum glutamate levels from patients diagnosed with MS with those from an age-matched control population. A review of this data could shed light upon whether the serum testing of glutamate using Enzyme-Linked Immunosorbent Assay (ELISA is a reliable indicator of MS activity. Serum samples were obtained from 55 patients with different patterns of MS and from 25 healthy adults as a control group. The ELISA technique was used to determine the glutamate levels in the serum samples. The mean serum glutamate level for patients with MS was 1.318±0.543 nmol/ml and that of the controls was 0.873±0.341 nmol/ml. The serum glutamate levels showed an area under the curve via the receiver operating characteristics (ROC of 0.738, which was significant (p value = 0.001. The present study is the first to establish a strong connection between the serum glutamate levels and MS patients, where there was statistically significant elevation of serum glutamate in MS patients; hence this elevation might be used as a monitor to help in the diagnosis of MS patients.

  3. Increased serum erythropoietin activity in rats following intrarenal injection of nickel subsulfide

    International Nuclear Information System (INIS)

    Hopfer, S.M.; Sunderman, F.W. Jr.; Fredrickson, T.N.; Morse, E.E.

    1979-01-01

    To investigate the pathopysiologic mechanisms of nickel-induced erythocytosis, serum erythropoietin activities were measured in (a) pooled serum from rats at 2 wk after intrarenal injection of αNi 3 S 2 (5 mg/rat), and (b) pooled serum from control rats at 2 wk after intrarenal injection of sterile NaCl vehicle (0.4 ml/rat). A sensitive erythropoietin bioassay was employed, which entailed repetitive administration of test serums to post-hypoxic polycythemic mice in divided doses (12 s.c. injections of 0.5 ml of serum at 6 h intervals for 3 da; total dose = 6 ml of serum/mouse). The erythropoietin detection limit was approx. = 20 I.U./liter of serum. In mice which received pooled serum from αNi 3 S 2 -treated rats, erythrocyte 59 Fe-uptake averaged 28% (S.D. +- 5) (vs 3.7 +- 1.1% in control rats; P 3 S 2 -treated rats averaged 130 I.U./liter (S.D. +- 18) (vs 27 +- 6 I.U./liter in control rats; P 3 S 2 is mediated by increased serum erythropoietin activity

  4. Body mass index and serum lipid levels

    Directory of Open Access Journals (Sweden)

    Pedro Javier Navarrete Mejía

    2016-02-01

    Full Text Available Objective: To identify the association between the body mass index (BMI and serum lipid levels in adult people. Material and Methods: Observational, transversal and retrospective study. Non experimental investigation design. The population was conformed for people treated in private health centers in Metropolitan Lima. The evaluations of the BMI and the laboratorial tests to know the seric concentration of lipids were taken between October 2014 and October 2015. It was determined the association between the BMI and the seric lipid levels using the Chi2 test. People with comorbidity that could modify the seric levels of lipids were excluded. Results: 39.7% of people studied were male and 60.3% were female. The average age was 34.2 years old. 40.7% (1227/3016 of population were obese and overweight. The results show a higher level of obesity or overweight in male people over female (54.6% and 33% respectively. 19.7% (594/3016 of the tested people presented high triglycerides seric levels. 27.9% (841/3016 presented high cholesterol levels and 38.8% (1146/3016 presented low cHDL levels. The cLDL levels and cVLDL levels were similar in both groups (male and female. Conclusions: The investigation determined the significant statistical association between the BMI and triglycerides (p < 0.05, cholesterol (p < 0.05 and cHDL (p < 0.05.

  5. Evaluation of Serum Anti-Cardiolipin Antibody Titer in Patients with Chronic Periodontitis

    Directory of Open Access Journals (Sweden)

    SH. Faghihi

    2009-06-01

    Full Text Available Objective: Evidence shows periodontally infected patients may be at a higher risk of thrombotic accidents and adverse pregnancy outcomes, via induced systemic inflammatory mediators’ production. Some authors have concluded that increase in systemic inflammatorymarkers occurs together with increase in serum levels of auto antibodies including anti-cardiolipin antibody (ACLA. The aim of the present study was to compare the serum ACLA level between patients with chronic periodontitis (CP and periodontally healthycontrols.Materials and Methods: Fifty-one patients with moderate and advanced CP (test groupand 49 periodontally healthy people (control group were included in the study. Clinical parameters including PI, GBI, PPD and CAL were measured. Serum ACLA level of all cases was measured using ELISA method. The data were analyzed with Student t-test and Pearson's correlation.Results: A significant difference existed in serum ACLA level between test and control groups (P=0.001. All cases in both test and control groups, however, showed a normal range of serum ACLA level.A positive correlation also existed between serum ACLA level and periodontal parameters including CAL, PPD, GBI and PI (P<0.001, P<.001, P=0.001 and P=0.002, respectively.In addition, a moderately positive correlation (P=0.003 between age and ACLA level wasfound.Conclusion: An increased serum ACLA level might be associated with chronic periodontitis.

  6. Serum Albumin Levels and Economic Status in Japanese Older Adults.

    Directory of Open Access Journals (Sweden)

    Asami Ota

    Full Text Available Low serum albumin levels are associated with aging and medical conditions such as cancer, liver dysfunction, inflammation, and malnutrition and might be an independent predictor of long-term mortality in healthy older populations. We tested the hypothesis that economic status is associated with serum albumin levels and explained by nutritional and health status in Japanese older adults.We performed a cross-sectional analysis using data from the Japan Gerontological Evaluation study (JAGES. The study participants were 6528 functionally independent residents (3189 men and 3339 women aged ≥65 years living in four municipalities in Aichi prefecture. We used household income as an indicator of economic status. Multiple linear regression was used to compare serum albumin levels in relation to household income, which was classified as low, middle, and high. Additionally, mediation by nutritional and health-related factors was analyzed in multivariable models.With the middle-income group as reference, participants with low incomes had a significantly lower serum albumin level, even after adjustment for sex, age, residential area, education, marital status, and household structure. The estimated mean difference was -0.17 g/L (95% confidence interval, -0.33 to -0.01 g/L. The relation between serum albumin level and low income became statistically insignificant when "body mass index", "consumption of meat or fish", "self-rated health", "presence of medical conditions", "hyperlipidemia", or "respiratory disease "was included in the model.Serum albumin levels were lower in Japanese older adults with low economic status. The decrease in albumin levels appears to be mediated by nutrition and health-related factors with low household incomes. Future studies are needed to reveal the existence of other pathways.

  7. Studies on the direct radioimmunological determination of triiodothyronine in serum

    International Nuclear Information System (INIS)

    Meinhold, H.; Wenzel, K.W.

    1974-01-01

    The production of highly specific antisera for T 3 and the development of a sensitive radioimmunological procedure for the direct measurement of T 3 in serum is described. Anti-T 3 sera were produced by immunizing rabbits with conjugates of T 3 and bovine albumin, human albumin, and ovalbumin. The various antisera produced showed very little variance in quality and could be used for the direct radioimmunological determination of serum-T 3 with final dilutions between 1:60,000 and 1:300,000. Binding of T 3 to thyroid-hormone-binding serum proteins was inhibited by 8-anilinonaphthalene-1-sulfonic acid. This compound showed better inhibition properties than merthiolate and sodium salicylate. The separation of free and bound hormone was performed by the double antibody technique. The separation by dextran-coated charcoal and ion-exchange resin leads to a decrease of the antibody-bound activity. The validation of the method used was tested by serial dilutions of sera, recovery experiments, and by comparing the serum-T 3 values measured in ethanol extracts with those values obtained by the direct measurement in unextracted serum. The lower limit of detection was approximately 0.18 nmol/l serum. The variation coefficient for the intraassay reproducibility was between 4.3 and 6.1%, for the interassay reproducibility between 7.7 and 13.9%. Measured mean T 3 concentrations for various thyroid states were as follows: Normals: 1.77 nmol/l (1.15 μg/l), normal females on contraceptives: 2.03 nmol/l (1.32 μg/l), pregnants: 2.73 nmol/l (1.78 μg/l), hyperthyroidism: 6.30 nmol/l (4.10 μg/l), T 3 -toxicosis: 3.69 nmol/l (2.40 μg/l). In hypothyroidism T 3 ranged from [de

  8. Serum homocyst(e)ine levels in women with preeclampsia.

    Science.gov (United States)

    Mayerhofer, K; Hefler, L; Zeisler, H; Tempfer, C; Bodner, K; Stöckler-Ipsiroglu, S; Mühl, A; Kaider, A; Schatten, C; Leodolter, S; Husslein, P; Kainz, C

    2000-03-24

    Endothelial dysfunction has been described as the final common pathophysiological pathway in the development of preeclampsia. Since it has been suggested that homocyst(e)ine damages endothelial cells, we measured serum homocyst(e)ine levels in women with preeclampsia and in healthy pregnant women in order to find a new prognostic parameter for women with preeclampsia. Forty-five women with preeclampsia and 45 healthy women with uncomplicated pregnancies, matched for age and parity, were entered into the study. Serum homocyst(e)ine levels were measured by gas chromatography-mass spectrometry analysis and correlated to clinical data. Logistic regression models were used to analyse the influence of serum homocyst(e)ine levels on the presence of preeclampsia versus healthy pregnant women and on the risk of premature termination of pregnancy due to preeclampsia. Median serum homocyst(e)ine levels in women with preeclampsia and healthy pregnant women were 14.2 (range 5.7-38.1) mumol/L and 15.1 (range 5.2-23.1) mumol/L, respectively (Mann-Whitney U-test, p = 0.8). In univariate logistic regression models, serum homocyst(e)ine levels had no significant influence on the odds of presenting with preeclampsia versus healthy pregnant women (univariate logistic regression model, p = 0.8) and on the odds of premature termination of pregnancy due to preeclampsia (univariate logistic regression model, p = 0.3). Serum homocyst(e)ine levels are not elevated in women with preeclampsia and are not associated with clinical outcome in women with preeclampsia.

  9. Serum Reactive Oxygen Metabolite Levels Predict Severe Exacerbations of Asthma

    Science.gov (United States)

    Nakamoto, Keitaro; Watanabe, Masato; Sada, Mitsuru; Inui, Toshiya; Nakamura, Masuo; Honda, Kojiro; Wada, Hiroo; Mikami, Yu; Matsuzaki, Hirotaka; Horie, Masafumi; Noguchi, Satoshi; Yamauchi, Yasuhiro; Koyama, Hikari; Kogane, Toshiyuki; Kohyama, Tadashi; Takizawa, Hajime

    2016-01-01

    Background and Purpose Bronchial asthma (BA) is a chronic airway disease characterized by airway hyperresponsiveness and remodeling, which are intimately linked to chronic airway inflammation. Reactive oxygen species (ROS) such as hydrogen peroxide are generated by inflammatory cells that are involved in the pathogenesis of BA. However, the role of ROS in the management of BA patients is not yet clear. We attempted to determine the role of ROS as a biomarker in the clinical setting of BA. Subjects and Methods We enrolled patients with BA from 2013 through 2015 and studied the degrees of asthma control, anti-asthma treatment, pulmonary function test results, fractional exhaled nitric oxide (FeNO), serum reactive oxygen metabolite (ROM) levels, and serum levels of interleukin (IL)-6 and IL-8. Results We recruited 110 patients with BA. Serum ROM levels correlated with white blood cell (WBC) count (rs = 0.273, p = 0.004), neutrophil count (rs = 0.235, p = 0.014), CRP (rs = 0.403, p < 0.001), and IL-6 (rs = 0.339, p < 0.001). Serum ROM levels and IL-8 and CRP levels negatively correlated with %FEV1 (rs = -0.240, p = 0.012, rs = -0.362, p < 0.001, rs = -0.197, p = 0.039, respectively). Serum ROM levels were significantly higher in patients who experienced severe exacerbation within 3 months than in patients who did not (339 [302–381] vs. 376 [352–414] CARR U, p < 0.025). Receiver-operating characteristics analysis showed that ROM levels correlated significantly with the occurrence of severe exacerbation (area under the curve: 0.699, 95% CI: 0.597–0.801, p = 0.025). Conclusions Serum levels of ROM were significantly associated with the degrees of airway obstruction, WBC counts, neutrophil counts, IL-6, and severe exacerbations. This biomarker may be useful in predicting severe exacerbations of BA. PMID:27776186

  10. Serum cortisol and BDNF in patients with major depression-effect of yoga.

    Science.gov (United States)

    Naveen, G H; Varambally, Shivarama; Thirthalli, Jagadisha; Rao, Mukund; Christopher, Rita; Gangadhar, B N

    2016-06-01

    Depression is associated with low serum Brain Derived Neurotrophic Factor (BDNF) and elevated levels of serum cortisol. Yoga practices have been associated with antidepressant effects, increase in serum BDNF, and reduction in serum cortisol. This study examined the association between serum BDNF and cortisol levels in drug-naïve patients with depression treated with antidepressants, yoga therapy, and both. Fifty-four drug-naïve consenting adult outpatients with Major Depression (32 males) received antidepressants only (n = 16), yoga therapy only (n = 19), or yoga with antidepressants (n = 19). Serum BDNF andcortisol levels were obtained before and after 3 months using a sandwich ELISA method. One-way ANOVA, Chi-square test, and Pearson's correlation tests were used for analysis. The groups were comparable at baseline on most parameters. Significant improvement in depression scores and serum BDNF levels, and reduction in serum cortisol in the yoga groups, have been described in previous reports. A significant negative correlation was observed between change in BDNF (pre-post) and cortisol (pre-post) levels in the yoga-only group (r = -0.59, p = 0.008). In conclusion, yoga may facilitate neuroplasticity through stress reduction in depressed patients. Further studies are needed to confirm the findings and delineate the pathways for these effects.

  11. An immunoradiometric assay for Helicobacter pylori urease B in serum

    International Nuclear Information System (INIS)

    Bai Yanyan; Wang Zhaoyue; Bai Xia; Ruan Changgen; Miao Jingcheng; Gu Guanbing

    2008-01-01

    Objective: The aim of this study was to establish and evaluate a novel immunoradiometric assay (IRMA) for detecting helicobacter pylori (HP) urease B (ureB) in serum. Methods: HP ureB was prepared by the DNA recombinant technique. Monoclonal antibodies against HP ureB were produced by hybridoma technique and were used to establish IRMA for detecting HP ureB. Fifty patients with chronic gastric diseases were recruited in this study, including 36 with gastric ulcer disease, 9 with chronic gastritis and 5 with gastric cancer. The IRMA was compared with rapid urease test (RUT), polymerase chain reaction (PCR) test and direct-ELISA test of serum anti-ureB antibody, using HP culture from gastric biopsy samples as a 'golden standard'. Results: The sensitivity and specificity of IRMA for HP ureB were 94.6% and 76.9%, respectively, with positive and negative predictive values being 92.1% and 83.3%. The sensitivity and specificity of RUT, PCR and serum anti-ureB antibody test were 94.6% and 23.1% , 66.8% and 84.6%, 86.5% and 38.5%, respectively. IRMA and the test of serum anti-ureB antibody was not significantly different from the 'golden standard' (X 2 =1.165, P>0.05), but RUT and PCR showed statistically significant difference with the 'gold standard' (X 2 =5.333, 9.436; all P<0.05). Conclusion: IRMA for HP ureB antigen is a sensitive and specific method for detection of HP infection, and can be used in the study of etiology and pathogenesis of gastric and some other related diseases. (authors)

  12. Serum vitamin d levels and the components of metabolic syndrome: an analytical cross-sectional study

    International Nuclear Information System (INIS)

    Roomi, M.A.; Farooq, A.; Ullah, E.; Lone, K.P.

    2015-01-01

    The present study was planned to determine the serum vitamin D levels and its relation with the various components of metabolic syndrome (MetS) in MetS positive and MetS negative subjects. Methods: This analytical cross-sectional study on 88 subjects who were divided into two groups based on whether they fulfill the diagnostic criteria for MetS or not. Fasting serum glucose, lipid profile, insulin, HOMA-IR and vitamin D levels were measured. Two sample-t test and Mann-Whitney U tests were used to compare the differences. Pearson and Spearman correlation tests were used to observe the correlations. Results: BMI (p=0.001), waist/hip ratio (p=0.001), systolic blood pressure (p=0.010), diastolic blood pressure (p=0.010), fasting serum TGs (p = 0.001), TG/HDL ratio (p=0.001), fasting blood sugar (p=0.010), fasting serum insulin (p = 0.001) and HOMA-IR (p=0.001) were significantly high in MetS positive than MetS negative subjects. In MetS Positive subjects, serum vitamin D levels were found to have negative correlation with serum LDL (r= -0.485, p=0.001), total cholesterol (r= -0.408, p=0.007) and total cholesterol/HDL ratio (r= -0.355, p=0.019). Moreover, serum vitamin D levels were found to have positive correlation with HDL/LDL ratio (r= 0.443, p=0.003). Other components of MetS did not show significant correlation with serum vitamin D levels in MetS positive subjects. In MetS negative subjects, serum vitamin D levels did not show any significant correlation with any of the study parameters. Conclusions: Serum vitamin D levels were correlated with a number of MetS components which may be controlled by optimizing vitamin D levels. (author)

  13. Serum lysozyme determinations, April-June 1961

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S C; Lamphere, J P; Jablon, S

    1963-04-18

    Serum lysozyme levels were determined on 670 consecutive subjects seen for regularly scheduled clinic examinations of the Adult Health Study in Hiroshima. Serum lysozyme levels were found to vary significantly with the absolute peripheral granulocyte count, age, sex, and month of study. A high level of correlation also was noted between serum lysozyme and diabetes mellitus. This was at least in part attributable to greater average age in patients with diabetes. Suggestive relationship was established between serum lysozyme levels, respiratory diseases, and tuberculosis. These changes are believed to reflect active inflammation with excessive destruction of granulocytes and parenchymal tissues in those patients with the more acute processes. No relationship was found between serum lysozyme and previous exposure to ionizing radiation. These studies indicate that the serum lysozyme level may be useful in the study of the kinetics of leukopoiesis, the aging process, and in the detection of subtle inflammatory processes. 21 references, 5 tables.

  14. 125I Radioimmunoassay of serum ursodeoxycholyl conjugates

    International Nuclear Information System (INIS)

    Hill, A.; Ross, P.E.; Bouchier, I.A.D.

    1983-01-01

    A radioimmunoassay for serum ursodeoxycholic conjugates using an iodine-125 ligand has been developed. The bile acid was present in normal fasting serum (0.19 +- SD 0.19 μmol/l, n=24) and 2-hour post-prandial serum (0.8 +- SD 0.8 μmol/l, n=16). Gallstone patients undergoing oral ursodeoxycholic acid therapy had significantly higher post-prandial serum levels (21.5 +- SD 14.0 μmol/l, n=15) by radioimmunoassay. Gas liquid chromatography analysis indicated that in normal serum ursodeoxycholic acid was totally conjugated, whereas sera from gallstone patients contained a proportion as the free bile acid (10.2 +- SD 8.1 μmol/l, n=15). Following an oral dose of ursodeoxycholic acid, both unconjugated and conjugated forms of the bile acid appeared in the serum of healthy individuals. (Auth.)

  15. Serum and Plasma Metabolomic Biomarkers for Lung Cancer.

    Science.gov (United States)

    Kumar, Nishith; Shahjaman, Md; Mollah, Md Nurul Haque; Islam, S M Shahinul; Hoque, Md Aminul

    2017-01-01

    In drug invention and early disease prediction of lung cancer, metabolomic biomarker detection is very important. Mortality rate can be decreased, if cancer is predicted at the earlier stage. Recent diagnostic techniques for lung cancer are not prognosis diagnostic techniques. However, if we know the name of the metabolites, whose intensity levels are considerably changing between cancer subject and control subject, then it will be easy to early diagnosis the disease as well as to discover the drug. Therefore, in this paper we have identified the influential plasma and serum blood sample metabolites for lung cancer and also identified the biomarkers that will be helpful for early disease prediction as well as for drug invention. To identify the influential metabolites, we considered a parametric and a nonparametric test namely student׳s t-test as parametric and Kruskal-Wallis test as non-parametric test. We also categorized the up-regulated and down-regulated metabolites by the heatmap plot and identified the biomarkers by support vector machine (SVM) classifier and pathway analysis. From our analysis, we got 27 influential (p-value<0.05) metabolites from plasma sample and 13 influential (p-value<0.05) metabolites from serum sample. According to the importance plot through SVM classifier, pathway analysis and correlation network analysis, we declared 4 metabolites (taurine, aspertic acid, glutamine and pyruvic acid) as plasma biomarker and 3 metabolites (aspartic acid, taurine and inosine) as serum biomarker.

  16. Serum AMH in Physiology and Pathology of Male Gonads

    Directory of Open Access Journals (Sweden)

    Ewa Matuszczak

    2013-01-01

    Full Text Available AMH is secreted by immature Sertoli cells (SC and is responsible for the regression of Müllerian ducts in the male fetus as part of the sexual differentiation process. AMH is also involved in testicular development and function. AMHs are at their lowest levels in the first days after birth but increase after the first week, likely reflecting active SC proliferation. AMH rises rapidly in concentration in boys during the first month, reaching a peak level at about 6 months of age, and then slowly declines during childhood, falling to low levels in puberty. Basal and FSH-stimulated levels of AMH, might become a useful predictive marker of the spermatogenic response to gonadotropic treatment in young patients with hypogonadotropic hypogonadism. After puberty, AMH is released preferentially by the apical pole of the SC towards the lumen of the seminiferous tubules, resulting in higher concentrations in the seminal plasma than in the serum. Defects in AMH production and insensitivity to AMH due to receptor defects result in the persistent Müllerian duct syndrome. A measurable value of AMH in a boy with bilateral cryptorchidism is predictive of undescended testes, while an undetectable value is highly suggestive of anorchia or ovaries, as would be the case in girls with female pseudohermaphroditism and pure gonadal dysgenesis. Lower serum AMH concentrations in otherwise healthy boys with cryptorchidism, who were compared with their age-matched counterparts with palpable testes, have been reported previously. AMH levels are higher in prepubertal patients with varicocele than in controls. This altered serum profile of AMH in boys with varicoceles may indicate an early abnormality in the regulation of the seminiferous epithelial function. Serum AMH is known to be valuable in assessing gonadal function. As compared to testing involving the administration of human chorionic gonadotropin, the measurement of AMH is more sensitive and equally specific

  17. Radioimmunoassay of thyrotropin concentrated from serum

    International Nuclear Information System (INIS)

    Nisula, B.C.; Louvet, J.P.

    1978-01-01

    A method for concentrating human TSH (hTSH) from serum for use in RIAs is described. The method takes advantage of the affinity of the plant lectin, concanavalin A, for the carbohydrate portion of the hTSH molecule. The hTSH from 2.5 ml serum was adsorbed to concanavalin A covalently linked to sepharose and then radioimmunoassayed using the hTSH antiserum and hTSH for iodination distributed by the National Pituitary Agency. For the RIA standard curve, the hTSH reference preparation was concentrated from a serum wwith undetectable hTSH in order to correct for recovery and to control for nonspecific effects. The percentage of serum hTSH extracted from 2.5 ml serum with the concentration procedure was 76.6 +- 3.4% (mean +- SD). The coefficient of correlation between serum hTSH, determined with the concentration procedure, and serum hTSH determined without was 0.979 (P < 0.001). Over 95% of normal adult men and women had detectable levels of serum hTSH, ranging from < 0.56 to 4.0 μU/ml. The mean of detectable serum hTSH levels in normal adult women (n = 11) was 1.54 +- 1.03 μU/ml (mean +- SD) and in normal men (n = 9) was 2.02 +- 1.15 μU/ml (mean +- SD). Clinically hyperthyroid patients with diffuse and nodular toxic goiters (n = 8) and patients with hypothyroidism secondary to pituitary disease (n = 6), four of whom were taking replacement doses of thyroid hormone, had undetectable serum hTSH levels. Serum hTSH in patients with primary hypothyroidism uniformly exceeded the normal range. This hTSH concentrating procedure enhances the effective sensitivity and, therefore, the clinical utility of the RIA for hTSH in serum

  18. Human autologous serum as a substitute for fetal bovine serum in human Schwann cell culture.

    Directory of Open Access Journals (Sweden)

    Parisa Goodarzi

    2014-04-01

    Full Text Available Nowadays, cell -based and tissue engineered products have opened new horizons in treatment of incurable nervous system disorders. The number of studies on the role of Schwann cells (SC in treating nervous disorders is higher than other cell types. Different protocols have been suggested for isolation and expansion of SC which most of them have used multiple growth factors, mitogens and fetal bovine sera (FBS in culture medium. Because of potential hazards of animal-derived reagents, this study was designed to evaluate the effect of replacing FBS with human autologous serum (HAS on SC's yield and culture parameters. Samples from 10 peripheral nerve biopsies were retrieved and processed under aseptic condition. The isolated cells cultured in FBS (1st group or autologous serum (2nd group. After primary culture the cells were seeded at 10000 cell/cm2 in a 12 wells cell culture plate for each group. At 100% confluency, the cell culture parameters (count, viability, purity and culture duration of 2 groups were compared using paired t-test. The average donors' age was 35.80 (SD=13.35 and except for 1 sample the others cultured successfully. In first group, the averages of cell purity, viability and culture duration were 97% (SD=1.32, 97/33% (SD=1.22 and 11.77 (SD=2.58 days respectively. This parameters were 97.33% (SD=1.00, 97.55% (SD=1.33 and 10.33 days (SD=1.65 in second group. The difference of cell count, purity and viability were not significant between 2 groups (P>0.05. The cells of second group reached to 100% confluency in shorter period of time (P=0.03. The results of this study showed that autologous serum can be a good substitute for FBS in human SC culture. This can reduce the costs and improve the safety of cell product for clinical application.

  19. Serum lipids in hypothyroidism: Our experience

    OpenAIRE

    Prakash, Archana; Lal, Ashok Kumar

    2006-01-01

    In order to determine whether the screening of lipid profile is justified in patients with hypothyroidism we estimated serum lipids in cases having different levels of serum TSH. 60 patients of hypothyroidism in the age group of 20 to 60 yrs were studied for thyroid profile over a period of one year. On the basis of serum TSH level the cases were divided into three groups: In the first group TSH concentration was 8.8±2.99 μlU/ml, 95% confidence interval (Cl) 8.8±1.07, whereas serum total chol...

  20. Use of containers with sterilizing filter in autologous serum eyedrops.

    Science.gov (United States)

    López-García, José S; García-Lozano, Isabel

    2012-11-01

    To assess the effect of the use of containers with an adapted sterilizing filter on the contamination of autologous serum eyedrops. Prospective, consecutive, comparative, and randomized study. Thirty patients with Sjögren syndrome. One hundred seventy-six autologous serum containers used in home therapy were studied; 48 of them included an adapted filter (Hyabak; Thea, Clermont-Ferrand, France), and the other 128 were conventional containers. Containers equipped with a filter were tested at 7, 14, 21, and 28 days of use, whereas conventional containers were studied after 7 days of use. In addition, testing for contamination was carried out in 14 conventional containers used during in-patient therapy every week for 4 weeks. In all cases, the preparation of the autologous serum was similar. Blood agar and chocolate agar were used as regular culture media for the microbiologic studies, whereas Sabouraud agar with chloramphenicol was the medium for fungal studies. Microbiologic contamination of containers with autologous serum eyedrops. Only one of the containers with an adapted sterilizing filter (2.1%) became contaminated with Staphylococcus epidermidis after 1 month of treatment, whereas the contamination rate among conventional containers reached 28.9% after 7 days of treatment. The most frequent germs found in the samples were coagulase-negative Staphylococcus (48.6%). With regard the containers used in the in-patient setting, 2 (14.3%) became contaminated after 2 weeks, 5 (35.7%) became contaminated after 3 weeks, and 5 (50%) became contaminated after 4 weeks, leaving 7 (50%) that did not become contaminated after 1 month of treatment. Using containers with an adapted filter significantly reduces the contamination rates in autologous serum eyedrops, thus extending the use of such container by the patients for up to 4 weeks with virtually no contamination risks. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. Effect of body mass index on serum leptin levels

    International Nuclear Information System (INIS)

    Paul, R.F.; Hassan, M.; Nazar, H.S.

    2012-01-01

    Background: Leptin is product of ob gene, an adipose tissue derived hormone that plays a key role in the regulation of body fat mass by regulating appetite and metabolism while balancing energy intake and energy expenditure. The objective of the study was to evaluate possible association between serum leptin levels and Body Mass Index (BMI) of gender in adult age group. Methods: Two-hundred-seventy subjects aged 20-50 years were randomly selected from general population of Abbottabad. The subjects were grouped on the basis on BMI (89 normal, 92 overweight, and 89 obese). After complete evaluation, demographic data was recorded and BMI. Non-fasting venous blood samples were drawn to measure serum leptin and serum glucose levels. The data were analysed using SPSS-15 calculating mean, percentage, independent t-test and chi-square test. Correlation and regression curve analysis were obtained, and p and r values were calculated. Results: Serum leptin levels and differences between genders were significant in all body mass indices. For normal BMI group the mean values for leptin were 2.6+-1.5 gamma g/ml in men, and 17.3+9-10.2 gamma g/ml for women. For Group-2 mean leptin levels in men were 9.9+-6.8 gamma g/ml and in women were 34.8+-13.6 gamma g/ml. For Group-3 BMI comprising obese subjects mean values for men were 21.3+-14.2 gamma g/ml and for women were 48.21+-21.2 gamma g/ml (p<0.001). Conclusion: A progressive increase in serum leptin concentration was observed with an increase in BMI. Significant difference between leptin concentrations in either gender was found in normal, overweight and obese subjects. (author)

  2. Afternoon serum-melatonin in sleep disordered breathing.

    Science.gov (United States)

    Ulfberg, J; Micic, S; Strøm, J

    1998-08-01

    To study afternoon serum-melatonin values in patients with sleep disordered breathing. Melatonin has a strong circadian rhythm with high values during the night-time and low values in the afternoon. Sleep disordered breathing may change the circadian rhythm of melatonin which may have diagnostic implications. The Sleep Laboratory, The Department of Internal Medicine, Avesta Hospital, Sweden, and the Department of Anaesthesiology, Glostrup University Hospital, Copenhagen, Denmark. We examined 60 consecutive patients admitted for sleep disordered breathing and 10 healthy non snoring controls. The patients underwent a sleep apnoea screening test having a specificity of 100% for the obstructive sleep apnoea syndrome (OSAS) using a combination of static charge sensitive bed and oximetry. Obstructive sleep apnoea syndrome was found in 49 patients, eight patients had borderline sleep disordered breathing (BSDB) and three patients were excluded due to interfering disease. Patients and controls had an afternoon determination of serum-melatonin. The Epworth Sleepiness Scale was used to score day-time sleepiness. In comparison with normal controls patients suffering from OSAS had significantly higher serum-melatonin levels in the afternoon. However, as a diagnostic test for OSAS in patients with sleep disordered breathing serum-melatonin showed a low sensitivity but a high specificity. The results indicate that breathing disorders during sleep in general affect pineal function. Sleep disordered breathing seems to disturb pineal function. Determination of afternoon serum-melatonin alone or together with a scoring of daytime sleepiness does not identify OSAS-patients in a heterogeneous population of patients complaining of heavy snoring and excessive daytime sleepiness.

