WorldWideScience

Sample records for serum creatinine scr

  1. Role of serum creatinine for screening renal diseases

    International Nuclear Information System (INIS)

    Younas, M.; Khan, F.A.; Sattar, A.; Kazmi, A.

    2011-01-01

    Chronic kidney disease (CKD) is a public Heath problem with increasing prevalence in Pakistan. Early identification of mild renal disease can delay its progression. Glomerular filtration rate (GFR) is the best overall index of renal function, but it is difficult to measure, so mostly clinicians rely on. serum creatinine (SCr) concentration which its own limitations. On the other hand 24 hours (h) urinary creatinine clearance (CICl) is a more sensitive marker of renal dysfunction. Presently SCr is being used in our clinical practice to screen the renal diseases which can miss mild renal dysfunctions, so this study was designed to calculate frequency of individuals having reduced GFR as determined by CrCI having normal SCr levels. (author)

  2. Urinary creatinine to serum creatinine ratio and renal failure index in dogs infected with Babesia canis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga; Wesołowska, Agnieszka; Wędrychowicz, Halina

    2013-09-01

    Urinary creatinine to serum creatinine (UCr/SCr) ratio and renal failure index (RFI) are useful indices of renal damage. Both UCr/SCr ratio and RFI are used in differentiation between prerenal azotaemia and acute tubular necrosis. In this work the authors calculated the UCr/SCr ratio and RFI in dogs infected with Babesia canis and the values of these indices in azotaemic dogs infected with the parasite. The results of this study showed significantly lower UCr/SCr ratio in dogs infected with B. canis than in healthy dogs. Moreover, in azotaemic dogs infected with B. canis the UCr/SCr ratio was significantly lower and the RFI was significantly higher than in non-azotaemic dogs infected with B. canis. The calculated correlation between RFI and duration of the disease before diagnosis and treatment was high, positive and statistically significant (r = 0.89, p caused by B. canis in Poland acute tubular necrosis may develop.

  3. The urinary excretion of metformin, ceftizoxime and ofloxacin in high serum creatinine rats: Can creatinine predict renal tubular elimination?

    Science.gov (United States)

    Ma, Yan-Rong; Zhou, Yan; Huang, Jing; Qin, Hong-Yan; Wang, Pei; Wu, Xin-An

    2018-03-01

    The renal excretion of creatinine and most drugs are the net result of glomerular filtration and tubular secretion, and their tubular secretions are mediated by individual transporters. Thus, we hypothesized that the increase of serum creatinine (SCr) levels attributing to inhibiting tubular transporters but not glomerular filtration rate (GFR) could be used to evaluate the tubular excretion of drugs mediated by identical or partial overlap transporter with creatinine. In this work, we firstly developed the creatinine excretion inhibition model with normal GFR by competitively inhibiting tubular transporters, and investigated the renal excretion of metformin, ceftizoxime and ofloxacin in vivo and in vitro. The results showed that the 24-hour urinary excretion of metformin and ceftizoxime in model rats were decreased by 25% and 17% compared to that in control rats, respectively. The uptake amount and urinary excretion of metformin and ceftizoxime could be inhibited by creatinine in renal cortical slices and isolated kidney perfusion. However, the urinary excretion of ofloxacin was not affected by high SCr. These results showed that the inhibition of tubular creatinine transporters by high SCr resulted to the decrease of urinary excretion of metformin and ceftizoxime, but not ofloxacin, which implied that the increase of SCr could also be used to evaluate the tubular excretion of drugs mediated by identical or partial overlap transporter with creatinine in normal GFR rats. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Reference intervals for serum cystatin C and creatinine of an ...

    African Journals Online (AJOL)

    Background and Aim: Estimation of the glomerular filtration rate (GFR) is important for the evaluation of patients with kidney disease. Some studies suggest that GFR estimated from serum cystatin C (Cys C) is more accurate than that from serum creatinine (SCr). For Cys C to be used for this purpose, normal values need to ...

  5. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  6. Does NGAL reduce costs? A cost analysis of urine NGAL (uNGAL) & serum creatinine (sCr) for acute kidney injury (AKI) diagnosis.

    Science.gov (United States)

    Parikh, Amay; Rizzo, John A; Canetta, Pietro; Forster, Catherine; Sise, Meghan; Maarouf, Omar; Singer, Eugenia; Elger, Antje; Elitok, Saban; Schmidt-Ott, Kai; Barasch, Jonathon; Nickolas, Thomas L

    2017-01-01

    Urine neutrophil gelatinase-associated lipocalin (uNGAL) is a sensitive and specific diagnostic test for acute kidney injury (AKI) in the Emergency Department (ED), but its economic impact has not been investigated. We hypothesized that uNGAL used in combination with serum creatinine (sCr) would reduce costs in the management of AKI in patients presenting to the ED in comparison to using sCr alone. A cost simulation model was developed for clinical algorithms to diagnose AKI based on sCr alone vs. uNGAL plus sCr (uNGAL+sCr). A cost minimization analysis was performed to determine total expected costs for patients with AKI. uNGAL test characteristics were validated with eight-hundred forty-nine patients with sCr ≥1.5 from a completed study of 1635 patients recruited from EDs at two U.S. hospitals from 2007-8. Biomarker test, AKI work-up, and diagnostic imaging costs were incorporated. For a hypothetical cohort of 10,000 patients, the model predicted that the expected costs were $900 per patient (pp) in the sCr arm and $950 in the uNGAL+sCr arm. uNGAL+sCr resulted in 1,578 fewer patients with delayed diagnosis and treatment than sCr alone (2,013 vs. 436 pts) at center 1 and 1,973 fewer patients with delayed diagnosis and treatment than sCr alone at center 2 (2,227 vs. 254 patients). Although initial evaluation costs at each center were $50 pp higher in with uNGAL+sCr, total costs declined by $408 pp at Center 1 and by $522 pp at Center 2 due to expected reduced delays in diagnosis and treatment. Sensitivity analyses confirmed savings with uNGAL + sCr for a range of cost inputs. Using uNGAL with sCr as a clinical diagnostic test for AKI may improve patient management and reduce expected costs. Any cost savings would likely result from avoiding delays in diagnosis and treatment and from avoidance of unnecessary testing in patients given a false positive AKI diagnosis by use of sCr alone.

  7. Does NGAL reduce costs? A cost analysis of urine NGAL (uNGAL & serum creatinine (sCr for acute kidney injury (AKI diagnosis.

    Directory of Open Access Journals (Sweden)

    Amay Parikh

    Full Text Available Urine neutrophil gelatinase-associated lipocalin (uNGAL is a sensitive and specific diagnostic test for acute kidney injury (AKI in the Emergency Department (ED, but its economic impact has not been investigated. We hypothesized that uNGAL used in combination with serum creatinine (sCr would reduce costs in the management of AKI in patients presenting to the ED in comparison to using sCr alone.A cost simulation model was developed for clinical algorithms to diagnose AKI based on sCr alone vs. uNGAL plus sCr (uNGAL+sCr. A cost minimization analysis was performed to determine total expected costs for patients with AKI. uNGAL test characteristics were validated with eight-hundred forty-nine patients with sCr ≥1.5 from a completed study of 1635 patients recruited from EDs at two U.S. hospitals from 2007-8. Biomarker test, AKI work-up, and diagnostic imaging costs were incorporated.For a hypothetical cohort of 10,000 patients, the model predicted that the expected costs were $900 per patient (pp in the sCr arm and $950 in the uNGAL+sCr arm. uNGAL+sCr resulted in 1,578 fewer patients with delayed diagnosis and treatment than sCr alone (2,013 vs. 436 pts at center 1 and 1,973 fewer patients with delayed diagnosis and treatment than sCr alone at center 2 (2,227 vs. 254 patients. Although initial evaluation costs at each center were $50 pp higher in with uNGAL+sCr, total costs declined by $408 pp at Center 1 and by $522 pp at Center 2 due to expected reduced delays in diagnosis and treatment. Sensitivity analyses confirmed savings with uNGAL + sCr for a range of cost inputs.Using uNGAL with sCr as a clinical diagnostic test for AKI may improve patient management and reduce expected costs. Any cost savings would likely result from avoiding delays in diagnosis and treatment and from avoidance of unnecessary testing in patients given a false positive AKI diagnosis by use of sCr alone.

  8. Correlation between glomerular filtration rate with gamma camera and estimated serum creatinine clearance from Cockcroft and Gault's formula

    International Nuclear Information System (INIS)

    Bhushan, Shivanand; Kumar, Rajesh

    2012-01-01

    The purpose of the present study is to find out the correlation between the glomerular filtration rate (GFR by Gates gamma camera method) and serum creatinine clearance (SCrCl by Cockcroft and Gault's method) within ± 3 weeks’ time difference. Study design retrospectively in 59 patients with serum creatinine value calculated for SCrCl with Cockcroft and Gault's formula as an index parameter for kidney function underwent the 99m-Technitium labeled Di-ethyl Triamine Penta Acetic Acid (99mTc-DTPA) renogram with ECIL planar gamma camera. All data of 59 patients has been divided into Group- I, II, and III based on the time difference of serum creatinine test from 99mTc-DTPA renal GFR tests performed on the same subjects. Serum Creatinine test was carried out within ± 3 days, between ± 4 days and ± 7 days, and between ± 8 days and ± 21 days from the DTPA GFR Test performed in the Group-I, II, and III respectively. Correlation coefficient of Group-I (n = 15) patients showed 0.8198 and P value < 0.001 for GFR and S. Creatinine within ± 3 days. Group-II (n = 17) and Group-III (n = 27) patients having correlation coefficient 0.6194 and 0.589 and P value <0.01 respectively, within ± 21 days. The two methods gave almost identical estimate of GFR even at 3 weeks interval. Study concludes that SCrCl using Cockcroft and Gault's formula could serve as an instant, easy, and reliable method for assessing kidney function. SCrCl with Cockcroft and Gault's formula is more useful for rapid estimation of global GFR for those patients who are not accessible to DTPA renogram with gamma camera. Correlation can be established further with the prospective study in various renal pathophysiological conditions

  9. Clinical evaluation of analytical variations in serum creatinine measurements : why laboratories should abandon Jaffe techniques

    NARCIS (Netherlands)

    Drion, Iefke; Cobbaert, Christa; Groenier, Klaas H.; Weykamp, Cas; Bilo, Henk J. G.; Wetzels, Jack F. M.; Kleefstra, Nanne

    2012-01-01

    Background: Non-equivalence in serum creatinine (SCr) measurements across Dutch laboratories and the consequences hereof on chronic kidney disease (CKD) staging were examined. Methods: National data from the Dutch annual external quality organization of 2009 were used. 144 participating laboratories

  10. Transporters affecting biochemical test results: Creatinine-drug interactions.

    Science.gov (United States)

    Chu, X; Bleasby, K; Chan, G H; Nunes, I; Evers, R

    2016-11-01

    Creatinine is eliminated by the kidneys through a combination of glomerular filtration and active transport. Drug-induced increases in serum creatinine (SCr) and/or reduced creatinine renal clearance are used as a marker for acute kidney injury. However, inhibition of active transport of creatinine can result in reversible and, therefore, benign increases in SCr levels. Herein, the transporters involved in creatinine clearance are discussed, in addition to limitations of using creatinine as a biomarker for kidney damage. © 2016 American Society for Clinical Pharmacology and Therapeutics.

  11. Lack of Serum Creatinine Decrease After Coronary Angiography Despite Prophylactic Hydration After Routine Coronary Angiography/Angioplasty in Stable Angina Patients--Pilot Study.

    Science.gov (United States)

    Burchardt, Pawel; Rzezniczak, Janusz; Synowiec, Tomasz; Angerer, Dariusz; Palasz, Anna; Zurawski, Jakub

    2016-01-01

    To prevent contrast induced renal dysfunction a periprocedural prophylactic hydration is applied. Due to dilution it should cause a drop in serum creatinine concentration (SCR). Surprisingly, no reduction in SCR after contrast admission is found in up to 25% of patients as early as 12-18 hours after coronary angiography/angioplasty. This study aims to find a clinical explanation as well as predict circumstances for this phenomenon. Retrospective clinical and laboratory data was used from 341 patients who underwent elective coronary angiography/angioplasty, received a prophylactic hydration, and had serum creatinine concentration measured prior to, and 12-18 hours after invasive procedure with iodine contrast administration. To exclude an improper hydration due to no creatinine decrease, the number of red blood cells was analysed as well as hemoglobin and hematocrit in blood donations collected during the study time points. The resulting lack of serum creatinine reduction could be explained by dehydration (measured by increase in number of RBC, HGB and HCT) only in 13.5% , 10.8%, and 20% of cases, respectively. Any form of abnormal glucose metabolism combined with either baseline serum creatinine concentration creatinine clearance >86.77 mL/min, or GFR by CKD EPI >80.08 mL/min/1.73 m2, or GFR by MDRD >74.48 mL/min/1.73 m2 were the predictors for no creatinine decrease at outcome. Additionally, it was demonstrated that the lack of creatinine decrease was more often observed among those patients whose initial renal function was better than in the subjects with reduction of SCR. This observation requires further prospective investigation on extended group of patients. © 2016 The Author(s) Published by S. Karger AG, Basel.

  12. Serum creatinine and cystatin C provide conflicting evidence of acute kidney injury following acute ingestion of potassium permanganate and oxalic acid.

    Science.gov (United States)

    Wijerathna, Thilini Madushanka; Gawarammana, Indika Bandara; Dissanayaka, Dhammika Menike; Palanagasinghe, Chathura; Shihana, Fathima; Dassanayaka, Gihani; Shahmy, Seyed; Endre, Zoltan Huba; Mohamed, Fahim; Buckley, Nicholas Alan

    2017-11-01

    Acute kidney injury (AKI) is common following deliberate self-poisoning with a combination washing powder containing oxalic acid (H 2 C 2 O 4 ) and potassium permanganate (KMnO 4 ). Early and rapid increases in serum creatinine (sCr) follow severe poisoning. We investigated the relationship of these increases with direct nephrotoxicity in an ongoing multicenter prospective cohort study in Sri Lanka exploring AKI following poisoning. Multiple measures of change in kidney function were evaluated in 48 consenting patients who had serial sCr and serum cystatin C (sCysC) data available. Thirty-eight (38/48, 79%) patients developed AKI (AKIN criteria). Twenty-eight (58%) had AKIN stage 2 or 3. Initial increases in urine creatinine (uCr) excretion were followed by a substantial loss of renal function. The AKIN stage 2 and 3 (AKIN2/3) group had very rapid rises in sCr (a median of 118% at 24 h and by 400% at 72 h post ingestion). We excluded the possibility that the rapid rise resulted from the assay used or muscle damage. In contrast, the average sCysC increase was 65% by 72 h. In most AKI, sCysC increases to the same extent but more rapidly than sCr, as sCysC has a shorter half-life. This suggests either a reduction in Cystatin C production or, conversely, that the rapid early rise of sCr results from increased production of creatine and creatinine to meet energy demands following severe oxidative stress mediated by H 2 C 2 O 4 and KMnO 4 . Increased early creatinine excretion supports the latter explanation, since creatinine excretion usually decreases transiently in AKIN2/3 from other causes.

  13. Serum Creatinine: Not So Simple!

    Science.gov (United States)

    Delanaye, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). © 2017 S. Karger AG, Basel.

  14. Quantitative analysis of elevation of serum creatinine via renal transporter inhibition by trimethoprim in healthy subjects using physiologically-based pharmacokinetic model.

    Science.gov (United States)

    Nakada, Tomohisa; Kudo, Toshiyuki; Kume, Toshiyuki; Kusuhara, Hiroyuki; Ito, Kiyomi

    2018-02-01

    Serum creatinine (SCr) levels rise during trimethoprim therapy for infectious diseases. This study aimed to investigate whether the elevation of SCr can be quantitatively explained using a physiologically-based pharmacokinetic (PBPK) model incorporating inhibition by trimethoprim on tubular secretion of creatinine via renal transporters such as organic cation transporter 2 (OCT2), OCT3, multidrug and toxin extrusion protein 1 (MATE1), and MATE2-K. Firstly, pharmacokinetic parameters in the PBPK model of trimethoprim were determined to reproduce the blood concentration profile after a single intravenous and oral administration of trimethoprim in healthy subjects. The model was verified with datasets of both cumulative urinary excretions after a single administration and the blood concentration profile after repeated oral administration. The pharmacokinetic model of creatinine consisted of the creatinine synthesis rate, distribution volume, and creatinine clearance (CL cre ), including tubular secretion via each transporter. When combining the models for trimethoprim and creatinine, the predicted increments in SCr from baseline were 29.0%, 39.5%, and 25.8% at trimethoprim dosages of 5 mg/kg (b.i.d.), 5 mg/kg (q.i.d.), and 200 mg (b.i.d.), respectively, which were comparable with the observed values. The present model analysis enabled us to quantitatively explain increments in SCr during trimethoprim treatment by its inhibition of renal transporters. Copyright © 2017 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  15. Serum Creatinine: Not So Simple!

    OpenAIRE

    DELANAYE, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDM...

  16. A meta-analysis of genome-wide data from five European isolates reveals an association of COL22A1, SYT1, and GABRR2 with serum creatinine level

    NARCIS (Netherlands)

    C. Pattaro (Cristian); A. de Grandi (Alessandro); V. Vitart (Veronique); C. Hayward (Caroline); A. Franke (Andre); Y.S. Aulchenko (Yurii); A. Johansson (Åsa); S.H. Wild (Sarah); S.A. Melville (Scott); A.J. Isaacs (Aaron); O. Polasek (Ozren); D. Ellinghaus (David); I. Kolcic (Ivana); U. Nöthlings (Ute); L. Zgaga (Lina); T. Zemunik (Tatijana); C. Gnewuch (Carsten); S. Schreiber (Stefan); S. Campbell (Susan); N. Hastie (Nick); M. Boban (Mladen); T. Meitinger (Thomas); B.A. Oostra (Ben); P. Riegler (Peter); C. Minelli (Cosetta); A.F. Wright (Alan); H. Campbell (Harry); C.M. van Duijn (Cornelia); U. Gyllensten (Ulf); J.F. Wilson (James); M. Krawczak (Michael); I. Rudan (Igor); P.P. Pramstaller (Peter Paul)

    2010-01-01

    textabstractBackground: Serum creatinine (SCR) is the most important biomarker for a quick and non-invasive assessment of kidney function in population-based surveys. A substantial proportion of the inter-individual variability in SCR level is explicable by genetic factors.Methods: We performed a

  17. The Complexities of Interpreting Reversible Elevated Serum Creatinine Levels in Drug Development: Does a Correlation with Inhibition of Renal Transporters Exist?

    Science.gov (United States)

    Chu, Xiaoyan; Bleasby, Kelly; Chan, Grace Hoyee; Nunes, Irene; Evers, Raymond

    2016-09-01

    In humans, creatinine is formed by a multistep process in liver and muscle and eliminated via the kidney by a combination of glomerular filtration and active transport. Based on current evidence, creatinine can be taken up into renal proximal tubule cells by the basolaterally localized organic cation transporter 2 (OCT2) and the organic anion transporter 2, and effluxed into the urine by the apically localized multidrug and toxin extrusion protein 1 (MATE1) and MATE2K. Drug-induced elevation of serum creatinine (SCr) and/or reduced creatinine renal clearance is routinely used as a marker for acute kidney injury. Interpretation of elevated SCr can be complex, because such increases can be reversible and explained by inhibition of renal transporters involved in active secretion of creatinine or other secondary factors, such as diet and disease state. Distinction between these possibilities is important from a drug development perspective, as increases in SCr can result in the termination of otherwise efficacious drug candidates. In this review, we discuss the challenges associated with using creatinine as a marker for kidney damage. Furthermore, to evaluate whether reversible changes in SCr can be predicted prospectively based on in vitro transporter inhibition data, an in-depth in vitro-in vivo correlation (IVIVC) analysis was conducted for 16 drugs with in-house and literature in vitro transporter inhibition data for OCT2, MATE1, and MATE2K, as well as total and unbound maximum plasma concentration (Cmax and Cmax,u) data measured in the clinic. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  18. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    Science.gov (United States)

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  19. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    Science.gov (United States)

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; Psamples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  20. Cystatin C levels in healthy kidney donors and its correlation with GFR by creatinine clearance

    International Nuclear Information System (INIS)

    Ayub, S.; Khan, S.; Zafar, M.N.

    2014-01-01

    Objective: To determine Serum Cystatin C (S.CysC) levels in healthy potential kidney donors and its correlation with Serum Creatinine (S.Cr), Glomerular filtration rate (GFR) by 24 hour urinary Creatinine clearance (CCL) and GFR by formulae of Cockcroft Gault (CCG) and Modification of diet in Renal Disease (MDRD). Methods: A Cross sectional study was conducted at Sindh Institute of Urology and Transplantation (SIUT), Karachi, between June and December 2012. One hundred and three potential healthy kidney donors were enrolled in the study to measure their S.CysC and correlate it with S.Cr, CCL and GFR by CCG and MDRD. Statistical analysis was done by SPSS 17. Results: The mean age of the healthy kidney donors was 32.19+8.27 years with a M:F ratio of 1.86:1. The mean Serum Creatinine (S.Cr) was 0.86+0.18 mg/dl and mean S.CysC was 0.88+0.12 mg/dl. S.CysC showed significant correlation with S.Cr (r = 0.78, p<0.001), CCL (r = 0.67, p<0.001), GFR CCG (r = 0.54, p<0.001) and GFR MDRD (r = 0.67, p<0.001). Correlation of S.CysC was better than S.Cr for CCL, S.Cr (0.60) vs S.CysC (0.67) and GFR CCG, S.Cr (0.41) vs S.CysC (0.54). Correlation was comparable for MDRD, S.Cr (0.67) vs S.Cys (0.67). Conclusion: S.CysC is better marker of kidney function in potential healthy kidney donors. It is a reliable, convenient and economical marker that can be used especially in routine clinical practice. (author)

  1. A comparison of observed versus estimated baseline creatinine for determination of RIFLE class in patients with acute kidney injury

    NARCIS (Netherlands)

    Bagshaw, Sean M.; Uchino, Shigehiko; Cruz, Dinna; Bellomo, Rinaldo; Morimatsu, Hiroshi; Morgera, Stanislao; Schetz, Miet; Tan, Ian; Bouman, Catherine; Macedo, Etienne; Gibney, Noel; Tolwani, Ashita; Oudemans-van Straaten, Heleen M.; Ronco, Claudio; Kellum, John A.; French, Craig; Mulder, John; Pinder, Mary; Roberts, Brigit; Botha, John; Mudholkar, Pradeen; Holt, Andrew; Hunt, Tamara; Honoré, Patrick Maurice; Clerbaux, Gaetan; Schetz, Miet Maria; Wilmer, Alexander; Yu, Luis; Macedo, Ettiene V.; Laranja, Sandra Maria; Rodrigues, Cassio José; Suassuna, José Hermógenes Rocco; Ruzany, Frederico; Campos, Bruno; Leblanc, Martine; Senécal, Lynne; Gibney, R. T. Noel; Johnston, Curtis; Brindley, Peter; Tan, Ian K. S.; Chen, Hui De; Wan, Li; Rokyta, Richard; Krouzecky, Ales; Neumayer, Hans-Helmut; Detlef, Kindgen-Milles; Mueller, Eckhard; Tsiora, Vicky; Sombolos, Kostas; Mustafa, Iqbal; Suranadi, Iwayan; Bar-Lavie, Yaron; Nakhoul, Farid; Ceriani, Roberto; Bortone, Franco; Zamperetti, Nereo; Pappalardo, Federico; Marino, Giovanni; Calabrese, Prospero; Monaco, Francesco; Liverani, Chiara; Clementi, Stefano; Coltrinari, Rosanna; Marini, Benedetto; Fuke, Nobuo; Miyazawa, Masaaki; Katayama, Hiroshi; Kurasako, Toshiaki; Hirasawa, Hiroyuki; Oda, Shigeto; Tanigawa, Koichi; Tanaka, Keiichi; Oudemans-van Straaten, Helena Maria; de Pont, Anne-Cornelie J. M.; Bugge, Jan Frederik; Riddervold, Fridtjov; Nilsen, Paul Age; Julsrud, Joar; Teixeira e Costa, Fernando; Marcelino, Paulo; Serra, Isabel Maria; Yaroustovsky, Mike; Grigoriyanc, Rachik; Lee, Kang Hoe; Loo, Shi; Singh, Kulgit; Barrachina, Ferran; Llorens, Julio; Sanchez-Izquierdo-Riera, Jose Angel; Toral-Vazquez, Darío; Wizelius, Ivar; Hermansson, Dan; Gaspert, Tomislav; Maggiorini, Marco; Davenport, Andrew; Lombardi, Raúl; Llopart, Teresita; Venkataraman, Ramesh; Kellum, John; Murray, Patrick; Trevino, Sharon; Benjamin, Ernest; Hufanda, Jerry; Paganini, Emil; Warnock, David; Guirguis, Nabil

    2009-01-01

    The RIFLE classification scheme for acute kidney injury (AKI) is based on relative changes in serum creatinine (SCr) and on urine output. The SCr criteria, therefore, require a pre-morbid baseline value. When unknown, current recommendations are to estimate a baseline SCr by the MDRD equation.

  2. High-Density Lipoprotein Cholesterol, Blood Urea Nitrogen, and Serum Creatinine Can Predict Severe Acute Pancreatitis.

    Science.gov (United States)

    Hong, Wandong; Lin, Suhan; Zippi, Maddalena; Geng, Wujun; Stock, Simon; Zimmer, Vincent; Xu, Chunfang; Zhou, Mengtao

    2017-01-01

    Early prediction of disease severity of acute pancreatitis (AP) would be helpful for triaging patients to the appropriate level of care and intervention. The aim of the study was to develop a model able to predict Severe Acute Pancreatitis (SAP). A total of 647 patients with AP were enrolled. The demographic data, hematocrit, High-Density Lipoprotein Cholesterol (HDL-C) determinant at time of admission, Blood Urea Nitrogen (BUN), and serum creatinine (Scr) determinant at time of admission and 24 hrs after hospitalization were collected and analyzed statistically. Multivariate logistic regression indicated that HDL-C at admission and BUN and Scr at 24 hours (hrs) were independently associated with SAP. A logistic regression function (LR model) was developed to predict SAP as follows: -2.25-0.06 HDL-C (mg/dl) at admission + 0.06 BUN (mg/dl) at 24 hours + 0.66 Scr (mg/dl) at 24 hours. The optimism-corrected c-index for LR model was 0.832 after bootstrap validation. The area under the receiver operating characteristic curve for LR model for the prediction of SAP was 0.84. The LR model consists of HDL-C at admission and BUN and Scr at 24 hours, representing an additional tool to stratify patients at risk of SAP.

  3. Modeling Serum Creatinine in Septic ICU Patients

    DEFF Research Database (Denmark)

    De Gaetano, Andrea; Cortese, Giuliana; Pedersen, Morten Gram

    2004-01-01

    Serum creatinine is a metabolite assumed to be constantly produced by the normally functioning muscle mass and is a good measure for monitoring daily renal function in the intensive care unit (ICU). High serum creatinine levels or an abnormal departure from normal pre-disease basal levels....... The present work details the structure of a model describing observed creatinine serum concentration (CSC) variations, depending on the time-varying septic insult to renal function in ICU patients, as well as the estimation of its parameters. CSC determinations were routinely obtained from 12 patients...

  4. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  5. Detection and prognostic impact of renal dysfunction in patients with chronic heart failure and normal serum creatinine.

    Science.gov (United States)

    Scrutinio, Domenico; Passantino, Andrea; Lagioia, Rocco; Santoro, Daniela; Cacciapaglia, Erasmo

    2011-03-03

    Accurate identification of renal dysfunction (RD) is crucial to risk stratification in chronic heart failure (CHF). Patients with CHF are at special risk of having RD despite normal serum creatinine (SCr), owing to a decreased Cr generation. At low levels of SCr, the equations estimating renal function are less accurate. This study was aimed to assess and compare the prognostic value of formulas estimating renal function in CHF patients with normal SCr. We studied 462 patients with systolic CHF and normal SCr. Creatinine clearance was estimated by the Cockcroft-Gault (eCrCl) and glomerular filtration rate by the 4-variable MDRD equation (eGFR); eCrCl normalized for body-surface area (eCrCl(BSA)) was calculated. The primary outcome was all-cause mortality at 2 years. Seventy five patients died. At multivariate Cox regression analysis, only eCrCl(BSA) was significantly associated with mortality (p = 0.006); eGFR (p = 0.24), eCrCl (p = 0.09) and BUN (p = 0.14) were not statistically significant predictors. The patients in the lowest eCrCl(BSA) quartile had an adjusted 2.1-fold (CI: 1.06-4.1) increased risk of mortality, compared with those in the referent quartile. Two-year survival was 70.4% in the lowest eCrCl(BSA) quartile and 89.7% in the referent quartile. Other independent predictors of mortality were ischemic etiology (RR: 2.16 [CI: 1.3-3.5], p = 0.0017), NYHA III/IV class (RR: 2.45 [CI: 1.51-3.97], p = 0.0003), LVEF high-risk subgroup and can more accurately be identified by the CG formula corrected for BSA than the MDRD. Copyright © 2009 Elsevier B.V. All rights reserved.

  6. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  7. Pre-procedural peripheral endothelial function is associated with increased serum creatinine following percutaneous coronary procedure in stable patients with a preserved estimated glomerular filtration rate.

    Science.gov (United States)

    Sumida, Hitoshi; Matsuzawa, Yasushi; Sugiyama, Seigo; Sugamura, Koichi; Nozaki, Toshimitsu; Akiyama, Eiichi; Ohba, Keisuke; Konishi, Masaaki; Matsubara, Junichi; Fujisue, Koichiro; Maeda, Hirofumi; Kurokawa, Hirofumi; Iwashita, Satomi; Ogawa, Hisao; Tsujita, Kenichi

    2017-11-01

    Worsening renal function, indicated by increased serum creatinine (SCr), is a common complication of percutaneous coronary procedures. Risk factors for increased SCr overlap with coronary risk factors involved in endothelial dysfunction. We hypothesized that endothelial dysfunction, measured using the reactive hyperemia peripheral arterial tonometry index (RHI), can predict periprocedure-increased SCr. RHI was assessed before elective coronary procedures in 316 consecutive stable patients with a preserved estimated glomerular filtration rate (eGFR, >60mL/min/1.73m 2 ). SCr was measured before and 2 days after procedures. There was no significant correlation between natural logarithmic transformations of RHI (Ln-RHI) and basal Ln-eGFR. Periprocedure increase in SCr was observed in 148 (47%) patients. The increased SCr group had significantly lower Ln-RHI [0.48 (0.36, 0.62) vs. 0.59 (0.49, 0.76), pfunction by RHI is an effective strategy to assess the patient's risk conditions for worsening renal function after percutaneous coronary procedures. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  8. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients

    OpenAIRE

    Venkatapathy, Ramesh; Govindarajan, Vasupradha; Oza, Nirima; Parameswaran, Sreejith; Pennagaram Dhanasekaran, Balamurali; Prashad, Karthikshree V.

    2014-01-01

    Context. Sampling blood for serum analysis is an invasive procedure. A noninvasive alternative would be beneficial to patients and health care professionals. Aim. To correlate serum and salivary creatinine levels and evaluate the role of saliva as a noninvasive alternative to serum for creatinine estimation in chronic kidney disease patients. Study Design. Case-control study. Methods. Blood and saliva samples were collected from 37 healthy individuals and 105 chronic kidney disease patients...

  9. Serum cystatin C as an earlier predictor of acute kidney injury than serum creatinine in preterm neonates with respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Noha Ahmed Abdelaal

    2017-01-01

    Full Text Available In this study, we aimed to evaluate serum cystatin C (sCysC as an early predictor of acute kidney injury (AKI in preterm neonates with respiratory distress syndrome (RDS. Sixty preterm neonates diagnosed with RDS and 40 healthy controls (28–36 weeks admitted to the neonatal Intensive Care Unit were investigated. AKI was defined on the 3rd day of life (DOL-3 as an increase in serum creatinine (sCr of >0.3 mg/dL from baseline (the lowest previous sCr. sCysC levels were measured on DOL-1, -3 and -7. Of the 60 neonates with RDS, 24 (40% developed AKI. Five patients (79.17% were classified as AKI Network (AKIN-1 and 19 patients (20.83%, as AKIN-2. At DOL-3, the mean sCysC values were significantly higher among neonates with RDS and AKI (1.68 ± 0.37 compared with controls (0.79 ± 0.83 and those with RDS and no AKI (0.85 ± 0.20 (P <0.001. sCysC levels significantly increased among neonates with AKI from DOL-3 to DOL-7 (P = 0.002. The sCr values showed no significant difference between those with RDS with AKI, RDS, and no AKI or control groups at DOL-1 and -3. Only as late as DOL-7, the mean values of sCr were higher among neonates with AKI compared with no AKI and controls (P <0.001. The receiver operating characteristic curves area under the curve was 0.97 for predicting the development of AKI within 72 h (P = 0.001. With the best cutoff value of ≥1.28 mg/L, the sensitivity and specificity of sCysC for detecting AKI within 72 h were 100 and 83.3%, respectively. In conclusion, sCysC is an early marker for AKI in neonates with RDS.

  10. A meta-analysis of genome-wide data from five European isolates reveals an association of COL22A1, SYT1, and GABRR2 with serum creatinine level

    Directory of Open Access Journals (Sweden)

    Oostra Ben A

    2010-03-01

    Full Text Available Abstract Background Serum creatinine (SCR is the most important biomarker for a quick and non-invasive assessment of kidney function in population-based surveys. A substantial proportion of the inter-individual variability in SCR level is explicable by genetic factors. Methods We performed a meta-analysis of genome-wide association studies of SCR undertaken in five population isolates ('discovery cohorts', all of which are part of the European Special Population Network (EUROSPAN project. Genes showing the strongest evidence for an association with SCR (candidate loci were replicated in two additional population-based samples ('replication cohorts'. Results After the discovery meta-analysis, 29 loci were selected for replication. Association between SCR level and polymorphisms in the collagen type XXII alpha 1 (COL22A1 gene, on chromosome 8, and in the synaptotagmin-1 (SYT1 gene, on chromosome 12, were successfully replicated in the replication cohorts (p value = 1.0 × 10-6 and 1.7 × 10-4, respectively. Evidence of association was also found for polymorphisms in a locus including the gamma-aminobutyric acid receptor rho-2 (GABRR2 gene and the ubiquitin-conjugating enzyme E2-J1 (UBE2J1 gene (replication p value = 3.6 × 10-3. Previously reported findings, associating glomerular filtration rate with SNPs in the uromodulin (UMOD gene and in the schroom family member 3 (SCHROOM3 gene were also replicated. Conclusions While confirming earlier results, our study provides new insights in the understanding of the genetic basis of serum creatinine regulatory processes. In particular, the association with the genes SYT1 and GABRR2 corroborate previous findings that highlighted a possible role of the neurotransmitters GABAA receptors in the regulation of the glomerular basement membrane and a possible interaction between GABAAreceptors and synaptotagmin-I at the podocyte level.

  11. Relation between serum creatinine and postoperative results of open-heart surgery.

    Science.gov (United States)

    Ezeldin, Tamer H

    2013-10-01

    To determine the impact of preoperative serum creatinine level in non-dialyzable patients on postoperative morbidity and mortality. This is a prospective study, where serum creatinine was used to give primary assessment on renal function status preoperatively. This study includes 1,033 patients, who underwent coronary artery bypass grafting, or valve(s) operations. The study took place at Al-Hada Military Hospital, Taif, Kingdom of Saudi between May 2008 and January 2012. Data were statistically analyzed using Chi square (x2) test and multivariable logistic regression, to evaluate the postoperative morbidity and mortality risks associated with low serum creatinine levels. Postoperative mortality increased with high serum creatinine level >1.8 mg/dL (pcreatinine level of more than 1.8 mg/dL was associated with increased risk of re-operation for bleeding, postoperative renal failure, prolonged ventilatory support, ICU stay, and total hospital stay. Perioperative serum creatinine is strongly related to post operative morbidity and mortality in open heart surgery. High serum creatinine in non-dialyzable patients can predict the increased morbidity and mortality after cardiac operations.

  12. GFR Prediction From Cystatin C and Creatinine in Children

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Boegsted, Martin

    2012-01-01

    area, and SCr is serum creatinine level. The accuracy and precision of these models were compared with 7 previously published prediction models using random subsampling cross-validation. Local constants and coefficients were calculated for all models. Root mean square error, R2, and percentage...... are still not sufficiently accurate to replace exogenous markers when GFR must be determined with high accuracy....

  13. Critical serum creatinine values in very preterm newborns.

    Directory of Open Access Journals (Sweden)

    Alexandra Bruel

    Full Text Available BACKGROUND: Renal failure in neonates is associated with an increased risk of mortality and morbidity. But critical values are not known. OBJECTIVE: To define critical values for serum creatinine levels by gestational age in preterm infants, as a predictive factor for mortality and morbidity. STUDY DESIGN: This was a retrospective study of all preterm infants born before 33 weeks of gestational age, hospitalized in Nantes University Hospital NICU between 2003 and 2009, with serum creatinine levels measured between postnatal days 3 to 30. Children were retrospectively randomized into either training or validation set. Critical creatinine values were defined within the training set as the 90(th percentile values of highest serum creatinine (HSCr in infants with optimal neurodevelopmental at two years of age. The relationship between these critical creatinine values and neonatal mortality, and non-optimal neural development at two years, was then assessed in the validation set. RESULTS AND CONCLUSION: The analysis involved a total of 1,461 infants (gestational ages of 24-27 weeks (n=322, 28-29 weeks (n=336, and 30-32 weeks (803, and 14,721 creatinine assessments. The critical values determined in the training set (n=485 were 1.6, 1.1 and 1.0 mg/dL for each gestational age group, respectively. In the validation set (n=976, a serum creatinine level above the critical value was significantly associated with neonatal mortality (Odds ratio: 8.55 (95% confidence interval: 4.23-17.28; p<0.01 after adjusting for known renal failure risk factors, and with non-optimal neurodevelopmental outcome at two years (odds ratio: 2.06 (95% confidence interval: 1.26-3.36; p=0.004 before adjustment. Creatinine values greater than 1.6, 1.1 and 1.0 mg/dL respectively at 24-27, 28-29, 30-32 weeks of gestation were associated with mortality before and after adjustment for risk factors, and with non-optimal neurodevelopmental outcome, before adjustment.

  14. GFR prediction from cystatin C and creatinine in children: body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    ) aged 2-14 years (mean 8.8 years). GFR was 14-147 mL/min/1.73m2 (mean 97 mL/min/1.73m2). BCM was estimated using bioimpedance spectroscopy (Xitron Hydra 4200). Log-transformed data on BCM/CysC, serum creatinine (SCr), body-surface-area (BSA), height x BSA/SCr, serum CysC, weight, sex, age, height, serum....... The present equation also had the highest R2 and the narrowest 95% limits of agreement. CONCLUSION: The new equation predicts GFR with higher accuracy than other equations. Endogenous methods are, however, still not accurate enough to replace exogenous markers when GFR must be determined with high accuracy...

  15. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  16. A meta-analysis on diagnostic value of serum cystatin C and creatinine for the evaluation of glomerular filtration function in renal transplant patients.

    Science.gov (United States)

    Pan, Pan; Binjie, Hu; Min, Li; Lipei, Fan; Yanli, Ni; Junwen, Zhou; Xianghua, Shi

    2014-12-01

    This meta-analysis aimed to perform a systematic review on comparing the diagnostic value of serum cystatin C and creatinine for glomerular filtration rate in renal transplant patients. The data was extracted into 2×2 table after the articles were assessed by the tool of QUADAS and heterogeneity analysis. The SROC curve and meta-analysis were performed by MetaDisc1.4. Meta-analysis showed that the serum cystatin C had no heterogeneity (P=0.418, I2=2.2%, DOR=25.03), while creatinine heterogeneity was high (P=0.109, I2=37.5%, DOR=9.11). The values of SEN, SPE and SAUC were calculated as 0.86, 0.70 and 0.9015 for cystatin C, and 0.78, 0.73 and 0.8285 for creatinine individually. This study utilized GFR detection and subgroups analysis by cutoff. The PLR was 6.13 and the NLR was 0.12 for cystatin C, compared to SCr (3.72, 0.32). There was homogeneity among these studies using PENIA testing for cystatin C (χ2=2.61, P=0.4560, I2=0.0%. There were significant correlations among cystatin C , creatinine and glomerular filtration rate (GFR). Cystatin C had more sensitivity but less specificity than creatinine for evaluation of GFR. Cystatin C had strong ability in diagnosing renal function after renal transplant and ruling out diagnostic efficacy.

  17. A comparison of definitions of contrast-induced nephropathy in patients with normal serum creatinine

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Khatami

    2016-01-01

    Full Text Available Contrast-induced nephropathy (CIN is the third leading cause of acute kidney injury in hospitalized patients. The prevalence of CIN is reported to range from 0% to 50%, depending not only on patient condition and the procedure used but also the definition of CIN applied. We aimed to determine the best diagnostic indicator of CIN in patients with normal serum creatinine. This study included 206 patients with normal serum creatinine who underwent coronary angiography/angioplasty. Serum creatinine level and glomerular filtration rate (GFR were measured before and on the second and fifth days after contrast administration. The incidence of CIN based on a 25% increase in serum creatinine was calculated and compared with the incidence based on a 25% decrease in GFR or an increase of at least 0.5 mg/dL in serum creatinine. Of 206 patients, 127 were male (61.7% and 79 were female (38.3%; the mean age was 59.56 ± 10.3 years. The prevalence of CIN was 30% based on a 25% increase in serum creatinine, 23% based on a 25% decrease in GFR (P <0.012 and 3.8% based on a serum creatinine increase of at least 0.5 mg/dL (P <0.0001. The serum creatinine levels remained within the normal range in the majority of patients with CIN based on the different definitions. In patients with normal serum creatinine, the absolute increase in serum creatinine may describe the prevalence of CIN more accurately than the relative increase in serum creatinine or relative decrease in GFR.

  18. Prediction of renal function (GFR) from cystatin C and creatinine in children: Body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    ) aged 2-14 years (mean 8.8 years). GFR was 14-147 mL/min/1.73m2 (mean 97 mL/min/1.73m2). BCM was estimated using bioimpedance spectroscopy (Xitron Hydra 4200). Log-transformed data on BCM/CysC, serum creatinine (SCr), body-surface-area (BSA), height x BSA/SCr, serum CysC, weight, sex, age, height, serum....... The present equation also had the highest R2 and the narrowest 95% limits of agreement. CONCLUSION: The new equation predicts GFR with higher accuracy than other equations. Endogenous methods are, however, still not accurate enough to replace exogenous markers when GFR must be determined with high accuracy...

  19. Choice of Reference Serum Creatinine in Defining AKI

    Science.gov (United States)

    Siew, Edward D.; Matheny, Michael E.

    2015-01-01

    Background/Aims The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. Methods We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating estimation of baseline renal function, using Pubmed and reference back-tracing within known works. Results 1) Prehospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, 2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations 3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, 4) using more specific definitions of AKI (e.g. KIDGO Stage 2 and 3) may help to reduce the effects of misclassification when using surrogate values, and 5) leveraging available clinical data may help refine the estimate of reference creatinine. Conclusions Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the

  20. Body Composition Analysis Allows the Prediction of Urinary Creatinine Excretion and of Renal Function in Chronic Kidney Disease Patients.

    Science.gov (United States)

    Donadio, Carlo

    2017-05-28

    The aim of this study was to predict urinary creatinine excretion (UCr), creatinine clearance (CCr) and the glomerular filtration rate (GFR) from body composition analysis. Body cell mass (BCM) is the compartment which contains muscle mass, which is where creatinine is generated. BCM was measured with body impedance analysis in 165 chronic kidney disease (CKD) adult patients (72 women) with serum creatinine (SCr) 0.6-14.4 mg/dL. The GFR was measured ( 99m Tc-DTPA) and was predicted using the Modification of Diet in Renal Disease (MDRD) formula. The other examined parameters were SCr, 24-h UCr and measured 24-h CCr (mCCr). A strict linear correlation was found between 24-h UCr and BCM ( r = 0.772). Multiple linear regression (MR) indicated that UCr was positively correlated with BCM, body weight and male gender, and negatively correlated with age and SCr. UCr predicted using the MR equation (MR-UCr) was quite similar to 24-h UCr. CCr predicted from MR-UCr and SCr (MR-BCM-CCr) was very similar to mCCr with a high correlation ( r = 0.950), concordance and a low prediction error (8.9 mL/min/1.73 m²). From the relationship between the GFR and the BCM/SCr ratio, we predicted the GFR (BCM GFR). The BCM GFR was very similar to the GFR with a high correlation ( r = 0.906), concordance and a low prediction error (12.4 mL/min/1.73 m²). In CKD patients, UCr, CCr and the GFR can be predicted from body composition analysis.

  1. Inverse association between serum creatinine and mortality in acute kidney injury.

    Science.gov (United States)

    de Souza, Sergio Pinto; Matos, Rodrigo Santos; Barros, Luisa Leite; Rocha, Paulo Novis

    2014-01-01

    Sepsis is a leading precipitant of Acute Kidney Injury (AKI) in intensive care unit (ICU) patients, and is associated with a high mortality rate. We aimed to evaluate the risk factors for dialysis and mortality in a cohort of AKI patients of predominantly septic etiology. Adult patients from an ICU for whom nephrology consultation was requested were included. End-stage chronic renal failure and kidney transplant patients were excluded. 114 patients were followed. Most had sepsis (84%), AKIN stage 3 (69%) and oliguria (62%) at first consultation. Dialysis was performed in 66% and overall mortality was 70%. Median serum creatinine in survivors and non-survivors was 3.95 mg/dl (2.63 - 5.28) and 2.75 mg/dl (1.81 - 3.69), respectively. In the multivariable models, oliguria and serum urea were positively associated with dialysis; otherwise, a lower serum creatinine at first consultation was independently associated with higher mortality. In a cohort of septic AKI, oliguria and serum urea were the main indications for dialysis. We also described an inverse association between serum creatinine and mortality. Potential explanations for this finding include: delay in diagnosis, fluid overload with hemodilution of serum creatinine or poor nutritional status. This finding may also help to explain the low discriminative power of general severity scores - that assign higher risks to higher creatinine levels - in septic AKI patients.

  2. Is Doubling of Serum Creatinine a Valid Clinical 'Hard' Endpoint in Clinical Nephrology Trials?

    NARCIS (Netherlands)

    Lambers Heerspink, H. J.; Perkovic, V.; de Zeeuw, D.

    2011-01-01

    The composite of end stage renal disease (ESRD), doubling of serum creatinine and (renal) death, is a frequently used endpoint in randomized clinical trials in nephrology. Doubling of serum creatinine is a well-accepted part of this endpoint because a doubling of serum creatinine reflects a large

  3. Inverse association between serum creatinine and mortality in acute kidney injury

    Directory of Open Access Journals (Sweden)

    Sergio Pinto de Souza

    2014-12-01

    Full Text Available Introduction: Sepsis is a leading precipitant of Acute Kidney Injury (AKI in intensive care unit (ICU patients, and is associated with a high mortality rate. Objective: We aimed to evaluate the risk factors for dialysis and mortality in a cohort of AKI patients of predominantly septic etiology. Methods: Adult patients from an ICU for whom nephrology consultation was requested were included. End-stage chronic renal failure and kidney transplant patients were excluded. Results: 114 patients were followed. Most had sepsis (84%, AKIN stage 3 (69% and oliguria (62% at first consultation. Dialysis was performed in 66% and overall mortality was 70%. Median serum creatinine in survivors and non-survivors was 3.95 mg/dl (2.63 - 5.28 and 2.75 mg/dl (1.81 - 3.69, respectively. In the multivariable models, oliguria and serum urea were positively associated with dialysis; otherwise, a lower serum creatinine at first consultation was independently associated with higher mortality. Conclusion: In a cohort of septic AKI, oliguria and serum urea were the main indications for dialysis. We also described an inverse association between serum creatinine and mortality. Potential explanations for this finding include: delay in diagnosis, fluid overload with hemodilution of serum creatinine or poor nutritional status. This finding may also help to explain the low discriminative power of general severity scores - that assign higher risks to higher creatinine levels - in septic AKI patients.

  4. Serum creatinine and alkaline phosphatase levels are associated with severe chronic periodontitis.

    Science.gov (United States)

    Caúla, A L; Lira-Junior, R; Tinoco, E M B; Fischer, R G

    2015-12-01

    Periodontitis may alter systemic homeostasis and influence creatinine and alkaline phosphatase levels. Therefore, the aim of this study was to evaluate the relationship between severe chronic periodontitis and serum creatinine and alkaline phosphatase levels. One hundred patients were evaluated, 66 with severe chronic periodontitis (test group) and 34 periodontally healthy controls (control group). Medical, demographic and periodontal parameters were registered. Blood sample was collected after an overnight fast and serum creatinine and alkaline phosphatase levels were determined. There were significant differences between test and control groups in ethnicity, gender and educational level (p creatinine level (p creatinine and alkaline phosphatase levels. Severe chronic periodontitis was associated to lower creatinine and higher alkaline phosphatase levels. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Kidney transplantation from deceased donors with elevated serum creatinine.

    Science.gov (United States)

    Gallinat, Anja; Leerhoff, Sabine; Paul, Andreas; Molmenti, Ernesto P; Schulze, Maren; Witzke, Oliver; Sotiropoulos, Georgios C

    2016-12-01

    Elevated donor serum creatinine has been associated with inferior graft survival in kidney transplantation (KT). The aim of this study was to evaluate the impact of elevated donor serum creatinine on short and long-term outcomes and to determine possible ways to optimize the use of these organs. All kidney transplants from 01-2000 to 12-2012 with donor creatinine ≥ 2 mg/dl were considered. Risk factors for delayed graft function (DGF) were explored with uni- and multivariate regression analyses. Donor and recipient data were analyzed with uni- and multivariate cox proportional hazard analyses. Graft and patient survival were calculated using the Kaplan-Meier method. Seventy-eight patients were considered. Median recipient age and waiting time on dialysis were 53 years and 5.1 years, respectively. After a median follow-up of 6.2 years, 63 patients are alive. 1, 3, and 5-year graft and patient survival rates were 92, 89, and 89 % and 96, 93, and 89 %, respectively. Serum creatinine level at procurement and recipient's dialysis time prior to KT were predictors of DGF in multivariate analysis (p = 0.0164 and p = 0.0101, respectively). Charlson comorbidity score retained statistical significance by multivariate regression analysis for graft survival (p = 0.0321). Recipient age (p = 0.0035) was predictive of patient survival by multivariate analysis. Satisfactory long-term kidney transplant outcomes in the setting of elevated donor serum creatinine ≥2 mg/dl can be achieved when donor creatinine is <3.5 mg/dl, and the recipient has low comorbidities, is under 56 years of age, and remains in dialysis prior to KT for <6.8 years.

  6. The elevated serum urea:creatinine ratio in canine babesiosis in South Africa is not of renal origin.

    Science.gov (United States)

    de Scally, M P; Leisewitz, A L; Lobetti, R G; Thompson, P N

    2006-12-01

    Pigmented serum, usually due to free haemoglobin and/or bilirubin, is a common finding in dogs with babesiosis, resulting in interference with all biochemical tests that rely on photochemistry. This is particularly true of urea and creatinine determinations, complicating the diagnosis of acute renal failure, which is a serious complication of babesiosis. A disproportionately raised serum urea concentration of unknown origin occurs in severely anaemic canine babesiosis patients and gives rise to an increased serum urea:creatinine ratio. The assay for cystatin-C, an excellent measure of glomerular filtration rate, is unaffected by free serum haemoglobin, and due to its different intrinsic origins, is free of influence by the metabolic derangements and organ pathology, other than renal disease, encountered in canine babesiosis. Serum cystatin-C was used to compare the concentrations of serum urea and serum creatinine in dogs with the severely anaemic form of canine babesiosis as well as a canine babesiosis-free reference group. Mean serum urea and mean serum urea:creatinine ratio were significantly elevated in the babesia-infected group relative to the reference population in this study. Mean serum creatinine and mean serum cystatin-C were within the reference ranges. Therefore an elevated urea:creatinine ratio in canine babesiosis in the presence of a normal serum creatinine concentration is considered to be caused by an elevated serum urea concentration and is most likely of non-renal origin. Serum creatinine was therefore as specific a measure of renal function as serum cystatin-C in canine babesiosis in this study. The sensitivity of serum creatinine as a measure of renal function was not established by this study. Serum urea, however, proved to be of little use compared to serum cystatin-C and serum creatinine. Serum urea should therefore not be used to diagnose renal failure in canine babesiosis.

  7. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  8. The Preinterventional Cystatin-Creatinine-Ratio: A Prognostic Marker for Contrast Medium-Induced Acute Kidney Injury and Long-Term All-Cause Mortality.

    Science.gov (United States)

    Lüders, Florian; Meyborg, Matthias; Malyar, Nasser; Reinecke, Holger

    2015-01-01

    Contrast medium-induced acute kidney injury (CI-AKI) is an important iatrogenic complication following the injection of iodinated contrast media. The level of serum creatinine (SCr) is the currently accepted 'gold standard' to diagnose CI-AKI. Cystatin C (CyC) has been detected as a more sensitive marker for renal dysfunction. Both have their limitations. The role of the preinterventional CyC-SCr ratio for evaluating the risk for CI-AKI and long-term all-cause mortality was retrospectively analyzed in the prospective single-center 'Dialysis-versus-Diuresis trial'. CI-AKI was defined and staged according to the Acute Kidney Injury Network classification. Three hundred and seventy-three patients were included (average age 67.4 ± 10.2 years, 16.4% women, 29.2% with diabetes mellitus, mean baseline glomerular filtration rate 56.3 ± 20.2 ml/min/1.73 m(2) [as estimated by Chronic Kidney Disease Epidemiology Collaboration Serum Creatinine Cystatin C equation], 5.1% ejection fraction high significant association between preinterventional CyC-SCr ratio and long-term all-cause mortality (mean follow-up 649 days, hazards ratio 4.096, 95% CI 1.625-10.329, p = 0.003). The preinterventional CyC-SCr ratio is independently associated with CI-AKI and highly significant associated with long-term mortality after heart catheterization. © 2015 S. Karger AG, Basel.

  9. Lower Serum Creatinine Is Associated with Low Bone Mineral Density in Subjects without Overt Nephropathy

    Science.gov (United States)

    Huh, Ji Hye; Choi, Soo In; Lim, Jung Soo; Chung, Choon Hee; Shin, Jang Yel; Lee, Mi Young

    2015-01-01

    Background Low skeletal muscle mass is associated with deterioration of bone mineral density. Because serum creatinine can serve as a marker of muscle mass, we evaluated the relationship between serum creatinine and bone mineral density in an older population with normal renal function. Methods Data from a total of 8,648 participants (4,573 men and 4,075 postmenopausal women) aged 45–95 years with an estimated glomerular filtration rate >60 ml/min/1.73 m2 were analyzed from the Fourth Korea National Health and Nutrition Examination Survey (2008–2010). Bone mineral density (BMD) and appendicular muscle mass (ASM) were measured using dual-energy X-ray absorptiometry. Receiver operating characteristic curve analysis revealed that the cut points of serum creatinine for sarcopenia were below 0.88 mg/dl in men and 0.75 mg/dl in women. Subjects were divided into two groups: low creatinine and upper normal creatinine according to the cut point value of serum creatinine for sarcopenia. Results In partial correlation analysis adjusted for age, serum creatinine was positively associated with both BMD and ASM. Subjects with low serum creatinine were at a higher risk for low BMD (T-score ≤ –1.0) at the femur neck, total hip and lumbar spine in men, and at the total hip and lumbar spine in women after adjustment for confounding factors. Each standard deviation increase in serum creatinine was significantly associated with reduction in the likelihood of low BMD at the total hip and lumbar spine in both sexes (men: odds ratio (OR) = 0.84 [95% CI = 0.74−0.96] at the total hip, OR = 0.8 [95% CI = 0.68−0.96] at the lumbar spine; women: OR = 0.83 [95% CI = 0.73–0.95] at the total hip, OR=0.81 [95% CI = 0.67–0.99] at the lumbar spine). Conclusions Serum creatinine reflected muscle mass, and low serum creatinine was independently associated with low bone mineral density in subjects with normal kidney function. PMID:26207750

  10. Sigma metric analysis for performance of creatinine with fresh frozen serum.

    Science.gov (United States)

    Kang, Fengfeng; Zhang, Chuanbao; Wang, Wei; Wang, Zhiguo

    2016-01-01

    Six sigma provides an objective and quantitative methodology to describe the laboratory testing performance. In this study, we conducted a national trueness verification scheme with fresh frozen serum (FFS) for serum creatinine to evaluate its performance in China. Two different concentration levels of FFS, targeted with reference method, were sent to 98 laboratories in China. Imprecision and bias of the measurement procedure were calculated for each participant to further evaluate the sigma value. Quality goal index (QGI) analysis was used to investigate the reason of unacceptable performance for laboratories with σ high concentration of creatinine had preferable sigma values. For the enzymatic method, 7.0% (5/71) to 45.1% (32/71) of the laboratories need to improve their measurement procedures (σ 1.2). Only 3.1-5.3% of the laboratories should improve both of the precision and trueness. Sigma metric analysis of the serum creatinine assays is disappointing, which was mainly due to the unacceptable analytical bias according to the QGI analysis. Further effort is needed to enhance the trueness of the creatinine measurement.

  11. Predicting the ideal serum creatinine of kidney transplant recipients by a simple formula based on the balance between metabolic demands of recipients and renal mass supply from donors.

    Science.gov (United States)

    Oh, C K; Lee, B M; Kim, H; Kim, S I; Kim, Y S

    2008-09-01

    Serum creatinine (Scr) is the most frequently used test to estimate graft function after kidney transplantation. Our previous study demonstrated that the independent predictors of recipient posttransplantation Scr included the ratio of graft weight to recipient body weight, the ratio of graft weight to recipient body surface area (BSA), and the ratio of graft weight to recipient body mass index (BMI). A prospective analysis about the impact of the balance between metabolic demands and renal supply on posttransplantation Scr of recipients was previously reported. We plotted the scatter graph using the X-axis as the independent predictors of Scr by linear regression and the Y-axis as the recipient Scr. To generate the predictive formula of Scr, we calculated a fit of the line of plotted cases using a linear regression method with 2 regression lines for prediction of the upper and lower 95% confidence intervals. Each line was converted into a predictive formula: Scr = -0.0033* (Graft weight(g)/Recipient BSA(m2))+1.75. Under 95% confidence, the Scr ranges from -0.0033* (Graft weight(g)/Recipient BSA(m2))+1.07 to -0.0033* (Graft weight(g)/Recipient BSA (m2))+2.44. Scr = -0.1049* (Graft weight(g)/Recipient body weight(kg))+1.72, which ranges from -0.1049* (Graft weight(g)/Recipient body weight(kg))+1.06 to -0.1049* (Graft weight(g)/Recipient body weight(kg))+2.37. Scr = -0.0158* (Graft weight(g)/Recipient BMI(kg/m2))+1.56, which ranges from -0.0158* (Graft weight(g)/Recipient BMI(kg/m2))+0.75 to -0.0158* (Graft weight(g)/Recipient BMI(kg/m2))+2.26. Prediction of posttransplantation Scr may be achieved by measuring graft weight as well as recipient weight and height. When recipient Scr is significantly higher than that predicted by the formula, a clinician should suspect an underlying graft injury.

  12. Serum and urinary cystatin C in cats with feline immunodeficiency virus infection and cats with hyperthyroidism.

    Science.gov (United States)

    Ghys, Liesbeth Fe; Paepe, Dominique; Taffin, Elien Rl; Vandermeulen, Eva; Duchateau, Luc; Smets, Pascale My; Delanghe, Joris; Daminet, Sylvie

    2016-08-01

    The objective of this study was to investigate serum cystatin C (sCysC) and urinary cystatin C (uCysC) in cats with hyperthyroidism and cats with feline immunodeficiency virus (FIV). Thirty cats with FIV, 26 hyperthyroid cats and 28 healthy cats were included. sCysC and uCysC:creatinine (uCysC/uCr) ratio were measured with a human particle-enhanced nephelometric immunoassay, previously validated for feline CysC measurement. Routine renal variables (serum creatinine [sCr], urine specific gravity, urinary protein:creatinine ratio [UPC]) were also measured in the three groups. Cats with hyperthyroidism had significantly higher sCysC and higher uCysC/uCr ratio, lower sCr and a higher UPC than healthy cats. Cats with FIV infection did not show a significantly higher sCysC concentration but had a significantly higher sCr and UPC than healthy cats. uCysC could be detected in only four of them. This study demonstrated that sCysC is increased in cats with hyperthyroidism, in contrast with sCr, but not in cats with FIV. Many hyperthyroid cats, but only four cats with FIV, had an elevated uCysC/uCr ratio. Further studies may reveal if uCysC might be a valuable marker for tubular dysfunction in cats. © The Author(s) 2015.

  13. Choice of Reference Serum Creatinine in Defining Acute Kidney Injury.

    Science.gov (United States)

    Siew, Edward D; Matheny, Michael E

    2015-01-01

    The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating the estimation of baseline renal function, using PubMed and reference back-tracing within known works. (1) Pre-hospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, (2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations, (3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, (4) using more specific definitions of AKI (e.g., KIDGO stages 2 and 3) may help to reduce the effects of misclassification when using surrogate values and (5) leveraging available clinical data may help refine the estimate of reference creatinine. Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine

  14. [New topics regarding equations for GFR estimation based on serum creatinine and cystatin C].

    Science.gov (United States)

    Horio, Masaru

    2014-02-01

    Japanese GFR equations and CKD-EPI equations based on standardized serum creatinine and standardized cystatin C are recommended in recent Japanese CKD guides and KDIGO guidelines for CKD management, respectively. CKD-EPIcreat overestimates GFR in Japanese subjects, probably due to the difference in muscle mass between Japanese and Caucasians. Unlike CKD-EPIcreat, CKD-EPIcys performs well in Japanese subjects, indicating the advantages of using cystatin C as a GFR marker. KDIGO guidelines suggest measuring eGFRcys in adults with eGFRcreat of 45-59 ml/min/1.73 m2 who do not have markers of kidney damage if confirmation of CKD is required. Creatinine is excreted by glomerular filtration, but also secreted by the tubules. Alteration of the tubular secretion of creatinine may influence the performance of GFR equations based on serum creatinine. Multivariate analysis showed that GFR and serum albumin levels were independent parameters affecting the fractional excretion of creatinine (FE-Cr). Alteration of FE-Cr according to the serum albumin levels may be one of the reasons for the bias of GFR equations based on serum creatinine. Low GFR is a risk factor for all-cause and cardiovascular mortality in a general population. However, the relationship between eGFR and the hazard risk of events is different depending on whether cystatin C or creatinine is used to calculate eGFR. The association between eGFRcys and the hazard risk is much stronger compared with eGFRcreat. Cystatin C may be a useful alternative to creatinine for detecting a high risk of complications in a general population and subjects with CKD.

  15. Creatinine generation from kinetic modeling with or without postdialysis serum creatinine measurement: results from the HEMO study.

    Science.gov (United States)

    Daugirdas, John T; Depner, Thomas A

    2017-11-01

    A convenient method to estimate the creatinine generation rate and measures of creatinine clearance in hemodialysis patients using formal kinetic modeling and standard pre- and postdialysis blood samples has not been described. We used data from 366 dialysis sessions characterized during follow-up month 4 of the HEMO study, during which cross-dialyzer clearances for both urea and creatinine were available. Blood samples taken at 1 h into dialysis and 30 min and 60 min after dialysis were used to determine how well a two-pool kinetic model could predict creatinine concentrations and other kinetic parameters, including the creatinine generation rate. An extrarenal creatinine clearance of 0.038 l/kg/24 h was included in the model. Diffusive cross-dialyzer clearances of urea [230 (SD 37 mL/min] correlated well (R2 = 0.78) with creatinine clearances [164 (SD 30) mL/min]. When the effective diffusion volume flow rate was set at 0.791 times the blood flow rate for the cross-dialyzer clearance measurements at 1 h into dialysis, the mean calculated volume of creatinine distribution averaged 29.6 (SD 7.2) L], compared with 31.6 (SD 7.0) L for urea (P creatinine generation rate [1183 (SD 463) mg/day] averaged 100.1 % (SD 29; median 99.3) of that predicted in nondialysis patients by an anthropometric equation. A simplified method for modeling the creatinine generation rate using the urea distribution volume and urea dialyzer clearance without use of the postdialysis serum creatinine measurement gave results for creatinine generation rate [1187 (SD 475) mg/day; that closely matched the value calculated using the formally modeled value, R2 = 0.971]. Our analysis confirms previous findings of similar distribution volumes for creatinine and urea. After taking extra-renal clearance into consideration, the creatinine generation rate in dialysis patients is similar to that in nondialysis patients. A simplified method based on urea clearance

  16. Can salivary creatinine and urea levels be used to diagnose chronic kidney disease in children as accurately as serum creatinine and urea levels? A case-control study.

    Science.gov (United States)

    Renda, Rahime

    2017-11-01

    Children with chronic kidney disease (CKD) develop many metabolic changes in blood that often necessitate frequent biochemical analysis. Serum analysis is an invasive and painful procedure. It would be highly beneficial if a noninvasive alternative process to serum analysis in children were identified. Saliva can be collected noninvasively, repeatedly, and without the use of healthcare personnel. The aims of this study were to compare serum and salivary urea and creatinine levels in children with CKD and healthy controls, and to determine if salivary creatinine and urea levels can be used to diagnose CKD in children as accurately as serum creatinine and urea levels. This case-control study included 35 children with CKD and 28 healthy children as controls. Saliva and blood samples were collected for measurement of urea and creatinine levels. The urea and creatinine levels in serum and saliva in the CKD and control groups were compared using the independent samples Mann-Whitney U test. Correlations between the serum and salivary urea and creatinine levels were determined using Pearson's correlation coefficient. Receiver operating characteristic analysis was used to assess the diagnostic performance of salivary creatinine and cutoff values were identified. In the CKD group, the mean salivary creatinine level was 0.45 mg/dL and the mean salivary urea level was 0.11 mg/dL, versus 28.83 mg/dL and 21.78 mg/dL, respectively, in the control group. Stage 4 and 5 CKD patients had a mean salivary urea level of 31.35 mg/dL, as compared to 17.78 mg/dL in the control group. Serum urea and creatinine, and salivary creatinine were significantly higher in the CKD patients (regardless of disease stage) than in the controls (p creatinine. The area under the curve for salivary creatinine was 0.805. The cutoff value for salivary creatinine was 0.125 mg/dL, with a sensitivity of 82.9% and specificity of 78.6%. Based on the positive correlation between the serum and saliva

  17. Serum Creatinine Versus Plasma Methotrexate Levels to Predict Toxicities in Children Receiving High-dose Methotrexate.

    Science.gov (United States)

    Tiwari, Priya; Thomas, M K; Pathania, Subha; Dhawan, Deepa; Gupta, Y K; Vishnubhatla, Sreenivas; Bakhshi, Sameer

    2015-01-01

    Facilities for measuring methotrexate (MTX) levels are not available everywhere, potentially limiting administration of high-dose methotrexate (HDMTX). We hypothesized that serum creatinine alteration after HDMTX administration predicts MTX clearance. Overall, 122 cycles in 50 patients of non-Hodgkin lymphoma or acute lymphoblastic leukemia aged ≤18 years receiving HDMTX were enrolled prospectively. Plasma MTX levels were measured at 12, 24, 36, 48, 60, and 72 hours; serum creatinine was measured at baseline, 24, 48, and 72 hours. Correlation of plasma MTX levels with creatinine levels and changes in creatinine from baseline (Δ creatinine) were evaluated. Plasma MTX levels at 72 hours showed positive correlation with serum creatinine at 48 hours (P = .011) and 72 hours (P = .013) as also Δ creatinine at 48 hours (P = .042) and 72 hours (P = .045). However, cut-off value of either creatinine or Δ creatinine could not be established to reliably predict delayed MTX clearance. Greater than 50% Δ creatinine at 48 and 72 hours significantly predicted grade 3/4 leucopenia (P = .036 and P = .001, respectively) and thrombocytopenia (P = .012 and P = .009, respectively) but not mucositis (P = .827 and P = .910, respectively). Delayed MTX elimination did not predict any grade 3/4 toxicity. In spite of demonstration of significant correlation between serum creatinine and Δ creatinine with plasma MTX levels at 72 hours, cut-off value of either variable to predict MTX delay could not be established. Thus, either of these cannot be used as a surrogate for plasma MTX estimation. Interestingly, Δ creatinine effectively predicted hematological toxicities, which were not predicted by delayed MTX clearance.

  18. Serum urea and creatinine levels in Nigerian human malaria patients

    African Journals Online (AJOL)

    Serum urea and creatinine levels were determined in malaria patients infected with P. falciparum. Serum urea levels decreased significantly (P<0.05) in both mild (4.10 ±1.10 mmol/L) and moderate (4.40 ±1.40 mmol/L) parasitaemia when compared to control subjects (5.50 ±1.40 mmol/L). On the other hand, serum ...

  19. Trends in the levels of urine and serum creatinine: data from NHANES 2001-2014.

    Science.gov (United States)

    Jain, Ram B

    2017-04-01

    Data from the National Health and Nutrition Examination Survey were used to study trends for urine and serum creatinine over 2001-2014 for those aged ≥20 years. In the absence of chronic kidney disease, levels of urine creatinine decreased for the total population, for those aged 20-29, 50-59, and ≥70 years, for males, and for Mexican Americans and other race/ethnicities. Levels of serum cotinine also exhibited a decreasing trend over 2001-2014 for the total population, for those aged 20-29 and 40-49 years, for females, and for non-Hispanic whites and Mexican Americans. In general, levels of serum creatinine and urine creatinine were positively correlated for chronic kidney disease stages 1-3 and negatively correlated for chronic kidney disease stages 4 and 5.

  20. Differences in urine cadmium associations with kidney outcomes based on serum creatinine and cystatin C

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Kim, Nam-Soo; Lee, Byung-Kook; Parsons, Patrick J.; Spector, June; Fadrowski, Jeffrey; Jaar, Bernard G.; Steuerwald, Amy J.; Todd, Andrew C.

    2011-01-01

    Cadmium is a well-known nephrotoxicant; chronic exposure increases risk for chronic kidney disease. Recently, however, associations between urine cadmium and higher creatinine-based estimated glomerular filtration rate (eGFR) have been reported. Analyses utilizing alternate biomarkers of kidney function allow evaluation of potential mechanisms for these observations. We compared associations of urine cadmium with kidney function measures based on serum cystatin C to those with serum creatinine in 712 lead workers. Mean (standard deviation) molybdenum-corrected urine cadmium, Modification of Diet in Renal Disease (MDRD) eGFR and multi-variable cystatin C eGFR were 1.02 (0.65) μg/g creatinine, and 97.4 (19.2) and 112.0 (17.7) mL/min/1.73 m 2 , respectively. The eGFR measures were moderately correlated (r s =0.5; p 2 ; 95% confidence interval=1.6, 6.6). Urine creatinine was associated with serum creatinine-based but not cystatin-C-based eGFRs. These results support a biomarker-specific, rather than a kidney function, effect underlying the associations observed between higher urine cadmium and creatinine-based kidney function measures. Given the routine use of serum and urine creatinine in kidney and biomarker research, additional research to elucidate the mechanism(s) for these associations is essential.

  1. Back to Basics: Is There a Good Reason to Not Systematically Measure Urine Creatinine in Acute Kidney Injury Monitoring?

    Science.gov (United States)

    Maciel, Alexandre Toledo

    2016-01-01

    Regardless of the recent advancements in the understanding of the pathophysiology of acute kidney injury (AKI), its diagnosis remains fundamentally dependent on the serum creatinine (sCr) level and urine output (UO), both of which are considered late markers of AKI, offering only a vague idea of the actual creatinine clearance (CrCl). Although not ideal, CrCl is still the most common alternative of the glomerular filtration rate (GFR) in clinical practice. It is generally accepted that early diagnosis of AKI must reveal kidney impairment before sCr increases. Much effort has been made to find tubular and glomerular markers of injury which increase (in blood and/or in urine) before the 'official' diagnosis of AKI. Most of these markers are expensive and not widely available, especially in developing countries. Urine creatinine (CrU), the major link between sCr and UO, has been systematically ignored and clinicians are usually unaware of its value. The reasons for this are unclear, but it may be related to the lack of a reference range, dependence of its concentration value on the urine flow (which in turn is only adequately assessed with an indwelling urinary catheter) and the clinical unavailability of its counterbalance part - creatinine production. Changes in urine tend to precede changes in blood in the course of AKI development and recovery. Hence, it is important to bear in mind that changes in sCr signal renal dysfunction with a significant delay. The search for a more dynamic, 'real-time' but pragmatic assessment of renal function, especially in patients at risk of abrupt decrease in GFR is certainly one of the most relevant focus of research in the field of AKI monitoring. Systematic CrU assessment may be highly relevant in this case. © 2016 S. Karger AG, Basel.

  2. Changes in Serum Proteins and Creatinine levels in HIV Infected ...

    African Journals Online (AJOL)

    This study examined the level of total serum proteins and globulins in HIV infected Nigerians. 64 patients with HIV infection and 10 apparently healthy subjects were recruited from 3 hospitals in Lagos Metropolis. They were examined for the presence of TB and malaria. Serum total protein, albumin and creatinine levels ...

  3. Evaluation of Serum Cystatin C compared with Creatinine: A study in patients with Pre-eclampsia

    Directory of Open Access Journals (Sweden)

    Salma Malik Mmordas

    2015-11-01

    Full Text Available This is cross sectional study aim to evaluate of serum Cystatin C and Creatinine level among pre-clampsia patients. Hundred subjects were evaluate in this study, 50 preclampsia patients as cases and 50 healthy apparently as control groups. Serum Cystatin C and Creatinine were measuring using MISP-i2, Mindray respectively. In assessment of renal function and compare with creatin in women which diagnostic   preeclampsia.  Result showed there was significant increase in mean concentration of Cystatin C in case versus control groups with P-value 0.000, insignificant different in Creatinine level when compare case group with control group with P-value 0.706. The study conclude that serum Cystatin C is higher in preclampsia patients while Creatinine show insignificant different as serum Cystatin C as marker for glomerular filtration, may be useful as marker for renal disease in preclampsia.  

  4. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    Energy Technology Data Exchange (ETDEWEB)

    Erden, Ayse, E-mail: ayse.erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Sahin, Burcu Savran, E-mail: bsavrans@hotmail.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Orgodol, Horolsuren, E-mail: hoogii99@yahoo.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Erden, Ilhan, E-mail: erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Biyikli, Zeynep, E-mail: zeynep.biyikli@gmail.com [Ankara University, School of Medicine, Department of Biostatistics, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey)

    2011-11-15

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  5. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    International Nuclear Information System (INIS)

    Erden, Ayse; Sahin, Burcu Savran; Orgodol, Horolsuren; Erden, Ilhan; Biyikli, Zeynep

    2011-01-01

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  6. GFR, serum creatinine and 24-hour urine protein in evaluating renal function of patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Chi Xiaohua; Li Guiping; Liu Feng; Wang Bing; Du Li; Deng Zhifang; Li Wei

    2013-01-01

    Background: Diabetes nephropathy is a common complication of diabetes mellitus patients. Early detection of renal impairment can improve the quality of life of patients. Purpose: The value of total GFR, serum creatinine, 24-hour urine protein excretion in diabetes mellitus patients with renal impairment were evaluated. Methods: A retrospective analysis of 147 patients with diabetes undergoing routine renal dynamic imaging was undertaken. The cases were divided into three groups according to the illness duration: group I of not more than five years, group 2 of five to ten years, Gr.3: more than ten years. The 22 renal transplant donors were selected as the normal control group, The total GFR, serum creatinine and 24-hour urinary protein excretion of all patients were measured before the treatments, and the data were statistically analyzed. Results: There was no significant differences in renal function between the two kidneys of in the diabetes mellitus patients (P=0.536). Serum creatinine and total GFR had significant correlation (R 2 =0.762), but no significant relationship between the 24-hour urine protein and the total GFR or serum creatinine. In the early and middle times of renal function impairment, the total GFR and serum creatinine have significant difference in different time periods (P<0.05). During the mid-late times of renal function impairment, total GFR and serum creatinine have no statistically significant differences (P value is 0.781, 0.297). 24-hour urine protein quality had no statistical differences in each stage. However: the total GFR is more sensitive than the serum creatinine in evaluation of early impairing of renal function. Conclusions: There is significant correlation between serum creatinine and total GFR. Both of them can reflect the degree of diabetic renal injury, but the total GFR is more sensitive than serum creatinine in early degree. 24-hour urine protein quantitative can not evaluate the degree of impaired renal function alone

  7. Monodisperse, molecularly imprinted polymers for creatinine by modified precipitation polymerization and their applications to creatinine assays for human serum and urine.

    Science.gov (United States)

    Miura, Chitose; Funaya, Noriko; Matsunaga, Hisami; Haginaka, Jun

    2013-11-01

    Molecularly imprinted polymers (MIPs) for creatinine were prepared by modified precipitation polymerization using methacrylic acid as a functional monomer and divinylbenzene as a crosslinker. The prepared MIPs were monodispersed with a narrow particle size distribution. Binding experiments and Scatchard analyses revealed that two classes of binding sites, high- and low-affinity sites, were formed on the MIPs. The retention and molecular-recognition properties of the MIPs were evaluated by hydrophilic interaction chromatography using a mixture of ammonium acetate buffer and acetonitrile as a mobile phase. With an increase of acetonitrile content, the retention factor of creatinine was increased on the MIP. In addition to shape recognition, hydrophilic interactions seemed to enhance the recognition of creatinine on the MIP. The MIPs' molecular-recognition ability was specific for creatinine; the structurally related compounds such as hydantoin, 1-methylhydantoin, 2-pyrrolidone, N-hydroxysuccinimide and creatine were not recognized. Furthermore, the creatinine concentrations in human serum and urine were successfully determined by direct injection of the deproteinized serum and diluted urine samples onto the MIP. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. The relative role of serum albumin and urinary creatinine as ...

    African Journals Online (AJOL)

    Their weight, Body mass index, serum albumin and 24-hour urinary creatinine were determined before treatment, at the end of the 1st, 2nd, 4th and 6th month of treatment. Using ANOVA, the mean values of the weight, BIM and serum albumin were analysed with further analysis paired student T- test of the pre-treatment ...

  9. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  10. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  11. Timely Diagnosis of Acute Kidney Injury Using Kinetic eGFR and the Creatinine Excretion to Production Ratio, E/eG - Creatinine Can Be Useful!

