WorldWideScience

Sample records for serologic test results

  1. Retrospective Review of Treponema pallidum PCR and Serology Results: Are Both Tests Necessary?

    Science.gov (United States)

    Brischetto, Anna; Gassiep, Ian; Whiley, David; Norton, Robert

    2018-05-01

    There has been a resurgence of syphilis diagnoses in Australia. We investigated whether our Treponema pallidum PCR test provides any additional diagnostic information over syphilis serology (chemiluminescence immunoassay [CMIA], Treponema pallidum particle agglutination [TPPA] assay, and the rapid plasma reagin [RPR] flocculation test). A retrospective audit of all T. pallidum PCR requests that came through our laboratory from January 2010 to June 2017 was conducted; data collected included age, gender, site of swab, and results from T. pallidum PCR, syphilis serology, and herpes simplex virus 1 (HSV-1) and HSV-2 PCRs. A total of 441 T. pallidum PCR tests were performed; on average, 3 T. pallidum PCRs per month were requested in 2011, and this rate increased to 17.2 requests per month in 2017. A total of 323 patients had both T. pallidum PCR and syphilis serology performed, with 67% of swabs taken from the genitals. T. pallidum PCR gave positive results for 61/323 (19%) patients; of these 61 patients, 59 (97%) also had positive syphilis serology results ( T. pallidum PCR sensitivity, 68%; specificity, 99%; positive predictive value, 97%; negative predictive value, 89%). Syphilis serology was positive for 91/323 patients (28%); of these 91 patients, 61 (66%) were also T. pallidum PCR positive (syphilis serology sensitivity, 97%; specificity, 88%; positive predictive value, 60%; negative predictive value, 99%). The Cohen's kappa value was 0.74, indicating substantial agreement between the two tests. Our results show that most patients with positive T. pallidum PCR results also had positive syphilis serology. Therefore, T. pallidum PCR adds little clinical value over serology for the diagnosis of syphilis in certain clinical settings. Copyright © 2018 American Society for Microbiology.

  2. Serological tests in venereal syphilis

    OpenAIRE

    Notowicz, Alfred

    1981-01-01

    textabstractApart from identification of the causative microorganism, serological blood testing is still the principal aid in the diagnosis of venereal syphilis. In latent syphilis it is in fact the only diagnostic aid. In the diagnosis of late symptomatic syphilis, additional organ-specific diagnostic procedures are indispensable. Interpretation of the results of serological syphilis tests often poses problems in actual practice. Apart from possibly inadequate knowledge of the natural histor...

  3. Positive results of serological tests for syphilis in pregnancy – diagnostic and therapeutic problems, report of two cases

    OpenAIRE

    Marta Koper; Agnieszka B. Serwin; Anna Baran; Iwona Flisiak

    2015-01-01

    Introduction. Undiagnosed and untreated syphilis in pregnancy may result in subsequent complications: early fetal loss, stillbirth, low birth weight of infants and newborns with congenital syphilis. Objective. To analyze diagnostic and therapeutic dilemmas of positive results of serological tests for syphilis (STS) in pregnancy. Case reports. We present two cases of pregnant women, hospitalized in our department due to positive results of serological tests for syphilis, pe...

  4. Association of serologic and hematologic test results in dengue infant patients in RSUP. Dr. Hasan Sadikin Bandung

    Science.gov (United States)

    Alam, A.; Handayani, I.; Indrati, A. R.

    2018-03-01

    The incidence of Dengue virus infection is increasing every year,and the progression of the disease is faster towards severe manifestations in infants than in children and adults.The clinical appearance is still challenging to make for the diagnosis of dengue fever, so routine blood examination becomes one of thefurther enforcement efforts. The gold standard isconfirmatory tests for dengue, but this examination would be difficult in remote areas and also cost more. Research on serological testing and its association with routine blood testing in infant dengue-infected patients is still less publicized. The purpose of this study was to describe theconnection between serological and routine blood test results of infant dengue infection patients in RSUP Dr. Hasan Sadikin. Observational design in dengue 56 infants with 2-12 months age range examined serologic test and routine blood examination. The results showed that serological testing tended to be on routine blood tests. It can be from differences in routine blood tests such as hemoglobin, hematocrit, and platelets. Also, there was also no difference in routine blood profile between reactive and non-reactive IgM groups. It suggests that routine blood examination results are still lacking for the diagnosis of dengue.

  5. Evaluating enzootic bovine leukemia virus infection by means of molecular probe compared with the results of serological tests

    International Nuclear Information System (INIS)

    Reichert, M.; Grundbock, J.; Rulka, J.; Kozaczynska, B.; Stec, J.

    1994-01-01

    The present studies were aimed at determining the relation between the finding obtained by means of serological tests and the specific molecular probe. Serological tests were performed according to the methods recommended by the Polish Ministry of Agriculture; ELISA was run with ''Bioveta'' and ''Rhone Merieux'' kits and the AGID test was performed with EBL antigen made in our laboratory. The molecular probe was prepared from the previously cloned provirus DNA of EBL virus. The EBL provirus was detected in 28 samples taken from 44 randomly selected cows in three herds on which a leukemia eradication programme was in process. Three sera out of 28 positive reacting animals were negative in AGID test and only one serum in ELISA. The results indicate that the use of a specific molecular probe has some advantages in the diagnosis of latent virus infections. Besides, it can be applied in the studies on the pathogenesis of enzootic bovine leukemia. (author). 13 refs, 1 fig., 1 tab

  6. Positive results of serological tests for syphilis in pregnancy – diagnostic and therapeutic problems, report of two cases

    Directory of Open Access Journals (Sweden)

    Marta Koper

    2015-06-01

    Full Text Available Introduction. Undiagnosed and untreated syphilis in pregnancy may result in subsequent complications: early fetal loss, stillbirth, low birth weight of infants and newborns with congenital syphilis. Objective. To analyze diagnostic and therapeutic dilemmas of positive results of serological tests for syphilis (STS in pregnancy. Case reports. We present two cases of pregnant women, hospitalized in our department due to positive results of serological tests for syphilis, performed during the antenatal visit. On the basis of patients' history, physical examination and STS results, early latent syphilis was diagnosed in the first patient; biological false positive reactions were considered in the second one. Both patients received procaine penicillin treatment. Conclusions. Screening for syphilis in pregnancy as a part of antenatal care and appropriate treatment with penicillin are the most effective interventions to prevent complications of syphilis in pregnancy. It is also important to adapt modern European Guidelines for management of syphilis to Polish conditions.