  3. Serum thyrotropin (TSH) levels in patients with suppressed pituitary function

    International Nuclear Information System (INIS)

    Vasavada, P.; Chen, I.; Maxon, H.; Barnes, E.; Sperling, M.

    1984-01-01

    The diagnosis of borderline hyperthyroidism is difficult. A sensitive radioimmunoassay capable of detecting subnormal levels of serum TSH may be of value in confirming this diagnosis because of the suppressed pituitary function in this disease state. This sensitive assay may also be useful in monitoring the suppression of pituitary function in thyroid cancer patients receiving thyroid hormone therapy. A sensitive radioimmunoassay capable of detecting serum TSH levels as low as 0.25 μU/m1 with coefficients of variation less than 17.2% was used to measure serum TSH levels in 80 healthy subjects, 44 hyperthyroid patients, and 25 athyrotic thyroid cancer patients on daily suppressive doses of thyroxine. All healthy subjects had detectable TSH levels with a mean value of 1.17 and two standard deviation ranges of 0.41 - 2.70 μU/m1 (lognormal distribution). Although the mean +-1 SEM value of 0.63 +- 0.003 μUm1 for hyperthyroid patients and 0.76 +- 0.08 μU/ml for thyroid cancer patients were significantly lower than that of healthy subjects (t-test, p<0.05), subnormal levels of serum TSH were found in only 28.6% (12/42) and 24% (6/25) of hyperthyroid and thyroid cancer patients, respectively. TSH stimulation tests performed in 6 of the cancer patients all gave suppressed responses. Because of considerable overlap, serum TSH levels alone cannot distinguish hyperthyroidsm from euthyroidism. However, a sensitive TSH radioimmunoassay such as the one described here may be of value in evaluating the extent of pituitary suppression in thyroid cancer therapy

  4. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    Science.gov (United States)

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  5. Primary Open-Angle Glaucoma and Serum Lipids

    Directory of Open Access Journals (Sweden)

    Suzana Pavljašević

    2009-02-01

    Full Text Available The aim of this paper was to prove the relation between serum lipid values (cholesterol, trig- lyceride, low density cholesterol, high density cholesterol and primary open -angle glaucoma. The study includes two patient groups: 50 patients with primary open-angle glaucoma and 50 patients without this disease. However, all 100 patients were tested for serum lipid values. The research covered a period of six months (from May to December 2007.. Primary open-angle glaucoma was diagnosed with intraocular pressure values (between 20,1 and 25,6 mm Hg measured with Schiotz tonometry. The visual field changes were confirmed with Goldmann perimetry. The gonioscopies were done for diagnosis confirmation. The serum lipid values were confirmed with enzymatic colorimetry in vitro method. U-test (Mann-Witney-Wilcox test and t-test, as nonparametric tests, were used for statistical evaluations. The cholesterol mean value in the test group was 6,14 mol/dm1 (3,20-8,10 mol/dm3 whereas in the control group it was 5,96 mol/dm3 (2,70-8,80 mol/dm3. U-test was with negative ranks (z=-0,83 AS=0,678. The triglyceride mean value in the test group was 2,38 mol/dm3 (0,84-11,73 mol/m3 and in the control group it was 2,04 mol/dm3 (0,63-5,89 mol/dm3. U-test was with positive ranks (z=0,950 AS=0,342. High density cholesterol was average in the test group with 1,45 mol/dm3 (0,71-3,40 mol/dm3 and in the control group 1,40 mol/m3 (0,80-3,20 mol/dm3. Low density cholesterol in the test group was 3,98 mol/m3 (1,82-6,49 mol/m3 and in the control group 4,08 mol/m3 (2,69-5,69 mol/m3. These results had positive ranks according to U-test. Serum lipid values could be one of predictable factors in primary open-angle glaucoma diagnosis. Due to the patient age, cholesterol values, as common factors in primary open-angle glaucoma and atherosclerosis genesis, could be concern in the same aetiology based on dyslipidaemia as well.

  6. Valores séricos de vitamina A e teste terapêutico em pré-escolares atendidos em uma Unidade de Saúde do Rio de Janeiro, Brasil Serum vitamin A levels and therapeutic test in preschool children attended in a Health Unit of Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Rejane Andréa RAMALHO

    2001-04-01

    Full Text Available Foi avaliado o impacto da suplementação com doses maciças de vitamina A (200.000 UI em pré-escolares atendidos em unidade de saúde do Rio de Janeiro. Inicialmente avaliou-se o nível de retinol sérico e as medidas antropométricas em 175 pré-escolares atendidos pelo Serviço Materno-infantil da Universidade Federal do Rio de Janeiro. Forneceu-se, então, uma dose maciça de 200.000 UI de vitamina A solicitando o retorno após 30 dias. Nas crianças que retornaram após este período (n=99, refez-se a avaliação de retinol sérico. A prevalência de hipovitaminose A (The impact of a massive dose of vitamin A on preschool children attended in a health unit from Rio de Janeiro was evaluated. Initially, serum retinol levels and anthropometric measurements were determined in 175 preschool children attended in the Children's Service of the Universidade Federal do Rio de Janeiro, after which a massive (200.000 IU dose of vitamin A was provided. The children were requested to return to the unit after 30 days. Serum retinol levels were measured in the children who returned (n=99. The prevalence of low (below 1.05 µmol/L levels of circulating retinol was of 34.3% in all children evaluated in the first attendance. After 30 days the prevalence was reduced from 42.4 to 3.0%. The lower the initial retinol levels the better the benefit from the massive dose. The proportion of children with protein-energy malnutrition was of 4.6%, but no clear association was found between vitamin A deficiency and protein-energy malnutrition. Vitamin A deficiency was independent of the household income and educational level of the parents. The response of children with vitamin A deficiency to the massive dose indicates that a low vitamin A intake may play an important role in the etiology of the problem. The prevalence figures also demonstrate that this problem is not exclusive of the traditionally poor areas of the country.

  7. Genetic factors explain half of all variance in serum eosinophil cationic protein

    DEFF Research Database (Denmark)

    Elmose, Camilla; Sverrild, Asger; van der Sluis, Sophie

    2014-01-01

    with variation in serum ECP and to determine the relative proportion of the variation in ECP due to genetic and non-genetic factors, in an adult twin sample. METHODS: A sample of 575 twins, selected through a proband with self-reported asthma, had serum ECP, lung function, airway responsiveness to methacholine......, exhaled nitric oxide, and skin test reactivity, measured. Linear regression analysis and variance component models were used to study factors associated with variation in ECP and the relative genetic influence on ECP levels. RESULTS: Sex (regression coefficient = -0.107, P ... was statistically non-significant (r = -0.11, P = 0.50). CONCLUSION: Around half of all variance in serum ECP is explained by genetic factors. Serum ECP is influenced by sex, BMI, and airway responsiveness. Serum ECP and airway responsiveness seem not to share genetic variance....

  8. Clinical significance of determination of serum VEGF and CEA levels in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Du Xiaohui; Song Shaobai; Zheng Wei

    2007-01-01

    Objective: To study the applicability of combined determination of serum VEGF and CEA levels in the diagnosis of colorectal cancer as well as the relationship between VEGF level and stage of the disease. Methods: Serum VEGF (with ELISA) and CEA (with RIA) levels serum were detected in 28 patients with colorectal cancer of various stages and 29 controls. Results: The diagnostic positive rate was 53.6% (15/28), 39.3% (11/28), 71.4% (20/28) with CEA, VEGF and combined test for colorectal cancer, respectively. The serum VEGF levels in patients with advance colorectal cancer were significantly higher than those in patients with earlier stages diseases and controls, VEGF levels were positively correlated with CEA levels (P<0.05). Conclusion: Combined detection of the levels of serum VEGF and CEA could improve significantly the diagnostic positive rate in patients with colorectal cancer. (authors)

  9. Ultrasonographic diagnosis of fatty liver and relations with body index, serum lipid, and serum triglyceride

    International Nuclear Information System (INIS)

    Jang, Young Deog; Lee, S. H.; Lee, H. K.; Kim, D. H.; Kwon, K. H.; Kim, K. C.

    1989-01-01

    Hepatic fatty infiltration appears as an area of increased echogenicity. And many factors concerned to fatty infiltration. With 65 cases of fatty liver and 42 cases of normal group, we analyzed fatty liver with grading and attempt to find relations between grade of fatty liver and levels of body index, serum triglyceride, and serum lipid. And compared fatty liver with normal control group. Patients with fatty liver are higher percentage of supra-normal value in body index, serum lipid, and serum triglyceride than normal control group. As fatty infiltration progressed, serum lipid, serum trig-lyceride and body index are also increased. Conclusively ultrasonographic examination of liver with serum triglyceride, serum lipid, and body index are simple method, useful follow-up examination of fatty liver, and preventive routine check-up of chronic liver disease

  10. Bone mineralisation in premature infants cannot be predicted from serum alkaline phosphatase or serum phosphate

    DEFF Research Database (Denmark)

    Faerk, J; Peitersen, Birgit; Petersen, S

    2002-01-01

    BACKGROUND: The bone mineral content of premature infants at term is lower than in mature infants at the same postconceptional age. Serum alkaline phosphatase and serum phosphate are often used as indicators of bone mineralisation. OBJECTIVE: To analyse the association between bone mineral content...... content was measured at term (mean gestational age 41 weeks) by dual energy x ray absorptiometry and corrected for body size. RESULTS: Serum alkaline phosphatase was significantly negatively associated with serum phosphate (p mineral content was not associated with mean serum alkaline...... and serum alkaline phosphatase and serum phosphate. METHODS: Serum alkaline phosphatase and phosphate were measured at weekly intervals during admission in 108 premature infants of gestational age below 32 weeks (mean (SD) gestational age 29 (2) weeks; mean (SD) birth weight 1129 (279) g). Bone mineral...

  11. Serum tau and neurological outcome in cardiac arrest

    DEFF Research Database (Denmark)

    Mattsson, Niklas; Zetterberg, Henrik; Nielsen, Niklas

    2017-01-01

    OBJECTIVE: To test serum tau as a predictor of neurological outcome after cardiac arrest. METHODS: We measured the neuronal protein tau in serum at 24, 48, and 72 hours after cardiac arrest in 689 patients in the prospective international Target Temperature Management trial. The main outcome...... was poor neurological outcome, defined as Cerebral Performance Categories 3-5 at 6 months. RESULTS: Increased tau was associated with poor outcome at 6 months after cardiac arrest (median = 38.5, interquartile range [IQR] = 5.7-245ng/l in poor vs median = 1.5, IQR = 0.7-2.4ng/l in good outcome, for tau....... The accuracy in predicting outcome by serum tau was equally high for patients randomized to 33 °C and 36 °C targeted temperature after cardiac arrest. INTERPRETATION: Serum tau is a promising novel biomarker for prediction of neurological outcome in patients with cardiac arrest. It may be significantly better...

  12. Changes in serum desnutrin levels in patients with acne vulgaris.

    Science.gov (United States)

    Demir, Betul; Ucak, Haydar; Cicek, Demet; Aydin, Suleyman; Erden, Ilker; Dertlioglu, Selma Bakar

    2014-01-01

    Androgens and insulin may contribute to increased sebum production in the pathogenesis of acne vulgaris. We investigated the association between serum desnutrin levels and acne vulgaris in the pathogenesis of insulin resistance. 25 patients presenting with acne vulgaris and 25 control subjects participated in this study. Fasting blood glucose, triglycerides, LDL, VLDL, HDL, total cholesterol, insulin, C-peptide and thyroid function tests were measured. The homeostasis model assessment of insulin resistance (HOMA-IR) was used to calculate insulin resistance. Desnutrin levels were determined by enzyme-linked immunosorbent assay (ELISA) according to the manufacturer's protocol. Patients with acne vulgaris had a mean serum desnutrin level of (8.83 ± 1.13 μIU/mL), which was statistically significantly lower in the control group (10:58 ± 3.43 μIU/mL). In patients with acne vulgaris the serum glucose levels, insulin levels and HOMA-IR values (87.92 ± 7:46 mg/dL, 11.33 ± 5.93 μIU/mL, 2.49 ± 1.40, respectively) were significantly higher than the control group (77.36 ± 9.83 mg/dL, 5.82 ± 2.68 μIU/mL, 1.11 ± 0.51, respectively) (p = 0.01, pacne vulgaris, as a result of increased levels of serum glucose and insulin, the function of desnutrin was suppressed, perhaps contributing to insulin resistance.

  13. Serum hyaluronic acid levels during pregnancy and labor.

    Science.gov (United States)

    Kobayashi, H; Sun, G W; Tanaka, Y; Kondo, T; Terao, T

    1999-04-01

    To study the changes in concentrations of serum hyaluronic acid in uncomplicated human pregnancies. We determined the concentrations of serum hyaluronic acid, using a specific enzyme-linked immunosorbent assay, in 70 nonpregnant women, 250 women during their pregnancies, and 68 women at the time of parturition. Results were analyzed for statistical significance with Scheffé test for multiple comparisons. During pregnancy, mean (+/- standard deviation) serum hyaluronic acid levels were 11.4 +/- 4.5, 13.6 +/- 2.8, 20.6 +/- 1.5, and 46.9 +/- 7.9 ng/mL at 5-14 (n = 47), 15-26 (n = 46), 27-37 (n = 58), and 38-40 (n = 99) weeks' gestation, respectively. Pregnant women in labor (n = 68) had significantly higher levels (100.4 +/- 11.3 ng/mL) than did women at term but not in labor (P hyaluronic acid concentrations increase as pregnancy progresses and serum levels increase significantly at term. Hyaluronic acid may be associated with cervical ripening during parturition.

  14. Serum Vitamin A Levels in Patients with Chalazion.

    Science.gov (United States)

    Malekahmadi, Mohammad; Farrahi, Fereydoun; Tajdini, Afshin

    2017-01-01

    Chalazion is a chronic, localized lipogranulomatous inflammation of the sebaceous glands of the lids. Chalazion occurs often secondary to blockage of the sebaceous gland ducts. Some studies have reported vitamin A deficiency as a risk factor for chalazion. In this study, we determined the serum levels of vitamin A in patients with chalazion. The study involved a total of 107 subjects (52 patients with chalazion and 55 control healthy subjects). The study was conducted at the Ophthalmology Clinics of Imam Khomeini Hospital, Ahwaz Jundishapur University of Medical Sciences, Ahwaz, Iran between September 2014 and February 2015. The subjects were divided into three groups according to age: 7-12 years old, 13-19 years old, and more than 19 years old. Patients were further divided into four subgroups based on the type of chalazion: single, multiple, primary, and recurrent. Blood samples were collected and the serum was tested for levels of vitamin A using high-performance liquid chromatography (HPLC). The average serum vitamin A levels in patients with chalazion in the age groups of 7-12 and 13-19 years were significantly lower than in their control counterparts. Serum vitamin A levels in patients with recurrent, multiple chalazia were significantly lower than in patients with primary, multiple chalazia (P = 0.026) and patients with a recurrent, single chalazion (P = 0.029). In conclusion, chalazion could be one of the ocular presentations of vitamin A deficiency.

  15. Decreased serum hepcidin concentration correlates with brain iron deposition in patients with HBV-related cirrhosis.

    Directory of Open Access Journals (Sweden)

    Dong Lin

    Full Text Available PURPOSE: Excessive brain iron accumulation contributes to cognitive impairments in hepatitis B virus (HBV-related cirrhotic patients. The underlying mechanism remains unclear. Hepcidin, a liver-produced, 25-aminoacid peptide, is the major regulator of systemic iron metabolism. Abnormal hepcidin level is a key factor in some body iron accumulation or deficiency disorders, especially in those associated with liver diseases. Our study was aimed to explore the relationship between brain iron content in patients with HBV-related cirrhosis and serum hepcidin level. METHODS: Seventy HBV-related cirrhotic patients and forty age- sex-matched healthy controls were enrolled. Brain iron content was quantified by susceptibility weighted phase imaging technique. Serum hepcidin as well as serum iron, serum transferrin, ferritin, soluble transferrin receptor, total iron binding capacity, and transferrin saturation were tested in thirty cirrhotic patients and nineteen healthy controls. Pearson correlation analysis was performed to investigate correlation between brain iron concentrations and serum hepcidin, or other iron parameters. RESULTS: Cirrhotic patients had increased brain iron accumulation compared to controls in the left red nuclear, the bilateral substantia nigra, the bilateral thalamus, the right caudate, and the right putamen. Cirrhotic patients had significantly decreased serum hepcidin concentration, as well as lower serum transferring level, lower total iron binding capacity and higher transferrin saturation, compared to controls. Serum hepcidin level negatively correlated with the iron content in the right caudate, while serum ferritin level positively correlated with the iron content in the bilateral putamen in cirrhotic patients. CONCLUSIONS: Decreased serum hepcidin level correlated with excessive iron accumulation in the basal ganglia in HBV-related cirrhotic patients. Our results indicated that systemic iron overload underlined regional

  16. The Changes of Serum TSH in Various States of Thyroid Function

    International Nuclear Information System (INIS)

    Ro, Heung Kyu

    1975-01-01

    The serum concentrations of thyrotropin (TSH) were measured by means of radioimmunoassay, in 98 cases of normal controls, 51 cases of hyperthyroidism, 80 cases of primary hypothyroidism and 4 cases of secondary hypothyroidism to evaluate the diagnostic significance in various functional states of the thyroid. The obtained data were analyzed in correlation with other thyroid function test values in various phases of the functional thyroid diseases. The results were as follows: 1) The serum TSH concentration in normal control group was (1.3-8.0 μU/ml). 2) The measurement of serum TSH was more significant in diagnostic accuracy compared with that of serum T 4 (75.0±12.2%). Free T-4 Index (64.2±15.2%), serum T 3 (41.0±21.0%) or T 3 resin uptake (41.1±15.8%) in evaluation of primary hypothyroidism. 3) In case of overt hypothyroidism, the serum TSH and T 4 were both abnormal, compatible with the clinical diagnosis, while in case of preclinical or mild hypothyroidism, the serum T 4 (41.2±23.8% or 50.0±25.0%) was much less reliable than serum TSH. 4) In the treatment of primary hypothyroidism with desiccated thyroid, the administration of 1 grain of the hormone per day was sufficient to suppress the serum concentration of TSH to normal range. It showed that the measurement of serum TSH concentration was a significant criteria in evaluating the efficiency of the treatment of hypothyroidism. 5) The measurement of serum TSH concentration is a very significant method in the early detection of hypothyroidism induced during or after the treatment of the hyperthyroidism with antithyroid drugs or radioactive Iodine ( 131 I).

  17. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  18. Study of cross-reactivity in serum samples from dogs positive for Leishmania sp., Babesia canis and Ehrlichia canis in enzyme-linked immunosorbent assay and indirect fluorescent antibody test Estudo da reatividade cruzada em amostras de soro de cães positivos para Leishmania sp., Babesia canis e Ehrlichia canis, pelo ensaio imunoenzimático indireto e pela reação de imunofluorescência indireta

    Directory of Open Access Journals (Sweden)

    Trícia Maria F. de Sousa Oliveira

    2008-03-01

    Full Text Available To verify the presence of cross-reaction among leishmaniosis, ehrlichiosis and babesiosis in serological diagnostics used in human visceral leishmaniasis control programs, serum samples from leishmaniasis endemic and non-endemic areas were collected and tested by Indirect Fluorescent Antibody (IFAT and Enzyme-linked immunosorbent assay (ELISA. All serum samples from endemic areas were positive for Leishmania sp., by ELISA and IFAT, 51% positive for Babesia canis and 43% for Ehrlichia canis by IFAT. None of the serum samples from non-endemic areas were positive for Leishmania sp., by IFAT, but 67% were positive for B. canis and 78% for E. canis using the same test. When tested by ELISA for Leishmania sp., four samples from non-endemic area were positive. These dogs were then located and no clinical signs, parasites or antibody was detected in new tests for a six month period. Only one of these 4 samples was positive for B. canis by IFAT and ELISA and three for E. canis by IFAT. The results of the work suggest a co-infection in the endemic area and no serological cross-reaction among these parasites by IFAT and ELISA.Para verificar a existência de reação cruzada entre leishmaniose visceral, erliquiose e babesiose, nos testes sorológicos utilizados em programas de controle da leishmaniose visceral humana, amostras de soro canino provenientes de áreas endêmicas e não endêmicas para essa enfermidade, foram testadas pela Reação de Imunofluorescência (RIFI e Ensaio imunoenzimático (ELISA. Todos os soros provenientes de área endêmica foram positivos para Leishmania sp pelo ELISA e RIFI, 51% para Babesia canis e 43% para Ehrlichia canis pela RIFI. Pela RIFI, nenhum dos soros provenientes de área não endêmica foi positivo para Leishmania sp, sendo 67% positivos para B. canis e 78% para E. canis pelo mesmo teste. Quando testados pelo ELISA para Leishmania sp., quatro soros da área não endêmica foram positivos. Os cães foram localizados

  19. Association between serum uric acid levels and obesity among university students (China).

    Science.gov (United States)

    Duan, Ying; Liang, Wei; Zhu, Lijun; Zhang, Ting; Wang, Linghong; Nie, Zhognhua; Chen, Yan; He, Lianping; Jin, Yuelong; Yao, Yingshui

    2015-06-01

    To evaluate the association between serum uric acid and obesity among university students who participated in routine health screening in 2013. In this cross-sectional study, 3529 subjects were analyzed. Obesity categories were classified by BMI levels references in China. And serum uric acid levels were classified by serum uric acid quartiles. Two-sample T-test and Wilcoxon Rank sum test were used to compare age, biochemical and anthropometric parameters of subjects of two genders. Rank correlation used to analyze relationship between serum uric acid and obesity. There were 1285 males (mean age, 19.8 ± 1.3 years) and 2244 females (mean age, 19.9 ± 1.3 years) in this study. Association between 2nd serum uric acid quartile and normal in male are significant and coefficient was 0.519. The 3rd serum uric acid quartile and normal in female was associated significantly (r = 0.173, p = 0.010). And associations between overweight and 3rd and 4th serum uric acid quartiles in female were significant (r = 0.128, p = 0.038 in 1st quartile and r = 0.282, p = 0.004 in 4th quartile). The 4th serum uric acid quartile and Obesity in two gender groups were significantly associated (r = 0.291, p = 0.000 in male and r = 0.484, p = 0.001 in female). High serum uric acid was positively associated with obesity in overweight and obesity group. However, the association was weak between two variables because serum uric acid influenced obesity with other related factors together. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  20. Anti-insulin antibody test

    Science.gov (United States)

    Insulin antibodies - serum; Insulin Ab test; Insulin resistance - insulin antibodies; Diabetes - insulin antibodies ... Normally, there are no antibodies against insulin in your blood. ... different laboratories. Some labs use different measurements or ...

  1. Impact of Prolonged Blood Incubation and Extended Serum Storage at Room Temperature on the Human Serum Metabolome

    Directory of Open Access Journals (Sweden)

    Beate Kamlage

    2018-01-01

    Full Text Available Metabolomics is a powerful technology with broad applications in life science that, like other -omics approaches, requires high-quality samples to achieve reliable results and ensure reproducibility. Therefore, along with quality assurance, methods to assess sample quality regarding pre-analytical confounders are urgently needed. In this study, we analyzed the response of the human serum metabolome to pre-analytical variations comprising prolonged blood incubation and extended serum storage at room temperature by using gas chromatography-mass spectrometry (GC-MS and liquid chromatography-tandem mass spectrometry (LC-MS/MS -based metabolomics. We found that the prolonged incubation of blood results in a statistically significant 20% increase and 4% decrease of 225 tested serum metabolites. Extended serum storage affected 21% of the analyzed metabolites (14% increased, 7% decreased. Amino acids and nucleobases showed the highest percentage of changed metabolites in both confounding conditions, whereas lipids were remarkably stable. Interestingly, the amounts of taurine and O-phosphoethanolamine, which have both been discussed as biomarkers for various diseases, were 1.8- and 2.9-fold increased after 6 h of blood incubation. Since we found that both are more stable in ethylenediaminetetraacetic acid (EDTA blood, EDTA plasma should be the preferred metabolomics matrix.

  2. Serum release boosts sweetness intensity in gels

    NARCIS (Netherlands)

    Sala, G.; Stieger, M.A.; Velde, van de F.

    2010-01-01

    This paper describes the effect of serum release on sweetness intensity in mixed whey protein isolate/gellan gum gels. The impact of gellan gum and sugar concentration on microstructure, permeability, serum release and large deformation properties of the gels was determined. With increasing gellan

  3. Serum testosterone concentration in chloroquine- treated rats ...

    African Journals Online (AJOL)

    ONOS

    2010-07-05

    Jul 5, 2010 ... The effects of ascorbic acid (vitamin C) and alpha-tocopherol (vitamin E) were studied on serum testosterone ... chloroquine are probably mediated via the generation of free radicals. ... Effects of ascorbic acid and alpha-tocopherol on serum testosterone concentration in chloroquine-treated rats. Groups.

  4. Serum bicarbonate and dehydration severity in gastroenteritis

    OpenAIRE

    Narchi, H.

    1998-01-01

    The concentration of bicarbonate was measured in serum samples from 106 children with gastroenteritis and dehydration. A concentration less than 22 mmol/l was more common in children with severe dehydration, but the magnitude of bicarbonate reduction was not significantly different with increasing degrees of dehydration. Doctors should not rely on the serum bicarbonate concentration when assessing fluid deficit.



  5. Determination of serum IgD radioimmunoassay

    International Nuclear Information System (INIS)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l [fr

  6. Determination of serum IgD radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Fayol, V.; Hartmann, D.J.; Sabbagh, I.; Ville, G.

    1986-01-01

    We describe a sensitive liquid phase radioimmunoassay for serum IgD. Extreme values obtained from 85 control patients sera are 0.2 and 121 mg/l with an arithmetic mean of 25 mg/l. In atopic patients (with high serum IgE levels), arithmetic mean is 47 mg/l.

  7. Serum lipids in hypothyroidism: Our experience.

    Science.gov (United States)

    Prakash, Archana; Lal, Ashok Kumar

    2006-09-01

    In order to determine whether the screening of lipid profile is justified in patients with hypothyroidism we estimated serum lipids in cases having different levels of serum TSH. 60 patients of hypothyroidism in the age group of 20 to 60 yrs were studied for thyroid profile over a period of one year. On the basis of serum TSH level the cases were divided into three groups: In the first group TSH concentration was 8.8±2.99 μlU/ml, 95% confidence interval (Cl) 8.8±1.07, whereas serum total cholesterol and LDL-chol levels were 196±37.22 and 126±29.17 mg/dl respectively. The statistical analysis of these two groups showed a significant correlation between raised TSH levels and serum total cholesterol and LDL-chol (Phypothyrodism is associated with changes in lipid profile.

  8. Urine and serum fetuin-A levels in patients with urolithiasis.

    Science.gov (United States)

    Arora, Rajat; Abrol, Nitin; Antonisamy, B; Vanitha, S; Chandrasingh, J; Kumar, Santosh; Kekre, Nitin; Devasia, Antony

    2017-01-01

    Fetuin-A is a glycoprotein secreted by liver and has been shown to inhibit extraosseous mineralization. Urolithiasis may be a manifestation in the urinary tract due to fetuin deficiency in urine. The objective of this study was to compare the 24-h urine and serum fetuin-A levels of patients with and without urolithiasis. Serum and 24-h urine fetuin-A levels were measured in 41 patients with bilateral, multiple, or recurrent urinary tract calculi (Group A) and 41 matched controls with no calculi (Group B). Fetuin levels were measured by enzyme linked immunosorbent assay. Serum and urine fetuin-A levels in the two groups were compared. The median (range) 24-h urine fetuin-A value in Group A was 11.9 (1.12-221) mg/day and in Group B was 37.7 (1.28-125) mg/day. This difference was statistically significant (Mann-Whitney test, P = 0.0169). The median (range) serum fetuin-A in Group A was 0.67 (0.05-2.68) g/L and in Group B was 0.99 (0.01-5.5) g/L. The difference between serum values in the two arms was not statistically significant (Mann-Whitney test, P = 0.1817). However, the serum creatinine-adjusted mean log serum fetuin and urine fetuin were significantly different in the two arms ( P = 0.003). The mean ± standard deviation (range) serum creatinine in Group A was 0.98 ± 0.25 (0.56-1.58) mg% and in Group B was 0.83 ± 0.16 (0.58-1.18) mg% (two sample t -test, P = 0.0031). Patients with urolithiasis have lower urine fetuin-A and creatinine-adjusted serum fetuin-A levels.

  9. Estimation of Serum Triglycerides, Serum Cholesterol, Total Protein, IgG Levels in Chronic Periodontitis Affected Elderly Patients: A Cross-Sectional Study

    Science.gov (United States)

    Saravanan, A. V.; Ravishankar, P. L.; Kumar, Pradeep; Rajapandian, K.; Kalaivani, V.; Rajula, M. Prem Blaisie

    2017-01-01

    Aim: The present study was conducted to evaluate the serum triglycerides, serum cholesterol, total protein, and IgG levels in elderly patients who were affected by periodontal disease. Materials and Methods: This study was conducted at the Rajah Muthiah Dental College and Hospital in the periodontics division. The study was conducted for a period of 3 months. This study is a prospective analytical study. Sixty individuals who were systemically healthy in the age group of 50 and above were included in this study. Control and experimental groups of 30 participants each were included. Plaque index, gingival index, probing pocket depth, and clinical attachment loss were recorded. Biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were also evaluated and correlated with the periodontal parameters. Data was analyzed using SPSS version 16.0 (IBM Corp., Armonk, NY). The relationship between periodontal status and the biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were evaluated by Student's t-test. Results: There was no significant difference in the plaque and gingival scores between the experimental and control group. It was observed that serum cholesterol level and total protein level was lower in participants suffering from chronic periodontitis. Triglycerides level was significantly elevated in the experimental group. IgG, a level which is not significant, concluded that there is no difference in control and experimental group. Conclusion: It was concluded from the results obtained from the study that there is an association between serum triglycerides, serum cholesterol, total protein, and periodontal disease. However, further longitudinal and well-controlled studies are required to evaluate the relationship between these biochemical parameters and periodontal disease. PMID:28462181

  10. Estimation of Serum Triglycerides, Serum Cholesterol, Total Protein, IgG Levels in Chronic Periodontitis Affected Elderly Patients: A Cross-Sectional Study.