    Science.gov (United States)

    Endre, Zoltán H; Pianta, Timothy J; Pickering, John W

    2016-01-01

    Post transplant repeated measurements of urine volume and serum creatinine (sCr) are used to assess kidney function. Under non-steady state conditions, repeated measurement of sCr allows calculation of the kinetic estimated GFR (KeGFR). Additional measurement of urinary creatinine allows the calculation of the creatinine excretion to (estimated) production ratio (E/eG). We hypothesized that post-transplant KeGFR and E/eG would predict delayed graft function (DGF), as early as 4 h and outperform a validated clinical model at 12 h. This was a retrospective analysis of prospectively acquired data in a study of 56 recipients of deceased-donor kidney transplant. We assessed predictive performance with the area under the receiver operator characteristic curve (AUC) and the added value to a clinical model with integrated discrimination improvement analysis. At 4 h, the AUC for E/eG was 0.87 (95% CI 0.77-0.96) and for KeGFR 0.69 (95% CI 0.56-0.83). Both E/eG and KeGFR improved the risk prediction of a clinical model for DGF by 32 and 18%, and for non-DGF by 17 and 10%, respectively. While E/eG had better predictive performance of DGF than KeGFR, KeGFR might also facilitate perioperative management including drug dosing after kidney transplantation. Together these measurements may facilitate the possibility of conducting trials of early intervention to ameliorate the adverse effects of ischaemia-reperfusion injury on long-term DGF. © 2016 S. Karger AG, Basel.

  12. Imatinib Increases Serum Creatinine by Inhibiting Its Tubular Secretion in a Reversible Fashion in Chronic Myeloid Leukemia.

    Science.gov (United States)

    Vidal-Petiot, Emmanuelle; Rea, Delphine; Serrano, Fidéline; Stehlé, Thomas; Gardin, Claude; Rousselot, Philippe; Peraldi, Marie-Noëlle; Flamant, Martin

    2016-03-01

    Monitoring renal function is important in imatinib-treated patients with chronic myeloid leukemia because serum creatinine may increase during the course of therapy. The mechanism of this increase and its reversibility on treatment cessation have never been investigated. We retrospectively analyzed data from imatinib-treated patients explored in our renal physiology unit with measurement of glomerular filtration rate (urinary clearance of (51)CrEDTA) and of urinary clearance and tubular secretion of creatinine. Results were compared with those of controls matched for measured glomerular filtration rate, age, gender, and ethnicity. We also analyzed variations of serum creatinine before and during imatinib cessation and after imatinib resumption in patients enrolled in imatinib discontinuation studies. In 4 imatinib-treated patients who underwent thorough renal exploration, the part of creatinine clearance due to tubular secretion was negligible (2.4, 3.1, -1.3, and 2.8 mL/min) and significantly lower than that measured in their respective controls (17.7 ± 5.6, 43.0 ± 18.0, 23.1 ± 6.7, and 18.6 ± 5.6 mL/min, P creatinine tubular secretion (20.3 vs. 17.9 ± 5.2 mL/min in the control population, P = .2). In 15 patients of imatinib discontinuation studies, a median decrease in serum creatinine of 17.9% was observed after imatinib cessation. Resumption of treatment in 6 patients led to a median increase in serum creatinine of 18.8%. Imatinib completely blunts tubular secretion of creatinine, a previously unreported pharmacologic property. This inhibition increases serum creatinine independently of any glomerular dysfunction and is fully reversible on imatinib cessation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. How the use of creatine supplements can elevate serum creatinine in the absence of underlying kidney pathology

    Science.gov (United States)

    Williamson, Lydia; New, David

    2014-01-01

    Serum creatinine is a widely used marker in the assessment of renal function. Elevated creatinine levels suggest kidney dysfunction, prompting the need for further investigation. This report describes a case in which the consumption of the bodybuilding supplement creatine ethyl ester resulted in raised serum creatinine in the absence of true underlying kidney pathology. The abnormalities reversed after discontinuation of the supplement. A case of pseudo renal failure was recognised and kidney function was concluded to be normal. This report aims to address the mechanisms by which the ingestion of creatine ethyl ester can mimic the blood results expected in advanced renal failure, and confronts the problems faced when relying on serum creatinine as a diagnostic tool. PMID:25239988

  14. Low antioxidant status of serum bilirubin, uric acid, albumin and creatinine in patients with myasthenia gravis.

    Science.gov (United States)

    Yang, Dehao; Su, Zhongqian; Wu, Shengjie; Bi, Yong; Li, Xiang; Li, Jia; Lou, Kangliang; Zhang, Hongyu; Zhang, Xu

    2016-12-01

    Oxidative stress and low antioxidant status play a major role in the pathogenesis of inflammatory and autoimmune diseases. Myasthenia gravis (MG) is an autoimmune condition targeting the neuromuscular junction, and its antioxidant status is still controversial. Our study aimed to investigate the correlation between the clinical characteristics of MG and the serum antioxidant status of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine. We measured serum antioxidant molecule levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine in 380 individuals, including 166 MG and 214 healthy controls. We found that MG patients had significantly lower serum levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine than healthy controls, whether male or female. Moreover, it was also shown in our study that uric acid, albumin and creatinine levels in patients with MG were correlated with disease activity and classifications performed by the Myasthenia Gravis Foundation of America. Our findings demonstrated that serum levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine were reduced in patients with MG. This suggested an active oxidative process in MG patients who had low antioxidant status.

  15. Comparison between a serum creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.

    Science.gov (United States)

    Karimzadeh, Iman; Khalili, Hossein

    2016-06-06

    Serum cystatin C (Cys C) has a number of advantages over serum creatinine in the evaluation of kidney function. Apart from Cys C level itself, several formulas have also been introduced in different clinical settings for the estimation of glomerular filtration rate (GFR) based upon serum Cys C level. The aim of the present study was to compare a serum Cys C-based equation with Cockcroft-Gault serum creatinine-based formula, both used in the calculation of GFR, in patients receiving amphotericin B. Fifty four adult patients with no history of acute or chronic kidney injury having been planned to receive conventional amphotericin B for an anticipated duration of at least 1 week for any indication were recruited. At three time points during amphotericin B treatment, including days 0, 7, and 14, serum cystatin C as well as creatinine levels were measured. GFR at the above time points was estimated by both creatinine (Cockcroft-Gault) and serum Cys C based equations. There was significant correlation between creatinine-based and Cys C-based GFR values at days 0 (R = 0.606, P = 0.001) and 7 (R = 0.714, P creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.

  16. Serum creatinine is associated with the prevalence but not disease progression of multiple system atrophy in Chinese population.

    Science.gov (United States)

    Cao, Bei; Guo, XiaoYan; Chen, Ke; Song, Wei; Huang, Rui; Wei, QianQian; Zhao, Bi; Shang, Hui-Fang

    2016-03-01

    Oxidative stress is involved in the pathogenesis of multiple system atrophy (MSA). Creatine, which is converted to creatinine, has an anti-oxidative effect. Our aim is to clarify the correlations between creatinine and the occurrence as well as the progression of MSA. A total of 115 patients with probable MSA and 115 age- and gender-matched healthy controls were included in the study. The serum creatinine level of all patients and controls were evaluated and compared. The mean age of MSA patients was 58.18 ± 8.67 years and the mean disease duration was 2.85 ± 1.71 years. The creatinine level of MSA patients was significantly lower than that of healthy controls (P creatinine quartiles compared with the lowest creatinine quartiles. In a gender-specific analysis, patients with the highest quartiles and second quartiles of creatinine level had decreased occurrence than patients with the lowest quartile in females, but not in males. The serum level of creatinine was not found correlated with the mean rate of annualised changes, neither with other independent factors, such as age, body mass index (BMI), sex, Unified MSA Rating Scale (UMSARS) scores and disease duration at the initial visit in patients with MSA. High level of serum creatinine may be associated with a low occurrence of MSA in Chinese population, especially in female. However, serum creatinine does not deteriorate or ameliorate the progression of MSA.

  17. A study of the prevalence of significant increases in serum creatinine following angiotension-converting enzyme inhibitor administration.

    Science.gov (United States)

    Thorp, M L; Ditmer, D G; Nash, M K; Wise, R; Jaderholm, P L; Smith, J D; Chan, W

    2005-05-01

    Angiontension-converting enzyme inhibitors (ACEIs) are beneficial in the treatment of diabetic and nondiabetic kidney disease, coronary artery disease and congestive heart failure. One adverse effect of ACEIs use is a rise in serum creatinine and potential renal failure. This paper attempts to quantify this risk and assess the need for pre- and post-ACEI serum creatinine measurements. A computerized search of Kaiser Permanente Northwest's electronic medical record was conducted to find patients over the age of 40 years taking lisinopril between July 1, 2000 and June 30, 2002. Patient demographic information and presence in diabetes and coronary artery disease registries was collected. A subsequent search for pre- and postlisinopril serum creatinine levels within 6 months of initial lisinopril prescription was conducted. Patients with prelisinopril creatinine 2.5 mg/dl underwent chart review to discern adverse events associated with the rise in serum creatinine. A total of 18,977 patients were prescribed lisinopril between July 1, 2000 and June 30, 2002. In all 13 166 patients had a pre- and postlisinopril creatinine checked. In all, 31 patients had a rise in creatinine from 2.5 mg/dl (0.2%). Possible contributors to rise in creatinine included congestive heart failure, dehydration and infection. No patients developed end-stage renal disease, although three died. In conclusion, end-stage renal disease is an unlikely outcome among patients prescribed lisinopril and is most likely associated with other events.

  18. Contribution of the organic anion transporter OAT2 to the renal active tubular secretion of creatinine and mechanism for serum creatinine elevations caused by cobicistat.

    Science.gov (United States)

    Lepist, Eve-Irene; Zhang, Xuexiang; Hao, Jia; Huang, Jane; Kosaka, Alan; Birkus, Gabriel; Murray, Bernard P; Bannister, Roy; Cihlar, Tomas; Huang, Yong; Ray, Adrian S

    2014-08-01

    Many xenobiotics including the pharmacoenhancer cobicistat increase serum creatinine by inhibiting its renal active tubular secretion without affecting the glomerular filtration rate. This study aimed to define the transporters involved in creatinine secretion, applying that knowledge to establish the mechanism for xenobiotic-induced effects. The basolateral uptake transporters organic anion transporter OAT2 and organic cation transporters OCT2 and OCT3 were found to transport creatinine. At physiologic creatinine concentrations, the specific activity of OAT2 transport was over twofold higher than OCT2 or OCT3, establishing OAT2 as a likely relevant creatinine transporter and further challenging the traditional view that creatinine is solely transported by a cationic pathway. The apical multidrug and toxin extrusion transporters MATE1 and MATE2-K demonstrated low-affinity and high-capacity transport. All drugs known to affect creatinine inhibited OCT2 and MATE1. Similar to cimetidine and ritonavir, cobicistat had the greatest effect on MATE1 with a 50% inhibition constant of 0.99 μM for creatinine transport. Trimethoprim potently inhibited MATE2-K, whereas dolutegravir preferentially inhibited OCT2. Cimetidine was unique, inhibiting all transporters that interact with creatinine. Thus, the clinical observation of elevated serum creatinine in patients taking cobicistat is likely a result of OCT2 transport, facilitating intracellular accumulation, and MATE1 inhibition.

  19. Contribution of the organic anion transporter OAT2 to the renal active tubular secretion of creatinine and mechanism for serum creatinine elevations caused by cobicistat

    Science.gov (United States)

    Lepist, Eve-Irene; Zhang, Xuexiang; Hao, Jia; Huang, Jane; Kosaka, Alan; Birkus, Gabriel; Murray, Bernard P; Bannister, Roy; Cihlar, Tomas; Huang, Yong; Ray, Adrian S

    2014-01-01

    Many xenobiotics including the pharmacoenhancer cobicistat increase serum creatinine by inhibiting its renal active tubular secretion without affecting the glomerular filtration rate. This study aimed to define the transporters involved in creatinine secretion, applying that knowledge to establish the mechanism for xenobiotic-induced effects. The basolateral uptake transporters organic anion transporter OAT2 and organic cation transporters OCT2 and OCT3 were found to transport creatinine. At physiologic creatinine concentrations, the specific activity of OAT2 transport was over twofold higher than OCT2 or OCT3, establishing OAT2 as a likely relevant creatinine transporter and further challenging the traditional view that creatinine is solely transported by a cationic pathway. The apical multidrug and toxin extrusion transporters MATE1 and MATE2-K demonstrated low-affinity and high-capacity transport. All drugs known to affect creatinine inhibited OCT2 and MATE1. Similar to cimetidine and ritonavir, cobicistat had the greatest effect on MATE1 with a 50% inhibition constant of 0.99 μM for creatinine transport. Trimethoprim potently inhibited MATE2-K, whereas dolutegravir preferentially inhibited OCT2. Cimetidine was unique, inhibiting all transporters that interact with creatinine. Thus, the clinical observation of elevated serum creatinine in patients taking cobicistat is likely a result of OCT2 transport, facilitating intracellular accumulation, and MATE1 inhibition. PMID:24646860

  20. The role of the uncertainty of measurement of serum creatinine concentrations in the diagnosis of acute kidney injury.

    Science.gov (United States)

    Kin Tekce, Buket; Tekce, Hikmet; Aktas, Gulali; Uyeturk, Ugur

    2016-01-01

    Uncertainty of measurement is the numeric expression of the errors associated with all measurements taken in clinical laboratories. Serum creatinine concentration is the most common diagnostic marker for acute kidney injury. The goal of this study was to determine the effect of the uncertainty of measurement of serum creatinine concentrations on the diagnosis of acute kidney injury. We calculated the uncertainty of measurement of serum creatinine according to the Nordtest Guide. Retrospectively, we identified 289 patients who were evaluated for acute kidney injury. Of the total patient pool, 233 were diagnosed with acute kidney injury using the AKIN classification scheme and then were compared using statistical analysis. We determined nine probabilities of the uncertainty of measurement of serum creatinine concentrations. There was a statistically significant difference in the number of patients diagnosed with acute kidney injury when uncertainty of measurement was taken into consideration (first probability compared to the fifth p = 0.023 and first probability compared to the ninth p = 0.012). We found that the uncertainty of measurement for serum creatinine concentrations was an important factor for correctly diagnosing acute kidney injury. In addition, based on the AKIN classification scheme, minimizing the total allowable error levels for serum creatinine concentrations is necessary for the accurate diagnosis of acute kidney injury by clinicians.

  1. Evaluation of Short-Term Changes in Serum Creatinine Level as a Meaningful End Point in Randomized Clinical Trials.

    Science.gov (United States)

    Coca, Steven G; Zabetian, Azadeh; Ferket, Bart S; Zhou, Jing; Testani, Jeffrey M; Garg, Amit X; Parikh, Chirag R

    2016-08-01

    Observational studies have shown that acute change in kidney function (specifically, AKI) is a strong risk factor for poor outcomes. Thus, the outcome of acute change in serum creatinine level, regardless of underlying biology or etiology, is frequently used in clinical trials as both efficacy and safety end points. We performed a meta-analysis of clinical trials to quantify the relationship between positive or negative short-term effects of interventions on change in serum creatinine level and more meaningful clinical outcomes. After a thorough literature search, we included 14 randomized trials of interventions that altered risk for an acute increase in serum creatinine level and had reported between-group differences in CKD and/or mortality rate ≥3 months after randomization. Seven trials assessed interventions that, compared with placebo, increased risk of acute elevation in serum creatinine level (pooled relative risk, 1.52; 95% confidence interval, 1.22 to 1.89), and seven trials assessed interventions that, compared with placebo, reduced risk of acute elevation in serum creatinine level (pooled relative risk, 0.57; 95% confidence interval, 0.44 to 0.74). However, pooled risks for CKD and mortality associated with interventions did not differ from those with placebo in either group. In conclusion, several interventions that affect risk of acute, mild to moderate, often temporary elevation in serum creatinine level in placebo-controlled randomized trials showed no appreciable effect on CKD or mortality months later, raising questions about the value of using small to moderate changes in serum creatinine level as end points in clinical trials. Copyright © 2016 by the American Society of Nephrology.

  2. Comparison of Three Methods Estimating Baseline Creatinine For Acute Kidney Injury in Hospitalized Patients: a Multicentre Survey in Third-Level Urban Hospitals of China.

    Science.gov (United States)

    Lang, Xia-Bing; Yang, Yi; Yang, Ju-Rong; Wan, Jian-Xin; Yu, Sheng-Qiang; Cui, Jiong; Tang, Xiao-Jing; Chen, Jianghua

    2018-01-01

    A lack of baseline serum creatinine (SCr) data leads to underestimation of the burden caused by acute kidney injury (AKI) in developing countries. The goal of this study was to investigate the effects of various baseline SCr analysis methods on the current diagnosis of AKI in hospitalized patients. Patients with at least one SCr value during their hospital stay between January 1, 2011 and December 31, 2012 were retrospectively included in the study. The baseline SCr was determined either by the minimum SCr (SCrMIN) or the estimated SCr using the MDRD formula (SCrGFR-75). We also used the dynamic baseline SCr (SCrdynamic) in accordance with the 7 day/48 hour time window. AKI was defined based on the KDIGO SCr criteria. Of 562,733 hospitalized patients, 350,458 (62.3%) had at least one SCr determination, and 146,185 (26.0%) had repeat SCr tests. AKI was diagnosed in 13,883 (2.5%) patients using the SCrMIN, 21,281 (3.8%) using the SCrGFR-75 and 9,288 (1.7%) using the SCrdynamic. Compared with the non-AKI patients, AKI patients had a higher in-hospital mortality rate regardless of the baseline SCr analysis method. Because of the scarcity of SCr data, imputation of the baseline SCr is necessary to remedy the missing data. The detection rate of AKI varies depending on the different imputation methods. SCrGFR-75 can identify more AKI cases than the other two methods. © 2018 The Author(s). Published by S. Karger AG, Basel.

  3. Comparison of Three Methods Estimating Baseline Creatinine For Acute Kidney Injury in Hospitalized Patients: a Multicentre Survey in Third-Level Urban Hospitals of China

    Directory of Open Access Journals (Sweden)

    Xia-bing Lang

    2018-02-01

    Full Text Available Background/Aims: A lack of baseline serum creatinine (SCr data leads to underestimation of the burden caused by acute kidney injury (AKI in developing countries. The goal of this study was to investigate the effects of various baseline SCr analysis methods on the current diagnosis of AKI in hospitalized patients. Methods: Patients with at least one SCr value during their hospital stay between January 1, 2011 and December 31, 2012 were retrospectively included in the study. The baseline SCr was determined either by the minimum SCr (SCrMIN or the estimated SCr using the MDRD formula (SCrGFR-75. We also used the dynamic baseline SCr (SCrdynamic in accordance with the 7 day/48 hour time window. AKI was defined based on the KDIGO SCr criteria. Results: Of 562,733 hospitalized patients, 350,458 (62.3% had at least one SCr determination, and 146,185 (26.0% had repeat SCr tests. AKI was diagnosed in 13,883 (2.5% patients using the SCrMIN, 21,281 (3.8% using the SCrGFR-75 and 9,288 (1.7% using the SCrdynamic. Compared with the non-AKI patients, AKI patients had a higher in-hospital mortality rate regardless of the baseline SCr analysis method. Conclusions: Because of the scarcity of SCr data, imputation of the baseline SCr is necessary to remedy the missing data. The detection rate of AKI varies depending on the different imputation methods. SCrGFR-75 can identify more AKI cases than the other two methods.

  4. How to use… serum creatinine, cystatin C and GFR.

    Science.gov (United States)

    Pasala, Swetha; Carmody, J Bryan

    2017-02-01

    Glomerular filtration rate (GFR) is the best overall measure of kidney function. The GFR is relatively low at birth but increases through infancy and early childhood to reach adult levels of approximately 120 mL/min/1.73 m 2 by age 2. While GFR can be measured most accurately by the urinary clearance of an exogenous ideal filtration marker such as inulin, it is more clinically useful to estimate GFR using a single serum measurement of an endogenous biomarker such as creatinine or cystatin C. When in steady state, there is an inverse relationship between creatinine/cystatin C and GFR, allowing GFR to be estimated from either using simple equations. Because of the non-linear relationship between creatinine/cystatin C and GFR, relatively small initial increases in these markers represent significant decreases in GFR. While cystatin C is produced by all nucleated cells, creatinine is a waste product of muscle metabolism and is therefore influenced by diet and muscle mass/body habitus. Decreased GFR is used to diagnose and stage chronic kidney disease (CKD) using the Kidney Disease: Improving Global Outcomes system. A diagnosis of CKD requires GFR creatinine and urine output are used to diagnose acute kidney injury. It is possible to calculate a kinetic GFR when the creatinine is changing rapidly, though more complex calculations are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  6. Effect of combined treatment of angiotensin converting enzyme inhibitors and diuretics on serum creatinine levels among elderly patients

    International Nuclear Information System (INIS)

    Sweileh, Waleed M.

    2006-01-01

    The adverse effects of angiotensin converting enzyme inhibitors (ACE-I) and diuretics when given together need extensive research and attention. We performed a cross-sectional study of patients admitted to the internal department of a general medical hospital to investigate the effect of drug combinations on serum creatinine level and creatinine clearance upon admission. Age, sex, disease, status and prior consumption of the target drugs: diuretics and ACE-I were correlated with creatnine and creatinine clearance on admission. The levels of serum creatinine for groups receiving the target combination in both sexes were significantly higher than groups who were not receiving the target combination. Computing an estimate of creatinine clearance based on Cockroft equation yields similar results to that for serum level creatinine. The levels of creatinine clearance in both sexes were significantly higher in the control group compared to those receiving the target combinations. Low dose aspirin seems to have a synergistic negative effect on renal function when given in combination with the target medications. Taking ACE-I/diuretic combination was associated with significant changes in creatinine levels and creatinine clearance. Attention should be made to balance positive effects of theses medications against their negative effect on renal function. (author)

  7. Preliminary Findings of Serum Creatinine and Estimated Glomerular Filtration Rate (eGFR) in Adolescents with Intellectual Disabilities

    Science.gov (United States)

    Lin, Jin-Ding; Lin, Lan-Ping; Hsieh, Molly; Lin, Pei-Ying

    2010-01-01

    The present study aimed to describe the kidney function profile--serum creatinine and estimated glomerular filtration rate (eGFR), and to examine the relationships of predisposing factors to abnormal serum creatinine in people with intellectual disabilities (ID). Data were collected by a cross-sectional study of 827 aged 15-18 years adolescents…

  8. Effects of Serum Creatinine Calibration on Estimated Renal Function in African Americans: the Jackson Heart Study

    Science.gov (United States)

    Wang, Wei; Young, Bessie A.; Fülöp, Tibor; de Boer, Ian H.; Boulware, L. Ebony; Katz, Ronit; Correa, Adolfo; Griswold, Michael E.

    2015-01-01

    Background The calibration to Isotope Dilution Mass Spectroscopy (IDMS) traceable creatinine is essential for valid use of the new Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation to estimate the glomerular filtration rate (GFR). Methods For 5,210 participants in the Jackson Heart Study (JHS), serum creatinine was measured with a multipoint enzymatic spectrophotometric assay at the baseline visit (2000–2004) and re-measured using the Roche enzymatic method, traceable to IDMS in a subset of 206 subjects. The 200 eligible samples (6 were excluded, 1 for failure of the re-measurement and 5 for outliers) were divided into three disjoint sets - training, validation, and test - to select a calibration model, estimate true errors, and assess performance of the final calibration equation. The calibration equation was applied to serum creatinine measurements of 5,210 participants to estimate GFR and the prevalence of CKD. Results The selected Deming regression model provided a slope of 0.968 (95% Confidence Interval (CI), 0.904 to 1.053) and intercept of −0.0248 (95% CI, −0.0862 to 0.0366) with R squared 0.9527. Calibrated serum creatinine showed high agreement with actual measurements when applying to the unused test set (concordance correlation coefficient 0.934, 95% CI, 0.894 to 0.960). The baseline prevalence of CKD in the JHS (2000–2004) was 6.30% using calibrated values, compared with 8.29% using non-calibrated serum creatinine with the CKD-EPI equation (P creatinine measurements in the JHS and the calibrated values provide a lower CKD prevalence estimate. PMID:25806862

  9. Effects of serum creatinine calibration on estimated renal function in african americans: the Jackson heart study.

    Science.gov (United States)

    Wang, Wei; Young, Bessie A; Fülöp, Tibor; de Boer, Ian H; Boulware, L Ebony; Katz, Ronit; Correa, Adolfo; Griswold, Michael E

    2015-05-01

    The calibration to isotope dilution mass spectrometry-traceable creatinine is essential for valid use of the new Chronic Kidney Disease Epidemiology Collaboration equation to estimate the glomerular filtration rate. For 5,210 participants in the Jackson Heart Study (JHS), serum creatinine was measured with a multipoint enzymatic spectrophotometric assay at the baseline visit (2000-2004) and remeasured using the Roche enzymatic method, traceable to isotope dilution mass spectrometry in a subset of 206 subjects. The 200 eligible samples (6 were excluded, 1 for failure of the remeasurement and 5 for outliers) were divided into 3 disjoint sets-training, validation and test-to select a calibration model, estimate true errors and assess performance of the final calibration equation. The calibration equation was applied to serum creatinine measurements of 5,210 participants to estimate glomerular filtration rate and the prevalence of chronic kidney disease (CKD). The selected Deming regression model provided a slope of 0.968 (95% confidence interval [CI], 0.904-1.053) and intercept of -0.0248 (95% CI, -0.0862 to 0.0366) with R value of 0.9527. Calibrated serum creatinine showed high agreement with actual measurements when applying to the unused test set (concordance correlation coefficient 0.934, 95% CI, 0.894-0.960). The baseline prevalence of CKD in the JHS (2000-2004) was 6.30% using calibrated values compared with 8.29% using noncalibrated serum creatinine with the Chronic Kidney Disease Epidemiology Collaboration equation (P creatinine measurements in the JHS, and the calibrated values provide a lower CKD prevalence estimate.

  10. Evaluation of Serum Cystatin C compared with Creatinine: A study in patients with Pre-eclampsia

    OpenAIRE

    Salma Malik Mmordas; Omer Fadol Edris

    2015-01-01

    This is cross sectional study aim to evaluate of serum Cystatin C and Creatinine level among pre-clampsia patients. Hundred subjects were evaluate in this study, 50 preclampsia patients as cases and 50 healthy apparently as control groups. Serum Cystatin C and Creatinine were measuring using MISP-i2, Mindray respectively. In assessment of renal function and compare with creatin in women which diagnostic   preeclampsia.  Result showed there was significant increase in mean concentration of Cys...

  11. Serum Cystatin C– Versus Creatinine-Based Definitions of Acute Kidney Injury Following Cardiac Surgery: A Prospective Cohort Study

    Science.gov (United States)

    Spahillari, Aferdita; Parikh, Chirag R.; Sint, Kyaw; Koyner, Jay L.; Patel, Uptal D.; Edelstein, Charles L.; Passik, Cary S.; Thiessen-Philbrook, Heather; Swaminathan, Madhav; Shlipak, Michael G.

    2012-01-01

    Background The primary aim of this study was to compare the sensitivity and rapidity of AKI detection by cystatin C relative to creatinine following cardiac surgery. Study Design Prospective cohort study Settings and Participants 1,150 high-risk, adult cardiac surgery patients in the TRIBE-AKI (Translational Research Investigating Biomarker Endpoints for Acute Kidney Injury) Consortium. Predictor Changes in serum creatinine and cystatin C Outcome Post-surgical incidence of AKI Measurements Serum creatinine and cystatin C were measured at the preoperative visit and daily on postoperative days 1–5. To allow comparisons between changes in creatinine and cystatin C, AKI endpoints were defined by the relative increases in each marker from baseline (25, 50 and 100%) and the incidence of AKI was compared based upon each marker. Secondary aims were to compare clinical outcomes among patients defined as having AKI by cystatin C and/or creatinine. Results Overall, serum creatinine detected more cases of AKI than cystatin C: 35% developed a ≥25% increase in serum creatinine, whereas only 23% had ≥25% increase in cystatin C (p Creatinine also had higher proportions meeting the 50% (14% and 8%, pcreatinine or cystatin C. However, for each AKI threshold, patients with AKI confirmed by both markers had significantly higher risk of the combined mortality/dialysis outcome compared with patients with AKI detected by creatinine alone (p=0.002). Limitations There were few adverse clinical outcomes, limiting our ability to detect differences in outcomes between subgroups of patients based upon their definitions of AKI. Conclusion In this large multicenter study, we found that cystatin C was less sensitive for AKI detection compared with creatinine. However, confirmation by cystatin C appeared to identify a subset of AKI patients with substantially higher risk of adverse outcomes. PMID:22809763

  12. Interdialytic creatinine change versus predialysis creatinine as indicators of nutritional status in maintenance hemodialysis

    Science.gov (United States)

    Walther, Carl P.; Carter, Caitlin Wise; Low, Chai L.; Williams, Peter; Rifkin, Dena E.; Steiner, Robert W.

    2012-01-01

    Background. Protein–energy wasting is common in patients on maintenance hemodialysis and is strongly associated with poor quality of life and mortality. However, clinical assessment of protein–energy wasting remains difficult. Predialysis creatinine levels are associated with mortality risk but may be influenced by both muscle mass and dialysis dose. This might be overcome by examining the rate of rise in creatinine between dialysis sessions. Methods. We conducted an observational cohort study among 81 patients on maintenance hemodialysis at our Veterans Affairs unit. Predialysis serum creatinine and change in serum creatinine between midweek dialysis sessions served as the predictor variables of interest and clinically available proxies of nutritional status and time to mortality served as the outcome variables. Linear regression and Cox proportional hazards models evaluated relationships, respectively. Results. The mean age of the study participants was 63 ± 10 years, 77 (95%) were male, mean body mass index was 27 ± 6 kg/m2 and 69% had diabetes. Median follow-up time was 13 months, during which 12 patients (15%) died. Interdialytic change in serum creatinine showed a strong direct correlation with predialysis serum creatinine (R = 0.96). Higher levels of both markers were associated with younger age, less residual urine volume and higher serum albumin, serum phosphorus and normalized protein catabolic rate (P creatinine tertile, participants in the lowest tertile (creatinine (change creatinine and interdialytic change in creatinine are both strongly associated with proxies of nutritional status and mortality in hemodialysis patients and are highly correlated. Interdialytic change in creatinine provided little additional information about nutritional status or mortality risk above and beyond predialysis creatinine levels alone. PMID:21775764

  13. Significant association of serum creatinine with HbA1C in impaired glucose tolerant Pakistani subjects.

    Science.gov (United States)

    Farasat, Tasnim; Sharif, Saima; Naz, Shagufta; Fazal, Sabiha

    2015-01-01

    The present study was conducted to assess the serum concentration of creatinine and determine its relationship with potential risk factors of diabetes in Impaired Glucose tolerance subjects. This cross sectional study was conducted on 100 IGT patients who attended Amin Hayat diabetic center in Lahore from January 2011- June 2011. Patients with age group 34-67 years, (both sexes) were included in the study. Different demographic parameters as age, BMI, WHR, B.P, personal history and socioeconomic status were recorded. Oral Glucose Tolerance Test was performed. The biochemical parameters including HbA1c, lipid profile, urea, uric acid, creatinine and bilirubin level were measured by chemistry analyzer. A strong correlation between creatinine and HbA1c was observed. The level of creatinine was also significantly associated with age in IGT subjects. Creatinine is non-significantly correlated with Cholesterol, LDL-Chol and TG while negatively significantly associated with BMI, fasting blood glucose and HDL-Chol. The present study concluded significant association of serum creatinine with HbA1c, BMI and HDL cholesterol.

  14. NephroCheck data compared to serum creatinine in various clinical settings.

    Science.gov (United States)

    Pajenda, Sahra; Ilhan-Mutlu, Aysegül; Preusser, Matthias; Roka, Sebastian; Druml, Wilfred; Wagner, Ludwig

    2015-12-09

    Acute kidney injury is frequently observed at the intensive care unit, after surgery, and after toxic drug administration. A rise in serum creatinine and a fall in urine output are consequences of much earlier injury to the most sensitive part of tubular cells located at the proximal tubule. The aim of the present study was to investigate the course of two cell-cycle arrest urinary biomarkers compared to serum creatinine in four clinical settings: ischemic reperfusion injury, cardiac failure, severe acute kidney injury, and chemotherapy-induced kidney injury. A recently developed bedside test known as NephroCheck measures two urinary parameters: insulin-like growth factor binding protein 7 (IGFBP7) and tissue inhibitor of metalloproteinase-2 (TIMP-2). The test is based on a sandwich immunoassay technique. The final test output, labeled AKIRisk, is shown as a numeric result. This report revealed that [IGFBP7] · [TIMP-2] in urine rise rapidly prior to any change in serum creatinine. A unique feature of all four clinical settings is that a rapid decline predicts the recovery of kidney function. Besides, a subclinical kidney injury might be detected by the test. This bedside test detects biomarkers of renal injury. A rapid decline in AKIRisk was associated with the restoration of kidney function, whereas a prolonged high AKIRisk score was associated with end-stage renal disease. However, the dynamics seem to differ, depending on the cause and the extent of injury. Further studies will be needed to clarify the issue.

  15. Creatinine blood test

    Science.gov (United States)

    Serum creatinine; Kidney function - creatinine; Renal function - creatinine ... kidney damage or failure, infection, or reduced blood flow Loss of ... medicine overdose. Your provider will tell you more, if needed.

  16. Serum Creatinine Changes Associated with Critical Illness and Detection of Persistent Renal Dysfunction after AKI

    Science.gov (United States)

    Kolic, Ivana; Purdell-Lewis, Jeremy; Taylor, Rachelle; Pearse, Rupert M.; Kirwan, Christopher J.

    2014-01-01

    Background and objectives AKI is a risk factor for development or worsening of CKD. However, diagnosis of renal dysfunction by serum creatinine could be confounded by loss of muscle mass and creatinine generation after critical illness. Design, setting, participants, & measurements A retrospective, single center analysis of serum in patients surviving to hospital discharge with an intensive care unit admission of 5 or more days between 2009 and 2011 was performed. Results In total, 700 cases were identified, with a 66% incidence of AKI. In 241 patients without AKI, creatinine was significantly lower (Pcreatinine was significantly lower than baseline in all patients except those patients with severe AKI (Kidney Disease Improving Global Outcomes category 3), who had no significant difference. In a multivariable regression model, median duration of hospitalization was associated with a predicted 30% decrease (95% confidence interval, 8% to 45%) in creatinine from baseline in the absence of AKI; after allowing for this effect, AKI was associated with a 29% (95% confidence interval, 10% to 51%) increase in predicted hospital discharge creatinine. Using a similar model to exclude the confounding effect of prolonged major illness on creatinine, 148 of 700 patients (95% confidence interval, 143 to 161) would have eGFRcreatinine (a 135% increase in potential CKD diagnoses; Pcreatinine that persist to hospital discharge, potentially causing inaccurate assessment of renal function at discharge, particularly in survivors of AKI. Prospective measurements of GFR and creatinine generation are required to confirm the significance of these findings. PMID:24742481

  17. Changes in serum cystatin C, creatinine, and C-reactive protein after cardiopulmonary bypass in patients with normal preoperative kidney function.

    Science.gov (United States)

    Svensson, Anders S; Kvitting, John-Peder Escobar; Kovesdy, Csaba P; Cederholm, Ingemar; Szabó, Zoltán

    2016-06-01

    The use of cardiopulmonary bypass (CPB) can cause changes in serum creatinine and cystatin C independent of glomerular filtration rate. We aimed to quantify the temporal changes of these biomarkers and C-reactive protein (CRP) after CPB. This was a prospective study at an academic medical centre between April and October 2013. We compared postoperative changes in serum creatinine and cystatin C in 38 patients with normal preoperative kidney function who underwent cardiac surgery using CPB and did not develop perioperative acute kidney injury (AKI). The effect of inflammation on intra-individual changes was examined in mixed effects regressions, using measurements of pre- and postoperative CRP. Both serum creatinine (79.9 ± 22.7 vs. 92.6 ± 21.4 µmol/L, P = 0.001) and cystatin C (1.16 ± 0.39 vs. 1.33 ± 0.37 mg/L, P = 0.012) decreased significantly in the first 8 h postoperatively compared to preoperatively, as a result of haemodilution. Thereafter serum creatinine returned to preoperative levels, whereas serum cystatin C continued to rise and was significantly elevated at 72 h post-CPB compared to preoperative levels (1.53 ± 0.48 vs. 1.33 ± 0.37 mg/L, P = 0.003). CRP levels increased significantly post-CPB and were significantly associated with increases in both serum creatinine and cystatin C. Serum creatinine and cystatin C appear not to be interchangeable biomarkers during and immediately after CPB. Processes unrelated to kidney function such as acute inflammation have a significant effect on post-CPB changes in these biomarkers, and may result in significant increases in serum cystatin C that could erroneously be interpreted as AKI. © 2015 Asian Pacific Society of Nephrology.

  18. Gender-Specific Differences in Baseline, Peak, and Delta Serum Creatinine: The NACSELD Experience.

    Science.gov (United States)

    O'Leary, Jacqueline G; Wong, Florence; Reddy, K Rajender; Garcia-Tsao, Guadalupe; Kamath, Patrick S; Biggins, Scott W; Fallon, Michael B; Subramanian, Ram M; Maliakkal, B; Thacker, Leroy; Bajaj, Jasmohan S

    2017-03-01

    Women have lower serum creatinine values than men for similar renal function. We aimed to determine the differential effect of baseline, peak, and delta creatinine between genders on outcomes in infected hospitalized cirrhotic patients. North American Consortium for the Study of End-Stage Liver Disease is a 15-center consortium of tertiary care hepatology centers prospectively enrolling infected cirrhotic inpatients. Baseline, peak, and delta creatinine during hospitalization were compared between genders, and their impact on overall survival, transplant-free survival, probability of transplantation, and need for renal replacement therapy (RRT) was analyzed. In total, 532 patients with cirrhosis (males = 59% median admission MELD = 20) had significantly lower median baseline (1.07 vs. 1.30 mg/dL, p creatinine (1.47 vs. 1.59 mg/dL, p = 0.024) in women than men during hospitalization for an infection, but both genders had similar delta creatinine levels (0.30 vs. 0.30 mg/dL, p = 0.957). Thirty-day mortality was similar between genders. RRT was not used more often in women (19 vs. 12%, p = 0.050), and women were 1.8 times more likely than men to receive RRT at the same creatinine (p = 0.028). Both peak and delta creatinine significantly predicted 6-month overall and transplant-free survival (p creatinine. Infected hospitalized cirrhotic women are significantly more likely than men to receive RRT at similar creatinine levels. Gender-specific differences in baseline, peak, and delta creatinine need further investigation to determine whether women need acute kidney injury treatment at lower creatinine thresholds than men.

  19. Changes in the level of urea, creatine and creatinine in the liver and serum of irradiated rats

    International Nuclear Information System (INIS)

    El Kashef, H.S.; Saada, H.N.

    1991-01-01

    This study aims to compare between the susceptibility of two tissues (liver and serum) toγ-radiation with respect to some protein end-products; namely urea, creatine and creatinine. The results indicated that in control rat liver, the concentration of urea, creatine and creatinine ranged between 262-266, 106-108 and 18.86-19.48 μg/g fresh tissue, respectively. In blood serum, the concentration of these end-products were 327-383, 94-97 and 12.36-12.51μg/ml blood serum. Whole body -irradiation at dose 5.5 Gy caused significant changes in the levels of both urea and creatine in the blood serum on the 7th and 14th post irradiation days, while the level of creatinine was not altered. As for the liver of whole body γ -irradiated rats, significant changes were observed in the content of urea at the all post-irradiation days except at the 3 rd day. The creatinine content of the liver was significantly decreased on the 3 rd, 14th and 21st days after irradiation. Similar decrease was noticed in the content of creatine, but on the 7th day, significant increase was observed. The variation in the studied parameters started early in the liver and lated longer, but it started later and lasted shorter in the serum of irradiated rats. It could be suggested that the liver of irradiated rats is more sensitive to the radiation dose 5.5 Gy than the blood.1 fig.,2 tab

  20. Prognosis and serum creatinine levels in acute renal failure at the time of nephrology consultation: an observational cohort study

    Directory of Open Access Journals (Sweden)

    de Irala Jokin

    2007-09-01

    Full Text Available Abstract Background The aim of this study is to evaluate the association between acute serum creatinine changes in acute renal failure (ARF, before specialized treatment begins, and in-hospital mortality, recovery of renal function, and overall mortality at 6 months, on an equal degree of ARF severity, using the RIFLE criteria, and comorbid illnesses. Methods Prospective cohort study of 1008 consecutive patients who had been diagnosed as having ARF, and had been admitted in an university-affiliated hospital over 10 years. Demographic, clinical information and outcomes were measured. After that, 646 patients who had presented enough increment in serum creatinine to qualify for the RIFLE criteria were included for subsequent analysis. The population was divided into two groups using the median serum creatinine change (101% as the cut-off value. Multivariate non-conditional logistic and linear regression models were used. Results A ≥ 101% increment of creatinine respect to its baseline before nephrology consultation was associated with significant increase of in-hospital mortality (35.6% vs. 22.6%, p Conclusion In this cohort, patients who had presented an increment in serum level of creatinine of ≥ 101% with respect to basal values, at the time of nephrology consultation, had increased mortality rates and were discharged from hospital with a more deteriorated renal function than those with similar Liano scoring and the same RIFLE classes, but with a

  1. Improving the measurement of longitudinal change in renal function: automated detection of changes in laboratory creatinine assay

    Directory of Open Access Journals (Sweden)

    Norman Poh

    2015-04-01

    Full Text Available IntroductionRenal function is reported using the estimates of glomerular filtration rate (eGFR. However, eGFR values are recorded without reference to the particular serum creatinine (SCr assays used to derive them, and newer assays were introduced at different time points across the laboratories in the United Kingdom. These changes may cause systematic bias in eGFR reported in routinely collected data, even though laboratory-reported eGFR values have a correction factor applied.DesignAn algorithm to detect changes in SCr that in turn affect eGFR calculation method was developed. It compares the mapping of SCr values on to eGFR values across a time series of paired eGFR and SCr measurements.SettingRoutinely collected primary care data from 20,000 people with the richest renal function data from the quality improvement in chronic kidney disease trial.ResultsThe algorithm identified a change in eGFR calculation method in 114 (90% of the 127 included practices. This change was identified in 4736 (23.7% patient time series analysed. This change in calibration method was found to cause a significant step change in the reported eGFR values, producing a systematic bias. The eGFR values could not be recalibrated by applying the Modification of Diet in Renal Disease equation to the laboratory reported SCr values.ConclusionsThis algorithm can identify laboratory changes in eGFR calculation methods and changes in SCr assay. Failure to account for these changes may misconstrue renal function changes over time. Researchers using routine eGFR data should account for these effects.  

  2. RENAL FUNCTION TEST ON THE BASIS OF SERUM CREATININE AND UREA IN TYPE-2 DIABETICS AND NONDIABETICS

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-01-01

    Full Text Available Background: Type-2 diabetes mellitus has quickly become a global health problem due to rapidly increasing population growth, aging, urbanization and increasing prevalence of obesity and physical inactivity. Diabetic nephropathy is one of the major causes of chronic renal failure. Both serum urea and creatinine are widely used to assess the function of kidney. This study was conducted to observe the impaired renal function in type 2 diabetics and compare with non-diabetics controls. Method: To determine the incidence of renal dysfunction in diabetics in Nepalgunj medical college and Hospital , Nepalgunj , Banke, Nepal , blood samples from 100 diabetic subjects and 100 non-diabetic controls were taken between the period 1st February  , 2012  to  31st January , 2013 for investigation of  plasma glucose fasting(FPG, blood urea and serum creatinine. These biochemical parameters were determined by using a fully automated clinical chemistry analyzer. Results: Our findings showed that the level of blood urea (P<0.0001, 95%Cl and serum creatinine (P≈0.0004,95%Cl were significantly higher in type 2 diabetics as compared to non-diabetics in both male and female. There was no significant difference between diabetic male and female. 15 out of 100 diabetes samples have high urea level whereas 7 out of 100 had increased creatinine level. In control only 3 samples had high urea value and 1 had high creatinine level. There was statistical significant increased in urea level with increased in blood sugar level. Conclusion: Blood urea and creatinine is widely accepted to assess the renal functions. Good control of blood glucose level is absolute requirement to prevent progressive renal impairment.

  3. Variability of creatinine measurements in clinical laboratories: results from the CRIC study.

    Science.gov (United States)

    Joffe, Marshall; Hsu, Chi-yuan; Feldman, Harold I; Weir, Matthew; Landis, J R; Hamm, L Lee

    2010-01-01

    Estimating equations using serum creatinine (SCr) are often used to assess glomerular filtration rate (GFR). Such creatinine (Cr)-based formulae may produce biased estimates of GFR when using Cr measurements that have not been calibrated to reference laboratories. In this paper, we sought to examine the degree of this variation in Cr assays in several laboratories associated with academic medical centers affiliated with the Chronic Renal Insufficiency Cohort (CRIC) Study; to consider how best to correct for this variation, and to quantify the impact of such corrections on eligibility for participation in CRIC. Variability of Cr is of particular concern in the conduct of CRIC, a large multicenter study of subjects with chronic renal disease, because eligibility for the study depends on Cr-based assessment of GFR. A library of 5 large volume plasma specimens from apheresis patients was assembled, representing levels of plasma Cr from 0.8 to 2.4 mg/dl. Samples from this library were used for measurement of Cr at each of the 14 CRIC laboratories repetitively over time. We used graphical displays and linear regression methods to examine the variability in Cr, and used linear regression to develop calibration equations. We also examined the impact of the various calibration equations on the proportion of subjects screened as potential participants who were actually eligible for the study. There was substantial variability in Cr assays across laboratories and over time. We developed calibration equations for each laboratory; these equations varied substantially among laboratories and somewhat over time in some laboratories. The laboratory site contributed the most to variability (51% of the variance unexplained by the specimen) and variation with time accounted for another 15%. In some laboratories, calibration equations resulted in differences in eligibility for CRIC of as much as 20%. The substantial variability in SCr assays across laboratories necessitates calibration

  4. Elevated serum creatinine and low albumin are associated with poor outcomes in patients with liposarcoma.

    Science.gov (United States)

    Panotopoulos, Joannis; Posch, Florian; Funovics, Philipp T; Willegger, Madeleine; Scharrer, Anke; Lamm, Wolfgang; Brodowicz, Thomas; Windhager, Reinhard; Ay, Cihan

    2016-03-01

    Low serum albumin levels and impaired kidney function have been associated with decreased survival in patients with a variety of cancer types. In a retrospective cohort study, we analyzed 84 patients with liposarcoma treated at from May 1994 to October 2011. Uni- and multivariable Cox proportional hazard models and competing risk analyses were performed to evaluate the association between putative biomarkers with disease-specific and overall survival. The median age of the study population was 51.7 (range 19.6-83.8) years. In multivariable analysis adjusted for AJCC tumor stage, serum creatinine was highly associated with disease-specific survival (Subdistribution Hazard ratio (SHR) per 1 mg/dl increase = 2.94; 95%CI 1.39-6.23; p = 0.005). High albumin was associated with improved overall and disease-specific survival (Hazard Ratio (HR) per 10 units increase = 0.50; 95%CI 0.26-0.95; p = 0.033 and SHR = 0.64; 95%CI 0.42-1.00; p = 0.049). The serum albumin-creatinine-ratio emerged to be associated with both overall and disease-specific survival after adjusting for AJCC tumor stage (HR = 0.95; 95%CI 0.92-0.99; p = 0.011 and SHR = 0.96; 95%CI 0.93-0.99; p = 0.08). Our study provides evidence for a tumor-stage-independent association between higher creatinine and lower albumin with worse disease-specific survival. Low albumin and a high albumin-creatinine-ratio independently predict poor overall survival. Our work identified novel prognostic biomarkers for prognosis of patients with liposarcoma. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Deceiving proteins! A case of lymphoma and high creatinine.

    Science.gov (United States)

    Metraiah, El Hakem Abdelkarim; Regan, Helen; Louw, Johanna; Kidder, Dana

    2017-01-23

    Estimation of kidney function by measuring serum creatinine is one the commonest laboratory tests conducted in clinical practice. Enzymatic methods are often used to measure serum creatinine. Clinicians should be aware of the limitations of these methods, such as test interference with paraproteins.We present a case of falsely elevated serum creatinine in a patient referred for renal biopsy. The combination of fluctuating creatinine and normal blood urea level was unusual. Serum protein electrophoresis revealed the presence of an IgM paraprotein. Further investigations confirmed an underlying diagnosis of lymphoplasmacytoid lymphoma. This case highlights how IgM paraprotein can interfere with creatinine estimation by enzymatic assay and the utility of alternative methods of estimating serum creatinine. 2017 BMJ Publishing Group Ltd.

  6. Superiority of Serum Cystatin C Over Creatinine in Prediction of Long-Term Prognosis at Discharge From ICU.

    Science.gov (United States)

    Ravn, Bo; Prowle, John R; Mårtensson, Johan; Martling, Claes-Roland; Bell, Max

    2017-09-01

    Renal outcomes after critical illness are seldom assessed despite strong correlation between chronic kidney disease and survival. Outside hospital, renal dysfunction is more strongly associated with mortality when assessed by serum cystatin C than by creatinine. The relationship between creatinine and longer term mortality might be particularly weak in survivors of critical illness. Retrospective observational cohort study. In 3,077 adult ICU survivors, we compared ICU discharge cystatin C and creatinine and their association with 1-year mortality. Exclusions were death within 72 hours of ICU discharge, ICU stay less than 24 hours, and end-stage renal disease. None. During ICU admission, serum cystatin C and creatinine diverged, so that by ICU discharge, almost twice as many patients had glomerular filtration rate less than 60 mL/min/1.73 m when estimated from cystatin C compared with glomerular filtration rate estimated from creatinine, 44% versus 26%. In 743 patients without acute kidney injury, where ICU discharge renal function should reflect ongoing baseline, discharge glomerular filtration rate estimated from creatinine consistently overestimated follow-up glomerular filtration rate estimated from creatinine, whereas ICU discharge glomerular filtration rate estimated from cystatin C well matched follow-up chronic kidney disease status. By 1 year, 535 (17.4%) had died. In survival analysis adjusted for age, sex, and comorbidity, cystatin C was near-linearly associated with increased mortality, hazard ratio equals to 1.78 (95% CI, 1.46-2.18), 75th versus 25th centile. Conversely, creatinine demonstrated a J-shaped relationship with mortality, so that in the majority of patients, there was no significant association with survival, hazard ratio equals to 1.03 (0.87-1.2), 75th versus 25th centile. After adjustment for both creatinine and cystatin C levels, higher discharge creatinine was then associated with lower long-term mortality. In contrast to creatinine

  7. Deceiving proteins! A case of lymphoma and high creatinine

    OpenAIRE

    Metraiah, El Hakem Abdelkarim; Regan, Helen; Louw, Johanna; Kidder, Dana

    2017-01-01

    Estimation of kidney function by measuring serum creatinine is one the commonest laboratory tests conducted in clinical practice. Enzymatic methods are often used to measure serum creatinine. Clinicians should be aware of the limitations of these methods, such as test interference with paraproteins.We present a case of falsely elevated serum creatinine in a patient referred for renal biopsy. The combination of fluctuating creatinine and normal blood urea level was unusual. Serum protein elect...

  8.  A Comparison of Serum Cystatin C and Creatinine with Glomerular FiltrationRate in Indian Patients with Chronic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Ramanathan Kumaresan

    2011-11-01

    Full Text Available  Objectives: There is no literature available on the performance of cystatin C in Chronic Kidney Disease (CKD patients of Indian population based on age group. Hence, this study is aimed to compare the diagnostic performance of serum cystatin C and creatinine with measured glomerular filtration rate (GFR and estimated GFR (eGFR in subjects of Indian origin. Methods: The study was carried out at Tiruchirappalli, South India during the period of September 2010 to march 2011. One hundred and six CKD patients (82 males, 24 females were enrolled and categorized into three groups based on age. The eGFR was calculated using Cockcroft-Gault (CG and Modification of Diet in Renal Disease (MDRD formulae. Serum cystatin C was measured with a particle-enhanced nephelometric immunoassay (PENIA method. GFR was measured using 99mTC - diethylene triamine penta aceticacid (DTPA renal scan method. Results: Serum cystatin C showed significant correlation with measured GFR in all the three groups (r=-0.9735, r=-0.8975 and r=-0.7994 respectively than serum creatinine (r=-0.7380, r=- 0.6852 and r=-0.5127 respectively. Conclusion: Serum cystatin C showed a high correlation with measured GFR in young and older patients with CKD than creatinine. Thus, cystatin C is a good alternative marker to creatinine in CKD patients.

  9. Serum creatinine may indicate risk of symptomatic intracranial hemorrhage after intravenous tissue plasminogen activator (IV tPA).

    Science.gov (United States)

    Marsh, Elisabeth B; Gottesman, Rebecca F; Hillis, Argye E; Urrutia, Victor C; Llinas, Rafael H

    2013-11-01

    Symptomatic intracranial hemorrhage (sICH) is a known complication following administration of intravenous tissue plasminogen activator (IV tPA) for acute ischemic stroke. sICH results in high rates of death or long-term disability. Our ability to predict its occurrence is important in clinical decision making and when counseling families. The initial National Institute of Neurological Disorders and Stroke (NINDS) investigators developed a list of relative contraindications to IV tPA meant to decrease the risk of subsequent sICH. To date, the impact of renal impairment has not been well studied. In the current study we evaluate the potential association between renal impairment and post-tPA intracranial hemorrhage (ICH). Admission serum creatinine and estimated glomerular filtration rate (eGFR) were recorded in 224 patients presenting within 4.5 hours from symptom onset and treated with IV tPA based on NINDS criteria. Neuroimaging was obtained 1 day post-tPA and for any change in neurologic status to evaluate for ICH. Images were retrospectively evaluated for hemorrhage by a board-certified neuroradiologist and 2 reviewers blinded to the patient's neurologic status. Medical records were reviewed retrospectively for evidence of neurologic decline indicating a "symptomatic" hemorrhage. sICH was defined as subjective clinical deterioration (documented by the primary neurology team) and hemorrhage on neuroimaging that was felt to be the most likely cause. Renal impairment was evaluated using both serum creatinine and eGFR in a number of ways: 1) continuous creatinine; 2) any renal impairment by creatinine (serum creatinine >1.0 mg/dL); 3) continuous eGFR; and 4) any renal impairment by eGFR (eGFR creatinine >1.0 mg/dL) was not associated with combined symptomatic and asymptomatic intracranial bleeding (p = 0.359); however, there was an adjusted 5.5-fold increased odds of sICH when creatinine was >1.0 mg/dL (95% confidence interval, 1.08-28.39), and the frequency of s

  10. Prognostic Importance of Low Admission Serum Creatinine Concentration for Mortality in Hospitalized Patients.

    Science.gov (United States)

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Kittanamongkolchai, Wonngarm; Harrison, Andrew M; Kashani, Kianoush

    2017-05-01

    The study objective was to assess the association between low serum creatinine value at admission and in-hospital mortality in hospitalized patients. This was a retrospective single-center cohort study conducted at a tertiary referral hospital. All hospitalized adult patients between 2011 and 2013 who had an admission creatinine value available were identified for inclusion in this study. Admission creatinine value was categorized into 7 groups: ≤0.4, 0.5 to 0.6, 0.7 to 0.8, 0.9 to 1.0, 1.1 to 1.2, 1.3 to 1.4, and ≥1.5 mg/dL. The primary outcome was in-hospital mortality. Logistic regression analysis was performed to obtain the odds ratio of in-hospital mortality for the various admission creatinine levels, using a creatinine value of 0.7 to 0.8 mg/dL as the reference group in the analysis of all patients and female patients and of 0.9 to 1.0 mg/dL in the analysis of male patients because it was associated with the lowest in-hospital mortality. Of 73,994 included patients, 973 (1.3%) died in the hospital. The association between different categories of admission creatinine value and in-hospital mortality assumed a U-shaped distribution, with both low and high creatinine values associated with higher in-hospital mortality. After adjustment for age, sex, ethnicity, principal diagnosis, and comorbid conditions, very low creatinine value (≤0.4 mg/dL) was significantly associated with increased mortality (odds ratio, 3.29; 95% confidence interval, 2.08-5.00), exceeding the risk related to a markedly increased creatinine value of ≥1.5 mg/dL (odds ratio, 2.56; 95% confidence interval, 2.07-3.17). The association remained significant in the subgroup analysis of male and female patients. Low creatinine value at admission is independently associated with increased in-hospital mortality in hospitalized patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  12. Comparison of Two Creatinine-Based Equations for Predicting Decline in Renal Function in Type 2 Diabetic Patients with Nephropathy in a Korean Population

    Directory of Open Access Journals (Sweden)

    Eun Young Lee

    2013-01-01

    Full Text Available Aim. To compare two creatinine-based estimated glomerular filtration rate (eGFR equations, the chronic kidney disease epidemiology collaboration (CKD-EPI and the modification of diet in renal disease (MDRD, for predicting the risk of CKD progression in type 2 diabetic patients with nephropathy. Methods. A total of 707 type 2 diabetic patients with 24 hr urinary albumin excretion of more than 30 mg/day were retrospectively recruited and traced until doubling of baseline serum creatinine (SCr levels was noted. Results. During the follow-up period (median, 2.4 years, the CKD-EPI equation reclassified 10.9% of all MDRD-estimated subjects: 9.1% to an earlier stage of CKD and 1.8% to a later stage of CKD. Overall, the prevalence of CKD (eGFR < 60 mL/min/1.73 m2 was lowered from 54% to 51.6% by applying the CKD-EPI equation. On Cox-regression analysis, both equations exhibited significant associations with an increased risk for doubling of SCr. However, only the CKD-EPI equation maintained a significant hazard ratio for doubling of SCr in earlier-stage CKD (eGFR ≥ 45 mL/min/1.73 m2, when compared to stage 1 CKD (eGFR ≥ 90 mL/min/1.73 m2. Conclusion. In regard to CKD progression, these results suggest that the CKD-EPI equation might more accurately stratify earlier-stage CKD among type 2 diabetic patients with nephropathy than the MDRD study equation.

  13. Serum uric acid to creatinine ratio: A predictor of incident chronic kidney disease in type 2 diabetes mellitus patients with preserved kidney function.

    Science.gov (United States)

    Gu, Liubao; Huang, Liji; Wu, Haidi; Lou, Qinglin; Bian, Rongwen

    2017-05-01

    Serum uric acid has shown to be a predictor of renal disease progression in most but not all studies. This study aims to test whether renal function-normalized serum uric acid is superior to serum uric acid as the predictor of incident chronic kidney disease in type 2 diabetes mellitus patients. In this study, 1339 type 2 diabetes mellitus patients with estimated glomerular filtration rate ⩾60 mL/min/1.73 m 2 and normouricemia were included. Renal function-normalized serum uric acid was calculated using serum uric acid/creatinine. Cox regression analysis was used to estimate the association between serum uric acid, renal function-normalized serum uric acid and incident chronic kidney disease. In total, 74 (5.53%) patients developed to chronic kidney disease 3 or greater during a median follow-up of 4 years, with older ages, longer diabetes duration and lower estimated glomerular filtration rate at baseline. The decline rate of estimated glomerular filtration rate was positively correlated with serum uric acid/creatinine ( r = 0.219, p uric acid ( r = 0.005, p = 0.858). Moreover, multivariate analysis revealed that serum uric acid was not an independent risk factor for incident chronic kidney disease ( p = 0.055), whereas serum uric acid to creatinine ratio was significantly associated with incident chronic kidney disease independently of potential confounders including baseline estimated glomerular filtration rate. serum uric acid to creatinine ratio might be a better predictor of incident chronic kidney disease in type 2 diabetes mellitus patients.

  14. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  15. Association of lean body mass with nutritional parameters and mortality in hemodialysis patients: A long-term follow-up clinical study.

    Science.gov (United States)

    Zhou, Dong Chi; Yang, Xiu Hong; Zhan, Xiao Li; Gu, Yan Hong; Guo, Li Li; Jin, Hui Min

    2018-06-01

    This study aimed to evaluate the correlation between lean body mass (LBM) and nutritional status in hemodialysis (HD) patients to better predict their long-term prognosis. Anthropometric body measurements and biochemical parameters were recorded from 222 patients on maintenance hemodialysis (MHD) at the Shanghai Pudong Hospital Hemodialysis Center. LBM was calculated using the serum creatinine index (LBM-SCR), mid-arm muscle circumference (LBM-MAMC), and dominant-arm hand-grip strength (LBM-HGS). Patient mortality and hospitalization were observed after 24 months. LBMs measured from LBM-SCR and LBM-MAMC were associated with sex, body mass index (BMI), serum albumin, and serum creatinine (SCR) ( p LBM evaluation, low LBM was shown to be associated with a higher mortality in patients undergoing HD ( p LBM-SCR and LBM-HGS are strongly associated with hospitalization and mortality in HD patients, indicating LBM is an important factor in prediction of outcomes in those patients. LBM is associated with nutritional parameters in HD patients, and LBM-SCR, HGS, and MAMC are simple approaches for accurately predicting the patient's risk of hospitalization and/or death.

  16. Serum lipoprotein (a) concentration in patients with nephrotic syndrome and its clinical implication.

    Science.gov (United States)

    Yang, X; Wang, H; Zhu, Z; Deng, A

    1998-01-01

    Serum lipoprotein(a) [Lp(a)] concentration was determined in 42 patients with primary nephrotic syndrome (NS) and the relationships between Lp (a) and plasma lipids, apolipoproteins, serum creatinine (Scr), albumin, urinary proteins (Upro) were also analyzed. The results showed that: (1) serum Lp(a) concentrations in the patients with NS were higher than those in healthy controls; (2) the levels of serum Lp(a) were correlated positively with total cholesterol (TC), low density lipoprotein cholesterol (LDL-C), very low density lipoprotein cholesterol (VLDL-C), apolipoprotein B (Apo-B), Upros (Upro). It is concluded that the NS patients had the potential risk of suffering from coronary artery disease, glomerular sclerosis and thrombosis. The remission of NS may partially decrease the serum Lp(a) levels. Further studies are needed to explore the prevention and treatment of dislipedemia in patients with NS.

  17. Blood urea nitrogen to serum creatinine ratio is an accurate predictor of outcome in diarrhea-associated hemolytic uremic syndrome, a preliminary study.

    Science.gov (United States)

    Keenswijk, Werner; Vanmassenhove, Jill; Raes, Ann; Dhont, Evelyn; Vande Walle, Johan

    2017-03-01

    Diarrhea-associated hemolytic uremic syndrome (D+HUS) is a common thrombotic microangiopathy during childhood and early identification of parameters predicting poor outcome could enable timely intervention. This study aims to establish the accuracy of BUN-to-serum creatinine ratio at admission, in addition to other parameters in predicting the clinical course and outcome. Records were searched for children between 1 January 2008 and 1 January 2015 admitted with D+HUS. A complicated course was defined as developing one or more of the following: neurological dysfunction, pancreatitis, cardiac or pulmonary involvement, hemodynamic instability, and hematologic complications while poor outcome was defined by death or development of chronic kidney disease. Thirty-four children were included from which 11 with a complicated disease course/poor outcome. Risk of a complicated course/poor outcome was strongly associated with oliguria (p = 0.000006) and hypertension (p = 0.00003) at presentation. In addition, higher serum creatinine (p = 0.000006) and sLDH (p = 0.02) with lower BUN-to-serum creatinine ratio (p = 0.000007) were significantly associated with development of complications. A BUN-to-sCreatinine ratio ≤40 at admission was a sensitive and highly specific predictor of a complicated disease course/poor outcome. A BUN-to-serum Creatinine ratio can accurately identify children with D+HUS at risk for a complicated course and poor outcome. What is Known: • Oliguria is a predictor of poor long-term outcome in D+HUS What is New: • BUN-to-serum Creatinine ratio at admission is an entirely novel and accurate predictor of poor outcome and complicated clinical outcome in D+HUS • Early detection of the high risk group in D+HUS enabling early treatment and adequate monitoring.

  18. The Effect of Calcusol™ to the Plasma Free Radical and Serum Creatinin in Mus Musculus Nephrolithiasis Model

    Directory of Open Access Journals (Sweden)

    A’liyatur Rosyidah

    2013-09-01

    Full Text Available Calcusol™ is a traditional medicine (jamu made from Tempuyung (Sonchus arvensis extract and is usually used for cure kidney stone disease. However, there has not been any studies which investigate the its mechanism. The aim of this study is to know the effect of Calcusol™ to the plasma free radical and serum creatinin of Mus musculus model for renal calcium-oxalate accumulation. This study is carried out by administration of Porang (Amorphophallus muelleri tuber flour for 3 months with the doses 6 mg/100g BW to induce renal calcium oxalate accumulation and Calcusol™ treatment for 7 days with the doses of 3.3mg/g BW. Group I was used as a control group. Group II was only given porang every day for 3 months. Group III was only given Calcusol™ for 7 days. Group IV were given porang for 3 months then given Calcusol™ for 7 days. Group V were given porang and Calcusol™ simultaneously for 3 months. Porang and CalcusolTM is administrated orally. Blood was collected from the tail of the animal for serum creatinin test and plasma free radical test using TBARS method. The data was analyzed using ANOVA followed by Tukey HSD to compare the means employing SPSS 16.0 for windows. The result of the research shows that the treatment Calcusol™ on mice model for renal calcium oxalate accumulation. The content of MDA at group I, group II, group III, group IV and group V, respectivelyis 0.81±0.5 mg/ml; 2.63±0.8 mg/ml; 0.56±0.5 mg/ml; 2.09±0.9 mg/ml and 0.17±0.17 mg/ml. The content of serum creatinine are 0.15±0.04 mg/dL; 0.13±0.03 mg/dL; 0.12±0.08 mg/dL; 0.11±0.016 mg/dL and 0.14±0.015 mg/dL at group I, group II, group III, Group IV, and group V respectively. This indicates that Calcusol™ decreases plasma free radical production during renal stone formation, while serum creatinin reduced but not significantly changed. Calcusol™ has an effect to decrease free radical during renalstone formation inmice model for calcium oxalate accumulation

  19. Antimalarial drug induced decrease in creatinine clearance

    NARCIS (Netherlands)

    Landewé, R. B.; Vergouwen, M. S.; Goeei The, S. G.; van Rijthoven, A. W.; Breedveld, F. C.; Dijkmans, B. A.

    1995-01-01

    To confirm the antimalarial drug induced increase of creatinine to determine the factors contributing to this effect. Patients with rheumatoid arthritis (RA) (n = 118) who have used or still use antimalarials (chloroquine or hydroxychloroquine). Serum creatinines prior to antimalarials and serum

  20. RELATIONSHIP BETWEEN URIC ACID METABOLISM AND INSULIN RESISTANCE

    OpenAIRE

    辻本, 伸宏; 金内, 雅夫; 尾崎, 博基; 藤田, 泰三; 中嶋, 民夫; 土肥, 和紘

    1998-01-01

    To investigate the relationship between uric acid (UA) metabolism and insulin resistance, serum creatinine concentration (Scr), serum UA concentration (SuA) and the urinary excretion of creatinine and UA were determined in 25 non-diabetic patients. Creatinine clearance (Ccr) and UA clearance/creatinine clearance ratio (CuA/Ccr) were also calculated. Insulin resistance was evaluated by the euglycemic glucose clamp tech- nique and expressed as the mean value of the glucose infusion rate (M-valu...

  1. Diabetic Nephropathy and CKD?Analysis of Individual Patient Serum Creatinine Trajectories: A Forgotten Diagnostic Methodology for Diabetic CKD Prognostication and Prediction

    OpenAIRE

    Onuigbo, Macaulay Amechi Chukwukadibia; Agbasi, Nneoma

    2015-01-01

    Creatinine is produced in muscle metabolism as the end-product of creatine phosphate and is subsequently excreted principally by way of the kidneys, predominantly by glomerular filtration. Blood creatinine assays constitute the most common clinically relevant measure of renal function. The use of individual patient-level real-time serum creatinine trajectories provides a very attractive and tantalizing methodology in nephrology practice. Topics covered in this review include acute kidney inju...

  2. Low Body Mass Index, Serum Creatinine, and Cause of Death in Patients Undergoing Percutaneous Coronary Intervention.

    Science.gov (United States)

    Goel, Kashish; Gulati, Rajiv; Reeder, Guy S; Lennon, Ryan J; Lewis, Bradley R; Behfar, Atta; Sandhu, Gurpreet S; Rihal, Charanjit S; Singh, Mandeep

    2016-10-31

    Low body mass index (BMI) and serum creatinine are surrogate markers of frailty and sarcopenia. Their relationship with cause-specific mortality in elderly patients undergoing percutaneous coronary intervention is not well studied. We determined long-term cardiovascular and noncardiovascular mortality in 9394 consecutive patients aged ≥65 years who underwent percutaneous coronary intervention from 2000 to 2011. BMI and serum creatinine were divided into 4 categories. During a median follow-up of 4.2 years (interquartile range 1.8-7.3 years), 3243 patients (33.4%) died. In the multivariable model, compared with patients with normal BMI, patients with low BMI had significantly increased all-cause mortality (hazard ratio [HR] 1.4, 95% CI 1.1-1.7), which was related to both cardiovascular causes (HR 1.4, 95% CI 1.0-1.8) and noncardiovascular causes (HR 1.4, 95% CI 1.06-1.9). Compared with normal BMI, significant reduction was noted in patients who were overweight and obese in terms of cardiovascular mortality (overweight: HR 0.77, 95% CI 0.67-0.88; obese: HR 0.80, 95% CI 0.70-0.93) and noncardiovascular mortality (overweight: HR 0.85, 95% CI 0.74-0.97; obese: HR 0.82, 95% CI 0.72-0.95). In a multivariable model, in patients with normal BMI, low creatinine (≤0.70 mg/dL) was significantly associated with increased all-cause mortality (HR 1.8, 95% CI 1.3-2.5) and cardiovascular mortality (HR 2.3, 95% CI 1.4-3.8) compared with patients with normal creatinine (0.71-1.0 mg/dL); however, this was not observed in other BMI categories. We identified a new subgroup of patients with low serum creatinine and normal BMI that was associated with increased all-cause mortality and cardiovascular mortality in elderly patients undergoing percutaneous coronary intervention. Low BMI was associated with increased cardiovascular and noncardiovascular mortality. Nutritional support, resistance training, and weight-gain strategies may have potential roles for these patients undergoing

  3. Blood creatinine level in postmortem cases.

    Science.gov (United States)

    Nishida, Atsushi; Funaki, Hironao; Kobayashi, Masaki; Tanaka, Yuka; Akasaka, Yoshihisa; Kubo, Toshikazu; Ikegaya, Hiroshi

    2015-05-01

    Blood chemical analysis for the diagnosis of diseases in forensic cases should be conducted in the same way as for clinical cases. However, it is sometimes difficult to obtain serum samples in forensic cases because of postmortem changes such as hemolysis and putrefaction. This study aimed to evaluate renal function in postmortem cases by blood creatinine analysis. The blood creatinine level was measured by high performance liquid chromatography (HPLC) using whole blood samples taken from 77 postmortem cases, and the relationships between blood creatinine level, postmortem interval, and cause of death were examined. The median blood creatinine level was found to be 1.15 mg/dL, with no significant differences between blood samples taken from different parts of the body. The blood creatinine level was stable for 3 days after death and gradually increased after that period, in line with a previous study using enzymatic analysis that found the serum creatinine level was stable in the early postmortem period. The blood creatinine level was high in the cases of blunt injury, intoxication, and in deaths caused by fire. This was considered to reflect acute renal dysfunction. However, the postmortem blood creatinine level remained higher than the clinical normal value despite omitting cases with renal dysfunction from the analysis. Therefore, we next investigated the change in postmortem creatinine levels in mice and found that the blood creatinine level increased with the emergence of rigor mortis. Our findings indicate that HPLC is useful in the postmortem evaluation of renal function even in the cases where serum cannot be obtained. However, the presence of rigor mortis should be considered in the evaluation of blood creatinine values. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  4. Trends in serum creatinine testing in Oxfordshire, UK, 1993-2013: a population-based cohort study.

    Science.gov (United States)

    Oke, Jason; Shine, Brian; McFadden, Emily; Stevens, Richard; Lasserson, Daniel; Perera, Rafael

    2015-12-16

    To determine how many kidney function tests are done, on whom, how frequently they are performed and how they have changed over time. Retrospective study of all serum creatinine, urine albumin and urine creatinine tests. Primary and secondary care in Oxfordshire from 1993 to 2013. Unselected population of 1,220,447 people. The total number of creatinine and urinary protein tests ordered from primary and secondary care and the number of tests per year stratified by categories of estimated glomerular filtration rate (eGFR). The frequency of testing in patients having their kidney function monitored. Creatinine requests from primary care increased steadily from 1997 and exceeded 220,000 requests in 2013. Tests corresponding to normal kidney function (eGFR >60/mL/min/1.73 m(2)) constituted 59% of all kidney function tests in 1993 and accounted for 83% of all tests in 2013. Test corresponding to chronic kidney disease (CKD) stages 3-5 declined after 2007. Reduced kidney function, albuminuria, male gender, diabetes and age were independently associated with more frequent monitoring. For a female patient between 61 and 80 years and with stage 3a CKD, the average number of serum creatinine tests (95% CI) was 3.23/year (3.19 to 3.26) and for a similar woman with diabetes, the average number of tests was 5.50 (5.44 to 5.56) tests per year. There has been a large increase in the number of kidney function tests over the past two decades. However, we found little evidence that this increase is detecting more CKD. Tests are becoming more frequent in people with and without evidence of renal impairment. Future work using a richer data source could help unravel the underlying reasons for the increased testing and determine how much is necessary and useful. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Don Kyoung; Choi, See Min; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun [Sungkyunkwan University School of Medicine, Department of Urology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Bong Hee [The Catholic University of Korea College of Medicine, Department of Urology, Incheon St. Mary' s Hospital, Seoul (Korea, Republic of)

    2015-11-15

    We aimed to evaluate the performance of various GFR estimates compared with direct measurement of GFR (dGFR). We also sought to create a new formula for volume-based GFR (new-vGFR) using kidney volume determined by CT. GFR was measured using creatinine-based methods (MDRD, the Cockcroft-Gault equation, CKD-EPI formula, and the Mayo clinic formula) and the Herts method, which is volume-based (vGFR). We compared performance between GFR estimates and created a new vGFR model by multiple linear regression analysis. Among the creatinine-based GFR estimates, the MDRD and C-G equations were similarly associated with dGFR (correlation and concordance coefficients of 0.359 and 0.369 and 0.354 and 0.318, respectively). We developed the following new kidney volume-based GFR formula: 217.48-0.39XA + 0.25XW-0.46XH-54.01XsCr + 0.02XV-19.89 (if female) (A = age, W = weight, H = height, sCr = serum creatinine level, V = total kidney volume). The MDRD and CKD-EPI had relatively better accuracy than the other creatinine-based methods (30.7 % vs. 32.3 % within 10 % and 78.0 % vs. 73.0 % within 30 %, respectively). However, the new-vGFR formula had the most accurate results among all of the analyzed methods (37.4 % within 10 % and 84.6 % within 30 %). The new-vGFR can replace dGFR or creatinine-based GFR for assessing kidney function in donors and healthy individuals. (orig.)

  6. Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs

    International Nuclear Information System (INIS)

    Choi, Don Kyoung; Choi, See Min; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun; Park, Bong Hee

    2015-01-01

    We aimed to evaluate the performance of various GFR estimates compared with direct measurement of GFR (dGFR). We also sought to create a new formula for volume-based GFR (new-vGFR) using kidney volume determined by CT. GFR was measured using creatinine-based methods (MDRD, the Cockcroft-Gault equation, CKD-EPI formula, and the Mayo clinic formula) and the Herts method, which is volume-based (vGFR). We compared performance between GFR estimates and created a new vGFR model by multiple linear regression analysis. Among the creatinine-based GFR estimates, the MDRD and C-G equations were similarly associated with dGFR (correlation and concordance coefficients of 0.359 and 0.369 and 0.354 and 0.318, respectively). We developed the following new kidney volume-based GFR formula: 217.48-0.39XA + 0.25XW-0.46XH-54.01XsCr + 0.02XV-19.89 (if female) (A = age, W = weight, H = height, sCr = serum creatinine level, V = total kidney volume). The MDRD and CKD-EPI had relatively better accuracy than the other creatinine-based methods (30.7 % vs. 32.3 % within 10 % and 78.0 % vs. 73.0 % within 30 %, respectively). However, the new-vGFR formula had the most accurate results among all of the analyzed methods (37.4 % within 10 % and 84.6 % within 30 %). The new-vGFR can replace dGFR or creatinine-based GFR for assessing kidney function in donors and healthy individuals. (orig.)

  7. Concurrence of Serum Creatinine and Albumin with Lower Risk for Death in Twice-Weekly Hemodialysis Patients

    Science.gov (United States)

    Wang, Jialin; Streja, Elani; Soohoo, Melissa; Chen, Joline L.T.; Rhee, Connie M.; Kim, Taehee; Molnar, Miklos Z.; Kovesdy, Csaba P.; Mehrotra, Rajnish; Kalantar-Zadeh, Kamyar

    2016-01-01

    Objective Markers of better nutritional status including both higher levels of serum albumin (as a measure of visceral proteins) and creatinine (as a measure of the muscle mass) are associated with lower mortality in conventional (thrice-weekly) hemodialysis patients. However, data for these associations in twice-weekly hemodialysis patients, in whom less frequent hemodialysis may confound nutritional predictors, are lacking. Design, Settings and Subjects We identified 1,113 twice-weekly and matched 4,448 thrice-weekly hemodialysis patients from a large national dialysis cohort of incident hemodialysis patients over 5 years (2007-2011). Mortality risk, adjusted for potential confounders, was examined across two-by-two combinations of serum creatinine (creatinine≥6mg/dl and albumin≥3.5g/dl as reference, patients with creatininecreatinine mortality associations between twice-weekly and thrice-weekly hemodialysis patients (p-for-interaction 0.7667). Conclusions Surrogate markers of higher visceral protein and muscle mass combined may confer greatest survival in both twice-weekly and thrice-weekly hemodialysis patients. PMID:27528412

  8. High serum creatinine nonlinearity: a renal vital sign?

    Science.gov (United States)

    Palant, Carlos E; Chawla, Lakhmir S; Faselis, Charles; Li, Ping; Pallone, Thomas L; Kimmel, Paul L; Amdur, Richard L

    2016-08-01

    Patients with chronic kidney disease (CKD) may have nonlinear serum creatinine concentration (SC) trajectories, especially as CKD progresses. Variability in SC is associated with renal failure and death. However, present methods for measuring SC variability are unsatisfactory because they blend information about SC slope and variance. We propose an improved method for defining and calculating a patient's SC slope and variance so that they are mathematically distinct, and we test these methods in a large sample of US veterans, examining the correlation of SC slope and SC nonlinearity (SCNL) and the association of SCNL with time to stage 4 CKD (CKD4) and death. We found a strong correlation between SCNL and rate of CKD progression, time to CKD4, and time to death, even in patients with normal renal function. We therefore argue that SCNL may be a measure of renal autoregulatory dysfunction that provides an early warning sign for CKD progression. Copyright © 2016 the American Physiological Society.