  7. Serological tests in venereal syphilis

    NARCIS (Netherlands)

    A. Notowicz (Alfred)

    1981-01-01

    textabstractApart from identification of the causative microorganism, serological blood testing is still the principal aid in the diagnosis of venereal syphilis. In latent syphilis it is in fact the only diagnostic aid. In the diagnosis of late symptomatic syphilis, additional organ-specific

  8. Development of a virus neutralisation test to detect antibodies against Schmallenberg virus and serological results in suspect and infected herds

    Directory of Open Access Journals (Sweden)

    Loeffen Willie

    2012-08-01

    Full Text Available Abstract Background At the end of 2011, a new orthobunyavirus, tentatively named Schmallenberg virus (SBV, was discovered in Germany. This virus has since been associated with clinical signs of decreased milk production, watery diarrhoea and fever in dairy cows, and subsequently also with congenital malformations in calves, lambs and goat kids. In affected countries, initial surveillance for the infection was based on examination of malformed progeny. These suspicions were followed up by real-time reverse transcription polymerase chain reaction (RT-PCR on brain tissue. For epidemiological purposes, a serological assay was, however, needed. Results A virus neutralisation test (VNT was developed and optimized, and subsequently evaluated. This VNT has a specificity of >99% and the sensitivity is likely also very close to 100%. The assay is highly repeatable and reproducible. The final assay was used to test for antibodies in cows, ewes and does from herds known to be infected or suspected to be so. Targets for sampling in these herds were the mothers of malformed offspring. In herds with an RT-PCR confirmed SBV infection, more than 94% (190 out of 201 of the ewes and 99% (145 out of 146 of the cows were seropositive. In herds with suspicion of SBV infection based on birth of malformed offspring only (no or negative RT-PCR, more than 90% (231 out of 255 of the ewes and 95% (795 out of 834 of the cows were seropositive. In goats, on the other hand, only a low number of seropositives was found: overall 36.4%, being 16 out of 44 goats tested. Conclusions Given the characteristics of this VNT, it can be used at a relative high throughput for testing of animals for export, surveillance, screening and research purposes, but can also be used as a confirmation test for commercially available enzyme-linked immunosorbent assays (ELISA’s and for (relative quantification of antibodies. Suspicions of SBV infections that were confirmed by RT-PCR were almost

  9. Clinical Application Of Serological Tests For Syphilis

    OpenAIRE

    Lawee, David

    1980-01-01

    This article differentiates and describes the serological tests for syphilis— antitreponemal antibody tests (TPI, FTA-ABS, TPHA), non-treponemal antigen test (VDRL)—their clinical and serological correlation, the responses to therapy and the biologically false positive syndrome.

  10. Helicobacter Pylori : Serological Testing and Treatment in ...

    African Journals Online (AJOL)

    Purpose: Helicobacter pylori has been strongly associated with dyspepsia and eradication of H. pylori after a non-invasive testing is an integral part of most management guidelines. This study evaluated the benefit of serological testing and treatment of H. pylori in Nigerian patients presenting with uninvestigated dyspepsia.

  11. Using standard serology blood tests to diagnose latent syphilis

    Directory of Open Access Journals (Sweden)

    G. L. Katunin

    2016-01-01

    Full Text Available Goal. To conduct a comparative assessment of the results of regulated serological tests obtained as a result of blood tests in patients suffering from latent syphilis. Materials and methods. The authors examined 187 patient medical records with newly diagnosed latent syphilis in FGBU GNTsDK (State Research Center for Dermatology, Venereology and Cosmetology, Health Ministry of the Russian Federation, in 2006-2015. The results of patient blood tests were analyzed with the use of non-treponemal (microprecipitation test/RPR and treponemal (passive hemagglutination test, immune-enzyme assay (IgA, IgM, IgG, IFabs, immunofluorescence test and Treponema pallidum immobilization test serology tests. Results. According to the results of blood tests of latent syphilis patients, the largest number of positive results was obtained as a result of treponemal serology tests such as immune-enzyme assay (100%, passive hemagglutination test (100% and IFabs (100%. The greatest number of negative results was observed in non-treponemal (microprecipitation test/RPR serology tests: in 136 (72.7% patients; evidently positive results (4+ test results were obtained in 8 (4.3% patients only. According to the results of a comparative analysis of blood tests in patients suffering from latent syphilis obtained with the use of treponemal serology tests, the greatest number of evidently positive results (4+ was noted for the passive hemagglutination test (67.9%. Negative treponemal test results were obtained with the use of the immunofluorescence test and Treponema pallidum immobilization test (21.9% and 11.8% of cases, respectively. Moreover, weakly positive results prevailed for the immunofluorescence test: in 65 (34.7% patients. Conclusion. These data confirm that the following treponemal tests belong to the most reliable ones for revealing patients suffering from latent syphilis: immune-enzyme assay, passive hemagglutination test and IFabs.

  12. Factors affecting the serological testing of cadaveric donor cornea

    Directory of Open Access Journals (Sweden)

    Anuradha Raj

    2018-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the serological profile of the eye donors and to study the influence of various factors on serological test results. Methods: A cross-sectional, observational study was conducted, and data of 509 donors were reviewed from the records of eye bank from December 2012 to June 2017. Various details of donors analyzed included the age, sex of the donor, cause of death, source of tissue, time since blood collection after death, macroscopic appearance of blood sample, and details of discarded tissues. Serological examination of blood was performed for human immunodeficiency virus (HIV, hepatitis B virus, hepatitis C virus (HCV, venereal disease research laboratory (VDRL, and serology reports reactive or nonreactive were analyzed. Results: Among the 509 donors, 295 (58% were male, and 420 (82.50% belonged to age group ≥60 years. Most donors (354, 69.5% died due to cardiac arrest. Macroscopically, sera were normal in the majority of 488 (95.9% cases. Among 509 donors, 475 (93.3% were nonreactive, 12 (2.4% donors were found to be reactive to hepatitis B surface antigen (HBsAg, and 1 (0.2% was reactive to HCV, but no donor serology was reactive to HIV or VDRL. Twenty-one (4.12% donors' sera were not fit for serological testing. Among all donors, 475 (93.32% donors were accepted and 34 (6.67% were rejected or discarded on the basis of serological testing. Cause of death and macroscopic aspect of sera influenced the serological results in a highly significant manner (P = 0.00. Acceptance or rejection of the donor was significantly influenced by the serological results of the donor (P = 0.00. Conclusion: The seroprevalence among eye donor for HBsAg and HCV was 12 (2.4% and 1 (0.2%, respectively. Factors such as cause of death and macroscopic aspect of sera influence the serological results. Time since blood collection or sampling will not show any impact on viral serological results if postmortem sampling