    Science.gov (United States)

    Saravanan, A V; Ravishankar, P L; Kumar, Pradeep; Rajapandian, K; Kalaivani, V; Rajula, M Prem Blaisie

    2017-01-01

    The present study was conducted to evaluate the serum triglycerides, serum cholesterol, total protein, and IgG levels in elderly patients who were affected by periodontal disease. This study was conducted at the Rajah Muthiah Dental College and Hospital in the periodontics division. The study was conducted for a period of 3 months. This study is a prospective analytical study. Sixty individuals who were systemically healthy in the age group of 50 and above were included in this study. Control and experimental groups of 30 participants each were included. Plaque index, gingival index, probing pocket depth, and clinical attachment loss were recorded. Biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were also evaluated and correlated with the periodontal parameters. Data was analyzed using SPSS version 16.0 (IBM Corp., Armonk, NY). The relationship between periodontal status and the biochemical parameters such as serum cholesterol, serum triglycerides, total protein, and IgG levels were evaluated by Student's t-test. There was no significant difference in the plaque and gingival scores between the experimental and control group. It was observed that serum cholesterol level and total protein level was lower in participants suffering from chronic periodontitis. Triglycerides level was significantly elevated in the experimental group. IgG, a level which is not significant, concluded that there is no difference in control and experimental group. It was concluded from the results obtained from the study that there is an association between serum triglycerides, serum cholesterol, total protein, and periodontal disease. However, further longitudinal and well-controlled studies are required to evaluate the relationship between these biochemical parameters and periodontal disease.

  11. Interleukin-10 serum level in acute coronary syndrome patients

    Directory of Open Access Journals (Sweden)

    Idrus Alwi

    2009-09-01

    Full Text Available Aim To compare plasma IL-10 concentrations in patients with Acute Coronary Syndrome (ACS with those in Coronary Artery Disease (CAD.Methods ACS patients hospitalized in intensive coronary care unit (ICCU of Cipto Mangunkusumo Hospital/Faculty of Medicine University of Indonesia (CMH/FMUI, Persahabatan Hospital, MMC Hospital, and Medistra Hospital, Jakarta, between May 2005 and May 2006, were included in this study. The ambulatory CAD patients were taken as comparator. The serum IL-10 level was measured by immunoassay method, and compared by using Independent Student’s t-test. To investigate whether IL-10 serum level could predict ACS, the sensitivity and specificity of this parameter towards ACS in various IL-10 serum levels were calculated as well.Results In this observational study, as many as 146 subjects were analyzed, consisting of 84 ACS patients, and 62 coronary artery disease (CAD. The IL-10 level was higher in the group of ACS patients (7.37 pg/mL + 7.81, CI 95% 5.68-9.07 than that in CAD patients (1.59 pg/mL + 1.55, CI 95% 1.2-1.98. The optimal cut-off point for serum IL-10level is >1.95 pg/mL, with 79.76 % sensitivity and 77.42 % specificity.Conclusion The IL-10 level was higher in the ACS patients compared to that in CAD patients. Serum IL-10 measurement is a quite superior method to distinguish acute and stable condition, eventhough it is not as good as hsCRP for the same purpose. (Med J Indones 2009;18:165-9Key words: Interleukin-10, acute coronary syndrome

  12. Decreased Serum 25-Hydroxycalciferol Levels in Pre-diabetic Adults

    International Nuclear Information System (INIS)

    Ain, Q. A.; Khan, D. A.; Ijaz, A.; Khan, F. A.; Latif, A.

    2016-01-01

    Objective: To determine the serum 25-hydroxycalciferol levels [25(OH)D] in adults with pre-diabetes and normoglycaemia to examine a possible association of vitamin D deficiency with pre-diabetes. Study Design: Case control study. Place and Duration of Study: Armed Forces Institute of Pathology, Rawalpindi, from November 2012 to July 2013. Methodology: A total of 272 adults including 136 pre-diabetics and 136 normoglycaemics of either gender aged 20 years and above were consecutively inducted. Patients with diabetes mellitus, pregnancy, rickets and osteomalacia, ischemic heart disease, chronic kidney disease and chronic liver disease were excluded. Fasting Plasma Glucose (FPG) was estimated with hexokinase method on Modular p800 Roche chemistry analyzer while serum 25(OH)D was measured on Diasorin Liaison immunoassay analyzer using the chemiluminescent technique. Mean 25(OH)D levels in pre-diabetic and normoglycaemic groups were compared using Mann-Whitney U test. Spearman's correlation coefficient 'rs' was determined between serum 25(OH)D and FPG. Odds ratio for vitamin D deficiency was also calculated. Results: Mean serum 25(OH)D level was low in pre-diabetics (23.2 nmol/L) as compared to normoglycaemics (29 nmol/L; p=0.001). Serum 25(OH)D level had inverse correlation with FPG (rs = -0.448, p=0.000). There was also significant association of vitamin D deficiency with pre-diabetes compared with normoglycaemia (OR: 2.21, p= 0.016; 95 percentage CI: 1.15-4.27). Conclusion: Vitamin D deficiency with pre-diabetes suggested that vitamin D may have an important role in pathogenesis of pre-diabetes. (author)

  13. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  14. Comparison of Serum Homocystein and Folic Acid Levels in Gestational Diabetes with Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    F. Movahed

    2015-07-01

    Full Text Available Introduction & Objective: High levels of homocystein are a risk factor for insulin resistance, diabetes mellitus and cardio-vascular complications. This study was done to assess serum homocystein and folic acid levels and their relationship in women with gestational diabetes and compare them with normal pregnant women. Materials & Methods: This analytic epidemiologic case-control study was performed in Qazvin Kosar hospital in 2013-2015. 120 singleton pregnant women with 24-28 weeks of gestation according to 2-hour 75g oral glucose tolerance test were assigned to two groups; gestational diabetes (n=60, and normal pregnancy (n=60. Serum homocystein and folic acid levels were measured in two groups. Data were analyzed with statistical t-test and correlation method. Results: In gestational diabetes serum homocystein level was significantly higher (P<0.001 and folic acid was significantly lower (P<0.001 than normal pregnancy group .No relation-ship was observed between serum homocystein and serum folate. In both groups, serum folic acid was significantly related to fasting blood sugar. This relationship was inverse in gesta-tional diabetes group (P<0.001, r = - 0.512 and direct in normal pregnancy group (P=0.001 r =0.417. Conclusion: It seems folic acid has a role in regulation of serum homocystein level and blood sugar.(Sci J Hamadan Univ Med Sci 2015; 22 (2: 93-98

  15. Evaluation of Serum IgA level in nontreated and treated oral squamous cell carcinoma patients

    Directory of Open Access Journals (Sweden)

    Richa Mishra

    2018-01-01

    Full Text Available Introduction: Research in early cancer detection has led to discovery of many immunological tumor markers that contribute considerably to supplement the method of diagnosis. High serum immunoglobulin A (IgA values in patients with cancer have been used as tumor markers. Aims and Objectives: To evaluate and compare the serum IgA levels in nontreated, treated oral squamous cell carcinoma (SCC patients, and control group. Materials and Methods: A total of 60 patients were included in the study. 20 biopsy confirmed oral SCC patients, who have received no medical treatment, 20 oral SCC patients treated with surgery and/or radiotherapy and 20 normal healthy individuals. Venous blood samples were collected from anterior cubital vein and were delivered to the biochemistry laboratory for the estimation of serum IgA level by nephelometry method. Statistical Analysis Used: Statistical method employed were the Pearson's Chi-square test and One-way analysis of variance (Welch followed by Games-Howell post-hoc test. Results: We observed significant difference for serum IgA between study subjects in control, nontreated and treated oral SCC patients (P < 0.001. Serum IgA level in nontreated group was significantly higher than treated group and there was an approximately two-fold increase in serum IgA level in nontreated oral SCC patients when compared to that of the normal healthy individuals. Conclusion: Serum level of IgA might be employed as diagnostic and prognostic indicators in oral cancer.

  16. Systematic review on the role of serum tumor markers in the detection of recurrent pancreatic cancer.

    Science.gov (United States)

    Daamen, Lois A; Groot, Vincent P; Heerkens, Hanne D; Intven, Martijn P W; van Santvoort, Hjalmar C; Molenaar, I Quintus

    2018-04-01

    Biomarker testing can be helpful to monitor disease progression after resection of pancreatic cancer. This systematic review aims to give an overview of the literature on the diagnostic value of serum tumor markers for the detection of recurrent pancreatic cancer during follow-up. A systematic search was performed to 2 October 2017. All studies reporting on the diagnostic value of postoperatively measured serum biomarkers for the detection of pancreatic cancer recurrence were included. Data on diagnostic accuracy of tumor markers were extracted. Forest plots and pooled values of sensitivity and specificity were calculated. Four articles described test results of CA 19-9. A pooled sensitivity and specificity of respectively 0.73 (95% CI 0.66-0.80) and 0.83 (95% CI 0.73-0.91) were calculated. One article reported on CEA, showing a sensitivity of 50% and specificity of 65%. No other serum tumor markers were discussed for surveillance purposes in the current literature. Although testing of serum CA 19-9 has considerable limitations, CA 19-9 remains the most used serum tumor marker for surveillance after surgical resection of pancreatic cancer. Further studies are needed to assess the role of serum tumor marker testing in the detection of recurrent pancreatic cancer and to optimize surveillance strategies. Copyright © 2017 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  17. Thrombin-Accelerated Quick Clotting Serum Tubes: An Evaluation with 22 Common Biochemical Analytes

    Directory of Open Access Journals (Sweden)

    Wai-Yoong Ng

    2013-01-01

    Full Text Available Clot activator serum tubes have significantly improved turnaround times for result reporting compared to plain tubes. With increasing workload and service performance expectations confronting clinical laboratories with high-volume testing and with particular emphasis on critical analytes, attention has focussed on preanalytical variables that can be improved. We carried out a field study on the test performance of BD vacutainer rapid serum tubes (RSTs compared to current institutional issued BD vacutainer serum separator tubes (SSTs in its test result comparability, clotting time, and stability on serum storage. Data from the study population (n=160 of patients attending outpatient clinics and healthy subjects showed that results for renal, liver, lipids, cardiac, thyroid, and prostate biochemical markers were comparable between RSTs and SSTs. Clotting times of the RSTs were verified to be quick with a median time of 2.05 min. Analyte stability on serum storage at 4°C showed no statistically significant deterioration except for bicarbonate, electrolytes, and albumin over a period of 4 days. In conclusion, RSTs offered savings in the time required for the clotting process of serum specimens. This should translate to further trimming of the whole process from blood collection to result reporting without too much sacrifice on test accuracy and performance compared to the current widely used SSTs in most clinical laboratories.

  18. Serum gonadotropins levels in childhood

    International Nuclear Information System (INIS)

    Hertogh, R. De; Vankrieken, L.; Wolter, R.; Vliet, G. Van

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author)

  19. Correlation of Serum Magnesium with Serum Parathormone Levels in Patients on Regular Hemodialysis

    Directory of Open Access Journals (Sweden)

    Baradaran Azar

    2006-01-01

    Full Text Available Secondary hyperparathyroidism (SHPT is a common, important, and treatable complication of end-stage renal disease. This study was conducted to investigate the role of serum magnesium (Mg in regulating the secretion of parathyroid hormone (PTH by the parathyroid gland in patients on maintenance hemodialysis (HD. Pre-dialysis serum levels of calcium (Ca, phosphorus (P, Mg, alkaline phosphatase (ALP, intact serum PTH (iPTH, serum 25-hydroxy Vitamin D (25-OH Vit D and plasma bicarbonate (HCO3 were measured. The Urea Reduction Rate as well as duration and dosage of HD treatment were noted. Our study did not show any significant correlation between serum Mg levels and duration of HD treatment, levels of serum ALP, and plasma HCO3, Ca and P. An inverse correlation, albeit insignificant, was found between the serum Mg levels and iPTH (r=-0.30 p=0.079; also, a significant positive correlation was found between serum Mg levels and serum 25-OH Vit D levels (r= 0.40 p= 0.009. Our findings are in agreement with previous data, which suggest that factors other than serum Mg are more important in the regulation of PTH secretion in HD patients. A positive and strong association between serum Mg with 25-OH Vit D needs to be studied in greater detail.

  20. Serum biochemistry and morbidity among runners presenting for medical care after an Australian mountain ultramarathon.

    Science.gov (United States)

    Reid, Stephen A; King, M Jonathan

    2007-07-01

    To determine if exercise-associated hyponatremia (EAH) was a cause of morbidity among runners requiring medical care at an Australian mountain ultramarathon. Case series. Six Foot Track mountain ultramarathon, New South Wales, Australia, March 2006. Runners presenting to the medical facility. Serum biochemistry. No cases of exercise-associated hyponatremia were identified among 9 athletes (from 775 starters) who were treated with intravenous fluid therapy. Unwell runners had a mean serum (Na) of 143 mmol/L (range 138-147 mmol/L). All runners tested had elevated serum urea and creatinine concentrations. In this setting, EAH was not a significant cause of morbidity.

  1. Investigations of serum HPL during pregnancy using two different radioimmunoassays

    International Nuclear Information System (INIS)

    Stracke, H.

    1978-01-01

    The interassay investigations showed that it is absolutely necessary to standardize the HPL antisera as well as the standard sera, as it is otherwise impossible to compare and interpret the findings of different HPL radioimmunoassays. The investigations have shown that in addition to conventional clinical examinations and laboratory test methods (urine estriol determination, DHEAS-dehydroepiandrosterone sulphate test-, urine pregnandiol determination, and determination of heat-resisting alkaline serum phosphatase), HPL concentration determination is a parameter of the nutritive function of the placenta. (orig.) [de

  2. Serum markers thrombophilia in pregnant women with Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Vanessa Marcon de Oliveira

    Full Text Available Abstract Objectives: to determine the frequency of serum markers for hereditary and acquired thrombophilia and their association with pregnancy in women with Systemic Lupus Erythematosus (SLE. Methods: a case-control study was conducted among 25 pregnant women with SLE (study group and 32 pregnant women without known disease and with at least one previous pregnancy (control group. The presence of antiphospholipid antibodies and hereditary thrombophilia were examined in both groups. We used the y2 Test with Yates correction or Fisher's Exact Test to verify the associations and calculate the relative risk. Results: thrombophilia was present in 72.0% of pregnant women with SLE and in 6.0% of patients in the control group. A significant association was found between the presence of SLE and serum markers for hereditary thrombophilia / antiphospholipid antibodies (p<0.05. The relative risks for antiphospholipid antibodies were 13.20 (ICR95%= 1.81 - 96.46 in pregnant women with SLE, 7.26 (CI95%= 1.77 - 29.86 for the presence of serum markers of hereditary thrombophilia and 7.92 (CI95%= 2.62 - 3.94 for the presence of hereditary thrombophilia and/or antiphospholipid antibodies. Conclusions: the identification of markers for hereditary and/or acquired thrombophilia in pregnant women with lupus may be clinically useful to determine which patients have a higher risk of obstetric complications.

  3. Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL

    Directory of Open Access Journals (Sweden)

    Gurmukh Singh

    2015-04-01

    Full Text Available Objective: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. Methods: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a evidence of corrective action in patients with serum folate values 25.7 ng/mL. Results: The prevalence of serum folate levels, in patients, 25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate 60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL. Keywords: Serum folate, Prevalence of folate deficiency, Neural tube defects, Optimum serum folate level, Utility of folate testing

  4. SERUM PARAOXONASE ACTIVITY IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    Saritha Gadicherla

    2017-12-01

    Full Text Available BACKGROUND Serum paraoxonase is an enzyme synthesised in the liver. It is known to prevent atherosclerosis by inhibiting oxidation of lowdensity lipoprotein. Renal transplant recipients have increased tendency for developing atherosclerosis and cardiovascular disease. Reduced activity of serum paraoxonase contributes to accelerated atherosclerosis and increased cardiovascular complications in these patients. The aim of this study was to estimate serum paraoxonase activity in renal transplant recipients and compare it with healthy controls. MATERIALS AND METHODS 30 renal transplant recipients and 30 age and sex matched healthy controls were taken for the study. Serum paraoxonase activity, blood urea, serum creatinine and uric acid were estimated in these groups. The serum paraoxonase activity was correlated with urea, creatinine and uric acid levels. RESULTS Serum paraoxonase activity was reduced in renal transplant recipients compared to healthy controls. There was a negative correlation between paraoxonase activity and the levels of urea, creatinine and uric acid levels. CONCLUSION In this study, the paraoxonase activity was reduced in renal transplant recipients compared to controls. The increased cardiovascular disease in these patients could be due to reduced paraoxonase activity.

  5. Serum homocystein level in patients with scleroderma.

    Science.gov (United States)

    Nazarinia, Mohammadali; Shams, Mesbah; Kamali Sarvestani, Eskandar; Shenavande, Saeede; Khademalhosseini, Maryam; Khademalhosseini, Zeinab

    2013-01-01

    Systemic Sclerosis (SSc) is a systemic connective tissue disease. In this study, we compared the serum Homocystein (Hcy) level between patients with SSc and normal control group. The current study was conducted to determine whether serum Hcy levels are elevated in SSc patients and whether there is any correlation between Hcy levels and RP, Gastro intestinal and lung involvement. Forty one patients who fulfilled the diagnostic criteria for SSc (39 females and 5 males) and Forty four community-based healthy individuals (sex and age matched) were enrolled in to the study. Serum Hcy, vitamin B12, and folate levels were determined. Thirty three patients (70.45%) had GI involvement, twenty two patients (50%) had lung involvement and twenty seven patients (61.36%) had Raynaud's phenomena. Mean serum Hcy level in control group was 22.78 ± 6.018 μmol/L and in case group was 19.43 ± 7.205 μmol/L, shows that the serum Hcy level in control group was significantly higher than patients (P = 0.020). Serum Hcy level is significantly lower in SSc patients than in control group. There is no statistically significant correlation between serum Hcy level and organ involvements.

  6. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  7. Fasting serum glucose and glycosylated hemoglobin level in obesity.

    Science.gov (United States)

    Das, R K; Nessa, A; Hossain, M A; Siddiqui, N I; Hussain, M A

    2014-04-01

    Obesity is a condition in which the body fat stores are increased to an extent which impairs health and leads to serious health consequences. The amount of body fat is difficult to measure directly, and is usually determined from an indirect measure - the body mass index (BMI). Increased BMI in obese persons is directly associated with an increase in metabolic disease, such as type 2 diabetes mellitus. This Analytical cross sectional study was undertaken to assess the relation between obesity and glycemic control of body by measuring fasting serum glucose and glycosylated hemoglobin. This study was carried out in the Department of Physiology, Mymensingh Medical College, Mymensingh from 1st July 2011 to 30th June 2012 on 120 equally divided male and female persons within the age range of 25 to 55 years. Age more than 55 years and less than 25 years and diagnosed case of Hypothyroidism, Cushing's syndrome, polycystic ovary, Antipsychotic drug user and regular steroid users were excluded. Non probability purposive type of sampling technique was used for selecting the study subjects. Measurement of body mass index was done as per procedure. Fasting serum glucose was estimated by glucose oxidase method and Glycosylated hemoglobin by Boronate Affinity method. Statistical analysis was done by SPSS (version 17.0). Data were expressed as Mean±SE and statistical significance of difference among the groups were calculated by unpaired student's 't' test and Pearson's correlation coefficient tests were done as applicable. The Mean±SE of fasting serum glucose was significant at 1% level (P value obese group of BMI. There was no significant difference of glycosylated hemoglobin level between control and study groups. But there was positive correlation within each group. Fasting serum glucose also showed a bit stronger positive correlation with BMI. Both obese male and female persons showed higher levels of fasting serum glucose and glycosylated hemoglobin. The observed positive

  8. Serum Levels of Zinc, Copper and Their Carrier Proteins in Cattle with theileriosis

    Directory of Open Access Journals (Sweden)

    M Fartashvand

    2011-02-01

    Full Text Available In this study, 90 cattle with theileriosis and 90 healthy cattle were studied based on clinical and laboratory examination including parasitological and biochemical tests. Special biochemical kits were used for determination of zinc, copper, albumin, calcium, magnesium and ferrous levels in sera. Serum levels of transferin and ceruloplasmin were measured with ELISA and Sunderman & Nomoto method, respectively. The serum level of zinc was significantly decreased in cattle suffering from theileriosis (p

  9. Effect of Xylitol on Candida albicans resistance in serum (in vitro study

    Directory of Open Access Journals (Sweden)

    Ria Puspitawati

    2013-07-01

    Full Text Available Xylitol is reported to inhibit the growth of C. albicans. Objectives: Investigating serum factor role in inhibiting the growth of C. albicans and the effect of 1%, 5%, 10% xylitol on C. albicans resistance in serum in vitro. Methods: Identification of C. albicans (oral swab of candidiasis patient was conducted using CHROMAgar, confirmed by germ tube test. The cultures were serially diluted, inoculated in Saburoud Dextrose Broth (SDB contained 0% (control, 1%, 5%, or 10% xylitol, and kept for 3 or 7 days. These inoculations were then exposed to either active or inactive serum (Fetal Bovine Serum heated in 65ºC for 30 minutes for 2 hours in 37ºC. The colony forming unit (CFU of C. albicans in Saburoud Dextrose Agar (SDA were counted after 2 days. C. albicans ATCC 10231 strain was used as a comparison. One-way ANOVA with 0.05 was used. Results: After 3 days cultured in media with or without xylitol, the CFU of C. albicans exposed to active serum were significantly lower than those exposed to inactive serum (p=0.032. Although not statistically significant (p=0.689, increased concentration of xylitol lead to increased resistance of C. albicans in active serum. Only 7 day exposure of 10% xylitol resulted in significantly higher growth of C. albicans (p=0.034. No significant difference of C. albicans CFU in active or inactive serum (p=0.404. Conclusion: Serum factor has role in inhibiting C. albicans growth in vitro. Exposure of 1%, 5%, or 10% xylitol for 3 or 7 days has no significant effect on C. albicans resistance in serum.DOI: 10.14693/jdi.v16i2.98

  10. Genome-wide association study of serum selenium concentrations

    DEFF Research Database (Denmark)

    Gong, Jian; Hsu, Li; Harrison, Tabitha

    2013-01-01

    Selenium is an essential trace element and circulating selenium concentrations have been associated with a wide range of diseases. Candidate gene studies suggest that circulating selenium concentrations may be impacted by genetic variation; however, no study has comprehensively investigated...... this hypothesis. Therefore, we conducted a two-stage genome-wide association study to identify genetic variants associated with serum selenium concentrations in 1203 European descents from two cohorts: the Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening and the Women’s Health Initiative (WHI). We...... tested association between 2,474,333 single nucleotide polymorphisms (SNPs) and serum selenium concentrations using linear regression models. In the first stage (PLCO) 41 SNPs clustered in 15 regions had p

  11. Plasma catecholamine and serum gastrin concentrations during sham feeding

    DEFF Research Database (Denmark)

    Bekker, Carsten; Andersen, D; Kronborg, O

    1983-01-01

    Plasma adrenaline, plasma noradrenaline and serum gastrin concentrations were measured before and after sham feeding in eight patients with duodenal ulcer and in four normal subjects. No significant change in the concentrations was observed after sham feeding. In three patients with duodenal ulce...... groups. It is concluded that sympathetic nervous activity and serum gastrin concentrations are not influenced by sham feeding in contrast to the influence of insulin hypoglycemia....... an insulin test resulted in a 25-fold rise in plasma adrenaline. The ulcer patients showed significantly higher levels of plasma adrenaline and plasma noradrenaline than the normal subjects both before and after sham feeding, and this difference was probably not caused only by age difference in the two...

  12. Determination of serum digosin. A comparison between RIA and EIA

    Energy Technology Data Exchange (ETDEWEB)

    Spitz, J; Braun, J S; Schmidt, M [Krankenhausstiftung Bamberg (Germany, F.R.). Nuklearmedizinische Abt.; Abt fuer Labormedizin, Krankenhausstiftung Bamberg [Germany, F.R.

    1979-12-01

    The results of two radioimmunoassays (RIA, precipitating technique), of a homogenous (EMIT) and a heterogenous (ELISA) enzyme immunoassay (EIA) for ascertaining the amounts of digoxin showed a good correlation in precision and a reasonably AK satisfying correlation in the recovery. However, there was a clear discrepancy in the amounts of digoxin concentrate in the serum of patients. Only the RIA of Abbott and the EIA of Boehringer showed no significant differences. Particularly noticeable was the tendency towards lower values in the EMIT-technique as well as its liability to unspecific serum changes (lipaemia etc.), which often made the detection of digoxin impossible. The routine use of this technique appears problematic. The need for establishing one's own laboratory and test-specific therapeutical range is pointed out.

  13. Determination of serum digosin. A comparison between RIA and EIA

    International Nuclear Information System (INIS)

    Spitz, J.; Braun, J.S.; Schmidt, M.; Krankenhausstiftung Bamberg

    1979-01-01

    The results of two radioimmunoassays (RIA, precipitating technique), of a homogenous (EMIT) and a heterogenous (ELISA) enzyme immunoassay (EIA) for ascertaining the amounts of digoxin showed a good correlation in precision and a reasonably AK satisfying correlation in the recovery. However, there was a clear discrepancy in the amounts of digoxin concentrate in the serum of patients. Only the RIA of Abbott and the EIA of Boehringer showed no significant differences. Particularly noticeable was the tendency towards lower values in the EMIT-technique as well as its liability to unspecific serum changes (lipaemia etc.), which often made the detection of digoxin impossible. The routine use of this technique appears problematic. The need for establishing one's own laboratory and test-specific therapeutical range is pointed out. (orig.) [de

  14. Ascorbic acid interference in the measurement of serum biochemical parameters: in vivo and in vitro studies.

    Science.gov (United States)

    Martinello, Flávia; da Silva, Edson Luiz

    2006-04-01

    To investigate the negative interference of ascorbic acid in serum biochemical tests in relation to the dose of vitamin C intake and to the time of blood collection. Healthy volunteers (n = 18) consumed daily doses of vitamin C (0.25-4.0 g) for 1 week and serum parameters were assayed prior to the experiment and on the eighth day of consumption. Blood samples were collected 4, 12 and 24 h after vitamin C intake. Serum levels of ascorbic acid increased significantly after vitamin C ingestion inhibiting urate and total bilirubin tests 4 and 12 h after intake (P cholesterol tests. Addition of ascorbic acid to serum inhibited the urate test to a similar extent to that observed after vitamin C intake. However, after ingesting vitamin C, the interference for the bilirubin test was greater than that of the in vitro interference. Commonly taken doses of supplementary vitamin C interfered negatively with the serum urate test based on the Trinder method, and with bilirubin metabolism.

  15. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  16. Modeling Serum Creatinine in Septic ICU Patients

    DEFF Research Database (Denmark)

    De Gaetano, Andrea; Cortese, Giuliana; Pedersen, Morten Gram

    2004-01-01

    Serum creatinine is a metabolite assumed to be constantly produced by the normally functioning muscle mass and is a good measure for monitoring daily renal function in the intensive care unit (ICU). High serum creatinine levels or an abnormal departure from normal pre-disease basal levels....... The present work details the structure of a model describing observed creatinine serum concentration (CSC) variations, depending on the time-varying septic insult to renal function in ICU patients, as well as the estimation of its parameters. CSC determinations were routinely obtained from 12 patients...

  17. Leptin in first trimester pregnancy serum

    DEFF Research Database (Denmark)

    Hedley, Paula; Pihl, Kasper; Krebs, Lone

    2009-01-01

    and its relation to fetal growth disturbances were examined in this study. The study is a case-control study with 36 small-for-gestational-age (SGA) (pregnancies and 108 appropriate-for-gestational-age (AGA) (> or =5th percentile) pregnancies. The groups were matched by maternal age...... maternal BMI. There was no significant difference in maternal serum leptin concentrations between SGA and AGA pregnancies. In conclusion, SGA pregnancies are not associated with a lower maternal serum leptin concentration in first trimester. The maternal serum leptin concentration is largely determined...

  18. Evaluation of a Serum Lung Cancer Biomarker Panel.

    Science.gov (United States)

    Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria

    2018-01-01

    A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results.

  19. The value of peri-interventional procedure serum bile acid (TBA) detection in patients with primary liver cancer

    International Nuclear Information System (INIS)

    Fan Chen; Liu Yizhi

    2005-01-01

    Objective: To investigate the clinical value of peri-interventional procedure serum bile acid (TBA) detection in patients with primary liver cancer. Methods: The serum TBA was examined peri-operatively in 160 patients with primary liver cancer for testing the correlations between TBA, liver function, the degree of hepatocirrhosis, interventional therapy method and hepatic failure. Results: The preoperative mean value of serum TBA increased significantly in comparing with that of the control group (P<0.01). The preoperative value of serum TBA in different Child grading patients with primary liver cancer were different significantly (P<0.01), Child A< Child B< Child C, the increased degree of serum TBA corresponded with Child grading of the liver function and the cirrhotic degree of liver. In patients with liver function of Child B and C, the postoperative mean values of serum TBA in different interventional therapy methods were different significantly (P<0.01). Comparing with that of the patients without hepatic failure, the postoperative value of serum TBA in the patients with hepatic failure increased significantly (P<0.01). Conclusions: The value of serum TBA can sensitively and accurately reflect liver reserve ability and damage degree of peri-interventional procedure liver function. Hepatic failure can be detected in time and the prognosis of the patients with primary liver cancer can be predicted by testing the value of serum TBA continually. (authors)

  20. Acute Alcohol Consumption Elevates Serum Bilirubin, an Endogenous Antioxidant

    Science.gov (United States)

    O’Malley, Stephanie S.; Gueorguieva, Ralitza; Wu, Ran; Jatlow, Peter I.