  9. Mechanisms Underlying Early Rapid Increases in Creatinine in Paraquat Poisoning

    Science.gov (United States)

    Mohamed, Fahim; Endre, Zoltan; Jayamanne, Shaluka; Pianta, Timothy; Peake, Philip; Palangasinghe, Chathura; Chathuranga, Umesh; Jayasekera, Kithsiri; Wunnapuk, Klintean; Shihana, Fathima; Shahmy, Seyed; Buckley, Nicholas

    2015-01-01

    Background Acute kidney injury (AKI) is common after severe paraquat poisoning and usually heralds a fatal outcome. The rapid large increases in serum creatinine (Cr) exceed that which can be explained by creatinine kinetics based on loss of glomerular filtration rate (GFR). Methods and Findings This prospective multi-centre study compared the kinetics of two surrogate markers of GFR, serum creatinine and serum cystatin C (CysC), following paraquat poisoning to understand and assess renal functional loss after paraquat poisoning. Sixty-six acute paraquat poisoning patients admitted to medical units of five hospitals were included. Relative changes in creatinine and CysC were monitored in serial blood and urine samples, and influences of non-renal factors were also studied. Results Forty-eight of 66 patients developed AKI (AKIN criteria), with 37 (56%) developing moderate to severe AKI (AKIN stage 2 or 3). The 37 patients showed rapid increases in creatinine of >100% within 24 hours, >200% within 48 hours and >300% by 72 hours and 17 of the 37 died. CysC concentration increased by 50% at 24 hours in the same 37 patients and then remained constant. The creatinine/CysC ratio increased 8 fold over 72 hours. There was a modest fall in urinary creatinine and serum/urine creatinine ratios and a moderate increase in urinary paraquat during first three days. Conclusion Loss of renal function contributes modestly to the large increases in creatinine following paraquat poisoning. The rapid rise in serum creatinine most probably represents increased production of creatine and creatinine to meet the energy demand following severe oxidative stress. Minor contributions include increased cyclisation of creatine to creatinine because of acidosis and competitive or non-competitive inhibition of creatinine secretion. Creatinine is not a good marker of renal functional loss after paraquat poisoning and renal injury should be evaluated using more specific biomarkers of renal injury

  10. Lipid and Creatinine Adjustment to Evaluate Health Effects of Environmental Exposures.

    Science.gov (United States)

    O'Brien, Katie M; Upson, Kristen; Buckley, Jessie P

    2017-03-01

    Urine- and serum-based biomarkers are useful for assessing individuals' exposure to environmental factors. However, variations in urinary creatinine (a measure of dilution) or serum lipid levels, if not adequately corrected for, can directly impact biomarker concentrations and bias exposure-disease association measures. Recent methodological literature has considered the complex relationships between creatinine or serum lipid levels, exposure biomarkers, outcomes, and other potentially relevant factors using directed acyclic graphs and simulation studies. The optimal measures of urinary dilution and serum lipids have also been investigated. Existing evidence supports the use of covariate-adjusted standardization plus creatinine adjustment for urinary biomarkers and standardization plus serum lipid adjustment for lipophilic, serum-based biomarkers. It is unclear which urinary dilution measure is best, but all serum lipid measures performed similarly. Future research should assess methods for pooled biomarkers and for studying diseases and exposures that affect creatinine or serum lipids directly.

  11. Reduced production of creatinine limits its use as marker of kidney injury in sepsis.

    Science.gov (United States)

    Doi, Kent; Yuen, Peter S T; Eisner, Christoph; Hu, Xuzhen; Leelahavanichkul, Asada; Schnermann, Jürgen; Star, Robert A

    2009-06-01

    Although diagnosis and staging of acute kidney injury uses serum creatinine, acute changes in creatinine lag behind both renal injury and recovery. The risk for mortality increases when acute kidney injury accompanies sepsis; therefore, we sought to explore the limitations of serum creatinine in this setting. In mice, induction of sepsis by cecal ligation and puncture in bilaterally nephrectomized mice increased markers of nonrenal organ injury and serum TNF-alpha. Serum creatinine, however, was significantly lower in septic animals than in animals subjected to bilateral nephrectomy and sham cecal ligation and puncture. Under these conditions treatment with chloroquine decreased nonrenal organ injury markers but paradoxically increased serum creatinine. Sepsis dramatically decreased production of creatinine in nephrectomized mice, without changes in body weight, hematocrit, or extracellular fluid volume. In conclusion, sepsis reduces production of creatinine, which blunts the increase in serum creatinine after sepsis, potentially limiting the early detection of acute kidney injury. This may partially explain why small absolute increases in serum creatinine levels are associated with poor clinical outcomes. These data support the need for new biomarkers that provide better measures of renal injury, especially in patients with sepsis.

  12. Use of cystatin C and serum creatinine for the diagnosis of contrast-induced nephropathy in patients undergoing contrast-enhanced computed tomography at an oncology centre.

    Directory of Open Access Journals (Sweden)

    Joao Italo Fortalesa Melo

    Full Text Available Our aim was to assess renal function using as laboratory measurements serum creatinine and cystatin C concentrations before and after administration of low-osmolarity (nonionic iodinated contrast medium in patients with cancer undergoing computed tomography (CT.This prospective study included 400 oncologic outpatients. Serum creatinine and cystatin C concentrations were measured before and 72 h after contrast administration. Glomerular filtration rates (GFRs were estimated using serum creatinine-based [Modification of Diet in Renal Disease (MDRD and Cockroft-Gault and cystatin C based (Larsson equations. Exploratory data analysis was performed. The nonparametric Wilcoxon test was used to compare pre and post contrast of test results and estimated clearance. The confidence interval used in the analysis was 95%.Compared with the pre-contrast values, the mean serum creatinine concentration was significantly higher and average GFRs estimated using MDRD and Cockcroft-Gault equations were significantly lower after the administration of contrast (p <0.001. It was also observed a significant increase after contrast in the concentration of Cystatin C (p = 0.015. In addition, a decrease in GFR estimated using the average Larsson (p = 0.021 was observed between time points. However, none of the patients presented clinically significant nephropathy.Assessment using serum creatinine and cystatin C concentrations showed changes in renal function among patients with cancer undergoing contrast-enhanced CT examination in this study. No significant renal damage related to the use of low-osmolarity iodinated contrast medium of the type and dosage employed in this study was observed. This contrast medium is thus safe for use in patients with cancer.

  13. Serum creatinine level: a supplemental index to distinguish Duchenne muscular dystrophy from Becker muscular dystrophy.

    Science.gov (United States)

    Zhang, Huili; Zhu, Yuling; Sun, Yiming; Liang, Yingyin; Li, Yaqin; Zhang, Yu; Deng, Langhui; Wen, Xingxuan; Zhang, Cheng

    2015-01-01

    To improve assessment of dystrophinopathy, the aim of this study was to identify whether serum creatinine (Crn) level reflects disease severity. Biochemical, Vignos score, and genetic data were collected on 212 boys with dystrophinopathy. Serum Crn level had a strong inverse correlation with Vignos score by simple correlation (r = -0.793) and partial correlation analysis after adjustment for age, height, and weight (r = -0.791; both P Becker muscular dystrophy (BMD) patients than Duchenne muscular dystrophy (DMD) patients at ages 4, 5, 7, and 9 yr (all P < 0.0125). After adjusting for age, height, and weight, BMD patients still had a significantly higher serum Crn level than DMD patients (β = 7.140,  t = 6.277,  P < 0.01). Serum Crn level reflected disease severity and may serve as a supplemental index to distinguish DMD from BMD in clinical practice.

  14. Strong negative interference of ethamsylate (Dicynone®) in serum creatinine quantification via enzymatic assay using Trinder reaction.

    Science.gov (United States)

    Wiewiorka, Ondrej; Dastych, Milan; Čermáková, Zdenka

    2013-08-01

    With discrepancies encountered as early as the verification of enzymatic method for quantification of serum creatinine, our research pointed to a later confirmed interference caused by a compound called ethamsylate present in the commonly used antihemorrhagic drug Dicynone. We measured concentrations of creatinine of 10 patients with blood taken before and 15 minutes after the intravenous administration of a 500 mg dose of Dicynone. The creatinine concentration was determined using Jaffe method and enzymatic method that utilize Trinder reaction (Roche) in analyzer Cobas c 501 (Roche AG, Basel, Switzerland). We also monitored concentration of blood creatinine in three patients before and 15 minutes after application of Dicynone (500 mg i.v.) and in the following 6th, 12th, 18th, and 24th hours. We discovered a significant negative bias in creatinine results using enzymatic assay with Trinder reaction in blood taken 15 min after i.v. application of 500 mg Dicynone to patients compared to their pre-application values (average decrease of 47%). Unlike this, the results of compensated Jaffe method yielded steady results in all samples (average deviation 0.6% from original values). However, 12 h after the drug administration comparable results were seen as before the administration. Considering the strong negative interference of ethamsylate in enzymatic assay using Trinder reaction for creatinine quantification, blood from patients with prescribed Dicynone should be taken at least 12 h after the last application of the drug for obtaining the correct creatinine values.

  15. Doubling of serum creatinine and the risk of cardiovascular outcomes in patients with chronic kidney disease and type 2 diabetes mellitus: a cohort study

    Directory of Open Access Journals (Sweden)

    Schneider C

    2016-06-01

    Full Text Available Cornelia Schneider,1,2 Blai Coll,3 Susan S Jick,4 Christoph R Meier1,2,4 1Basel Pharmacoepidemiology Unit, Division of Clinical Pharmacy and Epidemiology, Department of Pharmaceutical Sciences, University of Basel, Basel, Switzerland; 2Hospital Pharmacy, University Hospital Basel, Basel, Switzerland; 3Renal Development, AbbVie, North Chicago, IL, USA; 4Boston Collaborative Drug Surveillance Program, Boston University School of Public Health, MA, USA Background: Doubling of serum creatinine is often used as a marker for worsening kidney function in nephrology trials. Most people with chronic kidney disease die of other causes before reaching end-stage renal disease. We were interested in the association between doubling of serum creatinine and the risk of a first-time diagnosis of angina pectoris, congestive heart failure (CHF, myocardial infarction (MI, stroke, or transient ischemic attack in patients with chronic kidney disease and with diagnosed type 2 diabetes mellitus. Methods: We identified all adult patients registered in the “Clinical Practice Research Datalink” between 2002 and 2011 with incident chronic kidney disease and type 2 diabetes mellitus and did a cohort study with a Cox proportional hazard analysis. Results: We identified in total 27,811 patients, 693 developed angina pectoris, 1,069 CHF, 508 MI, 970 stroke, and 578 transient ischemic attacks. Patients whose serum creatinine doubled during follow-up had increased risks of CHF (hazard ratio [HR] 2.98, 95% confidence interval [CI] 2.27–3.89, MI (HR 2.53, 95% CI 1.62–3.96, and stroke (HR 1.93, 95% CI 1.38–2.69, as compared with patients whose serum creatinine did not double. The relative risks of angina pectoris (HR 1.18, 95% CI 0.66–2.10 or a transient ischemic attack (HR 1.32, 95% CI 0.78–2.22 were similar in both groups. Conclusion: Diabetic patients with a doubling of serum creatinine were at an increased risk of CHF, MI, or stroke, compared with diabetic

  16. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  17. Role of MELD score and serum creatinine as prognostic tools for the development of acute kidney injury after liver transplantation.

    Directory of Open Access Journals (Sweden)

    Thiago Gomes Romano

    Full Text Available BACKGROUND: The role of the Model for End-Stage Liver Disease (MELD score in predicting complications, such as Acute Kidney Injury (AKI, after orthotopic liver transplantation (OLT has yet to be evaluated and serum creatinine may be too heavily weighted in the existing MELD formula, since it has many pitfalls in cirrhotic patients. METHODS: Retrospective data of the perioperative period from consecutive adult OLTs performed from January to December 2009 were recorded. Univariate and multivariate analysis were performed to analyze the risk factors for AKI and mortality after OLT. RESULTS: There were 114 OLTs performed in the study period, 22 (19,2% were submitted to dialysis prior OLT and were excluded from the analysis for AKI. The median age was 52 years and 66% were male. Median creatinine value was 0.85mg/dL and MELD was 19. Fifty-two of the 92 patients (56,5% developed AKI in the first 72 hours after OLT. The only independent risk factor for AKI was calculated MELD and when the components of the MELD score were analyzed, INR had a much stronger impact in predicting AKI then serum creatinine. Overall mortality rate was 32,5% and anesthesia duration was the only variable associated with higher mortality rate. CONCLUSIONS: Although MELD score seems to have a good performance in predicting AKI after OLT, serum creatinine had no impact on its prediction despite its importance on MELD calculation. Modifying the MELD score, which could include novel AKI biomarkers, may improve its prognostic accuracy and provide a better tool for public health planning.

  18. Reduced Production of Creatinine Limits Its Use as Marker of Kidney Injury in Sepsis

    OpenAIRE

    Doi, Kent; Yuen, Peter S.T.; Eisner, Christoph; Hu, Xuzhen; Leelahavanichkul, Asada; Schnermann, Jürgen; Star, Robert A.

    2009-01-01

    Although diagnosis and staging of acute kidney injury uses serum creatinine, acute changes in creatinine lag behind both renal injury and recovery. The risk for mortality increases when acute kidney injury accompanies sepsis; therefore, we sought to explore the limitations of serum creatinine in this setting. In mice, induction of sepsis by cecal ligation and puncture in bilaterally nephrectomized mice increased markers of nonrenal organ injury and serum TNF-α. Serum creatinine, however, was ...

  19. Variation in Serum Creatinine Level Is Correlated to Risk of Type 2 Diabetes

    OpenAIRE

    Jun Sung Moon; Ji Eun Lee; Ji Sung Yoon

    2013-01-01

    Background Skeletal muscle is well established as a major target organ of insulin action, and is associated with the pathogenesis of type 2 diabetes. Therefore, we attempted to determine whether a variation in serum creatinine is related to the development of type 2 diabetes and other risk factors for diabetes. Methods A total of 2,676 nondiabetic subjects with stable and normal renal function (estimated glomerular filtration rate >60 mL/min/1.73 m2) were followed up for approximately 4.5 yea...

  20. Comparison of the Efficacy of Serum Creatinine and Microalbuminuria in Early Diagnosis of Renal Injury in Asphyxiated Infants in Calabar, Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Sunny Oteikwu Ochigbo

    2017-06-01

    Full Text Available Background: Microalbuminuria and serum creatinine are the specific markers of acute renal injury. Perinatal asphyxia is responsible for 50% of all neonatal deaths and nonoliguric acute renal injuryis one of its complications. This study was undertaken to determine the efficacy of serum creatinine and microalbuminuria for early diagnosis of renal injury in severely asphyxiated neonates in Calabar, Nigeria.Methods: This prospective cross-sectional study was performed among severely asphyxiated newborns admitted into the neonatal wards of the University of Calabar Teaching Hospital (UCTH. Standard methods for the determination of blood urea and electrolyte were executed. Micral-test strips have been applied using urine dipstick and the result of the test was negative only for albumin. The developed colors have been compared five minutes after the first test.Results: Fifty full-term newborns were enrolled and their serum electrolytes, creatinine and the creatinine clearance were essentially normal. Six neonates demonstrated positive results in the microalbominuria assessment, while the rest were negative in this regard. The test has 0% sensitivity and 100% specificity, while the positive and negative predictive values were 0% and 88%, respectively.Conclusion: Microalbuminuria is not a useful marker for early diagnosis of acute renal failure in the newborns with severe prenatal asphyxia, but further studies are recommended.

  1. Serum Creatinine Level: A Supplemental Index to Distinguish Duchenne Muscular Dystrophy from Becker Muscular Dystrophy

    Directory of Open Access Journals (Sweden)

    Huili Zhang

    2015-01-01

    Full Text Available Background. To improve assessment of dystrophinopathy, the aim of this study was to identify whether serum creatinine (Crn level reflects disease severity. Methods. Biochemical, Vignos score, and genetic data were collected on 212 boys with dystrophinopathy. Results. Serum Crn level had a strong inverse correlation with Vignos score by simple correlation (r=-0.793 and partial correlation analysis after adjustment for age, height, and weight (r=-0.791; both P<0.01. Serum Crn level was significantly higher in patients with in-frame than out-of-frame mutations (Z=-4.716, P<0.01 and in Becker muscular dystrophy (BMD patients than Duchenne muscular dystrophy (DMD patients at ages 4, 5, 7, and 9 yr (all P<0.0125. After adjusting for age, height, and weight, BMD patients still had a significantly higher serum Crn level than DMD patients (β=7.140, t=6.277, P<0.01. Conclusions. Serum Crn level reflected disease severity and may serve as a supplemental index to distinguish DMD from BMD in clinical practice.

  2. Evaluation of formulas using the serum creatinine level to calculate the optimal dosage of carboplatin.

    Science.gov (United States)

    van Warmerdam, L J; Rodenhuis, S; ten Bokkel Huinink, W W; Maes, R A; Beijnen, J H

    1996-01-01

    Carboplatin is a chemotherapeutic agent frequently used in the treatment of various malignancies. An individual dosing strategy has been recommended to yield the most optimal exposure, expressed as the area under the concentration-time curve (AUC). The formula developed by Calvert et al. (dose = target-AUC x [GFR + 25]) can be used to achieve this. However, due to the inconvenient [51Cr]-ethylenediamine-tetraacetic acid ([51Cr]-EDTA)-based measurement of the glomerular filtration rate (GFR), its application in the clinic has thus far been limited. Chatelut and co-workers have recently proposed a formula to estimate carboplatin clearance using the serum creatinine concentration. We retrospectively tested the Chatelut equation and the Calvert formula using either the creatinine clearance based on 24-h urine collection or the creatinine clearance based on the formula of Cockcroft and Gault. The latter equations were shown to predict the carboplatin clearance reasonably well, although systematic overprediction and underprediction occurred. However, the formula proposed by Chatelut and co-workers had no significant bias and was precise. It is proposed that this formula be used to calculate the optimal carboplatin dosage after prospective validation has been performed.

  3. The Significance of Serum beta2-Microglobulin Measurement in Various Renal Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Koong, Sung Soo; Oh, Ha Yong; Han, Jin Suk; Lee, Jung Sang [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1985-03-15

    To evaluate change of serum beta{sub 2}-microglobulin concentration (sbeta{sub 2}-MG) and the usefulness of sbeta{sub 2}-MG and sbeta{sub 2}-MG/serum creatinine concentration (sCr) ratio in various renal diseases, sbeta{sub 2}-MG and sCr were measured in 25 normal controls and 90 patients of various renal diseases (16 cases of glomerulonephritis, 12 cases of acute renal failure, 8 cases of chronic renal failure, 24 cases of nephrotic syndrome, 15 cases of tubulointerstitial diseases and 15 cases of lupus nephritis) using Phadebas beta{sub 2}-Micro Test kits. The results were as follows; 1) In normal control, the mean value of sbeta{sub 2}-MG was 1.65+-0.41 mg/l and the mean value of sbeta{sub 2}-MG/sCr ratio was 0.14+-0.05. 2) In various renal diseases, the mean value of sbeta{sub 2}-MG was 6.74+-5.47 mg/l. The mean value of sbeta{sub 2}-MG/sCr ratio was 0.24+-0.11 and significantly elevated than that of normal contro1. (P<0.05). 3) The correlation between sbeta-2-MG and sCr in glomerular and tubulointerstitial disease was log sbeta{sub 2}-MG=0.90 log sCr-0.48 and its correlation coefficient was 0.78 (P<0.05). 4) In glomerular disease, the correlation between sbeta{sub 2}-MG and sCr was log sbeta{sub 2}-MG=0.89 log sCr-0.46 (r-0.76) and in tubulointerstitial disease, it was log sbeta{sub 2}-MG=0.95 1og sCr-0.59 (r-0.87). There was no significant difference between the two groups (p<0.05). 5) Among 32 cases of glomerular and tubulointerstitial disease patients, whose sCr was within normal range, 17 cases showed elevated sbeta{sub 2}-MG. The mean values of sbeta{sub 2}-MG/sCr ratio in these patients was 0.30+-0.14 and significantly elevated than that of normal control (p<0.05). 6) In 15 cases of lupus nephritis, 12 cases showed elevated sbeta{sub 2}-MG with normal sCr and 12 cases showed elevated sbeta{sub 2}-MG/sCr ratio. With above results, It was found that the sbeta{sub 2}-MG can be used as an index of glomerular filtration rate as in the case of sCr and thats

  4. THE PATTERN OF LONGITUDINAL CHANGE IN SERUM CREATININE AND NINETY-DAY MORTALITY AFTER MAJOR SURGERY

    Science.gov (United States)

    Hobson, Charles E; Pardalos, Panos

    2016-01-01

    Objective Calculate mortality risk that accounts for both severity and recovery of postoperative kidney dysfunction using the pattern of longitudinal change in creatinine. Summary Background Data Although the importance of renal recovery after acute kidney injury (AKI) is increasingly recognized, the complex association that accounts for longitudinal creatinine changes and mortality is not fully described. Methods We used routinely collected clinical information for 46,299 adult patients undergoing major surgery to develop a multivariable probabilistic model optimized for non-linearity of serum creatinine time series that calculates the risk function for ninety-day mortality. We performed a 70/30 cross validation analysis to assess the accuracy of the model. Results All creatinine time series exhibited nonlinear risk function in relation to ninety-day mortality and their addition to other clinical factors improved the model discrimination. For any given severity of AKI, patients with complete renal recovery, as manifested by the return of the discharge creatinine to the baseline value, experienced a significant decrease in the odds of dying within ninety days of admission compared to patients with partial recovery. Yet, for any severity of AKI even complete renal recovery did not entirely mitigate the increased odds of dying as patients with mild AKI and complete renal recovery still had significantly increased odds for dying compared to patients without AKI (odds ratio 1,48 (95% confidence interval 1.30-1.68). Conclusions We demonstrate the nonlinear relationship between both severity and recovery of renal dysfunction and ninety-day mortality after major surgery. We have developed an easily applicable computer algorithm that calculates this complex relationship. PMID:26181482

  5. C-reactive protein and serum creatinine, but not haemoglobin A1c, are independent predictors of coronary heart disease risk in non-diabetic Chinese.

    Science.gov (United States)

    Salim, Agus; Tai, E Shyong; Tan, Vincent Y; Welsh, Alan H; Liew, Reginald; Naidoo, Nasheen; Wu, Yi; Yuan, Jian-Min; Koh, Woon P; van Dam, Rob M

    2016-08-01

    In western populations, high-sensitivity C-reactive protein (hsCRP), and to a lesser degree serum creatinine and haemoglobin A1c, predict risk of coronary heart disease (CHD). However, data on Asian populations that are increasingly affected by CHD are sparse and it is not clear whether these biomarkers can be used to improve CHD risk classification. We conducted a nested case-control study within the Singapore Chinese Health Study cohort, with incident 'hard' CHD (myocardial infarction or CHD death) as an outcome. We used data from 965 men (298 cases, 667 controls) and 528 women (143 cases, 385 controls) to examine the utility of hsCRP, serum creatinine and haemoglobin A1c in improving the prediction of CHD risk over and above traditional risk factors for CHD included in the ATP III model. For each sex, the performance of models with only traditional risk factors used in the ATP III model was compared with models with the biomarkers added using weighted Cox proportional hazards analysis. The impact of adding these biomarkers was assessed using the net reclassification improvement index. For men, loge hsCRP (hazard ratio 1.25, 95% confidence interval: 1.05; 1.49) and loge serum creatinine (hazard ratio 4.82, 95% confidence interval: 2.10; 11.04) showed statistically significantly associations with CHD risk when added to the ATP III model. We did not observe a significant association between loge haemoglobin A1c and CHD risk (hazard ratio 1.83, 95% confidence interval: 0.21; 16.06). Adding hsCRP and serum creatinine to the ATP III model improved risk classification in men with a net gain of 6.3% of cases (p-value = 0.001) being reclassified to a higher risk category, while it did not significantly reduce the accuracy of classification for non-cases. For women, squared hsCRP was borderline significantly (hazard ratio 1.01, 95% confidence interval: 1.00; 1.03) and squared serum creatinine was significantly (hazard ratio 1.81, 95% confidence interval: 1.49; 2

  6. Creatinine index as a surrogate of lean body mass derived from urea Kt/V, pre-dialysis serum levels and anthropometric characteristics of haemodialysis patients.

    Directory of Open Access Journals (Sweden)

    Bernard Canaud

    Full Text Available BACKGROUND AND OBJECTIVES: Protein-energy wasting is common in long-term haemodialysis (HD patients with chronic kidney disease and is associated with increased morbidity and mortality. The creatinine index (CI is a simple and useful nutritional parameter reflecting the dietary skeletal muscle protein intake and skeletal muscle mass of the patient. Because of the complexity of creatinine kinetic modeling (CKM to derive CI, we developed a more simplified formula to estimate CI in HD patients. DESIGN, SETTING, PARTICIPANTS & MEASUREMENTS: A large database of 549 HD patients followed over more than 20 years including monthly CKM-derived CI values was used to develop a simple equation based on patient demographics, predialysis serum creatinine values and dialysis dose (spKt/V using mixed regression models. RESULTS: The equation to estimate CI was developed based on age, gender, pre-dialysis serum creatinine concentrations and spKt/V urea. The equation-derived CI correlated strongly with the measured CI using CKM (correlation coefficient  = 0.79, p-value <0.001. The mean error of CI prediction using the equation was 13.47%. Preliminary examples of few typical HD patients have been used to illustrate the clinical relevance and potential usefulness of CI. CONCLUSIONS: The elementary equation used to derive CI using demographic parameters, pre-dialysis serum creatinine concentrations and dialysis dose is a simple and accurate surrogate measure for muscle mass estimation. However, the predictive value of the simplified CI assessment method on mortality deserves further evaluation in large cohorts of HD patients.

  7. CCQM-K11.2 determination of glucose in human serum and CCQM-K12.2 determination of creatinine in human serum

    Science.gov (United States)

    Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pritchett, Jeanita; Pabello, Guiomar; Avila Calderon, Marco A.; Balderas, Miryan; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Monteiro, Tânia; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Peignaux, Maryline; Kawaguchi, Migaku; Bei, Xu; Can, Quan; Nammoonnoy, Jintana; Schild, Katrin; Ohlendorf, Rüdiger; Henrion, Andre; Ceyhan Gören, Ahmet; Yılmaz, Hasibe; Bilsel, Mine; Konopelko, L.; Krylov, A.; Lopushanskaya, E.

    2018-01-01

    Glucose and creatinine are two of the most frequently measured substances in human blood/serum for assessing the health status of individuals. Because of their clinical significance, CCQM-K11 glucose in human serum and CCQM-K12 creatinine in human serum were the fourth and fifth key comparisons (KCs) performed by the Organic Analysis Working Group (OAWG). These KCs were conducted in parallel and were completed in 2001. The initial subsequent KCs for glucose, CCQM-K11.1, and creatinine, CCQM-K12.1, were completed in 2005. Measurements for the next KCs for these two measurands, CCQM-K11.2 and CCQM-K12.2, were completed in 2013. While designed as subsequent KCs, systematic discordances between the participants' and the anchor institution's results in both comparisons lead the OAWG to request reference results from two experienced laboratories that had participated in the 2001 comparisons. Based on the totality of the available information, the OAWG converted both CCQM-K11.2 and CCQM-K12.2 to 'Track C' KCs where the key comparison reference value is estimated by consensus. These comparisons highlighted that carrying out comparisons for complex chemical measurements and expecting to be able to treat them under the approaches used for formal CIPM subsequent comparisons is not an appropriate strategy. The approach used here is a compromise to gain the best value from the comparison; it is not an approach that will be used in the future. Instead, the OAWG will focus on Track A and Track C comparisons that are treated as stand-alone entities. Participation in CCQM-K11.2 demonstrates a laboratory's capabilities to measure a polar (pKow > 2), low molecular mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (0.1 mg/g to 10 mg/g). Participation in CCQM-K12.2 demonstrates capabilities to measure similar classes of metabolites at relatively low concentrations (1 μg/g to 30 μg/g). The capabilities required for the analysis of complex

  8. Estimating the concentration of urea and creatinine in the human serum of normal and dialysis patients through Raman spectroscopy.

    Science.gov (United States)

    de Almeida, Maurício Liberal; Saatkamp, Cassiano Junior; Fernandes, Adriana Barrinha; Pinheiro, Antonio Luiz Barbosa; Silveira, Landulfo

    2016-09-01

    Urea and creatinine are commonly used as biomarkers of renal function. Abnormal concentrations of these biomarkers are indicative of pathological processes such as renal failure. This study aimed to develop a model based on Raman spectroscopy to estimate the concentration values of urea and creatinine in human serum. Blood sera from 55 clinically normal subjects and 47 patients with chronic kidney disease undergoing dialysis were collected, and concentrations of urea and creatinine were determined by spectrophotometric methods. A Raman spectrum was obtained with a high-resolution dispersive Raman spectrometer (830 nm). A spectral model was developed based on partial least squares (PLS), where the concentrations of urea and creatinine were correlated with the Raman features. Principal components analysis (PCA) was used to discriminate dialysis patients from normal subjects. The PLS model showed r = 0.97 and r = 0.93 for urea and creatinine, respectively. The root mean square errors of cross-validation (RMSECV) for the model were 17.6 and 1.94 mg/dL, respectively. PCA showed high discrimination between dialysis and normality (95 % accuracy). The Raman technique was able to determine the concentrations with low error and to discriminate dialysis from normal subjects, consistent with a rapid and low-cost test.

  9. Methods for Quantitative Creatinine Determination.

    Science.gov (United States)

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  10. Technical presentation of SCR

    CERN Multimedia

    FI Department

    2008-01-01

    SCR Société des Composants Record, Montierchaume, France Monday 20 October 2008 from 9:45 to 12:00 – Room A Main Building (Bldg. 61/1-017) http://www.scr.fr SCR develops, manufactures and markets plastic dielectric capacitors (polypropylene, polyester, Teflon) for use in various applications: audio amplifiers, high-end loudspeakers, fans and extractors (multi-capacitance capacitors), pulsed lasers, flash lamps, defibrillators, beacons, power supplies, converters for rail traction drives, railway signalling devices, voltage dividers and multipliers, high voltage laboratories, etc. The company is renowned for its precision wire-wound resistors for use in power electronics and consumer electronics marketed under the SETA brand name. SCR is also experienced in the design and production of electronic circuits for various applications, such as speed variators for mono and three-phase motors, dimmers, passive filters for audio speakers, etc. Contact : M. Urs V. Rölli, e-mail: mailto:info@technictrade.ch.

  11. Serum cystatin C levels in preterm newborns in our setting: Correlation with serum creatinine and preterm pathologies.

    Science.gov (United States)

    Bardallo Cruzado, Leonor; Pérez González, Elena; Martínez Martos, Zoraima; Bermudo Guitarte, Carmen; Granero Asencio, Mercedes; Luna Lagares, Salud; Marín Patón, Mariano; Polo Padilla, Juan

    2015-01-01

    Cystatin C (CysC) is a renal function marker that is not as influenced as creatinine (Cr) by endogenous or exogenous agents, so it is therefore proposed as a marker in preterm infants. To determine serum CysC values in preterm infants during the first week of life, compared to Cr. To analyze alterations caused by prematurity diseases. The design involved a longitudinal, observational study of prospective cohorts. Groups were based on gestational age (GA): Group A (24-27 weeks), Group B (28-33 weeks), Group C (34-36 weeks). Blood samples were collected at birth, within 48-72hours and after 7 days of life. SPSS v.20 software was used. The statistical methods applied included chi-squared test and ANOVA. A total of 109 preterm infants were included in the study. CysC levels were: 1.54mg/L (±0.28) at birth; 1.38mg/L (±0.36) within 48-72hours of life; 1.50mg/L (±0.31) after 7 days (p<0.05). Cr levels were: 0.64mg/dL (±0.17) at birth; 0.64mg/dL (±0.28) within 48-72hours; 0.56mg/dL (±0.19) after 7 days (P<.05). CysC values were lower in hypotensive patients and those with a respiratory disease (P<.05), and no alterations associated with other diseases were observed. There were no differences in Cr levels associated with any disease. Creatinine levels were higher in patients ≤1.500g (P<.05). Serum CysC decreased within 48-72hours of life, and this decline showed significance (P<.05). The levels increased after 7 days in all 3 GA groups, and there was no difference in CysC levels among the groups. More studies in preterm infants with hypotension and respiratory disease are required. CysC is a better glomerular filtration (GF) marker in ≤1.500g preterm infants. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  12. Therapeutic effect of continuous exercise training program on serum creatinine concentration in men with hypertension: a randomized controlled trial.

    Science.gov (United States)

    Sikiru, L; Okoye, G C

    2014-09-01

    Creatinine (Cr) has been implicated as an independent predictor of hypertension and exercise has been reported as adjunct therapy for hypertension. The purpose of the present study was to investigate the effect of continuous training programme on blood pressure and serum creatinine concentration in black African subjects with hypertension. Three hundred and fifty seven male patients with mild to moderate (systolic blood pressure [SBP] between 140-180 & diastolic blood pressure [DBP] between 90-109 mmHg) essential hypertension were age matched and randomly grouped into continuous & control groups. The continuous group involved in an 8 weeks continuous training (60-79% HR reserve) of between 45 minutes to 60 minutes, 3 times per week, while the control group remain sedentary. SBP, DBP, VO2max, serum Cr, body mass index (BMI), waist hip ratio (WHR) and percent (%) body fat. Analysis of covariance (ANCOVA) and Pearson correlation tests were used in data analysis. Findings of the study revealed significant decreased effects of continuous training programme on SBP, DBP, Cr, BMI, WHR, % body fat and significant increase in VO2max at pexercise training as a multi-therapy in the down regulation of blood pressure, serum Cr, body size and body fat in hypertension.

  13. Effect of Vitamin D Receptor Activators on Glomerular Filtration Rate: A Meta-Analysis and Systematic Review.

    Directory of Open Access Journals (Sweden)

    Qian Zhang

    Full Text Available Vitamin D receptor activators (VDRAs can protect against mineral bone disease, but they are reported to elevate serum creatinine (SCr and may also reduce glomerular filtration rate (GFR.We conducted a systematic review and meta-analysis of randomized clinical trials (RCTs to evaluate the effect of VDRAs on kidney function and adverse events. MEDLINE, EMBASE, the Cochrane Controlled Trials Register were searched for RCTs that evaluate vitamin D receptor activators (alfacalcidol, calcitriol, doxercalciferol, falecalcitriol, maxacalcitol and paricalcitol up to March 2015.We included 31 studies, all of which were performed between 1976 and 2015, which enrolled 2621 patients. Patients receiving VDRAs had lower eGFR (weighted mean difference WMD -1.29 mL/min /1.73 m2, 95% CI -2.42 to -0.17 and elevated serum creatinine (WMD 7.03 μmol/L, 95% CI 0.61 to 13.46 in sensitivity analysis excluding studies with dropout rate more than 30%. Subgroup analysis of the 5 studies that not use SCr-based measures did not indicated lower GFR in the VDRAs group(WMD -0.97 mL/min/1.73 m2, 95% CI -4.85 to 2.92. Compared with control groups, there was no difference in all-cause mortality (relative risk RR 1.41, 95% CI 0.58 to 3.80, cardiovascular disease (RR 0.84, 95% CI 0.42 to 1.71, and severe adverse events (RR 1.15, 95% CI 0.75 to 1.77 for the VDRAs groups. Episodes of hypercalcemia (RR 3.29, 95% CI 2.02 to 5.38 were more common in the VDRAs group than in the control group.Administration of VDRAs increased serum creatinine levels. Subgroup analysis of studies that did not use SCr-based measures did not indicate a lower GFR in the VDRA group. Future studies with non-SCr-based measures are needed to assess whether the mild elevations of serum creatinine are of clinical significance.

  14. Utilization of small changes in serum creatinine with clinical risk factors to assess the risk of AKI in critically lll adults.

    Science.gov (United States)

    Cruz, Dinna N; Ferrer-Nadal, Asunción; Piccinni, Pasquale; Goldstein, Stuart L; Chawla, Lakhmir S; Alessandri, Elisa; Belluomo Anello, Clara; Bohannon, Will; Bove, Tiziana; Brienza, Nicola; Carlini, Mauro; Forfori, Francesco; Garzotto, Francesco; Gramaticopolo, Silvia; Iannuzzi, Michele; Montini, Luca; Pelaia, Paolo; Ronco, Claudio

    2014-04-01

    Disease biomarkers require appropriate clinical context to be used effectively. Combining clinical risk factors, in addition to small changes in serum creatinine, has been proposed to improve the assessment of AKI. This notion was developed in order to identify the risk of AKI early in a patient's clinical course. We set out to assess the performance of this combination approach. A secondary analysis of data from a prospective multicenter intensive care unit cohort study (September 2009 to April 2010) was performed. Patients at high risk using this combination approach were defined as an early increase in serum creatinine of 0.1-0.4 mg/dl, depending on number of clinical factors predisposing to AKI. AKI was defined and staged using the Acute Kidney Injury Network criteria. The primary outcome was evolution to severe AKI (Acute Kidney Injury Network stages 2 and 3) within 7 days in the intensive care unit. Of 506 patients, 214 (42.2%) patients had early creatinine elevation and were deemed at high risk for AKI. This group was more likely to subsequently develop the primary endpoint (16.4% versus 1.0% [not at high risk], Pcreatinine, and hazard tier for AKI, early creatinine elevation remained an independent predictor for severe AKI (adjusted relative risk, 12.86; 95% confidence interval, 3.52 to 46.97). Addition of early creatinine elevation to the best clinical model improved prediction of the primary outcome (area under the receiver operating characteristic curve increased from 0.75 to 0.83, Phigh AKI risk, based on the combination of clinical factors and early creatinine elevation, are significantly more likely to develop severe AKI. As initially hypothesized, the high-risk combination group methodology can be used to identify patients at low risk for severe AKI in whom AKI biomarker testing may be expected to have low yield. The high risk combination group methodology could potentially allow clinicians to optimize biomarker use.

  15. Comparison of Glomerular Filtration Rate Estimation from Serum Creatinine and Cystatin C in HNF1A-MODY and Other Types of Diabetes.

    Science.gov (United States)

    Szopa, Magdalena; Kapusta, Maria; Matejko, Bartlomiej; Klupa, Tomasz; Koblik, Teresa; Kiec-Wilk, Beata; Borowiec, Maciej; Malecki, Maciej T

    2015-01-01

    We previously showed that in HNF1A-MODY the cystatin C-based glomerular filtration rate (GFR) estimate is higher than the creatinine-based estimate. Currently, we aimed to replicate this finding and verify its clinical significance. The study included 72 patients with HNF1A-MODY, 72 with GCK-MODY, 53 with type 1 diabetes (T1DM), 70 with type 2 diabetes (T2DM), and 65 controls. Serum creatinine and cystatin C levels were measured. GFR was calculated from creatinine and cystatin C using the CKD-EPI creatinine equation (eGRF-cr) and CKD-EPI cystatin C equation (eGFR-cys), respectively. Cystatin C levels were lower (p MODY, GCK-MODY, and the controls (p = 0.004; p = 0.003; p MODY patients are higher compared to eGFR-cr. Some other differences were also described in diabetic groups. However, none of them appears to be clinically relevant.

  16. Urine creatinine in treatment-naïve HIV subjects in eastern Nigeria.

    Science.gov (United States)

    Anyabolu, Ernest Ndukaife

    2016-01-01

    Human immunodeficiency virus (HIV) infection is a global healthcare problem. Some diseases and physiological states may be altered in HIV-infected individuals. Our objective was to evaluate urine creatinine and factors that influence urine creatinine in treatment-naïve HIV subjects in Nigeria. This was a cross-sectional study involving treatment-naïve HIV subjects in a tertiary hospital in Nigeria. Creatinine in spot and 24-hour urine samples and other relevant investigations were performed. Low urine creatinine or dilute urine was defined as 24-hour urine creatinine (24HUCr) creatinine as 24HUCr 300-3000mg and high urine creatinine or concentrated urine as 24HUCr>3000mg.Theassociation of low urine creatinine and high urine creatinine with potential risk factors was determined. The mean spot urine creatinine (SUCr) of the treatment-naïve HIV subjects was 137.21± 98.47(mg/dl), minimum value 13.3mg/dl, maximum value 533.3mg/dl and range of values 520.0mg/dl. The mean 24HUCr was 1507±781mg, minimum value 206mg, maximum value 4849mg and range of values 4643mg. Twenty four-hour urine creatinine3000mg in 24(6.4%) subjects. There was significant association between 24HUCr and serum low density lipoprotein cholesterol (LDL),serum high density lipoprotein cholesterol (HDL). There was high correlation between 24HUCr>3000mg and 24-hour urine osmolality (24HUOsm) (r=0.95), body mass index (BMI) (r=0.74), CD4 cells count (r=-0.71), serum HDL (r=-0.73). The prevalence of dilute urine and concentrated urine was low. Twenty-four hour urine osmolality. BMI, CD4 cells count and HDL were strong correlates of high urine creatinine. Lipid abnormalities were common in treatment-naïve HIV subjects with high urine creatinine. There is need for clinicians to routinely conduct urine creatinine and further search for abnormalities of serum lipids, weight changes, depressed immunity and anemia in HIV subjects with dilute or concentrated urine in the early stages of the infection.

  17. Mechanisms Underpinning Increased Plasma Creatinine Levels in Patients Receiving Vemurafenib for Advanced Melanoma

    Science.gov (United States)

    Hurabielle, Charlotte; Pillebout, Evangéline; Stehlé, Thomas; Pagès, Cécile; Roux, Jennifer; Schneider, Pierre; Chevret, Sylvie; Chaffaut, Cendrine; Boutten, Anne; Mourah, Samia; Basset-Seguin, Nicole; Vidal-Petiot, Emmanuelle; Lebbé, Céleste; Flamant, Martin

    2016-01-01

    Context Serum creatinine has been reported to increase in patients receiving Vemurafenib, yet neither the prevalence nor the mechanism of this adverse event are known. Objective We aimed to evaluate the frequency and the mechanisms of increases in plasma creatinine level in patients receiving Vemurafenib for advanced melanoma. Methods We performed a retrospective monocentric study including consecutive patients treated with Vemurafenib for an advanced melanoma. We collected clinical and biological data concerning renal function before introduction of Vemurafenib and in the course of monthly follow-up visits from March 2013 to December 2014. Cystatin C-derived glomerular filtration rate was evaluated before and after Vemurafenib initiation, as increase in serum cystatin C is specific to a decrease in the glomerular filtration rate. We also performed thorough renal explorations in 3 patients, with measurement of tubular secretion of creatinine before and after Vemurafenib initiation and a renal biopsy in 2 patients. Results 70 patients were included: 97% of them displayed an immediate, and thereafter stable, increase in creatinine (+22.8%) after Vemurafenib initiation. In 44/52 patients in whom Vemurafenib was discontinued, creatinine levels returned to baseline. Serum cystatin C increased, although proportionally less than serum creatinine, showing that creatinine increase under vemurafenib was indeed partly due to a renal function impairment. In addition, renal explorations demonstrated that Vemurafenib induced an inhibition of creatinine tubular secretion. Conclusion Thus, Vemurafenib induces a dual mechanism of increase in plasma creatinine with both an inhibition of creatinine tubular secretion and slight renal function impairment. However, this side effect is mostly reversible when Vemurafenib is discontinued, and should not lead physicians to discontinue the treatment if it is effective. PMID:26930506

  18. Clinical value of renal injury biomarkers in diagnosis of chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Cheng-lu ZHANG

    2011-12-01

    Full Text Available Objective To investigate the levels of renal injury biomarkers in patients with chronic kidney disease(CKD and evaluate their clinical significances in diagnosis of CKD.Methods A total of 66 subjects(37 patients with CKD and 29 healthy individuals were involved in this study.Serum blood urea nitrogen(SBUN was determined by Glutamate dehydrogenase method;serum creatinine(SCr and urinary creatinine(UCr were detected by sarcosine oxidase method;serum uric acid(SUA was measured by uricase colorimetry;serum cystatin C(Cys C and urinary microalbumin(UmAlbwere analyzed by immunological transmission turbidimetry;urinary protein(U-PROwas measured by Coomassies Brilliant Blue(CBB assay.The UmAlb and U-PRO levels were expressed in units of mg/mmolUCr.Results The results of independent samples t test indicated that significant differences were found in SBUN,SCr,SUA,Cys C,UmAlb and U-PRO(P < 0.05 between patient group and healthy control group.The evaluation of diagnostic effects showed that the areas under the curve at ROC plot for SBUN,SCr,SUA,Cys C,UmAlb and U-PRO were 0.907,0.912,0.742,0.982,0.984 and 0.991,respectively.Conclusions U-PRO,UmAlb and Cys C are ideal biomarkers,SCr and SBUN come next,SUA is the weakest when the above biomarkers are applied to evaluate the renal injury and its severity of the patients with CKD.

  19. Validation of the salivary urea and creatinine tests as screening methods of chronic kidney disease in Vietnamese patients.

    Science.gov (United States)

    Pham, Thuy Anh Vu

    2017-11-01

    The aims of this case control study were to correlate the serum and salivary urea as well as creatinine levels; and to evaluate salivary urea and creatinine as noninvasive alternatives to serum for creatinine estimation in chronic kidney disease (CKD) patients. Blood and saliva samples were collected from 112 CKD patients and 108 subjects without CKD for quantitative analysis of urea and creatinine. Spearman's correlation coefficients between salivary and serum urea as well as creatinine were obtained. Receiver operating characteristic analysis was done to assess the diagnostic tests of salivary urea and creatinine. Cut-off values were determined based on the best trade-off between the sensitivity and specificity for both salivary urea and creatinine. Salivary urea and creatinine concentrations were significantly higher in CKD patients than those in control subjects; and increased by the stages of the severity of the disease. The positive correlation was significantly found between salivary and serum creatinine (r  =  0.90) and between salivary and serum urea (r  =  0.73). Area under the curve for salivary urea was 0.76 and a cut-off value of 14.25 mmol/L gave a sensitivity of 82.9% and specificity of 57.8%. Area under the curve for salivary creatinine was 0.92 and a cut-off value of 0.24 mg/dL gave a sensitivity of 86.5% and specificity of 87.2%. Both salivary urea and creatinine have a high capacity for serum creatinine estimation. Salivary urea and creatinine tests can be used as low-cost, easily accessible and noninvasive tools for screening, diagnosing, monitoring treatment outcomes and ascertaining prognosis of chronic kidney disease.

  20. Renal function in the fetus and neonate - the creatinine enigma.

    Science.gov (United States)

    Kastl, Justin T

    2017-04-01

    The use of serum creatinine levels to estimate glomerular function in infants is admittedly fraught with inherent inaccuracies which are both physiological and methodological in nature. This characteristic can understandably reduce the neonatal clinician's confidence in the ability of serum creatinine levels to provide useful information relevant to their patients' medical care. The aim of this review is to provide further insight into the peculiarities of serum creatinine trends in both premature and term infants with special focus on the maturational and developmental changes occurring in the kidney during this crucial time-period. Though newer markers of glomerular function are gaining increasing traction in the clinical realm, the most prominent of which is currently cystatin C, creatinine nonetheless remains an important player in the scientific evolution of glomerular filtration rate (GFR) estimation. Not only do its limitations provide a level of distinction for newer markers of GFR, but its advantages persist in refining the precision of newer GFR formulae which incorporate multiple patient characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Relevance of Changes in Serum Creatinine During a Heart Failure Trial of Decongestive Strategies: Insights From the DOSE Trial.

    Science.gov (United States)

    Brisco, Meredith A; Zile, Michael R; Hanberg, Jennifer S; Wilson, F Perry; Parikh, Chirag R; Coca, Steven G; Tang, W H Wilson; Testani, Jeffrey M

    2016-10-01

    Worsening renal function (WRF) is a common endpoint in decompensated heart failure clinical trials because of associations between WRF and adverse outcomes. However, WRF has not universally been identified as a poor prognostic sign, challenging the validity of WRF as a surrogate endpoint. Our aim was to describe the associations between changes in creatinine and adverse outcomes in a clinical trial of decongestive therapies. We investigated the association between changes in creatinine and the composite endpoint of death, rehospitalization or emergency room visit within 60 days in 301 patients in the Diuretic Optimization Strategies Evaluation (DOSE) trial. WRF was defined as an increase in creatinine >0.3 mg/dL and improvement in renal function (IRF) as a decrease >0.3 mg/dL. When examining linear changes in creatinine from baseline to 72 hours (the coprimary endpoint of DOSE), increasing creatinine was associated with lower risk for the composite outcome (HR = 0.81 per 0.3 mg/dL increase, 95% CI 0.67-0.98, P = .026). Compared with patients with stable renal function (n = 219), WRF (n = 54) was not associated with the composite endpoint (HR = 1.17, 95% CI = 0.77-1.78, P = .47). However, compared with stable renal function, there was a strong relationship between IRF (n = 28) and the composite endpoint (HR = 2.52, 95% CI = 1.57-4.03, P creatinine, was paradoxically associated with improved outcomes. This was driven by absence of risk attributable to WRF and a strong risk associated with IRF. These results argue against using changes in serum creatinine as a surrogate endpoint in trials of decongestive strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Labeling of creatinine with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Yurt Lambrecht, F. [Ege Univ., Bornova, Izmir (Turkey). Dept. of Nuclear Applications, Inst. of Nuclear Sciences; Durkan, K. [Dokuz Eylul Univ., Buca, Izmir (Turkey). Chemistry Technicianship Program, Izmir Vocational School; Soylu, A. [Dokuz Eylul Univ., Narlidere, Izmir (Turkey). Dept. of Pediatrics, Medical Faculty

    2004-07-01

    Creatinine is a clinically important index of renal glomerular filtration rate. Urine creatinine levels can be used as a screening test to evaluate kidney function or can be part of the creatinine clearance test. In case of kidney dysfunction or muscle disorders the creatinine concentration in serum/plasma may rise to a higher value than in healthy body. Technetium- 99m has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. {sup 99m}Tc is utilized to label molecules and cells, used as radiopharmaceuticals, and also to label biological species. It presents many desirable characteristics. SnCl{sub 2} method is frequently used as a reducing agent in the {sup 99m}Tc- labeling process. Creatinine metabolism might be investigated by using labeled {sup 99m}Tc- creatinine in healthy or uremic rats. (orig.)

  3. Re-recognition of Age-dependent Reference Range for the Serum Creatinine Level in Teenagers - A Case of Slowly Progressive Tubulointerstitial Nephritis which Occurred in an Adolescent.

    Science.gov (United States)

    Ono, Hiroyuki; Nagai, Kojiro; Shibata, Eriko; Matsuura, Motokazu; Kishi, Seiji; Inagaki, Taizo; Minato, Masanori; Yoshimoto, Sakiya; Ueda, Sayo; Obata, Fumiaki; Nishimura, Kenji; Tamaki, Masanori; Kishi, Fumi; Murakami, Taichi; Abe, Hideharu; Kinoshita, Yukiko; Urushihara, Maki; Kagami, Shoji; Doi, Toshio

    2017-08-15

    For the first time, a 15-year-old boy was found to have a slight degree of proteinuria and microscopic hematuria during annual school urinalysis screening. His kidney function had already severely deteriorated. A kidney biopsy revealed tubulointerstitial nephritis (TIN) with diffuse inflammatory cell infiltration. His medical records showed his serum creatinine level to be 0.98 mg/dL two years ago, which was abnormally high considering his age. Although the etiology of slowly progressive TIN was unclear, glucocorticoid and immunosuppressant therapy improved his kidney function. This case report suggests that all doctors should recognize the reference range for the serum creatinine level in teenagers.

  4. Reference Ranges of Serum Blood Urea Nitrogen, Creatinine Concentration and Ultrasonographic Measurement of the Kidneys in Term Healthy Newborns in the Neonatal Period

    Directory of Open Access Journals (Sweden)

    Şebnem Kader

    2017-12-01

    Full Text Available Objective: Acute kidney injury is an important problem in neonates. We conducted a cross-sectional prospective study to determine normal serum blood urea nitrogen, creatinine reference ranges and ranges of ultrasonographic measurement of kidneys in healthy term newborns. Study Design: Blood samples were collected from total 357 healthy newborns at birth (n=45, 1st (n=30, 3rd (n=61, 7th (n=34, 10th (n=132, 14th (n=36, and 28th (n=19 days of life. Renal ultrasonographic was performed by the same two radiologists on 81 newborns aged 10 days. Results: Serum blood urea nitrogen and creatinine concentrations have reached to the highest level at the first day of life and have returned to cord level at the third day of life. There were gradually decrease in serum blood urea nitrogen and creatinine levels after the first day of life. There were significant difference in both right and left renal length, width, and volumes in terms of gender and these parameters were statistically higher in boys than girls (p<0.05. Birth weight of the boys (3548±539g was statistically higher than girls (3307±405 g (p=0.028. There was a positive correlation between birth weight and right (r=0.38, p=0.000 and left kidney volumes (r=0.44, p=0.000. Conclusion: Our findings showed that measured blood urea nitrogen and creatinine levels changed in accordance with postnatal days and there was a positive correlation between kidney volume and birth weight of newborns. We concluded that these findings are important for evaluation of acute kidney injury and for screening of for urinary tract anomalies in neonates

  5. Comparing cystatin C and creatinine in the diagnosis of pediatric acute renal allograft dysfunction

    NARCIS (Netherlands)

    Slort, Pauline R.; Ozden, Nergiz; Pape, Lars; Offner, Gisela; Tromp, Wilma F.; Wilhelm, Abraham J.; Bokenkamp, Arend

    2012-01-01

    Allograft function following renal transplantation is commonly monitored using serum creatinine. Multiple cross-sectional studies have shown that serum cystatin C is superior to creatinine for detection of mild to moderate chronic kidney dysfunction. Recent data in adults indicate that cystatin C

  6. Glomerular filtration rate equations overestimate creatinine clearance in older individuals enrolled in the Baltimore Longitudinal Study on Aging: impact on renal drug dosing.

    Science.gov (United States)

    Dowling, Thomas C; Wang, En-Shih; Ferrucci, Luigi; Sorkin, John D

    2013-09-01

    To evaluate the performance of kidney function estimation equations and to determine the frequency of drug dose discordance in an older population. Cross-sectional analysis of data from community-dwelling volunteers randomly selected from the Baltimore Longitudinal Study of Aging from January 1, 2005, to December 31, 2010. A total of 269 men and women with a mean ± SD age of 81 ± 6 years, mean serum creatinine concentration (Scr ) of 1.1 ± 0.4 mg/dl, and mean 24-hour measured creatinine clearance (mClcr ) of 53 ± 13 ml/minute. Kidney function was estimated by using the following equations: Cockcroft-Gault (CG), Modification of Diet in Renal Disease (MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). The performance of each equation was assessed by measuring bias and precision relative to mClcr . Dose calculation errors (discordance) were determined for 10 drugs requiring renal dosage adjustments to avoid toxicity when compared with the dosages approved by the Food and Drug Administration. The CG equation was the least biased estimate of mClcr . The MDRD and CKD-EPI equations were significantly positively biased compared with CG (mean ± SD 34 ± 20% and 22 ± 15%, respectively, prenal impairment. Thus equations estimating glomerular filtration rate should not be substituted in place of the CG equation in older adults for the purpose of renal dosage adjustments. In addition, the common practice of rounding or replacing low Scr values with an arbitrary value of 1.0 mg/dl for use in the CG equation should be avoided. Additional studies that evaluate alternative eGFR equations in the older populations that incorporate pharmacokinetic and pharmacodynamic outcomes measures are needed. © 2013 Pharmacotherapy Publications, Inc.

  7. Final report on CCQM-K80: Comparison of value-assigned CRMs and PT materials: Creatinine in human serum

    Science.gov (United States)

    Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    The 2009 CCQM-K80 'Comparison of value-assigned CRMs and PT materials: creatinine in human serum' is the first in a series of key comparisons directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes. CCQM-K80 compared the assigned serum creatinine values of certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Six NMIs submitted 17 CRM materials for evaluation, all intended for sale to customers. These materials represent nearly all of the higher-order CRMs then available for this clinically important measurand. The certified creatinine mass fraction in the materials ranged from 3 mg/kg to 57 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analyst using isotope dilution liquid chromatography-mass spectrometry. The instrumental repeatability imprecision, expressed as a percent relative standard deviation, was 1.2%. Given the number of materials and the time required for each analysis, the measurements were made in two measurement campaigns ('runs'). In both campaigns, replicate analyses (two injections of one preparation separated in time) were made on each of two or three independently prepared aliquots from one randomly selected unit of each of the 17 materials. The mean value, between-campaign, between-aliquot and between-replicate variance components, standard uncertainty of the mean value, and the number of degrees of freedom associated with the standard uncertainty were estimated using a linear mixed model. Since several of the uncertainties estimated using this traditional frequentist approach were associated with a single degree of freedom, Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals, U95. Uncertainty-weighted generalized distance

  8. [Concordance of glomerular filtration rate with creatinine clearance in 24-hour urine and Schwartz and Schwartz updated].

    Science.gov (United States)

    Salazar-Gutiérrez, María Luisa; Ochoa-Ponce, Cristina; Lona-Reyes, Juan Carlos; Gutiérrez-Íñiguez, Sara Ivonne

    Reference methods for the quantification of the glomerular filtration rate (GFR) are difficult to use in clinical practice; formulas for evaluating GFR based on serum creatinine (SCr) and/or creatinine clearance are used. The aim of this study was to quantify the correlation and concordance of GFR with creatinine clearance in 24-hour urine (GFR24) and Schwartz and Schwartz updated formulas. Cross-sectional study involving healthy pediatric patients and with chronic kidney disease (CKD) from 5 to 16.9 years. Linear correlation between GFR 24 and two formulas was evaluated with the Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC). We studied 134 patients, of which 59.7% were male. Mean age was 10.8 years. The average GFR24 was 140.34ml/min/1.73m 2 ; 34.3% (n=46) had GFR <90ml/min/1.73m 2 . Moderate linear correlation between GFR24 and Schwartz (r= 0.63) and Schwartz updated (r= 0.65) formulas was observed. There was good concordance between the GFR24 and Schwartz (ICC= 0.77) and updated Schwartz (ICC= 0.77) formulas. Schwartz classical formula in patients with GFR24 ≥ 90ml/min/1.73m 2 estimated higher values, while Schwartz updated underestimated values. There is moderate correlation and good concordance between the GFR24 and Schwartz and Schwartz updated formulas. The concordance was better in patients with obesity and lower in women, patients with hyperfiltration and normal weight. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  9. Serum creatinine and creatinine clearance for predicting plasma methotrexate concentrations after high-dose methotrexate chemotherapy for the treatment for childhood lymphoblastic malignancies.

    Science.gov (United States)

    Xu, Wei-qun; Zhang, Ling-yan; Chen, Xue-ying; Pan, Bin-hua; Mao, Jun-qing; Song, Hua; Li, Jing-yuang; Tang, Yong-min

    2014-01-01

    Monitoring of plasma methotrexate (MTX) concentrations allows for therapeutic adjustments in treating childhood acute lymphoblastic leukemia (ALL) or non-Hodgkin lymphoma (NHL) with high-dose MTX (HDMTX). We tested the hypothesis that assessment of creatinine clearance (CrCl) and/or serum Cr may be a suitable means of monitoring plasma MTX concentrations. All children in the study had ALL or NHL, were in complete remission, and received HDMTX (3 or 5 g/m(2))+leucovorin. Plasma MTX concentrations were measured at 24, 48, and 96 h. CrCl was determined at 24 and 48 h. Correlations between 24- and 48-h plasma MTX concentrations and CrCl and serum Cr concentrations were determined. CrCl and serum Cr concentrations were compared over time between children who had delayed and non-delayed MTX elimination. A total of 105 children were included. There were significant negative correlations between CrCl at 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were significant positive correlations between serum Cr concentrations at both 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were 88 (30.2 %) instances of elimination delay. Children with elimination delay had significantly lower CrCl and higher Cr concentrations at 24 and 48 h compared with children without elimination delay (all p < 0.05). Our findings suggest that, with further refinement, assessment of renal function may be a useful means of monitoring plasma MTX concentrations during HDMTX for ALL and NHL.

  10. SCR in biomass and waste fuelled plants. Benchmarking of Swedish and European plants; SCR i biobraensle- och avfallseldade anlaeggningar. Erfarenheter fraan svenska och europeiska anlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmidt, Barbara; Olsson, Henrik; Lindstroem, Erica

    2010-11-15

    In this report the state-of-art of SCR technology in biomass and waste fired plants is investigated. The aim of the investigation is to answer the question why new Swedish biomass combustion and co-combustion plants often prefer SNCR technology, whilst European waste combustion plants often choose SCR technology. In the report positives and negatives of various types of SCR installations are discussed, high-dust versus tail-end, 'normal' SCR versus low-temperature SCR, etc. Experiences, e g catalyst lifetime, deactivation and maintenance requirement, are discussed. The investigation is based partly on literature, but mainly on interviews with plant owners and with suppliers of SCR installations. The interviewed suppliers are mentioned in the reference list and the interviewed plant owners are mentioned in appendix A and B. The experiences from the Swedish and European plants are quite similar. Tail-end SCR is often operated without serious problems in both biomass and waste fuelled plants. The catalyst lifetimes are as long or even longer than for coal fired plants with high-dust SCR. In waste incineration plants high-dust SCR causes big problems and these plants are almost always equipped with tail-end SCR. In co-combustion boilers, where coal and biomass is co-combusted, high-dust SCR is more common, especially if the boilers were originally coal fired. In plants with both SNCR and high-dust SCR, i.e. slip-SCR, the SCR installation is considered to be much less of a problem. Although the activity loss of the catalyst is as quick as in conventional high-dust SCR, the catalyst can be changed less often. This is due to the fact that installed slip-SCR catalysts often are as large as conventional SCR catalysts, although less NO{sub x} reduction is required after the initial SNCR step. Thus, the catalyst lifetime is prolonged.

  11. The SS-SCR Scheme for Dynamic Spectrum Access

    Directory of Open Access Journals (Sweden)

    Vinay Thumar

    2012-01-01

    Full Text Available We integrate the two models of Cognitive Radio (CR, namely, the conventional Sense-and-Scavenge (SS Model and Symbiotic Cooperative Relaying (SCR. The resultant scheme, called SS-SCR, improves the efficiency of spectrum usage and reliability of the transmission links. SS-SCR is enabled by a suitable cross-layer optimization problem in a multihop multichannel CR network. Its performance is compared for different PU activity patterns with those schemes which consider SS and SCR separately and perform disjoint resource allocation. Simulation results depict the effectiveness of the proposed SS-SCR scheme. We also indicate the usefulness of cloud computing for a practical deployment of the scheme.

  12. Effect of creatinine assay calibration on glomerular filtration rate prediction by MDRD equation

    Directory of Open Access Journals (Sweden)

    Débora Spessatto

    2009-01-01

    Full Text Available Background: The evaluation of renal function should be performed with glomerular filtration rate (GFR estimation employing the Modification of Diet in Renal Disease (MDRD study equation, which includes age, gender, ethnicity and serum creatinine. However, creatinine methods require traceability with standardized methods. Objective: To analyse the impact of creatinine calibration on MDRD calculated GFR. Methods: 140 samples of plasma with creatinine values <2,0 mg/dl were analysed by Jaffé’s reaction with Creatinina Modular P (Roche ®; method A; reference and Creatinina Advia 1650 (Bayer ®; method B; non-standardized. The results with the different methods were compared and aligned with standardized method through a conversion formula. MDRD GFR was estimated. Results: Values were higher for method B (1.03 ± 0.29 vs. 0.86 ± 0.32 mg/dl, P<0.001. This difference declined when methods were aligned with the equation y=1.07x -0.249, and the aligned values were 0,9 ± 0,31 mg/dl. Non-traceable creatinine methods misclassificaed chronic kidney disease in 10% more (false positive. This disagreement disappeared after the regression alignment. Conclusion: Creatinine method calibration has a large impact over the final results of serum creatinine and GFR. The alignment of the non-standardized results through conversion formulas is a reasonable alternative to harmonize serum creatinine results while waiting for the full implementation of international  standardization programs.

  13. The impact of oat (Avena sativa) consumption on biomarkers of renal function in patients with chronic kidney disease: A parallel randomized clinical trial.

    Science.gov (United States)

    Rouhani, Mohammad Hossein; Mortazavi Najafabadi, Mojgan; Surkan, Pamela J; Esmaillzadeh, Ahmad; Feizi, Awat; Azadbakht, Leila

    2018-02-01

    Animal studies report that oat (Avena sativa L) intake has favorable effects on kidney function. However, the effects of oat consumption have not been assessed in humans. The aim of this study was to examine the impact of oat intake on biomarkers of renal function in patients with chronic kidney disease (CKD). Fifty-two patients with CKD were randomly assigned to a control group (recommended to reduce intake of dietary protein, phosphorus, sodium and potassium) or an oat consumption group (given nutritional recommendations for controls +50 g/day oats). Blood urea nitrogen (BUN), serum creatinine (SCr), urine creatinine, serum albumin, serum potassium, parathyroid hormone (PTH), serum klotho and urine protein concentration were measured at baseline and after an eight-week intervention. Creatinine clearance was calculated using urine creatinine concentration. Within group analysis showed a significant increase in BUN (P = 0.02) and serum potassium (P = 0.01) and a marginally significant increment in SCr (P = 0.08) among controls. However, changes in the oat group were not significant. In a multivariate adjusted model, we observed a significant difference in change of serum potassium (-0.03 mEq/L for oat group and 0.13 mEq/L for control group; P = 0.01) and a marginally significant difference in change of serum albumin (0.01 g/dl for oat group and -0.08 for control group; P = 0.08) between the two groups. There was no change in PTH concentration. Intake of oats may have a beneficial effect on serum albumin and serum potassium in patients with CKD. Present study registered under IRCT.ir identifier no. IRCT2015050414551N2. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  14. A New Equation to Estimate Muscle Mass from Creatinine and Cystatin C.

    Directory of Open Access Journals (Sweden)

    Sun-wook Kim

    Full Text Available With evaluation for physical performance, measuring muscle mass is an important step in detecting sarcopenia. However, there are no methods to estimate muscle mass from blood sampling.To develop a new equation to estimate total-body muscle mass with serum creatinine and cystatin C level, we designed a cross-sectional study with separate derivation and validation cohorts. Total body muscle mass and fat mass were measured using dual-energy x-ray absorptiometry (DXA in 214 adults aged 25 to 84 years who underwent physical checkups from 2010 to 2013 in a single tertiary hospital. Serum creatinine and cystatin C levels were also examined.Serum creatinine was correlated with muscle mass (P < .001, and serum cystatin C was correlated with body fat mass (P < .001 after adjusting glomerular filtration rate (GFR. After eliminating GFR, an equation to estimate total-body muscle mass was generated and coefficients were calculated in the derivation cohort. There was an agreement between muscle mass calculated by the novel equation and measured by DXA in both the derivation and validation cohort (P < .001, adjusted R2 = 0.829, β = 0.95, P < .001, adjusted R2 = 0.856, β = 1.03, respectively.The new equation based on serum creatinine and cystatin C levels can be used to estimate total-body muscle mass.

  15. Evaluation of the first SCR-plants in Sweden; Utvaerdering av de foersta SCR-anlaeggningarna i Sverige

    Energy Technology Data Exchange (ETDEWEB)

    Hanell, B [Vattenfall AB, Stockholm (Sweden); and others

    1996-05-01

    This report presents operational experience of SCR systems at five power plants in Sweden; the diesel cogeneration plants in Linkoeping, Oskarshamn, Skultuna and Visby and the coal fired power plant in Vaesteraas. The experience represents the first years of operation of the SCR systems. The SCR-systems involved in this project achieve the following: * Uneven flue gas flow and concentration of ammonia and NO{sub x} through the SCR reactor results in lower efficiency. Hence it is important to achieve a thorough mixing of the ammonia in the flue gas in order to achieve high NO{sub x} reduction efficiencies, * Inferior control systems can cause unnecessary ammonia slip, * The diesel plants with an operating time of a couple of thousand hours have had major problems with deposits on the catalyst surface, * Guarantees regarding the lifetime of the catalyst are important. At commissioning the catalyst has to be over-dimensioned since the system has to reach the guaranteed emissions during the whole guarantee period, * There should be enough space in the reactor to install additional catalyst layers. This project verifies that additional layers need to be installed at later stages, * The mechanical construction of the SCR-reactor is important. The efficiency decreases when there is a leakage of flue gases past the reactor, * No considerable amounts of N{sub 2}O are generated by the catalyst. 21 refs, 27 figs, 47 tabs

  16. Influence of hydrogen treatment on SCR catalysts

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes

    stream, i.e. by in situ treatment of the Pt-catalyst by reductive H2-gas. However, the introduction of H2 gas in the gas stream could also affect other units in the tail pipe gas cleaning system. Of special interest in this study is the effect of hydrogen gas on the performance of the selective catalytic...... reduction (SCR) process, i.e. the catalytic removal of NOx from the flue gas. A series of experiments was conducted to reveal the impact on the NO SCR activity of a industrial DeNOX catalyst (3%V2O5-7%WO3/TiO2) by treatment of H2. Standard conditions were treatment of the SCR catalyst for 60 min with three...... different concentrations of H2 (0-2%) in a 8% O2/N2 mixture, where the SCR activity was measured before and after the hydrogen treatment. The results show that the activity of the SCR catalyst is only negligible affected during exposure to the H2/O2 gas and in all cases it returned reversibly to the initial...

  17. Impact on creatinine renal clearance by the interplay of multiple renal transporters: a case study with INCB039110.

    Science.gov (United States)

    Zhang, Yan; Warren, Mark S; Zhang, Xuexiang; Diamond, Sharon; Williams, Bill; Punwani, Naresh; Huang, Jane; Huang, Yong; Yeleswaram, Swamy

    2015-04-01

    Serum creatinine is commonly used as a marker of renal function, but increases in serum creatinine might not represent changes in glomerular filtration rate (GFR). INCB039110 (2-(3-(4-(7H-pyrrolo[2,3-day]pyrimidin-4-yl)-1H-pyrazol-1-yl)-1-(1-(3-fluoro-2-(trifluoromethyl)isonicotinoyl)piperidin-4-yl)azetidin-3-yl)acetonitrile) is an inhibitor of the Janus kinases (JAKs) with selectivity for JAK1. In a phase 1 study, a modest and reversible increase in serum creatinine was observed after treatment with INCB039110. However, a dedicated renal function study with INCB039110, assessed by iohexol plasma clearance, conducted in healthy volunteers indicated no change in GFR. In vitro studies were therefore conducted to investigate the interaction of INCB039110 with five transporters that are likely involved in the renal clearance of creatinine. Cell systems expressing individual or multiple transporters were used, including a novel quintuple-transporter model OAT2/OCT2/OCT3/MATE1/MATE2-K. INCB039110 potently inhibited OCT2-mediated uptake of creatinine as well as MATE1-/MATE2-K-mediated efflux of creatinine. Given the interactions of INCB039110 with multiple transporters affecting creatinine uptake and efflux, an integrated system expressing all five transporters was sought; in that system, INCB039110 caused a dose-dependent decrease in transcellular transport of creatinine with weaker net inhibition compared with the effects on individual transporters. In summary, a molecular mechanism for the increase in serum creatinine by INCB039110 has been established. These studies also underline the limitations of using serum creatinine as a marker of renal function. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.

  18. Creatinine Change on Vasoconstrictors as Mortality Surrogate in Hepatorenal Syndrome: Systematic Review & Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Justin M Belcher

    Full Text Available Hepatorenal syndrome is a severe complication of cirrhosis and associates with significant mortality. Vasoconstrictor medications improve renal function in patients with hepatorenal syndrome. However, it is unclear to what extent changes in serum creatinine during treatment may act as a surrogate for changes in mortality. We have performed a meta-analysis of randomized trials of vasoconstrictors assessing the association between changes in serum creatinine, taken as a continuous variable, and mortality, both while on treatment and during the follow-up period for survivors.The electronic databases of PubMed, Web of Science and Embase were searched for randomized trials evaluating the efficacy of vasoconstrictor therapy for treatment of HRS type 1 or 2. The relative risk (RR for mortality was calculated against delta creatinine. The proportion of treatment effect explained (PTE was calculated for delta creatinine.Seven trials enrolling 345 patients were included. The correlation between delta creatinine and ln (RR was moderately good (R2 = 0.61. The intercept and parameter estimate indicated a fall in creatinine while on treatment of 1 mg/dL resulted in a 27% reduction in RR for mortality compared to the control arm. In patients surviving the treatment period, a fall in creatinine while on treatment of 1 mg/dL resulted in a 16% reduction in RR for post-treatment mortality during follow-up. The PTE of delta creatinine for overall mortality was 0.91 and 0.26 for post-treatment mortality.Changes in serum creatinine in response to vasoconstrictor therapy appear to be a valid surrogate for mortality, even in the period following the completion of treatment.

  19. Creatinine Change on Vasoconstrictors as Mortality Surrogate in Hepatorenal Syndrome: Systematic Review & Meta-Analysis

    Science.gov (United States)

    Belcher, Justin M.; Coca, Steven G.; Parikh, Chirag R.

    2015-01-01

    Background and Aims Hepatorenal syndrome is a severe complication of cirrhosis and associates with significant mortality. Vasoconstrictor medications improve renal function in patients with hepatorenal syndrome. However, it is unclear to what extent changes in serum creatinine during treatment may act as a surrogate for changes in mortality. We have performed a meta-analysis of randomized trials of vasoconstrictors assessing the association between changes in serum creatinine, taken as a continuous variable, and mortality, both while on treatment and during the follow-up period for survivors. Methods The electronic databases of PubMed, Web of Science and Embase were searched for randomized trials evaluating the efficacy of vasoconstrictor therapy for treatment of HRS type 1 or 2. The relative risk (RR) for mortality was calculated against delta creatinine. The proportion of treatment effect explained (PTE) was calculated for delta creatinine. Results Seven trials enrolling 345 patients were included. The correlation between delta creatinine and ln (RR) was moderately good (R2 = 0.61). The intercept and parameter estimate indicated a fall in creatinine while on treatment of 1 mg/dL resulted in a 27% reduction in RR for mortality compared to the control arm. In patients surviving the treatment period, a fall in creatinine while on treatment of 1 mg/dL resulted in a 16% reduction in RR for post-treatment mortality during follow-up. The PTE of delta creatinine for overall mortality was 0.91 and 0.26 for post-treatment mortality. Conclusions Changes in serum creatinine in response to vasoconstrictor therapy appear to be a valid surrogate for mortality, even in the period following the completion of treatment. PMID:26295585

  20. Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer.

    Science.gov (United States)

    Qin, Jia; Wang, Huiying; Rets, Anton; Harari, Saul; Alexis, Herol; Eid, Ikram; Pincus, Matthew R

    2013-11-01

    Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. We find that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer. © 2013 Wiley Periodicals, Inc.

  1. Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment

    Science.gov (United States)

    O’Brien, Katie M.; Upson, Kristen; Cook, Nancy R.; Weinberg, Clarice R.

    2015-01-01

    Background Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. Objectives We compared adjustment methods, including novel approaches, using simulated case–control data. Methods Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. Results For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. Conclusions To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals. Citation O’Brien KM, Upson K, Cook NR, Weinberg CR. 2016. Environmental chemicals in urine and blood: improving methods for creatinine and lipid adjustment. Environ Health Perspect 124:220–227; http://dx.doi.org/10.1289/ehp.1509693 PMID:26219104

  2. Elevated serum creatinine and hyponatraemia as prognostic factors in canine acute pancreatitis.

    Science.gov (United States)

    Marchetti, V; Gori, E; Lippi, I; Luchetti, E; Manca, M L; Pierini, A

    2017-11-01

    To evaluate prognostic factors for canine acute pancreatitis (AP) based on clinical and laboratory data that can be easily assessed in veterinary practice. Retrospective study between January 2010 and December 2013. The diagnosis of AP was based on clinical signs and an abnormal SNAP® cPL™ test result, concurrently with an ultrasound pattern suggestive of pancreatitis. Dogs were divided into survivors and non-survivors. We evaluated 12 clinical and laboratory parameters: respiratory rate, rectal temperature, white blood cells, haematocrit, total serum proteins, albumin, creatinine, cholesterol, total and ionised calcium, sodium and potassium. Clinical and clinicopathological data were statistically compared between survivors and non-survivors. A value of P  212 μmol/L (2.4 mg/dL) were associated significantly with poor prognosis. Azotaemia (OR 12.5; 95% confidence interval (CI) 1.32-118.48) and hyponatraemia (OR 4.9; 95% CI 1.36-17.64) were associated with increased risk of death. In dogs with AP, hyponatraemia and azotaemia seem to be significantly associated with an increased risk of death. © 2017 Australian Veterinary Association.

  3. Can preoperative serum level of creatinine predict new-onset atrial fibrillation in non-diabetic male patients undergoing open heart surgery? A retrograde view.

    Directory of Open Access Journals (Sweden)

    Seyed Jalil Mirhosseini

    2013-12-01

    Full Text Available Renal dysfunction is a risk marker in patients who candidate for coronary artery bypass graft (CABG. Renal disorder is associated with prolonged stays in intensive care unit and hospital, morbidity and mortality. Aim of this study is specific evaluation of association between preoperative creatinine (Cr with atrial fibrillation (AF after elective off-pump CABG in non-diabetic male patients with normal ejection fraction. Two hundred non-diabetic male patients with normal ejection fraction undergoing elective off pump CABG surgery enrolled in this cross-sectional study and were stratified by present or absence of postoperative atrial fibrillation: patients with postoperative new-onset atrial fibrillation (n=100 as group 1 and patients without new-onset postoperative atrial fibrillation as group 2 (n=100. Preoperative serological test of the participants, such as serum creatinine, were recorded in their medical dossiers. Data were analyzed in SPSS-16 software and tested for association between atrial fibrillation with creatinine level by using student t test, chi-square test or logistic regression. Cr level in patients with and without AF three days before surgery were 1.8±0.3 and 1.0±0.4 respectively (P value for Cr=0.00. On surgical day, mean Cr level in patients with and without AF were 1.6±0.2 and 1.1±0.5 respectively (P value for Cr = 0.00. Of the 100, male patients with postoperative AF, duration and frequency of recurrence of AF were not associated with Cr at three days before surgery and on surgical days (P>0.05. Patients with postoperative AF had unsuitable status of renal function compare to patients without AF; however, preoperative serum creatinine cannot associate with duration and frequency of recurrence of AF.