  13. Factors affecting the serological testing of cadaveric donor cornea.

    Science.gov (United States)

    Raj, Anuradha; Mittal, Garima; Bahadur, Harsh

    2018-01-01

    The purpose of this study was to evaluate the serological profile of the eye donors and to study the influence of various factors on serological test results. A cross-sectional, observational study was conducted, and data of 509 donors were reviewed from the records of eye bank from December 2012 to June 2017. Various details of donors analyzed included the age, sex of the donor, cause of death, source of tissue, time since blood collection after death, macroscopic appearance of blood sample, and details of discarded tissues. Serological examination of blood was performed for human immunodeficiency virus (HIV), hepatitis B virus, hepatitis C virus (HCV), venereal disease research laboratory (VDRL), and serology reports reactive or nonreactive were analyzed. Among the 509 donors, 295 (58%) were male, and 420 (82.50%) belonged to age group ≥60 years. Most donors (354, 69.5%) died due to cardiac arrest. Macroscopically, sera were normal in the majority of 488 (95.9%) cases. Among 509 donors, 475 (93.3%) were nonreactive, 12 (2.4%) donors were found to be reactive to hepatitis B surface antigen (HBsAg), and 1 (0.2%) was reactive to HCV, but no donor serology was reactive to HIV or VDRL. Twenty-one (4.12%) donors' sera were not fit for serological testing. Among all donors, 475 (93.32%) donors were accepted and 34 (6.67%) were rejected or discarded on the basis of serological testing. Cause of death and macroscopic aspect of sera influenced the serological results in a highly significant manner (P = 0.00). Acceptance or rejection of the donor was significantly influenced by the serological results of the donor (P = 0.00). The seroprevalence among eye donor for HBsAg and HCV was 12 (2.4%) and 1 (0.2%), respectively. Factors such as cause of death and macroscopic aspect of sera influence the serological results. Time since blood collection or sampling will not show any impact on viral serological results if postmortem sampling will be done in donor cornea.

  14. Confirmation of high specificity of an automated enzyme immunoassay test for serological diagnosis of syphilis: retrospective evaluation versus results after implementation.

    Science.gov (United States)

    van Dommelen, Laura; Hoebe, Christian J P A; van Tiel, Frank H; Thijs, Carel; Goossens, Valère J; Bruggeman, Cathrien A; van Loo, Inge H M

    2015-03-01

    The optimal algorithm for serological syphilis screening is still a matter of debate. We have previously evaluated the performance of the Bioelisa Syphilis 3.0, using a selection of archived sera, and in this study compare these results with the Bioelisa results after clinical implementation. All Bioelisa Syphilis 3.0 results obtained since clinical implementation were analyzed. Bioelisa-positive or borderline samples were retested using Treponema pallidum particle agglutination, rapid plasma reagin test, fluorescent treponemal antibody-absorption test, and/or immunoblot. On sera sent in together with cerebrospinal fluid, occasionally both the T. pallidum particle agglutination and Bioelisa were performed. The Bioelisa was performed on 14,622 sera. Bioelisa-positive samples, which were not retested by the previously described assays, were withdrawn from the database (n = 36). In 1.3% of the samples (187/14,586), the Bioelisa was positive or borderline and, ultimately, 115 sera were considered true positive (prevalence 0.8%). The specificity of the Bioelisa was 99.5%. Based on the results of all performed diagnostic assays, the specificity of the Bioelisa of 99.5% is very consistent with that found in the initial study (100%; 95% confidence interval was 98.0%-100%). Interpreting (positive) test results is difficult in the absence of a gold standard, especially when the disease prevalence is low. Results should be viewed in the light of the patients' characteristics.

  15. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  16. HSV Serologic Testing for Pregnant Women: Willingness to Be Tested and Factors Affecting Testing

    Directory of Open Access Journals (Sweden)

    David A. Baker

    2011-01-01

    Full Text Available Objective. This prospective study was undertaken to evaluate pregnant women's willingness to undergo HSV type-specific serologic testing and factors affecting willingness in an obstetrics/gynecology ambulatory unit. Methods. At prenatal Visit 1, pregnant women (n=303 with no history of HSV-2 were tested for HSV-1/HSV-2 before and after they received counseling on genital and neonatal herpes. Results. In both the Unwilling Subgroup and the group that changed from being willing to being unwilling, the most common reasons for choosing not to be tested were not being at risk for genital herpes, being tested is too personal, and concern about what will be done with the results. Of the 134 participants in the Willing/Tested Subgroup, 27 (20% were HSV-2 seropositive and 81 (60% were HSV-1 seropositive. Conclusions. These results support the feasibility of HSV serologic testing and counseling in pregnant women.

  17. Evaluating the utility of serological testing in laryngotracheal stenosis.

    Science.gov (United States)

    Hall, S Ryan; Allen, Clint T; Merati, Albert L; Mayerhoff, Ross M

    2017-06-01

    Whereas mechanical (traumatic) causes of laryngotracheal stenosis (LTS) are identified based on history, autoimmune laryngotracheal stenosis (aLTS) and idiopathic laryngotracheal stenosis (iLTS) are often more difficult to differentiate. The objective of this study was to evaluate serologic testing in a large cohort of nonmechanical LTS patients to determine which tests, if any, lead clinicians to the etiology of the LTS. Retrospective chart review. This study reviewed nonmechanical LTS patients seen at a tertiary medical center from 2007 to 2014. Data were obtained on patient demographics, associated preexisting autoimmune conditions, comorbidities, intubation history, and serologic testing. Ninety-two records were reviewed. Twenty-three (25%) patients were found to have autoimmune disease; 69 (75%) met criteria for iLTS. A history of cigarette smoking was more significant in the aLTS group than the iLTS group (P testing was equivocal between the two cohorts. Differentiating iLTS from aLTS has proven difficult. The lack of information about the two entities has resulted in variability in the diagnostic workup to distinguish them. This study's finding of a more significant smoking history in the aLTS group correlates with the literature, which suggests an inflammatory effect of smoking cigarettes and an association with autoimmune disease. The only significant cohort of patients in this study found to have positive serological testing correlated with a diagnosable condition responsible for LTS was GPA patients with positive ANCA. 4. Laryngoscope, 127:1408-1412, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Impact of Vaccination History on Serological Testing in Pregnant Women.