    2015-01-01

    Background Moderate alcohol consumption has been associated with both negative and favorable effects on health. The mechanisms responsible for reported favorable effects remain unclear. Higher (not necessarily elevated) concentrations of serum bilirubin, an antioxidant, have also been associated with reduced risk of cardiovascular disease and all-cause mortality. This study tests the hypothesis that single dose alcohol consumption elevates bilirubin providing a potential link between these observations. Methods 18 healthy individuals (8 cigarette smokers) were administered alcohol, calibrated to achieve blood concentrations of 20, 80 and 120 mg/dL, in random order in 3 laboratory sessions separated by a week. Each session was preceded by and followed by 5–7 days of alcohol abstinence. Serum bilirubin was measured at 7:45 am prior to drinking, at 2 pm, and at 7:45 the next morning. Mixed effects regression models compared baseline and 24 hr. post-drinking bilirubin concentrations. Results Total serum bilirubin (sum of indirect and direct) concentration increased significantly after drinking from baseline to 24 hours in non-smokers (from Mean=0.38, SD=0.24 to Mean=0.51 SD=0.30, F(1, 32.2) =24.24, pbilirubin concentration and the ratio of indirect (unconjugated) to direct (conjugated) bilirubin also increased significantly. Conclusions Alcohol consumption leads to increases in serum bilirubin in nonsmokers. Considering the antioxidant properties of bilirubin, our findings suggest one possible mechanism for the reported association between alcohol consumption and reduced risk of some disorders that could be tested in future longitudinal studies. PMID:25707709

  1. Relation between Serum Ferritin and Iron Parameters with Preeclampsia

    Directory of Open Access Journals (Sweden)

    Robabeh Taheripanah

    2007-06-01

    Full Text Available Objective: Preeclampsia is one of the most important complications of pregnancy that is associated with increased morbidity and mortality. The aim of this study was to investigate the relation between serum iron status and ferritin with pre-eclampsia. Materials and Methods: This case control study evaluated 33 preeclamptic patients and 33 normal pregnant women before parturition in Imam Hossein hospital, from March 2003 till March 2004. Anemia, diabetes and multiple pregnancies were excluded from the study. Blood samples were taken before delivery and patients with HELLP syndrome were considered separately.  Data were analyzed using the SPSS software and P value <0.05 was considered statistically significant. T-test, chi-square and Fisher exact test were used.  Results: The mean of serum iron level in case and control group was 79.9±32.4µg/dl and 88.6±40.8 µg/dl, respectively (NS. TIBC was 443.4±55.0 µmol/l and 383.7±63.6 µmol/l in normal patients and preeclamptics respectively (P = 0.002. Mean serum ferritin was 32.1±16.2 ng/dl in control group and 123.8±46.1 ng/dl in preeclamptics (P<0.001. No meaningful relation was observed between hematocrit, ferritin and iron. Conclusions: Ferritin increases and TIBC decreases in preeclampsia regardless of hepatic function. It seems that elevated serum ferritin (as an oxidative stress can accelerate vascular damage. So, routine iron supplementation in preeclamptic women is questationable.

  2. Association of Mood Disorders with Serum Zinc Concentrations in Adolescent Female Students.

    Science.gov (United States)

    Tahmasebi, Kobra; Amani, Reza; Nazari, Zahra; Ahmadi, Kambiz; Moazzen, Sara; Mostafavi, Seyed-Ali

    2017-08-01

    Among various factors influencing mood disorders, the impact of micronutrient deficiencies has attracted a great attention. Zinc deficiency is considered to play a crucial role in the onset and progression of mood disorders in different stages of life. The main objective of this study was to assess the correlation between serum zinc levels and mood disorders in high school female students. This cross-sectional study was conducted on a random sample of 100 representative high school female students. The participants completed 24-h food recall questionnaires to assess the daily zinc intakes. Serum zinc status was assessed using flame atomic absorption spectrometry, and zinc deficiency was defined accordingly. Mood disorders were estimated by calculating the sum of two test scores including Beck's depression inventory (BDI) and hospital anxiety depression scale (HADS) tests. General linear model (GLM) and Pearson's regression test were applied to show the correlation of serum zinc levels and mood disorder scores and the correlation between zinc serum levels and BDI scores, respectively. Dietary zinc intake was higher in subjects with normal zinc concentrations than that of zinc-deficient group (p = 0.001). Serum zinc levels were inversely correlated with BDI and HADS scores (p zinc levels led to 0.3 and 0.01 decrease in depression and anxiety scores, respectively (p zinc levels were inversely correlated with mood disorders including depression and anxiety in adolescent female students. Increasing serum levels of zinc in female students could improve their mood disorders.

  3. Maternal serum leptin concentration in gestational diabetes

    Directory of Open Access Journals (Sweden)

    Sedigheh Soheilykhah

    2011-06-01

    Conclusion: Our data showed that serum leptin level was higher in GDM and had a positive correlation with insulin resistance. Our findings suggest that high leptin levels might be a risk factor for GDM and IGT in pregnant women.

  4. Autologous serum therapy in chronic urticaria

    Directory of Open Access Journals (Sweden)

    Sharmila Patil

    2013-01-01

    Full Text Available Autologous serum therapy is a promising therapy for treatment resistant urticaria. This is useful in developing countries as this is economical option. Minimum instruments like centrifuge, syringe and needles are required for the procedure.

  5. Relationship between some serum electrolytes and ...

    African Journals Online (AJOL)

    ADEYEYE

    2014-02-03

    Feb 3, 2014 ... The effect of Trypanosoma brucei infection on changes in concentration of some serum electrolytes and the ... the modulatory responses of the autonomic nervous system ..... Concurrent hyponatremia and hypocalcemia have.

  6. Serum Prolactin in Diagnosis of Epileptic Seizures

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2005-09-01

    Full Text Available The results of studies in databases and references concerning serum prolactin levels (PRL in patients with suspected seizures were rated for quality and analyzed by members of the Therapeutics Subcommittee of the American Academy of Neurology.

  7. Alteration of serum adropin level in preeclampsia.

    Science.gov (United States)

    Wang, Huihua; Gao, Bo; Wu, Zaigui; Wang, Hanzhi; Dong, Minyue

    2017-04-01

    To clarify the alterations in serum adropin and preptin concentrations in preeclampsia, we determined serum adropin and preptin levels in 29 women with normal pregnancy and 32 women with preeclampsia. We found that maternal age, body mass index and fetal gender were not significantly different between two groups; however, blood pressure, gestational age and neonatal birth weight were significantly different. Serum adropin levels were significantly increased in women with preeclampsia compared with those with normal pregnancy but there were no significant differences in preptin levels. An increase in maternal serum adropin level was found in preeclampsia, and this may be a compensation for pregnancy complicated with preeclampsia. Copyright © 2017 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  8. Isocyanate test antigens

    International Nuclear Information System (INIS)

    Karol, M.H.; Alarie, Y.C.

    1980-01-01

    A test antigen for detecting antibodies to a diisocyanate comprises the reaction product of a protein and a monoisocyanate derived from the same radical as the diisocyanate. The diisocyanates most usually encountered and therefore calling for antibody detection are those of toluene, hexamethylene, methylene, isophorone and naphthylene. The preferred protein is human serum albumin. (author)

  9. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    Science.gov (United States)

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  10. Smoking Discriminately Changes the Serum Active and Non-Active Forms of Vitamin B12.

    Science.gov (United States)

    Shekoohi, Niloofar; Javanbakht, Mohammad Hassan; Sohrabi, Marjan; Zarei, Mahnaz; Mohammadi, Hamed; Djalali, Mahmoud

    2017-06-01

    Smoking may modify the appetite, and consequently affect nutrient intake and serum micronutrients. The effect of smoking on vitamin B12 status has been considered in several studies. The research proposed that organic nitrites, nitro oxide, cyanides, and isocyanides of cigarette smoke interfere with vitamin B12 metabolism, and convert it to inactive forms. This research was carried out to determine the serum level of active and inactive forms of vitamin B12 in male smokers in comparison with male nonsmokers. This is a case-control study, in which the participants were 85 male smokers and 85 male nonsmokers. The serum levels of total and active form of vitamin B12 were measured. Dietary intake was recorded by a quantitative food frequency questionnaire and one-day 24-hour dietary recall method. Independent two sample T test was used to compare quantitative variables between the case and control groups. The serum level of total vitamin B12 was not significantly different between two groups, but serum level of active form of vitamin B12 in the smoking group was significantly lower than non-smoking group (Psmokers in the Iranian community. The results of this study identified that serum level of total vitamin B12 might be not different between smoking and non-smoking people, but the function of this vitamin is disturbed in the body of smokers through the reduction of serum level of active form of vitamin B12.

  11. Serum YKL-40 independently predicts outcome after transcatheter arterial chemoembolization of hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Cheng-Bao Zhu

    Full Text Available Transcatheter arterial chemoembolization (TACE is the most widely used treatment option for unresectable hepatocellular carcinoma (HCC. Elevated serum YKL-40 level has been shown to predict poor prognosis in HCC patients undergoing resection. This study was designed to validate the prognostic significance of serum YKL-40 in patients with HCC undergoing TACE treatment.Serum YKL-40 level was determined by enzyme-linked immunosorbent assay. Overall survival (OS was evaluated with the Kaplan-Meier method and compared by the log-rank test. Multivariate study with Cox proportional hazard model was used to evaluate independent prognostic variables of OS.The median pretreatment serum YKL-40 in HCC patients with was significantly higher than that in healthy controls (P<0.001. The YKL-40 could predict survival precisely either in a dichotomized or continuous fashion (P<0.001 and P = 0.001, respectively. Multivariate Cox regression analysis indicated that serum YKL-40 was an independent prognostic factor for OS in HCC patients (P = 0.001. In further stratified analyses, YKL-40 could discriminate the outcomes of patients with low and high alpha-fetoprotein (AFP level (P = 0.006 and 0.016, respectively. Furthermore, the combination of serum YKL-40 and AFP had more capacity to predict patients' outcomes.Serum YKL-40 was demonstrated to be an independent prognostic biomarker in HCC patients treated with TACE. Our results need confirmation in an independent study.

  12. Serum γ-Glutamyl Transferase Is Inversely Associated with Bone Mineral Density Independently of Alcohol Consumption

    Directory of Open Access Journals (Sweden)

    Han Seok Choi

    2016-03-01

    Full Text Available Backgroundγ-Glutamyl transferase (GGT is a well-known marker of chronic alcohol consumption or hepatobiliary diseases. A number of studies have demonstrated that serum levels of GGT are independently associated with cardiovascular and metabolic disorders. The purpose of this study was to test if serum GGT levels are associated with bone mineral density (BMD in Korean adults.MethodsA total of 462 subjects (289 men and 173 women, who visited Severance Hospital for medical checkup, were included in this study. BMD was measured using dual energy X-ray absorptiometry. Cross-sectional association between serum GGT and BMD was evaluated.ResultsAs serum GGT levels increased from the lowest tertile (tertile 1 to the highest tertile (tertile 3, BMD decreased after adjusting for confounders such as age, body mass index, amount of alcohol consumed, smoking, regular exercise, postmenopausal state (in women, hypertension, diabetes mellitus, and hypercholesterolemia. A multiple linear regression analysis showed a negative association between log-transformed serum GGT levels and BMD. In a multiple logistic regression analysis, tertile 3 of serum GGT level was associated with an increased risk for low bone mass compared to tertile 1 (odds ratio, 2.271; 95% confidence interval, 1.340 to 3.850; P=0.002.ConclusionSerum GGT level was inversely associated with BMD in Korean adults. Further study is necessary to fully elucidate the mechanism of the inverse relationship.

  13. Diagnostic Value of Serum Adenosine Deaminase (ADA) Level for Pulmonary Tuberculosis.

    Science.gov (United States)

    Salmanzadeh, Shokrollah; Tavakkol, Heshmatollah; Bavieh, Khalid; Alavi, Seyed Mohammad

    2015-03-01

    Diagnosis of tuberculosis (TB) is not always easy, thus employing methods with a short duration and acceptable sensitivity and specificity is necessary to diagnose TB. The aim of this study was to investigate the diagnostic value of serum adenosine deaminase (ADA) level for diagnosis of pulmonary tuberculosis. A total of 160 sex and age-matched subjects were included in this study, and were divided to four groups; forty patients with pulmonary tuberculosis (PTB) diagnosed based on the national TB program (NTP), forty patients with non-tuberculosis bacterial pneumonia, forty patients with lung cancer and forty people who were healthy in every respect. Serum adenosine deaminase activity in patients of each group was measured by the Giusti and Galanti calorimetry method using a commercial kit (Diazyme, USA). The ANOVA analysis was used to compare groups for quantitative variables. Mean serum ADA level in the PTB group was clearly higher than the mean serum ADA in the other three groups. Mean serum ADA was 26 IU/L in PTB patients, 19.48 IU/L in patients with pneumonia, 15.8 IU/L in patients with lung cancer, and 10.7 IU/L in the control group (P ADA in patients with PTB sensitivity and specificity was defined as 35% and 91%, respectively. Serum ADA activity with high specificity percentage may be a useful alternative test in restricted resource areas to rule out diagnosis of PTB. However, serum ADA activity is not a useful tool for TB diagnosis.

  14. Hyperandrogenemia predicts metabolic phenotype in polycystic ovary syndrome: the utility of serum androstenedione.

    Science.gov (United States)

    O'Reilly, Michael W; Taylor, Angela E; Crabtree, Nicola J; Hughes, Beverly A; Capper, Farfia; Crowley, Rachel K; Stewart, Paul M; Tomlinson, Jeremy W; Arlt, Wiebke

    2014-03-01

    Polycystic ovary syndrome (PCOS) is a triad of anovulation, insulin resistance, and hyperandrogenism. Androgen excess may correlate with metabolic risk and PCOS consensus criteria define androgen excess on the basis of serum T. Here we studied the utility of the androgen precursor serum androstenedione (A) in conjunction with serum T for predicting metabolic dysfunction in PCOS. Eighty-six PCOS patients fulfilling Rotterdam diagnostic consensus criteria and 43 age- and body mass index-matched controls underwent measurement of serum androgens by tandem mass spectrometry and an oral glucose tolerance test with homeostatic model assessment of insulin resistance and insulin sensitivity index calculation. We analyzed 24-hour urine androgen excretion by gas chromatography/mass spectrometry. PCOS patients had higher levels of serum androgens and urinary androgen metabolites than controls (all P PCOS cohort, both serum A and T were positively correlated with the free androgen index (T × 100/SHBG) and total androgen metabolite excretion (all P androgen excretion than NA/NT (P androgen phenotype (NA/NT, 0%; HA/NT, 14%; HA/HT, 25%, P = .03). Simultaneous measurement of serum T and A represents a useful tool for predicting metabolic risk in PCOS women. HA levels are a sensitive indicator of PCOS-related androgen excess.

  15. Serum Bisphenol A Level in Boys with Cryptorchidism: A Step to Male Infertility?

    Directory of Open Access Journals (Sweden)

    Marta Diana Komarowska

    2015-01-01

    Full Text Available Cryptorchidism is the most common congenital birth defect in boys and affects about 2–4% full-term male neonates. Its etiology is multifactorial. Purpose. To evaluate the serum bisphenol A (BPA levels in boys with cryptorchidism and healthy boys and to assess the risk of environmental exposure to BPA using the authors’ questionnaire. The data were acquired from a study on boys with cryptorchidism (n=98 and a control group (n=57. Prior to surgery, all patients had BPA serum levels evaluated. The size, position, rigidity of the testis, and abnormality of the epididymis of the undescended testis were assessed. Parents also completed a questionnaire on the risks of exposure to BPA in everyday life. Results. The testes in both groups were similar in size. The turgor of the undescended testis in the group of boys with cryptorchidism was decreased. Free serum BPA level in cryptorchid boys and in the control group was not statistically significant (p>0.05. The conjugated serum BPA level in cryptorchid boys and in the control group was statistically significant (p≤0.05. Total serum BPA level in cryptorchid boys and in the control group was statistically significant (p<0.05. Serum total BPA level was related with a positive answer about problems with conception (p<0.02. Conclusion. Our study indicated that high serum BPA was associated with cryptorchidism.

  16. Serum homocysteine levels in cerebrovascular accidents

    OpenAIRE

    Zongte, Zolianthanga; Shaini, L.; Debbarma, Asis; Singh, Th Bhimo; Devi, S. Bilasini; Singh, W. Gyaneshwar

    2008-01-01

    Hyperhomocysteinemia has been considered an independent risk factor in the development of stroke. The present study was undertaken to evaluate serum homocysteine levels in patients with cerebrovascular accidents among the Manipuri population and to compare with the normal cases. Ninety-three cerebrovascular accident cases admitted in the hospital were enrolled for the study and twenty-seven age and sex matched individuals free from cerebrovascular diseases were taken as control group. Serum h...

  17. Serum Soluble Corin is Decreased in Stroke.

    Science.gov (United States)

    Peng, Hao; Zhu, Fangfang; Shi, Jijun; Han, Xiujie; Zhou, Dan; Liu, Yan; Zhi, Zhongwen; Zhang, Fuding; Shen, Yun; Ma, Juanjuan; Song, Yulin; Hu, Weidong

    2015-07-01

    Soluble corin was decreased in coronary heart disease. Given the connections between cardiac dysfunction and stroke, circulating corin might be a candidate marker of stroke risk. However, the association between circulating corin and stroke has not yet been studied in humans. Here, we aimed to examine the association in patients wtith stroke and community-based healthy controls. Four hundred eighty-one patients with ischemic stroke, 116 patients with hemorrhagic stroke, and 2498 healthy controls were studied. Serum soluble corin and some conventional risk factors of stroke were examined. Because circulating corin was reported to be varied between men and women, the association between serum soluble corin and stroke was evaluated in men and women, respectively. Patients with ischemic and hemorrhagic stroke had a significantly lower level of serum soluble corin than healthy controls in men and women (all P values, stroke than men in the highest quartile. Women in the lowest quartile of serum soluble corin were also more likely to have ischemic (OR, 3.10; 95% confidence interval, 1.76-5.44) and hemorrhagic (OR, 8.54; 95% confidence interval, 2.35-31.02) stroke than women in the highest quartile. ORs of ischemic and hemorrhagic stroke were significantly increased with the decreasing levels of serum soluble corin in men and women (all P values for trend, stroke compared with healthy controls. Our findings raise the possibility that serum soluble corin may have a pathogenic role in stroke. © 2015 American Heart Association, Inc.

  18. Evaluation of serum lipids and lipoproteins as prognosticators in leukoplakia.

    Science.gov (United States)

    Ganavi, B S; Patil, Shankargouda; Rao, Roopa S

    2014-05-01

    Oral cancer is the 8th most common cancer worldwide. Squamous cell carcinomas constitute 94% of all oral malignancies and are often preceded by leukoplakia. Despite many adjunctive techniques to monitor transformation of leukoplakia to oral squamous cell carcinoma (OSCC), the mortality rate is on the rise. Incidentally, patients diagnosed with oral potentially malignant disorders (OPMDs) and oral cancers manifest with low choles-terol levels. Given a thought, hypolipidemia may be a useful adjunctive tool as it reflects the initial changes within the neo-plastic cells, thus giving a red alert in malignant transformation of leukoplakia at the earlier stage. To evaluate the feasibility of serum lipid profile as an adjunct early marker for malignant transformation of leukoplakia to OSCC. To estimate the serum cholesterol, triglycerides and lipoprotein (HDL, LDL, VLDL) levels in patients with leukoplakia, OSCC and age matched healthy control group. To compare the serum cholesterol, triglycerides and lipoprotein levels between patients of leukoplakia, OSCC and age matched healthy control group. The study group comprised of selected 30 individuals which included 10 each of histopathologically confirmed OSCC, leukoplakia and healthy controls. A written consent was taken from all of them, and a thorough case history was recorded and then venous blood was collected 12 hours post fasting and centrifuged. The serum cholesterol, triglycerides and HDL were estimated by enzymatic and colorimetric methods using commercially available kits--Roche/ Hitachi cobas systems. Chemistry assay QC procured from Bio-Rad was used as control. VLDL and LDL were derived from these values. Results were statistically analyzed using ANOVA and post hoc Tukey Test. Oral squamous cell carcinoma patients demonstrated significantly lower mean serum cholesterol level (151.60 mg/dl) than the control group (183.70 mg/dl). The mean cholesterol level in leukoplakia patients (173.90 mg/dl) was lower than that

  19. Technetium-99m-Labeled Autologous Serum Albumin: A Personal-Exclusive Source of Serum Component

    OpenAIRE

    Wang, Yuh-Feng; Chen, Yi-Chun; Li, Dian-Kun; Chuang, Mei-Hua

    2011-01-01

    Technetium-99m human serum albumin (99mTc-HSA) is an important radiopharmaceutical required in nuclear medicine studies. However, the risk of transfusion-transmitted infection remains a major safety concern. Autopreparation of serum component acquired from patient provides a “personal-exclusive” source for radiolabeling. This paper is to evaluate the practicality of on-site elusion and subsequent radiolabeling efficacy for serum albumin. Results showed that the autologous elute contained more...

  20. Relationship between Serum Iron Profile and Blood Groups among the Voluntary Blood Donors of Bangladesh.

    Science.gov (United States)

    Hoque, M M; Adnan, S D; Karim, S; Al-Mamun, M A; Faruki, M A; Islam, K; Nandy, S

    2016-04-01

    Blood donation results in a substantial iron loss and subsequent mobilization from body stores. Chronic iron deficiency is a well-recognized complication of regular blood donation. The present study conducted to compare the level of serum ferritin, serum iron, total iron binding capacity (TIBC) and percentage transferrin saturation in different ABO and Rhesus type blood groups among the voluntary blood donors of Bangladesh. The present prospective study included 100 healthy voluntary donors attending at Department of Blood Transfusion, Dhaka Medical College, Dhaka between the periods of July 2013 to Jun 2014. From each donor 10mL venous blood sample was taken and divided into heparinized and non-heparinized tubes for determination of hemoglobin (Hb), hematocrit (Hct), serum iron (SI), total iron binding capacity (TIBC) and serum ferritin by standard laboratory methods. Percentage of transferrin saturation (TS) calculated from serum iron and TIBC. Data were analyzed with SPSS (version 16) software and comparisons between groups were made using student's t-test and one way ANOVA. In the present study mean±SD of age of the respondents was 27.2±6.5 years with a range of 18 to 49 years and 81.0% were male and 19.0% were female. Among the donors 18.0% had blood group A, 35.0% had blood group B, 14.0% had blood group AB and 33.0% had blood group O. Among the donors 91.0% had rhesus positive and 9.0% had rhesus negative. Donors with blood group O had lowest haemoglobin, serum iron and transferring saturation levels. Donors with blood group A had highest TIBC level. Donors with blood group B had lowest serum ferritin level. An independent samples 't' test showed statistically significant difference in serum ferritin and percentage transferrin saturation between blood group AB and blood group O and in percentage transferrin saturation between blood group B and blood group O. One way ANOVA showed that there is no significant difference in haemoglobin, serum iron, serum

  1. Serum cystatin C level is associated with locomotive syndrome risk and can be an early predictor in community-living people: The Yakumo study.

    Science.gov (United States)

    Tanaka, Satoshi; Ando, Kei; Kobayashi, Kazuyoshi; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Machino, Masaaki; Ota, Kyotaro; Seki, Taisuke; Suzuki, Koji; Nishida, Yoshihiro; Ishiguro, Naoki; Hasegawa, Yukiharu; Imagama, Shiro

    2018-03-02

    The locomotive syndrome (LS) risk has been recently proposed as a criterion for evaluating physical ability. Serum cystatin C level is an early renal function marker and a cardiovascular disease predictor. This study aimed to evaluate the relationship between serum cystatin C level and LS risk. We enrolled 54 participants and conducted the two-step test, stand-up test, 25-question geriatric locomotive function scale, LS risk test, Timed Up and Go test, back muscle strength, grip strength, blood test and serum cystatin C level measurement. A comparative study was conducted in participants with and without LS risk and in subgroups aged C level in subgroups aged C level for LS risk was 0.824. The serum cystatin C level is significantly related to LS risk and can be an early predictor. In middle-aged and elderly people with high serum cystatin C levels, it is strongly recommended to enforce LS risk test and intervention.

  2. Serum concentrations of haptoglobin and serum amyloid A in water buffaloes (Bubalus bubalis with abomasal ulcer

    Directory of Open Access Journals (Sweden)

    Javad Tajik

    2012-09-01

    Full Text Available To evaluate the serum concentrations of haptoglobin (Hp and serum amyloid A (SAA in water buffaloes with abomasal ulcers, the abomasums of 100 randomly selected water buffaloes were examined after slaughter. Type I abomasal ulcers were found in 56 out of 100 buffaloes. Serum concentrations of Hp and SAA were measured. There was no significant difference between affected and non-affected buffaloes in the serum concentrations of Hp and SAA. The serum concentrations of Hp and SAA had no significant correlation with age and the serum SAA revealed no significant correlation with the number of abomasal ulcers. A significant correlation was found between the serum Hp and the number of abomasal ulcers (r =0.29, p = 0.04. There was no significant difference in the serum concentrations of Hp and SAA between buffaloes with different ulcer locations in the abomasums. Although more work on a larger number of animals is required in this area, it seems that the measurement of the serum Hp can be used to predict the abundance of type I abomasal ulcers.

  3. Comparison of serum bilirubin estimation with transcutaneous bilirubinometry in neonates

    International Nuclear Information System (INIS)

    Waqar, T.; Ahmad, Z.; Ali, A.

    2010-01-01

    Objective: To assess usefulness of Minolta Air shield transcutaneous bilirubinometer by comparing bilirubin values obtained by transcutaneous jaundice meter with serum bilirubin estimation. Design: Analytical cross sectional study. Place and duration: NICU Military Hospital Rawalpindi Pakistan Jun 2002 to May 2005. Subjects and Methods: One hundred and fifty neonates admitted to NICU because of visible jaundice were included in the study. Serum was sent to laboratory for total bilirubin estimation. At the same time bilirubin was also checked by a Jaundice Meter. Data was tabulated and t-test applied to compare the two values. Results: One hundred and fifty paired estimations were performed. The transcutaneous bilirubin values ranged from 8.0 mg/dl to 20.4 mg/dl. While serum bilirubin by jaundice meter values ranged between 5.3 mg/dl and 26.0 mg/dl. A Scatter diagram was plotted. It showed a correlation coefficient of 0.78. Conclusion: Bilirubin values obtained by transcutaneous bilirubin meter were not significantly different from laboratory values thus proving the fact that transcutaneous bilirubinometer is a useful device to measure bilirubin. (author)

  4. Serum bilirubin and the risk of rheumatoid arthritis.

    Science.gov (United States)

    Juping, Du; Yuan, Yuan; Shiyong, Chen; Jun, Li; Xiuxiu, Zhou; Haijian, Ying; Jianfeng, Shi; Bo, Shen

    2017-11-01

    Oxidative stress and immune imbalance play an important role in the pathogenesis of rheumatoid arthritis (RA). Bilirubin is a powerful antioxidant and also regarded as immunomodulator. Increased evidence shows that bilirubin should be a protective factor for autoimmune disease. However, the relationship between bilirubin and RA remain unclear. We analyzed serum bilirubin levels and other laboratory and clinical data in 130 RA patients (35 patients without any complications), 81 osteoarthritis (OA) patients and 96 healthy controls. Binary logistic regression adjusted by age and gender revealed that the levels of serum total, indirect bilirubin were significantly lower in RA patients, when compared with healthy controls (P=.015, OR=0.767, 95% CI=0.619-0.951; P=.010, OR=0.664, 95% CI=0.487-0.906, respectively) or OA patients (P=.000, OR=0.763, 95% CI=0.661-0.882; P=.000, OR=0.656, 95% CI=0.532-0.808, respectively). A reduced trend of levels of bilirubin has been detected along with increased disease activity, despite with no significance (P>.05). Spearman rank test further demonstrated that IgG and ESR were negative associated with total, indirect bilirubin, and albumin, prealbumin, APOA, HDL-C were positively associated with bilirubin. In conclusion, the levels of serum bilirubins were decreased in RA, and decreased levels could be associated with IgG, albumin and inflammatory marker ESR. © 2017 Wiley Periodicals, Inc.

  5. Assessment of serum ferritin levels in thalassemia and non-thalassemia patients presented with anemia

    Directory of Open Access Journals (Sweden)

    Mohammed Mahdi Abdulomohsin AL-Zubaidi

    2015-01-01

    Objectives: The aim of this study was to assess serum ferritin levels in B-thalassemia patients, and to compare it with non-thalassemic anemia and healthy control. Materials and methods : A prospective cross sectional study conducted at Thalassemia Center in Ibn Al- Baladi Hospital for Children and Women during the period from1st February to 30th May 2014 during their attendance to out-patient clinic. A total .number of 101 patients complaining of anemia (51 patients with thalassemia, 50 with non-thalassemia in addition to 50 healthy subjects considered as control. All patients were tested for Serum ferritin levels and all results were obtained through automated quantitative test for use Vidas machine Results : The mean serum ferritin levels in cases of thalassemia was 9542 ± 782 ng/ml while serum ferritin levels in control sample was 138 ± 323 ng/ml in male and 28 ± 108 ng/ml in female . in patients with non-thalassemia anemia, the levels of serum ferritin was 1 ± 80 ng/ml. Age of all patients in this study ranged from 3day-9year .the age of thalassemia patients ranged from 1-6 year and p-value was(0.23 while the age of patients with non-thalassemia anemia was 1-5 year and p-value was (0.11. Conclusion: This study confirm that serum ferritin is high in patients wih thalassemia than non thalassemia.

  6. Effects of Bariatric Surgery on Serum Bile Acid Composition and Conjugation in a Diabetic Rat Model.

    Science.gov (United States)

    Wu, Qunzheng; Zhang, Xiang; Zhong, Mingwei; Han, Haifeng; Liu, Shaozhuang; Liu, Teng; Wei, Meng; Guo, Wei; Xie, Haibin; Hu, Sanyuan; Zhang, Guangyong

    2016-10-01

    Serum bile acids (BAs) are elevated following bariatric surgery and have emerged as a potential glucose-lowering beneficial factor. The change of BA components and its underlying mechanisms may be of great significance during bariatric surgery. The aim of this study is to investigate the effects of different bariatric procedures on serum BA composition and explore the potential mechanisms using a diabetic rat model. Duodenal-jejunal bypass (DJB), sleeve gastrectomy (SG), and sham operation were performed in diabetic rats induced by high-fat diet (HFD) and streptozotocin (STZ). Body weight, food intake, oral glucose tolerance test (OGTT), and insulin tolerance test (ITT) were measured at indicated time points. Serum BAs composition and the expression of cholesterol 7α hydroxylase (CYP7A1), bile acid: CoA synthase (BACS) and bile acid-CoA: amino acid N-acyltransferase (BAAT) at both transcriptional and protein levels in the liver were evaluated at 12 weeks postoperatively. Compared with sham group, DJB and SG both achieved rapid and sustained improvements in glucose tolerance and insulin sensitivity. They also resulted in increased serum BAs, especially the taurine-conjugated BAs by elevated conjugation. No obvious difference was detected between DJB and SG except that SG achieved decreased weight gain and food intake. The preferentially elevated serum taurine-conjugated BAs were similar after different bariatric surgeries, and the enhanced conjugation of BAs in the liver might account for the changed serum BAs profiles.