  4. Fractional excretion of beta-2-microglobulin in the urine of patients with normal or reduced renal function and hepatic coma

    DEFF Research Database (Denmark)

    Hansen, P B; Dalhoff, K; Joffe, P

    1991-01-01

    The purpose of this prospective study was to evaluate beta-2-microglobulin (beta 2m) as a differential diagnostic indicator between hepatic nephropathy (HN) and acute tubulointerstitial nephropathy (ATIN) in patients with reduced renal function and hepatic coma, and to determine whether beta 2m...... excretion could be used as a marker of renal impairment before increased serum creatinine (S-Cr) concentration or decreased creatinine clearance (Cr-Cl). Finally, the use of beta 2m as a prognostic indicator was investigated. Eighteen patients in hepatic coma grade III-IV were entered in the study and were...... to the small number of patients. FE-beta 2m could not predict the development of renal failure earlier than the increase in S-Cr or decrease in Cr-Cl. However, a few patients who survived paracetamol intoxication had increased FE-beta 2M in the beginning of the coma and normal S-Cr and Cr-Cl. Patients who died...

  5. Positive Impact of Nutritional Interventions on Serum Symmetric Dimethylarginine and Creatinine Concentrations in Client-Owned Geriatric Cats.

    Directory of Open Access Journals (Sweden)

    Jean A Hall

    Full Text Available A prospective study was conducted in client-owned geriatric cats to evaluate the short- term effects of a test food on serum symmetric dimethylarginine (SDMA and creatinine (Cr concentrations. Test food contained functional lipids (fish oil, antioxidants (vitamins C and E, L-carnitine, botanicals (vegetables, highly bioavailable protein, and amino acid supplements. Cats (n = 80 were fed either test food or owner's-choice foods (non-nutritionally controlled cohort. Cats were included based on age (≥ 9 years, indoor only, neutered, and free of chronic disease. At baseline, all cats had serum Cr concentrations within the reference interval. Renal function biomarkers and urinalysis results at baseline and after consuming test food or owner's-choice foods for 3 and 6 months were evaluated. Cats consuming test food showed significant decreases in serum Cr and BUN concentrations across time. Overall, cats consuming owner's-choice foods showed significant increases in serum SDMA concentrations at 3 and 6 months compared with baseline (P ≤ 0.05, whereas in cats consuming test food serum SDMA concentrations did not change. At baseline or during the 6-month feeding trial, 23 (28.8% cats had increased serum SDMA, but normal serum Cr consistent with IRIS Stage 1 chronic kidney disease. This included 6 cats fed test food and 17 cats fed owner's-choice foods. In the 6 cats fed test food, serum SDMA decreased in 3 cats and remained stable in 1 cat, whereas in the 17 cats fed owner's-choice foods, serum SDMA increased in 13 cats and decreased or remained stable in 4 cats. The increase in serum SDMA concentration was significant (P = 0.02 only for cats fed owner's-choice foods. These results suggest that nonazotemic cats with elevated serum SDMA (early renal insufficiency when fed a food designed to promote healthy aging are more likely to demonstrate stable renal function compared with cats fed owner's-choice foods. Cats fed owner's-choice foods were more

  6. Effect of Intravenous Administration of Contrast Media on Serum Creatinine Levels in Neonates.

    Science.gov (United States)

    Bedoya, Maria A; White, Ammie M; Edgar, J Christopher; Pradhan, Madhura; Raab, Elisabeth L; Meyer, James S

    2017-08-01

    Purpose To assess the effect of intravenous contrast media on renal function in neonates. Materials and Methods Institutional review board approval was obtained with waiver of consent. Electronic health records from January 2011 to April 2013 were reviewed retrospectively. Measures of renal function were obtained in inpatient neonates who underwent magnetic resonance (MR) imaging or computed tomography (CT) and for whom serum creatinine (Cr) levels were obtained within 72 hours before imaging and at least one time after imaging (>1 day after administration of contrast material). A total of 140 neonates who received contrast material (59 who underwent CT with iohexol or iodixanol and 81 who underwent MR imaging with gadopentetate dimeglumine) were identified. These neonates were frequency matched according to sex, gestational and postnatal age, and preimaging serum Cr levels with neonates who underwent unenhanced MR imaging or CT. Cr levels and glomerular filtration rates (GFRs) were grouped according to when they were obtained (before imaging, 1-2 days after imaging, 3-5 days after imaging, 6-9 days after imaging, 10-45 days after imaging, and more than 45 days after imaging). Serum Cr levels and GFRs for each time period were compared between groups by using hierarchic regressions or χ 2 or Fisher exact tests and with repeated-measures analysis of variance to compare groups on the rate of change in serum Cr levels and GFRs from before to after imaging. Results Cr levels decreased and GFRs increased in both groups from before to after imaging (CT group, P ≤ .01; MR imaging group, P ≤ .01). The neonates who underwent contrast material-enhanced imaging and the neonates who underwent unenhanced imaging showed similar serum Cr levels at all examined time periods. Groups also did not differ in the proportion of neonates with serum Cr levels higher than the reference range (>0.4 mg/dL) at any time point (iodine- [P > .12] or gadolinium-based [P > .13] contrast

  7. Biomarkers for acute kidney injury in decompensated cirrhosis: A Prospective Study.

    Science.gov (United States)

    Jaques, David A; Spahr, Laurent; Berra, Gregory; Poffet, Vincent; Lescuyer, Pierre; Gerstel, Eric; Garin, Nicolas; Martin, Pierre-Yves; Ponte, Belen

    2018-01-25

    Acute kidney injury (AKI) is a frequent complication in cirrhotic patients. As serum creatinine is a poor marker of renal function in this population, we aimed to study the utility of several biomarkers in this context. A prospective study was conducted in hospitalized patients with decompensated cirrhosis. Serum creatinine (SCr), Cystatin C (CystC), NGAL and urinary NGAL, KIM-1, protein, albumin and sodium were measured on three separate occasions. Renal resistive index (RRI) was obtained. We analyzed the value of these biomarkers to determine the presence of AKI, its etiology [prerenal, acute tubular necrosis (ATN), or hepatorenal (HRS)], its severity and a composite clinical outcome at 30 days (death, dialysis and intensive care admission). We included 105 patients, of which 55 had AKI. SCr, CystC, NGAL (plasma and urinary), urinary sodium and RRI at inclusion were independently associated with the presence of AKI. SCr, CystC and plasma NGAL were able to predict the subsequent development of AKI. Pre-renal state showed lower levels of SCr, NGAL (plasma and urinary) and RRI. ATN patients had high levels of NGAL (plasma and urinary) as well as urinary protein and sodium. HRS patients presented an intermediate pattern. All biomarkers paralleled the severity of AKI. SCr, CystC and plasma NGAL predicted the development of the composite clinical outcome with the same performance as the MELD score. In patients with decompensated cirrhosis, early measurement of renal biomarkers provides valuable information on AKI etiology. It could also improve AKI diagnosis and prognosis. This article is protected by copyright. All rights reserved.

  8. An evaluation of hyperkalemia and serum creatinine elevation associated with different dosage levels of outpatient trimethoprim-sulfamethoxazole with and without concomitant medications.

    Science.gov (United States)

    Gentry, Chris A; Nguyen, Ann T

    2013-12-01

    Adverse events associated with high-dose trimethoprim-sulfamethoxazole (TMP-SMX) for outpatient infections, particularly those likely caused by community-acquired methicillin-resistant Staphylococcus aureus, have not been adequately characterized. Describe hyperkalemia and acute renal injury associated with high-dose TMP-SMX. An electronic medical record database retrospective study was conducted of outpatients receiving high-dose or low-dose TMP-SMX, comparing the incidences of hyperkalemia and acute renal injury. Of 6162 patients, more developed hyperkalemia (3.06% vs 1.05%, P high-dose TMP-SMX group. Variables independently associated with hyperkalemia included age >58 years (odds ratio [OR] = 3.44; 95% CI = 1.86-7.0; P high-dose TMP-SMX prescribed (OR = 2.92; 95% CI = 1.85-4.60; P creatinine (OR = 45.1; 95% CI = 21.7-93.2; P high-dose TMP-SMX prescribed (OR = 3.70; 95% CI = 1.70-8.12; P = .0012), and baseline elevated serum creatinine (OR = 2110; 95% CI = 724-7980; P creatinine and potassium concentrations should be monitored in outpatients receiving high-dose TMP-SMX.

  9. Ammonia sensor for closed-loop SCR control

    NARCIS (Netherlands)

    Wang, D.Y.; Yao, S.; Shost, M.; Yoo, J.H.; Cabush, D.; Racine, D.; Cloudt, R.P.M.; Willems, F.P.T.

    2009-01-01

    Selective Catalytic Reduction (SCR) is the dominant solution for meeting future NOx reduction regulations for heavy-duty diesel powertrains. SCR systems benefit from closed-loop control if an appropriate exhaust gas sensor were available. An ammonia sensor has recently been developed for use as a

  10. Ammonia sensor for closed-loop SCR control

    NARCIS (Netherlands)

    Wang, D.Y.; Yao, S.; Shost, M.; Yoo, J.H.; Cabush, D.; Racine, D.; Cloudt, R.P.M.; Willems, F.P.T.

    2008-01-01

    Selective Catalytic Reduction (SCR) is the dominant solution for meeting future NOx reduction regulations for heavy-duty diesel powertrains. SCR systems benefit from closed-loop control if an appropriate exhaust gas sensor were available. An ammonia sensor has recently been developed for use as a

  11. State Estimation for the Automotive SCR Process

    DEFF Research Database (Denmark)

    Zhou, Guofeng; Huusom, Jakob Kjøbsted; Jørgensen, John Bagterp

    2012-01-01

    Selective catalytic reduction (SCR) of NOx is a widely applied diesel engine exhaust gas aftertreatment technology. For advanced SCR process control, like model predictive control, full state information of the process is required. The ammonia coverage ratio inside the catalyst is difficult to me...

  12. Inhibitory Effect of Crizotinib on Creatinine Uptake by Renal Secretory Transporter OCT2.

    Science.gov (United States)

    Arakawa, Hiroshi; Omote, Saki; Tamai, Ikumi

    2017-09-01

    Crizotinib, a tyrosine kinase inhibitor, exhibits some cases of an increase in serum creatinine levels. Creatinine is excreted by not only glomerular filtration but also active secretion by organic cation transporters such as organic cation transporter 2 (OCT2). In the present study, we evaluated in vitro inhibitory effect of crizotinib on OCT2 by directly measuring creatinine uptake by OCT2. Coincubation of crizotinib reduced uptake of [ 14 C]creatinine by cultured HEK293 cells expressing OCT2 (HEK293/OCT2) in a concentration-dependent manner with IC 50 values of 1.58 ± 0.24 μM. Preincubation or both preincubation and coincubation (preincubation/coincubation) with crizotinib showed stronger inhibitory effect on [ 14 C]creatinine uptake compared with that in coincubation alone with IC 50 values of 0.499 ± 0.076 and 0.347 ± 0.040 μM, respectively. These IC 50 values of crizotinib on [ 3 H]N-methyl-4-phenylpyridinium acetate uptake by OCT2 were 10-20 times higher than those of [ 14 C]creatinine uptake. Furthermore, preincubation of crizotinib inhibited creatinine uptake by OCT2 in an apparently competitive manner. In conclusion, crizotinib at a clinically relevant concentration has the potential to inhibit creatinine transport by OCT2, suggesting an increase of serum creatinine levels in clinical use. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  13. HiSCR (Hidradenitis Suppurativa Clinical Response)

    DEFF Research Database (Denmark)

    Kimball, B. A.; Sobell, J. M.; Zouboulis, C C

    2016-01-01

    Background: Determining treatment response for patients with hidradenitis suppurativa (HS) can be challenging due to limitations of current disease activity evaluations. Objective: Evaluate the novel, validated endpoint, Hidradenitis Suppurativa Clinical Response (HiSCR) and its utility as an out......Background: Determining treatment response for patients with hidradenitis suppurativa (HS) can be challenging due to limitations of current disease activity evaluations. Objective: Evaluate the novel, validated endpoint, Hidradenitis Suppurativa Clinical Response (HiSCR) and its utility...... as an outcome measure. Methods: Patients with baseline total abscess and inflammatory nodule count (AN count) of at least three and draining fistula count of 20 or fewer comprised the post hoc subpopulation analysed. HiSCR (at least a 50% reduction in total AN count, with no increase in abscess count...... week, or placebo (1 : 1 : 1). Results: The subpopulation included 132 (85.7%) patients; 70.5% women and 73.5% white. At week 16, HiSCR was achieved by 54.5% receiving weekly adalimumab, 33.3% every other week, and 25.6% placebo and HS-PGA Response was achieved by 20.5% receiving weekly adalimumab, 6...

  14. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  15. Age- and sex-specific reference limits for creatinine, cystatin C and the estimated glomerular filtration rate.

    Science.gov (United States)

    Hannemann, Anke; Friedrich, Nele; Dittmann, Kathleen; Spielhagen, Christin; Wallaschofski, Henri; Völzke, Henry; Rettig, Rainer; Endlich, Karlhans; Lendeckel, Uwe; Stracke, Sylvia; Nauck, Matthias

    2011-11-14

    Early detection of patients with chronic kidney disease is of great importance. This study developed reference limits for serum creatinine and serum cystatin C concentrations and for the estimated glomerular filtration rate (eGFR) in healthy subjects from the general population aged 25-65 years. This study defined a reference population including 985 subjects from the first follow-up of the Study of Health in Pomerania. Serum creatinine was measured with a modified kinetic Jaffé method. Serum cystatin C was measured with a nephelometric assay. The eGFR was calculated from serum creatinine according to the Cockcroft-Gault (eGFR(CG)) and the Modification of Diet in Renal Disease (eGFR(MDRD)) equation, respectively, as well as from serum cystatin C according to the formula by Larsson (eGFR(Larsson)). Non-parametric quantile regression was used to estimate the reference limits. For serum creatinine and serum cystatin C the 95th percentile and for eGFR(CG), eGFR(MDRD) and eGFR(Larsson) the 5th percentile were selected as reference limits. All data was weighted to reflect the age- and sex-structure of the German population in 2008. The reference limits for serum creatinine (men: 1.11-1.23 mg/dL; women: 0.93-1.00 mg/dL) and serum cystatin C levels (men: 0.92-1.04 mg/L; women: 0.84-1.02 mg/L) increased with advancing age. The reference limits for eGFR decreased with increasing age (eGFR(CG) men: 106.0-64.7 mL/min, women 84.4-57.9 mL/min; eGFR(MDRD) men: 82.5-62.2 mL/min/1.73 m², women 75.0-58.2 mL/min/1.73 m²; eGFR(Larsson) men: 85.5-72.9 mL/min, women 94.5-75.7 mL/min). This study presents age- and sex-specific reference limits for five measures of renal function based on quantile regression models.

  16. A joint model for longitudinal and time-to-event data to better assess the specific role of donor and recipient factors on long-term kidney transplantation outcomes

    DEFF Research Database (Denmark)

    Fournier, Marie-Cécile; Foucher, Yohann; Blanche, Paul

    2016-01-01

    and 2013 with a functioning kidney at 1-year post-transplantation were obtained from the DIVAT cohort. A shared random effect joint model for longitudinal SCr values and time to graft failure was performed. We show that graft failure risk depended on both the current value and slope of the SCr. Deceased......In renal transplantation, serum creatinine (SCr) is the main biomarker routinely measured to assess patient's health, with chronic increases being strongly associated with long-term graft failure risk (death with a functioning graft or return to dialysis). Joint modeling may be useful to identify...... the specific role of risk factors on chronic evolution of kidney transplant recipients: some can be related to the SCr evolution, finally leading to graft failure, whereas others can be associated with graft failure without any modification of SCr. Sample data for 2749 patients transplanted between 2000...

  17. Evaluation the short term effects on serum creatinine concentration in patients with normal renal function, mild and moderate renal insufficiency after intravenous injection of gadopentetate dimeglumine

    International Nuclear Information System (INIS)

    Luo Jian; Liu Jing; Wang Xiaoying; Yang Xuedong; Jiang Xuexiang

    2010-01-01

    Objective: To explore the effects of gadopentetate dimeglumine injection on renal function. Methods: The study included 623 consecutive patients. Their serum creatinine concentrations before and within 3 days after injection of gadopentetate dimeglumine were analyzed. Their eGFR (estimated glomerular filtration rate) were calculated. Patients were divided into two groups according to their injection dose: group received single dose and group received double dose. Patients in each group were subdivided into three subgroups according to their eGFR: subgroup of normal renal function, subgroup of mild renal insufficiency and subgroup of moderate renal insufficiency. Paried sample t test and group design paired sample Rank Sum test were used for statistical analysis. Results: There was no adverse reaction or occurrence of acute renal insufficiency. The mean level of serum creatinine dropped from (74.0± 17.2) μmol/L to (71.5±19.0) μmol/L (t=5.39, P 0.05) in subgroup of mild renal insufficiency under group received double dose and increased from (118.3±15.3) μmol/L to (135.7±8.5) μmol/L (t=2.02, P<0.05) in subgroup of moderate renal insufficiency under group received double dose, the mean level of serum creatinine dropped in all other subgroups. Conclusions: Single dose gadopentetate dimeglumine is safe for patients with normal renal function and mild, moderate renal insufficiency in short term, but patients with abnormal renal function should be followed up after double dose injection. (authors)

  18. Proximal Tubular Secretion of Creatinine by Organic Cation Transporter OCT2 in Cancer Patients

    Science.gov (United States)

    Ciarimboli, Giuliano; Lancaster, Cynthia S.; Schlatter, Eberhard; Franke, Ryan M.; Sprowl, Jason A.; Pavenstädt, Hermann; Massmann, Vivian; Guckel, Denise; Mathijssen, Ron H. J.; Yang, Wenjian; Pui, Ching-Hon; Relling, Mary V.; Herrmann, Edwin; Sparreboom, Alex

    2012-01-01

    Purpose Knowledge of transporters responsible for the renal secretion of creatinine is key to a proper interpretation of serum creatinine and/or creatinine clearance as markers of renal function in cancer patients receiving chemotherapeutic agents. Experimental Design Creatinine transport was studied in transfected HEK293 cells in vitro and in wildtype mice and age-matched organic cation transporter 1 and 2-deficient [Oct1/2(−/−)] mice ex vivo and in vivo. Clinical pharmacogenetic and transport inhibition studies were done in two separate cohorts of cancer patients. Results Compared to wildtype mice, creatinine clearance was significantly impaired in Oct1/2(−/−) mice. Furthermore, creatinine inhibited organic cation transport in freshly-isolated proximal tubules from wild-type mice and humans, but not in those from Oct1/2(−/−) mice. In a genetic-association analysis (n=590), several polymorphisms around the OCT2/SLC22A2 gene locus, including rs2504954 (P=0.000873), were significantly associated with age-adjusted creatinine levels. Furthermore, in cancer patients (n=68), the OCT2 substrate cisplatin caused an acute elevation of serum creatinine (P=0.0083), consistent with inhibition of an elimination pathway. Conclusions Collectively, this study shows that OCT2 plays a decisive role in the renal secretion of creatinine. This process can be inhibited by OCT2 substrates, which impair the usefulness of creatinine as a marker of renal function. PMID:22223530

  19. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  20. Plasma NGAL predicts early acute kidney injury no earlier than s-creatinine or cystatin C in severely burned patients.

    Science.gov (United States)

    Rakkolainen, Ilmari; Vuola, Jyrki

    2016-03-01

    Neutrophil gelatinase-associated lipocalin (NGAL) is a novel biomarker used in acute kidney injury (AKI) diagnostics. Studies on burn patients have highlighted it as a promising biomarker for early detection of AKI. This study was designed to discover whether plasma NGAL is as a biomarker superior to serum creatinine and cystatin C in detecting AKI in severely burned patients. Nineteen subjects were enrolled from March 2013 to September 2014 in the Helsinki Burn Centre. Serum creatinine, cystatin C, and plasma NGAL were collected from the patients at admission and every 12h during the first 48h and thereafter daily until seven days following admission. AKI was defined by acute kidney injury network criteria. Nine (47%) developed AKI during their intensive care unit stay and two (11%) underwent renal replacement therapy. All biomarkers were significantly higher in the AKI group but serum creatinine- and cystatin C values reacted more rapidly to changes in kidney function than did plasma NGAL. Plasma NGAL tended to rise on average 72h±29h (95% CI) later in patients with early AKI than did serum creatinine. Area-under-the-curve values calculated for each biomarker were 0.92 for serum creatinine, 0.87 for cystatin C, and 0.62 for plasma NGAL predicting AKI by the receiver-operating-characteristic method. This study demonstrated serum creatinine and cystatin C as faster and more reliable biomarkers than plasma NGAL in detecting early AKI within one week of injury in patients with severe burns. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  1. Detecting reduced renal function in children

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Erlandsen, Erland J

    2013-01-01

    Background The aim of this study was to compare the ability of renal indicators [serum creatinine (SCr), cystatin C (SCysC)] and glomerular filtration rate (GFR)-models to discriminate normal and reduced renal function. As a single cut-off level will always lead to false classifications, we propose...... function was defined as a GFR ofcreatinine (SCr-ratio), and eight published GFR-models were compared for their ability to correctly classify renal function as normal or reduced. Cut-off levels were determined so as to give 99 % certainty outside the gray zone...

  2. [A patient with high creatinine levels but no renal failure: reversed autodialysis in a patient with a ruptured bladder].

    Science.gov (United States)

    Raeymaeckers, Steven; Tosi, Maurizio; Van Bael, Kobe; Brussaard, Carola; De Mey, Johan

    2016-01-01

    In case of a ruptured bladder with urine leakage into the peritoneal cavity 'reversed autodialysis' can occur, in which urea and creatinine diffuse back into the bloodstream via the peritoneum. This causes clinical signs of pseudorenal failure, with raised concentrations of creatinine and urea. The urea/creatinine ratio does not change. A 34-year-old female patient experienced increasing abdominal pain 3 days after laparoscopic myomectomy. Acute renal failure was suspected because of increased serum concentrations of creatinine and urea, but no cause could be found. There was a build-up of fluid in the abdominal cavity, which proved to be urine originating from an iatrogenic rupture of the bladder. Serum levels normalised following repair of the rupture. If serum creatinine levels rise rapidly following abdominal surgery or blunt abdominal trauma the bladder should be examined for possible perforation, particularly if the abdominal dimension increases. A ruptured bladder leading to pseudorenal failure is an indication for rapid surgical intervention.

  3. Hybrid selective noncatalytic reduction (SNCR)/selective catalytic reduction (SCR) for NOx removal using low-temperature SCR with Mn-V2O5/TiO2 catalyst.

    Science.gov (United States)

    Choi, Sung-Woo; Choi, Sang-Ki; Bae, Hun-Kyun

    2015-04-01

    A hybrid selective noncatalytic reduction/selective catalytic reduction (SNCR/SCR) system that uses two types of technology, low-temperature SCR process and SNCR process, was designed to develop nitrogen oxide (NOx) reduction technology. SCR was conducted with space velocity (SV)=2400 hr(-1) and hybrid SNCR/SCR with SV=6000 hr(-1), since the study focused on reducing the amount of catalyst and both achieved 98% NOx reduction efficiency. Characteristics of NOx reduction by NH3 were studied for low-temperature SCR system at 150 °C using Mn-V2O5/TiO2 catalyst. Mn-added V2O5/TiO2 catalyst was produced, and selective catalyst reduction of NOx by NH3 was experimented. NOx reduction rate according to added Mn content in Mn-V2O5/TiO2 catalyst was studied with varying conditions of reaction temperature, normalized stoichiometric ratio (NSR), SV, and O2 concentration. In the catalyst experiment according to V2O5 concentration, 1 wt.% V2O5 catalyst showed the highest NOx reduction rate: 98% reduction at temperature window of 200~250 °C. As a promoter of the V2O5 catalyst, 5 wt.% Mn was added, and the catalyst showed 47~90% higher efficiency even with low temperatures, 100~200 °C. Mn-V2O5/TiO2 catalyst, prepared by adding 5 wt.% Mn in V2O5/TiO2 catalyst, showed increments of catalyst activation at 150 °C as well as NOx reduction. Mn-V2O5/TiO2 catalyst showed 8% higher rate for NOx reduction compared with V2O5/TiO2 catalyst in 150 °C SCR. Thus, (5 wt.%)Mn-(1 wt.%)V2O5/TiO2 catalyst was applied in SCR of hybrid SNCR/SCR system of low temperature at 150 °C. Low-temperature SCR hybrid SNCR/SCR (150 °C) system and hybrid SNCR/SCR (350 °C) showed 91~95% total reduction rate with conditions of SV=2400~6000 hr(-1) SCR and 850~1050 °C SNCR, NSR=1.5~2.0, and 5% O2. Hybrid SNCR/SCR (150 °C) system proved to be more effective than the hybrid SNCR/SCR (350 °C) system at low temperature. NOx control is very important, since they are the part of greenhouse gases as well as the

  4. Comparison of cystatin C- and creatinine-based estimated glomerular filtration rate to predict coronary heart disease risk in Japanese patients with obesity and diabetes.

    Science.gov (United States)

    Ito, Ryo; Yamakage, Hajime; Kotani, Kazuhiko; Wada, Hiromichi; Otani, Sumire; Yonezawa, Kazuya; Ogo, Atsushi; Okajima, Taiichiro; Adachi, Masahiro; Araki, Rika; Yoshida, Kazuro; Saito, Miho; Nagaoka, Tadasu; Toyonaga, Tetsushi; Tanaka, Tsuyoshi; Yamada, Tsutomu; Ota, Itsuro; Oishi, Mariko; Miyanaga, Fumiko; Shimatsu, Akira; Satoh-Asahara, Noriko

    2015-01-01

    The aim of this study is to determine which indicator of chronic kidney disease most closely correlates with 10-year Framingham coronary heart disease (CHD) risk among serum creatinine, serum cystatin C (S-CysC), urine albumin-creatinine ratio (UACR), estimated creatinine-based GFRs (eGFRcre), and estimated CysC-based GFRs (eGFRcys) in patients with obesity and diabetes. Serum creatinine, S-CysC, UACR, and cardio-ankle vascular index (CAVI) were examined in 468 outpatients with obesity and type 2 diabetes, free of severe renal dysfunction or previous history of cardiovascular disease, as a cross-sectional survey using baseline data from the multi-centered Japan Diabetes and Obesity Study. S-CysC and eGFRcys had significantly stronger correlations with the 10-year Framingham CHD risk than serum creatinine, eGFRcre, and UACR (creatinine, ρ = 0.318; S-CysC, ρ = 0.497; UACR, ρ = 0.174; eGFRcre, ρ = -0.291; eGFRcys, ρ = -0.521; P obesity and diabetes.

  5. Impact of Gate 99mTc DTPA GFR, Serum Creatinine and Urea in Diagnosis of Patients with Chronic Kidney Failure

    Science.gov (United States)

    Miftari, Rame; Nura, Adem; Topçiu-Shufta, Valdete; Miftari, Valon; Murseli, Arbenita; Haxhibeqiri, Valdete

    2017-01-01

    Aim: The aim of this study was determination of validity of 99mTcDTPA estimation of GFR for early detection of chronic kidney failure Material and methods: There were 110 patients (54 males and 56 females) with kidney disease referred for evaluation of renal function at UCC of Kosovo. All patients were included in two groups. In the first group were included 30 patients confirmed with renal failure, whereas in the second group were included 80 patients with other renal disease. In study were included only patients with ready results of creatinine, urea and glucose in the blood serum. For estimation of GFR we have used the Gate GFR DTPA method. The statistical data processing was conducted using statistical methods such as arithmetic average, the student t-test, percentage or rate, sensitivity, specificity and accuracy of the test. Results: The average age of all patients was 36 years old. The average age of female was 37 whereas of male 35. Patients with renal failure was significantly older than patients with other renal disease (p<0.005). Renal failure was found in 30 patients (27.27%). The concentration of urea and creatinine in blood serum of patients with renal failure were significantly higher than in patients with other renal disease (P< 0.00001). GFR in patients with renal failure were significantly lower than in patients with other renal disease, 51.75 ml/min (p<0.00001). Sensitivity of uremia and creatininemia for detection of renal failure were 83.33%, whereas sensitivity of 99mTcDTPA GFR was 100%. Specificity of uraemia and creatininemia were 63% whereas specificity of 99mTcDTPA GFR was 47.5%. Diagnostic accuracy of blood urea and creatinine in detecting of renal failure were 69%, whereas diagnostic accuracy of 99mTcDTPA GFR was 61.8%. Conclusion: Gate 99mTc DTPA scintigraphy in collaboration with biochemical tests are very sensitive methods for early detection of patients with chronic renal failure. PMID:28883673

  6. Evaluation of serum angiopoietin-II in HCV related ...

    African Journals Online (AJOL)

    Hoda A. Abd-El-Moety

    2011-08-30

    Aug 30, 2011 ... blood urea, serum creatinine, serum uric acid, ALT, AST, total and direct bilirubin ... factor, cryoglobulins31–33 and urinary albumin creatinine ratio ..... reported that VEGF stimulates increased synthesis of collage- nase by ...

  7. Selective catalytic reduction (SCR) NOx control for small natural gas-fired prime movers

    International Nuclear Information System (INIS)

    Shareef, G.S.; Stone, D.K.; Ferry, K.R.; Johnson, K.L.; Locke, K.S.

    1992-01-01

    The application of selective catalytic reduction (SCR) to small natural gas-fired prime movers at cogeneration facilities and compressor stations could possibly increase due to regulatory forces to limit NO x from such sources. The natural gas industry is presently without a current database with which to evaluate the cost and operating characteristics of SCR under the conditions anticipated for small prime movers. This paper presents the results from a two-phase study undertaken to document SCR applications with emphasis on SCR system performance and costs. The database of small natural gas-fired prime mover SCR experience, focusing on prime mover characterization, SCR system performance, and SCR system costs will be described. Result from analysis of performance and cost data will be discussed, including analytical tools developed to project SCR system performance and costs

  8. Selective Catalytic Reduction (SCR) for mobile application - heavy duty diesel; Selektive Katalytische Reduktion (SCR) fuer die mobile Anwendung - LKW

    Energy Technology Data Exchange (ETDEWEB)

    Huennekes, E.; Neubauer, T. [Engelhard Technologies GmbH, Hannover (Germany); Roth, S.A.; Patchett, J.A. [Engelhard Corp., R and D, Iselin, NJ (United States)

    2006-07-01

    Different system configurations of particulate and NOx control via selective catalytic reduction (SCR) were discussed. Advantages and disadvantages were described and the final choice of the optimum system will strongly depend on the application, the market (US, EU) and the system costs. Especially when considering low temperature NOx control, the optimum adjustment of the NO{sub 2}/NO{sub x} ratio in front of an SCR system plays an important role. When generating NO2 over an oxidation catalyst, the resulting NO{sub 2}/NO{sub x} ratio strongly depends on temperature and space velocity. Steady state data show an optimum NO{sub 2}/NO{sub x} ratio between 35 and 60% at temperatures about 240 C. Three DOC systems in front of an SCR system were investigated with the purpose to generate high, low and optimum NO{sub 2}/NO{sub x} ratios. The fast SCR reaction at 1:1 NO: NO2 with NH{sub 3} is the preferred reaction pathway until either NO or NO{sub 2} are consumed. The benefit of an optimum designed DOC system can be seen in the transient response after a sudden increase in urea dosing. The time for the optimum designed system to reach maximum NO{sub x} conversion is much shorter compared with systems having excess NO or NO{sub 2} Ammonia oxidation catalysts (AMOX) are effective means in controlling ammonia from SCR systems. To be effective, AMOX must have selectivity to nitrogen over N{sub 2}O and NO{sub x}. (orig.)

  9. The J3 SCR model applied to resonant converter simulation

    Science.gov (United States)

    Avant, R. L.; Lee, F. C. Y.

    1985-01-01

    The J3 SCR model is a continuous topology computer model for the SCR. Its circuit analog and parameter estimation procedure are uniformly applicable to popular computer-aided design and analysis programs such as SPICE2 and SCEPTRE. The circuit analog is based on the intrinsic three pn junction structure of the SCR. The parameter estimation procedure requires only manufacturer's specification sheet quantities as a data base.

  10. Hydrolysis of isocyanic acid on SCR catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Elsener, M; Kleemann, M; Koebel, M [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Standard SCR catalysts possess high activity for the hydrolysis of HNCO and thus explain the suitability of urea as a selective reducing agent for NO{sub x}. At high space velocities HNCO-slip can get perceptible over the entire temperature range. This can be attributed to the fact that the temperature dependence is strong for the SCR reaction, but weak for the hydrolysis reaction. (author) 3 figs., 5 refs.

  11. Urea-SCR Temperature Investigation for NOx Control of Diesel Engine

    Directory of Open Access Journals (Sweden)

    Asif Muhammad

    2015-01-01

    Full Text Available SCR (selective catalytic reduction system is continuously being analyzed by many researchers worldwide on various concerns due to the stringent nitrogen oxides (NOx emissions legislation for heavy-duty diesel engines. Urea-SCR includes AdBlue as urea source, which subsequently decomposes to NH3 (ammonia being the reducing agent. Reaction temperature is a key factor for the performance of urea-SCR system, as urea decomposition rate is sensitive to a specific temperature range. This particular study was directed to investigate the temperature of the SCR system in diesel engine with the objective to confirm that whether the appropriate temperature is attained for occurrence of urea based catalytic reduction or otherwise and how the system performs on the prescribed temperature range. Diesel engine fitted with urea-SCR exhaust system has been operated on European standard cycle for emission testing to monitor the temperature and corresponding nitrogen oxides (NOx values on specified points. Moreover, mathematical expressions for approximation of reaction temperature are also proposed which are derived by applying energy conservation principal and gas laws. Results of the investigation have shown that during the whole testing cycle system temperature has remained in the range where urea-SCR can take place with best optimum rate and the system performance on account of NOx reduction was exemplary as excellent NOx conversion rate is achieved. It has also been confirmed that selective catalytic reduction (SCR is the best suitable technology for automotive engine-out NOx control.

  12. The protective effect of SCR(15-18) on cerebral ischemia-reperfusion injury.

    Science.gov (United States)

    Li, Shu; Xian, Jinhong; He, Li; Luo, Xue; Tan, Bing; Yang, Yongtao; Liu, Gaoke; Wang, Zhengqing

    2011-10-01

    Soluble complement receptor type 1 (sCR1), a potent inhibitor of complement activation, has been shown to protect brain cells against cerebral ischemic/reperfusion (CI/R) injury due to its decay-accelerating activity for C3/C5 convertase and co-factor activity for C3b/C4b degradation. However, the effect of short consensus repeats (SCRs) 15-18, one of active domains of sCR1 with high C3b/C4b degradability, has not been demonstrated. Here, we investigated the protective effect of recombinant SCR(15-18) protein in middle cerebral artery occlusion (MCAO)-induced focal CI/R injury. Recombinant SCR(15-18) protein was successfully expressed in Escherichia coli and refolded to its optimal bioactivity. Seventy-five Sprague-Dawley rats were randomly assigned into three groups: sham-operated group, CI/R group, and SCR(15-18)+CI/R group pretreated with 20 mg/kg SCR(15-18) protein. After 2 hours of MCAO and subsequent 24 hours of reperfusion, rats were evaluated for neurological deficits and cerebral infarction. Polymorphonuclear leukocyte accumulation, C3b deposition, and morphological changes in cerebral tissue were also estimated. SCR(15-18) pretreatment induced a 20% reduction of infarct size and an improvement of neurological function with 22·2% decrease of neurological deficit scores. Inhibition of cerebral neutrophils infiltration by SCR(15-18) was indicated from the reduction of myeloperoxidase activity in SCR(15-18)+CI/R rats. Decreased C3b deposition and improved morphological changes were also found in cerebral tissue of SCR(15-18)-treated rats. Our studies suggest a definitive moderately protective effect of SCR(15-18) against CI/R damage and provide preclinical experimental evidence supporting the possibility of using it as a small anti-complement therapeutic agent for CI/R injury therapy.

  13. Clinical Usefulness of Serum Cystatin C as a Marker of Renal Function

    Directory of Open Access Journals (Sweden)

    Kwang-Sook Woo

    2014-08-01

    Full Text Available BackgroundAccurate renal function measurements are important in the diagnosis and treatment of kidney diseases. In contrast to creatinine, the production of serum cystatin C has been extensively reported to be unaffected by body muscle mass, age, gender, and nutritional status.MethodsOur study included 37 samples from diabetic chronic kidney disease (CKD patients for whom serum creatinine tests had been requested and 40 samples from a healthy populations in Dong-A University Hospital between May 2010 and June 2010. The assay precision (i.e., the coefficient of variation and the reference range of the serum cystatin C test were evaluated. We compared the estimated glomerular filtration rates (GFRs based on cystatin C with those based on creatinine. Moreover, we investigated the influences of age, gender, weight, and muscle mass on serum creatinine and serum cystatin C.ResultsThere was a positive correlation between GFR based on creatinine and that based on cystatin C (r=0.79, P<0.0001 among the diabetic CKD patients. Serum creatinine and cystatin C were significantly correlated with body weight and muscle mass, but the strengths of these correlations were greater for serum creatinine. The precision study revealed excellent results for both the high and low controls. The 95% reference interval of cystatin C in the healthy population was 0.371 to 1.236 mg/L.ConclusionBased on these results, we conclude that, despite the strong correlation between serum creatinine and cystatin C, cystatin C is less affected by weight and muscle mass and might represent a better alternative for the assessment of renal function.

  14. Impacts of acid gases on mercury oxidation across SCR catalyst

    International Nuclear Information System (INIS)

    Zhuang, Ye; Laumb, Jason; Liggett, Richard; Holmes, Mike; Pavlish, John

    2007-01-01

    A series of bench-scale experiments were completed to evaluate acid gases of HCl, SO 2 , and SO 3 on mercury oxidation across a commercial selective catalytic reduction (SCR) catalyst. The SCR catalyst was placed in a simulated flue gas stream containing O 2 , CO 2 , H 2 O, NO, NO 2 , and NH 3 , and N 2 . HCl, SO 2 , and SO 3 were added to the gas stream either separately or in combination to investigate their interactions with mercury over the SCR catalyst. The compositions of the simulated flue gas represent a medium-sulfur and low- to medium-chlorine coal that could represent either bituminous or subbituminous. The experimental data indicated that 5-50 ppm HCl in flue gas enhanced mercury oxidation within the SCR catalyst, possibly because of the reactive chlorine species formed through catalytic reactions. An addition of 5 ppm HCl in the simulated flue gas resulted in mercury oxidation of 45% across the SCR compared to only 4% mercury oxidation when 1 ppm HCl is in the flue gas. As HCl concentration increased to 50 ppm, 63% of Hg oxidation was reached. SO 2 and SO 3 showed a mitigating effect on mercury chlorination to some degree, depending on the concentrations of SO 2 and SO 3 , by competing against HCl for SCR adsorption sites. High levels of acid gases of HCl (50 ppm), SO 2 (2000 ppm), and SO 3 (50 ppm) in the flue gas deteriorate mercury adsorption on the SCR catalyst. (author)

  15. Serum Creatinine in Patients with Advanced Liver Disease Is of Limited Value for Identification of Moderate Renal Dysfunction: Are the Equations for Estimating Renal Function Better?

    Directory of Open Access Journals (Sweden)

    Jillian MacAulay

    2006-01-01

    Full Text Available BACKGROUND: The Cockcroft-Gault formula (CGF is used to estimate the glomerular filtration rate (GFR based on serum creatinine (Cr levels, age and sex. A new formula developed by the Modification of Diet in Renal Disease (MDRD Study Group, based on the patient’s Cr levels, age, sex, race and serum urea nitrogen and serum albumin levels, has shown to be more accurate. However, the best formula to identify patients with advanced liver disease (ALD and moderate renal dysfunction (GFR 60 mL/min/1.73 m2 or less is not known. The aim of the present study was to compare calculations of GFR, using published formulas (excluding those requiring urine collections with standard radionuclide measurement of GFR in patients with ALD.

  16. Ethamsylate (Dicynone) interference in determination of serum creatinine, uric acid, triglycerides, and cholesterol in assays involving the Trinder reaction; in vivo and in vitro.

    Science.gov (United States)

    Dastych, Milan; Wiewiorka, Ondrej; Benovská, Miroslava

    2014-01-01

    The aim of our research was the quantification of interfering properties of the haemostatic drug Dicynone (ethamsylate) in serum creatinine, uric acid, cholesterol, and triglyceride assays using the Trinder reaction. Blood from patients was collected before and 15 minutes after administration of 500 mg Dicynone dose i.v. and the above mentioned analytes were quantified using Roche assays (Cobas 8000). In our in vitro experiment, we measured concentrations of the analytes in pooled serum aliquots with final concentrations of Dicynone additions 0, 30, 60, 150, and 300 mg/L. Aliquots with 60 mg/L Dicynone were also measured at 2, 6, and 8 hours after initial measurement when stored in 22 degrees C and 4 degrees C for comparison. Concentrations of the measured analytes in samples from patients administered with a 500 mg dose of Dicynone were lower in all cases (n = 10) when compared to values in samples taken immediately before treatment. The in vitro samples showed that considerable negative interference occurred even with the low concentrations of Dicynone additions (30 and 60 mg/L), showing the strongest negative interference in creatinine values, followed by uric acid, triglycerides, and cholesterol. Using in vitro samples, we showed strong time and temperature dependence on Dicynone interference. We found and proved significant negative interference of the drug Dicynone (ethamsylate) in the clinical analysis of blood using in vivo and in vitro experiments. Furthermore, we observed a change of this effect in serum matrix over time and at different storage temperatures.

  17. Serum creatinine elevation after renin-angiotensin system blockade and long term cardiorenal risks: cohort study.

    Science.gov (United States)

    Schmidt, Morten; Mansfield, Kathryn E; Bhaskaran, Krishnan; Nitsch, Dorothea; Sørensen, Henrik Toft; Smeeth, Liam; Tomlinson, Laurie A

    2017-03-09

    Objective  To examine long term cardiorenal outcomes associated with increased concentrations of creatinine after the start of angiotensin converting enzyme inhibitor/angiotensin receptor blocker treatment. Design  Population based cohort study using electronic health records from the Clinical Practice Research Datalink and Hospital Episode Statistics. Setting  UK primary care, 1997-2014. Participants  Patients starting treatment with angiotensin converting enzyme inhibitors or angiotensin receptor blockers (n=122 363). Main outcome measures  Poisson regression was used to compare rates of end stage renal disease, myocardial infarction, heart failure, and death among patients with creatinine increases of 30% or more after starting treatment against those without such increases, and for each 10% increase in creatinine. Analyses were adjusted for age, sex, calendar period, socioeconomic status, lifestyle factors, chronic kidney disease, diabetes, cardiovascular comorbidities, and use of other antihypertensive drugs and non-steroidal anti-inflammatory drugs. Results  Among the 2078 (1.7%) patients with creatinine increases of 30% or more, a higher proportion were female, were elderly, had cardiorenal comorbidity, and used non-steroidal anti-inflammatory drugs, loop diuretics, or potassium sparing diuretics. Creatinine increases of 30% or more were associated with an increased adjusted incidence rate ratio for all outcomes, compared with increases of less than 30%: 3.43 (95% confidence interval 2.40 to 4.91) for end stage renal disease, 1.46 (1.16 to 1.84) for myocardial infarction, 1.37 (1.14 to 1.65) for heart failure, and 1.84 (1.65 to 2.05) for death. The detailed categorisation of increases in creatinine concentrations (creatinine increases of less than 30% were also associated with increased incidence rate ratios for all outcomes, including death (1.15 (1.09 to 1.22) for increases of 10-19% and 1.35 (1.23 to 1.49) for increases of 20-29%, using creatinine

  18. SERUM PARAOXONASE ACTIVITY IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    Saritha Gadicherla

    2017-12-01

    Full Text Available BACKGROUND Serum paraoxonase is an enzyme synthesised in the liver. It is known to prevent atherosclerosis by inhibiting oxidation of lowdensity lipoprotein. Renal transplant recipients have increased tendency for developing atherosclerosis and cardiovascular disease. Reduced activity of serum paraoxonase contributes to accelerated atherosclerosis and increased cardiovascular complications in these patients. The aim of this study was to estimate serum paraoxonase activity in renal transplant recipients and compare it with healthy controls. MATERIALS AND METHODS 30 renal transplant recipients and 30 age and sex matched healthy controls were taken for the study. Serum paraoxonase activity, blood urea, serum creatinine and uric acid were estimated in these groups. The serum paraoxonase activity was correlated with urea, creatinine and uric acid levels. RESULTS Serum paraoxonase activity was reduced in renal transplant recipients compared to healthy controls. There was a negative correlation between paraoxonase activity and the levels of urea, creatinine and uric acid levels. CONCLUSION In this study, the paraoxonase activity was reduced in renal transplant recipients compared to controls. The increased cardiovascular disease in these patients could be due to reduced paraoxonase activity.

  19. Retrofit SCR system for NOx control from heavy-duty mining equipment

    International Nuclear Information System (INIS)

    Mannan, M.A.

    2009-01-01

    Diesel engines are used extensively in the mining industry and offer many advantages. However, particulate matter (PM) emissions and nitrogen oxide emissions (NOx) are among its disadvantages. A significant concern related to PM and NOx in an underground mine involves the use of diesel exhaust after treatment systems such as diesel particulate filters and selective catalytic reduction (SCR). This presentation discussed NOx and PM control and provided a description of an SCR system and examples of SCR retrofits. Options for NOx control were discussed and a case study involving the installation of an SCR retrofit system in an underground mine operated by Sifto Salt was also presented. The purpose of the case study was to identify cost effective retrofit solutions to lower nitrogen dioxide emissions from heavy-duty trucks operating in underground mines. The case study illustrated and presented the candidate vehicle, baseline emissions, a BlueMax SCR retrofit solution, and BlueMax installation. 1 tab., 6 figs.

  20. System analysis regarding NO{sub x} reduction with combined SNCR/SCR; Systemstudie avseende kombinerad NO{sub x}-reducering med SNCR/SCR

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Therese; Henningsson, Claes [S.E.P. Scandinavian Energy Project AB, Stockholm (Sweden); Andersson, Christer [Vattenfall Utveckling AB, Stockholm (Sweden)

    2000-06-01

    Systems with combined SNCR/SCR on biomass fired CFB:s have been focused on lately since they are regarded as very load flexible. Furthermore, synergy effects between the two parts are supposed to result in better performance for the combined system than for the two systems separately. The aim of this study is to investigate whether the combined SNCR/SCR matches the outlined expectations above. The plant chosen for the measurements was Brista Kraft AB. This particular plant is equipped with a CFB boiler of 122 MW{sub th}, which in turn is equipped with the deNO{sub x} system mentioned above. The measurements are made by a 'concentration gradient measurement system', developed by Vattenfall. Consequently, the study indicates that it is very useful to add a catalyst to the SNCR system, both from an environmental- and an economical point of view. However, since the full scale data for the SCR alone is missing, the results for SCR compared with combined SNCR/SCR is harder to decide. Simulations indicate that both systems produces the same emission levels, although, the SCR system may be a bit more cost effective in the long run. The synergy effect between the systems in combination is obvious. Predominantly because the NO{sub x} reduction efficiency in the SNCR zone can be increased (in this case about 10-12%) since a higher amount of ammonia can be accepted downstream of the SNCR zone. Combined systems will achieve a comparable good load independence. The reduction in the SNCR will decrease at lower loads, simultaneously as the reduction in the SCR increases. Thus, the total reduction efficiency will almost be independent of the load. In the project investigations have been made to figure out if two points injection in SNCR give more or less mol distribution of NH{sub 3}/NO quota over the catalyst crosses sectional area. The measurements indicates that two point injection may cause a more uneven distribution of stoichiometries. However, the results seems to

  1. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.

    Science.gov (United States)

    Nah, Hyunjin; Lee, Sang-Guk; Lee, Kyeong-Seob; Won, Jae-Hee; Kim, Hyun Ok; Kim, Jeong-Ho

    2016-02-01

    The aim of this study was to estimate bilirubin interference and accuracy of six routine methods for measuring creatinine compared with isotope dilution-liquid chromatography mass spectrometry (ID-LC/MS). A total of 40 clinical serum samples from 31 patients with serum total bilirubin concentration >68.4μmol/L were collected. Serum creatinine was measured using two enzymatic reagents and four Jaffe reagents as well as ID-LC/MS. Correlations between bilirubin concentration and percent difference in creatinine compared with ID-LC/MS were analyzed to investigate bilirubin interference. Bias estimations between the six reagents and ID-LC/MS were performed. Recovery tests using National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 967a were also performed. Both the enzymatic methods showed no bilirubin interference. However, three of the four Jaffe methods demonstrated significant bilirubin concentration-dependent interference in samples with creatinine levels creatinine levels ranging from 53.0 to 97.2μmol/L. Comparison of these methods with ID-LC/MS using patients' samples with elevated bilirubin revealed that the tested methods failed to achieve the bias goal at especially low levels of creatinine. In addition, recovery test using NIST SRM 967a showed that bias in one Jaffe method and two enzymatic methods did not achieve the bias goal at either low or high level of creatinine, indicating they had calibration bias. One enzymatic method failed to achieve all the bias goals in both comparison experiment and recovery test. It is important to understand that both bilirubin interference and calibration traceability to ID-LC/MS should be considered to improve the accuracy of creatinine measurement. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. KDIGO 2012 Clinical Practice Guideline CKD classification rules out creatinine clearance 24 hour urine collection?

    Science.gov (United States)

    Ognibene, A; Grandi, G; Lorubbio, M; Rapi, S; Salvadori, B; Terreni, A; Veroni, F

    2016-01-01

    The recent guideline for the evaluation and management of Chronic Kidney Disease recommends assessing GFR employing equations based on serum creatinine; despite this, creatinine clearance 24-hour urine collection is used routinely in many settings. In this study we compared the classification assessed from CrCl (creatinine clearance 24h urine collection) and e-GFR calculated with CKD-EPI or MDRD formulas. In this retrospective study we analyze consecutive laboratory data: creatinine clearance 24h urine collection, serum creatinine and demographic data such as sex and age from 15,777 patients >18 years of age collected from 2011 to 2013 in our laboratory at Careggi Hospital. The results were then compared to the estimated GFR calculated with the equations according to the recent treatment guidelines. Consecutive and retrospective laboratory data (creatinine clearance 24h urine collection, serum creatinine and, demographic data such as sex and age) from 15,777 patients >18 years of age seen at Careggi Hospital were collected. Comparison between e-GFR calculated with CKD-EPI or MDRD formulas and GFR according CrCl determinations and bias [95% CI] were 11.34 [-47,4/70.1] and 11.4 [-50.2/73] respectively. The concordance for 18/65 years aged group when compared with e-GFR classification between MDRD vs CKDEPI, MDRD vs CrCl and CKD-EPI vs CrCl were 0.78, 0.34, and 0.41 respectively, while in the 65/110years aged group the concordance Kappas were 0.84, 0.38, and 0.36 respectively. The use of CrCl provides a different classification than the estimation of GFR using a prediction equation. The CrCl is unreliable when it is necessary to identify CKD subjects with decrease of GFR of 5ml/min/1.73m(2)/year. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Falsely Elevated Plasma Creatinine Due to an Immunoglobulin M Paraprotein.

    Science.gov (United States)

    McGill, Mitchell R; Vijayan, Anitha; Trulock, Elbert P; Witt, Chad A; Kohler, Giselle D; Scott, Mitchell G

    2016-11-01

    The most common method for measuring plasma creatinine is based on its reaction with picric acid. However, enzymatic methods are becoming more popular due to improved specificity. We present a case of falsely elevated plasma creatinine values obtained by an enzymatic method that turned out to be due to a monoclonal immunoglobulin M (IgM) paraprotein. A 63-year-old woman evaluated for lung transplantation had falsely increased plasma creatinine levels (1.54-1.71mg/dL; corresponding to estimated glomerular filtration rates of 32-36 mL/min/1.73m 2 ) as measured by the Roche Creatinine plus enzymatic assay when compared with the picric acid-based procedure and several other enzymatic methods, which gave plasma creatinine values of 0.7 to 0.8mg/dL. Serum protein electrophoresis revealed an IgM κ light chain paraprotein. Removal of high-molecular-weight (>30kDa) proteins by ultrafiltration reduced the patient's plasma creatinine level by the Roche enzymatic method to 0.7mg/dL. Addition of the patient's immunoglobulin fraction to plasma from other patients with normal plasma creatinine levels resulted in values that were increased by 0.58 to 0.62mg/dL. Furthermore, removal of non-IgM immunoglobulins with protein G-coupled beads did not eliminate the interference from the patient's plasma. Taken together, these studies demonstrate that falsely elevated plasma creatinine values by the Roche enzymatic method can be due to an IgM paraprotein. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  4. Cost and Fuel Efficient SCR-only Solution for post-2010 HD Emission Standards

    NARCIS (Netherlands)

    Cloudt, R.P.M.; Willems, F.P.T.; Heijden, van der P.

    2009-01-01

    A promising SCR-only solution is presented to meetpost-2010 NOx emission targets for heavy dutyapplications. The proposed concept is based on anengine from a EURO IV SCR application, which isconsidered optimal with respect to fuel economy andcosts. The addition of advanced SCR after

  5. Genetic variation at selected SNPs in the leptin gene and association of alleles with markers of kidney disease in a Xhosa population of South Africa.

    Directory of Open Access Journals (Sweden)

    Ikechi G Okpechi

    Full Text Available BACKGROUND: Chronic kidney disease (CKD is a significant public health problem that leads to end-stage renal disease (ESRD with as many as 2 million people predicted to need therapy worldwide by 2010. Obesity is a risk factor for CKD and leptin, the obesity hormone, correlates with body fat mass and markers of renal function. A number of clinical and experimental studies have suggested a link between serum leptin and kidney disease. We hypothesised that variants in the leptin gene (LEP may be associated with markers of CKD in indigenous black Africans. METHODOLOGY/PRINCIPAL FINDINGS: Black South Africans of Xhosa (distinct cultural Bantu-speaking population descent were recruited for the study and four common polymorphisms of the LEP (rs7799039, rs791620, rs2167270 and STS-U43653 [ENSSNP5824596] were analysed for genotype and haplotype association with urine albumin-to-creatinine ratio (UACR, estimated glomerular filtration rate (eGFR, Serum creatinine (Scr and serum leptin level. In one of the four single nucleotide polymorphisms (SNPs we examined, an association with the renal phenotypes was observed. Hypertensive subjects with the T allele (CT genotype of the ENSSNP5824596 SNP had a significantly higher eGFR (p = 0.0141, and significantly lower Scr (p = 0.0137. This was confirmed by haplotype analysis. Also, the haplotype GAAC had a modest effect on urine albumin-to-creatinine ratio in normotensive subjects (p = 0.0482. CONCLUSIONS/SIGNIFICANCE: These results suggest that genetic variations of the LEP may be associated with phenotypes that are markers of CKD in black Africans.

  6. Creatinine

    Science.gov (United States)

    ... to affect the kidneys, such as diabetes or high blood pressure , then creatinine and BUN tests may be used to monitor ... the ribs, near where the kidneys are located High blood pressure The creatinine blood test may be ordered, along with a ...

  7. Evaluation of Mercury Emissions from Coal-Fired Facilities with SCR and FGD Systems

    Energy Technology Data Exchange (ETDEWEB)

    J. A. Withum; S. C. Tseng; J. E. Locke

    2006-01-31

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NO{sub x}, and SO{sub 2} control technologies. It is expected that these data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of SCR catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the ninth in a series of topical reports, describes the results and analysis of mercury sampling performed on Unit 1 at Plant 7, a 566 MW unit burning a bituminous coal containing 3.6% sulfur. The unit is equipped with a SCR, ESP, and wet FGD to control NO{sub x}, particulate, and SO

  8. Creatinine, diet, micronutrients, and arsenic methylation in West Bengal, India.

    Science.gov (United States)

    Basu, Arin; Mitra, Soma; Chung, Joyce; Guha Mazumder, D N; Ghosh, Nilima; Kalman, David; von Ehrenstein, Ondine S; Steinmaus, Craig; Liaw, Jane; Smith, Allan H

    2011-09-01

    Ingested inorganic arsenic (InAs) is methylated to monomethylated (MMA) and dimethylated metabolites (DMA). Methylation may have an important role in arsenic toxicity, because the monomethylated trivalent metabolite [MMA(III)] is highly toxic. We assessed the relationship of creatinine and nutrition--using dietary intake and blood concentrations of micronutrients--with arsenic metabolism, as reflected in the proportions of InAS, MMA, and DMA in urine, in the first study that incorporated both dietary and micronutrient data. We studied methylation patterns and nutritional factors in 405 persons who were selected from a cross-sectional survey of 7,638 people in an arsenic-exposed population in West Bengal, India. We assessed associations of urine creatinine and nutritional factors (19 dietary intake variables and 16 blood micronutrients) with arsenic metabolites in urine. Urinary creatinine had the strongest relationship with overall arsenic methylation to DMA. Those with the highest urinary creatinine concentrations had 7.2% more arsenic as DMA compared with those with low creatinine (p creatinine concentration was the strongest biological marker of arsenic methylation efficiency, and therefore should not be used to adjust for urine concentration in arsenic studies. The new finding that animal fat intake has a positive relationship with MMA% warrants further assessment in other studies. Increased MMA% was also associated, to a lesser extent, with low serum selenium and folate.

  9. The energy consumption and environmental impacts of SCR technology in China

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Zengying; Ma, Xiaoqian; Lin, Hai; Tang, Yuting [School of Electric Power, Guangdong Key Laboratory of Clean Energy Technology, South China University of Technology, Guangzhou 510640 (China)

    2011-04-15

    Energy and environment are drawing greater attention today, particularly with the rapid development of the economy and increase consumption of energy in China. At present, coal-fired power plants are mainly responsible for atmospheric air pollution. The selective catalytic reduction (SCR) technology is a highly effective method for NO{sub X} control. The present study identified and quantified the energy consumption and the environmental impacts of SCR system throughout the whole life cycle, including production and transportation of manufacturing materials, installation and operation of SCR technology. The analysis was conducted with the utilization of life cycle assessment (LCA) methodology which provided a quantitative basis for assessing potential improvements in the environmental performance of the system. The functional unit of the study was 5454 t NO{sub X} emission from an existing Chinese pulverized coal power plant for 1 year. The current study compared life cycle emissions from two types of de-NO{sub X} technologies, namely the SCR technology and the selective non-catalytic reduction (SNCR) technology, and the case that NO{sub X} was emitted into atmosphere directly. The results showed that the environmental impact loading resulting from SCR technology (66810 PET{sub 2000}) was smaller than that of flue gas emitted into atmosphere directly (164121 PET{sub 2000}) and SNCR technology (105225 PET{sub 2000}). More importantly, the SCR technology is much more effective at the elimination of acidification and nutrient enrichment than SNCR technology and the case that NO{sub X} emitted into atmosphere directly. This SCR technology is more friendly to the environment, and can play an important role in NO{sub X} control for coal-fired power plants as well as industrial boilers. (author)

  10. Effect of atorvastatin on preventing contrast-induced nephropathy

    International Nuclear Information System (INIS)

    Zhang Dongya; Zhu Jing; Chen Jianchang; Xu Weiting; Luo Xiaoyu; Zhao Liangping

    2011-01-01

    Objective: To study the effects of atorvastatin on contrast-induced renal function and urinary protein change in patients undergoing diagnostic and therapeutic coronary intervention. Methods: Two hundred and forty-six patients who underwent coronary angiography or percutaneous coronary intervention (PCI) were randomized to receive atorvastatin (40 mg, qn, n=123) or no atorvastatin (n=123) treatment 3 days before coronary angiography. All patients received hydrated therapy. Serum creatinine (Scr), urinary αl-microglobulin (α l -MG), and urinary albumin (mALB) were checked for evidence of tubular or glomerular damage at start, and 36 to 48 hours after the administration of a radiocontrast agent. High-sensitive C-reactive protein (hsCRP) levels, urinary α l -MG/ urinary creatinine(Ucr) and mALB/ Ucr were also assessed at the same time. Creatinine clearance(Ccr) was calculated according to Cockcroft-Gault formulas basing on serum creatinine. Results: (1) In the control group and atorvastatin-treated group, comparison with the value before coronary angiography or PCI, urinary α l -MG/ Ucr, mALB/ Ucr, Scr and hsCRP significantly increased from 36 to 48 hours after angiography or PCI (P l -MG/ Ucr significantly increased at the 2nd day after angiography or PCI in the control group (P<0.05), incidence of contrast induced nephropathy (CIN) significantly increased too (8.13% vs 0.81%, P<0.05). Conclusions: Contrast media induces light renal function damage. Pretreatment with atorvastatin 40 mg/qn for 3 days could significantly reduce procedural inflammatory reaction and prevent contrast-induced nephropathy. (authors)

  11. Can baseline serum creatinine and e-GFR predict renal function outcome after augmentation cystoplasty in children?

    Science.gov (United States)

    Singh, Prempal; Bansal, Ankur; Sekhon, Virender; Nunia, Sandeep; Ansari, M S

    2018-01-01

    To assess cut-off value of creatinine and glomerular filtration rate for augmentation cystoplasty (AC) in paediatric age-group. Data of all paediatric-patients (Creatinine and e-GFR were assessed at the time of surgery, at 6 months and at last follow-up. Renal function deterioration was defined as increase in creatinine by ≥25% from baseline value or new-onset stage-3 CKD or worsening of CKD stage with pre-operative-CKD stage-3. ROCs were plotted using creatinine and e-GFR for AC. A total of 94 patients with mean-age 8.9 years were included. The mean creatinine and e-GFR were 1.33mg/dL and 57.68mL/min respectively. Out of 94 patients, AC was performed in 45 patients and in the remaining 49 patients AC was not done (control-group), as they were not willing for the same. Baseline patient's characteristics were comparable in both Groups. 22 underwent gastro-cystoplasty (GC) and 25 underwent ileo-cystoplasty (IC). Decline in renal function was observed in 15 (33.3%) patients of AC-group and in 31 (63.3%) patients of control-group. Patients having creatinine ≥1.54mg/dL (P=0.004, sensitivity (S) 63.6% and specificity (s) 90.5%) at baseline and e-GFR ≤46mL/min (P=0.000, S=100% and s=85.7%) at the time of surgery had significantly increased probability of renal function deterioration on follow-up after AC. e-GFR ≤46mL/min and creatinine ≥1.54mg/dL at time of surgery could serve as a predictor of renal function deterioration in AC in paediatric patients. Copyright® by the International Brazilian Journal of Urology.

  12. LPV gain-scheduled control of SCR aftertreatment systems

    Science.gov (United States)

    Meisami-Azad, Mona; Mohammadpour, Javad; Grigoriadis, Karolos M.; Harold, Michael P.; Franchek, Matthew A.

    2012-01-01

    Hydrocarbons, carbon monoxide and some of other polluting emissions produced by diesel engines are usually lower than those produced by gasoline engines. While great strides have been made in the exhaust aftertreatment of vehicular pollutants, the elimination of nitrogen oxide (NO x ) from diesel vehicles is still a challenge. The primary reason is that diesel combustion is a fuel-lean process, and hence there is significant unreacted oxygen in the exhaust. Selective catalytic reduction (SCR) is a well-developed technology for power plants and has been recently employed for reducing NO x emissions from automotive sources and in particular, heavy-duty diesel engines. In this article, we develop a linear parameter-varying (LPV) feedforward/feedback control design method for the SCR aftertreatment system to decrease NO x emissions while keeping ammonia slippage to a desired low level downstream the catalyst. The performance of the closed-loop system obtained from the interconnection of the SCR system and the output feedback LPV control strategy is then compared with other control design methods including sliding mode, and observer-based static state-feedback parameter-varying control. To reduce the computational complexity involved in the control design process, the number of LPV parameters in the developed quasi-LPV (qLPV) model is reduced by applying the principal component analysis technique. An LPV feedback/feedforward controller is then designed for the qLPV model with reduced number of scheduling parameters. The designed full-order controller is further simplified to a first-order transfer function with a parameter-varying gain and pole. Finally, simulation results using both a low-order model and a high-fidelity and high-order model of SCR reactions in GT-POWER interfaced with MATLAB/SIMULINK illustrate the high NO x conversion efficiency of the closed-loop SCR system using the proposed parameter-varying control law.

  13. Comparative study of three methods of estimation of creatinine clearance in critically ill patients.

    Science.gov (United States)

    Blasco, V; Antonini, F; Zieleskiewicz, L; Hammad, E; Albanèse, J; Martin, C; Leone, M

    2014-05-01

    At the bedside, the reference method for creatinine clearance determination is based on the measurement of creatinine concentrations in urine and serum (mCrCl). Several models are available to calculate the creatinine clearance from the serum creatinine concentration. This observational survey aimed at testing the hypothesis that the proposed equations are unreliable to determine accurate creatinine clearance in patients admitted to intensive care unit (ICU). Creatinine clearance was determined by the use of mCrCl. Then, we compared three equations: Cockcroft-Gault (CG), Simplified Modification of Diet in Renal Disease (MDRDs), and Chronic Kidney Disease Epidemiology (CKD-EPI) in 156 consecutive patients within the first 24hours after ICU admission. We tested the hypothesis that the three equations were equivalent. The agreement between the three equations was evaluated by linear regression and Bland and Altman analysis. Bland and Altman analysis showed similar agreement between the three equations. The biases and precisions were -4.8±51, -1.3±50, and 8.2±44 for CG, MDRDs, and CKD-EPI equations, respectively (P>0.05). The precisions were similar for the three equations (P>0.05). The percentages of outliers at ±30% were 44%, 45%, and 49% for CG, MDRDs, and CKD-EPI, respectively (P>0.05). Regarding the high percentage of outliers, the use of these equations cannot be recommended in ICU patients. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  14. Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group.

    Science.gov (United States)

    Delanghe, Joris R; Cobbaert, Christa; Galteau, Marie-Madeleine; Harmoinen, Aimo; Jansen, Rob; Kruse, Rolf; Laitinen, Päivi; Thienpont, Linda M; Wuyts, Birgitte; Weykamp, Cas; Panteghini, Mauro

    2008-01-01

    The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are described, in which 189 European laboratories analyzed serum creatinine in a commutable serum-based material, using analytical systems from seven companies. Values were targeted using isotope dilution gas chromatography/mass spectrometry. Results were tested on their compliance to a set of three criteria: trueness, i.e., no significant bias relative to the target value, between-laboratory variation and within-laboratory variation relative to the maximum allowable error. For the lower and intermediate level, values differed significantly from the target value in the Jaffe and the dry chemistry methods. At the high level, dry chemistry yielded higher results. Between-laboratory coefficients of variation ranged from 4.37% to 8.74%. Total error budget was mainly consumed by the bias. Non-compensated Jaffe methods largely exceeded the total error budget. Best results were obtained for the enzymatic method. The dry chemistry method consumed a large part of its error budget due to calibration bias. Despite the European IVD directive and the growing needs for creatinine standardization, an unacceptable inter-laboratory variation was observed, which was mainly due to calibration differences. The calibration variation has major clinical consequences, in particular in pediatrics, where reference ranges for serum and plasma creatinine are low, and in the estimation of glomerular filtration rate.

  15. Functional characterization of sucrose phosphorylase and scrR, a regulator of sucrose metabolism in Lactobacillus reuteri.

    Science.gov (United States)

    Teixeira, Januana S; Abdi, Reihaneh; Su, Marcia Shu-Wei; Schwab, Clarissa; Gänzle, Michael G

    2013-12-01

    Lactobacillus reuteri harbours alternative enzymes for sucrose metabolism, sucrose phosphorylase, fructansucrases, and glucansucrases. Sucrose phosphorylase and fructansucrases additionally contribute to raffinose metabolism. Glucansucrases and fructansucrases produce exopolysaccharides as alternative to sucrose hydrolysis. L. reuteri LTH5448 expresses a levansucrase (ftfA) and sucrose phosphorylase (scrP), both are inducible by sucrose. This study determined the contribution of scrP to sucrose and raffinose metabolism in L. reuteri LTH5448, and elucidated the role of scrR in regulation sucrose metabolism. Disruption of scrP and scrR was achieved by double crossover mutagenesis. L. reuteri LTH5448, LTH5448ΔscrP and LTH5448ΔscrR were characterized with respect to growth and metabolite formation with glucose, sucrose, or raffinose as sole carbon source. Inactivation of scrR led to constitutive transcription of scrP and ftfA, demonstrating that scrR is negative regulator. L. reuteri LTH5448 and the LTH5448ΔscrP or LTH5448ΔscrR mutant strains did not differ with respect to glucose, sucrose or raffinose utilization. However, L. reuteri LTH5448ΔscrP produced more levan, indicating that the lack of sucrose phosphorylase is compensated by an increased metabolic flux through levansucrase. In conclusion, the presence of alternate pathways for sucrose and raffinose metabolism and their regulation indicate that these substrates, which are abundant in plants, are preferred carbohydrate sources for L. reuteri. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Cost and fuel efficient SCR-only solution for post-2010 HD emission standards

    NARCIS (Netherlands)

    Cloudt, R.P.M.; Willems, F.P.T.; Heijden, P.V.A.M. van der

    2009-01-01

    A promising SCR-only solution is presented to meet post-2010 NOx emission targets for heavy duty applications. The proposed concept is based on an engine from a EURO IV SCR application, which is considered optimal with respect to fuel economy and costs. The addition of advanced SCR after treatment

  17. The Relationship between Serum Hemoglobin and Creatinine Levels and Intra-Hospital Mortality and Morbidity in Acute Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Afsoon Fazlinezhad

    2014-09-01

    Full Text Available Background: Studies have shown that Glomerular Filtration Rate (GFR and Hemoglobin (Hb concentrations are two predictive values for ST-elevation Myocardial Infarction (MI mortality.. Objectives: This study aimed to investigate the relationship between GFR and Hb concentrations and intra-hospital mortality and electrocardiographic (ECG and echocardiographic abnormalities in ST-elevation MI patients admitted to a highly equipped hospital in Mashhad. The results will help define some factors to manage these patients more efficiently.. Patients and Methods: This descriptive study aimed to assess the relationship between Hb and GFR concentrations and mortality and morbidity among 294 randomly selected patients with ST-elevation MI. Echocardiography, ECG, and routine laboratory tests, including Hb and creatinine, were performed for all the patients. Then, the data were entered into the SPSS statistical software, version 16 and were analyzed using chi-square, t-test, and ANOVA. P < 0.05 was considered as statistically significant.. Results: Intra-hospital mortality rate was 10.5%. Besides, the results showed higher levels of serum blood sugar (P < 0.001, higher levels of creatinine (P < 0.001, lower levels of GFR (P < 0.001, lower ejection fraction (P < 0.001, higher grades of left ventricular diastolic dysfunction (P = 0.002, and lower mean Hb concentration (P = 0.022 in the dead compared to the alive cases. Besides, the patients with mechanical complications had lower Hb levels (P = 0.008. The results showed no significant relationship between creatinine level and mechanical and electrical complications (P = 0.430 and P = 0.095, respectively. However, ejection fraction was significantly associated with GFR (P = 0.016.. Conclusions: According to the results, low levels of Hb and GFR could predict mortality caused by ST-elevation MI and ECG abnormalities could notify intra-hospital death. Moreover, lower Hb levels were associated with mechanical

  18. A review on creatinine measurement techniques.

    Science.gov (United States)

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Cystatin C versus Creatinine in Determining Risk Based on Kidney Function

    NARCIS (Netherlands)

    Shlipak, Michael G.; Matsushita, Kunihiro; Arnlov, Johan; Inker, Lesley A.; Katz, Ronit; Polkinghorne, Kevan R.; Rothenbacher, Dietrich; Sarnak, Mark J.; Astor, Brad C.; Coresh, Josef; Levey, Andrew S.; Gansevoort, Ron T.

    2013-01-01

    BACKGROUND Adding the measurement of cystatin C to that of serum creatinine to determine the estimated glomerular filtration rate (eGFR) improves accuracy, but the effect on detection, staging, and risk classification of chronic kidney disease across diverse populations has not been determined.

  20. Evaluation of estimated creatinine clearance before steady state in acute kidney injury by creatinine kinetics.

    Science.gov (United States)

    Yashiro, Masatomo; Ochiai, Miyuki; Fujisawa, Nao; Kadoya, Yuko; Kamata, Tadashi

    2012-08-01

    A simple method to calculate estimated creatinine clearance using two serum creatinine concentration (Cr) values in acute kidney injury (AKI) was developed (eCrCl-AKI). We aimed to evaluate its accuracy and to clarify its contribution to the classification of AKI. We validated the errors in eCrCl-AKI in a simulation study after various reductions in creatinine clearance (CrCl) at various levels of chronic kidney disease (CKD). We compared the eCrCl-AKI-based classification of RIFLE criteria with the Cr-based classification or that proposed by Waikar and Bonventre. The regression equations of eCrCl-AKI on time were determined and Cr values were reconstructed by creatinine kinetics substituting CrCl with eCrCl-AKI in actual patients. Most errors in eCrCl-AKI were relatively small (from -13.6 to +7.9%) with the exception of two Cr values that straddled the changing trend of Cr. The classification according to RIFLE criteria based on Cr was unstable and did not enable adequate classification, especially in milder reductions of CrCl with advanced CKD. The classification based on eCrCl-AKI was stable and enabled adequate classification. There were good agreements between measured Cr and reconstructed Cr with eCrCl-AKI. The regression equations of eCrCl-AKI revealed changes of renal function that were unexpected only from fluctuations of Cr. eCrCl-AKI can provide relatively accurate estimates for fluctuating CrCl. eCrCl-AKI enables more stable and earlier classification of AKI than Cr, at least in the simulation study. The more widespread use of eCrCl-AKI in actual clinical settings of AKI is necessary to evaluate this formula.

  1. Evaluation of Mercury Emissions from Coal-Fired Facilities with SCR and FGD Systems

    Energy Technology Data Exchange (ETDEWEB)

    J. A. Withum; J. E. Locke

    2006-02-01

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NO{sub x}, and SO{sub 2} control technologies. It is expected that this data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of SCR catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the tenth in a series of topical reports, describes the results and analysis of mercury sampling performed on two 468 MW units burning bituminous coal containing 1.3-1.7% sulfur. Unit 2 is equipped with an SCR, ESP, and wet FGD to control NO{sub x}, particulate, and SO{sub 2} emissions

  2. Requirement for specific gravity and creatinine adjustments for urinary steroids and luteinizing hormone concentrations in adolescents.

    Science.gov (United States)

    Singh, Gurmeet K S; Balzer, Ben W R; Desai, Reena; Jimenez, Mark; Steinbeck, Katharine S; Handelsman, David J

    2015-11-01

    Urinary hormone concentrations are often adjusted to correct for hydration status. We aimed to determine whether first morning void urine hormones in growing adolescents require adjustments and, if so, whether urinary creatinine or specific gravity are better adjustments. The study population was adolescents aged 10.1 to 14.3 years initially who provided fasting morning blood samples at 0 and 12 months (n = 343) and first morning urine every three months (n = 644). Unadjusted, creatinine and specific gravity-adjusted hormonal concentrations were compared by Deming regression and Bland-Altman analysis and grouped according to self-rated Tanner stage or chronological age. F-ratios for self-rated Tanner stages and age groups were used to compare unadjusted and adjusted hormonal changes in growing young adolescents. Correlations of paired serum and urinary hormonal concentration of unadjusted and creatinine and specific gravity-adjusted were also compared. Fasting first morning void hormone concentrations correlated well and were unbiased between unadjusted or adjusted by either creatinine or specific gravity. Urine creatinine concentration increases with Tanner stages, age and male gender whereas urine specific gravity was not influenced by Tanner stage, age or gender. Adjustment by creatinine or specific gravity of urinary luteinizing hormone, estradiol, testosterone, dihydrotestosterone and dehydroepiandrosterone concentrations did not improve correlation with paired serum concentrations. Urine steroid and luteinizing hormone concentrations in first morning void samples of adolescents are not significantly influenced by hydration status and may not require adjustments; however, if desired, both creatinine and specific gravity adjustments are equally suitable. © The Author(s) 2015.

  3. Simulation and Optimization of SCR System for Direct-injection Diesel Engine

    Directory of Open Access Journals (Sweden)

    Guanqiang Ruan

    2014-11-01

    Full Text Available The turbo diesel SCR system has been researched and analyzed in this paper. By using software of CATIA, three-dimensional physical model of SCR system has been established, and with software of AVL-FIRE, the boundary conditions have been set, simulated and optimized. In the process of SCR system optimizing, it mainly optimized the pray angle. Compare the effects of processing NO to obtain batter optimization results. At last the optimization results are compared by bench test, and the experimental results are quite consistent with simulation.

  4. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    Science.gov (United States)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of

  5. A validated LC-MS/MS method for the quantitative measurement of creatinine as an endogenous biomarker in human plasma.

    Science.gov (United States)

    Zhao, Yue; Liu, Guowen; Angeles, Aida; Christopher, Lisa J; Wang, Zhaoqing; Arnold, Mark E; Shen, Jim X

    2016-10-01

    Creatinine is an endogenous compound generated from creatine by normal muscular metabolism. It is an important indicator of renal function and the serum level is routinely monitored in clinical labs. Results & methodology: Surrogate analyte (d3-creatinine) was used for calibration standard and quality control preparation and the relative instrument response ratio between creatinine and d3-creatinine was used to calculate the endogenous creatinine concentrations. A fit-for-purpose strategy of using a surrogate analyte and authentic matrix was adopted for this validation. The assay was the first human plasma assay using such strategy and was successfully applied to a clinical study to confirm a transient elevation of creatinine observed using an existing clinical assay.

  6. Creatinine urine test

    Science.gov (United States)

    Urine creatinine test ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ... done to see how well your kidneys work. Creatinine is removed by the body entirely by the ...

  7. Alternative SILP-SCR Catalysts based on Guanidinium Chromates

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes; Riisager, Anders; Ståhl, Kenny

    There is an increasing global concern about human caused emissions of pollutants like sulfur and nitrogen oxides to the atmosphere leading to, e.g. smog and acid rain damaging to the human health and the environment. Selective catalytic reduction (SCR) of NOx with ammonia as reductant is the most...... duct. There is therefore a demand for alkali-resistant SCR catalysts more flexible regarding temperature of operation and position in the duct. Supported ionic liquid phase (SILP) catalysts with 1,1,3,3-Tetramethylguanidinium (TMGH+) and a chromium oxide anion supported on anatase have exhibited...

  8. Association between serum interleukin-6 and serum 3,5,3'-triiodothyronine in nonthyroidal illness

    NARCIS (Netherlands)

    Boelen, A.; Platvoet-ter Schiphorst, M. C.; Wiersinga, W. M.