    Science.gov (United States)

    Desjardins, Michaël; Boucoiran, Isabelle; Paquet, Caroline; Laferrière, Céline; Gosselin-Brisson, Anne; Labbé, Annie-Claude; Martel-Laferrière, Valérie

    2018-04-01

    Serological testing guidelines for vaccine-preventable infectious diseases in pregnant women are heterogeneous. It is unclear how vaccination history influences health care workers' (HCWs) attitudes about testing. The aim of this study was to describe current practices in screening for rubella, hepatitis B, and varicella-zoster virus (VZV) in pregnant women in the province of Québec. In 2015, an electronic survey was distributed to HCWs who followed the case of at least one pregnant woman in the previous year and who could be contacted by email by their professional association. A total of 363 of 1084 (33%) participants were included in the analysis: general practitioners (57%), obstetrician-gynaecologists (20%), midwives (41%), and nurse practitioners (31%). For rubella, 48% of participants inquired about vaccination status, and of these, 98% offered serological testing for unvaccinated women versus 44% for vaccinated women. Similarly, of the 48% of participants who asked about hepatitis B vaccination status before offering testing, 96% ordered testing for hepatitis B surface antigen, 28% ordered testing for hepatitis B surface antibody, and 1% ordered no serological testing to unvaccinated women versus 72%, 46%, and 8%, respectively, for vaccinated women. Among the 81% of respondents who discussed VZV during prenatal care, 13% ordered serological testing if patients had a history of VZV infection, 87% if the VZV history was uncertain, and 19% if patients had a positive history of vaccination. Asking about vaccination status influences HCWs' attitudes about serological testing for rubella, hepatitis B, and VZV. In the context of increasing vaccination coverage in women of child-bearing age, it is important to clarify the impact of vaccination status in serological screening guidelines in pregnant women. Copyright © 2018 Society of Obstetricians and Gynaecologists of Canada. Published by Elsevier Inc. All rights reserved.

  19. Serological IgG avidity test for ocular toxoplasmosis

    Directory of Open Access Journals (Sweden)

    Suresh S

    2012-01-01

    Full Text Available Subramaniam Suresh1, Saidin Nor-Masniwati1, Muhd Nor Nor-Idahriani1, Wan-Hitam Wan-Hazabbah1, Mohamed Zeehaida2, Embong Zunaina11Department of Ophthalmology, 2Department of Medical Microbiology and Parasitology, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, MalaysiaBackground: The purpose of this study was to evaluate the immunoglobulin (Ig G avidity of serological toxoplasmosis testing in patients with ocular inflammation and to determine the clinical manifestations of ocular toxoplasmosis.Methods: A retrospective review of all patients presenting with ocular inflammation to the Hospital Universiti Sains Malaysia, Kelantan, Malaysia between 2005 and 2009 was undertaken. Visual acuity, clinical manifestations at presentation, toxoplasmosis antibody testing, and treatment records were analyzed.Results: A total of 130 patients with ocular inflammation were reviewed retrospectively. The patients had a mean age of 38.41 (standard deviation 19.24, range 6–83 years. Seventy-one patients (54.6% were found to be seropositive, of whom five (3.8% were both IgG and IgM positive (suggestive of recently acquired ocular toxoplasmosis while one (0.8% showed IgG avidity ≤40% (suggestive of recently acquired ocular toxoplasmosis and 65 patients (50.0% showed IgG avidity >40% (suggestive of reactivation of toxoplasmosis infection. Chorioretinal scarring as an ocular manifestation was significantly more common in patients with seropositive toxoplasmosis (P = 0.036. Eighteen patients (13.8% were diagnosed as having recent and/or active ocular toxoplasmosis based on clinical manifestations and serological testing.Conclusion: Ocular toxoplasmosis is a clinical diagnosis, but specific toxoplasmosis antibody testing helps to support the diagnosis and to differentiate between reactivation of infection and recently acquired ocular toxoplasmosis.Keywords: ocular toxoplasmosis, chorioretinal scar, toxoplasmosis antibody, IgG avidity test

  20. The importance of serological tests implementation in disseminated candidiasis diagnose.

    Science.gov (United States)

    Gegić, Merima; Numanović, Fatima; Delibegović, Zineta; Tihić, Nijaz; Nurkić, Mahmut; Hukić, Mirsada

    2013-03-01

    Candidiasis is defined as an infection or disease caused by a fungus of the genus Candida. Rate of disseminated candidiasis increases with the growth of the number of immunocompromised patients. In the the last few decades the incidence of disseminated candidiasis is in growth as well as the mortality rate. The aim of this survey is to show the importance of serological tests implementation in disseminated candidiasis diagnose. This is a prospective study involving 60 patients with malign diseases with and without clinical signs of disseminated candidiasis and 30 healthy people who represent the control group. Apart from hemoculture, detection of circulating mannan antigen and adequate antibodies of Candida species applying comercial ELISA test was determined in each patient. This survey deals with relevant factors causing disseminated candidiasis. This survey showed that the group of patients with clinical signs of disseminated candidiasis had more patients with positive hemoculture to Candida species, then the group of patients without clinical signs of disseminated candidiasis. The number of patients being examined and positive to antigens and antibodies was higher (p candidiasis (7/30; 23.3%), then in the group of patients without clinical signs of disseminated candidiasis (0/30; 0%): Average value of titra antigen was statistically higher (p candidiasis 6/30 (20%) of patients had Candida spp.positive hemocultures while in the group of patients without clinical signs of disseminated candidiasis 1/30 (3.3%) of patients had Candida spp. positive hemocultures, which was considerably higher (p candidiasis were statistically significant, while correlation of results of hemoculture and antibodies was insignificant. Because of low sensitivity of hemoculture and time needed for isolation of Candida spp., introducing serological tests in regular procedures would speed disseminated candidiasis diagnose.

  1. Evaluation of efficacy of some serological tests used for diagnosis of ...

    African Journals Online (AJOL)

    These samples were subjected to the different serological tests including Rose Bengal plate antigen test, Tube Agglutination test, Rivanol test, Indirect Enzyme Linked Immunosorbent Assay and Competitive Enzyme Linked Immunosorbent Assay. Statistical analysis of the obtained results in different cattle groups was ...

  2. Serological Tests for Acquired Syphilis in Immuno-competent Patients

    Directory of Open Access Journals (Sweden)

    Golušin Zoran

    2016-06-01

    Full Text Available Serological tests represent a valuable tool for the diagnosis and monitoring the syphilis treatment. Non-treponemal antibodies are nonspecific to detect the infection, but antibody titers are used to monitor the effects of syphilis treatment. A definitive diagnosis of syphilis is made using treponemal tests, because they detect specific antibodies to the treponemal strains or treponemal fragments, which cause syphilis. These tests may remain reactive for years, sometimes for life, regardless of the therapy outcome. Even after successful treatment, approximately 85% of patients remain positive for treponemal antibodies for the rest of their lives. However, treponemal tests cannot differentiate past infections from a current infection. Therefore, we use a combination of specific and non-specific tests, the two most frequently used diagnostic algorithms. The traditional algorithm begins with a non-treponemal assay, and if it is positive, the treponemal test is done. A positive treponemal test indicates syphilis. The reverse serology algorithm detects early, primary, and treated syphilis that may be missed with traditional screening. However, non-treponemal test is necessary to detect patients with active syphilis.

