WorldWideScience

Sample records for serum creatinine measurements

  1. Serum Creatinine: Not So Simple!

    Science.gov (United States)

    Delanaye, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDMS traceability), analytical interferences, analytical coefficient of variation (CV), biological CV and critical difference. Because the relationship between serum creatinine and glomerular filtration rate is hyperbolic, all these CVs will impact not only the precision of serum creatinine but still more the precision of different creatinine-based equations, especially in low or normal-low creatinine levels (or high or normal-high glomerular filtration rate range). © 2017 S. Karger AG, Basel.

  2. Serum Creatinine: Not So Simple!

    OpenAIRE

    DELANAYE, Pierre; Cavalier, Etienne; Pottel, Hans

    2017-01-01

    Measuring serum creatinine is cheap and commonly done in daily practice. However, interpretation of serum creatinine results is not always easy. In this review, we will briefly remind the physiological limitations of serum creatinine due notably to its tubular secretion and the influence of muscular mass or protein intake on its concentration. We mainly focus on the analytical limitations of serum creatinine, insisting on important concept such as reference intervals, standardization (and IDM...

  3. Creatinine generation from kinetic modeling with or without postdialysis serum creatinine measurement: results from the HEMO study.

    Science.gov (United States)

    Daugirdas, John T; Depner, Thomas A

    2017-11-01

    A convenient method to estimate the creatinine generation rate and measures of creatinine clearance in hemodialysis patients using formal kinetic modeling and standard pre- and postdialysis blood samples has not been described. We used data from 366 dialysis sessions characterized during follow-up month 4 of the HEMO study, during which cross-dialyzer clearances for both urea and creatinine were available. Blood samples taken at 1 h into dialysis and 30 min and 60 min after dialysis were used to determine how well a two-pool kinetic model could predict creatinine concentrations and other kinetic parameters, including the creatinine generation rate. An extrarenal creatinine clearance of 0.038 l/kg/24 h was included in the model. Diffusive cross-dialyzer clearances of urea [230 (SD 37 mL/min] correlated well (R2 = 0.78) with creatinine clearances [164 (SD 30) mL/min]. When the effective diffusion volume flow rate was set at 0.791 times the blood flow rate for the cross-dialyzer clearance measurements at 1 h into dialysis, the mean calculated volume of creatinine distribution averaged 29.6 (SD 7.2) L], compared with 31.6 (SD 7.0) L for urea (P creatinine generation rate [1183 (SD 463) mg/day] averaged 100.1 % (SD 29; median 99.3) of that predicted in nondialysis patients by an anthropometric equation. A simplified method for modeling the creatinine generation rate using the urea distribution volume and urea dialyzer clearance without use of the postdialysis serum creatinine measurement gave results for creatinine generation rate [1187 (SD 475) mg/day; that closely matched the value calculated using the formally modeled value, R2 = 0.971]. Our analysis confirms previous findings of similar distribution volumes for creatinine and urea. After taking extra-renal clearance into consideration, the creatinine generation rate in dialysis patients is similar to that in nondialysis patients. A simplified method based on urea clearance

  4. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  5. Modeling Serum Creatinine in Septic ICU Patients

    DEFF Research Database (Denmark)

    De Gaetano, Andrea; Cortese, Giuliana; Pedersen, Morten Gram

    2004-01-01

    Serum creatinine is a metabolite assumed to be constantly produced by the normally functioning muscle mass and is a good measure for monitoring daily renal function in the intensive care unit (ICU). High serum creatinine levels or an abnormal departure from normal pre-disease basal levels....... The present work details the structure of a model describing observed creatinine serum concentration (CSC) variations, depending on the time-varying septic insult to renal function in ICU patients, as well as the estimation of its parameters. CSC determinations were routinely obtained from 12 patients...

  6. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  7. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  8. The role of the uncertainty of measurement of serum creatinine concentrations in the diagnosis of acute kidney injury.

    Science.gov (United States)

    Kin Tekce, Buket; Tekce, Hikmet; Aktas, Gulali; Uyeturk, Ugur

    2016-01-01

    Uncertainty of measurement is the numeric expression of the errors associated with all measurements taken in clinical laboratories. Serum creatinine concentration is the most common diagnostic marker for acute kidney injury. The goal of this study was to determine the effect of the uncertainty of measurement of serum creatinine concentrations on the diagnosis of acute kidney injury. We calculated the uncertainty of measurement of serum creatinine according to the Nordtest Guide. Retrospectively, we identified 289 patients who were evaluated for acute kidney injury. Of the total patient pool, 233 were diagnosed with acute kidney injury using the AKIN classification scheme and then were compared using statistical analysis. We determined nine probabilities of the uncertainty of measurement of serum creatinine concentrations. There was a statistically significant difference in the number of patients diagnosed with acute kidney injury when uncertainty of measurement was taken into consideration (first probability compared to the fifth p = 0.023 and first probability compared to the ninth p = 0.012). We found that the uncertainty of measurement for serum creatinine concentrations was an important factor for correctly diagnosing acute kidney injury. In addition, based on the AKIN classification scheme, minimizing the total allowable error levels for serum creatinine concentrations is necessary for the accurate diagnosis of acute kidney injury by clinicians.

  9. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  10. Critical serum creatinine values in very preterm newborns.

    Directory of Open Access Journals (Sweden)

    Alexandra Bruel

    Full Text Available BACKGROUND: Renal failure in neonates is associated with an increased risk of mortality and morbidity. But critical values are not known. OBJECTIVE: To define critical values for serum creatinine levels by gestational age in preterm infants, as a predictive factor for mortality and morbidity. STUDY DESIGN: This was a retrospective study of all preterm infants born before 33 weeks of gestational age, hospitalized in Nantes University Hospital NICU between 2003 and 2009, with serum creatinine levels measured between postnatal days 3 to 30. Children were retrospectively randomized into either training or validation set. Critical creatinine values were defined within the training set as the 90(th percentile values of highest serum creatinine (HSCr in infants with optimal neurodevelopmental at two years of age. The relationship between these critical creatinine values and neonatal mortality, and non-optimal neural development at two years, was then assessed in the validation set. RESULTS AND CONCLUSION: The analysis involved a total of 1,461 infants (gestational ages of 24-27 weeks (n=322, 28-29 weeks (n=336, and 30-32 weeks (803, and 14,721 creatinine assessments. The critical values determined in the training set (n=485 were 1.6, 1.1 and 1.0 mg/dL for each gestational age group, respectively. In the validation set (n=976, a serum creatinine level above the critical value was significantly associated with neonatal mortality (Odds ratio: 8.55 (95% confidence interval: 4.23-17.28; p<0.01 after adjusting for known renal failure risk factors, and with non-optimal neurodevelopmental outcome at two years (odds ratio: 2.06 (95% confidence interval: 1.26-3.36; p=0.004 before adjustment. Creatinine values greater than 1.6, 1.1 and 1.0 mg/dL respectively at 24-27, 28-29, 30-32 weeks of gestation were associated with mortality before and after adjustment for risk factors, and with non-optimal neurodevelopmental outcome, before adjustment.

  11. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  12. A comparison of definitions of contrast-induced nephropathy in patients with normal serum creatinine

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Khatami

    2016-01-01

    Full Text Available Contrast-induced nephropathy (CIN is the third leading cause of acute kidney injury in hospitalized patients. The prevalence of CIN is reported to range from 0% to 50%, depending not only on patient condition and the procedure used but also the definition of CIN applied. We aimed to determine the best diagnostic indicator of CIN in patients with normal serum creatinine. This study included 206 patients with normal serum creatinine who underwent coronary angiography/angioplasty. Serum creatinine level and glomerular filtration rate (GFR were measured before and on the second and fifth days after contrast administration. The incidence of CIN based on a 25% increase in serum creatinine was calculated and compared with the incidence based on a 25% decrease in GFR or an increase of at least 0.5 mg/dL in serum creatinine. Of 206 patients, 127 were male (61.7% and 79 were female (38.3%; the mean age was 59.56 ± 10.3 years. The prevalence of CIN was 30% based on a 25% increase in serum creatinine, 23% based on a 25% decrease in GFR (P <0.012 and 3.8% based on a serum creatinine increase of at least 0.5 mg/dL (P <0.0001. The serum creatinine levels remained within the normal range in the majority of patients with CIN based on the different definitions. In patients with normal serum creatinine, the absolute increase in serum creatinine may describe the prevalence of CIN more accurately than the relative increase in serum creatinine or relative decrease in GFR.

  13. Sigma metric analysis for performance of creatinine with fresh frozen serum.

    Science.gov (United States)

    Kang, Fengfeng; Zhang, Chuanbao; Wang, Wei; Wang, Zhiguo

    2016-01-01

    Six sigma provides an objective and quantitative methodology to describe the laboratory testing performance. In this study, we conducted a national trueness verification scheme with fresh frozen serum (FFS) for serum creatinine to evaluate its performance in China. Two different concentration levels of FFS, targeted with reference method, were sent to 98 laboratories in China. Imprecision and bias of the measurement procedure were calculated for each participant to further evaluate the sigma value. Quality goal index (QGI) analysis was used to investigate the reason of unacceptable performance for laboratories with σ high concentration of creatinine had preferable sigma values. For the enzymatic method, 7.0% (5/71) to 45.1% (32/71) of the laboratories need to improve their measurement procedures (σ 1.2). Only 3.1-5.3% of the laboratories should improve both of the precision and trueness. Sigma metric analysis of the serum creatinine assays is disappointing, which was mainly due to the unacceptable analytical bias according to the QGI analysis. Further effort is needed to enhance the trueness of the creatinine measurement.

  14. The elevated serum urea:creatinine ratio in canine babesiosis in South Africa is not of renal origin.

    Science.gov (United States)

    de Scally, M P; Leisewitz, A L; Lobetti, R G; Thompson, P N

    2006-12-01

    Pigmented serum, usually due to free haemoglobin and/or bilirubin, is a common finding in dogs with babesiosis, resulting in interference with all biochemical tests that rely on photochemistry. This is particularly true of urea and creatinine determinations, complicating the diagnosis of acute renal failure, which is a serious complication of babesiosis. A disproportionately raised serum urea concentration of unknown origin occurs in severely anaemic canine babesiosis patients and gives rise to an increased serum urea:creatinine ratio. The assay for cystatin-C, an excellent measure of glomerular filtration rate, is unaffected by free serum haemoglobin, and due to its different intrinsic origins, is free of influence by the metabolic derangements and organ pathology, other than renal disease, encountered in canine babesiosis. Serum cystatin-C was used to compare the concentrations of serum urea and serum creatinine in dogs with the severely anaemic form of canine babesiosis as well as a canine babesiosis-free reference group. Mean serum urea and mean serum urea:creatinine ratio were significantly elevated in the babesia-infected group relative to the reference population in this study. Mean serum creatinine and mean serum cystatin-C were within the reference ranges. Therefore an elevated urea:creatinine ratio in canine babesiosis in the presence of a normal serum creatinine concentration is considered to be caused by an elevated serum urea concentration and is most likely of non-renal origin. Serum creatinine was therefore as specific a measure of renal function as serum cystatin-C in canine babesiosis in this study. The sensitivity of serum creatinine as a measure of renal function was not established by this study. Serum urea, however, proved to be of little use compared to serum cystatin-C and serum creatinine. Serum urea should therefore not be used to diagnose renal failure in canine babesiosis.

  15. Clinical evaluation of analytical variations in serum creatinine measurements : why laboratories should abandon Jaffe techniques

    NARCIS (Netherlands)

    Drion, Iefke; Cobbaert, Christa; Groenier, Klaas H.; Weykamp, Cas; Bilo, Henk J. G.; Wetzels, Jack F. M.; Kleefstra, Nanne

    2012-01-01

    Background: Non-equivalence in serum creatinine (SCr) measurements across Dutch laboratories and the consequences hereof on chronic kidney disease (CKD) staging were examined. Methods: National data from the Dutch annual external quality organization of 2009 were used. 144 participating laboratories

  16. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients

    OpenAIRE

    Venkatapathy, Ramesh; Govindarajan, Vasupradha; Oza, Nirima; Parameswaran, Sreejith; Pennagaram Dhanasekaran, Balamurali; Prashad, Karthikshree V.

    2014-01-01

    Context. Sampling blood for serum analysis is an invasive procedure. A noninvasive alternative would be beneficial to patients and health care professionals. Aim. To correlate serum and salivary creatinine levels and evaluate the role of saliva as a noninvasive alternative to serum for creatinine estimation in chronic kidney disease patients. Study Design. Case-control study. Methods. Blood and saliva samples were collected from 37 healthy individuals and 105 chronic kidney disease patients...

  17. Serum Creatinine Versus Plasma Methotrexate Levels to Predict Toxicities in Children Receiving High-dose Methotrexate.

    Science.gov (United States)

    Tiwari, Priya; Thomas, M K; Pathania, Subha; Dhawan, Deepa; Gupta, Y K; Vishnubhatla, Sreenivas; Bakhshi, Sameer

    2015-01-01

    Facilities for measuring methotrexate (MTX) levels are not available everywhere, potentially limiting administration of high-dose methotrexate (HDMTX). We hypothesized that serum creatinine alteration after HDMTX administration predicts MTX clearance. Overall, 122 cycles in 50 patients of non-Hodgkin lymphoma or acute lymphoblastic leukemia aged ≤18 years receiving HDMTX were enrolled prospectively. Plasma MTX levels were measured at 12, 24, 36, 48, 60, and 72 hours; serum creatinine was measured at baseline, 24, 48, and 72 hours. Correlation of plasma MTX levels with creatinine levels and changes in creatinine from baseline (Δ creatinine) were evaluated. Plasma MTX levels at 72 hours showed positive correlation with serum creatinine at 48 hours (P = .011) and 72 hours (P = .013) as also Δ creatinine at 48 hours (P = .042) and 72 hours (P = .045). However, cut-off value of either creatinine or Δ creatinine could not be established to reliably predict delayed MTX clearance. Greater than 50% Δ creatinine at 48 and 72 hours significantly predicted grade 3/4 leucopenia (P = .036 and P = .001, respectively) and thrombocytopenia (P = .012 and P = .009, respectively) but not mucositis (P = .827 and P = .910, respectively). Delayed MTX elimination did not predict any grade 3/4 toxicity. In spite of demonstration of significant correlation between serum creatinine and Δ creatinine with plasma MTX levels at 72 hours, cut-off value of either variable to predict MTX delay could not be established. Thus, either of these cannot be used as a surrogate for plasma MTX estimation. Interestingly, Δ creatinine effectively predicted hematological toxicities, which were not predicted by delayed MTX clearance.

  18. Differences in urine cadmium associations with kidney outcomes based on serum creatinine and cystatin C

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Kim, Nam-Soo; Lee, Byung-Kook; Parsons, Patrick J.; Spector, June; Fadrowski, Jeffrey; Jaar, Bernard G.; Steuerwald, Amy J.; Todd, Andrew C.

    2011-01-01

    Cadmium is a well-known nephrotoxicant; chronic exposure increases risk for chronic kidney disease. Recently, however, associations between urine cadmium and higher creatinine-based estimated glomerular filtration rate (eGFR) have been reported. Analyses utilizing alternate biomarkers of kidney function allow evaluation of potential mechanisms for these observations. We compared associations of urine cadmium with kidney function measures based on serum cystatin C to those with serum creatinine in 712 lead workers. Mean (standard deviation) molybdenum-corrected urine cadmium, Modification of Diet in Renal Disease (MDRD) eGFR and multi-variable cystatin C eGFR were 1.02 (0.65) μg/g creatinine, and 97.4 (19.2) and 112.0 (17.7) mL/min/1.73 m 2 , respectively. The eGFR measures were moderately correlated (r s =0.5; p 2 ; 95% confidence interval=1.6, 6.6). Urine creatinine was associated with serum creatinine-based but not cystatin-C-based eGFRs. These results support a biomarker-specific, rather than a kidney function, effect underlying the associations observed between higher urine cadmium and creatinine-based kidney function measures. Given the routine use of serum and urine creatinine in kidney and biomarker research, additional research to elucidate the mechanism(s) for these associations is essential.

  19. Relation between serum creatinine and postoperative results of open-heart surgery.

    Science.gov (United States)

    Ezeldin, Tamer H

    2013-10-01

    To determine the impact of preoperative serum creatinine level in non-dialyzable patients on postoperative morbidity and mortality. This is a prospective study, where serum creatinine was used to give primary assessment on renal function status preoperatively. This study includes 1,033 patients, who underwent coronary artery bypass grafting, or valve(s) operations. The study took place at Al-Hada Military Hospital, Taif, Kingdom of Saudi between May 2008 and January 2012. Data were statistically analyzed using Chi square (x2) test and multivariable logistic regression, to evaluate the postoperative morbidity and mortality risks associated with low serum creatinine levels. Postoperative mortality increased with high serum creatinine level >1.8 mg/dL (pcreatinine level of more than 1.8 mg/dL was associated with increased risk of re-operation for bleeding, postoperative renal failure, prolonged ventilatory support, ICU stay, and total hospital stay. Perioperative serum creatinine is strongly related to post operative morbidity and mortality in open heart surgery. High serum creatinine in non-dialyzable patients can predict the increased morbidity and mortality after cardiac operations.

  20. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  1. Lower Serum Creatinine Is Associated with Low Bone Mineral Density in Subjects without Overt Nephropathy

    Science.gov (United States)

    Huh, Ji Hye; Choi, Soo In; Lim, Jung Soo; Chung, Choon Hee; Shin, Jang Yel; Lee, Mi Young

    2015-01-01

    Background Low skeletal muscle mass is associated with deterioration of bone mineral density. Because serum creatinine can serve as a marker of muscle mass, we evaluated the relationship between serum creatinine and bone mineral density in an older population with normal renal function. Methods Data from a total of 8,648 participants (4,573 men and 4,075 postmenopausal women) aged 45–95 years with an estimated glomerular filtration rate >60 ml/min/1.73 m2 were analyzed from the Fourth Korea National Health and Nutrition Examination Survey (2008–2010). Bone mineral density (BMD) and appendicular muscle mass (ASM) were measured using dual-energy X-ray absorptiometry. Receiver operating characteristic curve analysis revealed that the cut points of serum creatinine for sarcopenia were below 0.88 mg/dl in men and 0.75 mg/dl in women. Subjects were divided into two groups: low creatinine and upper normal creatinine according to the cut point value of serum creatinine for sarcopenia. Results In partial correlation analysis adjusted for age, serum creatinine was positively associated with both BMD and ASM. Subjects with low serum creatinine were at a higher risk for low BMD (T-score ≤ –1.0) at the femur neck, total hip and lumbar spine in men, and at the total hip and lumbar spine in women after adjustment for confounding factors. Each standard deviation increase in serum creatinine was significantly associated with reduction in the likelihood of low BMD at the total hip and lumbar spine in both sexes (men: odds ratio (OR) = 0.84 [95% CI = 0.74−0.96] at the total hip, OR = 0.8 [95% CI = 0.68−0.96] at the lumbar spine; women: OR = 0.83 [95% CI = 0.73–0.95] at the total hip, OR=0.81 [95% CI = 0.67–0.99] at the lumbar spine). Conclusions Serum creatinine reflected muscle mass, and low serum creatinine was independently associated with low bone mineral density in subjects with normal kidney function. PMID:26207750

  2. [New topics regarding equations for GFR estimation based on serum creatinine and cystatin C].

    Science.gov (United States)

    Horio, Masaru

    2014-02-01

    Japanese GFR equations and CKD-EPI equations based on standardized serum creatinine and standardized cystatin C are recommended in recent Japanese CKD guides and KDIGO guidelines for CKD management, respectively. CKD-EPIcreat overestimates GFR in Japanese subjects, probably due to the difference in muscle mass between Japanese and Caucasians. Unlike CKD-EPIcreat, CKD-EPIcys performs well in Japanese subjects, indicating the advantages of using cystatin C as a GFR marker. KDIGO guidelines suggest measuring eGFRcys in adults with eGFRcreat of 45-59 ml/min/1.73 m2 who do not have markers of kidney damage if confirmation of CKD is required. Creatinine is excreted by glomerular filtration, but also secreted by the tubules. Alteration of the tubular secretion of creatinine may influence the performance of GFR equations based on serum creatinine. Multivariate analysis showed that GFR and serum albumin levels were independent parameters affecting the fractional excretion of creatinine (FE-Cr). Alteration of FE-Cr according to the serum albumin levels may be one of the reasons for the bias of GFR equations based on serum creatinine. Low GFR is a risk factor for all-cause and cardiovascular mortality in a general population. However, the relationship between eGFR and the hazard risk of events is different depending on whether cystatin C or creatinine is used to calculate eGFR. The association between eGFRcys and the hazard risk is much stronger compared with eGFRcreat. Cystatin C may be a useful alternative to creatinine for detecting a high risk of complications in a general population and subjects with CKD.

  3. Imatinib Increases Serum Creatinine by Inhibiting Its Tubular Secretion in a Reversible Fashion in Chronic Myeloid Leukemia.

    Science.gov (United States)

    Vidal-Petiot, Emmanuelle; Rea, Delphine; Serrano, Fidéline; Stehlé, Thomas; Gardin, Claude; Rousselot, Philippe; Peraldi, Marie-Noëlle; Flamant, Martin

    2016-03-01

    Monitoring renal function is important in imatinib-treated patients with chronic myeloid leukemia because serum creatinine may increase during the course of therapy. The mechanism of this increase and its reversibility on treatment cessation have never been investigated. We retrospectively analyzed data from imatinib-treated patients explored in our renal physiology unit with measurement of glomerular filtration rate (urinary clearance of (51)CrEDTA) and of urinary clearance and tubular secretion of creatinine. Results were compared with those of controls matched for measured glomerular filtration rate, age, gender, and ethnicity. We also analyzed variations of serum creatinine before and during imatinib cessation and after imatinib resumption in patients enrolled in imatinib discontinuation studies. In 4 imatinib-treated patients who underwent thorough renal exploration, the part of creatinine clearance due to tubular secretion was negligible (2.4, 3.1, -1.3, and 2.8 mL/min) and significantly lower than that measured in their respective controls (17.7 ± 5.6, 43.0 ± 18.0, 23.1 ± 6.7, and 18.6 ± 5.6 mL/min, P creatinine tubular secretion (20.3 vs. 17.9 ± 5.2 mL/min in the control population, P = .2). In 15 patients of imatinib discontinuation studies, a median decrease in serum creatinine of 17.9% was observed after imatinib cessation. Resumption of treatment in 6 patients led to a median increase in serum creatinine of 18.8%. Imatinib completely blunts tubular secretion of creatinine, a previously unreported pharmacologic property. This inhibition increases serum creatinine independently of any glomerular dysfunction and is fully reversible on imatinib cessation. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Effects of Serum Creatinine Calibration on Estimated Renal Function in African Americans: the Jackson Heart Study

    Science.gov (United States)

    Wang, Wei; Young, Bessie A.; Fülöp, Tibor; de Boer, Ian H.; Boulware, L. Ebony; Katz, Ronit; Correa, Adolfo; Griswold, Michael E.

    2015-01-01

    Background The calibration to Isotope Dilution Mass Spectroscopy (IDMS) traceable creatinine is essential for valid use of the new Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation to estimate the glomerular filtration rate (GFR). Methods For 5,210 participants in the Jackson Heart Study (JHS), serum creatinine was measured with a multipoint enzymatic spectrophotometric assay at the baseline visit (2000–2004) and re-measured using the Roche enzymatic method, traceable to IDMS in a subset of 206 subjects. The 200 eligible samples (6 were excluded, 1 for failure of the re-measurement and 5 for outliers) were divided into three disjoint sets - training, validation, and test - to select a calibration model, estimate true errors, and assess performance of the final calibration equation. The calibration equation was applied to serum creatinine measurements of 5,210 participants to estimate GFR and the prevalence of CKD. Results The selected Deming regression model provided a slope of 0.968 (95% Confidence Interval (CI), 0.904 to 1.053) and intercept of −0.0248 (95% CI, −0.0862 to 0.0366) with R squared 0.9527. Calibrated serum creatinine showed high agreement with actual measurements when applying to the unused test set (concordance correlation coefficient 0.934, 95% CI, 0.894 to 0.960). The baseline prevalence of CKD in the JHS (2000–2004) was 6.30% using calibrated values, compared with 8.29% using non-calibrated serum creatinine with the CKD-EPI equation (P creatinine measurements in the JHS and the calibrated values provide a lower CKD prevalence estimate. PMID:25806862

  5. Evaluation of Serum Cystatin C compared with Creatinine: A study in patients with Pre-eclampsia

    Directory of Open Access Journals (Sweden)

    Salma Malik Mmordas

    2015-11-01

    Full Text Available This is cross sectional study aim to evaluate of serum Cystatin C and Creatinine level among pre-clampsia patients. Hundred subjects were evaluate in this study, 50 preclampsia patients as cases and 50 healthy apparently as control groups. Serum Cystatin C and Creatinine were measuring using MISP-i2, Mindray respectively. In assessment of renal function and compare with creatin in women which diagnostic   preeclampsia.  Result showed there was significant increase in mean concentration of Cystatin C in case versus control groups with P-value 0.000, insignificant different in Creatinine level when compare case group with control group with P-value 0.706. The study conclude that serum Cystatin C is higher in preclampsia patients while Creatinine show insignificant different as serum Cystatin C as marker for glomerular filtration, may be useful as marker for renal disease in preclampsia.  

  6. Can salivary creatinine and urea levels be used to diagnose chronic kidney disease in children as accurately as serum creatinine and urea levels? A case-control study.

    Science.gov (United States)

    Renda, Rahime

    2017-11-01

    Children with chronic kidney disease (CKD) develop many metabolic changes in blood that often necessitate frequent biochemical analysis. Serum analysis is an invasive and painful procedure. It would be highly beneficial if a noninvasive alternative process to serum analysis in children were identified. Saliva can be collected noninvasively, repeatedly, and without the use of healthcare personnel. The aims of this study were to compare serum and salivary urea and creatinine levels in children with CKD and healthy controls, and to determine if salivary creatinine and urea levels can be used to diagnose CKD in children as accurately as serum creatinine and urea levels. This case-control study included 35 children with CKD and 28 healthy children as controls. Saliva and blood samples were collected for measurement of urea and creatinine levels. The urea and creatinine levels in serum and saliva in the CKD and control groups were compared using the independent samples Mann-Whitney U test. Correlations between the serum and salivary urea and creatinine levels were determined using Pearson's correlation coefficient. Receiver operating characteristic analysis was used to assess the diagnostic performance of salivary creatinine and cutoff values were identified. In the CKD group, the mean salivary creatinine level was 0.45 mg/dL and the mean salivary urea level was 0.11 mg/dL, versus 28.83 mg/dL and 21.78 mg/dL, respectively, in the control group. Stage 4 and 5 CKD patients had a mean salivary urea level of 31.35 mg/dL, as compared to 17.78 mg/dL in the control group. Serum urea and creatinine, and salivary creatinine were significantly higher in the CKD patients (regardless of disease stage) than in the controls (p creatinine. The area under the curve for salivary creatinine was 0.805. The cutoff value for salivary creatinine was 0.125 mg/dL, with a sensitivity of 82.9% and specificity of 78.6%. Based on the positive correlation between the serum and saliva

  7. Role of serum creatinine for screening renal diseases

    International Nuclear Information System (INIS)

    Younas, M.; Khan, F.A.; Sattar, A.; Kazmi, A.

    2011-01-01

    Chronic kidney disease (CKD) is a public Heath problem with increasing prevalence in Pakistan. Early identification of mild renal disease can delay its progression. Glomerular filtration rate (GFR) is the best overall index of renal function, but it is difficult to measure, so mostly clinicians rely on. serum creatinine (SCr) concentration which its own limitations. On the other hand 24 hours (h) urinary creatinine clearance (CICl) is a more sensitive marker of renal dysfunction. Presently SCr is being used in our clinical practice to screen the renal diseases which can miss mild renal dysfunctions, so this study was designed to calculate frequency of individuals having reduced GFR as determined by CrCI having normal SCr levels. (author)

  8. Choice of Reference Serum Creatinine in Defining AKI

    Science.gov (United States)

    Siew, Edward D.; Matheny, Michael E.

    2015-01-01

    Background/Aims The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. Methods We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating estimation of baseline renal function, using Pubmed and reference back-tracing within known works. Results 1) Prehospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, 2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations 3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, 4) using more specific definitions of AKI (e.g. KIDGO Stage 2 and 3) may help to reduce the effects of misclassification when using surrogate values, and 5) leveraging available clinical data may help refine the estimate of reference creatinine. Conclusions Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the

  9. Effects of serum creatinine calibration on estimated renal function in african americans: the Jackson heart study.

    Science.gov (United States)

    Wang, Wei; Young, Bessie A; Fülöp, Tibor; de Boer, Ian H; Boulware, L Ebony; Katz, Ronit; Correa, Adolfo; Griswold, Michael E

    2015-05-01

    The calibration to isotope dilution mass spectrometry-traceable creatinine is essential for valid use of the new Chronic Kidney Disease Epidemiology Collaboration equation to estimate the glomerular filtration rate. For 5,210 participants in the Jackson Heart Study (JHS), serum creatinine was measured with a multipoint enzymatic spectrophotometric assay at the baseline visit (2000-2004) and remeasured using the Roche enzymatic method, traceable to isotope dilution mass spectrometry in a subset of 206 subjects. The 200 eligible samples (6 were excluded, 1 for failure of the remeasurement and 5 for outliers) were divided into 3 disjoint sets-training, validation and test-to select a calibration model, estimate true errors and assess performance of the final calibration equation. The calibration equation was applied to serum creatinine measurements of 5,210 participants to estimate glomerular filtration rate and the prevalence of chronic kidney disease (CKD). The selected Deming regression model provided a slope of 0.968 (95% confidence interval [CI], 0.904-1.053) and intercept of -0.0248 (95% CI, -0.0862 to 0.0366) with R value of 0.9527. Calibrated serum creatinine showed high agreement with actual measurements when applying to the unused test set (concordance correlation coefficient 0.934, 95% CI, 0.894-0.960). The baseline prevalence of CKD in the JHS (2000-2004) was 6.30% using calibrated values compared with 8.29% using noncalibrated serum creatinine with the Chronic Kidney Disease Epidemiology Collaboration equation (P creatinine measurements in the JHS, and the calibrated values provide a lower CKD prevalence estimate.

  10. How to use… serum creatinine, cystatin C and GFR.

    Science.gov (United States)

    Pasala, Swetha; Carmody, J Bryan

    2017-02-01

    Glomerular filtration rate (GFR) is the best overall measure of kidney function. The GFR is relatively low at birth but increases through infancy and early childhood to reach adult levels of approximately 120 mL/min/1.73 m 2 by age 2. While GFR can be measured most accurately by the urinary clearance of an exogenous ideal filtration marker such as inulin, it is more clinically useful to estimate GFR using a single serum measurement of an endogenous biomarker such as creatinine or cystatin C. When in steady state, there is an inverse relationship between creatinine/cystatin C and GFR, allowing GFR to be estimated from either using simple equations. Because of the non-linear relationship between creatinine/cystatin C and GFR, relatively small initial increases in these markers represent significant decreases in GFR. While cystatin C is produced by all nucleated cells, creatinine is a waste product of muscle metabolism and is therefore influenced by diet and muscle mass/body habitus. Decreased GFR is used to diagnose and stage chronic kidney disease (CKD) using the Kidney Disease: Improving Global Outcomes system. A diagnosis of CKD requires GFR creatinine and urine output are used to diagnose acute kidney injury. It is possible to calculate a kinetic GFR when the creatinine is changing rapidly, though more complex calculations are required. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Inverse association between serum creatinine and mortality in acute kidney injury.

    Science.gov (United States)

    de Souza, Sergio Pinto; Matos, Rodrigo Santos; Barros, Luisa Leite; Rocha, Paulo Novis

    2014-01-01

    Sepsis is a leading precipitant of Acute Kidney Injury (AKI) in intensive care unit (ICU) patients, and is associated with a high mortality rate. We aimed to evaluate the risk factors for dialysis and mortality in a cohort of AKI patients of predominantly septic etiology. Adult patients from an ICU for whom nephrology consultation was requested were included. End-stage chronic renal failure and kidney transplant patients were excluded. 114 patients were followed. Most had sepsis (84%), AKIN stage 3 (69%) and oliguria (62%) at first consultation. Dialysis was performed in 66% and overall mortality was 70%. Median serum creatinine in survivors and non-survivors was 3.95 mg/dl (2.63 - 5.28) and 2.75 mg/dl (1.81 - 3.69), respectively. In the multivariable models, oliguria and serum urea were positively associated with dialysis; otherwise, a lower serum creatinine at first consultation was independently associated with higher mortality. In a cohort of septic AKI, oliguria and serum urea were the main indications for dialysis. We also described an inverse association between serum creatinine and mortality. Potential explanations for this finding include: delay in diagnosis, fluid overload with hemodilution of serum creatinine or poor nutritional status. This finding may also help to explain the low discriminative power of general severity scores - that assign higher risks to higher creatinine levels - in septic AKI patients.

  12. Is Doubling of Serum Creatinine a Valid Clinical 'Hard' Endpoint in Clinical Nephrology Trials?

    NARCIS (Netherlands)

    Lambers Heerspink, H. J.; Perkovic, V.; de Zeeuw, D.

    2011-01-01

    The composite of end stage renal disease (ESRD), doubling of serum creatinine and (renal) death, is a frequently used endpoint in randomized clinical trials in nephrology. Doubling of serum creatinine is a well-accepted part of this endpoint because a doubling of serum creatinine reflects a large

  13. Inverse association between serum creatinine and mortality in acute kidney injury

    Directory of Open Access Journals (Sweden)

    Sergio Pinto de Souza

    2014-12-01

    Full Text Available Introduction: Sepsis is a leading precipitant of Acute Kidney Injury (AKI in intensive care unit (ICU patients, and is associated with a high mortality rate. Objective: We aimed to evaluate the risk factors for dialysis and mortality in a cohort of AKI patients of predominantly septic etiology. Methods: Adult patients from an ICU for whom nephrology consultation was requested were included. End-stage chronic renal failure and kidney transplant patients were excluded. Results: 114 patients were followed. Most had sepsis (84%, AKIN stage 3 (69% and oliguria (62% at first consultation. Dialysis was performed in 66% and overall mortality was 70%. Median serum creatinine in survivors and non-survivors was 3.95 mg/dl (2.63 - 5.28 and 2.75 mg/dl (1.81 - 3.69, respectively. In the multivariable models, oliguria and serum urea were positively associated with dialysis; otherwise, a lower serum creatinine at first consultation was independently associated with higher mortality. Conclusion: In a cohort of septic AKI, oliguria and serum urea were the main indications for dialysis. We also described an inverse association between serum creatinine and mortality. Potential explanations for this finding include: delay in diagnosis, fluid overload with hemodilution of serum creatinine or poor nutritional status. This finding may also help to explain the low discriminative power of general severity scores - that assign higher risks to higher creatinine levels - in septic AKI patients.

  14. GFR, serum creatinine and 24-hour urine protein in evaluating renal function of patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Chi Xiaohua; Li Guiping; Liu Feng; Wang Bing; Du Li; Deng Zhifang; Li Wei

    2013-01-01

    Background: Diabetes nephropathy is a common complication of diabetes mellitus patients. Early detection of renal impairment can improve the quality of life of patients. Purpose: The value of total GFR, serum creatinine, 24-hour urine protein excretion in diabetes mellitus patients with renal impairment were evaluated. Methods: A retrospective analysis of 147 patients with diabetes undergoing routine renal dynamic imaging was undertaken. The cases were divided into three groups according to the illness duration: group I of not more than five years, group 2 of five to ten years, Gr.3: more than ten years. The 22 renal transplant donors were selected as the normal control group, The total GFR, serum creatinine and 24-hour urinary protein excretion of all patients were measured before the treatments, and the data were statistically analyzed. Results: There was no significant differences in renal function between the two kidneys of in the diabetes mellitus patients (P=0.536). Serum creatinine and total GFR had significant correlation (R 2 =0.762), but no significant relationship between the 24-hour urine protein and the total GFR or serum creatinine. In the early and middle times of renal function impairment, the total GFR and serum creatinine have significant difference in different time periods (P<0.05). During the mid-late times of renal function impairment, total GFR and serum creatinine have no statistically significant differences (P value is 0.781, 0.297). 24-hour urine protein quality had no statistical differences in each stage. However: the total GFR is more sensitive than the serum creatinine in evaluation of early impairing of renal function. Conclusions: There is significant correlation between serum creatinine and total GFR. Both of them can reflect the degree of diabetic renal injury, but the total GFR is more sensitive than serum creatinine in early degree. 24-hour urine protein quantitative can not evaluate the degree of impaired renal function alone

  15. Serum creatinine and alkaline phosphatase levels are associated with severe chronic periodontitis.

    Science.gov (United States)

    Caúla, A L; Lira-Junior, R; Tinoco, E M B; Fischer, R G

    2015-12-01

    Periodontitis may alter systemic homeostasis and influence creatinine and alkaline phosphatase levels. Therefore, the aim of this study was to evaluate the relationship between severe chronic periodontitis and serum creatinine and alkaline phosphatase levels. One hundred patients were evaluated, 66 with severe chronic periodontitis (test group) and 34 periodontally healthy controls (control group). Medical, demographic and periodontal parameters were registered. Blood sample was collected after an overnight fast and serum creatinine and alkaline phosphatase levels were determined. There were significant differences between test and control groups in ethnicity, gender and educational level (p creatinine level (p creatinine and alkaline phosphatase levels. Severe chronic periodontitis was associated to lower creatinine and higher alkaline phosphatase levels. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Kidney transplantation from deceased donors with elevated serum creatinine.

    Science.gov (United States)

    Gallinat, Anja; Leerhoff, Sabine; Paul, Andreas; Molmenti, Ernesto P; Schulze, Maren; Witzke, Oliver; Sotiropoulos, Georgios C

    2016-12-01

    Elevated donor serum creatinine has been associated with inferior graft survival in kidney transplantation (KT). The aim of this study was to evaluate the impact of elevated donor serum creatinine on short and long-term outcomes and to determine possible ways to optimize the use of these organs. All kidney transplants from 01-2000 to 12-2012 with donor creatinine ≥ 2 mg/dl were considered. Risk factors for delayed graft function (DGF) were explored with uni- and multivariate regression analyses. Donor and recipient data were analyzed with uni- and multivariate cox proportional hazard analyses. Graft and patient survival were calculated using the Kaplan-Meier method. Seventy-eight patients were considered. Median recipient age and waiting time on dialysis were 53 years and 5.1 years, respectively. After a median follow-up of 6.2 years, 63 patients are alive. 1, 3, and 5-year graft and patient survival rates were 92, 89, and 89 % and 96, 93, and 89 %, respectively. Serum creatinine level at procurement and recipient's dialysis time prior to KT were predictors of DGF in multivariate analysis (p = 0.0164 and p = 0.0101, respectively). Charlson comorbidity score retained statistical significance by multivariate regression analysis for graft survival (p = 0.0321). Recipient age (p = 0.0035) was predictive of patient survival by multivariate analysis. Satisfactory long-term kidney transplant outcomes in the setting of elevated donor serum creatinine ≥2 mg/dl can be achieved when donor creatinine is <3.5 mg/dl, and the recipient has low comorbidities, is under 56 years of age, and remains in dialysis prior to KT for <6.8 years.

  17. Evaluation of Serum Cystatin C compared with Creatinine: A study in patients with Pre-eclampsia

    OpenAIRE

    Salma Malik Mmordas; Omer Fadol Edris

    2015-01-01

    This is cross sectional study aim to evaluate of serum Cystatin C and Creatinine level among pre-clampsia patients. Hundred subjects were evaluate in this study, 50 preclampsia patients as cases and 50 healthy apparently as control groups. Serum Cystatin C and Creatinine were measuring using MISP-i2, Mindray respectively. In assessment of renal function and compare with creatin in women which diagnostic   preeclampsia.  Result showed there was significant increase in mean concentration of Cys...

  18. Low antioxidant status of serum bilirubin, uric acid, albumin and creatinine in patients with myasthenia gravis.

    Science.gov (United States)

    Yang, Dehao; Su, Zhongqian; Wu, Shengjie; Bi, Yong; Li, Xiang; Li, Jia; Lou, Kangliang; Zhang, Hongyu; Zhang, Xu

    2016-12-01

    Oxidative stress and low antioxidant status play a major role in the pathogenesis of inflammatory and autoimmune diseases. Myasthenia gravis (MG) is an autoimmune condition targeting the neuromuscular junction, and its antioxidant status is still controversial. Our study aimed to investigate the correlation between the clinical characteristics of MG and the serum antioxidant status of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine. We measured serum antioxidant molecule levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine in 380 individuals, including 166 MG and 214 healthy controls. We found that MG patients had significantly lower serum levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine than healthy controls, whether male or female. Moreover, it was also shown in our study that uric acid, albumin and creatinine levels in patients with MG were correlated with disease activity and classifications performed by the Myasthenia Gravis Foundation of America. Our findings demonstrated that serum levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine were reduced in patients with MG. This suggested an active oxidative process in MG patients who had low antioxidant status.

  19. Comparison between a serum creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.

    Science.gov (United States)

    Karimzadeh, Iman; Khalili, Hossein

    2016-06-06

    Serum cystatin C (Cys C) has a number of advantages over serum creatinine in the evaluation of kidney function. Apart from Cys C level itself, several formulas have also been introduced in different clinical settings for the estimation of glomerular filtration rate (GFR) based upon serum Cys C level. The aim of the present study was to compare a serum Cys C-based equation with Cockcroft-Gault serum creatinine-based formula, both used in the calculation of GFR, in patients receiving amphotericin B. Fifty four adult patients with no history of acute or chronic kidney injury having been planned to receive conventional amphotericin B for an anticipated duration of at least 1 week for any indication were recruited. At three time points during amphotericin B treatment, including days 0, 7, and 14, serum cystatin C as well as creatinine levels were measured. GFR at the above time points was estimated by both creatinine (Cockcroft-Gault) and serum Cys C based equations. There was significant correlation between creatinine-based and Cys C-based GFR values at days 0 (R = 0.606, P = 0.001) and 7 (R = 0.714, P creatinine-and a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B.

  20. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  1. Serum Cystatin C– Versus Creatinine-Based Definitions of Acute Kidney Injury Following Cardiac Surgery: A Prospective Cohort Study

    Science.gov (United States)

    Spahillari, Aferdita; Parikh, Chirag R.; Sint, Kyaw; Koyner, Jay L.; Patel, Uptal D.; Edelstein, Charles L.; Passik, Cary S.; Thiessen-Philbrook, Heather; Swaminathan, Madhav; Shlipak, Michael G.

    2012-01-01

    Background The primary aim of this study was to compare the sensitivity and rapidity of AKI detection by cystatin C relative to creatinine following cardiac surgery. Study Design Prospective cohort study Settings and Participants 1,150 high-risk, adult cardiac surgery patients in the TRIBE-AKI (Translational Research Investigating Biomarker Endpoints for Acute Kidney Injury) Consortium. Predictor Changes in serum creatinine and cystatin C Outcome Post-surgical incidence of AKI Measurements Serum creatinine and cystatin C were measured at the preoperative visit and daily on postoperative days 1–5. To allow comparisons between changes in creatinine and cystatin C, AKI endpoints were defined by the relative increases in each marker from baseline (25, 50 and 100%) and the incidence of AKI was compared based upon each marker. Secondary aims were to compare clinical outcomes among patients defined as having AKI by cystatin C and/or creatinine. Results Overall, serum creatinine detected more cases of AKI than cystatin C: 35% developed a ≥25% increase in serum creatinine, whereas only 23% had ≥25% increase in cystatin C (p Creatinine also had higher proportions meeting the 50% (14% and 8%, pcreatinine or cystatin C. However, for each AKI threshold, patients with AKI confirmed by both markers had significantly higher risk of the combined mortality/dialysis outcome compared with patients with AKI detected by creatinine alone (p=0.002). Limitations There were few adverse clinical outcomes, limiting our ability to detect differences in outcomes between subgroups of patients based upon their definitions of AKI. Conclusion In this large multicenter study, we found that cystatin C was less sensitive for AKI detection compared with creatinine. However, confirmation by cystatin C appeared to identify a subset of AKI patients with substantially higher risk of adverse outcomes. PMID:22809763

  2. A study of the prevalence of significant increases in serum creatinine following angiotension-converting enzyme inhibitor administration.

    Science.gov (United States)

    Thorp, M L; Ditmer, D G; Nash, M K; Wise, R; Jaderholm, P L; Smith, J D; Chan, W

    2005-05-01

    Angiontension-converting enzyme inhibitors (ACEIs) are beneficial in the treatment of diabetic and nondiabetic kidney disease, coronary artery disease and congestive heart failure. One adverse effect of ACEIs use is a rise in serum creatinine and potential renal failure. This paper attempts to quantify this risk and assess the need for pre- and post-ACEI serum creatinine measurements. A computerized search of Kaiser Permanente Northwest's electronic medical record was conducted to find patients over the age of 40 years taking lisinopril between July 1, 2000 and June 30, 2002. Patient demographic information and presence in diabetes and coronary artery disease registries was collected. A subsequent search for pre- and postlisinopril serum creatinine levels within 6 months of initial lisinopril prescription was conducted. Patients with prelisinopril creatinine 2.5 mg/dl underwent chart review to discern adverse events associated with the rise in serum creatinine. A total of 18,977 patients were prescribed lisinopril between July 1, 2000 and June 30, 2002. In all 13 166 patients had a pre- and postlisinopril creatinine checked. In all, 31 patients had a rise in creatinine from 2.5 mg/dl (0.2%). Possible contributors to rise in creatinine included congestive heart failure, dehydration and infection. No patients developed end-stage renal disease, although three died. In conclusion, end-stage renal disease is an unlikely outcome among patients prescribed lisinopril and is most likely associated with other events.

  3. Serum Creatinine Changes Associated with Critical Illness and Detection of Persistent Renal Dysfunction after AKI

    Science.gov (United States)

    Kolic, Ivana; Purdell-Lewis, Jeremy; Taylor, Rachelle; Pearse, Rupert M.; Kirwan, Christopher J.

    2014-01-01

    Background and objectives AKI is a risk factor for development or worsening of CKD. However, diagnosis of renal dysfunction by serum creatinine could be confounded by loss of muscle mass and creatinine generation after critical illness. Design, setting, participants, & measurements A retrospective, single center analysis of serum in patients surviving to hospital discharge with an intensive care unit admission of 5 or more days between 2009 and 2011 was performed. Results In total, 700 cases were identified, with a 66% incidence of AKI. In 241 patients without AKI, creatinine was significantly lower (Pcreatinine was significantly lower than baseline in all patients except those patients with severe AKI (Kidney Disease Improving Global Outcomes category 3), who had no significant difference. In a multivariable regression model, median duration of hospitalization was associated with a predicted 30% decrease (95% confidence interval, 8% to 45%) in creatinine from baseline in the absence of AKI; after allowing for this effect, AKI was associated with a 29% (95% confidence interval, 10% to 51%) increase in predicted hospital discharge creatinine. Using a similar model to exclude the confounding effect of prolonged major illness on creatinine, 148 of 700 patients (95% confidence interval, 143 to 161) would have eGFRcreatinine (a 135% increase in potential CKD diagnoses; Pcreatinine that persist to hospital discharge, potentially causing inaccurate assessment of renal function at discharge, particularly in survivors of AKI. Prospective measurements of GFR and creatinine generation are required to confirm the significance of these findings. PMID:24742481

  4. Choice of Reference Serum Creatinine in Defining Acute Kidney Injury.

    Science.gov (United States)

    Siew, Edward D; Matheny, Michael E

    2015-01-01

    The study of acute kidney injury (AKI) has expanded with the increasing availability of electronic health records and the use of standardized definitions. Understanding the impact of AKI between settings is limited by heterogeneity in the selection of reference creatinine to anchor the definition of AKI. In this mini-review, we discuss different approaches used to select reference creatinine and their relative merits and limitations. We reviewed the literature to obtain representative examples of published baseline creatinine definitions when pre-hospital data were not available, as well as literature evaluating the estimation of baseline renal function, using PubMed and reference back-tracing within known works. (1) Pre-hospital creatinine values are useful in determining reference creatinine, and in high-risk populations, the mean outpatient serum creatinine value 7-365 days before hospitalization closely approximates nephrology adjudication, (2) in patients without pre-hospital data, the eGFR 75 approach does not reliably estimate true AKI incidence in most at-risk populations, (3) using the lowest inpatient serum creatinine may be reasonable, especially in those with preserved kidney function, but may generously estimate AKI incidence and severity and miss community-acquired AKI that does not fully resolve, (4) using more specific definitions of AKI (e.g., KIDGO stages 2 and 3) may help to reduce the effects of misclassification when using surrogate values and (5) leveraging available clinical data may help refine the estimate of reference creatinine. Choosing reference creatinine for AKI calculation is important for AKI classification and study interpretation. We recommend obtaining data on pre-hospital kidney function, wherever possible. In studies where surrogate estimates are used, transparency in how they are applied and discussion that informs the reader of potential biases should be provided. Further work to refine the estimation of reference creatinine

  5. Significant association of serum creatinine with HbA1C in impaired glucose tolerant Pakistani subjects.

    Science.gov (United States)

    Farasat, Tasnim; Sharif, Saima; Naz, Shagufta; Fazal, Sabiha

    2015-01-01

    The present study was conducted to assess the serum concentration of creatinine and determine its relationship with potential risk factors of diabetes in Impaired Glucose tolerance subjects. This cross sectional study was conducted on 100 IGT patients who attended Amin Hayat diabetic center in Lahore from January 2011- June 2011. Patients with age group 34-67 years, (both sexes) were included in the study. Different demographic parameters as age, BMI, WHR, B.P, personal history and socioeconomic status were recorded. Oral Glucose Tolerance Test was performed. The biochemical parameters including HbA1c, lipid profile, urea, uric acid, creatinine and bilirubin level were measured by chemistry analyzer. A strong correlation between creatinine and HbA1c was observed. The level of creatinine was also significantly associated with age in IGT subjects. Creatinine is non-significantly correlated with Cholesterol, LDL-Chol and TG while negatively significantly associated with BMI, fasting blood glucose and HDL-Chol. The present study concluded significant association of serum creatinine with HbA1c, BMI and HDL cholesterol.

  6.  A Comparison of Serum Cystatin C and Creatinine with Glomerular FiltrationRate in Indian Patients with Chronic Kidney Disease

    Directory of Open Access Journals (Sweden)

    Ramanathan Kumaresan

    2011-11-01

    Full Text Available  Objectives: There is no literature available on the performance of cystatin C in Chronic Kidney Disease (CKD patients of Indian population based on age group. Hence, this study is aimed to compare the diagnostic performance of serum cystatin C and creatinine with measured glomerular filtration rate (GFR and estimated GFR (eGFR in subjects of Indian origin. Methods: The study was carried out at Tiruchirappalli, South India during the period of September 2010 to march 2011. One hundred and six CKD patients (82 males, 24 females were enrolled and categorized into three groups based on age. The eGFR was calculated using Cockcroft-Gault (CG and Modification of Diet in Renal Disease (MDRD formulae. Serum cystatin C was measured with a particle-enhanced nephelometric immunoassay (PENIA method. GFR was measured using 99mTC - diethylene triamine penta aceticacid (DTPA renal scan method. Results: Serum cystatin C showed significant correlation with measured GFR in all the three groups (r=-0.9735, r=-0.8975 and r=-0.7994 respectively than serum creatinine (r=-0.7380, r=- 0.6852 and r=-0.5127 respectively. Conclusion: Serum cystatin C showed a high correlation with measured GFR in young and older patients with CKD than creatinine. Thus, cystatin C is a good alternative marker to creatinine in CKD patients.

  7. Deceiving proteins! A case of lymphoma and high creatinine

    OpenAIRE

    Metraiah, El Hakem Abdelkarim; Regan, Helen; Louw, Johanna; Kidder, Dana

    2017-01-01

    Estimation of kidney function by measuring serum creatinine is one the commonest laboratory tests conducted in clinical practice. Enzymatic methods are often used to measure serum creatinine. Clinicians should be aware of the limitations of these methods, such as test interference with paraproteins.We present a case of falsely elevated serum creatinine in a patient referred for renal biopsy. The combination of fluctuating creatinine and normal blood urea level was unusual. Serum protein elect...

  8. A review on creatinine measurement techniques.

    Science.gov (United States)

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Serum urea and creatinine levels in Nigerian human malaria patients

    African Journals Online (AJOL)

    Serum urea and creatinine levels were determined in malaria patients infected with P. falciparum. Serum urea levels decreased significantly (P<0.05) in both mild (4.10 ±1.10 mmol/L) and moderate (4.40 ±1.40 mmol/L) parasitaemia when compared to control subjects (5.50 ±1.40 mmol/L). On the other hand, serum ...

  10. Deceiving proteins! A case of lymphoma and high creatinine.

    Science.gov (United States)

    Metraiah, El Hakem Abdelkarim; Regan, Helen; Louw, Johanna; Kidder, Dana

    2017-01-23

    Estimation of kidney function by measuring serum creatinine is one the commonest laboratory tests conducted in clinical practice. Enzymatic methods are often used to measure serum creatinine. Clinicians should be aware of the limitations of these methods, such as test interference with paraproteins.We present a case of falsely elevated serum creatinine in a patient referred for renal biopsy. The combination of fluctuating creatinine and normal blood urea level was unusual. Serum protein electrophoresis revealed the presence of an IgM paraprotein. Further investigations confirmed an underlying diagnosis of lymphoplasmacytoid lymphoma. This case highlights how IgM paraprotein can interfere with creatinine estimation by enzymatic assay and the utility of alternative methods of estimating serum creatinine. 2017 BMJ Publishing Group Ltd.

  11. NephroCheck data compared to serum creatinine in various clinical settings.

    Science.gov (United States)

    Pajenda, Sahra; Ilhan-Mutlu, Aysegül; Preusser, Matthias; Roka, Sebastian; Druml, Wilfred; Wagner, Ludwig

    2015-12-09

    Acute kidney injury is frequently observed at the intensive care unit, after surgery, and after toxic drug administration. A rise in serum creatinine and a fall in urine output are consequences of much earlier injury to the most sensitive part of tubular cells located at the proximal tubule. The aim of the present study was to investigate the course of two cell-cycle arrest urinary biomarkers compared to serum creatinine in four clinical settings: ischemic reperfusion injury, cardiac failure, severe acute kidney injury, and chemotherapy-induced kidney injury. A recently developed bedside test known as NephroCheck measures two urinary parameters: insulin-like growth factor binding protein 7 (IGFBP7) and tissue inhibitor of metalloproteinase-2 (TIMP-2). The test is based on a sandwich immunoassay technique. The final test output, labeled AKIRisk, is shown as a numeric result. This report revealed that [IGFBP7] · [TIMP-2] in urine rise rapidly prior to any change in serum creatinine. A unique feature of all four clinical settings is that a rapid decline predicts the recovery of kidney function. Besides, a subclinical kidney injury might be detected by the test. This bedside test detects biomarkers of renal injury. A rapid decline in AKIRisk was associated with the restoration of kidney function, whereas a prolonged high AKIRisk score was associated with end-stage renal disease. However, the dynamics seem to differ, depending on the cause and the extent of injury. Further studies will be needed to clarify the issue.

  12. Trends in the levels of urine and serum creatinine: data from NHANES 2001-2014.

    Science.gov (United States)

    Jain, Ram B

    2017-04-01

    Data from the National Health and Nutrition Examination Survey were used to study trends for urine and serum creatinine over 2001-2014 for those aged ≥20 years. In the absence of chronic kidney disease, levels of urine creatinine decreased for the total population, for those aged 20-29, 50-59, and ≥70 years, for males, and for Mexican Americans and other race/ethnicities. Levels of serum cotinine also exhibited a decreasing trend over 2001-2014 for the total population, for those aged 20-29 and 40-49 years, for females, and for non-Hispanic whites and Mexican Americans. In general, levels of serum creatinine and urine creatinine were positively correlated for chronic kidney disease stages 1-3 and negatively correlated for chronic kidney disease stages 4 and 5.

  13. Repeated serum creatinine measurement in primary care: Not all patients have chronic renal failure.

    Science.gov (United States)

    Gentille Lorente, Delicia; Gentille Lorente, Jorge; Salvadó Usach, Teresa

    2015-01-01

    To assess the prevalence of kidney failure in patients from a primary care centre in a basic healthcare district with laboratory availability allowing serum creatinine measurements. An observational descriptive cross-sectional study. A basic healthcare district serving 23,807 people aged ≥ 18 years. Prevalence of kidney failure among 17,240 patients having at least one laboratory measurement available was 8.5% (mean age 77.6 ± 12.05 years). In 33.2% of such patients an occult kidney failure was found (98.8% were women). Prevalence of chronic kidney failure among 10,011 patients having at least 2 laboratory measurements available (≥ 3 months apart) was 5.5% with mean age being 80.1 ± 10.0 years (most severely affected patients were those aged 75 to 84); 59.7% were men and 76.3% of cases were in stage 3. An occult kidney failure was found in 5.3% of patients with women being 86.2% of them (a glomerular filtration rate<60 ml/min was estimated for plasma creatinine levels of 0.9 mg/dl or higher). Comparison of present findings to those previously reported demonstrates the need for further studies on the prevalence of overall (chronic and acute) kidney failure in Spain in order to estimate the real scope of the disease. Primary care physicians play a critical role in disease detection, therapy, control and recording (in medical records). MDRD equation is useful and practical to estimate glomerular filtration rate. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  14. Changes in Serum Proteins and Creatinine levels in HIV Infected ...

    African Journals Online (AJOL)

    This study examined the level of total serum proteins and globulins in HIV infected Nigerians. 64 patients with HIV infection and 10 apparently healthy subjects were recruited from 3 hospitals in Lagos Metropolis. They were examined for the presence of TB and malaria. Serum total protein, albumin and creatinine levels ...

  15. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    Energy Technology Data Exchange (ETDEWEB)

    Erden, Ayse, E-mail: ayse.erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Sahin, Burcu Savran, E-mail: bsavrans@hotmail.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Orgodol, Horolsuren, E-mail: hoogii99@yahoo.com [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Erden, Ilhan, E-mail: erden@medicine.ankara.edu.tr [Ankara University, School of Medicine, Department of Radiology, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey); Biyikli, Zeynep, E-mail: zeynep.biyikli@gmail.com [Ankara University, School of Medicine, Department of Biostatistics, Talatpasa Bulvari, Sihhiye, 06100 Ankara (Turkey)

    2011-11-15

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  16. Relationship between levels of serum creatinine and perirenal hyperintensity on heavily T2-weighted MR images

    International Nuclear Information System (INIS)

    Erden, Ayse; Sahin, Burcu Savran; Orgodol, Horolsuren; Erden, Ilhan; Biyikli, Zeynep

    2011-01-01

    Objective: To determine the frequency of perirenal hyperintensity on heavily T2-weighted images and to evaluate its relationship with serum creatinine levels. Subjects and methods: Axial and coronal single-shot fast spin-echo images which have been originally obtained for MR cholangiopancreatography in 150 subjects were examined by two observers individually for the presence of perirenal hyperintensity. The morphologic properties of perirenal hyperintensity (peripheral rim-like, discontinuous, polar) were recorded. Chi square test was used to test whether the frequencies of bilateral perirenal hyperintensity differ significantly in subjects with high serum creatinine levels and those with normal creatinine levels. This test was also used to compare the frequencies of perirenal hyperintensity in patients with and without renal cysts and in patients with and without corticomedullary differentiation. A p value of less than 0.05 was considered to be statistically significant. Results: The perirenal hyperintensity was identified in 40 of 150 cases (26.6%) on heavily T2-weighted image. Serum creatinine levels were high in 18 of 150 cases (12%). The perirenal hyperintensity was present in 11 of 18 subjects (61%) with high serum creatinine levels and 26 of 132 subjects (19.7%) with normal creatinine levels. The difference of rates in two groups was statistically significant. Odds ratio was 6407 (95% confidence interval 2264-18,129). The frequency of perirenal hyperintensity was also significantly higher in subjects with renal cyst or cysts in whom serum creatinine levels were normal (p < 0.05) (37.5% vs. 11.8%). Conclusion: Perirenal hyperintensities are more frequent in patients with high serum creatinine levels. They are also more common in patients with simple renal cysts.

  17. Reference intervals for serum cystatin C and creatinine of an ...

    African Journals Online (AJOL)

    Background and Aim: Estimation of the glomerular filtration rate (GFR) is important for the evaluation of patients with kidney disease. Some studies suggest that GFR estimated from serum cystatin C (Cys C) is more accurate than that from serum creatinine (SCr). For Cys C to be used for this purpose, normal values need to ...

  18. Reference Ranges of Serum Blood Urea Nitrogen, Creatinine Concentration and Ultrasonographic Measurement of the Kidneys in Term Healthy Newborns in the Neonatal Period

    Directory of Open Access Journals (Sweden)

    Şebnem Kader

    2017-12-01

    Full Text Available Objective: Acute kidney injury is an important problem in neonates. We conducted a cross-sectional prospective study to determine normal serum blood urea nitrogen, creatinine reference ranges and ranges of ultrasonographic measurement of kidneys in healthy term newborns. Study Design: Blood samples were collected from total 357 healthy newborns at birth (n=45, 1st (n=30, 3rd (n=61, 7th (n=34, 10th (n=132, 14th (n=36, and 28th (n=19 days of life. Renal ultrasonographic was performed by the same two radiologists on 81 newborns aged 10 days. Results: Serum blood urea nitrogen and creatinine concentrations have reached to the highest level at the first day of life and have returned to cord level at the third day of life. There were gradually decrease in serum blood urea nitrogen and creatinine levels after the first day of life. There were significant difference in both right and left renal length, width, and volumes in terms of gender and these parameters were statistically higher in boys than girls (p<0.05. Birth weight of the boys (3548±539g was statistically higher than girls (3307±405 g (p=0.028. There was a positive correlation between birth weight and right (r=0.38, p=0.000 and left kidney volumes (r=0.44, p=0.000. Conclusion: Our findings showed that measured blood urea nitrogen and creatinine levels changed in accordance with postnatal days and there was a positive correlation between kidney volume and birth weight of newborns. We concluded that these findings are important for evaluation of acute kidney injury and for screening of for urinary tract anomalies in neonates

  19. Monodisperse, molecularly imprinted polymers for creatinine by modified precipitation polymerization and their applications to creatinine assays for human serum and urine.

    Science.gov (United States)

    Miura, Chitose; Funaya, Noriko; Matsunaga, Hisami; Haginaka, Jun

    2013-11-01

    Molecularly imprinted polymers (MIPs) for creatinine were prepared by modified precipitation polymerization using methacrylic acid as a functional monomer and divinylbenzene as a crosslinker. The prepared MIPs were monodispersed with a narrow particle size distribution. Binding experiments and Scatchard analyses revealed that two classes of binding sites, high- and low-affinity sites, were formed on the MIPs. The retention and molecular-recognition properties of the MIPs were evaluated by hydrophilic interaction chromatography using a mixture of ammonium acetate buffer and acetonitrile as a mobile phase. With an increase of acetonitrile content, the retention factor of creatinine was increased on the MIP. In addition to shape recognition, hydrophilic interactions seemed to enhance the recognition of creatinine on the MIP. The MIPs' molecular-recognition ability was specific for creatinine; the structurally related compounds such as hydantoin, 1-methylhydantoin, 2-pyrrolidone, N-hydroxysuccinimide and creatine were not recognized. Furthermore, the creatinine concentrations in human serum and urine were successfully determined by direct injection of the deproteinized serum and diluted urine samples onto the MIP. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. The relative role of serum albumin and urinary creatinine as ...

    African Journals Online (AJOL)

    Their weight, Body mass index, serum albumin and 24-hour urinary creatinine were determined before treatment, at the end of the 1st, 2nd, 4th and 6th month of treatment. Using ANOVA, the mean values of the weight, BIM and serum albumin were analysed with further analysis paired student T- test of the pre-treatment ...

  1. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  2. Changes in serum cystatin C, creatinine, and C-reactive protein after cardiopulmonary bypass in patients with normal preoperative kidney function.

    Science.gov (United States)

    Svensson, Anders S; Kvitting, John-Peder Escobar; Kovesdy, Csaba P; Cederholm, Ingemar; Szabó, Zoltán

    2016-06-01

    The use of cardiopulmonary bypass (CPB) can cause changes in serum creatinine and cystatin C independent of glomerular filtration rate. We aimed to quantify the temporal changes of these biomarkers and C-reactive protein (CRP) after CPB. This was a prospective study at an academic medical centre between April and October 2013. We compared postoperative changes in serum creatinine and cystatin C in 38 patients with normal preoperative kidney function who underwent cardiac surgery using CPB and did not develop perioperative acute kidney injury (AKI). The effect of inflammation on intra-individual changes was examined in mixed effects regressions, using measurements of pre- and postoperative CRP. Both serum creatinine (79.9 ± 22.7 vs. 92.6 ± 21.4 µmol/L, P = 0.001) and cystatin C (1.16 ± 0.39 vs. 1.33 ± 0.37 mg/L, P = 0.012) decreased significantly in the first 8 h postoperatively compared to preoperatively, as a result of haemodilution. Thereafter serum creatinine returned to preoperative levels, whereas serum cystatin C continued to rise and was significantly elevated at 72 h post-CPB compared to preoperative levels (1.53 ± 0.48 vs. 1.33 ± 0.37 mg/L, P = 0.003). CRP levels increased significantly post-CPB and were significantly associated with increases in both serum creatinine and cystatin C. Serum creatinine and cystatin C appear not to be interchangeable biomarkers during and immediately after CPB. Processes unrelated to kidney function such as acute inflammation have a significant effect on post-CPB changes in these biomarkers, and may result in significant increases in serum cystatin C that could erroneously be interpreted as AKI. © 2015 Asian Pacific Society of Nephrology.

  3. Prognosis and serum creatinine levels in acute renal failure at the time of nephrology consultation: an observational cohort study

    Directory of Open Access Journals (Sweden)

    de Irala Jokin

    2007-09-01

    Full Text Available Abstract Background The aim of this study is to evaluate the association between acute serum creatinine changes in acute renal failure (ARF, before specialized treatment begins, and in-hospital mortality, recovery of renal function, and overall mortality at 6 months, on an equal degree of ARF severity, using the RIFLE criteria, and comorbid illnesses. Methods Prospective cohort study of 1008 consecutive patients who had been diagnosed as having ARF, and had been admitted in an university-affiliated hospital over 10 years. Demographic, clinical information and outcomes were measured. After that, 646 patients who had presented enough increment in serum creatinine to qualify for the RIFLE criteria were included for subsequent analysis. The population was divided into two groups using the median serum creatinine change (101% as the cut-off value. Multivariate non-conditional logistic and linear regression models were used. Results A ≥ 101% increment of creatinine respect to its baseline before nephrology consultation was associated with significant increase of in-hospital mortality (35.6% vs. 22.6%, p Conclusion In this cohort, patients who had presented an increment in serum level of creatinine of ≥ 101% with respect to basal values, at the time of nephrology consultation, had increased mortality rates and were discharged from hospital with a more deteriorated renal function than those with similar Liano scoring and the same RIFLE classes, but with a

  4. Lipid and Creatinine Adjustment to Evaluate Health Effects of Environmental Exposures.

    Science.gov (United States)

    O'Brien, Katie M; Upson, Kristen; Buckley, Jessie P

    2017-03-01

    Urine- and serum-based biomarkers are useful for assessing individuals' exposure to environmental factors. However, variations in urinary creatinine (a measure of dilution) or serum lipid levels, if not adequately corrected for, can directly impact biomarker concentrations and bias exposure-disease association measures. Recent methodological literature has considered the complex relationships between creatinine or serum lipid levels, exposure biomarkers, outcomes, and other potentially relevant factors using directed acyclic graphs and simulation studies. The optimal measures of urinary dilution and serum lipids have also been investigated. Existing evidence supports the use of covariate-adjusted standardization plus creatinine adjustment for urinary biomarkers and standardization plus serum lipid adjustment for lipophilic, serum-based biomarkers. It is unclear which urinary dilution measure is best, but all serum lipid measures performed similarly. Future research should assess methods for pooled biomarkers and for studying diseases and exposures that affect creatinine or serum lipids directly.

  5. How the use of creatine supplements can elevate serum creatinine in the absence of underlying kidney pathology

    Science.gov (United States)

    Williamson, Lydia; New, David

    2014-01-01

    Serum creatinine is a widely used marker in the assessment of renal function. Elevated creatinine levels suggest kidney dysfunction, prompting the need for further investigation. This report describes a case in which the consumption of the bodybuilding supplement creatine ethyl ester resulted in raised serum creatinine in the absence of true underlying kidney pathology. The abnormalities reversed after discontinuation of the supplement. A case of pseudo renal failure was recognised and kidney function was concluded to be normal. This report aims to address the mechanisms by which the ingestion of creatine ethyl ester can mimic the blood results expected in advanced renal failure, and confronts the problems faced when relying on serum creatinine as a diagnostic tool. PMID:25239988

  6. Lack of Serum Creatinine Decrease After Coronary Angiography Despite Prophylactic Hydration After Routine Coronary Angiography/Angioplasty in Stable Angina Patients--Pilot Study.

    Science.gov (United States)

    Burchardt, Pawel; Rzezniczak, Janusz; Synowiec, Tomasz; Angerer, Dariusz; Palasz, Anna; Zurawski, Jakub

    2016-01-01

    To prevent contrast induced renal dysfunction a periprocedural prophylactic hydration is applied. Due to dilution it should cause a drop in serum creatinine concentration (SCR). Surprisingly, no reduction in SCR after contrast admission is found in up to 25% of patients as early as 12-18 hours after coronary angiography/angioplasty. This study aims to find a clinical explanation as well as predict circumstances for this phenomenon. Retrospective clinical and laboratory data was used from 341 patients who underwent elective coronary angiography/angioplasty, received a prophylactic hydration, and had serum creatinine concentration measured prior to, and 12-18 hours after invasive procedure with iodine contrast administration. To exclude an improper hydration due to no creatinine decrease, the number of red blood cells was analysed as well as hemoglobin and hematocrit in blood donations collected during the study time points. The resulting lack of serum creatinine reduction could be explained by dehydration (measured by increase in number of RBC, HGB and HCT) only in 13.5% , 10.8%, and 20% of cases, respectively. Any form of abnormal glucose metabolism combined with either baseline serum creatinine concentration creatinine clearance >86.77 mL/min, or GFR by CKD EPI >80.08 mL/min/1.73 m2, or GFR by MDRD >74.48 mL/min/1.73 m2 were the predictors for no creatinine decrease at outcome. Additionally, it was demonstrated that the lack of creatinine decrease was more often observed among those patients whose initial renal function was better than in the subjects with reduction of SCR. This observation requires further prospective investigation on extended group of patients. © 2016 The Author(s) Published by S. Karger AG, Basel.

  7. Serum creatinine is associated with the prevalence but not disease progression of multiple system atrophy in Chinese population.

    Science.gov (United States)

    Cao, Bei; Guo, XiaoYan; Chen, Ke; Song, Wei; Huang, Rui; Wei, QianQian; Zhao, Bi; Shang, Hui-Fang

    2016-03-01

    Oxidative stress is involved in the pathogenesis of multiple system atrophy (MSA). Creatine, which is converted to creatinine, has an anti-oxidative effect. Our aim is to clarify the correlations between creatinine and the occurrence as well as the progression of MSA. A total of 115 patients with probable MSA and 115 age- and gender-matched healthy controls were included in the study. The serum creatinine level of all patients and controls were evaluated and compared. The mean age of MSA patients was 58.18 ± 8.67 years and the mean disease duration was 2.85 ± 1.71 years. The creatinine level of MSA patients was significantly lower than that of healthy controls (P creatinine quartiles compared with the lowest creatinine quartiles. In a gender-specific analysis, patients with the highest quartiles and second quartiles of creatinine level had decreased occurrence than patients with the lowest quartile in females, but not in males. The serum level of creatinine was not found correlated with the mean rate of annualised changes, neither with other independent factors, such as age, body mass index (BMI), sex, Unified MSA Rating Scale (UMSARS) scores and disease duration at the initial visit in patients with MSA. High level of serum creatinine may be associated with a low occurrence of MSA in Chinese population, especially in female. However, serum creatinine does not deteriorate or ameliorate the progression of MSA.

  8. Contribution of the organic anion transporter OAT2 to the renal active tubular secretion of creatinine and mechanism for serum creatinine elevations caused by cobicistat.

    Science.gov (United States)

    Lepist, Eve-Irene; Zhang, Xuexiang; Hao, Jia; Huang, Jane; Kosaka, Alan; Birkus, Gabriel; Murray, Bernard P; Bannister, Roy; Cihlar, Tomas; Huang, Yong; Ray, Adrian S

    2014-08-01

    Many xenobiotics including the pharmacoenhancer cobicistat increase serum creatinine by inhibiting its renal active tubular secretion without affecting the glomerular filtration rate. This study aimed to define the transporters involved in creatinine secretion, applying that knowledge to establish the mechanism for xenobiotic-induced effects. The basolateral uptake transporters organic anion transporter OAT2 and organic cation transporters OCT2 and OCT3 were found to transport creatinine. At physiologic creatinine concentrations, the specific activity of OAT2 transport was over twofold higher than OCT2 or OCT3, establishing OAT2 as a likely relevant creatinine transporter and further challenging the traditional view that creatinine is solely transported by a cationic pathway. The apical multidrug and toxin extrusion transporters MATE1 and MATE2-K demonstrated low-affinity and high-capacity transport. All drugs known to affect creatinine inhibited OCT2 and MATE1. Similar to cimetidine and ritonavir, cobicistat had the greatest effect on MATE1 with a 50% inhibition constant of 0.99 μM for creatinine transport. Trimethoprim potently inhibited MATE2-K, whereas dolutegravir preferentially inhibited OCT2. Cimetidine was unique, inhibiting all transporters that interact with creatinine. Thus, the clinical observation of elevated serum creatinine in patients taking cobicistat is likely a result of OCT2 transport, facilitating intracellular accumulation, and MATE1 inhibition.

  9. Contribution of the organic anion transporter OAT2 to the renal active tubular secretion of creatinine and mechanism for serum creatinine elevations caused by cobicistat

    Science.gov (United States)

    Lepist, Eve-Irene; Zhang, Xuexiang; Hao, Jia; Huang, Jane; Kosaka, Alan; Birkus, Gabriel; Murray, Bernard P; Bannister, Roy; Cihlar, Tomas; Huang, Yong; Ray, Adrian S

    2014-01-01

    Many xenobiotics including the pharmacoenhancer cobicistat increase serum creatinine by inhibiting its renal active tubular secretion without affecting the glomerular filtration rate. This study aimed to define the transporters involved in creatinine secretion, applying that knowledge to establish the mechanism for xenobiotic-induced effects. The basolateral uptake transporters organic anion transporter OAT2 and organic cation transporters OCT2 and OCT3 were found to transport creatinine. At physiologic creatinine concentrations, the specific activity of OAT2 transport was over twofold higher than OCT2 or OCT3, establishing OAT2 as a likely relevant creatinine transporter and further challenging the traditional view that creatinine is solely transported by a cationic pathway. The apical multidrug and toxin extrusion transporters MATE1 and MATE2-K demonstrated low-affinity and high-capacity transport. All drugs known to affect creatinine inhibited OCT2 and MATE1. Similar to cimetidine and ritonavir, cobicistat had the greatest effect on MATE1 with a 50% inhibition constant of 0.99 μM for creatinine transport. Trimethoprim potently inhibited MATE2-K, whereas dolutegravir preferentially inhibited OCT2. Cimetidine was unique, inhibiting all transporters that interact with creatinine. Thus, the clinical observation of elevated serum creatinine in patients taking cobicistat is likely a result of OCT2 transport, facilitating intracellular accumulation, and MATE1 inhibition. PMID:24646860

  10. Evaluation of Short-Term Changes in Serum Creatinine Level as a Meaningful End Point in Randomized Clinical Trials.

    Science.gov (United States)

    Coca, Steven G; Zabetian, Azadeh; Ferket, Bart S; Zhou, Jing; Testani, Jeffrey M; Garg, Amit X; Parikh, Chirag R

    2016-08-01

    Observational studies have shown that acute change in kidney function (specifically, AKI) is a strong risk factor for poor outcomes. Thus, the outcome of acute change in serum creatinine level, regardless of underlying biology or etiology, is frequently used in clinical trials as both efficacy and safety end points. We performed a meta-analysis of clinical trials to quantify the relationship between positive or negative short-term effects of interventions on change in serum creatinine level and more meaningful clinical outcomes. After a thorough literature search, we included 14 randomized trials of interventions that altered risk for an acute increase in serum creatinine level and had reported between-group differences in CKD and/or mortality rate ≥3 months after randomization. Seven trials assessed interventions that, compared with placebo, increased risk of acute elevation in serum creatinine level (pooled relative risk, 1.52; 95% confidence interval, 1.22 to 1.89), and seven trials assessed interventions that, compared with placebo, reduced risk of acute elevation in serum creatinine level (pooled relative risk, 0.57; 95% confidence interval, 0.44 to 0.74). However, pooled risks for CKD and mortality associated with interventions did not differ from those with placebo in either group. In conclusion, several interventions that affect risk of acute, mild to moderate, often temporary elevation in serum creatinine level in placebo-controlled randomized trials showed no appreciable effect on CKD or mortality months later, raising questions about the value of using small to moderate changes in serum creatinine level as end points in clinical trials. Copyright © 2016 by the American Society of Nephrology.

  11. Diabetic Nephropathy and CKD?Analysis of Individual Patient Serum Creatinine Trajectories: A Forgotten Diagnostic Methodology for Diabetic CKD Prognostication and Prediction

    OpenAIRE

    Onuigbo, Macaulay Amechi Chukwukadibia; Agbasi, Nneoma

    2015-01-01

    Creatinine is produced in muscle metabolism as the end-product of creatine phosphate and is subsequently excreted principally by way of the kidneys, predominantly by glomerular filtration. Blood creatinine assays constitute the most common clinically relevant measure of renal function. The use of individual patient-level real-time serum creatinine trajectories provides a very attractive and tantalizing methodology in nephrology practice. Topics covered in this review include acute kidney inju...

  12. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  13. Effect of combined treatment of angiotensin converting enzyme inhibitors and diuretics on serum creatinine levels among elderly patients

    International Nuclear Information System (INIS)

    Sweileh, Waleed M.