  7. Study on the serum prolactin (PRL) level in post-menopausal women

    International Nuclear Information System (INIS)

    Li Wenqi; Li Xin; Zhou Jiwen; Zhou Zhengli

    2004-01-01

    Objective: To explore the clinical value of determination of serum PRL levels inpost-menopausal women. Methods: Serum PRL levels were determined with RIA in 596 post-menopausal women (age 45-59, mean 55). Results: The normal range of serum PRL level in this laboratory was 0-30 ng/ml. Among the 596 women tested, 77(13%) had their PRL levels above 30 ng/ml. Further investigation with CT and/or MRI revealed presence of micro-pituitary-adenoma in 31 of the Symptoms of menopausal syndrome and osteoporosis were much more severe in women with hyperprolactinemia then in those without. Conclusion: As hyperprolactinemia might be a high risk factor for development of breast cancer, hormone replacement therapy (HRT) in menopausal women with hyperprolactinemia should be applied very cautiously, even withheld at all. Determination of serum prolactin levels in post-menopausal women is of practical clinical value. (authors)

  8. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  9. New Parvovirus Associated with Serum Hepatitis in Horses after Inoculation of Common Biological Product.

    Science.gov (United States)

    Divers, Thomas J; Tennant, Bud C; Kumar, Arvind; McDonough, Sean; Cullen, John; Bhuva, Nishit; Jain, Komal; Chauhan, Lokendra Singh; Scheel, Troels Kasper Høyer; Lipkin, W Ian; Laverack, Melissa; Trivedi, Sheetal; Srinivasa, Satyapramod; Beard, Laurie; Rice, Charles M; Burbelo, Peter D; Renshaw, Randall W; Dubovi, Edward; Kapoor, Amit

    2018-02-01

    Equine serum hepatitis (i.e., Theiler's disease) is a serious and often life-threatening disease of unknown etiology that affects horses. A horse in Nebraska, USA, with serum hepatitis died 65 days after treatment with equine-origin tetanus antitoxin. We identified an unknown parvovirus in serum and liver of the dead horse and in the administered antitoxin. The equine parvovirus-hepatitis (EqPV-H) shares horses using a tetanus antitoxin contaminated with EqPV-H. Viremia developed, the horses seroconverted, and acute hepatitis developed that was confirmed by clinical, biochemical, and histopathologic testing. We also determined that EqPV-H is an endemic infection because, in a cohort of 100 clinically normal adult horses, 13 were viremic and 15 were seropositive. We identified a new virus associated with equine serum hepatitis and confirmed its pathogenicity and transmissibility through contaminated biological products.

  10. Measurement of serum type III procollagen aminopeptide with RIA-gnost PIIIP coated tube

    International Nuclear Information System (INIS)

    Maruyama, Katsuya; Takagi, Toshikazu; Okazaki, Isao

    1992-01-01

    In 55 patients with various alcoholic liver diseases, serum type III procollagen aminopeptide (PIIIP) was measured on admission, on biopsy (2-4 weeks after admission) and on discharge from hospital (3 months after admission) using RIA-gnost PIIIP coated tube, an assay kit recently launched by Hoechst Japan Limited. Serum PIIIP on admission showed a good correlation with the degree of hepatic fibrosis and was significantly higher in any disease group than in healthy controls, suggesting its usefulness as an indicator of hepatic fibrosis. After abstinence, however, serum PIIIP level exhibited an increasing tendency in all the disease groups expect alcoholic hepatitis, and the number of laboratory tests showing a significant correlation with PIIIP decreased as compared with that on admission. The mechanism of serum PIIIP elevations seen after abstience is yet to be elucidated in detail, considering their possible association with factors other than collagen synthesis in the liver. (author)

  11. Clinical Significance of Detection of Serum TBA and ALP in Diagnosis of Intrahepatic Cholestasis of Pregnancy

    International Nuclear Information System (INIS)

    Xiong Chuanzheng; Zhu Haibo; Deng jianping

    2009-01-01

    To investigate the clinical value of serum total bile acid (TBA) and alkaline phosphatase (ALP) in diagnosis of intahrpatic cholestasis of pregnancy (ICP), the serum levels of TBA, ALP and cholyglycine (CG) in 47 cases with intahrpatic cholestasis of pregnancy and 60 normal pregnant women were tested by biochemistry analysis and radioimmunoassay. The results showed that the serum levels of TBA and ALP in patients with intahrpatic cholestasis of pregnancy were significantly higher than that of normal pregnancy women. There was a positively correlation between TBA and ALP with CG. The combined determination of serum TBA and ALP could be useful in the diagnosis of intahrpatic cholestasis of pregnancy. Automatic biochemistry analysis of TBA and ALP is more simple and rapid than CG detected by radioimmunoassay,and it is suitable for clinical laboratory application. (authors)

  12. ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors

    International Nuclear Information System (INIS)

    Wang Yiqing; Shi Zhixu

    2002-01-01

    Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors

  13. Ultrasensitive radioimmunoassay for direct determination of free triiodothyronine concentration in serum

    International Nuclear Information System (INIS)

    Weeke, J.; Oerskov, H.

    1975-01-01

    Free triiodothyronine (T 3 ) in serum has been measured directly in dialysates of serum, using a wick chromatographic radioimmunoassay. Adequate sensitivity was attained by the use of [ 125 I]T 3 with a very high specific activity (2,000 to 3,000μCi/μg). Sera were dialysed against a Krebs-Ringer bicarbonate buffer modified so as to be similar to plasma water. Dialysis took place under carefully controlled circumstances. The influence on the equilibrium of total to free T 3 of temperature, serum dilution and dialysis time was studied. By the present method, free T 3 in serum from groups of subjects including 20 men, 10 women taking oral contraceptives and 20 women with normal menstrual cycles were identical, averaging 5.2 pg/ml. A chromatographic radioimmunoassay of total T 3 using high specific activity [ 125 I]T 3 and a very small test sample is also described. (auth.)

  14. Radioimmunological determination of cortisol in serum or plasma of cattle, swine, and sheep

    International Nuclear Information System (INIS)

    Kratzsch, J.; Bier, H.; Leistner, E.; Hubald, J.; Forschungsinst. fuer Koerperkultur und Sport, Leipzig

    1987-01-01

    A radioimmunoassay (RIA) for the determination of the glucocorticoid cortisol in serum or plasma of swine, cattle, and sheep was tested for its clinical validity. Specific antisera were obtained from rabbit, following immunization, using the immunogenic cortisol-3-0-(carboxymethyl)oxime bovine serum albumin. The sensitivity of the method is 6 pg per measured sample or 1.7 nmol/l serum. Cross reactivities of physiologically relevant hormones were below two per cent but for 11-deoxycortisol (9.1 per cent). The resulting high specificity of the RIA proved to enable high accuracy determination of cortisol under conditions of corticosterone or progesterone levels of about 100 per cent with regard to cortisol concentration, that is conditions likely to occur primarily during pregnancy of swine, cattle, and sheep. The cortisol concentrations recorded from serum or plasma of the above species provided a general picture of hormone concentrations and their dimensions which have to be expected under various physiological conditions. (author)

  15. Elevation of serum CA 125 and D-dimer levels associated with rupture of ovarian endometrioma.

    Science.gov (United States)

    Uharcek, P; Mlyncek, M; Ravinger, J

    2007-01-01

    Patients with endometriosis rarely have a serum CA 125 concentration >100 IU/mL. A raised plasma level of D-dimer indicates active fibrinolysis, either secondary to clot formation or primarily activated. This condition is seldom diagnosed in patients with endometriosis. A 53-year-old woman was referred to our institution for acute abdominal pain. Laparoscopic surgery revealed a large ovarian cyst with rupture on the left side. Preoperative laboratory tests detected high serum CA 125 and D-dimer levels. Adnexectomy was performed, resulting in a sharp decrease in serum CA 125 and D-dimer concentration. We describe the clinical course of the patient. Rupture of a large ovarian endometrioma can lead to a high serum concentration of CA 125, a condition which, in addition to the detected pelvic mass, may mimic a malignant process. The increased D-dimer plasma level indicated that a ruptured endometriotic cyst can induce coagulation reactions.

  16. Optimizing cationic and neutral lipids for efficient gene delivery at high serum content.

    Science.gov (United States)

    Chan, Chia-Ling; Ewert, Kai K; Majzoub, Ramsey N; Hwu, Yeu-Kuang; Liang, Keng S; Leal, Cecília; Safinya, Cyrus R

    2014-01-01

    Cationic liposome (CL)-DNA complexes are promising gene delivery vectors with potential application in gene therapy. A key challenge in creating CL-DNA complexes for application is that their transfection efficiency (TE) is adversely affected by serum. In particular, little is known about the effects of a high serum content on TE, even though this may provide design guidelines for application in vivo. We prepared CL-DNA complexes in which we varied the neutral lipid [1,2-dioleoyl-sn-glycerophosphatidylcholine, glycerol-monooleate (GMO), cholesterol], the headgroup charge and chemical structure of the cationic lipid, and the ratio of neutral to cationic lipid; we then measured the TE of these complexes as a function of serum content and assessed their cytotoxicity. We tested selected formulations in two human cancer cell lines (M21/melanoma and PC-3/prostate cancer). In the absence of serum, all CL-DNA complexes of custom-synthesized multivalent lipids show high TE. Certain combinations of multivalent lipids and neutral lipids, such as MVL5(5+)/GMO-DNA complexes or complexes based on the dendritic-headgroup lipid TMVLG3(8+) exhibited high TE both in the absence and presence of serum. Although their TE still dropped to a small extent in the presence of serum, it reached or surpassed that of benchmark commercial transfection reagents, particularly at a high serum content. Two-component vectors (one multivalent cationic lipid and one neutral lipid) can rival or surpass benchmark reagents at low and high serum contents (up to 50%, v/v). We propose guidelines for optimizing the serum resistance of CL-DNA complexes based on a given cationic lipid. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Detection of Hepatitis B Virus (HBV) in Blood Serum By Means of PCR (Polymerase Chain Reaction) Technique

    International Nuclear Information System (INIS)

    Lina, M.; Dadang, S.; Suhadi, F.

    2002-01-01

    Research for detecting the presence of HBV DNA in serum with PCR technique by using two pairs of oligonucleotide primers, has been carried out. Ten serum consisted of 5 HBsAg positive serum, I HBsAg weak positive serum, 3 HBsAg negative serum, and I sampel with negative HBV DNA as a previous PCR product trom another laboratory, were used to purify and to extract the DNA of virus, the sample pretreatment was done with Boom method. The two pairs of primers used for the- PCR process, were PC1 and PC2 and P1 and P2. The amplification process by means of PC1 and PC2 primer was carried out with two treatments, l.a. and l.b treatments of 5 HBsAg positive serum samples, 3 were positive for HBV DNA by PCR test with l.a. treatment. The PCR test by means of either the same primer but different treaunent (l.b treatment) or different pair of primer (pI and P2 pimer), revealed the presence of HBV DNA in all of HBsAg serum mentioned above of HBsAg negative Seruln, I serum was positive for HBV DNA and it was an amplification product of PCR test by using PI and P2 primer. The amplification products of PCR processwith either l.b treatment or PI and P2 primer, showed the positive results for I HBV positive serum as a previous PCR product trom another laboratory. All of the PCR test in this research provided the negative HBV DNA result in the HBsAg weak positive serum. The DNA amplification process by means of PI and P2 primer was more sensitive compared with PC I and PC2 primer

  18. Serum prognostic biomarkers in head and neck cancer patients.

    Science.gov (United States)

    Lin, Ho-Sheng; Siddiq, Fauzia; Talwar, Harvinder S; Chen, Wei; Voichita, Calin; Draghici, Sorin; Jeyapalan, Gerald; Chatterjee, Madhumita; Fribley, Andrew; Yoo, George H; Sethi, Seema; Kim, Harold; Sukari, Ammar; Folbe, Adam J; Tainsky, Michael A

    2014-08-01

    A reliable estimate of survival is important as it may impact treatment choice. The objective of this study is to identify serum autoantibody biomarkers that can be used to improve prognostication for patients affected with head and neck squamous cell carcinoma (HNSCC). Prospective cohort study. A panel of 130 serum biomarkers, previously selected for cancer detection using microarray-based serological profiling and specialized bioinformatics, were evaluated for their potential as prognostic biomarkers in a cohort of 119 HNSCC patients followed for up to 12.7 years. A biomarker was considered positive if its reactivity to the particular patient's serum was greater than one standard deviation above the mean reactivity to sera from the other 118 patients, using a leave-one-out cross-validation model. Survival curves were estimated according to the Kaplan-Meier method, and statistically significant differences in survival were examined using the log rank test. Independent prognostic biomarkers were identified following analysis using multivariate Cox proportional hazards models. Poor overall survival was associated with African Americans (hazard ratio [HR] for death = 2.61; 95% confidence interval [CI]: 1.58-4.33; P = .000), advanced stage (HR = 2.79; 95% CI: 1.40-5.57; P = .004), and recurrent disease (HR = 6.66; 95% CI: 2.54-17.44; P = .000). On multivariable Cox analysis adjusted for covariates (race and stage), six of the 130 markers evaluated were found to be independent prognosticators of overall survival. The results shown here are promising and demonstrate the potential use of serum biomarkers for prognostication in HNSCC patients. Further clinical trials to include larger samples of patients across multiple centers may be warranted. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Decreased serum homocysteine levels after micronutrient supplementation in older people

    Directory of Open Access Journals (Sweden)

    Pusparini Pusparini

    2016-02-01

    Full Text Available Aging is associated with a gradual impairment in cognitive function. The elderly also show a high prevalence of undernutrition, whereas nutrition plays an important role in the metabolism of neuronal cells and enzymes. Homocysteine is an amino acid resulting from methionine metabolism and is dependent on intake of vitamin B12, vitamin B6 and folic acid. Homocysteine is said to play a role in cognitive function. The objective of this study was to evaluate the effect of micronutrient supplementation for 6 months on serum homocysteine levels and cognitive function in older people. This study was an experimental study of pre-post test design, carried out in Mampang subdistrict, South Jakarta. A total of 94 elderly people was recruited for this study, consisting of 44 females and 50 males. Serum homocysteine level was assessed by fluorescent polarization immunoassay and cognitive function by means of the mini mental state examination (MMSE before and after micronutrient supplementation. Mean serum homocysteine concentration after supplementation decreased significantly to 14.8 ± 5.8 mmol/L, compared with mean serum homocysteine level of 15.9 ± 5.9 mmol/L before supplementation (p=0.000. Multiple regression analysis indicated that the factors influencing post-supplementation MMSE scores were gender (â=-0.350; p=0.000, education (â=0.510; p=0.000 and post-supplementation homocysteine levels (â=-0.201; p=0.000, while age, pre-supplementation homocysteine levels and BMI did not affect MMSE scores. Homocysteine concentration decreased significantly after 6 months of supplementation. The factors affecting post-supplementation MMSE scores were gender, level of education, and post-supplementation homocysteine level.

  20. Decreased serum homocysteine levels after micronutrient supplementation in older people

    Directory of Open Access Journals (Sweden)

    Pusparini

    2010-12-01

    Full Text Available Aging is associated with a gradual impairment in cognitive function. The elderly also show a high prevalence of undernutrition, whereas nutrition plays an important role in the metabolism of neuronal cells and enzymes. Homocysteine is an amino acid resulting from methionine metabolism and is dependent on intake of vitamin B12, vitamin B6 and folic acid. Homocysteine is said to play a role in cognitive function. The objective of this study was to evaluate the effect of micronutrient supplementation for 6 months on serum homocysteine levels and cognitive function in older people. This study was an experimental study of pre-post test design, carried out in Mampang subdistrict, South Jakarta. A total of 94 elderly people was recruited for this study, consisting of 44 females and 50 males. Serum homocysteine level was assessed by fluorescent polarization immunoassay and cognitive function by means of the mini mental state examination (MMSE before and after micronutrient supplementation. Mean serum homocysteine concentration after supplementation decreased significantly to 14.8 ± 5.8 mmol/L, compared with mean serum homocysteine level of 15.9 ± 5.9 mmol/L before supplementation (p=0.000. Multiple regression analysis indicated that the factors influencing post-supplementation MMSE scores were gender (â=-0.350; p=0.000, education (â=0.510; p=0.000 and post-supplementation homocysteine levels (â=-0.201; p=0.000, while age, pre-supplementation homocysteine levels and BMI did not affect MMSE scores. Homocysteine concentration decreased significantly after 6 months of supplementation. The factors affecting post-supplementation MMSE scores were gender, level of education, and post-supplementation homocysteine level.

  1. Study of serum lipids in leprosy

    Directory of Open Access Journals (Sweden)

    Gupta Anju

    2002-01-01

    Full Text Available Fifty fresh and untreated patients of leprosy constituted the study group. Fifty, age and sex matched healthy individuals formed the controls. Ridly and Jopling system of classification was used in the study. Majority i.e 21 cases were of BT group, 12 of BB, 7 of BL, 9 of LL and one case was of TT leprosy. The serum triglyceride level was lower than normal in TT, showed no alteration in BT or BB and was insignificantly increased in bL and LL patients. The total cholesterol was lowerthan normal in TT, showed no alteration in BT or BB and was insignificantly increased in Bland LL patients. The total cholesterol was lower than normal in TT, whereas in BT, BB, BL and LL groups the levels were statistically decreased. The HDL cholesterol was within normal range in TT, significantly decreased in BT and LL patients, showed no significant alteration in BB and was insignificantly decreased in BL group. The LDL cholesterol in TT was low but was not so low statistically when compared with the controls, whereas in BT, BB, BL and LL groups the levels were statistically decreased. The VLDL cholesterol was within normal range in TT and BT, was raised insignificantly in 3 of 12 cases of BB, was within normal range in BL and in LL leprosy it was raised in one out of 9 cases. In the absence of any derangement of liver function tests, it can be concluded that leprosy per se leads to alterations in lipid metabolism. However, no correlation could be established between the group/type of leprosy, bacterial indices and levels of different lipid fractions in the present study.

  2. Fluorimetric determination of cholesterol in hypercholesterolemia serum

    Science.gov (United States)

    Lan, Xiufeng; Liu, Jiangang; Liu, Ying; Luo, Xiaosen; Lu, Jian; Ni, Xiaowu

    2005-01-01

    With the increase of people"s living standard and the changes of living form, the number of people who suffer from hypercholesterolemia is increasing. It is not only harmful to heart and blood vessel, but also leading to obstruction of cognition. The conventional blood detection technology has weakness such as complex operation, long detecting period, and bad visibility. In order to develop a new detection method that can checkout hypercholesterolemia conveniently, spectroscopy of cholesterol in hypercholesterolemia serum is obtained by the multifunctional grating spectrograph. The experiment results indicate that, under the excitation of light-emitting diode (LED) with the wavelength at 407 nm, the serum from normal human and the hypercholesterolemia serum emit different fluorescence spectra. The former can emit one fluorescence region with the peak locating at 516 nm while the latter can emit two more regions with peaks locating at 560 nm and 588 nm. Moreover, the fluorescence intensity of serum is non-linear increasing with the concentration of cholesterol increases when the concentration of cholesterol is lower than 13.8 mmol/L, and then, with the concentration of cholesterol increase, the fluorescence intensity decreases. However, the fluorescence intensity is still much higher than that of serum from normal human. Conclusions can be educed from the experiments: the intensity and the shape of fluorescence spectra of hypercholesterolemia serum are different of those of normal serum, from which the cholesterol abnormal in blood can be judged. The consequences in this paper may offer an experimental reference for the diagnosis of the hypercholesterolemia.

  3. Serum prolactin level in patients taking olanzapine

    Directory of Open Access Journals (Sweden)

    Diganta Das

    2015-01-01

    Full Text Available Introduction: Olanzapine is a commonly used antipsychotic. Prolactin elevation is a common adverse effect of anstipsychotics, and serum prolactin elevation is seen in about 30% patients treated with olanzapine. There are confounding results about dose dependency of olanzapine and prolactin elevation, and also the duration of treatment. Method: Fifty six patients, 36 male and 20 female, who were taking olanzapine for any condition for more than a month at a constant dose were enrolled in the study. Patients’ age, weight, body mass index (BMI, serum prolactin levels, and some biochemical values were recorded. Patients were taken from the review outpatient department (OPD after due consent. Results: Five each in male and female groups showed elevation of serum prolactin (estimated to be high if >20 ng/dl for males, and >25 ng/dl for females. In females, the elevation was found at lesser dose of olanzapine (13 mg/day, in males 18 mg/day and early in the treatment (2.4 months vs. 9.7 months in males. Males tended to show raised prolactin with higher doses of olanzapine (mean 18 mg/day. Females (26.31% also showed higher prevalence of prolactin elevation compared to males (13.51%. No other parameter was found to modify the prolactin levels. Conclusion: Olanzapine causes elevation of serum prolactin, though lesser degree than some other antipsychotics. Females are more prone to have raised serum prolactin with olanzapine compared to males. However, the elevation seems to be transient. Higher doses of olanzapine tend to cause elevation of serum prolactin. Serum prolactin estimation in patients taking olanzapine may be undertaken to maintain quality life, particularly in females.

  4. The Role of Serum Uric Acid in Preeclampsia

    Directory of Open Access Journals (Sweden)

    Amir Taefi

    2008-09-01

    Full Text Available Objective: The goal of this study was to assess the utility of serum uric acid in preeclampsia diagnosis and its correlation with some maternal and fetal outcomes.Materials and methods: A case-control study was performed on 26 term pregnant women with preeclampsia and 52 normal pregnant women. Serum uric acid, platelet count, hematocrit, gestational age, and birth weight of all patients were measured. Data distribution was assessed with the one sample Kolmogorov-Smirnov test. Mann-Whitney U test was used to assess differences between groups. Correlations between plasma uric acid and other parameters were evaluated with the Spearman’s Rho or Pearson correlation test, where appropriated. Receiver-operating characteristics (ROC curves were used to assess the ability of plasma uric acid to distinguish the preeclampsia from normal subjects. Significance was set at P< 0.05.Results: The mean level of plasma uric acid was 5.8 (+2 mg/dl in cases and 4.9 mg/dl in controls (P=0.04. ROC curve analysis demonstrates the absence of obvious cut off point for plasma uric acid to distinguish preeclampsia. Sensitivity and specificity for uric acid level of 5.5 mg/dl were 61.5% and 78.8%, respectively. There was no significant linear correlation between the plasma uric acid level and other measured parameters in each group.Conclusion: On the basis of our data, the clinical utility of measuring serum uric acid levels in diagnosing preeclampsia is limited.

  5. Clinical Usefulness of Serum Cystatin C as a Marker of Renal Function

    Directory of Open Access Journals (Sweden)

    Kwang-Sook Woo

    2014-08-01

    Full Text Available BackgroundAccurate renal function measurements are important in the diagnosis and treatment of kidney diseases. In contrast to creatinine, the production of serum cystatin C has been extensively reported to be unaffected by body muscle mass, age, gender, and nutritional status.MethodsOur study included 37 samples from diabetic chronic kidney disease (CKD patients for whom serum creatinine tests had been requested and 40 samples from a healthy populations in Dong-A University Hospital between May 2010 and June 2010. The assay precision (i.e., the coefficient of variation and the reference range of the serum cystatin C test were evaluated. We compared the estimated glomerular filtration rates (GFRs based on cystatin C with those based on creatinine. Moreover, we investigated the influences of age, gender, weight, and muscle mass on serum creatinine and serum cystatin C.ResultsThere was a positive correlation between GFR based on creatinine and that based on cystatin C (r=0.79, P<0.0001 among the diabetic CKD patients. Serum creatinine and cystatin C were significantly correlated with body weight and muscle mass, but the strengths of these correlations were greater for serum creatinine. The precision study revealed excellent results for both the high and low controls. The 95% reference interval of cystatin C in the healthy population was 0.371 to 1.236 mg/L.ConclusionBased on these results, we conclude that, despite the strong correlation between serum creatinine and cystatin C, cystatin C is less affected by weight and muscle mass and might represent a better alternative for the assessment of renal function.

  6. Pancreatic exocrine function testing

    International Nuclear Information System (INIS)

    Goff, J.S.

    1981-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and para-aminobenzoic acid bound to a dipeptide. Of all these tests the secretin stimulation test is the most accurate and reliable if done by experienced personnel. However, the indirect tests are simpler to do and appear to be comparable to the secretin test at detecting pancreatic exocrine insufficiency. These indirect tests are becoming clinically available and clinicians should familiarize themselves with the strengths and weaknesses of each

  7. Serum and Urine Copper – Contamination and Stability

    OpenAIRE

    Dimitrova Ivanova I.; Atanasova B.; Dragneva S.; Vladimirova L.; Krastev Z.; Kostadinova A.; Ivanova A.; Tzatchev K.

    2015-01-01

    Pre-analytical factors of variation need to be carefully considered and investigated in efforts to harmonize all aspects of the total testing process. This study aimed to evaluate contamination and stability in copper (Cu) analysis of serum and urine by flame atomic absorption spectroscopy (FAAS) and to compare the stability of urine Cu in controls and in D-penicillamine (D-PA) administration. Cu was measured by AAnalyst 400, Perkin Elmer, USA. Blood was collected in BD Vacutainer®SSTTM II Ad...

  8. Serum immunoreactive calcitonin concentration in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Dugard, J; Kew, M C; Da Fonseca, M; Levin, J [University of the Witwatersrand, Johannesburg (South Africa)

    1982-08-21

    Having found raised serum calcitonin concentrations in 94% of patients with hepatocellular carcinoma when using a dextran-coated-charcoal radio-immunoassay, we have now repeated the study, using a double-antibody radio-immunoassay, in 102 further patients with hepatocellular carcinoma and 35 matched controls. Serum immunoreactive calcitonin concentrations (iCT) in the controls ranged from 10 to 310 pg/ml (mean 154,6 pg/ml). Values in the tumour patients ranged from 10 to 1,650 pg/ml (mean 302,6 pg/ml). The mean figures were significantly higher in the tumour patients (P smaller than 0,001), 35.5% of them having values above 310 pg/ml. In 65 of the patients serum iCT concentrations were also determined by dextran-coated-charcoal radio-immunoassay. Values ranged from 10 to 10780 pg/ml (mean 2,179 pg/ml). If 1,000 pg/ml is taken as the upper limit of normal, 69% of the patients had raised iCT concentrations. There was a good correlation (r=0,67; P smaller than 0,001) between serum iCT values measured with both methods in 50 patients. If measured by the double-antibody radio-immunoassay method, the serum calcitonin value is not useful as a marker for hepatocellular carcinoma.

  9. Serum immunoreactive calcitonin concentration in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Dugard, J.; Kew, M.C.; Da Fonseca, M.; Levin, J.

    1982-01-01

    Having found raised serum calcitonin concentrations is 94% of patients with hepatocellular carcinoma when using a dextran-coated-charcoal radio-immunoassay, we have now repeated the study, using a double-antibody radio-immunoassay, in 102 further patients with hepatocellular carcinoma and 35 matched controls. Serum immunoreactive calcitonin concentrations (iCT) in the controls ranged from 10 to 310 pg/ml (mean 154,6 pg/ml). Values in the tumour patients ranged from 10 to 1 650 pg/ml (mean 302,6 pg/ml). The mean figures were significantly higher in the tumour patients (P smaller than 0,001), 35,5% of them having values above 310 pg/ml. In 65 of the patients serum iCT concentrations were also determined by dextran-coated-charcoal radio-immunoassay. Values ranged from 10 to 10780 pg/ml (mean 2 179 pg/ml). If 1 000 pg/ml is taken as the upper limit of normal, 69% of the patients had raised iCT concentrations. There was a good correlation (r=0,67; P smaller than 0,001) between serum iCT values measured with both methods in 50 patients. If measured by the double-antibody radio-immunoassay method, the serum calcitonin value is not useful as a marker for hepatocellular carcinoma

  10. Maternal serum levels of adiponectin in preeclampsia

    International Nuclear Information System (INIS)

    Khosrowbeygi, A.; Ahmadvand, H.

    2009-01-01

    The results of the serum levels of adiponectin in pre eclamptic patients are conflicting. Objective: The aim of the present study was to assess serum levels of adiponectin in women with pre eclampsia compared with healthy pregnant women. Methods: A cross-sectional study was designed. The case group consisted of women with pre eclampsia (n=30). The control group consisted of 30 matched normal pregnant women. Serum levels of adiponectin were assessed using enzyme-linked immunosorbent assay method. Results: Serum levels of adiponectin were significantly higher in the pre eclamptic group than those in the normal control group. In the pre eclamptic patients serum levels of adiponectin showed a significant negative correlation with body mass index while no correlation was found in the normal pregnant women. In women with pre eclampsia, levels of adiponectin were decreased significantly in the overweight women compared with normal weight women, while in the control group no significant difference was observed. Conclusion: In conclusion, elevation of adiponectin levels might be a physiological feedback response to minimize endothelial dysfunction in pre eclamptic patients. (author)

  11. Immunoradiometric assay for ferritin in human serum

    International Nuclear Information System (INIS)

    Leyland, M.J.; Ganguli, P.C.; Blower, D.; Delamore, I.W.

    1975-01-01

    A sensitiv specific and precise immunoradiometric assay for ferritin has been developed. Ferritin was measured in the serum of 160 hospital controls, 101 females (118 plus/minus 9 μg/l) and 59 males (189 plus/minus 16 μg/l). This difference was statistically significant. In 28 patients with untreated iron deficiency anemia, serum ferritin concentration (6.1plus/minus 0.7 μg/l) was significantly lower than in the controls, but it was within the normal range in 14 cases of polycythaemia vera treated by repeated phlebotomy. In 4 patients with primary haemachromatosis (2884 plus/minus 56 μg/l), 25 with secondary iron overload states (5702 plus/minus 1235 μg/l) and 8 with haemolytic anaemia (1612 plus/minus 605 μg/l), serum ferritin levels were markedly elevated. In 14 cases of transfusional siderosis there was a highly significant correlation between serum ferritin concentration and units of blood transfused. A circadian rhythmin serum ferritin concentration was observed in 7 healthy subjects. (author)

  12. Serum zinc level in children with malnutrition

    International Nuclear Information System (INIS)

    Ahmad, T.M.; Mahmood, M.T.; Baluch, G.R.; Bhatti, M.T.