  3. Poor Positive Predictive Value of Lyme Disease Serologic Testing in an Area of Low Disease Incidence.

    Science.gov (United States)

    Lantos, Paul M; Branda, John A; Boggan, Joel C; Chudgar, Saumil M; Wilson, Elizabeth A; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G; Nigrovic, Lise E

    2015-11-01

    Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%-28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%-4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  4. Positive Result by Serology Indicates Active Helicobacter pylori Infection in Patients with Atrophic Gastritis

    OpenAIRE

    Kokkola, Arto; Rautelin, Hilpi; Puolakkainen, Pauli; Sipponen, Pentti; Färkkilä, Martti; Haapiainen, Reijo; Kosunen, Timo U.

    1998-01-01

    Patients with atrophic corpus gastritis and elevated Helicobacter pylori antibody titers but 13C-urea breath test (13C-UBT) and histology results negative for H. pylori were randomized into eradication therapy or follow-up only. Antibody levels decreased significantly in six out of seven patients in the eradication group, while in the follow-up group, the titers declined in only one out of eight patients. In patients with atrophic corpus gastritis, positive serology results may indicate an on...

  5. Diagnosis of Lyme-associated uveitis: value of serological testing in a tertiary centre.

    Science.gov (United States)

    Bernard, Alexia; Kodjikian, Laurent; Abukhashabh, Amro; Roure-Sobas, Chantal; Boibieux, Andre; Denis, Philippe; Broussolle, Christiane; Seve, Pascal

    2018-03-01

    To determine the frequency and clinical presentation of Lyme disease in patients with uveitis and to assess the value of Borrelia burgdorferi serological testing. Retrospective study on all patients with uveitis who were referred to our tertiary hospital were serologically tested for Lyme in our laboratory between 2003 and 2016. Screening consisted of determining B. burgdorferi serum IgG and IgM by ELISA method. The patient's serology was considered as positive if the ELISA-positive result in IgM and/or IgG was confirmed by an immunoblot positive in IgM and/or IgG. Lyme-associated uveitis was diagnosed based on serological results as well as response to antibiotics and exclusion of other diagnosis. Of the 430 patients with uveitis (60% women, mean age 49 years) fulfilling inclusion criteria, 63 (14.7%) had an ELISA-positive serology, confirmed by immunoblot for 34 patients (7.9%). The diagnosis of Lyme-associated uveitis was finally retained in seven patients (1.6%). These patients reported either a previous exposure including tick bite or forest walks (n=5), symptoms suggestive of Lyme disease (n=5) and resistance to local and/or systemic steroids (n=7). Among the remaining 27 positive patients, 22 had other established aetiologies and 5 other were unclassified. The seroprevalence of B. burgdorferi among our patients with uveitis was 7.9% compared with 6 to 8.5% in the general French population which leads to a low predictive value of serological testing. Its use should be reserved for patients with unexplained uveitis, an exposure history, systemic findings suggestive of Lyme disease and steroids resistance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Change of liver echogenicity in chronic renal failure: Correlation with serologic test and pathologic findings

    International Nuclear Information System (INIS)

    Eun, Hyo Won; Cho, Kyoung Sik; Kim, Jeong Kon; Kim, Jung Hoon

    2002-01-01

    To correlate serologic test and pathologic findings with change of hepatic parenchymal echogenicity on ultrasound (US) in patients with chronic renal failure. From January 1995 to April 2000, among eight hundred eighty four patients with kidney transplantation due to chronic renal failure, sixty seven patients who underwent US-guided liver biopsy were selected. Change of liver echogenicity on US was analyzed, and this change was compared with serologic test and pathologic findings. Among sixty seven patients, pathologic findings of thirty four patients with the normal liver echogenicity on US revealed normal in 15 patients (44%), viral hepatitis in 18 (53%), and liver cirrhosis in one patient (3%). Meanwhile, twenty seven patients with chronic liver disease on US were pathologically confirmed as normal in 13 patients (48%), viral hepatitis in 11 (40%), liver cirrhosis in four patients (11%); six patients with cirrhotic change on US, liver cirrhosis in four patients (67%) and viral hepatitis on two patients (33%). Serologic test of thirty four patients with the normal liver echogenicity on US showed positive HBs Ag in 17 patients (50%), positive anti-HCV Ab in 11 (32%), positive in both HBs Ag and anti-HCV Ab in one (3%), and normal result in five patients (15%). In patients with chronic renal failure, it is nor enough to determine the presence of liver disease only based on change of echogenicity on US. A careful correlation with serologic test and, if needed, pathologic confirmation are recommended for the accurate preoperative evaluation of the liver.

  7. The use of serological tests in combination with the intradermal tuberculin test maximizes the detection of tuberculosis infected goats.

    Science.gov (United States)

    Bezos, Javier; Roy, Álvaro; Infantes-Lorenzo, José Antonio; González, Isabel; Venteo, Ángel; Romero, Beatriz; Grau, Anna; Mínguez, Olga; Domínguez, Lucas; de Juan, Lucía

    2018-05-01

    The diagnosis of tuberculosis (TB) in goats is based mainly on the single and comparative intradermal tuberculin (SIT and CIT) tests and, exceptionally, on the interferon-gamma (IFN-γ) assay, however they are not perfect in terms of sensitivity and specificity. Nevertheless, various serological assays that provide a potential cost-effective approach for the control of TB are also available or under development, and a variety of results have been reported regarding the ability of these tests to detect infected animals, particularly in the early stages of infection. In the present study, SIT/CIT and IFN-γ tests and three different serological assays were evaluated during two consecutive herd testing events in a recently infected caprine herd (n = 447) with a high prevalence of infection in order to evaluate their performance and provide field data with which to improve the TB control programs in this species. The proportion of infected animals that tested positive among all the infected goats (T+/I+ value) in the last herd testing event ranged from 26.2% (IC95%; 19.3-34.5) to 85.7% (IC95%; 78.5-90.7) using cell-based diagnostic tests. The SIT/SCIT tests detected more infected goats than the IFN-γ test, regardless of the interpretation criteria. The T+/I+ value of serology was 83.2 (IC95%; 75.2-89), although it increased significantly (P test (100%, IC95%; 97-100). In general, a parallel interpretation of intradermal tests with serology maximized the detection of infected goats. These results demonstrate that serological tests are valuable diagnostic tools to maximize the detection of TB infected goats, even in recent outbreaks, accelerating the eradication process. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Diagnostic impact of routine Lyme serology in recent-onset arthritis: results from the ESPOIR cohort