    2006-01-01

    The adverse effects of angiotensin converting enzyme inhibitors (ACE-I) and diuretics when given together need extensive research and attention. We performed a cross-sectional study of patients admitted to the internal department of a general medical hospital to investigate the effect of drug combinations on serum creatinine level and creatinine clearance upon admission. Age, sex, disease, status and prior consumption of the target drugs: diuretics and ACE-I were correlated with creatnine and creatinine clearance on admission. The levels of serum creatinine for groups receiving the target combination in both sexes were significantly higher than groups who were not receiving the target combination. Computing an estimate of creatinine clearance based on Cockroft equation yields similar results to that for serum level creatinine. The levels of creatinine clearance in both sexes were significantly higher in the control group compared to those receiving the target combinations. Low dose aspirin seems to have a synergistic negative effect on renal function when given in combination with the target medications. Taking ACE-I/diuretic combination was associated with significant changes in creatinine levels and creatinine clearance. Attention should be made to balance positive effects of theses medications against their negative effect on renal function. (author)

  14. Concurrence of Serum Creatinine and Albumin with Lower Risk for Death in Twice-Weekly Hemodialysis Patients

    Science.gov (United States)

    Wang, Jialin; Streja, Elani; Soohoo, Melissa; Chen, Joline L.T.; Rhee, Connie M.; Kim, Taehee; Molnar, Miklos Z.; Kovesdy, Csaba P.; Mehrotra, Rajnish; Kalantar-Zadeh, Kamyar

    2016-01-01

    Objective Markers of better nutritional status including both higher levels of serum albumin (as a measure of visceral proteins) and creatinine (as a measure of the muscle mass) are associated with lower mortality in conventional (thrice-weekly) hemodialysis patients. However, data for these associations in twice-weekly hemodialysis patients, in whom less frequent hemodialysis may confound nutritional predictors, are lacking. Design, Settings and Subjects We identified 1,113 twice-weekly and matched 4,448 thrice-weekly hemodialysis patients from a large national dialysis cohort of incident hemodialysis patients over 5 years (2007-2011). Mortality risk, adjusted for potential confounders, was examined across two-by-two combinations of serum creatinine (creatinine≥6mg/dl and albumin≥3.5g/dl as reference, patients with creatininecreatinine mortality associations between twice-weekly and thrice-weekly hemodialysis patients (p-for-interaction 0.7667). Conclusions Surrogate markers of higher visceral protein and muscle mass combined may confer greatest survival in both twice-weekly and thrice-weekly hemodialysis patients. PMID:27528412

  15. High serum creatinine nonlinearity: a renal vital sign?

    Science.gov (United States)

    Palant, Carlos E; Chawla, Lakhmir S; Faselis, Charles; Li, Ping; Pallone, Thomas L; Kimmel, Paul L; Amdur, Richard L

    2016-08-01

    Patients with chronic kidney disease (CKD) may have nonlinear serum creatinine concentration (SC) trajectories, especially as CKD progresses. Variability in SC is associated with renal failure and death. However, present methods for measuring SC variability are unsatisfactory because they blend information about SC slope and variance. We propose an improved method for defining and calculating a patient's SC slope and variance so that they are mathematically distinct, and we test these methods in a large sample of US veterans, examining the correlation of SC slope and SC nonlinearity (SCNL) and the association of SCNL with time to stage 4 CKD (CKD4) and death. We found a strong correlation between SCNL and rate of CKD progression, time to CKD4, and time to death, even in patients with normal renal function. We therefore argue that SCNL may be a measure of renal autoregulatory dysfunction that provides an early warning sign for CKD progression. Copyright © 2016 the American Physiological Society.

  16. Preliminary Findings of Serum Creatinine and Estimated Glomerular Filtration Rate (eGFR) in Adolescents with Intellectual Disabilities

    Science.gov (United States)

    Lin, Jin-Ding; Lin, Lan-Ping; Hsieh, Molly; Lin, Pei-Ying

    2010-01-01

    The present study aimed to describe the kidney function profile--serum creatinine and estimated glomerular filtration rate (eGFR), and to examine the relationships of predisposing factors to abnormal serum creatinine in people with intellectual disabilities (ID). Data were collected by a cross-sectional study of 827 aged 15-18 years adolescents…

  17. Interdialytic creatinine change versus predialysis creatinine as indicators of nutritional status in maintenance hemodialysis

    Science.gov (United States)

    Walther, Carl P.; Carter, Caitlin Wise; Low, Chai L.; Williams, Peter; Rifkin, Dena E.; Steiner, Robert W.

    2012-01-01

    Background. Protein–energy wasting is common in patients on maintenance hemodialysis and is strongly associated with poor quality of life and mortality. However, clinical assessment of protein–energy wasting remains difficult. Predialysis creatinine levels are associated with mortality risk but may be influenced by both muscle mass and dialysis dose. This might be overcome by examining the rate of rise in creatinine between dialysis sessions. Methods. We conducted an observational cohort study among 81 patients on maintenance hemodialysis at our Veterans Affairs unit. Predialysis serum creatinine and change in serum creatinine between midweek dialysis sessions served as the predictor variables of interest and clinically available proxies of nutritional status and time to mortality served as the outcome variables. Linear regression and Cox proportional hazards models evaluated relationships, respectively. Results. The mean age of the study participants was 63 ± 10 years, 77 (95%) were male, mean body mass index was 27 ± 6 kg/m2 and 69% had diabetes. Median follow-up time was 13 months, during which 12 patients (15%) died. Interdialytic change in serum creatinine showed a strong direct correlation with predialysis serum creatinine (R = 0.96). Higher levels of both markers were associated with younger age, less residual urine volume and higher serum albumin, serum phosphorus and normalized protein catabolic rate (P creatinine tertile, participants in the lowest tertile (creatinine (change creatinine and interdialytic change in creatinine are both strongly associated with proxies of nutritional status and mortality in hemodialysis patients and are highly correlated. Interdialytic change in creatinine provided little additional information about nutritional status or mortality risk above and beyond predialysis creatinine levels alone. PMID:21775764

  18. Superiority of Serum Cystatin C Over Creatinine in Prediction of Long-Term Prognosis at Discharge From ICU.

    Science.gov (United States)

    Ravn, Bo; Prowle, John R; Mårtensson, Johan; Martling, Claes-Roland; Bell, Max

    2017-09-01

    Renal outcomes after critical illness are seldom assessed despite strong correlation between chronic kidney disease and survival. Outside hospital, renal dysfunction is more strongly associated with mortality when assessed by serum cystatin C than by creatinine. The relationship between creatinine and longer term mortality might be particularly weak in survivors of critical illness. Retrospective observational cohort study. In 3,077 adult ICU survivors, we compared ICU discharge cystatin C and creatinine and their association with 1-year mortality. Exclusions were death within 72 hours of ICU discharge, ICU stay less than 24 hours, and end-stage renal disease. None. During ICU admission, serum cystatin C and creatinine diverged, so that by ICU discharge, almost twice as many patients had glomerular filtration rate less than 60 mL/min/1.73 m when estimated from cystatin C compared with glomerular filtration rate estimated from creatinine, 44% versus 26%. In 743 patients without acute kidney injury, where ICU discharge renal function should reflect ongoing baseline, discharge glomerular filtration rate estimated from creatinine consistently overestimated follow-up glomerular filtration rate estimated from creatinine, whereas ICU discharge glomerular filtration rate estimated from cystatin C well matched follow-up chronic kidney disease status. By 1 year, 535 (17.4%) had died. In survival analysis adjusted for age, sex, and comorbidity, cystatin C was near-linearly associated with increased mortality, hazard ratio equals to 1.78 (95% CI, 1.46-2.18), 75th versus 25th centile. Conversely, creatinine demonstrated a J-shaped relationship with mortality, so that in the majority of patients, there was no significant association with survival, hazard ratio equals to 1.03 (0.87-1.2), 75th versus 25th centile. After adjustment for both creatinine and cystatin C levels, higher discharge creatinine was then associated with lower long-term mortality. In contrast to creatinine

  19. Creatinine blood test

    Science.gov (United States)

    Serum creatinine; Kidney function - creatinine; Renal function - creatinine ... kidney damage or failure, infection, or reduced blood flow Loss of ... medicine overdose. Your provider will tell you more, if needed.

  20. The urinary excretion of metformin, ceftizoxime and ofloxacin in high serum creatinine rats: Can creatinine predict renal tubular elimination?

    Science.gov (United States)

    Ma, Yan-Rong; Zhou, Yan; Huang, Jing; Qin, Hong-Yan; Wang, Pei; Wu, Xin-An

    2018-03-01

    The renal excretion of creatinine and most drugs are the net result of glomerular filtration and tubular secretion, and their tubular secretions are mediated by individual transporters. Thus, we hypothesized that the increase of serum creatinine (SCr) levels attributing to inhibiting tubular transporters but not glomerular filtration rate (GFR) could be used to evaluate the tubular excretion of drugs mediated by identical or partial overlap transporter with creatinine. In this work, we firstly developed the creatinine excretion inhibition model with normal GFR by competitively inhibiting tubular transporters, and investigated the renal excretion of metformin, ceftizoxime and ofloxacin in vivo and in vitro. The results showed that the 24-hour urinary excretion of metformin and ceftizoxime in model rats were decreased by 25% and 17% compared to that in control rats, respectively. The uptake amount and urinary excretion of metformin and ceftizoxime could be inhibited by creatinine in renal cortical slices and isolated kidney perfusion. However, the urinary excretion of ofloxacin was not affected by high SCr. These results showed that the inhibition of tubular creatinine transporters by high SCr resulted to the decrease of urinary excretion of metformin and ceftizoxime, but not ofloxacin, which implied that the increase of SCr could also be used to evaluate the tubular excretion of drugs mediated by identical or partial overlap transporter with creatinine in normal GFR rats. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  2. Use of cystatin C and serum creatinine for the diagnosis of contrast-induced nephropathy in patients undergoing contrast-enhanced computed tomography at an oncology centre.

    Directory of Open Access Journals (Sweden)

    Joao Italo Fortalesa Melo

    Full Text Available Our aim was to assess renal function using as laboratory measurements serum creatinine and cystatin C concentrations before and after administration of low-osmolarity (nonionic iodinated contrast medium in patients with cancer undergoing computed tomography (CT.This prospective study included 400 oncologic outpatients. Serum creatinine and cystatin C concentrations were measured before and 72 h after contrast administration. Glomerular filtration rates (GFRs were estimated using serum creatinine-based [Modification of Diet in Renal Disease (MDRD and Cockroft-Gault and cystatin C based (Larsson equations. Exploratory data analysis was performed. The nonparametric Wilcoxon test was used to compare pre and post contrast of test results and estimated clearance. The confidence interval used in the analysis was 95%.Compared with the pre-contrast values, the mean serum creatinine concentration was significantly higher and average GFRs estimated using MDRD and Cockcroft-Gault equations were significantly lower after the administration of contrast (p <0.001. It was also observed a significant increase after contrast in the concentration of Cystatin C (p = 0.015. In addition, a decrease in GFR estimated using the average Larsson (p = 0.021 was observed between time points. However, none of the patients presented clinically significant nephropathy.Assessment using serum creatinine and cystatin C concentrations showed changes in renal function among patients with cancer undergoing contrast-enhanced CT examination in this study. No significant renal damage related to the use of low-osmolarity iodinated contrast medium of the type and dosage employed in this study was observed. This contrast medium is thus safe for use in patients with cancer.

  3. CCQM-K11.2 determination of glucose in human serum and CCQM-K12.2 determination of creatinine in human serum

    Science.gov (United States)

    Wise, Stephen A.; Phinney, Karen W.; Duewer, David L.; Sniegoski, Lorna T.; Welch, Michael J.; Pritchett, Jeanita; Pabello, Guiomar; Avila Calderon, Marco A.; Balderas, Miryan; Qinde, Liu; Kooi, Lee Tong; Rego, Eliane; Garrido, Bruno; Allegri, Gabriella; de La Cruz, Marcia; Barrabin, Juliana; Monteiro, Tânia; Lee, Hwashim; Kim, Byungjoo; Delatour, Vincent; Peignaux, Maryline; Kawaguchi, Migaku; Bei, Xu; Can, Quan; Nammoonnoy, Jintana; Schild, Katrin; Ohlendorf, Rüdiger; Henrion, Andre; Ceyhan Gören, Ahmet; Yılmaz, Hasibe; Bilsel, Mine; Konopelko, L.; Krylov, A.; Lopushanskaya, E.

    2018-01-01

    Glucose and creatinine are two of the most frequently measured substances in human blood/serum for assessing the health status of individuals. Because of their clinical significance, CCQM-K11 glucose in human serum and CCQM-K12 creatinine in human serum were the fourth and fifth key comparisons (KCs) performed by the Organic Analysis Working Group (OAWG). These KCs were conducted in parallel and were completed in 2001. The initial subsequent KCs for glucose, CCQM-K11.1, and creatinine, CCQM-K12.1, were completed in 2005. Measurements for the next KCs for these two measurands, CCQM-K11.2 and CCQM-K12.2, were completed in 2013. While designed as subsequent KCs, systematic discordances between the participants' and the anchor institution's results in both comparisons lead the OAWG to request reference results from two experienced laboratories that had participated in the 2001 comparisons. Based on the totality of the available information, the OAWG converted both CCQM-K11.2 and CCQM-K12.2 to 'Track C' KCs where the key comparison reference value is estimated by consensus. These comparisons highlighted that carrying out comparisons for complex chemical measurements and expecting to be able to treat them under the approaches used for formal CIPM subsequent comparisons is not an appropriate strategy. The approach used here is a compromise to gain the best value from the comparison; it is not an approach that will be used in the future. Instead, the OAWG will focus on Track A and Track C comparisons that are treated as stand-alone entities. Participation in CCQM-K11.2 demonstrates a laboratory's capabilities to measure a polar (pKow > 2), low molecular mass (100 g/mol to 500 g/mol) metabolite in human serum at relatively high concentrations (0.1 mg/g to 10 mg/g). Participation in CCQM-K12.2 demonstrates capabilities to measure similar classes of metabolites at relatively low concentrations (1 μg/g to 30 μg/g). The capabilities required for the analysis of complex

  4. Impact of Different Creatinine Measurement Methods on Liver Transplant Allocation

    Science.gov (United States)

    Kaiser, Thorsten; Kinny-Köster, Benedict; Bartels, Michael; Parthaune, Tanja; Schmidt, Michael; Thiery, Joachim

    2014-01-01

    Introduction The model for end-stage liver disease (MELD) score is used in many countries to prioritize organ allocation for the majority of patients who require orthotopic liver transplantation. This score is calculated based on the following laboratory parameters: creatinine, bilirubin and the international normalized ratio (INR). Consequently, high measurement accuracy is essential for equitable and fair organ allocation. For serum creatinine measurements, the Jaffé method and enzymatic detection are well-established routine diagnostic tests. Methods A total of 1,013 samples from 445 patients on the waiting list or in evaluation for liver transplantation were measured using both creatinine methods from November 2012 to September 2013 at the university hospital Leipzig, Germany. The measurements were performed in parallel according to the manufacturer’s instructions after the samples arrived at the institute of laboratory medicine. Patients who had required renal replacement therapy twice in the previous week were excluded from analyses. Results Despite the good correlation between the results of both creatinine quantification methods, relevant differences were observed, which led to different MELD scores. The Jaffé measurement led to greater MELD score in 163/1,013 (16.1%) samples with differences of up to 4 points in one patient, whereas differences of up to 2 points were identified in 15/1,013 (1.5%) samples using the enzymatic assay. Overall, 50/152 (32.9%) patients with MELD scores >20 had higher scores when the Jaffé method was used. Discussion Using the Jaffé method to measure creatinine levels in samples from patients who require liver transplantation may lead to a systematic preference in organ allocation. In this study, the differences were particularly pronounced in samples with MELD scores >20, which has clinical relevance in the context of urgency of transplantation. These data suggest that official recommendations are needed to determine which

  5. Creatinine index as a surrogate of lean body mass derived from urea Kt/V, pre-dialysis serum levels and anthropometric characteristics of haemodialysis patients.

    Directory of Open Access Journals (Sweden)

    Bernard Canaud

    Full Text Available BACKGROUND AND OBJECTIVES: Protein-energy wasting is common in long-term haemodialysis (HD patients with chronic kidney disease and is associated with increased morbidity and mortality. The creatinine index (CI is a simple and useful nutritional parameter reflecting the dietary skeletal muscle protein intake and skeletal muscle mass of the patient. Because of the complexity of creatinine kinetic modeling (CKM to derive CI, we developed a more simplified formula to estimate CI in HD patients. DESIGN, SETTING, PARTICIPANTS & MEASUREMENTS: A large database of 549 HD patients followed over more than 20 years including monthly CKM-derived CI values was used to develop a simple equation based on patient demographics, predialysis serum creatinine values and dialysis dose (spKt/V using mixed regression models. RESULTS: The equation to estimate CI was developed based on age, gender, pre-dialysis serum creatinine concentrations and spKt/V urea. The equation-derived CI correlated strongly with the measured CI using CKM (correlation coefficient  = 0.79, p-value <0.001. The mean error of CI prediction using the equation was 13.47%. Preliminary examples of few typical HD patients have been used to illustrate the clinical relevance and potential usefulness of CI. CONCLUSIONS: The elementary equation used to derive CI using demographic parameters, pre-dialysis serum creatinine concentrations and dialysis dose is a simple and accurate surrogate measure for muscle mass estimation. However, the predictive value of the simplified CI assessment method on mortality deserves further evaluation in large cohorts of HD patients.

  6. Blood creatinine level in postmortem cases.

    Science.gov (United States)

    Nishida, Atsushi; Funaki, Hironao; Kobayashi, Masaki; Tanaka, Yuka; Akasaka, Yoshihisa; Kubo, Toshikazu; Ikegaya, Hiroshi

    2015-05-01

    Blood chemical analysis for the diagnosis of diseases in forensic cases should be conducted in the same way as for clinical cases. However, it is sometimes difficult to obtain serum samples in forensic cases because of postmortem changes such as hemolysis and putrefaction. This study aimed to evaluate renal function in postmortem cases by blood creatinine analysis. The blood creatinine level was measured by high performance liquid chromatography (HPLC) using whole blood samples taken from 77 postmortem cases, and the relationships between blood creatinine level, postmortem interval, and cause of death were examined. The median blood creatinine level was found to be 1.15 mg/dL, with no significant differences between blood samples taken from different parts of the body. The blood creatinine level was stable for 3 days after death and gradually increased after that period, in line with a previous study using enzymatic analysis that found the serum creatinine level was stable in the early postmortem period. The blood creatinine level was high in the cases of blunt injury, intoxication, and in deaths caused by fire. This was considered to reflect acute renal dysfunction. However, the postmortem blood creatinine level remained higher than the clinical normal value despite omitting cases with renal dysfunction from the analysis. Therefore, we next investigated the change in postmortem creatinine levels in mice and found that the blood creatinine level increased with the emergence of rigor mortis. Our findings indicate that HPLC is useful in the postmortem evaluation of renal function even in the cases where serum cannot be obtained. However, the presence of rigor mortis should be considered in the evaluation of blood creatinine values. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Gender-Specific Differences in Baseline, Peak, and Delta Serum Creatinine: The NACSELD Experience.

    Science.gov (United States)

    O'Leary, Jacqueline G; Wong, Florence; Reddy, K Rajender; Garcia-Tsao, Guadalupe; Kamath, Patrick S; Biggins, Scott W; Fallon, Michael B; Subramanian, Ram M; Maliakkal, B; Thacker, Leroy; Bajaj, Jasmohan S

    2017-03-01

    Women have lower serum creatinine values than men for similar renal function. We aimed to determine the differential effect of baseline, peak, and delta creatinine between genders on outcomes in infected hospitalized cirrhotic patients. North American Consortium for the Study of End-Stage Liver Disease is a 15-center consortium of tertiary care hepatology centers prospectively enrolling infected cirrhotic inpatients. Baseline, peak, and delta creatinine during hospitalization were compared between genders, and their impact on overall survival, transplant-free survival, probability of transplantation, and need for renal replacement therapy (RRT) was analyzed. In total, 532 patients with cirrhosis (males = 59% median admission MELD = 20) had significantly lower median baseline (1.07 vs. 1.30 mg/dL, p creatinine (1.47 vs. 1.59 mg/dL, p = 0.024) in women than men during hospitalization for an infection, but both genders had similar delta creatinine levels (0.30 vs. 0.30 mg/dL, p = 0.957). Thirty-day mortality was similar between genders. RRT was not used more often in women (19 vs. 12%, p = 0.050), and women were 1.8 times more likely than men to receive RRT at the same creatinine (p = 0.028). Both peak and delta creatinine significantly predicted 6-month overall and transplant-free survival (p creatinine. Infected hospitalized cirrhotic women are significantly more likely than men to receive RRT at similar creatinine levels. Gender-specific differences in baseline, peak, and delta creatinine need further investigation to determine whether women need acute kidney injury treatment at lower creatinine thresholds than men.

  8. Reduced production of creatinine limits its use as marker of kidney injury in sepsis.

    Science.gov (United States)

    Doi, Kent; Yuen, Peter S T; Eisner, Christoph; Hu, Xuzhen; Leelahavanichkul, Asada; Schnermann, Jürgen; Star, Robert A

    2009-06-01

    Although diagnosis and staging of acute kidney injury uses serum creatinine, acute changes in creatinine lag behind both renal injury and recovery. The risk for mortality increases when acute kidney injury accompanies sepsis; therefore, we sought to explore the limitations of serum creatinine in this setting. In mice, induction of sepsis by cecal ligation and puncture in bilaterally nephrectomized mice increased markers of nonrenal organ injury and serum TNF-alpha. Serum creatinine, however, was significantly lower in septic animals than in animals subjected to bilateral nephrectomy and sham cecal ligation and puncture. Under these conditions treatment with chloroquine decreased nonrenal organ injury markers but paradoxically increased serum creatinine. Sepsis dramatically decreased production of creatinine in nephrectomized mice, without changes in body weight, hematocrit, or extracellular fluid volume. In conclusion, sepsis reduces production of creatinine, which blunts the increase in serum creatinine after sepsis, potentially limiting the early detection of acute kidney injury. This may partially explain why small absolute increases in serum creatinine levels are associated with poor clinical outcomes. These data support the need for new biomarkers that provide better measures of renal injury, especially in patients with sepsis.

  9. Urinary creatinine to serum creatinine ratio and renal failure index in dogs infected with Babesia canis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga; Wesołowska, Agnieszka; Wędrychowicz, Halina

    2013-09-01

    Urinary creatinine to serum creatinine (UCr/SCr) ratio and renal failure index (RFI) are useful indices of renal damage. Both UCr/SCr ratio and RFI are used in differentiation between prerenal azotaemia and acute tubular necrosis. In this work the authors calculated the UCr/SCr ratio and RFI in dogs infected with Babesia canis and the values of these indices in azotaemic dogs infected with the parasite. The results of this study showed significantly lower UCr/SCr ratio in dogs infected with B. canis than in healthy dogs. Moreover, in azotaemic dogs infected with B. canis the UCr/SCr ratio was significantly lower and the RFI was significantly higher than in non-azotaemic dogs infected with B. canis. The calculated correlation between RFI and duration of the disease before diagnosis and treatment was high, positive and statistically significant (r = 0.89, p caused by B. canis in Poland acute tubular necrosis may develop.

  10. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    Science.gov (United States)

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; Psamples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  11. Changes in the level of urea, creatine and creatinine in the liver and serum of irradiated rats

    International Nuclear Information System (INIS)

    El Kashef, H.S.; Saada, H.N.

    1991-01-01

    This study aims to compare between the susceptibility of two tissues (liver and serum) toγ-radiation with respect to some protein end-products; namely urea, creatine and creatinine. The results indicated that in control rat liver, the concentration of urea, creatine and creatinine ranged between 262-266, 106-108 and 18.86-19.48 μg/g fresh tissue, respectively. In blood serum, the concentration of these end-products were 327-383, 94-97 and 12.36-12.51μg/ml blood serum. Whole body -irradiation at dose 5.5 Gy caused significant changes in the levels of both urea and creatine in the blood serum on the 7th and 14th post irradiation days, while the level of creatinine was not altered. As for the liver of whole body γ -irradiated rats, significant changes were observed in the content of urea at the all post-irradiation days except at the 3 rd day. The creatinine content of the liver was significantly decreased on the 3 rd, 14th and 21st days after irradiation. Similar decrease was noticed in the content of creatine, but on the 7th day, significant increase was observed. The variation in the studied parameters started early in the liver and lated longer, but it started later and lasted shorter in the serum of irradiated rats. It could be suggested that the liver of irradiated rats is more sensitive to the radiation dose 5.5 Gy than the blood.1 fig.,2 tab

  12. RENAL FUNCTION TEST ON THE BASIS OF SERUM CREATININE AND UREA IN TYPE-2 DIABETICS AND NONDIABETICS

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-01-01

    Full Text Available Background: Type-2 diabetes mellitus has quickly become a global health problem due to rapidly increasing population growth, aging, urbanization and increasing prevalence of obesity and physical inactivity. Diabetic nephropathy is one of the major causes of chronic renal failure. Both serum urea and creatinine are widely used to assess the function of kidney. This study was conducted to observe the impaired renal function in type 2 diabetics and compare with non-diabetics controls. Method: To determine the incidence of renal dysfunction in diabetics in Nepalgunj medical college and Hospital , Nepalgunj , Banke, Nepal , blood samples from 100 diabetic subjects and 100 non-diabetic controls were taken between the period 1st February  , 2012  to  31st January , 2013 for investigation of  plasma glucose fasting(FPG, blood urea and serum creatinine. These biochemical parameters were determined by using a fully automated clinical chemistry analyzer. Results: Our findings showed that the level of blood urea (P<0.0001, 95%Cl and serum creatinine (P≈0.0004,95%Cl were significantly higher in type 2 diabetics as compared to non-diabetics in both male and female. There was no significant difference between diabetic male and female. 15 out of 100 diabetes samples have high urea level whereas 7 out of 100 had increased creatinine level. In control only 3 samples had high urea value and 1 had high creatinine level. There was statistical significant increased in urea level with increased in blood sugar level. Conclusion: Blood urea and creatinine is widely accepted to assess the renal functions. Good control of blood glucose level is absolute requirement to prevent progressive renal impairment.

  13. Methods for Quantitative Creatinine Determination.

    Science.gov (United States)

    Moore, John F; Sharer, J Daniel

    2017-04-06

    Reliable measurement of creatinine is necessary to assess kidney function, and also to quantitate drug levels and diagnostic compounds in urine samples. The most commonly used methods are based on the Jaffe principal of alkaline creatinine-picric acid complex color formation. However, other compounds commonly found in serum and urine may interfere with Jaffe creatinine measurements. Therefore, many laboratories have made modifications to the basic method to remove or account for these interfering substances. This appendix will summarize the basic Jaffe method, as well as a modified, automated version. Also described is a high performance liquid chromatography (HPLC) method that separates creatinine from contaminants prior to direct quantification by UV absorption. Lastly, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is described that uses stable isotope dilution to reliably quantify creatinine in any sample. This last approach has been recommended by experts in the field as a means to standardize all quantitative creatinine methods against an accepted reference. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  14. Strong negative interference of ethamsylate (Dicynone®) in serum creatinine quantification via enzymatic assay using Trinder reaction.

    Science.gov (United States)

    Wiewiorka, Ondrej; Dastych, Milan; Čermáková, Zdenka

    2013-08-01

    With discrepancies encountered as early as the verification of enzymatic method for quantification of serum creatinine, our research pointed to a later confirmed interference caused by a compound called ethamsylate present in the commonly used antihemorrhagic drug Dicynone. We measured concentrations of creatinine of 10 patients with blood taken before and 15 minutes after the intravenous administration of a 500 mg dose of Dicynone. The creatinine concentration was determined using Jaffe method and enzymatic method that utilize Trinder reaction (Roche) in analyzer Cobas c 501 (Roche AG, Basel, Switzerland). We also monitored concentration of blood creatinine in three patients before and 15 minutes after application of Dicynone (500 mg i.v.) and in the following 6th, 12th, 18th, and 24th hours. We discovered a significant negative bias in creatinine results using enzymatic assay with Trinder reaction in blood taken 15 min after i.v. application of 500 mg Dicynone to patients compared to their pre-application values (average decrease of 47%). Unlike this, the results of compensated Jaffe method yielded steady results in all samples (average deviation 0.6% from original values). However, 12 h after the drug administration comparable results were seen as before the administration. Considering the strong negative interference of ethamsylate in enzymatic assay using Trinder reaction for creatinine quantification, blood from patients with prescribed Dicynone should be taken at least 12 h after the last application of the drug for obtaining the correct creatinine values.

  15. Elevated serum creatinine and low albumin are associated with poor outcomes in patients with liposarcoma.

    Science.gov (United States)

    Panotopoulos, Joannis; Posch, Florian; Funovics, Philipp T; Willegger, Madeleine; Scharrer, Anke; Lamm, Wolfgang; Brodowicz, Thomas; Windhager, Reinhard; Ay, Cihan

    2016-03-01

    Low serum albumin levels and impaired kidney function have been associated with decreased survival in patients with a variety of cancer types. In a retrospective cohort study, we analyzed 84 patients with liposarcoma treated at from May 1994 to October 2011. Uni- and multivariable Cox proportional hazard models and competing risk analyses were performed to evaluate the association between putative biomarkers with disease-specific and overall survival. The median age of the study population was 51.7 (range 19.6-83.8) years. In multivariable analysis adjusted for AJCC tumor stage, serum creatinine was highly associated with disease-specific survival (Subdistribution Hazard ratio (SHR) per 1 mg/dl increase = 2.94; 95%CI 1.39-6.23; p = 0.005). High albumin was associated with improved overall and disease-specific survival (Hazard Ratio (HR) per 10 units increase = 0.50; 95%CI 0.26-0.95; p = 0.033 and SHR = 0.64; 95%CI 0.42-1.00; p = 0.049). The serum albumin-creatinine-ratio emerged to be associated with both overall and disease-specific survival after adjusting for AJCC tumor stage (HR = 0.95; 95%CI 0.92-0.99; p = 0.011 and SHR = 0.96; 95%CI 0.93-0.99; p = 0.08). Our study provides evidence for a tumor-stage-independent association between higher creatinine and lower albumin with worse disease-specific survival. Low albumin and a high albumin-creatinine-ratio independently predict poor overall survival. Our work identified novel prognostic biomarkers for prognosis of patients with liposarcoma. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Evaluation of formulas using the serum creatinine level to calculate the optimal dosage of carboplatin.

    Science.gov (United States)

    van Warmerdam, L J; Rodenhuis, S; ten Bokkel Huinink, W W; Maes, R A; Beijnen, J H

    1996-01-01

    Carboplatin is a chemotherapeutic agent frequently used in the treatment of various malignancies. An individual dosing strategy has been recommended to yield the most optimal exposure, expressed as the area under the concentration-time curve (AUC). The formula developed by Calvert et al. (dose = target-AUC x [GFR + 25]) can be used to achieve this. However, due to the inconvenient [51Cr]-ethylenediamine-tetraacetic acid ([51Cr]-EDTA)-based measurement of the glomerular filtration rate (GFR), its application in the clinic has thus far been limited. Chatelut and co-workers have recently proposed a formula to estimate carboplatin clearance using the serum creatinine concentration. We retrospectively tested the Chatelut equation and the Calvert formula using either the creatinine clearance based on 24-h urine collection or the creatinine clearance based on the formula of Cockcroft and Gault. The latter equations were shown to predict the carboplatin clearance reasonably well, although systematic overprediction and underprediction occurred. However, the formula proposed by Chatelut and co-workers had no significant bias and was precise. It is proposed that this formula be used to calculate the optimal carboplatin dosage after prospective validation has been performed.

  17. Serum creatinine may indicate risk of symptomatic intracranial hemorrhage after intravenous tissue plasminogen activator (IV tPA).

    Science.gov (United States)

    Marsh, Elisabeth B; Gottesman, Rebecca F; Hillis, Argye E; Urrutia, Victor C; Llinas, Rafael H

    2013-11-01

    Symptomatic intracranial hemorrhage (sICH) is a known complication following administration of intravenous tissue plasminogen activator (IV tPA) for acute ischemic stroke. sICH results in high rates of death or long-term disability. Our ability to predict its occurrence is important in clinical decision making and when counseling families. The initial National Institute of Neurological Disorders and Stroke (NINDS) investigators developed a list of relative contraindications to IV tPA meant to decrease the risk of subsequent sICH. To date, the impact of renal impairment has not been well studied. In the current study we evaluate the potential association between renal impairment and post-tPA intracranial hemorrhage (ICH). Admission serum creatinine and estimated glomerular filtration rate (eGFR) were recorded in 224 patients presenting within 4.5 hours from symptom onset and treated with IV tPA based on NINDS criteria. Neuroimaging was obtained 1 day post-tPA and for any change in neurologic status to evaluate for ICH. Images were retrospectively evaluated for hemorrhage by a board-certified neuroradiologist and 2 reviewers blinded to the patient's neurologic status. Medical records were reviewed retrospectively for evidence of neurologic decline indicating a "symptomatic" hemorrhage. sICH was defined as subjective clinical deterioration (documented by the primary neurology team) and hemorrhage on neuroimaging that was felt to be the most likely cause. Renal impairment was evaluated using both serum creatinine and eGFR in a number of ways: 1) continuous creatinine; 2) any renal impairment by creatinine (serum creatinine >1.0 mg/dL); 3) continuous eGFR; and 4) any renal impairment by eGFR (eGFR creatinine >1.0 mg/dL) was not associated with combined symptomatic and asymptomatic intracranial bleeding (p = 0.359); however, there was an adjusted 5.5-fold increased odds of sICH when creatinine was >1.0 mg/dL (95% confidence interval, 1.08-28.39), and the frequency of s

  18. Prognostic Importance of Low Admission Serum Creatinine Concentration for Mortality in Hospitalized Patients.

    Science.gov (United States)

    Thongprayoon, Charat; Cheungpasitporn, Wisit; Kittanamongkolchai, Wonngarm; Harrison, Andrew M; Kashani, Kianoush

    2017-05-01

    The study objective was to assess the association between low serum creatinine value at admission and in-hospital mortality in hospitalized patients. This was a retrospective single-center cohort study conducted at a tertiary referral hospital. All hospitalized adult patients between 2011 and 2013 who had an admission creatinine value available were identified for inclusion in this study. Admission creatinine value was categorized into 7 groups: ≤0.4, 0.5 to 0.6, 0.7 to 0.8, 0.9 to 1.0, 1.1 to 1.2, 1.3 to 1.4, and ≥1.5 mg/dL. The primary outcome was in-hospital mortality. Logistic regression analysis was performed to obtain the odds ratio of in-hospital mortality for the various admission creatinine levels, using a creatinine value of 0.7 to 0.8 mg/dL as the reference group in the analysis of all patients and female patients and of 0.9 to 1.0 mg/dL in the analysis of male patients because it was associated with the lowest in-hospital mortality. Of 73,994 included patients, 973 (1.3%) died in the hospital. The association between different categories of admission creatinine value and in-hospital mortality assumed a U-shaped distribution, with both low and high creatinine values associated with higher in-hospital mortality. After adjustment for age, sex, ethnicity, principal diagnosis, and comorbid conditions, very low creatinine value (≤0.4 mg/dL) was significantly associated with increased mortality (odds ratio, 3.29; 95% confidence interval, 2.08-5.00), exceeding the risk related to a markedly increased creatinine value of ≥1.5 mg/dL (odds ratio, 2.56; 95% confidence interval, 2.07-3.17). The association remained significant in the subgroup analysis of male and female patients. Low creatinine value at admission is independently associated with increased in-hospital mortality in hospitalized patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Serum uric acid to creatinine ratio: A predictor of incident chronic kidney disease in type 2 diabetes mellitus patients with preserved kidney function.

    Science.gov (United States)

    Gu, Liubao; Huang, Liji; Wu, Haidi; Lou, Qinglin; Bian, Rongwen

    2017-05-01

    Serum uric acid has shown to be a predictor of renal disease progression in most but not all studies. This study aims to test whether renal function-normalized serum uric acid is superior to serum uric acid as the predictor of incident chronic kidney disease in type 2 diabetes mellitus patients. In this study, 1339 type 2 diabetes mellitus patients with estimated glomerular filtration rate ⩾60 mL/min/1.73 m 2 and normouricemia were included. Renal function-normalized serum uric acid was calculated using serum uric acid/creatinine. Cox regression analysis was used to estimate the association between serum uric acid, renal function-normalized serum uric acid and incident chronic kidney disease. In total, 74 (5.53%) patients developed to chronic kidney disease 3 or greater during a median follow-up of 4 years, with older ages, longer diabetes duration and lower estimated glomerular filtration rate at baseline. The decline rate of estimated glomerular filtration rate was positively correlated with serum uric acid/creatinine ( r = 0.219, p uric acid ( r = 0.005, p = 0.858). Moreover, multivariate analysis revealed that serum uric acid was not an independent risk factor for incident chronic kidney disease ( p = 0.055), whereas serum uric acid to creatinine ratio was significantly associated with incident chronic kidney disease independently of potential confounders including baseline estimated glomerular filtration rate. serum uric acid to creatinine ratio might be a better predictor of incident chronic kidney disease in type 2 diabetes mellitus patients.

  20. Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment

    Science.gov (United States)

    O’Brien, Katie M.; Upson, Kristen; Cook, Nancy R.; Weinberg, Clarice R.

    2015-01-01

    Background Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. Objectives We compared adjustment methods, including novel approaches, using simulated case–control data. Methods Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. Results For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. Conclusions To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals. Citation O’Brien KM, Upson K, Cook NR, Weinberg CR. 2016. Environmental chemicals in urine and blood: improving methods for creatinine and lipid adjustment. Environ Health Perspect 124:220–227; http://dx.doi.org/10.1289/ehp.1509693 PMID:26219104

  1. A New Equation to Estimate Muscle Mass from Creatinine and Cystatin C.

    Directory of Open Access Journals (Sweden)

    Sun-wook Kim

    Full Text Available With evaluation for physical performance, measuring muscle mass is an important step in detecting sarcopenia. However, there are no methods to estimate muscle mass from blood sampling.To develop a new equation to estimate total-body muscle mass with serum creatinine and cystatin C level, we designed a cross-sectional study with separate derivation and validation cohorts. Total body muscle mass and fat mass were measured using dual-energy x-ray absorptiometry (DXA in 214 adults aged 25 to 84 years who underwent physical checkups from 2010 to 2013 in a single tertiary hospital. Serum creatinine and cystatin C levels were also examined.Serum creatinine was correlated with muscle mass (P < .001, and serum cystatin C was correlated with body fat mass (P < .001 after adjusting glomerular filtration rate (GFR. After eliminating GFR, an equation to estimate total-body muscle mass was generated and coefficients were calculated in the derivation cohort. There was an agreement between muscle mass calculated by the novel equation and measured by DXA in both the derivation and validation cohort (P < .001, adjusted R2 = 0.829, β = 0.95, P < .001, adjusted R2 = 0.856, β = 1.03, respectively.The new equation based on serum creatinine and cystatin C levels can be used to estimate total-body muscle mass.

  2. Blood urea nitrogen to serum creatinine ratio is an accurate predictor of outcome in diarrhea-associated hemolytic uremic syndrome, a preliminary study.

    Science.gov (United States)

    Keenswijk, Werner; Vanmassenhove, Jill; Raes, Ann; Dhont, Evelyn; Vande Walle, Johan

    2017-03-01

    Diarrhea-associated hemolytic uremic syndrome (D+HUS) is a common thrombotic microangiopathy during childhood and early identification of parameters predicting poor outcome could enable timely intervention. This study aims to establish the accuracy of BUN-to-serum creatinine ratio at admission, in addition to other parameters in predicting the clinical course and outcome. Records were searched for children between 1 January 2008 and 1 January 2015 admitted with D+HUS. A complicated course was defined as developing one or more of the following: neurological dysfunction, pancreatitis, cardiac or pulmonary involvement, hemodynamic instability, and hematologic complications while poor outcome was defined by death or development of chronic kidney disease. Thirty-four children were included from which 11 with a complicated disease course/poor outcome. Risk of a complicated course/poor outcome was strongly associated with oliguria (p = 0.000006) and hypertension (p = 0.00003) at presentation. In addition, higher serum creatinine (p = 0.000006) and sLDH (p = 0.02) with lower BUN-to-serum creatinine ratio (p = 0.000007) were significantly associated with development of complications. A BUN-to-sCreatinine ratio ≤40 at admission was a sensitive and highly specific predictor of a complicated disease course/poor outcome. A BUN-to-serum Creatinine ratio can accurately identify children with D+HUS at risk for a complicated course and poor outcome. What is Known: • Oliguria is a predictor of poor long-term outcome in D+HUS What is New: • BUN-to-serum Creatinine ratio at admission is an entirely novel and accurate predictor of poor outcome and complicated clinical outcome in D+HUS • Early detection of the high risk group in D+HUS enabling early treatment and adequate monitoring.

  3. Final report on CCQM-K80: Comparison of value-assigned CRMs and PT materials: Creatinine in human serum

    Science.gov (United States)

    Camara, Johanna E.; Duewer, David L.; Gasca Aragon, Hugo; Lippa, Katrice A.; Toman, Blaza

    2013-01-01

    The 2009 CCQM-K80 'Comparison of value-assigned CRMs and PT materials: creatinine in human serum' is the first in a series of key comparisons directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes. CCQM-K80 compared the assigned serum creatinine values of certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Six NMIs submitted 17 CRM materials for evaluation, all intended for sale to customers. These materials represent nearly all of the higher-order CRMs then available for this clinically important measurand. The certified creatinine mass fraction in the materials ranged from 3 mg/kg to 57 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analyst using isotope dilution liquid chromatography-mass spectrometry. The instrumental repeatability imprecision, expressed as a percent relative standard deviation, was 1.2%. Given the number of materials and the time required for each analysis, the measurements were made in two measurement campaigns ('runs'). In both campaigns, replicate analyses (two injections of one preparation separated in time) were made on each of two or three independently prepared aliquots from one randomly selected unit of each of the 17 materials. The mean value, between-campaign, between-aliquot and between-replicate variance components, standard uncertainty of the mean value, and the number of degrees of freedom associated with the standard uncertainty were estimated using a linear mixed model. Since several of the uncertainties estimated using this traditional frequentist approach were associated with a single degree of freedom, Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals, U95. Uncertainty-weighted generalized distance

  4. The Effect of Calcusol™ to the Plasma Free Radical and Serum Creatinin in Mus Musculus Nephrolithiasis Model

    Directory of Open Access Journals (Sweden)

    A’liyatur Rosyidah

    2013-09-01

    Full Text Available Calcusol™ is a traditional medicine (jamu made from Tempuyung (Sonchus arvensis extract and is usually used for cure kidney stone disease. However, there has not been any studies which investigate the its mechanism. The aim of this study is to know the effect of Calcusol™ to the plasma free radical and serum creatinin of Mus musculus model for renal calcium-oxalate accumulation. This study is carried out by administration of Porang (Amorphophallus muelleri tuber flour for 3 months with the doses 6 mg/100g BW to induce renal calcium oxalate accumulation and Calcusol™ treatment for 7 days with the doses of 3.3mg/g BW. Group I was used as a control group. Group II was only given porang every day for 3 months. Group III was only given Calcusol™ for 7 days. Group IV were given porang for 3 months then given Calcusol™ for 7 days. Group V were given porang and Calcusol™ simultaneously for 3 months. Porang and CalcusolTM is administrated orally. Blood was collected from the tail of the animal for serum creatinin test and plasma free radical test using TBARS method. The data was analyzed using ANOVA followed by Tukey HSD to compare the means employing SPSS 16.0 for windows. The result of the research shows that the treatment Calcusol™ on mice model for renal calcium oxalate accumulation. The content of MDA at group I, group II, group III, group IV and group V, respectivelyis 0.81±0.5 mg/ml; 2.63±0.8 mg/ml; 0.56±0.5 mg/ml; 2.09±0.9 mg/ml and 0.17±0.17 mg/ml. The content of serum creatinine are 0.15±0.04 mg/dL; 0.13±0.03 mg/dL; 0.12±0.08 mg/dL; 0.11±0.016 mg/dL and 0.14±0.015 mg/dL at group I, group II, group III, Group IV, and group V respectively. This indicates that Calcusol™ decreases plasma free radical production during renal stone formation, while serum creatinin reduced but not significantly changed. Calcusol™ has an effect to decrease free radical during renalstone formation inmice model for calcium oxalate accumulation

  5. Comparison of Glomerular Filtration Rate Estimation from Serum Creatinine and Cystatin C in HNF1A-MODY and Other Types of Diabetes.

    Science.gov (United States)

    Szopa, Magdalena; Kapusta, Maria; Matejko, Bartlomiej; Klupa, Tomasz; Koblik, Teresa; Kiec-Wilk, Beata; Borowiec, Maciej; Malecki, Maciej T

    2015-01-01

    We previously showed that in HNF1A-MODY the cystatin C-based glomerular filtration rate (GFR) estimate is higher than the creatinine-based estimate. Currently, we aimed to replicate this finding and verify its clinical significance. The study included 72 patients with HNF1A-MODY, 72 with GCK-MODY, 53 with type 1 diabetes (T1DM), 70 with type 2 diabetes (T2DM), and 65 controls. Serum creatinine and cystatin C levels were measured. GFR was calculated from creatinine and cystatin C using the CKD-EPI creatinine equation (eGRF-cr) and CKD-EPI cystatin C equation (eGFR-cys), respectively. Cystatin C levels were lower (p MODY, GCK-MODY, and the controls (p = 0.004; p = 0.003; p MODY patients are higher compared to eGFR-cr. Some other differences were also described in diabetic groups. However, none of them appears to be clinically relevant.

  6. Validation of daily urinary creatinine excretion measurement by muscle-creatinine equivalence.

    Science.gov (United States)

    Iacone, Roberto; D'Elia, Lanfranco; Guida, Bruna; Barbato, Antonio; Scanzano, Clelia; Strazzullo, Pasquale

    2018-02-09

    Twenty-four-hour urinary creatinine excretion (24hUCrE) is strongly correlated with skeletal muscle mass (SMM). This study suggests how to exploit the power of the SMM-24hUCrE correlation to assess the accuracy of 24hUCrE measurement. Four hundred and sixty-six men, a subgroup of participants in the 2002-2004 follow-up examination of the Olivetti Heart Study, performed a 24-h urine collection to measure 24hUCrE and underwent bioelectrical impedance analysis to evaluate SMM. Linear regression analysis between 24hUCrE and SMM was used to calculate the muscle-creatinine equivalence and to develop an equation to predict the 24hUCrE depending on SMM. The accuracy of the 24hUCrE measurement was assessed using the change in the SMM-24hUCrE correlation coefficient upon variation in the percentage deviation (%D) between the measured and predicted 24hUCrE. The calculated muscle-creatinine equivalence was 1 g of 24hUCrE = 22.73 kg of SMM. The %Ds and the corresponding SMM-24hUCrE correlation coefficients were as follows: %D = 3.0, r = .997; %D = 4.7, r = .989; %D = 8.1, r = .963; %D = 10.5, r = .940; %D = 12.6, r = .909; %D = 18.9, r = .825; %D = 25.8, r = .707; %D = 33.5, r = .595; %D = 41.4, r = .453. The increase in %D corresponds to a reduced correlation between muscle mass and creatinine excretion, which indicated a poor performance in the measurement of the 24hUCrE. For studies on single individuals, where small variations in 24hUCrE could be significant, a %D up to 12.6% is suggested; on the other hand, a wider %D interval could be acceptable for population studies. © 2018 Wiley Periodicals, Inc.

  7. Antimalarial drug induced decrease in creatinine clearance

    NARCIS (Netherlands)

    Landewé, R. B.; Vergouwen, M. S.; Goeei The, S. G.; van Rijthoven, A. W.; Breedveld, F. C.; Dijkmans, B. A.

    1995-01-01

    To confirm the antimalarial drug induced increase of creatinine to determine the factors contributing to this effect. Patients with rheumatoid arthritis (RA) (n = 118) who have used or still use antimalarials (chloroquine or hydroxychloroquine). Serum creatinines prior to antimalarials and serum

  8. Correlation between glomerular filtration rate with gamma camera and estimated serum creatinine clearance from Cockcroft and Gault's formula

    International Nuclear Information System (INIS)

    Bhushan, Shivanand; Kumar, Rajesh

    2012-01-01

    The purpose of the present study is to find out the correlation between the glomerular filtration rate (GFR by Gates gamma camera method) and serum creatinine clearance (SCrCl by Cockcroft and Gault's method) within ± 3 weeks’ time difference. Study design retrospectively in 59 patients with serum creatinine value calculated for SCrCl with Cockcroft and Gault's formula as an index parameter for kidney function underwent the 99m-Technitium labeled Di-ethyl Triamine Penta Acetic Acid (99mTc-DTPA) renogram with ECIL planar gamma camera. All data of 59 patients has been divided into Group- I, II, and III based on the time difference of serum creatinine test from 99mTc-DTPA renal GFR tests performed on the same subjects. Serum Creatinine test was carried out within ± 3 days, between ± 4 days and ± 7 days, and between ± 8 days and ± 21 days from the DTPA GFR Test performed in the Group-I, II, and III respectively. Correlation coefficient of Group-I (n = 15) patients showed 0.8198 and P value < 0.001 for GFR and S. Creatinine within ± 3 days. Group-II (n = 17) and Group-III (n = 27) patients having correlation coefficient 0.6194 and 0.589 and P value <0.01 respectively, within ± 21 days. The two methods gave almost identical estimate of GFR even at 3 weeks interval. Study concludes that SCrCl using Cockcroft and Gault's formula could serve as an instant, easy, and reliable method for assessing kidney function. SCrCl with Cockcroft and Gault's formula is more useful for rapid estimation of global GFR for those patients who are not accessible to DTPA renogram with gamma camera. Correlation can be established further with the prospective study in various renal pathophysiological conditions

  9. Low Body Mass Index, Serum Creatinine, and Cause of Death in Patients Undergoing Percutaneous Coronary Intervention.

    Science.gov (United States)

    Goel, Kashish; Gulati, Rajiv; Reeder, Guy S; Lennon, Ryan J; Lewis, Bradley R; Behfar, Atta; Sandhu, Gurpreet S; Rihal, Charanjit S; Singh, Mandeep

    2016-10-31

    Low body mass index (BMI) and serum creatinine are surrogate markers of frailty and sarcopenia. Their relationship with cause-specific mortality in elderly patients undergoing percutaneous coronary intervention is not well studied. We determined long-term cardiovascular and noncardiovascular mortality in 9394 consecutive patients aged ≥65 years who underwent percutaneous coronary intervention from 2000 to 2011. BMI and serum creatinine were divided into 4 categories. During a median follow-up of 4.2 years (interquartile range 1.8-7.3 years), 3243 patients (33.4%) died. In the multivariable model, compared with patients with normal BMI, patients with low BMI had significantly increased all-cause mortality (hazard ratio [HR] 1.4, 95% CI 1.1-1.7), which was related to both cardiovascular causes (HR 1.4, 95% CI 1.0-1.8) and noncardiovascular causes (HR 1.4, 95% CI 1.06-1.9). Compared with normal BMI, significant reduction was noted in patients who were overweight and obese in terms of cardiovascular mortality (overweight: HR 0.77, 95% CI 0.67-0.88; obese: HR 0.80, 95% CI 0.70-0.93) and noncardiovascular mortality (overweight: HR 0.85, 95% CI 0.74-0.97; obese: HR 0.82, 95% CI 0.72-0.95). In a multivariable model, in patients with normal BMI, low creatinine (≤0.70 mg/dL) was significantly associated with increased all-cause mortality (HR 1.8, 95% CI 1.3-2.5) and cardiovascular mortality (HR 2.3, 95% CI 1.4-3.8) compared with patients with normal creatinine (0.71-1.0 mg/dL); however, this was not observed in other BMI categories. We identified a new subgroup of patients with low serum creatinine and normal BMI that was associated with increased all-cause mortality and cardiovascular mortality in elderly patients undergoing percutaneous coronary intervention. Low BMI was associated with increased cardiovascular and noncardiovascular mortality. Nutritional support, resistance training, and weight-gain strategies may have potential roles for these patients undergoing

  10. Trends in serum creatinine testing in Oxfordshire, UK, 1993-2013: a population-based cohort study.

    Science.gov (United States)

    Oke, Jason; Shine, Brian; McFadden, Emily; Stevens, Richard; Lasserson, Daniel; Perera, Rafael

    2015-12-16

    To determine how many kidney function tests are done, on whom, how frequently they are performed and how they have changed over time. Retrospective study of all serum creatinine, urine albumin and urine creatinine tests. Primary and secondary care in Oxfordshire from 1993 to 2013. Unselected population of 1,220,447 people. The total number of creatinine and urinary protein tests ordered from primary and secondary care and the number of tests per year stratified by categories of estimated glomerular filtration rate (eGFR). The frequency of testing in patients having their kidney function monitored. Creatinine requests from primary care increased steadily from 1997 and exceeded 220,000 requests in 2013. Tests corresponding to normal kidney function (eGFR >60/mL/min/1.73 m(2)) constituted 59% of all kidney function tests in 1993 and accounted for 83% of all tests in 2013. Test corresponding to chronic kidney disease (CKD) stages 3-5 declined after 2007. Reduced kidney function, albuminuria, male gender, diabetes and age were independently associated with more frequent monitoring. For a female patient between 61 and 80 years and with stage 3a CKD, the average number of serum creatinine tests (95% CI) was 3.23/year (3.19 to 3.26) and for a similar woman with diabetes, the average number of tests was 5.50 (5.44 to 5.56) tests per year. There has been a large increase in the number of kidney function tests over the past two decades. However, we found little evidence that this increase is detecting more CKD. Tests are becoming more frequent in people with and without evidence of renal impairment. Future work using a richer data source could help unravel the underlying reasons for the increased testing and determine how much is necessary and useful. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  11. Mechanisms Underpinning Increased Plasma Creatinine Levels in Patients Receiving Vemurafenib for Advanced Melanoma

    Science.gov (United States)

    Hurabielle, Charlotte; Pillebout, Evangéline; Stehlé, Thomas; Pagès, Cécile; Roux, Jennifer; Schneider, Pierre; Chevret, Sylvie; Chaffaut, Cendrine; Boutten, Anne; Mourah, Samia; Basset-Seguin, Nicole; Vidal-Petiot, Emmanuelle; Lebbé, Céleste; Flamant, Martin

    2016-01-01

    Context Serum creatinine has been reported to increase in patients receiving Vemurafenib, yet neither the prevalence nor the mechanism of this adverse event are known. Objective We aimed to evaluate the frequency and the mechanisms of increases in plasma creatinine level in patients receiving Vemurafenib for advanced melanoma. Methods We performed a retrospective monocentric study including consecutive patients treated with Vemurafenib for an advanced melanoma. We collected clinical and biological data concerning renal function before introduction of Vemurafenib and in the course of monthly follow-up visits from March 2013 to December 2014. Cystatin C-derived glomerular filtration rate was evaluated before and after Vemurafenib initiation, as increase in serum cystatin C is specific to a decrease in the glomerular filtration rate. We also performed thorough renal explorations in 3 patients, with measurement of tubular secretion of creatinine before and after Vemurafenib initiation and a renal biopsy in 2 patients. Results 70 patients were included: 97% of them displayed an immediate, and thereafter stable, increase in creatinine (+22.8%) after Vemurafenib initiation. In 44/52 patients in whom Vemurafenib was discontinued, creatinine levels returned to baseline. Serum cystatin C increased, although proportionally less than serum creatinine, showing that creatinine increase under vemurafenib was indeed partly due to a renal function impairment. In addition, renal explorations demonstrated that Vemurafenib induced an inhibition of creatinine tubular secretion. Conclusion Thus, Vemurafenib induces a dual mechanism of increase in plasma creatinine with both an inhibition of creatinine tubular secretion and slight renal function impairment. However, this side effect is mostly reversible when Vemurafenib is discontinued, and should not lead physicians to discontinue the treatment if it is effective. PMID:26930506

  12. Serum creatinine and cystatin C provide conflicting evidence of acute kidney injury following acute ingestion of potassium permanganate and oxalic acid.

    Science.gov (United States)

    Wijerathna, Thilini Madushanka; Gawarammana, Indika Bandara; Dissanayaka, Dhammika Menike; Palanagasinghe, Chathura; Shihana, Fathima; Dassanayaka, Gihani; Shahmy, Seyed; Endre, Zoltan Huba; Mohamed, Fahim; Buckley, Nicholas Alan

    2017-11-01

    Acute kidney injury (AKI) is common following deliberate self-poisoning with a combination washing powder containing oxalic acid (H 2 C 2 O 4 ) and potassium permanganate (KMnO 4 ). Early and rapid increases in serum creatinine (sCr) follow severe poisoning. We investigated the relationship of these increases with direct nephrotoxicity in an ongoing multicenter prospective cohort study in Sri Lanka exploring AKI following poisoning. Multiple measures of change in kidney function were evaluated in 48 consenting patients who had serial sCr and serum cystatin C (sCysC) data available. Thirty-eight (38/48, 79%) patients developed AKI (AKIN criteria). Twenty-eight (58%) had AKIN stage 2 or 3. Initial increases in urine creatinine (uCr) excretion were followed by a substantial loss of renal function. The AKIN stage 2 and 3 (AKIN2/3) group had very rapid rises in sCr (a median of 118% at 24 h and by 400% at 72 h post ingestion). We excluded the possibility that the rapid rise resulted from the assay used or muscle damage. In contrast, the average sCysC increase was 65% by 72 h. In most AKI, sCysC increases to the same extent but more rapidly than sCr, as sCysC has a shorter half-life. This suggests either a reduction in Cystatin C production or, conversely, that the rapid early rise of sCr results from increased production of creatine and creatinine to meet energy demands following severe oxidative stress mediated by H 2 C 2 O 4 and KMnO 4 . Increased early creatinine excretion supports the latter explanation, since creatinine excretion usually decreases transiently in AKIN2/3 from other causes.

  13. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  14. Mechanisms Underlying Early Rapid Increases in Creatinine in Paraquat Poisoning

    Science.gov (United States)

    Mohamed, Fahim; Endre, Zoltan; Jayamanne, Shaluka; Pianta, Timothy; Peake, Philip; Palangasinghe, Chathura; Chathuranga, Umesh; Jayasekera, Kithsiri; Wunnapuk, Klintean; Shihana, Fathima; Shahmy, Seyed; Buckley, Nicholas

    2015-01-01

    Background Acute kidney injury (AKI) is common after severe paraquat poisoning and usually heralds a fatal outcome. The rapid large increases in serum creatinine (Cr) exceed that which can be explained by creatinine kinetics based on loss of glomerular filtration rate (GFR). Methods and Findings This prospective multi-centre study compared the kinetics of two surrogate markers of GFR, serum creatinine and serum cystatin C (CysC), following paraquat poisoning to understand and assess renal functional loss after paraquat poisoning. Sixty-six acute paraquat poisoning patients admitted to medical units of five hospitals were included. Relative changes in creatinine and CysC were monitored in serial blood and urine samples, and influences of non-renal factors were also studied. Results Forty-eight of 66 patients developed AKI (AKIN criteria), with 37 (56%) developing moderate to severe AKI (AKIN stage 2 or 3). The 37 patients showed rapid increases in creatinine of >100% within 24 hours, >200% within 48 hours and >300% by 72 hours and 17 of the 37 died. CysC concentration increased by 50% at 24 hours in the same 37 patients and then remained constant. The creatinine/CysC ratio increased 8 fold over 72 hours. There was a modest fall in urinary creatinine and serum/urine creatinine ratios and a moderate increase in urinary paraquat during first three days. Conclusion Loss of renal function contributes modestly to the large increases in creatinine following paraquat poisoning. The rapid rise in serum creatinine most probably represents increased production of creatine and creatinine to meet the energy demand following severe oxidative stress. Minor contributions include increased cyclisation of creatine to creatinine because of acidosis and competitive or non-competitive inhibition of creatinine secretion. Creatinine is not a good marker of renal functional loss after paraquat poisoning and renal injury should be evaluated using more specific biomarkers of renal injury

  15. Serum creatinine level: a supplemental index to distinguish Duchenne muscular dystrophy from Becker muscular dystrophy.

    Science.gov (United States)

    Zhang, Huili; Zhu, Yuling; Sun, Yiming; Liang, Yingyin; Li, Yaqin; Zhang, Yu; Deng, Langhui; Wen, Xingxuan; Zhang, Cheng

    2015-01-01

    To improve assessment of dystrophinopathy, the aim of this study was to identify whether serum creatinine (Crn) level reflects disease severity. Biochemical, Vignos score, and genetic data were collected on 212 boys with dystrophinopathy. Serum Crn level had a strong inverse correlation with Vignos score by simple correlation (r = -0.793) and partial correlation analysis after adjustment for age, height, and weight (r = -0.791; both P Becker muscular dystrophy (BMD) patients than Duchenne muscular dystrophy (DMD) patients at ages 4, 5, 7, and 9 yr (all P < 0.0125). After adjusting for age, height, and weight, BMD patients still had a significantly higher serum Crn level than DMD patients (β = 7.140,  t = 6.277,  P < 0.01). Serum Crn level reflected disease severity and may serve as a supplemental index to distinguish DMD from BMD in clinical practice.

  16. Age- and sex-specific reference limits for creatinine, cystatin C and the estimated glomerular filtration rate.

    Science.gov (United States)

    Hannemann, Anke; Friedrich, Nele; Dittmann, Kathleen; Spielhagen, Christin; Wallaschofski, Henri; Völzke, Henry; Rettig, Rainer; Endlich, Karlhans; Lendeckel, Uwe; Stracke, Sylvia; Nauck, Matthias

    2011-11-14

    Early detection of patients with chronic kidney disease is of great importance. This study developed reference limits for serum creatinine and serum cystatin C concentrations and for the estimated glomerular filtration rate (eGFR) in healthy subjects from the general population aged 25-65 years. This study defined a reference population including 985 subjects from the first follow-up of the Study of Health in Pomerania. Serum creatinine was measured with a modified kinetic Jaffé method. Serum cystatin C was measured with a nephelometric assay. The eGFR was calculated from serum creatinine according to the Cockcroft-Gault (eGFR(CG)) and the Modification of Diet in Renal Disease (eGFR(MDRD)) equation, respectively, as well as from serum cystatin C according to the formula by Larsson (eGFR(Larsson)). Non-parametric quantile regression was used to estimate the reference limits. For serum creatinine and serum cystatin C the 95th percentile and for eGFR(CG), eGFR(MDRD) and eGFR(Larsson) the 5th percentile were selected as reference limits. All data was weighted to reflect the age- and sex-structure of the German population in 2008. The reference limits for serum creatinine (men: 1.11-1.23 mg/dL; women: 0.93-1.00 mg/dL) and serum cystatin C levels (men: 0.92-1.04 mg/L; women: 0.84-1.02 mg/L) increased with advancing age. The reference limits for eGFR decreased with increasing age (eGFR(CG) men: 106.0-64.7 mL/min, women 84.4-57.9 mL/min; eGFR(MDRD) men: 82.5-62.2 mL/min/1.73 m², women 75.0-58.2 mL/min/1.73 m²; eGFR(Larsson) men: 85.5-72.9 mL/min, women 94.5-75.7 mL/min). This study presents age- and sex-specific reference limits for five measures of renal function based on quantile regression models.

  17. Doubling of serum creatinine and the risk of cardiovascular outcomes in patients with chronic kidney disease and type 2 diabetes mellitus: a cohort study

    Directory of Open Access Journals (Sweden)

    Schneider C

    2016-06-01

    Full Text Available Cornelia Schneider,1,2 Blai Coll,3 Susan S Jick,4 Christoph R Meier1,2,4 1Basel Pharmacoepidemiology Unit, Division of Clinical Pharmacy and Epidemiology, Department of Pharmaceutical Sciences, University of Basel, Basel, Switzerland; 2Hospital Pharmacy, University Hospital Basel, Basel, Switzerland; 3Renal Development, AbbVie, North Chicago, IL, USA; 4Boston Collaborative Drug Surveillance Program, Boston University School of Public Health, MA, USA Background: Doubling of serum creatinine is often used as a marker for worsening kidney function in nephrology trials. Most people with chronic kidney disease die of other causes before reaching end-stage renal disease. We were interested in the association between doubling of serum creatinine and the risk of a first-time diagnosis of angina pectoris, congestive heart failure (CHF, myocardial infarction (MI, stroke, or transient ischemic attack in patients with chronic kidney disease and with diagnosed type 2 diabetes mellitus. Methods: We identified all adult patients registered in the “Clinical Practice Research Datalink” between 2002 and 2011 with incident chronic kidney disease and type 2 diabetes mellitus and did a cohort study with a Cox proportional hazard analysis. Results: We identified in total 27,811 patients, 693 developed angina pectoris, 1,069 CHF, 508 MI, 970 stroke, and 578 transient ischemic attacks. Patients whose serum creatinine doubled during follow-up had increased risks of CHF (hazard ratio [HR] 2.98, 95% confidence interval [CI] 2.27–3.89, MI (HR 2.53, 95% CI 1.62–3.96, and stroke (HR 1.93, 95% CI 1.38–2.69, as compared with patients whose serum creatinine did not double. The relative risks of angina pectoris (HR 1.18, 95% CI 0.66–2.10 or a transient ischemic attack (HR 1.32, 95% CI 0.78–2.22 were similar in both groups. Conclusion: Diabetic patients with a doubling of serum creatinine were at an increased risk of CHF, MI, or stroke, compared with diabetic

  18. Serum creatinine and creatinine clearance for predicting plasma methotrexate concentrations after high-dose methotrexate chemotherapy for the treatment for childhood lymphoblastic malignancies.

    Science.gov (United States)

    Xu, Wei-qun; Zhang, Ling-yan; Chen, Xue-ying; Pan, Bin-hua; Mao, Jun-qing; Song, Hua; Li, Jing-yuang; Tang, Yong-min

    2014-01-01

    Monitoring of plasma methotrexate (MTX) concentrations allows for therapeutic adjustments in treating childhood acute lymphoblastic leukemia (ALL) or non-Hodgkin lymphoma (NHL) with high-dose MTX (HDMTX). We tested the hypothesis that assessment of creatinine clearance (CrCl) and/or serum Cr may be a suitable means of monitoring plasma MTX concentrations. All children in the study had ALL or NHL, were in complete remission, and received HDMTX (3 or 5 g/m(2))+leucovorin. Plasma MTX concentrations were measured at 24, 48, and 96 h. CrCl was determined at 24 and 48 h. Correlations between 24- and 48-h plasma MTX concentrations and CrCl and serum Cr concentrations were determined. CrCl and serum Cr concentrations were compared over time between children who had delayed and non-delayed MTX elimination. A total of 105 children were included. There were significant negative correlations between CrCl at 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were significant positive correlations between serum Cr concentrations at both 24 and 48 h and plasma MTX concentrations at 24 (both p < 0.001) and 48 h (both p < 0.001). There were 88 (30.2 %) instances of elimination delay. Children with elimination delay had significantly lower CrCl and higher Cr concentrations at 24 and 48 h compared with children without elimination delay (all p < 0.05). Our findings suggest that, with further refinement, assessment of renal function may be a useful means of monitoring plasma MTX concentrations during HDMTX for ALL and NHL.

  19. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  20. Role of MELD score and serum creatinine as prognostic tools for the development of acute kidney injury after liver transplantation.

    Directory of Open Access Journals (Sweden)

    Thiago Gomes Romano

    Full Text Available BACKGROUND: The role of the Model for End-Stage Liver Disease (MELD score in predicting complications, such as Acute Kidney Injury (AKI, after orthotopic liver transplantation (OLT has yet to be evaluated and serum creatinine may be too heavily weighted in the existing MELD formula, since it has many pitfalls in cirrhotic patients. METHODS: Retrospective data of the perioperative period from consecutive adult OLTs performed from January to December 2009 were recorded. Univariate and multivariate analysis were performed to analyze the risk factors for AKI and mortality after OLT. RESULTS: There were 114 OLTs performed in the study period, 22 (19,2% were submitted to dialysis prior OLT and were excluded from the analysis for AKI. The median age was 52 years and 66% were male. Median creatinine value was 0.85mg/dL and MELD was 19. Fifty-two of the 92 patients (56,5% developed AKI in the first 72 hours after OLT. The only independent risk factor for AKI was calculated MELD and when the components of the MELD score were analyzed, INR had a much stronger impact in predicting AKI then serum creatinine. Overall mortality rate was 32,5% and anesthesia duration was the only variable associated with higher mortality rate. CONCLUSIONS: Although MELD score seems to have a good performance in predicting AKI after OLT, serum creatinine had no impact on its prediction despite its importance on MELD calculation. Modifying the MELD score, which could include novel AKI biomarkers, may improve its prognostic accuracy and provide a better tool for public health planning.

  1. Reduced Production of Creatinine Limits Its Use as Marker of Kidney Injury in Sepsis

    OpenAIRE

    Doi, Kent; Yuen, Peter S.T.; Eisner, Christoph; Hu, Xuzhen; Leelahavanichkul, Asada; Schnermann, Jürgen; Star, Robert A.

    2009-01-01

    Although diagnosis and staging of acute kidney injury uses serum creatinine, acute changes in creatinine lag behind both renal injury and recovery. The risk for mortality increases when acute kidney injury accompanies sepsis; therefore, we sought to explore the limitations of serum creatinine in this setting. In mice, induction of sepsis by cecal ligation and puncture in bilaterally nephrectomized mice increased markers of nonrenal organ injury and serum TNF-α. Serum creatinine, however, was ...

  2. Variation in Serum Creatinine Level Is Correlated to Risk of Type 2 Diabetes

    OpenAIRE

    Jun Sung Moon; Ji Eun Lee; Ji Sung Yoon

    2013-01-01

    Background Skeletal muscle is well established as a major target organ of insulin action, and is associated with the pathogenesis of type 2 diabetes. Therefore, we attempted to determine whether a variation in serum creatinine is related to the development of type 2 diabetes and other risk factors for diabetes. Methods A total of 2,676 nondiabetic subjects with stable and normal renal function (estimated glomerular filtration rate >60 mL/min/1.73 m2) were followed up for approximately 4.5 yea...

  3. Comparison of the Efficacy of Serum Creatinine and Microalbuminuria in Early Diagnosis of Renal Injury in Asphyxiated Infants in Calabar, Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Sunny Oteikwu Ochigbo

    2017-06-01

    Full Text Available Background: Microalbuminuria and serum creatinine are the specific markers of acute renal injury. Perinatal asphyxia is responsible for 50% of all neonatal deaths and nonoliguric acute renal injuryis one of its complications. This study was undertaken to determine the efficacy of serum creatinine and microalbuminuria for early diagnosis of renal injury in severely asphyxiated neonates in Calabar, Nigeria.Methods: This prospective cross-sectional study was performed among severely asphyxiated newborns admitted into the neonatal wards of the University of Calabar Teaching Hospital (UCTH. Standard methods for the determination of blood urea and electrolyte were executed. Micral-test strips have been applied using urine dipstick and the result of the test was negative only for albumin. The developed colors have been compared five minutes after the first test.Results: Fifty full-term newborns were enrolled and their serum electrolytes, creatinine and the creatinine clearance were essentially normal. Six neonates demonstrated positive results in the microalbominuria assessment, while the rest were negative in this regard. The test has 0% sensitivity and 100% specificity, while the positive and negative predictive values were 0% and 88%, respectively.Conclusion: Microalbuminuria is not a useful marker for early diagnosis of acute renal failure in the newborns with severe prenatal asphyxia, but further studies are recommended.

  4. The Complexities of Interpreting Reversible Elevated Serum Creatinine Levels in Drug Development: Does a Correlation with Inhibition of Renal Transporters Exist?

    Science.gov (United States)

    Chu, Xiaoyan; Bleasby, Kelly; Chan, Grace Hoyee; Nunes, Irene; Evers, Raymond

    2016-09-01

    In humans, creatinine is formed by a multistep process in liver and muscle and eliminated via the kidney by a combination of glomerular filtration and active transport. Based on current evidence, creatinine can be taken up into renal proximal tubule cells by the basolaterally localized organic cation transporter 2 (OCT2) and the organic anion transporter 2, and effluxed into the urine by the apically localized multidrug and toxin extrusion protein 1 (MATE1) and MATE2K. Drug-induced elevation of serum creatinine (SCr) and/or reduced creatinine renal clearance is routinely used as a marker for acute kidney injury. Interpretation of elevated SCr can be complex, because such increases can be reversible and explained by inhibition of renal transporters involved in active secretion of creatinine or other secondary factors, such as diet and disease state. Distinction between these possibilities is important from a drug development perspective, as increases in SCr can result in the termination of otherwise efficacious drug candidates. In this review, we discuss the challenges associated with using creatinine as a marker for kidney damage. Furthermore, to evaluate whether reversible changes in SCr can be predicted prospectively based on in vitro transporter inhibition data, an in-depth in vitro-in vivo correlation (IVIVC) analysis was conducted for 16 drugs with in-house and literature in vitro transporter inhibition data for OCT2, MATE1, and MATE2K, as well as total and unbound maximum plasma concentration (Cmax and Cmax,u) data measured in the clinic. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  5. Amyotrophic lateral sclerosis outcome measures and the role of albumin and creatinine: a population-based study.

    Science.gov (United States)

    Chiò, Adriano; Calvo, Andrea; Bovio, Giacomo; Canosa, Antonio; Bertuzzo, Davide; Galmozzi, Francesco; Cugnasco, Paolo; Clerico, Marinella; De Mercanti, Stefania; Bersano, Enrica; Cammarosano, Stefania; Ilardi, Antonio; Manera, Umberto; Moglia, Cristina; Sideri, Riccardo; Marinou, Kalliopi; Bottacchi, Edo; Pisano, Fabrizio; Cantello, Roberto; Mazzini, Letizia; Mora, Gabriele

    2014-09-01

    There is an urgent need to identify reliable biomarkers of amyotrophic lateral sclerosis (ALS) progression for clinical practice and pharmacological trials. To correlate several hematological markers evaluated at diagnosis with ALS outcome in a population-based series of patients (discovery cohort) and replicate the findings in an independent validation cohort from an ALS tertiary center. The discovery cohort included 712 patients with ALS from the Piemonte and Valle d'Aosta Register for Amyotrophic Lateral Sclerosis from January 1, 2007, to December 31, 2011. The validation cohort comprised 122 patients with ALS at different stages of disease consecutively seen at an ALS tertiary center between January 1, 2007, and January 1, 2009. The following hematological factors were investigated and correlated with survival: total leukocytes, neutrophils, lymphocytes, monocytes, glucose, creatinine, uric acid, albumin, bilirubin, total cholesterol, triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, creatine kinase, thyroid-stimulating hormones, and erythrocyte sedimentation rate; all analyses were performed separately by sex. The patient of the validation cohort also underwent bioelectrical impedance analysis for the calculation of fat-free mass. Of the 712 patients in the examined period in Piemonte and Valle d'Aosta, 638 (89.6%) were included in the study. Only serum albumin (men: ≤ 4.3 vs >4.3 mg/dL, P 4.3 mg/dL, P creatinine levels (men: ≤ 0.82 vs >0.82 mg/dL, P = .004; women: ≤ 0.65 vs >0.05 mg/dL, P = .004) and lymphocyte count (men: ≤ 1700 vs >1700/μL, P = .04; women: ≤ 1700 vs >1700/μL, P = .02) were significantly associated with ALS outcome in both sexes with a dose-response effect (better survival with increasing levels). These findings were confirmed in the validation cohort. Multivariable analysis showed that serum albumin (men: hazard ratio [HR], 1.39; 95% CI, 1.05-1.90; P = .02; women: HR, 1.73; 95

  6. Serum Creatinine Level: A Supplemental Index to Distinguish Duchenne Muscular Dystrophy from Becker Muscular Dystrophy

    Directory of Open Access Journals (Sweden)

    Huili Zhang

    2015-01-01

    Full Text Available Background. To improve assessment of dystrophinopathy, the aim of this study was to identify whether serum creatinine (Crn level reflects disease severity. Methods. Biochemical, Vignos score, and genetic data were collected on 212 boys with dystrophinopathy. Results. Serum Crn level had a strong inverse correlation with Vignos score by simple correlation (r=-0.793 and partial correlation analysis after adjustment for age, height, and weight (r=-0.791; both P<0.01. Serum Crn level was significantly higher in patients with in-frame than out-of-frame mutations (Z=-4.716, P<0.01 and in Becker muscular dystrophy (BMD patients than Duchenne muscular dystrophy (DMD patients at ages 4, 5, 7, and 9 yr (all P<0.0125. After adjusting for age, height, and weight, BMD patients still had a significantly higher serum Crn level than DMD patients (β=7.140, t=6.277, P<0.01. Conclusions. Serum Crn level reflected disease severity and may serve as a supplemental index to distinguish DMD from BMD in clinical practice.

  7. Transporters affecting biochemical test results: Creatinine-drug interactions.

    Science.gov (United States)

    Chu, X; Bleasby, K; Chan, G H; Nunes, I; Evers, R

    2016-11-01

    Creatinine is eliminated by the kidneys through a combination of glomerular filtration and active transport. Drug-induced increases in serum creatinine (SCr) and/or reduced creatinine renal clearance are used as a marker for acute kidney injury. However, inhibition of active transport of creatinine can result in reversible and, therefore, benign increases in SCr levels. Herein, the transporters involved in creatinine clearance are discussed, in addition to limitations of using creatinine as a biomarker for kidney damage. © 2016 American Society for Clinical Pharmacology and Therapeutics.

  8. Ethamsylate (Dicynone) interference in determination of serum creatinine, uric acid, triglycerides, and cholesterol in assays involving the Trinder reaction; in vivo and in vitro.

    Science.gov (United States)

    Dastych, Milan; Wiewiorka, Ondrej; Benovská, Miroslava

    2014-01-01

    The aim of our research was the quantification of interfering properties of the haemostatic drug Dicynone (ethamsylate) in serum creatinine, uric acid, cholesterol, and triglyceride assays using the Trinder reaction. Blood from patients was collected before and 15 minutes after administration of 500 mg Dicynone dose i.v. and the above mentioned analytes were quantified using Roche assays (Cobas 8000). In our in vitro experiment, we measured concentrations of the analytes in pooled serum aliquots with final concentrations of Dicynone additions 0, 30, 60, 150, and 300 mg/L. Aliquots with 60 mg/L Dicynone were also measured at 2, 6, and 8 hours after initial measurement when stored in 22 degrees C and 4 degrees C for comparison. Concentrations of the measured analytes in samples from patients administered with a 500 mg dose of Dicynone were lower in all cases (n = 10) when compared to values in samples taken immediately before treatment. The in vitro samples showed that considerable negative interference occurred even with the low concentrations of Dicynone additions (30 and 60 mg/L), showing the strongest negative interference in creatinine values, followed by uric acid, triglycerides, and cholesterol. Using in vitro samples, we showed strong time and temperature dependence on Dicynone interference. We found and proved significant negative interference of the drug Dicynone (ethamsylate) in the clinical analysis of blood using in vivo and in vitro experiments. Furthermore, we observed a change of this effect in serum matrix over time and at different storage temperatures.