    2000-01-01

    Serum zinc level amongst children with protein energy malnutrition (PEM) was evaluated in a control study conducted in the Department of Paediatrics, Allama Iqbal Medical College and Jinnah Hospital, Lahore. Twenty-five children with PEM and 25 healthy children as control from the community were screened. Mean serum zinc level was found to be 54.48 -+ 18.91 mg/dl in children with PEM while it was 72.72 -+ 8.21 mg/dl in control group (P < 0.001). No significant difference in zinc level was noted between both sexes in each group. Marasmic 16 children revealed mean serum zinc level of 57.55 -+ 18.16 mg/dl while in Kwashiorkor it was 44.57 -+ 13.66 mg/dl. Serum zinc was significantly low in Kwashiorkor than in marasmus (P < 0.001). It was also significantly low in children with acute or chronic diarrhea associated with malnutrition (44.66 -+ 16.0 mg/dl). Acute respiratory infections in these children were not associated with low serum zinc level (71.66 -+ 16.51 mg/dl). (author)

  13. Serum iron parameters in liver cirrhosis

    Science.gov (United States)

    Siregar, G. A.; Maail, W.

    2018-03-01

    The liver plays a fundamental role in iron homeostasis. Iron parameters change, especially ferritin, need to be evaluated in patients with liver cirrhosis. Serum ferritin could predict the prognosis of patients with decompensated cirrhosis since it reflects immunemediated and infectious stimuli. Ferritin could express the severity of liver disease and possible subsequent complications. Finally, it might reflect an iron overload condition resulting in significant morbidity and early mortality. 70 patients with decompensated liver cirrhosis divided into three Child-Pugh subgroups. Serum iron parameters include serum iron (SI), total iron binding capacity (TIBC) and ferritin was measured in these groups. From these 70 patients, 30 (42.9%) with HbsAg positive, 26 (37.1%) with anti-HCV positive and 14 (20%) with both HbsAg and anti-HCV positive. Of the 70 patients, 14 (20%) had CTP Class A cirrhosis, 17 (24.3%) had CTP Class B cirrhosis, and 39 (55.7%) had CTP C cirrhosis. The median (range) value of serum iron was 36 (10-345) μg/dl, TIBC was 160 (59-520) μg/dl, Ferritin was 253.5 (8-6078) ng/ml and the transferrin saturation was 22.9 (3.65-216.98) %.We found a significant difference in serum ferritin level with CTP score. Ferritin levels increased as Child-Pugh class progressed (p<0.001).

  14. Elemental analysis of human serum and serum protein fractions by thermal neutron activation

    International Nuclear Information System (INIS)

    Woittiez, J.R.W.

    1984-01-01

    Some applications of thermal neutron activation for the determination of elemental contents in human serum and human serum protein fractions are presented. Firstly total serum is dealt with, secondly serum protein fractions obtained by gel filtration are described. A brief review on the role of (trace) elements in human health and disease and a compilation of literature data for elemental contents in human serum, as obtained by neutron activation techniques, are given. The most important sources of statistical and systematic errors are evaluated. Results for the contents of sodium, potassium, magnesium, bromine, iron, copper, zinc, selenium, rubidium, cesium and antimony in serum are given, with emphasis on control of accuracy and precision. The possible relation between selenium in blood and cancer occurrence in humans is discussed. The results of elemental analyses from cancer patients and from a patient receiving a cytostatic treatment are presented. A survey of literature results for the determination of protein-bound elemental contents in serum is presented. Subsequently, results from a study on the behaviour of elements during gel filtration are discussed. Gel-element and protein-element interactions are studied. Finally the protein-bound occurrence of trace elements in human serum is determined by gel filtration and neutron activation analysis. Results for both desalting and fractionation are given, for the elements bromine, copper, manganese, vanadium, selenium, zinc, rubidium, iron and iodine. (Auth.)

  15. ALPHA-FETOPROTEIN IN FETAL SERUM, AMNIOTIC-FLUID, AND MATERNAL SERUM

    NARCIS (Netherlands)

    VANLITH, JMM; BEEKHUIS, [No Value; VANLOON, AJ; MANTINGH, A; DEWOLF, BTHM; BREED, ASPM

    In order to gain more insight into the association between alpha-fetoprotein (AFP) and fetal chromosomal disorders, especially Down's syndrome, we measured AFP in fetal serum, amniotic fluid, and maternal serum at cordocentesis. We compared the concentration and gradient of AFP in these three

  16. Serum proteinase inhibitors and other serum proteins in protein-energy malnutrition

    NARCIS (Netherlands)

    Schelp, F.P.; Migasena, P.; Pongpaew, P.; SCHREURS W.H.P

    1977-01-01

    1. The concentrations of serum protein albumin, prealbumin and transferrin were determined in twenty-eight cases of protein-energy malnutrition (PEM) with infection, together with the levels of serum proteinase inhibitors (PI), alpha1-antitrypsin (AT), alpha1-antichymotrypsin (Ach),

  17. Association between serum interleukin-6 and serum 3,5,3'-triiodothyronine in nonthyroidal illness

    NARCIS (Netherlands)

    Boelen, A.; Platvoet-ter Schiphorst, M. C.; Wiersinga, W. M.

    1993-01-01

    Increased serum concentrations of FFA, bilirubin, and carboxyl-methyl-propyl-furanpropionic acid, accumulating in chronic renal failure in direct relationship with serum creatinine, have all been implicated in the pathogenesis of the low T3 syndrome during illness. Cytokines may also be involved in

  18. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  19. Zinc in human serum. Biochemical and clinical aspects. Zink i humant serum. Biokemiske og kliniske aspekter

    Energy Technology Data Exchange (ETDEWEB)

    Kiilerich, S

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 percent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of protein binding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and ..cap alpha../sub 2/-macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a ..cap alpha../sup 2/-macroglobulin in normal persons is appoximately 7 percent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 percent, in patients with insulin dependent diabetes mellitus approximately 5 percent, and in patients with chronic renal failure approximately 2 percent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin.

  20. HIV and other predictors of serum folate, serum ferritin, and hemoglobin in pregnancy

    DEFF Research Database (Denmark)

    Friis, Henrik; Gomo, E; Kæstel, Pernille

    2001-01-01

    BACKGROUND: Folate and iron status and hemoglobin concentrations are important to maternal and infant health. OBJECTIVE: Our goal was to identify predictors of serum folate, serum ferritin, and hemoglobin. DESIGN: This was a cross-sectional study of 1669 pregnant women (22-35 wk of gestation) in ...

  1. Serum cardiac troponin I in acute stroke is related to serum cortisol and TNF-alpha

    DEFF Research Database (Denmark)

    Christensen, Hanne Krarup; Johannesen, Helle Hjorth; Christensen, Anders Fogh

    2004-01-01

    Serum cardiac troponin I (cTnI) is a specific marker of myocardial injury related to in-patient fatality and cardiac injury in acute stroke. We investigated whether cTnI in acute stroke is related to serum cortisol, acute inflammatory response, and insular damage. We also investigated whether c...

  2. A Unique test for Hubble's new Solar Arrays

    Science.gov (United States)

    2000-10-01

    pairs. The arrays use high efficiency solar cells and an advanced structural system to support the solar panels. Unlike the earlier sets, which roll up like window shades, the new arrays are rigid. ESA provided Hubble's first two sets of solar arrays, and built and tested the motors and electronics of the new set provided by NASA Goddard Space Flight Center. Now, this NASA/ESA test has benefits that extend beyond Hubble to the world-wide aerospace community. It will greatly expand basic knowledge of the jitter phenomenon. Engineers across the globe can apply these findings to other spacecraft that are subjected to regular, dramatic changes in sunlight and temperature. Note to editors The Hubble Project The Hubble Space Telescope is a project of international co-operation between the National Aeronautics and Space Administration (NASA) and the European Space Agency (ESA). The partnership agreement between ESA and NASA was signed on 7 October 1977. ESA has provided two pairs of solar panels and one of Hubble's scientific instruments (the Faint Object Camera), as well as a number of other components and supports NASA during routine Servicing Missions to the telescope. In addition, 15 European scientists are working at the Space Telescope Science Institute in Baltimore (STScI), which is responsible for the scientific operation of the Hubble Observatory and is managed by the Association of Universities for Research in Astronomy (AURA) for NASA. In return, European astronomers have guaranteed access to 15% of Hubble's observing time. The Space Telescope European Coordinating Facility (ST-ECF) hosted at the European Southern Observatory (ESO) in Garching bei München, Germany, supports European Hubble users. ESA and ESO jointly operate the ST-ECF.

  3. Determination of triiodothyronine in serum by enzyme- and radioimmunoassay

    International Nuclear Information System (INIS)

    Oellerich, M.; Haindl, H.; Medizinische Hochschule Hannover

    1981-01-01

    An evaluation of a heterogeneous enzyme immunoassay for determination of triiodothyronine in serum (Enzymun-Test T 3 , Boehringer Mannheim) is presented. The enzyme immunoassay was compared with the laboratory routine radioimmunoassay. The precision of both assays was satisfactory at triiodothyronine concentrations between 1.0 and 8.0 nmol/l (coefficients of variation from day to day 3 from 96-104% and with the radioimmunoassay from 88-111%. A comparison of the results obtained by Enzymun-Test T 3 and the radioimmunoassay in a series of 103 patients showed a good correlation between both methods. L-thyroxine did not cause a relevant cross-reaction in the enzyme immunoassay. About 20 unknown samples can be analyzed in triplicate by Enzymun-Test T 3 within 260 minutes. (orig.) [de

  4. Salivary Cortisol Can Replace Free Serum Cortisol Measurements in Patients With Septic Shock

    Science.gov (United States)

    Orlander, Philip R.

    2011-01-01

    Background: There is a renewed interest in adrenal function during severe sepsis. Most studies have used total serum cortisol levels; however, only free serum cortisol is biologically active. The aim of this study was to determine the validity of salivary cortisol levels as a surrogate for free serum cortisol levels during septic shock. Methods: Fifty-seven patients with septic shock were studied to determine the correlation between total serum cortisol and salivary cortisol to free serum cortisol levels. Thirty-eight patients were included in the salivary to free serum cortisol correlation. Salivary cortisol level was tested by enzyme immunoassay. Serum total cortisol, free cortisol, and cortisol-binding globulin (CBG) levels were determined by liquid chromatography-mass spectrometry, equilibrium analysis, and radioimmunoassay, respectively. Results: The mean ± SD age was 56.6 ± 18.5 years. Fifty-seven percent were women. APACHE (Acute Physiology and Chronic Health Evaluation) II score median was 26, Simplified Acute Physiology Score II median was 61, and Sequential Organ Failure Assessment median was 13. The correlation between salivary and free serum cortisol levels was 0.79 (95% CI, 0.63-0.89; P cortisol and total serum cortisol levels was 0.86 (95% CI, 0.78-0.92; P cortisol level was 2.27 ± 1.64 μg/dL. The mean ± SD salivary cortisol level was 2.60 ± 2.69 μg/dL. The mean ± SD total serum cortisol level was 21.56 ± 8.71 μg/dL. The mean ± SD CBG level was 23.54 ± 8.33 mg/dL. Conclusions: Salivary cortisol level can be used as a surrogate of free serum cortisol level in patients with septic shock with very good correlation. Salivary cortisol testing is noninvasive, easy to perform, and can be conducted daily. Trial registry: ClinicalTrials.gov; No.: NCT00523198; URL: www.clinicaltrials.gov PMID:21816912

  5. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  6. Quality of dry chemistry testing.

    Science.gov (United States)

    Nakamura, H; Tatsumi, N

    1999-01-01

    Since the development of the qualitative test paper for urine in 1950s, several kinds of dry-state-reagents and their automated analyzers have been developed. "Dry chemistry" has become to be called since the report on the development of quantitative test paper for serum bilirubin with reflectometer in the end of 1960s and dry chemistry has been world widely known since the presentation on the development of multilayer film reagent for serum biochemical analytes by Eastman Kodak Co at the 10th IFCC Meeting in the end of 1970s. We have reported test menu, results in external quality assessment, merits and demerits, and the future possibilities of dry chemistry.

  7. Radioimmunoassay of progesterone in unextracted serum

    International Nuclear Information System (INIS)

    Haynes, S.P.; Corcoran, J.M.; Eastman, C.J.; Doy, F.A.

    1980-01-01

    A rapid, precise radioimmunoassay for progesterone in 25 μL of unextracted serum is described. Progesterone is released from its binding protein by adding an optimal amount of cortisol, which binds to the same protein (cortisol binding globulin) as progesterone. The amount of cortisol required does not cross react with the specific progesterone antibody used. This approach considerably shortens assay time and removes a tedious and imprecise stage in the conventional assay of serum progesterone. Results correlated well (r = 0.97) with a method involving organic solvent extraction of progesterone from serum. During the two years we have used this mehod in a busy diagnostic endocrine laboratory, the between-assay precision (CV) for low-, medium-, and high-concentration quality control sera was 12, 7, and 9%, respectively. Data from participation in an independent external quality-control program verified the adequacies of the method

  8. Serum Markers of Apoptosis in Traumatic and Ischemic Brain Injury

    Directory of Open Access Journals (Sweden)

    N. N. Yepifantseva

    2009-01-01

    Full Text Available Objective: to study the time course of changes and relationship of the serum indicators of apoptotic processes in neurore-suscitation patients. Subjects and methods. Thirty-eight neuroresuscitation patients, including 14 patients with severe brain injury (SBI (mean age 41.4±4.3 years and 24 patients with strokes (mean age 53.8±2.5 years, were examined. The group of patients with strokes was divided into 2 subroups: 1 11 patients with ischemic strokes (IS and 2 13 with hemorrhagic strokes (HS. The Glasgow coma scores for admission consciousness loss were 7.6±0.8 in the SBI group and 9.5±0.7 in the stroke group; mortality was 28.6 and 37.5%, respectively. A control group included 16 subjects (mean age 47.9±3.8 years. The investigators measured the serum levels of FAS antigen and its ligand (sAPO-I/FAS and sFAS-L, cas-pase-1/ICE, sCD40 (Bender MedSystem, Austria and hTRAIL (Biosource, Belgium by solid-phase immunoassay in neuroresuscitation patients on days 1, 7, and 14 of the acute period of diseases. They used statistical methods, such as Wilcoxon-Mann-Whitney U-test, Spearman’s rank correlation test. Results. A reduction in hTRAIL was observed in all the groups. There was a decrease in serum sCD40 in strokes on days 1 to 14 and in SBI on days 7 to 14. An increase in caspase 1/ICE was seen in HS in the first 24 hours, in IS on days 1 to 7, and in SBI on days 1 to 14. The most pronounced rise in caspase-1/ICE was induced by ischemic brain lesion within the first week of disease. A prolonged increase up to 2 weeks was noted in SBI. No rise in serum FAS-L was found in the examinees. The time course of changes in sAPO-I/FAS was different in all the groups. The most marked, moderate, and none reductions were revealed in HS, IS, and SBI, respectively. There was a pronounced serum sAPO-I/FAS increase in SBI within the first 24 hours. Assessment of correlations between the serum indicators of apoptosis revealed that there were differences in the

  9. Serum ferritin in recurrent oral ulceration

    International Nuclear Information System (INIS)

    Challacombe, S.J.; Scully, C.; Keevil, B.; Lehner, T.

    1983-01-01

    A sensitive radio-assay for ferritin was developed and used to examine serum ferritin levels in 105 patients with recurrent oral ulceration (ROU), 41 patients with Behcet's syndrome (BS), 42 with other ulcerative oral lesions, 35 patients with non-ulcerative oral lesions and in 78 controls. Ferritin levels increased with age and were significantly higher in males than females. The mean ferritin concentrations in male patients with ROU, BS or with other oral ulcers were significantly reduced in comparison with controls, and in female patients were significantly reduced in those with major aphthous ulcers. The prevalence of low serum ferritin levels was about 8% in patients with ROU, 15% in BS and 9.5% in patients with other ulcerative oral lesions, compared with less than 3% in patients with non-ulcerative oral disorders and in controls. Most of the iron-deficient patients were female. Serum ferritin levels did not directly correlate with serum iron levels and may be a more accurate indicator of iron deficiency. Furthermore, serum ferritin can distinguish between patients with true iron deficiency and those with secondary sideropenia. It is suggested that in a small number of patients, oral ulceration may be a presenting sign of iron deficiency, and that in a further small proportion of patients, ROU already present will be exacerbated by concurrent iron deficiency. Both groups will show a therapeutic response to correction of the iron deficiency. The results suggest that serum ferritin levels are a useful part of the haematological investigatons in patients with ROU. (author)

  10. The cholesterol-lowering effect of coconut flakes in humans with moderately raised serum cholesterol.

    Science.gov (United States)

    Trinidad, Trinidad P; Loyola, Anacleta S; Mallillin, Aida C; Valdez, Divinagracia H; Askali, Faridah C; Castillo, Joan C; Resaba, Rosario L; Masa, Dina B

    2004-01-01

    This study investigated the effect of coconut flakes on serum cholesterol levels of humans with moderately raised serum cholesterol in 21 subjects. The serum total cholesterol of subjects differed and ranged from 259 to 283 mg/dL. The study was conducted in a double-blind randomized crossover design on a 14-week period, consisting of four 2-week experimental periods, with each experimental period separated by a 2-week washout period. The test foods were as follows: corn flakes as the control food, oat bran flakes as the reference food, and corn flakes with 15% and 25% dietary fiber from coconut flakes (made from coconut flour production). Results showed a significant percent reduction in serum total and low-density lipoprotein (LDL) cholesterol (in mg/dL) for all test foods, except for corn flakes, as follows: oat bran flakes, 8.4 +/- 1.4 and 8.8 +/- 6.0, respectively; 15% coconut flakes, 6.9 +/- 1.1 and 11.0 +/- 4.0, respectively; and 25% coconut flakes, 10.8 +/- 1.3 and 9.2 +/- 5.4, respectively. Serum triglycerides were significantly reduced for all test foods: corn flakes, 14.5 +/- 6.3%; oat bran flakes, 22.7 +/- 2.9%; 15% coconut flakes, 19.3 +/- 5.7%; and 25% coconut flakes, 21.8 +/- 6.0%. Only 60% of the subjects were considered for serum triglycerides reduction (serum triglycerides >170 mg/dL). In conclusion, both 15% and 25% coconut flakes reduced serum total and LDL cholesterol and serum triglycerides of humans with moderately raised serum cholesterol levels. Coconut flour is a good source of both soluble and insoluble dietary fiber, and both types of fiber may have significant role in the reduction of the above lipid biomarker. To our knowledge, this is the first study conducted to show a relationship between dietary fiber from a coconut by-product and a lipid biomarker. Results from this study serves as a good basis in the development of coconut flakes/flour as a functional food, justifying the increased production of coconut and coconut by-products.

  11. Embryogenesis-promoting factors in rat serum.

    Science.gov (United States)

    Katoh, M; Kimura, R; Shoji, R

    1998-06-15

    Regarding whole rat embryo cultures in vitro, rat serum as a culture medium is known to support the normal growth of rat embryos in the organogenesis phase. The purpose of the present study was to isolate the embryogenesis-promoting factors from rat serum as a first step in the development of a defined serum-free medium for a whole embryo culture system. Pooled rat serum after heat inactivation was fractionated into three major peaks (frA, containing a region of void volume, frB, and frC) by gel filtration. The 9.5-day rat embryos that were cultivated for 48 hr in essential salt medium containing frB (with a molecular size range of 100-500 kDa) revealed normal growth. Three proteins (27 kDa, 76 kDa, and 190 kDa) that had the embryogenesis-promoting effects were isolated from 3-hr delayed centrifuged rat serum by the ion exchange chromatography. The 76-kDa protein was found to be rat transferrin by immunoblotting. The 27-kDa protein was identified as apo-AI (the major apoprotein of high-density lipoprotein) by immunoblotting. High-density lipoprotein obtained from pooled rat serum by a NaBr density gradient ultracentrifugation was found to have a positive effect on embryogenesis. The 10-kDa protein was also identified as alpha 1-inhibitor 3 by immunoblotting. In addition, the embryogenesis-promoting effect of the fraction containing 27-kDa and 190-kDa proteins declined within a short period of storage at -20 degrees C. This decrease was countered by supplementing its fraction (D-2) with albumin isolated from rat serum. These results in the present study suggest that transferrin, high-density lipoprotein, and alpha 1-inhibitor 3 in rat serum may be embryogenesis-promoting factors, and that albumin appeared to play a role in the embryogenesis of rat embryos in whole embryo cultures.

  12. Study of Serum Magnesium in Surgical Stress

    Directory of Open Access Journals (Sweden)

    Sandip D. Lambe

    2016-10-01

    Full Text Available Background: A deficiency of magnesium is of clinical importance in hospitalized patients. The prevalence of hypomagnesaemia is high in critically ill patients. Knowing the important role of magnesium in surgical cases, it is necessary to anticipate and diagnose magnesium deficiency prior to surgery and in the immediate postoperative period to correct it. Aims and Objectives: The aim of this study was to analyse serum magnesium levels in patients undergoing emergency surgical procedures, planned surgical procedures and normal healthy matched controls and to compare the serum magnesium levels in all the three groups. Materials and Methods: The study participants were divided into three groups: i Group I: patients undergoing emergency major surgery ii Group II: patients undergoing planned major surgery iii Group III: normal healthy controls. Serum Magnesium investigation was done by Xylidyl Blue Method using UV-1800/Shimadzu UV-Spectrophotometer. Results: The mean serum Magnesium in control group was found to be 2.16 ± 0.30 mg/dl. In patients undergoing planned surgery, pre-operative serum magnesium was normal (2.16 ± 0.22 mg/dl but decreased significantly on postoperative day 3 (1.63 ± 0.27 mg/dl and day 6 (1.97 ± 0.12 mg/dl and returned to normal level by post-operative day 9 (2.14 ± 0.14 mg/dl compared to controls. In patients undergoing emergency surgery, serum magnesium was decreased pre-operatively (1.90 ± 0.48 mg/dl.Further significant reduction was found at post-operative day 3 (1.38 ± 0.28 mg/dl, day 6 (1.59 ± 0.30 mg/dl and day 9 (1.88 ± 0.46 mg/dl compared to controls. Mean serum Magnesium overall in emergency surgery patients was reduced significantly compared to planned surgery patients. Conclusion: A transient fall in the serum Magnesium as compared to its pre-operative level was seen in every patient undergoing surgical procedure due to surgical stress. In patients undergoing emergency surgical procedure, the decrease was

  13. Serum YKL-40 and colorectal cancer

    DEFF Research Database (Denmark)

    Cintin, C; Johansen, J S; Christensen, Ib Jarle

    1999-01-01

    related to short survival. In the present study we analysed YKL-40 in preoperative sera from patients with colorectal cancer and evaluated its relation to survival. Serum YKL-40 was determined by RIA in 603 patients. Survival after operation was registered, and median follow-up time was 61 months. Three......YKL-40 is a mammalian member of the chitinase protein family. Although the function of YKL-40 is unknown, the pattern of its expression suggests a function in remodelling or degradation of extracellular matrix. High serum YKL-40 has been found in patients with recurrent breast cancer and has been...

  14. Competitive radioimmunoassay of digoxin in serum

    International Nuclear Information System (INIS)

    Oslapas, Raymond; Herrin, T.R.

    1975-01-01

    The process described is for determining the digoxin level of a serum. To do so a mixture is made by adding to the serum sample an antidigoxin antibody and a suitable labelling quantity of O 3 -(hydroxy-4 phenethylcarbamoyl)digoxigenin for radioactive labelling. The mixture is allowed to incubate so that the digoxin of the sample and the radioactive labelling reagent joint to the antidigoxin antibody. A precipitating agent is added to the mixture to help the formation of a precipitate and thus separate the labelled digoxin taken up from the precipitate free digoxin. The liquid is separated from the precipitate formed and the residual radioactivity of the precipitate is measured [fr

  15. Radioimmunoassay of serum myoglobin in neuromuscular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Askmark, H; Osterman, P O; Roxin, L E; Venge, P [University Hospital, Uppsala (Sweden)

    1981-01-01

    Radioimmunoassay of serum myoglobin was performed in 85 patients with muscular symptoms. Elevated levels were found in 93% of patients with myogenic myopathy, in 54% with myasthenia gravis and in 50% with neurogenic myopathy. All 11 patients with polymyositis had elevated myoglobin concentrations. In six of seven patients with polymyositis, who were followed up with repeated determinations, a clear relationship between myoglobin levels and clinical course was found. In general serum myoglobin seemed to be a more sensitive indicator of muscle disease than creatine kinase.

  16. Radioimmunoassay of serum myoglobin in neuromuscular diseases

    International Nuclear Information System (INIS)

    Askmark, H.; Osterman, P.O.; Roxin, L.-E.; Venge, P.

    1981-01-01

    Radioimmunoassay of serum myoglobin was performed in 85 patients with muscular symptoms. Elevated levels were found in 93% of patients with myogenic myopathy, in 54% with myasthenia gravis and in 50% with neurogenic myopathy. All 11 patients with polymyositis had elevated myoglobin concentrations. In six of seven patients with polymyositis, who were followed up with repeated determinations, a clear relationship between myoglobin levels and clinical course was found. In general serum myoglobin seemed to be a more sensitive indicator of muscle disease than creatine kinase. (author)

  17. HYPOLIPEMIC THERAPY AND LOW SERUM CHOLESTEROL CONCENTRATION

    Directory of Open Access Journals (Sweden)

    Vladmila Bojanic

    2004-01-01

    Full Text Available Low concentration of plasma lipoproteins (hypolipoproteinemia presents decreasing concentrations of all or particular lipids components. Classification of hypolipoproteinemia (hypoLP divides them into: primary (hereditary and secondary. Primary hipoLP are rare diseases and their main characteristic is disorder of apolipoproteins synthesis, which leads to low serum cholesterol concentration. Secondary hipoLP are presented in many diseases. They have diagnostic, prognostic significance and present good therapeutic marker. However, modern therapeutic approaches for aggressive lipid lowering pointed out many questions about physiological limits for cholesterol lowering. These approaches, also, open many questions about consequences of low serum concentration of total cholesterol and triglicerides.

  18. Analysis of serum angiotensin-converting enzyme.

    Science.gov (United States)

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  19. Serum free light chain reference values: a critical approach.

    Science.gov (United States)

    Altinier, Sara; Seguso, Mara; Zaninotto, Martina; Varagnolo, Mariacristina; Adami, Fausto; Angeli, Paolo; Plebani, Mario

    2013-05-01

    The clinical usefulness of serum free light chain (FLC) measurement in the management of patients with plasma cell proliferative disorders has been reported in several papers, and most clinical studies use the reference ranges declared by the manufacturer. The aim of the present study was to evaluate the reproducibility of FLCs immunoassay and to validate the reference range, before introducing it in routine setting. Internal quality control materials and a pool of fresh serum samples were used to evaluate imprecision; 162 fresh sera from healthy blood donors were analyzed to evaluate the reference range for FLCs. In order to verify the κ/λ FLC ratio, 43 sera from patients with polyclonal hypergammaglobulinemia were tested. The FLC immunoassay was performed using a nephelometer with the Freelite reagents. The imprecision studies performed using a serum pool tested with two different lots of reagents showed a mean CV of 16.09% for κFLC and of 16.72% for λFLC. Lower CV%s and different mean values were found by calculating the results from each specific lot separately, while different results were obtained using the control materials provided by the manufacturer. In reference subjects, the 2.5-97.5th percentiles were found to be 4.52-22.33 and 4.84-21.88mg/L for κFLC and λFLC, respectively. The range for κ/λ ratio (0.65-2.36) was validated with the values obtained from subjects with polyclonal hypergammaglobulinemia. In retesting 15 samples from blood donor subjects with a different lot of reagents, mean bias percentages of 17.60 for κFLC and 15.26 for λFLC were obtained. These findings confirm the lot-to-lot variability of the FLC assays also in the measurement of polyclonal light chains, as well as the need to carefully validate the reference values. Published by Elsevier Inc.

  20. Kromium serum dan asupan mikromineral pada penyandang diabetes tipe 2

    Directory of Open Access Journals (Sweden)

    Ni Ketut Sutiari

    2017-04-01

    Full Text Available Background: Status of minerals such as zinc, magnesium, and chromium among diabetic patients are considered lower than non-diabetic peoples, both in the serum and intake. Some reviews show that those minerals contribute to carbohydrate metabolism among diabetic patients. Objective: This study aims to explore intake of zinc, magnesium, and chromium among DMT2 in Denpasar. Method: This is a cross-sectional analytic study. The population was all (70 DMT2 patients registered at Chronic Disease Service (Prolanis at two Primary Health Care (PHC Denpasar Utara III PHC and Denpasar Timur I PHC. The sample for the study was DMT2 patients and non-diabetic people age 50-70 years reside in Denpasar city. DMT2 patients were randomly selected with simple random technique, while non-diabetic peoples were non-randomly selected. The level of serum chromium was measured by AAS method, whereas microminerals intake were collected by a recall and SQ-FFQ method. Data was analyzed descriptively and differences were tested with two independent t-test at 95% confidence level. Results: The mean of serum chromium DMT2 and non-diabetic were 0.044 mg/L and 0.094 mg/L respectively. The mean±SEM magnesium (DMT2 316.1±22.4 mg/day; non-diabetic 211.0±33.5 mg/day, zinc intake was (DMT2 8.4±0.7 mg/day; non-diabetic 6.2±0.8 mg/day, and chromium (DMT2 10.8±1.3 µg/day; non-diabetic 8.7±0.9µg/day. A significant difference was found between magnesium intake (p=0.01. Conclusion: The study showed that zinc, magnesium and chromium intake is appeared higher among DMT2 patients compare to non-diabetic in Denpasar region.