    Science.gov (United States)

    Guellec, Dewi; Narbonne, Valérie; Cornec, Divi; Marhadour, Thierry; Varache, Sophie; Dougados, Maxime; Daurès, Jean Pierre; Jousse-Joulin, Sandrine; Devauchelle-Pensec, Valérie; Saraux, Alain

    2016-01-01

    Objectives Lyme disease may be considered by rheumatologists in patients with recent-onset arthritis, even in the absence of suggestive symptoms. The aim of this study was to determine the diagnostic impact of routine Lyme serology in a French cohort of patients with recent-onset arthritis affecting at least 2 joints. Methods We performed an ancillary study of a French prospective multicentre cohort established to monitor clinical, biological and radiographic data in patients with inflammatory arthritis in at least 2 joints, lasting for 6 weeks to 6 months. Borrelia IgM and IgG antibodies were sought routinely at baseline, using ELISA tests, independently from the physician's strategy for detecting a spirochetal infection. We recorded the proportion of patients with a final diagnosis of Lyme arthritis and evaluated the diagnostic performance of Lyme serology in this particular context. The clinical and biological characteristics of patients according to the Lyme serology results were analysed. Results Of 810 patients, 657 (81.1%) were negative for IgM and IgG antibodies, 91 (11.2%) had only IgM antibodies, 49 (6%) had only IgG antibodies, and 13 (1.6%) had IgG and IgM antibodies. Thus, 7.6% had IgG positivity, consistent with exposure to Borrelia infection. IgG positivity was significantly more prevalent in the North and North-East regions of France (χ2=14.6, pLyme arthritis. Conclusions This study does not support routine Lyme serological testing in patients with recent-onset inflammatory arthritis affecting more than 1 joint. PMID:26819751

  9. The diagnostic accuracy of serological tests for Lyme borreliosis in Europe

    DEFF Research Database (Denmark)

    Leeflang, M M G; Ang, C W; Berkhout, J

    2016-01-01

    -eight studies evaluating an Enzyme-Linked ImmunoSorbent assay (ELISA) or an immunoblot assay against a reference standard of clinical criteria were included. None of the studies had low risk of bias for all QUADAS-2 domains. Sensitivity was highly heterogeneous, with summary estimates: erythema migrans 50 % (95......BACKGROUND: Interpretation of serological assays in Lyme borreliosis requires an understanding of the clinical indications and the limitations of the currently available tests. We therefore systematically reviewed the accuracy of serological tests for the diagnosis of Lyme borreliosis in Europe....... We used a hierarchical summary ROC meta-regression method for the meta-analyses. Potential sources of heterogeneity were test-type, commercial or in-house, Ig-type, antigen type and study quality. These were added as covariates to the model, to assess their effect on test accuracy. RESULTS: Seventy...

  10. Assessment of performance of selected serological tests for diagnosing brucellosis in pigs.

    NARCIS (Netherlands)

    Munoz, P.M.; Blasco, J.M.; Engel, B.; Miguel, de M.J.; Marín, C.M.; Dieste, L.; Mainar-Jaime, R.C.

    2012-01-01

    Swine brucellosis due to Brucella suis is considered an emerging zoonotic disease whose control is based on serological testing and the subsequent culling of seropositive animals or the full depopulation of affected flocks. Here we assessed the performance of several serological tests (Rose Bengal

  11. CORRELATION OF ULTRASOUND (USG FINDINGS WITH SEROLOGICAL TESTS IN DENGUE FEVER

    Directory of Open Access Journals (Sweden)

    Dayanand

    2016-02-01

    Full Text Available INTRODUCTION Dengue is an endemic and epidemic disease of the tropical and subtropical regions. Between September & October 2012, there was an established outbreak of dengue in Hoskote, near Bangalore. Dengue results in serositis, which can be imaged by ultrasonography. OBJECTIVE To correlate the USG findings with the serological tests in paediatric and adult patients. MATERIALS AND METHODS 110 patients with clinical suspicion of dengue fever during the above period underwent serological tests-NS1, IgM and IgG and were evaluated with USG of the abdomen and thorax. The USG findings were correlated with serological tests. RESULTS 67 Patients were seropositive, 43 were seronegative. The USG findings in seropositive paediatric patients (n=32 and adult patients (n=35 respectively were gall bladder (GB wall edema-27 & 31, hepatomegaly-12 &14, ascites-16 & 12, splenomegaly- 15 & 9, right pleural effusion-14 & 13, left and bilateral pleural effusion-7 & 5. CONCLUSION In our study GB wall edema significantly correlated with seropositivity (p value=0.032. Thus ultrasound is an efficient screening tool in a case of dengue outbreak.

  12. Comparison of 2 molecular assays and a serologic test in diagnosing Mycoplasma pneumoniae infection in paediatrics patients.

    Science.gov (United States)

    Blanco, Silvia; Fuenzalida, Loreto; Bas, Albert; Prat, Cristina; Ramírez, Aida; Matas, Lurdes; Rodrigo, Carlos; Ausina, Vicente

    2011-12-01

    Two commercial polymerase chain reaction (PCR) assays (a real-time PCR [Cepheid] and an oligochromatographic test [Speed-oligo]) and 1 serology test (Serodia-Myco II) for detecting Mycoplasma pneumoniae in nasopharyngeal aspirates and serum samples were studied. Among the 145 samples, 32 serum pairs were serologically positive for M. pneumoniae. Of these, in 30 nasopharyngeal aspirates, M. pneumoniae was detected using the real-time PCR assay and 25 using Speed-oligo, corresponding to a sensitivity of 93.7% and 78.1%, respectively. Among the 94 samples with negative serology, we only obtained 1 positive result by real-time PCR assay. In the group of samples from healthy children, no positive results were obtained. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Appropriateness of laboratory tests: requests for atypical pneumonia serology in a teaching hospital.