  9. Effect of Intravenous Administration of Contrast Media on Serum Creatinine Levels in Neonates.

    Science.gov (United States)

    Bedoya, Maria A; White, Ammie M; Edgar, J Christopher; Pradhan, Madhura; Raab, Elisabeth L; Meyer, James S

    2017-08-01

    Purpose To assess the effect of intravenous contrast media on renal function in neonates. Materials and Methods Institutional review board approval was obtained with waiver of consent. Electronic health records from January 2011 to April 2013 were reviewed retrospectively. Measures of renal function were obtained in inpatient neonates who underwent magnetic resonance (MR) imaging or computed tomography (CT) and for whom serum creatinine (Cr) levels were obtained within 72 hours before imaging and at least one time after imaging (>1 day after administration of contrast material). A total of 140 neonates who received contrast material (59 who underwent CT with iohexol or iodixanol and 81 who underwent MR imaging with gadopentetate dimeglumine) were identified. These neonates were frequency matched according to sex, gestational and postnatal age, and preimaging serum Cr levels with neonates who underwent unenhanced MR imaging or CT. Cr levels and glomerular filtration rates (GFRs) were grouped according to when they were obtained (before imaging, 1-2 days after imaging, 3-5 days after imaging, 6-9 days after imaging, 10-45 days after imaging, and more than 45 days after imaging). Serum Cr levels and GFRs for each time period were compared between groups by using hierarchic regressions or χ 2 or Fisher exact tests and with repeated-measures analysis of variance to compare groups on the rate of change in serum Cr levels and GFRs from before to after imaging. Results Cr levels decreased and GFRs increased in both groups from before to after imaging (CT group, P ≤ .01; MR imaging group, P ≤ .01). The neonates who underwent contrast material-enhanced imaging and the neonates who underwent unenhanced imaging showed similar serum Cr levels at all examined time periods. Groups also did not differ in the proportion of neonates with serum Cr levels higher than the reference range (>0.4 mg/dL) at any time point (iodine- [P > .12] or gadolinium-based [P > .13] contrast

  10. Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Don Kyoung; Choi, See Min; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun [Sungkyunkwan University School of Medicine, Department of Urology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Bong Hee [The Catholic University of Korea College of Medicine, Department of Urology, Incheon St. Mary' s Hospital, Seoul (Korea, Republic of)

    2015-11-15

    We aimed to evaluate the performance of various GFR estimates compared with direct measurement of GFR (dGFR). We also sought to create a new formula for volume-based GFR (new-vGFR) using kidney volume determined by CT. GFR was measured using creatinine-based methods (MDRD, the Cockcroft-Gault equation, CKD-EPI formula, and the Mayo clinic formula) and the Herts method, which is volume-based (vGFR). We compared performance between GFR estimates and created a new vGFR model by multiple linear regression analysis. Among the creatinine-based GFR estimates, the MDRD and C-G equations were similarly associated with dGFR (correlation and concordance coefficients of 0.359 and 0.369 and 0.354 and 0.318, respectively). We developed the following new kidney volume-based GFR formula: 217.48-0.39XA + 0.25XW-0.46XH-54.01XsCr + 0.02XV-19.89 (if female) (A = age, W = weight, H = height, sCr = serum creatinine level, V = total kidney volume). The MDRD and CKD-EPI had relatively better accuracy than the other creatinine-based methods (30.7 % vs. 32.3 % within 10 % and 78.0 % vs. 73.0 % within 30 %, respectively). However, the new-vGFR formula had the most accurate results among all of the analyzed methods (37.4 % within 10 % and 84.6 % within 30 %). The new-vGFR can replace dGFR or creatinine-based GFR for assessing kidney function in donors and healthy individuals. (orig.)

  11. Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs

    International Nuclear Information System (INIS)

    Choi, Don Kyoung; Choi, See Min; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Hyun Moo; Choi, Han-Yong; Jeon, Hwang Gyun; Park, Bong Hee

    2015-01-01

    We aimed to evaluate the performance of various GFR estimates compared with direct measurement of GFR (dGFR). We also sought to create a new formula for volume-based GFR (new-vGFR) using kidney volume determined by CT. GFR was measured using creatinine-based methods (MDRD, the Cockcroft-Gault equation, CKD-EPI formula, and the Mayo clinic formula) and the Herts method, which is volume-based (vGFR). We compared performance between GFR estimates and created a new vGFR model by multiple linear regression analysis. Among the creatinine-based GFR estimates, the MDRD and C-G equations were similarly associated with dGFR (correlation and concordance coefficients of 0.359 and 0.369 and 0.354 and 0.318, respectively). We developed the following new kidney volume-based GFR formula: 217.48-0.39XA + 0.25XW-0.46XH-54.01XsCr + 0.02XV-19.89 (if female) (A = age, W = weight, H = height, sCr = serum creatinine level, V = total kidney volume). The MDRD and CKD-EPI had relatively better accuracy than the other creatinine-based methods (30.7 % vs. 32.3 % within 10 % and 78.0 % vs. 73.0 % within 30 %, respectively). However, the new-vGFR formula had the most accurate results among all of the analyzed methods (37.4 % within 10 % and 84.6 % within 30 %). The new-vGFR can replace dGFR or creatinine-based GFR for assessing kidney function in donors and healthy individuals. (orig.)

  12. THE PATTERN OF LONGITUDINAL CHANGE IN SERUM CREATININE AND NINETY-DAY MORTALITY AFTER MAJOR SURGERY

    Science.gov (United States)

    Hobson, Charles E; Pardalos, Panos

    2016-01-01

    Objective Calculate mortality risk that accounts for both severity and recovery of postoperative kidney dysfunction using the pattern of longitudinal change in creatinine. Summary Background Data Although the importance of renal recovery after acute kidney injury (AKI) is increasingly recognized, the complex association that accounts for longitudinal creatinine changes and mortality is not fully described. Methods We used routinely collected clinical information for 46,299 adult patients undergoing major surgery to develop a multivariable probabilistic model optimized for non-linearity of serum creatinine time series that calculates the risk function for ninety-day mortality. We performed a 70/30 cross validation analysis to assess the accuracy of the model. Results All creatinine time series exhibited nonlinear risk function in relation to ninety-day mortality and their addition to other clinical factors improved the model discrimination. For any given severity of AKI, patients with complete renal recovery, as manifested by the return of the discharge creatinine to the baseline value, experienced a significant decrease in the odds of dying within ninety days of admission compared to patients with partial recovery. Yet, for any severity of AKI even complete renal recovery did not entirely mitigate the increased odds of dying as patients with mild AKI and complete renal recovery still had significantly increased odds for dying compared to patients without AKI (odds ratio 1,48 (95% confidence interval 1.30-1.68). Conclusions We demonstrate the nonlinear relationship between both severity and recovery of renal dysfunction and ninety-day mortality after major surgery. We have developed an easily applicable computer algorithm that calculates this complex relationship. PMID:26181482

  13. A validated LC-MS/MS method for the quantitative measurement of creatinine as an endogenous biomarker in human plasma.

    Science.gov (United States)

    Zhao, Yue; Liu, Guowen; Angeles, Aida; Christopher, Lisa J; Wang, Zhaoqing; Arnold, Mark E; Shen, Jim X

    2016-10-01

    Creatinine is an endogenous compound generated from creatine by normal muscular metabolism. It is an important indicator of renal function and the serum level is routinely monitored in clinical labs. Results & methodology: Surrogate analyte (d3-creatinine) was used for calibration standard and quality control preparation and the relative instrument response ratio between creatinine and d3-creatinine was used to calculate the endogenous creatinine concentrations. A fit-for-purpose strategy of using a surrogate analyte and authentic matrix was adopted for this validation. The assay was the first human plasma assay using such strategy and was successfully applied to a clinical study to confirm a transient elevation of creatinine observed using an existing clinical assay.

  14. C-reactive protein and serum creatinine, but not haemoglobin A1c, are independent predictors of coronary heart disease risk in non-diabetic Chinese.

    Science.gov (United States)

    Salim, Agus; Tai, E Shyong; Tan, Vincent Y; Welsh, Alan H; Liew, Reginald; Naidoo, Nasheen; Wu, Yi; Yuan, Jian-Min; Koh, Woon P; van Dam, Rob M

    2016-08-01

    In western populations, high-sensitivity C-reactive protein (hsCRP), and to a lesser degree serum creatinine and haemoglobin A1c, predict risk of coronary heart disease (CHD). However, data on Asian populations that are increasingly affected by CHD are sparse and it is not clear whether these biomarkers can be used to improve CHD risk classification. We conducted a nested case-control study within the Singapore Chinese Health Study cohort, with incident 'hard' CHD (myocardial infarction or CHD death) as an outcome. We used data from 965 men (298 cases, 667 controls) and 528 women (143 cases, 385 controls) to examine the utility of hsCRP, serum creatinine and haemoglobin A1c in improving the prediction of CHD risk over and above traditional risk factors for CHD included in the ATP III model. For each sex, the performance of models with only traditional risk factors used in the ATP III model was compared with models with the biomarkers added using weighted Cox proportional hazards analysis. The impact of adding these biomarkers was assessed using the net reclassification improvement index. For men, loge hsCRP (hazard ratio 1.25, 95% confidence interval: 1.05; 1.49) and loge serum creatinine (hazard ratio 4.82, 95% confidence interval: 2.10; 11.04) showed statistically significantly associations with CHD risk when added to the ATP III model. We did not observe a significant association between loge haemoglobin A1c and CHD risk (hazard ratio 1.83, 95% confidence interval: 0.21; 16.06). Adding hsCRP and serum creatinine to the ATP III model improved risk classification in men with a net gain of 6.3% of cases (p-value = 0.001) being reclassified to a higher risk category, while it did not significantly reduce the accuracy of classification for non-cases. For women, squared hsCRP was borderline significantly (hazard ratio 1.01, 95% confidence interval: 1.00; 1.03) and squared serum creatinine was significantly (hazard ratio 1.81, 95% confidence interval: 1.49; 2

  15. A meta-analysis on diagnostic value of serum cystatin C and creatinine for the evaluation of glomerular filtration function in renal transplant patients.

    Science.gov (United States)

    Pan, Pan; Binjie, Hu; Min, Li; Lipei, Fan; Yanli, Ni; Junwen, Zhou; Xianghua, Shi

    2014-12-01

    This meta-analysis aimed to perform a systematic review on comparing the diagnostic value of serum cystatin C and creatinine for glomerular filtration rate in renal transplant patients. The data was extracted into 2×2 table after the articles were assessed by the tool of QUADAS and heterogeneity analysis. The SROC curve and meta-analysis were performed by MetaDisc1.4. Meta-analysis showed that the serum cystatin C had no heterogeneity (P=0.418, I2=2.2%, DOR=25.03), while creatinine heterogeneity was high (P=0.109, I2=37.5%, DOR=9.11). The values of SEN, SPE and SAUC were calculated as 0.86, 0.70 and 0.9015 for cystatin C, and 0.78, 0.73 and 0.8285 for creatinine individually. This study utilized GFR detection and subgroups analysis by cutoff. The PLR was 6.13 and the NLR was 0.12 for cystatin C, compared to SCr (3.72, 0.32). There was homogeneity among these studies using PENIA testing for cystatin C (χ2=2.61, P=0.4560, I2=0.0%. There were significant correlations among cystatin C , creatinine and glomerular filtration rate (GFR). Cystatin C had more sensitivity but less specificity than creatinine for evaluation of GFR. Cystatin C had strong ability in diagnosing renal function after renal transplant and ruling out diagnostic efficacy.

  16. Inhibitory Effect of Crizotinib on Creatinine Uptake by Renal Secretory Transporter OCT2.

    Science.gov (United States)

    Arakawa, Hiroshi; Omote, Saki; Tamai, Ikumi

    2017-09-01

    Crizotinib, a tyrosine kinase inhibitor, exhibits some cases of an increase in serum creatinine levels. Creatinine is excreted by not only glomerular filtration but also active secretion by organic cation transporters such as organic cation transporter 2 (OCT2). In the present study, we evaluated in vitro inhibitory effect of crizotinib on OCT2 by directly measuring creatinine uptake by OCT2. Coincubation of crizotinib reduced uptake of [ 14 C]creatinine by cultured HEK293 cells expressing OCT2 (HEK293/OCT2) in a concentration-dependent manner with IC 50 values of 1.58 ± 0.24 μM. Preincubation or both preincubation and coincubation (preincubation/coincubation) with crizotinib showed stronger inhibitory effect on [ 14 C]creatinine uptake compared with that in coincubation alone with IC 50 values of 0.499 ± 0.076 and 0.347 ± 0.040 μM, respectively. These IC 50 values of crizotinib on [ 3 H]N-methyl-4-phenylpyridinium acetate uptake by OCT2 were 10-20 times higher than those of [ 14 C]creatinine uptake. Furthermore, preincubation of crizotinib inhibited creatinine uptake by OCT2 in an apparently competitive manner. In conclusion, crizotinib at a clinically relevant concentration has the potential to inhibit creatinine transport by OCT2, suggesting an increase of serum creatinine levels in clinical use. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Estimating the concentration of urea and creatinine in the human serum of normal and dialysis patients through Raman spectroscopy.

    Science.gov (United States)

    de Almeida, Maurício Liberal; Saatkamp, Cassiano Junior; Fernandes, Adriana Barrinha; Pinheiro, Antonio Luiz Barbosa; Silveira, Landulfo

    2016-09-01

    Urea and creatinine are commonly used as biomarkers of renal function. Abnormal concentrations of these biomarkers are indicative of pathological processes such as renal failure. This study aimed to develop a model based on Raman spectroscopy to estimate the concentration values of urea and creatinine in human serum. Blood sera from 55 clinically normal subjects and 47 patients with chronic kidney disease undergoing dialysis were collected, and concentrations of urea and creatinine were determined by spectrophotometric methods. A Raman spectrum was obtained with a high-resolution dispersive Raman spectrometer (830 nm). A spectral model was developed based on partial least squares (PLS), where the concentrations of urea and creatinine were correlated with the Raman features. Principal components analysis (PCA) was used to discriminate dialysis patients from normal subjects. The PLS model showed r = 0.97 and r = 0.93 for urea and creatinine, respectively. The root mean square errors of cross-validation (RMSECV) for the model were 17.6 and 1.94 mg/dL, respectively. PCA showed high discrimination between dialysis and normality (95 % accuracy). The Raman technique was able to determine the concentrations with low error and to discriminate dialysis from normal subjects, consistent with a rapid and low-cost test.

  18. Evaluation of bilirubin interference and accuracy of six creatinine assays compared with isotope dilution-liquid chromatography mass spectrometry.

    Science.gov (United States)

    Nah, Hyunjin; Lee, Sang-Guk; Lee, Kyeong-Seob; Won, Jae-Hee; Kim, Hyun Ok; Kim, Jeong-Ho

    2016-02-01

    The aim of this study was to estimate bilirubin interference and accuracy of six routine methods for measuring creatinine compared with isotope dilution-liquid chromatography mass spectrometry (ID-LC/MS). A total of 40 clinical serum samples from 31 patients with serum total bilirubin concentration >68.4μmol/L were collected. Serum creatinine was measured using two enzymatic reagents and four Jaffe reagents as well as ID-LC/MS. Correlations between bilirubin concentration and percent difference in creatinine compared with ID-LC/MS were analyzed to investigate bilirubin interference. Bias estimations between the six reagents and ID-LC/MS were performed. Recovery tests using National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 967a were also performed. Both the enzymatic methods showed no bilirubin interference. However, three of the four Jaffe methods demonstrated significant bilirubin concentration-dependent interference in samples with creatinine levels creatinine levels ranging from 53.0 to 97.2μmol/L. Comparison of these methods with ID-LC/MS using patients' samples with elevated bilirubin revealed that the tested methods failed to achieve the bias goal at especially low levels of creatinine. In addition, recovery test using NIST SRM 967a showed that bias in one Jaffe method and two enzymatic methods did not achieve the bias goal at either low or high level of creatinine, indicating they had calibration bias. One enzymatic method failed to achieve all the bias goals in both comparison experiment and recovery test. It is important to understand that both bilirubin interference and calibration traceability to ID-LC/MS should be considered to improve the accuracy of creatinine measurement. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Serum cystatin C levels in preterm newborns in our setting: Correlation with serum creatinine and preterm pathologies.

    Science.gov (United States)

    Bardallo Cruzado, Leonor; Pérez González, Elena; Martínez Martos, Zoraima; Bermudo Guitarte, Carmen; Granero Asencio, Mercedes; Luna Lagares, Salud; Marín Patón, Mariano; Polo Padilla, Juan

    2015-01-01

    Cystatin C (CysC) is a renal function marker that is not as influenced as creatinine (Cr) by endogenous or exogenous agents, so it is therefore proposed as a marker in preterm infants. To determine serum CysC values in preterm infants during the first week of life, compared to Cr. To analyze alterations caused by prematurity diseases. The design involved a longitudinal, observational study of prospective cohorts. Groups were based on gestational age (GA): Group A (24-27 weeks), Group B (28-33 weeks), Group C (34-36 weeks). Blood samples were collected at birth, within 48-72hours and after 7 days of life. SPSS v.20 software was used. The statistical methods applied included chi-squared test and ANOVA. A total of 109 preterm infants were included in the study. CysC levels were: 1.54mg/L (±0.28) at birth; 1.38mg/L (±0.36) within 48-72hours of life; 1.50mg/L (±0.31) after 7 days (p<0.05). Cr levels were: 0.64mg/dL (±0.17) at birth; 0.64mg/dL (±0.28) within 48-72hours; 0.56mg/dL (±0.19) after 7 days (P<.05). CysC values were lower in hypotensive patients and those with a respiratory disease (P<.05), and no alterations associated with other diseases were observed. There were no differences in Cr levels associated with any disease. Creatinine levels were higher in patients ≤1.500g (P<.05). Serum CysC decreased within 48-72hours of life, and this decline showed significance (P<.05). The levels increased after 7 days in all 3 GA groups, and there was no difference in CysC levels among the groups. More studies in preterm infants with hypotension and respiratory disease are required. CysC is a better glomerular filtration (GF) marker in ≤1.500g preterm infants. Copyright © 2015 The Authors. Published by Elsevier España, S.L.U. All rights reserved.

  20. Therapeutic effect of continuous exercise training program on serum creatinine concentration in men with hypertension: a randomized controlled trial.

    Science.gov (United States)

    Sikiru, L; Okoye, G C

    2014-09-01

    Creatinine (Cr) has been implicated as an independent predictor of hypertension and exercise has been reported as adjunct therapy for hypertension. The purpose of the present study was to investigate the effect of continuous training programme on blood pressure and serum creatinine concentration in black African subjects with hypertension. Three hundred and fifty seven male patients with mild to moderate (systolic blood pressure [SBP] between 140-180 & diastolic blood pressure [DBP] between 90-109 mmHg) essential hypertension were age matched and randomly grouped into continuous & control groups. The continuous group involved in an 8 weeks continuous training (60-79% HR reserve) of between 45 minutes to 60 minutes, 3 times per week, while the control group remain sedentary. SBP, DBP, VO2max, serum Cr, body mass index (BMI), waist hip ratio (WHR) and percent (%) body fat. Analysis of covariance (ANCOVA) and Pearson correlation tests were used in data analysis. Findings of the study revealed significant decreased effects of continuous training programme on SBP, DBP, Cr, BMI, WHR, % body fat and significant increase in VO2max at pexercise training as a multi-therapy in the down regulation of blood pressure, serum Cr, body size and body fat in hypertension.

  1. Cystatin C versus Creatinine in Determining Risk Based on Kidney Function

    NARCIS (Netherlands)

    Shlipak, Michael G.; Matsushita, Kunihiro; Arnlov, Johan; Inker, Lesley A.; Katz, Ronit; Polkinghorne, Kevan R.; Rothenbacher, Dietrich; Sarnak, Mark J.; Astor, Brad C.; Coresh, Josef; Levey, Andrew S.; Gansevoort, Ron T.

    2013-01-01

    BACKGROUND Adding the measurement of cystatin C to that of serum creatinine to determine the estimated glomerular filtration rate (eGFR) improves accuracy, but the effect on detection, staging, and risk classification of chronic kidney disease across diverse populations has not been determined.

  2. Utilization of small changes in serum creatinine with clinical risk factors to assess the risk of AKI in critically lll adults.

    Science.gov (United States)

    Cruz, Dinna N; Ferrer-Nadal, Asunción; Piccinni, Pasquale; Goldstein, Stuart L; Chawla, Lakhmir S; Alessandri, Elisa; Belluomo Anello, Clara; Bohannon, Will; Bove, Tiziana; Brienza, Nicola; Carlini, Mauro; Forfori, Francesco; Garzotto, Francesco; Gramaticopolo, Silvia; Iannuzzi, Michele; Montini, Luca; Pelaia, Paolo; Ronco, Claudio

    2014-04-01

    Disease biomarkers require appropriate clinical context to be used effectively. Combining clinical risk factors, in addition to small changes in serum creatinine, has been proposed to improve the assessment of AKI. This notion was developed in order to identify the risk of AKI early in a patient's clinical course. We set out to assess the performance of this combination approach. A secondary analysis of data from a prospective multicenter intensive care unit cohort study (September 2009 to April 2010) was performed. Patients at high risk using this combination approach were defined as an early increase in serum creatinine of 0.1-0.4 mg/dl, depending on number of clinical factors predisposing to AKI. AKI was defined and staged using the Acute Kidney Injury Network criteria. The primary outcome was evolution to severe AKI (Acute Kidney Injury Network stages 2 and 3) within 7 days in the intensive care unit. Of 506 patients, 214 (42.2%) patients had early creatinine elevation and were deemed at high risk for AKI. This group was more likely to subsequently develop the primary endpoint (16.4% versus 1.0% [not at high risk], Pcreatinine, and hazard tier for AKI, early creatinine elevation remained an independent predictor for severe AKI (adjusted relative risk, 12.86; 95% confidence interval, 3.52 to 46.97). Addition of early creatinine elevation to the best clinical model improved prediction of the primary outcome (area under the receiver operating characteristic curve increased from 0.75 to 0.83, Phigh AKI risk, based on the combination of clinical factors and early creatinine elevation, are significantly more likely to develop severe AKI. As initially hypothesized, the high-risk combination group methodology can be used to identify patients at low risk for severe AKI in whom AKI biomarker testing may be expected to have low yield. The high risk combination group methodology could potentially allow clinicians to optimize biomarker use.

  3. Urine creatinine in treatment-naïve HIV subjects in eastern Nigeria.

    Science.gov (United States)

    Anyabolu, Ernest Ndukaife

    2016-01-01

    Human immunodeficiency virus (HIV) infection is a global healthcare problem. Some diseases and physiological states may be altered in HIV-infected individuals. Our objective was to evaluate urine creatinine and factors that influence urine creatinine in treatment-naïve HIV subjects in Nigeria. This was a cross-sectional study involving treatment-naïve HIV subjects in a tertiary hospital in Nigeria. Creatinine in spot and 24-hour urine samples and other relevant investigations were performed. Low urine creatinine or dilute urine was defined as 24-hour urine creatinine (24HUCr) creatinine as 24HUCr 300-3000mg and high urine creatinine or concentrated urine as 24HUCr>3000mg.Theassociation of low urine creatinine and high urine creatinine with potential risk factors was determined. The mean spot urine creatinine (SUCr) of the treatment-naïve HIV subjects was 137.21± 98.47(mg/dl), minimum value 13.3mg/dl, maximum value 533.3mg/dl and range of values 520.0mg/dl. The mean 24HUCr was 1507±781mg, minimum value 206mg, maximum value 4849mg and range of values 4643mg. Twenty four-hour urine creatinine3000mg in 24(6.4%) subjects. There was significant association between 24HUCr and serum low density lipoprotein cholesterol (LDL),serum high density lipoprotein cholesterol (HDL). There was high correlation between 24HUCr>3000mg and 24-hour urine osmolality (24HUOsm) (r=0.95), body mass index (BMI) (r=0.74), CD4 cells count (r=-0.71), serum HDL (r=-0.73). The prevalence of dilute urine and concentrated urine was low. Twenty-four hour urine osmolality. BMI, CD4 cells count and HDL were strong correlates of high urine creatinine. Lipid abnormalities were common in treatment-naïve HIV subjects with high urine creatinine. There is need for clinicians to routinely conduct urine creatinine and further search for abnormalities of serum lipids, weight changes, depressed immunity and anemia in HIV subjects with dilute or concentrated urine in the early stages of the infection.

  4. Serum Creatinine in Patients with Advanced Liver Disease Is of Limited Value for Identification of Moderate Renal Dysfunction: Are the Equations for Estimating Renal Function Better?

    Directory of Open Access Journals (Sweden)

    Jillian MacAulay

    2006-01-01

    Full Text Available BACKGROUND: The Cockcroft-Gault formula (CGF is used to estimate the glomerular filtration rate (GFR based on serum creatinine (Cr levels, age and sex. A new formula developed by the Modification of Diet in Renal Disease (MDRD Study Group, based on the patient’s Cr levels, age, sex, race and serum urea nitrogen and serum albumin levels, has shown to be more accurate. However, the best formula to identify patients with advanced liver disease (ALD and moderate renal dysfunction (GFR 60 mL/min/1.73 m2 or less is not known. The aim of the present study was to compare calculations of GFR, using published formulas (excluding those requiring urine collections with standard radionuclide measurement of GFR in patients with ALD.

  5. Creatinine measurement on dry blood spot sample for chronic kidney disease screening.

    Science.gov (United States)

    Silva, Alan Castro Azevedo E; Gómez, Juan Fidel Bencomo; Lugon, Jocemir Ronaldo; Graciano, Miguel Luis

    2016-03-01

    Chronic kidney disease (CKD) screening is advisable due to its high morbidity and mortality and is usually performed by sampling blood and urine. Here we present an innovative and simpler method, by measuring creatinine on a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. The creatinine values obtained using both tests and the demographic data of each participant allowed us to determinate the eGFR. The adopted cutoff for CKD was an eGFR creatinine values differences (+ 0.68mg/dl to -0.55mg/dl) inside the ± 1.96 SD, without systematic differences. Measurement of creatinine on dry blood sample is an easily feasible non-invasive diagnostic test with good accuracy that may be useful to screen chronic kidney disease.

  6. Creatinine measurements often yielded false estimates of progression in chronic renal failure

    International Nuclear Information System (INIS)

    Walser, M.; Drew, H.H.; LaFrance, N.D.

    1988-01-01

    In 9 of 22 observation periods (lasting an average of 15 months) in 17 patients with moderate to severe chronic renal failure (GFR 4 to 23 ml/min), rates of progression as estimated from the linear regression on time of 24-hour creatinine clearance (b1) differed significantly from rates of progression as estimated from the regression on time of urinary clearance of 99mTc-DTPA (b2), during all or part of the period of observation. b1 exceeded b2 in four cases and was less than b2 in the other five. Thus there were gradual changes in the fractional tubular secretion of creatinine in individual patients, in both directions. Owing to these changes, measurements of creatinine clearance gave erroneous impressions of the rate or existence of progression during all or a portion of the period of observation in nearly half of these patients. In the 22 studies as a group, using the entire periods of observation, b1 indicated significantly more rapid progression (by 0.18 +/- 0.06 ml/min/month, P less than 0.01) than did b2, and had a significantly greater variance. Measurements of progression based on the rate of change of reciprocal plasma creatinine (multiplied by an average rate of urinary creatinine excretion in each study) were equally misleading, even though less variable. We conclude that sequential creatinine measurements are often misleading as measures of progression and should, when feasible, be replaced by urinary clearance of isotopes in following patients with chronic renal failure

  7. Validation of the salivary urea and creatinine tests as screening methods of chronic kidney disease in Vietnamese patients.

    Science.gov (United States)

    Pham, Thuy Anh Vu

    2017-11-01

    The aims of this case control study were to correlate the serum and salivary urea as well as creatinine levels; and to evaluate salivary urea and creatinine as noninvasive alternatives to serum for creatinine estimation in chronic kidney disease (CKD) patients. Blood and saliva samples were collected from 112 CKD patients and 108 subjects without CKD for quantitative analysis of urea and creatinine. Spearman's correlation coefficients between salivary and serum urea as well as creatinine were obtained. Receiver operating characteristic analysis was done to assess the diagnostic tests of salivary urea and creatinine. Cut-off values were determined based on the best trade-off between the sensitivity and specificity for both salivary urea and creatinine. Salivary urea and creatinine concentrations were significantly higher in CKD patients than those in control subjects; and increased by the stages of the severity of the disease. The positive correlation was significantly found between salivary and serum creatinine (r  =  0.90) and between salivary and serum urea (r  =  0.73). Area under the curve for salivary urea was 0.76 and a cut-off value of 14.25 mmol/L gave a sensitivity of 82.9% and specificity of 57.8%. Area under the curve for salivary creatinine was 0.92 and a cut-off value of 0.24 mg/dL gave a sensitivity of 86.5% and specificity of 87.2%. Both salivary urea and creatinine have a high capacity for serum creatinine estimation. Salivary urea and creatinine tests can be used as low-cost, easily accessible and noninvasive tools for screening, diagnosing, monitoring treatment outcomes and ascertaining prognosis of chronic kidney disease.

  8. Falsely Elevated Plasma Creatinine Due to an Immunoglobulin M Paraprotein.

    Science.gov (United States)

    McGill, Mitchell R; Vijayan, Anitha; Trulock, Elbert P; Witt, Chad A; Kohler, Giselle D; Scott, Mitchell G

    2016-11-01

    The most common method for measuring plasma creatinine is based on its reaction with picric acid. However, enzymatic methods are becoming more popular due to improved specificity. We present a case of falsely elevated plasma creatinine values obtained by an enzymatic method that turned out to be due to a monoclonal immunoglobulin M (IgM) paraprotein. A 63-year-old woman evaluated for lung transplantation had falsely increased plasma creatinine levels (1.54-1.71mg/dL; corresponding to estimated glomerular filtration rates of 32-36 mL/min/1.73m 2 ) as measured by the Roche Creatinine plus enzymatic assay when compared with the picric acid-based procedure and several other enzymatic methods, which gave plasma creatinine values of 0.7 to 0.8mg/dL. Serum protein electrophoresis revealed an IgM κ light chain paraprotein. Removal of high-molecular-weight (>30kDa) proteins by ultrafiltration reduced the patient's plasma creatinine level by the Roche enzymatic method to 0.7mg/dL. Addition of the patient's immunoglobulin fraction to plasma from other patients with normal plasma creatinine levels resulted in values that were increased by 0.58 to 0.62mg/dL. Furthermore, removal of non-IgM immunoglobulins with protein G-coupled beads did not eliminate the interference from the patient's plasma. Taken together, these studies demonstrate that falsely elevated plasma creatinine values by the Roche enzymatic method can be due to an IgM paraprotein. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  9. Renal function in the fetus and neonate - the creatinine enigma.

    Science.gov (United States)

    Kastl, Justin T

    2017-04-01

    The use of serum creatinine levels to estimate glomerular function in infants is admittedly fraught with inherent inaccuracies which are both physiological and methodological in nature. This characteristic can understandably reduce the neonatal clinician's confidence in the ability of serum creatinine levels to provide useful information relevant to their patients' medical care. The aim of this review is to provide further insight into the peculiarities of serum creatinine trends in both premature and term infants with special focus on the maturational and developmental changes occurring in the kidney during this crucial time-period. Though newer markers of glomerular function are gaining increasing traction in the clinical realm, the most prominent of which is currently cystatin C, creatinine nonetheless remains an important player in the scientific evolution of glomerular filtration rate (GFR) estimation. Not only do its limitations provide a level of distinction for newer markers of GFR, but its advantages persist in refining the precision of newer GFR formulae which incorporate multiple patient characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Relevance of Changes in Serum Creatinine During a Heart Failure Trial of Decongestive Strategies: Insights From the DOSE Trial.

    Science.gov (United States)

    Brisco, Meredith A; Zile, Michael R; Hanberg, Jennifer S; Wilson, F Perry; Parikh, Chirag R; Coca, Steven G; Tang, W H Wilson; Testani, Jeffrey M

    2016-10-01

    Worsening renal function (WRF) is a common endpoint in decompensated heart failure clinical trials because of associations between WRF and adverse outcomes. However, WRF has not universally been identified as a poor prognostic sign, challenging the validity of WRF as a surrogate endpoint. Our aim was to describe the associations between changes in creatinine and adverse outcomes in a clinical trial of decongestive therapies. We investigated the association between changes in creatinine and the composite endpoint of death, rehospitalization or emergency room visit within 60 days in 301 patients in the Diuretic Optimization Strategies Evaluation (DOSE) trial. WRF was defined as an increase in creatinine >0.3 mg/dL and improvement in renal function (IRF) as a decrease >0.3 mg/dL. When examining linear changes in creatinine from baseline to 72 hours (the coprimary endpoint of DOSE), increasing creatinine was associated with lower risk for the composite outcome (HR = 0.81 per 0.3 mg/dL increase, 95% CI 0.67-0.98, P = .026). Compared with patients with stable renal function (n = 219), WRF (n = 54) was not associated with the composite endpoint (HR = 1.17, 95% CI = 0.77-1.78, P = .47). However, compared with stable renal function, there was a strong relationship between IRF (n = 28) and the composite endpoint (HR = 2.52, 95% CI = 1.57-4.03, P creatinine, was paradoxically associated with improved outcomes. This was driven by absence of risk attributable to WRF and a strong risk associated with IRF. These results argue against using changes in serum creatinine as a surrogate endpoint in trials of decongestive strategies. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Labeling of creatinine with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Yurt Lambrecht, F. [Ege Univ., Bornova, Izmir (Turkey). Dept. of Nuclear Applications, Inst. of Nuclear Sciences; Durkan, K. [Dokuz Eylul Univ., Buca, Izmir (Turkey). Chemistry Technicianship Program, Izmir Vocational School; Soylu, A. [Dokuz Eylul Univ., Narlidere, Izmir (Turkey). Dept. of Pediatrics, Medical Faculty

    2004-07-01

    Creatinine is a clinically important index of renal glomerular filtration rate. Urine creatinine levels can be used as a screening test to evaluate kidney function or can be part of the creatinine clearance test. In case of kidney dysfunction or muscle disorders the creatinine concentration in serum/plasma may rise to a higher value than in healthy body. Technetium- 99m has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. {sup 99m}Tc is utilized to label molecules and cells, used as radiopharmaceuticals, and also to label biological species. It presents many desirable characteristics. SnCl{sub 2} method is frequently used as a reducing agent in the {sup 99m}Tc- labeling process. Creatinine metabolism might be investigated by using labeled {sup 99m}Tc- creatinine in healthy or uremic rats. (orig.)

  12. Re-recognition of Age-dependent Reference Range for the Serum Creatinine Level in Teenagers - A Case of Slowly Progressive Tubulointerstitial Nephritis which Occurred in an Adolescent.

    Science.gov (United States)

    Ono, Hiroyuki; Nagai, Kojiro; Shibata, Eriko; Matsuura, Motokazu; Kishi, Seiji; Inagaki, Taizo; Minato, Masanori; Yoshimoto, Sakiya; Ueda, Sayo; Obata, Fumiaki; Nishimura, Kenji; Tamaki, Masanori; Kishi, Fumi; Murakami, Taichi; Abe, Hideharu; Kinoshita, Yukiko; Urushihara, Maki; Kagami, Shoji; Doi, Toshio

    2017-08-15

    For the first time, a 15-year-old boy was found to have a slight degree of proteinuria and microscopic hematuria during annual school urinalysis screening. His kidney function had already severely deteriorated. A kidney biopsy revealed tubulointerstitial nephritis (TIN) with diffuse inflammatory cell infiltration. His medical records showed his serum creatinine level to be 0.98 mg/dL two years ago, which was abnormally high considering his age. Although the etiology of slowly progressive TIN was unclear, glucocorticoid and immunosuppressant therapy improved his kidney function. This case report suggests that all doctors should recognize the reference range for the serum creatinine level in teenagers.

  13. Comparing cystatin C and creatinine in the diagnosis of pediatric acute renal allograft dysfunction

    NARCIS (Netherlands)

    Slort, Pauline R.; Ozden, Nergiz; Pape, Lars; Offner, Gisela; Tromp, Wilma F.; Wilhelm, Abraham J.; Bokenkamp, Arend

    2012-01-01

    Allograft function following renal transplantation is commonly monitored using serum creatinine. Multiple cross-sectional studies have shown that serum cystatin C is superior to creatinine for detection of mild to moderate chronic kidney dysfunction. Recent data in adults indicate that cystatin C

  14. The description of a method for accurately estimating creatinine clearance in acute kidney injury.

    Science.gov (United States)

    Mellas, John

    2016-05-01

    Acute kidney injury (AKI) is a common and serious condition encountered in hospitalized patients. The severity of kidney injury is defined by the RIFLE, AKIN, and KDIGO criteria which attempt to establish the degree of renal impairment. The KDIGO guidelines state that the creatinine clearance should be measured whenever possible in AKI and that the serum creatinine concentration and creatinine clearance remain the best clinical indicators of renal function. Neither the RIFLE, AKIN, nor KDIGO criteria estimate actual creatinine clearance. Furthermore there are no accepted methods for accurately estimating creatinine clearance (K) in AKI. The present study describes a unique method for estimating K in AKI using urine creatinine excretion over an established time interval (E), an estimate of creatinine production over the same time interval (P), and the estimated static glomerular filtration rate (sGFR), at time zero, utilizing the CKD-EPI formula. Using these variables estimated creatinine clearance (Ke)=E/P * sGFR. The method was tested for validity using simulated patients where actual creatinine clearance (Ka) was compared to Ke in several patients, both male and female, and of various ages, body weights, and degrees of renal impairment. These measurements were made at several serum creatinine concentrations in an attempt to determine the accuracy of this method in the non-steady state. In addition E/P and Ke was calculated in hospitalized patients, with AKI, and seen in nephrology consultation by the author. In these patients the accuracy of the method was determined by looking at the following metrics; E/P>1, E/P1 and 0.907 (0.841, 0.973) for 0.95 ml/min accurately predicted the ability to terminate renal replacement therapy in AKI. Include the need to measure urine volume accurately. Furthermore the precision of the method requires accurate estimates of sGFR, while a reasonable measure of P is crucial to estimating Ke. The present study provides the

  15. Clinical Usefulness of Serum Cystatin C as a Marker of Renal Function

    Directory of Open Access Journals (Sweden)

    Kwang-Sook Woo

    2014-08-01

    Full Text Available BackgroundAccurate renal function measurements are important in the diagnosis and treatment of kidney diseases. In contrast to creatinine, the production of serum cystatin C has been extensively reported to be unaffected by body muscle mass, age, gender, and nutritional status.MethodsOur study included 37 samples from diabetic chronic kidney disease (CKD patients for whom serum creatinine tests had been requested and 40 samples from a healthy populations in Dong-A University Hospital between May 2010 and June 2010. The assay precision (i.e., the coefficient of variation and the reference range of the serum cystatin C test were evaluated. We compared the estimated glomerular filtration rates (GFRs based on cystatin C with those based on creatinine. Moreover, we investigated the influences of age, gender, weight, and muscle mass on serum creatinine and serum cystatin C.ResultsThere was a positive correlation between GFR based on creatinine and that based on cystatin C (r=0.79, P<0.0001 among the diabetic CKD patients. Serum creatinine and cystatin C were significantly correlated with body weight and muscle mass, but the strengths of these correlations were greater for serum creatinine. The precision study revealed excellent results for both the high and low controls. The 95% reference interval of cystatin C in the healthy population was 0.371 to 1.236 mg/L.ConclusionBased on these results, we conclude that, despite the strong correlation between serum creatinine and cystatin C, cystatin C is less affected by weight and muscle mass and might represent a better alternative for the assessment of renal function.

  16. Quantitative analysis of elevation of serum creatinine via renal transporter inhibition by trimethoprim in healthy subjects using physiologically-based pharmacokinetic model.

    Science.gov (United States)

    Nakada, Tomohisa; Kudo, Toshiyuki; Kume, Toshiyuki; Kusuhara, Hiroyuki; Ito, Kiyomi

    2018-02-01

    Serum creatinine (SCr) levels rise during trimethoprim therapy for infectious diseases. This study aimed to investigate whether the elevation of SCr can be quantitatively explained using a physiologically-based pharmacokinetic (PBPK) model incorporating inhibition by trimethoprim on tubular secretion of creatinine via renal transporters such as organic cation transporter 2 (OCT2), OCT3, multidrug and toxin extrusion protein 1 (MATE1), and MATE2-K. Firstly, pharmacokinetic parameters in the PBPK model of trimethoprim were determined to reproduce the blood concentration profile after a single intravenous and oral administration of trimethoprim in healthy subjects. The model was verified with datasets of both cumulative urinary excretions after a single administration and the blood concentration profile after repeated oral administration. The pharmacokinetic model of creatinine consisted of the creatinine synthesis rate, distribution volume, and creatinine clearance (CL cre ), including tubular secretion via each transporter. When combining the models for trimethoprim and creatinine, the predicted increments in SCr from baseline were 29.0%, 39.5%, and 25.8% at trimethoprim dosages of 5 mg/kg (b.i.d.), 5 mg/kg (q.i.d.), and 200 mg (b.i.d.), respectively, which were comparable with the observed values. The present model analysis enabled us to quantitatively explain increments in SCr during trimethoprim treatment by its inhibition of renal transporters. Copyright © 2017 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  17. Final report on EURAMET.QM-K12: EURAMET key comparison on the determination of the mass fraction of creatinine in serum

    Science.gov (United States)

    Bell, David; Hopley, Chris; Ellison, Stephen L. R.; O'Connor, Gavin

    2013-01-01

    Creatinine is a well-known marker for the evaluation of kidney function. Its routine measurement is undertaken by many clinical laboratories and comparable results over distance and time are required for effective diagnosis. To address this need many National Measurement Institutes (or designated institutes) provide services in this area via the provision of higher order standards or reference measurements. The organic analysis working group of the consultative committee for amount of substance have conducted two previous key comparisons to assess the equivalence of institutes who provide such services. The purpose of this study was to enable institutes who missed the previous studies to demonstrate their capability for characterizing serum materials containing 1 µg/g to 100 µg/g of creatinine. The study material consisted of two lyophilized serum samples which were used in an external quality control proficiency testing scheme. No target values were available for these materials and all participants reported results within the one month timeframe given for analysis. Five institutes participated in the key study and a single institute submitted results for the parallel pilot study. All participants in the key study used isotope dilution with either gas or liquid chromatography coupled with mass spectrometry. The pilot study laboratory used a novel isotope dilution surface-enhanced Raman spectroscopy method. The comparison reference value for each material was set as the mean of all results submitted by those participating in the key study. The choice of the reference value estimator was constrained as it was deemed more appropriate to treat the data in a similar manner to CCQM-K12 if the relative degrees of equivalence were to be compared. This resulted in reference values of (54.27 ± 0.72) µg/g and (38.01 ± 0.42) µg/g for the two separate materials. The relative degrees of equivalence were calculated and these were compared with the relative degrees of

  18. Correlation of glomerular filtration rate measurement using Tc-99m DTPA with cystatin-C levels and creatinine clearance for staging of chronic kidney disease

    International Nuclear Information System (INIS)

    Elliyanti, A.; Iskandar, Azmi S.

    2007-01-01

    Full text: The presence of Chronic Kidney Disease (CKD) was established based on kidney damage presence and the level of kidney function through Glomerular filtration rate (GFR). It was also recognized that renal scintigraphy (renogram) using TC-99m DTPA (diethylenetriamine pentacetic acid) has advantages in the measurement of GFR. Recently, serum Cystatin-C is proposed as the new marker of GFR. The aim of this study is to find out the correlation of GFR, derived from renogram, with Cystatin- C levels and Creatinine Clearance (CC) in CKD. Material and Methods: A total of 30 subjects (age mean is 60.8 years, 21 males and 9 females) were enrolled in this study with diagnosis stage 2 of CKD. CKD staging was determined by Cockroft-Gault (CG) equation, taking into account the serum creatinine. Renogram was performed using a single head camera with IV administration of 5 mCi DTPA. Cystatin-C and creatinine clearance (24-hours urine samples) were include in this study. Results: The mean GFR of renogram, Cystatin-C, CC and CG are 64.96 ml/min/1.73m2 (SD 28.047), 53.37 ml/min/1.73m2 (SD 21.29), 58.09 ml/min/1.73m2 (SD 35.45), 46.00 ml/min/1.73m2 (SD 12.06) respectively. There is better correlation between renogram and Cystatin-C (r=0.585, p0.0007) compared renogram and CC (r=0.388, p=0.03) or renogram and CG (r=-0.029, p=0.87). Conclusion: Cystatin-C shows better indicator of GFR than CC and CG. Serum creatinine concentration alone should not be used to assess the level of kidney function in the staging of CKD. (author)

  19. Effect of creatinine assay calibration on glomerular filtration rate prediction by MDRD equation

    Directory of Open Access Journals (Sweden)

    Débora Spessatto

    2009-01-01

    Full Text Available Background: The evaluation of renal function should be performed with glomerular filtration rate (GFR estimation employing the Modification of Diet in Renal Disease (MDRD study equation, which includes age, gender, ethnicity and serum creatinine. However, creatinine methods require traceability with standardized methods. Objective: To analyse the impact of creatinine calibration on MDRD calculated GFR. Methods: 140 samples of plasma with creatinine values <2,0 mg/dl were analysed by Jaffé’s reaction with Creatinina Modular P (Roche ®; method A; reference and Creatinina Advia 1650 (Bayer ®; method B; non-standardized. The results with the different methods were compared and aligned with standardized method through a conversion formula. MDRD GFR was estimated. Results: Values were higher for method B (1.03 ± 0.29 vs. 0.86 ± 0.32 mg/dl, P<0.001. This difference declined when methods were aligned with the equation y=1.07x -0.249, and the aligned values were 0,9 ± 0,31 mg/dl. Non-traceable creatinine methods misclassificaed chronic kidney disease in 10% more (false positive. This disagreement disappeared after the regression alignment. Conclusion: Creatinine method calibration has a large impact over the final results of serum creatinine and GFR. The alignment of the non-standardized results through conversion formulas is a reasonable alternative to harmonize serum creatinine results while waiting for the full implementation of international  standardization programs.

  20. The development of a point of care creatinine measurement using disposable ready to use microchip capillary electrophoresis

    NARCIS (Netherlands)

    Ávila Muñoz, Mónica; Eijkel, Jan C.T.; Floris, J.; Staal, S.S.; Ríos, Ángel; van den Berg, Albert

    2011-01-01

    We report on the determination of creatinine in human serum using a point-of-care device suitable for the use by untrained operators, the Medimate Multireader®. This device is based on electrophoretic separation and conductivity detection and its prefilled microfluidic chip has a single opening for

  1. Determination of the best method to estimate glomerular filtration rate from serum creatinine in adult patients with sickle cell disease: a prospective observational cohort study

    Directory of Open Access Journals (Sweden)

    Arlet Jean-Benoît

    2012-08-01

    Full Text Available Abstract Background Sickle cell disease (SCD leads to tissue hypoxia resulting in chronic organ dysfunction including SCD associated nephropathy. The goal of our study was to determine the best equation to estimate glomerular filtration rate (GFR in SCD adult patients. Methods We conducted a prospective observational cohort study. Since 2007, all adult SCD patients in steady state, followed in two medical departments, have had their GFR measured using iohexol plasma clearance (gold standard. The Cockcroft-Gault, MDRD-v4, CKP-EPI and finally, MDRD and CKD-EPI equations without adjustment for ethnicity were tested to estimate GFR from serum creatinine. Estimated GFRs were compared to measured GFRs according to the graphical Bland and Altman method. Results Sixty-four SCD patients (16 men, median age 27.5 years [range 18.0-67.5], 41 with SS-genotype were studied. They were Sub-Saharan Africa and French West Indies natives and predominantly lean (median body mass index: 22 kg/m2 [16-33]. Hyperfiltration (defined as measured GFR >110 mL/min/1.73 m2 was detected in 53.1% of patients. Urinary albumin/creatinine ratio was higher in patients with hyperfiltration than in patients with normal GFR (4.05 mg/mmol [0.14-60] versus 0.4 mg/mmol [0.7-81], p = 0.01. The CKD-EPI equation without adjustment for ethnicity had both the lowest bias and the greatest precision. Differences between estimated GFRs using the CKP-EPI equation and measured GFRs decreased with increasing GFR values, whereas it increased with the Cockcroft-Gault and MDRD-v4 equations. Conclusions We confirm that SCD patients have a high rate of glomerular hyperfiltration, which is frequently associated with microalbuminuria or macroalbuminuria. In non-Afro-American SCD patients, the best method for estimating GFR from serum creatinine is the CKD-EPI equation without adjustment for ethnicity. This equation is particularly accurate to estimate high GFR values, including glomerular

  2. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    Science.gov (United States)

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  3. Simultaneous GC-ECNICI-MS measurement of nitrite, nitrate and creatinine in human urine and plasma in clinical settings.

    Science.gov (United States)

    Hanff, Erik; Lützow, Moritz; Kayacelebi, Arslan Arinc; Finkel, Armin; Maassen, Mirja; Yanchev, Georgi Radoslavov; Haghikia, Arash; Bavendiek, Udo; Buck, Anna; Lücke, Thomas; Maassen, Norbert; Tsikas, Dimitrios

    2017-03-15

    and U NOx R in 17 healthy young men. Compared to NaCl (n=8), NaNO 3 (n=9) supplementation increased U NOx R (1709±355 vs. 369±77, P<0.05). Creatinine excretion did not differ between the groups (6.67±1.34mM vs. 5.72±1.27mM, P=0.57). The method is also applicable to human plasma. In 78 adults patients newly diagnosed for cerebrovascular disease (CVD), there was a close correlation (r=0.9833) between the creatinine concentrations measured in plasma by GC-ECNICI-MS and those measured in serum by an enzymatic assay. Creatinine-corrected plasma nitrate and nitrite concentrations (P=0.035 and P=0.004, respectively) but not their concentrations (P=0.68 and P=0.40, respectively) differ between male (n=54) and female (n=24) CVD patients. No such differences were found between preterm newborn boys (n=25) and girls (n=22). Like in urine, circulating creatinine may be useful to correct for gender-specific differences in plasma nitrite and nitrate in adults. Chronic NaNO 3 supplementation to healthy young men does not affect renal CA-dependent nitrite excretion or creatinine synthesis and excretion. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Serum creatinine elevation after renin-angiotensin system blockade and long term cardiorenal risks: cohort study.

    Science.gov (United States)

    Schmidt, Morten; Mansfield, Kathryn E; Bhaskaran, Krishnan; Nitsch, Dorothea; Sørensen, Henrik Toft; Smeeth, Liam; Tomlinson, Laurie A

    2017-03-09

    Objective  To examine long term cardiorenal outcomes associated with increased concentrations of creatinine after the start of angiotensin converting enzyme inhibitor/angiotensin receptor blocker treatment. Design  Population based cohort study using electronic health records from the Clinical Practice Research Datalink and Hospital Episode Statistics. Setting  UK primary care, 1997-2014. Participants  Patients starting treatment with angiotensin converting enzyme inhibitors or angiotensin receptor blockers (n=122 363). Main outcome measures  Poisson regression was used to compare rates of end stage renal disease, myocardial infarction, heart failure, and death among patients with creatinine increases of 30% or more after starting treatment against those without such increases, and for each 10% increase in creatinine. Analyses were adjusted for age, sex, calendar period, socioeconomic status, lifestyle factors, chronic kidney disease, diabetes, cardiovascular comorbidities, and use of other antihypertensive drugs and non-steroidal anti-inflammatory drugs. Results  Among the 2078 (1.7%) patients with creatinine increases of 30% or more, a higher proportion were female, were elderly, had cardiorenal comorbidity, and used non-steroidal anti-inflammatory drugs, loop diuretics, or potassium sparing diuretics. Creatinine increases of 30% or more were associated with an increased adjusted incidence rate ratio for all outcomes, compared with increases of less than 30%: 3.43 (95% confidence interval 2.40 to 4.91) for end stage renal disease, 1.46 (1.16 to 1.84) for myocardial infarction, 1.37 (1.14 to 1.65) for heart failure, and 1.84 (1.65 to 2.05) for death. The detailed categorisation of increases in creatinine concentrations (creatinine increases of less than 30% were also associated with increased incidence rate ratios for all outcomes, including death (1.15 (1.09 to 1.22) for increases of 10-19% and 1.35 (1.23 to 1.49) for increases of 20-29%, using creatinine

  5. 21 CFR 862.1225 - Creatinine test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Creatinine test system. 862.1225 Section 862.1225....1225 Creatinine test system. (a) Identification. A creatinine test system is a device intended to measure creatinine levels in plasma and urine. Creatinine measurements are used in the diagnosis and...

  6. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    OpenAIRE

    Pickering, John W; Frampton, Christopher M; Walker, Robert J; Shaw, Geoffrey M; Endre, Zolt?n H

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 h...

  7. Comparative study of three methods of estimation of creatinine clearance in critically ill patients.

    Science.gov (United States)

    Blasco, V; Antonini, F; Zieleskiewicz, L; Hammad, E; Albanèse, J; Martin, C; Leone, M

    2014-05-01

    At the bedside, the reference method for creatinine clearance determination is based on the measurement of creatinine concentrations in urine and serum (mCrCl). Several models are available to calculate the creatinine clearance from the serum creatinine concentration. This observational survey aimed at testing the hypothesis that the proposed equations are unreliable to determine accurate creatinine clearance in patients admitted to intensive care unit (ICU). Creatinine clearance was determined by the use of mCrCl. Then, we compared three equations: Cockcroft-Gault (CG), Simplified Modification of Diet in Renal Disease (MDRDs), and Chronic Kidney Disease Epidemiology (CKD-EPI) in 156 consecutive patients within the first 24hours after ICU admission. We tested the hypothesis that the three equations were equivalent. The agreement between the three equations was evaluated by linear regression and Bland and Altman analysis. Bland and Altman analysis showed similar agreement between the three equations. The biases and precisions were -4.8±51, -1.3±50, and 8.2±44 for CG, MDRDs, and CKD-EPI equations, respectively (P>0.05). The precisions were similar for the three equations (P>0.05). The percentages of outliers at ±30% were 44%, 45%, and 49% for CG, MDRDs, and CKD-EPI, respectively (P>0.05). Regarding the high percentage of outliers, the use of these equations cannot be recommended in ICU patients. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  8. Impact on creatinine renal clearance by the interplay of multiple renal transporters: a case study with INCB039110.

    Science.gov (United States)

    Zhang, Yan; Warren, Mark S; Zhang, Xuexiang; Diamond, Sharon; Williams, Bill; Punwani, Naresh; Huang, Jane; Huang, Yong; Yeleswaram, Swamy

    2015-04-01

    Serum creatinine is commonly used as a marker of renal function, but increases in serum creatinine might not represent changes in glomerular filtration rate (GFR). INCB039110 (2-(3-(4-(7H-pyrrolo[2,3-day]pyrimidin-4-yl)-1H-pyrazol-1-yl)-1-(1-(3-fluoro-2-(trifluoromethyl)isonicotinoyl)piperidin-4-yl)azetidin-3-yl)acetonitrile) is an inhibitor of the Janus kinases (JAKs) with selectivity for JAK1. In a phase 1 study, a modest and reversible increase in serum creatinine was observed after treatment with INCB039110. However, a dedicated renal function study with INCB039110, assessed by iohexol plasma clearance, conducted in healthy volunteers indicated no change in GFR. In vitro studies were therefore conducted to investigate the interaction of INCB039110 with five transporters that are likely involved in the renal clearance of creatinine. Cell systems expressing individual or multiple transporters were used, including a novel quintuple-transporter model OAT2/OCT2/OCT3/MATE1/MATE2-K. INCB039110 potently inhibited OCT2-mediated uptake of creatinine as well as MATE1-/MATE2-K-mediated efflux of creatinine. Given the interactions of INCB039110 with multiple transporters affecting creatinine uptake and efflux, an integrated system expressing all five transporters was sought; in that system, INCB039110 caused a dose-dependent decrease in transcellular transport of creatinine with weaker net inhibition compared with the effects on individual transporters. In summary, a molecular mechanism for the increase in serum creatinine by INCB039110 has been established. These studies also underline the limitations of using serum creatinine as a marker of renal function. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.

  9. Creatinine Change on Vasoconstrictors as Mortality Surrogate in Hepatorenal Syndrome: Systematic Review & Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Justin M Belcher

    Full Text Available Hepatorenal syndrome is a severe complication of cirrhosis and associates with significant mortality. Vasoconstrictor medications improve renal function in patients with hepatorenal syndrome. However, it is unclear to what extent changes in serum creatinine during treatment may act as a surrogate for changes in mortality. We have performed a meta-analysis of randomized trials of vasoconstrictors assessing the association between changes in serum creatinine, taken as a continuous variable, and mortality, both while on treatment and during the follow-up period for survivors.The electronic databases of PubMed, Web of Science and Embase were searched for randomized trials evaluating the efficacy of vasoconstrictor therapy for treatment of HRS type 1 or 2. The relative risk (RR for mortality was calculated against delta creatinine. The proportion of treatment effect explained (PTE was calculated for delta creatinine.Seven trials enrolling 345 patients were included. The correlation between delta creatinine and ln (RR was moderately good (R2 = 0.61. The intercept and parameter estimate indicated a fall in creatinine while on treatment of 1 mg/dL resulted in a 27% reduction in RR for mortality compared to the control arm. In patients surviving the treatment period, a fall in creatinine while on treatment of 1 mg/dL resulted in a 16% reduction in RR for post-treatment mortality during follow-up. The PTE of delta creatinine for overall mortality was 0.91 and 0.26 for post-treatment mortality.Changes in serum creatinine in response to vasoconstrictor therapy appear to be a valid surrogate for mortality, even in the period following the completion of treatment.

  10. Creatinine Change on Vasoconstrictors as Mortality Surrogate in Hepatorenal Syndrome: Systematic Review & Meta-Analysis

    Science.gov (United States)

    Belcher, Justin M.; Coca, Steven G.; Parikh, Chirag R.

    2015-01-01

    Background and Aims Hepatorenal syndrome is a severe complication of cirrhosis and associates with significant mortality. Vasoconstrictor medications improve renal function in patients with hepatorenal syndrome. However, it is unclear to what extent changes in serum creatinine during treatment may act as a surrogate for changes in mortality. We have performed a meta-analysis of randomized trials of vasoconstrictors assessing the association between changes in serum creatinine, taken as a continuous variable, and mortality, both while on treatment and during the follow-up period for survivors. Methods The electronic databases of PubMed, Web of Science and Embase were searched for randomized trials evaluating the efficacy of vasoconstrictor therapy for treatment of HRS type 1 or 2. The relative risk (RR) for mortality was calculated against delta creatinine. The proportion of treatment effect explained (PTE) was calculated for delta creatinine. Results Seven trials enrolling 345 patients were included. The correlation between delta creatinine and ln (RR) was moderately good (R2 = 0.61). The intercept and parameter estimate indicated a fall in creatinine while on treatment of 1 mg/dL resulted in a 27% reduction in RR for mortality compared to the control arm. In patients surviving the treatment period, a fall in creatinine while on treatment of 1 mg/dL resulted in a 16% reduction in RR for post-treatment mortality during follow-up. The PTE of delta creatinine for overall mortality was 0.91 and 0.26 for post-treatment mortality. Conclusions Changes in serum creatinine in response to vasoconstrictor therapy appear to be a valid surrogate for mortality, even in the period following the completion of treatment. PMID:26295585

  11. Variability of creatinine measurements in clinical laboratories: results from the CRIC study.

    Science.gov (United States)

    Joffe, Marshall; Hsu, Chi-yuan; Feldman, Harold I; Weir, Matthew; Landis, J R; Hamm, L Lee

    2010-01-01

    Estimating equations using serum creatinine (SCr) are often used to assess glomerular filtration rate (GFR). Such creatinine (Cr)-based formulae may produce biased estimates of GFR when using Cr measurements that have not been calibrated to reference laboratories. In this paper, we sought to examine the degree of this variation in Cr assays in several laboratories associated with academic medical centers affiliated with the Chronic Renal Insufficiency Cohort (CRIC) Study; to consider how best to correct for this variation, and to quantify the impact of such corrections on eligibility for participation in CRIC. Variability of Cr is of particular concern in the conduct of CRIC, a large multicenter study of subjects with chronic renal disease, because eligibility for the study depends on Cr-based assessment of GFR. A library of 5 large volume plasma specimens from apheresis patients was assembled, representing levels of plasma Cr from 0.8 to 2.4 mg/dl. Samples from this library were used for measurement of Cr at each of the 14 CRIC laboratories repetitively over time. We used graphical displays and linear regression methods to examine the variability in Cr, and used linear regression to develop calibration equations. We also examined the impact of the various calibration equations on the proportion of subjects screened as potential participants who were actually eligible for the study. There was substantial variability in Cr assays across laboratories and over time. We developed calibration equations for each laboratory; these equations varied substantially among laboratories and somewhat over time in some laboratories. The laboratory site contributed the most to variability (51% of the variance unexplained by the specimen) and variation with time accounted for another 15%. In some laboratories, calibration equations resulted in differences in eligibility for CRIC of as much as 20%. The substantial variability in SCr assays across laboratories necessitates calibration

  12. Stability of BUN and creatinine determinations on the Siemens Advia 1800 analyzer.

    Science.gov (United States)

    Qin, Jia; Wang, Huiying; Rets, Anton; Harari, Saul; Alexis, Herol; Eid, Ikram; Pincus, Matthew R

    2013-11-01

    Serum creatinine values of patients tend to change as a result of the use of different blanks used for creatinine determinations on the Advia 1650. After upgrading the analyzer to the Advia 1800, creatinine values tended to be more reproducible. As part of a quality assurance investigation to test the reproducibilities of creatinine values, we determined serial creatinine values in the sera of 13 patients whose initial values were either in the reference range or elevated (range 0.58-7.8 mg/dl). These values were determined concurrently with serum blood urea nitrogen (BUN) determinations (range 6.0-84.4 mg/dl) as these two analytes are used together in evaluation of renal function. We determined BUN and creatinine values, using the glutamate dehydrogenase lined enzyme assay system and the Jaffe method, respectively. We find that all values for creatinine on samples stored at 4 °C were reproducible as were the corresponding BUN values, which is revealed by low values for the coefficients of variation (CVs), that is, mean CV of 4.55% for creatinine and 2.52% for BUN. One sample with relatively high CV (10.6%) for creatinine was found to have an initial value of 1.1 mg/dl, in the reference range; but, on repeat determinations, the obtained levels were as high as 1.5 mg/dl, above the reference range. BUN values for this sample remained in the reference range, suggesting that no renal disease was present. We conclude that creatinine and BUN determinations are stable, but occasional spurious creatinine values can occur on the Advia 1800 analyzer. © 2013 Wiley Periodicals, Inc.

  13. Evaluation of estimated creatinine clearance before steady state in acute kidney injury by creatinine kinetics.

    Science.gov (United States)

    Yashiro, Masatomo; Ochiai, Miyuki; Fujisawa, Nao; Kadoya, Yuko; Kamata, Tadashi

    2012-08-01

    A simple method to calculate estimated creatinine clearance using two serum creatinine concentration (Cr) values in acute kidney injury (AKI) was developed (eCrCl-AKI). We aimed to evaluate its accuracy and to clarify its contribution to the classification of AKI. We validated the errors in eCrCl-AKI in a simulation study after various reductions in creatinine clearance (CrCl) at various levels of chronic kidney disease (CKD). We compared the eCrCl-AKI-based classification of RIFLE criteria with the Cr-based classification or that proposed by Waikar and Bonventre. The regression equations of eCrCl-AKI on time were determined and Cr values were reconstructed by creatinine kinetics substituting CrCl with eCrCl-AKI in actual patients. Most errors in eCrCl-AKI were relatively small (from -13.6 to +7.9%) with the exception of two Cr values that straddled the changing trend of Cr. The classification according to RIFLE criteria based on Cr was unstable and did not enable adequate classification, especially in milder reductions of CrCl with advanced CKD. The classification based on eCrCl-AKI was stable and enabled adequate classification. There were good agreements between measured Cr and reconstructed Cr with eCrCl-AKI. The regression equations of eCrCl-AKI revealed changes of renal function that were unexpected only from fluctuations of Cr. eCrCl-AKI can provide relatively accurate estimates for fluctuating CrCl. eCrCl-AKI enables more stable and earlier classification of AKI than Cr, at least in the simulation study. The more widespread use of eCrCl-AKI in actual clinical settings of AKI is necessary to evaluate this formula.

  14. Elevated serum creatinine and hyponatraemia as prognostic factors in canine acute pancreatitis.

    Science.gov (United States)

    Marchetti, V; Gori, E; Lippi, I; Luchetti, E; Manca, M L; Pierini, A

    2017-11-01

    To evaluate prognostic factors for canine acute pancreatitis (AP) based on clinical and laboratory data that can be easily assessed in veterinary practice. Retrospective study between January 2010 and December 2013. The diagnosis of AP was based on clinical signs and an abnormal SNAP® cPL™ test result, concurrently with an ultrasound pattern suggestive of pancreatitis. Dogs were divided into survivors and non-survivors. We evaluated 12 clinical and laboratory parameters: respiratory rate, rectal temperature, white blood cells, haematocrit, total serum proteins, albumin, creatinine, cholesterol, total and ionised calcium, sodium and potassium. Clinical and clinicopathological data were statistically compared between survivors and non-survivors. A value of P  212 μmol/L (2.4 mg/dL) were associated significantly with poor prognosis. Azotaemia (OR 12.5; 95% confidence interval (CI) 1.32-118.48) and hyponatraemia (OR 4.9; 95% CI 1.36-17.64) were associated with increased risk of death. In dogs with AP, hyponatraemia and azotaemia seem to be significantly associated with an increased risk of death. © 2017 Australian Veterinary Association.

  15. Can preoperative serum level of creatinine predict new-onset atrial fibrillation in non-diabetic male patients undergoing open heart surgery? A retrograde view.

    Directory of Open Access Journals (Sweden)

    Seyed Jalil Mirhosseini

    2013-12-01

    Full Text Available Renal dysfunction is a risk marker in patients who candidate for coronary artery bypass graft (CABG. Renal disorder is associated with prolonged stays in intensive care unit and hospital, morbidity and mortality. Aim of this study is specific evaluation of association between preoperative creatinine (Cr with atrial fibrillation (AF after elective off-pump CABG in non-diabetic male patients with normal ejection fraction. Two hundred non-diabetic male patients with normal ejection fraction undergoing elective off pump CABG surgery enrolled in this cross-sectional study and were stratified by present or absence of postoperative atrial fibrillation: patients with postoperative new-onset atrial fibrillation (n=100 as group 1 and patients without new-onset postoperative atrial fibrillation as group 2 (n=100. Preoperative serological test of the participants, such as serum creatinine, were recorded in their medical dossiers. Data were analyzed in SPSS-16 software and tested for association between atrial fibrillation with creatinine level by using student t test, chi-square test or logistic regression. Cr level in patients with and without AF three days before surgery were 1.8±0.3 and 1.0±0.4 respectively (P value for Cr=0.00. On surgical day, mean Cr level in patients with and without AF were 1.6±0.2 and 1.1±0.5 respectively (P value for Cr = 0.00. Of the 100, male patients with postoperative AF, duration and frequency of recurrence of AF were not associated with Cr at three days before surgery and on surgical days (P>0.05. Patients with postoperative AF had unsuitable status of renal function compare to patients without AF; however, preoperative serum creatinine cannot associate with duration and frequency of recurrence of AF.

  16. Positive Impact of Nutritional Interventions on Serum Symmetric Dimethylarginine and Creatinine Concentrations in Client-Owned Geriatric Cats.

    Directory of Open Access Journals (Sweden)

    Jean A Hall

    Full Text Available A prospective study was conducted in client-owned geriatric cats to evaluate the short- term effects of a test food on serum symmetric dimethylarginine (SDMA and creatinine (Cr concentrations. Test food contained functional lipids (fish oil, antioxidants (vitamins C and E, L-carnitine, botanicals (vegetables, highly bioavailable protein, and amino acid supplements. Cats (n = 80 were fed either test food or owner's-choice foods (non-nutritionally controlled cohort. Cats were included based on age (≥ 9 years, indoor only, neutered, and free of chronic disease. At baseline, all cats had serum Cr concentrations within the reference interval. Renal function biomarkers and urinalysis results at baseline and after consuming test food or owner's-choice foods for 3 and 6 months were evaluated. Cats consuming test food showed significant decreases in serum Cr and BUN concentrations across time. Overall, cats consuming owner's-choice foods showed significant increases in serum SDMA concentrations at 3 and 6 months compared with baseline (P ≤ 0.05, whereas in cats consuming test food serum SDMA concentrations did not change. At baseline or during the 6-month feeding trial, 23 (28.8% cats had increased serum SDMA, but normal serum Cr consistent with IRIS Stage 1 chronic kidney disease. This included 6 cats fed test food and 17 cats fed owner's-choice foods. In the 6 cats fed test food, serum SDMA decreased in 3 cats and remained stable in 1 cat, whereas in the 17 cats fed owner's-choice foods, serum SDMA increased in 13 cats and decreased or remained stable in 4 cats. The increase in serum SDMA concentration was significant (P = 0.02 only for cats fed owner's-choice foods. These results suggest that nonazotemic cats with elevated serum SDMA (early renal insufficiency when fed a food designed to promote healthy aging are more likely to demonstrate stable renal function compared with cats fed owner's-choice foods. Cats fed owner's-choice foods were more

  17. An evaluation of hyperkalemia and serum creatinine elevation associated with different dosage levels of outpatient trimethoprim-sulfamethoxazole with and without concomitant medications.

    Science.gov (United States)

    Gentry, Chris A; Nguyen, Ann T

    2013-12-01

    Adverse events associated with high-dose trimethoprim-sulfamethoxazole (TMP-SMX) for outpatient infections, particularly those likely caused by community-acquired methicillin-resistant Staphylococcus aureus, have not been adequately characterized. Describe hyperkalemia and acute renal injury associated with high-dose TMP-SMX. An electronic medical record database retrospective study was conducted of outpatients receiving high-dose or low-dose TMP-SMX, comparing the incidences of hyperkalemia and acute renal injury. Of 6162 patients, more developed hyperkalemia (3.06% vs 1.05%, P high-dose TMP-SMX group. Variables independently associated with hyperkalemia included age >58 years (odds ratio [OR] = 3.44; 95% CI = 1.86-7.0; P high-dose TMP-SMX prescribed (OR = 2.92; 95% CI = 1.85-4.60; P creatinine (OR = 45.1; 95% CI = 21.7-93.2; P high-dose TMP-SMX prescribed (OR = 3.70; 95% CI = 1.70-8.12; P = .0012), and baseline elevated serum creatinine (OR = 2110; 95% CI = 724-7980; P creatinine and potassium concentrations should be monitored in outpatients receiving high-dose TMP-SMX.

  18. Use of Multiple Imputation Method to Improve Estimation of Missing Baseline Serum Creatinine in Acute Kidney Injury Research

    Science.gov (United States)

    Peterson, Josh F.; Eden, Svetlana K.; Moons, Karel G.; Ikizler, T. Alp; Matheny, Michael E.

    2013-01-01

    Summary Background and objectives Baseline creatinine (BCr) is frequently missing in AKI studies. Common surrogate estimates can misclassify AKI and adversely affect the study of related outcomes. This study examined whether multiple imputation improved accuracy of estimating missing BCr beyond current recommendations to apply assumed estimated GFR (eGFR) of 75 ml/min per 1.73 m2 (eGFR 75). Design, setting, participants, & measurements From 41,114 unique adult admissions (13,003 with and 28,111 without BCr data) at Vanderbilt University Hospital between 2006 and 2008, a propensity score model was developed to predict likelihood of missing BCr. Propensity scoring identified 6502 patients with highest likelihood of missing BCr among 13,003 patients with known BCr to simulate a “missing” data scenario while preserving actual reference BCr. Within this cohort (n=6502), the ability of various multiple-imputation approaches to estimate BCr and classify AKI were compared with that of eGFR 75. Results All multiple-imputation methods except the basic one more closely approximated actual BCr than did eGFR 75. Total AKI misclassification was lower with multiple imputation (full multiple imputation + serum creatinine) (9.0%) than with eGFR 75 (12.3%; Pcreatinine) (15.3%) versus eGFR 75 (40.5%; P<0.001). Multiple imputation improved specificity and positive predictive value for detecting AKI at the expense of modestly decreasing sensitivity relative to eGFR 75. Conclusions Multiple imputation can improve accuracy in estimating missing BCr and reduce misclassification of AKI beyond currently proposed methods. PMID:23037980

  19. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  20. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  1. Evaluation the short term effects on serum creatinine concentration in patients with normal renal function, mild and moderate renal insufficiency after intravenous injection of gadopentetate dimeglumine

    International Nuclear Information System (INIS)

    Luo Jian; Liu Jing; Wang Xiaoying; Yang Xuedong; Jiang Xuexiang

    2010-01-01

    Objective: To explore the effects of gadopentetate dimeglumine injection on renal function. Methods: The study included 623 consecutive patients. Their serum creatinine concentrations before and within 3 days after injection of gadopentetate dimeglumine were analyzed. Their eGFR (estimated glomerular filtration rate) were calculated. Patients were divided into two groups according to their injection dose: group received single dose and group received double dose. Patients in each group were subdivided into three subgroups according to their eGFR: subgroup of normal renal function, subgroup of mild renal insufficiency and subgroup of moderate renal insufficiency. Paried sample t test and group design paired sample Rank Sum test were used for statistical analysis. Results: There was no adverse reaction or occurrence of acute renal insufficiency. The mean level of serum creatinine dropped from (74.0± 17.2) μmol/L to (71.5±19.0) μmol/L (t=5.39, P 0.05) in subgroup of mild renal insufficiency under group received double dose and increased from (118.3±15.3) μmol/L to (135.7±8.5) μmol/L (t=2.02, P<0.05) in subgroup of moderate renal insufficiency under group received double dose, the mean level of serum creatinine dropped in all other subgroups. Conclusions: Single dose gadopentetate dimeglumine is safe for patients with normal renal function and mild, moderate renal insufficiency in short term, but patients with abnormal renal function should be followed up after double dose injection. (authors)

  2. Proximal Tubular Secretion of Creatinine by Organic Cation Transporter OCT2 in Cancer Patients

    Science.gov (United States)

    Ciarimboli, Giuliano; Lancaster, Cynthia S.; Schlatter, Eberhard; Franke, Ryan M.; Sprowl, Jason A.; Pavenstädt, Hermann; Massmann, Vivian; Guckel, Denise; Mathijssen, Ron H. J.; Yang, Wenjian; Pui, Ching-Hon; Relling, Mary V.; Herrmann, Edwin; Sparreboom, Alex

    2012-01-01

    Purpose Knowledge of transporters responsible for the renal secretion of creatinine is key to a proper interpretation of serum creatinine and/or creatinine clearance as markers of renal function in cancer patients receiving chemotherapeutic agents. Experimental Design Creatinine transport was studied in transfected HEK293 cells in vitro and in wildtype mice and age-matched organic cation transporter 1 and 2-deficient [Oct1/2(−/−)] mice ex vivo and in vivo. Clinical pharmacogenetic and transport inhibition studies were done in two separate cohorts of cancer patients. Results Compared to wildtype mice, creatinine clearance was significantly impaired in Oct1/2(−/−) mice. Furthermore, creatinine inhibited organic cation transport in freshly-isolated proximal tubules from wild-type mice and humans, but not in those from Oct1/2(−/−) mice. In a genetic-association analysis (n=590), several polymorphisms around the OCT2/SLC22A2 gene locus, including rs2504954 (P=0.000873), were significantly associated with age-adjusted creatinine levels. Furthermore, in cancer patients (n=68), the OCT2 substrate cisplatin caused an acute elevation of serum creatinine (P=0.0083), consistent with inhibition of an elimination pathway. Conclusions Collectively, this study shows that OCT2 plays a decisive role in the renal secretion of creatinine. This process can be inhibited by OCT2 substrates, which impair the usefulness of creatinine as a marker of renal function. PMID:22223530

  3. Existing creatinine-based equations overestimate glomerular filtration rate in Indians.

    Science.gov (United States)

    Kumar, Vivek; Yadav, Ashok Kumar; Yasuda, Yoshinari; Horio, Masaru; Kumar, Vinod; Sahni, Nancy; Gupta, Krishan L; Matsuo, Seiichi; Kohli, Harbir Singh; Jha, Vivekanand

    2018-02-01

    Accurate estimation of glomerular filtration rate (GFR) is important for diagnosis and risk stratification in chronic kidney disease and for selection of living donors. Ethnic differences have required correction factors in the originally developed creatinine-based GFR estimation equations for populations around the world. Existing equations have not been validated in the vegetarian Indian population. We examined the performance of creatinine and cystatin-based GFR estimating equations in Indians. GFR was measured by urinary clearance of inulin. Serum creatinine was measured using IDMS-traceable Jaffe's and enzymatic assays, and cystatin C by colloidal gold immunoassay. Dietary protein intake was calculated by measuring urinary nitrogen appearance. Bias, precision and accuracy were calculated for the eGFR equations. A total of 130 participants (63 healthy kidney donors and 67 with CKD) were studied. About 50% were vegetarians, and the remainder ate meat 3.8 times every month. The average creatinine excretion were 14.7 mg/kg/day (95% CI: 13.5 to 15.9 mg/kg/day) and 12.4 mg/kg/day (95% CI: 11.2 to 13.6 mg/kg/day) in males and females, respectively. The average daily protein intake was 46.1 g/day (95% CI: 43.2 to 48.8 g/day). The mean mGFR in the study population was 51.66 ± 31.68 ml/min/1.73m 2 . All creatinine-based eGFR equations overestimated GFR (p < 0.01 for each creatinine based eGFR equation). However, eGFR by CKD-EPI Cys was not significantly different from mGFR (p = 0.38). The CKD-EPI Cys exhibited lowest bias [mean bias: -3.53 ± 14.70 ml/min/1.73m 2 (95% CI: -0.608 to -0.98)] and highest accuracy (P 30 : 74.6%). The GFR in the healthy population was 79.44 ± 20.19 (range: 41.90-134.50) ml/min/1.73m 2 . Existing creatinine-based GFR estimating equations overestimate GFR in Indians. An appropriately powered study is needed to develop either a correction factor or a new equation for accurate assessment of kidney function in the

  4. Measurement of creatinine in human plasma using a functional porous polymer structure sensing motif

    Science.gov (United States)

    Nanda, Sitansu Sekhar; An, Seong Soo A; Yi, Dong Kee

    2015-01-01

    In this study, a new method for detecting creatinine was developed. This novel sensor comprised of two ionic liquids, poly-lactic-co-glycolic acid (PLGA) and 1-butyl-3-methylimidazolium (BMIM) chloride, in the presence of 2′,7′-dichlorofluorescein diacetate (DCFH-DA). PLGA and BMIM chloride formed a functional porous polymer structure (FPPS)-like structure. Creatinine within the FPPS rapidly hydrolyzed and released OH−, which in turn converted DCFH-DA to DCFH, developing an intense green color or green fluorescence. The conversion of DCFH to DCF+ resulted in swelling of FPPS and increased solubility. This DCF+-based sensor could detect creatinine levels with detection limit of 5 µM and also measure the creatinine in blood. This novel method could be used in diagnostic applications for monitoring individuals with renal dysfunction. PMID:26347475

  5. Plasma NGAL predicts early acute kidney injury no earlier than s-creatinine or cystatin C in severely burned patients.