    1993-01-01

    Increased serum concentrations of FFA, bilirubin, and carboxyl-methyl-propyl-furanpropionic acid, accumulating in chronic renal failure in direct relationship with serum creatinine, have all been implicated in the pathogenesis of the low T3 syndrome during illness. Cytokines may also be involved in

  9. Creatinine sensor based on a molecularly imprinted polymer-modified hanging mercury drop electrode.

    Science.gov (United States)

    Lakshmi, Dhana; Prasad, Bhim Bali; Sharma, Piyush Sindhu

    2006-09-15

    Molecularly imprinted polymers (MIP) have been elucidated to work as artificial receptors. In our present study, a MIP was applied as a molecular recognition element to a chemical sensor. We have constructed a creatinine sensor based on a MIP layer selective for creatinine and its differential pulse, cathodic stripping voltammetric detection (DPCSV) on a hanging mercury drop electrode (HMDE). The creatinine sensor was fabricated by the drop coating of dimethylformamide (DMF) solution of a creatinine-imprinted polymer onto the surface of HMDE. The modified-HMDE, preanodised in neutral medium at +0.4V versus Ag/AgCl for 120s, exhibited a marked enhancement in DPCSV current in comparison to the less anodised (creatinine was preconcentrated and instantaneously oxidised in MIP layer giving DPCSV response in the concentration range of 0.0025-84.0mugmL(-1) [detection limit (3sigma) 1.49ngmL(-1)]. The sensor was found to be highly selective for creatinine without any response of interferents viz., NaCl, urea, creatine, glucose, phenylalanine, tyrosine, histidine and cytosine. The non-imprinted polymer-modified electrode did not show linear response to creatinine. The imprinting factor as high as 9.4 implies that the imprinted polymer exclusively acts as a recognition element of creatinine sensor. The proposed procedure can be used to determine creatinine in human blood serum without any preliminary treatment of the sample in an accurate, rapid and simple way.

  10. Amyotrophic lateral sclerosis outcome measures and the role of albumin and creatinine: a population-based study.

    Science.gov (United States)

    Chiò, Adriano; Calvo, Andrea; Bovio, Giacomo; Canosa, Antonio; Bertuzzo, Davide; Galmozzi, Francesco; Cugnasco, Paolo; Clerico, Marinella; De Mercanti, Stefania; Bersano, Enrica; Cammarosano, Stefania; Ilardi, Antonio; Manera, Umberto; Moglia, Cristina; Sideri, Riccardo; Marinou, Kalliopi; Bottacchi, Edo; Pisano, Fabrizio; Cantello, Roberto; Mazzini, Letizia; Mora, Gabriele

    2014-09-01

    There is an urgent need to identify reliable biomarkers of amyotrophic lateral sclerosis (ALS) progression for clinical practice and pharmacological trials. To correlate several hematological markers evaluated at diagnosis with ALS outcome in a population-based series of patients (discovery cohort) and replicate the findings in an independent validation cohort from an ALS tertiary center. The discovery cohort included 712 patients with ALS from the Piemonte and Valle d'Aosta Register for Amyotrophic Lateral Sclerosis from January 1, 2007, to December 31, 2011. The validation cohort comprised 122 patients with ALS at different stages of disease consecutively seen at an ALS tertiary center between January 1, 2007, and January 1, 2009. The following hematological factors were investigated and correlated with survival: total leukocytes, neutrophils, lymphocytes, monocytes, glucose, creatinine, uric acid, albumin, bilirubin, total cholesterol, triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, creatine kinase, thyroid-stimulating hormones, and erythrocyte sedimentation rate; all analyses were performed separately by sex. The patient of the validation cohort also underwent bioelectrical impedance analysis for the calculation of fat-free mass. Of the 712 patients in the examined period in Piemonte and Valle d'Aosta, 638 (89.6%) were included in the study. Only serum albumin (men: ≤ 4.3 vs >4.3 mg/dL, P 4.3 mg/dL, P creatinine levels (men: ≤ 0.82 vs >0.82 mg/dL, P = .004; women: ≤ 0.65 vs >0.05 mg/dL, P = .004) and lymphocyte count (men: ≤ 1700 vs >1700/μL, P = .04; women: ≤ 1700 vs >1700/μL, P = .02) were significantly associated with ALS outcome in both sexes with a dose-response effect (better survival with increasing levels). These findings were confirmed in the validation cohort. Multivariable analysis showed that serum albumin (men: hazard ratio [HR], 1.39; 95% CI, 1.05-1.90; P = .02; women: HR, 1.73; 95

  11. Use of Multiple Imputation Method to Improve Estimation of Missing Baseline Serum Creatinine in Acute Kidney Injury Research

    Science.gov (United States)

    Peterson, Josh F.; Eden, Svetlana K.; Moons, Karel G.; Ikizler, T. Alp; Matheny, Michael E.

    2013-01-01

    Summary Background and objectives Baseline creatinine (BCr) is frequently missing in AKI studies. Common surrogate estimates can misclassify AKI and adversely affect the study of related outcomes. This study examined whether multiple imputation improved accuracy of estimating missing BCr beyond current recommendations to apply assumed estimated GFR (eGFR) of 75 ml/min per 1.73 m2 (eGFR 75). Design, setting, participants, & measurements From 41,114 unique adult admissions (13,003 with and 28,111 without BCr data) at Vanderbilt University Hospital between 2006 and 2008, a propensity score model was developed to predict likelihood of missing BCr. Propensity scoring identified 6502 patients with highest likelihood of missing BCr among 13,003 patients with known BCr to simulate a “missing” data scenario while preserving actual reference BCr. Within this cohort (n=6502), the ability of various multiple-imputation approaches to estimate BCr and classify AKI were compared with that of eGFR 75. Results All multiple-imputation methods except the basic one more closely approximated actual BCr than did eGFR 75. Total AKI misclassification was lower with multiple imputation (full multiple imputation + serum creatinine) (9.0%) than with eGFR 75 (12.3%; Pcreatinine) (15.3%) versus eGFR 75 (40.5%; P<0.001). Multiple imputation improved specificity and positive predictive value for detecting AKI at the expense of modestly decreasing sensitivity relative to eGFR 75. Conclusions Multiple imputation can improve accuracy in estimating missing BCr and reduce misclassification of AKI beyond currently proposed methods. PMID:23037980

  12. Early serum creatinine changes and outcomes in patients admitted for acute heart failure: the cardio-renal syndrome revisited.

    Science.gov (United States)

    Núñez, Julio; Garcia, Sergio; Núñez, Eduardo; Bonanad, Clara; Bodí, Vicent; Miñana, Gema; Santas, Enrique; Escribano, David; Bayes-Genis, Antonio; Pascual-Figal, Domingo; Chorro, Francisco J; Sanchis, Juan

    2017-08-01

    The changes in renal function that occurred in patients with acute decompensated heart failure (ADHF) are prevalent, and have multifactorial etiology and dissimilar prognosis. To what extent the prognostic role of such changes may vary according to the presence of renal insufficiency at admission is not clear. Accordingly, we sought to determine whether early creatinine changes (ΔCr) (admission to 48-72 hours) had an effect on 1-year mortality relative to the presence of renal insufficiency at admission. We included 705 consecutive patients admitted with the diagnosis of ADHF. Admission renal insufficiency was defined as serum creatinine ≥1.4mg/dl (A-RI cr ) or estimated glomerular filtration rate renal insufficiency (24.7% and 42.8% for A-RIcr and A-RIGFR, respectively) had higher prevalence of extreme values in ΔCr in either direction (increasing/decreasing). At 1-year follow-up, 114 (16.2%) deaths were registered. The multivariable analysis showed a significant interaction between admission renal insufficiency and ΔCr ( p=0.004 and p=0.019 for A-RIcr and A-RIGFR, respectively). In the presence of renal insufficiency, the continuum of ΔCr followed a positive and almost linear relationship with mortality risk. Conversely, in patients without renal insufficiency, those changes adopted a 'J-shape' trajectory with increased mortality at both ends of the curve distribution. In patients with ADHF the effect of ΔCr on 1-year mortality varied according to its magnitude and the presence of admission renal insufficiency. There was a graded-association with mortality when renal insufficiency was present on admission.

  13. Mordenite - Type Zeolite SCR Catalysts with Iron or Copper

    DEFF Research Database (Denmark)

    2012-01-01

    Cu/mordenite catalysts were found to be highly active for the SCR of NO with NH3 and exhibited high resistance to alkali poisoning. Redox and acidic properties of Cu/mordenite were well preserved after poisoning with potassium unlike that of vanadium catalysts. Fe-mordenite catalysts also reveale...... to be essential requirements for the high alkali resistance. Mordenite-type zeolite based catalysts could therefore be attractive alternatives to conventional SCR catalysts for biomass fired power plant flue gas treatment....

  14. Comparison of Glomerular Filtration Rate Estimation from Serum Creatinine and Cystatin C in HNF1A-MODY and Other Types of Diabetes

    Directory of Open Access Journals (Sweden)

    Magdalena Szopa

    2015-01-01

    Full Text Available Introduction. We previously showed that in HNF1A-MODY the cystatin C-based glomerular filtration rate (GFR estimate is higher than the creatinine-based estimate. Currently, we aimed to replicate this finding and verify its clinical significance. Methods. The study included 72 patients with HNF1A-MODY, 72 with GCK-MODY, 53 with type 1 diabetes (T1DM, 70 with type 2 diabetes (T2DM, and 65 controls. Serum creatinine and cystatin C levels were measured. GFR was calculated from creatinine and cystatin C using the CKD-EPI creatinine equation (eGRF-cr and CKD-EPI cystatin C equation (eGFR-cys, respectively. Results. Cystatin C levels were lower (p<0.001 in the control (0.70±0.13 mg/L, HNF1A (0.75±0.21, and GCK (0.72±0.16 mg/L groups in comparison to those with either T1DM (0.87±0.15 mg/L or T2DM (0.9±0.23 mg/L. Moreover, eGFR-cys was higher than eGRF-cr in HNF1A-MODY, GCK-MODY, and the controls (p=0.004; p=0.003; p<0.0001. This corresponded to 8.9 mL/min/1.73 m2, 9.7 mL/min/1.73 m2, and 16.9 mL/min/1.73 m2 of difference. Additionally, T1DM patients had higher eGFR-cr than eGFR-cys (11.6 mL/min/1.73 m2; p=0.0004; no difference occurred in T2DM (p=0.91. Conclusions. We confirmed that eGFR-cys values in HNF1A-MODY patients are higher compared to eGFR-cr. Some other differences were also described in diabetic groups. However, none of them appears to be clinically relevant.

  15. The influence of a cooked meat meal on creatinine plasma concentration and creatinine clearance.

    OpenAIRE

    Mayersohn, M; Conrad, K A; Achari, R

    1983-01-01

    1 The influence of a meal containing cooked meat (225 g) on creatinine plasma concentration, creatinine urinary excretion and creatinine clearance was determined in six healthy male subjects. 2 The meat meal produced an average 52% increase in creatinine plasma concentration within 1.5 to 3.5 h after ingestion. The 24 h area under the creatinine plasma concentration-time curve increased by about 19%. Urinary creatinine excretion during 24 h increased by an average of 13%. Creatinine clearance...

  16. The effects of soy protein on chronic kidney disease: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Zhang, J; Liu, J; Su, J; Tian, F

    2014-09-01

    There is a growing body of evidence to indicate that soy protein consumption may have a beneficial effect on kidney function. We performed a meta-analysis to evaluate the effects of soy protein consumption compared with animal protein consumption in patients with pre-dialysis chronic kidney disease (CKD). We conducted a structured electronic search of the databases PubMed, EMBASE, Cochrane Library and Chinese Biological Medicine for randomized controlled trials published up to March 2014. The outcome measures were serum creatinine (SCR), triglyceride (TG), total cholesterol (TC), calcium (Ca) and phosphorus concentrations. Weighted or standard mean differences were calculated for net changes using random-effects models. The meta-analysis consisted of nine trials, comprising 197 subjects. Soy protein intake significantly reduced SCR and serum phosphorus concentrations. The mean difference was -6.231 μmol/l (95% confidence interval (CI): -11.109, -1.352 μmol/l) for SCR (P=0.012) and -0.804 (95% CI: -1.143, -0.464 μmol/l) for serum phosphorus (P=0.00). It also significantly reduced serum TG, with a pooled estimated change of -0.223 mmol/l (95% CI: -0.396, -0.051 mmol/l; P=0.011) after the exclusion of one trial indicated by sensitivity analyses. No statistically significant effects were observed for TC (-0.135 mmol/l (95% CI: -0.289, 0.019 mmol/l)) or Ca (0.023 mmol/l (95% CI: -0.016, 0.062 mmol/l)). The meta-analysis suggested a protective effect of soy protein consumption on SCR and serum phosphorus concentrations in pre-dialysis CKD patients. It may also have a significant effect on lowering serum TG concentrations. However, nonsignificant effects on TC and Ca were observed. Evidence was limited because of the relatively small number of available trials and subjects.

  17. The description of a method for accurately estimating creatinine clearance in acute kidney injury.

    Science.gov (United States)

    Mellas, John

    2016-05-01

    Acute kidney injury (AKI) is a common and serious condition encountered in hospitalized patients. The severity of kidney injury is defined by the RIFLE, AKIN, and KDIGO criteria which attempt to establish the degree of renal impairment. The KDIGO guidelines state that the creatinine clearance should be measured whenever possible in AKI and that the serum creatinine concentration and creatinine clearance remain the best clinical indicators of renal function. Neither the RIFLE, AKIN, nor KDIGO criteria estimate actual creatinine clearance. Furthermore there are no accepted methods for accurately estimating creatinine clearance (K) in AKI. The present study describes a unique method for estimating K in AKI using urine creatinine excretion over an established time interval (E), an estimate of creatinine production over the same time interval (P), and the estimated static glomerular filtration rate (sGFR), at time zero, utilizing the CKD-EPI formula. Using these variables estimated creatinine clearance (Ke)=E/P * sGFR. The method was tested for validity using simulated patients where actual creatinine clearance (Ka) was compared to Ke in several patients, both male and female, and of various ages, body weights, and degrees of renal impairment. These measurements were made at several serum creatinine concentrations in an attempt to determine the accuracy of this method in the non-steady state. In addition E/P and Ke was calculated in hospitalized patients, with AKI, and seen in nephrology consultation by the author. In these patients the accuracy of the method was determined by looking at the following metrics; E/P>1, E/P1 and 0.907 (0.841, 0.973) for 0.95 ml/min accurately predicted the ability to terminate renal replacement therapy in AKI. Include the need to measure urine volume accurately. Furthermore the precision of the method requires accurate estimates of sGFR, while a reasonable measure of P is crucial to estimating Ke. The present study provides the

  18. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies

    OpenAIRE

    Reischies, Frederike M. J.; Raggam, Reinhard B.; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-01-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with...

  19. Risk Stratification of Acute Kidney Injury Using the Blood Urea Nitrogen/Creatinine Ratio in Patients With Acute Decompensated Heart Failure.

    Science.gov (United States)

    Takaya, Yoichi; Yoshihara, Fumiki; Yokoyama, Hiroyuki; Kanzaki, Hideaki; Kitakaze, Masafumi; Goto, Yoichi; Anzai, Toshihisa; Yasuda, Satoshi; Ogawa, Hisao; Kawano, Yuhei

    2015-01-01

    Risk stratification of acute kidney injury (AKI) is important for acute decompensated heart failure (ADHF). The aim of this study was to determine whether clinical markers, such as the blood urea nitrogen/creatinine ratio (BUN/Cr) or BUN or creatinine values alone, stratify the risk of AKI for mortality. In all, 371 consecutive ADHF patients were enrolled in the study. AKI was defined as serum creatinine ≥0.3 mg/dl or a 1.5-fold increase in serum creatinine levels within 48 h. During ADHF therapy, AKI occurred in 99 patients; 55 patients died during the 12-month follow-up period. Grouping patients according to AKI and a median BUN/Cr at admission of 22.1 (non-AKI+low BUN/Cr, non-AKI+high BUN/Cr, AKI+low BUN/Cr, and AKI+high BUN/Cr groups) revealed higher mortality in the AKI+high BUN/Cr group (log-rank test, Phigh BUN/Cr and mortality, whereas the association with AKI+low BUN/Cr did not reach statistical significance. When patients were grouped according to AKI and median BUN or creatinine values at admission, AKI was associated with mortality, regardless of BUN or creatinine. The combination of AKI and elevated BUN/Cr, but not BUN or creatinine individually, is linked with an increased risk of mortality in ADHF patients, suggesting that the BUN/Cr is useful for risk stratification of AKI.

  20. Effect of Oestrogen on Altering the Serum and Urinary Levels of Calcium, Phosphate and Magnesium in Hysterectomised Women Compared to Natural Menopausal South Indian Women: A Case Control Study.

    Science.gov (United States)

    Sonu, Yeldose; Avinash, S S; Sreekantha; Arun Kumar, K; Malathi, M; Shivashankara, A R

    2016-07-01

    Given the paucity of studies conducted to know the effect of suddenness and earlier onset of endocrinological changes associated with hysterectomy, on the serum and urinary levels of calcium, magnesium and phosphate the present study was conducted to compare the levels of calcium, magnesium and phosphate in serum and urine of hysterectomised and natural menopausal south Indian women. This is a cross-sectional observational study. The study included three groups of 30 healthy premenopausal, 30 early surgical menopausal and 30 natural post menopausal women. Women suffering from any endocrine disease were excluded. Analysis was performed in serum and urine sample. The levels of calcium, magnesium and phosphate in serum and calcium/creatinine, magnesium/creatinine and phosphate/creatinine ratio were estimated in urine by spectrophotometric method. Hysterectomised women (serum calcium: 8.7 ± 0.09 mg/dl; urine calcium/creatinine: 0.16 ± 0.02) have significantly low serum calcium (p women (serum magnesium: 2.1 ± 0.03; serum phosphate: 4.4 ± 0.16; urinary calcium/creatinine: 0.17 ± 0.02; urinary magnesium/creatinine: 0.09 ± 0.01) have significantly high serum magnesium (p = 0.016), serum phosphate (p = 0.043) and high urinary calcium/creatinine (p = 0.002), magnesium/creatinine ratio (p = 0.025) compared to healthy pre menopausal women. Post menopausal women (serum calcium: 9.1 ± 0.08) have significantly high serum calcium and phosphate compared to hysterectomised women (serum phosphate: 3.93 ± 0.11). Hysterectomised women have significantly low serum calcium, oestrogen and high urinary calcium/creatinine ratio compared to healthy premenopausal women and low serum calcium and low serum phosphate compared to natural postmenopausal women. Natural postmenopausal women had low serum oestrogen and high serum magnesium, serum phosphate, urinary calcium creatinine ratio and urinary magnesium creatinine ratio compared to healthy premenopausal

  1. Multicenter study of creatinine- and/or cystatin C-based equations for estimation of glomerular filtration rates in Chinese patients with chronic kidney disease.

    Directory of Open Access Journals (Sweden)

    Jia-fu Feng

    Full Text Available OBJECTIVE: To establish equations for the estimation of glomerular filtration rates (eGFRs based on serum creatinine (SCr and/or serum cystatin C (SCysC in Chinese patients with chronic kidney disease (CKD, and to compare the new equations with both the reference GFR (rGFR and the literature equations to evaluate their applicability. METHODS: The 788 Chinese CKD patients were randomly divided into two groups, the training group and the testing group, to establish new eGFR-formulas based on serum CysC and to validate the established formulas, respectively. (99mTc-DTPA clearance (as the rGFR, serum Cr, and serum CysC were determined for all patients, and GFR was calculated using the Cockcroft-Gault equation (eGFR1, the MDRD formula (eGFR2, the CKD-EPI formulas (eGFR3, eGFR4, and the Chinese eGFR Investigation Collaboration formulas (eGFR5, eGFR6. The accuracy of each eGFR was compared with the rGFR. RESULTS: The training and testing groups' mean GFRs were 50.84±31.36 mL/min/1.73 m(2 and 54.16±29.45 mL/min/1.73 m(2, respectively. The two newly developed eGFR formulas were fitted using iterative computation: [Formula: see text] and [Formula: see text]. Significant correlation was observed between each eGFR and the rGFR. However, proportional errors and constant errors were observed between rGFR and eGFR1, eGFR2, eGFR4, eGFR5 or eGFR6, and constant errors were observed between eGFR3 and rGFR, as revealed by the Passing & Bablok plot analysis. The Bland-Altman analysis illustrated that the 95% limits of agreement of all equations exceeded the previously accepted limits of <60 mL/min •1.73 m(2, except the equations of eGFR7 and eGFR8. CONCLUSION: The newly developed formulas, eGFR7 and eGFR8, provide precise and accurate GFR estimation using serum CysC detection alone or in combination with serum Cr detection. Differences in detection methods should be carefully considered when choosing literature eGFR equations to avoid misdiagnosis and

  2. Cloning and Characterization of ThSHRs and ThSCR Transcription Factors in Taxodium Hybrid 'Zhongshanshan 406'.

    Science.gov (United States)

    Wang, Zhiquan; Yin, Yunlong; Hua, Jianfeng; Fan, Wencai; Yu, Chaoguang; Xuan, Lei; Yu, Fangyuan

    2017-07-20

    Among the GRAS family of transcription factors, SHORT ROOT (SHR) and SCARECROW (SCR) are key regulators of the formation of root tissues. In this study, we isolated and characterized two genes encoding SHR proteins and one gene encoding an SCR protein: ThSHR1 (Accession Number MF045148), ThSHR2 (Accession Number MF045149) and ThSCR (Accession Number MF045152) in the adventitious roots of Taxodium hybrid 'Zhongshanshan'. Gene structure analysis indicated that ThSHR1 , ThSHR2 and ThSCR are all intron free. Multiple protein sequence alignments showed that each of the corresponding proteins, ThSHR1, ThSHR2 and ThSCR, contained five well-conserved domains: leucine heptad repeat I (LHRI), the VHIID motif, leucine heptad repeat II (LHR II), the PFYRE motif, and the SAW motif. The phylogenetic analysis indicated that ThSCR was positioned in the SCR clade with the SCR proteins from eight other species, while ThSHR1 and ThSHR2 were positioned in the SHR clade with the SHR proteins from six other species. Temporal expression patterns of these genes were profiled during the process of adventitious root development on stem cuttings. Whereas expression of both ThSHR2 and ThSCR increased up to primary root formation before declining, that of ThSHR1 increased steadily throughout adventitious root formation. Subcellular localization studies in transgenic poplar protoplasts revealed that ThSHR1, ThSHR2 and ThSCR were localized in the nucleus. Collectively, these results suggest that the three genes encode Taxodium GRAS family transcription factors, and the findings contribute to improving our understanding of the expression and function of SHR and SCR during adventitious root production, which may then be manipulated to achieve high rates of asexual propagation of valuable tree species.

  3. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Alloy SCR-3 resistant to stress corrosion cracking

    International Nuclear Information System (INIS)

    Kowaka, Masamichi; Fujikawa, Hisao; Kobayashi, Taiki

    1977-01-01

    Austenitic stainless steel is used widely because the corrosion resistance, workability and weldability are excellent, but the main fault is the occurrence of stress corrosion cracking in the environment containing chlorides. Inconel 600, most resistant to stress corrosion cracking, is not necessarily safe under some severe condition. In the heat-affected zone of SUS 304 tubes for BWRs, the cases of stress corrosion cracking have occurred. The conventional testing method of stress corrosion cracking using boiling magnesium chloride solution has been problematical because it is widely different from actual environment. The effects of alloying elements on stress corrosion cracking are remarkably different according to the environment. These effects were investigated systematically in high temperature, high pressure water, and as the result, Alloy SCR-3 with excellent stress corrosion cracking resistance was found. The physical constants and the mechanical properties of the SCR-3 are shown. The states of stress corrosion cracking in high temperature, high pressure water containing chlorides and pure water, polythionic acid, sodium phosphate solution and caustic soda of the SCR-3, SUS 304, Inconel 600 and Incoloy 800 are compared and reported. (Kako, I.)

  5. Reactivity of Surface Nitrates in H2-Assisted SCR of NOx Over Ag/Al2O3 Catalyst

    DEFF Research Database (Denmark)

    Sadokhina, N. A.; Doronkin, Dmitry E.; Baeva, G. N.

    2013-01-01

    The role of nitrate ad-species in H2-assisted SCR over Ag/Al2O3 was compared in NH3-SCR and n-C6H14-SCR processes. It was found that nitrates could be reduced by NH3 or n-C6H14 at similar rates with H2 co-feeding which indicates a common rate-limiting step. However, contributions of surface nitrate...... reduction to the overall NH3-SCR or n-C6H14-SCR are different as revealed by comparing the rates of nitrate reduction with the rates of steady-state processes. The rate of the steady-state n-C6H14-SCR is virtually identical to the rate of surface nitrate reduction suggesting a significant contribution...... of the surface nitrates reduction to the overall n-C6H14-SCR process. On the other hand, the steady-state rate of NH3-SCR is by ~15 times higher, which indicates that the reduction of surface nitrates plays a marginal role in the overall NH3-SCR....

  6. State Estimation in the Automotive SCR DeNOx Process

    DEFF Research Database (Denmark)

    Zhou, Guofeng; Jørgensen, John Bagterp; Duwig, Christophe

    2012-01-01

    on exhaust gas emissions. For advanced control, e.g. Model Predictive Control (MPC), of the SCR process, accurate state estimates are needed. We investigate the performance of the ordinary and the extended Kalman filters based on a simple first principle system model. The performance is tested through......Selective catalytic reduction (SCR) of nitrogen oxides (NOx) is a widely applied diesel engine exhaust gas after-treatment technology. For effective NOx removal in a transient operating automotive application, controlled dosing of urea can be used to meet the increasingly restrictive legislations...

  7. Serum Uric Acid Levels and Uric Acid/Creatinine Ratios in Stable Chronic Obstructive Pulmonary Disease (COPD) Patients: Are These Parameters Efficient Predictors of Patients at Risk for Exacerbation and/or Severity of Disease?

    Science.gov (United States)

    Durmus Kocak, Nagihan; Sasak, Gulsah; Aka Akturk, Ulku; Akgun, Metin; Boga, Sibel; Sengul, Aysun; Gungor, Sinem; Arinc, Sibel

    2016-11-03

    BACKGROUND Serum uric acid (sUA) levels were previously found to be correlated with hypoxic states. We aimed to determine the levels of sUA and sUA/creatinine ratios in stable COPD patients and to evaluate whether sUA level and sUA/creatinine ratio can be used as predictors of exacerbation risk and disease severity. MATERIAL AND METHODS This cross-sectional study included stable COPD patients and healthy controls. The sUA levels and sUA/creatinine ratios in each group were evaluated and their correlations with the study parameters were investigated. ROC analyses for exacerbation risk and disease severity were reported. RESULTS The study included 110 stable COPD patients and 52 healthy controls. The mean sUA levels and sUA/creatinine ratios were significantly higher in patients with COPD compared to healthy controls. The most common comorbidities in COPD patients were hypertension, diabetes, and coronary artery disease. While sUA levels were significantly higher in patients with hypertension (p=0.002) and malignancy (p=0.033), sUA/creatinine ratios was higher in patients with malignancy (p=0.004). The ROC analyses indicated that sUA/creatinine ratios can be more useful than sUA levels in predicting exacerbation risk (AUC, 0.586 vs. 0.426) and disease severity (AUC, 0.560 vs. 0.475) especially at higher cut-off values, but with low specificity. CONCLUSIONS Our study suggested that sUA levels and sUA/creatinine ratios increased in patients with stable COPD, especially among patients with certain comorbidities compared to healthy controls. At higher cut-off values, sUA levels and especially sUA/creatinine ratios, might be useful in predicting COPD exacerbation risk and disease severity. Also, their association with comorbidities, especially with malignancy and hypertension, may benefit from further investigation.

  8. EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    J. A. Withum; S.C. Tseng; J. E. Locke

    2004-10-31

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on Hg speciation and the efficacy of different FGD technologies for Hg capture. This document, the second in a series of topical reports, describes the results and analysis of mercury sampling performed on a 330 MW unit burning a bituminous coal containing 1.0% sulfur. The unit is equipped with a SCR system for NOx control and a spray dryer absorber for SO{sub 2} control followed by a baghouse unit for particulate emissions control. Four sampling tests were performed in March 2003. Flue gas mercury speciation and concentrations were determined at the SCR inlet, air heater outlet (ESP inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process stream samples for a mercury balance were collected to coincide with the flue gas measurements. Due to mechanical problems with the boiler feed water pumps, the actual gross output was between 195 and 221 MW during the tests. The results showed that the SCR/air heater combination oxidized nearly 95% of the elemental mercury. Mercury removal, on a

  9. Empirical relationships among oliguria, creatinine, mortality, and renal replacement therapy in the critically ill.

    Science.gov (United States)

    Mandelbaum, Tal; Lee, Joon; Scott, Daniel J; Mark, Roger G; Malhotra, Atul; Howell, Michael D; Talmor, Daniel

    2013-03-01

    The observation periods and thresholds of serum creatinine and urine output defined in the Acute Kidney Injury Network (AKIN) criteria were not empirically derived. By continuously varying creatinine/urine output thresholds as well as the observation period, we sought to investigate the empirical relationships among creatinine, oliguria, in-hospital mortality, and receipt of renal replacement therapy (RRT). Using a high-resolution database (Multiparameter Intelligent Monitoring in Intensive Care II), we extracted data from 17,227 critically ill patients with an in-hospital mortality rate of 10.9 %. The 14,526 patients had urine output measurements. Various combinations of creatinine/urine output thresholds and observation periods were investigated by building multivariate logistic regression models for in-hospital mortality and RRT predictions. For creatinine, both absolute and percentage increases were analyzed. To visualize the dependence of adjusted mortality and RRT rate on creatinine, the urine output, and the observation period, we generated contour plots. Mortality risk was high when absolute creatinine increase was high regardless of the observation period, when percentage creatinine increase was high and the observation period was long, and when oliguria was sustained for a long period of time. Similar contour patterns emerged for RRT. The variability in predictive accuracy was small across different combinations of thresholds and observation periods. The contour plots presented in this article complement the AKIN definition. A multi-center study should confirm the universal validity of the results presented in this article.

  10. [Pathophysiological basis of portal hypertension and the new concept of acute kidney injury in patients with liver cirrhosis].

    Science.gov (United States)

    Wang, J B

    2017-06-20

    Recently, the International Club of Ascites (ICA) has developed a new expert consensus on the diagnosis and treatment of acute kidney injury (AKI) in patients with liver cirrhosis, which reflects the new concept of AKI management in patients with liver cirrhosis. This consensus emphasizes the increase in the absolute value of serum creatinine (SCr) and establishes a new staging system for AKI, which may help to evaluate disease progression and recovery. In addition, the new management concept also emphasizes that when AKI progresses to stage 2/3 or still progresses after comprehensive treatment, a diagnosis can be made and vasoconstrictors and albumin can be used as long as the patient meets the other diagnostic criteria for hepatorenal syndrome, regardless of SCr level.

  11. Routine reporting of estimated glomerular filtration rate (eGFR) in African laboratories and the need for its increased utilisation in clinical practice.

    Science.gov (United States)

    Adebisi, Simeon A

    2013-03-01

    Chronic Kidney Disease (CKD) is defined as the presence of markers of kidney damage or of estimated glomerular filtration rate (eGFR)clinical practice. Current guidelines advocate the use of prediction equations, such as the Cockcroft-Gault (CG) formula and the Modification of Diet in Renal Disease (MDRD) study-derived equations. Laboratories in African should commence routine reporting of eGFR for a number of reasons; 1. The sensitivity of serum creatinine (Scr) in identifying CKD is low.2. In Nigeria, a representative country; screening for Chronic Kidney Disease (CKD) is hardly considered in the routine practice of the primary and secondary care medical officers.3 Studies have shown that routine reporting of eGFR improved the documentation and identification of CKD by almost 50%.4 There is the possibility of reversing CKD if picked earlier.5. The high cost of treating CKD patients in advanced stages and the low per capital income status of the populace in Sub-Saharan Africa.6. Poor health infrastructure to manage advanced CKD patients in the continent.7. Several studies, now show lack of awareness of CKD among non-nephrologists that is related, at least in part, to difficulty in interpreting serum creatinine concentrations (the reciprocal, non-linear relationship between GFR and serum creatinine).8 Mathematical estimates of GFR [ as in eGFR] that incorporate creatinine concentration, as well as factors affecting creatinine production rates, such as size, gender, age and ethnic background, are more sensitive to changes in renal function than serum creatinine value alone.9 Recent guidelines define "action plans" for CKD according to the GFR, including referral to nephrologists at GFRs<30 mL.min(-1).(1.73 m2).

  12. Deactivation of SCR catalysts by potassium: A study of potential alkali barrier materials

    DEFF Research Database (Denmark)

    Olsen, Brian Kjærgaard; Kügler, Frauke; Castellino, Francesco

    2017-01-01

    The use of coatings in order to protect vanadia based SCR catalysts against potassium poisoning has been studied by lab- and pilot-scale experiments. Three-layer pellets, consisting of a layer ofa potential coating material situated between layers of fresh and potassium poisoned SCR catalyst, were...... the coating process. Potassium had to some extent penetrated the MgO coat, and SEM analysis revealed it to be rather thick and fragile. Despite these observations, the coating did protect the SCR catalyst against potassium poisoning to some degree, leaving promise of further optimization....... used to test the ability of the barrier layer to block the diffusion of potassium across the pellet. Of MgO, sepiolite and Hollandite manganese oxide, MgO was the most effective potassium barrier, and no potassium was detected in the MgO layer upon exposure to SCR conditions for 7 days. Two monoliths...

  13. A joint model for longitudinal and time-to-event data to better assess the specific role of donor and recipient factors on long-term kidney transplantation outcomes.

    Science.gov (United States)

    Fournier, Marie-Cécile; Foucher, Yohann; Blanche, Paul; Buron, Fanny; Giral, Magali; Dantan, Etienne

    2016-05-01

    In renal transplantation, serum creatinine (SCr) is the main biomarker routinely measured to assess patient's health, with chronic increases being strongly associated with long-term graft failure risk (death with a functioning graft or return to dialysis). Joint modeling may be useful to identify the specific role of risk factors on chronic evolution of kidney transplant recipients: some can be related to the SCr evolution, finally leading to graft failure, whereas others can be associated with graft failure without any modification of SCr. Sample data for 2749 patients transplanted between 2000 and 2013 with a functioning kidney at 1-year post-transplantation were obtained from the DIVAT cohort. A shared random effect joint model for longitudinal SCr values and time to graft failure was performed. We show that graft failure risk depended on both the current value and slope of the SCr. Deceased donor graft patient seemed to have a higher SCr increase, similar to patient with diabetes history, while no significant association of these two features with graft failure risk was found. Patient with a second graft was at higher risk of graft failure, independent of changes in SCr values. Anti-HLA immunization was associated with both processes simultaneously. Joint models for repeated and time-to-event data bring new opportunities to improve the epidemiological knowledge of chronic diseases. For instance in renal transplantation, several features should receive additional attention as we demonstrated their correlation with graft failure risk was independent of the SCr evolution.

  14. Effect of atorvastatin on preventing contrast-induced nephropathy

    Energy Technology Data Exchange (ETDEWEB)

    Dongya, Zhang; Jing, Zhu; Jianchang, Chen; Weiting, Xu; Xiaoyu, Luo; Liangping, Zhao [Dept of Cardiology, the Second Hospital Affiliated to Soochow University, Suzhou (China)

    2011-03-15

    Objective: To study the effects of atorvastatin on contrast-induced renal function and urinary protein change in patients undergoing diagnostic and therapeutic coronary intervention. Methods: Two hundred and forty-six patients who underwent coronary angiography or percutaneous coronary intervention (PCI) were randomized to receive atorvastatin (40 mg, qn, n=123) or no atorvastatin (n=123) treatment 3 days before coronary angiography. All patients received hydrated therapy. Serum creatinine (Scr), urinary {alpha}l-microglobulin ({alpha}{sub l}-MG), and urinary albumin (mALB) were checked for evidence of tubular or glomerular damage at start, and 36 to 48 hours after the administration of a radiocontrast agent. High-sensitive C-reactive protein (hsCRP) levels, urinary {alpha}{sub l}-MG/ urinary creatinine(Ucr) and mALB/ Ucr were also assessed at the same time. Creatinine clearance(Ccr) was calculated according to Cockcroft-Gault formulas basing on serum creatinine. Results: (1) In the control group and atorvastatin-treated group, comparison with the value before coronary angiography or PCI, urinary {alpha}{sub l}-MG/ Ucr, mALB/ Ucr, Scr and hsCRP significantly increased from 36 to 48 hours after angiography or PCI (P<0.05). Ccr significantly decreased from 36 to 48 hours after angiography or PCI (P<0.05). (2) Compared the atorvastatin-treated group, the values of hsCRP, urinary {alpha}{sub l}-MG/ Ucr significantly increased at the 2nd day after angiography or PCI in the control group (P<0.05), incidence of contrast induced nephropathy (CIN) significantly increased too (8.13% vs 0.81%, P<0.05). Conclusions: Contrast media induces light renal function damage. Pretreatment with atorvastatin 40 mg/qn for 3 days could significantly reduce procedural inflammatory reaction and prevent contrast-induced nephropathy. (authors)

  15. Atorvastatin attenuates experimental contrast-induced acute kidney injury: a role for TLR4/MyD88 signaling pathway.

    Science.gov (United States)

    Yue, Rongzheng; Zuo, Chuan; Zeng, Jing; Su, Baihai; Tao, Ye; Huang, Songmin; Zeng, Rui

    2017-11-01

    To investigate the protective effect of different atorvastatin doses on contrast-induced acute kidney injury and the related mechanism. Healthy male Sprague-Dawley (SD) rats were randomly divided into the blank control group, experimental control group and different-dose atorvastatin groups. A rat model of contrast-induced acute kidney injury was established. We detected changes in serum creatinine (Scr) and blood urea nitrogen (BUN) before and after model establishment, observed and scored renal tubular injury, analyzed rat renal cell apoptosis, and measure the expression of signal pathway proteins and downstream inflammatory factors. After contrast agent injection, the Scr and BUN levels of the experimental control group were significantly increased, the different doses applied in the atorvastatin group significantly reduced the Scr and BUN levels (p atorvastatin doses have protective effects on contrast-induced acute renal tubular injury in rats, possibly by targeting TLR4, suppressing TLR4 expression, regulating the TLR4/Myd88 signaling pathway, and inhibiting the expression of downstream inflammatory factors.

  16. Utility of intravenous nonionic contrast media for abdominal CT in patients with renal dysfunction

    International Nuclear Information System (INIS)

    Craig, B.M.; Alpern, M.B.; Sandler, M.A.; Pearlberg, J.L.; Swanson, D.P.

    1987-01-01

    The safety and efficacy of a nonionic contrast medium (NICM) for CT enhancements in patients with renal dysfunction were evaluated. Thirty consecutive patients referred for abdominal CT with a serum creatinine (SCr) level over 5 mg/dL or a SCr level of 2-5 mg/dL and another risk factor (e.g., diabetes, single kidney) received NICM. Each was matched with a control who received the same 150-mL bolus of a conventional medium. No adverse reactions or significant alterations in SCr values were found in the NICM patients. No significant differences between the patient groups were found in blinded subjective image quality ratings or measured attenuation values of a parenchymal organs and vascular structures (with the exception of less renal enhancement in the NICM patients, reflecting their renal dysfunction). Use of an NICM is a safe and effective method for contrast medium-enhanced CT in patients with renal dysfunction

  17. Determination of the best method to estimate glomerular filtration rate from serum creatinine in adult patients with sickle cell disease: a prospective observational cohort study

    Directory of Open Access Journals (Sweden)

    Arlet Jean-Benoît

    2012-08-01

    Full Text Available Abstract Background Sickle cell disease (SCD leads to tissue hypoxia resulting in chronic organ dysfunction including SCD associated nephropathy. The goal of our study was to determine the best equation to estimate glomerular filtration rate (GFR in SCD adult patients. Methods We conducted a prospective observational cohort study. Since 2007, all adult SCD patients in steady state, followed in two medical departments, have had their GFR measured using iohexol plasma clearance (gold standard. The Cockcroft-Gault, MDRD-v4, CKP-EPI and finally, MDRD and CKD-EPI equations without adjustment for ethnicity were tested to estimate GFR from serum creatinine. Estimated GFRs were compared to measured GFRs according to the graphical Bland and Altman method. Results Sixty-four SCD patients (16 men, median age 27.5 years [range 18.0-67.5], 41 with SS-genotype were studied. They were Sub-Saharan Africa and French West Indies natives and predominantly lean (median body mass index: 22 kg/m2 [16-33]. Hyperfiltration (defined as measured GFR >110 mL/min/1.73 m2 was detected in 53.1% of patients. Urinary albumin/creatinine ratio was higher in patients with hyperfiltration than in patients with normal GFR (4.05 mg/mmol [0.14-60] versus 0.4 mg/mmol [0.7-81], p = 0.01. The CKD-EPI equation without adjustment for ethnicity had both the lowest bias and the greatest precision. Differences between estimated GFRs using the CKP-EPI equation and measured GFRs decreased with increasing GFR values, whereas it increased with the Cockcroft-Gault and MDRD-v4 equations. Conclusions We confirm that SCD patients have a high rate of glomerular hyperfiltration, which is frequently associated with microalbuminuria or macroalbuminuria. In non-Afro-American SCD patients, the best method for estimating GFR from serum creatinine is the CKD-EPI equation without adjustment for ethnicity. This equation is particularly accurate to estimate high GFR values, including glomerular

  18. Two low-cost digital camera-based platforms for quantitative creatinine analysis in urine.

    Science.gov (United States)

    Debus, Bruno; Kirsanov, Dmitry; Yaroshenko, Irina; Sidorova, Alla; Piven, Alena; Legin, Andrey

    2015-10-01

    In clinical analysis creatinine is a routine biomarker for the assessment of renal and muscular dysfunctions. Although several techniques have been proposed for a fast and accurate quantification of creatinine in human serum or urine, most of them require expensive or complex apparatus, advanced sample preparation or skilled operators. To circumvent these issues, we propose two home-made platforms based on a CD Spectroscope (CDS) and Computer Screen Photo-assisted Technique (CSPT) for the rapid assessment of creatinine level in human urine. Both systems display a linear range (r(2) = 0.9967 and 0.9972, respectively) from 160 μmol L(-1) to 1.6 mmol L(-1) for standard creatinine solutions (n = 15) with respective detection limits of 89 μmol L(-1) and 111 μmol L(-1). Good repeatability was observed for intra-day (1.7-2.9%) and inter-day (3.6-6.5%) measurements evaluated on three consecutive days. The performance of CDS and CSPT was also validated in real human urine samples (n = 26) using capillary electrophoresis data as reference. Corresponding Partial Least-Squares (PLS) regression models provided for mean relative errors below 10% in creatinine quantification. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. The development and application of SCR denitrification technology in power plant

    Science.gov (United States)

    Wu, Junnan

    2017-12-01

    In recent decades, the emission of the nitrogen oxides (NOX) has been increasing with the years of the thermal power plant. The environment pollution caused by the emission of quantities of nitrogen oxides became more and more serious, so people now put more emphasis on the control of the emission of the nitrogen oxides. Especially, our country and the society are paying much more attention to the environment protection and the environment problems cannot be neglected. In this paper, we introduced the related research background of the technology of SCR denitrification which was as the symbol of the technology of the catalytic denitrification and discussed the reaction principles of the SCR denitrification and frequently used catalysts, the process of the technology, and the configuration. In the end, we pointed the way of the future research of the technology of the SCR denitrification.

  20. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    Science.gov (United States)

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  1. Correlation of Serum Cystatin C with Glomerular Filtration Rate in Patients Receiving Platinum-Based Chemotherapy

    Directory of Open Access Journals (Sweden)

    Ernesta Cavalcanti

    2016-01-01

    Full Text Available Objectives. Serum cystatin C seems to be an accurate marker of glomerular filtration rate (GFR compared to serum creatinine. The aim of this work was to explore the possibility of using serum cystatin C instead of serum creatinine to early predict renal failure in cancer patients who received platinum based chemotherapy. Design and Methods. Serum creatinine, serum cystatin C concentrations, and GFR were determined simultaneously in 52 cancer patients received carboplatin-based or cisplatin-based chemotherapy. Serum creatinine was assayed on Cobas C6000-Roche, serum cystatin C assay was performed on AIA 360-Tosoh, and GFR was determined in all patients, before the first cycle of chemotherapy and before the subsequent administrations. Results. In the overall series, for the prediction of a fall of GFR < 80 mL/min/1.73 m2, the AUC of the ROC curve for cystatin C was 0,667 and the best threshold was 1.135 mg/L (sensitivity 90.5%, specificity 61.1%. For a GFR fall < 60 mL/min/1.73 m2, the AUC of ROC curve for cystatin C was 74.3% and the best threshold was 1.415 mg/L (sensitivity 66.7%, specificity 73.2%. Conclusions. Baseline cystatin C values were not able to predict renal failure during subsequent treatment. In conclusion, serum cystatin C is not a reliable early marker to efficiently predict renal failure in patients receiving chemotherapy.

  2. Fe-BEA Zeolite Catalysts for NH3-SCR of NOx

    DEFF Research Database (Denmark)

    Frey, Anne Mette; Mert, Selcuk; Due-Hansen, Johannes

    2009-01-01

    Iron-containing zeolites are known to be promising catalysts for the NH3-SCR reaction. Here, we will investigate the catalytic activity of iron-based BEA catalysts, which was found to exhibit improved activities compared to previously described iron-containing zeolite catalysts, such as ZSM-5...... and ZSM-12. Series of Fe-BEA zeolite catalysts were prepared using a range of different preparation methods. Furthermore, we found that an iron concentration around 3 wt% on BEA showed a small optimum in SCR activity compared to the other iron loadings studied....

  3. COST OF SELECTIVE CATALYTIC REDUCTION (SCR) APPLICATION FOR NOX CONTROL ON COAL-FIRED BOILERS

    Science.gov (United States)

    The report provides a methodology for estimating budgetary costs associated with retrofit applications of selective catalytic reduction (SCR) technology on coal-fired boilers. SCR is a postcombustion nitrogen oxides (NOx) control technology capable of providing NOx reductions >90...

  4. Regenerative Snubber For GTO-Commutated SCR Inverter

    Science.gov (United States)

    Rippel, Wally E.; Edwards, Dean B.

    1992-01-01

    Proposed regenerative snubbing circuit substituted for dissipative snubbing circuit in inverter based on silicon controlled rectifiers (SCR's) commutated by gate-turn-off thyristor (GTO). Intended to reduce loss of power that occurs in dissipative snubber. Principal criteria in design: low cost, simplicity, and reliability.

  5. Operational Choices for Risk Aggregation in Insurance: PSDization and SCR Sensitivity

    Directory of Open Access Journals (Sweden)

    Xavier Milhaud

    2018-04-01

    Full Text Available This work addresses crucial questions about the robustness of the PSDization process for applications in insurance. PSDization refers to the process that forces a matrix to become positive semidefinite. For companies using copulas to aggregate risks in their internal model, PSDization occurs when working with correlation matrices to compute the Solvency Capital Requirement (SCR. We examine how classical operational choices concerning the modelling of risk dependence impacts the SCR during PSDization. These operations refer to the permutations of risks (or business lines in the correlation matrix, the addition of a new risk, and the introduction of confidence weights given to the correlation coefficients. The use of genetic algorithms shows that theoretically neutral transformations of the correlation matrix can surprisingly lead to significant sensitivities of the SCR (up to 6%. This highlights the need for a very strong internal control around the PSDization step.

  6. Characteristics of Sucrose Transport through the Sucrose-Specific Porin ScrY Studied by Molecular Dynamics Simulations

    Directory of Open Access Journals (Sweden)

    Liping eSun

    2016-02-01

    Full Text Available Sucrose-specific porin (ScrY is a transmembrane protein that allows for the uptake of sucrose under growth-limiting conditions. The crystal structure of ScrY was resolved before by X-ray crystallography, both in its uncomplexed form and with bound sucrose. However, little is known about the molecular characteristics of the transport mechanism of ScrY. To date, there has not yet been any clear demonstration for sucrose transport through the ScrY.Here, the dynamics of the ScrY trimer embedded in a phospholipid bilayer as well as the characteristics of sucrose translocation were investigated by means of atomistic molecular dynamics (MD simulations. The potential of mean force (PMF for sucrose translocation through the pore showed two main energy barriers within the constriction region of ScrY. Energy decomposition allowed to pinpoint three aspartic acids as key residues opposing the passage of sucrose, all located within the L3 loop. Mutation of two aspartic acids to uncharged residues resulted in an accordingly modified electrostatics and decreased PMF barrier. The chosen methodology and results will aid in the design of porins with modified transport specificities.

  7. Glutamyl aminopeptidase in microvesicular and exosomal fractions of urine is related with renal dysfunction in cisplatin-treated rats.

    Directory of Open Access Journals (Sweden)

    Andrés Quesada

    Full Text Available The aim of this work was to investigate if the content of glutamyl aminopeptidase (GluAp in microvesicular and exosomal fractions of urine is related with renal dysfunction in cisplatin-treated rats.Urine samples were collected 24 hours after injection of cisplatin (7 mg/kg, n = 10 or saline serum (n = 10, and they were subjected to differential centrifugation at 1.000, 17.000 and 200.000 g to obtain microvesicular and exosomal fractions. GluAp was measured with a commercial ELISA kit in both fractions. Serum creatinine (SCr and body weight were measured 15 days after treatment. We analyzed if early excretion of GluAp in microsomal and exosomal fractions was correlated with final SCr and body weight increase. In a second experiment, enzymatic activities of GluAp and alanyl aminopeptidase (AlaAp in urine, microvesicular and exosomal fractions were measured three days after injection. We analyzed the correlation of both markers with SCr determined at this point. Finally, we studied the expression of GluAp and extracellular vesicles markers Alix and tumor susceptibility gene (TSG101 in both fractions by immunoblotting.GluAp excretion was increased in all fractions of urine after cisplatin treatment, even if data were normalized per mg of creatinine, per body weight or per total protein content of each fraction. We found significant predictive correlations with SCr concentration, and inverse correlations with body weight increase determined 15 days later. Three days after injection, aminopeptidasic activities were markedly increased in all fractions of urine in cisplatin-treated rats. The highest correlation coefficient with SCr was found for GluAp in microvesicular fraction. Increase of GluAp in microvesicular and exosomal fractions from cisplatin-treated rats was confirmed by immunoblotting. Alix and TSG101 showed different patterns of expression in each fraction.Determination of GluAp content or its enzymatic activity in microvesicular and

  8. Combining creatinine and volume kinetics identifies missed cases of acute kidney injury following cardiac arrest

    Science.gov (United States)

    2013-01-01

    Introduction Fluid resuscitation in the critically ill often results in a positive fluid balance, potentially diluting the serum creatinine concentration and delaying diagnosis of acute kidney injury (AKI). Methods Dilution during AKI was quantified by combining creatinine and volume kinetics to account for fluid type, and rates of fluid infusion and urine output. The model was refined using simulated patients receiving crystalloids or colloids under four glomerular filtration rate (GFR) change scenarios and then applied to a cohort of critically ill patients following cardiac arrest. Results The creatinine concentration decreased during six hours of fluid infusion at 1 litre-per-hour in simulated patients, irrespective of fluid type or extent of change in GFR (from 0% to 67% reduction). This delayed diagnosis of AKI by 2 to 9 hours. Crystalloids reduced creatinine concentration by 11 to 19% whereas colloids reduced concentration by 36 to 43%. The greatest reduction was at the end of the infusion period. Fluid dilution alone could not explain the rapid reduction of plasma creatinine concentration observed in 39 of 49 patients after cardiac arrest. Additional loss of creatinine production could account for those changes. AKI was suggested in six patients demonstrating little change in creatinine, since a 52 ± 13% reduction in GFR was required after accounting for fluid dilution and reduced creatinine production. Increased injury biomarkers within a few hours of cardiac arrest, including urinary cystatin C and plasma and urinary Neutrophil-Gelatinase-Associated-Lipocalin (biomarker-positive, creatinine-negative patients) also indicated AKI in these patients. Conclusions Creatinine and volume kinetics combined to quantify GFR loss, even in the absence of an increase in creatinine. The model improved disease severity estimation, and demonstrated that diagnostic delays due to dilution are minimally affected by fluid type. Creatinine sampling should be delayed at least

  9. A new approach to define acute kidney injury in term newborns with hypoxic ischemic encephalopathy.

    Science.gov (United States)

    Gupta, Charu; Massaro, An N; Ray, Patricio E

    2016-07-01

    Current definitions of acute kidney injury (AKI) are not sufficiently sensitive to identify all newborns with AKI during the first week of life. To determine whether the rate of decline of serum creatinine (SCr) during the first week of life can be used to identify newborns with AKI, we reviewed the medical records of 106 term neonates at risk of AKI who were treated with hypothermia for hypoxic ischemic encephalopathy (HIE). Of the newborns enrolled in the study, 69 % showed a normal rate of decline of SCr to ≥50 % and/or reached SCr levels of ≤0.6 mg/dl before the 7th day of life, and therefore had an excellent clinical outcome (control group). Thirteen newborns with HIE (12 %) developed AKI according to an established neonatal definition (AKI-KIDGO group), and an additional 20 newborns (19 %) showed a rate of decline of SCr of newborns in the other two groups required more days of mechanical ventilation and vasopressor drugs and had higher gentamicin levels, more fluid overload, lower urinary epidermal growth factor levels, and a prolonged length of stay. The rate of decline of SCr provides a sensitive approach to identify term newborns with AKI during the first week of life.

  10. Population-based estimation of renal function in healthy young Indian adults based on body mass index and sex correlating renal volume, serum creatinine, and cystatin C

    Directory of Open Access Journals (Sweden)

    Rajagopalan P

    2016-09-01

    Full Text Available Prashanth Rajagopalan,1 Georgi Abraham,2 Yuvaram NV Reddy,2 Ravivarman Lakshmanasami,1 ML Prakash,1 Yogesh NV Reddy2 1Department of General Medicine, Mahatma Gandhi Medical College and Research Institute, Puducherry, 2Department of Nephrology, Madras Medical Mission Hospital, Chennai, India Abstract: This population-based prospective study was undertaken in Mahatma Gandhi Medical College to estimate the renal function in young healthy Indian adults. A young healthy heterogeneous Indian cohort comprising 978 individuals, predominantly medical students, was assessed by a detailed questionnaire, and variables such as height, weight, body mass index (BMI, birth weight, and blood pressure were documented. Laboratory investigations included serum creatinine, serum cystatin C, blood sugar, urine protein, and imaging of the kidneys with ultrasound. The mean age of the cohort was 25±6 years, comprising 672 males and 306 females. The estimated glomerular filtration rates (eGFRs by the Cockcroft–Gault formula for BMI <18.5 kg/m2, 18.5–24.99 kg/m2, 25–29.99 kg/m2, and ≥30 kg/m2 were 71.29±10.45 mL/min, 86.38±13.46 mL/min, 98.88±15.29 mL/min, and 109.13±21.57 mL/min, respectively; the eGFRs using cystatin C for the four groups of BMI were 84.53±18.14 mL/min, 84.01±40.11 mL/min, 79.18±13.46 mL/min, and 77.30±10.90 mL/min, respectively. This study attempts to establish a normal range of serum creatinine and cystatin C values for the Indian population and shows that in young healthy Indian adults, eGFR and kidney volume vary by BMI and sex. Keywords: eGFR, birth weight, renal volume

  11. Serum Chemerin Levels Are Associated with Abdominal Visceral Fat in Type 2 Diabetes.

    Science.gov (United States)

    Han, Juyoung; Kim, So Hun; Suh, Young Ju; Lim, Hyun Ae; Shin, Heekyoung; Cho, Soon Gu; Kim, Chei Won; Lee, Seung Youn; Lee, Dae Hyung; Hong, Seongbin; Kim, Yong Seong; Nam, Moon-Suk

    2016-06-01

    Chemerin is a recently identified adipokine suggested to play a role in obesity and its metabolic complications. The relationship between visceral obesity and serum chemerin levels in type 2 diabetes (T2DM) is unknown and may differ from that of subjects without diabetes. Therefore, we evaluated whether serum chemerin was associated with visceral abdominal obesity in patients with T2DM. A total of 218 Korean patients with T2DM were enrolled and metabolic parameters, abdominal visceral and subcutaneous fat areas, and serum chemerin levels were measured. Serum chemerin level showed positive correlation with fasting insulin, HOMA-IR, serum triglyceride, serum creatinine, urine albumin/creatinine ratio, high-sensitivity C-reactive protein (hsCRP), fibrinogen, abdominal visceral fat area, visceral to subcutaneous fat area ratio, and negatively correlation with high density lipoprotein cholesterol and creatinine clearance (CCr) after adjusting for age, gender and body mass index. Multiple linear stepwise regression analysis showed that abdominal visceral fat area (β = 0.001, P abdominal visceral fat area, serum triglyceride, hsCRP and fibrinogen and lower level of CCr in patients with T2DM. Serum chemerin may be used as a biomarker of visceral adiposity and chemerin may play a role in inflammation, decreased renal function, and increased cardiovascular risk in T2DM.

  12. Estimated Glomerular Filtration Rate Correlates Poorly with Four-Hour Creatinine Clearance in Critically Ill Patients with Acute Kidney Injury

    Directory of Open Access Journals (Sweden)

    Christopher J. Kirwan

    2013-01-01

    Full Text Available Introduction. RIFLE and AKIN provide a standardised classification of acute kidney injury (AKI, but their categorical rather than continuous nature restricts their use to a research tool. A more accurate real-time description of renal function in AKI is needed, and some published data suggest that equations based on serum creatinine that estimate glomerular filtration rate (eGFR can provide this. In addition, incorporating serum cystatin C concentration into estimates of GFR may improve their accuracy, but no eGFR equations are validated in critically ill patients with AKI. Aim. This study tests whether creatinine or cystatin-C-based eGFR equations, used in patients with CKD, offer an accurate representation of 4-hour creatinine clearance (4CrCl in critically ill patients with AKI. Methods. Fifty-one critically ill patients with AKI were recruited. Thirty-seven met inclusion criteria, and the performance of eGFR equations was compared to 4CrCl. Results. eGFR equations were better than creatinine alone at predicting 4CrCl. Adding cystatin C to estimates did not improve the bias or add accuracy. The MDRD 7 eGFR had the best combination of correlation, bias, percentage error and accuracy. None were near acceptable standards quoted in patients with chronic kidney disease (CKD. Conclusions. eGFR equations are not sufficiently accurate for use in critically ill patients with AKI. Incorporating serum cystatin C does not improve estimates. eGFR should not be used to describe renal function in patients with AKI. Standards of accuracy for validating eGFR need to be set.

  13. Effect of socio-demographic factors on endogenous biomarkers (cystatin C and creatinine) among elderly chronic kidney disease patients: a cross-sectional study.

    Science.gov (United States)

    Khan, Irfanullah; Khan, Amer Hayat; Adnan, Azreen Syazril; Sulaiman, Syed Azhar Syed; Hamzah, Azhar Bin Amir; Ahmed, Nafees; Khan, Amjad

    2018-06-01

    Creatinine is normally used to evaluate kidney function among elderly patients in clinical practice, which has been reported to be affected by socio-demographic factors like BMI and age. Cystatin C a newly introduced biomarker may be more efficient in identifying kidney function in obese and aged CKD patients. The aim of the current study was to assess the effect of BMI on endogenous biomarkers (cystatin C and creatinine) among elderly CKD patients in Malaysia, a first such study in the country. The current study was conducted at the Hospital University Sains Malaysia, Kelantan. A total of 300 elderly Malay participants ≥ 65 years, with CKD, were taken in study. Demographic data, blood pressure, weight, and height were documented. Serum creatinine was assayed by Chemistry Analyzer Model Architect-C8000 (Jaffe Method), while serum cystatin C was examined by Human cystatin C ELISA kit (Sigma-Aldrich) using Thermo Scientific Varioskan Flash ELISA reader. The study participants were divided into three groups on the basis of age. There was a statistically significant difference at the p value C levels were observed on the basis of patient's age and BMI. Cystatin C is not related to BMI and age among elderly chronic kidney disease patients. The study clearly evaluates the role of serum cystatin C as a good competitor of creatinine among the elderly CKD patients.

  14. Post-standardization of routine creatinine assays: are they suitable for clinical applications.

    Science.gov (United States)

    Jassam, Nuthar; Weykamp, Cas; Thomas, Annette; Secchiero, Sandra; Sciacovelli, Laura; Plebani, Mario; Thelen, Marc; Cobbaert, Christa; Perich, Carmen; Ricós, Carmen; Paula, Faria A; Barth, Julian H

    2017-05-01

    Introduction Reliable serum creatinine measurements are of vital importance for the correct classification of chronic kidney disease and early identification of kidney injury. The National Kidney Disease Education Programme working group and other groups have defined clinically acceptable analytical limits for creatinine methods. The aim of this study was to re-evaluate the performance of routine creatinine methods in the light of these defined limits so as to assess their suitability for clinical practice. Method In collaboration with the Dutch External Quality Assurance scheme, six frozen commutable samples, with a creatinine concentration ranging from 80 to 239  μmol/L and traceable to isotope dilution mass spectrometry, were circulated to 91 laboratories in four European countries for creatinine measurement and estimated glomerular filtration rate calculation. Two out of the six samples were spiked with glucose to give high and low final concentrations of glucose. Results Results from 89 laboratories were analysed for bias, imprecision (%CV) for each creatinine assay and total error for estimated glomerular filtration rate. The participating laboratories used analytical instruments from four manufacturers; Abbott, Beckman, Roche and Siemens. All enzymatic methods in this study complied with the National Kidney Disease Education Programme working group recommended limits of bias of 5% above a creatinine concentration of 100  μmol/L. They also did not show any evidence of interference from glucose. In addition, they also showed compliance with the clinically recommended %CV of ≤4% across the analytical range. In contrast, the Jaffe methods showed variable performance with regard to the interference of glucose and unsatisfactory bias and precision. Conclusion Jaffe-based creatinine methods still exhibit considerable analytical variability in terms of bias, imprecision and lack of specificity, and this variability brings into question their clinical utility

  15. Mercury Oxidation over Selective Catalytic Reduction (SCR) Catalysts - Ph.d. thesis Karin Madsen

    DEFF Research Database (Denmark)

    Madsen, Karin

    The vanadium-based SCR catalyst used for NOx-control promotes the oxidation of elemental mercury Hg0 to Hg2+ in flue gases from coal-fired power plants. Hg2+ is water soluble and can effectively be captured in a wet scrubber. This means that the combination of an SCR with a wet FGD can offer an e...

  16. Deactivation of SCR Catalysts by Additives

    DEFF Research Database (Denmark)

    Castellino, Francesco

    2008-01-01

    forskellige opløsninger af K3PO4. Resultaterne viste, at hvis K bindes i K-P saltforbindelser ville dette ikke reducere hastigheden af katalysatorens deaktivering. Regenereringstest udført i laboratoriet på katalysatorplader viste, at regenerering af de eksponerede katalysatorer var muligt ved at vaske demmed...... 0.5Mvandig opløsning af H2SO4. Somdet sidste blev en kommerciel V2O5-WO3-TiO2 SCR monolit eksponer et i 1000 timer for røggas tilsat en vandig opløsning af KCl, Ca(OH)2, H3PO4 og H2SO4 i en pilotopstilling. Blandingens sammensætning blev justeret med henblik på at have et P/K og P/Ca forhold på...... for KCl eller K3PO4. Dette faktum indikerer at kemisk binding af K i P-K-Ca-forbindelser er en effektiv måde at reducere den negative indflydelse på levetiden af vanadium baserede SCR katalysatorer hidrørende fra alkalimetaller. På den anden side blev fosforafsætning og -belægningsdannelse favoriseret ved...

  17. Stamping SERS for creatinine sensing

    Science.gov (United States)

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan

    2015-03-01

    Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.

  18. Creatinine and urea biosensors based on a novel ammonium ion-selective copper-polyaniline nano-composite.

    Science.gov (United States)

    Zhybak, M; Beni, V; Vagin, M Y; Dempsey, E; Turner, A P F; Korpan, Y

    2016-03-15

    The use of a novel ammonium ion-specific copper-polyaniline nano-composite as transducer for hydrolase-based biosensors is proposed. In this work, a combination of creatinine deaminase and urease has been chosen as a model system to demonstrate the construction of urea and creatinine biosensors to illustrate the principle. Immobilisation of enzymes was shown to be a crucial step in the development of the biosensors; the use of glycerol and lactitol as stabilisers resulted in a significant improvement, especially in the case of the creatinine, of the operational stability of the biosensors (from few hours to at least 3 days). The developed biosensors exhibited high selectivity towards creatinine and urea. The sensitivity was found to be 85 ± 3.4 mAM(-1)cm(-2) for the creatinine biosensor and 112 ± 3.36 mAM(-1)cm(-2) for the urea biosensor, with apparent Michaelis-Menten constants (KM,app), obtained from the creatinine and urea calibration curves, of 0.163 mM for creatinine deaminase and 0.139 mM for urease, respectively. The biosensors responded linearly over the concentration range 1-125 µM, with a limit of detection of 0.5 µM and a response time of 15s. The performance of the biosensors in a real sample matrix, serum, was evaluated and a good correlation with standard spectrophotometric clinical laboratory techniques was found. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  20. Hypotension, bedridden, leukocytosis, thrombocytopenia and elevated serum creatinine predict mortality in geriatric patients with fever.

    Science.gov (United States)

    Chung, Min-Hsien; Chu, Feng-Yuan; Yang, Tzu-Meng; Lin, Hung-Jung; Chen, Jiann-Hwa; Guo, How-Ran; Vong, Si-Chon; Su, Shih-Bin; Huang, Chien-Cheng; Hsu, Chien-Chin

    2015-07-01

    The geriatric population (aged ≥65 years) accounts for 12-24% of all emergency department (ED) visits. Of them, 10% have a fever, 70-90% will be admitted and 7-10% of will die within a month. Therefore, mortality prediction and appropriate disposition after ED treatment are of great concern for geriatric patients with fever. We tried to identify independent mortality predictors of geriatric patients with fever, and combine these predictors to predict their mortality. We enrolled consecutive geriatric patients visiting the ED between 1 June and 21 July 2010 with the following criteria of fever: a tympanic temperature ≥37.2°C or a baseline temperature elevated ≥1.3°C. We used 30-day mortality as the primary end-point. A total of 330 patients were enrolled. Hypotension, bedridden, leukocytosis, thrombocytopenia and serum creatinine >2 mg/dL, but not age, were independently associated with 30-day mortality. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) ranged from 18.2% to 90.9%, 34.7% to 100%, 9.0% to 100% and 94.5% to 98.2%, respectively, depending on how many predictors there were. The 30-day mortality increased with the number of independent mortality predictors. With at least four predictors, 100% of the patients died within 30 days. With none of the predictors, just 1.8% died. These findings might help physicians make decisions about geriatric patients with fever. © 2014 Japan Geriatrics Society.

  1. Digoxin serum levels with respect to some biochemical and clinical indicators

    Energy Technology Data Exchange (ETDEWEB)

    Sedlak, J; Curilla, E [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1984-10-01

    Digoxin serum levels were examined in 40 patients using enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) and correlated with levels of potassium, magnesium, creatinine, urea, glomerular filtration (GF) and with clinical signs of different degrees of digitalis serum concentration. The digoxin level assessed by ELISA and RIA methods correlated fairly closely. An average dependence was found between digoxin levels and levels of creatinine, urea and GF. A correlation was observed between a high level of digoxin and clinical signs of digitalis intoxication.

  2. Digoxin serum levels with respect to some biochemical and clinical indicators

    International Nuclear Information System (INIS)

    Sedlak, J.; Curilla, E.

    1984-01-01

    Digoxin serum levels were examined in 40 patients using enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) and correlated with levels of potassium, magnesium, creatinine, urea, glomerular filtration (GF) and with clinical signs of different degrees of digitalis serum concentration. The digoxin level assessed by ELISA and RIA methods correlated fairly closely. An average dependence was found between digoxin levels and levels of creatinine, urea and GF. A correlation was observed between a high level of digoxin and clinical signs of digitalis intoxication

  3. Existing creatinine-based equations overestimate glomerular filtration rate in Indians.

    Science.gov (United States)

    Kumar, Vivek; Yadav, Ashok Kumar; Yasuda, Yoshinari; Horio, Masaru; Kumar, Vinod; Sahni, Nancy; Gupta, Krishan L; Matsuo, Seiichi; Kohli, Harbir Singh; Jha, Vivekanand

    2018-02-01

    Accurate estimation of glomerular filtration rate (GFR) is important for diagnosis and risk stratification in chronic kidney disease and for selection of living donors. Ethnic differences have required correction factors in the originally developed creatinine-based GFR estimation equations for populations around the world. Existing equations have not been validated in the vegetarian Indian population. We examined the performance of creatinine and cystatin-based GFR estimating equations in Indians. GFR was measured by urinary clearance of inulin. Serum creatinine was measured using IDMS-traceable Jaffe's and enzymatic assays, and cystatin C by colloidal gold immunoassay. Dietary protein intake was calculated by measuring urinary nitrogen appearance. Bias, precision and accuracy were calculated for the eGFR equations. A total of 130 participants (63 healthy kidney donors and 67 with CKD) were studied. About 50% were vegetarians, and the remainder ate meat 3.8 times every month. The average creatinine excretion were 14.7 mg/kg/day (95% CI: 13.5 to 15.9 mg/kg/day) and 12.4 mg/kg/day (95% CI: 11.2 to 13.6 mg/kg/day) in males and females, respectively. The average daily protein intake was 46.1 g/day (95% CI: 43.2 to 48.8 g/day). The mean mGFR in the study population was 51.66 ± 31.68 ml/min/1.73m 2 . All creatinine-based eGFR equations overestimated GFR (p < 0.01 for each creatinine based eGFR equation). However, eGFR by CKD-EPI Cys was not significantly different from mGFR (p = 0.38). The CKD-EPI Cys exhibited lowest bias [mean bias: -3.53 ± 14.70 ml/min/1.73m 2 (95% CI: -0.608 to -0.98)] and highest accuracy (P 30 : 74.6%). The GFR in the healthy population was 79.44 ± 20.19 (range: 41.90-134.50) ml/min/1.73m 2 . Existing creatinine-based GFR estimating equations overestimate GFR in Indians. An appropriately powered study is needed to develop either a correction factor or a new equation for accurate assessment of kidney function in the

  4. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    Science.gov (United States)

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  5. Low NOx combustion and SCR flow field optimization in a low volatile coal fired boiler.

    Science.gov (United States)

    Liu, Xing; Tan, Houzhang; Wang, Yibin; Yang, Fuxin; Mikulčić, Hrvoje; Vujanović, Milan; Duić, Neven

    2018-08-15

    Low NO x burner redesign and deep air staging have been carried out to optimize the poor ignition and reduce the NO x emissions in a low volatile coal fired 330 MW e boiler. Residual swirling flow in the tangentially-fired furnace caused flue gas velocity deviations at furnace exit, leading to flow field unevenness in the SCR (selective catalytic reduction) system and poor denitrification efficiency. Numerical simulations on the velocity field in the SCR system were carried out to determine the optimal flow deflector arrangement to improve flow field uniformity of SCR system. Full-scale experiment was performed to investigate the effect of low NO x combustion and SCR flow field optimization. Compared with the results before the optimization, the NO x emissions at furnace exit decreased from 550 to 650 mg/Nm³ to 330-430 mg/Nm³. The sample standard deviation of the NO x emissions at the outlet section of SCR decreased from 34.8 mg/Nm³ to 7.8 mg/Nm³. The consumption of liquid ammonia reduced from 150 to 200 kg/h to 100-150 kg/h after optimization. Copyright © 2018. Published by Elsevier Ltd.

  6. Study for a stress joint at the top of a SCR (Steel Catenary Risers); Estudo de 'stress joints' para o topo de um SCR (Steel Catenary Risers)

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Elizabeth Frauches Netto; Andrade, Edmundo Queiroz de [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    Steel Catenary Risers, SCRs, need a top connection that bears the force transmitted to the platform. Essentially, two types of connections exist on the market: flex joint and stress joint (SJ). PETROBRAS has a SCR with top connection of flex joint type installed on one of its platforms; however, the company has been studying SJ as an option out of SCR top connection. A stress joint is a monolithic structure and can be inspected during manufacture and service, without so many difficult. They are metal structures composed of a uniform bore inserted in a tapered wall that increases gradually to support the force coming from the riser. The objective of this paper is to present a SJ sensitivity study for a production SCR supposedly hardwired to a unit of production of the semi-submersible type. The data used is based on real SCR data. For this study, global and local analyses were conducted for some models of stress joints, varying some parameters such as material and dimensions, allowing for the verification of some of the critical points of this type of connection. The results obtained will be shown in graphs and tensions maps to illustrate comparatively the critical points of the models analyzed. (author)

  7. Early rise in postoperative creatinine for identification of acute kidney injury after cardiac surgery.

    Science.gov (United States)

    Karkouti, Keyvan; Rao, Vivek; Chan, Christopher T; Wijeysundera, Duminda N

    2017-08-01

    Acute kidney injury (AKI) is a potentially serious complication of cardiac surgery. Treatment strategies are unlikely to prove efficacious unless patients are identified and treated soon after the onset of injury. In this observational study, we determined and validated the ability of an early rise in postoperative serum creatinine to identify patients who suffer AKI during cardiac surgery. The relationship between an early rise in creatinine (immediate postoperative / preoperative creatinine) and AKI (> 50% increase in creatinine by postoperative calendar days 1or 2) was determined by logistic regression modelling. Existing databases were used for model development (n = 4,820; one institution) and validation (n = 6,553; 12 institutions). Acute kidney injury occurred in 9.1% (n = 437) and 9.8% (n = 645) of patients in the development and validation sets, respectively. An early rise in creatinine was related to AKI (P 1.30 (n = 127), the sensitivity, specificity, positive, and negative predictive values for AKI in the development set were 20% (95% CI, 16 to 24), 99% (95% CI, 99 to 99), 68% (95% CI, 59 to 76), and 93% (95% CI, 92 to 93), respectively. In patients undergoing cardiac surgery with cardiopulmonary bypass, an early rise in postoperative creatinine is a useful marker for the early identification of AKI patients. This could allow inclusion of such patients in clinical trials of promising therapeutic strategies that need to be initiated soon after the onset of injury.

  8. Effect of lemongrass tea consumption on estimated glomerular filtration rate and creatinine clearance rate.

    Science.gov (United States)

    Ekpenyong, Christopher E; Daniel, Nyebuk E; Antai, Atim B

    2015-01-01

    The existing research findings regarding the effects of lemongrass (Cymbopogon citratus) tea on renal function indices are conflicting and inconclusive. In the present study, we investigated the effects of infusions prepared from C citratus leaves on creatinine clearance rate (CCr) and estimated glomerular filtration rate (eGFR) in humans. One hundred five subjects (55 men and 50 women) aged 18 to 35 years were randomly assigned to groups set to orally receive infusions prepared from 2, 4, or 8 g of C citratus leaf powder once daily, for 30 days. Serum and urinary levels of urea, creatinine, pH, specific gravity, uric acid, electrolytes, diuretic indices, and eGFR were assessed at days 0, 10, and 30 after the initiation of treatment. Results obtained on days10 and 30 were compared with baseline values. CCr and eGFR decreased significantly at day 30 in both male and female subjects in all the groups and in females treated with infusion prepared from 8 g of C citratus leaf powder for 10 days. At day 10, CCr and eGFR were unchanged in those treated with infusions prepared from 2 or 4 g of the leaf powder, whereas diuretic indices (urine volume, urination frequency, diuretic action, and saliuretic indices) increased above the baseline levels. Serum and urinary creatinine levels significantly increased (P < .05) in both male and female subjects in all the groups. Serum urea significantly increased in the groups treated with infusions prepared from 4 or 8 g of the leaf powder (P < .05) for 30 days. Serum electrolytes remained unchanged, but their urinary levels increased. We observed dose- and time-dependent adverse effects of C citratus on CCr and eGFR. At a high dose or with prolonged treatment with a low dose, eGFR decrease may be followed by a decline in the other renal function indices. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  9. Increased serum urea to creatinine ratio and its negative correlation with arterial pressure in canine babesiosis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga

    2014-09-01

    The increase of the serum urea to creatinine ratio (UCR) was observed in dogs infected with Babesia canis. Previous studies have suggested that decrease of blood pressure can be one of the reasons for this phenomenon. In this work statistically significant increase of the UCR was observed in dogs with babesiosis. Comparison of the UCR between 23 azotaemic dogs and 25 non-azotaemic dogs infected with Babesia canis showed statistically significantly higher mean of the UCR in azotaemic dogs. Correlations between UCR and systolic, diastolic and mean arterial pressure (SAP, DAP and MAP) in 48 dogs infected with B. canis were negative (UCR and SAP: r = -0.3909; UCR and DAP: r = -0.3182; UCR and MAP: r = -0.3682) and statistically significant (p high, and there was no statistically significant correlation between UCR and arterial pressures in azotaemic dogs. Thus, it seems that decrease of blood pressure in dogs with babesiosis explains only partially the cause of increased UCR in infected dogs. The other authors suggested hyperureagenesis and myocardial injury as a potential reason for the increased UCR in canine babesiosis. Thus, further studies are needed to determine causes of increased UCR in dogs with babesiosis, especially on the connection between UCR changes and the concentrations of plasma cardiac troponins and ammonia, and the occurrence of occult blood on fecal examination.

  10. Successful Pregnancies Post Renal Transplantation

    Directory of Open Access Journals (Sweden)

    Alfi Adnan

    2008-01-01

    Full Text Available To evaluate the maternal and fetal outcomes in renal transplant female recipients who became pregnant from 1989 to 2005 in our center, we retrospectively studied 20 incident pregnancies in 12 renal transplant recipients; 5 (41.7 % of them from living related, 4 (33.3% from deceased, and 3 (25% from living unrelated donors. The mean age at pregnancy was 30.5 ± 4.5 years and mean interval from transplantation to pregnancy was 21 ± 5.7 months with the interval was < 1 year in one patient. The mean serum creatinine (SCr before pregnancy vs 6 months post delivery was 110 ± 24.3, and 156 ± 190 µmol/ L, respectively, (p = 0.2. All patients were normotensive during the prenatal period except two who were hypertensive, none was markedly proteinuric, and only one acute rejection episode occurred during one pregnancy. Graft loss one year post delivery occurred in 2 patients; one with elevated prenatal SCr > 132 µmol/L, and another with short interval from transplantation to pregnancy < 1 year, while the remaining 10 patients revealed current mean SCr of 105 ± 18.2 µmol/L. Complications during pregnancy inclu-ded pre-eclampsia in (25%, UTI (25%, preterm delivery < 37 weeks (30%, however, none of the pregnancies ended by abortion. Normal vaginal delivery vs cesarean section was 70% vs 30%, respectively. Gestational age at delivery was 36.3 ± 3.9 weeks, and mean fetal birth weight was 2349 ± 574 gm. Apgar score was 9-10 in all of the 20 babies, and none revealed intrauterine growth retardation or congenital anomalies. We conclude that consecutive pregnancies demons-trate long-term maternal and fetal survival and function. The major risk factors are elevated starting serum creatinine, hypertension, and short time interval from transplantation to pregnancy.