  1. Serum microRNA-122 predicts survival in patients with liver cirrhosis.

    Directory of Open Access Journals (Sweden)

    Oliver Waidmann

    Full Text Available BACKGROUND: Liver cirrhosis is associated with high morbidity and mortality. MicroRNAs (miRs circulating in the blood are an emerging new class of biomarkers. In particular, the serum level of the liver-specific miR-122 might be a clinically useful new parameter in patients with acute or chronic liver disease. AIM: Here we investigated if the serum level of miR-122 might be a prognostic parameter in patients with liver cirrhosis. METHODS: 107 patients with liver cirrhosis in the test cohort and 143 patients in the validation cohort were prospectively enrolled into the present study. RNA was extracted from the sera obtained at the time of study enrollment and the level of miR-122 was assessed. Serum miR-122 levels were assessed by quantitative reverse-transcription PCR (RT-PCR and were compared to overall survival time and to different complications of liver cirrhosis. RESULTS: Serum miR-122 levels were reduced in patients with hepatic decompensation in comparison to patients with compensated liver disease. Patients with ascites, spontaneous bacterial peritonitis and hepatorenal syndrome had significantly lower miR-122 levels than patients without these complications. Multivariate Cox regression analysis revealed that the miR-122 serum levels were associated with survival independently from the MELD score, sex and age. CONCLUSIONS: Serum miR-122 is a new independent marker for prediction of survival of patients with liver cirrhosis.

  2. NMR Detection of Semi-Specific Antibody Interactions in Serum Environments

    Directory of Open Access Journals (Sweden)

    Saeko Yanaka

    2017-09-01

    Full Text Available Although antibody functions are executed in heterogeneous blood streams characterized by molecular crowding and promiscuous intermolecular interaction, detailed structural characterizations of antibody interactions have thus far been performed under homogeneous in vitro conditions. NMR spectroscopy potentially has the ability to study protein structures in heterogeneous environments, assuming that the target protein can be labeled with NMR-active isotopes. Based on our successful development of isotope labeling of antibody glycoproteins, here we apply NMR spectroscopy to characterize antibody interactions in heterogeneous extracellular environments using mouse IgG-Fc as a test molecule. In human serum, many of the HSQC peaks originating from the Fc backbone exhibited attenuation in intensity of various magnitudes. Similar spectral changes were induced by the Fab fragment of polyclonal IgG isolated from the serum, but not by serum albumin, indicating that a subset of antibodies reactive with mouse IgG-Fc exists in human serum without preimmunization. The metaepitopes recognized by serum polyclonal IgG cover the entire molecular surface of Fc, including the binding sites to Fc receptors and C1q. In-serum NMR observation will offer useful tools for the detailed characterization of biopharamaceuticals, including therapeutic antibodies in physiologically relevant heterogeneous environments, also giving deeper insight into molecular recognition by polyclonal antibodies in the immune system.

  3. Evaluation and association of serum iron and ferritin levels in children with dental caries.

    Science.gov (United States)

    Venkatesh Babu, N S; Bhanushali, Parin Vasant

    2017-01-01

    Iron deficiency anemia accounts for 90% of all types of anemia in the world. Although the prevalence has declined in recent years, it remains an important pediatric public health problem. Iron deficiency has also been associated with dental caries. It impairs salivary gland function causing reduced salivary secretion and buffering capacity leading to increased caries activity. The aim of the study is to explore an association between dental caries and serum levels of iron and ferritin in children aged 3-12 years. Subjectsand Methods: The study group included 120 children, hospitalized for uncomplicated medical problems. Blood reports were evaluated to determine serum iron and ferritin levels. Dental caries experience was assessed using deft index. The collected data were tabulated and analyzed using Student's t-test and Pearson's correlation coefficient. Out of 120 children, 38 children showed low serum iron levels of which 31 children had dental caries and nine out of 15 children in the high serum iron level group showed dental caries. High ferritin levels were seen in three children among which two children were caries-free and only one child had a low ferritin level who also had a positive deft score. Based on the results, it was concluded that there is an inverse association between serum iron levels and dental caries whereas there is no association between serum ferritin levels and dental caries.

  4. Comprehensive characterisation of pulmonary and serum surfactant protein D in COPD

    Directory of Open Access Journals (Sweden)

    Erpenbeck Veit J

    2011-03-01

    Full Text Available Abstract Background Pulmonary surfactant protein D (SP-D is considered as a candidate biomarker for the functional integrity of the lung and for disease progression, which can be detected in serum. The origin of SP-D in serum and how serum concentrations are related to pulmonary concentrations under inflammatory conditions is still unclear. Methods In a cross-sectional study comprising non-smokers (n = 10, young - (n = 10, elderly smokers (n = 20, and smokers with COPD (n = 20 we simultaneously analysed pulmonary and serum SP-D levels with regard to pulmonary function, exercise, repeatability and its quaternary structure by native gel electrophoresis. Statistical comparisons were conducted by ANOVA and post-hoc testing for multiple comparisons; repeatability was assessed by Bland-Altman analysis. Results In COPD, median (IQR pulmonary SP-D levels were lower (129(68 ng/ml compared to smokers (young: 299(190, elderly: 296(158 ng/ml; p Conclusions Pulmonary and serum SP-D levels are stable markers influenced by smoking and related to airflow obstruction and disease state. Smaller subunits of pulmonary SP-D and the rapid increase of serum SP-D levels in COPD due to exercise support the translocation hypothesis and its use as a COPD biomarker. Trial registration no interventional trial

  5. Relation between serum creatinine and postoperative results of open-heart surgery.

    Science.gov (United States)

    Ezeldin, Tamer H

    2013-10-01

    To determine the impact of preoperative serum creatinine level in non-dialyzable patients on postoperative morbidity and mortality. This is a prospective study, where serum creatinine was used to give primary assessment on renal function status preoperatively. This study includes 1,033 patients, who underwent coronary artery bypass grafting, or valve(s) operations. The study took place at Al-Hada Military Hospital, Taif, Kingdom of Saudi between May 2008 and January 2012. Data were statistically analyzed using Chi square (x2) test and multivariable logistic regression, to evaluate the postoperative morbidity and mortality risks associated with low serum creatinine levels. Postoperative mortality increased with high serum creatinine level >1.8 mg/dL (pcreatinine level of more than 1.8 mg/dL was associated with increased risk of re-operation for bleeding, postoperative renal failure, prolonged ventilatory support, ICU stay, and total hospital stay. Perioperative serum creatinine is strongly related to post operative morbidity and mortality in open heart surgery. High serum creatinine in non-dialyzable patients can predict the increased morbidity and mortality after cardiac operations.

  6. Clinical investigation of serum CEA in 120 patients with colorectal cancer

    International Nuclear Information System (INIS)

    Li Yusheng; Yang Liting; Yu Yunyun; Yu Suqing; Ma Shuqin

    2003-01-01

    To investigate the correlation between serum CEA and colorectal cancer, the pre-and postoperative serum CEA in 120 patients with colorectal cancer was measured by RIA, with other 24 cases of healthy donors as control. The results showed that serum CEA in control group and patient group were 9.84±2.44 ng/mL, 38, 85±19.21 ng/mL respectively, while colonic cancer group 37.43±18.58 ng/mL, rectal cancer group 39.72±20.67 ng/mL. There was significant difference between patient group and control group (P 0.05). Serum CEA of 37 among 44 cases with positive CEA findings decreased to 11.21±3.65 ng/mL during two months follow-up post-operation, whereas 50.63±24.38 ng/mL in 7/44 cases undergoing non-radical operation. The serum CEA of 41 recurrence cases was 43.12±17.15 ng/mL at six-year post-operation, with 87.80% of three-year recurrence rate. It suggested that the serum CEA test is a convenient method for colorectal cancer to preoperatively diagnose it, evaluate postoperative curative effect and detect tumor recurrence and metastasis

  7. A Routine 'Top-Down' Approach to Analysis of the Human Serum Proteome.

    Science.gov (United States)

    D'Silva, Arlene M; Hyett, Jon A; Coorssen, Jens R

    2017-06-06

    Serum provides a rich source of potential biomarker proteoforms. One of the major obstacles in analysing serum proteomes is detecting lower abundance proteins owing to the presence of hyper-abundant species (e.g., serum albumin and immunoglobulins). Although depletion methods have been used to address this, these can lead to the concomitant removal of non-targeted protein species, and thus raise issues of specificity, reproducibility, and the capacity for meaningful quantitative analyses. Altering the native stoichiometry of the proteome components may thus yield a more complex series of issues than dealing directly with the inherent complexity of the sample. Hence, here we targeted method refinements so as to ensure optimum resolution of serum proteomes via a top down two-dimensional gel electrophoresis (2DE) approach that enables the routine assessment of proteoforms and is fully compatible with subsequent mass spectrometric analyses. Testing included various fractionation and non-fractionation approaches. The data show that resolving 500 µg protein on 17 cm 3-10 non-linear immobilised pH gradient strips in the first dimension followed by second dimension resolution on 7-20% gradient gels with a combination of lithium dodecyl sulfate (LDS) and sodium dodecyl sulfate (SDS) detergents markedly improves the resolution and detection of proteoforms in serum. In addition, well established third dimension electrophoretic separations in combination with deep imaging further contributed to the best available resolution, detection, and thus quantitative top-down analysis of serum proteomes.

  8. Decreased serum Ou/Zn sOD in children with Autism

    Directory of Open Access Journals (Sweden)

    A.J. Russo

    2009-01-01

    Full Text Available Aim To assess serum Cu/Zn SOD (Superoxide Dismutase concentration in autistic children and evaluate its possible relationship to GI Symptoms. Subjects and Methods Serum from 50 autistic children (31 with chronic digestive disease (most with ileo-colonic lymphoid nodular hyperplasia (LNH and inflammation of the colorectal, small bowel and/or stomach and 19 autistic children without GI disease, and 29 non autistic controls (20 age matched non autistic children with no GI disease and 9 age matched non autistic children with GI disease were tested for Cu/Zn SOD using ELISAs. Results Serum Cu/Zn SOD levels of autistic children were significantly lower than all non autistic controls (p < 0.0001. Serum Cu/Zn SOD of autistic children with severe GI disease was significantly lower than autistic children with no GI disease (p < 0.0001, non autistic children without GI disease (<0.0001 and non autistic children with GI disease (p = 0.0003. Discussion These results suggest an association between Cu/Zn SOD serum levels and autism, particularly autistic children with GI disease, and that the concentration of serum Cu/Zn SOD may be a useful biomarker for autistic children with severe GI disease.

  9. Tumor, serum and urine carcinoembryonic antigen (CEA) in upper urinary tract urothelial cancer

    International Nuclear Information System (INIS)

    Stefanovic, V.; Ignjatovic, M.

    1987-01-01

    The aim of this investigation was to study the possible diagnostic value of a CEA test in cancer of the renal pelvis and ureter. Thirty-eight patients with upper urinary tract cancer, 15 patients with transitional cell carcinoma of the bladder, 6 kidney carcinoma patients and 25 healthy adults were studied. CEA was determined in tumor tissue, serum and urine, by using a monoclonal radioimmunoassay. Increased serum CEA level was found in 7 out of 27 patients (26%) with active cancer of the renal pelvis and ureter. None of 11 patients with inactive cancer had an increased serum CEA level. No significant correlation was found between the serum CEA level and the histological grading. The tumor CEA content varied markedly, from values obtainted in normal urothelium up to 840 ng/g wet weight. CEA content of tumor tissue did not correlate with the serum level. Our data suggest that serum and urine CEA have not diagnostic accuracy for clinical diagnosis of upper tract urothelial cancer. (orig.) [de

  10. The correlation of serum asymmetric dimethylarginine and anti-Müllerian hormone in primary dysmenorrhea

    Directory of Open Access Journals (Sweden)

    Nermin Akdemir

    2016-08-01

    Full Text Available In this study, we aimed to investigate the association of serum asymmetric dimethylarginine (ADMA and anti-Müllerian hormone (AMH levels in primary dysmenorrhea patients. The study employed a cross-sectional design. Eighty-nine female university students with primary dysmenorrhea were included in the study. All patients underwent complete clinical and laboratory investigations, including serum ADMA, AMH levels, pelvic ultrasonography, electrocardiography, and echocardiography. Pearson correlation and linear regression analysis were used to evaluate associations between continuous data. Categorical associations were evaluated using χ2 test. Correlation analysis between serum ADMA and AMH levels in the study group showed a highly significant positive relationship (Pearson correlation = 0.978, p = 0.01. Our study has shown a significant positive correlation between serum ADMA and AMH levels in primary dysmenorrhea. Serum ADMA levels may have the potential to demonstrate ovarian reserve.

  11. Purification of a protein from serum of cattle with hepatic lipidosis, and identification of the protein as haptoglobin.

    Science.gov (United States)

    Yoshino, K; Katoh, N; Takahashi, K; Yuasa, A

    1992-06-01

    A protein that has 2 subunits with molecular weight of 35,000 and 23,000 was detected in serum of cattle with hepatic lipidosis (fatty liver). The protein was purified from serum obtained from a cow with fatty liver, and was identified as haptoglobin, which is known to have hemoglobin-binding capacity and to be an acute-phase protein. To assess the relevance of haptoglobin in fatty liver, cattle were classified in 3 groups (healthy control, haptoglobin-positive, and haptoglobin-negative); liver triglyceride content and several serum biochemical variables were evaluated for the 3 groups. Compared with the control and haptoglobin-negative cattle, haptoglobin-positive cattle had significantly (P less than 0.01) higher liver triglyceride content, serum bilirubin concentration, and aspartate transaminase activity. Serum haptoglobin concentration was high in slaughter cattle (27 of 40 cattle tested), particularly in cows (20/28).

  12. Serum protein capillary electrophoresis and measurement of acute phase proteins in a captive cheetah (Acinonyx jubatus) population

    DEFF Research Database (Denmark)

    Depauw, Sarah; Delanghe, Joris; Whitehouse-Tedd, Katherine

    2014-01-01

    Renal and gastrointestinal pathologies are widespread in the captive cheetah (Acinonyx jubatus) population but are often diagnosed at a late stage, because diagnostic tools are limited to the evaluation of clinical signs or general blood examination. Presently, no data are available on serum...... proteins and acute-phase proteins in cheetahs during health or disease, although they might be important to improve health monitoring. This study aimed to quantify serum proteins by capillary electrophoresis in 80 serum samples from captive cheetahs, categorized according to health status and disease type....... Moreover, serum amyloid A concentrations were measured via a turbidimetric immunoassay validated in domestic cats, whereas haptoglobin and C-reactive protein were determined by non-species-specific functional tests. Cheetahs classified as healthy had serum protein and acute phase protein concentrations...

  13. Smoking Discriminately Changes the Serum Active and Non-Active Forms of Vitamin B12

    Directory of Open Access Journals (Sweden)

    Niloofar Shekoohi

    2017-08-01

    Full Text Available Smoking may modify the appetite, and consequently affect nutrient intake and serum micronutrients. The effect of smoking on vitamin B12 status has been considered in several studies. The research proposed that organic nitrites, nitro oxide, cyanides, and isocyanides of cigarette smoke interfere with vitamin B12 metabolism, and convert it to inactive forms. This research was carried out to determine the serum level of active and inactive forms of vitamin B12 in male smokers in comparison with male nonsmokers. This is a case-control study, in which the participants were 85 male smokers and 85 male nonsmokers. The serum levels of total and active form of vitamin B12 were measured. Dietary intake was recorded by a quantitative food frequency questionnaire and one-day 24-hour dietary recall method. Independent two sample T test was used to compare quantitative variables between the case and control groups. The serum level of total vitamin B12 was not significantly different between two groups, but serum level of active form of vitamin B12 in the smoking group was significantly lower than non-smoking group (P<0.001. This is one of the first studies that evaluated the serum level of active form of vitamin B12 in smokers in the Iranian community. The results of this study identified that serum level of total vitamin B12 might be not different between smoking and non-smoking people, but the function of this vitamin is disturbed in the body of smokers through the reduction of serum level of active form of vitamin B12.

  14. Intrahepatic cholangiocarcinoma prognostic determination using pre-operative serum C-reactive protein levels

    International Nuclear Information System (INIS)

    Lin, Zi-Ying; Liang, Zhen-Xing; Zhuang, Pei-Lin; Chen, Jie-Wei; Cao, Yun; Yan, Li-Xu; Yun, Jing-Ping; Xie, Dan; Cai, Mu-Yan

    2016-01-01

    Serum C-reactive protein (CRP), an acute inflammatory response biomarker, has been recognized as an indicator of malignant disease progression. However, the prognostic significance of CRP levels collected before tumor removal in intrahepatic cholangiocarcinoma requires further investigation. We sampled the CRP levels in 140 patients with intrahepatic cholangiocarcinoma who underwent hepatectomies with regional lymphadenectomies between 2006 and 2013. A retrospective analysis of the clinicopathological data was performed. We focused on the impact of serum CRP on the patients’ cancer-specific survival and recurrence-free survival rates. High levels of preoperative serum CRP were significantly associated with well-established clinicopathologic features, including gender, advanced tumor stage, and elevated carcinoembryonic antigen and carbohydrate antigen 19-9 levels (P < 0.05). Univariate analysis demonstrated a significant association between high levels of serum CRP and adverse cancer-specific survival (P = 0.001) and recurrence-free survival (P < 0.001). In patients with stage I/II intrahepatic cholangiocarcinoma, the serum CRP level was a prognostic indicator for cancer-specific survival. In patients with stage I/II or stage III/IV, the serum CRP level was a prognostic indicator for recurrence-free survival (P < 0.05). Additionally, multivariate analysis identified serum CRP level in intrahepatic cholangiocarcinoma as an independent prognostic factor (P < 0.05). We confirmed a significant association of elevated pre-operative CRP levels with poor clinical outcomes for the tested patients with intrahepatic cholangiocarcinoma. Our results indicate that the serum CRP level may represent a useful factor for patient stratification in intrahepatic cholangiocarcinoma management

  15. Serum immunoglobulin levels predict fibrosis in patients with non-alcoholic fatty liver disease.

    Science.gov (United States)

    McPherson, Stuart; Henderson, Elsbeth; Burt, Alastair D; Day, Christopher P; Anstee, Quentin M

    2014-05-01

    A third of the population are estimated to have NAFLD of varying severity. Serum immunoglobulins are frequently elevated in patients with chronic liver disease, but little is known about serum immunoglobulin levels in patients with NAFLD. Aim of this study was to evaluate serum immunoglobulin levels (IgA, IgG, and IgM) in a large cohort of patients with biopsy-proven NAFLD and determine if immunoglobulin levels are associated with clinical or histological features. Patients seen in a tertiary fatty liver clinic between 1999 and 2009 were included. Liver biopsies were assessed using the Kleiner score. Immunoglobulin levels and other blood tests were taken at time of biopsy. 285 patients (110 simple steatosis and 175 NASH) had serum immunoglobulins measured within 6months of liver biopsy. 130 (46%) patients had elevated (>1× upper limit of normal) serum IgA levels, 28 (10%) patients had elevated IgG and 22 (8%) raised IgM. Serum IgA levels were elevated more frequently in patients with NASH compared with subjects with simple steatosis (55% vs. 31%, pliver fibrosis (Kleiner stage 3-4). There was a significant positive association between serum IgA levels and the stage of fibrosis (pfibrosis following multivariate analysis. A model constructed from these independent predictors accurately predicted advanced fibrosis (AUROC 0.87). The serum IgA level was frequently elevated in patients with NAFLD and was an independent predictor of advanced fibrosis. Copyright © 2014 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  16. Influence of Rifampin Therapy on Serum Bactericidal Activity in the Presence of Cloxacillin and Vancomycin

    Directory of Open Access Journals (Sweden)

    Andrew MR Mackenzie

    1990-01-01

    Full Text Available In this study the effect of rifampin on serum inhibitory and serum bactericidal titres was examined. Sera were prepared from pooled human serum to contain vancomycin (10 mg/L, cloxacillin (5 mg/L or rifampin (1 mg/L, and the combinations cloxacillin/rifampin and vancomycin/rifampin. These five sera were tested by a microtitre method for serum inhibitory power and serum bactericidal titre against 11 strains of Staphylococcus aureus. A 48 h incubation period was required to detect full colony growth for subculture plates. It was found with all strains that the effect of the addition of rifampin to the other two antibiotics was to increase the serum inhibitory power, lower the serum bactericidal titre, increase the inhibitory/cidal ratio, and slow colony growth on subculture. In the clinical part of the study it was shown that only three of 38 sera (8% from patients receiving betalactam or vanomycin but not rifampin gave an inhibitory/cidal ratio greater than 8, but that nine of 10 sera (90% from patients receiving rifampin in addition to betalactam or vancomycin gave a ratio greater than 8 (P<0.001. The study verified that the effect of rifampin in serum was to increase inhibitory power and decrease bactericidal titre. The clinical significance of these results is not known and it is suggested that a high ratio of inhibitory to bactericidal titre in the presence of rifampin is to be expected, and that a low bactericidal titre under these circumstances is not necessarily an indication to modify therapy.

  17. Hepatic lipidosis in anorectic, lactating holstein cattle: a retrospective study of serum biochemical abnormalities.

    Science.gov (United States)

    Cebra, C K; Garry, F B; Getzy, D M; Fettman, M J

    1997-01-01

    The association between hepatic lipidosis (HL) and disease in 59 anorectic, ketotic, lactating Holstein heifers and cows was investigated. Severe HL, as determined by histologic evaluation of liver tissue, was present in 46 animals; only half of these animals required intensive treatment for ketosis, and only half had serum biochemical evidence of liver disease, as determined by the presence of a last value of 2-fold or greater than the upper limit of the reference ranges for at least 2 of the 4 serum tests: gamma-glutamyl transferase, aspartate aminotransferase, and sorbitol dehydrogenase activities and bile acid concentrations. Most cattle with biochemical evidence of liver disease and severe HL had been lactating for 14 or more days. Cows that required intensive treatment inconsistently had serum biochemical evidence of liver disease. Although cattle with severe HL had significantly higher serum bilirubin concentrations and aspartate aminotransferase and sorbitol dehydrogenase activities than cattle with less severe lipidosis, the specificity of abnormally high serum sorbitol dehydrogenase activity or bilirubin concentration for severe lipidosis was only 8%. Abnormally high serum aspartate aminotransferase activity was 83% sensitive and 62% specific for severe lipidosis. Serum glucose and total carbon dioxide concentrations were significantly lower in cattle with severe lipidosis than in those with mild or moderate lipidosis, and low serum glucose or total carbon dioxide concentrations were rare in cattle without severe lipidosis. From these data, we conclude that the use of a single biochemical or histopathologic criterion to define severity of disease or degree of liver compromise in anorectic, ketotic cows results in the misidentification of many animals.

  18. Simultaneous radioimmunoassay for corticosterone and deoxycortisol in human serum: Sex differences in the mean serum concentrations

    International Nuclear Information System (INIS)

    Schoeneshoefer, M.; Harendt, H.; Vecsei, P.

    1977-01-01

    A specific radioimmunoassay is described which allows the simultaneous determination of serum corticosterone and deoxycortisol. The normal serum concentration of both steroids were found to be dependent on sex and menstrual cycle. Mean concentrations (+-S.D.) in males, females (follicular phase) and females (luteal phase) were 4210 +- 2170 ng/l, 2410 +- 1480 ng/l and 4390 +- 2320 ng/l for corticosterone and 499 +- 273 ng/l, 207 +- 152 ng/l and 335 +- 182 ng/l for deoxycortisol. After adrenal stimulation by corticotropin itself or by insulin induced hypoglycemia, the serum concentrations of corticosterone became significantly higher than those of deoxycortisol. After oral administration of dexamethasone serum concentrations of both steroids were suppressed to levels below the limit of the normal range. One hour after oral metyrapone administration at midnight, serum corticosterone decreased, while serum deoxycortisol increased by a factor of about five. After eight hours serum concentrations of both steroids were increased considerably. Corticosterone attained levels slightly higher than the normal range and deoxycortisol rose to levels which were higher than the normal mean concentrations by a factor of about 500. (orig./AS) [de

  19. Positive Impact of Nutritional Interventions on Serum Symmetric Dimethylarginine and Creatinine Concentrations in Client-Owned Geriatric Cats.

    Directory of Open Access Journals (Sweden)

    Jean A Hall

    Full Text Available A prospective study was conducted in client-owned geriatric cats to evaluate the short- term effects of a test food on serum symmetric dimethylarginine (SDMA and creatinine (Cr concentrations. Test food contained functional lipids (fish oil, antioxidants (vitamins C and E, L-carnitine, botanicals (vegetables, highly bioavailable protein, and amino acid supplements. Cats (n = 80 were fed either test food or owner's-choice foods (non-nutritionally controlled cohort. Cats were included based on age (≥ 9 years, indoor only, neutered, and free of chronic disease. At baseline, all cats had serum Cr concentrations within the reference interval. Renal function biomarkers and urinalysis results at baseline and after consuming test food or owner's-choice foods for 3 and 6 months were evaluated. Cats consuming test food showed significant decreases in serum Cr and BUN concentrations across time. Overall, cats consuming owner's-choice foods showed significant increases in serum SDMA concentrations at 3 and 6 months compared with baseline (P ≤ 0.05, whereas in cats consuming test food serum SDMA concentrations did not change. At baseline or during the 6-month feeding trial, 23 (28.8% cats had increased serum SDMA, but normal serum Cr consistent with IRIS Stage 1 chronic kidney disease. This included 6 cats fed test food and 17 cats fed owner's-choice foods. In the 6 cats fed test food, serum SDMA decreased in 3 cats and remained stable in 1 cat, whereas in the 17 cats fed owner's-choice foods, serum SDMA increased in 13 cats and decreased or remained stable in 4 cats. The increase in serum SDMA concentration was significant (P = 0.02 only for cats fed owner's-choice foods. These results suggest that nonazotemic cats with elevated serum SDMA (early renal insufficiency when fed a food designed to promote healthy aging are more likely to demonstrate stable renal function compared with cats fed owner's-choice foods. Cats fed owner's-choice foods were more

  20. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  1. Abnormalities of the five serum ions in patients with Leber congenital amaurosis

    Directory of Open Access Journals (Sweden)

    Zhi-Zhong Wu

    2017-03-01

    Full Text Available AIM:To study the concentration changes of the serum magnesium, calcium, potassium, sodium and chloride ions of the patients of Leber congenital amaurosis(LCA.METHODS:Based on the retrospective study and the simple size in the statistics, 50 cases of LCA patients and 99 cases of normal people were tested the serum ions by professionals in hospital according to the single blind study. Data were analyzed statistically between LCA and normal groups. RESULTS: In the clinical serum ions test of LCA group, the concentration of calcium and potassium were 2.338±0.090mmol/L and 4.164±0.356mmol/L respectively, which were significantly higher than those of the normal group(all PPP>0.05. CONCLUSION: In the patients with LCA, abnormal concentration changes of magnesium, calcium and potassium will be needed to concern of the ophthalmologist, which is probably related with the occurrence of LCA.

  2. Hematological and Serum Biochemical Parameters of Weanling ...

    African Journals Online (AJOL)

    The objective of this study was to determine the dose-dependent effect of medroxyprogesterone acetate on hematology and serum biochemistry in weanling dogs. Nine healthy local dogs between 12 to 14 weeks of age were randomly assigned to three treatments: control, 150mg/kg and 300mg/kg of medroxyprogesterone ...

  3. Serum and urine trace metals in ketosis

    Energy Technology Data Exchange (ETDEWEB)

    Burch, R.E.; Hiner, C.; Sullivan, J.F.

    1974-01-01

    Three groups of male rats were housed in metabolic cages. The control group was fed ad libitum, a second group was fasted and diabetes was induced in the third group by the subcutaneous injection of alloxan. After 48 hours all animals were bled and livers, which were quick-frozen in situ, were obtained. Fasted and diabetic animals were ketotic as manifested by lowering urinary pH and elevated urinary and blood acetoacetate and ..beta..-hydroxybutyrate. Blood and hepatic content of acetate was elevated in diabetic versus control rats. Blood and hepatic content of acetate was not increased in fasted animals. In fasted rats total urinary Zn and Cu were decreased and Mg and Ca did not differ significantly from control values. In diabetic rats total urinary excretion of Mg was increased whereas urinary Zn, Cu and Ca levels did not differ significantly from control values. In fasted animals only serum Zn was diminished. In diabetic rats serum Cu and Ca were decreased and serum Mg was increased while serum Zn was unchanged. Thus, the ketosis of fasting differs from the ketosis of diabetes in several of its metabolic manifestations. 11 references, 9 figures.

  4. PERFLUORINATED COMPOUNDS (PFCs) IN SERUM OF ...

    Science.gov (United States)

    The PFCs have been used in a wide range of consumer, including residential, products (e.g., stain-resistant coatings for carpets and upholstery). Carbon-fluoride bonds are highly stable, mak-ing PFCs extremely resistant to biodegradation. Thus, PFCs have become globally distributed and are ubiquitously present in serum of wildlife and people. Despite this, comparatively little is known as to how people are primarily exposed, and what (if any) health risk is associated with chronic, low-level exposure. It is hypothesized that house dust may represent a significant exposure route because PFCs can slough or volatilize from products used indoors, subsequently adsorbing to and accumulating within house dust. The purpose of this study was to determine if PFC serum levels in domestic cats tended to increase in proportion to time spent indoors and whether analyte patterns reflected that of food sources [e.g., fish products with high perfluoro-octane sulfonate (PFOS) but low perfluorohexanesulfonate (PFHxS)] or with house dust (PFOS + PFHxS + perfluorooctanoate (PFOA) ─ with high PFHxS levels in the most contaminated dust). In 2008, serum was obtained from feral and pet cats presenting to shelters and clinics in the Raleigh, NC area, including the NCSU VTH. PFC serum levels were measured using high-resolution time-of-flight mass spectroscopy. Data on housing status was available for 50 cats. From least to greatest indoor residential exposure, cats were grouped as

  5. Serum chromium levels in gestational diabetes mellitus

    Directory of Open Access Journals (Sweden)

    P G Sundararaman

    2012-01-01

    Full Text Available Objective: To measure serum chromium level in women with gestational diabetes mellitus (GDM from Chennai, South India. Materials and Methods: Thirty women with gestational diabetes, 60 age matched controls. Inclusion criteria: Gestational age 22-28 weeks, age group 20-35 years. Exclusion Criteria: Gestational age beyond 28 weeks, malnutrition or presence of infection. Serum chromium was measured using inductive couple plasma emission spectrometer. Results: Serum chromium levels of women with GDM, 1.59+/-0.02 ng/ml (range: 0.16-4.0 ng/ml were lower than in controls (4.58+/-0.62 ng/ml; range 0.82-5.33 ng/ml (P < 0.001. However, there were no significant differences among cases and controls when subdivided by parity. Conclusions: Women with GDM from a South Indian city had lower levels of serum chromium compared to pregnant women without GDM. Studies may be done whether chromium supplementation is useful in this group of women.