    Science.gov (United States)

    Rakkolainen, Ilmari; Vuola, Jyrki

    2016-03-01

    Neutrophil gelatinase-associated lipocalin (NGAL) is a novel biomarker used in acute kidney injury (AKI) diagnostics. Studies on burn patients have highlighted it as a promising biomarker for early detection of AKI. This study was designed to discover whether plasma NGAL is as a biomarker superior to serum creatinine and cystatin C in detecting AKI in severely burned patients. Nineteen subjects were enrolled from March 2013 to September 2014 in the Helsinki Burn Centre. Serum creatinine, cystatin C, and plasma NGAL were collected from the patients at admission and every 12h during the first 48h and thereafter daily until seven days following admission. AKI was defined by acute kidney injury network criteria. Nine (47%) developed AKI during their intensive care unit stay and two (11%) underwent renal replacement therapy. All biomarkers were significantly higher in the AKI group but serum creatinine- and cystatin C values reacted more rapidly to changes in kidney function than did plasma NGAL. Plasma NGAL tended to rise on average 72h±29h (95% CI) later in patients with early AKI than did serum creatinine. Area-under-the-curve values calculated for each biomarker were 0.92 for serum creatinine, 0.87 for cystatin C, and 0.62 for plasma NGAL predicting AKI by the receiver-operating-characteristic method. This study demonstrated serum creatinine and cystatin C as faster and more reliable biomarkers than plasma NGAL in detecting early AKI within one week of injury in patients with severe burns. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  6. The analytical change in plasma creatinine that constitutes a biologic/physiologic change.

    Science.gov (United States)

    Toffaletti, John G; Hammett-Stabler, Catherine A; Gearhart, Margaret; Roy Choudhury, Kingshuk; Handel, Elizabeth A

    2016-08-01

    had good precision, the ENZ method had the best precision, such that a change of 0.07mg/dL (6μmol/L) in serial creatinine concentrations up to 1.5mg/dL on a patient could indicate a biologic change had occurred. For the alkaline picrate methods, a measured change of creatinine of 0.23mg/dL for AP1 or 0.11mg/dL for AP2 would indicate that a physiologic change in serum/plasma creatinine has occurred. While a definite biologic change may simply represent daily variations, detecting a biologic change in creatinine more rapidly could impact the ability of creatinine to detect early and clinically significant changes in renal function. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Comparison of Glomerular Filtration Rate Estimation from Serum Creatinine and Cystatin C in HNF1A-MODY and Other Types of Diabetes

    Directory of Open Access Journals (Sweden)

    Magdalena Szopa

    2015-01-01

    Full Text Available Introduction. We previously showed that in HNF1A-MODY the cystatin C-based glomerular filtration rate (GFR estimate is higher than the creatinine-based estimate. Currently, we aimed to replicate this finding and verify its clinical significance. Methods. The study included 72 patients with HNF1A-MODY, 72 with GCK-MODY, 53 with type 1 diabetes (T1DM, 70 with type 2 diabetes (T2DM, and 65 controls. Serum creatinine and cystatin C levels were measured. GFR was calculated from creatinine and cystatin C using the CKD-EPI creatinine equation (eGRF-cr and CKD-EPI cystatin C equation (eGFR-cys, respectively. Results. Cystatin C levels were lower (p<0.001 in the control (0.70±0.13 mg/L, HNF1A (0.75±0.21, and GCK (0.72±0.16 mg/L groups in comparison to those with either T1DM (0.87±0.15 mg/L or T2DM (0.9±0.23 mg/L. Moreover, eGFR-cys was higher than eGRF-cr in HNF1A-MODY, GCK-MODY, and the controls (p=0.004; p=0.003; p<0.0001. This corresponded to 8.9 mL/min/1.73 m2, 9.7 mL/min/1.73 m2, and 16.9 mL/min/1.73 m2 of difference. Additionally, T1DM patients had higher eGFR-cr than eGFR-cys (11.6 mL/min/1.73 m2; p=0.0004; no difference occurred in T2DM (p=0.91. Conclusions. We confirmed that eGFR-cys values in HNF1A-MODY patients are higher compared to eGFR-cr. Some other differences were also described in diabetic groups. However, none of them appears to be clinically relevant.

  8. [A patient with high creatinine levels but no renal failure: reversed autodialysis in a patient with a ruptured bladder].

    Science.gov (United States)

    Raeymaeckers, Steven; Tosi, Maurizio; Van Bael, Kobe; Brussaard, Carola; De Mey, Johan

    2016-01-01

    In case of a ruptured bladder with urine leakage into the peritoneal cavity 'reversed autodialysis' can occur, in which urea and creatinine diffuse back into the bloodstream via the peritoneum. This causes clinical signs of pseudorenal failure, with raised concentrations of creatinine and urea. The urea/creatinine ratio does not change. A 34-year-old female patient experienced increasing abdominal pain 3 days after laparoscopic myomectomy. Acute renal failure was suspected because of increased serum concentrations of creatinine and urea, but no cause could be found. There was a build-up of fluid in the abdominal cavity, which proved to be urine originating from an iatrogenic rupture of the bladder. Serum levels normalised following repair of the rupture. If serum creatinine levels rise rapidly following abdominal surgery or blunt abdominal trauma the bladder should be examined for possible perforation, particularly if the abdominal dimension increases. A ruptured bladder leading to pseudorenal failure is an indication for rapid surgical intervention.

  9. Comparison of cystatin C- and creatinine-based estimated glomerular filtration rate to predict coronary heart disease risk in Japanese patients with obesity and diabetes.

    Science.gov (United States)

    Ito, Ryo; Yamakage, Hajime; Kotani, Kazuhiko; Wada, Hiromichi; Otani, Sumire; Yonezawa, Kazuya; Ogo, Atsushi; Okajima, Taiichiro; Adachi, Masahiro; Araki, Rika; Yoshida, Kazuro; Saito, Miho; Nagaoka, Tadasu; Toyonaga, Tetsushi; Tanaka, Tsuyoshi; Yamada, Tsutomu; Ota, Itsuro; Oishi, Mariko; Miyanaga, Fumiko; Shimatsu, Akira; Satoh-Asahara, Noriko

    2015-01-01

    The aim of this study is to determine which indicator of chronic kidney disease most closely correlates with 10-year Framingham coronary heart disease (CHD) risk among serum creatinine, serum cystatin C (S-CysC), urine albumin-creatinine ratio (UACR), estimated creatinine-based GFRs (eGFRcre), and estimated CysC-based GFRs (eGFRcys) in patients with obesity and diabetes. Serum creatinine, S-CysC, UACR, and cardio-ankle vascular index (CAVI) were examined in 468 outpatients with obesity and type 2 diabetes, free of severe renal dysfunction or previous history of cardiovascular disease, as a cross-sectional survey using baseline data from the multi-centered Japan Diabetes and Obesity Study. S-CysC and eGFRcys had significantly stronger correlations with the 10-year Framingham CHD risk than serum creatinine, eGFRcre, and UACR (creatinine, ρ = 0.318; S-CysC, ρ = 0.497; UACR, ρ = 0.174; eGFRcre, ρ = -0.291; eGFRcys, ρ = -0.521; P obesity and diabetes.

  10. Empirical relationships among oliguria, creatinine, mortality, and renal replacement therapy in the critically ill.

    Science.gov (United States)

    Mandelbaum, Tal; Lee, Joon; Scott, Daniel J; Mark, Roger G; Malhotra, Atul; Howell, Michael D; Talmor, Daniel

    2013-03-01

    The observation periods and thresholds of serum creatinine and urine output defined in the Acute Kidney Injury Network (AKIN) criteria were not empirically derived. By continuously varying creatinine/urine output thresholds as well as the observation period, we sought to investigate the empirical relationships among creatinine, oliguria, in-hospital mortality, and receipt of renal replacement therapy (RRT). Using a high-resolution database (Multiparameter Intelligent Monitoring in Intensive Care II), we extracted data from 17,227 critically ill patients with an in-hospital mortality rate of 10.9 %. The 14,526 patients had urine output measurements. Various combinations of creatinine/urine output thresholds and observation periods were investigated by building multivariate logistic regression models for in-hospital mortality and RRT predictions. For creatinine, both absolute and percentage increases were analyzed. To visualize the dependence of adjusted mortality and RRT rate on creatinine, the urine output, and the observation period, we generated contour plots. Mortality risk was high when absolute creatinine increase was high regardless of the observation period, when percentage creatinine increase was high and the observation period was long, and when oliguria was sustained for a long period of time. Similar contour patterns emerged for RRT. The variability in predictive accuracy was small across different combinations of thresholds and observation periods. The contour plots presented in this article complement the AKIN definition. A multi-center study should confirm the universal validity of the results presented in this article.

  11. Impact of Gate 99mTc DTPA GFR, Serum Creatinine and Urea in Diagnosis of Patients with Chronic Kidney Failure

    Science.gov (United States)

    Miftari, Rame; Nura, Adem; Topçiu-Shufta, Valdete; Miftari, Valon; Murseli, Arbenita; Haxhibeqiri, Valdete

    2017-01-01

    Aim: The aim of this study was determination of validity of 99mTcDTPA estimation of GFR for early detection of chronic kidney failure Material and methods: There were 110 patients (54 males and 56 females) with kidney disease referred for evaluation of renal function at UCC of Kosovo. All patients were included in two groups. In the first group were included 30 patients confirmed with renal failure, whereas in the second group were included 80 patients with other renal disease. In study were included only patients with ready results of creatinine, urea and glucose in the blood serum. For estimation of GFR we have used the Gate GFR DTPA method. The statistical data processing was conducted using statistical methods such as arithmetic average, the student t-test, percentage or rate, sensitivity, specificity and accuracy of the test. Results: The average age of all patients was 36 years old. The average age of female was 37 whereas of male 35. Patients with renal failure was significantly older than patients with other renal disease (p<0.005). Renal failure was found in 30 patients (27.27%). The concentration of urea and creatinine in blood serum of patients with renal failure were significantly higher than in patients with other renal disease (P< 0.00001). GFR in patients with renal failure were significantly lower than in patients with other renal disease, 51.75 ml/min (p<0.00001). Sensitivity of uremia and creatininemia for detection of renal failure were 83.33%, whereas sensitivity of 99mTcDTPA GFR was 100%. Specificity of uraemia and creatininemia were 63% whereas specificity of 99mTcDTPA GFR was 47.5%. Diagnostic accuracy of blood urea and creatinine in detecting of renal failure were 69%, whereas diagnostic accuracy of 99mTcDTPA GFR was 61.8%. Conclusion: Gate 99mTc DTPA scintigraphy in collaboration with biochemical tests are very sensitive methods for early detection of patients with chronic renal failure. PMID:28883673

  12. Post-standardization of routine creatinine assays: are they suitable for clinical applications.

    Science.gov (United States)

    Jassam, Nuthar; Weykamp, Cas; Thomas, Annette; Secchiero, Sandra; Sciacovelli, Laura; Plebani, Mario; Thelen, Marc; Cobbaert, Christa; Perich, Carmen; Ricós, Carmen; Paula, Faria A; Barth, Julian H

    2017-05-01

    Introduction Reliable serum creatinine measurements are of vital importance for the correct classification of chronic kidney disease and early identification of kidney injury. The National Kidney Disease Education Programme working group and other groups have defined clinically acceptable analytical limits for creatinine methods. The aim of this study was to re-evaluate the performance of routine creatinine methods in the light of these defined limits so as to assess their suitability for clinical practice. Method In collaboration with the Dutch External Quality Assurance scheme, six frozen commutable samples, with a creatinine concentration ranging from 80 to 239  μmol/L and traceable to isotope dilution mass spectrometry, were circulated to 91 laboratories in four European countries for creatinine measurement and estimated glomerular filtration rate calculation. Two out of the six samples were spiked with glucose to give high and low final concentrations of glucose. Results Results from 89 laboratories were analysed for bias, imprecision (%CV) for each creatinine assay and total error for estimated glomerular filtration rate. The participating laboratories used analytical instruments from four manufacturers; Abbott, Beckman, Roche and Siemens. All enzymatic methods in this study complied with the National Kidney Disease Education Programme working group recommended limits of bias of 5% above a creatinine concentration of 100  μmol/L. They also did not show any evidence of interference from glucose. In addition, they also showed compliance with the clinically recommended %CV of ≤4% across the analytical range. In contrast, the Jaffe methods showed variable performance with regard to the interference of glucose and unsatisfactory bias and precision. Conclusion Jaffe-based creatinine methods still exhibit considerable analytical variability in terms of bias, imprecision and lack of specificity, and this variability brings into question their clinical utility

  13. Evaluation of serum angiopoietin-II in HCV related ...

    African Journals Online (AJOL)

    Hoda A. Abd-El-Moety

    2011-08-30

    Aug 30, 2011 ... blood urea, serum creatinine, serum uric acid, ALT, AST, total and direct bilirubin ... factor, cryoglobulins31–33 and urinary albumin creatinine ratio ..... reported that VEGF stimulates increased synthesis of collage- nase by ...

  14. Two low-cost digital camera-based platforms for quantitative creatinine analysis in urine.

    Science.gov (United States)

    Debus, Bruno; Kirsanov, Dmitry; Yaroshenko, Irina; Sidorova, Alla; Piven, Alena; Legin, Andrey

    2015-10-01

    In clinical analysis creatinine is a routine biomarker for the assessment of renal and muscular dysfunctions. Although several techniques have been proposed for a fast and accurate quantification of creatinine in human serum or urine, most of them require expensive or complex apparatus, advanced sample preparation or skilled operators. To circumvent these issues, we propose two home-made platforms based on a CD Spectroscope (CDS) and Computer Screen Photo-assisted Technique (CSPT) for the rapid assessment of creatinine level in human urine. Both systems display a linear range (r(2) = 0.9967 and 0.9972, respectively) from 160 μmol L(-1) to 1.6 mmol L(-1) for standard creatinine solutions (n = 15) with respective detection limits of 89 μmol L(-1) and 111 μmol L(-1). Good repeatability was observed for intra-day (1.7-2.9%) and inter-day (3.6-6.5%) measurements evaluated on three consecutive days. The performance of CDS and CSPT was also validated in real human urine samples (n = 26) using capillary electrophoresis data as reference. Corresponding Partial Least-Squares (PLS) regression models provided for mean relative errors below 10% in creatinine quantification. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Timely Diagnosis of Acute Kidney Injury Using Kinetic eGFR and the Creatinine Excretion to Production Ratio, E/eG - Creatinine Can Be Useful!

    Science.gov (United States)

    Endre, Zoltán H; Pianta, Timothy J; Pickering, John W

    2016-01-01

    Post transplant repeated measurements of urine volume and serum creatinine (sCr) are used to assess kidney function. Under non-steady state conditions, repeated measurement of sCr allows calculation of the kinetic estimated GFR (KeGFR). Additional measurement of urinary creatinine allows the calculation of the creatinine excretion to (estimated) production ratio (E/eG). We hypothesized that post-transplant KeGFR and E/eG would predict delayed graft function (DGF), as early as 4 h and outperform a validated clinical model at 12 h. This was a retrospective analysis of prospectively acquired data in a study of 56 recipients of deceased-donor kidney transplant. We assessed predictive performance with the area under the receiver operator characteristic curve (AUC) and the added value to a clinical model with integrated discrimination improvement analysis. At 4 h, the AUC for E/eG was 0.87 (95% CI 0.77-0.96) and for KeGFR 0.69 (95% CI 0.56-0.83). Both E/eG and KeGFR improved the risk prediction of a clinical model for DGF by 32 and 18%, and for non-DGF by 17 and 10%, respectively. While E/eG had better predictive performance of DGF than KeGFR, KeGFR might also facilitate perioperative management including drug dosing after kidney transplantation. Together these measurements may facilitate the possibility of conducting trials of early intervention to ameliorate the adverse effects of ischaemia-reperfusion injury on long-term DGF. © 2016 S. Karger AG, Basel.

  16. Modified Creatinine Index and the Risk of Bone Fracture in Patients Undergoing Hemodialysis: The Q-Cohort Study.

    Science.gov (United States)

    Yamada, Shunsuke; Taniguchi, Masatomo; Tokumoto, Masanori; Yoshitomi, Ryota; Yoshida, Hisako; Tatsumoto, Narihito; Hirakata, Hideki; Fujimi, Satoru; Kitazono, Takanari; Tsuruya, Kazuhiko

    2017-08-01

    Hemodialysis patients are at increased risk for bone fracture and sarcopenia. There is close interplay between skeletal muscle and bone. However, it is still unclear whether lower skeletal muscle mass increases the risk for bone fracture. Cross-sectional study and prospective longitudinal cohort study. An independent cohort of 78 hemodialysis patients in the cross-sectional study and 3,030 prevalent patients undergoing maintenance hemodialysis prospectively followed up for 4 years. Skeletal muscle mass measured by bioelectrical impedance analysis (BIA) and modified creatinine index, an estimate of skeletal muscle mass based on age, sex, Kt/V for urea, and serum creatinine level. Bone fracture at any site. In the cross-sectional study, modified creatinine index was significantly correlated with skeletal muscle mass measured by BIA. During a median follow-up of 3.9 years, 140 patients had bone fracture. When patients were divided into sex-specific quartiles based on modified creatinine index, risk for bone fracture estimated by a Fine-Gray proportional subdistribution hazards model with all-cause death as a competing risk was significantly higher in the lower modified creatinine index quartiles (Q1 and Q2) compared to the highest modified creatinine index quartile (Q4) as the reference value in both sexes (multivariable-adjusted HRs for men were 7.81 [95% CI, 2.63-23.26], 5.48 [95% CI, 2.08-14.40], 2.24 [95% CI, 0.72-7.00], and 1.00 [P for trend creatinine index; no data for residual kidney function and fracture sites and causes. Modified creatinine index was correlated with skeletal muscle mass measured by BIA. Lower modified creatinine index was associated with increased risk for bone fracture in male and female hemodialysis patients. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  17. Validity of Serum Cystatin C as an Early and Accurate Marker of Glomerular Filtration Rate in type 1 Diabetes Mellitus Patients

    International Nuclear Information System (INIS)

    Fathy, H.A.; Fathy, M.A.

    2017-01-01

    The present study aims at exploring the clinical validity of measuring cystatin C for the early and accurate assessment of GFR (as compared to measuring serum creatinine or β2 microglobulin) in patients suffering from type 1 diabetes mellitus who are at risk of developing diabetic nephropathy as well as those who have already developed the condition. This study included 80 subjects who were further subdivided into two groups: Control group (1) which comprised 20 healthy age and sex matched children. Patient group (2) comprised 60 patients of both sexes properly diagnosed with type 1 diabetes. The patients were further subdivided into 3 subgroups according albumin levels in their 24 hour urine : Group 2a: 20 patients who were considered normo-albumin uric. Group 2b: 20 patients who were considered micro-albumin uric. Group 2c: 20 patients who were considered macro - albumin uric. All subjects were subjected to the estimation of serum creatinine level as well as serum β2 microglobulin and serum cystatin C levels. They were also subjected to Isotope renogram using "9"9"mTc- diethylene triamine pentaacetic acid (DTPA) single injection technique for accurate measurement of glomerular filtration rate (GFR). A positive correlation was observed between each of serum creatinine, β2 microglobulin, cystatin C with albumin in 24 hr urine in all the patient subgroups and this correlation was highly significant. However, the correlation between serum cystatin C levels in the diabetic patients and albumin in 24 hr urine was higher than that observed for either serum creatinine or serum β2 microglobulin. Cystatin C had the highest negative correlation with GFR (as measured by "9"9"mTc-DTPA clearance) compared to either serum creatinine or serum β 2 microglobulin in group II patients. It can be concluded that cystatin C could act as an early and accurate marker of GFR and renal function in patients with type 1 diabetes mellitus at risk of developing or who have already

  18. A meta-analysis of genome-wide data from five European isolates reveals an association of COL22A1, SYT1, and GABRR2 with serum creatinine level

    NARCIS (Netherlands)

    C. Pattaro (Cristian); A. de Grandi (Alessandro); V. Vitart (Veronique); C. Hayward (Caroline); A. Franke (Andre); Y.S. Aulchenko (Yurii); A. Johansson (Åsa); S.H. Wild (Sarah); S.A. Melville (Scott); A.J. Isaacs (Aaron); O. Polasek (Ozren); D. Ellinghaus (David); I. Kolcic (Ivana); U. Nöthlings (Ute); L. Zgaga (Lina); T. Zemunik (Tatijana); C. Gnewuch (Carsten); S. Schreiber (Stefan); S. Campbell (Susan); N. Hastie (Nick); M. Boban (Mladen); T. Meitinger (Thomas); B.A. Oostra (Ben); P. Riegler (Peter); C. Minelli (Cosetta); A.F. Wright (Alan); H. Campbell (Harry); C.M. van Duijn (Cornelia); U. Gyllensten (Ulf); J.F. Wilson (James); M. Krawczak (Michael); I. Rudan (Igor); P.P. Pramstaller (Peter Paul)

    2010-01-01

    textabstractBackground: Serum creatinine (SCR) is the most important biomarker for a quick and non-invasive assessment of kidney function in population-based surveys. A substantial proportion of the inter-individual variability in SCR level is explicable by genetic factors.Methods: We performed a

  19. Urine and serum fetuin-A levels in patients with urolithiasis.

    Science.gov (United States)

    Arora, Rajat; Abrol, Nitin; Antonisamy, B; Vanitha, S; Chandrasingh, J; Kumar, Santosh; Kekre, Nitin; Devasia, Antony

    2017-01-01

    Fetuin-A is a glycoprotein secreted by liver and has been shown to inhibit extraosseous mineralization. Urolithiasis may be a manifestation in the urinary tract due to fetuin deficiency in urine. The objective of this study was to compare the 24-h urine and serum fetuin-A levels of patients with and without urolithiasis. Serum and 24-h urine fetuin-A levels were measured in 41 patients with bilateral, multiple, or recurrent urinary tract calculi (Group A) and 41 matched controls with no calculi (Group B). Fetuin levels were measured by enzyme linked immunosorbent assay. Serum and urine fetuin-A levels in the two groups were compared. The median (range) 24-h urine fetuin-A value in Group A was 11.9 (1.12-221) mg/day and in Group B was 37.7 (1.28-125) mg/day. This difference was statistically significant (Mann-Whitney test, P = 0.0169). The median (range) serum fetuin-A in Group A was 0.67 (0.05-2.68) g/L and in Group B was 0.99 (0.01-5.5) g/L. The difference between serum values in the two arms was not statistically significant (Mann-Whitney test, P = 0.1817). However, the serum creatinine-adjusted mean log serum fetuin and urine fetuin were significantly different in the two arms ( P = 0.003). The mean ± standard deviation (range) serum creatinine in Group A was 0.98 ± 0.25 (0.56-1.58) mg% and in Group B was 0.83 ± 0.16 (0.58-1.18) mg% (two sample t -test, P = 0.0031). Patients with urolithiasis have lower urine fetuin-A and creatinine-adjusted serum fetuin-A levels.

  20. Estimating Renal Function in the Elderly Malaysian Patients Attending Medical Outpatient Clinic: A Comparison between Creatinine Based and Cystatin-C Based Equations.

    Science.gov (United States)

    Jalalonmuhali, Maisarah; Elagel, Salma Mohamed Abouzriba; Tan, Maw Pin; Lim, Soo Kun; Ng, Kok Peng

    2018-01-01

    To assess the performance of different GFR estimating equations, test the diagnostic value of serum cystatin-C, and compare the applicability of cystatin-C based equation with serum creatinine based equation for estimating GFR (eGFR) in comparison with measured GFR in the elderly Malaysian patients. A cross-sectional study recruiting volunteered patients 65 years and older attending medical outpatient clinic. 51 chromium EDTA ( 51 Cr-EDTA) was used as measured GFR. The predictive capabilities of Cockcroft-Gault equation corrected for body surface area (CGBSA), four-variable Modification of Diet in Renal Disease (4-MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations using serum creatinine (CKD-EPIcr) as well as serum cystatin-C (CKD-EPIcys) were calculated. A total of 40 patients, 77.5% male, with mean measured GFR 41.2 ± 18.9 ml/min/1.73 m 2 were enrolled. Mean bias was the smallest for 4-MDRD; meanwhile, CKD-EPIcr had the highest precision and accuracy with lower limit of agreement among other equations. CKD-EPIcys equation did not show any improvement in GFR estimation in comparison to CKD-EPIcr and MDRD. The CKD-EPIcr formula appears to be more accurate and correlates better with measured GFR in this cohort of elderly patients.

  1. Serum Chemerin Levels Are Associated with Abdominal Visceral Fat in Type 2 Diabetes.

    Science.gov (United States)

    Han, Juyoung; Kim, So Hun; Suh, Young Ju; Lim, Hyun Ae; Shin, Heekyoung; Cho, Soon Gu; Kim, Chei Won; Lee, Seung Youn; Lee, Dae Hyung; Hong, Seongbin; Kim, Yong Seong; Nam, Moon-Suk

    2016-06-01

    Chemerin is a recently identified adipokine suggested to play a role in obesity and its metabolic complications. The relationship between visceral obesity and serum chemerin levels in type 2 diabetes (T2DM) is unknown and may differ from that of subjects without diabetes. Therefore, we evaluated whether serum chemerin was associated with visceral abdominal obesity in patients with T2DM. A total of 218 Korean patients with T2DM were enrolled and metabolic parameters, abdominal visceral and subcutaneous fat areas, and serum chemerin levels were measured. Serum chemerin level showed positive correlation with fasting insulin, HOMA-IR, serum triglyceride, serum creatinine, urine albumin/creatinine ratio, high-sensitivity C-reactive protein (hsCRP), fibrinogen, abdominal visceral fat area, visceral to subcutaneous fat area ratio, and negatively correlation with high density lipoprotein cholesterol and creatinine clearance (CCr) after adjusting for age, gender and body mass index. Multiple linear stepwise regression analysis showed that abdominal visceral fat area (β = 0.001, P abdominal visceral fat area, serum triglyceride, hsCRP and fibrinogen and lower level of CCr in patients with T2DM. Serum chemerin may be used as a biomarker of visceral adiposity and chemerin may play a role in inflammation, decreased renal function, and increased cardiovascular risk in T2DM.

  2. Evaluation of the Urine Protein/Creatinine Ratio Measured with the Dipsticks Clinitek Atlas PRO 12.

    Science.gov (United States)

    Hermida, Fernando J; Soto, Sonia; Benitez, Alfonso J

    2016-01-01

    Screening for urine proteins is recommended for the detection of albuminuria in high risk groups. The aim of this study was to compare the Clinitek Atlas PRO12 reagent urine strip with quantitative methods for the determination of protein/creatinine ratio and to evaluate the usefulness of the semi-quantitative Clinitek Atlas PRO12 reagent urine strip as a tool in the early detection of albuminuria among the general population. Six hundred first morning urine specimens were collected from outpatients with various clinical conditions. The results showed that the test data for the urine dipstick Clinitek Atlas PRO12 show good agreement with the quantitative measurement of protein, creatinine and protein/creatinine ratio. In addition, this study shows that 97.2% of the samples which gave "normal" protein/creatinine ratios by the semi-quantitative method, showed albumin/creatinine ratio < 30 mg/g by the quantitative methods. Our results show that Clinitek Atlas PRO12 reagent strips can be used for the purposes of albuminuria screening in the general population.

  3. Serum cystatin C as an earlier predictor of acute kidney injury than serum creatinine in preterm neonates with respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Noha Ahmed Abdelaal

    2017-01-01

    Full Text Available In this study, we aimed to evaluate serum cystatin C (sCysC as an early predictor of acute kidney injury (AKI in preterm neonates with respiratory distress syndrome (RDS. Sixty preterm neonates diagnosed with RDS and 40 healthy controls (28–36 weeks admitted to the neonatal Intensive Care Unit were investigated. AKI was defined on the 3rd day of life (DOL-3 as an increase in serum creatinine (sCr of >0.3 mg/dL from baseline (the lowest previous sCr. sCysC levels were measured on DOL-1, -3 and -7. Of the 60 neonates with RDS, 24 (40% developed AKI. Five patients (79.17% were classified as AKI Network (AKIN-1 and 19 patients (20.83%, as AKIN-2. At DOL-3, the mean sCysC values were significantly higher among neonates with RDS and AKI (1.68 ± 0.37 compared with controls (0.79 ± 0.83 and those with RDS and no AKI (0.85 ± 0.20 (P <0.001. sCysC levels significantly increased among neonates with AKI from DOL-3 to DOL-7 (P = 0.002. The sCr values showed no significant difference between those with RDS with AKI, RDS, and no AKI or control groups at DOL-1 and -3. Only as late as DOL-7, the mean values of sCr were higher among neonates with AKI compared with no AKI and controls (P <0.001. The receiver operating characteristic curves area under the curve was 0.97 for predicting the development of AKI within 72 h (P = 0.001. With the best cutoff value of ≥1.28 mg/L, the sensitivity and specificity of sCysC for detecting AKI within 72 h were 100 and 83.3%, respectively. In conclusion, sCysC is an early marker for AKI in neonates with RDS.

  4. Did Creatinine Standardization Give Benefits to the Evaluation of Glomerular Filtration Rate?

    OpenAIRE

    Piéroni, Laurence; Bargnoux, Anne-Sophie; Cristol, Jean-Paul; Cavalier, Etienne; Delanaye, Pierre

    2017-01-01

    During the last decade, a lot of efforts has been made to improve the evaluation of renal functions. Measured Glomerular Filtration Rate (GFR) remains the only valuable test to confirm or confute the status of chronic kidney disease (CKD) and is recommended by Kidney Disease Global Outcomes guidelines when estimation of GFR is not reliable. However, in routine clinical practice, serum creatinine remains the one of the most prescribed biological parameters and is an undeniable factor, alone or...

  5. Measured glomerular filtration rate does not improve prediction of mortality by cystatin C and creatinine.

    Science.gov (United States)

    Sundin, Per-Ola; Sjöström, Per; Jones, Ian; Olsson, Lovisa A; Udumyan, Ruzan; Grubb, Anders; Lindström, Veronica; Montgomery, Scott

    2017-04-01

    Cystatin C may add explanatory power for associations with mortality in combination with other filtration markers, possibly indicating pathways other than glomerular filtration rate (GFR). However, this has not been firmly established since interpretation of associations independent of measured GFR (mGFR) is limited by potential multicollinearity between markers of GFR. The primary aim of this study was to assess associations between cystatin C and mortality, independent of mGFR. A secondary aim was to evaluate the utility of combining cystatin C and creatinine to predict mortality risk. Cox regression was used to assess the associations of cystatin C and creatinine with mortality in 1157 individuals referred for assessment of plasma clearance of iohexol. Since cystatin C and creatinine are inversely related to mGFR, cystatin C - 1 and creatinine - 1 were used. After adjustment for mGFR, lower cystatin C - 1 (higher cystatin C concentration) and higher creatinine - 1 (lower creatinine concentration) were independently associated with increased mortality. When nested models were compared, avoiding the potential influence of multicollinearity, the independence of the associations was supported. Among models combining the markers of GFR, adjusted for demographic factors and comorbidity, cystatin C - 1 and creatinine - 1 combined explained the largest proportion of variance in associations with mortality risk ( R 2  = 0.61). Addition of mGFR did not improve the model. Our results suggest that both creatinine and cystatin C have independent associations with mortality not explained entirely by mGFR and that mGFR does not offer a more precise mortality risk assessment than these endogenous filtration markers combined. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  6. Detecting microalbuminuria by urinary albumin/creatinine concentration ratio

    DEFF Research Database (Denmark)

    Jensen, J S; Clausen, P; Borch-Johnsen, K

    1997-01-01

    BACKGROUND: Microalbuminuria, i.e. a subclinical increase of the albumin excretion rate in urine, may be a novel atherosclerotic risk factor. This study aimed to test whether microalbuminuria can be identified by measurement of urinary albumin concentration or urinary albumin/creatinine concentra......BACKGROUND: Microalbuminuria, i.e. a subclinical increase of the albumin excretion rate in urine, may be a novel atherosclerotic risk factor. This study aimed to test whether microalbuminuria can be identified by measurement of urinary albumin concentration or urinary albumin/creatinine...... not included. Urinary albumin (Ualb) and creatinine (Ucreat) concentrations were measured in an overnight collected sample by enzyme-linked immunosorbent and colorimetric assays, respectively. Urinary albumin excretion rate (UAER) and urinary albumin/creatinine concentration ratio (Ualb/Ucreat) were calculated......, and 73%, 97%, and 73% for Ualb/Ucreat, respectively. CONCLUSIONS: It is concluded that measurement of the albumin/creatinine concentration ratio is a specific and quite sensitive alternative to measurement of the urinary albumin excretion rate in timed collections, when screening for microalbuminuria....

  7. Effect of ultraviolet light on creatinine measurement in jaundiced specimens

    International Nuclear Information System (INIS)

    Nisbet, J.A.; D'Souza, R.

    1986-01-01

    During initial evaluation of a creatinine method using the RA-1000 analyser, experiments with addition of bilirubin indicated negligible interference. However the finding of a 'zero' creatinine value in an extremely jaundiced specimen prompted to re-examine the method. In contrast to earlier findings with normal plasma containing added bilirubin, the authors found that plasma from moderately or severely jaundiced patients gave creatinine values lower than those obtained with a reference method. Since bilirubin has been implicated in the interference, the authors studied the effect of destroying bilirubin with ultraviolet light to see if this provided a practical solution to the problem. (Auth.)

  8. Estimating Renal Function in the Elderly Malaysian Patients Attending Medical Outpatient Clinic: A Comparison between Creatinine Based and Cystatin-C Based Equations

    Directory of Open Access Journals (Sweden)

    Maisarah Jalalonmuhali

    2018-01-01

    Full Text Available Background. To assess the performance of different GFR estimating equations, test the diagnostic value of serum cystatin-C, and compare the applicability of cystatin-C based equation with serum creatinine based equation for estimating GFR (eGFR in comparison with measured GFR in the elderly Malaysian patients. Methods. A cross-sectional study recruiting volunteered patients 65 years and older attending medical outpatient clinic. 51 chromium EDTA (51Cr-EDTA was used as measured GFR. The predictive capabilities of Cockcroft-Gault equation corrected for body surface area (CGBSA, four-variable Modification of Diet in Renal Disease (4-MDRD, and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI equations using serum creatinine (CKD-EPIcr as well as serum cystatin-C (CKD-EPIcys were calculated. Results. A total of 40 patients, 77.5% male, with mean measured GFR 41.2±18.9 ml/min/1.73 m2 were enrolled. Mean bias was the smallest for 4-MDRD; meanwhile, CKD-EPIcr had the highest precision and accuracy with lower limit of agreement among other equations. CKD-EPIcys equation did not show any improvement in GFR estimation in comparison to CKD-EPIcr and MDRD. Conclusion. The CKD-EPIcr formula appears to be more accurate and correlates better with measured GFR in this cohort of elderly patients.

  9. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  10. Creatinine plasma at uncontrolled type 2 diabetes mellitus and controlled type 2 diabetes mellitus patients at primary health care in Binjai city, Indonesia

    Science.gov (United States)

    Rusdiana; Savira, M.; Syahputra, M.; Santoso, A.

    2018-03-01

    The aim of the study knowing the comparison creatinine plasma levels at uncontrolled type 2 diabetes mellitus and controlled type 2 diabetes mellitus patients at Primary Health Care in Binjai city of North Sumatera in Indonesia. This cross-sectional study was conductedon 40 type 2 Diabetes Mellitus patients who attended Primary Health Care in Binjai. Patients with age > 40 years old, (both sexes) were included in the study. We recorded different demographic parameter as age, Body Mass Index, Blood Pressure, and personal history status. And we examined the biochemicalparameters including Hba1c, Fasting Blood Sugar Levels (FBL) and creatinine serum. We separated into two groups base on HbA1c test, controlled type 2 diabetes mellitus and uncontrolled type 2 diabetes mellitus. We measured FBL by using the portable measuring instrument, and Thamrin clinical laboratory measured Hba1c, andwe measured creatinine plasmaby spectrophotometry in Biochemistry laboratory. With statistical analysis using T-test found that there was asignificant differencein creatinine plasma levels between uncontrolled type 2 diabetes mellitus with controlled type 2 diabetes mellitus (p<0.005).

  11. SERUM PARAOXONASE ACTIVITY IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    Saritha Gadicherla

    2017-12-01

    Full Text Available BACKGROUND Serum paraoxonase is an enzyme synthesised in the liver. It is known to prevent atherosclerosis by inhibiting oxidation of lowdensity lipoprotein. Renal transplant recipients have increased tendency for developing atherosclerosis and cardiovascular disease. Reduced activity of serum paraoxonase contributes to accelerated atherosclerosis and increased cardiovascular complications in these patients. The aim of this study was to estimate serum paraoxonase activity in renal transplant recipients and compare it with healthy controls. MATERIALS AND METHODS 30 renal transplant recipients and 30 age and sex matched healthy controls were taken for the study. Serum paraoxonase activity, blood urea, serum creatinine and uric acid were estimated in these groups. The serum paraoxonase activity was correlated with urea, creatinine and uric acid levels. RESULTS Serum paraoxonase activity was reduced in renal transplant recipients compared to healthy controls. There was a negative correlation between paraoxonase activity and the levels of urea, creatinine and uric acid levels. CONCLUSION In this study, the paraoxonase activity was reduced in renal transplant recipients compared to controls. The increased cardiovascular disease in these patients could be due to reduced paraoxonase activity.

  12. The soluble receptor for vitamin B12 uptake (sCD320) increases during pregnancy and occurs in higher concentration in urine than in serum

    DEFF Research Database (Denmark)

    Abuyaman, Omar; Andreasen, Birgitte H; Kronborg, Camilla

    2013-01-01

    BACKGROUND: Cellular uptake of vitamin B12 (B12) demands binding of the vitamin to transcobalamin (TC) and recognition of TC-B12 (holoTC) by the receptor CD320, a receptor expressed in high quantities on human placenta. We have identified a soluble form of CD320 (sCD320) in serum and here we...... gestational weeks 17-41. sCD320, holoTC, total TC and complex formation between holoTC and sCD320 were measured by in-house ELISA methods, while creatinine was measured on the automatic platform Cobas 6000. Size exclusion chromatography was performed on a Superdex 200 column. RESULTS: Median (range) of serum...... was around two fold higher than in serum. Urinary sCD320/creatinine ratio correlated with serum sCD320 and reached a peak median level of 53 (30-101) pmol/mmol creatinine (week 35). sCD320 present in serum and urine showed the same elution pattern upon size exclusion chromatography. CONCLUSION: We report...

  13. Accuracy of point-of-care serum creatinine devices for detecting patients at risk of contrast-induced nephropathy: a critical overview.

    Science.gov (United States)

    Martínez Lomakin, Felipe; Tobar, Catalina

    2014-12-01

    Contrast-induced nephropathy (CIN) is a common event in hospitals, with reported incidences ranging from 1 to 30%. Patients with underlying kidney disease have an increased risk of developing CIN. Point-of-care (POC) creatinine devices are handheld devices capable of providing quantitative data on a patient's kidney function that could be useful in stratifying preventive measures. This overview aims to synthesize the current evidence on diagnostic accuracy and clinical utility of POC creatinine devices in detecting patients at risk of CIN. Five databases were searched for diagnostic accuracy studies or clinical trials that evaluated the usefulness of POC devices in detecting patients at risk of CIN. Selected articles were critically appraised to assess their individual risk of bias by the use of standard criteria; 13 studies were found that addressed the diagnostic accuracy or clinical utility of POC creatinine devices. Most studies incurred a moderate to high risk of bias. Overall concordance between POC devices and reference standards (clinical laboratory procedures) was found to be moderate, with 95% limits of agreement often lying between -35.4 and +35.4 µmol/L (-0.4 and +0.4 mg/dL). Concordance was shown to decrease with worsening kidney function. Data on the clinical utility of these devices were limited, but a significant reduction in time to diagnosis was reported in two studies. Overall, POC creatinine devices showed a moderate concordance with standard clinical laboratory creatinine measurements. Several biases could have induced optimism in these estimations. Results obtained from these devices may be unreliable in cases of severe kidney failure. Randomized trials are needed to address the clinical utility of these devices.

  14. Ranitidine has no influence on tubular creatinine secretion

    NARCIS (Netherlands)

    van den Berg, J. G.; Koopman, M. G.; Arisz, L.

    1996-01-01

    Oral cimetidine competitively inhibits tubular secretion of creatinine. We investigated the potential of oral ranitidine, a comparable H2-receptor antagonist, to block tubular creatinine secretion. In 10 healthy subjects, clearances of inulin and endogenous creatinine were simultaneously measured

  15. Chemiluminescence of creatinine/H2O2/Co(2+) and its application for selective creatinine detection.

    Science.gov (United States)

    Hanif, Saima; John, Peter; Gao, Wenyue; Saqib, Muhammad; Qi, Liming; Xu, Guobao

    2016-01-15

    Creatinine is an important biomarker in clinical diagnosis and biomonitoring programs as well as urinary metabolomic/metabonomics research. Current methods are either nonselective, time consuming or require heavy and expensive instruments. In this study, chemiluminescence of creatinine with hydrogen peroxide has been reported for the first time, and its chemiluminescence is remarkably enhanced in the presence of cobalt ions. By utilizing these phenomena, we have developed a sensitive and selective chemiluminescence method for creatinine determination by coupling with flow injection analysis. The calibration curve is linear in the range of 1×10(-7)-3×10(-5)mol/L with a limit of detection (S/N=3) of 7.2×10(-8)mol/L, which is adequate for detecting creatinine in the clinically accepted range. The relative standard deviation for seven measurements of 3×10(-5)mol/L creatinine is 1.2%. The chemiluminescence method was then utilized to detect creatinine in human urine samples after simple dilution with water. It takes less than 1min each measurement and the recoveries for spiked urine samples were 100-103%. The interference study demonstrates that some common species in urine, such as amino acids, ascorbic acid and creatine, have negligible effects on creatinine detection. The present method does not use expensive instruments, enzymes and separation technique. This method has the advantages of sensitivity, selectivity, simplicity, rapidity, and low cost. It holds great promise for basic or comprehensive metabolic panel, drug screening, anti-dopping, and urinary metabolomic/metabonomics research. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Evaluation, including effects of storage and repeated freezing and thawing, of a method for measurement of urinary creatinine

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Kristiansen, J

    2003-01-01

    The aims of this study were to elucidate to what extent storage and repeated freezing and thawing influenced the concentration of creatinine in urine samples and to evaluate the method for determination of creatinine in urine. The creatinine method was based on the well-known Jaffe's reaction...... and measured on a COBAS Mira autoanalyser from Roche. The main findings were that samples for analysis of creatinine should be kept at a temperature of -20 degrees C or lower and frozen and thawed only once. The limit of detection, determined as 3 x SD of 20 determinations of a sample at a low concentration (6...

  17. KDIGO 2012 Clinical Practice Guideline CKD classification rules out creatinine clearance 24 hour urine collection?

    Science.gov (United States)

    Ognibene, A; Grandi, G; Lorubbio, M; Rapi, S; Salvadori, B; Terreni, A; Veroni, F

    2016-01-01

    The recent guideline for the evaluation and management of Chronic Kidney Disease recommends assessing GFR employing equations based on serum creatinine; despite this, creatinine clearance 24-hour urine collection is used routinely in many settings. In this study we compared the classification assessed from CrCl (creatinine clearance 24h urine collection) and e-GFR calculated with CKD-EPI or MDRD formulas. In this retrospective study we analyze consecutive laboratory data: creatinine clearance 24h urine collection, serum creatinine and demographic data such as sex and age from 15,777 patients >18 years of age collected from 2011 to 2013 in our laboratory at Careggi Hospital. The results were then compared to the estimated GFR calculated with the equations according to the recent treatment guidelines. Consecutive and retrospective laboratory data (creatinine clearance 24h urine collection, serum creatinine and, demographic data such as sex and age) from 15,777 patients >18 years of age seen at Careggi Hospital were collected. Comparison between e-GFR calculated with CKD-EPI or MDRD formulas and GFR according CrCl determinations and bias [95% CI] were 11.34 [-47,4/70.1] and 11.4 [-50.2/73] respectively. The concordance for 18/65 years aged group when compared with e-GFR classification between MDRD vs CKDEPI, MDRD vs CrCl and CKD-EPI vs CrCl were 0.78, 0.34, and 0.41 respectively, while in the 65/110years aged group the concordance Kappas were 0.84, 0.38, and 0.36 respectively. The use of CrCl provides a different classification than the estimation of GFR using a prediction equation. The CrCl is unreliable when it is necessary to identify CKD subjects with decrease of GFR of 5ml/min/1.73m(2)/year. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Verification of serum reference intervals for free light chains in a local South African population.

    Science.gov (United States)

    Zemlin, Annalise E; Rensburg, Megan A; Ipp, Hayley; Germishuys, Jurie J; Erasmus, Rajiv T

    2013-11-01

    Monoclonal serum free light chain measurements are used to follow up and manage patients with monoclonal gammopathies, and abnormal serum free light chain ratios are associated with risk of progression in certain diseases. We aimed to validate the reference intervals in our population. Reference intervals for κ and λ free light chains were established on 120 healthy adults. Creatinine levels were measured to exclude renal dysfunction and serum protein electrophoresis was performed. All creatinine values were within normal limits. After exclusion of subjects with abnormal serum protein electrophoreses, 113 subjects were available for analysis. The 95% reference interval was 6.3-20.6 mg/L for κ free light chains, 8.7-25.9 mg/L for λ free light chains and 0.46-1.23 for free light chain ratio. Most of the values fell within the manufacturer's recommended limits and therefore could be used for our population.

  19. Creatinine

    Science.gov (United States)

    ... to affect the kidneys, such as diabetes or high blood pressure , then creatinine and BUN tests may be used to monitor ... the ribs, near where the kidneys are located High blood pressure The creatinine blood test may be ordered, along with a ...

  20. Measurement of purine derivatives and creatinine in urine by HPLC

    International Nuclear Information System (INIS)

    Piani, B.; Fabro, C.; Susmel, P.

    2004-01-01

    Two HPLC methods to measure the purine derivatives (PD, including allantoin, uric acid, hypoxanthine and xanthine) and creatinine content in urine are described. PD separation and quantification were achieved using two Spherisorb ODS 2 reversed phase columns connected in series (4.6 x 250 mm) and a Spherisorb ODS 2 Waters pre-column and a Perkin Elmer pump with an auto sampler. The mobile phase was NH 4 H 2 PO 4 :NH 4 H 2 PO 4 -acetonitrile (80:20), which was used at a flow rate of 0.8 ml/min and the detection wavelength was at 190 nm. The average recoveries of standard compounds added to urine samples were satisfactory (92-106%) and the low detection limits (0.7-3.4 μM) permitted the precise determination of these compounds in urine. Separation and quantification of creatinine was achieved using one Spherisorb ODS 2 reversed phase column (4.6 x 250 mm) and one Spherisorb ODS 2 Waters pre-column and a Perkin Elmer pump with an auto sampler. The mobile phase was NH 4 H 2 PO 4 :NH 4 H 2 PO 4 -acetonitrile (80:20), used at a flow rate of 1.00 ml/min and the detection was at 190 nm. The mean recovery (3 measurements) of standard solution added to urine samples was 101%; detection limit was 7.9 μM. (author)

  1. Creatinine, diet, micronutrients, and arsenic methylation in West Bengal, India.

    Science.gov (United States)

    Basu, Arin; Mitra, Soma; Chung, Joyce; Guha Mazumder, D N; Ghosh, Nilima; Kalman, David; von Ehrenstein, Ondine S; Steinmaus, Craig; Liaw, Jane; Smith, Allan H

    2011-09-01

    Ingested inorganic arsenic (InAs) is methylated to monomethylated (MMA) and dimethylated metabolites (DMA). Methylation may have an important role in arsenic toxicity, because the monomethylated trivalent metabolite [MMA(III)] is highly toxic. We assessed the relationship of creatinine and nutrition--using dietary intake and blood concentrations of micronutrients--with arsenic metabolism, as reflected in the proportions of InAS, MMA, and DMA in urine, in the first study that incorporated both dietary and micronutrient data. We studied methylation patterns and nutritional factors in 405 persons who were selected from a cross-sectional survey of 7,638 people in an arsenic-exposed population in West Bengal, India. We assessed associations of urine creatinine and nutritional factors (19 dietary intake variables and 16 blood micronutrients) with arsenic metabolites in urine. Urinary creatinine had the strongest relationship with overall arsenic methylation to DMA. Those with the highest urinary creatinine concentrations had 7.2% more arsenic as DMA compared with those with low creatinine (p creatinine concentration was the strongest biological marker of arsenic methylation efficiency, and therefore should not be used to adjust for urine concentration in arsenic studies. The new finding that animal fat intake has a positive relationship with MMA% warrants further assessment in other studies. Increased MMA% was also associated, to a lesser extent, with low serum selenium and folate.

  2. Association of Lead Exposure, Serum Uric Acid and Parameters of Renal Function in Nigerian Lead-Exposed Workers

    Directory of Open Access Journals (Sweden)

    DD Alasia

    2010-09-01

    Full Text Available Background: The presence of hyperuricemia and renal function impairment, especially in the absence of urate stone formation is strongly suggestive of lead nephropathy. The evaluation of this association is essential in areas where lead exposure is still prevalent and uncontrolled. Objective: To determine the relationship between serum uric acid and renal function indices in lead-exposed workers. Methods: A cross-sectional study of 190 adults with occupational lead exposure and 80 adults (comparison group, matched for age and sex was performed in Port Harcourt, South-south Nigeria. Blood lead was used as the biomarker of lead exposure while serum urea, serum creatinine, urine albumin (using urine albumin:creatinine ratio, estimated glomerular filtration rate (GFR and serum uric acid were the renal function indices measured. Results: Occupationally lead-exposed subjects had a significantly (p = 0.008 higher mean±SD blood lead levels (50.37±24.58 μg/dL than the comparison group (41.40±26.85. The mean±SD serum urea (8.6±2.3 mg/dL, creatinine (1.0±0.2 mg/dL and serum uric acid (4.6±1.2 mg/dL were significantly (p < 0.01 higher in the study subjects than the comparison group (7.6±2.4, 0.9±0.2, and 3.9±1.1 mg/dL, respectively. The mean±SD creatinine clearance was significantly (p = 0.002 lower in the study subjects than the comparison group (98.9±21.3 vs. 108.2±25.2 mL/min/1.72 m2. Serum uric acid level correlated positively with serum creatinine (r = 0.134 and negatively with GFR (r = ‑0.151. Conclusion: People with occupational lead exposure are at risk of developing hyperuricemia and renal impairment.

  3. Can baseline serum creatinine and e-GFR predict renal function outcome after augmentation cystoplasty in children?

    Science.gov (United States)

    Singh, Prempal; Bansal, Ankur; Sekhon, Virender; Nunia, Sandeep; Ansari, M S

    2018-01-01

    To assess cut-off value of creatinine and glomerular filtration rate for augmentation cystoplasty (AC) in paediatric age-group. Data of all paediatric-patients (Creatinine and e-GFR were assessed at the time of surgery, at 6 months and at last follow-up. Renal function deterioration was defined as increase in creatinine by ≥25% from baseline value or new-onset stage-3 CKD or worsening of CKD stage with pre-operative-CKD stage-3. ROCs were plotted using creatinine and e-GFR for AC. A total of 94 patients with mean-age 8.9 years were included. The mean creatinine and e-GFR were 1.33mg/dL and 57.68mL/min respectively. Out of 94 patients, AC was performed in 45 patients and in the remaining 49 patients AC was not done (control-group), as they were not willing for the same. Baseline patient's characteristics were comparable in both Groups. 22 underwent gastro-cystoplasty (GC) and 25 underwent ileo-cystoplasty (IC). Decline in renal function was observed in 15 (33.3%) patients of AC-group and in 31 (63.3%) patients of control-group. Patients having creatinine ≥1.54mg/dL (P=0.004, sensitivity (S) 63.6% and specificity (s) 90.5%) at baseline and e-GFR ≤46mL/min (P=0.000, S=100% and s=85.7%) at the time of surgery had significantly increased probability of renal function deterioration on follow-up after AC. e-GFR ≤46mL/min and creatinine ≥1.54mg/dL at time of surgery could serve as a predictor of renal function deterioration in AC in paediatric patients. Copyright® by the International Brazilian Journal of Urology.

  4. Monitoring renal function in children with Fabry disease: comparisons of measured and creatinine-based estimated glomerular filtration rate

    NARCIS (Netherlands)

    Tøndel, Camilla; Ramaswami, Uma; Aakre, Kristin Moberg; Wijburg, Frits; Bouwman, Machtelt; Svarstad, Einar

    2010-01-01

    Studies on renal function in children with Fabry disease have mainly been done using estimated creatinine-based glomerular filtration rate (GFR). The aim of this study was to compare estimated creatinine-based GFR (eGFR) with measured GFR (mGFR) in children with Fabry disease and normal renal

  5. Varying coefficients model with measurement error.

    Science.gov (United States)

    Li, Liang; Greene, Tom

    2008-06-01

    We propose a semiparametric partially varying coefficient model to study the relationship between serum creatinine concentration and the glomerular filtration rate (GFR) among kidney donors and patients with chronic kidney disease. A regression model is used to relate serum creatinine to GFR and demographic factors in which coefficient of GFR is expressed as a function of age to allow its effect to be age dependent. GFR measurements obtained from the clearance of a radioactively labeled isotope are assumed to be a surrogate for the true GFR, with the relationship between measured and true GFR expressed using an additive error model. We use locally corrected score equations to estimate parameters and coefficient functions, and propose an expected generalized cross-validation (EGCV) method to select the kernel bandwidth. The performance of the proposed methods, which avoid distributional assumptions on the true GFR and residuals, is investigated by simulation. Accounting for measurement error using the proposed model reduced apparent inconsistencies in the relationship between serum creatinine and GFR among different clinical data sets derived from kidney donor and chronic kidney disease source populations.

  6. Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group.

    Science.gov (United States)

    Delanghe, Joris R; Cobbaert, Christa; Galteau, Marie-Madeleine; Harmoinen, Aimo; Jansen, Rob; Kruse, Rolf; Laitinen, Päivi; Thienpont, Linda M; Wuyts, Birgitte; Weykamp, Cas; Panteghini, Mauro

    2008-01-01

    The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are described, in which 189 European laboratories analyzed serum creatinine in a commutable serum-based material, using analytical systems from seven companies. Values were targeted using isotope dilution gas chromatography/mass spectrometry. Results were tested on their compliance to a set of three criteria: trueness, i.e., no significant bias relative to the target value, between-laboratory variation and within-laboratory variation relative to the maximum allowable error. For the lower and intermediate level, values differed significantly from the target value in the Jaffe and the dry chemistry methods. At the high level, dry chemistry yielded higher results. Between-laboratory coefficients of variation ranged from 4.37% to 8.74%. Total error budget was mainly consumed by the bias. Non-compensated Jaffe methods largely exceeded the total error budget. Best results were obtained for the enzymatic method. The dry chemistry method consumed a large part of its error budget due to calibration bias. Despite the European IVD directive and the growing needs for creatinine standardization, an unacceptable inter-laboratory variation was observed, which was mainly due to calibration differences. The calibration variation has major clinical consequences, in particular in pediatrics, where reference ranges for serum and plasma creatinine are low, and in the estimation of glomerular filtration rate.

  7. LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers’ 24 Hour Urine

    Directory of Open Access Journals (Sweden)

    Hongwei Hou

    2012-01-01

    Full Text Available A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1×150 mm, 3.5 μm. The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v. Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of quantification of 0.99 ng/mL. The intra- and interday precision (RSD values were below 3%. The method was successfully applied to a bioequivalence study of creatinine in Chinese smokers and nonsmokers. The total cotinine in 24 h urine and cotinine : creatinine ratio were also positively associated (Pearson R=0.942, P<0.0001. However, cotinine : creatinine ratio varied significantly across smoking groups for the difference of individual. 24 h urinary cotinine was more appropriate for expressing correlation with tar than cotinine : creatinine ratio.

  8. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  9. The Relationship between Serum Hemoglobin and Creatinine Levels and Intra-Hospital Mortality and Morbidity in Acute Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Afsoon Fazlinezhad

    2014-09-01

    Full Text Available Background: Studies have shown that Glomerular Filtration Rate (GFR and Hemoglobin (Hb concentrations are two predictive values for ST-elevation Myocardial Infarction (MI mortality.. Objectives: This study aimed to investigate the relationship between GFR and Hb concentrations and intra-hospital mortality and electrocardiographic (ECG and echocardiographic abnormalities in ST-elevation MI patients admitted to a highly equipped hospital in Mashhad. The results will help define some factors to manage these patients more efficiently.. Patients and Methods: This descriptive study aimed to assess the relationship between Hb and GFR concentrations and mortality and morbidity among 294 randomly selected patients with ST-elevation MI. Echocardiography, ECG, and routine laboratory tests, including Hb and creatinine, were performed for all the patients. Then, the data were entered into the SPSS statistical software, version 16 and were analyzed using chi-square, t-test, and ANOVA. P < 0.05 was considered as statistically significant.. Results: Intra-hospital mortality rate was 10.5%. Besides, the results showed higher levels of serum blood sugar (P < 0.001, higher levels of creatinine (P < 0.001, lower levels of GFR (P < 0.001, lower ejection fraction (P < 0.001, higher grades of left ventricular diastolic dysfunction (P = 0.002, and lower mean Hb concentration (P = 0.022 in the dead compared to the alive cases. Besides, the patients with mechanical complications had lower Hb levels (P = 0.008. The results showed no significant relationship between creatinine level and mechanical and electrical complications (P = 0.430 and P = 0.095, respectively. However, ejection fraction was significantly associated with GFR (P = 0.016.. Conclusions: According to the results, low levels of Hb and GFR could predict mortality caused by ST-elevation MI and ECG abnormalities could notify intra-hospital death. Moreover, lower Hb levels were associated with mechanical

  10. GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffé, HPLC and enzymatic assays.

    Science.gov (United States)

    Tsikas, Dimitrios; Wolf, Alexander; Mitschke, Anja; Gutzki, Frank-Mathias; Will, Wolfgang; Bader, Michael

    2010-10-01

    In consideration of its relatively constant urinary excretion rate, creatinine in urine is a useful biochemical parameter to correct the urinary excretion rate of endogenous and exogenous biomolecules. Assays based on the reaction of creatinine and picric acid first reported by Jaffé in 1886 still belong to the most frequently used laboratory approaches for creatinine measurement in urine. Further analytical methods for creatinine include HPLC-UV, GC-MS, and LC-MS and LC-MS/MS approaches. In the present article we report on the development, validation and biomedical application of a new GC-MS method for the reliable quantitative determination of creatinine in human urine, plasma and serum. This method is based on the derivatization of creatinine (d(0)-Crea) and the internal standard [methyl-trideutero]creatinine (d(3)-Crea) with pentafluorobenzyl (PFB) bromide in the biological sample directly or after dilution with phosphate buffered saline, extraction of the reaction products with toluene and quantification in 1-μl aliquots of the toluene extract by selected-ion monitoring of m/z 112 for d(0)-Crea-PFB and m/z 115 for d(3)-Crea-PFB in the electron-capture negative-ion chemical ionization mode. The limit of detection of the method is 100 amol of creatinine. In an inter-laboratory study on urine samples from 100 healthy subjects, the GC-MS method was used to test the reliability of currently used Jaffé, enzymatic and HPLC assays in clinical and occupational studies. The results of the inter-laboratory study indicate that all three tested methods allow for satisfactory quantification of creatinine in human urine. The GC-MS method is suitable for use as a reference method for urinary creatinine in humans. In serum, creatine was found to contribute to creatinine up to 20% when measured by the present GC-MS method. The application of the GC-MS method can be extended to other biological samples such as saliva. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Requirement for specific gravity and creatinine adjustments for urinary steroids and luteinizing hormone concentrations in adolescents.

    Science.gov (United States)

    Singh, Gurmeet K S; Balzer, Ben W R; Desai, Reena; Jimenez, Mark; Steinbeck, Katharine S; Handelsman, David J

    2015-11-01

    Urinary hormone concentrations are often adjusted to correct for hydration status. We aimed to determine whether first morning void urine hormones in growing adolescents require adjustments and, if so, whether urinary creatinine or specific gravity are better adjustments. The study population was adolescents aged 10.1 to 14.3 years initially who provided fasting morning blood samples at 0 and 12 months (n = 343) and first morning urine every three months (n = 644). Unadjusted, creatinine and specific gravity-adjusted hormonal concentrations were compared by Deming regression and Bland-Altman analysis and grouped according to self-rated Tanner stage or chronological age. F-ratios for self-rated Tanner stages and age groups were used to compare unadjusted and adjusted hormonal changes in growing young adolescents. Correlations of paired serum and urinary hormonal concentration of unadjusted and creatinine and specific gravity-adjusted were also compared. Fasting first morning void hormone concentrations correlated well and were unbiased between unadjusted or adjusted by either creatinine or specific gravity. Urine creatinine concentration increases with Tanner stages, age and male gender whereas urine specific gravity was not influenced by Tanner stage, age or gender. Adjustment by creatinine or specific gravity of urinary luteinizing hormone, estradiol, testosterone, dihydrotestosterone and dehydroepiandrosterone concentrations did not improve correlation with paired serum concentrations. Urine steroid and luteinizing hormone concentrations in first morning void samples of adolescents are not significantly influenced by hydration status and may not require adjustments; however, if desired, both creatinine and specific gravity adjustments are equally suitable. © The Author(s) 2015.

  12. Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay.

    Science.gov (United States)

    Kemperman, F A; Silberbusch, J; Slaats, E H; van Zanten, A P; Weber, J A; Krediet, R T; Arisz, L

    1999-05-01

    Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this study was to compare cimetidine-aided GFR estimations using various creatinine assays. In 30 outpatients with NIDDM GFR was measured as the urinary clearance of continuously infused [125I]iothalamate. Plasma creatinine concentration was analysed after oral cimetidine with an alkaline picrate (AP) method, with an enzymatic (PAP) assay and with HPLC. GFR estimations were calculated with the Cockcroft Gault formula (CG). AP creatinine concentrations were significantly higher than PAP or HPLC values. GFR estimations by AP (CG(AP) 66 +/- 19 ml/min/1.73 m2, mean SD) were significantly lower than GFR (89 +/- 30), whereas CG(PAP) (85 +/- 30) and CG(HPLC) (84 +/- 34 ml/min/1.73 m2) were not. Bland and Altman analysis showed a difference between CG(AP) and GFR of -22.4 +/- 17.7 ml/min/1.73 m2; this difference becomes larger when the GFR increases. The difference between CG and GFR was only -3.8 +/- 14.8 ml/min/1.73 m2 for PAP and -4.4 +/- 17.5 ml/min/1.73 m2 for HPLC, without any systematic difference. A good assessment of the GFR from plasma creatinine after cimetidine administration is possible when creatinine is measured with an enzymatic assay or with the less convenient HPLC method. The more widespread and cheaper alkaline picrate assay is not suitable for GFR-estimation.

  13. Cystatin C levels in healthy kidney donors and its correlation with GFR by creatinine clearance

    International Nuclear Information System (INIS)

    Ayub, S.; Khan, S.; Zafar, M.N.

    2014-01-01

    Objective: To determine Serum Cystatin C (S.CysC) levels in healthy potential kidney donors and its correlation with Serum Creatinine (S.Cr), Glomerular filtration rate (GFR) by 24 hour urinary Creatinine clearance (CCL) and GFR by formulae of Cockcroft Gault (CCG) and Modification of diet in Renal Disease (MDRD). Methods: A Cross sectional study was conducted at Sindh Institute of Urology and Transplantation (SIUT), Karachi, between June and December 2012. One hundred and three potential healthy kidney donors were enrolled in the study to measure their S.CysC and correlate it with S.Cr, CCL and GFR by CCG and MDRD. Statistical analysis was done by SPSS 17. Results: The mean age of the healthy kidney donors was 32.19+8.27 years with a M:F ratio of 1.86:1. The mean Serum Creatinine (S.Cr) was 0.86+0.18 mg/dl and mean S.CysC was 0.88+0.12 mg/dl. S.CysC showed significant correlation with S.Cr (r = 0.78, p<0.001), CCL (r = 0.67, p<0.001), GFR CCG (r = 0.54, p<0.001) and GFR MDRD (r = 0.67, p<0.001). Correlation of S.CysC was better than S.Cr for CCL, S.Cr (0.60) vs S.CysC (0.67) and GFR CCG, S.Cr (0.41) vs S.CysC (0.54). Correlation was comparable for MDRD, S.Cr (0.67) vs S.Cys (0.67). Conclusion: S.CysC is better marker of kidney function in potential healthy kidney donors. It is a reliable, convenient and economical marker that can be used especially in routine clinical practice. (author)

  14. Creatinine urine test

    Science.gov (United States)

    Urine creatinine test ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ... done to see how well your kidneys work. Creatinine is removed by the body entirely by the ...

  15. Clinical value of the joint measurement of serum concentrations of type IV collagen and laminin in patients with diabetic nephropathy

    International Nuclear Information System (INIS)

    Wang Lu; Wang Ping; Li Yongpei

    2004-01-01

    Objective: To study clinical value of the joint measurement of serum concentrations of type IV collagen (IV C) and laminin (LN) in patients with diabetic nephropathy (DN) by radioimmunoassay (RIA). Methods: Serum concentrations of IV C, LN were measured by RIA in 35 diabetic patients with normalbuminuria (group A), 28 cases of microalbuminuria (group B), 15 cases of macroalbuminuria (group C) and 30 normal subjects as control . Results: The serum concentrations of IV C, LN in total 78 diabetic patients [(97.6 ± 19.2), (132.4 ± 31.5) μg/L] were higher than that of the controls [(77.4 ± 8.2), (101.5 ± 17.6) μg/L, P<0.05], especially in group B and C, it was remarkably higher compared with the controls (P<0.05, P<0.01). There was significant positive correlation of serum IV C, LN to diabetic duration and the levels of blood urea nitrogen (BUN), creatinine (Cr), urinary albumin excretion rate (UAER). Conclusions: The results suggest that the joint measurement of serum levels of IV C, LN and UAER in DN patients might better evaluate the development process of DN, and be of help for early diagnosis and treatment of DN. Serum levels of IV C, LN and UAER in DN patients may become the reliable clinical markers for assessing the severity and predicting the prognosis of DN

  16. GFR Prediction From Cystatin C and Creatinine in Children

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Boegsted, Martin

    2012-01-01

    area, and SCr is serum creatinine level. The accuracy and precision of these models were compared with 7 previously published prediction models using random subsampling cross-validation. Local constants and coefficients were calculated for all models. Root mean square error, R2, and percentage...... are still not sufficiently accurate to replace exogenous markers when GFR must be determined with high accuracy....

  17. Association between serum interleukin-6 and serum 3,5,3'-triiodothyronine in nonthyroidal illness

    NARCIS (Netherlands)

    Boelen, A.; Platvoet-ter Schiphorst, M. C.; Wiersinga, W. M.

    1993-01-01

    Increased serum concentrations of FFA, bilirubin, and carboxyl-methyl-propyl-furanpropionic acid, accumulating in chronic renal failure in direct relationship with serum creatinine, have all been implicated in the pathogenesis of the low T3 syndrome during illness. Cytokines may also be involved in

  18. Performance of Chronic Kidney Disease Epidemiology Collaboration Creatinine-Cystatin C Equation for Estimating Kidney Function in Cirrhosis

    Science.gov (United States)

    Mindikoglu, Ayse L.; Dowling, Thomas C.; Weir, Matthew R.; Seliger, Stephen L.; Christenson, Robert H.; Magder, Laurence S.

    2013-01-01

    Conventional creatinine-based glomerular filtration rate (GFR) equations are insufficiently accurate for estimating GFR in cirrhosis. The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) recently proposed an equation to estimate GFR in subjects without cirrhosis using both serum creatinine and cystatin C levels. Performance of the new CKD-EPI creatinine-cystatin C equation (2012) was superior to previous creatinine- or cystatin C-based GFR equations. To evaluate the performance of the CKD-EPI creatinine-cystatin C equation in subjects with cirrhosis, we compared it to GFR measured by non-radiolabeled iothalamate plasma clearance (mGFR) in 72 subjects with cirrhosis. We compared the “bias”, “precision” and “accuracy” of the new CKD-EPI creatinine-cystatin C equation to that of 24-hour urinary creatinine clearance (CrCl), Cockcroft-Gault (CG) and previously reported creatinine- and/or cystatin C-based GFR-estimating equations. Accuracy of CKD-EPI creatinine-cystatin C equation as quantified by root mean squared error of difference scores [differences between mGFR and estimated GFR (eGFR) or between mGFR and CrCl, or between mGFR and CG equation for each subject] (RMSE=23.56) was significantly better than that of CrCl (37.69, P=0.001), CG (RMSE=36.12, P=0.002) and GFR-estimating equations based on cystatin C only. Its accuracy as quantified by percentage of eGFRs that differed by greater than 30% with respect to mGFR was significantly better compared to CrCl (P=0.024), CG (P=0.0001), 4-variable MDRD (P=0.027) and CKD-EPI creatinine 2009 (P=0.012) equations. However, for 23.61% of the subjects, GFR estimated by CKD-EPI creatinine-cystatin C equation differed from the mGFR by more than 30%. CONCLUSIONS The diagnostic performance of CKD-EPI creatinine-cystatin C equation (2012) in patients with cirrhosis was superior to conventional equations in clinical practice for estimating GFR. However, its diagnostic performance was substantially worse than

  19. Creatinine sensor based on a molecularly imprinted polymer-modified hanging mercury drop electrode.

    Science.gov (United States)

    Lakshmi, Dhana; Prasad, Bhim Bali; Sharma, Piyush Sindhu

    2006-09-15

    Molecularly imprinted polymers (MIP) have been elucidated to work as artificial receptors. In our present study, a MIP was applied as a molecular recognition element to a chemical sensor. We have constructed a creatinine sensor based on a MIP layer selective for creatinine and its differential pulse, cathodic stripping voltammetric detection (DPCSV) on a hanging mercury drop electrode (HMDE). The creatinine sensor was fabricated by the drop coating of dimethylformamide (DMF) solution of a creatinine-imprinted polymer onto the surface of HMDE. The modified-HMDE, preanodised in neutral medium at +0.4V versus Ag/AgCl for 120s, exhibited a marked enhancement in DPCSV current in comparison to the less anodised (creatinine was preconcentrated and instantaneously oxidised in MIP layer giving DPCSV response in the concentration range of 0.0025-84.0mugmL(-1) [detection limit (3sigma) 1.49ngmL(-1)]. The sensor was found to be highly selective for creatinine without any response of interferents viz., NaCl, urea, creatine, glucose, phenylalanine, tyrosine, histidine and cytosine. The non-imprinted polymer-modified electrode did not show linear response to creatinine. The imprinting factor as high as 9.4 implies that the imprinted polymer exclusively acts as a recognition element of creatinine sensor. The proposed procedure can be used to determine creatinine in human blood serum without any preliminary treatment of the sample in an accurate, rapid and simple way.

  20. Early serum creatinine changes and outcomes in patients admitted for acute heart failure: the cardio-renal syndrome revisited.

    Science.gov (United States)

    Núñez, Julio; Garcia, Sergio; Núñez, Eduardo; Bonanad, Clara; Bodí, Vicent; Miñana, Gema; Santas, Enrique; Escribano, David; Bayes-Genis, Antonio; Pascual-Figal, Domingo; Chorro, Francisco J; Sanchis, Juan

    2017-08-01

    The changes in renal function that occurred in patients with acute decompensated heart failure (ADHF) are prevalent, and have multifactorial etiology and dissimilar prognosis. To what extent the prognostic role of such changes may vary according to the presence of renal insufficiency at admission is not clear. Accordingly, we sought to determine whether early creatinine changes (ΔCr) (admission to 48-72 hours) had an effect on 1-year mortality relative to the presence of renal insufficiency at admission. We included 705 consecutive patients admitted with the diagnosis of ADHF. Admission renal insufficiency was defined as serum creatinine ≥1.4mg/dl (A-RI cr ) or estimated glomerular filtration rate renal insufficiency (24.7% and 42.8% for A-RIcr and A-RIGFR, respectively) had higher prevalence of extreme values in ΔCr in either direction (increasing/decreasing). At 1-year follow-up, 114 (16.2%) deaths were registered. The multivariable analysis showed a significant interaction between admission renal insufficiency and ΔCr ( p=0.004 and p=0.019 for A-RIcr and A-RIGFR, respectively). In the presence of renal insufficiency, the continuum of ΔCr followed a positive and almost linear relationship with mortality risk. Conversely, in patients without renal insufficiency, those changes adopted a 'J-shape' trajectory with increased mortality at both ends of the curve distribution. In patients with ADHF the effect of ΔCr on 1-year mortality varied according to its magnitude and the presence of admission renal insufficiency. There was a graded-association with mortality when renal insufficiency was present on admission.

  1. The relationship of nitric oxide synthesis capacity, oxidative stress, and albumin-to-creatinine ratio in black and white men: the SABPA study.

    Science.gov (United States)

    Mels, Catharina M C; Huisman, Hugo W; Smith, Wayne; Schutte, Rudolph; Schwedhelm, Edzard; Atzler, Dorothee; Böger, Rainer H; Ware, Lisa J; Schutte, Aletta E

    2016-02-01

    Inadequate substrate availability and increased nitric oxide synthase inhibitor levels attenuate nitric oxide (NO) synthesis, whereas increased vascular oxidative stress may lead to inactivation of NO. We compared markers of NO synthesis capacity and oxidative stress in a bi-ethnic male population. Inter-relationships of ambulatory blood pressure and urinary albumin-to-creatinine ratio with NO synthesis capacity and oxidative stress markers were investigated. NO synthesis capacity markers (L-arginine, asymmetric dimethylarginine (ADMA), and symmetric dimethylarginine (SDMA)) and oxidative stress markers (serum peroxides, total glutathione, glutathione peroxidase (GPx), glutathione reductase (GR), superoxide dismutase (SOD), and catalase) were measured. Black men displayed higher blood pressure and albumin-to-creatinine ratio (all p creatinine ratio. In white men, albumin-to-creatinine ratio was positively associated with ADMA (R (2) = 0.18; β = 0.39; p creatinine ratio displayed a favorable NO synthesis capacity. This may be counteracted by increased inactivation of NO, although it was not linked to vascular or renal phenotypes. In white men, reduced NO synthesis capacity may lower NO bio-availability, thereby influencing the albumin-to-creatinine ratio.

  2. The influence of a cooked meat meal on creatinine plasma concentration and creatinine clearance.

    OpenAIRE

    Mayersohn, M; Conrad, K A; Achari, R

    1983-01-01

    1 The influence of a meal containing cooked meat (225 g) on creatinine plasma concentration, creatinine urinary excretion and creatinine clearance was determined in six healthy male subjects. 2 The meat meal produced an average 52% increase in creatinine plasma concentration within 1.5 to 3.5 h after ingestion. The 24 h area under the creatinine plasma concentration-time curve increased by about 19%. Urinary creatinine excretion during 24 h increased by an average of 13%. Creatinine clearance...

  3. The marker of cobalamin deficiency, plasma methylmalonic acid, correlates to plasma creatinine

    DEFF Research Database (Denmark)

    Hvas, A M; Juul, S; Gerdes, Lars Ulrik

    2000-01-01

    OBJECTIVE: To examine the relationship between the two diagnostic tests, plasma methylmalonic acid and plasma cobalamins, and their association with plasma creatinine, age and sex. DESIGN: Cross-sectional study of simultaneous laboratory measurements. SETTING: County of Aarhus, Denmark. SUBJECTS......: Records on 1689 patients who had their first plasma methylmalonic acid measurement during 1995 and 1996, and who had a simultaneous measurement of plasma cobalamins. Plasma creatinine values measured within a week of measurements of plasma methylmalonic acid and plasma cobalamins were available for 1255...... of the patients. MAIN OUTCOME MEASURES: Predictors of variation in plasma methylmalonic acid; plasma cobalamins, plasma creatinine, age and sex. RESULTS: Plasma methylmalonic acid was positively correlated with plasma creatinine, even for plasma creatinine within the normal range. These associations remained...

  4. Pre-procedural peripheral endothelial function is associated with increased serum creatinine following percutaneous coronary procedure in stable patients with a preserved estimated glomerular filtration rate.

    Science.gov (United States)

    Sumida, Hitoshi; Matsuzawa, Yasushi; Sugiyama, Seigo; Sugamura, Koichi; Nozaki, Toshimitsu; Akiyama, Eiichi; Ohba, Keisuke; Konishi, Masaaki; Matsubara, Junichi; Fujisue, Koichiro; Maeda, Hirofumi; Kurokawa, Hirofumi; Iwashita, Satomi; Ogawa, Hisao; Tsujita, Kenichi

    2017-11-01

    Worsening renal function, indicated by increased serum creatinine (SCr), is a common complication of percutaneous coronary procedures. Risk factors for increased SCr overlap with coronary risk factors involved in endothelial dysfunction. We hypothesized that endothelial dysfunction, measured using the reactive hyperemia peripheral arterial tonometry index (RHI), can predict periprocedure-increased SCr. RHI was assessed before elective coronary procedures in 316 consecutive stable patients with a preserved estimated glomerular filtration rate (eGFR, >60mL/min/1.73m 2 ). SCr was measured before and 2 days after procedures. There was no significant correlation between natural logarithmic transformations of RHI (Ln-RHI) and basal Ln-eGFR. Periprocedure increase in SCr was observed in 148 (47%) patients. The increased SCr group had significantly lower Ln-RHI [0.48 (0.36, 0.62) vs. 0.59 (0.49, 0.76), pfunction by RHI is an effective strategy to assess the patient's risk conditions for worsening renal function after percutaneous coronary procedures. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  5. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies

    OpenAIRE

    Reischies, Frederike M. J.; Raggam, Reinhard B.; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-01-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with...

  6. Risk Stratification of Acute Kidney Injury Using the Blood Urea Nitrogen/Creatinine Ratio in Patients With Acute Decompensated Heart Failure.