  11. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    OpenAIRE

    Pickering, John W; Frampton, Christopher M; Walker, Robert J; Shaw, Geoffrey M; Endre, Zolt?n H

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 h...

  12. The analytical change in plasma creatinine that constitutes a biologic/physiologic change.

    Science.gov (United States)

    Toffaletti, John G; Hammett-Stabler, Catherine A; Gearhart, Margaret; Roy Choudhury, Kingshuk; Handel, Elizabeth A

    2016-08-01

    had good precision, the ENZ method had the best precision, such that a change of 0.07mg/dL (6μmol/L) in serial creatinine concentrations up to 1.5mg/dL on a patient could indicate a biologic change had occurred. For the alkaline picrate methods, a measured change of creatinine of 0.23mg/dL for AP1 or 0.11mg/dL for AP2 would indicate that a physiologic change in serum/plasma creatinine has occurred. While a definite biologic change may simply represent daily variations, detecting a biologic change in creatinine more rapidly could impact the ability of creatinine to detect early and clinically significant changes in renal function. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Association of Lead Exposure, Serum Uric Acid and Parameters of Renal Function in Nigerian Lead-Exposed Workers

    Directory of Open Access Journals (Sweden)

    DD Alasia

    2010-09-01

    Full Text Available Background: The presence of hyperuricemia and renal function impairment, especially in the absence of urate stone formation is strongly suggestive of lead nephropathy. The evaluation of this association is essential in areas where lead exposure is still prevalent and uncontrolled. Objective: To determine the relationship between serum uric acid and renal function indices in lead-exposed workers. Methods: A cross-sectional study of 190 adults with occupational lead exposure and 80 adults (comparison group, matched for age and sex was performed in Port Harcourt, South-south Nigeria. Blood lead was used as the biomarker of lead exposure while serum urea, serum creatinine, urine albumin (using urine albumin:creatinine ratio, estimated glomerular filtration rate (GFR and serum uric acid were the renal function indices measured. Results: Occupationally lead-exposed subjects had a significantly (p = 0.008 higher mean±SD blood lead levels (50.37±24.58 μg/dL than the comparison group (41.40±26.85. The mean±SD serum urea (8.6±2.3 mg/dL, creatinine (1.0±0.2 mg/dL and serum uric acid (4.6±1.2 mg/dL were significantly (p < 0.01 higher in the study subjects than the comparison group (7.6±2.4, 0.9±0.2, and 3.9±1.1 mg/dL, respectively. The mean±SD creatinine clearance was significantly (p = 0.002 lower in the study subjects than the comparison group (98.9±21.3 vs. 108.2±25.2 mL/min/1.72 m2. Serum uric acid level correlated positively with serum creatinine (r = 0.134 and negatively with GFR (r = ‑0.151. Conclusion: People with occupational lead exposure are at risk of developing hyperuricemia and renal impairment.

  14. EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    J.A. Withum; S.C. Tseng; J.E. Locke

    2005-11-01

    CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dryer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the seventh in a series of topical reports, describes the results and analysis of mercury sampling performed on a 1,300 MW unit burning a bituminous coal containing three percent sulfur. The unit was equipped with an ESP and a limestone-based wet FGD to control particulate and SO2 emissions, respectively. At the time of sampling an SCR was not installed on this unit. Four sampling tests were performed in September 2003. Flue gas mercury speciation and concentrations were determined at the ESP outlet (FGD inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process stream samples for a mercury balance were collected to coincide with the flue gas measurements. The results show that the FGD inlet flue gas oxidized:elemental mercury ratio was roughly 2:1, with 66% oxidized mercury and 34% elemental mercury. Mercury removal, on a coal

  15. A comparative study on methods of improving SCR for ship detection in SAR image

    Science.gov (United States)

    Lang, Haitao; Shi, Hongji; Tao, Yunhong; Ma, Li

    2017-10-01

    Knowledge about ship positions plays a critical role in a wide range of maritime applications. To improve the performance of ship detector in SAR image, an effective strategy is improving the signal-to-clutter ratio (SCR) before conducting detection. In this paper, we present a comparative study on methods of improving SCR, including power-law scaling (PLS), max-mean and max-median filter (MMF1 and MMF2), method of wavelet transform (TWT), traditional SPAN detector, reflection symmetric metric (RSM), scattering mechanism metric (SMM). The ability of SCR improvement to SAR image and ship detection performance associated with cell- averaging CFAR (CA-CFAR) of different methods are evaluated on two real SAR data.

  16. Pretreatment Serum Cystatin C Levels Predict Renal Function, but Not Tumor Characteristics, in Patients with Prostate Neoplasia

    Directory of Open Access Journals (Sweden)

    Feilong Yang

    2017-01-01

    Full Text Available To evaluate the role of Cystatin C (Cys-C in tumorigenesis and progression of prostate cancer (PCa, we retrospectively collected the clinical information from the records of 492 benign prostatic hyperplasia (BPH, 48 prostatic intraepithelial neoplasia (PIN, and 173 PCa patients, whose disease was newly diagnosed and histologically confirmed. Pretreatment serum Cys-C levels were compared across the various groups and then analyzed to identify relationships, if any, with clinical and pathological characteristics of the PCa patient group. There were no significant differences in serum Cys-C levels among the three groups (P > 0.05. In PCa patients with normal SCr levels, patient age was correlated with serum Cys-C level (P ≤ 0.001 but did not correlate with alkaline phosphatase (AKP, lactate dehydrogenase (LDH, prostate specific antigen (PSA, Gleason score, or bone metastasis status (P > 0.05. Age and SCr contributed in part to the variations in serum Cys-C levels of PCa patients (r = 0.356, P ≤ 0.001; r = 0.520, P ≤ 0.001. In conclusion, serum Cys-C levels predict renal function in patients with prostate neoplasia, but were not a biomarker for the development of prostate neoplasia, and were not correlated with the clinicopathological characteristics of PCa.

  17. Association of high post-transplant soluble CD30 serum levels with chronic allograft nephropathy.

    Science.gov (United States)

    Grenzi, Patricia C; Campos, Érika F; Tedesco-Silva, Hélio; Felipe, Claudia R; Franco, Marcello F; Soares, Maria Fernanda; Medina-Pestana, José Osmar; Gerbase-Delima, Maria

    2013-12-01

    The purpose of this study was to evaluate the association of post-transplant soluble CD30 (sCD30) levels, isolated or in combination with of anti-HLA class II antibodies and of serum creatinine levels, with kidney graft loss due to chronic allograft nephropathy (CAN), and type of lesions in graft biopsies for cause. The study comprised 511 first kidney graft recipients, transplanted at a single center, with a graft functioning for at least 2.8 years. A single blood sample was collected from each patient. sCD30 levels were determined by ELISA, and HLA antibodies by Luminex assay. The minimum follow-up after testing was 9.3 years. High sCD30 levels, set at sCD30 ≥ 34.15 ng/mL, the presence of HLA class II antibodies, and serum creatinine ≥ 1.9 mg/dL were independently associated with CAN-graft loss (P values sCD30 levels and creatinine were independently associated with interstitial lesions. Post-transplant sCD30 serum levels, especially in conjunction with information regarding HLA class II antibodies and serum creatinine levels, provide valuable information regarding graft outcome and could be useful for the management of kidney transplant recipients. © 2013.

  18. Comparison between swallowing and chewing of garlic on levels of serum lipids, cyclosporine, creatinine and lipid peroxidation in Renal Transplant Recipients

    Directory of Open Access Journals (Sweden)

    Ghorbanihaghjo Amir

    2005-05-01

    Full Text Available Abstract Abstract Hyperlipidemia and increased degree of oxidative stress are among the important risk factors for Atherosclerosis in renal transplant recipients (RTR. The Medical treatment of hyperlipidemia in RTR because of drugs side effects has been problematic, therefore alternative methods such as using of Garlic as an effective material in cholesterol lowering and inhibition of LDL Oxidation has been noted. For evaluation of garlic effect on RTR, 50 renal transplant patients with stable renal function were selected and divided into 2 groups. They took one clove of garlic (1 gr by chewing or swallowing for two months, after one month wash-out period, they took garlic by the other route. Results indicated that although lipid profile, BUN, Cr, serum levels of cyclosporine and diastolic blood pressure did not change, Systolic blood pressure decreased from138.2 to 132.8 mmHg (p=0.001 and Malondialdehyde (MDA decreased from 2.4 to1.7 nmol/ml (p=0.009 by swallowing route, Cholesterol decreased from 205.1 to 195.3 mg/dl (p=0.03, triglyceride decreased from 195.7 to 174.8 mg/dl (p=0.008, MDA decreased from 2.5 to 1.6 nmol/ml (p=0.001, systolic blood pressure decreased from 137.5 to 129.8 mmHg (p=0.001, diastolic blood pressure decreased from 84.6 to 77.6 mmHg (p=0.001 and Cr decreased from 1.51 to 1.44 mg/dl (p=0.03 by chewing route too. However HDL, LDL and cyclosporine serum levels had no significant differences by both of swallowing and chewing routes. We conclude that undamaged garlic (swallowed had no lowering effect on lipid level of serum. But Crushed garlic (chewed reduces cholesterol, triglyceride, MDA and blood pressure. Additionally creatinine reduced without notable decrease in cyclosporine serum levels may be due to cyclosporine nephrotoxicity ameliorating effect of garlic.

  19. 21 CFR 862.1225 - Creatinine test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Creatinine test system. 862.1225 Section 862.1225....1225 Creatinine test system. (a) Identification. A creatinine test system is a device intended to measure creatinine levels in plasma and urine. Creatinine measurements are used in the diagnosis and...

  20. Urine and serum fetuin-A levels in patients with urolithiasis.

    Science.gov (United States)

    Arora, Rajat; Abrol, Nitin; Antonisamy, B; Vanitha, S; Chandrasingh, J; Kumar, Santosh; Kekre, Nitin; Devasia, Antony

    2017-01-01

    Fetuin-A is a glycoprotein secreted by liver and has been shown to inhibit extraosseous mineralization. Urolithiasis may be a manifestation in the urinary tract due to fetuin deficiency in urine. The objective of this study was to compare the 24-h urine and serum fetuin-A levels of patients with and without urolithiasis. Serum and 24-h urine fetuin-A levels were measured in 41 patients with bilateral, multiple, or recurrent urinary tract calculi (Group A) and 41 matched controls with no calculi (Group B). Fetuin levels were measured by enzyme linked immunosorbent assay. Serum and urine fetuin-A levels in the two groups were compared. The median (range) 24-h urine fetuin-A value in Group A was 11.9 (1.12-221) mg/day and in Group B was 37.7 (1.28-125) mg/day. This difference was statistically significant (Mann-Whitney test, P = 0.0169). The median (range) serum fetuin-A in Group A was 0.67 (0.05-2.68) g/L and in Group B was 0.99 (0.01-5.5) g/L. The difference between serum values in the two arms was not statistically significant (Mann-Whitney test, P = 0.1817). However, the serum creatinine-adjusted mean log serum fetuin and urine fetuin were significantly different in the two arms ( P = 0.003). The mean ± standard deviation (range) serum creatinine in Group A was 0.98 ± 0.25 (0.56-1.58) mg% and in Group B was 0.83 ± 0.16 (0.58-1.18) mg% (two sample t -test, P = 0.0031). Patients with urolithiasis have lower urine fetuin-A and creatinine-adjusted serum fetuin-A levels.

  1. Serum amylase and lipase activities after exploratory laparotomy in dogs.

    Science.gov (United States)

    Bellah, J R; Bell, G

    1989-09-01

    Serum amylase and lipase activities and creatinine concentration were determined before surgery, and at 1 and 2 days after exploratory laparotomy in 24 dogs. Examination of all viscera was done during each laparotomy, but a surgical procedure was not performed. The mean serum activities for lipase were: before surgery, 0.71 (0.0 to 2.0) Cherry Crandall units (CCU)/L; 1 day after surgery, 2.1 (0.0 to 4.5) CCU/L; and 2 days after surgery, 1.19 (0.0 to 3.9) CCU/L. The mean serum activities for amylase were: before surgery, 1,958 (1,027 to 3,426) IU/L; 1 day after surgery, 1,538 (937 to 2,659) IU/L; and 2 days after surgery, 1,663 (1,066 to 2,274) IU/L. Serum creatinine concentrations before surgery, 1 day after surgery, and 2 days after surgery were 0.88 (0.2 to 1.7) mg/dl, 0.78 (0.4 to 1.3) mg/dl, and 0.78 (0.3 to 1.3) mg/dl, respectively. Mean preoperative, day-1, and day-2 serum amylase activities and serum creatinine concentrations did not differ significantly from each other. Mean preoperative and day-2 serum lipase activities did not differ significantly; however, mean serum lipase activity was significantly greater when day 1 activities were compared with preoperative activities (P = 0.0002). Post-mortem examinations revealed no gross or histologic evidence of pancreatitis in any dog. The results of this study show that a 3 or more fold increase in serum lipase activity may occur after routine exploratory laparotomy in dogs without clinical signs or gross evidence of pancreatitis. Histologic evidence of pancreatitis was not found in the right pancreatic lobes in any dog.

  2. Are Surrogate Assumptions and Use of Diuretics Associated with Diagnosis and Staging of Acute Kidney Injury after Cardiac Surgery?

    Science.gov (United States)

    Hussein, Hayder K.; Prabhu, Mahesh; Kanagasundaram, N. Suren

    2012-01-01

    Summary Background and objectives This study measured the association between the Acute Kidney Injury Network (AKIN) diagnostic and staging criteria and surrogates for baseline serum creatinine (SCr) and body weight, compared urine output (UO) with SCr criteria, and assessed the relationships between use of diuretics and calibration between criteria and prediction of outcomes. Design, setting, participants, & measurements This was a retrospective cohort study using prospective measurements of SCr, hourly UO, body weight, and drug administration records from 5701 patients admitted, after cardiac surgery, to a cardiac intensive care unit between 1995 and 2006. Results More patients (n=2424, 42.5%) met SCr diagnostic criteria with calculated SCr assuming a baseline estimated GFR of 75 ml/min per 1.73 m2 than with known baseline SCr (n=1043, 18.3%). Fewer patients (n=484, 8.5%) met UO diagnostic criteria with assumed body weight (70 kg) than with known weight (n=624, 10.9%). Agreement between SCr and UO criteria was fair (κ=0.28; 95% confidence interval 0.25–0.31). UO diagnostic criteria were specific (0.95; 0.94–0.95) but insensitive (0.36; 0.33–0.39) compared with SCr. Intravenous diuretics were associated with higher probability of falling below the UO diagnostic threshold compared with SCr, higher 30-day mortality (relative risk, 2.27; 1.08–4.76), and the need for renal support (4.35; 1.82–10.4) compared with no diuretics. Conclusions Common surrogates for baseline estimated GFR and body weight were associated with misclassification of AKIN stage. UO criteria were insensitive compared with SCr. Intravenous diuretic use further reduced agreement and confounded association between AKIN stage and 30-day mortality or need for renal support. PMID:22246280

  3. Comparison of renal function assessment by cystatin c and creatinine based equations for e-gfr in type 2 diabetics in different stages of albuminuria

    International Nuclear Information System (INIS)

    Qamar, A.; Ahmad, T.M.; Hayat, A.; Khan, M.A.; Rehman, S. Z.

    2017-01-01

    To compare e-GFR estimated by creatinine or cystatin C based and combined creatinine and cystatin C based equations in type 2 diabetics in different stages of albuminuria. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Chemical Pathology, Army Medical College Rawalpindi in collaboration with endocrinology outpatient department Military Hospital Rawalpindi, from Nov 2015 to Nov 2016. Material and Methods: A total of 119 type 2 diabetic subjects of either gender, aged 30- 60 years were enrolled in the study with duration of diabetes less than 15 years and were divided into further sub groups on the basis of degree of albuminuria determined by spot urine albumin to creatinine ratio (uACR). Fifty age matched disease free controls with no history of any systemic disease were also included in the study. Known patients of type 1 diabetes, chronic inflammatory disorders, uncontrolled hypertension, thyroid disease, chronic kidney disease, on lipid lowering drugs, steroids, ACE inhibitors and pregnant ladies were excluded from the study. Serum creatinine serum cystatin C were assessed on fully automated chemistry analyzer selectra. E-GFR was calculated by online GFR calculator by National Kidney Foundation. Comparison of means of e-GFR calculated by various equations was carried out by one way ANOVA and post-hoc Tukey tests. Degree of agreement between various equations for the estimation of GFR was assessed by kappa statistics. A p-value less than 0.05 were considered statistically significant. Results: Mean e-GFR (ml/min/1.73m2) was lowest in cystatin C based CKD-EPI equation (89.56 +- 39.84) followed by combined cystatin C and creatinine based CKD-EPI (92.34 +- 37.88). Values of e-GFR by creatinine based CKD-EPI equation (95.84 +- 27.24), and by creatinine based MDRD equation (105.37 +- 64.98) were both higher. In creatinine based MDRD, equation normo albuminuria and micro albuminuria groups did not show statistically

  4. Evaluation of determining serum α1-microglobulin level for early diagnosis of the diabetic retinopathy

    International Nuclear Information System (INIS)

    Jiang Quanxin; Han Laixin; Yin Shihua; Meng Lingqiang

    1995-01-01

    The serum α 1 -MG, β 2 -MG and other indices of 35 patients with NIDDM and 15 patients with diabetic retinopathy are determined. The results show that not only the serum α 1 -MG, β 2 -MG of all patients are obviously higher than the normal, but the serum α 1 -MG rises earlier than β 2 -MG. By means of correlation analysis, the serum β 2 -MG is significantly correlative with β 2 -MG and Scr(r = 0.673, r = 0.608). All those indicate that the level of the serum α 1 -MG may be a reliable and sensitive index to the diabetic retinopathy in the early diagnosis

  5. Protective Effect of Aqueous and Ethanolic Extracts of Portulaca Oleracea Against Cisplatin Induced Nephrotoxicity

    Directory of Open Access Journals (Sweden)

    Gholamreza Karimi

    2010-04-01

    Full Text Available Objective(sPortulaca oleracea L. is a herbaceous weed from portulacaceae family. It can be found in many parts of the world. Modern pharmacological studies have demonstrated that P. oleracea have antioxidant effects. The protective effect of aqueous and ethanolic extract of P. oleracea against cisplatin-induced renal toxicity was studied in rats.Materials and MethodsSingle intraperitoneal injection of 4 mg/kg cisplatin was administrated to rats. After 5 days, blood urea nitrogen (BUN and serum creatinine (Scr concentration were determined. Effect of aqueous and ethanolic extracts, before and after cisplatin injection on BUN and Scr, as well as morphological renal damage, was evaluated. ResultsIt was indicated that treatment with aqueous and ethanolic extracts of P. oleracea in the highest dose (0.8 and 2 g/ kg, 6 and 12 hr before cisplatin injection reduced BUN and Scr. Tubular necrotic damage was not observed either. ConclusionResults suggest that P. oleracea extract may protect against cisplatin-induced renal toxicity and might serve as a novel combination agent with cisplan to limit renal injury.

  6. Urea thermolysis and NOx reduction with and without SCR catalysts

    International Nuclear Information System (INIS)

    Fang, Howard L.; DaCosta, Herbert F.M.

    2003-01-01

    Urea-selective catalytic reduction (SCR) has been a leading contender for removal of nitrogen oxides (deNO x ) from diesel engine emissions. Despite its advantages, the SCR technology faces some critical detriments to its catalytic performance such as catalyst surface passivation (caused by deposit formation) and consequent stoichiometric imbalance of the urea consumption. Deposit formation deactivates catalytic performance by not only consuming part of the ammonia produced during urea decomposition but also degrading the structural and thermal properties of the catalyst surface. We have characterized the urea thermolysis with and without the urea-SCR catalyst using both spectroscopic (DRIFTS and Raman) and thermal techniques (thermal gravimetric analysis (TGA) and differential scanning calorimetry (DSC)) to identify the deposit components and their corresponding thermal properties. Urea thermolysis exhibits two decomposition stages, involving ammonia generation and consumption, respectively. The decomposition after the second stage leads to the product of melamine complexes, (HNC=NH) x (HNCO) y , that hinder catalytic performance. The presence of catalyst accompanied with a good spray of the urea solution helps to eliminate the second stage. In this work, kinetics of the direct reduction of NO x by urea is determined and the possibility of using additives to the urea solution in order to rejuvenate the catalyst surface and improve its performance will be discussed

  7. SCR-1: Design and construction of a small modular stellarator for magnetic confinement of plasma

    International Nuclear Information System (INIS)

    Barillas, L; Vargas, V I; Alpizar, A; Asenjo, J; Carranza, J M; Cerdas, F; Gutiérrez, R; Monge, J I; Mora, J; Morera, J; Peraza, H; Rojas, C; Rozen, D; Saenz, F; Sánchez, G; Sandoval, M; Trimiño, H; Umaña, J; Villegas, L F; Queral, V

    2014-01-01

    This paper describes briefly the design and construction of a small modular stellarator for magnetic confinement of plasma, called Stellarator of Costa Rica 1, or SCR-1; developed by the Plasma Physics Group of the Instituto Tecnológico de Costa Rica, PlasmaTEC. The SCR-1 is based on the small Spanish stellarator UST 1 , created by the engineer Vicente Queral. The SCR-1 will employ stainless steel torus-shaped vacuum vessel with a major radius of 460.33 mm and a cross section radius of 110.25 mm. A typical SCR-1 plasma will have an average radius 42.2 mm and a volume of 8 liters (0.01 m 3 ), and an aspect ratio of 5.7. The magnetic resonant field will be 0.0878 T, and a period of 2 (m=2) with a rotational transform of 0.3. The magnetic field will be provided by 12 modular coils, with 8 turns each, with an electrical current of 8704 A per coil (1088 A per turn of each coil). This current will be fed by a bank of cell batteries. The plasma will be heated by ECRH with magnetrons of a total power of 5 kW, in the first harmonic at 2.45 GHz. The expected electron temperature and density are 15 eV and 10 17 m −3 respectively with an estimated confinement time of 7.30 x 10 −4 ms. The initial diagnostics on the SCR-1 will consist of a Langmuir probe, a heterodyne microwave interferometer, and a field mapping system. The first plasma of the SCR-1 is expected at the end of 2011.

  8. Dexamethasone Modifies Cystatin C-Based Diagnosis of Acute Kidney Injury During Cisplatin-Based Chemotherapy

    Directory of Open Access Journals (Sweden)

    Timothy J. Pianta

    2017-03-01

    Full Text Available Background/Aims: Plasma cystatin C (pCysC may be superior to serum creatinine (sCr as a surrogate of GFR. However, the performance of pCysC for diagnosing acute kidney injury (AKI after cisplatin-based chemotherapy is potentially affected by accompanying corticosteroid anti-emetic therapy and hydration. Methods: In a prospective observational study pCysC, sCr, urinary kidney injury molecule-1 (KIM-1, and urinary clusterin were measured over 2 weeks in 27 patients given first-cycle chemotherapy. The same variables were measured over 2 weeks in Sprague–Dawley rats given a single intraperitoneal injection of dexamethasone, cisplatin, or both, and in controls. Results: In patients, pCysC increases were greater than sCr 41% vs. 16%, mean paired difference 25% (95% CI: 16–34%], relative increases were ≥ 50% in 9 patients (35% for pCysC compared with 2 (8% for sCr (p = 0.04 and increases in sCr were accompanied by increased KIM-1 and clusterin excretion, but increases in pCysC alone were not. In rats, dexamethasone administration produced dose-dependent increases in pCysC (and augmented cisplatin-induced increases in pCysC, but did not augment histological injury, increases in sCr, or KIM-1 and clusterin excretion. Conclusions: In the presence of dexamethasone, elevation of pCysC does not reliably diagnose AKI after cisplatin-based chemotherapy.

  9. Association of Serum Adropin Concentrations with Diabetic Nephropathy

    Directory of Open Access Journals (Sweden)

    Wenchao Hu

    2016-01-01

    Full Text Available Objective. Adropin is a newly identified regulatory protein encoded by the Enho gene and is critically involved in energy homeostasis and insulin sensitivity. This study aims to determine the correlation of serum adropin concentrations with diabetic nephropathy (DN. Methods. This study consisted of 245 patients with type 2 diabetes mellitus (T2DM and 81 healthy subjects. Then T2DM patients were divided into normoalbuminuria, microalbuminuria, and macroalbuminuria subgroups based on urine albumin to creatinine ratio (ACR. Results. T2DM patients showed significantly lower serum adropin concentrations than those in the controls. T2DM patients with macroalbuminuria had significantly decreased serum adropin concentrations compared with the other three groups. In addition, T2DM patients with microalbuminuria showed lower serum adropin concentrations than those in patients with normoalbuminuria. Logistic regression analysis showed that serum adropin was correlated with decreased risk of developing T2DM and DN. Pearson correlation analysis indicated that serum adropin was negatively correlated with body mass index (BMI, blood urea nitrogen, creatinine, and ACR and positively correlated with glomerular filtration rate. Furthermore, multiple linear regression analysis showed that BMI and ACR were negatively correlated with serum adropin levels. Conclusion. Serum adropin concentrations are negatively associated with renal function. Adropin may be implicated in the pathogenesis of DN development.

  10. Changes in serum biochemical factors associated with opium addiction after addiction desertion.

    Science.gov (United States)

    Afarinesh, Mohammad Reza; Haghpanah, Tahereh; Divsalar, Kouros; Dehyadegary, Elham; Shaikh-Aleslami, Azar; Mahmoodi, Majid

    2014-01-01

    The long time use of opium has some effects on serums biochemical factors, the determination of this variation is a new approach in understanding off addiction and relive of drug abuser health. Hence in this study, these indicators in person who were withdrawing of opium have been studied. In this cross-sectional study bloods biochemical factors such as fasting blood sugar (FBS), sodium (Na), calcium (Ca), uric acid (UA), blood urea nitrogen (BUN), creatinine, cholesterol, total protein, and fibrinogen in three groups serum were studied: (1) Who had been permanent opium users more than 2 years (case). (2) Dependent person who has taken one month addiction withdrawal course (control). (3) A healthy group that had been demographically similar to the other groups. According to these study findings, FBS serum level in the case group is lower than control group. Serum level of Na, creatinine, and blood triglyceride (TG) in case study are higher than group control. Concentration of potassium, Ca, UA, BUN, cholesterol, total serum protein, fibrinogen, and thrombin time in case study and group control showed no significant difference. Also, in withdrawing case serum level of Na, Ca, UA, BUN, creatinine, and TG significantly increase and thrombin time decrease. According to this study not only the longtime use of opium but also opium with drawerin opium dependent people can change their serum biochemical factors. So recognition, treatment, and prevention of this change could be a new step in improving of health and condition of patients.

  11. Experimental demonstration of a new model-based SCR control strategy for cleaner heavy-duty diesel engines

    NARCIS (Netherlands)

    Willems, F.P.T.; Cloudt, R.P.M.

    2011-01-01

    Selective catalytic reduction (SCR) is a promising diesel aftertreatment technology that enables low nitrogen oxides (NOx) tailpipe emissions with relatively low fuel consumption. Future emission legislation is pushing the boundaries for SCR control systems to achieve high NOx conversion within a

  12. Performance of Chronic Kidney Disease Epidemiology Collaboration Creatinine-Cystatin C Equation for Estimating Kidney Function in Cirrhosis

    Science.gov (United States)

    Mindikoglu, Ayse L.; Dowling, Thomas C.; Weir, Matthew R.; Seliger, Stephen L.; Christenson, Robert H.; Magder, Laurence S.

    2013-01-01

    Conventional creatinine-based glomerular filtration rate (GFR) equations are insufficiently accurate for estimating GFR in cirrhosis. The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) recently proposed an equation to estimate GFR in subjects without cirrhosis using both serum creatinine and cystatin C levels. Performance of the new CKD-EPI creatinine-cystatin C equation (2012) was superior to previous creatinine- or cystatin C-based GFR equations. To evaluate the performance of the CKD-EPI creatinine-cystatin C equation in subjects with cirrhosis, we compared it to GFR measured by non-radiolabeled iothalamate plasma clearance (mGFR) in 72 subjects with cirrhosis. We compared the “bias”, “precision” and “accuracy” of the new CKD-EPI creatinine-cystatin C equation to that of 24-hour urinary creatinine clearance (CrCl), Cockcroft-Gault (CG) and previously reported creatinine- and/or cystatin C-based GFR-estimating equations. Accuracy of CKD-EPI creatinine-cystatin C equation as quantified by root mean squared error of difference scores [differences between mGFR and estimated GFR (eGFR) or between mGFR and CrCl, or between mGFR and CG equation for each subject] (RMSE=23.56) was significantly better than that of CrCl (37.69, P=0.001), CG (RMSE=36.12, P=0.002) and GFR-estimating equations based on cystatin C only. Its accuracy as quantified by percentage of eGFRs that differed by greater than 30% with respect to mGFR was significantly better compared to CrCl (P=0.024), CG (P=0.0001), 4-variable MDRD (P=0.027) and CKD-EPI creatinine 2009 (P=0.012) equations. However, for 23.61% of the subjects, GFR estimated by CKD-EPI creatinine-cystatin C equation differed from the mGFR by more than 30%. CONCLUSIONS The diagnostic performance of CKD-EPI creatinine-cystatin C equation (2012) in patients with cirrhosis was superior to conventional equations in clinical practice for estimating GFR. However, its diagnostic performance was substantially worse than

  13. Analysis of clinical factors for the determination of optimal serum level of thyrotropin after recombinant human thyroid-stimulating hormone administration

    International Nuclear Information System (INIS)

    Son, Seung Hyun; Lee, Sang Woo; Jung, Ji Hoon; Kim, Choon Young; Kim, Do Hoon; Jeong, Shin Young; Ahn, Byeong Cheol; Lee, Jae Tae

    2015-01-01

    To determine the optimal levels of thyroid-stimulating hormone (TSH) levels after administration of recombinant human TSH (rhTSH) to patients with differentiated thyroid cancer (DTC), we have analyzed the clinical parameters that affected the degree of the increase in serum levels of TSH. We retrospectively analyzed 276 patients with differentiated thyroid cancer (DTC), post-thyroidectomy and remnant ablation. Pearson’s correlation coefficient test was used to evaluate the correlation between serum levels of TSH after rhTSH stimulation and various clinical factors, including age, sex, height, weight, body mass index (BMI), body surface area (BSA), serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate (GFR). Linear regression analysis was used to determine the predictors of the degree of increase in serum TSH level after rhTSH stimulation. After the rhTSH injections, all subjects achieved TSH levels of >30 μU/mL, with a mean of 203.8 ± 83.4 μU/mL. On univariate analysis, age (r = 0.255) and serum creatinine (r = 0.169) level were positive predictors for higher levels of serum TSH after rhTSH stimulation, while weight (r = –0.239), BMI (r = –0.223), BSA (r = –0.217), and estimated GFR (r = –0.199) were negative predictors. Multiple linear regression analysis revealed that serum creatinine was the most powerful independent predictor for serum levels of TSH, followed by age, BSA, and BMI. An increment in serum TSH after rhTSH stimulation was significantly affected by age, BSA, BMI, and creatinine, with creatinine being the most powerful predictor. By understanding the difference in the increased levels of TSH in various subjects, their dose of rhTSH can be adjusted during scheduling for radioiodine ablation, or during follow-up (recurrence surveillance) after surgery and ablation

  14. Analysis of clinical factors for the determination of optimal serum level of thyrotropin after recombinant human thyroid-stimulating hormone administration

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seung Hyun; Lee, Sang Woo; Jung, Ji Hoon; Kim, Choon Young; Kim, Do Hoon; Jeong, Shin Young; Ahn, Byeong Cheol; Lee, Jae Tae [Dept. of Nuclear Medicine, Kyungpook National University Medical Center and School of Medicine, Daegu (Korea, Republic of)

    2015-12-15

    To determine the optimal levels of thyroid-stimulating hormone (TSH) levels after administration of recombinant human TSH (rhTSH) to patients with differentiated thyroid cancer (DTC), we have analyzed the clinical parameters that affected the degree of the increase in serum levels of TSH. We retrospectively analyzed 276 patients with differentiated thyroid cancer (DTC), post-thyroidectomy and remnant ablation. Pearson’s correlation coefficient test was used to evaluate the correlation between serum levels of TSH after rhTSH stimulation and various clinical factors, including age, sex, height, weight, body mass index (BMI), body surface area (BSA), serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate (GFR). Linear regression analysis was used to determine the predictors of the degree of increase in serum TSH level after rhTSH stimulation. After the rhTSH injections, all subjects achieved TSH levels of >30 μU/mL, with a mean of 203.8 ± 83.4 μU/mL. On univariate analysis, age (r = 0.255) and serum creatinine (r = 0.169) level were positive predictors for higher levels of serum TSH after rhTSH stimulation, while weight (r = –0.239), BMI (r = –0.223), BSA (r = –0.217), and estimated GFR (r = –0.199) were negative predictors. Multiple linear regression analysis revealed that serum creatinine was the most powerful independent predictor for serum levels of TSH, followed by age, BSA, and BMI. An increment in serum TSH after rhTSH stimulation was significantly affected by age, BSA, BMI, and creatinine, with creatinine being the most powerful predictor. By understanding the difference in the increased levels of TSH in various subjects, their dose of rhTSH can be adjusted during scheduling for radioiodine ablation, or during follow-up (recurrence surveillance) after surgery and ablation.

  15. Serum total proteins and creatinine levels in experimental gambian ...

    African Journals Online (AJOL)

    Attempt was therefore made to evaluate the effect of two strains of Trypanosoma brucei gambiense on total proteins and other serum biochemical parameters using vervet monkeys as a model. The outcome of both strains in vervet monkeys was traumatic as the monkeys died from infection 12 – 15 weeks post infection while ...

  16. Serum Cistatin C in patients with delayed graft function

    Directory of Open Access Journals (Sweden)

    Todor Gruev

    2006-04-01

    Full Text Available Despite recent studies showing that serum Cystatin C(CysC is a better marker for glomerular filtration rate (GFR than the ubiquitously used creatinine, the clinical utility of this remains to be evaluated. This marker is very sensitive for alograft function after renal transplantation. Concentration of CysC was compared with that of creatinine. Decreased renal function was followed in 64 transplanted patients. Plasma CysC significantly correlated (r=0.625, p<0.001 with creatinine in healthy controls. In these patients the mean plasma creatinine and Cystatin C concentrations were: 81+/-13 mmol/L,0.90 +/-0.22 mg/L, respectively. Plasma Cystatin C and creatinine significantly correlated throughout the post-transplantation period (r=0.686, p<0.001, but we confirmed differences between kinetics of these parameters. In the first four days after transplantation the CysC concentration was normalized faster than creatinine concentration. Development of acute rejection episode ( between 5 and 7 days showed high sensitivity and specificity of the changes of CysC compared with those of creatinine

  17. Impact of Different Creatinine Measurement Methods on Liver Transplant Allocation

    Science.gov (United States)

    Kaiser, Thorsten; Kinny-Köster, Benedict; Bartels, Michael; Parthaune, Tanja; Schmidt, Michael; Thiery, Joachim

    2014-01-01

    Introduction The model for end-stage liver disease (MELD) score is used in many countries to prioritize organ allocation for the majority of patients who require orthotopic liver transplantation. This score is calculated based on the following laboratory parameters: creatinine, bilirubin and the international normalized ratio (INR). Consequently, high measurement accuracy is essential for equitable and fair organ allocation. For serum creatinine measurements, the Jaffé method and enzymatic detection are well-established routine diagnostic tests. Methods A total of 1,013 samples from 445 patients on the waiting list or in evaluation for liver transplantation were measured using both creatinine methods from November 2012 to September 2013 at the university hospital Leipzig, Germany. The measurements were performed in parallel according to the manufacturer’s instructions after the samples arrived at the institute of laboratory medicine. Patients who had required renal replacement therapy twice in the previous week were excluded from analyses. Results Despite the good correlation between the results of both creatinine quantification methods, relevant differences were observed, which led to different MELD scores. The Jaffé measurement led to greater MELD score in 163/1,013 (16.1%) samples with differences of up to 4 points in one patient, whereas differences of up to 2 points were identified in 15/1,013 (1.5%) samples using the enzymatic assay. Overall, 50/152 (32.9%) patients with MELD scores >20 had higher scores when the Jaffé method was used. Discussion Using the Jaffé method to measure creatinine levels in samples from patients who require liver transplantation may lead to a systematic preference in organ allocation. In this study, the differences were particularly pronounced in samples with MELD scores >20, which has clinical relevance in the context of urgency of transplantation. These data suggest that official recommendations are needed to determine which

  18. Effects of low-molecular-weight-chitosan on the adenine-induced chronic renal failure rats in vitro and in vivo

    Science.gov (United States)

    Zhi, Xuan; Han, Baoqin; Sui, Xianxian; Hu, Rui; Liu, Wanshun

    2015-02-01

    The effects of low-molecular-weight-chitosan (LMWC) on chronic renal failure (CRF) rats induced by adenine were investigated in vivo and in vitro. Chitosan were hydrolyzed using chitosanase at pH 6-7 and 37° for 24 h to obtain LMWC. In vitro, the effect of LMWC on the proliferation of renal tubular epithelial cells (RTEC) showed that it had no cytotoxic effect and could promote cell growth. For the in vivo experiment, chronic renal failure rats induced by adenine were randomly divided into control group, Niaoduqing group, and high-, medium- and low-dose LMWC groups. For each group, we detected serum creatinine (SCR), blood urea nitrogen (BUN), and total superoxide dismutase (T-SOD), glutathione oxidase (GSH-Px) activities of renal tissue, and obtained the ratio of kidney weight/body weight, pathological changes of kidney. The levels of serum SCR, BUN were higher in the adenine-induced rats than those in the control group, indicating that the rat chronic renal failure model worked successfully. The results after treatment showed that LMWC could reduce the SCR and BUN levels and enhance the activities/levels of T-SOD and GSH-PX in kidney compared to control group. Histopathological examination revealed that adenine-induced renal alterations were restored by LMWC at three tested dosages, especially at the low dosage of 100 mg kg-1 d-1.

  19. The development of a point of care creatinine measurement using disposable ready to use microchip capillary electrophoresis

    NARCIS (Netherlands)

    Ávila Muñoz, Mónica; Eijkel, Jan C.T.; Floris, J.; Staal, S.S.; Ríos, Ángel; van den Berg, Albert

    2011-01-01

    We report on the determination of creatinine in human serum using a point-of-care device suitable for the use by untrained operators, the Medimate Multireader®. This device is based on electrophoretic separation and conductivity detection and its prefilled microfluidic chip has a single opening for

  20. The optimal definition of contrast-induced acute kidney injury for prediction of inpatient mortality in patients undergoing percutaneous coronary interventions.

    Science.gov (United States)

    Parsh, Jessica; Seth, Milan; Briguori, Carlo; Grossman, Paul; Solomon, Richard; Gurm, Hitinder S

    2016-05-01

    It is unknown which definition of contrast-induced acute kidney injury (CI-AKI) in the setting of percutaneous coronary interventions is best associated with inpatient mortality and whether this association is stable across patients with various preprocedural serum creatinine (SCr) values. We applied logistic regression models to multiple CI-AKI definitions used by the Kidney Disease Improving Global Outcomes guidelines and previously published studies to examine the impact of preprocedural SCr on a candidate definition's correlation with the adverse outcome of inpatient mortality. We used likelihood ratio tests to examine candidate definitions and identify those where association with inpatient mortality remained constant regardless of preprocedural SCr. These definitions were assessed for specificity, sensitivity, and positive and negative predictive values to identify an optimal definition. Our study cohort included 119,554 patients who underwent percutaneous coronary intervention in Michigan between 2010 and 2014. Most commonly used definitions were not associated with inpatient mortality in a constant fashion across various preprocedural SCr values. Of the 266 candidate definitions examined, 16 definition's association with inpatient mortality was not significantly altered by preprocedural SCr. Contrast-induced acute kidney injury defined as an absolute increase of SCr ≥0.3 mg/dL and a relative SCr increase ≥50% was selected as the optimal candidate using Perkins and Shisterman decision theoretic optimality criteria and was highly predictive of and specific for inpatient mortality. We identified the optimal definition for CI-AKI to be an absolute increase in SCr ≥0.3 mg/dL and a relative SCr increase ≥50%. Further work is needed to validate this definition in independent studies and to establish its utility for clinical trials and quality improvement efforts. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Effects of NOX Storage Component on Ammonia Formation in TWC for Passive SCR NOX Control in Lean Gasoline Engines

    Energy Technology Data Exchange (ETDEWEB)

    Prikhodko, Vitaly Y. [ORNL; Pihl, Josh A. [ORNL; Toops, Todd J. [ORNL; Parks, II, James E. [ORNL

    2018-04-01

    A prototype three-way catalyst (TWC) with NOX storage component was evaluated for ammonia (NH3) generation on a 2.0-liter BMW lean burn gasoline direct injection engine as a component in a passive ammonia selective catalytic reduction (SCR) system. The passive NH3 SCR system is a potential approach for controlling nitrogen oxides (NOX) emissions from lean burn gasoline engines. In this system, NH3 is generated over a close-coupled TWC during periodic slightly-rich engine operation and subsequently stored on an underfloor SCR catalyst. Upon switching to lean, NOX passes through the TWC and is reduced by the stored NH3 on the SCR catalyst. Adding a NOX storage component to a TWC provides two benefits in the context of a passive SCR system: (1) enabling longer lean operation by storing NOX upstream and preserving NH3 inventory on the downstream SCR catalyst; and (2) increasing the quantity and rate of NH3 production during rich operation. Since the fuel penalty associated with passive SCR NOX control depends on the fraction of time that the engine is running rich rather than lean, both benefits (longer lean times and shorter rich times achieved via improved NH3 production) will decrease the passive SCR fuel penalty. However, these benefits are primarily realized at low to moderate temperatures (300-500 °C), where the NOX storage component is able to store NOX, with little to no benefit at higher temperatures (>500 °C), where NOX storage is no longer effective. This study discusses engine parameters and control strategies affecting the NH3 generation over a TWC with NOX storage component.

  2. A particle filter for ammonia coverage ratio and input simultaneous estimations in Diesel-engine SCR system.

    Science.gov (United States)

    Sun, Kangfeng; Ji, Fenzhu; Yan, Xiaoyu; Jiang, Kai; Yang, Shichun

    2018-01-01

    As NOx emissions legislation for Diesel-engines is becoming more stringent than ever before, an aftertreatment system has been widely used in many countries. Specifically, to reduce the NOx emissions, a selective catalytic reduction(SCR) system has become one of the most promising techniques for Diesel-engine vehicle applications. In the SCR system, input ammonia concentration and ammonia coverage ratio are regarded as essential states in the control-oriental model. Currently, an ammonia sensor placed before the SCR Can is a good strategy for the input ammonia concentration value. However, physical sensor would increase the SCR system cost and the ammonia coverage ratio information cannot be directly measured by physical sensor. Aiming to tackle this problem, an observer based on particle filter(PF) is investigated to estimate the input ammonia concentration and ammonia coverage ratio. Simulation results through the experimentally-validated full vehicle simulator cX-Emission show that the performance of observer based on PF is outstanding, and the estimation error is very small.

  3. Influência da temperatura e do tempo de armazenamento nas dosagens bioquímicas de uréia e creatinina em soro ou plasma caninos Effect of temperature and storage time on urea and creatinine dosages from canine serum or plasma

    Directory of Open Access Journals (Sweden)

    S.T. Fernandes

    2001-12-01

    Full Text Available O trabalho teve como objetivos avaliar algumas condições de estocagem de soro e de plasma com EDTA 10% utilizados para determinação dos valores de uréia e creatinina em cães, e avaliar a possibilidade de substituir o soro pelo plasma conservado com EDTA 10%. Foram realizadas 3600 análises (1800 amostras de soro e 1800 de plasma com amostras que permaneceram em temperaturas ambiente, de refrigeração e de congelamento. As análises foram realizadas imediatamente após a obtenção da amostra (tempo 0 e após 2, 6, 12, 24, 72 horas e 30 e 60 dias após a coleta do sangue. Os resultados permitiram concluir que a uréia conservou-se por mais tempo na amostra sérica refrigerada até 30 dias e a creatinina na amostra sérica congelada até 72h. O soro mostrou mais estabilidade que o plasma em todas as condições de estoque estabelecidas.Aiming to evaluating some conditions of EDTA 10% serum and plasma storage for urea and creatinine values determinations in canines as well as analyzing the possibility of serum substitution by plasma, a total of 3600 samples (1800 serum and 1800 of plasma were analyzed at room, refrigeration and freezing temperatures. Different time intervals were used in the analysis: immediately after sampling (time 0, and at 2, 6, 12, 24, and 72 hours, and 30 and 60 days after the blood collection. The data showed that urea remains conserved for more time in the refrigerated serum sample until 30 days and the creatinine in the frozen serum sample until 72 hours. Serum showed more stability than plasma in all storage conditions established.

  4. Modified Creatinine Index and the Risk of Bone Fracture in Patients Undergoing Hemodialysis: The Q-Cohort Study.

    Science.gov (United States)

    Yamada, Shunsuke; Taniguchi, Masatomo; Tokumoto, Masanori; Yoshitomi, Ryota; Yoshida, Hisako; Tatsumoto, Narihito; Hirakata, Hideki; Fujimi, Satoru; Kitazono, Takanari; Tsuruya, Kazuhiko

    2017-08-01

    Hemodialysis patients are at increased risk for bone fracture and sarcopenia. There is close interplay between skeletal muscle and bone. However, it is still unclear whether lower skeletal muscle mass increases the risk for bone fracture. Cross-sectional study and prospective longitudinal cohort study. An independent cohort of 78 hemodialysis patients in the cross-sectional study and 3,030 prevalent patients undergoing maintenance hemodialysis prospectively followed up for 4 years. Skeletal muscle mass measured by bioelectrical impedance analysis (BIA) and modified creatinine index, an estimate of skeletal muscle mass based on age, sex, Kt/V for urea, and serum creatinine level. Bone fracture at any site. In the cross-sectional study, modified creatinine index was significantly correlated with skeletal muscle mass measured by BIA. During a median follow-up of 3.9 years, 140 patients had bone fracture. When patients were divided into sex-specific quartiles based on modified creatinine index, risk for bone fracture estimated by a Fine-Gray proportional subdistribution hazards model with all-cause death as a competing risk was significantly higher in the lower modified creatinine index quartiles (Q1 and Q2) compared to the highest modified creatinine index quartile (Q4) as the reference value in both sexes (multivariable-adjusted HRs for men were 7.81 [95% CI, 2.63-23.26], 5.48 [95% CI, 2.08-14.40], 2.24 [95% CI, 0.72-7.00], and 1.00 [P for trend creatinine index; no data for residual kidney function and fracture sites and causes. Modified creatinine index was correlated with skeletal muscle mass measured by BIA. Lower modified creatinine index was associated with increased risk for bone fracture in male and female hemodialysis patients. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  5. Changes in Serum Biochemical Factors Associated with Opium Addiction after Addiction Desertion

    Science.gov (United States)

    Afarinesh, Mohammad Reza; Haghpanah, Tahereh; Divsalar, Kouros; Dehyadegary, Elham; Shaikh-Aleslami, Azar; Mahmoodi, Majid

    2014-01-01

    Background The long time use of opium has some effects on serums biochemical factors, the determination of this variation is a new approach in understanding off addiction and relive of drug abuser health. Hence in this study, these indicators in person who were withdrawing of opium have been studied. Methods In this cross-sectional study bloods biochemical factors such as fasting blood sugar (FBS), sodium (Na), calcium (Ca), uric acid (UA), blood urea nitrogen (BUN), creatinine, cholesterol, total protein, and fibrinogen in three groups serum were studied: (1) Who had been permanent opium users more than 2 years (case). (2) Dependent person who has taken one month addiction withdrawal course (control). (3) A healthy group that had been demographically similar to the other groups. Findings According to these study findings, FBS serum level in the case group is lower than control group. Serum level of Na, creatinine, and blood triglyceride (TG) in case study are higher than group control. Concentration of potassium, Ca, UA, BUN, cholesterol, total serum protein, fibrinogen, and thrombin time in case study and group control showed no significant difference. Also, in withdrawing case serum level of Na, Ca, UA, BUN, creatinine, and TG significantly increase and thrombin time decrease. Conclusion According to this study not only the longtime use of opium but also opium with drawerin opium dependent people can change their serum biochemical factors. So recognition, treatment, and prevention of this change could be a new step in improving of health and condition of patients. PMID:25984281

  6. Creatinine Versus Cystatin C: Differing Estimates of Renal Function in Hospitalized Veterans Receiving Anticoagulants.

    Science.gov (United States)

    Wang, Christina Hao; Rubinsky, Anna D; Minichiello, Tracy; Shlipak, Michael G; Price, Erika Leemann

    2018-05-31

    Current practice in anticoagulation dosing relies on kidney function estimated by serum creatinine using the Cockcroft-Gault equation. However, creatinine can be unreliable in patients with low or high muscle mass. Cystatin C provides an alternative estimation of glomerular filtration rate (eGFR) that is independent of muscle. We compared cystatin C-based eGFR (eGFR cys ) with multiple creatinine-based estimates of kidney function in hospitalized patients receiving anticoagulants, to assess for discordant results that could impact medication dosing. Retrospective chart review of hospitalized patients over 1 year who received non-vitamin K antagonist anticoagulation, and who had same-day measurements of cystatin C and creatinine. Seventy-five inpatient veterans (median age 68) at the San Francisco VA Medical Center (SFVAMC). We compared the median difference between eGFR by the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) study equation using cystatin C (eGFR cys ) and eGFRs using three creatinine-based equations: CKD-EPI (eGFR EPI ), Modified Diet in Renal Disease (eGFR MDRD ), and Cockcroft-Gault (eGFR CG ). We categorized patients into standard KDIGO kidney stages and into drug-dosing categories based on each creatinine equation and calculated proportions of patients reclassified across these categories based on cystatin C. Cystatin C predicted overall lower eGFR compared to creatinine-based equations, with a median difference of - 7.1 (IQR - 17.2, 2.6) mL/min/1.73 m 2 versus eGFR EPI , - 21.2 (IQR - 43.7, - 8.1) mL/min/1.73 m 2 versus eGFR MDRD , and - 25.9 (IQR - 46.8, - 8.7) mL/min/1.73 m 2 versus eGFR CG . Thirty-one to 52% of patients were reclassified into lower drug-dosing categories using cystatin C compared to creatinine-based estimates. We found substantial discordance in eGFR comparing cystatin C with creatinine in this group of anticoagulated inpatients. Our sample size was limited and included few women. Further

  7. Special requirements for the fluid mechanical design of hard coal-fired SCR retrofit units

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    The system design of high-dust SCR units for retrofits is a challenge that is to be mastered in order to meet the fluid mechanical requirements. Retrofitting power plants with NOx control technologies is a cost-intensive adventure that many utilities are undertaking. Except for a few recent new boiler installations, SCR installations must be considered as retrofit projects. In most cases the limitation of space on site entails unfavorable conditions that do not allow appropriate upstream conditions for SCR catalysts. To comply with the requirements of high performance DeNOx systems and to lower the investment costs for retrofit units, several technical solutions and concepts for the reactor layout, for NOx and dust distribution, for flow stabilization in diffusers, and advanced ammonia injection systems are explained in this paper. Balcke-Duerr offers customer-tailored solutions for flow optimization, which are evaluated by model studies. Physical flow and dust model tests in an appropriate scale provide flexibility to test various engineering concepts. The experience of Balcke-Duerr is based on continuous research and development activities over the last 25 years and more than 350 executed projects for gas flow optimization applications. The success of these installations is a direct result of the key decisions based on the improved fluid mechanical design and proper system integration. This paper also identifies the sensible design particularities and solutions that have two be considered in the fluid mechanical design of high-dust SCR retrofit units. This article demonstrates that the layout of SCR units must be carefully reviewed in order to meet the performance requirements and to avoid problems, i.e. wear, catalyst plugging and ammonia slip. 9 refs., 18 figs.

  8. Did Creatinine Standardization Give Benefits to the Evaluation of Glomerular Filtration Rate?

    OpenAIRE

    Piéroni, Laurence; Bargnoux, Anne-Sophie; Cristol, Jean-Paul; Cavalier, Etienne; Delanaye, Pierre

    2017-01-01

    During the last decade, a lot of efforts has been made to improve the evaluation of renal functions. Measured Glomerular Filtration Rate (GFR) remains the only valuable test to confirm or confute the status of chronic kidney disease (CKD) and is recommended by Kidney Disease Global Outcomes guidelines when estimation of GFR is not reliable. However, in routine clinical practice, serum creatinine remains the one of the most prescribed biological parameters and is an undeniable factor, alone or...

  9. Automated monosegmented flow analyser. Determination of glucose, creatinine and urea.

    Science.gov (United States)

    Raimundo Júnior, I M; Pasquini, C

    1997-10-01

    An automated monosegmented flow analyser containing a sampling valve and a reagent addition module and employing a laboratory-made photodiode array spectrophotometer as detection system is described. The instrument was controlled by a 386SX IBM compatible microcomputer through an IC8255 parallel port that communicates with the interface which controls the sampling valve and reagent addition module. The spectrophotometer was controlled by the same microcomputer through an RS232 serial standard interface. The software for the instrument was written in QuickBasic 4.5. Opto-switches were employed to detect the air bubbles limiting the monosegment, allowing precise sample localisation for reagent addition and signal reading. The main characteristics of the analyser are low reagent consumption and high sensitivity which is independent of the sample volume. The instrument was designed to determine glucose, creatinine or urea in blood plasma and serum without hardware modification. The results were compared against those obtained by the Clinical Hospital of UNICAMP using commercial analysers. Correlation coefficients among the methods were 0.997, 0.982 and 0.996 for glucose, creatinine and urea, respectively.

  10. Rejuvenation of the SCR catalyst at Mehrum

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, Y.; Inatsume, Y.; Morita, I.; Kato, Y.; Yokoyama, K.; Ito, K. [Babcock Hitachi K.K., Kure-shi, Hiroshima-ken (Japan)

    2004-07-01

    Babcock Hitachi K.K. (BHK) received the contract of the rejuvenation of the SCR catalyst at the 750 MW coal-fired Mehrum Power Station (in Hohenhameln, Germany) in March 2003. The contractual coverage was 160 m{sup 3} of the entire catalyst layer. The catalyst, which had been in operation for 16 years since 1987, was originally supplied by BHK. The rejuvenation process developed for the Mehrum project consisted of two major steps: the first is to dust off the catalyst and remove the catalyst poison, and the second step is to add active material to enhance the catalyst activity. The catalyst must be dried after each washing. In order to minimize transportation cost and time, the rejuvenation work was done at the Mehrum station site. The scope of the rejuvenation work was shared between the owner and BHK. It took about one and a half months to complete the (total) on-site rejuvenation worked. The performance of the rejuvenated catalyst was superior to show the same level of activity as the unused catalyst and maintain the same SO{sub 2} conversion rate as the spent catalyst. This paper gives the details of the spent coal-fired SCR catalyst rejuvenation work. 13 figs., 1 tab.

  11. Paper-based Platform for Urinary Creatinine Detection.

    Science.gov (United States)

    Sittiwong, Jarinya; Unob, Fuangfa

    2016-01-01

    A new paper platform was developed for the colorimetric detection of creatinine. The filter paper was coated with 3-propylsulfonic acid trimethoxysilane and used as the platform. Creatinine in a cationic form was extracted onto the paper via an ion-exchange mechanism and detected through the Jaffé reaction, resulting in a yellow-orange color complex. The color change on the paper could be observed visually, and the quantitative detection of creatinine was achieved through monitoring the color intensity change. The color intensity of creatinine complexes on the paper platform as a function of the creatinine concentration provided a linear range for creatinine detection in the range of 10 - 60 mg L(-1) and a detection limit of 4.2 mg L(-1). The accuracy of the proposed paper-based method was comparable to the conventional standard Jaffé method. This paper platform could be applied for simple and rapid detection of creatinine in human urine samples with a low consumption of reagent.

  12. Accuracy of point-of-care serum creatinine devices for detecting patients at risk of contrast-induced nephropathy: a critical overview.

    Science.gov (United States)

    Martínez Lomakin, Felipe; Tobar, Catalina

    2014-12-01

    Contrast-induced nephropathy (CIN) is a common event in hospitals, with reported incidences ranging from 1 to 30%. Patients with underlying kidney disease have an increased risk of developing CIN. Point-of-care (POC) creatinine devices are handheld devices capable of providing quantitative data on a patient's kidney function that could be useful in stratifying preventive measures. This overview aims to synthesize the current evidence on diagnostic accuracy and clinical utility of POC creatinine devices in detecting patients at risk of CIN. Five databases were searched for diagnostic accuracy studies or clinical trials that evaluated the usefulness of POC devices in detecting patients at risk of CIN. Selected articles were critically appraised to assess their individual risk of bias by the use of standard criteria; 13 studies were found that addressed the diagnostic accuracy or clinical utility of POC creatinine devices. Most studies incurred a moderate to high risk of bias. Overall concordance between POC devices and reference standards (clinical laboratory procedures) was found to be moderate, with 95% limits of agreement often lying between -35.4 and +35.4 µmol/L (-0.4 and +0.4 mg/dL). Concordance was shown to decrease with worsening kidney function. Data on the clinical utility of these devices were limited, but a significant reduction in time to diagnosis was reported in two studies. Overall, POC creatinine devices showed a moderate concordance with standard clinical laboratory creatinine measurements. Several biases could have induced optimism in these estimations. Results obtained from these devices may be unreliable in cases of severe kidney failure. Randomized trials are needed to address the clinical utility of these devices.

  13. Reference intervals for serum cystatin C and creatinine of an ...

    African Journals Online (AJOL)

    2014-09-25

    Sep 25, 2014 ... Some studies suggest that GFR estimated from serum cystatin C (Cys C) is more accurate than ... Current clinical practice guidelines[1,2] recommend the use of ..... Source of Support: Nil, Conflict of Interest: None declared.

  14. Analysis and study on the performance variation of SCR DeNOx catalyst of Coal-Fired Boilers

    International Nuclear Information System (INIS)

    Jianxing, Ren; Fangqin, Li; Jiang, Wu; Qingrong, Liu; Yongwen, Yang; Zhongzhu, Qiu

    2010-01-01

    Nitrogen oxides (NO x ) are one kind of harmful substances from the burning process of fossil fuel and air at high temperature. NO x emissions cause serious pollution on atmospheric environment. In this paper, coal-fired utility boilers were chosen as the object, NO x formation mechanism and control were studied, and SCR deNO x technology was used to control NO x emissions from coal-fired boilers. Analyzed the relationship between deNO x efficiency and characteristics of SCR DeNO x catalyst. Through analysis, affecting SCR DeNO x catalyst failure factors, change law of catalytic properties and technical measures to extend the service life of the catalyst were gotten. (author)

  15. Synthesis, Characterization and Biological Activities of Creatinine Amides and Creatinine Schiff Bases.

    Science.gov (United States)

    Mumtaz, Amara; Zahoor, Fareeha; Zaib, Sumera; Nawaz, Muhammad Azhar H; Saeed, Aamer; Waseem, Amir; Khan, Afsar; Hussain, Izhar; Iqbal, Jamshed

    2017-01-30

    In spite of substantial progress in scientific cognizance and medical technology, still infectious diseases are among the leading cause of morbidity and mortality. Creatinine and Schiff bases are well known for their diverse range of biological activities and thought to be emerging and useful therapeutic target for the treatment of several diseases. The present work was aimed to illustrate the influence of substitution of amides and Schiff bases on creatinine and their antimicrobial, antioxidant and anti-urease effectiveness was determined. Creatinine substituted amides (1-2) and creatinine Schiff bases (3-7) were synthesized and characterized by NMR and IR spectral data in combination with elemental analysis. All the compounds (1-7) were investigated on Jack bean urease for their urease inhibitory potential. Investigation of antimicrobial activity of the compounds was made by the agar dilution method. Moreover, 1,1-diphenyl-2- picrylhydrazyl (DPPH) method was used to determine their antioxidant potential. Molecular docking studies were also carried out to elucidate their relationship with the binding pockets of the enzyme. The compounds were found to be potent inhibitors of urease. The synthesized derivatives exhibited significant inhibition against Gram-positive and Gram-negative bacterial strains, as compared to standard, ciprofloxacin. Creatinine based derivatives exhibited potential antifungal activity when tested on infectious and pathogenic fungal strains. Similarly, most of the compounds exhibited good antioxidant activity. These derivatives may serve as a source of potential antioxidants and also help to retard microbial growth in food industry. Similarly, the studies provide a basis for further research to develop more potent urease inhibitory compounds of medicinal /agricultural interest. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. Radio-Frequency-Controlled Urea Dosing for NH₃-SCR Catalysts: NH₃ Storage Influence to Catalyst Performance under Transient Conditions.

    Science.gov (United States)

    Dietrich, Markus; Hagen, Gunter; Reitmeier, Willibald; Burger, Katharina; Hien, Markus; Grass, Philippe; Kubinski, David; Visser, Jaco; Moos, Ralf

    2017-11-28

    Current developments in exhaust gas aftertreatment led to a huge mistrust in diesel driven passenger cars due to their NO x emissions being too high. The selective catalytic reduction (SCR) with ammonia (NH₃) as reducing agent is the only approach today with the capability to meet upcoming emission limits. Therefore, the radio-frequency-based (RF) catalyst state determination to monitor the NH₃ loading on SCR catalysts has a huge potential in emission reduction. Recent work on this topic proved the basic capability of this technique under realistic conditions on an engine test bench. In these studies, an RF system calibration for the serial type SCR catalyst Cu-SSZ-13 was developed and different approaches for a temperature dependent NH₃ storage were determined. This paper continues this work and uses a fully calibrated RF-SCR system under transient conditions to compare different directly measured and controlled NH₃ storage levels, and NH₃ target curves. It could be clearly demonstrated that the right NH₃ target curve, together with a direct control on the desired level by the RF system, is able to operate the SCR system with the maximum possible NO x conversion efficiency and without NH₃ slip.

  17. Validity of Serum Cystatin C as an Early and Accurate Marker of Glomerular Filtration Rate in type 1 Diabetes Mellitus Patients

    International Nuclear Information System (INIS)

    Fathy, H.A.; Fathy, M.A.

    2017-01-01

    The present study aims at exploring the clinical validity of measuring cystatin C for the early and accurate assessment of GFR (as compared to measuring serum creatinine or β2 microglobulin) in patients suffering from type 1 diabetes mellitus who are at risk of developing diabetic nephropathy as well as those who have already developed the condition. This study included 80 subjects who were further subdivided into two groups: Control group (1) which comprised 20 healthy age and sex matched children. Patient group (2) comprised 60 patients of both sexes properly diagnosed with type 1 diabetes. The patients were further subdivided into 3 subgroups according albumin levels in their 24 hour urine : Group 2a: 20 patients who were considered normo-albumin uric. Group 2b: 20 patients who were considered micro-albumin uric. Group 2c: 20 patients who were considered macro - albumin uric. All subjects were subjected to the estimation of serum creatinine level as well as serum β2 microglobulin and serum cystatin C levels. They were also subjected to Isotope renogram using "9"9"mTc- diethylene triamine pentaacetic acid (DTPA) single injection technique for accurate measurement of glomerular filtration rate (GFR). A positive correlation was observed between each of serum creatinine, β2 microglobulin, cystatin C with albumin in 24 hr urine in all the patient subgroups and this correlation was highly significant. However, the correlation between serum cystatin C levels in the diabetic patients and albumin in 24 hr urine was higher than that observed for either serum creatinine or serum β2 microglobulin. Cystatin C had the highest negative correlation with GFR (as measured by "9"9"mTc-DTPA clearance) compared to either serum creatinine or serum β 2 microglobulin in group II patients. It can be concluded that cystatin C could act as an early and accurate marker of GFR and renal function in patients with type 1 diabetes mellitus at risk of developing or who have already

  18. Chemiluminescence of creatinine/H2O2/Co(2+) and its application for selective creatinine detection.

    Science.gov (United States)

    Hanif, Saima; John, Peter; Gao, Wenyue; Saqib, Muhammad; Qi, Liming; Xu, Guobao

    2016-01-15

    Creatinine is an important biomarker in clinical diagnosis and biomonitoring programs as well as urinary metabolomic/metabonomics research. Current methods are either nonselective, time consuming or require heavy and expensive instruments. In this study, chemiluminescence of creatinine with hydrogen peroxide has been reported for the first time, and its chemiluminescence is remarkably enhanced in the presence of cobalt ions. By utilizing these phenomena, we have developed a sensitive and selective chemiluminescence method for creatinine determination by coupling with flow injection analysis. The calibration curve is linear in the range of 1×10(-7)-3×10(-5)mol/L with a limit of detection (S/N=3) of 7.2×10(-8)mol/L, which is adequate for detecting creatinine in the clinically accepted range. The relative standard deviation for seven measurements of 3×10(-5)mol/L creatinine is 1.2%. The chemiluminescence method was then utilized to detect creatinine in human urine samples after simple dilution with water. It takes less than 1min each measurement and the recoveries for spiked urine samples were 100-103%. The interference study demonstrates that some common species in urine, such as amino acids, ascorbic acid and creatine, have negligible effects on creatinine detection. The present method does not use expensive instruments, enzymes and separation technique. This method has the advantages of sensitivity, selectivity, simplicity, rapidity, and low cost. It holds great promise for basic or comprehensive metabolic panel, drug screening, anti-dopping, and urinary metabolomic/metabonomics research. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Process identification of the SCR system of coal-fired power plant for de-NOx based on historical operation data.

    Science.gov (United States)

    Li, Jian; Shi, Raoqiao; Xu, Chuanlong; Wang, Shimin

    2018-05-08

    The selective catalytic reduction (SCR) system, as one principal flue gas treatment method employed for the NO x emission control of the coal-fired power plant, is nonlinear and time-varying with great inertia and large time delay. It is difficult for the present SCR control system to achieve satisfactory performance with the traditional feedback and feedforward control strategies. Although some improved control strategies, such as the Smith predictor control and the model predictive control, have been proposed for this issue, a well-matched identification model is essentially required to realize a superior control of the SCR system. Industrial field experiment is an alternative way to identify the SCR system model in the coal-fired power plant. But it undesirably disturbs the operation system and is costly in time and manpower. In this paper, a process identification model of the SCR system is proposed and developed by applying the asymptotic method to the sufficiently excited data, selected from the original historical operation database of a 350 MW coal-fired power plant according to the condition number of the Fisher information matrix. Numerical simulations are carried out based on the practical historical operation data to evaluate the performance of the proposed model. Results show that the proposed model can efficiently achieve the process identification of the SCR system.

  20. Creatinine Deiminase Adsorption onto Silicalite-Modified pH-FET for Creation of New Creatinine-Sensitive Biosensor

    OpenAIRE

    Marchenko, Svitlana V.; Soldatkin, Oleksandr O.; Kasap, Berna Ozansoy; Kurc, Burcu Akata; Soldatkin, Alexei P.; Dzyadevych, Sergei V.

    2016-01-01

    In the work, silicalite particles were used for the surface modification of pH-sensitive field-effect transistors (pH-FETs) with the purpose of developing new creatinine-sensitive biosensor. Creatinine deiminase (CD) adsorbed on the surface of silicalite-coated pH-FET served as a bioselective membrane. The biosensor based on CD immobilized in glutaraldehyde vapor (GA) was taken as control. The creatinine-sensitive biosensor obtained by adsorption on silicalite was shown to have better analyti...

  1. Creatinine metabolism in Cryptococcus neoformans and Cryptococcus bacillisporus.

    OpenAIRE

    Polacheck, I; Kwon-Chung, K J

    1980-01-01

    The pathogenic species of Cryptococcus, C. neoformans and C. bacillisporus, utilized creatinine as a source of nitrogen but not of carbon. Chromatographic and autoradiographic studies suggest that creatinine metabolism in both species involves a single step resulting in the production of methylhydantoin and ammonia. The enzyme responsible for this step, creatinine deiminase, was produced by the cells only in the presence of creatinine in both species. The synthesis of creatinine deiminase was...

  2. L-Cysteine inhibits root elongation through auxin/PLETHORA and SCR/SHR pathway in Arabidopsis thaliana.

    Science.gov (United States)

    Wang, Zhen; Mao, Jie-Li; Zhao, Ying-Jun; Li, Chuan-You; Xiang, Cheng-Bin

    2015-02-01

    L-Cysteine plays a prominent role in sulfur metabolism of plants. However, its role in root development is largely unknown. Here, we report that L-cysteine reduces primary root growth in a dosage-dependent manner. Elevating cellular L-cysteine level by exposing Arabidopsis thaliana seedlings to high L-cysteine, buthionine sulphoximine, or O-acetylserine leads to altered auxin maximum in root tips, the expression of quiescent center cell marker as well as the decrease of the auxin carriers PIN1, PIN2, PIN3, and PIN7 of primary roots. We also show that high L-cysteine significantly reduces the protein level of two sets of stem cell specific transcription factors PLETHORA1/2 and SCR/SHR. However, L-cysteine does not downregulate the transcript level of PINs, PLTs, or SCR/SHR, suggesting that an uncharacterized post-transcriptional mechanism may regulate the accumulation of PIN, PLT, and SCR/SHR proteins and auxin transport in the root tips. These results suggest that endogenous L-cysteine level acts to maintain root stem cell niche by regulating basal- and auxin-induced expression of PLT1/2 and SCR/SHR. L-Cysteine may serve as a link between sulfate assimilation and auxin in regulating root growth. © 2014 Institute of Botany, Chinese Academy of Sciences.

  3. Relation between creatinine and uric acid excretion.

    OpenAIRE

    Nishida, Y

    1992-01-01

    The relation between creatinine and uric acid metabolism was analysed in 77 male patients with primary gout and 62 healthy male subjects. Significant positive correlations between 24 hour urinary creatinine and uric acid excretion were shown in both groups. The mean urinary creatinine and uric acid excretions in the patients with gout were significantly increased as compared with those of normal male controls. These results suggest that there is a close correlation between creatinine and uric...

  4. The relationship of nitric oxide synthesis capacity, oxidative stress, and albumin-to-creatinine ratio in black and white men: the SABPA study.

    Science.gov (United States)

    Mels, Catharina M C; Huisman, Hugo W; Smith, Wayne; Schutte, Rudolph; Schwedhelm, Edzard; Atzler, Dorothee; Böger, Rainer H; Ware, Lisa J; Schutte, Aletta E

    2016-02-01

    Inadequate substrate availability and increased nitric oxide synthase inhibitor levels attenuate nitric oxide (NO) synthesis, whereas increased vascular oxidative stress may lead to inactivation of NO. We compared markers of NO synthesis capacity and oxidative stress in a bi-ethnic male population. Inter-relationships of ambulatory blood pressure and urinary albumin-to-creatinine ratio with NO synthesis capacity and oxidative stress markers were investigated. NO synthesis capacity markers (L-arginine, asymmetric dimethylarginine (ADMA), and symmetric dimethylarginine (SDMA)) and oxidative stress markers (serum peroxides, total glutathione, glutathione peroxidase (GPx), glutathione reductase (GR), superoxide dismutase (SOD), and catalase) were measured. Black men displayed higher blood pressure and albumin-to-creatinine ratio (all p creatinine ratio. In white men, albumin-to-creatinine ratio was positively associated with ADMA (R (2) = 0.18; β = 0.39; p creatinine ratio displayed a favorable NO synthesis capacity. This may be counteracted by increased inactivation of NO, although it was not linked to vascular or renal phenotypes. In white men, reduced NO synthesis capacity may lower NO bio-availability, thereby influencing the albumin-to-creatinine ratio.

  5. A New Risk Factor Profile for Contrast-Induced Acute Kidney Injury in Patients Who Underwent an Emergency Percutaneous Coronary Intervention.

    Science.gov (United States)

    Yuan, Ying; Qiu, Hong; Song, Lei; Hu, Xiaoying; Luo, Tong; Zhao, Xueyan; Zhang, Jun; Wu, Yuan; Qiao, Shubin; Yang, Yuejin; Gao, Runlin

    2018-07-01

    We developed a new risk factor profile for contrast-induced acute kidney injury (CI-AKI) under a new definition in patients who underwent an emergency percutaneous coronary intervention (PCI). Consecutive patients (n = 1061) who underwent an emergency PCI were divided into a derivation group (n = 761) and a validation group (n = 300). The rates of CI-AKI were 23.5% (definition 1: serum creatinine [SCr] increase ≥25% in 72 hours), 4.3% (definition 2: SCr increase ≥44.2 μmol/L in 72 hours), and 7.0% (definition 3: SCr increase ≥44.2 μmol/L in 7 days). Due to the high sensitivity of definition 1 and the high rate of missed cases for late diagnosis of CI-AKI under definition 2, definition 3 was used in the study. The risk factor profile included body surface area 15.00 × 10 9 /L ( P = .047), estimated glomerular filtration rate 133 μmol/L ( P = .007), intra-aortic balloon pump application ( P = .006), and diuretics administration ( P risk factor profile of CI-AKI under a new CI-AKI definition in emergency PCI patients is easily applicable with a useful predictive value.

  6. GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assays.

    Science.gov (United States)

    Tsikas, Dimitrios; Wolf, Alexander; Mitschke, Anja; Gutzki, Frank-Mathias; Will, Wolfgang; Bader, Michael

    2010-10-01

    In consideration of its relatively constant urinary excretion rate, creatinine in urine is a useful biochemical parameter to correct the urinary excretion rate of endogenous and exogenous biomolecules. Assays based on the reaction of creatinine and picric acid first reported by Jaffé in 1886 still belong to the most frequently used laboratory approaches for creatinine measurement in urine. Further analytical methods for creatinine include HPLC-UV, GC-MS, and LC-MS and LC-MS/MS approaches. In the present article we report on the development, validation and biomedical application of a new GC-MS method for the reliable quantitative determination of creatinine in human urine, plasma and serum. This method is based on the derivatization of creatinine (d(0)-Crea) and the internal standard [methyl-trideutero]creatinine (d(3)-Crea) with pentafluorobenzyl (PFB) bromide in the biological sample directly or after dilution with phosphate buffered saline, extraction of the reaction products with toluene and quantification in 1-μl aliquots of the toluene extract by selected-ion monitoring of m/z 112 for d(0)-Crea-PFB and m/z 115 for d(3)-Crea-PFB in the electron-capture negative-ion chemical ionization mode. The limit of detection of the method is 100 amol of creatinine. In an inter-laboratory study on urine samples from 100 healthy subjects, the GC-MS method was used to test the reliability of currently used Jaffé, enzymatic and HPLC assays in clinical and occupational studies. The results of the inter-laboratory study indicate that all three tested methods allow for satisfactory quantification of creatinine in human urine. The GC-MS method is suitable for use as a reference method for urinary creatinine in humans. In serum, creatine was found to contribute to creatinine up to 20% when measured by the present GC-MS method. The application of the GC-MS method can be extended to other biological samples such as saliva. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  8. Serum leptin level and its significance in chronic renal failure hemodialysis patients

    International Nuclear Information System (INIS)

    Zhang Yong; You Yuping; Chen Weizhen; Mo Congjian

    2003-01-01

    To study serum leptin level in chronic renal failure (CRF) hemodialysis patients and the relationship between serum leptin level and residue renal function, body composition, and indices of malnutrition, 31 end-stage CRF hemodialysis patients and 38 healthy people were enrolled. Serum leptin levels were detected by radioimmunoassay. BMI, %Fat and LBM were measured by bioelectrical impedance analysis device. Alb, Chol, Hgb, BUN, SCr and Ccr of the patients were also examined. Results showed that Serum leptin level in end-stage CRF hemodialysis patients was markedly higher than that in healthy controls (P 0.05). Conclusion: Hyperleptinemia existed in end-stage CRF hemodialysis patients and might cause the loss of LBM. The leptin level was not correlated with residue renal function, but it could reflect the fat content. However, serum leptin did not play a significant role in protein malnutrition in end-stage CRF hemodialysis patients

  9. Pemberian diet ekstra formula komersial dan diet ekstra filtrat ikan gabus intradialisis serta pengaruhnya terhadap kadar serum albumin dan kreatinin pasien dengan hemodialisis di RSU Dr. Saiful Anwar Malang

    Directory of Open Access Journals (Sweden)

    Etik Sulistyowati

    2008-11-01

    Conclusion: There was significant effect of the supply of commercial formula and local catfish filtrate extra diet to increase of albumin serum level of the subject and there was no significant effect of the supply of extra diet to creatinine serum level; however, the supply of local catfish filtrate extra diet could maintain creatinine serum level.

  10. SCR series switch and impulse crowbar at the Lawrence Berkeley Laboratory for CTR neutral beam source development

    International Nuclear Information System (INIS)

    Franck, J.V.; Arthur, A.A.; Brusse, L.A.; Low, W.

    1977-10-01

    The series switch is designed to operate at 120kV and pass 65A for 0.5 sec every 30 sec on the Lawrence Berkeley Laboratory CTR Neutral Beam Source Test Stand IIIB. The series switch consists of 400 individual SCR circuits connected in series and is turned on by a simple system of cascaded pulse transformers with multiple single turn secondaries each driving the individual SCR gates. It is turned off by an SCR impulse crowbar that momentarily shorts the power supply allowing the series switch to recover. The SCR switch has been tested in the impulse crowbar configuration and will reliably commutate up to 90A at 120kV. The series switch and impulse crowbar are now in service in Test Stand IIIB. A series switch and impulse crowbar similar in concept is routinely powering a 10 x 10 cm source at 150kV, 20A, 0.5 sec with a 1% duty cycle on the Lawrence Berkeley Laboratory CTR NSB Test Stand IIIA

  11. In situ DRIFTS investigation of NH3-SCR reaction over CeO2/zirconium phosphate catalyst

    Science.gov (United States)

    Zhang, Qiulin; Fan, Jie; Ning, Ping; Song, Zhongxian; Liu, Xin; Wang, Lanying; Wang, Jing; Wang, Huimin; Long, Kaixian

    2018-03-01

    A series of ceria modified zirconium phosphate catalysts were synthesized for selective catalytic reduction of NO with ammonia (NH3-SCR). Over 98% NOx conversion and 98% N2 selectivity were obtained by the CeO2/ZrP catalyst with 20 wt.% CeO2 loading at 250-425 °C. The interaction between CeO2 and zirconium phosphate enhanced the redox abilities and surface acidities of the catalysts, resulting in the improvement of NH3-SCR activity. The in situ DRIFTS results indicated that the NH3-SCR reaction over the catalysts followed both Eley-Rideal and Langmuir-Hinshelwood mechanisms. The amide (sbnd NH2) groups and the NH4+ bonded to Brønsted acid sites were the important intermediates of Eley-Rideal mechanism.