  6. Serum YKL-40 and colorectal cancer

    DEFF Research Database (Denmark)

    Cintin, C; Johansen, J S; Christensen, Ib Jarle

    1999-01-01

    related to short survival. In the present study we analysed YKL-40 in preoperative sera from patients with colorectal cancer and evaluated its relation to survival. Serum YKL-40 was determined by RIA in 603 patients. Survival after operation was registered, and median follow-up time was 61 months. Three...

  7. Biodegradable nanoporous nanoparticles for human serum analysis

    International Nuclear Information System (INIS)

    Pujia, A.; De Angelis, F.; Scumaci, D.; Gaspari, M.; Liberale, C.; Candeloro, P.; Cuda, G.; Di Fabrizio, E.

    2010-01-01

    Modern medicine and biology search for new powerful tool for biomarkers discovery, appears one of the most promising approaches for early cancer diagnosis. Nowadays, the low molecular weight fraction of human serum is the most informative source of biomarkers, but their study and identification are very difficult due to the incredible complexity of the raw human serum. In this work we describe a novel tool for the filtration of crude human serum or other bio-fluid based on water soluble nanoparticles. Nanoparticles with a pore size of about 2-3 nm, and diameters of 200 nm were obtained by ultrasonication of nanoporous silicon. The porous nanoparticles act as a nanosieve able to exclusively harvest the low molecular weight fraction of the fluid thanks to a controllable pore size. After a short incubation, the infiltrated nanosieves can be extracted from the starting fluid by means of centrifugation, and dissolved in water in a few minutes to give the captured molecules back in their native state, without degradation and contamination. The raw fluid is so split in two components of high and low molecular weight, that are both available for further analyses with any other investigation technique. Here, fluorescence spectroscopy, 2D-gel electrophoresis, and mass spectrometry are exploited to show the split of different bio-fluids under physiological condition. A cut-off (or split level) of 13 kDa is demonstrated also for human serum.

  8. Oral cancer screening: serum Raman spectroscopic approach

    Science.gov (United States)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  9. Comparison of Serum Calcium and Magnesium Between ...

    African Journals Online (AJOL)

    Background: Evidence suggests the involvement of calcium and magnesium metabolism in the pathophysiology of preeclampsia. However, findings from studies are heterogenous and inconsistent. Aim: The study aimed to compare the total serum calcium and magnesium levels in preeclamptic women with that of ...

  10. Expression and characterization of recombinant human serum ...

    African Journals Online (AJOL)

    C-peptide (CP), connecting the A and B chains in proinsulin, has been considered to possess physiological effects in diabetes. In order to prolong the half-life of CP in vivo, a long acting CP analog [human serum albumin (HSA-CP)] was obtained by direct gene fusion of a single-chain CP to HSA and expressed in host ...

  11. Preliminary Studies on Some Haematological and Serum ...

    African Journals Online (AJOL)

    The mean serum values of sodium, potassium, chloride and bicarbonate, as well as urea, creatinine and alanine aminotransferase(ALT) enzyme did not differ from the normal values, while the mean aspartate aminotransferase (AST) enzyme value appeared to be lower than the normal range.In conclusion, the RBC, PCV ...

  12. gene polymorphism and its serum lev

    Indian Academy of Sciences (India)

    Navya

    polymorphisms and its serum level with the risk of MetS as well as their ... population for quantifying insulin resistance and β-cell function (Matthews et al. 1985). .... of IL-10 -819 C >T gene polymorphism (Co-dominant model) was significantly.

  13. Haematology, serum biochemistry and growth performance of ...

    African Journals Online (AJOL)

    High performing does have the tendency of producing healthy kids with reasonable weight at birth compared to least performing does. A study was conducted to investigate the haematology, serum biochemistry and growth performance of grazing pregnant Kalahari Red does fed concentrate diets at three protein levels.

  14. Serum Iron Protects from Renal Postischemic Injury.

    Science.gov (United States)

    Vaugier, Céline; Amano, Mariane T; Chemouny, Jonathan M; Dussiot, Michael; Berrou, Claire; Matignon, Marie; Ben Mkaddem, Sanae; Wang, Pamella H M; Fricot, Aurélie; Maciel, Thiago T; Grapton, Damien; Mathieu, Jacques R R; Beaumont, Carole; Peraldi, Marie-Noëlle; Peyssonnaux, Carole; Mesnard, Laurent; Daugas, Eric; Vrtovsnik, François; Monteiro, Renato C; Hermine, Olivier; Ginzburg, Yelena Z; Benhamou, Marc; Camara, Niels O S; Flamant, Martin; Moura, Ivan C

    2017-12-01

    Renal transplants remain a medical challenge, because the parameters governing allograft outcome are incompletely identified. Here, we investigated the role of serum iron in the sterile inflammation that follows kidney ischemia-reperfusion injury. In a retrospective cohort study of renal allograft recipients ( n =169), increased baseline levels of serum ferritin reliably predicted a positive outcome for allografts, particularly in elderly patients. In mice, systemic iron overload protected against renal ischemia-reperfusion injury-associated sterile inflammation. Furthermore, chronic iron injection in mice prevented macrophage recruitment after inflammatory stimuli. Macrophages cultured in high-iron conditions had reduced responses to Toll-like receptor-2, -3, and -4 agonists, which associated with decreased reactive oxygen species production, increased nuclear localization of the NRF2 transcription factor, increased expression of the NRF2-related antioxidant response genes, and limited NF- κ B and proinflammatory signaling. In macrophage-depleted animals, the infusion of macrophages cultured in high-iron conditions did not reconstitute AKI after ischemia-reperfusion, whereas macrophages cultured in physiologic iron conditions did. These findings identify serum iron as a critical protective factor in renal allograft outcome. Increasing serum iron levels in patients may thus improve prognosis of renal transplants. Copyright © 2017 by the American Society of Nephrology.

  15. Performance, immunity, serum biochemical and hematological ...

    African Journals Online (AJOL)

    ... results suggest that supplementing broilers' diet with 5 g/kg thyme can indicate favorable influences of antibiotic growth promoter on performance without any detrimental impacts on immune responses and blood parameters. Key words: Broiler, thyme, growth performance, immunity, serum biochemistry, hematology.

  16. Hypoxemia increases serum interleukin-6 in humans

    DEFF Research Database (Denmark)

    Klausen, T; Olsen, Niels Vidiendal; Poulsen, T D

    1997-01-01

    Serum concentrations of interleukin (IL) 1 beta, IL-1 receptor antagonist (IL-1ra), IL-6, tumor necrosis factor (TNF) alpha, and C-reactive protein (CRP) were determined in ten healthy men at sea level and during four days of altitude hypoxia (4350m above sea level). The mean (SD) arterial blood...

  17. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  18. Serum irisin levels in patients with psoriasis.

    Science.gov (United States)

    Baran, Anna; Myśliwiec, Hanna; Kiluk, Paulina; Świderska, Magdalena; Flisiak, Iwona

    2017-06-01

    Irisin has been proposed to regulate metabolic diseases such as obesity, diabetes or metabolic syndrome which are common comorbidities in psoriasis. The aim of this study was to evaluate the serum irisin level in psoriasis and elucidate possible associations with disease activity, inflammatory or metabolic parameters and topical treatment. Thirty-seven individuals with active plaque-type psoriasis and 15 healthy controls were enrolled. Blood samples were collected before and after two weeks of therapy. Serum irisin concentrations were examined by enzyme-linked immunosorbent assay (ELISA). The results were correlated with psoriasis area and severity index (PASI), body mass index (BMI), inflammatory and biochemical markers, lipid profile and effectiveness of topical treatment. Irisin serum levels were insignificantly increased in psoriatic patients in comparison to the controls (p = 0.38). No significant correlations between investigated adipokine and several indicators of metabolic disorders, nor BMI (p = 0.37) or PASI (p = 0.5) were found. Significant positive correlations with C-reactive protein (CRP) (0.009), lipocalin-2 (p = 0.02), age (p = 0.02) and disease duration (p = 0.008) were noted. After topical treatment, serum irisin level did not significantly change (p = 0.31), despite clinical improvement. Irisin might be a marker of inflammation in psoriatic patients, but may not be a reliable indicator of metabolic conditions, severity of psoriasis nor efficacy of antipsoriatic treatment.

  19. Serum Calcium, Inorganic Phosphates and some Haematological ...

    African Journals Online (AJOL)

    Objectives: Sickle cell disease has long been associated with bone deformities and pain. Mineral salts such as calcium and inorganic phosphate are critical in bone formation and metabolism. This investigation was designed to study the serum concentration of these minerals as well as some haematological parameters in ...

  20. Anaerobic exercise - Induced changes in serum mineral ...

    African Journals Online (AJOL)

    Anaerobic exercise, a non 02 – dependent energy metabolism leads to transient metabolic changes, which are corrected gradually by homestatic mechanism. We investigated in eight male subjects, the effects of anaerobic exercise after a day sedentary activity on serum mineral concentration. There was significant ...

  1. Serum erythropoietin levels by radioimmunoassay in polycythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Birgegaard, G.; Miller, O.; Caro, J.; Erslev, A. (Cardeza Foundation for Hematological Research, Jefferson University, Philadelphia, Pa.)

    1982-01-01

    A radioimmunoassay (RIA) method for erythropoietin (Epo) was developed and validated against the polycythaemic mouse assay. The correlation was good, with a r=0.94. Several other criteria of specificity were also filled by the RIA, which had a lower detection limit of 5 mU/ml. The mean serum-Epo level in 6 patients with secondary polycythaemia, 50.2 +- 26.2 mU/ml, was significantly higher than in a group of 11 normal subjects, 28.7 +- 7.2 mU/ml (P<0.0002). However, the Epo level in 31 polycythaemia vera (PV) patients, M = 21.9 +- 6.6 mU/ml, was not significantly different from normal (P = 0.006). Since previous studies with bioassay of heat-treated and concentrated plasma samples have shown a decreased serum-Epo level in PV, Epo levels were measured before and after heat treatment and concentration of samples from normals and polycythaemics. It was found that the levels of immunoreactive material increased after heat treatment and 40 times concentration in samples from normals and patients with secondary polycythaemias, but decreased in PV. We conclude that the Epo levels in serum in the low range measured by our and previous RIA:s probably are not true Epo levels but are partly due to an unspecific serum effect, that was removed by heat treatment.

  2. Immunoreactive somatomedin A in human serum

    International Nuclear Information System (INIS)

    Hall, K.; Brandt, J.; Enberg, G.; Fryklund, L.

    1979-01-01

    A RIA has been developed for somatomedin A (SM-A) utilizing Sepharose-bound antibodies. This assay, measuring SM-A, the insulin-like growth factors 1 and 2, and somatomedin C, allows determination in serum samples. In comparison with a serum standard, the mean serum levels in patients with acromegaly or GH deficiency and healthy subjects were 8.7 +- 0.7 (n=25), 0.24 +- 0.02 (n=25), and 1.15 +- 0.11 U/ml, respectively. The correlation coefficient between immunoreactive SM-A and SM-A by radioreceptor assay was highly significant (r=0.93), although the potency ratio of SM-A between the two groups of patients was higher in the RIA than in the radioreceptor assay. Gel chromatography revealed that SM-A in acromegalic serum is bound to a carrier protein which is absent in patients with GH deficiency. After gel chromatography at low pH, 90% of applied immunoreactive SM-A was recovered in the low molecular weight fraction and consisted mainly of neutral polypeptides

  3. Aggregation and fibrillation of bovine serum albumin

    DEFF Research Database (Denmark)

    Holm, NK; Jespersen, SK; Thomassen, LV

    2007-01-01

    The all-alpha helix multi-domain protein bovine serum albumin (BSA) aggregates at elevated temperatures. Here we show that these thermal aggregates have amyloid properties. They bind the fibril-specific dyes Thioflavin T and Congo Red, show elongated although somewhat worm-like morphology...

  4. Expression and characterization of recombinant human serum ...

    African Journals Online (AJOL)

    ajl yemi

    2011-11-14

    Nov 14, 2011 ... C-peptide (CP), connecting the A and B chains in proinsulin, has been considered to possess physiological effects in diabetes. In order to prolong the half-life of CP in vivo, a long acting CP analog. [human serum albumin (HSA-CP)] was obtained by direct gene fusion of a single-chain CP to HSA and.

  5. Comparative serum biochemistry of captive mugger crocodiles ...

    African Journals Online (AJOL)

    Standard serum biochemical parameters were determined for 28 mugger crocodiles (Crocodylus palustris) using Supra-occipital plexus technique and/or Cardiocentesis technique at the Arignar Anna Zoological Park, Vandalur, Chennai, Guindy Snake Park Trust and Amaravathy Crocodile farm, Tamilnadu, India (13° 0´ N; ...

  6. Maternal serum fructosamine values after delivery ofmacrosomic ...

    African Journals Online (AJOL)

    expl.anation for this discrepancy is that the half-lives of these. 1. Brudenell M, Wilds PLo Medical and Surgical Problems in Obstetrics. Bristol: John Wright, 1984: 120-124. 2. Baker JR, O'Connor JP, Metcalf P, Lawson MR, Johnson RN. Oinical usefulness of estimation of serum frucrosamine concentration as a screening.

  7. Radioassay for serum and red cell folate

    International Nuclear Information System (INIS)

    Longo, D.L.; Herbert, V.

    1976-01-01

    A simple, reliable assay for serum and red cell folate is described. It uses plain untreated liquid or powdered milk, requiring no special handling or purification, as binder. Such milk makes it possible to ignore endogenous serum folate binder, since crude (but not purified) milk contains a factor which releases folate from serum binder. It simplifies counting radioactivity by employing a gamma emitting isotope of pteroylglutamic acid (PGA), namely the 125 I-tyramide of PGA. Like the 3 H-PGA assay of Givas and Gutcho, it permits the use of stable PGA rather than unstable methyltetrahydrofolic acid (MeTHFA) standards, because it is carried out at pH 9.3, a pH at which milk folate binder is unable to distinguish PGA from MeTHFA, which is the predominant folate in human tissues. The equipment required to do the radioassay is present in most diagnostic chemistry laboratories. Results are essentially identical to the generally accepted Lactobacillus casei microbiologic method of folate assay, except that false low results are not produced in the radioassay by antibiotics, tranquilizers, and chemotherapeutic agents. Three caveats in its use are the relative instability of 125 I-PGA as compared to 3 H-PGA, the fact that various powdered milks differ widely in folate-binding capacity, and that only about 60 percent of commercially obtained skim or powdered milk preparations appear to contain the substance which splits folate from serum binder

  8. Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation.

    Science.gov (United States)

    Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2013-07-01

    Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American

  9. Serum CCL-18 level is a risk factor for COPD exacerbations requiring hospitalization

    Science.gov (United States)

    Dilektasli, Asli Gorek; Demirdogen Cetinoglu, Ezgi; Uzaslan, Esra; Budak, Ferah; Coskun, Funda; Ursavas, Ahmet; Ercan, Ilker; Ege, Ercument

    2017-01-01

    Introduction Chemokine (C-C motif) ligand 18 (CCL-18) has been shown to be elevated in chronic obstructive pulmonary disease (COPD) patients. This study primarily aimed to evaluate whether the serum CCL-18 level differentiates the frequent exacerbator COPD phenotype from infrequent exacerbators. The secondary aim was to investigate whether serum CCL-18 level is a risk factor for exacerbations requiring hospitalization. Materials and methods Clinically stable COPD patients and participants with smoking history but normal spirometry (NSp) were recruited for the study. Modified Medical Research Council Dyspnea Scale, COPD Assessment Test, spirometry, and 6-min walking test were performed. Serum CCL-18 levels were measured with a commercial ELISA Kit. Results Sixty COPD patients and 20 NSp patients were recruited. Serum CCL-18 levels were higher in COPD patients than those in NSp patients (169 vs 94 ng/mL, PCOPD (168 vs 196 ng/mL) subgroups did not achieve statistical significance (P=0.09). Serum CCL-18 levels were significantly higher in COPD patients who had experienced at least one exacerbation during the previous 12 months. Overall, ROC analysis revealed that a serum CCL-18 level of 181.71 ng/mL could differentiate COPD patients with hospitalized exacerbations from those who were not hospitalized with a 88% sensitivity and 88.2% specificity (area under curve: 0.92). Serum CCL-18 level had a strong correlation with the frequency of exacerbations requiring hospitalization (r=0.68, PCOPD, as it is associated with frequency of exacerbations, particularly with severe COPD exacerbations requiring hospitalization, as well as with functional parameters and symptom scores. PMID:28115842

  10. Serum levels of vitamin A, visual function and ocular surface after bariatric surgery

    Directory of Open Access Journals (Sweden)

    Luana Paula Nogueira de Araújo BRANDÃO

    Full Text Available ABSTRACT BACKGROUND Bariatric surgery is the most effective treatment for severe obesity, but the surgery increases the risk of developing nutritional deficiencies, such as vitamin A deficiency. In human metabolism, vitamin A plays a role in vision. OBJECTIVE To evaluate serum vitamin A, visual function and ocular surface of patients undergoing bariatric surgery. METHODS A cross-sectional and analytical study was conduced with 28 patients undergoing bariatric surgery for at least 6 months. Ophthalmologic evaluation was done through color vision test, contrast sensitivity test, ocular surface tests and confocal microscopy, as well as vitamin A serum measurement. RESULTS Vertical sleeve gastrectomy was performed in seven (25.0% patients and Roux -en-Y gastric by-pass in 21 (75.0%. Mean serum vitamin A level was 1.7±0.5 µmoL/L. Most patients (60.7% had symptoms of dry eye. Five (17.9% patients had contrast sensitivity impairment and 18 (64.3% color vision changes. In the group of patients undergoing Roux -en-Y gastric by-pass , mean vitamin A levels were 1.8±0.6 µmoL/L, whereas they were 1.7±0.5 µmoL/L in patients submitted to the restrictive technique vertical sleeve gastrectomy . The analysis of the influence of serum levels of vitamin A in the visual function and ocular surface was performed by Pearson correlation test and there was no significant correlation between any of the variables and vitamin A. CONCLUSION There was no influence of the bariatric surgery technique used on serum vitamin A levels, on the visual function or on the ocular surface. Moreover, there was no correlation between serum levels of vitamin A and the visual function or the ocular surface changes.

  11. Reliable clinical serum analysis with reusable electrochemical sensor: Toward point-of-care measurement of the antipsychotic medication clozapine.

    Science.gov (United States)

    Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F

    2017-09-15

    Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Gender and age influence the relationship between serum GH and IGF-I in patients with acromegaly.

    Science.gov (United States)

    Parkinson, C; Renehan, A G; Ryder, W D J; O'Dwyer, S T; Shalet, S M; Trainer, P J

    2002-07-01

    In patients with acromegaly serum IGF-I is increasingly used as a marker of disease activity. As a result, the relationship between serum GH and IGF-I is of profound interest. Healthy females secrete three times more GH than males but have broadly similar serum IGF-I levels, and women with GH deficiency require 30-50% more exogenous GH to maintain the same serum IGF-I as GH-deficient men. In a selected cohort of patients with active acromegaly, studied off medical therapy using a single fasting serum GH and IGF-I measurement, we have reported previously that, for a given GH level, women have significantly lower circulating IGF-I. To evaluate the influence of age and gender on the relationship between serum GH and IGF-I in an unselected cohort of patients with acromegaly independent of disease control and medical therapy. Sixty (34 male) unselected patients with acromegaly (median age 51 years (range 24-81 years) attending a colonoscopy screening programme were studied. Forty-five had previously received pituitary radiotherapy. Patients had varying degrees of disease control and received medical therapy where appropriate. Mean serum GH was calculated from an eight-point day profile (n = 45) and values obtained during a 75-g oral glucose tolerance test (n = 15). Serum IGF-I, IGFBP-3 and acid-labile subunit were measured and the dependency of these factors on covariates such as log10 mean serum GH, sex, age and prior radiotherapy was assessed using regression techniques. The median calculated GH value was 4.7 mU/l (range 1-104). A significant linear association was observed between serum IGF-I and log10 mean serum GH for the cohort (R = 0.5, P fall by 0.37 nmol/l per year (P = 0.04, 95% CI 0.015-0.72). In keeping with previous observations of relative GH resistance in normal and GH-deficient females we have observed lower serum IGF-I levels for equivalent mean serum GH levels in females patients with acromegaly. This gender-dependent difference is independent of

  13. Prognostic significance of serum bilirubin in stroke

    International Nuclear Information System (INIS)

    Arslan, A.; Ismail, M.; Khan, F.; Khan, A.; Khattak, M.B.; Anwar, M.J.

    2011-01-01

    Background: Oxidative injury is an important cause of the neurologic lesion in stroke. Serum bilirubin is considered a natural antioxidant that may affect the prognosis of stroke. The purpose of this study was to evaluate the prognostic significance of bilirubin in stroke patients. Methods: A prospective cross-sectional study was conducted in Medical Units of Khyber Teaching Hospital, Peshawar. Inpatients admitted with acute attack of stroke were included in this study. Data regarding serum bilirubin and concurrent cerebrovascular risk factors were collected. National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) were used to analyse stroke's severity and functional outcomes, respectively. Results: Hypertension, diabetes mellitus and heart diseases were the most common risk factors. Patients were divided into 3 groups on the basis of serum bilirubin, i.e., =0.6 mg/dl (Group-1), 0.7-0.9 mg/dl (Group-2), and =1.0 mg/dl (Group-3). The mean pre-hospitalisation NIHSS score for Groups 1, 2 and 3 was 5.62, 11.66 and 25.33, respectively; and post-hospitalisation score was 0.875, 3.76 and 16.26, respectively. The pre-hospitalisation mRS score was 4 for Group-1, 4.52 for Group-2 and 4.93 for Group-3; while post-hospitalisation Mrs Score was 1.50, 2.38 and 4.26, respectively. Average serum bilirubin level was significantly higher in patients with poor outcomes as compared with good outcomes (p<0.01). Conclusions: This study suggests that higher serum bilirubin levels were associated with increased stroke severity, longer hospitalisation and poor prognosis. (author)

  14. Can common serum biomarkers predict complicated appendicitis in children?

    Science.gov (United States)

    Zani, Augusto; Teague, Warwick J; Clarke, Simon A; Haddad, Munther J; Khurana, Sanjeev; Tsang, Thomas; Nataraja, Ramesh M

    2017-07-01

    As appendicitis in children can be managed differently according to the severity of the disease, we investigated whether commonly used serum biomarkers on admission could distinguish between simple and complicated appendicitis. Admission white blood cell (WBC), neutrophil (NEU), and C-reactive protein (CRP) levels were analysed by ROC curve, and Kruskal-Wallis and contingency tests. Patients were divided according to age and histology [normal appendix (NA), simple appendicitis (SA), complicated appendicitis (CA)]. Of 1197 children (NA = 186, SA = 685, CA = 326), 7% were 40 mg/L in 58% CA and 37% SA (p 15 × 10 9 /L in 58% CA and 43% SA (p appendicitis in children older than 5 years of age. Early distinction of appendicitis severity using these tests may guide caregivers in the preoperative decision-making process.

  15. Evaluation of serum sialic acid, fucose levels and their ratio in oral squamous cell carcinoma.

    Science.gov (United States)

    Chinnannavar, Sangamesh Ningappa; Ashok, Lingappa; Vidya, Kodige Chandrashekhar; Setty, Sunil Mysore Kantharaja; Narasimha, Guru Eraiah; Garg, Ranjana

    2015-01-01

    Detection of cancer at the early stage is of utmost importance to decrease the morbidity and mortality of the disease. Apart from the conventional biopsy, minimally invasive methods like serum evaluation are used for screening large populations. Thus, this study aimed to estimate serum levels of sialic acid and fucose and their ratio in oral cancer patients and in healthy control group to evaluate their role in diagnosis. Serum samples were collected from 52 healthy controls (group I) and 52 squamous cell carcinoma patients (group II). Estimation of serum levels of sialic acid and fucose and their ratio was performed. This was correlated histopathologically with the grades of carcinoma. Statistical analysis was done by using analysis of variance (ANOVA) test and unpaired "t" test. Results showed that serum levels of sialic acid and fucose were significantly higher in oral cancer patients compared to normal healthy controls (P ratio was significantly lower in cancer patients than in normal controls (P ratio showed decreasing trend from controls to malignant group. The ratio of sialic acid to fucose can be a useful diagnostic aid for oral cancer patients.

  16. A fast and reproducible method for albumin isolation and depletion from serum and cerebrospinal fluid.

    Science.gov (United States)

    Holewinski, Ronald J; Jin, Zhicheng; Powell, Matthew J; Maust, Matthew D; Van Eyk, Jennifer E

    2013-03-01

    Analysis of serum and plasma proteomes is a common approach for biomarker discovery, and the removal of high-abundant proteins, such as albumin and immunoglobins, is usually the first step in the analysis. However, albumin binds peptides and proteins, which raises concerns as to how the removal of albumin could impact the outcome of the biomarker study while ignoring the possibility that this could be a biomarker subproteome itself. The first goal of this study was to test a new commercially available affinity capture reagent from Protea Biosciences and to compare the efficiency and reproducibility to four other commercially available albumin depletion methods. The second goal of this study was to determine if there is a highly efficient albumin depletion/isolation system that minimizes sample handling and would be suitable for large numbers of samples. Two of the methods tested (Sigma and ProteaPrep) showed an albumin depletion efficiency of 97% or greater for both serum and cerebrospinal fluid (CSF). Isolated serum and CSF albuminomes from ProteaPrep spin columns were analyzed directly by LC-MS/MS, identifying 128 serum (45 not previously reported) and 94 CSF albuminome proteins (17 unique to the CSF albuminome). Serum albuminome was also isolated using Vivapure anti-HSA columns for comparison, identifying 105 proteins, 81 of which overlapped with the ProteaPrep method. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Serum interleukin-6 is related to lower cognitive functioning in elderly patients with major depression.

    Science.gov (United States)

    Ali, Nehad Samir; Hashem, Abdel Hamid Hashem; Hassan, Akmal Mostafa; Saleh, Alia Adel; El-Baz, Heba Nabil

    2018-05-01

    There is an increased evidence of an association between inflammatory mediators, particularly serum IL-6, depression and cognitive impairment in the elderly. This study aims at exploring the relation of peripheral IL-6 to cognitive functions in elderly patients with major depressive disorder (MDD). (1) Assessment of serum IL-6 levels and cognitive functions in elderly patients suffering from major depression and comparing them to healthy age-matched control subjects; (2) correlation between serum IL-6 levels and clinical characteristics of depression and cognitive functions in these patients. The study is an observational, case-control study. It consisted of 80 subjects, 40 with the diagnosis of MDD according to the Diagnostic and Statistical Manual of Mental Disorders (DSM IV-TR) with early onset (first episode before the age of 60) and 40 community-dwelling subjects. They were subjected to the Structured Clinical Interview according to DSM-IV, Montreal Cognitive Assessment, Montgomery Asberg Depression Rating Scale, and serum IL-6 assay using ELISA. In the depression group, subjects had lower scores in cognitive testing, than the control group (p = 0.001). Serum IL-6 was found to have a negative correlation with cognitive testing in these patients even after controlling for the severity of depressive status and Body Mass Index (BMI) (p = 0.025). MDD in elderly subjects is associated with decline in cognitive functions that may be related to peripheral IL-6 levels.

  18. Gender difference of serum angiotensin-converting enzyme (ACE) activity in DD genotype of ACE insertion/deletion polymorphism in elderly Chinese.

    Science.gov (United States)

    Zhang, Ya-Feng; Cheng, Qiong; Tang, Nelson L S; Chu, Tanya T W; Tomlinson, Brian; Liu, Fan; Kwok, Timothy C Y

    2014-12-01

    In this study we investigated the gender difference of serum angiotensin-converting enzyme (ACE) activity in a population of Hong Kong-dwelling elderly Chinese. A total of 1767 (843 male, 924 female) Hong Kong-dwelling elderly Chinese were recruited. ACE I/D genotypes were identified by polymerase chain reaction amplification and serum ACE activity was determined using a commercially available kinetic kit. ACE I/D genotype distribution was compared by chi-square test, the correlation between ACE I/D polymorphism and serum ACE activity was analysed by ANOVA test and gender difference of serum ACE activity of different genotypes was compared by independent sample t-test. No statistically significant difference of genotype distribution between male and female subjects was found. Serum ACE activity was significantly correlated with ACE genotype. Overall, there was no gender difference of serum ACE activity; however, when sub-grouping the subjects by ACE I/D genotype, male subjects with DD genotype had higher serum ACE activity than female subjects with DD genotype. No significant gender difference of genotype distribution was found in elderly Chinese. Serum ACE activity was significantly correlated with ACE I/D polymorphism in elderly Chinese. Male subjects with DD genotype had higher serum ACE activity than female subjects with DD genotype. © The Author(s) 2013.

  19. TSH (Thyroid-stimulating hormone) test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Thyroid-Stimulating Hormone, Serum; p. 484. ...

  20. A Large, Cross-sectional Observational Study of Serum BDNF, Cognitive Function, and Mild Cognitive Impairment in the Elderly

    Directory of Open Access Journals (Sweden)

    Hiroyuki eShimada

    2014-04-01

    Full Text Available Objective: The clinical relationship between brain-derived neurotrophic factor (BDNF and cognitive function or mild cognitive impairment (MCI is not well understood. The purpose of this study was to identify the relationship between serum BDNF and cognitive function and MCI, and determine whether serum BDNF level might be a useful biomarker for assessing risk for MCI in older people.Materials and Methods: A total of 4463 individuals aged 65 years or older (mean age 72 years participating in the study. We measured performance in a battery of neuropsychological and cognitive function tests; serum BDNF concentration.Results: Eight hundred twenty-seven participants (18.8% had MCI. After adjustment for sex, age, education level, diabetes, and current smoking, serum BDNF was associated with poorer performance in the story memory, and digit symbol substitution task scores. Serum BDNF was marginally associated with the presence of MCI (OR, 95% CI: 1.41, 1.00–1.99 when BDNF was 1.5 SD lower than the mean value standardized for sex and age, education level, diabetes, and current smoking.Conclusion: Low serum BDNF was associated with lower cognitive test scores and MCI. Future prospective studies should establish the discriminative value of serum BDNF for the risk of MCI.