    Science.gov (United States)

    Takaya, Yoichi; Yoshihara, Fumiki; Yokoyama, Hiroyuki; Kanzaki, Hideaki; Kitakaze, Masafumi; Goto, Yoichi; Anzai, Toshihisa; Yasuda, Satoshi; Ogawa, Hisao; Kawano, Yuhei

    2015-01-01

    Risk stratification of acute kidney injury (AKI) is important for acute decompensated heart failure (ADHF). The aim of this study was to determine whether clinical markers, such as the blood urea nitrogen/creatinine ratio (BUN/Cr) or BUN or creatinine values alone, stratify the risk of AKI for mortality. In all, 371 consecutive ADHF patients were enrolled in the study. AKI was defined as serum creatinine ≥0.3 mg/dl or a 1.5-fold increase in serum creatinine levels within 48 h. During ADHF therapy, AKI occurred in 99 patients; 55 patients died during the 12-month follow-up period. Grouping patients according to AKI and a median BUN/Cr at admission of 22.1 (non-AKI+low BUN/Cr, non-AKI+high BUN/Cr, AKI+low BUN/Cr, and AKI+high BUN/Cr groups) revealed higher mortality in the AKI+high BUN/Cr group (log-rank test, Phigh BUN/Cr and mortality, whereas the association with AKI+low BUN/Cr did not reach statistical significance. When patients were grouped according to AKI and median BUN or creatinine values at admission, AKI was associated with mortality, regardless of BUN or creatinine. The combination of AKI and elevated BUN/Cr, but not BUN or creatinine individually, is linked with an increased risk of mortality in ADHF patients, suggesting that the BUN/Cr is useful for risk stratification of AKI.

  7. Effect of Oestrogen on Altering the Serum and Urinary Levels of Calcium, Phosphate and Magnesium in Hysterectomised Women Compared to Natural Menopausal South Indian Women: A Case Control Study.

    Science.gov (United States)

    Sonu, Yeldose; Avinash, S S; Sreekantha; Arun Kumar, K; Malathi, M; Shivashankara, A R

    2016-07-01

    Given the paucity of studies conducted to know the effect of suddenness and earlier onset of endocrinological changes associated with hysterectomy, on the serum and urinary levels of calcium, magnesium and phosphate the present study was conducted to compare the levels of calcium, magnesium and phosphate in serum and urine of hysterectomised and natural menopausal south Indian women. This is a cross-sectional observational study. The study included three groups of 30 healthy premenopausal, 30 early surgical menopausal and 30 natural post menopausal women. Women suffering from any endocrine disease were excluded. Analysis was performed in serum and urine sample. The levels of calcium, magnesium and phosphate in serum and calcium/creatinine, magnesium/creatinine and phosphate/creatinine ratio were estimated in urine by spectrophotometric method. Hysterectomised women (serum calcium: 8.7 ± 0.09 mg/dl; urine calcium/creatinine: 0.16 ± 0.02) have significantly low serum calcium (p women (serum magnesium: 2.1 ± 0.03; serum phosphate: 4.4 ± 0.16; urinary calcium/creatinine: 0.17 ± 0.02; urinary magnesium/creatinine: 0.09 ± 0.01) have significantly high serum magnesium (p = 0.016), serum phosphate (p = 0.043) and high urinary calcium/creatinine (p = 0.002), magnesium/creatinine ratio (p = 0.025) compared to healthy pre menopausal women. Post menopausal women (serum calcium: 9.1 ± 0.08) have significantly high serum calcium and phosphate compared to hysterectomised women (serum phosphate: 3.93 ± 0.11). Hysterectomised women have significantly low serum calcium, oestrogen and high urinary calcium/creatinine ratio compared to healthy premenopausal women and low serum calcium and low serum phosphate compared to natural postmenopausal women. Natural postmenopausal women had low serum oestrogen and high serum magnesium, serum phosphate, urinary calcium creatinine ratio and urinary magnesium creatinine ratio compared to healthy premenopausal

  8. Creatinine Versus Cystatin C: Differing Estimates of Renal Function in Hospitalized Veterans Receiving Anticoagulants.

    Science.gov (United States)

    Wang, Christina Hao; Rubinsky, Anna D; Minichiello, Tracy; Shlipak, Michael G; Price, Erika Leemann

    2018-05-31

    Current practice in anticoagulation dosing relies on kidney function estimated by serum creatinine using the Cockcroft-Gault equation. However, creatinine can be unreliable in patients with low or high muscle mass. Cystatin C provides an alternative estimation of glomerular filtration rate (eGFR) that is independent of muscle. We compared cystatin C-based eGFR (eGFR cys ) with multiple creatinine-based estimates of kidney function in hospitalized patients receiving anticoagulants, to assess for discordant results that could impact medication dosing. Retrospective chart review of hospitalized patients over 1 year who received non-vitamin K antagonist anticoagulation, and who had same-day measurements of cystatin C and creatinine. Seventy-five inpatient veterans (median age 68) at the San Francisco VA Medical Center (SFVAMC). We compared the median difference between eGFR by the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) study equation using cystatin C (eGFR cys ) and eGFRs using three creatinine-based equations: CKD-EPI (eGFR EPI ), Modified Diet in Renal Disease (eGFR MDRD ), and Cockcroft-Gault (eGFR CG ). We categorized patients into standard KDIGO kidney stages and into drug-dosing categories based on each creatinine equation and calculated proportions of patients reclassified across these categories based on cystatin C. Cystatin C predicted overall lower eGFR compared to creatinine-based equations, with a median difference of - 7.1 (IQR - 17.2, 2.6) mL/min/1.73 m 2 versus eGFR EPI , - 21.2 (IQR - 43.7, - 8.1) mL/min/1.73 m 2 versus eGFR MDRD , and - 25.9 (IQR - 46.8, - 8.7) mL/min/1.73 m 2 versus eGFR CG . Thirty-one to 52% of patients were reclassified into lower drug-dosing categories using cystatin C compared to creatinine-based estimates. We found substantial discordance in eGFR comparing cystatin C with creatinine in this group of anticoagulated inpatients. Our sample size was limited and included few women. Further

  9. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  10. Detection and prognostic impact of renal dysfunction in patients with chronic heart failure and normal serum creatinine.

    Science.gov (United States)

    Scrutinio, Domenico; Passantino, Andrea; Lagioia, Rocco; Santoro, Daniela; Cacciapaglia, Erasmo

    2011-03-03

    Accurate identification of renal dysfunction (RD) is crucial to risk stratification in chronic heart failure (CHF). Patients with CHF are at special risk of having RD despite normal serum creatinine (SCr), owing to a decreased Cr generation. At low levels of SCr, the equations estimating renal function are less accurate. This study was aimed to assess and compare the prognostic value of formulas estimating renal function in CHF patients with normal SCr. We studied 462 patients with systolic CHF and normal SCr. Creatinine clearance was estimated by the Cockcroft-Gault (eCrCl) and glomerular filtration rate by the 4-variable MDRD equation (eGFR); eCrCl normalized for body-surface area (eCrCl(BSA)) was calculated. The primary outcome was all-cause mortality at 2 years. Seventy five patients died. At multivariate Cox regression analysis, only eCrCl(BSA) was significantly associated with mortality (p = 0.006); eGFR (p = 0.24), eCrCl (p = 0.09) and BUN (p = 0.14) were not statistically significant predictors. The patients in the lowest eCrCl(BSA) quartile had an adjusted 2.1-fold (CI: 1.06-4.1) increased risk of mortality, compared with those in the referent quartile. Two-year survival was 70.4% in the lowest eCrCl(BSA) quartile and 89.7% in the referent quartile. Other independent predictors of mortality were ischemic etiology (RR: 2.16 [CI: 1.3-3.5], p = 0.0017), NYHA III/IV class (RR: 2.45 [CI: 1.51-3.97], p = 0.0003), LVEF high-risk subgroup and can more accurately be identified by the CG formula corrected for BSA than the MDRD. Copyright © 2009 Elsevier B.V. All rights reserved.

  11. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Creatinine Clearance Is Not Equal to Glomerular Filtration Rate and Cockcroft-Gault Equation Is Not Equal to CKD-EPI Collaboration Equation.

    Science.gov (United States)

    Fernandez-Prado, Raul; Castillo-Rodriguez, Esmeralda; Velez-Arribas, Fernando Javier; Gracia-Iguacel, Carolina; Ortiz, Alberto

    2016-12-01

    Direct oral anticoagulants (DOACs) may require dose reduction or avoidance when glomerular filtration rate is low. However, glomerular filtration rate is not usually measured in routine clinical practice. Rather, equations that incorporate different variables use serum creatinine to estimate either creatinine clearance in mL/min or glomerular filtration rate in mL/min/1.73 m 2 . The Cockcroft-Gault equation estimates creatinine clearance and incorporates weight into the equation. By contrast, the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations estimate glomerular filtration rate and incorporate ethnicity but not weight. As a result, an individual patient may have very different renal function estimates, depending on the equation used. We now highlight these differences and discuss the impact on routine clinical care for anticoagulation to prevent embolization in atrial fibrillation. Pivotal DOAC clinical trials used creatinine clearance as a criterion for patient enrollment, and dose adjustment and Federal Drug Administration recommendations are based on creatinine clearance. However, clinical biochemistry laboratories provide CKD-EPI glomerular filtration rate estimations, resulting in discrepancies between clinical trial and routine use of the drugs. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Back-calculating baseline creatinine overestimates prevalence of acute kidney injury with poor sensitivity.

    Science.gov (United States)

    Kork, F; Balzer, F; Krannich, A; Bernardi, M H; Eltzschig, H K; Jankowski, J; Spies, C

    2017-03-01

    Acute kidney injury (AKI) is diagnosed by a 50% increase in creatinine. For patients without a baseline creatinine measurement, guidelines suggest estimating baseline creatinine by back-calculation. The aim of this study was to evaluate different glomerular filtration rate (GFR) equations and different GFR assumptions for back-calculating baseline creatinine as well as the effect on the diagnosis of AKI. The Modification of Diet in Renal Disease, the Chronic Kidney Disease Epidemiology (CKD-EPI) and the Mayo quadratic (MQ) equation were evaluated to estimate baseline creatinine, each under the assumption of either a fixed GFR of 75 mL min -1  1.73 m -2 or an age-adjusted GFR. Estimated baseline creatinine, diagnoses and severity stages of AKI based on estimated baseline creatinine were compared to measured baseline creatinine and corresponding diagnoses and severity stages of AKI. The data of 34 690 surgical patients were analysed. Estimating baseline creatinine overestimated baseline creatinine. Diagnosing AKI based on estimated baseline creatinine had only substantial agreement with AKI diagnoses based on measured baseline creatinine [Cohen's κ ranging from 0.66 (95% CI 0.65-0.68) to 0.77 (95% CI 0.76-0.79)] and overestimated AKI prevalence with fair sensitivity [ranging from 74.3% (95% CI 72.3-76.2) to 90.1% (95% CI 88.6-92.1)]. Staging AKI severity based on estimated baseline creatinine had moderate agreement with AKI severity based on measured baseline creatinine [Cohen's κ ranging from 0.43 (95% CI 0.42-0.44) to 0.53 (95% CI 0.51-0.55)]. Diagnosing AKI and staging AKI severity on the basis of estimated baseline creatinine in surgical patients is not feasible. Patients at risk for post-operative AKI should have a pre-operative creatinine measurement to adequately assess post-operative AKI. © 2016 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  14. Decline in 51Cr-labelled EDTA measured glomerular filtration rate following lung transplantation

    DEFF Research Database (Denmark)

    Hornum, Mads; Burton, Christopher M; Iversen, Martin

    2007-01-01

    -labelled EDTA clearance (mGFR) and the Cockcroft-Gault calculated clearance (cGFR). Trough cyclosporine levels (C0) and demographic and transplant information were also included in the analysis. RESULTS: A total of 66959 C0 and serum creatinine and 1945 mGFR measurements pertaining to 383 patients were included...... in the analysis. Pre-transplant mGFR was significantly lower with respect to recipient age over 60 years; and patients with a referral diagnosis of pulmonary hypertension had a lower mGFR and higher baseline serum creatinine levels than patients with emphysematous disease (P ... correlations between log(10) mean interval serum creatinine and log(2) mGFR at all time points pre- and post-transplantation (P

  15. High-Density Lipoprotein Cholesterol, Blood Urea Nitrogen, and Serum Creatinine Can Predict Severe Acute Pancreatitis.

    Science.gov (United States)

    Hong, Wandong; Lin, Suhan; Zippi, Maddalena; Geng, Wujun; Stock, Simon; Zimmer, Vincent; Xu, Chunfang; Zhou, Mengtao

    2017-01-01

    Early prediction of disease severity of acute pancreatitis (AP) would be helpful for triaging patients to the appropriate level of care and intervention. The aim of the study was to develop a model able to predict Severe Acute Pancreatitis (SAP). A total of 647 patients with AP were enrolled. The demographic data, hematocrit, High-Density Lipoprotein Cholesterol (HDL-C) determinant at time of admission, Blood Urea Nitrogen (BUN), and serum creatinine (Scr) determinant at time of admission and 24 hrs after hospitalization were collected and analyzed statistically. Multivariate logistic regression indicated that HDL-C at admission and BUN and Scr at 24 hours (hrs) were independently associated with SAP. A logistic regression function (LR model) was developed to predict SAP as follows: -2.25-0.06 HDL-C (mg/dl) at admission + 0.06 BUN (mg/dl) at 24 hours + 0.66 Scr (mg/dl) at 24 hours. The optimism-corrected c-index for LR model was 0.832 after bootstrap validation. The area under the receiver operating characteristic curve for LR model for the prediction of SAP was 0.84. The LR model consists of HDL-C at admission and BUN and Scr at 24 hours, representing an additional tool to stratify patients at risk of SAP.

  16. Serum Uric Acid Levels and Uric Acid/Creatinine Ratios in Stable Chronic Obstructive Pulmonary Disease (COPD) Patients: Are These Parameters Efficient Predictors of Patients at Risk for Exacerbation and/or Severity of Disease?

    Science.gov (United States)

    Durmus Kocak, Nagihan; Sasak, Gulsah; Aka Akturk, Ulku; Akgun, Metin; Boga, Sibel; Sengul, Aysun; Gungor, Sinem; Arinc, Sibel

    2016-11-03

    BACKGROUND Serum uric acid (sUA) levels were previously found to be correlated with hypoxic states. We aimed to determine the levels of sUA and sUA/creatinine ratios in stable COPD patients and to evaluate whether sUA level and sUA/creatinine ratio can be used as predictors of exacerbation risk and disease severity. MATERIAL AND METHODS This cross-sectional study included stable COPD patients and healthy controls. The sUA levels and sUA/creatinine ratios in each group were evaluated and their correlations with the study parameters were investigated. ROC analyses for exacerbation risk and disease severity were reported. RESULTS The study included 110 stable COPD patients and 52 healthy controls. The mean sUA levels and sUA/creatinine ratios were significantly higher in patients with COPD compared to healthy controls. The most common comorbidities in COPD patients were hypertension, diabetes, and coronary artery disease. While sUA levels were significantly higher in patients with hypertension (p=0.002) and malignancy (p=0.033), sUA/creatinine ratios was higher in patients with malignancy (p=0.004). The ROC analyses indicated that sUA/creatinine ratios can be more useful than sUA levels in predicting exacerbation risk (AUC, 0.586 vs. 0.426) and disease severity (AUC, 0.560 vs. 0.475) especially at higher cut-off values, but with low specificity. CONCLUSIONS Our study suggested that sUA levels and sUA/creatinine ratios increased in patients with stable COPD, especially among patients with certain comorbidities compared to healthy controls. At higher cut-off values, sUA levels and especially sUA/creatinine ratios, might be useful in predicting COPD exacerbation risk and disease severity. Also, their association with comorbidities, especially with malignancy and hypertension, may benefit from further investigation.

  17. Back to Basics: Is There a Good Reason to Not Systematically Measure Urine Creatinine in Acute Kidney Injury Monitoring?

    Science.gov (United States)

    Maciel, Alexandre Toledo

    2016-01-01

    Regardless of the recent advancements in the understanding of the pathophysiology of acute kidney injury (AKI), its diagnosis remains fundamentally dependent on the serum creatinine (sCr) level and urine output (UO), both of which are considered late markers of AKI, offering only a vague idea of the actual creatinine clearance (CrCl). Although not ideal, CrCl is still the most common alternative of the glomerular filtration rate (GFR) in clinical practice. It is generally accepted that early diagnosis of AKI must reveal kidney impairment before sCr increases. Much effort has been made to find tubular and glomerular markers of injury which increase (in blood and/or in urine) before the 'official' diagnosis of AKI. Most of these markers are expensive and not widely available, especially in developing countries. Urine creatinine (CrU), the major link between sCr and UO, has been systematically ignored and clinicians are usually unaware of its value. The reasons for this are unclear, but it may be related to the lack of a reference range, dependence of its concentration value on the urine flow (which in turn is only adequately assessed with an indwelling urinary catheter) and the clinical unavailability of its counterbalance part - creatinine production. Changes in urine tend to precede changes in blood in the course of AKI development and recovery. Hence, it is important to bear in mind that changes in sCr signal renal dysfunction with a significant delay. The search for a more dynamic, 'real-time' but pragmatic assessment of renal function, especially in patients at risk of abrupt decrease in GFR is certainly one of the most relevant focus of research in the field of AKI monitoring. Systematic CrU assessment may be highly relevant in this case. © 2016 S. Karger AG, Basel.

  18. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    Science.gov (United States)

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  19. Study of serum levels of calcium, phosphorus and alkaline phosphatase in chronic kidney disease

    Directory of Open Access Journals (Sweden)

    R. Freethi

    2016-03-01

    Full Text Available Chronic kidney disease (CKD is a worldwide public health problem, with increasing prevalence and lethal adverse outcomes like progressive loss of kidney function, cardiovascular disease and premature death. Disturbances in mineral metabolism and bone disease are common complications of CKD and an important cause of morbidity and decreased quality of life in patients with CKD. Patients with renal failure have an increased risk of cardiovascular mortality that may be due in part to vascular calcification. To measure serum levels of calcium, phosphorus and alkaline phosphatase in patients in various stages of CKD and to correlate the same with creatinine and estimated Glomerular Filtration Rate (eGFRvalues. This is a cross sectional study done at Thanjavur Medical College Hospital. 60 CKD patients and 50 healthy controls were enrolled in this study. Serum levels of creatinine, calcium, phosphorus and alkaline phosphatase were measured and eGFR values correlated with the serum creatinine. The mean values of creatinine (4.9 ± 2.23 mg/dl, cal cium (9.8 ± 0.456 mg/dl , phosphorus (4.19 ± 0.404 mg/dl and alkaline phosphatase (94.01 ± 15.10 U/L in the stu dy group are significantly higher than the control group in which the mean levels are 0.89 ± 0.102 mg/dl, 10.17 ± 0.37 mg/dl, 4.02 ± 0.16 mg/dl and 25.16 ± 4.65U/ L respectively. We have found that there is a significant difference in the above said parameters among patients in different stages of CKD (stage 3-5 indicating the progression of mineral bone disease with advancing stage of CKD.

  20. Significance of Serum Leptin Assessment in Chronic Renal Patients on Dialysis

    International Nuclear Information System (INIS)

    Salem, E.S; Tawfik, M.S; ELaseily, E.S.

    2013-01-01

    The number of patients suffering from renal failure indicating dialysis has been increasing worldwide. Leptin hormone plays an important role in the development of malnutrition in these patients. Bone produces different hormones, such as osteocalcin (OC), which influences energy expenditure in humans. Disturbances in mineral metabolism and bone disease are common complications of chronic kidney disease (CKD). There are increasing evidences suggesting that these disorders in mineral and bone metabolism are associated with increased risk of cardiovascular calcification, morbidity, and mortality, especially among those who undergo maintenance renal dialysis. The present study was carried out to evaluate the importance of serum leptin assessment in renal dialysis patients. Serum leptin level was estimated by radioimmunoassay (RIA) using recombinant human leptin (Leptin- Human Ria-CT). Immunoradiometric assay kit (host IRMA) was used for in-vitro quantitative measurement of human intact OC. Serum creatinine level was determined by colorimetric method. This study included 60 patients (twenty suffering from CKD, thirty on dialysis and ten healthy controls). Serum leptin, OC and creatinine were found to be higher in patients of both groups compared to that of controls. Maximum increase was observed in patients on dialysis. From these results it is possible to conclude that, although patients with chronic renal disease exhibited significant increase in serum leptin, yet sudden additional increase can be related to serious pathology that can end in renal failure. The present study also highlighted the importance of OC as a marker of disturbed mineral-bone metabolism in chronic kidney disease (CKD) patients and those receiving dialysis that could lead to the atherosclerosis, extravascular calcification, morbidity and mortality. KeywoRdSLeptin, osteocalcin, Radioimmunoassay (RIA), Chronic kidney disease, Renal dialysis, Creatinine.

  1. Serum cystatin C and urinary neutrophil gelatinase-associated lipocalin in pediatric acute kidney injury; a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Neamatollah Ataei

    2017-10-01

    Full Text Available Background: Acute kidney injury (AKI refers to insults that lead to decreased kidney function within hours to weeks and can be associated with complications including chronic kidney failure, end-stage renal disease and even death. Although various biomarkers have been proposed to predict AKI in children, but no consensus has been reached on the best diagnostic method. Accordingly, the present study aimed to assess the correlation between urine NGAL levels and development of AKI in children and determine which one of the biomarkers of urine NGAL, serum Cystatin C and serum creatinine has a stronger association with AKI in the pediatric population. Methods: The present cross-sectional study was conducted on children younger than 14 years of age, hospitalized in the intensive care unit of Children’s Medical Centre in Tehran, Iran, during 2016. Urine NGAL, serum Cystatin C and serum creatinine levels of these subjects were measured on admission to the intensive care unit. The concentrations of serum Cystatin C and serum creatinine were measured again after 48 hours to determine the AKI status of the subjects. Data were analyzed to determine the association between GFR and the concentrations of evaluated biomarkers and to compare the levels of biomarkers between the four groups of no AKI, injury, failure, loss and end-stage. Results: A total of 104 children (59 boys and 45 girls, average age=28.0±3.5 months were included in this study. The mean level of uNGAL on admission in the No-AKI group (153.79±29.82 was significantly lower than the children in the injury (1225.0 ±275.0 and failure (756.56±147.79 groups (df:3, 100; F=10.74; p<0.0001. The mean concentration of Cystatin C on admission in the three groups of risk (0.94±0.30, injury (1.75±0.05 and failure (1.75±0.36 was also significantly higher than the No-AKI (0.27±0.04 (df:3, 100; F=19.21; p<0.0001. However, there was no significant correlation between the level of serum creatinine on

  2. Underestimation of urinary albumin to creatinine ratio in morbidly obese subjects due to high urinary creatinine excretion.

    Science.gov (United States)

    Guidone, Caterina; Gniuli, Donatella; Castagneto-Gissey, Lidia; Leccesi, Laura; Arrighi, Eugenio; Iaconelli, Amerigo; Mingrone, Geltrude

    2012-04-01

    Albuminuria, a chronic kidney and/or cardiovascular disease biomarker, is currently measured as albumin-to-creatinine ratio (ACR). We hypothesize that in severely obese individuals ACR might be abnormally low in spite of relatively high levels of urinary albumin due to increased creatininuria. One-hundred-eighty-four subjects were divided into tertiles based on their BMI. Fat-free mass (FFM) and fat-mass were assessed by DEXA; 24-h creatinine and albumin excretion, ACR, lipid profile and blood pressure were measured. Twenty-four-hour creatinine highly correlated (R = 0.75) with FFM. Since both creatininuria and albuminuria increased with the BMI, being the increase in creatininuria preponderant in subjects with BMI>35, their ratio (AC-ratio) did not change significantly from that of subjects in the lower BMI tertile. ACR only correlated with the systolic blood pressure, while both albuminuria and cretininuria correlated (P = 0.01) with the absolute 10-year CHD risk. In subjects with BMI>35, 100 mg of albumin excreted with urine increased the CHD risk of 2%. Albumin-to-creatinine ratio is underestimated in severely obese individuals as a consequence of the large creatininuria, which is proportional to the increased FFM. Therefore, at least in this population 24-h albuminuria should be more reliable than ACR. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  3. Body Composition Analysis Allows the Prediction of Urinary Creatinine Excretion and of Renal Function in Chronic Kidney Disease Patients.

    Science.gov (United States)

    Donadio, Carlo

    2017-05-28

    The aim of this study was to predict urinary creatinine excretion (UCr), creatinine clearance (CCr) and the glomerular filtration rate (GFR) from body composition analysis. Body cell mass (BCM) is the compartment which contains muscle mass, which is where creatinine is generated. BCM was measured with body impedance analysis in 165 chronic kidney disease (CKD) adult patients (72 women) with serum creatinine (SCr) 0.6-14.4 mg/dL. The GFR was measured ( 99m Tc-DTPA) and was predicted using the Modification of Diet in Renal Disease (MDRD) formula. The other examined parameters were SCr, 24-h UCr and measured 24-h CCr (mCCr). A strict linear correlation was found between 24-h UCr and BCM ( r = 0.772). Multiple linear regression (MR) indicated that UCr was positively correlated with BCM, body weight and male gender, and negatively correlated with age and SCr. UCr predicted using the MR equation (MR-UCr) was quite similar to 24-h UCr. CCr predicted from MR-UCr and SCr (MR-BCM-CCr) was very similar to mCCr with a high correlation ( r = 0.950), concordance and a low prediction error (8.9 mL/min/1.73 m²). From the relationship between the GFR and the BCM/SCr ratio, we predicted the GFR (BCM GFR). The BCM GFR was very similar to the GFR with a high correlation ( r = 0.906), concordance and a low prediction error (12.4 mL/min/1.73 m²). In CKD patients, UCr, CCr and the GFR can be predicted from body composition analysis.

  4. Correlation of Serum Cystatin C with Glomerular Filtration Rate in Patients Receiving Platinum-Based Chemotherapy

    Directory of Open Access Journals (Sweden)

    Ernesta Cavalcanti

    2016-01-01

    Full Text Available Objectives. Serum cystatin C seems to be an accurate marker of glomerular filtration rate (GFR compared to serum creatinine. The aim of this work was to explore the possibility of using serum cystatin C instead of serum creatinine to early predict renal failure in cancer patients who received platinum based chemotherapy. Design and Methods. Serum creatinine, serum cystatin C concentrations, and GFR were determined simultaneously in 52 cancer patients received carboplatin-based or cisplatin-based chemotherapy. Serum creatinine was assayed on Cobas C6000-Roche, serum cystatin C assay was performed on AIA 360-Tosoh, and GFR was determined in all patients, before the first cycle of chemotherapy and before the subsequent administrations. Results. In the overall series, for the prediction of a fall of GFR < 80 mL/min/1.73 m2, the AUC of the ROC curve for cystatin C was 0,667 and the best threshold was 1.135 mg/L (sensitivity 90.5%, specificity 61.1%. For a GFR fall < 60 mL/min/1.73 m2, the AUC of ROC curve for cystatin C was 74.3% and the best threshold was 1.415 mg/L (sensitivity 66.7%, specificity 73.2%. Conclusions. Baseline cystatin C values were not able to predict renal failure during subsequent treatment. In conclusion, serum cystatin C is not a reliable early marker to efficiently predict renal failure in patients receiving chemotherapy.

  5. Screening for renal insufficiency following ESUR (European Society of Urogenital Radiology) guidelines with on-site creatinine measurements in an outpatient setting

    International Nuclear Information System (INIS)

    Ledermann, H.P.; Mengiardi, B.; Schmid, A.; Froehlich, J.M.

    2010-01-01

    To report the results and implications for workflow following introduction of ESUR guidelines to screen for potential renal insufficiency (RI) in private practice with on-site creatinine measurements. A total of 1,766 consecutive outpatients scheduled for contrast-enhanced CT (CECT) completed the ESUR questionnaire enquiring about kidney disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout or use of nephrotoxic drugs. Patients with positive risk factors underwent on-site creatinine measurement and calculation of estimated glomerular filtration rate (eGFR). Attending radiologists adapted subsequent imaging depending on renal function and presence of risk factors. One or more ESUR risk factors were present in 796 (45.1%) patients, including hypertension (37.7%), nephrotoxic medication (21.3%), diabetes mellitus (8.0%), proteinuria (3.9%), renal disease (4.1%), gout (3.1%) and renal surgery (2.6%). Pre-procedural creatinine measurements revealed severe RI (eGFR -1 1.73 m -2 ) in 10 (1.3%) and moderate RI (eGFR 30-59 ml min -1 1.73 m -2 ) in 106 (13.8%). Imaging work-up was adapted in 132 (16.6%) as follows: reduction of contrast material dose (n = 85), CT without contrast (n = 40), changeover to MRI (n = 3) or scintigraphy (n = 4). Screening for RI following ESUR guidelines requires creatinine measurements in nearly half of outpatients scheduled for CECT and reveals moderate to severe renal impairment in 6.6%. (orig.)

  6. Measurements of purine derivatives and creatinine in spot urine samples of Chinese yellow cattle

    International Nuclear Information System (INIS)

    Xing, Z.; Xi, W.B.; Mo, F.; Liu, J.W.; Yang, Y.F.; Chen, X.B.

    2004-01-01

    An experiment was conducted using 18 Chinese Yellow Cattle located in 5 farms to study how supplementation of fermentable energy to low quality straw-based rations would improve rumen microbial protein synthesis. Within each farm, the animals were fed on five diets. Diets 1-2 were typical rice straw + by-products used by farmers and were low in fermentable energy content; Diets 3- 5 were more balanced, containing a higher content of fermentable energy. Purine derivatives (PD) and creatinine in spot urine samples were measured. The results showed that the PD to creatinine ratio was significantly higher with Diets 3-5 than with Diets 1-2. Organic matter digestibility and thus organic matter intake was also higher with Diets 3-5 compared to Diets 1-2. The results indicted that the efficiency of microbial protein synthesis could be improved by balancing the diet. (author)

  7. Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

    International Nuclear Information System (INIS)

    Zhang, Jie; Hisada, Aya; Yoshinaga, Jun; Shiraishi, Hiroaki; Shimodaira, Kazuhisa; Okai, Takashi; Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa

    2013-01-01

    Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

  8. Exposure to pyrethroids insecticides and serum levels of thyroid-related measures in pregnant women

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jie; Hisada, Aya [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Yoshinaga, Jun, E-mail: junyosh@k.u-tokyo.ac.jp [Department of Environmental Studies, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563 (Japan); Shiraishi, Hiroaki [National Institute for Environmental Studies, Onogawa 16-2, Tsukuba, Ibaraki 305-8563 (Japan); Shimodaira, Kazuhisa; Okai, Takashi [Department of Obstetrics and Gynecology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan); Noda, Yumiko; Shirakawa, Miyako; Kato, Nobumasa [Department of Psychiatry and Neurology, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa, Tokyo 142-8555 (Japan)

    2013-11-15

    Possible association between environmental exposure to pyrethroid insecticides and serum thyroid-related measures was explored in 231 pregnant women of 10–12 gestational weeks recruited at a university hospital in Tokyo during 2009–2011. Serum levels of free thyroxine (fT4), thyroid stimulating hormone (TSH) and thyroid biding globulin (TBG) and urinary pyrethroid insecticide metabolite (3-phenoxybenzoic acid, 3-PBA) were measured. Obstetrical information was obtained from medical records and dietary and lifestyle information was collected by self-administered questionnaire. Geometric mean concentration of creatinine-adjusted urinary 3-PBA was 0.363 (geometric standard deviation: 3.06) μg/g cre, which was consistent with the previously reported levels for non-exposed Japanese adult females. The range of serum fT4, TSH and TBG level was 0.83–3.41 ng/dL, 0.01–27.4 μIU/mL and 16.4–54.4 μg/mL, respectively. Multiple regression analysis was carried out by using either one of serum levels of thyroid-related measures as a dependent variable and urinary 3-PBA as well as other potential covariates (age, pre-pregnancy BMI, parity, urinary iodine, smoking and drinking status) as independent variables: 3-PBA was not found as a significant predictor of serum level of thyroid-related measures. Lack of association may be due to lower pyrethroid insecticide exposure level of the present subjects. Taking the ability of pyrethroid insecticides and their metabolite to bind to nuclear thyroid hormone (TH) receptor, as well as their ability of placental transfer, into consideration, it is warranted to investigate if pyrethroid pesticides do not have any effect on TH actions in fetus brain even though maternal circulating TH level is not affected. -- Highlights: • Pyrethroid exposure and thyroid hormone status was examined in pregnant women. • Urinary 3-phenoxybenzoic acid was used as a biomarker of exposure. • Iodine nutrition, age and other covariates were included

  9. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  10. Combining creatinine and volume kinetics identifies missed cases of acute kidney injury following cardiac arrest

    Science.gov (United States)

    2013-01-01

    Introduction Fluid resuscitation in the critically ill often results in a positive fluid balance, potentially diluting the serum creatinine concentration and delaying diagnosis of acute kidney injury (AKI). Methods Dilution during AKI was quantified by combining creatinine and volume kinetics to account for fluid type, and rates of fluid infusion and urine output. The model was refined using simulated patients receiving crystalloids or colloids under four glomerular filtration rate (GFR) change scenarios and then applied to a cohort of critically ill patients following cardiac arrest. Results The creatinine concentration decreased during six hours of fluid infusion at 1 litre-per-hour in simulated patients, irrespective of fluid type or extent of change in GFR (from 0% to 67% reduction). This delayed diagnosis of AKI by 2 to 9 hours. Crystalloids reduced creatinine concentration by 11 to 19% whereas colloids reduced concentration by 36 to 43%. The greatest reduction was at the end of the infusion period. Fluid dilution alone could not explain the rapid reduction of plasma creatinine concentration observed in 39 of 49 patients after cardiac arrest. Additional loss of creatinine production could account for those changes. AKI was suggested in six patients demonstrating little change in creatinine, since a 52 ± 13% reduction in GFR was required after accounting for fluid dilution and reduced creatinine production. Increased injury biomarkers within a few hours of cardiac arrest, including urinary cystatin C and plasma and urinary Neutrophil-Gelatinase-Associated-Lipocalin (biomarker-positive, creatinine-negative patients) also indicated AKI in these patients. Conclusions Creatinine and volume kinetics combined to quantify GFR loss, even in the absence of an increase in creatinine. The model improved disease severity estimation, and demonstrated that diagnostic delays due to dilution are minimally affected by fluid type. Creatinine sampling should be delayed at least

  11. Population-based estimation of renal function in healthy young Indian adults based on body mass index and sex correlating renal volume, serum creatinine, and cystatin C

    Directory of Open Access Journals (Sweden)

    Rajagopalan P

    2016-09-01

    Full Text Available Prashanth Rajagopalan,1 Georgi Abraham,2 Yuvaram NV Reddy,2 Ravivarman Lakshmanasami,1 ML Prakash,1 Yogesh NV Reddy2 1Department of General Medicine, Mahatma Gandhi Medical College and Research Institute, Puducherry, 2Department of Nephrology, Madras Medical Mission Hospital, Chennai, India Abstract: This population-based prospective study was undertaken in Mahatma Gandhi Medical College to estimate the renal function in young healthy Indian adults. A young healthy heterogeneous Indian cohort comprising 978 individuals, predominantly medical students, was assessed by a detailed questionnaire, and variables such as height, weight, body mass index (BMI, birth weight, and blood pressure were documented. Laboratory investigations included serum creatinine, serum cystatin C, blood sugar, urine protein, and imaging of the kidneys with ultrasound. The mean age of the cohort was 25±6 years, comprising 672 males and 306 females. The estimated glomerular filtration rates (eGFRs by the Cockcroft–Gault formula for BMI <18.5 kg/m2, 18.5–24.99 kg/m2, 25–29.99 kg/m2, and ≥30 kg/m2 were 71.29±10.45 mL/min, 86.38±13.46 mL/min, 98.88±15.29 mL/min, and 109.13±21.57 mL/min, respectively; the eGFRs using cystatin C for the four groups of BMI were 84.53±18.14 mL/min, 84.01±40.11 mL/min, 79.18±13.46 mL/min, and 77.30±10.90 mL/min, respectively. This study attempts to establish a normal range of serum creatinine and cystatin C values for the Indian population and shows that in young healthy Indian adults, eGFR and kidney volume vary by BMI and sex. Keywords: eGFR, birth weight, renal volume

  12. THE COMPARATIVE ANALYSIS OF RENAL FUNCTION IN LIVER DISEASES USING COCKCROFT-GAULT FORMULAE AND CREATININE CLEARANCE

    Directory of Open Access Journals (Sweden)

    Karem Ravi Teja

    2018-01-01

    Full Text Available BACKGROUND Kidney dysfunction in liver disease can be due to different aetiologies and can have diverse manifestations. Most of the abnormalities of kidney function in cirrhosis are of functional origin namely, sodium retention, impaired free water excretion and renal vasoconstriction with decrease in renal perfusion and glomerular filtration rate. Renal dysfunction in chronic liver disease usually follows a progressive course- the final phase being Hepatorenal Syndrome (HRS. MATERIALS AND METHODS This study included patients with chronic liver disease being treated as inpatients in the Department of General Medicine, Konaseema Institute of Medical Sciences, Amalapuram. Evidence for chronic liver disease being defined by a compatible clinical profile (signs of liver cell failure or reduced liver span along with biochemical (altered liver function tests, reversal of albuminglobulin ratio or sonographic evidence (altered echotexture of liver or tissue diagnosis (positive liver biopsy for cirrhosis. RESULTS Eighteen percent, i.e. 5 out of the 28 patients with creatinine clearance more than 60 mL/minute by Cockcroft-Gault formula were found to have creatinine clearance values less than 40 mL/minute when done by timed urine collection P value calculated was found to be less than 0.0001, which is statistically significant. CONCLUSION In chronic liver disease, serum creatinine alone is not a reliable marker to assess renal dysfunction. Calculating creatinine clearance by using Cockcroft-Gault formula overestimates renal function in cirrhotics. Creatinine clearance measured by timed urine collections should be done routinely to assess renal reserve in advanced liver disease. Alcoholism appears to have adverse effect on renal function when compared with other aetiologies of cirrhosis.

  13. Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine.

    Science.gov (United States)

    Fraselle, S; De Cremer, K; Coucke, W; Glorieux, G; Vanmassenhove, J; Schepers, E; Neirynck, N; Van Overmeire, I; Van Loco, J; Van Biesen, W; Vanholder, R

    2015-04-15

    Despite decades of creatinine measurement in biological fluids using a large variety of analytical methods, an accurate determination of this compound remains challenging. Especially with the novel trend to assess biomarkers on large sample sets preserved in biobanks, a simple and fast method that could cope with both a high sample throughput and a low volume of sample is still of interest. In answer to these challenges, a fast and accurate ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to measure creatinine in small volumes of human urine. In this method, urine samples are simply diluted with a basic mobile phase and injected directly under positive electrospray ionization (ESI) conditions, without further purification steps. The combination of an important diluting factor (10(4) times) due to the use of a very sensitive triple quadrupole mass spectrometer (XEVO TQ) and the addition of creatinine-d3 as internal standard completely eliminates matrix effects coming from the urine. The method was validated in-house in 2012 according to the EMA guideline on bioanalytical method validation using Certified Reference samples from the German External Quality Assessment Scheme (G-Equas) proficiency test. All obtained results for accuracy and recovery are within the authorized tolerance ranges defined by G-Equas. The method is linear between 0 and 5 g/L, with LOD and LOQ of 5 × 10(-3) g/L and 10(-2) g/L, respectively. The repeatability (CV(r) = 1.03-2.07%) and intra-laboratory reproducibility (CV(RW) = 1.97-2.40%) satisfy the EMA 2012 guideline. The validated method was firstly applied to perform the German G-Equas proficiency test rounds 51 and 53, in 2013 and 2014, respectively. The obtained results were again all within the accepted tolerance ranges and very close to the reference values defined by the organizers of the proficiency test scheme, demonstrating an excellent accuracy of the developed method. The

  14. Estimated Glomerular Filtration Rate Correlates Poorly with Four-Hour Creatinine Clearance in Critically Ill Patients with Acute Kidney Injury

    Directory of Open Access Journals (Sweden)

    Christopher J. Kirwan

    2013-01-01

    Full Text Available Introduction. RIFLE and AKIN provide a standardised classification of acute kidney injury (AKI, but their categorical rather than continuous nature restricts their use to a research tool. A more accurate real-time description of renal function in AKI is needed, and some published data suggest that equations based on serum creatinine that estimate glomerular filtration rate (eGFR can provide this. In addition, incorporating serum cystatin C concentration into estimates of GFR may improve their accuracy, but no eGFR equations are validated in critically ill patients with AKI. Aim. This study tests whether creatinine or cystatin-C-based eGFR equations, used in patients with CKD, offer an accurate representation of 4-hour creatinine clearance (4CrCl in critically ill patients with AKI. Methods. Fifty-one critically ill patients with AKI were recruited. Thirty-seven met inclusion criteria, and the performance of eGFR equations was compared to 4CrCl. Results. eGFR equations were better than creatinine alone at predicting 4CrCl. Adding cystatin C to estimates did not improve the bias or add accuracy. The MDRD 7 eGFR had the best combination of correlation, bias, percentage error and accuracy. None were near acceptable standards quoted in patients with chronic kidney disease (CKD. Conclusions. eGFR equations are not sufficiently accurate for use in critically ill patients with AKI. Incorporating serum cystatin C does not improve estimates. eGFR should not be used to describe renal function in patients with AKI. Standards of accuracy for validating eGFR need to be set.

  15. Effect of socio-demographic factors on endogenous biomarkers (cystatin C and creatinine) among elderly chronic kidney disease patients: a cross-sectional study.

    Science.gov (United States)

    Khan, Irfanullah; Khan, Amer Hayat; Adnan, Azreen Syazril; Sulaiman, Syed Azhar Syed; Hamzah, Azhar Bin Amir; Ahmed, Nafees; Khan, Amjad

    2018-06-01

    Creatinine is normally used to evaluate kidney function among elderly patients in clinical practice, which has been reported to be affected by socio-demographic factors like BMI and age. Cystatin C a newly introduced biomarker may be more efficient in identifying kidney function in obese and aged CKD patients. The aim of the current study was to assess the effect of BMI on endogenous biomarkers (cystatin C and creatinine) among elderly CKD patients in Malaysia, a first such study in the country. The current study was conducted at the Hospital University Sains Malaysia, Kelantan. A total of 300 elderly Malay participants ≥ 65 years, with CKD, were taken in study. Demographic data, blood pressure, weight, and height were documented. Serum creatinine was assayed by Chemistry Analyzer Model Architect-C8000 (Jaffe Method), while serum cystatin C was examined by Human cystatin C ELISA kit (Sigma-Aldrich) using Thermo Scientific Varioskan Flash ELISA reader. The study participants were divided into three groups on the basis of age. There was a statistically significant difference at the p value C levels were observed on the basis of patient's age and BMI. Cystatin C is not related to BMI and age among elderly chronic kidney disease patients. The study clearly evaluates the role of serum cystatin C as a good competitor of creatinine among the elderly CKD patients.

  16. Screening for renal insufficiency following ESUR (European Society of Urogenital Radiology) guidelines with on-site creatinine measurements in an outpatient setting

    Energy Technology Data Exchange (ETDEWEB)

    Ledermann, H.P.; Mengiardi, B.; Schmid, A. [IMAMED Radiologie Nordwest, Basel (Switzerland); Froehlich, J.M. [Guerbet AG, Medical Affairs, Zurich (Switzerland); University of Bern, Radiology Department, Bern (Switzerland)

    2010-08-15

    To report the results and implications for workflow following introduction of ESUR guidelines to screen for potential renal insufficiency (RI) in private practice with on-site creatinine measurements. A total of 1,766 consecutive outpatients scheduled for contrast-enhanced CT (CECT) completed the ESUR questionnaire enquiring about kidney disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout or use of nephrotoxic drugs. Patients with positive risk factors underwent on-site creatinine measurement and calculation of estimated glomerular filtration rate (eGFR). Attending radiologists adapted subsequent imaging depending on renal function and presence of risk factors. One or more ESUR risk factors were present in 796 (45.1%) patients, including hypertension (37.7%), nephrotoxic medication (21.3%), diabetes mellitus (8.0%), proteinuria (3.9%), renal disease (4.1%), gout (3.1%) and renal surgery (2.6%). Pre-procedural creatinine measurements revealed severe RI (eGFR < 30 ml min{sup -1} 1.73 m{sup -2}) in 10 (1.3%) and moderate RI (eGFR 30-59 ml min{sup -1} 1.73 m{sup -2}) in 106 (13.8%). Imaging work-up was adapted in 132 (16.6%) as follows: reduction of contrast material dose (n = 85), CT without contrast (n = 40), changeover to MRI (n = 3) or scintigraphy (n = 4). Screening for RI following ESUR guidelines requires creatinine measurements in nearly half of outpatients scheduled for CECT and reveals moderate to severe renal impairment in 6.6%. (orig.)

  17. Stamping SERS for creatinine sensing

    Science.gov (United States)

    Li, Ming; Du, Yong; Zhao, Fusheng; Zeng, Jianbo; Santos, Greggy M.; Mohan, Chandra; Shih, Wei-Chuan

    2015-03-01

    Urine can be obtained easily, readily and non-invasively. The analysis of urine can provide metabolic information of the body and the condition of renal function. Creatinine is one of the major components of human urine associated with muscle metabolism. Since the content of creatinine excreted into urine is relatively constant, it is used as an internal standard to normalize water variations. Moreover, the detection of creatinine concentration in urine is important for the renal clearance test, which can monitor the filtration function of kidney and health status. In more details, kidney failure can be imminent when the creatinine concentration in urine is high. A simple device and protocol for creatinine sensing in urine samples can be valuable for point-of-care applications. We reported quantitative analysis of creatinine in urine samples by using stamping surface enhanced Raman scattering (S-SERS) technique with nanoporous gold disk (NPGD) based SERS substrate. S-SERS technique enables label-free and multiplexed molecular sensing under dry condition, while NPGD provides a robust, controllable, and high-sensitivity SERS substrate. The performance of S-SERS with NGPDs is evaluated by the detection and quantification of pure creatinine and creatinine in artificial urine within physiologically relevant concentration ranges.

  18. Creatinine and urea biosensors based on a novel ammonium ion-selective copper-polyaniline nano-composite.

    Science.gov (United States)

    Zhybak, M; Beni, V; Vagin, M Y; Dempsey, E; Turner, A P F; Korpan, Y

    2016-03-15

    The use of a novel ammonium ion-specific copper-polyaniline nano-composite as transducer for hydrolase-based biosensors is proposed. In this work, a combination of creatinine deaminase and urease has been chosen as a model system to demonstrate the construction of urea and creatinine biosensors to illustrate the principle. Immobilisation of enzymes was shown to be a crucial step in the development of the biosensors; the use of glycerol and lactitol as stabilisers resulted in a significant improvement, especially in the case of the creatinine, of the operational stability of the biosensors (from few hours to at least 3 days). The developed biosensors exhibited high selectivity towards creatinine and urea. The sensitivity was found to be 85 ± 3.4 mAM(-1)cm(-2) for the creatinine biosensor and 112 ± 3.36 mAM(-1)cm(-2) for the urea biosensor, with apparent Michaelis-Menten constants (KM,app), obtained from the creatinine and urea calibration curves, of 0.163 mM for creatinine deaminase and 0.139 mM for urease, respectively. The biosensors responded linearly over the concentration range 1-125 µM, with a limit of detection of 0.5 µM and a response time of 15s. The performance of the biosensors in a real sample matrix, serum, was evaluated and a good correlation with standard spectrophotometric clinical laboratory techniques was found. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Hypotension, bedridden, leukocytosis, thrombocytopenia and elevated serum creatinine predict mortality in geriatric patients with fever.

    Science.gov (United States)

    Chung, Min-Hsien; Chu, Feng-Yuan; Yang, Tzu-Meng; Lin, Hung-Jung; Chen, Jiann-Hwa; Guo, How-Ran; Vong, Si-Chon; Su, Shih-Bin; Huang, Chien-Cheng; Hsu, Chien-Chin

    2015-07-01

    The geriatric population (aged ≥65 years) accounts for 12-24% of all emergency department (ED) visits. Of them, 10% have a fever, 70-90% will be admitted and 7-10% of will die within a month. Therefore, mortality prediction and appropriate disposition after ED treatment are of great concern for geriatric patients with fever. We tried to identify independent mortality predictors of geriatric patients with fever, and combine these predictors to predict their mortality. We enrolled consecutive geriatric patients visiting the ED between 1 June and 21 July 2010 with the following criteria of fever: a tympanic temperature ≥37.2°C or a baseline temperature elevated ≥1.3°C. We used 30-day mortality as the primary end-point. A total of 330 patients were enrolled. Hypotension, bedridden, leukocytosis, thrombocytopenia and serum creatinine >2 mg/dL, but not age, were independently associated with 30-day mortality. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) ranged from 18.2% to 90.9%, 34.7% to 100%, 9.0% to 100% and 94.5% to 98.2%, respectively, depending on how many predictors there were. The 30-day mortality increased with the number of independent mortality predictors. With at least four predictors, 100% of the patients died within 30 days. With none of the predictors, just 1.8% died. These findings might help physicians make decisions about geriatric patients with fever. © 2014 Japan Geriatrics Society.

  20. Digoxin serum levels with respect to some biochemical and clinical indicators

    Energy Technology Data Exchange (ETDEWEB)

    Sedlak, J; Curilla, E [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1984-10-01

    Digoxin serum levels were examined in 40 patients using enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) and correlated with levels of potassium, magnesium, creatinine, urea, glomerular filtration (GF) and with clinical signs of different degrees of digitalis serum concentration. The digoxin level assessed by ELISA and RIA methods correlated fairly closely. An average dependence was found between digoxin levels and levels of creatinine, urea and GF. A correlation was observed between a high level of digoxin and clinical signs of digitalis intoxication.

  1. Digoxin serum levels with respect to some biochemical and clinical indicators

    International Nuclear Information System (INIS)

    Sedlak, J.; Curilla, E.

    1984-01-01

    Digoxin serum levels were examined in 40 patients using enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) and correlated with levels of potassium, magnesium, creatinine, urea, glomerular filtration (GF) and with clinical signs of different degrees of digitalis serum concentration. The digoxin level assessed by ELISA and RIA methods correlated fairly closely. An average dependence was found between digoxin levels and levels of creatinine, urea and GF. A correlation was observed between a high level of digoxin and clinical signs of digitalis intoxication

  2. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies.

    Science.gov (United States)

    Reischies, Frederike M J; Raggam, Reinhard B; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-03-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with hematological malignancies. (This study has been registered at ClinicalTrials.gov under registration no. NCT01576653.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  3. Point of care creatinine measurement for diagnosis of renal disease using a disposable microchip

    NARCIS (Netherlands)

    Ávila Muñoz, Mónica; Floris, J.; Staal, S.S.; Ríos, Ángel; Eijkel, Jan C.T.; van den Berg, Albert

    2013-01-01

    A point-of-care device for the determination of elevated creatinine levels in blood is reported. This device potentially offers a new and simple clinical regime for the determination of creatinine that will give huge time savings and removal of several steps of determination. The test employs a

  4. Early rise in postoperative creatinine for identification of acute kidney injury after cardiac surgery.

    Science.gov (United States)

    Karkouti, Keyvan; Rao, Vivek; Chan, Christopher T; Wijeysundera, Duminda N

    2017-08-01

    Acute kidney injury (AKI) is a potentially serious complication of cardiac surgery. Treatment strategies are unlikely to prove efficacious unless patients are identified and treated soon after the onset of injury. In this observational study, we determined and validated the ability of an early rise in postoperative serum creatinine to identify patients who suffer AKI during cardiac surgery. The relationship between an early rise in creatinine (immediate postoperative / preoperative creatinine) and AKI (> 50% increase in creatinine by postoperative calendar days 1or 2) was determined by logistic regression modelling. Existing databases were used for model development (n = 4,820; one institution) and validation (n = 6,553; 12 institutions). Acute kidney injury occurred in 9.1% (n = 437) and 9.8% (n = 645) of patients in the development and validation sets, respectively. An early rise in creatinine was related to AKI (P 1.30 (n = 127), the sensitivity, specificity, positive, and negative predictive values for AKI in the development set were 20% (95% CI, 16 to 24), 99% (95% CI, 99 to 99), 68% (95% CI, 59 to 76), and 93% (95% CI, 92 to 93), respectively. In patients undergoing cardiac surgery with cardiopulmonary bypass, an early rise in postoperative creatinine is a useful marker for the early identification of AKI patients. This could allow inclusion of such patients in clinical trials of promising therapeutic strategies that need to be initiated soon after the onset of injury.

  5. Effect of lemongrass tea consumption on estimated glomerular filtration rate and creatinine clearance rate.

    Science.gov (United States)

    Ekpenyong, Christopher E; Daniel, Nyebuk E; Antai, Atim B

    2015-01-01

    The existing research findings regarding the effects of lemongrass (Cymbopogon citratus) tea on renal function indices are conflicting and inconclusive. In the present study, we investigated the effects of infusions prepared from C citratus leaves on creatinine clearance rate (CCr) and estimated glomerular filtration rate (eGFR) in humans. One hundred five subjects (55 men and 50 women) aged 18 to 35 years were randomly assigned to groups set to orally receive infusions prepared from 2, 4, or 8 g of C citratus leaf powder once daily, for 30 days. Serum and urinary levels of urea, creatinine, pH, specific gravity, uric acid, electrolytes, diuretic indices, and eGFR were assessed at days 0, 10, and 30 after the initiation of treatment. Results obtained on days10 and 30 were compared with baseline values. CCr and eGFR decreased significantly at day 30 in both male and female subjects in all the groups and in females treated with infusion prepared from 8 g of C citratus leaf powder for 10 days. At day 10, CCr and eGFR were unchanged in those treated with infusions prepared from 2 or 4 g of the leaf powder, whereas diuretic indices (urine volume, urination frequency, diuretic action, and saliuretic indices) increased above the baseline levels. Serum and urinary creatinine levels significantly increased (P < .05) in both male and female subjects in all the groups. Serum urea significantly increased in the groups treated with infusions prepared from 4 or 8 g of the leaf powder (P < .05) for 30 days. Serum electrolytes remained unchanged, but their urinary levels increased. We observed dose- and time-dependent adverse effects of C citratus on CCr and eGFR. At a high dose or with prolonged treatment with a low dose, eGFR decrease may be followed by a decline in the other renal function indices. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  6. Vitamin D status and 5-year changes in urine albumin creatinine ratio and parathyroid hormone in a general population

    DEFF Research Database (Denmark)

    Skaaby, Tea; Husemoen, Lise Lotte Nystrup; Pisinger, Charlotta

    2013-01-01

    and negatively correlated with glomerular filtration rate. We investigated the association between vitamin D status and 5-year changes in urine albumin creatinine ratio (UACR) and parathyroid hormone (PTH). A random sample of 6,784 individuals aged 30-60 years from a general population participated in the Inter......99 study in 1999-2001. Vitamin D (serum-25-hydroxyvitamin D) was measured at baseline by high-performance liquid chromatography. UACR and PTH were measured at baseline and follow-up. Increased UACR was defined as UACR >4.0 mg/g reflecting the upper quartile at baseline. We included 4,330 individuals...

  7. Increased serum urea to creatinine ratio and its negative correlation with arterial pressure in canine babesiosis.

    Science.gov (United States)

    Zygner, Wojciech; Gójska-Zygner, Olga

    2014-09-01

    The increase of the serum urea to creatinine ratio (UCR) was observed in dogs infected with Babesia canis. Previous studies have suggested that decrease of blood pressure can be one of the reasons for this phenomenon. In this work statistically significant increase of the UCR was observed in dogs with babesiosis. Comparison of the UCR between 23 azotaemic dogs and 25 non-azotaemic dogs infected with Babesia canis showed statistically significantly higher mean of the UCR in azotaemic dogs. Correlations between UCR and systolic, diastolic and mean arterial pressure (SAP, DAP and MAP) in 48 dogs infected with B. canis were negative (UCR and SAP: r = -0.3909; UCR and DAP: r = -0.3182; UCR and MAP: r = -0.3682) and statistically significant (p high, and there was no statistically significant correlation between UCR and arterial pressures in azotaemic dogs. Thus, it seems that decrease of blood pressure in dogs with babesiosis explains only partially the cause of increased UCR in infected dogs. The other authors suggested hyperureagenesis and myocardial injury as a potential reason for the increased UCR in canine babesiosis. Thus, further studies are needed to determine causes of increased UCR in dogs with babesiosis, especially on the connection between UCR changes and the concentrations of plasma cardiac troponins and ammonia, and the occurrence of occult blood on fecal examination.

  8. 50 years follow-up on plasma creatinine levels after spinal cord injury

    DEFF Research Database (Denmark)

    Elmelund, Marlene; Oturai, P S; Biering-Sørensen, F

    2014-01-01

    STUDY DESIGN: Retrospective chart review. OBJECTIVES: To investigate the role of plasma creatinine (p-creatinine) in monitoring renal deterioration in patients up to 50 years after spinal cord injury (SCI). SETTING: The Clinic for Spinal Cord Injuries, Rigshospitalet, Denmark. METHODS: A total...... of 119 patients with a traumatic SCI during the years 1944-1975 were included in the study. P-creatinine measurements, results from renography and glomerular filtration rate (GFR) measured with 51Cr-EDTA clearance were obtained from medical records and analyzed using a linear mixed model and linear...... regression analyses. RESULTS: When compared with median p-creatinine level in the first 5-year period after injury, the level of p-creatinine was stable throughout the first 30 years and decreased significantly after the 30th until 45th year post injury. Only patients with a functional distribution outside...

  9. Serum Soluble Fms-Like Tyrosine Kinase 1 (sFlt-1 Predicts the Severity of Acute Pancreatitis

    Directory of Open Access Journals (Sweden)

    Paulina Dumnicka

    2016-12-01

    Full Text Available Organ failure is the most important determinant of the severity of acute pancreatitis (AP. Soluble fms-like tyrosine kinase 1 (sFlt-1 is positively associated with organ failure in sepsis. Our aim was to evaluate the diagnostic utility of automated sFlt-1 measurements for early prediction of AP severity. Adult patients (66 with AP were recruited, including 46 with mild (MAP, 15 with moderately-severe (MSAP and 5 with severe AP (SAP. Serum and urine samples were collected twice. Serum sFlt-1 was measured with automated electrochemiluminescence immunoassay. Serum concentrations of sFlt-1 were significantly higher in patients with MSAP and SAP as compared to MAP. SAP patients had the highest concentrations. At 24 and 48 h, sFlt-1 positively correlated with inflammatory markers (leukocyte count, C-reactive protein, kidney function (creatinine, urea, cystatin C, serum and urine neutrophil gelatinase-associated lipocalin, urine albumin/creatinine ratio, D-dimer and angiopoietin-2. sFlt-1 positively correlated with the bedside index of severity in AP (BISAP score and the duration of hospital stay. Serum sFlt-1 above 139 pg/mL predicted more severe AP (MSAP + SAP. In the early phase of AP, sFlt-1 is positively associated with the severity of AP and predicts organ failure, in particular kidney failure. Serum sFlt-1 may be a practical way to improve early assessment of AP severity.

  10. Serum and urinary cystatin C in cats with feline immunodeficiency virus infection and cats with hyperthyroidism.

    Science.gov (United States)

    Ghys, Liesbeth Fe; Paepe, Dominique; Taffin, Elien Rl; Vandermeulen, Eva; Duchateau, Luc; Smets, Pascale My; Delanghe, Joris; Daminet, Sylvie

    2016-08-01

    The objective of this study was to investigate serum cystatin C (sCysC) and urinary cystatin C (uCysC) in cats with hyperthyroidism and cats with feline immunodeficiency virus (FIV). Thirty cats with FIV, 26 hyperthyroid cats and 28 healthy cats were included. sCysC and uCysC:creatinine (uCysC/uCr) ratio were measured with a human particle-enhanced nephelometric immunoassay, previously validated for feline CysC measurement. Routine renal variables (serum creatinine [sCr], urine specific gravity, urinary protein:creatinine ratio [UPC]) were also measured in the three groups. Cats with hyperthyroidism had significantly higher sCysC and higher uCysC/uCr ratio, lower sCr and a higher UPC than healthy cats. Cats with FIV infection did not show a significantly higher sCysC concentration but had a significantly higher sCr and UPC than healthy cats. uCysC could be detected in only four of them. This study demonstrated that sCysC is increased in cats with hyperthyroidism, in contrast with sCr, but not in cats with FIV. Many hyperthyroid cats, but only four cats with FIV, had an elevated uCysC/uCr ratio. Further studies may reveal if uCysC might be a valuable marker for tubular dysfunction in cats. © The Author(s) 2015.

  11. Association of high post-transplant soluble CD30 serum levels with chronic allograft nephropathy.

    Science.gov (United States)

    Grenzi, Patricia C; Campos, Érika F; Tedesco-Silva, Hélio; Felipe, Claudia R; Franco, Marcello F; Soares, Maria Fernanda; Medina-Pestana, José Osmar; Gerbase-Delima, Maria

    2013-12-01

    The purpose of this study was to evaluate the association of post-transplant soluble CD30 (sCD30) levels, isolated or in combination with of anti-HLA class II antibodies and of serum creatinine levels, with kidney graft loss due to chronic allograft nephropathy (CAN), and type of lesions in graft biopsies for cause. The study comprised 511 first kidney graft recipients, transplanted at a single center, with a graft functioning for at least 2.8 years. A single blood sample was collected from each patient. sCD30 levels were determined by ELISA, and HLA antibodies by Luminex assay. The minimum follow-up after testing was 9.3 years. High sCD30 levels, set at sCD30 ≥ 34.15 ng/mL, the presence of HLA class II antibodies, and serum creatinine ≥ 1.9 mg/dL were independently associated with CAN-graft loss (P values sCD30 levels and creatinine were independently associated with interstitial lesions. Post-transplant sCD30 serum levels, especially in conjunction with information regarding HLA class II antibodies and serum creatinine levels, provide valuable information regarding graft outcome and could be useful for the management of kidney transplant recipients. © 2013.

  12. Comparison between swallowing and chewing of garlic on levels of serum lipids, cyclosporine, creatinine and lipid peroxidation in Renal Transplant Recipients

    Directory of Open Access Journals (Sweden)

    Ghorbanihaghjo Amir

    2005-05-01

    Full Text Available Abstract Abstract Hyperlipidemia and increased degree of oxidative stress are among the important risk factors for Atherosclerosis in renal transplant recipients (RTR. The Medical treatment of hyperlipidemia in RTR because of drugs side effects has been problematic, therefore alternative methods such as using of Garlic as an effective material in cholesterol lowering and inhibition of LDL Oxidation has been noted. For evaluation of garlic effect on RTR, 50 renal transplant patients with stable renal function were selected and divided into 2 groups. They took one clove of garlic (1 gr by chewing or swallowing for two months, after one month wash-out period, they took garlic by the other route. Results indicated that although lipid profile, BUN, Cr, serum levels of cyclosporine and diastolic blood pressure did not change, Systolic blood pressure decreased from138.2 to 132.8 mmHg (p=0.001 and Malondialdehyde (MDA decreased from 2.4 to1.7 nmol/ml (p=0.009 by swallowing route, Cholesterol decreased from 205.1 to 195.3 mg/dl (p=0.03, triglyceride decreased from 195.7 to 174.8 mg/dl (p=0.008, MDA decreased from 2.5 to 1.6 nmol/ml (p=0.001, systolic blood pressure decreased from 137.5 to 129.8 mmHg (p=0.001, diastolic blood pressure decreased from 84.6 to 77.6 mmHg (p=0.001 and Cr decreased from 1.51 to 1.44 mg/dl (p=0.03 by chewing route too. However HDL, LDL and cyclosporine serum levels had no significant differences by both of swallowing and chewing routes. We conclude that undamaged garlic (swallowed had no lowering effect on lipid level of serum. But Crushed garlic (chewed reduces cholesterol, triglyceride, MDA and blood pressure. Additionally creatinine reduced without notable decrease in cyclosporine serum levels may be due to cyclosporine nephrotoxicity ameliorating effect of garlic.

  13. Serum amylase and lipase activities after exploratory laparotomy in dogs.

    Science.gov (United States)

    Bellah, J R; Bell, G

    1989-09-01

    Serum amylase and lipase activities and creatinine concentration were determined before surgery, and at 1 and 2 days after exploratory laparotomy in 24 dogs. Examination of all viscera was done during each laparotomy, but a surgical procedure was not performed. The mean serum activities for lipase were: before surgery, 0.71 (0.0 to 2.0) Cherry Crandall units (CCU)/L; 1 day after surgery, 2.1 (0.0 to 4.5) CCU/L; and 2 days after surgery, 1.19 (0.0 to 3.9) CCU/L. The mean serum activities for amylase were: before surgery, 1,958 (1,027 to 3,426) IU/L; 1 day after surgery, 1,538 (937 to 2,659) IU/L; and 2 days after surgery, 1,663 (1,066 to 2,274) IU/L. Serum creatinine concentrations before surgery, 1 day after surgery, and 2 days after surgery were 0.88 (0.2 to 1.7) mg/dl, 0.78 (0.4 to 1.3) mg/dl, and 0.78 (0.3 to 1.3) mg/dl, respectively. Mean preoperative, day-1, and day-2 serum amylase activities and serum creatinine concentrations did not differ significantly from each other. Mean preoperative and day-2 serum lipase activities did not differ significantly; however, mean serum lipase activity was significantly greater when day 1 activities were compared with preoperative activities (P = 0.0002). Post-mortem examinations revealed no gross or histologic evidence of pancreatitis in any dog. The results of this study show that a 3 or more fold increase in serum lipase activity may occur after routine exploratory laparotomy in dogs without clinical signs or gross evidence of pancreatitis. Histologic evidence of pancreatitis was not found in the right pancreatic lobes in any dog.

  14. Pre-operative renal volume predicts peak creatinine after congenital heart surgery in neonates.

    Science.gov (United States)

    Carmody, J Bryan; Seckeler, Michael D; Ballengee, Cortney R; Conaway, Mark; Jayakumar, K Anitha; Charlton, Jennifer R

    2014-10-01

    Acute kidney injury is common in neonates following surgery for congenital heart disease. We conducted a retrospective analysis to determine whether neonates with smaller pre-operative renal volume were more likely to develop post-operative acute kidney injury. We conducted a retrospective review of 72 neonates who underwent congenital heart surgery for any lesion other than patent ductus arteriosus at our institution from January 2007 to December 2011. Renal volume was calculated by ultrasound using the prolate ellipsoid formula. The presence and severity of post-operative acute kidney injury was determined both by measuring the peak serum creatinine in the first 7 days post-operatively and by using the Acute Kidney Injury Network scoring system. Using a linear change point model, a threshold renal volume of 17 cm³ was identified. Below this threshold, there was an inverse linear relationship between renal volume and peak post-operative creatinine for all patients (p = 0.036) and the subgroup with a single morphologic right ventricle (p = 0.046). There was a non-significant trend towards more acute kidney injury using Acute Kidney Injury Network criteria in all neonates with renal volume ≤17 cm³ (p = 0.11) and in the subgroup with a single morphologic right ventricle (p = 0.17). Pre-operative renal volume ≤17 cm³ is associated with a higher peak post-operative creatinine and potentially greater risk for post-operative acute kidney injury for neonates undergoing congenital heart surgery. Neonates with a single right ventricle may be at higher risk.

  15. Comparison of renal function assessment by cystatin c and creatinine based equations for e-gfr in type 2 diabetics in different stages of albuminuria

    International Nuclear Information System (INIS)

    Qamar, A.; Ahmad, T.M.; Hayat, A.; Khan, M.A.; Rehman, S. Z.

    2017-01-01

    To compare e-GFR estimated by creatinine or cystatin C based and combined creatinine and cystatin C based equations in type 2 diabetics in different stages of albuminuria. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Chemical Pathology, Army Medical College Rawalpindi in collaboration with endocrinology outpatient department Military Hospital Rawalpindi, from Nov 2015 to Nov 2016. Material and Methods: A total of 119 type 2 diabetic subjects of either gender, aged 30- 60 years were enrolled in the study with duration of diabetes less than 15 years and were divided into further sub groups on the basis of degree of albuminuria determined by spot urine albumin to creatinine ratio (uACR). Fifty age matched disease free controls with no history of any systemic disease were also included in the study. Known patients of type 1 diabetes, chronic inflammatory disorders, uncontrolled hypertension, thyroid disease, chronic kidney disease, on lipid lowering drugs, steroids, ACE inhibitors and pregnant ladies were excluded from the study. Serum creatinine serum cystatin C were assessed on fully automated chemistry analyzer selectra. E-GFR was calculated by online GFR calculator by National Kidney Foundation. Comparison of means of e-GFR calculated by various equations was carried out by one way ANOVA and post-hoc Tukey tests. Degree of agreement between various equations for the estimation of GFR was assessed by kappa statistics. A p-value less than 0.05 were considered statistically significant. Results: Mean e-GFR (ml/min/1.73m2) was lowest in cystatin C based CKD-EPI equation (89.56 +- 39.84) followed by combined cystatin C and creatinine based CKD-EPI (92.34 +- 37.88). Values of e-GFR by creatinine based CKD-EPI equation (95.84 +- 27.24), and by creatinine based MDRD equation (105.37 +- 64.98) were both higher. In creatinine based MDRD, equation normo albuminuria and micro albuminuria groups did not show statistically

  16. The influence of ketoacids on plasma creatinine assays in diabetic ketoacidosis

    NARCIS (Netherlands)

    Kemperman, F. A.; Weber, J. A.; Gorgels, J.; van Zanten, A. P.; Krediet, R. T.; Arisz, L.

    2000-01-01

    OBJECTIVE: Analysis of the interference of ketoacids on various routine plasma creatinine assays during a clinical episode of diabetic ketoacidosis (DKA). DESIGN: Observational study. Blood samples were drawn before, during and after standard in-hospital treatment. Plasma creatinine was measured

  17. Association of Serum Adropin Concentrations with Diabetic Nephropathy

    Directory of Open Access Journals (Sweden)

    Wenchao Hu

    2016-01-01

    Full Text Available Objective. Adropin is a newly identified regulatory protein encoded by the Enho gene and is critically involved in energy homeostasis and insulin sensitivity. This study aims to determine the correlation of serum adropin concentrations with diabetic nephropathy (DN. Methods. This study consisted of 245 patients with type 2 diabetes mellitus (T2DM and 81 healthy subjects. Then T2DM patients were divided into normoalbuminuria, microalbuminuria, and macroalbuminuria subgroups based on urine albumin to creatinine ratio (ACR. Results. T2DM patients showed significantly lower serum adropin concentrations than those in the controls. T2DM patients with macroalbuminuria had significantly decreased serum adropin concentrations compared with the other three groups. In addition, T2DM patients with microalbuminuria showed lower serum adropin concentrations than those in patients with normoalbuminuria. Logistic regression analysis showed that serum adropin was correlated with decreased risk of developing T2DM and DN. Pearson correlation analysis indicated that serum adropin was negatively correlated with body mass index (BMI, blood urea nitrogen, creatinine, and ACR and positively correlated with glomerular filtration rate. Furthermore, multiple linear regression analysis showed that BMI and ACR were negatively correlated with serum adropin levels. Conclusion. Serum adropin concentrations are negatively associated with renal function. Adropin may be implicated in the pathogenesis of DN development.

  18. Changes in serum biochemical factors associated with opium addiction after addiction desertion.

    Science.gov (United States)

    Afarinesh, Mohammad Reza; Haghpanah, Tahereh; Divsalar, Kouros; Dehyadegary, Elham; Shaikh-Aleslami, Azar; Mahmoodi, Majid

    2014-01-01

    The long time use of opium has some effects on serums biochemical factors, the determination of this variation is a new approach in understanding off addiction and relive of drug abuser health. Hence in this study, these indicators in person who were withdrawing of opium have been studied. In this cross-sectional study bloods biochemical factors such as fasting blood sugar (FBS), sodium (Na), calcium (Ca), uric acid (UA), blood urea nitrogen (BUN), creatinine, cholesterol, total protein, and fibrinogen in three groups serum were studied: (1) Who had been permanent opium users more than 2 years (case). (2) Dependent person who has taken one month addiction withdrawal course (control). (3) A healthy group that had been demographically similar to the other groups. According to these study findings, FBS serum level in the case group is lower than control group. Serum level of Na, creatinine, and blood triglyceride (TG) in case study are higher than group control. Concentration of potassium, Ca, UA, BUN, cholesterol, total serum protein, fibrinogen, and thrombin time in case study and group control showed no significant difference. Also, in withdrawing case serum level of Na, Ca, UA, BUN, creatinine, and TG significantly increase and thrombin time decrease. According to this study not only the longtime use of opium but also opium with drawerin opium dependent people can change their serum biochemical factors. So recognition, treatment, and prevention of this change could be a new step in improving of health and condition of patients.

  19. Improved Performance of the Potentiometric Biosensor for the Determination of Creatinine

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Rasmussen, Claus/Dallerup; Zachau-Christiansen, Birgit

    2007-01-01

    The development of potentiometric biosensors for the determination of creatinine is attractive because it is a frequently analysed species in clinical chemistry. Contemporary methods of analysing creatinine engage chemicals harmful to the environment and generate large volumes of waste disposals....... By introducing a membrane-based potentiometric biosensor with immobilised creatinine deaminase, the measurements can be performed by miniaturised portable devices that are easy to handle and allow rapid analysis at a minimum consumption of chemicals. Thus, the enzymatic creatinine biosensors was revisited...... performed by flow injection analysis (FIA) showed that the response time could be lowered to approx. 30 sec. using sample volumes of 30 L. Interferences were corrected for by application of the Nicolsky-Eisenman equation thus allowing determination of creatinine in matrices resembling those of clinical...

  20. Direct determination of creatinine based on poly(ethyleneimine)/phosphotungstic acid multilayer modified electrode.

    Science.gov (United States)

    Han, Ping; Xu, Shimei; Feng, Shun; Hao, Yanjun; Wang, Jide

    2016-05-01

    In this work, the direct determination of creatinine was achieved using a poly(ethyleneimine)/phosphotungstic acid multilayer modified electrode with the assistance of Copper(II) ions by cyclic voltammetry. The quantity of creatinine were determined by measuring the redox peak current of Cu(II)-creatinine complex/Cu(I)-creatinine complex. Factors affecting the response current of creatinine at the modified electrode were optimized. A linear relationship between the response current and the concentration of creatinine ranging from 0.125 to 62.5μM was obtained with a detection limit of 0.06μM. The proposed method was applied to determine creatinine in human urine, and satisfied results were gotten which was validated in accordance with high performance liquid chromatography. The proposed electrode provided a promising alternative in routine sensing for creatinine without enzymatic assistance. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  2. Interrelationship of βeta-2 microglobulin, blood urea nitrogen and creatinine in streptozotocin -induced diabetes mellitus in rabbits

    Directory of Open Access Journals (Sweden)

    Shahram Javadi

    2013-12-01

    Full Text Available Measurement of serum creatinine (Cr and blood urea nitrogen (BUN are used as indicators of glomerular filtration rate. The increased levels of these biomarkers are usually detectable at advanced stages of kidney complications. The aim of this study was to find the interrelationship of beta-2 microglobulin (β2M, BUN and Cr in streptozotocin (STZ-induced diabetes mellitus in rabbits. Diabetes was induced by a single intraperitoneal (IP injection of 65 mg kg-1 of STZ in rabbits. The levels of serum insulin, glucose and three above mentioned biomarkers were measured one day before (day -1 and on days 1-3 after injection of STZ and continued weekly to the end of the experiment (12 weeks. A statistically significant increase of serum β2M, BUN, Cr and glucose levels, and a significant decrease of insulin levels were observed in diabetic animals. However, β2M levels increased as early as one day after STZ injection compared to Cr and BUN that elevated at day two, suggesting a probable diagnostic advantage of β2M over currently used biomarkers in diabetic related kidney complications.

  3. Iodine and creatinine testing in urine dried on filter paper

    Energy Technology Data Exchange (ETDEWEB)

    Zava, Theodore T., E-mail: ttzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Kapur, Sonia, E-mail: soniak@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Zava, David T., E-mail: dzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States)

    2013-02-18

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R{sup 2} = 0.9483; creatinine: R{sup 2} = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs.

  4. Iodine and creatinine testing in urine dried on filter paper

    International Nuclear Information System (INIS)

    Zava, Theodore T.; Kapur, Sonia; Zava, David T.

    2013-01-01

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R 2 = 0.9483; creatinine: R 2 = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs

  5. Analysis of clinical factors for the determination of optimal serum level of thyrotropin after recombinant human thyroid-stimulating hormone administration

    International Nuclear Information System (INIS)

    Son, Seung Hyun; Lee, Sang Woo; Jung, Ji Hoon; Kim, Choon Young; Kim, Do Hoon; Jeong, Shin Young; Ahn, Byeong Cheol; Lee, Jae Tae

    2015-01-01

    To determine the optimal levels of thyroid-stimulating hormone (TSH) levels after administration of recombinant human TSH (rhTSH) to patients with differentiated thyroid cancer (DTC), we have analyzed the clinical parameters that affected the degree of the increase in serum levels of TSH. We retrospectively analyzed 276 patients with differentiated thyroid cancer (DTC), post-thyroidectomy and remnant ablation. Pearson’s correlation coefficient test was used to evaluate the correlation between serum levels of TSH after rhTSH stimulation and various clinical factors, including age, sex, height, weight, body mass index (BMI), body surface area (BSA), serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate (GFR). Linear regression analysis was used to determine the predictors of the degree of increase in serum TSH level after rhTSH stimulation. After the rhTSH injections, all subjects achieved TSH levels of >30 μU/mL, with a mean of 203.8 ± 83.4 μU/mL. On univariate analysis, age (r = 0.255) and serum creatinine (r = 0.169) level were positive predictors for higher levels of serum TSH after rhTSH stimulation, while weight (r = –0.239), BMI (r = –0.223), BSA (r = –0.217), and estimated GFR (r = –0.199) were negative predictors. Multiple linear regression analysis revealed that serum creatinine was the most powerful independent predictor for serum levels of TSH, followed by age, BSA, and BMI. An increment in serum TSH after rhTSH stimulation was significantly affected by age, BSA, BMI, and creatinine, with creatinine being the most powerful predictor. By understanding the difference in the increased levels of TSH in various subjects, their dose of rhTSH can be adjusted during scheduling for radioiodine ablation, or during follow-up (recurrence surveillance) after surgery and ablation

  6. Analysis of clinical factors for the determination of optimal serum level of thyrotropin after recombinant human thyroid-stimulating hormone administration

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seung Hyun; Lee, Sang Woo; Jung, Ji Hoon; Kim, Choon Young; Kim, Do Hoon; Jeong, Shin Young; Ahn, Byeong Cheol; Lee, Jae Tae [Dept. of Nuclear Medicine, Kyungpook National University Medical Center and School of Medicine, Daegu (Korea, Republic of)

    2015-12-15

    To determine the optimal levels of thyroid-stimulating hormone (TSH) levels after administration of recombinant human TSH (rhTSH) to patients with differentiated thyroid cancer (DTC), we have analyzed the clinical parameters that affected the degree of the increase in serum levels of TSH. We retrospectively analyzed 276 patients with differentiated thyroid cancer (DTC), post-thyroidectomy and remnant ablation. Pearson’s correlation coefficient test was used to evaluate the correlation between serum levels of TSH after rhTSH stimulation and various clinical factors, including age, sex, height, weight, body mass index (BMI), body surface area (BSA), serum blood urea nitrogen, creatinine, and estimated glomerular filtration rate (GFR). Linear regression analysis was used to determine the predictors of the degree of increase in serum TSH level after rhTSH stimulation. After the rhTSH injections, all subjects achieved TSH levels of >30 μU/mL, with a mean of 203.8 ± 83.4 μU/mL. On univariate analysis, age (r = 0.255) and serum creatinine (r = 0.169) level were positive predictors for higher levels of serum TSH after rhTSH stimulation, while weight (r = –0.239), BMI (r = –0.223), BSA (r = –0.217), and estimated GFR (r = –0.199) were negative predictors. Multiple linear regression analysis revealed that serum creatinine was the most powerful independent predictor for serum levels of TSH, followed by age, BSA, and BMI. An increment in serum TSH after rhTSH stimulation was significantly affected by age, BSA, BMI, and creatinine, with creatinine being the most powerful predictor. By understanding the difference in the increased levels of TSH in various subjects, their dose of rhTSH can be adjusted during scheduling for radioiodine ablation, or during follow-up (recurrence surveillance) after surgery and ablation.