  12. Vanadia supported on zeolites for SCR of NO by ammonia

    DEFF Research Database (Denmark)

    Putluru, Siva Sankar Reddy; Riisager, Anders; Fehrmann, Rasmus

    2010-01-01

    , acidity and micropore structure of the support. Apparently the support hosted the potassium oxide on the acid sites, thereby protecting the active vanadium species from poisoning. Zeolite based catalysts might therefore prove useful for SCR of NO in alkali-containing flue gases from, e.g. biomass fired...

  13. Deactivation of vanadia-based commercial SCR catalysts by polyphosphoric acids

    DEFF Research Database (Denmark)

    Castellino, Francesco; Rasmussen, Søren Birk; Jensen, Anker Degn

    2008-01-01

    Commercial vanadia-based SCR monoliths have been exposed to flue gases in a pilot-scale Setup into which phosphoric acid has been added and the deactivation has been followed during the exposure time. Separate measurements by SMPS showed that the phosphoric acid formed polyphosphoric acid aerosols...

  14. Acute kidney injury in liver cirrhosis: new definition and application

    Directory of Open Access Journals (Sweden)

    Florence Wong

    2016-12-01

    Full Text Available The traditional diagnostic criteria of renal dysfunction in cirrhosis are a 50% increase in serum creatinine (SCr with a final value above 1.5 mg/dL. This means that patients with milder degrees of renal dysfunction are not being diagnosed, and therefore not offered timely treatment. The International Ascites Club in 2015 adapted the term acute kidney injury (AKI to represent acute renal dysfunction in cirrhosis, and defined it by an increase in SCr of 0.3 mg/dL (26.4 µmoL/L in <48 hours, or a 50% increase in SCr from a baseline within ≤3 months. The severity of AKI is described by stages, with stage 1 represented by these minimal changes, while stages 2 and 3 AKI by 2-fold and 3-fold increases in SCr respectively. Hepatorenal syndrome (HRS, renamed AKI-HRS, is defined by stage 2 or 3 AKI that fulfils all other diagnostic criteria of HRS. Various studies in the past few years have indicated that these new diagnostic criteria are valid in the prediction of prognosis for patients with cirrhosis and AKI. The future in AKI diagnosis may include further refinements such as inclusion of biomarkers that can identify susceptibility for AKI, differentiating the various prototypes of AKI, or track its progression.

  15. Creatinine Clearance Is Not Equal to Glomerular Filtration Rate and Cockcroft-Gault Equation Is Not Equal to CKD-EPI Collaboration Equation.

    Science.gov (United States)

    Fernandez-Prado, Raul; Castillo-Rodriguez, Esmeralda; Velez-Arribas, Fernando Javier; Gracia-Iguacel, Carolina; Ortiz, Alberto

    2016-12-01

    Direct oral anticoagulants (DOACs) may require dose reduction or avoidance when glomerular filtration rate is low. However, glomerular filtration rate is not usually measured in routine clinical practice. Rather, equations that incorporate different variables use serum creatinine to estimate either creatinine clearance in mL/min or glomerular filtration rate in mL/min/1.73 m 2 . The Cockcroft-Gault equation estimates creatinine clearance and incorporates weight into the equation. By contrast, the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations estimate glomerular filtration rate and incorporate ethnicity but not weight. As a result, an individual patient may have very different renal function estimates, depending on the equation used. We now highlight these differences and discuss the impact on routine clinical care for anticoagulation to prevent embolization in atrial fibrillation. Pivotal DOAC clinical trials used creatinine clearance as a criterion for patient enrollment, and dose adjustment and Federal Drug Administration recommendations are based on creatinine clearance. However, clinical biochemistry laboratories provide CKD-EPI glomerular filtration rate estimations, resulting in discrepancies between clinical trial and routine use of the drugs. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Serum Creatinine Distinguishes Duchenne Muscular Dystrophy from Becker Muscular Dystrophy in Patients Aged ≤3 Years: A Retrospective Study.

    Science.gov (United States)

    Wang, Liang; Chen, Menglong; He, Ruojie; Sun, Yiming; Yang, Juan; Xiao, Lulu; Cao, Jiqing; Zhang, Huili; Zhang, Cheng

    2017-01-01

    Here, we investigated correlations between serum creatinine (SCRN) levels and clinical phenotypes of dystrophinopathy in young patients. Sixty-eight patients with dystrophinopathy at the Neuromuscular Clinic, The First Affiliated Hospital, Sun Yat-sen University, were selected for this study. The diagnosis of dystrophinopathy was based on clinical manifestation, biochemical changes, and molecular analysis. Some patients underwent muscle biopsies; SCRN levels were tested when patients were ≤3 years old, and reading frame changes were analyzed. Each patient was followed up, and motor function and clinical phenotype were assessed when the same patients were ≥4 years old. Our findings indicated that in young patients, lower SCRN levels were associated with increased disease severity ( p  Becker muscular dystrophy (BMD) ( p  dystrophy (DMD) ( p  < 0.01) and were significantly higher in patients carrying in-frame mutations than in patients carrying out-of-frame mutations ( p  < 0.001). SCRN level cutoff values for identifying mild BMD [18 µmol/L; area under the curve (AUC): 0.947; p  < 0.001] and DMD (17 µmol/L; AUC: 0.837; p  < 0.001) were established. These results suggest that SCRN might be a valuable biomarker for distinguishing DMD from BMD in patients aged ≤3 years and could assist in the selection of appropriate treatment strategies.

  17. Significance of Serum Leptin Assessment in Chronic Renal Patients on Dialysis

    International Nuclear Information System (INIS)

    Salem, E.S; Tawfik, M.S; ELaseily, E.S.

    2013-01-01

    The number of patients suffering from renal failure indicating dialysis has been increasing worldwide. Leptin hormone plays an important role in the development of malnutrition in these patients. Bone produces different hormones, such as osteocalcin (OC), which influences energy expenditure in humans. Disturbances in mineral metabolism and bone disease are common complications of chronic kidney disease (CKD). There are increasing evidences suggesting that these disorders in mineral and bone metabolism are associated with increased risk of cardiovascular calcification, morbidity, and mortality, especially among those who undergo maintenance renal dialysis. The present study was carried out to evaluate the importance of serum leptin assessment in renal dialysis patients. Serum leptin level was estimated by radioimmunoassay (RIA) using recombinant human leptin (Leptin- Human Ria-CT). Immunoradiometric assay kit (host IRMA) was used for in-vitro quantitative measurement of human intact OC. Serum creatinine level was determined by colorimetric method. This study included 60 patients (twenty suffering from CKD, thirty on dialysis and ten healthy controls). Serum leptin, OC and creatinine were found to be higher in patients of both groups compared to that of controls. Maximum increase was observed in patients on dialysis. From these results it is possible to conclude that, although patients with chronic renal disease exhibited significant increase in serum leptin, yet sudden additional increase can be related to serious pathology that can end in renal failure. The present study also highlighted the importance of OC as a marker of disturbed mineral-bone metabolism in chronic kidney disease (CKD) patients and those receiving dialysis that could lead to the atherosclerosis, extravascular calcification, morbidity and mortality. KeywoRdSLeptin, osteocalcin, Radioimmunoassay (RIA), Chronic kidney disease, Renal dialysis, Creatinine.

  18. Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay.

    Science.gov (United States)

    Kemperman, F A; Silberbusch, J; Slaats, E H; van Zanten, A P; Weber, J A; Krediet, R T; Arisz, L

    1999-05-01

    Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this study was to compare cimetidine-aided GFR estimations using various creatinine assays. In 30 outpatients with NIDDM GFR was measured as the urinary clearance of continuously infused [125I]iothalamate. Plasma creatinine concentration was analysed after oral cimetidine with an alkaline picrate (AP) method, with an enzymatic (PAP) assay and with HPLC. GFR estimations were calculated with the Cockcroft Gault formula (CG). AP creatinine concentrations were significantly higher than PAP or HPLC values. GFR estimations by AP (CG(AP) 66 +/- 19 ml/min/1.73 m2, mean SD) were significantly lower than GFR (89 +/- 30), whereas CG(PAP) (85 +/- 30) and CG(HPLC) (84 +/- 34 ml/min/1.73 m2) were not. Bland and Altman analysis showed a difference between CG(AP) and GFR of -22.4 +/- 17.7 ml/min/1.73 m2; this difference becomes larger when the GFR increases. The difference between CG and GFR was only -3.8 +/- 14.8 ml/min/1.73 m2 for PAP and -4.4 +/- 17.5 ml/min/1.73 m2 for HPLC, without any systematic difference. A good assessment of the GFR from plasma creatinine after cimetidine administration is possible when creatinine is measured with an enzymatic assay or with the less convenient HPLC method. The more widespread and cheaper alkaline picrate assay is not suitable for GFR-estimation.

  19. The soluble receptor for vitamin B12 uptake (sCD320) increases during pregnancy and occurs in higher concentration in urine than in serum

    DEFF Research Database (Denmark)

    Abuyaman, Omar; Andreasen, Birgitte H; Kronborg, Camilla

    2013-01-01

    BACKGROUND: Cellular uptake of vitamin B12 (B12) demands binding of the vitamin to transcobalamin (TC) and recognition of TC-B12 (holoTC) by the receptor CD320, a receptor expressed in high quantities on human placenta. We have identified a soluble form of CD320 (sCD320) in serum and here we...... gestational weeks 17-41. sCD320, holoTC, total TC and complex formation between holoTC and sCD320 were measured by in-house ELISA methods, while creatinine was measured on the automatic platform Cobas 6000. Size exclusion chromatography was performed on a Superdex 200 column. RESULTS: Median (range) of serum...... was around two fold higher than in serum. Urinary sCD320/creatinine ratio correlated with serum sCD320 and reached a peak median level of 53 (30-101) pmol/mmol creatinine (week 35). sCD320 present in serum and urine showed the same elution pattern upon size exclusion chromatography. CONCLUSION: We report...

  20. Preliminary Studies on Some Haematological and Serum ...

    African Journals Online (AJOL)

    The mean serum values of sodium, potassium, chloride and bicarbonate, as well as urea, creatinine and alanine aminotransferase(ALT) enzyme did not differ from the normal values, while the mean aspartate aminotransferase (AST) enzyme value appeared to be lower than the normal range.In conclusion, the RBC, PCV ...

  1. Estimating Renal Function in the Elderly Malaysian Patients Attending Medical Outpatient Clinic: A Comparison between Creatinine Based and Cystatin-C Based Equations.

    Science.gov (United States)

    Jalalonmuhali, Maisarah; Elagel, Salma Mohamed Abouzriba; Tan, Maw Pin; Lim, Soo Kun; Ng, Kok Peng

    2018-01-01

    To assess the performance of different GFR estimating equations, test the diagnostic value of serum cystatin-C, and compare the applicability of cystatin-C based equation with serum creatinine based equation for estimating GFR (eGFR) in comparison with measured GFR in the elderly Malaysian patients. A cross-sectional study recruiting volunteered patients 65 years and older attending medical outpatient clinic. 51 chromium EDTA ( 51 Cr-EDTA) was used as measured GFR. The predictive capabilities of Cockcroft-Gault equation corrected for body surface area (CGBSA), four-variable Modification of Diet in Renal Disease (4-MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations using serum creatinine (CKD-EPIcr) as well as serum cystatin-C (CKD-EPIcys) were calculated. A total of 40 patients, 77.5% male, with mean measured GFR 41.2 ± 18.9 ml/min/1.73 m 2 were enrolled. Mean bias was the smallest for 4-MDRD; meanwhile, CKD-EPIcr had the highest precision and accuracy with lower limit of agreement among other equations. CKD-EPIcys equation did not show any improvement in GFR estimation in comparison to CKD-EPIcr and MDRD. The CKD-EPIcr formula appears to be more accurate and correlates better with measured GFR in this cohort of elderly patients.

  2. Influence of Urine Creatinine on the Relationship between the Albumin-to-Creatinine Ratio and Cardiovascular Events

    Science.gov (United States)

    Carter, Caitlin E.; Gansevoort, Ronald T.; Scheven, Lieneke; Heerspink, Hiddo J. Lambers; Shlipak, Michael G.; de Jong, Paul E.

    2012-01-01

    Summary Background and objectives In the albumin-to-creatinine ratio (spot-ACR), urine creatinine corrects for tonicity but also reflects muscle mass. Low muscle mass is associated with cardiovascular disease (CVD). We hypothesized that the spot-ACR would be higher in women, lower-weight persons, and older individuals, independent of timed urine albumin excretion (24hr-UAE), and accordingly, that spot-ACR would be more strongly associated with CVD events than 24hr-UAE in these subgroups. Design, setting, participants, & methods 2627 PREVEND (Prevention of Renal and Vascular End-stage Disease) participants with 24hr-UAE creatinine concentration (HR, 1.16 per ln-SD higher) were associated with CVD events. Spot-ACR was more strongly associated with CVD events than either component of the ratio (HR, 1.41 per ln-SD higher). Associations of spot-ACR ≥10 mg/g versus less (HR, 2.33) and 24hr-UAE ≥10 mg/d versus less (HR, 2.09) with CVD events were similar, and there were no significant differences across subgroups (P for interactions >0.06). Conclusions In community-living individuals with 24hr-UAE creatinine is associated with CVD risk, but high urine albumin is a stronger determinant of the association of spot-ACR with CVD than is low urine creatinine. PMID:22383750

  3. Importance of oral fluid intake after coronary computed tomography angiography: An observational study

    International Nuclear Information System (INIS)

    Yoshikawa, Daiji; Isobe, Satoshi; Sato, Kimihide; Ohashi, Toshio; Fujiwara, Yuka; Ohyama, Hisato; Ishii, Hideki; Murohara, Toyoaki

    2011-01-01

    Background: The prevention of contrast-induced acute kidney injury (AKI) after coronary computed tomography angiography (CCTA) is important because patients referred for CCTA often need further contrast exposure such as an invasive coronary angiography. We aimed to examine the effects of oral volume intake on renal function in patients with preserved renal function referred for CCTA. Methods: We enrolled 180 patients who were referred for CCTA. The serum creatinine (SCr) and estimated glomerular filtration rate (eGFR) levels were measured before, 24 h, and a mean of 4.8 days after CCTA. The amount of unrestricted oral fluid intake for 24 h was checked. The patients were divided into two groups: 106 subjects with a rise in SCr after CCTA (group A); and 74 without (group B). Results: Significant correlations were observed between the amount of oral fluid intake and the percentage changes in SCr (%SCr) (r = -0.66, p < 0.0001) as well as the absolute changes in eGFR (ΔeGFR) (r = 0.65, p < 0.0001). The percentage of patients showing hemoglobin-A1c (HbA1c) ≥ 6.5% was greater in group A than in group B (29% vs. 18%, p < 0.001). Patients with HbA1c ≥ 6.5% showed higher %SCr and lower ΔeGFR compared to those without it. Multiple regression analysis revealed that the amount of oral fluid intake was the only independent predictor for a rise in SCr (β = -0.731, p < 0.0001). Conclusion: Oral volume intake after CCTA is a very simple but important prophylactic procedure for contrast-induced AKI especially in diabetic patients.

  4. Importance of oral fluid intake after coronary computed tomography angiography: An observational study

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Daiji [Department of Cardiology, Nagoya University Graduate School of Medicine (Japan); Department of Cardiology, Kami-iida Daiichi General Hospital, Nagoya (Japan); Isobe, Satoshi, E-mail: sisobe@med.nagoya-u.ac.jp [Department of Cardiology, Nagoya University Graduate School of Medicine (Japan); Department of Cardiology, Kami-iida Daiichi General Hospital, Nagoya (Japan); Sato, Kimihide; Ohashi, Toshio [Division of Radiology, Kami-iida Daiichi General Hospital, Nagoya (Japan); Fujiwara, Yuka; Ohyama, Hisato [Division of Nursing, Kami-iida Daiichi General Hospital, Nagoya (Japan); Ishii, Hideki; Murohara, Toyoaki [Department of Cardiology, Nagoya University Graduate School of Medicine (Japan)

    2011-01-15

    Background: The prevention of contrast-induced acute kidney injury (AKI) after coronary computed tomography angiography (CCTA) is important because patients referred for CCTA often need further contrast exposure such as an invasive coronary angiography. We aimed to examine the effects of oral volume intake on renal function in patients with preserved renal function referred for CCTA. Methods: We enrolled 180 patients who were referred for CCTA. The serum creatinine (SCr) and estimated glomerular filtration rate (eGFR) levels were measured before, 24 h, and a mean of 4.8 days after CCTA. The amount of unrestricted oral fluid intake for 24 h was checked. The patients were divided into two groups: 106 subjects with a rise in SCr after CCTA (group A); and 74 without (group B). Results: Significant correlations were observed between the amount of oral fluid intake and the percentage changes in SCr (%SCr) (r = -0.66, p < 0.0001) as well as the absolute changes in eGFR ({Delta}eGFR) (r = 0.65, p < 0.0001). The percentage of patients showing hemoglobin-A1c (HbA1c) {>=} 6.5% was greater in group A than in group B (29% vs. 18%, p < 0.001). Patients with HbA1c {>=} 6.5% showed higher %SCr and lower {Delta}eGFR compared to those without it. Multiple regression analysis revealed that the amount of oral fluid intake was the only independent predictor for a rise in SCr ({beta} = -0.731, p < 0.0001). Conclusion: Oral volume intake after CCTA is a very simple but important prophylactic procedure for contrast-induced AKI especially in diabetic patients.

  5. Demonstration of SCR technology for the control of NOx emissions from high-sulfur coal-fired utility boilers

    Energy Technology Data Exchange (ETDEWEB)

    Hinton, W.S. [W.S. Hinton and Associates, Cantonment, FL (United States); Maxwell, J.D.; Healy, E.C.; Hardman, R.R. [Southern Company Services, Inc., Birmingham, AL (United States); Baldwin, A.L. [Dept. of Energy, Pittsburgh, PA (United States)

    1997-12-31

    This paper describes the completed Innovative Clean Coal Technology project which demonstrated SCR technology for reduction of flue gas NO{sub x} emissions from a utility boiler burning US high-sulfur coal. The project was sponsored by the US Department of Energy, managed and co-funded by Southern Company Services, Inc. on behalf of the Southern Company, and also co-funded by the Electric Power Research Institute and Ontario Hydro. The project was located at Gulf Power Company`s Plant Crist Unit 5 (a 75 MW tangentially-fired boiler burning US coals that had a sulfur content ranging from 2.5--2.9%), near Pensacola, Florida. The test program was conducted for approximately two years to evaluate catalyst deactivation and other SCR operational effects. The SCR test facility had nine reactors: three 2.5 MW (5,000 scfm), and operated on low-dust flue gas. The reactors operated in parallel with commercially available SCR catalysts obtained from suppliers throughout the world. Long-term performance testing began in July 1993 and was completed in July 1995. A brief test facility description and the results of the project are presented in this paper.

  6. Impacts of halogen additions on mercury oxidation, in a slipstream selective catalyst reduction (SCR), reactor when burning sub-bituminous coal.

    Science.gov (United States)

    Cao, Yan; Gao, Zhengyang; Zhu, Jiashun; Wang, Quanhai; Huang, Yaji; Chiu, Chengchung; Parker, Bruce; Chu, Paul; Pant, Wei-Ping

    2008-01-01

    This paper presents a comparison of impacts of halogen species on the elemental mercury (Hg(0)) oxidation in a real coal-derived flue gas atmosphere. It is reported there is a higher percentage of Hg(0) in the flue gas when burning sub-bituminous coal (herein Powder River Basin (PRB) coal) and lignite, even with the use of selective catalytic reduction (SCR). The higher Hg(0)concentration in the flue gas makes it difficult to use the wet-FGD process for the mercury emission control in coal-fired utility boilers. Investigation of enhanced Hg(0) oxidation by addition of hydrogen halogens (HF, HCl, HBr, and HI) was conducted in a slipstream reactor with and without SCR catalysts when burning PRB coal. Two commercial SCR catalysts were evaluated. SCR catalyst no. 1 showed higher efficiencies of both NO reduction and Hg(0) oxidation than those of SCR catalyst no. 2. NH3 addition seemed to inhibit the Hg(0) oxidation, which indicated competitive processes between NH3 reduction and Hg(0) oxidation on the surface of SCR catalysts. The hydrogen halogens, in the order of impact on Hg(0) oxidation, were HBr, HI, and HCl or HF. Addition of HBr at approximately 3 ppm could achieve 80% Hg(0) oxidation. Addition of HI at approximately 5 ppm could achieve 40% Hg(0) oxidation. In comparison to the empty reactor, 40% Hg(0) oxidation could be achieved when HCl addition was up to 300 ppm. The enhanced Hg(0) oxidation by addition of HBr and HI seemed not to be correlated to the catalytic effects by both evaluated SCR catalysts. The effectiveness of conversion of hydrogen halogens to halogen molecules or interhalogens seemed to be attributed to their impacts on Hg(0) oxidation.

  7. Recognition and Sensing of Creatinine.

    Science.gov (United States)

    Guinovart, Tomàs; Hernández-Alonso, Daniel; Adriaenssens, Louis; Blondeau, Pascal; Martínez-Belmonte, Marta; Rius, F Xavier; Andrade, Francisco J; Ballester, Pablo

    2016-02-12

    Current methods for creatinine quantification suffer from significant drawbacks when aiming to combine accuracy, simplicity, and affordability. Here, an unprecedented synthetic receptor, an aryl-substituted calix[4]pyrrole with a monophosphonate bridge, is reported that displays remarkable affinity for creatinine and the creatininium cation. The receptor works by including the guest in its deep and polar aromatic cavity and establishing directional interactions in three dimensions. When incorporated into a suitable polymeric membrane, this molecule acts as an ionophore. A highly sensitive and selective potentiometric sensor suitable for the determination of creatinine levels in biological fluids, such as urine or plasma, in an accurate, fast, simple, and cost-effective way has thus been developed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Ranitidine has no influence on tubular creatinine secretion

    NARCIS (Netherlands)

    van den Berg, J. G.; Koopman, M. G.; Arisz, L.

    1996-01-01

    Oral cimetidine competitively inhibits tubular secretion of creatinine. We investigated the potential of oral ranitidine, a comparable H2-receptor antagonist, to block tubular creatinine secretion. In 10 healthy subjects, clearances of inulin and endogenous creatinine were simultaneously measured

  9. Correlation of glomerular filtration rate measurement using Tc-99m DTPA with cystatin-C levels and creatinine clearance for staging of chronic kidney disease

    International Nuclear Information System (INIS)

    Elliyanti, A.; Iskandar, Azmi S.

    2007-01-01

    Full text: The presence of Chronic Kidney Disease (CKD) was established based on kidney damage presence and the level of kidney function through Glomerular filtration rate (GFR). It was also recognized that renal scintigraphy (renogram) using TC-99m DTPA (diethylenetriamine pentacetic acid) has advantages in the measurement of GFR. Recently, serum Cystatin-C is proposed as the new marker of GFR. The aim of this study is to find out the correlation of GFR, derived from renogram, with Cystatin- C levels and Creatinine Clearance (CC) in CKD. Material and Methods: A total of 30 subjects (age mean is 60.8 years, 21 males and 9 females) were enrolled in this study with diagnosis stage 2 of CKD. CKD staging was determined by Cockroft-Gault (CG) equation, taking into account the serum creatinine. Renogram was performed using a single head camera with IV administration of 5 mCi DTPA. Cystatin-C and creatinine clearance (24-hours urine samples) were include in this study. Results: The mean GFR of renogram, Cystatin-C, CC and CG are 64.96 ml/min/1.73m2 (SD 28.047), 53.37 ml/min/1.73m2 (SD 21.29), 58.09 ml/min/1.73m2 (SD 35.45), 46.00 ml/min/1.73m2 (SD 12.06) respectively. There is better correlation between renogram and Cystatin-C (r=0.585, p0.0007) compared renogram and CC (r=0.388, p=0.03) or renogram and CG (r=-0.029, p=0.87). Conclusion: Cystatin-C shows better indicator of GFR than CC and CG. Serum creatinine concentration alone should not be used to assess the level of kidney function in the staging of CKD. (author)

  10. Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay

    NARCIS (Netherlands)

    Kemperman, F. A.; Silberbusch, J.; Slaats, E. H.; van Zanten, A. P.; Weber, J. A.; Krediet, R. T.; Arisz, L.

    1999-01-01

    BACKGROUND: Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this

  11. Verification of serum reference intervals for free light chains in a local South African population.

    Science.gov (United States)

    Zemlin, Annalise E; Rensburg, Megan A; Ipp, Hayley; Germishuys, Jurie J; Erasmus, Rajiv T

    2013-11-01

    Monoclonal serum free light chain measurements are used to follow up and manage patients with monoclonal gammopathies, and abnormal serum free light chain ratios are associated with risk of progression in certain diseases. We aimed to validate the reference intervals in our population. Reference intervals for κ and λ free light chains were established on 120 healthy adults. Creatinine levels were measured to exclude renal dysfunction and serum protein electrophoresis was performed. All creatinine values were within normal limits. After exclusion of subjects with abnormal serum protein electrophoreses, 113 subjects were available for analysis. The 95% reference interval was 6.3-20.6 mg/L for κ free light chains, 8.7-25.9 mg/L for λ free light chains and 0.46-1.23 for free light chain ratio. Most of the values fell within the manufacturer's recommended limits and therefore could be used for our population.

  12. Application and validation of Cox regression models in a single-center series of double kidney transplantation.

    Science.gov (United States)

    Santori, G; Fontana, I; Bertocchi, M; Gasloli, G; Magoni Rossi, A; Tagliamacco, A; Barocci, S; Nocera, A; Valente, U

    2010-05-01

    A useful approach to reduce the number of discarded marginal kidneys and to increase the nephron mass is double kidney transplantation (DKT). In this study, we retrospectively evaluated the potential predictors for patient and graft survival in a single-center series of 59 DKT procedures performed between April 21, 1999, and September 21, 2008. The kidney recipients of mean age 63.27 +/- 5.17 years included 16 women (27%) and 43 men (73%). The donors of mean age 69.54 +/- 7.48 years included 32 women (54%) and 27 men (46%). The mean posttransplant dialysis time was 2.37 +/- 3.61 days. The mean hospitalization was 20.12 +/- 13.65 days. Average serum creatinine (SCr) at discharge was 1.5 +/- 0.59 mg/dL. In view of the limited numbers of recipient deaths (n = 4) and graft losses (n = 8) that occurred in our series, the proportional hazards assumption for each Cox regression model with P DKT (P = .043), and SCr 6 months post-DKT (P = .017). All significant univariate models for graft survival passed the Schoenfeld test. A final multivariate model retained SCr at 6 months (beta = 1.746, P = .042) and donor SCr (beta = .767, P = .090). In our analysis, SCr at 6 months seemed to emerge from both univariate and multivariate Cox models as a potential predictor of graft survival among DKT. Multicenter studies with larger recipient populations and more graft losses should be performed to confirm our findings. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  13. The Effect of Methanolic Extract of Otostegia persica on Serum Glucose Level and Renal Function Indicators in Streptozotocin Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Mahdiye Hedayati

    2012-05-01

    Full Text Available Background: Regarding the antioxidant property of Otostegia persica extract and the role of antioxidants in Diabetes mellitus treatment, in this study the effect of extract on serum glucose level and renal function indicators was determined in diabetic male rats. Materials and Methods: Diabetes mellitus (type I was inducted in male rats using intraperitoneal injection of streptozotocin (STZ (65 mg/kg. To determine blood glucose, urea, and creatinine serum levels; fasting blood samples were collected twice (before STZ injection and 5 days later. The rats with their serum glucose level exceeding 250 mg/dl were considered diabetic and divided into 10 groups separately received Otostegia persica alcoholic extract (100, 200, and 300 mg/kg/day doses, glibenclamide with 600 µg/kg dose and 0.5 ml distilled water for 3 and 6 days using gavage. After 3 and 6 days, blood samples were collected again and glucose, urea, and creatinine serum levels were assessed using spectrophotometry technique by respective kits.Results: Treating diabetic rats by Otostegia persica extract (100, 200, and 300 mg/kg/day doses for 6 days results in a significant decrease of glucose and creatinine, yet an increase of serum urea with 200 mg/kg dose. Also, administration of the extract for 3 days (300 mg/kg reduced glucose, and (in various doses urea and creatinine serum levels. Conclusion: Otostegia persica extract has hypoglycemic effect and administering it in diabetes mellitus not only had no undesirable renal side effects, but also improved renal function to some extent.

  14. Innovative clean coal technology (ICCT): demonstration of selective catalytic reduction (SCR) technology for the control of nitrogen oxide (NOx) emission from high-sulfur, coal-fired boilers - economic evaluation of commercial-scale SCR applications for utility boilers

    International Nuclear Information System (INIS)

    Healy, E.C.; Maxwell, J.D.; Hinton, W.S.

    1996-09-01

    This report presents the results of an economic evaluation produced as part of the Innovative Clean Coal Technology project, which demonstrated selective catalytic reduction (SCR) technology for reduction of NO x emissions from utility boilers burning U.S. high-sulfur coal. The document includes a commercial-scale capital and O ampersand M cost evaluation of SCR technology applied to a new facility, coal-fired boiler utilizing high-sulfur U.S. coal. The base case presented herein determines the total capital requirement, fixed and variable operating costs, and levelized costs for a new 250-MW pulverized coal utility boiler operating with a 60-percent NO x removal. Sensitivity evaluations are included to demonstrate the variation in cost due to changes in process variables and assumptions. This report also presents the results of a study completed by SCS to determine the cost and technical feasibility of retrofitting SCR technology to selected coal-fired generating units within the Southern electric system

  15. Estimation of Body Composition from Urinay Creatinine Excretion

    OpenAIRE

    小室, 史恵; 小宮, 秀一

    1982-01-01

    Simultaneous determinations of total body water, using the deuterium oxide dilution method, and urinary creatinine excretion have been carried out in 26 males and females. Total body water and FFM may be predicted from urinary creatinine excretion by T.B.W.=0.0165 Cr. +17.773. FFM=0.0225 Cr. +17.446. In this subjects a high correlation (r=0.874) was found between T.B.W, FFM and urinary creatinine excretion. It appears that FFM can be predicted from urinary creatinine excretion.

  16. Low cost SCR lamp driver indicates contents of digital computer registers

    Science.gov (United States)

    Cliff, R. A.

    1967-01-01

    Silicon Controlled Rectifier /SCR/ lamp driver is adapted for use in integrated circuit digital computers where it indicates the contents of the various registers. The threshold voltage at which visual indication begins is very sharply defined and can be adjusted to suit particular system requirements.

  17. Atorvastatin and prevention of contrast induced nephropathy following coronary angiography

    Directory of Open Access Journals (Sweden)

    Peyman Bidram

    2015-01-01

    Full Text Available Background: Contrast induced nephropathy (CIN is one of the most common complications after radiographic procedures using intravascular radiocontrast media. The aim of the current study was to assess the effect of atorvastatin on prevention of CIN in patients undergoing coronary angiography. Materials and Methods: In a clinical trial study, 200 patients referred for angiography were randomly divided into two groups of using 80 mg atorvastatin and placebo before the procedure. Furthermore, 100 patients who were under chronic treatment of statins were included as the third group. Serum creatinine (Scr levels before and after the procedure were evaluated and incidence of CIN (post-procedural Scr of >0.5 mg/dl or >25% from baseline was assessed. Results: Mean age of the participants was 60.06 ± 0.69 years and 276 (92% were male. There were no significant differences between group with respect to age and gender. In pre-operation atorvastatin, placebo and long term statin groups, the incidence of CIN was 1%, 2% and 1%, and mean changes of Glomerular filtration rate (GFR was 3.68 ± 1.32, −0.77 ± 1.21 and 1.37 ± 0.86; and mean changes of creatinine (Cr was −0.05 ± 0.02, 0.02 ± 0.02 and −0.01 ± 0.01 respectively. (P = 0.776, 0.026 and 0.041 respectively. In pre-operation atorvastatin group, Cr decreased, and GFR increased significantly (P = 0.019 and 0.007 respectively. Conclusion: pre-operation short term high dose atorvastatin use was associated with a significant decrease in serum Cr level and increase in GFR after angiography.

  18. The effect of the gas composition on hydrogen-assisted NH3-SCR over Ag/Al2O3

    DEFF Research Database (Denmark)

    Tamm, Stefanie; Fogel, Sebastian; Gabrielsson, Pär

    2013-01-01

    In addition to high activity in hydrocarbon-SCR, Ag/Al2O3 catalysts show excellent activity for NOx reduction for H2-assisted NH3-SCR already at 200°C. Here, we study the influence of different gas compositions on the activity of a pre-sulfated 6wt% Ag/Al2O3 catalyst for NOx reduction, and oxidat...

  19. THE COMPARATIVE ANALYSIS OF RENAL FUNCTION IN LIVER DISEASES USING COCKCROFT-GAULT FORMULAE AND CREATININE CLEARANCE

    Directory of Open Access Journals (Sweden)

    Karem Ravi Teja

    2018-01-01

    Full Text Available BACKGROUND Kidney dysfunction in liver disease can be due to different aetiologies and can have diverse manifestations. Most of the abnormalities of kidney function in cirrhosis are of functional origin namely, sodium retention, impaired free water excretion and renal vasoconstriction with decrease in renal perfusion and glomerular filtration rate. Renal dysfunction in chronic liver disease usually follows a progressive course- the final phase being Hepatorenal Syndrome (HRS. MATERIALS AND METHODS This study included patients with chronic liver disease being treated as inpatients in the Department of General Medicine, Konaseema Institute of Medical Sciences, Amalapuram. Evidence for chronic liver disease being defined by a compatible clinical profile (signs of liver cell failure or reduced liver span along with biochemical (altered liver function tests, reversal of albuminglobulin ratio or sonographic evidence (altered echotexture of liver or tissue diagnosis (positive liver biopsy for cirrhosis. RESULTS Eighteen percent, i.e. 5 out of the 28 patients with creatinine clearance more than 60 mL/minute by Cockcroft-Gault formula were found to have creatinine clearance values less than 40 mL/minute when done by timed urine collection P value calculated was found to be less than 0.0001, which is statistically significant. CONCLUSION In chronic liver disease, serum creatinine alone is not a reliable marker to assess renal dysfunction. Calculating creatinine clearance by using Cockcroft-Gault formula overestimates renal function in cirrhotics. Creatinine clearance measured by timed urine collections should be done routinely to assess renal reserve in advanced liver disease. Alcoholism appears to have adverse effect on renal function when compared with other aetiologies of cirrhosis.

  20. Effect of selective catalytic reduction (SCR) on fine particle emission from two coal-fired power plants in China

    Science.gov (United States)

    Li, Zhen; Jiang, Jingkun; Ma, Zizhen; Wang, Shuxiao; Duan, Lei

    2015-11-01

    Nitrogen oxides (NOx) emission abatement of coal-fired power plants (CFPPs) requires large-scaled installation of selective catalytic reduction (SCR), which would reduce secondary fine particulate matter (PM2.5) (by reducing nitrate aerosol) in the atmosphere. However, our field measurement of two CFPPs equipped with SCR indicates a significant increase of SO42- and NH4+ emission in primary PM2.5, due to catalytic enhancement of SO2 oxidation to SO3 and introducing of NH3 as reducing agent. The subsequent formation of (NH4)2SO4 or NH4HSO4 aerosol is commonly concentrated in sub-micrometer particulate matter (PM1) with a bimodal pattern. The measurement at the inlet of stack also showed doubled primary PM2.5 emission by SCR operation. This effect should therefore be considered when updating emission inventory of CFPPs. By rough estimation, the enhanced primary PM2.5 emission from CFPPs by SCR operation would offset 12% of the ambient PM2.5 concentration reduction in cities as the benefit of national NOx emission abatement, which should draw attention of policy-makers for air pollution control.

  1. Serum Creatinine Distinguishes Duchenne Muscular Dystrophy from Becker Muscular Dystrophy in Patients Aged ≤3 Years: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Liang Wang

    2017-05-01

    Full Text Available Here, we investigated correlations between serum creatinine (SCRN levels and clinical phenotypes of dystrophinopathy in young patients. Sixty-eight patients with dystrophinopathy at the Neuromuscular Clinic, The First Affiliated Hospital, Sun Yat-sen University, were selected for this study. The diagnosis of dystrophinopathy was based on clinical manifestation, biochemical changes, and molecular analysis. Some patients underwent muscle biopsies; SCRN levels were tested when patients were ≤3 years old, and reading frame changes were analyzed. Each patient was followed up, and motor function and clinical phenotype were assessed when the same patients were ≥4 years old. Our findings indicated that in young patients, lower SCRN levels were associated with increased disease severity (p < 0.01 and that SCRN levels were the highest in patients exhibiting mild Becker muscular dystrophy (BMD (p < 0.001 and the lowest in patients with Duchenne muscular dystrophy (DMD (p < 0.01 and were significantly higher in patients carrying in-frame mutations than in patients carrying out-of-frame mutations (p < 0.001. SCRN level cutoff values for identifying mild BMD [18 µmol/L; area under the curve (AUC: 0.947; p < 0.001] and DMD (17 µmol/L; AUC: 0.837; p < 0.001 were established. These results suggest that SCRN might be a valuable biomarker for distinguishing DMD from BMD in patients aged ≤3 years and could assist in the selection of appropriate treatment strategies.

  2. Dosing related effects of zoledronic acid on bone markers and creatinine clearance in patients with multiple myeloma and metastatic breast cancer

    DEFF Research Database (Denmark)

    Søe, Kent; Delaissé, Jean-Marie; Jakobsen, Erik H

    2014-01-01

    phase II clinical trial we investigated the effect of Zol treatment on the serum levels of the bone markers collagen type 1 cross-linked C-telopeptide (CTX) and bone specific alkaline phosphatase (bALP) as well as on creatinine clearance (kidney function) in response to dosing and duration of treatment...

  3. Estimating Renal Function in the Elderly Malaysian Patients Attending Medical Outpatient Clinic: A Comparison between Creatinine Based and Cystatin-C Based Equations

    Directory of Open Access Journals (Sweden)

    Maisarah Jalalonmuhali

    2018-01-01

    Full Text Available Background. To assess the performance of different GFR estimating equations, test the diagnostic value of serum cystatin-C, and compare the applicability of cystatin-C based equation with serum creatinine based equation for estimating GFR (eGFR in comparison with measured GFR in the elderly Malaysian patients. Methods. A cross-sectional study recruiting volunteered patients 65 years and older attending medical outpatient clinic. 51 chromium EDTA (51Cr-EDTA was used as measured GFR. The predictive capabilities of Cockcroft-Gault equation corrected for body surface area (CGBSA, four-variable Modification of Diet in Renal Disease (4-MDRD, and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equations using serum creatinine (CKD-EPIcr as well as serum cystatin-C (CKD-EPIcys were calculated. Results. A total of 40 patients, 77.5% male, with mean measured GFR 41.2±18.9 ml/min/1.73 m2 were enrolled. Mean bias was the smallest for 4-MDRD; meanwhile, CKD-EPIcr had the highest precision and accuracy with lower limit of agreement among other equations. CKD-EPIcys equation did not show any improvement in GFR estimation in comparison to CKD-EPIcr and MDRD. Conclusion. The CKD-EPIcr formula appears to be more accurate and correlates better with measured GFR in this cohort of elderly patients.

  4. SCR96, a small cysteine-rich secretory protein of Phytophthora cactorum, can trigger cell death in the Solanaceae and is important for pathogenicity and oxidative stress tolerance.

    Science.gov (United States)

    Chen, Xiao-Ren; Li, Yan-Peng; Li, Qi-Yuan; Xing, Yu-Ping; Liu, Bei-Bei; Tong, Yun-Hui; Xu, Jing-You

    2016-05-01

    Peptides and small molecules produced by both the plant pathogen Phytophthora and host plants in the apoplastic space mediate the relationship between the interplaying organisms. Various Phytophthora apoplastic effectors, including small cysteine-rich (SCR) secretory proteins, have been identified, but their roles during interaction remain to be determined. Here, we identified an SCR effector encoded by scr96, one of three novel genes encoding SCR proteins in P. cactorum with similarity to the P. cactorum phytotoxic protein PcF. Together with the other two genes, scr96 was transcriptionally induced throughout the developmental and infection stages of the pathogen. These genes triggered plant cell death (PCD) in the Solanaceae, including Nicotiana benthamiana and tomato. The scr96 gene did not show single nucleotide polymorphisms in a collection of P. cactorum isolates from different countries and host plants, suggesting that its role is essential and non-redundant during infection. Homologues of SCR96 were identified only in oomycetes, but not in fungi and other organisms. A stable protoplast transformation protocol was adapted for P. cactorum using green fluorescent protein as a marker. The silencing of scr96 in P. cactorum caused gene-silenced transformants to lose their pathogenicity on host plants and these transformants were significantly more sensitive to oxidative stress. Transient expression of scr96 partially recovered the virulence of gene-silenced transformants on plants. Overall, our results indicate that the P. cactorum scr96 gene encodes an important virulence factor that not only causes PCD in host plants, but is also important for pathogenicity and oxidative stress tolerance. © 2015 BSPP AND JOHN WILEY & SONS LTD.

  5. Opium and heroin alter biochemical parameters of human's serum.

    Science.gov (United States)

    Kouros, Divsalar; Tahereh, Haghpanah; Mohammadreza, Afarinesh; Minoo, Mahmoudi Zarandi

    2010-05-01

    Iran is a significant consumer of opium, and, generally, of opioids, in the world. Addiction is one of the important issues of the 21st century and is an imperative issue in Iran. Long-term consumption of opioids affects homeostasis. To determine the effects of opium and heroin consumption on serum biochemical parameters. In a cross-sectional study, subjects who had consumed heroin (n = 35) or opium (n = 42) for more than two years and 35 nonaddict volunteers as the control group were compared in regard to various biochemical parameters such as fasting blood sugar (FBS), Na(+), K(+), Ca(2+), blood urea nitrogen (BUN), uric acid (UA), triglyceride (TG), cholesterol, creatinine, and total protein. Chromatography was used to confirm opioid consumption, and the concentration of biochemical parameters was determined by laboratory diagnostic tests on serum. No significant differences were found in Na(+), Ca(2+), BUN, UA, TG, creatinine, and total protein concentrations among the three groups. FBS, K(+), and UA levels were significantly lower in opium addicts compared to the control group. Serum Ca(2+) concentration of heroin addicts showed a significant decrease compared to that of the control group. Both addict groups showed a significant decrease in serum cholesterol levels. Chronic use of opium and heroin can change serum FBS, K(+), Ca(2+), UA, and cholesterol. This study, one of few on the effects of opium on serum biochemical parameters in human subjects, has the potential to contribute to the investigation of new approaches for further basic studies.

  6. Analysis of the offshore installations regulations 2005 (SCR05r12) within Brazilian reality; Analise da regulacao das instalacoes offshore 2005 (SCR05r12) dentro da realidade brasileira

    Energy Technology Data Exchange (ETDEWEB)

    Nalvarte, Gladys; Storch, Rafael; Araujo, Pedro; Oliveira, Luiz Fernando [Det Norske Veritas (Brazil)

    2008-07-01

    The main motivation for the present study is the modifications presented in the guidance Offshore Installations (Safety Case) Regulations 2005 (SCR05 r12), released by HSE, in relation to the Offshore Installation Regulation 1992, SCR92. A critical analysis of the new regulation issued by HSE is developed and conclusions are obtained. A cost-benefit approach applied to the Quantitative Risk Analysis (QRA), using computational fluid dynamics (CFD) techniques, is suggested. Thereby, a method to identify the mitigation measures that most reduces the risks with the minimum cost is obtained. On the other hand, this new QRA approach combined with a cost benefit analysis is intended to have a total cost diminished. In this case, the cost of the new QRA study is dependant on the number of reevaluations needed to determine the mitigation measures to be applied. (author)

  7. Validation of daily urinary creatinine excretion measurement by muscle-creatinine equivalence.

    Science.gov (United States)

    Iacone, Roberto; D'Elia, Lanfranco; Guida, Bruna; Barbato, Antonio; Scanzano, Clelia; Strazzullo, Pasquale

    2018-02-09

    Twenty-four-hour urinary creatinine excretion (24hUCrE) is strongly correlated with skeletal muscle mass (SMM). This study suggests how to exploit the power of the SMM-24hUCrE correlation to assess the accuracy of 24hUCrE measurement. Four hundred and sixty-six men, a subgroup of participants in the 2002-2004 follow-up examination of the Olivetti Heart Study, performed a 24-h urine collection to measure 24hUCrE and underwent bioelectrical impedance analysis to evaluate SMM. Linear regression analysis between 24hUCrE and SMM was used to calculate the muscle-creatinine equivalence and to develop an equation to predict the 24hUCrE depending on SMM. The accuracy of the 24hUCrE measurement was assessed using the change in the SMM-24hUCrE correlation coefficient upon variation in the percentage deviation (%D) between the measured and predicted 24hUCrE. The calculated muscle-creatinine equivalence was 1 g of 24hUCrE = 22.73 kg of SMM. The %Ds and the corresponding SMM-24hUCrE correlation coefficients were as follows: %D = 3.0, r = .997; %D = 4.7, r = .989; %D = 8.1, r = .963; %D = 10.5, r = .940; %D = 12.6, r = .909; %D = 18.9, r = .825; %D = 25.8, r = .707; %D = 33.5, r = .595; %D = 41.4, r = .453. The increase in %D corresponds to a reduced correlation between muscle mass and creatinine excretion, which indicated a poor performance in the measurement of the 24hUCrE. For studies on single individuals, where small variations in 24hUCrE could be significant, a %D up to 12.6% is suggested; on the other hand, a wider %D interval could be acceptable for population studies. © 2018 Wiley Periodicals, Inc.

  8. Generation of fatty acids from 1,2-dipalmitoyl-sn-glycero-3-phosphocholine/cardiolipin liposomes that stabilize recombinant human serum albumin.

    Science.gov (United States)

    Frahm, Grant E; Cameron, Brooke E; Smith, Jeffrey C; Johnston, Michael J W

    2013-06-01

    At elevated temperatures, studies have shown that serum albumin undergoes irreversible changes to its secondary structure. Anionic fatty acids and/or anionic surfactants have been shown to stabilize human serum albumin (HSA) against thermal denaturation through bridging hydrophobic domains and cationic amino acids residues of the protein. As albumin can readily interact with a variety of liposomes, this study proposes that cardiolipin delivered via 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) liposomes can improve the thermal stability of recombinant HSA produced in Saccharomyces cerevisiae (ScrHSA) in a similar manner to anionic fatty acids. Thermal stability and structure of ScrHSA in the absence and presence of DPPC/cardiolipin liposomes was assessed with U/V circular dichroism spectropolarimetry and protein thermal stability was confirmed with differential scanning calorimetry. Although freshly prepared DPPC/cardiolipin liposomes did not improve the stability of ScrHSA, DPPC/cardiolipin liposomes incubated at room temperature for 7 d (7dRT) dramatically improved the thermal stability of the protein. Mass spectrometry analysis identified the presence of fatty acids in the 7dRT liposomes, not identified in freshly prepared liposomes, to which the improved stability was attributed. The generation of fatty acids is attributed to either the chemical hydrolysis or oxidative cleavage of the unsaturated acyl chains of cardiolipin. By modulating the lipid composition through the introduction of lipids with higher acyl chain unsaturation, it may be possible to generate the stabilizing fatty acids in a more rapid manner.

  9. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  10. Serum cystatin C and urinary neutrophil gelatinase-associated lipocalin in pediatric acute kidney injury; a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Neamatollah Ataei

    2017-10-01

    Full Text Available Background: Acute kidney injury (AKI refers to insults that lead to decreased kidney function within hours to weeks and can be associated with complications including chronic kidney failure, end-stage renal disease and even death. Although various biomarkers have been proposed to predict AKI in children, but no consensus has been reached on the best diagnostic method. Accordingly, the present study aimed to assess the correlation between urine NGAL levels and development of AKI in children and determine which one of the biomarkers of urine NGAL, serum Cystatin C and serum creatinine has a stronger association with AKI in the pediatric population. Methods: The present cross-sectional study was conducted on children younger than 14 years of age, hospitalized in the intensive care unit of Children’s Medical Centre in Tehran, Iran, during 2016. Urine NGAL, serum Cystatin C and serum creatinine levels of these subjects were measured on admission to the intensive care unit. The concentrations of serum Cystatin C and serum creatinine were measured again after 48 hours to determine the AKI status of the subjects. Data were analyzed to determine the association between GFR and the concentrations of evaluated biomarkers and to compare the levels of biomarkers between the four groups of no AKI, injury, failure, loss and end-stage. Results: A total of 104 children (59 boys and 45 girls, average age=28.0±3.5 months were included in this study. The mean level of uNGAL on admission in the No-AKI group (153.79±29.82 was significantly lower than the children in the injury (1225.0 ±275.0 and failure (756.56±147.79 groups (df:3, 100; F=10.74; p<0.0001. The mean concentration of Cystatin C on admission in the three groups of risk (0.94±0.30, injury (1.75±0.05 and failure (1.75±0.36 was also significantly higher than the No-AKI (0.27±0.04 (df:3, 100; F=19.21; p<0.0001. However, there was no significant correlation between the level of serum creatinine on

  11. Preproghrelin Leu72Met polymorphism predicts a lower rate of developing renal dysfunction in type 2 diabetic nephropathy.

    Science.gov (United States)

    Lee, Dae-Yeol; Kim, Sun-Young; Jo, Dae-Sun; Hwang, Pyoung Han; Kang, Kyung Pyo; Lee, Sik; Kim, Won; Park, Sung Kwang

    2006-07-01

    Ghrelin is a novel peptide hormone, which exerts somatotropic, orexigenic and adipogenic effects. Recent studies have shown that the preproghrelin Leu72Met polymorphism is associated with serum creatinine (Scr) concentration in type 2 diabetes; 72Met carriers exhibited lower Scr levels as compared with the 72Met non-carriers. We hypothesized that the preproghrelin Leu72Met polymorphism is associated with a lower rate of developing renal dysfunction in patients with type 2 diabetic nephropathy. The preproghrelin Leu72Met polymorphism was investigated using PCR techniques in 138 patients with diabetic nephropathy divided into two groups, one with normal renal function and the other with renal dysfunction. Determination of the frequency of the preproghrelin Leu72Met polymorphism was the main outcome measure. The frequency of the Leu72Met polymorphism in diabetic nephropathy was significantly lower in patients with renal dysfunction (15.9%, P polymorphism was also associated with serum total cholesterol levels in diabetic nephropathy patients with renal dysfunction; the 72Met carriers had lower total cholesterol levels than the 72Met non-carriers (P < 0.05). These data suggest that 72Met carrier status may be used as a marker predicting a lower chance of developing renal dysfunction in diabetic nephropathy.

  12. Bmi-1 plays a critical role in the protection from acute tubular necrosis by mobilizing renal stem/progenitor cells

    International Nuclear Information System (INIS)

    Lv, Xianhui; Yu, Zhenzhen; Xie, Chunfeng; Dai, Xiuliang; Li, Qing; Miao, Dengshun; Jin, Jianliang

    2017-01-01

    The regeneration of injured tubular cell occurs primarily from intrinsic renal stem/progenitor cells (RSCs) labeled with CD24 and CD133 after acute tubular necrosis (ATN). Bmi-1 plays a crucial role in regulating self-renewal, differentiation and aging of multiple adult stem cells and progenitor cells. Bmi-1 was rapidly elevated in the induction of adult kidney regeneration by renal injury. To determine whether Bmi-1 maintained mobilization of RSCs in the protection from ATN, glycerol-rhabdomyolysis-induced ATN were performed in wild type (WT) and Bmi-1-deficient (Bmi-1 −/− ) mice. Their ATN phenotypes were analyzed; CD24 and CD133 double positive (CD24 + CD133 + ) cells were measured; and the levels of serum urea nitrogen (SUN) and serum creatinine (SCr) were detected. We found that CD24 + CD133 + RSCs were mobilized in WT ATN mice with the increased expression of Bmi-1; Bmi-1 deficiency led to increased tubular cast formation and necrosis, elevated levels of SUN and SCr, decreased tubular proliferation, and immobilized ratio of RSCs in ATN. These findings indicated that Bmi-1 played a critical role in the protection from ATN by maintaining mobilization of RSCs and would be a novel therapeutic target for preventing the progression of ATN.

  13. Perioperative change in creatinine following cardiac surgery with cardiopulmonary bypass is useful in predicting acute kidney injury: a single-centre retrospective cohort study.

    Science.gov (United States)

    Takaki, Shunsuke; Shehabi, Yahya; Pickering, John W; Endre, Zoltan; Miyashita, Tetsuya; Goto, Takahisa

    2015-10-01

    Acute kidney injury is common following cardiac surgery. Experimental models of acute kidney injury suggest that successful therapy should be implemented within 24-48 h of renal injury. However, it is difficult to detect acute kidney injury shortly after cardiac surgery, because creatinine concentration is diluted by cardiopulmonary bypass. We hypothesized that, following cardiopulmonary bypass, creatinine reduction ratios would correlate with haematocrit reduction ratios and would be associated with the incidence of acute kidney injury. We collected demographic and blood test data from consecutive patients (n = 1137) who had undergone cardiac surgery with cardiopulmonary bypass. The creatinine reduction ratio was calculated as follows: (preoperative creatinine-postoperative creatinine)/preoperative creatinine. Patients were assigned to either of two groups. The first group (Group 1) was used to determine the threshold for acute kidney injury, and the second group (Group 2) was used to assess diagnostic performance. Acute kidney injury was defined as an increase in serum creatinine level >0.3 mg/dl or >150% from baseline. The incidence of acute kidney injury was 14.5% (79/545) in Group 1 and 15.5% (92/592) in Group 2. Postoperatively, creatinine concentration correlated strongly with haematocrit concentration (Pearson's r(2): 0.91). In Group 1, the area under the receiver operating characteristic curve, sensitivity and specificity were 0.71, 64.1 and 66.4%, respectively, for creatinine reduction ratios of creatinine reduction ratio performance were 4.3 (95% confidence interval 2.6-7.0), 0.27 (0.21-0.32), 0.92 (0.89-0.95) and 3.42 (2.22-5.27), respectively. The creatinine reduction ratio may be associated with perioperative renal injury. Therefore, it is a good diagnostic indicator with high performance, and may be useful in detecting acute kidney injury at an earlier stage relative to conventional means. In addition, using creatinine reduction ratios in this manner

  14. Investigation of PCDD/F emissions from mobile source diesel engines: impact of copper zeolite SCR catalysts and exhaust aftertreatment configurations.

    Science.gov (United States)

    Liu, Z Gerald; Wall, John C; Barge, Patrick; Dettmann, Melissa E; Ottinger, Nathan A

    2011-04-01

    This study investigated the impact of copper zeolite selective catalytic reduction (SCR) catalysts and exhaust aftertreatment configurations on the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from mobile source diesel engines. Emissions of PCDD/Fs, reported as the weighted sum of 17 congeners called the toxic equivalency quotient (TEQ), were measured using a modified EPA Method 0023A in the absence and presence of exhaust aftertreatment. Engine-out emissions were measured as a reference, while aftertreatment configurations included various combinations of diesel oxidation catalyst (DOC), diesel particulate filter (DPF), Cu-zeolite SCR, Fe-zeolite SCR, ammonia oxidation catalyst (AMOX), and aqueous urea dosing. In addition, different chlorine concentrations were evaluated. Results showed that all aftertreatment configurations reduced PCDD/F emissions in comparison to the engine-out reference, consistent with reduction mechanisms such as thermal decomposition or combined trapping and hydrogenolysis reported in the literature. Similarly low PCDD/F emissions from the DOC-DPF and the DOC-DPF-SCR configurations indicated that PCDD/F reduction primarily occurred in the DOC-DPF with no noticeable contribution from either the Cu- or Fe-zeolite SCR systems. Furthermore, experiments performed with high chlorine concentration provided no evidence that chlorine content has an impact on the catalytic synthesis of PCDD/Fs for the chlorine levels investigated in this study.

  15. Low-temperature SCR of NO with NH{sub 3} over activated semi-coke composite-supported rare earth oxides

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jinping; Yan, Zheng; Liu, Lili; Zhang, Yingyi; Zhang, Zuotai; Wang, Xidong, E-mail: xidong@pku.edu.cn

    2014-08-01

    The catalysts with different rare earth oxides (La, Ce, Pr and Nd) loaded onto activated semi-coke (ASC) via hydrothermal method are prepared for the selective catalytic reduction (SCR) of NO with NH{sub 3} at low temperature (150–300 °C). It is evidenced that CeO{sub 2} loaded catalysts present the best performance, and the optimum loading amount of CeO{sub 2} is about 10 wt%. Composite catalysts by doping La, Pr and Nd into CeO{sub 2} are prepared to obtain further improved catalytic properties. The SCR mechanism is investigated through various characterizations, including XRD, Raman, XPS and FT-IR, the results of which indicate that the oxygen defect plays an important role in SCR process and the doped rare earth elements effectively serve as promoters to increase the concentration of oxygen vacancies. It is also found that the oxygen vacancies in high concentration are favored for the adsorption of O{sub 2} and further oxidation of NO, which facilitates a rapid progressing of the following reduction reactions. The SCR process of NO with NH{sub 3} at low temperature over the catalysts of ASC composite-supported rare earth oxides mainly follows the Langmuir–Hinshlwood mechanism.

  16. Creatinine plasma at uncontrolled type 2 diabetes mellitus and controlled type 2 diabetes mellitus patients at primary health care in Binjai city, Indonesia

    Science.gov (United States)

    Rusdiana; Savira, M.; Syahputra, M.; Santoso, A.

    2018-03-01

    The aim of the study knowing the comparison creatinine plasma levels at uncontrolled type 2 diabetes mellitus and controlled type 2 diabetes mellitus patients at Primary Health Care in Binjai city of North Sumatera in Indonesia. This cross-sectional study was conductedon 40 type 2 Diabetes Mellitus patients who attended Primary Health Care in Binjai. Patients with age > 40 years old, (both sexes) were included in the study. We recorded different demographic parameter as age, Body Mass Index, Blood Pressure, and personal history status. And we examined the biochemicalparameters including Hba1c, Fasting Blood Sugar Levels (FBL) and creatinine serum. We separated into two groups base on HbA1c test, controlled type 2 diabetes mellitus and uncontrolled type 2 diabetes mellitus. We measured FBL by using the portable measuring instrument, and Thamrin clinical laboratory measured Hba1c, andwe measured creatinine plasmaby spectrophotometry in Biochemistry laboratory. With statistical analysis using T-test found that there was asignificant differencein creatinine plasma levels between uncontrolled type 2 diabetes mellitus with controlled type 2 diabetes mellitus (p<0.005).

  17. Development of Optimal Catalyst Designs and Operating Strategies for Lean NOx Reduction in Coupled LNT-SCR Systems

    Energy Technology Data Exchange (ETDEWEB)

    Harold, Michael [Univ. of Houston, TX (United States); Crocker, Mark [Univ. of Kentucky, Lexington, KY (United States); Balakotaiah, Vemuri [Univ. of Houston, TX (United States); Luss, Dan [Univ. of Houston, TX (United States); Choi, Jae-Soon [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dearth, Mark [Ford Motor Company, Dearborn, MI (United States); McCabe, Bob [Ford Motor Company, Dearborn, MI (United States); Theis, Joe [Ford Motor Company, Dearborn, MI (United States)

    2013-09-30

    Oxides of nitrogen in the form of nitric oxide (NO) and nitrogen dioxide (NO2) commonly referred to as NOx, is one of the two chemical precursors that lead to ground-level ozone, a ubiquitous air pollutant in urban areas. A major source of NOx} is generated by equipment and vehicles powered by diesel engines, which have a combustion exhaust that contains NOx in the presence of excess O2. Catalytic abatement measures that are effective for gasoline-fueled engines such as the precious metal containing three-way catalytic converter (TWC) cannot be used to treat O2-laden exhaust containing NOx. Two catalytic technologies that have emerged as effective for NOx abatement are NOx storage and reduction (NSR) and selective catalytic reduction (SCR). NSR is similar to TWC but requires much larger quantities of expensive precious metals and sophisticated periodic switching operation, while SCR requires an on-board source of ammonia which serves as the chemical reductant of the NOx. The fact that NSR produces ammonia as a byproduct while SCR requires ammonia to work has led to interest in combining the two together to avoid the need for the cumbersome ammonia generation system. In this project a comprehensive study was carried out of the fundamental aspects and application feasibility of combined NSR/SCR. The project team, which included university, industry, and national lab researchers, investigated the kinetics and mechanistic features of the underlying chemistry in the lean NOx trap (LNT) wherein NSR was carried out, with particular focus on identifying the operating conditions such as temperature and catalytic properties which lead to the production of ammonia in the LNT. The performance features of SCR on both model and commercial catalysts focused on the synergy between the LNT and SCR converters in terms of utilizing the upstream-generated ammonia and

  18. Mechanism of renal excretion of creatinine by the pony

    International Nuclear Information System (INIS)

    Finco, D.R.; Groves, C.

    1985-01-01

    Free-flow and stop-flow procedures conducted on 2 female and 2 testosterone-treated castrated male ponies indicated that [ 14 C]inulin and exogenous creatinine clearance values were the same. These results indicated that creatinine was neither reabsorbed nor secreted by the renal tubules and that exogenous creatinine clearance was an accurate method for determining glomerular filtration rate. As in other species which have been studied, endogenous creatinine clearance probably underestimated glomerular filtration rate because of the presence of noncreatinine chromogens in plasma

  19. Detecting microalbuminuria by urinary albumin/creatinine concentration ratio

    DEFF Research Database (Denmark)

    Jensen, J S; Clausen, P; Borch-Johnsen, K

    1997-01-01

    BACKGROUND: Microalbuminuria, i.e. a subclinical increase of the albumin excretion rate in urine, may be a novel atherosclerotic risk factor. This study aimed to test whether microalbuminuria can be identified by measurement of urinary albumin concentration or urinary albumin/creatinine concentra......BACKGROUND: Microalbuminuria, i.e. a subclinical increase of the albumin excretion rate in urine, may be a novel atherosclerotic risk factor. This study aimed to test whether microalbuminuria can be identified by measurement of urinary albumin concentration or urinary albumin/creatinine...... not included. Urinary albumin (Ualb) and creatinine (Ucreat) concentrations were measured in an overnight collected sample by enzyme-linked immunosorbent and colorimetric assays, respectively. Urinary albumin excretion rate (UAER) and urinary albumin/creatinine concentration ratio (Ualb/Ucreat) were calculated......, and 73%, 97%, and 73% for Ualb/Ucreat, respectively. CONCLUSIONS: It is concluded that measurement of the albumin/creatinine concentration ratio is a specific and quite sensitive alternative to measurement of the urinary albumin excretion rate in timed collections, when screening for microalbuminuria....

  20. Surface Species and Metal Oxidation State during H2-Assisted NH3-SCR of NOx over Alumina-Supported Silver and Indium

    Directory of Open Access Journals (Sweden)

    Linda Ström

    2018-01-01

    Full Text Available Alumina-supported silver and indium catalysts are investigated for the hydrogen-assisted selective catalytic reduction (SCR of NOx with ammonia. Particularly, we focus on the active phase of the catalyst and the formation of surface species, as a function of the gas environment. Diffuse reflectance ultraviolet-visible (UV-vis spectroscopy was used to follow the oxidation state of the silver and indium phases, and in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS was used to elucidate the formation of surface species during SCR conditions. In addition, the NOx reduction efficiency of the materials was evaluated using H2-assisted NH3-SCR. The DRIFTS results show that the Ag/Al2O3 sample forms NO-containing surface species during SCR conditions to a higher extent compared to the In/Al2O3 sample. The silver sample also appears to be more reduced by H2 than the indium sample, as revealed by UV-vis spectroscopic experiments. Addition of H2, however, may promote the formation of highly dispersed In2O3 clusters, which previously have been suggested to be important for the SCR reaction. The affinity to adsorb NH3 is confirmed by both temperature programmed desorption (NH3-TPD and in situ DRIFTS to be higher for the In/Al2O3 sample compared to Ag/Al2O3. The strong adsorption of NH3 may inhibit (self-poison the NH3 activation, thereby hindering further reaction over this catalyst, which is also shown by the lower SCR activity compared to Ag/Al2O3.

  1. Effects of hydrochlorothiazide and furosemide on creatinine ...

    African Journals Online (AJOL)

    Hydrochlorothiazide and furosemide have been reported to alter the glomerular filtration rate (GFR) and possibly the creatinine excretion by the kidneys. Also, therapy with these diuretics, especially in the elderly, can be complicated by volume depletion resulting in prerenal azotemia. Creatinine clearance (Clcr) is ...

  2. An SCR inverter for electric vehicles

    Science.gov (United States)

    Latos, T.; Bosack, D.; Ehrlich, R.; Jahns, T.; Mezera, J.; Thimmesch, D.

    1980-01-01

    An inverter for an electric vehicle propulsion application has been designed and constructed to excite a polyphase induction motor from a fixed propulsion battery source. The inverter, rated at 35kW peak power, is fully regenerative and permits vehicle operation in both the forward and reverse directions. Thyristors are employed as the power switching devices arranged in a dc bus commutated topology. This paper describes the major role the controller plays in generating the motor excitation voltage and frequency to deliver performance similar to dc systems. Motoring efficiency test data for the controller are presented. It is concluded that an SCR inverter in conjunction with an ac induction motor is a viable alternative to present dc vehicle propulsion systems on the basis of performance and size criteria.

  3. Effects of Irbesartan combined Atorvastatin on serum levels of Cys C, Hcy, TNF-α, ET, TGF-b1 in patients with early diabetic nephropathyn

    Directory of Open Access Journals (Sweden)

    Abudula.Reziwanguli

    2017-10-01

    Full Text Available Objective: To observe the effects of Irbesartan combined with Atorvastatin on early diabetic nephropathy patients’ serum Cys C, Hcy, TNF-α, ET and TGF-b1 levels. Methods: A total of 60 early diabetic nephropathy patients were randomly divided into observation group (30 cases and control group (30 cases. Observation group: Irbesartan combined with Atorvastatin; control group: patients were treated only by Irbesartan. Recording and comparing the levels of Cys C, Hcy, TNF-α, ET and TGF-b1 before and after treatment. Results: (1 Before treatment, there was no statistically significant difference in the serum FBG, TG, Scr, BUN levels between the two groups. After treatment, compared with the same group before treatment, the serum TG, Scr, BUN levels of the two groups were significantly lower, and those levels of observation group were significantly better than the control group, the difference between two groups was statistically significant; (2 Before treatment, there was no statistically significant difference in the serum Cys C, Hcy, TNF-α, ET, TGF-b1 levels between the two groups. After treatment, compared with the same group before treatment, the serum Cys C, Hcy, TNF-α, ET, TGF-b1 levels of the two groups were significantly lower, and those levels of observation group were significantly better than the control group, the difference between two groups was statistically significant. Conclusion: Irbesartan combined with Atorvastatin for early diabetic nephropathy patients can reduce the levels of serum Cys C, Hcy, TNF-α, ET, TGF-b1 and be beneficial to protect their nephritic function.

  4. Redox behaviour of vanadium during hydrogen-oxygen exposure of the V2O5-WO3/TiO2 SCR catalyst at 250 degrees C

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes; Rasmussen, Søren B.; Mikolajska, Ewelina

    2011-01-01

    of H-2 (0-2%) in an 8% O-2/N-2 mixture, where the SCR activity was measured before and after the hydrogen treatment. The results show that the activity of the SCR catalyst is only negligibly affected during exposure to the H-2/O-2 gas and in all cases it returned reversibly to the initial NOx...... conversion rate after reexposure to the standard NH3-SCR gas. In situ electron paramagnetic resonance (EPR) and UV-vis spectroscopy at 250 degrees C suggest that a significant part of V4+ present during SCR conditions was oxidized to V5+ during exposure to 2% H-2 + 8% O-2. However, the distribution...

  5. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  6. Parameter estimation and analysis of an automotive heavy-duty SCR catalyst model

    DEFF Research Database (Denmark)

    Åberg, Andreas; Widd, Anders; Abildskov, Jens

    2017-01-01

    A single channel model for a heavy-duty SCR catalyst was derived based on first principles. The model considered heat and mass transfer between the channel gas phase and the wash coat phase. The parameters of the kinetic model were estimated using bench-scale monolith isothermal data. Validation ...

  7. Adaptive Model Predictive Control of Diesel Engine Selective Catalytic Reduction (SCR) Systems

    Science.gov (United States)

    McKinley, Thomas L.

    2009-01-01

    Selective catalytic reduction or SCR is coming into worldwide use for diesel engine emissions reduction for on- and off-highway vehicles. These applications are characterized by broad operating range as well as rapid and unpredictable changes in operating conditions. Significant nonlinearity, input and output constraints, and stringent performance…

  8. Population pharmacokinetics of teicoplanin in hospitalized elderly patients using cystatin C as an indicator of renal function.

    Science.gov (United States)

    Kasai, Hidefumi; Tsuji, Yasuhiro; Hiraki, Yoichi; Tsuruyama, Moeko; To, Hideto; Yamamoto, Yoshihiro

    2018-04-01

    Serum cystatin C (CysC) has recently been proposed as an alternative marker to serum creatinine (SCR) for estimating renal clearance. In the present study, we performed a population pharmacokinetic analysis of teicoplanin (TEIC), which is mainly eliminated through the kidneys, using CysC as a predictor for renal clearance. Thirty-six patients with MRSA infections who were administrated to the National Hospital Organization Beppu Medical Center between January 2012 and December 2013 were enrolled and gave 123 sets of blood TEIC concentration data. Renal clearance was estimated by the Hoek equation using CysC, by creatinine clearance predicted by the Cockcroft-Gault equation using SCR, or directly by CysC. One compartment open model with inter-individual variabilities for renal clearance and the volume of distribution as well as an additional residual error model was used to estimate population pharmacokinetic parameters for TEIC. The model with the best predictability was that with CysC as a predictor for renal clearance; it showed better significance than the models using estimated the glomerular filtration rate by the Hoek equation or CLcr. The final model was as follows: CL (L/hr) = 0.510 × (CysC/1.4) -0.68  × Total body weight/60 0.81 , omega (CL) = 19.8% CV, VC (L) = 78.1, omega (V) = 42.7% CV. The present results show the usefulness of CysC to more accurately predict the pharmacokinetics of drugs mainly eliminated through the kidneys, such as TEIC. However, since the sample size in this study was relatively small, further investigations on renal clearance predictability using CysC are needed. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Assessment of renal function with 99Tcm-DTPA renal dynamic imaging in neonatal hydronephrosis

    International Nuclear Information System (INIS)

    Jiang Lixin; Guo Zongyuan; Wu Rongde; Yu Qihai; Liu Zhanfeng

    2004-01-01

    Objective: To assess the renal function in neonatal hydronephrosis with 99 Tc m -DTPA renal imaging. Methods: Eighteen unilateral hydronephrotic kidneys and 12 normal kidneys were studied by 99 Tc m -DTPA renal dynamic imaging , and glomerular filtration rate (GFR) quantitative analysis was also performed. Blood urea nitrogen (BUN), serum creatinine (SCr) and hemoglobin (Hb) were determined simultaneously and the correlations between GFR and each of these parameters were analyzed. Results: Positive correlation was discovered between GFR and Hb in neonates with moderate or severe hydronephrosis (r=0.414, 0.667, P 0.05). The renal function was decreased significantly in moderate and severe neonatal hydronephrosis (P 99 Tc m -DTPA renal dynamic imaging GFR is an ideal marker for estimating renal function in neonatal hydronephrosis; SCr could be a marker for renal damage especially in moderate and severe neonatal hydronephrosis; BUN could not be a marker for evaluating renal function in neonatal hydronephrosis. Neonates with hydronephrosis should be referred for surgical procedures as soon as possible in the early stage

  10. Rutin (quercetin rutinoside) induced protein-energy malnutrition in chronic kidney disease, but quercetin acted beneficially.

    Science.gov (United States)

    Hsieh, Chiu-Lan; Peng, Chiung-Chi; Chen, Kuan-Chou; Peng, Robert Y

    2013-07-31

    Nutraceutically, much of the literature has indicated that an aglycon and its related glycoside would act similarly. However, controversial reports are accumulating. We hypothesize that rutin (RT) and quercetin (QT) pharmacodynamically could act differently. To confirm this, doxorubicin (DR) (8.5 mg/kg) was used to induce rat chronic kidney disease (CKD) and then treated with QT and RT (each 70 mg/kg body weight per day) for 13 weeks. QT exhibited better body weight gaining effect (420 ± 45) vs RT, 350 ± 57 g/rat (p protein-energy malnutrition". RT stimulated serum creatinine (sCr) production to reach 6.0 ± 0.9 mg/dL (p < 0.001). QT did not alter the sCr level. RT but not QT induced uremia and hypercreatininemia. DR significantly downregulated Bcl-2, but highly upregulated Bax, Bad, and cleaved caspase-3, implicating the intrinsic mitochondrial pathway. DR damaged DNA, but QT completely rescued such an effect and recovered renal amyloidosis and collagen deposition. Conclusively, RT and QT act differently, and RT is inferior to QT with respect to treating CKD.

  11. Study of serum levels of calcium, phosphorus and alkaline phosphatase in chronic kidney disease

    Directory of Open Access Journals (Sweden)

    R. Freethi

    2016-03-01

    Full Text Available Chronic kidney disease (CKD is a worldwide public health problem, with increasing prevalence and lethal adverse outcomes like progressive loss of kidney function, cardiovascular disease and premature death. Disturbances in mineral metabolism and bone disease are common complications of CKD and an important cause of morbidity and decreased quality of life in patients with CKD. Patients with renal failure have an increased risk of cardiovascular mortality that may be due in part to vascular calcification. To measure serum levels of calcium, phosphorus and alkaline phosphatase in patients in various stages of CKD and to correlate the same with creatinine and estimated Glomerular Filtration Rate (eGFRvalues. This is a cross sectional study done at Thanjavur Medical College Hospital. 60 CKD patients and 50 healthy controls were enrolled in this study. Serum levels of creatinine, calcium, phosphorus and alkaline phosphatase were measured and eGFR values correlated with the serum creatinine. The mean values of creatinine (4.9 ± 2.23 mg/dl, cal cium (9.8 ± 0.456 mg/dl , phosphorus (4.19 ± 0.404 mg/dl and alkaline phosphatase (94.01 ± 15.10 U/L in the stu dy group are significantly higher than the control group in which the mean levels are 0.89 ± 0.102 mg/dl, 10.17 ± 0.37 mg/dl, 4.02 ± 0.16 mg/dl and 25.16 ± 4.65U/ L respectively. We have found that there is a significant difference in the above said parameters among patients in different stages of CKD (stage 3-5 indicating the progression of mineral bone disease with advancing stage of CKD.

  12. Long term deactivation test of high dust SCR catalysts by straw co-firing

    Energy Technology Data Exchange (ETDEWEB)

    Weigang Lin; Degn Jensen, A.; Bjerkvig, J.

    2009-12-15

    The consequences of carbon dioxide induced global warming cause major concern worldwide. The consumption of energy produced with fossil fuels is the major factor that contributes to the global warming. Biomass is a renewable energy resource and has a nature of CO{sub 2} neutrality. Co-combustion of biomass in existing coal fired power plants can maintain high efficiency and reduce the emission of CO{sub 2} at same time. However, one of the problems faced by co-firing is deactivation of the SCR catalysts. Understanding of the mechanisms of deactivation of the catalyst elements at co-firing conditions is crucial for long term runs of the power plants. Twenty six SCR catalyst elements were exposed at two units (SSV3 and SSV4) in the Studstrup Power Plant for a long period. Both units co-fire coal and straw with a typical fraction of 8-10% straw on an energy basis during co-firing. SSV4 unit operated in co-firing mode most of the time; SSV3 unit co-fired straw half of the operating time. The main objective of this PSO-project is to gain knowledge of a long term influence on catalyst activity when co-firing straw in coal-fired power plants, thus, to improve the basis for operating the SCR-plants for NO{sub x}-reduction. The exposure time of the applied catalyst elements (HTAS and BASF) varied from approximately 5000 to 19000 hours in the power plant by exchanging the element two times. The activity of all elements was measured before and after exposure in a bench scale test rig at the Department of Chemical and Biochemical Engineering, Technical University of Denmark. The results show that the activity, estimated by exclusion of channel clogging of the elements, decreases gradually with the total exposure time. It appears that the exposure time under co-firing condition has little effect on the deactivation of the catalyst elements and no sharp decrease of the activity was observed. The average deactivation rate of the catalyst elements is 1.6 %/1000 hours. SEM

  13. Pre-operative renal volume predicts peak creatinine after congenital heart surgery in neonates.

    Science.gov (United States)

    Carmody, J Bryan; Seckeler, Michael D; Ballengee, Cortney R; Conaway, Mark; Jayakumar, K Anitha; Charlton, Jennifer R

    2014-10-01

    Acute kidney injury is common in neonates following surgery for congenital heart disease. We conducted a retrospective analysis to determine whether neonates with smaller pre-operative renal volume were more likely to develop post-operative acute kidney injury. We conducted a retrospective review of 72 neonates who underwent congenital heart surgery for any lesion other than patent ductus arteriosus at our institution from January 2007 to December 2011. Renal volume was calculated by ultrasound using the prolate ellipsoid formula. The presence and severity of post-operative acute kidney injury was determined both by measuring the peak serum creatinine in the first 7 days post-operatively and by using the Acute Kidney Injury Network scoring system. Using a linear change point model, a threshold renal volume of 17 cm³ was identified. Below this threshold, there was an inverse linear relationship between renal volume and peak post-operative creatinine for all patients (p = 0.036) and the subgroup with a single morphologic right ventricle (p = 0.046). There was a non-significant trend towards more acute kidney injury using Acute Kidney Injury Network criteria in all neonates with renal volume ≤17 cm³ (p = 0.11) and in the subgroup with a single morphologic right ventricle (p = 0.17). Pre-operative renal volume ≤17 cm³ is associated with a higher peak post-operative creatinine and potentially greater risk for post-operative acute kidney injury for neonates undergoing congenital heart surgery. Neonates with a single right ventricle may be at higher risk.

  14. Radioimmunological determination of digoxin in serum

    International Nuclear Information System (INIS)

    Gruber, G.; Sorger, D.