    LENUS (Irish Health Repository)

    Jackson, L M

    2012-02-03

    The cost of providing medical care is ever-increasing but the resources available are at best static. Major savings can be made by reducing inappropriate investigations. Using serological testing for organisms causing atypical pneumonia as an example, we examined the appropriateness of requests and also physicians\\' understanding of the test. Of 119 patients tested, only 3 had titres indicative of acute infection. Most patients were tested within 2 days of hospital admission, before receipt of results excluding more likely diagnoses. Forty-five patients had no current or recent respiratory symptoms, in whom infection was highly unlikely. Titres were most often requested by the least experienced members of the clinical team. Of 70 patients with an acute illness in whom a definitive diagnosis, bacteriological or otherwise, was not made, in only 9 was a convalescent specimen sent for follow-up titres. Most requests for serology for organisms causing atypical pneumonia were inappropriate. Furthermore, in the majority of cases the test was incorrectly used.

  14. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  15. Serological cross-reactivity of Trypanosoma cruzi, Ehrlichia canis, Toxoplasma gondii, Neospora caninum and Babesia canis to Leishmania infantum chagasi tests in dogs

    Directory of Open Access Journals (Sweden)

    Maurício Franco Zanette

    2014-01-01

    Full Text Available Introduction: The aim of this study was to evaluate the serological cross-reactivity between Leishmania sp. and other canine pathogens. Methods: Positive serum samples for Ehrlichia canis, Babesia canis, Toxoplasma gondii, Neospora caninum and Trypanosoma cruzi were tested using three serological methods enzyme linked immunosorbent assay (ELISA, indirect immunofluorescent antibody test (IFAT and Kalazar Detect™, for canine visceral leishmaniasis. Results: Of the 57 dog samples tested, 24 (42.1% tested positive using one of the three serological methods: 10/57 (17.5% for ELISA, 11/57 (19.3% for IFAT and 3/57 (5.3% for Kalazar Detect™. Conclusions: Our results demonstrated that the presence of other infectious agents may lead to cross-reactivity on leishmaniasis serological tests.

  16. Diagnostic value of serologic tests in celiac screening

    Directory of Open Access Journals (Sweden)

    Hosein Saneian

    2012-01-01

    Conclusions: According to our study results, there is no correlation between gastrointestinal symptoms such as vomiting diarrhea, anorexia, bulimia, and failure to thrive (FFT with celiac. TTG was the best screening test method to diagnose celiac disease and other tests such as AGA and EMA do not have high diagnostic value.

  17. Diagnostic Value of Culture and Serological Tests in the Diagnosis of Histoplasmosis in HIV and non-HIV Colombian Patients

    Science.gov (United States)

    Arango-Bustamante, Karen; Restrepo, Angela; Cano, Luz Elena; de Bedout, Catalina; Tobón, Angela Maria; González, Angel

    2013-01-01

    We determined the value of culture and serological tests used to diagnose histoplasmosis. The medical records of 391 histoplasmosis patients were analyzed. Diagnosis of the mycosis was assessed by culture, complement fixation, and immunodiffusion tests; 310 patients (79.5%) were male, and 184 patients (47.1%) were infected with human immunodeficiency virus (HIV). Positivity value for cultures was 35.7% (74/207), reactivity of serological tests was 95.2% (160/168), and a combination of both methodologies was 16.9% (35/207) for non-HIV patients. Positivity value for cultures was 75.0% (138/184), reactivity of serological tests was 92.4% (85/92), and a combination of both methodologies was 26.0% (48/184) for HIV/acquired immunodeficiency syndrome (AIDS) patients; 48.1% (102/212) of extrapulmonary samples from HIV/AIDS patients yielded positive cultures compared with 23.1% (49/212) in non-HIV patients. Lymphocyte counts made for 33.1% (61/184) of HIV/AIDS patients showed a trend to low CD4+ numbers and higher proportion of positive cultures. These results indicate that culture is the most reliable fungal diagnostic method for HIV/AIDS patients, and contrary to what is generally believed, serological assays are useful for diagnosing histoplasmosis in these patients. PMID:24043688

  18. Seroprevalence of human brucellosis in and around Jammu, India, using different serological tests

    Directory of Open Access Journals (Sweden)

    H. K. Sharma

    2016-07-01

    Full Text Available Aim: Brucellosis is a disease of zoonotic importance as it affects both human as well as animal’s health, and therefore, directly affects animal productivity and human efficiency. Therefore, a study was conducted to estimate the seroprevalence of brucellosis in humans in Jammu and surrounding areas. Materials and Methods: A total of 121 sera samples from humans occupied with professional related to animals were collected and tested for anti-Brucella antibodies by Rose Bengal plate test (RBPT, modified RBPT (mRBPT, standard tube agglutination test (STAT, and indirect enzyme-linked immunosorbent assay (I-ELISA. Sampling was done keeping in view with the occupation, sex, and age. Results: The overall seroprevalence of brucellosis recorded was 4.96%. The test-wise seroprevalence was 9.91% by RBPT, 9.91% by mRBPT, 9.09% by STAT, and 16.52% by I-ELISA. The prevalence of brucellosis was higher in >35-50 years age group compared to >20-35 years and >50-65 years. Sex-wise seroprevalence was higher in males than females. Taking I-ELISA as standard, the relative sensitivities of mRBPT, RBPT, and I-ELISA were in the order of mRBPT=RBPT>STAT. All the tests revealed high specificity values; however, among different serological tests, I-ELISA detected a maximum number of positive sera samples. Conclusions: The prevalence of brucellosis was found to be approximately 5%. The adult (>35-50 years age male group was most vulnerable. The routine diagnosis of brucellosis involved the conventional serological tests, viz., RBPT and STAT, but each was associated with drawbacks which could give either false-positive or false-negative interpretation. Therefore, it is always recommended to use a battery of tests in the diagnosis of brucellosis.

  19. A simple kit for rapid field diagnosis of potato virus Y by latex serological test

    Directory of Open Access Journals (Sweden)

    Aarne Kurppa

    1987-07-01

    Full Text Available A simple kit for rapid detection of potato virus Y by latex serological test was developed. The test is carried out on a white cardboard sheet and the results can be read by naked eye in two minutes. A test card of 10 x 6 cm holds latex sensitized antibodies, buffers and other necessary ingredients as dry blue colored formulate on the ringed areas of the card. A test card includes space for six tests and positive and negative controls. The kit also includes disposable plastic sticks for mixing the samples with test reagents and a hand press with disposable plastic tips. For testing, dried reagents are dissolved in drops of sample and mixed. After gentle rotation, samples containing virus appear clearly granulated while samples from healthy plants remain unagglutinated. The testing of undiluted extracts of evenly developed tuber sprouts resulted in over 91 % identity with the results obtained with ELISA that was used as a control method. Testing of diluted leaf extracts reached the same reliability but undiluted leaf extracts from glasshouse grown potatoes were not well suitable as test samples because of their dark green color. No such problems occurred with field grown material and a complete identity with the ELISA readings was true when the samples included secondarily infected potato plants. No reaction to other potato viruses than PVY was obtained by the test kit.