  7. Serum total proteins and creatinine levels in experimental gambian ...

    African Journals Online (AJOL)

    Attempt was therefore made to evaluate the effect of two strains of Trypanosoma brucei gambiense on total proteins and other serum biochemical parameters using vervet monkeys as a model. The outcome of both strains in vervet monkeys was traumatic as the monkeys died from infection 12 – 15 weeks post infection while ...

  8. Serum Cistatin C in patients with delayed graft function

    Directory of Open Access Journals (Sweden)

    Todor Gruev

    2006-04-01

    Full Text Available Despite recent studies showing that serum Cystatin C(CysC is a better marker for glomerular filtration rate (GFR than the ubiquitously used creatinine, the clinical utility of this remains to be evaluated. This marker is very sensitive for alograft function after renal transplantation. Concentration of CysC was compared with that of creatinine. Decreased renal function was followed in 64 transplanted patients. Plasma CysC significantly correlated (r=0.625, p<0.001 with creatinine in healthy controls. In these patients the mean plasma creatinine and Cystatin C concentrations were: 81+/-13 mmol/L,0.90 +/-0.22 mg/L, respectively. Plasma Cystatin C and creatinine significantly correlated throughout the post-transplantation period (r=0.686, p<0.001, but we confirmed differences between kinetics of these parameters. In the first four days after transplantation the CysC concentration was normalized faster than creatinine concentration. Development of acute rejection episode ( between 5 and 7 days showed high sensitivity and specificity of the changes of CysC compared with those of creatinine

  9. Effect of fasting ramadan in diabetes control status - application of extensive diabetes education, serum creatinine with HbA1c statistical ANOVA and regression models to prevent hypoglycemia.

    Science.gov (United States)

    Aziz, Kamran M A

    2013-09-01

    Ramadan fasting is an obligatory duty for Muslims. Unique physiologic and metabolic changes occur during fasting which requires adjustments of diabetes medications. Although challenging, successful fasting can be accomplished if pre-Ramadan extensive education is provided to the patients. Current research was conducted to study effective Ramadan fasting with different OHAs/insulins without significant risk of hypoglycemia in terms of HbA1c reductions after Ramadan. ANOVA model was used to assess HbA1c levels among different education statuses. Serum creatinine was used to measure renal functions. Pre-Ramadan diabetes education with alteration of therapy and dosage adjustments for OHAs/insulin was done. Regression models for HbA1c before Ramadan with FBS before sunset were also synthesized as a tool to prevent hypoglycemia and successful Ramadan fasting in future. Out of 1046 patients, 998 patients fasted successfully without any episodes of hypoglycemia. 48 patients (4.58%) experienced hypoglycemia. Χ(2) Test for CRD/CKD with hypoglycemia was also significant (p-value Ramadan diabetes management. Some relevant patents are also outlined in this paper.

  10. End-Stage Renal Disease Outcomes among the Kaiser Permanente Southern California Creatinine Safety Program (Creatinine SureNet): Opportunities to Reflect and Improve.

    Science.gov (United States)

    Sim, John J; Batech, Michael; Danforth, Kim N; Rutkowski, Mark P; Jacobsen, Steven J; Kanter, Michael H

    2017-01-01

    The Kaiser Permanente Southern California (KPSC) creatinine safety program (Creatinine SureNet) identifies and outreaches to thousands of people annually who may have had a missed diagnosis for chronic kidney disease (CKD). We sought to determine the value of this outpatient program and evaluate opportunities for improvement. Longitudinal cohort study (February 2010 through December 2015) of KPSC members captured into the creatinine safety program who were characterized using demographics, laboratory results, and different estimations of glomerular filtration rate. Age- and sex-adjusted rates of end-stage renal disease (ESRD) were compared with those in the overall KPSC population. Among 12,394 individuals, 83 (0.7%) reached ESRD. The age- and sex-adjusted relative risk of ESRD was 2.7 times higher compared with the KPSC general population during the same period (94.7 vs 35.4 per 100,000 person-years; p creatinine measurements, only 13% had a urine study performed (32% among patients with confirmed CKD). Our study found a higher incidence of ESRD among individuals captured into the KPSC creatinine safety program. If the Chronic Kidney Disease Epidemiology Collaboration equation were used, fewer people would have been captured while improving the accuracy for diagnosing CKD. Urine testing was low even among patients with confirmed CKD. Our findings demonstrate the importance of a creatinine safety net program in an integrated health system but also suggest opportunities to improve CKD care and screening.

  11. Influência da temperatura e do tempo de armazenamento nas dosagens bioquímicas de uréia e creatinina em soro ou plasma caninos Effect of temperature and storage time on urea and creatinine dosages from canine serum or plasma

    Directory of Open Access Journals (Sweden)

    S.T. Fernandes

    2001-12-01

    Full Text Available O trabalho teve como objetivos avaliar algumas condições de estocagem de soro e de plasma com EDTA 10% utilizados para determinação dos valores de uréia e creatinina em cães, e avaliar a possibilidade de substituir o soro pelo plasma conservado com EDTA 10%. Foram realizadas 3600 análises (1800 amostras de soro e 1800 de plasma com amostras que permaneceram em temperaturas ambiente, de refrigeração e de congelamento. As análises foram realizadas imediatamente após a obtenção da amostra (tempo 0 e após 2, 6, 12, 24, 72 horas e 30 e 60 dias após a coleta do sangue. Os resultados permitiram concluir que a uréia conservou-se por mais tempo na amostra sérica refrigerada até 30 dias e a creatinina na amostra sérica congelada até 72h. O soro mostrou mais estabilidade que o plasma em todas as condições de estoque estabelecidas.Aiming to evaluating some conditions of EDTA 10% serum and plasma storage for urea and creatinine values determinations in canines as well as analyzing the possibility of serum substitution by plasma, a total of 3600 samples (1800 serum and 1800 of plasma were analyzed at room, refrigeration and freezing temperatures. Different time intervals were used in the analysis: immediately after sampling (time 0, and at 2, 6, 12, 24, and 72 hours, and 30 and 60 days after the blood collection. The data showed that urea remains conserved for more time in the refrigerated serum sample until 30 days and the creatinine in the frozen serum sample until 72 hours. Serum showed more stability than plasma in all storage conditions established.

  12. Clinical significance of serum and urinary HER2/neu protein levels in primary non-muscle invasive bladder cancer

    Directory of Open Access Journals (Sweden)

    Ozgur Arikan

    2015-12-01

    Full Text Available Objective: We aimed to compare serum and urinary HER2/neu levels between healthy control group and patients with non-muscle invasive bladder cancer. Additionally, we evaluated relationship of HER2/neu levels with tumor stage, grade, recurrence and progression. Materials and Methods: Fourty-four patients with primary non-muscle invasive bladder tumors (Group 2 and 40 healthy control group (Group 1 were included the study. Blood and urinary samples were collected from all patients and HER2/neu levels were measured by ELISA method. Blood and urinary HER2/neu levels and additionally, ratio of urinary HER2/neu levels to urinary creatinine levels were recorded. Demographic data and tumor characteristics were recorded. Results: Mean serum HER2/neu levels were similar between two groups and statistically significant difference wasn't observed. Urinary HER2/neu levels were significantly higher in group 2 than group 1. Ratio of urinary HER2/neu to urinary creatinine was significantly higher in group 2 than group 1, (p=0,021. Serum and urinary HER2/ neu levels were not associated with tumor stage, grade, recurrence and progression while ratio of urinary HER2/neu to urinary creatinin levels were significantly higher in high-grade tumors. HER2/neu, the sensitivity of the test was found to be 20.5%, and the specificity was 97.5%, also for the urinary HER2/neu/urinary creatinine ratio, the sensitivity and specificity of the test were found to be 31.8% and 87.5%, respectively. Conclusions: Urinary HER2/neu and ratio of urinary creatinine urine were significantly higher in patients with bladder cancer compared to healthy subjects. Large series and controlled studies are needed for use as a tumor marker.

  13. Frequency and causes of discrepancy between Kt/V and creatinine clearance.

    Science.gov (United States)

    Satko, S G; Burkart, J M; Bleyer, A J; Jordan, J R; Manning, T

    1999-01-01

    This study examines the frequency of discrepancy between Kt/V urea and creatinine clearance (Ccr) measurements in patients on peritoneal dialysis (PD) and the reasons for this discrepancy. Nonrandomized, retrospective data analysis. Single PD unit of a university teaching hospital. All adult patients receiving PD at our center from January 1995 to December 1996. Actual (a) and desired (d) body weight (BW) were used to calculate urea volume of distribution (V) and body surface area (BSA). Patients were divided into four groups based upon their total small solute clearances (Kt/V and Ccr, normalized by actual weight) and three additional groups based upon actual/desired (a/d) body weight ratio. An additional analysis was performed for the subset of anuric patients. Data collected for all patients included the following: total Kt, total Ccr, 4-hour dialysate/ plasma (D/P) creatinine, serum albumin concentration, duration of PD, actual body weight, age, and height. Twenty-three percent of the clearance measurements in our study were discrepant, defined as having values for either Kt/V or Ccr (but not both) above the accepted targets of Kt/V > or = 2.0/wk and Ccr > or = 60 L/wk/ 1.73 m2. Patients with both values above target are more likely to have higher residual renal function. Patients who are significantly less than BWd and patients on PD for a longer time are more likely to have adequate Kt/V but not Ccr. Furthermore, patients who are less than 90% or greater than 110% of BWd have markedly different values for Kt/V and Ccr when BWa versus BWd values are used. Kt/V and Ccr values are frequently discrepant; a number of factors affect these two measurements to varying degrees, including weight, degree of residual renal function, and duration of PD.

  14. Changes in Serum Biochemical Factors Associated with Opium Addiction after Addiction Desertion

    Science.gov (United States)

    Afarinesh, Mohammad Reza; Haghpanah, Tahereh; Divsalar, Kouros; Dehyadegary, Elham; Shaikh-Aleslami, Azar; Mahmoodi, Majid

    2014-01-01

    Background The long time use of opium has some effects on serums biochemical factors, the determination of this variation is a new approach in understanding off addiction and relive of drug abuser health. Hence in this study, these indicators in person who were withdrawing of opium have been studied. Methods In this cross-sectional study bloods biochemical factors such as fasting blood sugar (FBS), sodium (Na), calcium (Ca), uric acid (UA), blood urea nitrogen (BUN), creatinine, cholesterol, total protein, and fibrinogen in three groups serum were studied: (1) Who had been permanent opium users more than 2 years (case). (2) Dependent person who has taken one month addiction withdrawal course (control). (3) A healthy group that had been demographically similar to the other groups. Findings According to these study findings, FBS serum level in the case group is lower than control group. Serum level of Na, creatinine, and blood triglyceride (TG) in case study are higher than group control. Concentration of potassium, Ca, UA, BUN, cholesterol, total serum protein, fibrinogen, and thrombin time in case study and group control showed no significant difference. Also, in withdrawing case serum level of Na, Ca, UA, BUN, creatinine, and TG significantly increase and thrombin time decrease. Conclusion According to this study not only the longtime use of opium but also opium with drawerin opium dependent people can change their serum biochemical factors. So recognition, treatment, and prevention of this change could be a new step in improving of health and condition of patients. PMID:25984281

  15. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  16. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  17. Creatinina sérica, cistatina C e proteína β-traço no estadiamento diagnóstico e na predição da progressão da doença renal crônica não diabética Serum creatinine, cystatin C, and β-trace protein in diagnostic staging and predicting progression of primary nondiabetic chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Katharina-Susanne Spanaus

    2011-02-01

    Full Text Available HISTÓRICO: A redução da função renal basal é um fator de risco bem definido para a progressão da doença renal crônica (DRC. Avaliamos a taxa de filtração glomerular (TFG medida e os marcadores séricos creatinina, cistatina C e proteína χ-traço (PBT para a acurácia diagnóstica na definição do estágio da lesão renal e como preditores do risco de progressão da DRC. MÉTODOS: Dosamos as concentrações dos marcadores em 227 pacientes com DRC primária não diabética e com vários graus de lesão renal e seguimos 177 pacientes prospectivamente por até sete anos para avaliar a progressão da DRC. RESULTADOS: No início, creatinina, cistatina C e PBT se correlacionaram fortemente com a TFG medida pela depuração do ioexol. As concentrações dos três marcadores aumentaram progressivamente com a diminuição da TFG, e seus desempenhos diagnósticos para a detecção até mesmo de discretas deteriorações da função renal (TFG INTRODUCTION: Impaired baseline kidney function is a well-defined risk factor for progression of chronic kidney disease (CKD. We evaluated measured glomerular filtration rate (GFR and the serum markers creatinine, cystatin C, and χ-trace protein (BTP for diagnostic accuracy in defining the stage of kidney impairment and as risk predictors of CKD progression. METHODS: We measured serum marker concentrations in 227 patients with primary nondiabetic CKD and various degrees of renal impairment and followed 177 patients prospectively for up to seven years to assess progression of CKD. RESULTS: At baseline, creatinine, cystatin C, and BTP were strongly correlated with GFR as measured by iohexol clearance. Concentrations of all three markers increased progressively with decreasing GFR, and their diagnostic performance for the detection of even minor deteriorations of renal function (GFR < 90 ml · min-1 · (1.73 m²-1 was similar. Sixty-five patients experienced progression of CKD, defined as doubling of

  18. Automated urinalysis technique determines concentration of creatine and creatinine by colorimetry

    Science.gov (United States)

    Rho, J. H.

    1967-01-01

    Continuous urinalysis technique is useful in the study of muscle wastage in primates. Creatinine concentration in urine is determined in an aliquot mixture by a color reaction. Creatine is determined in a second aliquot by converting it to creatinine and measuring the difference in color intensity between the two aliquots.

  19. Reference intervals for selected serum biochemistry analytes in cheetahs Acinonyx jubatus.

    Science.gov (United States)

    Hudson-Lamb, Gavin C; Schoeman, Johan P; Hooijberg, Emma H; Heinrich, Sonja K; Tordiffe, Adrian S W

    2016-02-26

    Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L - 166 mmol/L), potassium (3.9 mmol/L - 5.2 mmol/L), magnesium (0.8 mmol/L - 1.2 mmol/L), chloride (97 mmol/L - 130 mmol/L), urea (8.2 mmol/L - 25.1 mmol/L) and creatinine (88 µmol/L - 288 µmol/L). Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  20. Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure.

    Science.gov (United States)

    Cvan Trobec, Katja; Kerec Kos, Mojca; von Haehling, Stephan; Anker, Stefan D; Macdougall, Iain C; Ponikowski, Piotr; Lainscak, Mitja

    2015-12-01

    To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simultaneously, renal function was estimated with five creatinine-based equations (four- and six-variable Modification of Diet in Renal Disease, Cockcroft-Gault, Cockcroft-Gault adjusted for lean body mass, Chronic Kidney Disease Epidemiology Collaboration equation) and body composition was assessed using bioimpedance and dual-energy x-ray absorptiometry. Over a median follow-up of 7.5 months (range 6-17 months), iohexol clearance significantly declined (52.8 vs 44.4 mL/[min ×1.73 m2], P=0.001). This decline was significantly higher in patients receiving mineralocorticoid receptor antagonists at baseline (mean decline -22% of baseline value vs -3%, P=0.037). Mean serum creatinine concentration did not change significantly during follow-up and no creatinine-based renal function estimating equation was able to detect the significant longitudinal decline of renal function determined by iohexol clearance. After accounting for body composition, the accuracy of the equations improved, but not their ability to detect renal function decline. Renal function measured with iohexol plasma clearance showed relevant decline in CHF patients, particularly in those treated with mineralocorticoid receptor antagonists. None of the equations for renal function estimation was able to detect these changes. ClinicalTrials.gov registration number: NCT01829880.

  1. Automated monosegmented flow analyser. Determination of glucose, creatinine and urea.

    Science.gov (United States)

    Raimundo Júnior, I M; Pasquini, C

    1997-10-01

    An automated monosegmented flow analyser containing a sampling valve and a reagent addition module and employing a laboratory-made photodiode array spectrophotometer as detection system is described. The instrument was controlled by a 386SX IBM compatible microcomputer through an IC8255 parallel port that communicates with the interface which controls the sampling valve and reagent addition module. The spectrophotometer was controlled by the same microcomputer through an RS232 serial standard interface. The software for the instrument was written in QuickBasic 4.5. Opto-switches were employed to detect the air bubbles limiting the monosegment, allowing precise sample localisation for reagent addition and signal reading. The main characteristics of the analyser are low reagent consumption and high sensitivity which is independent of the sample volume. The instrument was designed to determine glucose, creatinine or urea in blood plasma and serum without hardware modification. The results were compared against those obtained by the Clinical Hospital of UNICAMP using commercial analysers. Correlation coefficients among the methods were 0.997, 0.982 and 0.996 for glucose, creatinine and urea, respectively.

  2. Quantification of carbamylated albumin in serum based on capillary electrophoresis.

    Science.gov (United States)

    Delanghe, Sigurd; Moerman, Alena; Pletinck, Anneleen; Schepers, Eva; Glorieux, Griet; Van Biesen, Wim; Delanghe, Joris R; Speeckaert, Marijn M

    2017-09-01

    Protein carbamylation, a nonenzymatic posttranslational modification promoted during uremia, is linked to a poor prognosis. In the present study, carbamylation of serum albumin was assayed using the symmetry factor on a capillary electrophoresis instrument (Helena V8). The symmetry factor has been defined as the distance from the center line of the peak to the back slope, divided by the distance from the center line of the peak to the front slope, with all measurements made at 10% of the maximum peak height. Serum albumin, creatinine, and urea concentrations were assayed using routine methods, whereas uremic toxins were determined using HPLC. In vitro carbamylation induced a marked albumin peak asymmetry. Reference values for the albumin symmetry factor were 0.69-0.92. In kidney patients, albumin peak asymmetry corresponded to the chronic kidney disease stage (p < 0.0001). The symmetry factor correlated well with serum urea (r = -0.5595, p < 0.0001) and creatinine (r = -0.5986, p < 0.0001) concentrations. Several protein-bound uremic toxins showed a significant negative correlation with the symmetry factor. Morphology of the albumin fraction was not affected by presence of glycated albumin and protein-bound antibiotics. In conclusion, the presented method provides a simple, practical way for monitoring protein carbamylation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Adherence to guidelines for creatinine and potassium monitoring and discontinuation following renin–angiotensin system blockade: a UK general practice-based cohort study

    Science.gov (United States)

    Schmidt, Morten; Bhaskaran, Krishnan; Nitsch, Dorothea; Sørensen, Henrik Toft; Smeeth, Liam; Tomlinson, Laurie A

    2017-01-01

    Objectives To examine adherence to serum creatinine and potassium monitoring and discontinuation guidelines following initiation of treatment with ACE inhibitors (ACEI) or angiotensin receptor blockers (ARBs); and whether high-risk patients are monitored. Design A general practice-based cohort study using electronic health records from the UK Clinical Practice Research Datalink and Hospital Episode Statistics. Setting UK primary care, 2004–2014. Subjects 223 814 new ACEI/ARB users. Main outcome measures Proportion of patients with renal function monitoring before and after ACEI/ARB initiation; creatinine increase ≥30% or potassium levels >6 mmol/L at first follow-up monitoring; and treatment discontinuation after such changes. Using logistic regression models, we also examined patient characteristics associated with these biochemical changes, and with follow-up monitoring within the guideline recommendation of 2 weeks after treatment initiation. Results 10% of patients had neither baseline nor follow-up monitoring of creatinine within 12 months before and 2 months after initiation of an ACEI/ARB, 28% had monitoring only at baseline, 15% only at follow-up, and 47% both at baseline and follow-up. The median period between the most recent baseline monitoring and drug initiation was 40 days (IQR 12–125 days). 34% of patients had baseline creatinine monitoring within 1 month before initiating therapy, but creatinine increase ≥30% (n=567, 1.2%) or potassium level >6 mmol/L (n=191, 0.4%), 80% continued treatment. Although patients with prior myocardial infarction, hypertension or baseline potassium >5 mmol/L were at high risk of ≥30% increase in creatinine after ACEI/ARB initiation, there was no evidence that they were more frequently monitored. Conclusions Only one-tenth of patients initiating ACEI/ARB therapy receive the guideline-recommended creatinine monitoring. Moreover, the vast majority of the patients fulfilling postinitiation

  4. False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.

    2015-01-01

    Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID

  5. GFR prediction from cystatin C and creatinine in children: body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    ) aged 2-14 years (mean 8.8 years). GFR was 14-147 mL/min/1.73m2 (mean 97 mL/min/1.73m2). BCM was estimated using bioimpedance spectroscopy (Xitron Hydra 4200). Log-transformed data on BCM/CysC, serum creatinine (SCr), body-surface-area (BSA), height x BSA/SCr, serum CysC, weight, sex, age, height, serum....... The present equation also had the highest R2 and the narrowest 95% limits of agreement. CONCLUSION: The new equation predicts GFR with higher accuracy than other equations. Endogenous methods are, however, still not accurate enough to replace exogenous markers when GFR must be determined with high accuracy...

  6. Paper-based Platform for Urinary Creatinine Detection.

    Science.gov (United States)

    Sittiwong, Jarinya; Unob, Fuangfa

    2016-01-01

    A new paper platform was developed for the colorimetric detection of creatinine. The filter paper was coated with 3-propylsulfonic acid trimethoxysilane and used as the platform. Creatinine in a cationic form was extracted onto the paper via an ion-exchange mechanism and detected through the Jaffé reaction, resulting in a yellow-orange color complex. The color change on the paper could be observed visually, and the quantitative detection of creatinine was achieved through monitoring the color intensity change. The color intensity of creatinine complexes on the paper platform as a function of the creatinine concentration provided a linear range for creatinine detection in the range of 10 - 60 mg L(-1) and a detection limit of 4.2 mg L(-1). The accuracy of the proposed paper-based method was comparable to the conventional standard Jaffé method. This paper platform could be applied for simple and rapid detection of creatinine in human urine samples with a low consumption of reagent.

  7. A meta-analysis of genome-wide data from five European isolates reveals an association of COL22A1, SYT1, and GABRR2 with serum creatinine level

    Directory of Open Access Journals (Sweden)

    Oostra Ben A

    2010-03-01

    Full Text Available Abstract Background Serum creatinine (SCR is the most important biomarker for a quick and non-invasive assessment of kidney function in population-based surveys. A substantial proportion of the inter-individual variability in SCR level is explicable by genetic factors. Methods We performed a meta-analysis of genome-wide association studies of SCR undertaken in five population isolates ('discovery cohorts', all of which are part of the European Special Population Network (EUROSPAN project. Genes showing the strongest evidence for an association with SCR (candidate loci were replicated in two additional population-based samples ('replication cohorts'. Results After the discovery meta-analysis, 29 loci were selected for replication. Association between SCR level and polymorphisms in the collagen type XXII alpha 1 (COL22A1 gene, on chromosome 8, and in the synaptotagmin-1 (SYT1 gene, on chromosome 12, were successfully replicated in the replication cohorts (p value = 1.0 × 10-6 and 1.7 × 10-4, respectively. Evidence of association was also found for polymorphisms in a locus including the gamma-aminobutyric acid receptor rho-2 (GABRR2 gene and the ubiquitin-conjugating enzyme E2-J1 (UBE2J1 gene (replication p value = 3.6 × 10-3. Previously reported findings, associating glomerular filtration rate with SNPs in the uromodulin (UMOD gene and in the schroom family member 3 (SCHROOM3 gene were also replicated. Conclusions While confirming earlier results, our study provides new insights in the understanding of the genetic basis of serum creatinine regulatory processes. In particular, the association with the genes SYT1 and GABRR2 corroborate previous findings that highlighted a possible role of the neurotransmitters GABAA receptors in the regulation of the glomerular basement membrane and a possible interaction between GABAAreceptors and synaptotagmin-I at the podocyte level.

  8. Reference intervals for serum cystatin C and creatinine of an ...

    African Journals Online (AJOL)

    2014-09-25

    Sep 25, 2014 ... Some studies suggest that GFR estimated from serum cystatin C (Cys C) is more accurate than ... Current clinical practice guidelines[1,2] recommend the use of ..... Source of Support: Nil, Conflict of Interest: None declared.

  9. Synthesis, Characterization and Biological Activities of Creatinine Amides and Creatinine Schiff Bases.

    Science.gov (United States)

    Mumtaz, Amara; Zahoor, Fareeha; Zaib, Sumera; Nawaz, Muhammad Azhar H; Saeed, Aamer; Waseem, Amir; Khan, Afsar; Hussain, Izhar; Iqbal, Jamshed

    2017-01-30

    In spite of substantial progress in scientific cognizance and medical technology, still infectious diseases are among the leading cause of morbidity and mortality. Creatinine and Schiff bases are well known for their diverse range of biological activities and thought to be emerging and useful therapeutic target for the treatment of several diseases. The present work was aimed to illustrate the influence of substitution of amides and Schiff bases on creatinine and their antimicrobial, antioxidant and anti-urease effectiveness was determined. Creatinine substituted amides (1-2) and creatinine Schiff bases (3-7) were synthesized and characterized by NMR and IR spectral data in combination with elemental analysis. All the compounds (1-7) were investigated on Jack bean urease for their urease inhibitory potential. Investigation of antimicrobial activity of the compounds was made by the agar dilution method. Moreover, 1,1-diphenyl-2- picrylhydrazyl (DPPH) method was used to determine their antioxidant potential. Molecular docking studies were also carried out to elucidate their relationship with the binding pockets of the enzyme. The compounds were found to be potent inhibitors of urease. The synthesized derivatives exhibited significant inhibition against Gram-positive and Gram-negative bacterial strains, as compared to standard, ciprofloxacin. Creatinine based derivatives exhibited potential antifungal activity when tested on infectious and pathogenic fungal strains. Similarly, most of the compounds exhibited good antioxidant activity. These derivatives may serve as a source of potential antioxidants and also help to retard microbial growth in food industry. Similarly, the studies provide a basis for further research to develop more potent urease inhibitory compounds of medicinal /agricultural interest. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  10. Assessment of 1H NMR-based metabolomics analysis for normalization of urinary metals against creatinine.

    Science.gov (United States)

    Cassiède, Marc; Nair, Sindhu; Dueck, Meghan; Mino, James; McKay, Ryan; Mercier, Pascal; Quémerais, Bernadette; Lacy, Paige

    2017-01-01

    Proton nuclear magnetic resonance ( 1 H NMR, or NMR) spectroscopy and inductively coupled plasma-mass spectrometry (ICP-MS) are commonly used for metabolomics and metal analysis in urine samples. However, creatinine quantification by NMR for the purpose of normalization of urinary metals has not been validated. We assessed the validity of using NMR analysis for creatinine quantification in human urine samples in order to allow normalization of urinary metal concentrations. NMR and ICP-MS techniques were used to measure metabolite and metal concentrations in urine samples from 10 healthy subjects. For metabolite analysis, two magnetic field strengths (600 and 700MHz) were utilized. In addition, creatinine concentrations were determined by using the Jaffe method. Creatinine levels were strongly correlated (R 2 =0.99) between NMR and Jaffe methods. The NMR spectra were deconvoluted with a target database containing 151 metabolites that are present in urine. A total of 50 metabolites showed good correlation (R 2 =0.7-1.0) at 600 and 700MHz. Metal concentrations determined after NMR-measured creatinine normalization were comparable to previous reports. NMR analysis provided robust urinary creatinine quantification, and was sufficient for normalization of urinary metal concentrations. We found that NMR-measured creatinine-normalized urinary metal concentrations in our control subjects were similar to general population levels in Canada and the United Kingdom. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Phosphate, urea and creatinine clearances: haemodialysis adequacy assessed by weekly monitoring.

    Science.gov (United States)

    Debowska, Malgorzata; Wojcik-Zaluska, Alicja; Ksiazek, Andrzej; Zaluska, Wojciech; Waniewski, Jacek

    2015-01-01

    The specific distribution of phosphate and the control mechanisms for its plasma level makes phosphate kinetics during haemodialysis (HD) considerably different from those of urea and creatinine and makes the quantitative evaluation of adequacy of phosphate removal difficult. We propose the application of equivalent continuous clearance (ECC) as a phosphate adequacy parameter and compare it with ECC for creatinine and urea. Three consecutive dialysis sessions were evaluated for 25 patients on maintenance HD. Concentrations of phosphate, urea and creatinine in plasma were measured every 1h during the treatment and 45 min after, and every 30 min in dialysate. ECC was calculated using the removed solute mass assessed in dialysate and weekly solute profile in plasma. Similar calculations were performed also for the midweek dialysis session only. Different versions of the reference concentration for ECC were applied. ECC with peak average reference concentration was 5.4 ± 1.0 for phosphate, 7.0 ± 1.0 for urea and 4.7 ± 1.0 mL/min for creatinine. ECC for urea and creatinine were well correlated in contrast to the correlations of ECC for phosphate versus urea and creatinine. Midweek ECC were higher than weekly ECC, but they were well correlated for urea and creatinine, but only weakly for phosphate. HD adequacy monitoring for phosphate may be performed using ECC, but it is less predictable than similar indices for urea and creatinine. The values of ECC for phosphate are within the range expected for its molecular size compared with those for urea and creatinine. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  12. Evaluation of urinary 3-methylhistidine excretion in infection by measurements of 1-methylhistidine and the creatinine ratios

    DEFF Research Database (Denmark)

    Sjölin, J; Stjernström, H; Henneberg, S

    1989-01-01

    as an indicator of meat intake. We studied the basal urinary excretion of 1MH and whether this was influenced by infection and we compared the use of 3MH vs the 3MH:creatinine ratio (3MH:Cr) in detecting changes during infection. The basal excretion of 1MH was 84.9 mumol/24 h and its creatinine molar ratio (1MH...... with only 4 in 3MH. This was due to a higher precision in 3MH:Cr despite the concomitant significant increase in urinary creatinine excretion....

  13. Clinical utility of spot urine protein-to-creatinine ratio modified by estimated daily creatinine excretion in children.

    Science.gov (United States)

    Yang, Eun Mi; Yoon, Bo Ae; Kim, Soo Wan; Kim, Chan Jong

    2017-06-01

    The spot urine protein-to-creatinine ratio (UPCR) is widely used to predict 24-h urine protein (24-h UP) excretion. In patients with low daily urine creatinine excretion (UCr), however, the UPCR may overestimate 24-h UP. The aim of this study was to predict 24-h UP using UPCR adjusted by estimated 24-h UCr in children. This study included 442 children whose 24-h UP and spot UPCR were measured concomitantly. Estimated 24-h UCr was calculated using three previously existing equations. We estimated the 24-h UP excretion from UPCR by multiplying the estimated UCr. The results were compared with the measured 24-h UP. There was a strong correlation between UPCR and 24-h UP (r = 0.801, P < 0.001), and the correlation improved after multiplying the UPCR by the measured UCr (r = 0.847, P < 0.001). Using the estimated UCr rather than the measured UCr, there was high accuracy and strong correlation between the estimated UPCR weighted by the Cockcroft-Gault equation and 24-h UP. Improvement was also observed in the subgroup (proteinuria vs. non-proteinuria) analysis, particularly in the proteinuria group. The spot UPCR multiplied by the estimated UCr improved the accuracy of prediction of the 24-h UP in children.

  14. Creatinine Deiminase Adsorption onto Silicalite-Modified pH-FET for Creation of New Creatinine-Sensitive Biosensor

    OpenAIRE

    Marchenko, Svitlana V.; Soldatkin, Oleksandr O.; Kasap, Berna Ozansoy; Kurc, Burcu Akata; Soldatkin, Alexei P.; Dzyadevych, Sergei V.

    2016-01-01

    In the work, silicalite particles were used for the surface modification of pH-sensitive field-effect transistors (pH-FETs) with the purpose of developing new creatinine-sensitive biosensor. Creatinine deiminase (CD) adsorbed on the surface of silicalite-coated pH-FET served as a bioselective membrane. The biosensor based on CD immobilized in glutaraldehyde vapor (GA) was taken as control. The creatinine-sensitive biosensor obtained by adsorption on silicalite was shown to have better analyti...

  15. Creatinine metabolism in Cryptococcus neoformans and Cryptococcus bacillisporus.

    OpenAIRE

    Polacheck, I; Kwon-Chung, K J

    1980-01-01

    The pathogenic species of Cryptococcus, C. neoformans and C. bacillisporus, utilized creatinine as a source of nitrogen but not of carbon. Chromatographic and autoradiographic studies suggest that creatinine metabolism in both species involves a single step resulting in the production of methylhydantoin and ammonia. The enzyme responsible for this step, creatinine deiminase, was produced by the cells only in the presence of creatinine in both species. The synthesis of creatinine deiminase was...

  16. Reference intervals for selected serum biochemistry analytes in cheetahs (Acinonyx jubatus

    Directory of Open Access Journals (Sweden)

    Gavin C. Hudson-Lamb

    2016-02-01

    Full Text Available Published haematologic and serum biochemistry reference intervals are very scarce for captive cheetahs and even more for free-ranging cheetahs. The current study was performed to establish reference intervals for selected serum biochemistry analytes in cheetahs. Baseline serum biochemistry analytes were analysed from 66 healthy Namibian cheetahs. Samples were collected from 30 captive cheetahs at the AfriCat Foundation and 36 free-ranging cheetahs from central Namibia. The effects of captivity-status, age, sex and haemolysis score on the tested serum analytes were investigated. The biochemistry analytes that were measured were sodium, potassium, magnesium, chloride, urea and creatinine. The 90% confidence interval of the reference limits was obtained using the non-parametric bootstrap method. Reference intervals were preferentially determined by the non-parametric method and were as follows: sodium (128 mmol/L – 166 mmol/L, potassium (3.9 mmol/L – 5.2 mmol/L, magnesium (0.8 mmol/L – 1.2 mmol/L, chloride (97 mmol/L – 130 mmol/L, urea (8.2 mmol/L – 25.1 mmol/L and creatinine (88 µmol/L – 288 µmol/L. Reference intervals from the current study were compared with International Species Information System values for cheetahs and found to be narrower. Moreover, age, sex and haemolysis score had no significant effect on the serum analytes in this study. Separate reference intervals for captive and free-ranging cheetahs were also determined. Captive cheetahs had higher urea values, most likely due to dietary factors. This study is the first to establish reference intervals for serum biochemistry analytes in cheetahs according to international guidelines. These results can be used for future health and disease assessments in both captive and free-ranging cheetahs.

  17. A comparison of observed versus estimated baseline creatinine for determination of RIFLE class in patients with acute kidney injury

    NARCIS (Netherlands)

    Bagshaw, Sean M.; Uchino, Shigehiko; Cruz, Dinna; Bellomo, Rinaldo; Morimatsu, Hiroshi; Morgera, Stanislao; Schetz, Miet; Tan, Ian; Bouman, Catherine; Macedo, Etienne; Gibney, Noel; Tolwani, Ashita; Oudemans-van Straaten, Heleen M.; Ronco, Claudio; Kellum, John A.; French, Craig; Mulder, John; Pinder, Mary; Roberts, Brigit; Botha, John; Mudholkar, Pradeen; Holt, Andrew; Hunt, Tamara; Honoré, Patrick Maurice; Clerbaux, Gaetan; Schetz, Miet Maria; Wilmer, Alexander; Yu, Luis; Macedo, Ettiene V.; Laranja, Sandra Maria; Rodrigues, Cassio José; Suassuna, José Hermógenes Rocco; Ruzany, Frederico; Campos, Bruno; Leblanc, Martine; Senécal, Lynne; Gibney, R. T. Noel; Johnston, Curtis; Brindley, Peter; Tan, Ian K. S.; Chen, Hui De; Wan, Li; Rokyta, Richard; Krouzecky, Ales; Neumayer, Hans-Helmut; Detlef, Kindgen-Milles; Mueller, Eckhard; Tsiora, Vicky; Sombolos, Kostas; Mustafa, Iqbal; Suranadi, Iwayan; Bar-Lavie, Yaron; Nakhoul, Farid; Ceriani, Roberto; Bortone, Franco; Zamperetti, Nereo; Pappalardo, Federico; Marino, Giovanni; Calabrese, Prospero; Monaco, Francesco; Liverani, Chiara; Clementi, Stefano; Coltrinari, Rosanna; Marini, Benedetto; Fuke, Nobuo; Miyazawa, Masaaki; Katayama, Hiroshi; Kurasako, Toshiaki; Hirasawa, Hiroyuki; Oda, Shigeto; Tanigawa, Koichi; Tanaka, Keiichi; Oudemans-van Straaten, Helena Maria; de Pont, Anne-Cornelie J. M.; Bugge, Jan Frederik; Riddervold, Fridtjov; Nilsen, Paul Age; Julsrud, Joar; Teixeira e Costa, Fernando; Marcelino, Paulo; Serra, Isabel Maria; Yaroustovsky, Mike; Grigoriyanc, Rachik; Lee, Kang Hoe; Loo, Shi; Singh, Kulgit; Barrachina, Ferran; Llorens, Julio; Sanchez-Izquierdo-Riera, Jose Angel; Toral-Vazquez, Darío; Wizelius, Ivar; Hermansson, Dan; Gaspert, Tomislav; Maggiorini, Marco; Davenport, Andrew; Lombardi, Raúl; Llopart, Teresita; Venkataraman, Ramesh; Kellum, John; Murray, Patrick; Trevino, Sharon; Benjamin, Ernest; Hufanda, Jerry; Paganini, Emil; Warnock, David; Guirguis, Nabil

    2009-01-01

    The RIFLE classification scheme for acute kidney injury (AKI) is based on relative changes in serum creatinine (SCr) and on urine output. The SCr criteria, therefore, require a pre-morbid baseline value. When unknown, current recommendations are to estimate a baseline SCr by the MDRD equation.

  18. Relation between creatinine and uric acid excretion.

    OpenAIRE

    Nishida, Y

    1992-01-01

    The relation between creatinine and uric acid metabolism was analysed in 77 male patients with primary gout and 62 healthy male subjects. Significant positive correlations between 24 hour urinary creatinine and uric acid excretion were shown in both groups. The mean urinary creatinine and uric acid excretions in the patients with gout were significantly increased as compared with those of normal male controls. These results suggest that there is a close correlation between creatinine and uric...

  19. Ultrasonographically determined renal values and comparisons to serum biochemistry renal variables in aged semi-captive cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Kirberger, Robert M; Tordiffe, Adrian S W

    2017-11-06

    Cheetahs in captivity have a high prevalence of chronic renal diseases. We ultrasonographically evaluated the renal volumes, a variety of renal dimensions, interarcuate artery resistive indices (RI) as well as aortic diameters and the length of the ventral aspect of the 6th lumbar vertebrae in 27 aged semi-captive anesthetized cheetahs. Renal size, dimensions and ratios were compared to urine specific gravity, serum creatinine and urea values. There were minimal differences for all values between left and right kidneys. Mean kidney length was 65.1 mm (range 55.2-76.9) with left kidney length ratios to L6 length being 1.60 (range 1.27-2.06) and to the aortic diameter 7.69 (range 4.54-10.72). Significant correlations between left renal length as well as length:L6 ratio to creatinine values were found ((r - 0.66) and (r - 0.60) respectively). The mean RI values of the different sedation/anesthetic protocols ranged from 0.46-0.55. Left renal length and L6 ventral vertebral body length as well as left kidney RI values should be routinely measured in all cheetah abdominal ultrasound examinations. These measurements, together with serum creatinine, urea and urine specific gravity values may be relatively sensitive indicators of early renal pathology in the absence of gross ultrasonographic changes.

  20. Iohexol clearance is superior to creatinine-based renal function estimating equations in detecting short-term renal function decline in chronic heart failure

    Science.gov (United States)

    Cvan Trobec, Katja; Kerec Kos, Mojca; von Haehling, Stephan; Anker, Stefan D.; Macdougall, Iain C.; Ponikowski, Piotr; Lainscak, Mitja

    2015-01-01

    Aim To compare the performance of iohexol plasma clearance and creatinine-based renal function estimating equations in monitoring longitudinal renal function changes in chronic heart failure (CHF) patients, and to assess the effects of body composition on the equation performance. Methods Iohexol plasma clearance was measured in 43 CHF patients at baseline and after at least 6 months. Simultaneously, renal function was estimated with five creatinine-based equations (four- and six-variable Modification of Diet in Renal Disease, Cockcroft-Gault, Cockcroft-Gault adjusted for lean body mass, Chronic Kidney Disease Epidemiology Collaboration equation) and body composition was assessed using bioimpedance and dual-energy x-ray absorptiometry. Results Over a median follow-up of 7.5 months (range 6-17 months), iohexol clearance significantly declined (52.8 vs 44.4 mL/[min ×1.73 m2], P = 0.001). This decline was significantly higher in patients receiving mineralocorticoid receptor antagonists at baseline (mean decline -22% of baseline value vs -3%, P = 0.037). Mean serum creatinine concentration did not change significantly during follow-up and no creatinine-based renal function estimating equation was able to detect the significant longitudinal decline of renal function determined by iohexol clearance. After accounting for body composition, the accuracy of the equations improved, but not their ability to detect renal function decline. Conclusions Renal function measured with iohexol plasma clearance showed relevant decline in CHF patients, particularly in those treated with mineralocorticoid receptor antagonists. None of the equations for renal function estimation was able to detect these changes. ClinicalTrials.gov registration number NCT01829880 PMID:26718759

  1. A comparison of creatinine concentration with 40K radioactivity in spot urine

    International Nuclear Information System (INIS)

    Yoo, Jaeryong; Park, Minjeong; Park, Seyoung; Ha, Wiho; Lee, Seungsook; Kim, Kwangpyo; Yoo, Jaeryong; Park, Minjeong

    2013-01-01

    24 hour urine collection is technically difficult to carry out and inconvenience for subjects. Also the result of 24 hour urine may vary from collection date. The spot urine assessment has large uncertainty that some spot urine concentrated or some spot urine diluted. Hence, it needs to apply normalization method for minimizing result of measurement the spot urine. In radiation emergency, specific gravity method was proposed which method use portable density meter for measuring density of urine and then normalization. The creatinine test recommend by ICRP (1968) and IAEA (1999) is the most common method for urine normalization. However, the creatinine result was various which depends upon sex, age, race and health conditions. Thus it needs to supplementary method for urine normalization. Natural potassium has isotopes those are K-39, K-40, and K-41, in the percentages of 93.08, 0.0118 and 6.91, respectively. Especially, the K-40 emits relatively high energy (1.46 MeV gamma ray) with a half life of 1.248 Χ 10 9 γ. The potassium is an essential element in human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human body contains specific amount of the potassium and then excreted regularly. And then K-40 is measurable in urine sample using HPGs detector. The purpose of this study is to estimate the variability of spot urine normalization method for assessing the internal exposure dose of hospital workers who work related with radiopharmaceutical produce. The use of creatinine as normalization of spot urine samples for internal dosimetry is possible to reduce level of uncertainty. However, creatinine range is wide which means the creatinine is not exactly correct reference value for normalization. Or some malfunction in creatinine analysis, it need to another supplementary method for normalization for adequately assessing the activity in spot urine samples. In this study

  2. Pemberian diet ekstra formula komersial dan diet ekstra filtrat ikan gabus intradialisis serta pengaruhnya terhadap kadar serum albumin dan kreatinin pasien dengan hemodialisis di RSU Dr. Saiful Anwar Malang

    Directory of Open Access Journals (Sweden)

    Etik Sulistyowati

    2008-11-01

    Conclusion: There was significant effect of the supply of commercial formula and local catfish filtrate extra diet to increase of albumin serum level of the subject and there was no significant effect of the supply of extra diet to creatinine serum level; however, the supply of local catfish filtrate extra diet could maintain creatinine serum level.

  3. The diagnostic value of both troponin T and creatinine kinase isoenzyme (CK-MB in detecting combined renal and myocardial injuries in asphyxiated infants.

    Directory of Open Access Journals (Sweden)

    Wilson E Sadoh

    Full Text Available Troponin T (cTnT and Creatinine Kinase Isoenzyme (CK-MB are both markers of myocardial injuries. However, CK-MB is also elevated in acute kidney injury.The diagnostic value of both cTnT and cardiac CK-MB in combined myocardial and acute kidney injuries (AKI in asphyxiated neonates was evaluated.40 asphyxiated infants and 40 non-asphyxiated controls were consecutively recruited. Serum levels of cTnT, CK-MB and creatinine were measured. Myocardial injury and AKI were defined as cTnT >95th percentile of the control and serum creatinine >1.0 mg/dl respectively.Of the 40 subjects, 9 (22.50%, 8 (20.00% and 4 (10.00% had myocardial injury, AKI and combined AKI and myocardial injuries respectively. The mean cTnT and CK-MB values were highest in infants with combined AKI and myocardial injuries. The Mean cTnT in infants with AKI, myocardial injury and combined AKI and myocardial injuries were 0.010±0.0007 ng/ml, 0.067±0.040 ng/ml and 0.084±0.067 ng/ml respectively, p = 0.006. The mean CK-MB in infants with AKI, myocardial injury and combined AKI and myocardial injuries were 2.78±0.22 ng/ml, 1.28±0.11 ng/ml and 4.58±0.52 ng/ml respectively, p = <0.0001.In severe perinatal asphyxia, renal and myocardial injuries could co-exist. Elevated cTnT signifies the presence of myocardial injury. Elevated CK-MB indicates either myocardial injury, AKI or both. Therefore renal injury should be excluded in asphyxiated infants with elevated CK-MB.

  4. Serum cardiac troponin I in canine syncope and seizures.

    Science.gov (United States)

    Dutton, E; Dukes-McEwan, J; Cripps, P J

    2017-02-01

    To determine if serum cardiac troponin I (cTnI) concentration distinguishes between cardiogenic syncope and collapsing dogs presenting with either generalized epileptic seizures (both with and without cardiac disease) or vasovagal syncope. Seventy-nine prospectively recruited dogs, grouped according to aetiology of collapse: generalized epileptic seizures (group E), cardiogenic syncope (group C), dogs with both epileptic seizures and cardiac disease (group B), vasovagal syncope (group V) or unclassified (group U). Most patients had ECG (n = 78), echocardiography (n = 78) and BP measurement (n = 74) performed. Dogs with a history of intoxications, trauma, evidence of metabolic disorders or renal insufficiency (based on serum creatinine concentrations >150 μmol/L and urine specific gravity disease) or vasovagal syncope. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Higher body mass index is associated with higher fractional creatinine excretion in healthy subjects

    NARCIS (Netherlands)

    Sinkeler, Steef J.; Visser, Folkert W.; Krikken, Jan A.; Stegeman, Coen A.; Homan van der Heide, Jaap J.; Navis, Gerjan

    2011-01-01

    Accurate glomerular filtration rate (GFR) measurement in normal to high range is important for epidemiological studies and workup for kidney donation. Creatinine-based equations perform poorly in this GFR range. Creatinine clearance (CrCl) provides a substitute, provided urine is collected

  6. Higher body mass index is associated with higher fractional creatinine excretion in healthy subjects

    NARCIS (Netherlands)

    Sinkeler, Steef J.; Visser, Folkert W.; Krikken, Jan A.; Stegeman, Coen A.; van der Heide, Jaap J. Homan; Navis, Gerjan

    2011-01-01

    Background. Accurate glomerular filtration rate (GFR) measurement in normal to high range is important for epidemiological studies and workup for kidney donation. Creatinine-based equations perform poorly in this GFR range. Creatinine clearance (CrCl) provides a substitute, provided urine is

  7. Serum Creatinine Distinguishes Duchenne Muscular Dystrophy from Becker Muscular Dystrophy in Patients Aged ≤3 Years: A Retrospective Study.

    Science.gov (United States)

    Wang, Liang; Chen, Menglong; He, Ruojie; Sun, Yiming; Yang, Juan; Xiao, Lulu; Cao, Jiqing; Zhang, Huili; Zhang, Cheng

    2017-01-01

    Here, we investigated correlations between serum creatinine (SCRN) levels and clinical phenotypes of dystrophinopathy in young patients. Sixty-eight patients with dystrophinopathy at the Neuromuscular Clinic, The First Affiliated Hospital, Sun Yat-sen University, were selected for this study. The diagnosis of dystrophinopathy was based on clinical manifestation, biochemical changes, and molecular analysis. Some patients underwent muscle biopsies; SCRN levels were tested when patients were ≤3 years old, and reading frame changes were analyzed. Each patient was followed up, and motor function and clinical phenotype were assessed when the same patients were ≥4 years old. Our findings indicated that in young patients, lower SCRN levels were associated with increased disease severity ( p  Becker muscular dystrophy (BMD) ( p  dystrophy (DMD) ( p  < 0.01) and were significantly higher in patients carrying in-frame mutations than in patients carrying out-of-frame mutations ( p  < 0.001). SCRN level cutoff values for identifying mild BMD [18 µmol/L; area under the curve (AUC): 0.947; p  < 0.001] and DMD (17 µmol/L; AUC: 0.837; p  < 0.001) were established. These results suggest that SCRN might be a valuable biomarker for distinguishing DMD from BMD in patients aged ≤3 years and could assist in the selection of appropriate treatment strategies.

  8. Preliminary Studies on Some Haematological and Serum ...

    African Journals Online (AJOL)

    The mean serum values of sodium, potassium, chloride and bicarbonate, as well as urea, creatinine and alanine aminotransferase(ALT) enzyme did not differ from the normal values, while the mean aspartate aminotransferase (AST) enzyme value appeared to be lower than the normal range.In conclusion, the RBC, PCV ...

  9. Influence of Urine Creatinine on the Relationship between the Albumin-to-Creatinine Ratio and Cardiovascular Events

    Science.gov (United States)

    Carter, Caitlin E.; Gansevoort, Ronald T.; Scheven, Lieneke; Heerspink, Hiddo J. Lambers; Shlipak, Michael G.; de Jong, Paul E.

    2012-01-01

    Summary Background and objectives In the albumin-to-creatinine ratio (spot-ACR), urine creatinine corrects for tonicity but also reflects muscle mass. Low muscle mass is associated with cardiovascular disease (CVD). We hypothesized that the spot-ACR would be higher in women, lower-weight persons, and older individuals, independent of timed urine albumin excretion (24hr-UAE), and accordingly, that spot-ACR would be more strongly associated with CVD events than 24hr-UAE in these subgroups. Design, setting, participants, & methods 2627 PREVEND (Prevention of Renal and Vascular End-stage Disease) participants with 24hr-UAE creatinine concentration (HR, 1.16 per ln-SD higher) were associated with CVD events. Spot-ACR was more strongly associated with CVD events than either component of the ratio (HR, 1.41 per ln-SD higher). Associations of spot-ACR ≥10 mg/g versus less (HR, 2.33) and 24hr-UAE ≥10 mg/d versus less (HR, 2.09) with CVD events were similar, and there were no significant differences across subgroups (P for interactions >0.06). Conclusions In community-living individuals with 24hr-UAE creatinine is associated with CVD risk, but high urine albumin is a stronger determinant of the association of spot-ACR with CVD than is low urine creatinine. PMID:22383750

  10. Sensitivity and specificity of a single emergency department measurement of urinary neutrophil gelatinase-associated lipocalin for diagnosing acute kidney injury.

    Science.gov (United States)

    Nickolas, Thomas L; O'Rourke, Matthew J; Yang, Jun; Sise, Meghan E; Canetta, Pietro A; Barasch, Nicholas; Buchen, Charles; Khan, Faris; Mori, Kiyoshi; Giglio, James; Devarajan, Prasad; Barasch, Jonathan

    2008-06-03

    A single serum creatinine measurement cannot distinguish acute kidney injury from chronic kidney disease or prerenal azotemia. To test the sensitivity and specificity of a single measurement of urinary neutrophil gelatinase-associated lipocalin (NGAL) and other urinary proteins to detect acute kidney injury in a spectrum of patients. Prospective cohort study. Emergency department of Columbia University Medical Center, New York, New York. 635 patients admitted to the hospital with acute kidney injury, prerenal azotemia, chronic kidney disease, or normal kidney function. Diagnosis of acute kidney injury was based on the RIFLE (risk, injury, failure, loss, and end-stage) criteria and assigned by researchers who were blinded to experimental measurements. Urinary NGAL was measured by immunoblot, N-acetyl-beta-d-glucosaminidase (NAG) by enzyme measurement, alpha1-microglobulin and alpha(1)-acid glycoprotein by immunonephelometry, and serum creatinine by Jaffe kinetic reaction. Experimental measurements were not available to treating physicians. Patients with acute kidney injury had a significantly elevated mean urinary NGAL level compared with the other kidney function groups (416 microg/g creatinine [SD, 387]; P = 0.001). At a cutoff value of 130 microg/g creatinine, sensitivity and specificity of NGAL for detecting acute injury were 0.900 (95% CI, 0.73 to 0.98) and 0.995 (CI, 0.990 to 1.00), respectively, and positive and negative likelihood ratios were 181.5 (CI, 58.33 to 564.71) and 0.10 (CI, 0.03 to 0.29); these values were superior to those for NAG, alpha1-microglobulin, alpha1-acid glycoprotein, fractional excretion of sodium, and serum creatinine. In multiple logistic regression, urinary NGAL level was highly predictive of clinical outcomes, including nephrology consultation, dialysis, and admission to the intensive care unit (odds ratio, 24.71 [CI, 7.69 to 79.42]). All patients came from a single center. Few kidney biopsies were performed. A single measurement

  11. Decrease in Urinary Creatinine Excretion in Early Stage Chronic Kidney Disease

    Science.gov (United States)

    Tynkevich, Elena; Flamant, Martin; Haymann, Jean-Philippe; Metzger, Marie; Thervet, Eric; Boffa, Jean-Jacques; Vrtovsnik, François; Houillier, Pascal; Froissart, Marc; Stengel, Bénédicte

    2014-01-01

    Background Little is known about muscle mass loss in early stage chronic kidney disease (CKD). We used 24-hour urinary creatinine excretion rate to assess determinants of muscle mass and its evolution with kidney function decline. We also described the range of urinary creatinine concentration in this population. Methods We included 1072 men and 537 women with non-dialysis CKD stages 1 to 5, all of them with repeated measurements of glomerular filtration rate (mGFR) by 51Cr-EDTA renal clearance and several nutritional markers. In those with stage 1 to 4 at baseline, we used a mixed model to study factors associated with urinary creatinine excretion rate and its change over time. Results Baseline mean urinary creatinine excretion decreased from 15.3±3.1 to 12.1±3.3 mmol/24 h (0.20±0.03 to 0.15±0.04 mmol/kg/24 h) in men, with mGFR falling from ≥60 to creatinine excretion at baseline. Mean annual decline in mGFR was 1.53±0.12 mL/min/1.73 m2 per year and that of urinary creatinine excretion rate, 0.28±0.02 mmol/24 h per year. Patients with fast annual decline in mGFR of 5 mL/min/1.73 m2 had a decrease in urinary creatinine excretion more than twice as big as in those with stable mGFR, independent of changes in urinary urea as well as of other determinants of low muscle mass. Conclusions Decrease in 24-hour urinary creatinine excretion rate may appear early in CKD patients, and is greater the more mGFR declines independent of lowering protein intake assessed by 24-hour urinary urea. Normalizing urine analytes for creatininuria may overestimate their concentration in patients with reduced kidney function and low muscle mass. PMID:25401694

  12. Creatinine-Based and Cystatin C-Based GFR Estimating Equations and Their Non-GFR Determinants in Kidney Transplant Recipients.

    Science.gov (United States)

    Keddis, Mira T; Amer, Hatem; Voskoboev, Nikolay; Kremers, Walter K; Rule, Andrew D; Lieske, John C

    2016-09-07

    eGFR equations have been evaluated in kidney transplant recipients with variable performance. We assessed the performance of the Modification of Diet in Renal Disease equation and the Chronic Kidney Disease Epidemiology Collaboration equations on the basis of creatinine, cystatin C, and both (eGFR creatinine-cystatin C) compared with measured GFR by iothalamate clearance and evaluated their non-GFR determinants and associations across 15 cardiovascular risk factors. A cross-sectional cohort of 1139 kidney transplant recipients >1 year after transplant was analyzed. eGFR bias, precision, and accuracy (percentage of estimates within 30% of measured GFR) were assessed. Interaction of each cardiovascular risk factor with eGFR relative to measured GFR was determined. Median measured GFR was 55.0 ml/min per 1.73 m(2). eGFR creatinine overestimated measured GFR by 3.1% (percentage of estimates within 30% of measured GFR of 80.4%), and eGFR Modification of Diet in Renal Disease underestimated measured GFR by 2.2% (percentage of estimates within 30% of measured GFR of 80.4%). eGFR cystatin C underestimated measured GFR by -13.7% (percentage of estimates within 30% of measured GFR of 77.1%), and eGFR creatinine-cystatin C underestimated measured GFR by -8.1% (percentage of estimates within 30% of measured GFR of 86.5%). Lower measured GFR associated with older age, women, obesity, longer time after transplant, lower HDL, lower hemoglobin, lower albumin, higher triglycerides, higher proteinuria, and an elevated cardiac troponin T level but did not associate with diabetes, smoking, cardiovascular events, pretransplant dialysis, or hemoglobin A1c. These risk factor associations differed for five risk factors with eGFR creatinine, six risk factors for eGFR Modification of Diet in Renal Disease, ten risk factors for eGFR cystatin C, and four risk factors for eGFR creatinine-cystatin C. Thus, eGFR creatinine and eGFR creatinine-cystatin C are preferred over eGFR cystatin C in

  13. A comparison of creatinine concentration with {sup 40}K radioactivity in spot urine

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jaeryong; Park, Minjeong; Park, Seyoung; Ha, Wiho; Lee, Seungsook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Kim, Kwangpyo; Yoo, Jaeryong; Park, Minjeong [Kyung Hee Univ., Yongin (Korea, Republic of)

    2013-05-15

    24 hour urine collection is technically difficult to carry out and inconvenience for subjects. Also the result of 24 hour urine may vary from collection date. The spot urine assessment has large uncertainty that some spot urine concentrated or some spot urine diluted. Hence, it needs to apply normalization method for minimizing result of measurement the spot urine. In radiation emergency, specific gravity method was proposed which method use portable density meter for measuring density of urine and then normalization. The creatinine test recommend by ICRP (1968) and IAEA (1999) is the most common method for urine normalization. However, the creatinine result was various which depends upon sex, age, race and health conditions. Thus it needs to supplementary method for urine normalization. Natural potassium has isotopes those are K-39, K-40, and K-41, in the percentages of 93.08, 0.0118 and 6.91, respectively. Especially, the K-40 emits relatively high energy (1.46 MeV gamma ray) with a half life of 1.248 Χ 10{sup 9}γ. The potassium is an essential element in human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human which works as homeostatic regulation. Thus human body contains specific amount of the potassium and then excreted regularly. And then K-40 is measurable in urine sample using HPGs detector. The purpose of this study is to estimate the variability of spot urine normalization method for assessing the internal exposure dose of hospital workers who work related with radiopharmaceutical produce. The use of creatinine as normalization of spot urine samples for internal dosimetry is possible to reduce level of uncertainty. However, creatinine range is wide which means the creatinine is not exactly correct reference value for normalization. Or some malfunction in creatinine analysis, it need to another supplementary method for normalization for adequately assessing the activity in spot urine samples. In this

  14. Biochemical indicators of nephrotoxicity in blood serum of rats treated with novel 4-thiazolidinone derivatives or their complexes with polyethylene glycol-containing nanoscale polymeric carrier

    Directory of Open Access Journals (Sweden)

    L. I. Kоbylinska

    2016-02-01

    Full Text Available The aim of this study was to compare the effect of new synthetic 4-thiazolidinone derivatives (potential anticancer compounds denoted as 3882, 3288 and 3833 and doxorubicin (positive control in free form and in their complexes with synthetic polyethylene glycol-containing nanoscale polymeric carrier on the biochemical indicators of nephrotoxicity in blood serum of rats. The concentration of total protein, urea, creatinine, glucose, ions of sodium, potassium, calcium, iron and chloride was measured. It was found that after injection of the investigated compounds, the concentration of sodium cations and chloride anions in blood serum was increased compared with control (untreated animals. Doxorubicin’s injection was accompanied by a decrease in the concentration of iron cations. The concentration of total protein, urea and creatinine decreased under the influence of the studied compounds. Complexation of these аntineoplastic substances with a synthetic polymeric nanocarrier lowered the concentration of the investigated metabolites substantially compared to the effect of these compounds in free form. The normalization of concentration of total protein, urea and creatinine in blood serum of rats treated with complexes of the studied compounds with the polymeric carrier comparing with increased concentration of these indicators at the introduction of such compounds in free form was found.

  15. Recognition and Sensing of Creatinine.

    Science.gov (United States)

    Guinovart, Tomàs; Hernández-Alonso, Daniel; Adriaenssens, Louis; Blondeau, Pascal; Martínez-Belmonte, Marta; Rius, F Xavier; Andrade, Francisco J; Ballester, Pablo

    2016-02-12

    Current methods for creatinine quantification suffer from significant drawbacks when aiming to combine accuracy, simplicity, and affordability. Here, an unprecedented synthetic receptor, an aryl-substituted calix[4]pyrrole with a monophosphonate bridge, is reported that displays remarkable affinity for creatinine and the creatininium cation. The receptor works by including the guest in its deep and polar aromatic cavity and establishing directional interactions in three dimensions. When incorporated into a suitable polymeric membrane, this molecule acts as an ionophore. A highly sensitive and selective potentiometric sensor suitable for the determination of creatinine levels in biological fluids, such as urine or plasma, in an accurate, fast, simple, and cost-effective way has thus been developed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Glomerular filtration rate estimation from plasma creatinine after inhibition of tubular secretion: relevance of the creatinine assay

    NARCIS (Netherlands)

    Kemperman, F. A.; Silberbusch, J.; Slaats, E. H.; van Zanten, A. P.; Weber, J. A.; Krediet, R. T.; Arisz, L.

    1999-01-01

    BACKGROUND: Estimation of glomerular filtration rate (GFR) from plasma creatinine concentration after inhibition of tubular creatinine secretion with cimetidine provides a good assessment in patients with various nephropathies and with non-insulin-dependent diabetes mellitus (NIDDM). The aim of this

  17. Ethnicity is important for creatinine excretion among Inuit and Caucasians in Greenland.

    Science.gov (United States)

    Andersen, Stig; Dehnfeld, Marie; Laurberg, Peter

    2015-01-01

    Human nutrition, contamination and renal function are commonly assessed by the analysis of urine. A complete 24-hour urine sample is the ideal but it is inconvenient and unreliable. Thus, spot urine sampling with creatinine adjustment is widely used. Stratification for age and gender is recommended. Still, ethnicity may influence creatinine excretion. We collected 104 24-h urine samples among Inuit and non-Inuit living in Greenland. Completeness of sampling was checked by using para-amino benzoic acid (PABA) that also allowed for compensation of creatinine excretion when sampling was incomplete. We measured creatinine using the Jaffe method and PABA by the HPLC method. Participants were recruited from the capital city, a major town and a settlement (n = 36/48/20). They were aged 30-69 years with 78 Inuit and 26 non-Inuit. Inuit were smaller than non-Inuit (Caucasians): height, 163 vs. 177 cm, p Inuit compared to non-Inuit (men, 1344/1807 mg/24 h; women 894/1259 mg/24 h; p = 0.002; 0.02). It was influenced by age (p Inuit diet in the adjusted analysis. Creatinine excretion was described by: Inuit men, 1925 mg - (13.1 × age); Inuit women, 1701 mg - (17.0 × age). Inuit and Caucasians have different creatinine excretion. It is recommended to stratify by ethnicity in addition to adjustment for age and gender when using creatinine correction of spot urine samples.

  18. Kaiser Permanente Creatinine Safety Program: A Mechanism to Ensure Widespread Detection and Care for Chronic Kidney Disease.

    Science.gov (United States)

    Sim, John J; Rutkowski, Mark P; Selevan, David C; Batech, Michael; Timmins, Royann; Slezak, Jeff M; Jacobsen, Steven J; Kanter, Michael H

    2015-11-01

    Chronic kidney disease is highly prevalent but is challenging to diagnose because of the need to establish chronicity. Within the current healthcare environment, a single abnormal creatinine measurement often can go without a follow-up, which can lead to missed diagnoses or diagnostic errors. The Kaiser Permanente Southern California creatinine safety program (the Creatinine SureNet) was created to help ensure that all single abnormal creatinine results had a follow-up evaluation. In the period February 1, 2010, to March 1, 2014, the electronic health records were used to capture individuals with single abnormal creatinine results that went >90 days without a repeat measurement. A coordinated effort among a centralized regional nurse and providers was used to communicate with patients and order a repeat creatinine measurement. A total of 12,396 individuals were identified (84% ambulatory care encounters). A total of 6981 individuals (52%) followed up with a repeat measurement. Female patients, non-Hispanic whites, and older individuals were more likely to obtain a repeat measurement. Subsequently, 3668 individuals had chronic kidney disease confirmed. Within 6 months, 1550 patients had chart documentation of their chronic kidney disease and 336 patients had a nephrology consultation. The ambulatory care environment, given its high volume and various prioritizations, is an under-recognized area where diagnostic errors are not uncommon and failure to follow up on abnormal test results can occur routinely. The Kaiser Permanente Southern California Creatinine SureNet program leverages the electronic health records and its multidisciplinary resources in an effort to ensure that patients with potential chronic kidney disease are identified and managed properly. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Prediction of renal function (GFR) from cystatin C and creatinine in children: Body cell mass increases accuracy of the estimate

    DEFF Research Database (Denmark)

    Andersen, Trine Borup; Jødal, Lars; Bøgsted, Martin

    ) aged 2-14 years (mean 8.8 years). GFR was 14-147 mL/min/1.73m2 (mean 97 mL/min/1.73m2). BCM was estimated using bioimpedance spectroscopy (Xitron Hydra 4200). Log-transformed data on BCM/CysC, serum creatinine (SCr), body-surface-area (BSA), height x BSA/SCr, serum CysC, weight, sex, age, height, serum....... The present equation also had the highest R2 and the narrowest 95% limits of agreement. CONCLUSION: The new equation predicts GFR with higher accuracy than other equations. Endogenous methods are, however, still not accurate enough to replace exogenous markers when GFR must be determined with high accuracy...

  20. The Effect of Methanolic Extract of Otostegia persica on Serum Glucose Level and Renal Function Indicators in Streptozotocin Induced Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Mahdiye Hedayati

    2012-05-01

    Full Text Available Background: Regarding the antioxidant property of Otostegia persica extract and the role of antioxidants in Diabetes mellitus treatment, in this study the effect of extract on serum glucose level and renal function indicators was determined in diabetic male rats. Materials and Methods: Diabetes mellitus (type I was inducted in male rats using intraperitoneal injection of streptozotocin (STZ (65 mg/kg. To determine blood glucose, urea, and creatinine serum levels; fasting blood samples were collected twice (before STZ injection and 5 days later. The rats with their serum glucose level exceeding 250 mg/dl were considered diabetic and divided into 10 groups separately received Otostegia persica alcoholic extract (100, 200, and 300 mg/kg/day doses, glibenclamide with 600 µg/kg dose and 0.5 ml distilled water for 3 and 6 days using gavage. After 3 and 6 days, blood samples were collected again and glucose, urea, and creatinine serum levels were assessed using spectrophotometry technique by respective kits.Results: Treating diabetic rats by Otostegia persica extract (100, 200, and 300 mg/kg/day doses for 6 days results in a significant decrease of glucose and creatinine, yet an increase of serum urea with 200 mg/kg dose. Also, administration of the extract for 3 days (300 mg/kg reduced glucose, and (in various doses urea and creatinine serum levels. Conclusion: Otostegia persica extract has hypoglycemic effect and administering it in diabetes mellitus not only had no undesirable renal side effects, but also improved renal function to some extent.

  1. Estimation of Body Composition from Urinay Creatinine Excretion

    OpenAIRE

    小室, 史恵; 小宮, 秀一

    1982-01-01

    Simultaneous determinations of total body water, using the deuterium oxide dilution method, and urinary creatinine excretion have been carried out in 26 males and females. Total body water and FFM may be predicted from urinary creatinine excretion by T.B.W.=0.0165 Cr. +17.773. FFM=0.0225 Cr. +17.446. In this subjects a high correlation (r=0.874) was found between T.B.W, FFM and urinary creatinine excretion. It appears that FFM can be predicted from urinary creatinine excretion.

  2. Intra and interobserver variability of renal allograft ultrasound volume and resistive index measurements

    International Nuclear Information System (INIS)

    Mancini, Marcello; Liuzzi, Raffaele; Daniele, Stefania; Raffio, Teresa; Salvatore, Marco; Sabbatini, Massimo; Cianciaruso, Bruno; Ferrara, Liberato Aldo

    2005-01-01

    Purpose: Aim of the presents study was to evaluate the repeatability and reproducibility of the Doppler Resistive Index (R.I.) and the Ultrasound renal volume measurement in renal transplants. Materials and methods: Twenty -six consecutive patients (18 men, 8 women) mean age of 42,8±12,4 years (M±SD)(range 22-65 years) were studied twice by each of two trained sonographers using a color Doppler ultrasound scanner. Twelve of them had a normal allograft function (defined as stable serum creatinine levels ≤123,76 μmol/L), whilst the remaining 14 had decreased allograft function (serum creatinine 132.6-265.2 μmol/L). Results were given as mean of 6 measurements performed at upper, middle and lower pole of the kidney. Intra- and interobserver variability was assessed by the repeatability coefficient and coefficient of variation (CV). Results: Regarding Resistive Index measurement, repeatability coefficient was between 0.04 and 0.06 and the coefficient of variation was [it

  3. Colorimetric test-systems for creatinine detection based on composite molecularly imprinted polymer membranes.

    Science.gov (United States)

    Sergeyeva, T A; Gorbach, L A; Piletska, E V; Piletsky, S A; Brovko, O O; Honcharova, L A; Lutsyk, O D; Sergeeva, L M; Zinchenko, O A; El'skaya, A V

    2013-04-03

    An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N'-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25-2.5mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Clinical and prognostic value of spot urinary creatinine in chronic heart failure-An analysis from GISSI-HF.

    Science.gov (United States)

    Ter Maaten, Jozine M; Maggioni, Aldo Pietro; Latini, Roberto; Masson, Serge; Tognoni, Gianni; Tavazzi, Luigi; Signorini, Stefano; Voors, Adriaan A; Damman, Kevin

    2017-06-01

    This study aimed to identify patient characteristics associated with low urinary creatinine in morning spot urine and investigate its association with clinical outcome. Twenty-four-hour creatinine excretion is an established marker of muscle mass in heart failure and other populations. Spot urine creatinine might be an easy obtainable, cheap marker of muscle wasting and prognosis in heart failure (HF) patients. Spot urine creatinine concentration was measured in 2130 patients included in the GISSI-HF trial. We evaluated the prognostic value of urinary creatinine and its relation with clinical variables. Median spot urinary creatinine was 0.80 (IQR 0.50-1.10) g/L. Lower spot urinary creatinine was associated with older age, smaller height and weight, higher NYHA class, worse renal function and more frequent spironolactone and diuretic use (all Pcreatinine was independently associated with an increased risk of all-cause mortality or HF hospitalization (HR, 1.59 [1.21-2.08] per log decrease, P=.001), and all-cause mortality (HR, 1.75 [1.25-2.45] per log decrease, P=.001). Lower urinary creatinine, measured in morning spot urine in patients with chronic HF, is associated with worse renal function, smaller body size, more severe HF and is independently associated with an increased risk of all-cause death and HF hospitalization. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Serum Creatinine Distinguishes Duchenne Muscular Dystrophy from Becker Muscular Dystrophy in Patients Aged ≤3 Years: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    Liang Wang

    2017-05-01

    Full Text Available Here, we investigated correlations between serum creatinine (SCRN levels and clinical phenotypes of dystrophinopathy in young patients. Sixty-eight patients with dystrophinopathy at the Neuromuscular Clinic, The First Affiliated Hospital, Sun Yat-sen University, were selected for this study. The diagnosis of dystrophinopathy was based on clinical manifestation, biochemical changes, and molecular analysis. Some patients underwent muscle biopsies; SCRN levels were tested when patients were ≤3 years old, and reading frame changes were analyzed. Each patient was followed up, and motor function and clinical phenotype were assessed when the same patients were ≥4 years old. Our findings indicated that in young patients, lower SCRN levels were associated with increased disease severity (p < 0.01 and that SCRN levels were the highest in patients exhibiting mild Becker muscular dystrophy (BMD (p < 0.001 and the lowest in patients with Duchenne muscular dystrophy (DMD (p < 0.01 and were significantly higher in patients carrying in-frame mutations than in patients carrying out-of-frame mutations (p < 0.001. SCRN level cutoff values for identifying mild BMD [18 µmol/L; area under the curve (AUC: 0.947; p < 0.001] and DMD (17 µmol/L; AUC: 0.837; p < 0.001 were established. These results suggest that SCRN might be a valuable biomarker for distinguishing DMD from BMD in patients aged ≤3 years and could assist in the selection of appropriate treatment strategies.

  6. Dosing related effects of zoledronic acid on bone markers and creatinine clearance in patients with multiple myeloma and metastatic breast cancer

    DEFF Research Database (Denmark)

    Søe, Kent; Delaissé, Jean-Marie; Jakobsen, Erik H

    2014-01-01

    phase II clinical trial we investigated the effect of Zol treatment on the serum levels of the bone markers collagen type 1 cross-linked C-telopeptide (CTX) and bone specific alkaline phosphatase (bALP) as well as on creatinine clearance (kidney function) in response to dosing and duration of treatment...

  7. Automatic Reporting of Creatinine-Based Estimated Glomerular Filtration Rate in Children: Is this Feasible?

    Directory of Open Access Journals (Sweden)

    Andrew Lunn

    2016-07-01

    Full Text Available Creatinine, although widely used as a biomarker to measure renal function, has long been known as an insensitive marker of renal impairment. Patients with reduced renal function can have a creatinine level within the normal range, with a rapid rise when renal function is significantly reduced. As of 1976, the correlation between height, the reciprocal of creatinine, and measured glomerular filtration rate (GFR in children has been described. It has been used to derive a simple formula for estimated glomerular filtration rate (eGFR that could be used at the bedside as a more sensitive method of identifying children with renal impairment. Formulae based on this association, with modifications over time as creatinine assay methods have changed, are still widely used clinically at the bedside and in research studies to assess the degree of renal impairment in children. Adult practice has moved in many countries to computer-generated results that report eGFR alongside creatinine results using more complex, but potentially more accurate estimates of GFR, which are independent of height. This permits early identification of patients with chronic kidney disease. This review assesses the feasibility of automated reporting of eGFR and the advantages and disadvantages of this in children.

  8. Relationship of serum magnesium level and supplemental magnesium dosage with post coronary artery bypass graft surgery arrhythmias

    Directory of Open Access Journals (Sweden)

    Najafi M

    2007-06-01

    Full Text Available Background: Atrial and ventricular arrhythmias are among the most common complications after coronary artery bypass graft (CABG surgery. Previous studies demonstrated that cardiopulmonary bypass itself results in reduced serum magnesium levels. In this study, we evaluated the effect of total blood magnesium level (TMG on the prevention of perioperative arrhythmias with routine regimens of 2-4 grams supplemental magnesium (SMG. Methods: TMG was measured in patients who were scheduled for CABG on three occasions: just before anesthesia, just after entering the intensive care unit (ICU after completion of the sugery, and on the first morning after the operation. Patients were evaluated for primary cardiac rhythm and other variables that could have an influence on the magnesium level, including serum creatinine, urine output in the operating room and diuretic therapy. The SMG dosage was also recorded in the operating room and ICU. Patients were then evaluated for the rate and type of arrhythmia for the next three days. Results: The mean TMG levels in 174 cases were 2.2 (0.5, 2.6 (0.6 and 2.4 (0.6 mg/dl for the three occasions, respectively. The mean SMG was 2.5 (1.2 grams. Of 164 patients, 51 (31% developed the following post-operative arrhythmias: AF (7.3%, non-AF SVA (15.2% and ventricular (16.5%. The mean serum creatinine level and urine output were 1.2 mg/dl and 1800 ml, respectively. Although there was a significant difference between the TMG levels on the three different occasions (P<0.001, all values were within normal range. When we stratified the TMG levels of the patients based on administered SMG, the Mentel-Haenszel test revealed no significant difference between the first and third TMG (P=0.6. Although the TMG levels were higher in arrhythmic patients compared to those without arrhythmia (2.25 vs. 2.14 mg/dl, both values were within the normal range and there was no significant difference between the two groups. Serum creatinine levels

  9. Opium and heroin alter biochemical parameters of human's serum.

    Science.gov (United States)

    Kouros, Divsalar; Tahereh, Haghpanah; Mohammadreza, Afarinesh; Minoo, Mahmoudi Zarandi

    2010-05-01

    Iran is a significant consumer of opium, and, generally, of opioids, in the world. Addiction is one of the important issues of the 21st century and is an imperative issue in Iran. Long-term consumption of opioids affects homeostasis. To determine the effects of opium and heroin consumption on serum biochemical parameters. In a cross-sectional study, subjects who had consumed heroin (n = 35) or opium (n = 42) for more than two years and 35 nonaddict volunteers as the control group were compared in regard to various biochemical parameters such as fasting blood sugar (FBS), Na(+), K(+), Ca(2+), blood urea nitrogen (BUN), uric acid (UA), triglyceride (TG), cholesterol, creatinine, and total protein. Chromatography was used to confirm opioid consumption, and the concentration of biochemical parameters was determined by laboratory diagnostic tests on serum. No significant differences were found in Na(+), Ca(2+), BUN, UA, TG, creatinine, and total protein concentrations among the three groups. FBS, K(+), and UA levels were significantly lower in opium addicts compared to the control group. Serum Ca(2+) concentration of heroin addicts showed a significant decrease compared to that of the control group. Both addict groups showed a significant decrease in serum cholesterol levels. Chronic use of opium and heroin can change serum FBS, K(+), Ca(2+), UA, and cholesterol. This study, one of few on the effects of opium on serum biochemical parameters in human subjects, has the potential to contribute to the investigation of new approaches for further basic studies.