    1979-01-01

    The tested quality signs of the digoxin-RIA (Medica) correspond to other RIA-test methods. The digoxin-RIA (Medica) is, therefore, well suited for clinical examinations. In the dilanacin-(digoxin-) long-term therapy with the maintenance dose of 0.5 mg digoxin a day 75.4% of the patients examined (n = 65) were within the therapeutic field. In each case 12.3% were underdigitalised or overdigitalised, respectively. In the 8 patients in the toxic region only the half showed signs of digoxin intoxication. It is referred to the importance of creatinine and potassium in the serum, to the digoxin creatinene and potassium in the serum, to the digoxin clearance depending on age, to the body weight and the body surface, respectively, in very obese patients for the height of the serum digoxin level and for the compatibility of this heart glycoside. (author)

  15. Population Reference Values for Serum Methylmalonic Acid Concentrations and Its Relationship with Age, Sex, Race-Ethnicity, Supplement Use, Kidney Function and Serum Vitamin B12 in the Post-Folic Acid Fortification Period

    Directory of Open Access Journals (Sweden)

    Vijay Ganji

    2018-01-01

    Full Text Available Serum methylmalonic acid (MMA is elevated in vitamin B-12 deficiency and in kidney dysfunction. Population reference values for serum MMA concentrations in post-folic acid fortification period are lacking. Aims of this study were to report the population reference values for serum MMA and to evaluate the relation between serum MMA and sex, age, race-ethnicity, kidney dysfunction and vitamin B-12. We used data from three National Health and Nutrition Examination Surveys, 1999–2000, 2001–2002 and 2003–2004 conducted after folic acid fortification commenced (n = 18,569. Geometric mean MMA was ≈22.3% higher in non-Hispanic white compared to non-Hispanic black (141.2 vs. 115.5 nmol/L and was ≈62.7% higher in >70 years old persons compared to 21–30 years old persons (196.9 vs. 121.0 nmol/L. Median serum MMA was ≈28.5% higher in the 1st the quartile of serum vitamin B-12 than in the 4th quartile of serum vitamin B-12 and was ≈35.8% higher in the 4th quartile of serum creatinine than in the 1st quartile of serum creatinine. Multivariate-adjusted serum MMA concentration was significantly associated with race-ethnicity (p < 0.001 and age (p < 0.001 but not with sex (p = 0.057. In this large US population based study, serum MMA concentrations presented here reflect the post-folic acid fortification scenario. Serum MMA concentrations begin to rise at the age of 18–20 years and continue to rise afterwards. Age-related increase in serum MMA concentration is likely to be due to a concomitant decline in kidney function and vitamin B-12 status.

  16. An engineering approach to the design and construction of a small modular stellarator for magnetic confinement of plasma. SCR-1

    International Nuclear Information System (INIS)

    Barillas, Laura; Vargas, V. Iván; Alpízar, Asdrúval

    2011-01-01

    This paper briefly describes the design and construction of Stellarator of Costa Rica 1 (SCR-1) from an engineering perspective. SCR-1 is a small modular Stellarator for magnetic confinement of plasma developed by the Plasma Physics Group of the Instituto Tecnológico de Costa Rica (ITCR). The SCR-1 is based on the small Spanish Stellarator UST 1 (Ultra Small Torus 1), created by engineer Vicente Queral. Some of the characteristics of the SCR-1 are the following: it will be a 2-field period modular stellarator with an aspect ratio ≈ 6; low shear configuration with core and edge rotational transform equal to 0.32 and 0.28; it will employ stainless steel torus-shaped vacuum vessel which will hold a plasma with an average radius a ≈ 42.2 mm, a volume of 8 liters (0.008 m 3 ), and major radius R = 238 mm. This plasma will be confined by a magnetic field (B ≈ 90 mT) given by 12 modular coils with 12 turns each, carrying a current of 725 A per turn providing a total toroidal field (TF) current of 8.7 kA-turn per coil. The coils will be supplied by a bank of cell batteries of 120 V. Typical length of the plasma pulse will be between 4 s to 10 s. The plasma heating will be achieved by electron cyclotron radio-frequency (ECH) from two magnetrons providing a total power of 5 kW, at a frequency of 2.45 GHz corresponding to the first harmonic (B 0 = 87.8 mT). The expected electron temperature and density are 15 eV and 7x10 16 m -3 respectively. The initial diagnostics on the SCR-1 will consist of a Langmuir probe with a displacement system, a heterodyne microwave interferometer (frequency of 28 GHz, corresponding to a wavelength of λ = 10.71 mm). The first plasma of the SCR-1 is expected at the beginning of 2012. (author)

  17. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  18. Urinary orotic acid-to-creatinine ratios in cats with hepatic lipidosis.

    Science.gov (United States)

    VanSteenhouse, J L; Dimski, D S; Swenson, D H; Taboada, J

    1999-06-01

    To determine urinary orotic acid (OA) concentration and evaluate the urinary OA-to-creatinine ratio (OACR) in cats with hepatic lipidosis (HL). 20 cats with HL and 20 clinically normal cats. Hepatic lipidosis was diagnosed on the basis of clinical signs, results of serum biochemical analyses, exclusion of other concurrent illness, and cytologic or histologic evaluation of liver biopsy specimens. Urine samples were collected from each cat and frozen at -20 C until assayed. Urine creatinine concentrations were determined, using an alkaline picrate method followed by spectrophotometric assay. Urine OA concentration was determined, using high-performance liquid chromatography. Minimum amount of detectable OA in feline urine was 1 microg/ml. Because of small interfering peaks near the base of the OA peak, the minimum quantifiable concentration of OA was determined to be 5 microg/ml. Urinary OACR was compared in both groups of cats. Differences in urinary OACR were not detected between clinically normal cats and cats with HL. Peaks were not detected for urinary OA in any of the 20 clinically normal cats. Of the 20 HL cats, 14 did not have detectable peaks for urinary OA. Of the 6 HL cats that had detectable urinary OA peaks, 3 had values of <5 microg/ml. Apparently, OACR does not increase significantly in cats with HL. Urinary OACR is not a useful diagnostic test for HL in cats.

  19. LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers’ 24 Hour Urine

    Directory of Open Access Journals (Sweden)

    Hongwei Hou

    2012-01-01

    Full Text Available A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1×150 mm, 3.5 μm. The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v. Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R=0.942, P<0.0001. However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio.

  20. Nadir creatinine in posterior urethral valves: How high is low enough?

    Science.gov (United States)

    Coleman, R; King, T; Nicoara, C-D; Bader, M; McCarthy, L; Chandran, H; Parashar, K

    2015-12-01

    Large retrospective studies of people with posterior urethral valves (PUV) have reported chronic renal insufficiency (CRI) in up to one third of the participants and end-stage renal failure in up to one quarter of them. Nadir creatinine (lowest creatinine during the first year following diagnosis) is the recognised prognostic indicator for renal outcome in PUV, the most commonly used cut-off being 1 mg/dl (88.4 umol/l). To conduct a statistical analysis of nadir creatinine in PUV patients in order to identify the optimal cut-off level as a prognostic indicator for CRI. Patients treated by endoscopic valve ablation at the present institution between 1993 and 2004 were reviewed. Chronic renal insufficiency was defined as CKD2 or higher. Statistical methods included receiver operating characteristic (ROC) curve analysis, Fisher exact test and diagnostic utility tests. Statistical significance was defined as P creatinine was identified in 96 patients. The median follow-up was 9.4 (IQR 7.0, 13.4) years. A total of 29 (30.2%) patients developed CRI, with nine (9.4%) reaching end-stage renal failure. On ROC analysis, Nadir creatinine was highly prognostic for future CRI, with an Area Under the Curve of 0.887 (P creatinine >88.4 umol/l compared with 19 of 86 (22.2%) patients with lower nadir creatinine (P creatinine cut-off of 88.4 umol/l gave a specificity of 100%, but poor sensitivity of 34.5%. Lowering the cut-off to 75 umol/l resulted in improvement in all diagnostic utility tests (Table). All 14 (100%) patients with nadir creatinine >75 umol/l developed CRI, compared with 15 of 82 (18.3%) patients with lower nadir creatinine (P creatinine creatinine >75 umol/l (OR 48.988; CI 4.9-490.11) to be independent risk factors for progression to CRI. Using cut-off values of 35 umol/l and 75 umol/l, patients can be stratified into low-, intermediate- and high-risk groups, with development of CRI in 5.3%, 28.3% and 100%, respectively (P creatinine >75 umol/l (0.85

  1. Detection of urinary creatinine using gold nanoparticles after solid phase extraction

    Science.gov (United States)

    Sittiwong, Jarinya; Unob, Fuangfa

    2015-03-01

    Label-free gold nanoparticles (AuNPs) were utilized in the detection of creatinine in human urine after a sample preparation by extraction of creatinine on sulfonic acid functionalized silica gel. With the proposed sample preparation method, the interfering effects of the urine matrix on creatinine detection by AuNPs were eliminated. Parameters affecting creatinine extraction were investigated. The aggregation of AuNPs induced by creatinine resulted in a change in the surface plasmon resonance signal with a concomitant color change that could be observed by the naked eye and quantified spectrometrically. The effect of AuNP concentration and reaction time on AuNP aggregation was investigated. The method described herein provides a determination of creatinine in a range of 15-40 mg L-1 with a detection limit of 13.7 mg L-1 and it was successfully used in the detection of creatinine in human urine samples.

  2. Recovery from radiation induced changes in some protein end-products in the liver and blood serum of irradiated rats

    International Nuclear Information System (INIS)

    Elkashef, H.S.; Roushdy, H.M.; Saada, H.N.; Abdelsamie, M.A.

    1989-01-01

    When rats were subjected to whole body gamma-irradiation at the dose of 5.5 Gy it caused significant changes in the content of urea and creatine the serum at 7 and 14 days postirradiation. In the liver significant changes were observed in the content of urea, creatine and creatinine at all post-irradiation days except the third day for urea and seventh day for creatine. Ten days pre-irradiation of the rats a mixture of 5 mg testosterone propionate and 10 mg of vitamin E was intraperitoneally injected. The results indicated that this mixture could help in obtaining complete recovery for radiation induced changes in the content of urea in both liver and serum of irradiated protected rats. Also this mixture provided good protection and caused recovery from radiation induced changes in the liver creatine on the third and seventh days after irradiation. But for serum creatine, the recovery was observed only on the third post irradiation day. The applied radiation dose did not induce any significant changes in the level of serum creatinine, while a partial recovery was noticed for liver creatinine in irradiated protected rats. The recovery process seems to be related to the radiosensitivity of the animal tissue, with the chemical structure of the radioprotector substances and the estimated compounds as well as the post-irradiation time intervals.3 tab

  3. Clinical significance of serum and urinary HER2/neu protein levels in primary non-muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Ozgur Arikan

    2015-12-01

    Full Text Available Objective: We aimed to compare serum and urinary HER2/neu levels between healthy control group and patients with non-muscle invasive bladder cancer. Additionally, we evaluated relationship of HER2/neu levels with tumor stage, grade, recurrence and progression. Materials and Methods: Fourty-four patients with primary non-muscle invasive bladder tumors (Group 2 and 40 healthy control group (Group 1 were included the study. Blood and urinary samples were collected from all patients and HER2/neu levels were measured by ELISA method. Blood and urinary HER2/neu levels and additionally, ratio of urinary HER2/neu levels to urinary creatinine levels were recorded. Demographic data and tumor characteristics were recorded. Results: Mean serum HER2/neu levels were similar between two groups and statistically significant difference wasn't observed. Urinary HER2/neu levels were significantly higher in group 2 than group 1. Ratio of urinary HER2/neu to urinary creatinine was significantly higher in group 2 than group 1, (p=0,021. Serum and urinary HER2/ neu levels were not associated with tumor stage, grade, recurrence and progression while ratio of urinary HER2/neu to urinary creatinin levels were significantly higher in high-grade tumors. HER2/neu, the sensitivity of the test was found to be 20.5%, and the specificity was 97.5%, also for the urinary HER2/neu/urinary creatinine ratio, the sensitivity and specificity of the test were found to be 31.8% and 87.5%, respectively. Conclusions: Urinary HER2/neu and ratio of urinary creatinine urine were significantly higher in patients with bladder cancer compared to healthy subjects. Large series and controlled studies are needed for use as a tumor marker.

  4. Underestimation of urinary albumin to creatinine ratio in morbidly obese subjects due to high urinary creatinine excretion.

    Science.gov (United States)

    Guidone, Caterina; Gniuli, Donatella; Castagneto-Gissey, Lidia; Leccesi, Laura; Arrighi, Eugenio; Iaconelli, Amerigo; Mingrone, Geltrude

    2012-04-01

    Albuminuria, a chronic kidney and/or cardiovascular disease biomarker, is currently measured as albumin-to-creatinine ratio (ACR). We hypothesize that in severely obese individuals ACR might be abnormally low in spite of relatively high levels of urinary albumin due to increased creatininuria. One-hundred-eighty-four subjects were divided into tertiles based on their BMI. Fat-free mass (FFM) and fat-mass were assessed by DEXA; 24-h creatinine and albumin excretion, ACR, lipid profile and blood pressure were measured. Twenty-four-hour creatinine highly correlated (R = 0.75) with FFM. Since both creatininuria and albuminuria increased with the BMI, being the increase in creatininuria preponderant in subjects with BMI>35, their ratio (AC-ratio) did not change significantly from that of subjects in the lower BMI tertile. ACR only correlated with the systolic blood pressure, while both albuminuria and cretininuria correlated (P = 0.01) with the absolute 10-year CHD risk. In subjects with BMI>35, 100 mg of albumin excreted with urine increased the CHD risk of 2%. Albumin-to-creatinine ratio is underestimated in severely obese individuals as a consequence of the large creatininuria, which is proportional to the increased FFM. Therefore, at least in this population 24-h albuminuria should be more reliable than ACR. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  5. A method of formal requirements analysis for NPP I and C systems based on object-oriented visual modeling with SCR

    International Nuclear Information System (INIS)

    Koo, S. R.; Seong, P. H.

    1999-01-01

    In this work, a formal requirements analysis method for Nuclear Power Plant (NPP) I and C systems is suggested. This method uses Unified Modeling Language (UML) for modeling systems visually and Software Cost Reduction (SCR) formalism for checking the system models. Since object-oriented method can analyze a document by the objects in a real system, UML models that use object-oriented method are useful for understanding problems and communicating with everyone involved in the project. In order to analyze the requirement more formally, SCR tabular notations is converted from UML models. To help flow-through from UML models to SCR specifications, additional syntactic extensions for UML notation and a converting procedure are defined. The combined method has been applied to Dynamic Safety System (DSS). From this application, three kinds of errors were detected in the existing DSS requirements

  6. Pulmonary Catherization Data Correlate Poorly with Renal Function in Heart Failure.

    Science.gov (United States)

    Masha, Luke; Stone, James; Stone, Danielle; Zhang, Jun; Sheng, Luo

    2018-04-10

    The mechanisms of renal dysfunction in heart failure are poorly understood. We chose to explore the relationship of cardiac filling pressures and cardiac index (CI) in relation to renal dysfunction in advanced heart failure. To determine the relationship between renal function and cardiac filling pressures using the United Network of Organ Sharing (UNOS) pulmonary artery catherization registry. Patients over the age of 18 years who were listed for single-organ heart transplantation were included. Exclusion criteria included a history of mechanical circulatory support, previous transplantation, any use of renal replacement therapy, prior history of malignancy, and cardiac surgery, amongst others. Correlations between serum creatinine (SCr) and CI, pulmonary capillary wedge pressure (PCWP), pulmonary artery systolic pressure (PASP), and pulmonary artery diastolic pressure (PADP) were assessed by Pearson correlation coefficients and simple linear regression coefficients. Pearson correlation coefficients between SCr and PCWP, PASP, and PADP were near zero with values of 0.1, 0.07, and 0.08, respectively (p < 0.0001). A weak negative correlation coefficient between SCr and CI was found (correlation coefficient, -0.045, p = 0.027). In a subgroup of young patients unlikely to have noncardiac etiologies, no significant correlations between these values were identified. These findings suggest that, as assessed by pulmonary artery catherization, none of the factors - PCWP, PASP, PADP, or CI - play a prominent role in cardiorenal syndromes. © 2018 S. Karger AG, Basel.

  7. FTIR in situ mechanistic study of the NH3-NO/NO2 "Fast SCR" reaction over a commercial Fe-ZSM-5 catalyst

    Czech Academy of Sciences Publication Activity Database

    Ruggeri, M. P.; Grossale, A.; Nova, I.; Tronconi, E.; Jirglová, Hana; Sobalík, Zdeněk

    2012-01-01

    Roč. 184, č. 1 (2012), s. 107-114 ISSN 0920-5861 R&D Projects: GA AV ČR KAN100400702; GA ČR GA203/09/1627 Institutional research plan: CEZ:AV0Z40400503 Keywords : urea /NH3 SCR * fast SCR * NO2 adsorption Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.980, year: 2012

  8. Iodine and creatinine testing in urine dried on filter paper

    Energy Technology Data Exchange (ETDEWEB)

    Zava, Theodore T., E-mail: ttzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Kapur, Sonia, E-mail: soniak@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Zava, David T., E-mail: dzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States)

    2013-02-18

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R{sup 2} = 0.9483; creatinine: R{sup 2} = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs.

  9. Iodine and creatinine testing in urine dried on filter paper

    International Nuclear Information System (INIS)

    Zava, Theodore T.; Kapur, Sonia; Zava, David T.

    2013-01-01

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R 2 = 0.9483; creatinine: R 2 = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs

  10. SCR activity of conformed CuOx/ZrO2-SO4 catalysts

    DEFF Research Database (Denmark)

    Rasmussen, Søren Birk; Yates, Malcolm; Due-Hansen, Johannes

    2010-01-01

    CuOX/ZrO2-SO4 catalysts have been synthesised as conformed materials with the use of sepiolite as agglomerant and the performance in the NH3-SCR reaction with relation to biomass fired boiler units have been studied. The optimal Cu-loading of the catalysts is 3 wt.% CuO, both in terms of activity...

  11. Bmi-1 plays a critical role in the protection from acute tubular necrosis by mobilizing renal stem/progenitor cells.

    Science.gov (United States)

    Lv, Xianhui; Yu, Zhenzhen; Xie, Chunfeng; Dai, Xiuliang; Li, Qing; Miao, Dengshun; Jin, Jianliang

    2017-01-22

    The regeneration of injured tubular cell occurs primarily from intrinsic renal stem/progenitor cells (RSCs) labeled with CD24 and CD133 after acute tubular necrosis (ATN). Bmi-1 plays a crucial role in regulating self-renewal, differentiation and aging of multiple adult stem cells and progenitor cells. Bmi-1 was rapidly elevated in the induction of adult kidney regeneration by renal injury. To determine whether Bmi-1 maintained mobilization of RSCs in the protection from ATN, glycerol-rhabdomyolysis-induced ATN were performed in wild type (WT) and Bmi-1-deficient (Bmi-1 -/- ) mice. Their ATN phenotypes were analyzed; CD24 and CD133 double positive (CD24 + CD133 + ) cells were measured; and the levels of serum urea nitrogen (SUN) and serum creatinine (SCr) were detected. We found that CD24 + CD133 + RSCs were mobilized in WT ATN mice with the increased expression of Bmi-1; Bmi-1 deficiency led to increased tubular cast formation and necrosis, elevated levels of SUN and SCr, decreased tubular proliferation, and immobilized ratio of RSCs in ATN. These findings indicated that Bmi-1 played a critical role in the protection from ATN by maintaining mobilization of RSCs and would be a novel therapeutic target for preventing the progression of ATN. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  13. Adherence to guidelines for creatinine and potassium monitoring and discontinuation following renin-angiotensin system blockade: a UK general practice-based cohort study.

    Science.gov (United States)

    Schmidt, Morten; Mansfield, Kathryn E; Bhaskaran, Krishnan; Nitsch, Dorothea; Sørensen, Henrik Toft; Smeeth, Liam; Tomlinson, Laurie A

    2017-01-09

    To examine adherence to serum creatinine and potassium monitoring and discontinuation guidelines following initiation of treatment with ACE inhibitors (ACEI) or angiotensin receptor blockers (ARBs); and whether high-risk patients are monitored. A general practice-based cohort study using electronic health records from the UK Clinical Practice Research Datalink and Hospital Episode Statistics. UK primary care, 2004-2014. 223 814 new ACEI/ARB users. Proportion of patients with renal function monitoring before and after ACEI/ARB initiation; creatinine increase ≥30% or potassium levels >6 mmol/L at first follow-up monitoring; and treatment discontinuation after such changes. Using logistic regression models, we also examined patient characteristics associated with these biochemical changes, and with follow-up monitoring within the guideline recommendation of 2 weeks after treatment initiation. 10% of patients had neither baseline nor follow-up monitoring of creatinine within 12 months before and 2 months after initiation of an ACEI/ARB, 28% had monitoring only at baseline, 15% only at follow-up, and 47% both at baseline and follow-up. The median period between the most recent baseline monitoring and drug initiation was 40 days (IQR 12-125 days). 34% of patients had baseline creatinine monitoring within 1 month before initiating therapy, but creatinine increase ≥30% (n=567, 1.2%) or potassium level >6 mmol/L (n=191, 0.4%), 80% continued treatment. Although patients with prior myocardial infarction, hypertension or baseline potassium >5 mmol/L were at high risk of ≥30% increase in creatinine after ACEI/ARB initiation, there was no evidence that they were more frequently monitored. Only one-tenth of patients initiating ACEI/ARB therapy receive the guideline-recommended creatinine monitoring. Moreover, the vast majority of the patients fulfilling postinitiation discontinuation criteria for creatinine and potassium increases continue on treatment

  14. Adherence to guidelines for creatinine and potassium monitoring and discontinuation following renin–angiotensin system blockade: a UK general practice-based cohort study

    Science.gov (United States)

    Schmidt, Morten; Bhaskaran, Krishnan; Nitsch, Dorothea; Sørensen, Henrik Toft; Smeeth, Liam; Tomlinson, Laurie A

    2017-01-01

    Objectives To examine adherence to serum creatinine and potassium monitoring and discontinuation guidelines following initiation of treatment with ACE inhibitors (ACEI) or angiotensin receptor blockers (ARBs); and whether high-risk patients are monitored. Design A general practice-based cohort study using electronic health records from the UK Clinical Practice Research Datalink and Hospital Episode Statistics. Setting UK primary care, 2004–2014. Subjects 223 814 new ACEI/ARB users. Main outcome measures Proportion of patients with renal function monitoring before and after ACEI/ARB initiation; creatinine increase ≥30% or potassium levels >6 mmol/L at first follow-up monitoring; and treatment discontinuation after such changes. Using logistic regression models, we also examined patient characteristics associated with these biochemical changes, and with follow-up monitoring within the guideline recommendation of 2 weeks after treatment initiation. Results 10% of patients had neither baseline nor follow-up monitoring of creatinine within 12 months before and 2 months after initiation of an ACEI/ARB, 28% had monitoring only at baseline, 15% only at follow-up, and 47% both at baseline and follow-up. The median period between the most recent baseline monitoring and drug initiation was 40 days (IQR 12–125 days). 34% of patients had baseline creatinine monitoring within 1 month before initiating therapy, but creatinine increase ≥30% (n=567, 1.2%) or potassium level >6 mmol/L (n=191, 0.4%), 80% continued treatment. Although patients with prior myocardial infarction, hypertension or baseline potassium >5 mmol/L were at high risk of ≥30% increase in creatinine after ACEI/ARB initiation, there was no evidence that they were more frequently monitored. Conclusions Only one-tenth of patients initiating ACEI/ARB therapy receive the guideline-recommended creatinine monitoring. Moreover, the vast majority of the patients fulfilling postinitiation

  15. Gaseous emissions from a heavy-duty engine equipped with SCR aftertreatment system and fuelled with diesel and biodiesel: Assessment of pollutant dispersion and health risk

    Energy Technology Data Exchange (ETDEWEB)

    Tadano, Yara S.; Borillo, Guilherme C.; Godoi, Ana Flávia L.; Cichon, Amanda; Silva, Thiago O.B.; Valebona, Fábio B.; Errera, Marcelo R. [Environmental Engineering Department, Federal University of Parana, 210 Francisco H. dos Santos St., Curitiba, PR, 81531-980 Brazil (Brazil); Penteado Neto, Renato A.; Rempel, Dennis; Martin, Lucas [Institute of Technology for Development, Lactec–Leme Division, 01 LothárioMeissner Ave., Curitiba, PR, 80210-170 (Brazil); Yamamoto, Carlos I. [Chemical Engineering Department, Federal University of Parana, 210 Francisco H. dos Santos St., Curitiba, PR, 81531-980 Brazil (Brazil); Godoi, Ricardo H.M., E-mail: rhmgodoi@ufpr.br [Environmental Engineering Department, Federal University of Parana, 210 Francisco H. dos Santos St., Curitiba, PR, 81531-980 Brazil (Brazil)

    2014-12-01

    The changes in the composition of fuels in combination with selective catalytic reduction (SCR) emission control systems bring new insights into the emission of gaseous and particulate pollutants. The major goal of our study was to quantify NO{sub x}, NO, NO{sub 2}, NH{sub 3} and N{sub 2}O emissions from a four-cylinder diesel engine operated with diesel and a blend of 20% soybean biodiesel. Exhaust fume samples were collected from bench dynamometer tests using a heavy-duty diesel engine equipped with SCR. The target gases were quantified by means of Fourier transform infrared spectrometry (FTIR). The use of biodiesel blend presented lower concentrations in the exhaust fumes than using ultra-low sulfur diesel. NO{sub x} and NO concentrations were 68% to 93% lower in all experiments using SCR, when compared to no exhaust aftertreatment. All fuels increased NH{sub 3} and N{sub 2}O emission due to SCR, a precursor secondary aerosol, and major greenhouse gas, respectively. An AERMOD dispersion model analysis was performed on each compound results for the City of Curitiba, assumed to have a bus fleet equipped with diesel engines and SCR system, in winter and summer seasons. The health risks of the target gases were assessed using the Risk Assessment Information System For 1-h exposure of NH{sub 3}, considering the use of low sulfur diesel in buses equipped with SCR, the results indicated low risk to develop a chronic non-cancer disease. The NO{sub x} and NO emissions were the lowest when SCR was used; however, it yielded the highest NH{sub 3} concentration. The current results have paramount importance, mainly for countries that have not yet adopted the Euro V emission standards like China, India, Australia, or Russia, as well as those already adopting it. These findings are equally important for government agencies to alert the need of improvements in aftertreatment technologies to reduce pollutants emissions. - Highlights: • Emission, dispersion and risk assessment

  16. Nitrite-induced acute kidney injury with secondary hyperparathyroidism: Case report and literature review.

    Science.gov (United States)

    Peng, Tao; Hu, Zhao; Yang, Xiangdong; Gao, Yanxia; Ma, Chengjun

    2018-02-01

    Acute kidney injury (AKI) with hyperparathyroidism caused by nitrite was rare, and renal function and parathyroid hormone (PTH) decreased to normal range after therapy. Acute kidney injury was diagnosed in a 40-year-old male with hyperparathyroidism and cyanosis of his hands and both forearms. The patient ate some recently pickled vegetables, and he experienced nausea, vomiting and diarrhoea without oliguria or anuria; Additionally, his hands and both forearms had a typical blue ash appearance. After admission, the laboratory findings indicated theincreasing serum creatinine (Scr) and parathyroid hormone (PTH). He was diagnosed as acute kidney injury with hyperparathyroidism caused by nitrite. The patient stopped eating the pickled vegetables and was given rehydration, added calories and other supportive therapy without any glucocorticoids. According to his clinical manifestations, laboratory findings and imaging results, the patient was diagnosed with acute kidney injury with secondary hyperparathyroidism. He was given symptomatic supportive care therapy. After one week, the serum creatinine, parathyroid hormone (PTH), hypercalcemia, hyperphosphatemia, proteinuria, and urine red blood cell values decreased to normal range. Nitrite-induced acute kidney injury with secondary hyperparathyroidism was relatively rare. After therapy, the function of the kidney and parathyroid returned to normal. This case suggests that detailed collection of medical history, physical examination and correct symptomatic treatment is very important.

  17. Experimental study on the particulate matter and nitrogenous compounds from diesel engine retrofitted with DOC+CDPF+SCR

    Science.gov (United States)

    Zhang, Yunhua; Lou, Diming; Tan, Piqiang; Hu, Zhiyuan

    2018-03-01

    The increasingly stringent emission regulations will mandate the retrofit of after-treatment devices for in-use diesel vehicles, in order to reduce their substantial particulate matter and nitrogen oxides (NOX) emissions. In this paper, a combination of DOC (diesel oxidation catalyst), CDPF (catalytic diesel particulate filter) and SCR (selective catalytic reduction) retrofit for a heavy-duty diesel engine was employed to perform experiment on the engine test bench to evaluate the effects on the particulate matter emissions including particle number (PN), particle mass (PM), particle size distributions and nitrogenous compounds emissions including NOX, nitrogen dioxide (NO2)/NOX, nitrous oxide (N2O) and ammonia (NH3) slip. In addition, the urea injection was also of our concern. The results showed that the DOC+CDPF+SCR retrofit almost had no adverse effect on the engine power and fuel consumption. Under the test loads, the upstream DOC and CDPF reduced the PN and PM by an average of 91.6% and 90.9%, respectively. While the downstream SCR brought about an average decrease of 85% NOX. Both PM and NOX emission factors based on this retrofit were lower than China-Ⅳ limits (ESC), and even lower than China-Ⅴ limits (ESC) at medium and high loads. The DOC and CDPF changed the particle size distributions, leading to the increase in the proportion of accumulation mode particles and the decrease in the percentage of nuclear mode particles. This indicates that the effect of DOC and CDPF on nuclear mode particles was better than that of accumulation mode ones. The upstream DOC could increase the NO2/NOX ratio to 40%, higher NO2/NOX ratio improved the efficiency of CDPF and SCR. Besides, the N2O emission increased by an average of 2.58 times after the retrofit and NH3 slip occurred with the average of 26.7 ppm. The rate of urea injection was roughly equal to 8% of the fuel consumption rate. The DOC+CDPF+SCR retrofit was proved a feasible and effective measurement in terms

  18. No Impact of the Analytical Method Used for Determining Cystatin C on Estimating Glomerular Filtration Rate in Children.

    Science.gov (United States)

    Alberer, Martin; Hoefele, Julia; Benz, Marcus R; Bökenkamp, Arend; Weber, Lutz T

    2017-01-01

    Measurement of inulin clearance is considered to be the gold standard for determining kidney function in children, but this method is time consuming and expensive. The glomerular filtration rate (GFR) is on the other hand easier to calculate by using various creatinine- and/or cystatin C (Cys C)-based formulas. However, for the determination of serum creatinine (Scr) and Cys C, different and non-interchangeable analytical methods exist. Given the fact that different analytical methods for the determination of creatinine and Cys C were used in order to validate existing GFR formulas, clinicians should be aware of the type used in their local laboratory. In this study, we compared GFR results calculated on the basis of different GFR formulas and either used Scr and Cys C values as determined by the analytical method originally employed for validation or values obtained by an alternative analytical method to evaluate any possible effects on the performance. Cys C values determined by means of an immunoturbidimetric assay were used for calculating the GFR using equations in which this analytical method had originally been used for validation. Additionally, these same values were then used in other GFR formulas that had originally been validated using a nephelometric immunoassay for determining Cys C. The effect of using either the compatible or the possibly incompatible analytical method for determining Cys C in the calculation of GFR was assessed in comparison with the GFR measured by creatinine clearance (CrCl). Unexpectedly, using GFR equations that employed Cys C values derived from a possibly incompatible analytical method did not result in a significant difference concerning the classification of patients as having normal or reduced GFR compared to the classification obtained on the basis of CrCl. Sensitivity and specificity were adequate. On the other hand, formulas using Cys C values derived from a compatible analytical method partly showed insufficient

  19. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    Science.gov (United States)

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  20. Abnormal glomerular filtration rate in children, adolescents and young adults starts below 75 mL/min/1.73 m(2).

    Science.gov (United States)

    Pottel, Hans; Hoste, Liesbeth; Delanaye, Pierre

    2015-05-01

    The chronic kidney disease (CKD) classification system for children is similar to that for adults, with both mainly based on estimated glomerular filtration rate (eGFR) combined with fixed cut-off values. The main cut-off eGFR value used to define CKD is 60 mL/min/1.73 m(2), a value that is also applied for children older than 2 years of age, adolescents and young adults. Based on a literature search, we evaluated inclusion criteria for eGFR in clinical trials or research studies on CKD for children. We also collected information on direct measurements of GFR (mGFR) in children and adolescents, with the aim to estimate the normal reference range for GFR. Using serum creatinine (Scr) normal reference values and Scr-based eGFR-equations, we also evaluated the correspondence between Scr normal reference values and (e)GFR normal reference values. Based on our literature search, the inclusion of children in published CKD studies has been based on cut-off values for eGFR of >60 mL/min/1.73 m(2). The lower reference limits for mGFR far exceed this adult threshold. Using eGFR values calculated using Scr-based formulas, we found that abnormal Scr levels in children already correspond to eGFR values that are below a cut-off of 75 mL/min/1.73 m(2). Abnormal GFR in children, adolescents and young adults starts below 75 mL/min/1.73 m(2), and as abnormality is a sign of disease, we recommend referring children, adolescents and young adults with an (e)GFR of <75 mL/min/1.73 m(2) for further clinical assessment.

  1. Effect of perioperative sodium bicarbonate administration on renal function following cardiac surgery for infective endocarditis: a randomized, placebo-controlled trial.

    Science.gov (United States)

    Cho, Jin Sun; Soh, Sarah; Shim, Jae-Kwang; Kang, Sanghwa; Choi, Haegi; Kwak, Young-Lan

    2017-01-05

    Patients with infective endocarditis (IE) have an elevated risk of renal dysfunction because of extensive systemic inflammation and use of nephrotoxic antibiotics. In this randomized, placebo-controlled trial, we investigated whether perioperative sodium bicarbonate administration could attenuate postoperative renal dysfunction in patients with IE undergoing cardiac surgery. Seventy patients randomly received sodium chloride (n = 35) or sodium bicarbonate (n = 35). Sodium bicarbonate was administered as a 0.5 mmol/kg loading dose for 1 h commencing with anesthetic induction, followed by a 0.15 mmol/kg/h infusion for 23 h. The primary outcome was peak serum creatinine (SCr) level during the first 48 h postoperatively. The incidence of acute kidney injury, SCr level, estimated glomerular filtration rate, and major morbidity endpoints were assessed postoperatively. The peak SCr during the first 48 h postoperatively (bicarbonate vs. 1.01 (0.74, 1.37) mg/dl vs. 0.88 (0.76, 1.27) mg/dl, P = 0.474) and the incidence of acute kidney injury (bicarbonate vs. 29% vs. 23%, P = 0.584) were similar in both groups. The postoperative increase in SCr above baseline was greater in the bicarbonate group than in the control group on postoperative day 2 (0.21 (0.07, 0.33) mg/dl vs. 0.06 (0.00, 0.23) mg/dl, P = 0.028) and postoperative day 5 (0.23 (0.08, 0.36) mg/dl vs. 0.06 (0.00, 0.23) mg/dl, P = 0.017). Perioperative sodium bicarbonate administration had no favorable impact on postoperative renal function and outcomes in patients with IE undergoing cardiac surgery. Instead, it was associated with possibly harmful renal effects, illustrated by a greater increase in SCr postoperatively, compared to control. ClinicalTrials.gov, NCT01920126 . Registered on 31 July 2013.

  2. Gold nanoparticles-based colorimetric and visual creatinine assay

    International Nuclear Information System (INIS)

    He, Yi; Zhang, Xianhui; Yu, Haili

    2015-01-01

    We demonstrate a selective and sensitive method for determination of creatinine using citrate-stabilized gold nanoparticles (AuNPs) as a colorimetric probe. It is based on a direct cross-linking reaction that occurs between creatinine and AuNPs that causes aggregation of AuNPs and results in a color change from wine red to blue. The absorption peak is shifted from 520 to 670 nm. Under the optimized conditions, the shift in the absorption peak is related the logarithm of the creatinine concentration in the 0.1 to 20 mM range, and the instrumental detection limit (LOD) is 80 μM. This LOD is about one order of magnitude better than that that of the Jaffé method (720 μM). The assay displays good selectivity over interfering substances including various inorganic ions, organic small compounds, proteins, and biothiols. It was successfully employed to the determination of creatinine in spiked human urine. (author)

  3. 17-Year-Old Boy with Renal Failure and the Highest Reported Creatinine in Pediatric Literature

    Directory of Open Access Journals (Sweden)

    Vimal Master Sankar Raj

    2015-01-01

    Full Text Available The prevalence of chronic kidney disease (CKD is on the rise and constitutes a major health burden across the world. Clinical presentations in early CKD are usually subtle. Awareness of the risk factors for CKD is important for early diagnosis and treatment to slow the progression of disease. We present a case report of a 17-year-old African American male who presented in a life threatening hypertensive emergency with renal failure and the highest reported serum creatinine in a pediatric patient. A brief discussion on CKD criteria, complications, and potential red flags for screening strategies is provided.

  4. Simultaneous removal of NO and Hg{sup 0} over Ce-Cu modified V{sub 2}O{sub 5}/TiO{sub 2} based commercial SCR catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Guilong [School of Energy & Environmental Engineering, Hebei University of Technology, Tianjin 300401 (China); College of Environmental Science & Engineering, Nankai University, Tianjin 300350 (China); Shen, Boxiong, E-mail: shenbx@nankai.edu.cn [School of Energy & Environmental Engineering, Hebei University of Technology, Tianjin 300401 (China); Yu, Ranran [School of Energy & Environmental Engineering, Hebei University of Technology, Tianjin 300401 (China); He, Chuan; Zhang, Xiao [College of Environmental Science & Engineering, Nankai University, Tianjin 300350 (China)

    2017-05-15

    Highlights: • Simultaneous removal of NO and Hg{sup 0} over the novel modified commercial SCR catalysts. • 7% Ce-1% Cu/SCR catalyst exhibited excellent activity of NO conversion and Hg{sup 0} oxidation. • 7% Ce-1% Cu/SCR catalyst showed higher resistance to SO{sub 2} and H{sub 2}O than other catalysts. • The synergistic interaction between Ce and Cu in the catalyst improved the activity greatly. - Abstract: A series of novel Ce-Cu modified V{sub 2}O{sub 5}/TiO{sub 2} based commercial SCR catalysts were prepared via ultrasonic-assisted impregnation method for simultaneous removal of NO and elemental mercury (Hg{sup 0}). Nitrogen adsorption, X-ray diffraction (XRD), temperature programmed reduction of H{sub 2} (H{sub 2}-TPR) and X-ray photoelectron spectroscopy (XPS) were used to characterize the catalysts. 7% Ce-1% Cu/SCR catalyst exhibited the highest NO conversion efficiency (>97%) at 200–400 °C, as well as the best Hg{sup 0} oxidation activity (>75%) at 150–350 °C among all the catalysts. The XPS and H{sub 2}-TPR results indicated that 7% Ce-1% Cu/SCR possess abundant chemisorbed oxygen and good redox ability, which was due to the strong synergy between Ce and Cu in the catalyst. The existence of the redox cycle of Ce{sup 4+} + Cu{sup 1+} ↔ Ce{sup 3+} + Cu{sup 2+} could greatly improve the catalytic activity. 7% Ce-1% Cu/SCR showed higher resistance to SO{sub 2} and H{sub 2}O than other catalysts. NO has a promoting effect on Hg{sup 0} oxidation. The Hg{sup 0} oxidation activity was inhibited by the injection of NH{sub 3}, which was due to the competitive adsorption and oxidized mercury could be reduced by ammonia at temperatures greater than 325 °C. Therefore, Hg{sup 0} oxidation could easily occurred at the outlet of SCR catalyst layer due to the consumption of NH{sub 3}.

  5. The effect of acyclovir on the tubular secretion of creatinine in vitro

    Directory of Open Access Journals (Sweden)

    Aleksa Katarina

    2010-12-01

    Full Text Available Abstract Background While generally well tolerated, severe nephrotoxicity has been observed in some children receiving acyclovir. A pronounced elevation in plasma creatinine in the absence of other clinical manifestations of overt nephrotoxicity has been frequently documented. Several drugs have been shown to increase plasma creatinine by inhibiting its renal tubular secretion rather than by decreasing glomerular filtration rate (GFR. Creatinine and acyclovir may be transported by similar tubular transport mechanisms, thus, it is plausible that in some cases, the observed increase in plasma creatinine may be partially due to inhibition of tubular secretion of creatinine, and not solely due to decreased GFR. Our objective was to determine whether acyclovir inhibits the tubular secretion of creatinine. Methods Porcine (LLC-PK1 and human (HK-2 renal proximal tubular cell monolayers cultured on microporous membrane filters were exposed to [2-14C] creatinine (5 μM in the absence or presence of quinidine (1E+03 μM, cimetidine (1E+03 μM or acyclovir (22 - 89 μM in incubation medium. Results Results illustrated that in evident contrast to quinidine, acyclovir did not inhibit creatinine transport in LLC-PK1 and HK-2 cell monolayers. Conclusions The results suggest that acyclovir does not affect the renal tubular handling of creatinine, and hence, the pronounced, transient increase in plasma creatinine is due to decreased GFR, and not to a spurious increase in plasma creatinine.

  6. Weights, hematology and serum chemistry of free-ranging brown boobies (Sula leucogaster) in Johnston Atoll, Central Pacific

    Science.gov (United States)

    Work, Thierry M.

    1999-01-01

    Hematologic and serum chemistry values are reported for 105 brown boobies (Sula leucogaster) from Johnston Atoll, Central Pacific. Hematocrit, estimated total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase, and creatinine phosphokinase were analyzed. Hematologic and serum chemistry values varied with age and sex. Values were compared with those of red-footed boobies and other tropical and temperate marine pelecaniforms.

  7. End-Stage Renal Disease Outcomes among the Kaiser Permanente Southern California Creatinine Safety Program (Creatinine SureNet): Opportunities to Reflect and Improve.

    Science.gov (United States)

    Sim, John J; Batech, Michael; Danforth, Kim N; Rutkowski, Mark P; Jacobsen, Steven J; Kanter, Michael H

    2017-01-01

    The Kaiser Permanente Southern California (KPSC) creatinine safety program (Creatinine SureNet) identifies and outreaches to thousands of people annually who may have had a missed diagnosis for chronic kidney disease (CKD). We sought to determine the value of this outpatient program and evaluate opportunities for improvement. Longitudinal cohort study (February 2010 through December 2015) of KPSC members captured into the creatinine safety program who were characterized using demographics, laboratory results, and different estimations of glomerular filtration rate. Age- and sex-adjusted rates of end-stage renal disease (ESRD) were compared with those in the overall KPSC population. Among 12,394 individuals, 83 (0.7%) reached ESRD. The age- and sex-adjusted relative risk of ESRD was 2.7 times higher compared with the KPSC general population during the same period (94.7 vs 35.4 per 100,000 person-years; p creatinine measurements, only 13% had a urine study performed (32% among patients with confirmed CKD). Our study found a higher incidence of ESRD among individuals captured into the KPSC creatinine safety program. If the Chronic Kidney Disease Epidemiology Collaboration equation were used, fewer people would have been captured while improving the accuracy for diagnosing CKD. Urine testing was low even among patients with confirmed CKD. Our findings demonstrate the importance of a creatinine safety net program in an integrated health system but also suggest opportunities to improve CKD care and screening.

  8. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    Science.gov (United States)

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  9. Synthesis of FBD-based PLC design from NuSCR formal specification

    International Nuclear Information System (INIS)

    Yoo, Junbeom; Cha, Sungdeok; Kim, Chang Hwoi; Song, Duck Yong

    2005-01-01

    NuSCR is a formal specification language to document requirements for real-time embedded software with nuclear engineering applications in mind. Domain experts actively participated in selecting how to best represent various aspects. It uses tabular notations to specify required computations and automata to document state- or time-dependent behavior. As programmable logic controllers (PLCs) are widely used to implement real-time embedded software, synthesis of PLC code from a formal specification is desirable if transformation rules can be rigorously defined. In addition to improved productivity, results of safety analysis performed on requirements remain valid. In this paper, we demonstrate how NuSCR specification can be translated into semantically equivalent function block diagram (FBD) code. The process, except the initial phase where user provides information on missing or implicit details, is automated. Since executable code can be automatically generated using CASE tools from FBD, much of software development is automated. Proposed technique is currently being used in developing reactor protection system (RPS) for nuclear power plants in Korea, and experience to date has been positive. We demonstrate the proposed approach using the fixed set-point rising trip which is one of the most complex trip logics included in the RPS

  10. Oxidation of elemental mercury by modified spent TiO2-based SCR-DeNOx catalysts in simulated coal-fired flue gas.

    Science.gov (United States)

    Zhao, Lingkui; Li, Caiting; Zhang, Xunan; Zeng, Guangming; Zhang, Jie; Xie, Yin'e

    2016-01-01

    In order to reduce the costs, the recycle of spent TiO2-based SCR-DeNOx catalysts were employed as a potential catalytic support material for elemental mercury (Hg(0)) oxidation in simulated coal-fired flue gas. The catalytic mechanism for simultaneous removal of Hg(0) and NO was also investigated. The catalysts were characterized by Brunauer-Emmett-Teller (BET), scanning electron microscope (SEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) method. Results indicated that spent TiO2-based SCR-DeNOx catalyst supported Ce-Mn mixed oxides catalyst (CeMn/SCR1) was highly active for Hg(0) oxidation at low temperatures. The Ce1.00Mn/SCR1 performed the best catalytic activities, and approximately 92.80% mercury oxidation efficiency was obtained at 150 °C. The inhibition effect of NH3 on Hg(0) oxidation was confirmed in that NH3 consumed the surface oxygen. Moreover, H2O inhibited Hg(0) oxidation while SO2 had a promotional effect with the aid of O2. The XPS results illustrated that the surface oxygen was responsible for Hg(0) oxidation and NO conversion. Besides, the Hg(0) oxidation and NO conversion were thought to be aided by synergistic effect between the manganese and cerium oxides.

  11. Load-Independent Harmonic Mitigation in SCR-Fed Three-Phase Multiple Adjustable Speed Drive Systems with Deliberately Dispatched Firing Angles

    DEFF Research Database (Denmark)

    Yang, Yongheng; Davari, Pooya; Blaabjerg, Frede

    2018-01-01

    Adjustable speed drives (ASD) are widely used in industry for energy savings, where low-cost diode rectifiers are still employed as the front-ends, also for simplicity in control and reliability in operation. However, significant harmonics appear at the grid, which should be tackled according...... a harmonic mitigation strategy for multiple ASD systems, where silicon-controlled rectifiers (SCR) with boost converters in the dc-link have been adopted to increase the harmonic-current controllability. More specific, the SCR firing angles are deliberately dispatched among the drive units, which results...

  12. Back-calculating baseline creatinine overestimates prevalence of acute kidney injury with poor sensitivity.

    Science.gov (United States)

    Kork, F; Balzer, F; Krannich, A; Bernardi, M H; Eltzschig, H K; Jankowski, J; Spies, C

    2017-03-01

    Acute kidney injury (AKI) is diagnosed by a 50% increase in creatinine. For patients without a baseline creatinine measurement, guidelines suggest estimating baseline creatinine by back-calculation. The aim of this study was to evaluate different glomerular filtration rate (GFR) equations and different GFR assumptions for back-calculating baseline creatinine as well as the effect on the diagnosis of AKI. The Modification of Diet in Renal Disease, the Chronic Kidney Disease Epidemiology (CKD-EPI) and the Mayo quadratic (MQ) equation were evaluated to estimate baseline creatinine, each under the assumption of either a fixed GFR of 75 mL min -1  1.73 m -2 or an age-adjusted GFR. Estimated baseline creatinine, diagnoses and severity stages of AKI based on estimated baseline creatinine were compared to measured baseline creatinine and corresponding diagnoses and severity stages of AKI. The data of 34 690 surgical patients were analysed. Estimating baseline creatinine overestimated baseline creatinine. Diagnosing AKI based on estimated baseline creatinine had only substantial agreement with AKI diagnoses based on measured baseline creatinine [Cohen's κ ranging from 0.66 (95% CI 0.65-0.68) to 0.77 (95% CI 0.76-0.79)] and overestimated AKI prevalence with fair sensitivity [ranging from 74.3% (95% CI 72.3-76.2) to 90.1% (95% CI 88.6-92.1)]. Staging AKI severity based on estimated baseline creatinine had moderate agreement with AKI severity based on measured baseline creatinine [Cohen's κ ranging from 0.43 (95% CI 0.42-0.44) to 0.53 (95% CI 0.51-0.55)]. Diagnosing AKI and staging AKI severity on the basis of estimated baseline creatinine in surgical patients is not feasible. Patients at risk for post-operative AKI should have a pre-operative creatinine measurement to adequately assess post-operative AKI. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  13. Biodistribution of 99m technetium labeled creatinine in healthy rats

    International Nuclear Information System (INIS)

    Yilmaz, O.; Soylu, A.; Kavukcu, S.; Lambrecht, F. Yurt; Durkan, K.

    2007-01-01

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with 99m technetium ( 99m Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 ± 2% under optimum conditions (pH 7 and 100 μg stannous chloride). Rats (N 12) were injected intravenously with 99m Tc creatinine and their blood and visceral organs were evaluated for 99m Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of 99m Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  14. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    Science.gov (United States)

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P creatinine concentrations were significantly lower in the R vs. L group (Pcreatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Analytical nanosphere sensors using quantum dot-enzyme conjugates for urea and creatinine.

    Science.gov (United States)

    Ruedas-Rama, Maria J; Hall, Elizabeth A H

    2010-11-01

    An enzyme-linked analytical nanosphere sensor (ANSor) is described, responding to enzyme-substrate turnover in the vicinity of a quantum dot (QD) due to coimmobilized enzyme and pH sensitive ligand. QD capping by mercapto-alkanoic acids were rejected as a pH sensitive ligand, but with the use of a layer-by-layer assembly on mercaptopropionic capped QDs and an intermediate poly(allylamine hydrochloride) layer, anthraquinone sulfonate (calcium red, CaR) was introduced to modify the pKa in the immobilized system > 8. QD-CaR absorption shows spectral overlap with QD530 emission at all pHs and gives a complex pH dependent fluorescence resonance energy transfer (FRET) efficiency, due to excited state proton transfer (λ(ex) = 540 nm; λ(em) = 585 nm). In contrast QD615-CaR with spectral overlap between the QD and CaR gave a strong and reproducible pH response. QD-urease and QD-creatinine deiminase conjugates could be linked with pH changes produced by enzyme degradation of urea and creatinine, respectively. Close coupling between the pH sensitive QD and enzyme conjugate maximized signal compared with solution based assays: QD-urease and QD-CD bioconjugates were tested in model biological media (Dulbecco's modified Eagle's Medium and fetal calf serum) and in urine, showing a response in 3-4 min.

  16. Two novel creatinine adducts of andrographolide in human urine.

    Science.gov (United States)

    Qiu, Feng; Cui, Liang; Chen, Lixia; Sun, Jiawen; Yao, Xinsheng

    2012-09-01

    Andrographolide is a major labdane diterpenoid of the traditional Chinese and Ayurvedic medicine. Andrographis paniculate (Burm) Nees, is used in clinical situations in China mainly to treat fever, cold, and inflammation. In our previous study, fifteen metabolites of andrographolide were identified in human urine. However, there are still two other unknown metabolites. The aim of this study was to elucidate the structures of these two metabolites. 3. The two metabolites which are probably epimers were identified as creatinine adducts, and their structures were determined to be 14-deoxy-12-(creatinine-5-yl)-andrographolide-19-O-β-D-glucuronide A (Metabolite 1) and 14-deoxy-12-(creatinine-5-yl)-andrographolide-19-O-β-D-glucuronide B (Metabolite 2) by means of spectroscopic evidences. 4. It is for the first time that the formation of creatinine adducts as a novel metabolic pathway is reported. The mechanism was presumed that β-carbon (C-12) of α, β-unsaturated carbonyl was attacked by a 5-anion intermediate of creatinine formed through elimination of a proton, followed by the double bond migration from 12(13) to 13(14) and elimination of the hydroxyl group at C-14.

  17. Study on Optimization Experiment of SCR Denitrification Technologies in a Coal-fired Power Plant

    Science.gov (United States)

    Zhang, Limeng; Dong, Xinguang; Hou, Fanjun; Liu, Ke; Che, Gang

    2018-01-01

    Optimization experiment of SCR denitrification technologies on a 300MW unit was conducted. Adjustment of ammonia injection quantity of corresponding AIG was conducted after measuring the SCR export NOx concentration field in 250MW load, the distribution uniformity of NOx volume fraction at the outlet of both reactor A and B was improved significantly, where the relative standard deviation of NOx reduced respectively from 29.83% to 13.01% and 24.54% to 9.26%, simultaneously, the amount of ammonia escape of A, B reactor decrease respectively by 24.76%, 19.45%. The results of optimization experiment show that, optimal adjustment can improve the NOx concentration distribution, reduce the amount of ammonia escape in a certain extent, and judge whether the catalytic activity of the regional catalyzer is in good condition. As to the area where catalyst is ineffective, the effect of optimization experiment is limited, the catalyzer should be the timely replacement, so as to better protect downstream equipment.

  18. Monitoring the ammonia loading of zeolite-based ammonia SCR catalysts by a microwave method

    Energy Technology Data Exchange (ETDEWEB)

    Reiss, S.; Schoenauer, D.; Hagen, G.; Moos, R. [University of Bayreuth, Department of Functional Materials, Bayreuth (Germany); Fischerauer, G. [University of Bayreuth, Department of Metrology and Control, Bayreuth (Germany)

    2011-05-15

    Exhaust gas aftertreatment systems, which reduce nitrogen oxide emissions of heavy-duty diesel engines, commonly use a selective catalytic reduction (SCR) catalyst. Currently, emissions are controlled by evaluating NO{sub x} or NH{sub 3} in the gas phase downstream the catalyst and calculating the NH{sub 3} loading via a chemical storage model. Here, a microwave-cavity perturbation method is proposed in which electromagnetic waves are excited by probe feeds and the reflected signals are measured. At distinct resonance frequencies, the reflection coefficient shows a pronounced minimum. These resonance frequencies depend almost linearly on the NH{sub 3} loading of a zeolite-based SCR catalyst. Since the NH{sub 3} loading-dependent electrical properties of the catalyst material itself are measured, the amount of stored ammonia can be determined directly and in situ. The cross-sensitivity towards water can be reduced almost completely by selecting an appropriate frequency range. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Quantification of carbamylated albumin in serum based on capillary electrophoresis.

    Science.gov (United States)

    Delanghe, Sigurd; Moerman, Alena; Pletinck, Anneleen; Schepers, Eva; Glorieux, Griet; Van Biesen, Wim; Delanghe, Joris R; Speeckaert, Marijn M

    2017-09-01

    Protein carbamylation, a nonenzymatic posttranslational modification promoted during uremia, is linked to a poor prognosis. In the present study, carbamylation of serum albumin was assayed using the symmetry factor on a capillary electrophoresis instrument (Helena V8). The symmetry factor has been defined as the distance from the center line of the peak to the back slope, divided by the distance from the center line of the peak to the front slope, with all measurements made at 10% of the maximum peak height. Serum albumin, creatinine, and urea concentrations were assayed using routine methods, whereas uremic toxins were determined using HPLC. In vitro carbamylation induced a marked albumin peak asymmetry. Reference values for the albumin symmetry factor were 0.69-0.92. In kidney patients, albumin peak asymmetry corresponded to the chronic kidney disease stage (p < 0.0001). The symmetry factor correlated well with serum urea (r = -0.5595, p < 0.0001) and creatinine (r = -0.5986, p < 0.0001) concentrations. Several protein-bound uremic toxins showed a significant negative correlation with the symmetry factor. Morphology of the albumin fraction was not affected by presence of glycated albumin and protein-bound antibiotics. In conclusion, the presented method provides a simple, practical way for monitoring protein carbamylation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Phosphate, urea and creatinine clearances: haemodialysis adequacy assessed by weekly monitoring.

    Science.gov (United States)

    Debowska, Malgorzata; Wojcik-Zaluska, Alicja; Ksiazek, Andrzej; Zaluska, Wojciech; Waniewski, Jacek

    2015-01-01

    The specific distribution of phosphate and the control mechanisms for its plasma level makes phosphate kinetics during haemodialysis (HD) considerably different from those of urea and creatinine and makes the quantitative evaluation of adequacy of phosphate removal difficult. We propose the application of equivalent continuous clearance (ECC) as a phosphate adequacy parameter and compare it with ECC for creatinine and urea. Three consecutive dialysis sessions were evaluated for 25 patients on maintenance HD. Concentrations of phosphate, urea and creatinine in plasma were measured every 1h during the treatment and 45 min after, and every 30 min in dialysate. ECC was calculated using the removed solute mass assessed in dialysate and weekly solute profile in plasma. Similar calculations were performed also for the midweek dialysis session only. Different versions of the reference concentration for ECC were applied. ECC with peak average reference concentration was 5.4 ± 1.0 for phosphate, 7.0 ± 1.0 for urea and 4.7 ± 1.0 mL/min for creatinine. ECC for urea and creatinine were well correlated in contrast to the correlations of ECC for phosphate versus urea and creatinine. Midweek ECC were higher than weekly ECC, but they were well correlated for urea and creatinine, but only weakly for phosphate. HD adequacy monitoring for phosphate may be performed using ECC, but it is less predictable than similar indices for urea and creatinine. The values of ECC for phosphate are within the range expected for its molecular size compared with those for urea and creatinine. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  1. Effect of fasting ramadan in diabetes control status - application of extensive diabetes education, serum creatinine with HbA1c statistical ANOVA and regression models to prevent hypoglycemia.

    Science.gov (United States)

    Aziz, Kamran M A

    2013-09-01

    Ramadan fasting is an obligatory duty for Muslims. Unique physiologic and metabolic changes occur during fasting which requires adjustments of diabetes medications. Although challenging, successful fasting can be accomplished if pre-Ramadan extensive education is provided to the patients. Current research was conducted to study effective Ramadan fasting with different OHAs/insulins without significant risk of hypoglycemia in terms of HbA1c reductions after Ramadan. ANOVA model was used to assess HbA1c levels among different education statuses. Serum creatinine was used to measure renal functions. Pre-Ramadan diabetes education with alteration of therapy and dosage adjustments for OHAs/insulin was done. Regression models for HbA1c before Ramadan with FBS before sunset were also synthesized as a tool to prevent hypoglycemia and successful Ramadan fasting in future. Out of 1046 patients, 998 patients fasted successfully without any episodes of hypoglycemia. 48 patients (4.58%) experienced hypoglycemia. Χ(2) Test for CRD/CKD with hypoglycemia was also significant (p-value Ramadan diabetes management. Some relevant patents are also outlined in this paper.

  2. Reference intervals for selected serum biochemistry analytes in cheetahs (Acinonyx jubatus

    Directory of Open Access Journals (Sweden)

    Gavin C. Hudson-Lamb

    2016-02-01

    Full Text Available Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L – 166 mmol/L, potassium (3.9 mmol/L – 5.2 mmol/L, magnesium (0.8 mmol/L – 1.2 mmol/L, chloride (97 mmol/L – 130 mmol/L, urea (8.2 mmol/L – 25.1 mmol/L and creatinine (88 µmol/L – 288 µmol/L. Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  3. Direct determination of creatinine based on poly(ethyleneimine)/phosphotungstic acid multilayer modified electrode.

    Science.gov (United States)

    Han, Ping; Xu, Shimei; Feng, Shun; Hao, Yanjun; Wang, Jide

    2016-05-01

    In this work, the direct determination of creatinine was achieved using a poly(ethyleneimine)/phosphotungstic acid multilayer modified electrode with the assistance of Copper(II) ions by cyclic voltammetry. The quantity of creatinine were determined by measuring the redox peak current of Cu(II)-creatinine complex/Cu(I)-creatinine complex. Factors affecting the response current of creatinine at the modified electrode were optimized. A linear relationship between the response current and the concentration of creatinine ranging from 0.125 to 62.5μM was obtained with a detection limit of 0.06μM. The proposed method was applied to determine creatinine in human urine, and satisfied results were gotten which was validated in accordance with high performance liquid chromatography. The proposed electrode provided a promising alternative in routine sensing for creatinine without enzymatic assistance. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Comparative effects of mesenchymal stem cell therapy in distinct stages of chronic renal failure.

    Science.gov (United States)

    Caldas, Heloisa Cristina; de Paula Couto, Thaís Amarante Peres; Fernandes, Ida Maria Maximina; Baptista, Maria Alice Sperto Ferreira; Kawasaki-Oyama, Rosa Sayoko; Goloni-Bertollo, Eny Maria; Braile, Domingo Marcolino; Abbud-Filho, Mario

    2015-10-01

    The therapeutic potential of adult stem cells in the treatment of chronic diseases is becoming increasingly evident. In the present study, we sought to assess whether treatment with mesenchymal stem cells (MSCs) efficiently retards progression of chronic renal failure (CRF) when administered to experimental models of less severe CRF. We used two renal mass reduction models to simulate different stages of CRF (5/6 or 2/3 mass renal reduction). Renal functional parameters measured were serum creatinine (SCr), creatinine clearance (CCr), rate of decline in CCr (RCCr), and 24-h proteinuria (PT24h). We also evaluated renal morphology by histology and immunohistochemistry. MSCs were obtained from bone marrow aspirates and injected into the renal parenchyma of the remnant kidneys of both groups of rats with CRF (MSC5/6 or MSC2/3). Animals from groups MSC5/6 and CRF2/3 seemed to benefit from MSC therapy because they showed significantly reduction in SCr and PT24h, increase in CCr and slowed the RCCr after 90 days. Treatment reduced glomerulosclerosis but significant improvement did occur in the tubulointerstitial compartment with much less fibrosis and atrophy. MSC therapy reduced inflammation by decreasing macrophage accumulation proliferative activity (PCNA-positive cells) and fibrosis (α-SM-actin). Comparisons of renal functional and morphological parameters responses between the two groups showed that rats MSC2/3 were more responsive to MSC therapy than MSC5/6. This study showed that MSC therapy is efficient to retard CRF progression and might be more effective when administered during less severe stages of CRF.

  5. Heteropoly acid promoted catalyst for SCR of NOx with ammonia

    DEFF Research Database (Denmark)

    2012-01-01

    The present invention concerns the selective removal of nitrogen oxides (NOx) from gases. In particular, the invention concerns a process, a highly alkali metal resistant heteropoly acid promoted catalyst and the use of said catalyst for removal of NOx from exhaust or flue gases, said gases...... comprising alkali or earth alkali metals. Such gases comprise for example flue gases arising from the burning of biomass, combined biomass and fossil fuel, and from waste incineration units. The process comprises the selective catalytic reduction (SCR) of NOx, such as nitrogen dioxide (NO2) and nitrogen...

  6. Study on the changes of three renal functional parameters in patients with diabetic retinopathy

    International Nuclear Information System (INIS)

    Zhang Rong; Li Sumei; Zhang Li; Ye Shandong; Jin Chunyan; Ren An; Chen Ruoping; Chen Chao

    2009-01-01

    Objective: To study the relationship between development of diabetic retinopathy (DR) and changes of urinary albumin (UAlb),urine albumin-creatinine ratio (ACR), glomerular filtration rate (GFR) in patients with type 2 diabetes. Methods: Blood urea nitrogen (BUN), serum creatinine (SCr), 24 hours UAlb, ACR, radionuclide renal dynamic imaging (for GFR determination) and bilatera1 retinal photography were examined in 124 patients with type 2 diabetes. Of them 51 were without diabetic retinopathy(group A), 50 were with simple retinopathy(group B) and 23 were complicated with proliferate retinopathy(group C). Results: The UAlb, ACR in the patients with complicated diabetic retinopathy were significantly higher than those in the other two groups, while the GFR was significantly lower (P<0.05). Correlationship studies revealed that UAlb, ACR and GFR were independent risk factors of diabetic retinopathy. Conclusion: The severity of type 2 diabetes retinopathy is closely linked with the increase of UAlb, ACR and the decrease of GFR. Radionuclide renal dynamic imaging is helpful for the diagnosis of early stage of diabetic nephropathy (DN). (authors)

  7. Regeneration of Pt-catalysts deactivated in municipal waste flue gas with H2/N2 and the effect of regeneration step on the SCR catalyst

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes; Rasmussen, Søren Brik; Kustov, Arkady

    The deactivation performance of Pt-catalysts for CO oxidation has been studied in relation to use in sewage sludge municipal waste burners, where HMDS was found to poison the industrial catalyst in a similar way to the model Pt/TiO2 catalyst. A promising regeneration procedure was developed based...... on reduction with hydrogen. This procedure had negligible effect on the performance of the SCR catalyst. After treatment with 2% H2, 8% O2 in N2 for one hour, a slight better NO SCR activity was observed due to increase in the concentration V4+ sites. However, after exposure in normal NO SCR gases the activity...

  8. Correlation study of podocyte injur y and kidney function in patients with acute kidney injur y

    Directory of Open Access Journals (Sweden)

    You-Gang Feng

    2016-11-01

    Full Text Available Objective: To investigate the correlation between the podocyte injury indexes in urine such as nephrin, desmin, P-cadherin, podocin, podocalyxin and CD2-associated protein (CD2AP and the kidney function in patients with acute kidney injury (AKI. Methods: A total of 120 severe postsurgical patients treated in the Intensive Care Unit of our hospital from May 2012 to October 2015 were selected and divided into AKI group (n = 38 and non-AKI group (n = 82 according to the diagnostic criteria of AKI. After admission to the Intensive Care Unit for 24 h, their blood samples were collected to detect the contents of serum creatinine (Scr, serum urea (SUrea, b2-microglobulin (b2-MG and cystatin C (Cys-C, and urine samples were collected to detect the contents of kidney injury molecule-1 (KIM-1, liver-type fatty acid binding protein (L-FABP, Netrin-1, nephrin, desmin, P-cadherin, podocin, podocalyxin and CD2AP. Results: For patients in AKI group, the contents of Scr, SUrea, b2-MG and Cys-C in their blood samples and the contents of KIM-1, L-FABP, Netrin-1, nephrin, desmin, Pcadherin, podocin, podocalyxin and CD2AP in their urine samples were both significantly higher than those in non-AKI group. The contents of nephrin, desmin, P-cadherin, podocin, podocalyxin and CD2AP in urine samples and contents of Scr, SUrea, b2-MG, Cys-C and neutrophil gelatinase associated lipocalin in blood samples were positively correlated with the contents of KIM-1, L-FABP, and Netrin-1 in urine. Conclusions: Contents of podocyte injury molecules in urine of patients with acute kidney injury such as nephrin, desmin, P-cadherin, podocin, podocalyxin and CD2AP raised remarkably and the changes were consistent with the changes of kidney function indexes in the blood and urine samples.

  9. Sensitivitas dan Spesifisitas Cystatin C dan Kreatinin Serum dalam Mendiagnosis Cedera Ginjal Akut pada Pasien Sepsis yang Dirawat di Ruang Rawat Intensif RSUP H. Adam Malik Medan

    Directory of Open Access Journals (Sweden)

    Hasanul Arifin

    2016-08-01

    Full Text Available Serum creatinine has many limitations when being used to diagnose acute kidney injury (AKI, especially in the scope of intensive care unit due to its low sensitivity to depict the kidney dysfunctional level of critically-ill patients. Out of numerous new available biological markers, four biological markers are widely used all over the world to detect AKI, e.g. neutrophil gelatinase-associated lipocalin (NGAL, cystatin C, KIM-1, and interleukin-18. The purpose of this study was to determine the sensitivity and specificity of serum cystatin C and creatinine in establishing the diagnosis of acute kidney injury in sepsis patients treated in intensive care room. This study was a diagnostic test to 24 patients and conducted in intensive care room of H. Adam Malik Hospital during the period of February–March 2014. Population in this study is all adult patients with sepsis, severe sepsis, and septic shock in the intensive care room. A statistical test was conducted using receiving operator characteristics (ROC method using SPSS 17 software. The result of this study showed that serum cystatin C was more superior than serum creatinine in detecting acute kidney injury in sepsis patients treated in intensive care room. In this study, cystatin C had higher sensitivity, positive prediction score, negative prediction score, and area under curve-receiving operator characteristics (AUC-ROC than serum creatinine. As of specificity, there was no significant difference between these two biological markers. In conclusion, cystatin C can be an alternative biological marker to detect AKI in sepsis patients treated in intensive care room with a better diagnostic value.

  10. Improved Performance of the Potentiometric Biosensor for the Determination of Creatinine

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Zachau-Christiansen, Birgit

    2007-01-01

    The development of potentiometric biosensors for the determination of creatinine is attractive because it is a frequently analysed species in clinical chemistry. Contemporary methods of analysing creatinine engage chemicals harmful to the environment and generate large volumes of waste disposals....... By introducing a membrane-based potentiometric biosensor with immobilised creatinine deaminase, the measurements can be performed by miniaturised portable devices that are easy to handle and allow rapid analysis at a minimum consumption of chemicals. Thus, the enzymatic creatinine biosensors was revisited...... performed by flow injection analysis (FIA) showed that the response time could be lowered to approx. 30 sec. using sample volumes of 30 L. Interferences were corrected for by application of the Nicolsky-Eisenman equation thus allowing determination of creatinine in matrices resembling those of clinical...

  11. Clinical and pathological analysis of IgA nephropathy with chronic renal failure.

    Science.gov (United States)

    Liu, Yuyuan; Hu, Qinfeng; Shen, Ping; Tang, Li; Yuan, Gang; Zhou, Yongmei; Chai, Huaqi

    2016-10-01

    To investigative clinical and pathological characteristics of IgA nephropathy with chronic renal failure. Clinical and pathological findings from 65 cases of IgA nephropathy with chronic renal failure were reviewed. Pathological characteristics of all the cases were analyzed according to WHO definition and Oxford Classification. Evaluating the severity of pathological lesions by the Katafuchi R semiquantitative scoring system, and analyzing their relationship with clinical indexes of renal function. Of all 65 cases the male and female ratio was 1.4, and the mean age was 37 ± 13 years old. Levels of systolic pressure, mean arterial pressure (MAP), blood urea nitrogen (BUN), serum creatinine (Scr), uric acid (UA), album (Alb), serum IgG and 24 h urinary protein were related with eGRF level (p  0.05). IgA nephropathy with chronic renal failure usually occurred in young adults, and it had severe clinical condition and pathological changes, while there was no significant relationship between them.

  12. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  13. Late acute antibody mediated rejection after nine years of renal transplantation

    Directory of Open Access Journals (Sweden)

    Halim Medhat

    2010-01-01

    Full Text Available Acute Antibody Mediated Rejection (AMR is rarely reported as a long-term com-plication of renal transplantation, and it can present on top of another chronic pathology affecting the graft. A 45-year-old gentleman with chronic kidney disease due to unknown etiology received renal transplantation from his sister with 4 HLA mismatches. He received antithymocte globulin induction therapy and was maintained on steroids, azathioprine (AZA and cyclosporine A (CsA. Up to eight years post-transplantation he was clinically and biochemically stable. He lost follow-up for about one year, and then presented with nephritic nephrotic syndrome and rise of serum creatinine (SCr. to 210 μmol/L. Graft biopsy revealed picture suggestive of acute AMR on top of de novo membranoprolipherative glomerulonephritis (MPGN with focal crescent formation, diffuse immune complex deposition and peri-tubular capillaries C4d positivity. Anti-HLA donor specific antibodies were highly positive for B and T cells class I and class II. The patient was treated with intravenous immunoglobulin, plasma exchange and anti-CD20 (rituximab. AZA was changed to mycophenolate mofetil and CsA to tacrolimus. He had partial response, but SCr. continued at 220 μmol/L.

  14. Major issues in the design and construction of the stellarator of Costa Rica: SCR-1

    International Nuclear Information System (INIS)

    Mora, J; Vargas, V I; Villegas, L F; Barillas, L; Monge, J I; Rivas, L

    2012-01-01

    This paper aims at briefly describing the design and construction issues of the stellarator of Costa Rica 1 (SCR-1). The SCR-1 is a small modular Stellarator for magnetic confinement of plasma developed by the Plasma Physics Group of the Instituto Tecnologico de Costa Rica (ITCR). The SCR-1 is based on the small Spanish Stellarator UST 1 (Ultra Small Torus 1), created by Eng. Vicente Queral. These mains issues consist of the size of the Stellarator, closeness between coils, coupling of ECH to the vacuum chamber and the device for support. The size has become a problem because the vacuum chamber does not allow a lot of space to attach diagnosis devices, the heating system, the vacuum system and the very same support of the chamber. As a result of this lack of space, the Stellarator's coils are placed very close to each other; this means that two of the coils around of the vacuum chamber clash and cannot be placed as designed. The issue regarding the coupling of the ECH (electron cyclotron radio-frequency) to the vacuum chamber comprises the fact that the wave guide with rectangular shape does not match the CF port with circular shape on the vacuum chamber. In addition, the device for supporting the Stellarator has presented a challenge because of its size and the placement of the coils; in other words, there is not enough space between the ports and coils in the Stellarator to place appropriately the device for support.

  15. DETERMINING URINARY CREATININE BY ALKALINE PICRATE METHOD AND HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    OpenAIRE

    戎, 利光; 目, 不二雄; 菅原, 泰一

    1986-01-01

    Urinary creatinine has been widely analyzed in research fields concerning body composition and muscular activities since the amount of creatinine excretion in urine is nearly proportional to the muscular mass in humans, and the amount in an individual is nearly constant. And also research studies pointed out the decrease in urinary creatinine after acute exercise. Effects of exercise upon urinary creatinine have been, furthermore, reported. However, there are research studies indicating that ...

  16. Serum Soluble Fms-Like Tyrosine Kinase 1 (sFlt-1 Predicts the Severity of Acute Pancreatitis

    Directory of Open Access Journals (Sweden)

    Paulina Dumnicka

    2016-12-01

    Full Text Available Organ failure is the most important determinant of the severity of acute pancreatitis (AP. Soluble fms-like tyrosine kinase 1 (sFlt-1 is positively associated with organ failure in sepsis. Our aim was to evaluate the diagnostic utility of automated sFlt-1 measurements for early prediction of AP severity. Adult patients (66 with AP were recruited, including 46 with mild (MAP, 15 with moderately-severe (MSAP and 5 with severe AP (SAP. Serum and urine samples were collected twice. Serum sFlt-1 was measured with automated electrochemiluminescence immunoassay. Serum concentrations of sFlt-1 were significantly higher in patients with MSAP and SAP as compared to MAP. SAP patients had the highest concentrations. At 24 and 48 h, sFlt-1 positively correlated with inflammatory markers (leukocyte count, C-reactive protein, kidney function (creatinine, urea, cystatin C, serum and urine neutrophil gelatinase-associated lipocalin, urine albumin/creatinine ratio, D-dimer and angiopoietin-2. sFlt-1 positively correlated with the bedside index of severity in AP (BISAP score and the duration of hospital stay. Serum sFlt-1 above 139 pg/mL predicted more severe AP (MSAP + SAP. In the early phase of AP, sFlt-1 is positively associated with the severity of AP and predicts organ failure, in particular kidney failure. Serum sFlt-1 may be a practical way to improve early assessment of AP severity.

  17. Testosterone replacement elevates the serum uric acid levels in patients with female to male gender identity disorder.

    Science.gov (United States)

    Kurahashi, Hiroaki; Watanabe, Masami; Sugimoto, Morito; Ariyoshi, Yuichi; Mahmood, Sabina; Araki, Motoo; Ishii, Kazushi; Nasu, Yasutomo; Nagai, Atsushi; Kumon, Hiromi

    2013-01-01

    Gender identity disorder (GID) results from a disagreement between a person's biological sex and the gender to which he or she identifies. With respect to the treatment of female to male GID, testosterone replacement therapy (TRT) is available. The uric acid (UA) level can be influenced by testosterone; however, the early effects and dose-dependency of TRT on the serum UA concentration have not been evaluated in this population. We herein conducted a dose-response analysis of TRT in 160 patients with female to male GID. The TRT consisted of three treatment groups who received intramuscular injections of testosterone enanthate: 125 mg every two weeks, 250 mg every three weeks and 250 mg every two weeks. Consequently, serum UA elevation was observed after three months of TRT and there was a tendency toward testosterone dose-dependency. The onset of hyperuricemia was more prevalent in the group who received the higher dose. We also demonstrated a positive correlation between increased levels of serum UA and serum creatinine. Since the level of serum creatinine represents an individual's muscle volume and the muscle is a major source of purine, which induces UA upregulation, the serum UA elevation observed during TRT is at least partially attributed to an increase in muscle mass. This is the first study showing an association between serum UA elevation and a TRT-induced increase in muscle mass. The current study provides important information regarding TRT for the follow-up and management of the serum UA levels in GID patients.

  18. Stability of creatinine and cystatin C in whole blood

    NARCIS (Netherlands)

    Spithoven, E. M.; Bakker, S. J. L.; Kootstra-Ros, J.E.; de Jong, P. E.; Gansevoort, R. T.

    2013-01-01

    Background: As yet little is known about the effect of delayed separation of whole blood stored at room temperature on the stability of the kidney function markers creatinine and cystatin C. Methods: We used plasma samples of 45 patients with a wide range of creatinine and cystatin C concentration.

  19. Increasing the sensitivity of the Jaffe reaction for creatinine

    Science.gov (United States)

    Tom, H. Y.

    1973-01-01

    Study of analytical procedure has revealed that linearity of creatinine calibration curve can be extended by using 0.03 molar picric acid solution made up in 70 percent ethanol instead of water. Three to five times more creatinine concentration can be encompassed within linear portion of calibration curve.

  20. New developments of high dust-SCR technology in the cement industry results of pilot tests in Solnhofen and development state of a full scale SCR unit; Nouveaux developpements de la technologie SCR ''High Dust'' dans l'industrie du ciment - resultats de tests pilotes a Solnhoffen et etat de developpement d'une unite pilote a l'echelle

    Energy Technology Data Exchange (ETDEWEB)

    Samant, G. [Lurgi Energie und Entsorgung GmbH, Frankfurt (Germany); Sauter, G. [Soinhofer Portland Zementwerke AG, Solnhofen (Germany); Haug, N. [Agence Federale de l' Environnement, Berlin (Germany)

    2001-07-01

    The production of clinker in the cement industry involve the formation of nitrous oxides, and the emission limits are becoming more stringent from year to year. The added up total NOx emissions from the European cement industry amounts at present approx. 450.000 Mg/year. As such it is high time for the decision to develop and implement a technology to reduce NOx-emissions. At present SCR technology which is implemented in the glass industry, waste incineration and power plants seems to be the best economical and ecological solution for cement industry. In the period time from 1997 to the end of 1999 pilot plant test work was carried out by the companies 'Solnhofer Portland Zementwerke AG' and 'mg Engineering Lurgi' in the cement plant in Solnhofen. The results of pilot plan test work show that NOx reduction rates above 90% with NH{sub 3} slip less then 5 vppm can be achieved. The results of the test work with different type of catalysts are discussed. Based on the results of the test work a suitable SCR-process for cement industry is developed. At present a High-Dust-SCR demonstration plant at 'Solnhofer Portland Zementwerke AG' with the help of German Federal Environmental Agency, UBA-Berlin, is under commissioning and going on stream. (authors)