  10. Normal values of urine total protein- and albumin-to-creatinine ratios in term newborns.

    Science.gov (United States)

    El Hamel, Chahrazed; Chianea, Thierry; Thon, Séverine; Lepichoux, Anne; Yardin, Catherine; Guigonis, Vincent

    2017-01-01

    It is important to have an accurate assessment of urinary protein when glomerulopathy or kidney injury is suspected. Currently available normal values for the neonate population have limited value, in part because they are based on small populations and obsolete creatinine assays. We have performed a prospective study with the aim to update the normal upper values of the urinary total protein-to-creatinine and albumin-to-creatinine ratios in term newborns. Urine samples were collected from 277 healthy, full-term newborns within the first 48 hours (D0-1) and between 72 and 120 h of life (D3-4). Total protein, albumin, creatinine and osmolality were measured and the upper limit of normal (upper-limit) values determined. At D0-1 and D3-4, the upper-limit values for the total protein-to-creatinine ratio were 1431 and 1205 mg/g (162 and 136 g/mol) and those for the albumin-to-creatinine ratio were 746 and 301 mg/g (84 and 34 g/mol), respectively. The upper-limit values were significantly higher at D0-1 than at D3-4 only for the albumin-to-creatinine ratio. This study determined the upper limit of normal values for urinary total protein-to-creatinine and albumin-to-creatinine ratios in the largest population of newborns studied to date. These values can therefore be considered as the most clinically relevant data currently available for the detection and diagnosis of glomerular injury in daily clinical practice in this population.

  11. Perioperative change in creatinine following cardiac surgery with cardiopulmonary bypass is useful in predicting acute kidney injury: a single-centre retrospective cohort study.

    Science.gov (United States)

    Takaki, Shunsuke; Shehabi, Yahya; Pickering, John W; Endre, Zoltan; Miyashita, Tetsuya; Goto, Takahisa

    2015-10-01

    Acute kidney injury is common following cardiac surgery. Experimental models of acute kidney injury suggest that successful therapy should be implemented within 24-48 h of renal injury. However, it is difficult to detect acute kidney injury shortly after cardiac surgery, because creatinine concentration is diluted by cardiopulmonary bypass. We hypothesized that, following cardiopulmonary bypass, creatinine reduction ratios would correlate with haematocrit reduction ratios and would be associated with the incidence of acute kidney injury. We collected demographic and blood test data from consecutive patients (n = 1137) who had undergone cardiac surgery with cardiopulmonary bypass. The creatinine reduction ratio was calculated as follows: (preoperative creatinine-postoperative creatinine)/preoperative creatinine. Patients were assigned to either of two groups. The first group (Group 1) was used to determine the threshold for acute kidney injury, and the second group (Group 2) was used to assess diagnostic performance. Acute kidney injury was defined as an increase in serum creatinine level >0.3 mg/dl or >150% from baseline. The incidence of acute kidney injury was 14.5% (79/545) in Group 1 and 15.5% (92/592) in Group 2. Postoperatively, creatinine concentration correlated strongly with haematocrit concentration (Pearson's r(2): 0.91). In Group 1, the area under the receiver operating characteristic curve, sensitivity and specificity were 0.71, 64.1 and 66.4%, respectively, for creatinine reduction ratios of creatinine reduction ratio performance were 4.3 (95% confidence interval 2.6-7.0), 0.27 (0.21-0.32), 0.92 (0.89-0.95) and 3.42 (2.22-5.27), respectively. The creatinine reduction ratio may be associated with perioperative renal injury. Therefore, it is a good diagnostic indicator with high performance, and may be useful in detecting acute kidney injury at an earlier stage relative to conventional means. In addition, using creatinine reduction ratios in this manner

  12. Changes of serum dehydroepiandrosterone in patients with depression measured by radioimmunoassay

    International Nuclear Information System (INIS)

    Zhang Haisan; Zhang Hongxing; Meng Yan; Zhao Jingyuan; Du Yunhong

    2009-01-01

    To evaluate the reliability of radioimmunoassay for measuring serum neurosteroid dehydroepiandrosterone (DHEA) and to investigate the changes of serum DHEA level in depressive patients after treatment, the serum levels of DHEA in 40 health controls and in 40 depressive patients before and after treatment were measured by radioimmunassay. The results showed that the serum levels of DHEA in patient group before treatment were significantly lower than that in control group (P=0.001); it increased significantly after treatment (P=0.000) and were higher than that in control group (P=0.001). The serum levels of DHEA in both male and female patients after treatment were increased significantly compared with that before treatment (P=0.000). Radioimmunassay is convenient and reliable method and easy to use for the measurement of serum DHEA. The results indicate that the lower serum DHEA level in patients may be related to depression, it can be increased after treatment with antidepressant. (authors)

  13. Improving the measurement of longitudinal change in renal function: automated detection of changes in laboratory creatinine assay

    Directory of Open Access Journals (Sweden)

    Norman Poh

    2015-04-01

    Full Text Available IntroductionRenal function is reported using the estimates of glomerular filtration rate (eGFR. However, eGFR values are recorded without reference to the particular serum creatinine (SCr assays used to derive them, and newer assays were introduced at different time points across the laboratories in the United Kingdom. These changes may cause systematic bias in eGFR reported in routinely collected data, even though laboratory-reported eGFR values have a correction factor applied.DesignAn algorithm to detect changes in SCr that in turn affect eGFR calculation method was developed. It compares the mapping of SCr values on to eGFR values across a time series of paired eGFR and SCr measurements.SettingRoutinely collected primary care data from 20,000 people with the richest renal function data from the quality improvement in chronic kidney disease trial.ResultsThe algorithm identified a change in eGFR calculation method in 114 (90% of the 127 included practices. This change was identified in 4736 (23.7% patient time series analysed. This change in calibration method was found to cause a significant step change in the reported eGFR values, producing a systematic bias. The eGFR values could not be recalibrated by applying the Modification of Diet in Renal Disease equation to the laboratory reported SCr values.ConclusionsThis algorithm can identify laboratory changes in eGFR calculation methods and changes in SCr assay. Failure to account for these changes may misconstrue renal function changes over time. Researchers using routine eGFR data should account for these effects.  

  14. Sensitivity and Specificity of a Single Emergency Department Measurement of Urinary Neutrophil Gelatinase–Associated Lipocalin for Diagnosing Acute Kidney Injury

    Science.gov (United States)

    Nickolas, Thomas L.; O’Rourke, Matthew J.; Yang, Jun; Sise, Meghan E.; Canetta, Pietro A.; Barasch, Nicholas; Buchen, Charles; Khan, Faris; Mori, Kiyoshi; Giglio, James; Devarajan, Prasad; Barasch, Jonathan

    2010-01-01

    Background A single serum creatinine measurement cannot distinguish acute kidney injury from chronic kidney disease or prerenal azotemia. Objective To test the sensitivity and specificity of a single measurement of urinary neutrophil gelatinase–associated lipocalin (NGAL) and other urinary proteins to detect acute kidney injury in a spectrum of patients. Design Prospective cohort study. Setting Emergency department of Columbia University Medical Center, New York, New York. Participants 635 patients admitted to the hospital with acute kidney injury, prerenal azotemia, chronic kidney disease, or normal kidney function. Measurements Diagnosis of acute kidney injury was based on the RIFLE (risk, injury, failure, loss, and end-stage) criteria and assigned by researchers who were blinded to experimental measurements. Urinary NGAL was measured by immunoblot, N-acetyl-β-D-glucosaminidase (NAG) by enzyme measurement, α1-microglobulin and α1-acid glycoprotein by immunonephelometry, and serum creatinine by Jaffe kinetic reaction. Experimental measurements were not available to treating physicians. Results Patients with acute kidney injury had a significantly elevated mean urinary NGAL level compared with the other kidney function groups (416 μg/g creatinine [SD, 387]; P = 0.001). At a cutoff value of 130 μg/g creatinine, sensitivity and specificity of NGAL for detecting acute injury were 0.900 (95% CI, 0.73 to 0.98) and 0.995 (CI, 0.990 to 1.00), respectively, and positive and negative likelihood ratios were 181.5 (CI, 58.33 to 564.71) and 0.10 (CI, 0.03 to 0.29); these values were superior to those for NAG, α1-microglobulin, α1-acid glycoprotein, fractional excretion of sodium, and serum creatinine. In multiple logistic regression, urinary NGAL level was highly predictive of clinical outcomes, including nephrology consultation, dialysis, and admission to the intensive care unit (odds ratio, 24.71 [CI, 7.69 to 79.42]). Limitations All patients came from a single

  15. Relationship of Serum Vitamin D Concentrations and Allostatic Load as a Measure of Cumulative Biological Risk among the US Population: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Regina Frei

    Full Text Available The allostatic load (AL index is a multi-systemic measure of physiologic dysregulation known to be associated with chronic exposure to stress and adverse health outcomes. We examined the relationship between AL and serum 25-hydroxyvitamin D (25(OHD concentration in non-institutionalized US adults.Data from the Third National Health and Nutrition Examination Survey (NHANES III, 1988-94 were used to calculate two versions of AL including 9 biomarkers and another two with 14 biomarkers (systolic and diastolic blood pressure, pulse rate, serum cholesterol, serum HDL-cholesterol, glycated hemoglobin, sex-specific waist-to-hip ratio, serum albumin, and serum C-reactive protein for AL1, and, additionally body mass index, serum triglyceride, serum creatinine, and serum herpes I & II antibodies for AL2, each set defined by predefined cut-offs or by quartiles. Serum vitamin D concentration was ranked into quartiles. Logistic regression, Poisson regression and linear regression were used to examine the association of serum 25(OHD concentrations on AL, after adjusting for biological, physiological, socioeconomic, lifestyle, and health variables.Odds Ratios (OR for high AL of the lowest 25(OHD serum quartile were between 1.45 (95% CI: 1.28, 1.67 and 1.79 (95% CI: 1.39, 2.32 for the fully adjusted model, depending on AL version. Inverse relationships between vitamin D serum concentrations were observed for all AL versions and every adjustment. This relationship was consistent after stratification by sex, age or ethnic background. Sensitivity to low 25(OHD concentrations was highest among the youngest group (20-39 years with an OR of 2.11 (95% CI: 1.63, 2.73 for the lowest vitamin D quartile Q1.Vitamin D had a consistent and statistically significant inverse association with all tested models of high AL, which remained consistent after adjusting for biological, socioeconomic, lifestyle and health variables. Our study adds evidence linking low 25(OHD

  16. Accuracy of GFR estimation formula in determination of glomerular filtration rate in kidney donors: Comparison with 24 h urine creatinine clearance

    Directory of Open Access Journals (Sweden)

    Abdul Rauf Hafeez

    2016-01-01

    Full Text Available To determine the accuracy of estimated glomerular filtration rate (eGFR using the modification of diet in renal disease (MDRD, Cockcroft-Gault (CG, and chronic kidney disease epidemiology (CKD-EPI formulas in potential kidney donors compared with 24-h urine creatinine clearance, we studied 207 potential live kidney donors in our center. There were 126 (60.9% males and 81 (39.1% females. Male:female ratio was 1.6:1. The age of the donors ranged from 18-58 years, with mean age of 35.30 ± 9.23 years and most of the individuals were below 40 years of age. The body mass index (BMI was calculated and venous blood samples were obtained for the measurement of serum creatinine and every study participant was instructed to collect 24-h urine. GFR was calculated based on 24-h urine creatinine clearance and the formulas. The accuracy of GFR estimation formula was taken as positive if the GFR calculated by the formulas and urine creatinine clearance fell between 90-120 mL/min/1.73 m 2 . The accuracy of the MDRD formula was 48.8% and the CG formula was 41.5% whereas the accuracy of the CKD-EPI formula was 78.2%. The accuracy of the eGFR using the MDRD formula was significantly higher in males than females (57.9% vs. 33.3% P = 0.001, while there was no statistically significant difference in the eGFR between them in case of the use of the CG and the CKD-EPI formulas. BMI and obesity had no effect on the accuracy of eGFR by the use of the different formulas. The performance of GFR estimation formulas was sub optimal and these either underestimated and/or over-estimated the GFR in healthy subjects. CKD-EPI is closer to 24 -h urinary creatinine clearance in the calculation of eGFR. However, none of the eGFR formulas can be used in renal transplant donors because of their low accuracy, and 24-h urine creatinine clearance should be used for evaluation of the GFR in this population.

  17. Comparison of creatinine and cystatin C based eGFR in the estimation of glomerular filtration rate in Indigenous Australians: The eGFR Study.

    Science.gov (United States)

    Barr, Elizabeth Lm; Maple-Brown, Louise J; Barzi, Federica; Hughes, Jaquelyne T; Jerums, George; Ekinci, Elif I; Ellis, Andrew G; Jones, Graham Rd; Lawton, Paul D; Sajiv, Cherian; Majoni, Sandawana W; Brown, Alex Dh; Hoy, Wendy E; O'Dea, Kerin; Cass, Alan; MacIsaac, Richard J

    2017-04-01

    The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation that combines creatinine and cystatin C is superior to equations that include either measure alone in estimating glomerular filtration rate (GFR). However, whether cystatin C can provide any additional benefits in estimating GFR for Indigenous Australians, a population at high risk of end-stage kidney disease (ESKD) is unknown. Using a cross-sectional analysis from the eGFR Study of 654 Indigenous Australians at high risk of ESKD, eGFR was calculated using the CKD-EPI equations for serum creatinine (eGFRcr), cystatin C (eGFRcysC) and combined creatinine and cystatin C (eGFRcysC+cr). Reference GFR (mGFR) was determined using a non-isotopic iohexol plasma disappearance technique over 4h. Performance of each equation to mGFR was assessed by calculating bias, % bias, precision and accuracy for the total population, and according to age, sex, kidney disease, diabetes, obesity and c-reactive protein. Data were available for 542 participants (38% men, mean [sd] age 45 [14] years). Bias was significantly greater for eGFRcysC (15.0mL/min/1.73m 2 ; 95% CI 13.3-16.4, pcreatinine remains the preferred equation in Indigenous Australians. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Mechanism of renal excretion of creatinine by the pony

    International Nuclear Information System (INIS)

    Finco, D.R.; Groves, C.

    1985-01-01

    Free-flow and stop-flow procedures conducted on 2 female and 2 testosterone-treated castrated male ponies indicated that [ 14 C]inulin and exogenous creatinine clearance values were the same. These results indicated that creatinine was neither reabsorbed nor secreted by the renal tubules and that exogenous creatinine clearance was an accurate method for determining glomerular filtration rate. As in other species which have been studied, endogenous creatinine clearance probably underestimated glomerular filtration rate because of the presence of noncreatinine chromogens in plasma

  19. Accuracy of serum luteinizing hormone and serum testosterone measurements to assess the efficacy of medical castration in prostate cancer patients.

    Science.gov (United States)

    Morote, Juan; Comas, Imma; Ferrer, Roser; Planas, Jacques; Celma, Anna; Regis, Lucas

    2017-10-22

    Luteinizing hormone-releasing hormone (LH-RH) agonists are the standard for androgen deprivation therapy (ADT) in prostate cancer (PCa) patients. Current guidelines recommend serum testosterone measurement to assess the efficacy of ADT and to define castration resistance. However, serum testosterone does not reflect the exclusive effect of castration due to its extratesticular production. The aim of this study is to analyze if serum LH reflects better than serum testosterone the activity of LH-RH agonists. Serum LH and serum testosterone were measured with chemiluminescent immunoassay (CLIA) in a cohort study of 1091 participants: 488 PCa patients "on LH-RH agonists", 303 "off LH-RH agonist" in whom LH-RH agonists were withdrawn, and 350 men with PCa suspicion "no LH-RH agonist" who never received LH-RH agonists. In a validation cohort of 147 PCa patients, 124 on "LH-RH agonists" and 19 "off LH-RH agonists", serum testosterone was also measured with liquid chromatography and tandem mass spectrometry (LC MSMS). The area under the curve (AUC) to distinguish patients "on versus off LH-RH agonists" was 0.997 for serum LH and 0.740 for serum testosterone, P < 0.001. The 97.5 percentile of serum LH in patients "on LH-RH agonists" was 0.97 U/L, been the most efficient threshold 1.1 U/L. The AUCs for serum LH, testosterone measured with CLIA and with LC MSMS, in the validation cohort, were respectively 1.000, 0.646 and 0.814, P < 0.001. The efficacy to distinguish patients "on versus off LH-RH agonists" was 98.6%, 78.3%, and 89.5% respectively, using 1.1 U/L as threshold for serum LH and 50 ng/dL for serum testosterone regardless the method. Serum LH is more accurate than serum testosterone regardless the method, to distinguish patients "on versus off LH-RH agonists". The castrate level of serum LH is 1.1 U/l. These findings suggest that assessment of LH-RH agonist efficacy and castration resistance definition should be reviewed.

  20. Decrease in urinary creatinine excretion in early stage chronic kidney disease.

    Directory of Open Access Journals (Sweden)

    Elena Tynkevich

    Full Text Available BACKGROUND: Little is known about muscle mass loss in early stage chronic kidney disease (CKD. We used 24-hour urinary creatinine excretion rate to assess determinants of muscle mass and its evolution with kidney function decline. We also described the range of urinary creatinine concentration in this population. METHODS: We included 1072 men and 537 women with non-dialysis CKD stages 1 to 5, all of them with repeated measurements of glomerular filtration rate (mGFR by (51Cr-EDTA renal clearance and several nutritional markers. In those with stage 1 to 4 at baseline, we used a mixed model to study factors associated with urinary creatinine excretion rate and its change over time. RESULTS: Baseline mean urinary creatinine excretion decreased from 15.3 ± 3.1 to 12.1 ± 3.3 mmol/24 h (0.20 ± 0.03 to 0.15 ± 0.04 mmol/kg/24 h in men, with mGFR falling from ≥ 60 to <15 mL/min/1.73 m(2, and from 9.6 ± 1.9 to 7.6 ± 2.5 (0.16 ± 0.03 to 0.12 ± 0.03 in women. In addition to mGFR, an older age, diabetes, and lower levels of body mass index, proteinuria, and protein intake assessed by urinary urea were associated with lower mean urinary creatinine excretion at baseline. Mean annual decline in mGFR was 1.53 ± 0.12 mL/min/1.73 m(2 per year and that of urinary creatinine excretion rate, 0.28 ± 0.02 mmol/24 h per year. Patients with fast annual decline in mGFR of 5 mL/min/1.73 m(2 had a decrease in urinary creatinine excretion more than twice as big as in those with stable mGFR, independent of changes in urinary urea as well as of other determinants of low muscle mass. CONCLUSIONS: Decrease in 24-hour urinary creatinine excretion rate may appear early in CKD patients, and is greater the more mGFR declines independent of lowering protein intake assessed by 24-hour urinary urea. Normalizing urine analytes for creatininuria may overestimate their concentration in patients with reduced kidney function and low muscle mass.

  1. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.

    Science.gov (United States)

    Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J

    2015-02-01

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.

  2. Serum Lipase as Clinical Laboratory Index for Chronic Renal Failure Diagnosis.

    Science.gov (United States)

    Zhu, Ying; Dong, Jing; Wang, Ping; Huang, Huifang; Jin, Xiaohua; Zhou, Jingou; Shi, Jingfang; Gu, Guohao; Chen, Jun; Xu, Jun; Song, Yanhui

    2016-07-01

    Measuring the level of serum lipase has been used for the clinical diagnosis of acute pancreatitis. Reports showed that the serum lipase level increased in patients of clinical renal failure. In this study, we aimed to measure the change of serum lipase levels in chronic kidney diseases and determine whether it could serve as a clinical laboratory index for clinical renal failure diagnosis. Materials: The OLYMPUS AU5400 automatic biochemical analyzer was used to determine the serum levels of lipase and creatinine. The study included 120 cases in the clinical renal failure group, 76 cases in the nephrotic syndrome group, 81 cases in the chronic nephritis group, and 80 healthy controls from our hospital volunteers in the same period. We then compared the lipase levels and conducted statistical analyses among these groups. The serum lipase levels were 15.3 U/L, 79.8 U/L, 45.1 U/L, and 51.0 U/L in the normal control, clinical renal failure, nephrotic syndrome, and chronic nephritis groups, respectively. The lipase levels in the groups with diseases were significantly different compared with that of the normal control group (p renal failure group was significantly higher than that of the nephrotic syndrome group and chronic nephritis group (p chronic nephritis group (p > 0.05) was observed. Moreover, an association of the serum lipase with disease progression was observed in the study. Serum lipase is an effective serological index which can reflect the clinical changes in the clinical renal failure and tends to increase through the progression of renal dysfunction.

  3. Impact of estimated glomerular filtration rate based on plasma cystatin C and serum creatinine levels before allogeneic hematopoietic cell transplantation.

    Science.gov (United States)

    Wada, Hidenori; Kanda, Junya; Akahoshi, Yu; Nakano, Hirofumi; Ugai, Tomotaka; Yamasaki, Ryoko; Ishihara, Yuko; Kawamura, Koji; Sakamoto, Kana; Ashizawa, Masahiro; Sato, Miki; Terasako-Saito, Kiriko; Kimura, Shun-Ichi; Kikuchi, Misato; Nakasone, Hideki; Yamazaki, Rie; Kako, Shinichi; Tanihara, Aki; Nishida, Junji; Kanda, Yoshinobu

    2018-06-01

    No standard method for measuring renal function has been established in allogeneic hematopoietic cell transplantation (allo-HCT). We retrospectively analyzed 80 patients with hematological diseases who underwent allo-HCT at our center. We assessed renal function using creatinine clearance (Ccr), estimated glomerular filtration rate (eGFR) based on creatinine (eGFRcre), eGFR based on cystatin C (eGFRcys), and the average of eGFRcre and eGFRcys (eGFRave). We then evaluated the impact of pre-transplant renal function on the exacerbation of renal function and non-relapse mortality after transplantation. There was a significant correlation between Ccr and eGFRcre, eGFRcys, and eGFRave. eGFRave best predicted the exacerbation of renal function according to the area under the receiver-operating characteristic curve. The cumulative incidence of renal function exacerbation at 1 year was higher in the lower eGFRave group (<90 ml/min/1.73 m 2 ) than in the higher eGFRave group (≥90 ml/min/1.73 m 2 ; 0.85 vs. 0.39, p < 0.001), which was confirmed by a multivariate analysis (HR 2.75, p = 0.001). A lower eGFRave value was a marginally significant factor for non-relapse mortality (HR 3.29, p = 0.076). Among the four parameters, eGFRave best predicted the exacerbation of renal function in allo-HCT. Further, the marginal association between low eGFRave and high non-relapse mortality warrants further study in a prospective study in allo-HCT.

  4. Equations to Estimate Creatinine Excretion Rate : The CKD Epidemiology Collaboration

    NARCIS (Netherlands)

    Ix, Joachim H.; Wassel, Christina L.; Stevens, Lesley A.; Beck, Gerald J.; Froissart, Marc; Navis, Gerjan; Rodby, Roger; Torres, Vicente E.; Zhang, Yaping (Lucy); Greene, Tom; Levey, Andrew S.

    Background and objectives Creatinine excretion rate (CER) indicates timed urine collection accuracy. Although equations to estimate CER exist, their bias and precision are untested and none simultaneously include age, sex, race, and weight. Design, setting, participants, & measurements Participants

  5. Effects of hydrochlorothiazide and furosemide on creatinine ...

    African Journals Online (AJOL)

    Hydrochlorothiazide and furosemide have been reported to alter the glomerular filtration rate (GFR) and possibly the creatinine excretion by the kidneys. Also, therapy with these diuretics, especially in the elderly, can be complicated by volume depletion resulting in prerenal azotemia. Creatinine clearance (Clcr) is ...

  6. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio

    Science.gov (United States)

    Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-01-01

    Background and objectives Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Design, setting, participants, & measurements Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long–term frozen storage at −80°C, −40°C, and −20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Results Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20–499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at −80°C or −40°C but not at −20°C. Conclusions Mailed urine samples collected with preservative and received within 7 days if

  7. Degradability of creatinine under sewer conditions affects its potential to be used as biomarker in sewage epidemiology.

    Science.gov (United States)

    Thai, Phong K; O'Brien, Jake; Jiang, Guangming; Gernjak, Wolfgang; Yuan, Zhiguo; Eaglesham, Geoff; Mueller, Jochen F

    2014-05-15

    Creatinine was proposed to be used as a population normalising factor in sewage epidemiology but its stability in the sewer system has not been assessed. This study thus aimed to evaluate the fate of creatinine under different sewer conditions using laboratory sewer reactors. The results showed that while creatinine was stable in wastewater only, it degraded quickly in reactors with the presence of sewer biofilms. The degradation followed first order kinetics with significantly higher rate in rising main condition than in gravity sewer condition. Additionally, daily loads of creatinine were determined in wastewater samples collected on Census day from 10 wastewater treatment plants around Australia. The measured loads of creatinine from those samples were much lower than expected and did not correlate with the populations across the sampled treatment plants. The results suggested that creatinine may not be a suitable biomarker for population normalisation purpose in sewage epidemiology, especially in sewer catchment with high percentage of rising mains. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Radioimmunological determination of digoxin in serum

    International Nuclear Information System (INIS)

    Gruber, G.; Sorger, D.

    1979-01-01

    The tested quality signs of the digoxin-RIA (Medica) correspond to other RIA-test methods. The digoxin-RIA (Medica) is, therefore, well suited for clinical examinations. In the dilanacin-(digoxin-) long-term therapy with the maintenance dose of 0.5 mg digoxin a day 75.4% of the patients examined (n = 65) were within the therapeutic field. In each case 12.3% were underdigitalised or overdigitalised, respectively. In the 8 patients in the toxic region only the half showed signs of digoxin intoxication. It is referred to the importance of creatinine and potassium in the serum, to the digoxin creatinene and potassium in the serum, to the digoxin clearance depending on age, to the body weight and the body surface, respectively, in very obese patients for the height of the serum digoxin level and for the compatibility of this heart glycoside. (author)

  9. Effect of Processing Delay and Storage Conditions on Urine Albumin-to-Creatinine Ratio.

    Science.gov (United States)

    Herrington, William; Illingworth, Nicola; Staplin, Natalie; Kumar, Aishwarya; Storey, Ben; Hrusecka, Renata; Judge, Parminder; Mahmood, Maria; Parish, Sarah; Landray, Martin; Haynes, Richard; Baigent, Colin; Hill, Michael; Clark, Sarah

    2016-10-07

    Because there is substantial biologic intraindividual variation in albumin excretion, randomized trials of albuminuria-reducing therapies may need multiple urine samples to estimate daily urinary albumin excretion. Mailing spot urine samples could offer a convenient and cost-effective method to collect multiple samples, but urine albumin-to-creatinine ratio stability in samples stored at ambient temperatures for several days is unknown. Patients with kidney disease provided fresh urine samples in two tubes (with and without boric acid preservative). Reference aliquots from each participant were analyzed immediately, whereas remaining aliquots were subject to different handling/storage conditions before analysis, including delayed processing for up to 7 days at three different storage temperatures (4°C, 18°C, and 30°C), multiple freeze-thaw cycles, and long-term frozen storage at -80°C, -40°C, and -20°C. We calculated the mean percentage change in urine albumin-to-creatinine ratio for each condition, and we considered samples stable if the 95% confidence interval was within a ±5% threshold. Ninety-three patients provided samples with detectable albuminuria in the reference aliquot. Median (interquartile range) urine albumin-to-creatinine ratio was 87 (20-499) mg/g. The inclusion of preservative had minimal effect on fresh urine albumin-to-creatinine ratio measurements but reduced the changes in albumin and creatinine in samples subject to processing delay and storage conditions. The urine albumin-to-creatinine ratio was stable for 7 days in samples containing preservative at 4°C and 18°C and 2 days when stored at 30°C. It was also stable in samples with preservative after three freeze-thaw cycles and in frozen storage for 6 months at -80°C or -40°C but not at -20°C. Mailed urine samples collected with preservative and received within 7 days if ambient temperature is ≤18°C, or within 2 days if the temperature is higher but does not exceed 30°C, are

  10. Population Reference Values for Serum Methylmalonic Acid Concentrations and Its Relationship with Age, Sex, Race-Ethnicity, Supplement Use, Kidney Function and Serum Vitamin B12 in the Post-Folic Acid Fortification Period

    Directory of Open Access Journals (Sweden)

    Vijay Ganji

    2018-01-01

    Full Text Available Serum methylmalonic acid (MMA is elevated in vitamin B-12 deficiency and in kidney dysfunction. Population reference values for serum MMA concentrations in post-folic acid fortification period are lacking. Aims of this study were to report the population reference values for serum MMA and to evaluate the relation between serum MMA and sex, age, race-ethnicity, kidney dysfunction and vitamin B-12. We used data from three National Health and Nutrition Examination Surveys, 1999–2000, 2001–2002 and 2003–2004 conducted after folic acid fortification commenced (n = 18,569. Geometric mean MMA was ≈22.3% higher in non-Hispanic white compared to non-Hispanic black (141.2 vs. 115.5 nmol/L and was ≈62.7% higher in >70 years old persons compared to 21–30 years old persons (196.9 vs. 121.0 nmol/L. Median serum MMA was ≈28.5% higher in the 1st the quartile of serum vitamin B-12 than in the 4th quartile of serum vitamin B-12 and was ≈35.8% higher in the 4th quartile of serum creatinine than in the 1st quartile of serum creatinine. Multivariate-adjusted serum MMA concentration was significantly associated with race-ethnicity (p < 0.001 and age (p < 0.001 but not with sex (p = 0.057. In this large US population based study, serum MMA concentrations presented here reflect the post-folic acid fortification scenario. Serum MMA concentrations begin to rise at the age of 18–20 years and continue to rise afterwards. Age-related increase in serum MMA concentration is likely to be due to a concomitant decline in kidney function and vitamin B-12 status.

  11. A critical evalution of 24 hours whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Bessent, R.G.; Scullion, J.E.; Cuthbert, G.F.

    1982-01-01

    In previous studies we have found that 24 hour whole-body retention (WBR) of diphosphonate is a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r = 0.998, p < 0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. The net whole-body count of a phantom representing the 24 hour whole-body distribution of tracer was 98% of that of a uniform phantom. Ten subjects, counted twice within a few minutes to study the effect of repositioning showed a mean difference between counts of only 0.8%. For eleven subjects with traumatic fractures it was found that 9 had normal values for WBR, while 2 had minimally elevated results. For twenty patients with renal disease but no apparent skeletal disease a significant correlation between serum creatinine and WBR was found (r = 0.72, p<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/l. It is suggested that WBR measurement is accurate and the technique is highly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is in the normal range then an elevated WBR result can be assumed to reflect increased skeletal metabolism without further concern as to renal function. (Author)

  12. Label free sensing of creatinine using a 6 GHz CMOS near-field dielectric immunosensor.

    Science.gov (United States)

    Guha, S; Warsinke, A; Tientcheu, Ch M; Schmalz, K; Meliani, C; Wenger, Ch

    2015-05-07

    In this work we present a CMOS high frequency direct immunosensor operating at 6 GHz (C-band) for label free determination of creatinine. The sensor is fabricated in standard 0.13 μm SiGe:C BiCMOS process. The report also demonstrates the ability to immobilize creatinine molecules on a Si3N4 passivation layer of the standard BiCMOS/CMOS process, therefore, evading any further need of cumbersome post processing of the fabricated sensor chip. The sensor is based on capacitive detection of the amount of non-creatinine bound antibodies binding to an immobilized creatinine layer on the passivated sensor. The chip bound antibody amount in turn corresponds indirectly to the creatinine concentration used in the incubation phase. The determination of creatinine in the concentration range of 0.88-880 μM is successfully demonstrated in this work. A sensitivity of 35 MHz/10 fold increase in creatinine concentration (during incubation) at the centre frequency of 6 GHz is gained by the immunosensor. The results are compared with a standard optical measurement technique and the dynamic range and sensitivity is of the order of the established optical indication technique. The C-band immunosensor chip comprising an area of 0.3 mm(2) reduces the sensing area considerably, therefore, requiring a sample volume as low as 2 μl. The small analyte sample volume and label free approach also reduce the experimental costs in addition to the low fabrication costs offered by the batch fabrication technique of CMOS/BiCMOS process.

  13. Accuracy of 24-h whole-body (skeletal) retention of diphosphonate measurements

    International Nuclear Information System (INIS)

    Fogelman, I.; Scullion, J.E.; Bessent, R.; Cuthbert, G.F.

    1982-01-01

    The 24-h whole-body retention (WBR) of diphosphonate was a valuable test for the assessment of skeletal metabolism. However, the reproducibility, accuracy and possible sources of error in WBR measurements have not previously been studied. In 21 paired studies the technique was found to be highly reproducible (r=0.998, R<0.0001). The coefficient of variation for whole-body counts on day 1 was 0.1% and on day 2, 1.1%. A phantom was used to assess the possible error introduced by redistribution of tracer. The net whole-body count of the phantom representing the 24-h distribution was 98% of that of a uniform phantom. Ten subjects were counted twice within a few minutes to study the effect of repositioning, and showed a mean difference between counts of only 0.8%. Eleven subjects with traumatic fractures were studied to assess the possible contribution of focal lesions to WBR. It was found that nine subjects had normal values for WBR, while two had minimally elevated results. Twenty patients with renal disease but no apparent skeletal disease were also studied to assess the possible contribution of soft-tissue retention to WBR. A significant correlation between serum creatinine and WBR was found (r=0.72, P<0.001). However WBR results were always normal when serum creatinine values were <130 μmol/1. It is suggested that WBR measurement is accurate and the technique is hgihly reproducible. The presence of a focal lesion is unlikely to affect a WBR result significantly and if serum creatinine is the normal range then WBR can be assumed to reflect skeletal metabolism without further concern as to renal function. (orig.)

  14. Urinary orotic acid-to-creatinine ratios in cats with hepatic lipidosis.

    Science.gov (United States)

    VanSteenhouse, J L; Dimski, D S; Swenson, D H; Taboada, J

    1999-06-01

    To determine urinary orotic acid (OA) concentration and evaluate the urinary OA-to-creatinine ratio (OACR) in cats with hepatic lipidosis (HL). 20 cats with HL and 20 clinically normal cats. Hepatic lipidosis was diagnosed on the basis of clinical signs, results of serum biochemical analyses, exclusion of other concurrent illness, and cytologic or histologic evaluation of liver biopsy specimens. Urine samples were collected from each cat and frozen at -20 C until assayed. Urine creatinine concentrations were determined, using an alkaline picrate method followed by spectrophotometric assay. Urine OA concentration was determined, using high-performance liquid chromatography. Minimum amount of detectable OA in feline urine was 1 microg/ml. Because of small interfering peaks near the base of the OA peak, the minimum quantifiable concentration of OA was determined to be 5 microg/ml. Urinary OACR was compared in both groups of cats. Differences in urinary OACR were not detected between clinically normal cats and cats with HL. Peaks were not detected for urinary OA in any of the 20 clinically normal cats. Of the 20 HL cats, 14 did not have detectable peaks for urinary OA. Of the 6 HL cats that had detectable urinary OA peaks, 3 had values of <5 microg/ml. Apparently, OACR does not increase significantly in cats with HL. Urinary OACR is not a useful diagnostic test for HL in cats.

  15. EVALUATION OF DISPOSABLE DIAPERS FOR QUANTATIVE MEASUREMENTS OF PESTICIDE METABOLITES AND CREATININE IN URINE SAMPLES

    Science.gov (United States)

    This project consisted of a laboratory study to evaluate an extraction and analysis method for quantifying biomarkers of pesticide exposure and creatinine in urine samples collected with commercially-available disposable diapers. For large exposure studies, such as the National ...

  16. Nadir creatinine in posterior urethral valves: How high is low enough?

    Science.gov (United States)

    Coleman, R; King, T; Nicoara, C-D; Bader, M; McCarthy, L; Chandran, H; Parashar, K

    2015-12-01

    Large retrospective studies of people with posterior urethral valves (PUV) have reported chronic renal insufficiency (CRI) in up to one third of the participants and end-stage renal failure in up to one quarter of them. Nadir creatinine (lowest creatinine during the first year following diagnosis) is the recognised prognostic indicator for renal outcome in PUV, the most commonly used cut-off being 1 mg/dl (88.4 umol/l). To conduct a statistical analysis of nadir creatinine in PUV patients in order to identify the optimal cut-off level as a prognostic indicator for CRI. Patients treated by endoscopic valve ablation at the present institution between 1993 and 2004 were reviewed. Chronic renal insufficiency was defined as CKD2 or higher. Statistical methods included receiver operating characteristic (ROC) curve analysis, Fisher exact test and diagnostic utility tests. Statistical significance was defined as P creatinine was identified in 96 patients. The median follow-up was 9.4 (IQR 7.0, 13.4) years. A total of 29 (30.2%) patients developed CRI, with nine (9.4%) reaching end-stage renal failure. On ROC analysis, Nadir creatinine was highly prognostic for future CRI, with an Area Under the Curve of 0.887 (P creatinine >88.4 umol/l compared with 19 of 86 (22.2%) patients with lower nadir creatinine (P creatinine cut-off of 88.4 umol/l gave a specificity of 100%, but poor sensitivity of 34.5%. Lowering the cut-off to 75 umol/l resulted in improvement in all diagnostic utility tests (Table). All 14 (100%) patients with nadir creatinine >75 umol/l developed CRI, compared with 15 of 82 (18.3%) patients with lower nadir creatinine (P creatinine creatinine >75 umol/l (OR 48.988; CI 4.9-490.11) to be independent risk factors for progression to CRI. Using cut-off values of 35 umol/l and 75 umol/l, patients can be stratified into low-, intermediate- and high-risk groups, with development of CRI in 5.3%, 28.3% and 100%, respectively (P creatinine >75 umol/l (0.85

  17. Detection of urinary creatinine using gold nanoparticles after solid phase extraction

    Science.gov (United States)

    Sittiwong, Jarinya; Unob, Fuangfa

    2015-03-01

    Label-free gold nanoparticles (AuNPs) were utilized in the detection of creatinine in human urine after a sample preparation by extraction of creatinine on sulfonic acid functionalized silica gel. With the proposed sample preparation method, the interfering effects of the urine matrix on creatinine detection by AuNPs were eliminated. Parameters affecting creatinine extraction were investigated. The aggregation of AuNPs induced by creatinine resulted in a change in the surface plasmon resonance signal with a concomitant color change that could be observed by the naked eye and quantified spectrometrically. The effect of AuNP concentration and reaction time on AuNP aggregation was investigated. The method described herein provides a determination of creatinine in a range of 15-40 mg L-1 with a detection limit of 13.7 mg L-1 and it was successfully used in the detection of creatinine in human urine samples.

  18. LC-MS-MS Measurements of Urinary Creatinine and the Application of Creatinine Normalization Technique on Cotinine in Smokers’ 24 Hour Urine

    OpenAIRE

    Hongwei Hou; Wei Xiong; Xiaotao Zhang; Dongkui Song; Gangling Tang; Qingyuan Hu

    2012-01-01

    A simple and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-ESI-MS-MS) method was developed and validated for the quantification of creatinine in human urine. The analysis was carried out on an Agilent Zorbax Eclipse XDB-C18 column (2.1 × 150 mm, 3.5  μ m). The mobile phase was 0.1% formic acid in water and 0.1% formic acid in acetonitrile (50/50, v/v). Linear calibration curves were obtained in the concentration range of 1–2000.0 ng/mL, with a lower limit of ...

  19. Recovery from radiation induced changes in some protein end-products in the liver and blood serum of irradiated rats

    International Nuclear Information System (INIS)

    Elkashef, H.S.; Roushdy, H.M.; Saada, H.N.; Abdelsamie, M.A.

    1989-01-01

    When rats were subjected to whole body gamma-irradiation at the dose of 5.5 Gy it caused significant changes in the content of urea and creatine the serum at 7 and 14 days postirradiation. In the liver significant changes were observed in the content of urea, creatine and creatinine at all post-irradiation days except the third day for urea and seventh day for creatine. Ten days pre-irradiation of the rats a mixture of 5 mg testosterone propionate and 10 mg of vitamin E was intraperitoneally injected. The results indicated that this mixture could help in obtaining complete recovery for radiation induced changes in the content of urea in both liver and serum of irradiated protected rats. Also this mixture provided good protection and caused recovery from radiation induced changes in the liver creatine on the third and seventh days after irradiation. But for serum creatine, the recovery was observed only on the third post irradiation day. The applied radiation dose did not induce any significant changes in the level of serum creatinine, while a partial recovery was noticed for liver creatinine in irradiated protected rats. The recovery process seems to be related to the radiosensitivity of the animal tissue, with the chemical structure of the radioprotector substances and the estimated compounds as well as the post-irradiation time intervals.3 tab

  20. Quantifying creatinine and urea in human urine through Raman spectroscopy aiming at diagnosis of kidney disease

    Science.gov (United States)

    Saatkamp, Cassiano Junior; de Almeida, Maurício Liberal; Bispo, Jeyse Aliana Martins; Pinheiro, Antonio Luiz Barbosa; Fernandes, Adriana Barrinha; Silveira, Landulfo, Jr.

    2016-03-01

    Due to their importance in the regulation of metabolites, the kidneys need continuous monitoring to check for correct functioning, mainly by urea and creatinine urinalysis. This study aimed to develop a model to estimate the concentrations of urea and creatinine in urine by means of Raman spectroscopy (RS) that could be used to diagnose kidney disease. Midstream urine samples were obtained from 54 volunteers with no kidney complaints. Samples were subjected to a standard colorimetric assay of urea and creatinine and submitted to spectroscopic analysis by means of a dispersive Raman spectrometer (830 nm, 350 mW, 30 s). The Raman spectra of urine showed peaks related mainly to urea and creatinine. Partial least squares models were developed using selected Raman bands related to urea and creatinine and the biochemical concentrations in urine measured by the colorimetric method, resulting in r=0.90 and 0.91 for urea and creatinine, respectively, with root mean square error of cross-validation (RMSEcv) of 312 and 25.2 mg/dL, respectively. RS may become a technique for rapid urinalysis, with concentration errors suitable for population screening aimed at the prevention of renal diseases.

  1. Assessing glomerular filtration rate (GFR) in critically ill patients with acute kidney injury - true GFR versus urinary creatinine clearance and estimating equations

    Science.gov (United States)

    2013-01-01

    Introduction Estimation of kidney function in critically ill patients with acute kidney injury (AKI), is important for appropriate dosing of drugs and adjustment of therapeutic strategies, but challenging due to fluctuations in kidney function, creatinine metabolism and fluid balance. Data on the agreement between estimating and gold standard methods to assess glomerular filtration rate (GFR) in early AKI are lacking. We evaluated the agreement of urinary creatinine clearance (CrCl) and three commonly used estimating equations, the Cockcroft Gault (CG), the Modification of Diet in Renal Disease (MDRD) and the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, in comparison to GFR measured by the infusion clearance of chromium-ethylenediaminetetraacetic acid (51Cr-EDTA), in critically ill patients with early AKI after complicated cardiac surgery. Methods Thirty patients with early AKI were studied in the intensive care unit, 2 to 12 days after complicated cardiac surgery. The infusion clearance for 51Cr-EDTA obtained as a measure of GFR (GFR51Cr-EDTA) was calculated from the formula: GFR (mL/min/1.73m2) = (51Cr-EDTA infusion rate × 1.73)/(arterial 51Cr-EDTA × body surface area) and compared with the urinary CrCl and the estimated GFR (eGFR) from the three estimating equations. Urine was collected in two 30-minute periods to measure urine flow and urine creatinine. Urinary CrCl was calculated from the formula: CrCl (mL/min/1.73m2) = (urine volume × urine creatinine × 1.73)/(serum creatinine × 30 min × body surface area). Results The within-group error was lower for GFR51Cr-EDTA than the urinary CrCl method, 7.2% versus 55.0%. The between-method bias was 2.6, 11.6, 11.1 and 7.39 ml/min for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. The error was 103%, 68.7%, 67.7% and 68.0% for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. Conclusions The study

  2. A role for the organic anion transporter OAT3 in renal creatinine secretion in mice

    Science.gov (United States)

    Eraly, Satish A.; Rao, Satish Ramachandra; Gerasimova, Maria; Rose, Michael; Nagle, Megha; Anzai, Naohiko; Smith, Travis; Sharma, Kumar; Nigam, Sanjay K.; Rieg, Timo

    2012-01-01

    Tubular secretion of the organic cation, creatinine, limits its value as a marker of glomerular filtration rate (GFR) but the molecular determinants of this pathway are unclear. The organic anion transporters, OAT1 and OAT3, are expressed on the basolateral membrane of the proximal tubule and transport organic anions but also neutral compounds and cations. Here, we demonstrate specific uptake of creatinine into mouse mOat1- and mOat3-microinjected Xenopus laevis oocytes at a concentration of 10 μM (i.e., similar to physiological plasma levels), which was inhibited by both probenecid and cimetidine, prototypical competitive inhibitors of organic anion and cation transporters, respectively. Renal creatinine clearance was consistently greater than inulin clearance (as a measure of GFR) in wild-type (WT) mice but not in mice lacking OAT1 (Oat1−/−) and OAT3 (Oat3−/−). WT mice presented renal creatinine net secretion (0.23 ± 0.03 μg/min) which represented 45 ± 6% of total renal creatinine excretion. Mean values for renal creatinine net secretion and renal creatinine secretion fraction were not different from zero in Oat1−/− (−0.03 ± 0.10 μg/min; −3 ± 18%) and Oat3−/− (0.01 ± 0.06 μg/min; −6 ± 19%), with greater variability in Oat1−/−. Expression of OAT3 protein in the renal membranes of Oat1−/− mice was reduced to ∼6% of WT levels, and that of OAT1 in Oat3−/− mice to ∼60%, possibly as a consequence of the genes for Oat1 and Oat3 having adjacent chromosomal locations. Plasma creatinine concentrations of Oat3−/− were elevated in clearance studies under anesthesia but not following brief isoflurane anesthesia, indicating that the former condition enhanced the quantitative contribution of OAT3 for renal creatinine secretion. The results are consistent with a contribution of OAT3 and possibly OAT1 to renal creatinine secretion in mice. PMID:22338083

  3. Creatinine, eGFR and association with myocardial infarction, ischemic heart disease and early death in the general population

    DEFF Research Database (Denmark)

    Sibilitz, Kirstine L; Benn, Marianne; Nordestgaard, Børge G

    2014-01-01

    OBJECTIVE: We tested the hypothesis that moderately elevated plasma creatinine levels and decreased levels of estimated glomerular filtration rate (eGFR) are associated with increased risk of myocardial infarction, ischemic heart disease, and early death in the general population. METHODS: We...... studied 10,489 individuals with a plasma creatinine measurement and calculated eGFR from the Danish general population, of which 1498 developed myocardial infarction, 3001 ischemic heart disease, and 7573 died during 32 years follow-up. RESULTS: Cumulative incidences of myocardial infarction and ischemic...... heart disease as a function of age increased with increasing levels of creatinine, and survival decreased (log-rank trends: creatinine levels

  4. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  5. Influence of body mass index status on urinary creatinine and specific gravity for epidemiological study of children.

    Science.gov (United States)

    Wang, Bin; Tang, Chuanxi; Wang, Hexing; Zhou, Wei; Chen, Yue; Zhou, Ying; Jiang, Qingwu

    2015-11-01

    In epidemiological studies, urinary biomonitoring is a valid approach to assess the association between environmental chemical exposure and children's health. Many clinical biomarkers (e.g., endogenous metabolites) are also based on analysis of urine. Considering the variability in urinary output, urinary concentrations of chemicals are commonly adjusted by creatinine and specific gravity (SG). However, there is a lack of systematic evaluation of their appropriateness for children. Furthermore, urinary SG and creatinine excretion could be influenced by body mass index (BMI), but the effect of BMI status on the two correction factors is unknown. We measured SG and creatinine concentrations of repeated first morning urine samples collected from 243 primary school children (8-11 years) over 5 consecutive weekdays. Urinary SG presented a higher temporal consistency compared with creatinine. Urinary SG was associated with sex (p creatinine levels. Inter-day collection time was not associated with SG or creatinine after excluding the effect of Monday as a confounder. When stratified by BMI status, none of the factors were associated with creatinine among the overweight and obese children. Generally, SG is preferable for correcting the variability in urinary output for children although creatinine correction may also perform well in overweight and obese children. SG correction is recommended for epidemiological exposure analysis in children based on urinary levels of exogenous or endogenous metabolites.

  6. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  7. Adherence to guidelines for creatinine and potassium monitoring and discontinuation following renin-angiotensin system blockade: a UK general practice-based cohort study.

    Science.gov (United States)

    Schmidt, Morten; Mansfield, Kathryn E; Bhaskaran, Krishnan; Nitsch, Dorothea; Sørensen, Henrik Toft; Smeeth, Liam; Tomlinson, Laurie A

    2017-01-09

    To examine adherence to serum creatinine and potassium monitoring and discontinuation guidelines following initiation of treatment with ACE inhibitors (ACEI) or angiotensin receptor blockers (ARBs); and whether high-risk patients are monitored. A general practice-based cohort study using electronic health records from the UK Clinical Practice Research Datalink and Hospital Episode Statistics. UK primary care, 2004-2014. 223 814 new ACEI/ARB users. Proportion of patients with renal function monitoring before and after ACEI/ARB initiation; creatinine increase ≥30% or potassium levels >6 mmol/L at first follow-up monitoring; and treatment discontinuation after such changes. Using logistic regression models, we also examined patient characteristics associated with these biochemical changes, and with follow-up monitoring within the guideline recommendation of 2 weeks after treatment initiation. 10% of patients had neither baseline nor follow-up monitoring of creatinine within 12 months before and 2 months after initiation of an ACEI/ARB, 28% had monitoring only at baseline, 15% only at follow-up, and 47% both at baseline and follow-up. The median period between the most recent baseline monitoring and drug initiation was 40 days (IQR 12-125 days). 34% of patients had baseline creatinine monitoring within 1 month before initiating therapy, but creatinine increase ≥30% (n=567, 1.2%) or potassium level >6 mmol/L (n=191, 0.4%), 80% continued treatment. Although patients with prior myocardial infarction, hypertension or baseline potassium >5 mmol/L were at high risk of ≥30% increase in creatinine after ACEI/ARB initiation, there was no evidence that they were more frequently monitored. Only one-tenth of patients initiating ACEI/ARB therapy receive the guideline-recommended creatinine monitoring. Moreover, the vast majority of the patients fulfilling postinitiation discontinuation criteria for creatinine and potassium increases continue on treatment

  8. Association of serum lipoprotein (a) with hypertension in diabetic patients

    International Nuclear Information System (INIS)

    Nasri, H.

    2008-01-01

    To evaluate the influence of serum Lp(a) concentration on hypertension in patients with diabetes mellitus (DM) and under treatment with oral hypoglycemic agents or insulin injections, we studied 122 patients, 82 females and 40 males with a mean age of 63+-10 years and duration of DM and HTN of 7.4+-5.8 and 3.2+-4.6 years, respectively. The mean systolic and diastolic blood pressure (BP) was 138+-23 mmHg and 83+-12mmHg, respectively. In this cross-sectional study, we measured serum lipoprotein (a) (Lp(a), glycosilated hemoglobin (HbA1c) and other lipids while the patients were receiving either oral hypoglycemic agents or insulin. In addition, body mass index (BMI) and creatinine clearance (CrCL) were assessed. The mean serum Lp(a) was 22.2+-24.7 mg/dl (median: 18.3 mg/dl), and serum Lp(a) levels >30 mg/dl was found in 29(23.8%) patients. There were significant positive correlations of duration of DM and duration of hypertension, and serum Lp(a) levels with of systoli and diastolic levels of BP. However, a significant inverse correlation of serum Lp(a) with CrCl were observed. This study suggests that kidney function is an independent determination of Lp(a) and HTN in diabetic patients. Furthermore Lp(a) in diabetic patients may have important implications for the increased susceptibility to vascular diseases in these patients. (author)

  9. Association of Serum Lipoprotein (a with Hypertension in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Nasri Hamid

    2008-01-01

    Full Text Available To evaluate the influence of serum Lp(a concentration on hypertension in patients with diabetes mellitus (DM and under treatment with oral hypoglycemic agents or insulin injections, we studied 122 patients, 82 females and 40 males with a mean age of 63 ± 10 years and duration of DM and HTN of 7.4 ± 5.8 and 3.2 ± 4.6 years, respectively. The mean systolic and diastolic blood pressure (BP were 138 ±23 mmHg and 83 ± 12 mmHg, respectively. In this cross-sectional study, we measured serum lipoprotein(a (Lp(a, glycosilated hemoglobine (HbA1c and other lipids while the patients were receiving either oral hypogycemic agents or insulin. In addition, body mass index (BMI and creatinine clearance (CrCL were asessed. The mean serum Lp(a was 22.2 ± 24.7 mg/dl (median: 18.3 mg/dl, and serum Lp(a levels > 30 mg/dl was found in 29 (23.8% patients. There were significant positive correlations of duration of DM and duration of hypertension, and serum Lp(a levels with of systoli and diastolic levels of BP. However, a significant inverse correlation of serum Lp(a with CrCL were observed. This study suggests that kidney function is an independent determinant of Lp(a and HTN in diabetic patients. Furthermore, Lp(a in diabetic patients may have important implications for the increased susceptibility to vascular disease in these patients.

  10. Gold nanoparticles-based colorimetric and visual creatinine assay

    International Nuclear Information System (INIS)

    He, Yi; Zhang, Xianhui; Yu, Haili

    2015-01-01

    We demonstrate a selective and sensitive method for determination of creatinine using citrate-stabilized gold nanoparticles (AuNPs) as a colorimetric probe. It is based on a direct cross-linking reaction that occurs between creatinine and AuNPs that causes aggregation of AuNPs and results in a color change from wine red to blue. The absorption peak is shifted from 520 to 670 nm. Under the optimized conditions, the shift in the absorption peak is related the logarithm of the creatinine concentration in the 0.1 to 20 mM range, and the instrumental detection limit (LOD) is 80 μM. This LOD is about one order of magnitude better than that that of the Jaffé method (720 μM). The assay displays good selectivity over interfering substances including various inorganic ions, organic small compounds, proteins, and biothiols. It was successfully employed to the determination of creatinine in spiked human urine. (author)

  11. 17-Year-Old Boy with Renal Failure and the Highest Reported Creatinine in Pediatric Literature

    Directory of Open Access Journals (Sweden)

    Vimal Master Sankar Raj

    2015-01-01

    Full Text Available The prevalence of chronic kidney disease (CKD is on the rise and constitutes a major health burden across the world. Clinical presentations in early CKD are usually subtle. Awareness of the risk factors for CKD is important for early diagnosis and treatment to slow the progression of disease. We present a case report of a 17-year-old African American male who presented in a life threatening hypertensive emergency with renal failure and the highest reported serum creatinine in a pediatric patient. A brief discussion on CKD criteria, complications, and potential red flags for screening strategies is provided.

  12. The correlates of urinary albumin to creatinine ratio (ACR) in a high risk Australian aboriginal community.

    Science.gov (United States)

    Wang, Zaimin; Hoy, Wendy E; Wang, Zhiqiang

    2013-08-16

    Albuminuria marks renal disease and cardiovascular risk. It was estimated to contribute 75% of the risk of all-cause natural death in one Aboriginal group. The urine albumin/creatinine ratio (ACR) is commonly used as an index of albuminuria. This study aims to examine the associations between demographic factors, anthropometric index, blood pressure, lipid-protein measurements and other biomarkers and albuminuria in a cross-sectional study in a high-risk Australian Aboriginal population. The models will be evaluated for albuminuria at or above the microalbuminuria threshold, and at or above the "overt albuminuria" threshold with the potential to distinguish associations they have in common and those that differ. This was a cross-sectional study of 598 adults aged 18-76 years. All participants were grouped into quartiles by age. Logistic regression models were used to explore the correlates of ACR categories. The significant correlates were systolic blood pressure (SBP), C-reactive protein (CRP), uric acid, diabetes, gamma-glutamyl transferase (GGT) (marginally significant, p=0.054) and serum albumin (negative association) for ACR 17+ (mg/g) for men and 25+ for women. Independent correlates were SBP, uric acid, diabetes, total cholesterol, alanine amino transferase (ALT), Cystatin C and serum albumin (negative association) for overt albuminuria; and SBP, CRP and serum albumin only for microalbuminuria. This is the most detailed modelling of pathologic albuminuria in this setting to date. The somewhat variable association with risk factors suggests that microalbuminuria and overt albuminuria might reflect different as well as shared phenomena.

  13. The effect of acyclovir on the tubular secretion of creatinine in vitro

    Directory of Open Access Journals (Sweden)

    Aleksa Katarina

    2010-12-01

    Full Text Available Abstract Background While generally well tolerated, severe nephrotoxicity has been observed in some children receiving acyclovir. A pronounced elevation in plasma creatinine in the absence of other clinical manifestations of overt nephrotoxicity has been frequently documented. Several drugs have been shown to increase plasma creatinine by inhibiting its renal tubular secretion rather than by decreasing glomerular filtration rate (GFR. Creatinine and acyclovir may be transported by similar tubular transport mechanisms, thus, it is plausible that in some cases, the observed increase in plasma creatinine may be partially due to inhibition of tubular secretion of creatinine, and not solely due to decreased GFR. Our objective was to determine whether acyclovir inhibits the tubular secretion of creatinine. Methods Porcine (LLC-PK1 and human (HK-2 renal proximal tubular cell monolayers cultured on microporous membrane filters were exposed to [2-14C] creatinine (5 μM in the absence or presence of quinidine (1E+03 μM, cimetidine (1E+03 μM or acyclovir (22 - 89 μM in incubation medium. Results Results illustrated that in evident contrast to quinidine, acyclovir did not inhibit creatinine transport in LLC-PK1 and HK-2 cell monolayers. Conclusions The results suggest that acyclovir does not affect the renal tubular handling of creatinine, and hence, the pronounced, transient increase in plasma creatinine is due to decreased GFR, and not to a spurious increase in plasma creatinine.

  14. Plasma creatinine levels, estimated glomerular filtration rate and carotid intima media thickness in middle-aged women: a population based cohort study.

    Science.gov (United States)

    Gentile, M; Panico, S; Mattiello, A; de Michele, M; Iannuzzi, A; Jossa, F; Marotta, G; Rubba, P

    2014-06-01

    The relationships between high Creatinine (Cr) levels or low estimated Glomerular Filtration Rate (eGFR) and common carotid Intima Media thickness (IMT) have been evaluated in a population-based cohort study in women, aged 30-69 (Progetto ATENA). Serum Cr and eGFR were measured in 310 women, as a part of 5.062. In this group carotid ultrasound examination (B-Mode imaging) was performed and mean max IMT was calculated. Women were classified by Cr levels >1 mg/dL or eGFR Women with Cr > 1 mg/dL (90th percentile of creatinine distribution) or eGFR less than 56 ml/min (5th percentile of eGFR distribution) had relatively more carotid plaques as compared to the rest of the cohort. Multivariate logistic analysis, after adjustment for age, demonstrated a significant association between Cr (>1 mg/dL) and IMT (≥1.2 mm): OR 4.12 (C.I 1.22-13.86), p = 0.022; or eGFR (women, independently of age, suggest the value of screening for early carotid disease in asymptomatic middle aged-women with mild renal insufficiency, in order to predict those at relatively higher risk for future cardiovascular events. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Weights, hematology and serum chemistry of free-ranging brown boobies (Sula leucogaster) in Johnston Atoll, Central Pacific

    Science.gov (United States)

    Work, Thierry M.

    1999-01-01

    Hematologic and serum chemistry values are reported for 105 brown boobies (Sula leucogaster) from Johnston Atoll, Central Pacific. Hematocrit, estimated total plasma solids, total and differential white cell counts, serum glucose, calcium, phosphorus, uric acid, total protein, albumin, globulin, aspartate aminotransferase, and creatinine phosphokinase were analyzed. Hematologic and serum chemistry values varied with age and sex. Values were compared with those of red-footed boobies and other tropical and temperate marine pelecaniforms.

  16. Cause-Specific Mortality According to Urine Albumin Creatinine Ratio in the General Population

    DEFF Research Database (Denmark)

    Skaaby, Tea; Husemoen, Lise Lotte Nystrup; Ahluwalia, Tarun Veer Singh

    2014-01-01

    BACKGROUND: Urine albumin creatinine ratio, UACR, is positively associated with all-cause mortality, cardiovascular disease and diabetes in observational studies. Whether a high UACR is also associated with other causes of death is unclear. We investigated the association between UACR and cause......-specific mortality. METHODS: We included a total of 9,125 individuals from two population-based studies, Monica10 and Inter99, conducted in 1993-94 and 1999-2001, respectively. Urine albumin creatinine ratio was measured from spot urine samples by standard methods. Information on causes of death was obtained from...

  17. Serum Levels of Progranulin Are Closely Associated with Microvascular Complication in Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Lin Xu

    2015-01-01

    Full Text Available Objective. Progranulin (PGRN was recently introduced as a novel marker of chronic inflammatory response in obesity and type 2 diabetes capable of directly affecting the insulin signaling pathway. This study aimed to investigate the correlation between PGRN and type 2 diabetics with microvascular complications. Methods. PGRN serum levels and glucose metabolism related substance were measured in 84 type 2 diabetic patients with or without microangiopathies and 12 health persons. Further analyses of serum PGRN in different stages of diabetic microangiopathies were conducted. Results. Serum levels of PGRN were markedly higher in type 2 diabetic patients with microangiopathies. PGRN serum levels increased with the progress of diabetic microangiopathies with significantly highest values detectable in clinical diabetic nephropathy (CDN and proliferative diabetic retinopathy (PDR groups. Serum PGRN concentrations in all individuals positively and markedly correlated with systolic blood pressure (SBP, diastolic blood pressure (DBP, body mass index (BMI, triglyceride (TG, urinary albumin excretion rate (UAER, blood urea nitrogen (BUN, creatinine (CRE, white blood cell (WBC, disease duration, IL-6, and TNF-α, while correlating negatively and significantly with eGFR. Multiple linear regression analysis showed that only UAER and CRE were independently associated with serum PGRN. Conclusion. PGRN might be considered as a marker for diabetic microangiopathy and its severity.

  18. Interferences of homogentisic acid (HGA) on routine clinical chemistry assays in serum and urine and the implications for biochemical monitoring of patients with alkaptonuria.

    Science.gov (United States)

    Curtis, S L; Roberts, N B; Ranganath, L R

    2014-05-01

    We have assessed the effect of elevated concentrations of homogentisic acid (HGA) as in alkaptonuria (AKU), on a range of routine chemistry tests in serum and urine. HGA was added to pooled serum and a range of assays was analysed with Roche Modular chemistries. Effects on urine were assessed by diluting normal urine with urine from a patient with AKU, adding HGA to urine and after lowering output of urinary HGA with nitisinone treatment. Serum enzymatic creatinine showed 30% negative interference with 100μmol/L HGA and >50% at 400μmol/L. Serum urate 100 to 480μmol/L was reduced up to 20% at 100 and to 50% with 400μmol/L HGA. Serum cholesterol between 3 and 11mmol/L was reduced by 0.5mmol/L with 400μmol/L HGA. Urine enzymatic creatinine and urate with >2mmol/L HGA showed concentration dependent negative interference up to 80%. A positive interference in urine total protein by benzethonium turbidometric assay was observed, with 10mmol/L HGA equivalent to 1g/L protein. Jaffe creatinine, Na, K, Cl, Mg, Ca, phosphate, ALT, GGT, ALP activities and urea in serum and or urine were not affected by increases in HGA. To avoid interferences by HGA in alkaptonuria concentration of HGA should be established before samples are assayed with peroxidase assays and benzethonium urine protein. Copyright © 2013 The Canadian Society of Clinical Chemists. All rights reserved.

  19. Biodistribution of 99m technetium labeled creatinine in healthy rats

    International Nuclear Information System (INIS)

    Yilmaz, O.; Soylu, A.; Kavukcu, S.; Lambrecht, F. Yurt; Durkan, K.

    2007-01-01

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with 99m technetium ( 99m Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 ± 2% under optimum conditions (pH 7 and 100 μg stannous chloride). Rats (N 12) were injected intravenously with 99m Tc creatinine and their blood and visceral organs were evaluated for 99m Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of 99m Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  20. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    Science.gov (United States)

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P creatinine concentrations were significantly lower in the R vs. L group (Pcreatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Analytical nanosphere sensors using quantum dot-enzyme conjugates for urea and creatinine.

    Science.gov (United States)

    Ruedas-Rama, Maria J; Hall, Elizabeth A H

    2010-11-01

    An enzyme-linked analytical nanosphere sensor (ANSor) is described, responding to enzyme-substrate turnover in the vicinity of a quantum dot (QD) due to coimmobilized enzyme and pH sensitive ligand. QD capping by mercapto-alkanoic acids were rejected as a pH sensitive ligand, but with the use of a layer-by-layer assembly on mercaptopropionic capped QDs and an intermediate poly(allylamine hydrochloride) layer, anthraquinone sulfonate (calcium red, CaR) was introduced to modify the pKa in the immobilized system > 8. QD-CaR absorption shows spectral overlap with QD530 emission at all pHs and gives a complex pH dependent fluorescence resonance energy transfer (FRET) efficiency, due to excited state proton transfer (λ(ex) = 540 nm; λ(em) = 585 nm). In contrast QD615-CaR with spectral overlap between the QD and CaR gave a strong and reproducible pH response. QD-urease and QD-creatinine deiminase conjugates could be linked with pH changes produced by enzyme degradation of urea and creatinine, respectively. Close coupling between the pH sensitive QD and enzyme conjugate maximized signal compared with solution based assays: QD-urease and QD-CD bioconjugates were tested in model biological media (Dulbecco's modified Eagle's Medium and fetal calf serum) and in urine, showing a response in 3-4 min.

  2. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    Science.gov (United States)

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  3. Two novel creatinine adducts of andrographolide in human urine.

    Science.gov (United States)

    Qiu, Feng; Cui, Liang; Chen, Lixia; Sun, Jiawen; Yao, Xinsheng

    2012-09-01

    Andrographolide is a major labdane diterpenoid of the traditional Chinese and Ayurvedic medicine. Andrographis paniculate (Burm) Nees, is used in clinical situations in China mainly to treat fever, cold, and inflammation. In our previous study, fifteen metabolites of andrographolide were identified in human urine. However, there are still two other unknown metabolites. The aim of this study was to elucidate the structures of these two metabolites. 3. The two metabolites which are probably epimers were identified as creatinine adducts, and their structures were determined to be 14-deoxy-12-(creatinine-5-yl)-andrographolide-19-O-β-D-glucuronide A (Metabolite 1) and 14-deoxy-12-(creatinine-5-yl)-andrographolide-19-O-β-D-glucuronide B (Metabolite 2) by means of spectroscopic evidences. 4. It is for the first time that the formation of creatinine adducts as a novel metabolic pathway is reported. The mechanism was presumed that β-carbon (C-12) of α, β-unsaturated carbonyl was attacked by a 5-anion intermediate of creatinine formed through elimination of a proton, followed by the double bond migration from 12(13) to 13(14) and elimination of the hydroxyl group at C-14.

  4. Creatinine concentrations of accumulated intrauterine fluid to confirm the clinical diagnosis of urometra in mares.

    Science.gov (United States)

    Schnobrich, M R; Gordon, D L; Scoggin, C F; Bradecamp, E A; Canisso, I F

    2017-03-25

    Urine pooling, as a persistent condition, is a cause of infertility in mares due to endometrial inflammation and sperm toxicity. Identification of urometra can be challenging in mares presenting with the condition intermittently, or when urine flows into the uterus but is undetectable in the vagina. Currently, there are no reported objective methods to confirm the clinical diagnosis of urine contamination in intrauterine-fluid accumulations. Since creatinine is present in high concentrations in urine and does not diffuse across cell membranes, creatinine concentration should be increased in mares with urometra, but negligible in normal and mares with intrauterine fluid accumulation (non-urometra cases). To test this hypothesis, creatinine concentrations of intrauterine fluid were measured in mares with a clinical diagnosis of urine accumulation (n=9) or intrauterine fluid containing no urine (n=10). Results showed that creatinine concentrations (mg/dl) were significantly higher in mares that had a clinical diagnosis of urometra (42.8±12.6, range 4.1-109.2) compared with those that did not (0.38±0.1, range 0-0.9). Also, two mares after urethral extension surgery demonstrated a remarkable reduction in creatinine concentrations. This study highlights an undocumented approach to confirm a clinical diagnosis of urometra in mares; the authors anticipate that testing for creatinine in the uterine fluid of mares may become a standard tool for identifying urometra in mares and confirming the success of urogenital surgeries. British Veterinary Association.

  5. Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction-Measurement by ELISA.

    Directory of Open Access Journals (Sweden)

    Shozo Yokoyama

    Full Text Available Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA.One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH. Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay.A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference and the addition of bovine serum albumin (BSA resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA.We optimized an easy and rapid detection method for assessment of

  6. Radioimmunoassay for measurement of thyroxine (T4) and triiodothyonine (T3) in blood serum

    International Nuclear Information System (INIS)

    Chopra, I.J.

    1975-01-01

    This invention relates to a highly accurate, rapid and simple estimation of thyroxine (T 4 ) directly from blood serum and also relates to the accurate measurement of triiodo-L-thyronine (T 3 ) directly from blood serum. More specifically, the invention relates to a rapid, specific and reliable radioimmunoassay (RIA) technique for measurement of both T 4 and T 3 in unextracted serum. The method requires very small amounts of serum, e.g., 25 microliters (μl) to measure T 4 concentration in nearly all specimens representing clinical states of eu-, hypo- and hyperthyroidism, and 250 μl to measure T 3 concentrations in specimens representing most clinical states

  7. Sensitivitas dan Spesifisitas Cystatin C dan Kreatinin Serum dalam Mendiagnosis Cedera Ginjal Akut pada Pasien Sepsis yang Dirawat di Ruang Rawat Intensif RSUP H. Adam Malik Medan

    Directory of Open Access Journals (Sweden)

    Hasanul Arifin

    2016-08-01

    Full Text Available Serum creatinine has many limitations when being used to diagnose acute kidney injury (AKI, especially in the scope of intensive care unit due to its low sensitivity to depict the kidney dysfunctional level of critically-ill patients. Out of numerous new available biological markers, four biological markers are widely used all over the world to detect AKI, e.g. neutrophil gelatinase-associated lipocalin (NGAL, cystatin C, KIM-1, and interleukin-18. The purpose of this study was to determine the sensitivity and specificity of serum cystatin C and creatinine in establishing the diagnosis of acute kidney injury in sepsis patients treated in intensive care room. This study was a diagnostic test to 24 patients and conducted in intensive care room of H. Adam Malik Hospital during the period of February–March 2014. Population in this study is all adult patients with sepsis, severe sepsis, and septic shock in the intensive care room. A statistical test was conducted using receiving operator characteristics (ROC method using SPSS 17 software. The result of this study showed that serum cystatin C was more superior than serum creatinine in detecting acute kidney injury in sepsis patients treated in intensive care room. In this study, cystatin C had higher sensitivity, positive prediction score, negative prediction score, and area under curve-receiving operator characteristics (AUC-ROC than serum creatinine. As of specificity, there was no significant difference between these two biological markers. In conclusion, cystatin C can be an alternative biological marker to detect AKI in sepsis patients treated in intensive care room with a better diagnostic value.

  8. Comparison of 24-hour urinary protein and protein-to-creatinine ratio in the assessment of proteinuria

    International Nuclear Information System (INIS)

    Wahbeh, Ayman M; Ewais, Mohammad H; Elsharif, Mahamed E

    2009-01-01

    To determine the correlation between protein-to-creatinine ratio (PCR) and 24-hour urinary protein (UP), we measured proteinuria in 68 patients attending the nephrology clinic at Jordan University Hospital by 24-hour urine protein excretion and protein-to-creatinine ratio. The cutoff values for spot urine protein-to-creatinine ratio in predicting 24-hour protein 'threshold' excretion of 0.5, 1.0 and 3.5 g/day were determined using receiver operating characteristic curves. A very good correlation (r= 0.832, P< 0.0001) was found between spot urine protein-to-creatinine ratio and 24-hour urine protein excretion. Bland-Altman plot showed the two tests had reasonable limits of agreement at low level of protein excretion but the limits became wider as the protein excretion increased. For protein excretion < 2.0 g/day, the limits of agreement of spot urine (PCR) and (UP) were +1.48 and -1.2 g/day. The spot urine protein-to-creatinine ratios of 0.72 (sensitivity 0.97; specificity 1.0), 1.2 (0.97; 0.89) and 3.23 (1.0; 0.86) mg/mg reliably predicted 24-hour urine total protein equivalent 'thresholds' of 0.5, 1.0 and 3.5 g/day, respectively. We conclude that the protein-to-creatinine ratio in spot urine specimens is an accurate, convenient, and reliable method to estimate the protein excretion in urine. However, the protein-to-creatinine ratio will likely be within clinically acceptable limits only when proteinuria is at reasonably low levels. (author)

  9. Effect of tetrastarch (hydroxyethyl starch 130/0.4) on plasma creatinine concentration in cats: a retrospective analysis (2010-2015).

    Science.gov (United States)

    Yozova, Ivayla D; Howard, Judith; Adamik, Katja N

    2017-10-01

    Objectives The objective was to determine survival and changes in creatinine concentrations after administration of 6% tetrastarch (hydroxyethyl starch [HES] 130/0.4) vs crystalloids in critically ill cats. Methods The medical records were reviewed for cats admitted to the intensive care unit with at least two plasma creatinine measurements and initial concentrations not exceeding the upper reference interval. Cats were excluded if they had received HES prior to admission or if they had received fluid therapy for creatinine concentrations were evaluated as the percentage change from initial values to the maximum subsequent measurements. Cats receiving only crystalloids were assigned to the crystalloid group; cats receiving only HES or HES and crystalloids were assigned to the HES group. Results Ninety-three cats were included in the study (62 in the crystalloid group, 31 in the HES group). The total median cumulative HES dose was 94 ml/kg (range 26-422 ml/kg) and 24 ml/kg/day (range 16-42 ml/kg/day). No difference was detected between the groups for age, sex, body weight or mortality. The HES group had a significantly longer length of hospitalisation ( P = 0.012), lower albumin concentrations ( P creatinine concentrations between the groups. Moreover, there was no significant difference in maximum change in creatinine concentrations in the subgroups of cats with systemic inflammatory response syndrome or sepsis. Conclusions and relevance In this population of cats, the administration of HES did not result in a significantly greater increase in creatinine from values measured on admission or higher mortality compared with administration of crystalloids. Further prospective studies are needed to assess both safety and efficacy of HES in cats before recommendations can be made.

  10. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    International Nuclear Information System (INIS)

    Schuettler, J.; White, P.F.

    1984-01-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories

  11. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, J.; White, P.F.

    1984-09-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.

  12. Optimal Fasting Time before Measurement of Serum Triglyceride Levels in Healthy Volunteers.

    Science.gov (United States)

    Pongsuthana, Surapun; Tivatunsakul, Naris

    2016-02-01

    Coronary heart disease is a major public health problem. Elevated triglyceride levels are a risk factor for atherosclerosis and coronary heart disease. Food intake interferes with the measurement of serum triglyceride levels, and in previous studies, fasting for 12 hours was recommended before blood sampling. In real-world practice, long fasting times cause patient discomfort and poor compliance, and the present study was, therefore, designed to determine the appropriate fasting time prior to measuring serum triglyceride levels. To determine the appropriate fasting time before measuring serum triglyceride levels. This was a pilot study performed using healthy volunteers aged between 20 and 30 years old from November 2013 to December 2013 at Rajavithi Hospital. The first blood sample was measured in the morning after fasting over 12 hours. The subjects then took their regular breakfast, after which they fasted for 8 hours. Blood samples were taken 6 and 8 hours later and sent to the laboratory for measurement of serum triglyceride levels. 40 volunteers, of whom 25 were female, were enrolled. Their mean age was 25.9 ± 2.81 years old, and their mean weight, height, and body mass index were 61.5 ± 12.5 kg, 167.2 ± 8.3 cm and 21.84 ± 3.1 kg/m2, respectively. Mean fasting serum triglyceride level at 12 hours was 80.23 ± 36.33 mg/dl, at 6 hours it was 110.65 ± 73.45 mg/dl, and at 8 hours it was 75.62 ± 46.81 mg/dl. The group fasting for 12 hours had significantly lower serum triglyceride levels than the group fasting for 6 hours (p-value = 0.003), but no significant difference was found between the group fasting for 12 hours and the one fasting for 8 hours (p-value = 0.493). The present study showed no significant difference in triglyceride levels in patients who had fasted or 8 hours and those who had done so for 12 hours. Fasting for only 8 hours before measurement of serum triglyceride may be sufficient.

  13. DETERMINING URINARY CREATININE BY ALKALINE PICRATE METHOD AND HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    OpenAIRE

    戎, 利光; 目, 不二雄; 菅原, 泰一

    1986-01-01

    Urinary creatinine has been widely analyzed in research fields concerning body composition and muscular activities since the amount of creatinine excretion in urine is nearly proportional to the muscular mass in humans, and the amount in an individual is nearly constant. And also research studies pointed out the decrease in urinary creatinine after acute exercise. Effects of exercise upon urinary creatinine have been, furthermore, reported. However, there are research studies indicating that ...

  14. Advances in bioanalytical techniques to measure steroid hormones in serum.

    Science.gov (United States)

    French, Deborah

    2016-06-01

    Steroid hormones are measured clinically to determine if a patient has a pathological process occurring in the adrenal gland, or other hormone responsive organs. They are very similar in structure making them analytically challenging to measure. Additionally, these hormones have vast concentration differences in human serum adding to the measurement complexity. GC-MS was the gold standard methodology used to measure steroid hormones clinically, followed by radioimmunoassay, but that was replaced by immunoassay due to ease of use. LC-MS/MS has now become a popular alternative owing to simplified sample preparation than for GC-MS and increased specificity and sensitivity over immunoassay. This review will discuss these methodologies and some new developments that could simplify and improve steroid hormone analysis in serum.

  15. Relationship between changes of serum leptin levels and degree of glomerulosclerosis in rats after 5/6 nephrectomy

    International Nuclear Information System (INIS)

    Yang Licai; Zhang Daoyou; Zhu Xinjian; Wang Yuwei; Gao Chaoqing; Xu Haihong

    2006-01-01

    Objective: To investigate the relationship between changes of serum leptin levels and glomerulosclerosis index, TGF-β 1 expression at glomerulus as well as degree of ECM proliferation in rats after 5/6 nephrectomy. Methods: Eight rats underwent two-stage 5/6 nephrectomy to establish a progressive glomeruloselerosis model. Six weeks after the second operation, the rats were sacrificed, the renal tissue was examined with routine pathological sections for study of glomerulosclerosis as well as with immunohistochemical studies for TGF-β 1 , collagen IV and fibronectin expressions. Six rats underwent sham operation served as controls. Serum creatinine, urea nitrogen and leptin levels were measured in all these animals. Results: The serum levels of leptin were significantly higher in rats after 5/6 nephrectomy than the rats with sham operations (14.88 ± 1.46ng/ml vs 10.84 ± 2.67ng/ml, P < 0. 01 ). Serum levels of leptin were positively correlated with the glomeruloselerosis index and collagen IV, fibronectin expressions ( P < 0.01 ). Conclusion: Hyperleptinemia may be one of the causative factors of development of glomerulosclerosis. (authors)

  16. Development of a quick serum IL-6 measuring system in rheumatoid arthritis.

    Science.gov (United States)

    Koyama, Kensuke; Ohba, Tetsuro; Ishii, Kentaro; Jung, Giman; Haro, Hirotaka; Matsuda, Kenichi

    2017-07-01

    Interleukin-6 (IL-6) plays a crucial role in the pathogenesis of rheumatoid arthritis (RA). Both fulfillment of remission criteria and assessment of other methods of evaluation of RA are important for preventing joint damage progression. Measurement of serum IL-6 concentrations has been reported to be useful for monitoring RA disease activity. However, it takes at least 4-5h to measure serum IL-6 concentrations using traditional methods, which limits its utility during routine assessment in daily clinical practice settings. We established a novel method that enables measurement of serum IL-6 within 24min and requires a very small blood volume. We investigated the accuracy and efficacy of this system in RA patients. One hundred fifty blood samples collected from 76 patients were measured using the two systems. We first developed the prototype of the Human IL-6 RAYFAST. Then, we examined the correlation between the prototype RAYFAST and chemiluminescent enzyme immunoassay (CLEIA) methods. Finally, we compared IL-6 concentrations and clinical parameters using both systems. The correlation between RAYFAST (x) and CLEIA (y) for IL-6 was y=0.895x-5.94, r=0.941 (p<0.0001). Serum IL-6 concentrations in RAYFAST correlated with DAS28-CRP (r=0.372, p<0.05) and DAS28-ESR (r=0.397, p<0.01). Serum IL-6 concentrations in CLEIA correlated with DAS28-CRP (r=0.313, p<0.001) and DAS28-ESR (r=0.353, p<0.001). This new cytokine quick measure system is as accurate as CLEIA methods. Serum IL-6 concentrations can be measured in 24min using the prototype RAYFAST. It might be usable in the daily clinical practice setting, thereby contributing to improved RA management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Testosterone replacement elevates the serum uric acid levels in patients with female to male gender identity disorder.

    Science.gov (United States)

    Kurahashi, Hiroaki; Watanabe, Masami; Sugimoto, Morito; Ariyoshi, Yuichi; Mahmood, Sabina; Araki, Motoo; Ishii, Kazushi; Nasu, Yasutomo; Nagai, Atsushi; Kumon, Hiromi

    2013-01-01

    Gender identity disorder (GID) results from a disagreement between a person's biological sex and the gender to which he or she identifies. With respect to the treatment of female to male GID, testosterone replacement therapy (TRT) is available. The uric acid (UA) level can be influenced by testosterone; however, the early effects and dose-dependency of TRT on the serum UA concentration have not been evaluated in this population. We herein conducted a dose-response analysis of TRT in 160 patients with female to male GID. The TRT consisted of three treatment groups who received intramuscular injections of testosterone enanthate: 125 mg every two weeks, 250 mg every three weeks and 250 mg every two weeks. Consequently, serum UA elevation was observed after three months of TRT and there was a tendency toward testosterone dose-dependency. The onset of hyperuricemia was more prevalent in the group who received the higher dose. We also demonstrated a positive correlation between increased levels of serum UA and serum creatinine. Since the level of serum creatinine represents an individual's muscle volume and the muscle is a major source of purine, which induces UA upregulation, the serum UA elevation observed during TRT is at least partially attributed to an increase in muscle mass. This is the first study showing an association between serum UA elevation and a TRT-induced increase in muscle mass. The current study provides important information regarding TRT for the follow-up and management of the serum UA levels in GID patients.

  18. Stability of creatinine and cystatin C in whole blood

    NARCIS (Netherlands)

    Spithoven, E. M.; Bakker, S. J. L.; Kootstra-Ros, J.E.; de Jong, P. E.; Gansevoort, R. T.

    2013-01-01

    Background: As yet little is known about the effect of delayed separation of whole blood stored at room temperature on the stability of the kidney function markers creatinine and cystatin C. Methods: We used plasma samples of 45 patients with a wide range of creatinine and cystatin C concentration.

  19. Increasing the sensitivity of the Jaffe reaction for creatinine

    Science.gov (United States)

    Tom, H. Y.

    1973-01-01

    Study of analytical procedure has revealed that linearity of creatinine calibration curve can be extended by using 0.03 molar picric acid solution made up in 70 percent ethanol instead of water. Three to five times more creatinine concentration can be encompassed within linear portion of calibration curve.

  20. The effects of cimetidine on creatinine excretion, glomerular filtration rate and tubular function in renal transplant recipients

    DEFF Research Database (Denmark)

    Olsen, N V; Ladefoged, S D; Feldt-Rasmussen, B

    1989-01-01

    The renal clearance of endogenous creatinine (CCr), sodium (CNa) and lithium (CLi) was determined before and after a single intravenous bolus of cimetidine in nine renal transplant recipients. The glomerular filtration rate (GFR) was measured with 125I-iothalamate clearance (CTh). The initial CCr...... of 65 ml/min (median) was reduced to a nadir of 46 ml/min (p less than 0.01) during the first 2 h after infusion of cimetidine. GFR remained unchanged, and thus the fractional clearance of creatinine (CCr/CTh) was reduced from 1.43 (median) to 1.03 (p less than 0.01). CNa and the fractional excretion...... of sodium decreased throughout the study (p less than 0.05); CLi was unchanged. In conclusion cimetidine, when measured during 1-h clearance periods, interferes with tubular creatinine secretion in the denervated kidney of transplant recipients without affecting the glomerular filtration rate or proximal...

  1. Biodistribution of {sup 99m} technetium labeled creatinine in healthy rats

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, O. [Dokuz Eylul University, Narlidere, Izmir (Turkey). Medical Faculty. Dept. of Animal Research Center; Soylu, A.; Kavukcu, S. [Dokuz Eylul University, Narlidere, Izmir (Turkey). Medical Faculty. Dept. of Pediatrics; Lambrecht, F. Yurt; Durkan, K. [Ege University, Bornova, Izmir (Turkey). Institute of Nuclear Sciences. Dept. of Nuclear Applications]. E-mail: s.kavukcu@deu.edu.tr

    2007-06-15

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with {sup 99m}technetium ({sup 99m} Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 {+-} 2% under optimum conditions (pH 7 and 100 {mu}g stannous chloride). Rats (N 12) were injected intravenously with {sup 99m} Tc creatinine and their blood and visceral organs were evaluated for {sup 99m} Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of {sup 99m} Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  2. Serum bone alkaline phosphatase and calcaneus bone density predict fractures: a prospective study.

    Science.gov (United States)

    Ross, P D; Kress, B C; Parson, R E; Wasnich, R D; Armour, K A; Mizrahi, I A

    2000-01-01

    The aim of this study was to assess the ability of serum bone-specific alkaline phosphatase (bone ALP), creatinine-corrected urinary collagen crosslinks (CTx) and calcaneus bone mineral density (BMD) to identify postmenopausal women who have an increased risk of osteoporotic fractures. Calcaneus BMD and biochemical markers of bone turnover (serum bone ALP and urinary CTx) were measured in 512 community-dwelling postmenopausal women (mean age at baseline 69 years) participating in the Hawaii Osteoporosis Study. New spine and nonspine fractures subsequent to the BMD and biochemical bone markers measurements were recorded over an average of 2.7 years. Lateral spinal radiographs were used to identify spine fractures. Nonspine fractures were identified by self-report at the time of each examination. During the 2.7-year follow-up, at least one osteoporotic fracture occurred in 55 (10.7%) of the 512 women. Mean baseline serum bone ALP and urinary CTx were significantly higher among women who experienced an osteoporotic fracture compared with those women who did not fracture. In separate age-adjusted logistic regression models, serum bone ALP, urinary CTx and calcaneus BMD were each significantly associated with new fractures (odds ratios of 1.53, 1.54 and 1.61 per SD, respectively). Multiple variable logistic regression analysis identified BMD and serum bone ALP as significant predictors of fracture (p = 0.002 and 0.017, respectively). The results from this investigation indicate that increased bone turnover is significantly associated with an increased risk of osteoporotic fracture in postmenopausal women. This association is similar in magnitude and independent of that observed for BMD.

  3. FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

    Science.gov (United States)

    Bruno, John G.

    2013-01-01

    Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is

  4. Comparing Serum and 24-hour Urine Calcium between Preeclamptic and Non-preeclamptic Patients

    Directory of Open Access Journals (Sweden)

    N Shahbazian

    2014-02-01

    Results: No statistically significant difference was found between serum calcium means in the two groups (p=0.07, though mean of 24-hour urine calcium in preeclamptic patients was significantly lower than that of control group (p=0.0003. In preeclamptic group, the degree of hypocalciuria was related to disordered liver enzymes, serum creatinine greater than 1.2 mg/dl, thrombocytopenia and proteinuria more than 2g/24h. Conclusion: Preeclampsia is associated with hypocalciuria; the more hypocalciuria there exists , the more preeclampsia is observed.

  5. Identification and measurement of a folate-binding protein in human serum by radioimmunoassay

    International Nuclear Information System (INIS)

    Da Costa, M.; Rothenberg, S.P.; Fischer, C.; Rosenberg, Z.

    1978-01-01

    Antiserum raised in rabbits against the FBP obtained from CML cells, and the purified binder labeled with 125 I, have been used for an RIA which can measure an immunologically similar protein in human serum. The concentration of the binding protein in normal serums ranged from 1.2 to 9.3 ng/ml, with a mean +- S.E.M. of 3.8 +- 0.4 ng/ml. Elevated values of the binder protein were measured in the serums from patients with folate deficiency, vitamin B 12 deficiency, liver disease, uremia, myeloproliferative diseases, chronic lymphocytic leukemia, and various types of cancer and in the serum from pregnant women. The concentration of the binder protein and the capacity of the serum to specifically bind isotopically labeled PGA correlated poorly, indicating that the binding protein concentration and degree of saturation by endogenous serum folate vary independently in many instances

  6. Ionized calcium serum evaluation in unilateral thyroidectomized cats

    Directory of Open Access Journals (Sweden)

    Katia Barão Corgozinho

    2015-12-01

    Full Text Available ABSTRACT. Corgozinho K.B., Cunha S.C.S., Neves A.P., Belchior C., Damico C.B., Silva C.A., Souza H.J.M.& Ferreira A.M.R. [Ionized calcium serum evaluation in unilateral thyroidectomized cats.] Avaliação do cálcio ionizado em gatos submetidos a tireoidectomia unilateral. Revista Brasileira de Medicina Veterinária 37(4:345-349, 2015. Pós-Graduação em Clínica e Reprodução Animal, Faculdade de Veterinária, Universidade Federal Fluminense, Rua Vital Brasil Filho, 64, Niterói, RJ 24230-340, Brasil. E-mail: katia.barao@gmail.com Seventeen hyperthyroid cats with cervical palpable nodules were submitted to clinical and laboratorial examination and they were prepared to surgery. Unilateral thyroparathyroidectomy with parathyroid gland autotransplantation was performed. Concentrations of serum urea, creatinine, alkaline phosphatase, alanine aminotransferase, phosphorus, potassium, total thyroxine and hematologic profile were determined before and seven days after surgery. Blood samples for serum ionized calcium concentration were collected before and after surgery on days 1, 2, 7, 15, 21. All cats had ionized calcium concentration within the reference range before surgery. Serum calcium concentration fell significantly in all cats within 24 hours after surgery. Hypocalcemia occurred in two cats without clinical signs. Ionized calcium concentration decreased after surgery and returned to normal levels on day 7 postoperatively. The results of this study suggest that calcium concentration must be measured before surgery in cats submitted to thyroidectomy even if they are submitted to unilateral technique.

  7. Body Mass Index Is Associated with Increased Creatinine Clearance by a Mechanism Independent of Body Fat Distribution

    Science.gov (United States)

    Gerchman, Fernando; Tong, Jenny; Utzschneider, Kristina M.; Zraika, Sakeneh; Udayasankar, Jayalakshmi; McNeely, Marguerite J.; Carr, Darcy B.; Leonetti, Donna L.; Young, Bessie A.; de Boer, Ian H.; Boyko, Edward J.; Fujimoto, Wilfred Y.; Kahn, Steven E.

    2009-01-01

    Context: Although obesity has been, in general, associated with glomerular hyperfiltration, visceral adiposity has been suggested to be associated with reduced glomerular filtration. Objective: The aim of the study was to evaluate the differential effects of obesity and body fat distribution on glomerular filtration. Design and Setting: We conducted a cross-sectional study of the Japanese-American community in Seattle, Washington. Participants: We studied a representative sample of second-generation Japanese-American men and women with normal glucose tolerance (n = 124) and impaired glucose metabolism (impaired fasting glucose and/or impaired glucose tolerance) (n = 144) residing in King County, Washington. Main Outcome Measures: Glomerular filtration rate was estimated by 24-h urinary creatinine clearance, body size by body mass index (BMI), and intra-abdominal fat (IAF), sc fat (SCF), and lean thigh areas by CT scan. Results: Creatinine clearance was positively correlated with BMI (r = 0.429; P creatinine clearance and BMI remained significant after adjustments for IAF, SCF areas, and fasting insulin levels (r = 0.337; P creatinine clearance after adjusting for BMI. Creatinine clearance increased with increasing BMI after adjusting for fasting insulin, fasting glucose, IAF and SCF areas in subjects with normal glucose tolerance (r = 0.432; P metabolism (r = 0.471; P creatinine clearance in nondiabetic subjects. Lean body mass, rather than adiposity, may explain this association. PMID:19584179

  8. Serum biochemistry and morbidity among runners presenting for medical care after an Australian mountain ultramarathon.

    Science.gov (United States)

    Reid, Stephen A; King, M Jonathan

    2007-07-01

    To determine if exercise-associated hyponatremia (EAH) was a cause of morbidity among runners requiring medical care at an Australian mountain ultramarathon. Case series. Six Foot Track mountain ultramarathon, New South Wales, Australia, March 2006. Runners presenting to the medical facility. Serum biochemistry. No cases of exercise-associated hyponatremia were identified among 9 athletes (from 775 starters) who were treated with intravenous fluid therapy. Unwell runners had a mean serum (Na) of 143 mmol/L (range 138-147 mmol/L). All runners tested had elevated serum urea and creatinine concentrations. In this setting, EAH was not a significant cause of morbidity.

  9. Serum resistin is associated with the severity of microangiopathies in type 2 diabetes

    International Nuclear Information System (INIS)

    Osawa, Haruhiko; Ochi, Masaaki; Kato, Kenichi; Yamauchi, Junko; Nishida, Wataru; Takata, Yasunori; Kawamura, Ryoichi; Onuma, Hiroshi; Takasuka, Tomomi; Shimizu, Ikki; Fujii, Yasuhisa; Ohashi, Jun; Makino, Hideichi

    2007-01-01

    Resistin, secreted from adipocytes, causes insulin resistance and diabetes in rodents. To determine the relation between serum resistin and diabetic microangiopathies in humans, we analyzed 238 Japanese T2DM subjects. Mean serum resistin was higher in subjects with either advanced retinopathy (preproliferative or proliferative) (P = 0.0130), advanced nephropathy (stage III or IV) (P = 0.0151), or neuropathy (P = 0.0013). Simple regression analysis showed that serum resistin was positively correlated with retinopathy stage (P = 0.0212), nephropathy stage (P = 0.0052), and neuropathy (P = 0.0013). Multiple regression analysis adjusted for age, gender, and BMI, revealed that serum resistin was correlated with retinopathy stage (P = 0.0144), nephropathy stage (P = 0.0111), and neuropathy (P = 0.0053). Serum resistin was positively correlated with the number of advanced microangiopathies, independent of age, gender, BMI, and either the duration of T2DM (P = 0.0318) or serum creatinine (P = 0.0092). Therefore, serum resistin was positively correlated with the severity of microangiopathies in T2DM

  10. Serum lipids, recent suicide attempt and recent suicide status in patients with major depressive disorder.

    Science.gov (United States)

    Baek, Ji Hyun; Kang, Eun-Suk; Fava, Maurizio; Mischoulon, David; Nierenberg, Andrew A; Yu, Bum-Hee; Lee, Dongsoo; Jeon, Hong Jin

    2014-06-03

    Major depressive disorder (MDD) is associated with suicide. Although several studies have reported its association with low serum lipid, few studies have investigated relationships between current suicidality and lipid profiles, comparing with other blood measures in MDD patients. The study population consisted of 555 subjects with MDD who were ≥ 18 years old, evaluated by the Mini International Neuropsychiatric Interview (MINI) with the suicidality module. At the evaluation visit, we measured serum lipid profiles including total cholesterol, triglycerides (TG), low-density lipoprotein (LDL), high-density lipoprotein (HDL), and very low-density lipoprotein (VLDL), and blood measures such as fasting glucose, total protein, albumin, blood urea nitrogen, creatinine, thyroid hormones, red and white blood cells, platelet count, hemoglobin, and hematocrit. Recent attempters who had attempted suicide within the past month showed significantly lower TG and higher HDL levels than lifetime and never attempters, using Tukey's post-hoc analysis. Recent attempters exhibited lower TG and higher HDL than those with recent suicide ideation and wish to self-harm and those without previous attempt. Linear regression analysis revealed that TG was negatively associated with current suicidality scores (β = -0.187, p = 0.039), whereas VLDL was positively associated with the recent suicide status (β = 0.198, p = 0.032) after controlling for age and sex. There were no significant differences between the groups in terms of other serum lipid profiles and blood measures. Low serum TG, high HDL and VLDL levels are associated with recent suicide attempt or recent suicide status in patients with MDD. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. The Preinterventional Cystatin-Creatinine-Ratio: A Prognostic Marker for Contrast Medium-Induced Acute Kidney Injury and Long-Term All-Cause Mortality.

    Science.gov (United States)

    Lüders, Florian; Meyborg, Matthias; Malyar, Nasser; Reinecke, Holger

    2015-01-01

    Contrast medium-induced acute kidney injury (CI-AKI) is an important iatrogenic complication following the injection of iodinated contrast media. The level of serum creatinine (SCr) is the currently accepted 'gold standard' to diagnose CI-AKI. Cystatin C (CyC) has been detected as a more sensitive marker for renal dysfunction. Both have their limitations. The role of the preinterventional CyC-SCr ratio for evaluating the risk for CI-AKI and long-term all-cause mortality was retrospectively analyzed in the prospective single-center 'Dialysis-versus-Diuresis trial'. CI-AKI was defined and staged according to the Acute Kidney Injury Network classification. Three hundred and seventy-three patients were included (average age 67.4 ± 10.2 years, 16.4% women, 29.2% with diabetes mellitus, mean baseline glomerular filtration rate 56.3 ± 20.2 ml/min/1.73 m(2) [as estimated by Chronic Kidney Disease Epidemiology Collaboration Serum Creatinine Cystatin C equation], 5.1% ejection fraction high significant association between preinterventional CyC-SCr ratio and long-term all-cause mortality (mean follow-up 649 days, hazards ratio 4.096, 95% CI 1.625-10.329, p = 0.003). The preinterventional CyC-SCr ratio is independently associated with CI-AKI and highly significant associated with long-term mortality after heart catheterization. © 2015 S. Karger AG, Basel.

  12. Analysis of 25(OHD serum concentrations of hospitalized elderly patients in the Shanghai area.

    Directory of Open Access Journals (Sweden)

    Xudong Mao

    Full Text Available OBJECTIVE: To find an association between basic characteristics, seasons as well as disease types and 25-Hydroxyvitamin D serum concentrations in Chinese patients. METHODS: We randomly selected 5470 Chinese patients with various diseases, who were hospitalized between May 2012 and August 2013 in Shanghai and analyzed their serum 25-Hydroxyvitamin D2 (25 (OHD2 and 25-Hydroxyvitamin D3 (25(OHD3 concentrations with liquid chromatography-tandem mass spectrometry (LC-MS/MS as well as their parathyroid hormone (PTH and serum creatinine blood levels. The resulting data were analyzed by linear regression and variance analyses or multivariate analysis with covariance. RESULTS: The 25(OHD serum concentrations were lowest in December. Among the subjects with a median age of 83.0 ± 16.0, the median 25(OHD2, 25(OHD3 and total 25(OHD serum concentrations were 1.00 ± 1.80 ng/ml, 12.20 ± 8.50 ng/ml and 14.80 ± 9.80 respectively, indicating a prevalent 25(OHD deficiency. According to our multivariate analysis of covariance, the factors affecting 25(OHD2 and 25(OHD3 serum concentrations included age, creatinine, PTH, season and type of disease, whereas gender correlated only with 25(OHD2 and 25(OHD2 and D3 values correlated negatively with each other. Our results further revealed that 25(OHD3 levels were low while 25(OHD2 levels were high among patients with lung diseases, dyskinesia and coronary heart diseases. In addition, participants with diabetes and cerebral infarction had higher 25(OHD3 serum concentrations compared with lung disease patients. CONCLUSION: Vitamin D intake particularly during winter and summer seasons is important especially for elderly lung disease, dyskinesia and coronary heart disease patients to improve their quality of life.

  13. Clinical significance of combined measurement of serum sex hormones in secondary amenorrhea

    International Nuclear Information System (INIS)

    Chen Boxun; Chen Yue; Gan Xilun

    2004-01-01

    Objective: To study the clinical significance of changes of levels of serum sex hormones in the diagnosis of the types of secondary amenorrhea. Methods: Serum sex hormones levels were measured with chemiluminescence in 100 patients with secondary amenorrhea and 42 controls. The serum hormones determined were: estradiol (E 2 )-, progesterone (PROG), follicle stimulating hormone (FSH)-, luteinizing hormone (LH), prolactin (PRL), testosterone (TSTO). Results: Patients with secondary amenorrhea had significantly higher levels of serum FSH, LH and PRL ( P 2 (P<0.05) than those in the controls. Serum levels of PROG and TSTO were about the same in the patients and controls. Conclusion: Determination of serum hormones levels with chemiluminescence is clinically useful for diagnosis of the types of secondary amenorrhea. (authors)

  14. Serum lipoprotein (a) concentration in patients with nephrotic syndrome and its clinical implication.

    Science.gov (United States)

    Yang, X; Wang, H; Zhu, Z; Deng, A

    1998-01-01

    Serum lipoprotein(a) [Lp(a)] concentration was determined in 42 patients with primary nephrotic syndrome (NS) and the relationships between Lp (a) and plasma lipids, apolipoproteins, serum creatinine (Scr), albumin, urinary proteins (Upro) were also analyzed. The results showed that: (1) serum Lp(a) concentrations in the patients with NS were higher than those in healthy controls; (2) the levels of serum Lp(a) were correlated positively with total cholesterol (TC), low density lipoprotein cholesterol (LDL-C), very low density lipoprotein cholesterol (VLDL-C), apolipoprotein B (Apo-B), Upros (Upro). It is concluded that the NS patients had the potential risk of suffering from coronary artery disease, glomerular sclerosis and thrombosis. The remission of NS may partially decrease the serum Lp(a) levels. Further studies are needed to explore the prevention and treatment of dislipedemia in patients with NS.

  15. The relation between serum testosterone levels and cardiovascular risk factors in patients with kidney transplantation

    Directory of Open Access Journals (Sweden)

    Hulya Colak

    2014-01-01

    Full Text Available The objective of the study is to evaluate the relationship between serum testos-terone levels and cardiovascular risk factors (CVRF in patients after kidney transplantation and with chronic kidney disease (CKD. Seventy-five male patients, aged between 18 and 68 years, who had kidney transplantation at least six months earlier, were enrolled into the study. Only renal transplant recipients and CKD patients with a creatinine level of 0.05. Serum testosterone levels were independent risk factors affecting IVC collapse index, systolic BP and LA. m-TORi and CNIs drugs might have no negative effect on serum testosterone levels, and improvement of the serum testosterone levels after transplantation might have a positive contribution on cardiac risk factors.

  16. Control of treatment of differentiated thyroid carcinoma by measurement of thyroglobulin in serum

    International Nuclear Information System (INIS)

    Hagemann, J.; Schneider, C.

    1978-01-01

    The presence of thyroglobulin in serum of patients with differentiated thyroid carcinoma was studied by a specific radioimmunoassay. Seventy-three patients with thyroid carcinomata were examined, 16 of whom had pulmonary or skeletal metastase, 11 local metastases, and the others no metastases. Patients with generalized metastases had very high serum thyroglobulin concentrations while those with local metastases had slightly elevated or normal concentrations. Those with remaining thyroid tissue had mainly normal thyroglobulin levels and patients with neither metastases nor remaining thyroid tissue had undetectable serum thyroglobulin. In seven patients with metastases it was possible to observe the development of serum thyroglobulin after 131 I treatment. In all cases the serum thyroglobulin concentration paralleled the development of the clinical status. Elevated serum thyroglobulin was also found in benign thyroid diseases such as hyperthyroidism and endemic goitre. Measurement of thyroglobulin in serum is therefore of little value in differentiating between benign and malignant thyroid diseases, but it is a good method for the follow-up control of patients with differentiated thyroid carcinomata. Because normal thyroglobulin levels do not exclude local metastases, additional examinations are necessary if normal thyroglobulin levels are found. When thyroglobulin is undetectable, metastases can be excluded and the measurement of thyroglobulin in serum can replace all other methods in the follow-up control. (author)

  17. Urine Albumin and Albumin/ Creatinine Ratio

    Science.gov (United States)

    ... it used? The urine albumin test or albumin/creatinine ratio (ACR) is used to screen people with chronic conditions, such as diabetes and high blood pressure ( hypertension ) that put them at an ...

  18. Serum bilirubin: a simple routine surrogate marker of the progression of chronic kidney disease.

    Science.gov (United States)

    Moolchandani, K; Priyadarssini, M; Rajappa, M; Parameswaran, S; Revathy, G

    2016-10-01

    Studies suggest that Chronic Kidney Disease (CKD) is a global burden health associated with significant comorbid conditions. Few biochemical parameters have gained significance in predicting the disease progression. The present work aimed to study the association of the simple biochemical parameter of serum bilirubin level with the estimated glomerular filtration rate (eGFR), and to assess their association with the co-morbid conditions in CKD. We recruited 188 patients with CKD who attended a Nephrology out-patient department. eGFR values were calculated based on the serum creatinine levels using CKD-EPI formula. Various biochemical parameters including glucose, creatinine, uric acid, total and direct bilirubin were assayed in all study subjects. Study subjects were categorized into subgroups based on their eGFR values and their diabetic status and the parameters were compared among the different subgroups. We observed a significantly decreased serum bilirubin levels (p bilirubin levels (r = 0.92). We also observed a significant positive correlation between the eGFR levels and the direct bilirubin levels (r = 0.76). On multivariate linear regression analysis, we found that total and direct bilirubin independently predict eGFR, after adjusting for potential confounders (p bilirubin may help in predicting the early progression of CKD and more so in diabetic CKD.

  19. The construction of a panel of serum amino acids for the identification of early chronic kidney disease patients.

    Science.gov (United States)

    Li, Rui; Dai, Jinna; Kang, Hui

    2018-03-01

    Serum creatinine, urea, and cystatin-c are standardly used for the evaluation of renal function in the clinic. However, some patients have chronic kidney disease but still retain kidney function; a conventional serum index in these patients can be completely normal. Serum amino acid levels can reflect subtle changes in metabolism and are closely related to renal function. Here, we investigated how amino acids change as renal impairment increases. Subjects were divided into three groups by renal function glomerular filtration rate: healthy controls, patients with chronic kidney disease with normal kidney function, and patients with chronic kidney disease with decreased kidney function group. We identified 11 amino acids of interest using LC-MS/MS on MRM (+) mode. Statistical analysis indicated that alanine (ALA), valine (VAL), and tyrosine (TYR) decrease with renal function impairment, whereas phenylalanine (PHE) and citrulline (CIT) increase. We tried to construct a diagnostic model utilizing a combination of amino acids capable of identifying early chronic kidney disease patients. The accuracy, specificity, and sensitivity of the combining predictors were 86.9%, 84.6%, and 90.9%, respectively, which is superior to the reported values for serum creatinine, urea, and cystatin-c. Our data suggest that serum amino acid levels may supply important information for the early detection of chronic kidney disease. We are the first to establish a diagnostic model utilizing serum levels of multiple amino acids for the diagnosis of patients with early-stage chronic kidney disease. © 2017 Wiley Periodicals, Inc.

  20. Use of urea and creatinine levels in vaginal fluid for the diagnosis of preterm premature rupture of membranes and delivery interval after membrane rupture.

    Science.gov (United States)

    Gezer, Cenk; Ekin, Atalay; Golbasi, Ceren; Kocahakimoglu, Ceysu; Bozkurt, Umit; Dogan, Askin; Solmaz, Ulaş; Golbasi, Hakan; Taner, Cuneyt Eftal

    2017-04-01

    To determine whether urea and creatinine measurements in vaginal fluid could be used to diagnose preterm premature rupture of membranes (PPROM) and predict delivery interval after PPROM. A prospective study conducted with 100 pregnant women with PPROM and 100 healthy pregnant women between 24 + 0 and 36 + 6 gestational weeks. All patients underwent sampling for urea and creatinine concentrations in vaginal fluid at the time of admission. Receiver operator curve analysis was used to determine the cutoff values for the presence of PPROM and delivery within 48 h after PPROM. In multivariate logistic regression analysis, vaginal fluid urea and creatinine levels were found to be significant predictors of PPROM (p 6.7 mg/dl for urea and >0.12 mg/dl for creatinine. The optimal cutoff values for the detection of delivery within 48 h were >19.4 mg/dl for urea and >0.23 mg/dl for creatinine. Measurement of urea and creatinine levels in vaginal fluid is a rapid and reliable test for diagnosing and also for predicting delivery interval after PPROM.

  1. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  2. Urinary excretion of creatine and creatinine in gamma irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Basu, S K; Srinivasan, M N; Chuttani, K; Bhatnagar, A; Ghose, A

    1985-06-01

    Dose response relationships of creatine, creatinine excretions and their ratio in 24 hr urine samples have been studied on each individual day upto 4 days after 1-7 Gy whole body gamma irradiation to rats. Creatine excretion reaches the peak on the 2nd day while creatinine excretion reaches the peak on the first day and a plateau is maintained up to the 4th day in each case. Good dose response correlationship is maintained for creatine or creatinine levels up to the 4th day and for creatine creatinine ratio up to the 3rd day. Seperate dose response curves are needed on each individual day for using these parameters for biological dosimetry purpose. Administration of the radioprotectors viz., combination of 5-hydroxytryptophan (HT) and 2-amino-ethylisothiuronium bromide hydrobromide (AET), HT alone and optimum radioprotecting dose of AET before 5 Gy whole body ..gamma..-irradiation have not been of help for reducing creatinineurea. (author).

  3. The association between creatinine versus cystatin C-based eGFR and cardiovascular risk in children with chronic kidney disease using a modified PDAY risk score.

    Science.gov (United States)

    Sharma, Sheena; Denburg, Michelle R; Furth, Susan L

    2017-08-01

    Children with chronic kidney disease (CKD) have a high prevalence of cardiovascular disease (CVD) risk factors which may contribute to the development of cardiovascular events in adulthood. Among adults with CKD, cystatin C-based estimates of glomerular filtration rate (eGFR) demonstrate a stronger predictive value for cardiovascular events than creatinine-based eGFR. The PDAY (Pathobiological Determinants of Atherosclerosis in Youth) risk score is a validated tool used to estimate the probability of advanced coronary atherosclerotic lesions in young adults. To assess the association between cystatin C-based versus creatinine-based eGFR (eGFR cystatin C and eGFR creatinine, respectively) and cardiovascular risk using a modified PDAY risk score as a proxy for CVD in children and young adults. We performed a cross-sectional study of 71 participants with CKD [median age 15.5 years; inter-quartile range (IQR) 13, 17], and 33 healthy controls (median age 15.1 years; IQR 13, 17). eGFR was calculated using age-appropriate creatinine- and cystatin C-based formulas. Median eGFR creatinine and eGFR cystatin C for CKD participants were 50 (IQR 30, 75) and 53 (32, 74) mL/min/1.73 m 2 , respectively. For the healthy controls, median eGFR creatinine and eGFR cystatin were 112 (IQR 85, 128) and 106 mL/min/1.73m 2 (95, 123) mL/min/1.73 m 2 , respectively. A modified PDAY risk score was calculated based on sex, age, serum lipoprotein concentrations, obesity, smoking status, hypertension, and hyperglycemia. Modified PDAY scores ranged from -2 to 20. The Spearman's correlations of eGFR creatinine and eGFR cystatin C with coronary artery PDAY scores were -0.23 (p = 0.02) and -0.28 (p = 0.004), respectively. Ordinal logistic regression also showed a similar association of higher eGFR creatinine and higher eGFR cystatin C with lower PDAY scores. When stratified by age creatinine and eGFR cystatin C with PDAY score were modest and similar in children [-0.29 (p = 0.008) vs. -0.32 (p = 0

  4. Some metabolic and anthropometric variables in obes children by measuring serum insulin, and leptin

    International Nuclear Information System (INIS)

    Nour Eldin, A.M.

    2004-01-01

    The present study aimed to assess serum leptin level in obese children to study its correlation with some metabolic variables as serum insulin and serum glucose. The study was conducted on 30 obese children of age from 9-14 years with body mass index (BMI) > 27.8 Kg/m 2 . All children were subjected to history taking, clinical examination, anthropometric measurements and laboratory investigations including fasting serum leptin, insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml) compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric measurements and laboratory investigations including fasting serum insulin and blood glucose. Serum leptin was significantly higher in obese children (102.3± 56.2 ng/ml)compared to non-obese ones (48.15±26.1 ng/ml). The relation between serum leptin and anthropometric variables was positively correlated with BMI r s = 0.68, (p s = 0.59.(p<0.01). It is concluded that serum leptin is increased in obesity and its concentration effects the size of the body. Moreover, the relation of leptin and insulin suggests a positive role of leptin in insulin resistance, which are common metabolic disorders associated with obesity

  5. The urine albumin-to-creatinine ratio is a reliable indicator for evaluating complications of chronic kidney disease and progression in IgA nephropathy in China

    Directory of Open Access Journals (Sweden)

    Lu Huan

    2016-05-01

    Full Text Available OBJECTIVE: This study investigated the correlation between the albumin-to-creatinine ratio in the urine and 24-hour urine proteinuria and whether the ratio can predict chronic kidney disease progression even more reliably than 24-hour proteinuria can, particularly in primary IgA nephropathy. METHODS: A total of 182 patients with primary IgA nephropathy were evaluated. Their mean urine albumin-to-creatinine ratio and 24-hour proteinuria were determined during hospitalization. Blood samples were also analyzed. Follow-up data were recorded for 44 patients. A cross-sectional study was then conducted to test the correlation between these parameters and their associations with chronic kidney disease complications. Subsequently, a canonical correlation analysis was employed to assess the correlation between baseline proteinuria and parameters of the Oxford classification. Finally, a prospective observational study was performed to evaluate the association between proteinuria and clinical outcomes. Our study is registered in the Chinese Clinical Trial Registry, and the registration number is ChiCTR-OCH-14005137. RESULTS: A strong correlation (r=0.81, p<0.001 was found between the ratio and 24-hour proteinuria except in chronic kidney disease stage 5. First-morning urine albumin-to-creatinine ratios of ≥125.15, 154.44 and 760.31 mg/g reliably predicted equivalent 24-hour proteinuria ‘thresholds’ of ≥0.15, 0.3 and 1.0 g/24 h, respectively. In continuous analyses, the albumin-to-creatinine ratio was significantly associated with anemia, acidosis, hypoalbuminemia, hyperphosphatemia, hyperkalemia, hypercholesterolemia and higher serum cystatin C. However, higher 24-hour proteinuria was only associated with hypoalbuminemia and hypercholesterolemia. Higher tubular atrophy and interstitial fibrosis scores were also associated with a greater albumin-to-creatinine ratio, as observed in the canonical correlation analysis. Finally, the albumin-to-creatinine

  6. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  7. Urinary oxalate to creatinine ratios in healthy Turkish schoolchildren.

    Science.gov (United States)

    Dursun, Ismail; Çelik, İlknur; Poyrazoglu, Hakan M; Köse, Kader; Tanrıkulu, Esen; Sahin, Habibe; Yılmaz, Kenan; Öztürk, Ahmet; Yel, Sibel; Gündüz, Zübeyde; Düşünsel, Ruhan

    2017-11-01

    we aimed to establish reference values for urinary oxalate to creatinine ratios in healthy children aged 6-15 years and to investigate the relationship between their nutritional habits and oxalate excretion. Random urine specimens from 953 healthy children aged 6-15 years were obtained and analyzed for oxalate and creatinine. Additionally, a 24-h dietary recall form was prepared and given to them. The ingredient composition of the diet was calculated. The children were divided into three groups according to age: Group I (69 years, n = 353), Group II (10-12 years, n = 335), and Group III (13-15 years, n = 265). The 95th percentile of the oxalate to creatinine ratio for subjects aged 6-9, 10-12, and 13-15 years were 0.048, 0.042, and 0.042 mg/mg, respectively. The oxalate to creatinine ratio was significantly higher in Group 1 than in Group 2 and Group 3. Urinary oxalate excretion was positively correlated with increased protein intake and negatively correlated with age. A significant positive correlation was determined between urinary oxalate excretion and the proline, serine, protein, and glycine content of diet. Dietary proline intake showed a positive correlation with the urine oxalate to creatinine ratio and was found to be an independent predictor for urinary oxalate. These data lend support to the idea that every country should have its own normal reference values to determine the underlying metabolic risk factor for kidney stone disease since regional variation in the dietary intake of proteins and other nutrients can affect normal urinary excretion of oxalate.

  8. Improvement in Creatinine Clearance after Open Heart Surgery in Infants as an Early Indicator of Surgical Success.

    Science.gov (United States)

    Dagan, Amit; Dagan, Ovadia

    2016-12-01

    Early surgical correction of congenital heart malformations in neonates and small infants may be complicated by acute kidney injury (AKI), which is associated with higher morbidity and mortality rates, especially in patients who require dialysis. Glomerular filtration rate (GFR) is considered the best measurement of renal function which, in neonates and infants, is highly dependent on heart function. To determine whether measurements of creatinine clearance after open heart surgery in neonates and young infants can serve as an early indicator of surgical success or AKI. We conducted a prospective observational study in 19 neonates and small infants (body weight creatinine clearance and albumin excretion was performed before and during surgery and four times during 48 hours after surgery. Mean creatinine clearance was lowest during surgery (25.2 ± 4. ml/min/1.73 m2) and increased significantly in the first 16 hours post-surgery (45.7 ± 6.3 ml/min/1.73 m2). A similar pattern was noted for urine albumin which was highest during surgery (203 ± 31 µg/min) and lowest (93 ± 20 µg/min) 48 hours post-surgery. AKI occurred in four patients, and two patients even required dialysis. All six showed a decline in creatinine clearance and an increase in urine albumin between 8 and 16 hours post-surgery. In neonates and small infants undergoing open heart surgery, a significant improvement in creatinine clearance in the first 16 hours postoperatively is indicative of a good surgical outcome. This finding has important implications for the early evaluation and treatment of patients in the intensive care unit on the first day post-surgery.

  9. Salivary creatinine and urea analysis in patients with chronic kidney disease: a case control study.

    Science.gov (United States)

    Lasisi, Taye Jemilat; Raji, Yemi Raheem; Salako, Babatunde Lawal

    2016-01-16

    Many metabolic changes develop in patients with chronic kidney disease which often necessitate frequent biochemical analysis of blood. Saliva analysis as an alternative to blood has many advantages. The aims of this study were to evaluate levels of salivary creatinine and urea in patients with chronic kidney disease in comparison to healthy individuals; to determine correlation between salivary creatinine/urea and blood creatinine/urea and to evaluate the diagnostic potential of saliva. A case control study, involving 50 patients with late stage chronic kidney disease and 49 healthy individuals as control. Blood and saliva samples were analyzed for urea and creatinine levels. Data are presented as median with interquartile range and compared using Independent Samples Mann Whitney U test. Correlation between plasma and salivary creatinine as well as urea was determined using Spearman's correlation test. Receiver operating characteristics (ROC) analysis was done to determine the diagnostic ability of salivary creatinine and urea and cut-off values were established. Median salivary creatinine levels were 2.60 mg/dl and 0.20 mg/dl while median salivary urea levels were 92.00 mg/dl and 20.50 mg/dl in patients with chronic kidney disease and controls respectively. Salivary levels of creatinine and urea were significantly elevated in chronic kidney disease patients (p creatinine as well as urea levels. Total areas under the curve for salivary creatinine and urea were 0.97 and 0.89 respectively. Cut-off values for salivary creatinine and urea were 0.55 mg/dl and 27.50 mg/dl respectively which gave sensitivity and specificity of 94 % and 85 % for creatinine; as well as 86 % and 93 % for urea. Findings of this study suggest that analysis of salivary creatinine and urea in patients with chronic kidney disease reflects their levels in blood. Hence, salivary creatinine and urea could be used as diagnostic biomarkers of chronic kidney disease.

  10. Serum Neutrophil Gelatinase-Associated Lipocalin in Infants and Children with Sepsis-Related Conditions with or without Acute Renal Dysfunction

    Directory of Open Access Journals (Sweden)

    Mohammed Farouk M. Afify

    2016-01-01

    Full Text Available Purpose To validate serum neutrophil gelatinase-associated lipocalin (NGAL as an early biomarker for acute kidney injury (AKI in sepsis-related conditions and its predictive and prognostic values. Patients and Methods This study included 65 patients, who were clinically evaluated for sepsis, severe sepsis, or septic shock, and 20 apparently healthy served as controls. Patients were divided into two groups: Group I (AKI-sepsis: 65 newly admitted patients diagnosed as sepsis, who were further divided into three subgroups according to the severity: systemic inflammatory response syndrome, severe sepsis, and septic shock, and Group II (control group: 20 apparently healthy subjects matched for age and sex, serum creatinine and serum NGAL concentrations were estimated initially within 24 hours of admission and after 72 hours of admission in all patients and control groups. Results Serum NGAL increased significantly with increasing severity of renal impairment. Receiver-operating characteristic analysis suggested that serum NGAL cutoff value of 40 ng/mL within the first 24 hours of admission is highly specific and sensitive for predicting AKI, with sensitivity of 90.9% and specificity of 75.8%. Conclusion We concluded that early measurement of serum NGAL level in sepsis can serve as a clinically useful marker for early prediction of AKI and for grading of its severity.

  11. Clinical Validation of Simultaneous Analysis of Tacrolimus, Cyclosporine A, and Creatinine in Dried Blood Spots in Kidney Transplant Patients.

    Science.gov (United States)

    Veenhof, Herman; Koster, Remco A; Alffenaar, Jan-Willem C; Berger, Stefan P; Bakker, Stephan J L; Touw, Daan J

    2017-07-01

    Monitoring of creatinine and immunosuppressive drug concentrations, such as tacrolimus (TaC) and cyclosporin A (CsA), is important in the outpatient follow-up of kidney transplant recipients. Monitoring by dried blood spot (DBS) provides patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. We performed a clinical validation in which we compared measurements from whole-blood samples obtained by venapuncture with measurements from DBS samples simultaneously obtained by fingerprick. After exclusion of 10 DBS for poor quality, and 2 for other reasons, 199, 104, and 58 samples from a total of 172 patients were available for validation of creatinine, TaC and CsA, respectively. Validation was performed by means of Passing & Bablok regression, and bias was assessed by Bland-Altman analysis. For creatinine, we found y = 0.73x - 1.55 (95% confidence interval [95% CI] slope, 0.71-0.76), giving the conversion formula: (creatinine plasma concentration in μmol/L) = (creatinine concentration in DBS in μmol/L)/0.73, with a nonclinically relevant bias of -2.1 μmol/L (95% CI, -3.7 to -0.5 μmol/L). For TaC, we found y = 1.00x - 0.23 (95% CI slope, 0.91-1.08), with a nonclinically relevant bias of -0.28 μg/L (95% CI, -0.45 to -0.12 μg/L). For CsA, we found y = 0.99x - 1.86 (95% CI slope, 0.91-1.08) and no significant bias. Therefore, for neither TaC nor CsA, a conversion formula is required. DBS sampling for the simultaneous analysis of immunosuppressants and creatinine can replace conventional venous sampling in daily routine.

  12. Transperitoneal transport of creatinine. A comparison of kinetic models

    DEFF Research Database (Denmark)

    Fugleberg, S; Graff, J; Joffe, P

    1994-01-01

    Six kinetic models of transperitoneal creatinine transport were formulated and validated on the basis of experimental results obtained from 23 non-diabetic patients undergoing peritoneal dialysis. The models were designed to elucidate the presence or absence of diffusive, non-lymphatic convective...... including all three forms of transport is superior to other models. We conclude that the best model of transperitoneal creatinine transport includes diffusion, non-lymphatic convective transport and lymphatic convective transport....

  13. Factors Associated with the Serum Myostatin Level in Patients Undergoing Peritoneal Dialysis: Potential Effects of Skeletal Muscle Mass and Vitamin D Receptor Activator Use.

    Science.gov (United States)

    Yamada, Shunsuke; Tsuruya, Kazuhiko; Yoshida, Hisako; Tokumoto, Masanori; Ueki, Kenji; Ooboshi, Hiroaki; Kitazono, Takanari

    2016-07-01

    Myostatin is a member of the transforming growth factor-β family, which regulates synthesis and degradation of skeletal muscle proteins and is associated with the development of sarcopenia. It is up-regulated in the skeletal muscle of chronic kidney disease patients and is considered to be involved in the development of uremic sarcopenia. However, serum myostatin levels have rarely been determined, and the relationship between serum myostatin levels with clinical and metabolic factors remains unknown. This cross-sectional study investigated the association between serum myostatin level and clinical factors in 69 outpatients undergoing peritoneal dialysis. Serum myostatin level was determined by commercially available enzyme-linked immunosorbent assay (ELISA). Univariable and multivariable analysis were conducted to determine factors associated with serum myostatin levels. The factors included age, sex, diabetes mellitus, dialysis history, body mass index, residual kidney function, peritoneal dialysate volume, serum biochemistries, and the use of vitamin D receptor activators (VDRAs). Mean serum myostatin level was 7.59 ± 3.37 ng/mL. There was no association between serum myostatin level and residual kidney function. Serum myostatin levels were significantly and positively associated with lean body mass measured by the creatinine kinetic method and negatively associated with the use of VDRAs after adjustment for potential confounding factors. Our study indicated that serum myostatin levels are associated with skeletal muscle mass and are lower in patients treated with VDRAs. Further studies are necessary to determine the significance of measuring serum myostatin level in patients undergoing peritoneal dialysis.

  14. [Concordance of glomerular filtration rate with creatinine clearance in 24-hour urine and Schwartz and Schwartz updated].

    Science.gov (United States)

    Salazar-Gutiérrez, María Luisa; Ochoa-Ponce, Cristina; Lona-Reyes, Juan Carlos; Gutiérrez-Íñiguez, Sara Ivonne

    Reference methods for the quantification of the glomerular filtration rate (GFR) are difficult to use in clinical practice; formulas for evaluating GFR based on serum creatinine (SCr) and/or creatinine clearance are used. The aim of this study was to quantify the correlation and concordance of GFR with creatinine clearance in 24-hour urine (GFR24) and Schwartz and Schwartz updated formulas. Cross-sectional study involving healthy pediatric patients and with chronic kidney disease (CKD) from 5 to 16.9 years. Linear correlation between GFR 24 and two formulas was evaluated with the Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC). We studied 134 patients, of which 59.7% were male. Mean age was 10.8 years. The average GFR24 was 140.34ml/min/1.73m 2 ; 34.3% (n=46) had GFR <90ml/min/1.73m 2 . Moderate linear correlation between GFR24 and Schwartz (r= 0.63) and Schwartz updated (r= 0.65) formulas was observed. There was good concordance between the GFR24 and Schwartz (ICC= 0.77) and updated Schwartz (ICC= 0.77) formulas. Schwartz classical formula in patients with GFR24 ≥ 90ml/min/1.73m 2 estimated higher values, while Schwartz updated underestimated values. There is moderate correlation and good concordance between the GFR24 and Schwartz and Schwartz updated formulas. The concordance was better in patients with obesity and lower in women, patients with hyperfiltration and normal weight. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  15. Mining of hospital laboratory information systems: a model study defining age- and gender-specific reference intervals and trajectories for plasma creatinine in a pediatric population.

    Science.gov (United States)

    Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas; Sørensen, Steen

    2015-09-01

    The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high-resolution gender- and age-groups. Normal probability plots were used to deduce parameters of the normal distributions from healthy creatinine values in the mixed hospital datasets. Furthermore, temporal trajectories were generated from repeated measurements to examine developmental patterns in periods of changing creatinine levels. Creatinine shows great age dependence from birth throughout childhood. We computed and replicated 95% reference intervals in narrow gender and age bins and showed them to be comparable to those determined in healthy population studies. We identified pronounced transitions in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods with pronounced heterogeneity and valid reference intervals. Furthermore, part of the heterogeneity in creatinine distribution is likely due to differences in biological and chronological age of children and should be considered when using age-specific reference intervals.

  16. Association of serum adiponectin concentration with aortic arterial stiffness in chronic kidney disease: from the KNOW-CKD study.

    Science.gov (United States)

    Kim, Chang Seong; Bae, Eun Hui; Ma, Seong Kwon; Park, Sue K; Lee, Ju Yeon; Chung, Wookyung; Lee, Kyubeck; Kim, Yeong Hoon; Oh, Kook-Hwan; Ahn, Curie; Kim, Soo Wan

    2017-08-01

    High serum adiponectin levels predict all-cause and cardiovascular mortality in chronic kidney disease (CKD). However, the relationship between serum adiponectin concentration and arterial stiffness in CKD is not well established. The aim of this study was to assess this relationship by measuring pulse wave velocity (PWV) in CKD patients. Serum adiponectin concentration was measured in 716 CKD patients in the prospective KoreaN cohort study for Outcome in patients With Chronic Kidney Disease. The study group consisted of 415 men and 301 women; mean age was 53.1 years, and baseline estimated glomerular filtration rate (eGFR) was 51 ± 29 ml/min per 1.73 m 2 . Heart to femoral PWV (hfPWV) and mean brachial to ankle PWV (baPWV) served as indicators of aortic artery stiffness and arterial stiffness, respectively. Increasing quartiles of serum adiponectin levels were associated with women, lower eGFRs and body mass indices, and higher urinary albumin-creatinine ratios. Serum adiponectin concentration also correlated with hfPWV and mean baPWV, even after adjusting for age and sex. It independently associated with hfPWV (B 0.028; 95 % confidence interval, 0.004-0.051; P = 0.020) but not mean baPWV in a multivariable linear regression analysis. In a multivariable logistic regression analysis, it correlated significantly with the highest quartile of hfPWVs but not mean baPWVs. The independent and significant correlation of serum adiponectin concentration with hfPWV in CKD patients implicates adiponectin in CKD-associated aortic stiffness.

  17. A Dual Electrochemical Sensor Based on a Test-strip Assay for the Quantitative Determination of Albumin and Creatinine.

    Science.gov (United States)

    Yasukawa, Tomoyuki; Kiba, Yuya; Mizutani, Fumio

    2015-01-01

    A dual-electrochemical sensor based on a test-strip assay with immunochemistry and enzyme reactions has been developed for the determination of albumin and creatinine. Each nitrocellulose membrane with an immobilization area of an anti-albumin antibody or three enzymes was prepared in the device with three working electrodes for measuring albumin, creatinine, and ascorbic acid, as well as an Ag/AgCl electrode used as a counter/pseudo-reference electrode. The reactions of three enzymes were initiated by flowing a solution containing creatinine to detect an oxidation current of hydrogen peroxide. A sandwich-type immunocomplex was formed by albumin and antibody labeled with glucose oxidase (GOx). Captured GOx catalyzed the reduction of Fe(CN)6(3-) to Fe(CN)6(4-), which was oxidized electrochemically to determine the captured albumin. The responses for creatinine and albumin increased with the concentrations in millimolar order and over the range 18.75 - 150 μg mL(-1), respectively. The present sensor would be a distinct demonstration for producing quantitative dual-assays for various biomolecules used for clinical diagnoses.

  18. High serum enalaprilat in chronic renal failure

    DEFF Research Database (Denmark)

    Elung-Jensen, T; Heisterberg, J; Kamper, A L

    2001-01-01

    renal failure. METHODS: Fifty nine out-patients with plasma creatinine >150 micromol/L and chronic antihypertensive treatment with enalapril were investigated, in a cross-sectional design. RESULTS: Median glomerular filtration rate (GFR) was 23(range 6-60) ml/minute/1.73 m2. The daily dose of enalapril......-68) ml/minute and correlated linearly with GFR (r=0.86, p=0.003). Intra-subject day-to-day variation in trough concentrations was 19.7%. CONCLUSION: Patients with chronic renal failure given small or moderately high doses of enalapril may thus have markedly elevated levels of serum enalaprilat. Whether...

  19. Glomerular filtration rate equations overestimate creatinine clearance in older individuals enrolled in the Baltimore Longitudinal Study on Aging: impact on renal drug dosing.

    Science.gov (United States)

    Dowling, Thomas C; Wang, En-Shih; Ferrucci, Luigi; Sorkin, John D

    2013-09-01

    To evaluate the performance of kidney function estimation equations and to determine the frequency of drug dose discordance in an older population. Cross-sectional analysis of data from community-dwelling volunteers randomly selected from the Baltimore Longitudinal Study of Aging from January 1, 2005, to December 31, 2010. A total of 269 men and women with a mean ± SD age of 81 ± 6 years, mean serum creatinine concentration (Scr ) of 1.1 ± 0.4 mg/dl, and mean 24-hour measured creatinine clearance (mClcr ) of 53 ± 13 ml/minute. Kidney function was estimated by using the following equations: Cockcroft-Gault (CG), Modification of Diet in Renal Disease (MDRD), and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI). The performance of each equation was assessed by measuring bias and precision relative to mClcr . Dose calculation errors (discordance) were determined for 10 drugs requiring renal dosage adjustments to avoid toxicity when compared with the dosages approved by the Food and Drug Administration. The CG equation was the least biased estimate of mClcr . The MDRD and CKD-EPI equations were significantly positively biased compared with CG (mean ± SD 34 ± 20% and 22 ± 15%, respectively, prenal impairment. Thus equations estimating glomerular filtration rate should not be substituted in place of the CG equation in older adults for the purpose of renal dosage adjustments. In addition, the common practice of rounding or replacing low Scr values with an arbitrary value of 1.0 mg/dl for use in the CG equation should be avoided. Additional studies that evaluate alternative eGFR equations in the older populations that incorporate pharmacokinetic and pharmacodynamic outcomes measures are needed. © 2013 Pharmacotherapy Publications, Inc.

  20. Effect of Melatonin on Carbon Tetrachloride- Induced Kidney Injury ...

    African Journals Online (AJOL)

    Dr Olaleye

    creatinine, blood urea nitrogen (BUN), nitrite and albumin concentrations were measured for the evaluation of renal ... was observed in CCl4-treated rats as assessed by increased serum creatinine, BUN levels and decreased creatinine and .... before the commencement of our experiments. At the end of experimental period ...

  1. Bivariate analysis of basal serum anti-Mullerian hormone measurements and human blastocyst development after IVF

    LENUS (Irish Health Repository)

    Sills, E Scott

    2011-12-02

    Abstract Background To report on relationships among baseline serum anti-Müllerian hormone (AMH) measurements, blastocyst development and other selected embryology parameters observed in non-donor oocyte IVF cycles. Methods Pre-treatment AMH was measured in patients undergoing IVF (n = 79) and retrospectively correlated to in vitro embryo development noted during culture. Results Mean (+\\/- SD) age for study patients in this study group was 36.3 ± 4.0 (range = 28-45) yrs, and mean (+\\/- SD) terminal serum estradiol during IVF was 5929 +\\/- 4056 pmol\\/l. A moderate positive correlation (0.49; 95% CI 0.31 to 0.65) was noted between basal serum AMH and number of MII oocytes retrieved. Similarly, a moderate positive correlation (0.44) was observed between serum AMH and number of early cleavage-stage embryos (95% CI 0.24 to 0.61), suggesting a relationship between serum AMH and embryo development in IVF. Of note, serum AMH levels at baseline were significantly different for patients who did and did not undergo blastocyst transfer (15.6 vs. 10.9 pmol\\/l; p = 0.029). Conclusions While serum AMH has found increasing application as a predictor of ovarian reserve for patients prior to IVF, its roles to estimate in vitro embryo morphology and potential to advance to blastocyst stage have not been extensively investigated. These data suggest that baseline serum AMH determinations can help forecast blastocyst developmental during IVF. Serum AMH measured before treatment may assist patients, clinicians and embryologists as scheduling of embryo transfer is outlined. Additional studies are needed to confirm these correlations and to better define the role of baseline serum AMH level in the prediction of blastocyst formation.

  2. Clinical review: improving the measurement of serum thyroglobulin with mass spectrometry.

    Science.gov (United States)

    Hoofnagle, Andrew N; Roth, Mara Y

    2013-04-01

    Serum thyroglobulin (Tg) measurements are central to the management of patients treated for differentiated thyroid carcinoma. For decades, Tg measurements have relied on methods that are subject to interference by commonly found substances in human serum and plasma, such as Tg autoantibodies. As a result, many patients need additional imaging studies to rule out cancer persistence or recurrence that could be avoided with more sensitive and specific testing methods. The aims of this review are to: 1) briefly review the interferences common to Tg immunoassays; 2) introduce readers to liquid chromatography-tandem mass spectrometry as a method for quantifying proteins in human serum/plasma; and 3) discuss the potential benefits and limitations of the method in the quantification of serum Tg. Mass spectrometric methods have traditionally lacked the sensitivity, robustness, and throughput to be useful clinical assays. These methods failed to meet the necessary clinical benchmarks due to the nature of the mass spectrometry workflow and instrumentation. Over the past few years, there have been major advances in reagents, automation, and instrumentation for the quantification of proteins using mass spectrometry. More recently, methods using mass spectrometry to detect and quantify Tg have been developed and are of sufficient quality to be used in the management of patients. Novel serum Tg assays that use mass spectrometry may avoid the issue of autoantibody interference and other problems with currently available immunoassays for Tg. Prospective studies are needed to fully understand the potential benefits of novel Tg assays to patients and care providers.

  3. Reliable clinical serum analysis with reusable electrochemical sensor: Toward point-of-care measurement of the antipsychotic medication clozapine.

    Science.gov (United States)

    Kang, Mijeong; Kim, Eunkyoung; Winkler, Thomas E; Banis, George; Liu, Yi; Kitchen, Christopher A; Kelly, Deanna L; Ghodssi, Reza; Payne, Gregory F

    2017-09-15

    Clozapine is one of the most promising medications for managing schizophrenia but it is under-utilized because of the challenges of maintaining serum levels in a safe therapeutic range (1-3μM). Timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine, which is however challenging due to the complexity of serum samples. We demonstrate a robust and reusable electrochemical sensor with graphene-chitosan composite for rapidly measuring serum levels of clozapine. Our electrochemical measurements in clinical serum from clozapine-treated and clozapine-untreated schizophrenia groups are well correlated to centralized laboratory analysis for the readily detected uric acid and for the clozapine which is present at 100-fold lower concentration. The benefits of our electrochemical measurement approach for serum clozapine monitoring are: (i) rapid measurement (≈20min) without serum pretreatment; (ii) appropriate selectivity and sensitivity (limit of detection 0.7μM); (iii) reusability of an electrode over several weeks; and (iv) rapid reliability testing to detect common error-causing problems. This simple and rapid electrochemical approach for serum clozapine measurements should provide clinicians with the timely point-of-care information required to adjust dosages and personalize the management of schizophrenia. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples

  5. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low

  6. Serum aluminium levels of workers in the bauxite mines.

    Science.gov (United States)

    de Kom, J F; Dissels, H M; van der Voet, G B; de Wolff, F A

    1997-01-01

    Aluminium is produced from the mineral bauxite. Occupational exposure is reported during the industrial processing of aluminium and is associated with pulmonary and neurotoxicity. However, data on exposure and toxicity of workers in the open bauxite mining industry do not exist. Therefore, a study was performed to explore aluminium exposure in employees involved in this bauxite mining process in a Surinam mine. A group of workers occupationally exposed to aluminium in an open bauxite mine were compared with a group of nonexposed wood processors. Serum aluminium was analyzed using atomic absorption spectrometry Data from the clinical chemistry of the blood and a questionnaire were used to explore determinants for aluminium exposure. No significant difference between serum aluminium in the exposed (4.4 +/- 2.0 micrograms/L, n = 27) and control group (5.1 +/- 1.5 micrograms/L, n = 27) was detected. For the serum concentration of the clinical chemical variables (calcium, citrate, and creatinine), a statistically significant difference was computed (p < or = 0.02) between the exposed and control group. All levels were slightly higher in the exposed group; no statistically significant correlations with serum aluminium were found. In this study, serum aluminium values were in the normal range, no significant difference between the groups could be detected despite long-term occupational exposure.

  7. A quest for normal values of serum aminotransferase and its association with age and body mass index

    International Nuclear Information System (INIS)

    Farooq, M.A.; Farooq, Y.; Khan, M.A.

    2016-01-01

    Objective: To determine the reference range for serum alanine aminotransferase (ALT) levels for young healthy individuals in our population and to find out effects of age and body mass index on alanine aminotransferase. Study Design: Descriptive cross sectional study. Place and Duration of Study: Military Hospital Rawalpindi; from Dec 2009 to April 2010. Material and Methods: Five hundred and fifty three young healthy adults were included in the study. Detailed history was taken. Parameters like Age, height and weight were measured. Relevant investigations were carried out for each subject which included blood complete picture, Chest X-Ray, ECG, Urine routine examination, liver function tests, serum urea, serum creatinine, serum uric acid, plasma glucose (F), Anti HCV antibodies, HBsAg, HIV antibodies and VDRL. Data was analyzed using SPSS version 22. Results: Age of subjects ranged from 19 to 50 years (29 +- 6) years, BMI 15.59 to 29.8, (21.58 +- 2). Serum alanine aminotransferase ranged from 17 to 81 IU/l, (29.9 +- 8) IU/l. Serum alanine aminotransferase for subjects with body mass index more than 25 Kg/m2 was 29.6 +- 7 IU/L. There is no significant difference in value of mean ALT overall and in those with BMI of more than 25 (p=0.149) Conclusion: Mean serum alanine aminotransferase value in young healthy adults included in this study was 29.9 +- 8 IU/L which is lower than normal reference provided at present which is 40 IU/l. Statistical analysis revealed that serum ALT is not significantly influenced by age and BMI. (author)

  8. Microcantilever based disposable viscosity sensor for serum and blood plasma measurements.

    Science.gov (United States)

    Cakmak, Onur; Elbuken, Caglar; Ermek, Erhan; Mostafazadeh, Aref; Baris, Ibrahim; Erdem Alaca, B; Kavakli, Ibrahim Halil; Urey, Hakan

    2013-10-01

    This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23°C and 37°C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 μl and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges. Copyright © 2013. Published by Elsevier Inc.

  9. Detection of creatinine enriched on a surface imprinted polystyrene film using FT-ATR-IR.

    Science.gov (United States)

    Sreenivasan, K

    2006-01-01

    The surface of polystyrene (PS) was chemically modified by coating a thin layer of polyaniline (PANI) by oxidizing aniline using ammonium persulfate. Affinity sites for creatinine, a clinically relevant molecule, were created in the coated layer by adding creatinine as print molecules during the oxidation. The imprinted layer adsorbed creatinine was compared to non-imprinted surface reflecting the creation of creatinine-specific sites on the surface. The equilibrium was attained rapidly, indicating that a material of this kind is suitable for sensing applications. The adsorbed creatinine on the surface was detected using the technique of Fourier transform attenuated total internal reflection infra red spectroscopy (FT-ATR-IR). The results show that molecularly imprinted surface can enrich molecules of interest and the enriched molecules can be detected using FT-IR.

  10. Measurement of rat serum FSH by radioreceptor assay and comparison with radioimmunoassay

    International Nuclear Information System (INIS)

    Minegishi, Takashi; Igarashi, Masao; Wakabayashi, Katsumi

    1980-01-01

    Follicle stimulating hormone (FSH) in rat serum is successfully measured by a radioreceptor assay system employing PMS-treated immature rat ovary. The non-specific inhibitory effect of serum was partially overcome by the addition of merthiolate to every component, while the residual effect was compensated for by using FSH-free serum which was prepared by passing the pooled female diestrous rat sera through an immunoadsorbent column packed with anti-ovine FSH-coupled Sepharose 4B. The assay system consisted of 100 μl of Tris-MgCl 2 -BSA or standard, 100 μl of FSH-free serum or sample, 100 μl of the receptor preparation and 100 μl of 125 I-FSH. The incubation was carried out for 4 hr at 37 0 C and 500 μl of cold Tris-MgCl 2 -BSA was used for the termination. Serum FSH could be measured within a range of 0.125 - 16 ng NIAMDD rat FSH I-3/tube. The mean within-assay coefficient of variation was 10.5%. The mean between-assay coefficient of variation was 11.0%. The assay values obtained by RRA showed a good correlation to those by RIA under the same physiological states of the animals. The ratio of the assay values, RRA/RIA, was found to change according to the sex and the physiological states, e.g. around 1.3 in normal males and 1.7 in orchiectomized animals and 2.21 in female rats. Serum FSH levels in female rats obtained by RRA and RIA changed almost in parallel until 20:00 (hr) of proestrous day, but after the first surge of serum FSH they were not parallel. These facts seem to indicate possible changes in the affinity of FSH with its receptor according to the state of animals and lead to the problem of the heterogeneity of FSH. (author)

  11. Initial dose of vancomycin based on body weight and creatinine clearance to minimize inadequate trough levels in Japanese adults.

    Science.gov (United States)

    Maki, N; Ohkuchi, A; Tashiro, Y; Kim, M R; Le, M; Sakamoto, T; Matsubara, S; Hakamata, Y

    2012-10-01

    Our aims were to elucidate the factors that affected vancomycin (VCM) serum trough levels and to find the optimal initial dose based on creatinine clearance (CrCl) and body weight (BW) to minimize inadequate trough levels in a retrospective observational study among Japanese adults. One hundred and six inpatients, in whom VCM trough levels were measured after completing the third dosing, were consecutively recruited into our study in a tertiary hospital. We considered the frequency of initial VCM total daily dose, CrCl, and BW were independent risk factors of VCM trough levels. In patients with CrCl ≥30 and level of ≥20 mcg/mL, regardless of BW. In patients with CrCl ≥50 mL/min, 2 g/day yielded low frequencies of a trough level of initial total daily dose may be 1 g/day in patients with CrCl ≥30 and <50 mL/min regardless of BW and 2 g/day in patients weighing <55 kg with CrCl ≥50 mL/min among Japanese adults.

  12. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... of serum HIV RNA (p normal allele (p

  13. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  14. An improved amperometric creatinine biosensor based on nanoparticles of creatininase, creatinase and sarcosine oxidase.

    Science.gov (United States)

    Kumar, Parveen; Jaiwal, Ranjana; Pundir, C S

    2017-11-15

    An improved amperometric biosensor for detection of creatinine was developed based on immobilization of nanoparticles (NPs) of creatininase (CA), creatinase (CI), and sarcosine oxidase (SOx) onto glassy carbon (GC) electrode. Transmission electron microscopy (TEM) and fourier transform infrared spectroscopy (FTIR) were employed for characterization of enzyme nanoparticles (ENPs). The GC electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectra (EIS) at different stages of its amendment. The biosensor showed optimum response within 2s at pH 6.0 in 0.1 M sodium phosphate buffer and 25 °C, when operated at 1.0 V against Ag/AgCl. Biosensor exhibited wider linear range from 0.01 μM to 12 μM with a limit of detection (LOD) of 0.01 μM. The analytical recoveries of added creatinine in sera were 97.97 ± 0.1% for 0.1 mM and 98.76 ± 0.2% for 0.15 mM, within and between batch coefficients of variation (CV) were 2.06% and 3.09% respectively. A good correlation (R 2  = 0.99) was observed between sera creatinine values obtained by standard enzymic colorimetric method and the present biosensor. This biosensor measured creatinine level in sera of apparently healthy subjects and persons suffering from renal and muscular dysfunction. The ENPs electrode lost 10% of its initial activity within 240 days of its regular uses, when stored at 4 °C. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A facile low-cost enzymatic paper-based assay for the determination of urine creatinine.

    Science.gov (United States)

    Talalak, Kwanrutai; Noiphung, Julaluk; Songjaroen, Temsiri; Chailapakul, Orawon; Laiwattanapaisal, Wanida

    2015-11-01

    Creatinine is one of many markers used to investigate kidney function. This paper describes a low-cost enzymatic paper-based analytical device (enz-PAD) for determining urine creatinine. The disposable dead volumes of creatinine enzyme reagents from an automatic analyser cassette were utilised. Whatman No. 3 paper was cut into long rectangular shapes (4×40 mm(2)) on which the enzyme reagents, R1 and R2, were adsorbed in two consecutive regions. The assay was performed by immersing test strips into urine samples contained in microwells to allow creatinine in the sample to react with immobilised active ingredients and, then, traverse via capillary action to the detection area where chromogen products accumulated. The method is based on hydrogen peroxide (H2O2) formation via creatinine conversion using creatininase, creatinase, and sarcosine oxidase. The liberated H2O2 reacts with 4-aminophenazone and 2,4,6-triiodo-3-hydroxybenzoic acid to form quinoneimine with a pink-red colour at the detection zone. The linear range of the creatinine assay was 2.5-25 mg dL(-1) (r(2)=0.983), and the detection limit was 2.0 mg dL(-1). The colorimetric enz-PAD for the creatinine assay was highly correlated with a conventional alkaline picrate method when real urine samples were evaluated (r(2)=0.977; n=40). This simple and nearly zero-cost paper-based device provides a novel alternative method for screening urinary creatinine and will be highly beneficial for developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Radioisotopic measurement of glomerular filtration rate in severe chronic renal failure

    International Nuclear Information System (INIS)

    LaFrance, N.D.; Drew, H.H.; Walser, M.

    1988-01-01

    In order to determine the best method for routine measurement of glomerular filtration rate (GFR) in severe renal failure, we compared simultaneously the urinary clearances of [/sup 99m/Tc] diethylenetriaminepentaacetic acid (DTPA) (UD), [ 125 I]iothalamate (UI), 24-hr creatinine clearance (UC) and plasma clearance of [/sup 99m/Tc]DTPA (PD), based on three plasma samples. In 60 studies in 22 patients with serum creatinine values of 2 to 8 mg/dl, UD and UI were almost identical: UD = 0.358 +/- 0.976 UI +/- 0.87 ml/min, r = 0.990. However, PD overestimated UD by a large and variable extent: PD = 11.3 +/- 0.843 UD +/- 5.5 ml/min, r = 0.694, and was inconsistent in sequential measurements in individual patients. UC also overestimated urinary isotope clearance: UC = 4.2 + 0.95 UI +/- 3.9 ml/min, r = 0.865. Sequential measurements of GFR in five patients with severe but stable renal failure (mean GFR 5.9 ml/min) showed an average standard deviation of only 0.83 ml/min. Thus both UD and UI appear to be reliable and precise measures of GFR in severe renal failure

  17. Bilirubin concentration is positively associated with haemoglobin concentration and inversely associated with albumin to creatinine ratio among Indigenous Australians: eGFR Study.

    Science.gov (United States)

    Hughes, J T; Barzi, F; Hoy, W E; Jones, G R D; Rathnayake, G; Majoni, S W; Thomas, M A B; Sinha, A; Cass, A; MacIsaac, R J; O'Dea, K; Maple-Brown, L J

    2017-12-01

    Low serum bilirubin concentrations are reported to be strongly associated with cardio-metabolic disease, but this relationship has not been reported among Indigenous Australian people who are known to be at high risk for diabetes and chronic kidney disease (CKD). serum bilirubin will be negatively associated with markers of chronic disease, including CKD and anaemia among Indigenous Australians. A cross-sectional analysis of 594 adult Aboriginal and Torres Strait Islander (TSI) people in good health or with diabetes and markers of CKD. Measures included urine albumin: creatinine ratio (ACR), estimated glomerular filtration rate (eGFR), haemoglobin (Hb) and glycated haemoglobin (HbA1c). Diabetes was defined by medical history, medications or HbA1c≥6.5% or ≥48mmol/mol. Anaemia was defined as Hbbilirubin was performed. Participants mean (SD) age was 45.1 (14.5) years, and included 62.5% females, 71.7% Aboriginal, 41.1% with diabetes, 16.7% with anaemia, 41% with ACR>3mg/mmol and 18.2% with eGFRbilirubin concentration was lower in females than males (6 v 8μmol/L, pbilirubin; Hb and cholesterol (both positively related) and ACR, triglycerides, Aboriginal ethnicity and female gender (all inversely related). Serum bilirubin concentrations were positively associated with Hb and total cholesterol, and inversely associated with ACR. Further research to determine reasons explaining lower bilirubin concentrations among Aboriginal compared with TSI participants are needed. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Relationship of serum magnesium levels and other metabolic indices in renal transplant recipients receiving cyclosporine

    Directory of Open Access Journals (Sweden)

    Ahmadi F

    2008-10-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Cyclosporine is one of the main immunosuppressors used for renal transplant recipients, and is given to prevent transplant rejection. Although the drug increases the survival of patients and grafted organs, it has some side effects independent of its effect on the immune system that are usually ignored. In this study, we evaluate the effect of cyclosporine on serum Mg levels and metabolic side effects in renal graft patients."n"n Methods: In this study, we followed 157 renal transplant recipients (62 females and 95 males who were being treated with cyclosporine at a private clinic to prevent transplant rejection. The patients were first physically examined and then blood samples were obtained in order to measure levels of cyclosporine, Mg, creatinine, fasting blood sugar, lipids, calcium, phosphorus, and uric acid levels. We then analyzed the data for correlations between serum Mg levels, cyclosporine and other metabolic complications."n"n Results: The mean levels of Mg and cyclosporine were 196±0.31mg/dl and 371±192 μg/dl, respectively. Hypomagnesemia was detected in 16 patients (10.2%.There was a significant negative correlation (p<0.05 between levels of Mg and cyclosporine levels (r=-0.53, serum

  19. Estimating renal function in children: a new GFR-model based on serum cystatin C and body cell mass.

    Science.gov (United States)

    Andersen, Trine Borup

    2012-07-01

    present model also had the highest R E2 and the narrowest 95% limits of agreement. If replacing BCM with weight (Weight-model) the results were almost as convincing. The total day-to-day variation of the GFR-estimate (7.7%) was low. The two new models are, however, still not sufficiently accurate to replace exogenous markers when GFR must be determined with high accuracy. Study II aimed at determining biological variation and analytical precision of serum CysC and creatinine. The precision of CysC (1.7%), and creatinine (2.5%) was very good and the day-to-day variation of CysC and creatinine (within-subject variation between two days) also proved very low (6.4% for both analytes). Because of a relatively low ratio between within-subject variation and between-subject variation neither CysC nor creatinine seems qualified to discriminate between normal and reduced renal function, which was also confirmed in study IV. However, the relatively low total day-to-day variation of 6.6% (CysC) and 6.9% (creatinine) indicate that both are suitable for detecting changes in renal function over time. Study III aimed at determining biological variation and analytical precision of BCM and all other parameters given by measurement by bioimpedance spectroscopy (BIS). Depending on parameter the precision was 0.3-0.8% in children ≥ 6 years and 0.5-2.4% in children thesis we are able to provide the clinician with both a reasonably accurate estimate of renal function and a probability of reduced renal function. Furthermore, the positive results from study II and III on precision and biological variation indicate that CysC, creatinine and BCM are very stable variables, which is an indirect validation of the BCM-model´s precision and validity. This is also reflected in the relatively low total day-to-day variation of the GFR-estimate.

  20. Influence of hypernatremia and polyuria of brain-dead donors before organ procurement on kidney allograft function.

    Science.gov (United States)

    Kazemeyni, Seyed Mohammad; Esfahani, Fatemah

    2008-01-01

    Polyuria and hypernatremia are common problems during the pretransplant care of brain-dead donors. They have not only important role in hemodynamic stability, but also may influence organ transplantation outcomes. The influence of donor hypernatremia in liver transplantation was reported. This study aimed to determine these effects on kidney allograft. We retrospectively studied on 57 transplanted kidney allografts from cadaveric donors. The effects of the urine output volume and serum level of sodium of the donors were on the recipients' serum creatinine levels 1 week after transplantation and at the last follow-up visit were assessed. Of the donors, 58% had polyuria and 45% had hypernatremia. The median pretransplant urine output of the donors was 130 mL/h (range, 35 mL/h to 450 mL/h), and their mean serum sodium level was 152.0 +/- 13.0 mEq/L. Serum creatinine concentrations in the recipients at the 1st posttransplant week correlated significantly with the recipients' age (r = 0.355, P = .02) and the donors' urine output volume (r = 0.329, P = .04). The serum creatinine measured in the last follow-up visit significantly correlated only with the donors' serum sodium levels (r = 0.316, P = .02) and the donors' age (r = 0.306, P = .02). Multivariate regression analysis showed that the donors' serum levels of sodium and potassium were the predictors of the last measured serum creatinine level. Polyuria and hypernatremia in brain-dead donors are frequent. Elevated serum level of sodium and polyuria in the donor can have adverse effects on kidney allograft function.