  20. Pros and Cons of serological testing in syphilis diagnosis and follow up

    Directory of Open Access Journals (Sweden)

    Gino Ciarrocchi

    2010-03-01

    Full Text Available Since a proper diagnosis of syphilis is often difficult due to the wide variability of both clinical picture and laboratory test results, early recognition of infection caused by Treponema pallidum is crucial for a timely and effective treatment. In most cases, definitive diagnosis relies upon serological testing. A screening ELISA test, coupled with a quantitative RPR test and specific IgM antibodies detection, is currently regarded as the basic diagnostic procedure. In addition, a quantitative particle agglutination TP-PA test, FTA-abs IgG test and, eventually, a western-blot IgG and IgM test, allow to achieve a whole serological pattern for each patient at the time of first diagnosis. In this study, a group of serum samples (n=107 and cerebro-spinal fluid (n=3 were retrospectively analyzed using the above mentioned tests. A population of 19 patients whose clinical picture was unremarkable for syphilis, showed border-line values at screening and negative results on confirmation tests. Thirty-three out of 91 luetic patients were diagnosed as primary or early secondary syphilis, 36 as latent syphilis, 3 as neurosyphilis, and 3 were neonates with passive specific immunization. Quantitative RPR test and detection of specific IgM antibodies exhibited extremely high values in all 33 primary syphilis patients; a whole positive luetic pattern was also obtained by confirmation tests. Searching for IgM antibodies, a capture elisa test compared with a single device rapid elisa test showed an overall concordance of 98.1%. In luetic patients other than primary syphilis, quantitative RPR test and detection of specific IgM antibodies provided less relevant values and a low prevalence pattern, whereas TP-PA and FTA-abs tests showed persistent positives results. In the follow up of 19 initially treated patients, quantitative RPR values and specific IgM antibodies index showed a slow, progressive decrease until negative. Conclusion: a comprehensive initial

  1. A review of serological tests used in the diagnosis of Brucellosis ...

    African Journals Online (AJOL)

    Brucellosis is of serious economic importance in livestock and in humans. There are batteries of serological tests developed and in use for the diagnosis of brucellosis in human and livestock Brief history, merits and demerits of some of these test are enumerated in this review. The purpose of the review is to bring together in ...

  2. Utility of testing patients, on presentation, for serologic features of celiac disease.

    Science.gov (United States)

    Srinivas, Melpakkam; Basumani, Pandurangan; Podmore, Geoff; Shrimpton, Anna; Bardhan, Karna Dev

    2014-06-01

    Celiac disease shares features of other disorders. It can be diagnosed conclusively only based on duodenal histology analysis, which is not practical for screening purposes. Serologic analysis might be used to identify candidates for biopsy analysis. We aimed to develop a simple diagnostic approach that all clinicians could follow to increase the percentage of patients accurately diagnosed with celiac disease at initial presentation. We performed a retrospective analysis of data from 752 patients (88 with celiac disease, none were IgA deficient) who attended a UK district general hospital from January 2007 through December 2008 and underwent biopsy analysis and serologic tests to measure endomyseal antibodies and IgA antibodies against tissue transglutaminase (tTG). Patients avoiding gluten in their diet were excluded. Patients were assigned to 1 of 4 groups: high-risk (based on presence of anemia, chronic diarrhea, unintentional weight loss, or dermatitis herpetiformis), low-risk (based on such factors as dyspepsia, abnormal liver function, ataxia, or chronic cough), nutrient deficiency (based on levels of iron, vitamins B12 and D, or folate), or screening (because they had type 1 diabetes or a family history of celiac disease). Patients with celiac disease were identified using the modified Marsh criteria (grades 1-3) for interpreting duodenal histology. We compared clinical category, serology profiles, and biopsy results between patients with and without celiac disease. Celiac disease was diagnosed in 64 of 565 patients in the high-risk group (11%), 14 of 156 patients in the low-risk group (9%; P = .47 compared with high-risk group), 7 of 28 patients in the nutrient-deficiency group, and 3 of 3 patients in the screening group. Among 71 patients who tested positive for both antibodies (tTG and endomyseal antibodies), the positive predictive value for celiac disease was 97%; a negative test result for tTG had a negative predictive value of 98%. Among 708 patients

  3. The diagnostic accuracy of serological tests for Lyme borreliosis in Europe: a systematic review and meta-analysis.

    Science.gov (United States)

    Leeflang, M M G; Ang, C W; Berkhout, J; Bijlmer, H A; Van Bortel, W; Brandenburg, A H; Van Burgel, N D; Van Dam, A P; Dessau, R B; Fingerle, V; Hovius, J W R; Jaulhac, B; Meijer, B; Van Pelt, W; Schellekens, J F P; Spijker, R; Stelma, F F; Stanek, G; Verduyn-Lunel, F; Zeller, H; Sprong, H

    2016-03-25

    Interpretation of serological assays in Lyme borreliosis requires an understanding of the clinical indications and the limitations of the currently available tests. We therefore systematically reviewed the accuracy of serological tests for the diagnosis of Lyme borreliosis in Europe. We searched EMBASE en MEDLINE and contacted experts. Studies evaluating the diagnostic accuracy of serological assays for Lyme borreliosis in Europe were eligible. Study selection and data-extraction were done by two authors independently. We assessed study quality using the QUADAS-2 checklist. We used a hierarchical summary ROC meta-regression method for the meta-analyses. Potential sources of heterogeneity were test-type, commercial or in-house, Ig-type, antigen type and study quality. These were added as covariates to the model, to assess their effect on test accuracy. Seventy-eight studies evaluating an Enzyme-Linked ImmunoSorbent assay (ELISA) or an immunoblot assay against a reference standard of clinical criteria were included. None of the studies had low risk of bias for all QUADAS-2 domains. Sensitivity was highly heterogeneous, with summary estimates: erythema migrans 50% (95% CI 40% to 61%); neuroborreliosis 77% (95% CI 67% to 85%); acrodermatitis chronica atrophicans 97% (95% CI 94% to 99%); unspecified Lyme borreliosis 73% (95% CI 53% to 87%). Specificity was around 95% in studies with healthy controls, but around 80% in cross-sectional studies. Two-tiered algorithms or antibody indices did not outperform single test approaches. The observed heterogeneity and risk of bias complicate the extrapolation of our results to clinical practice. The usefulness of the serological tests for Lyme disease depends on the pre-test probability and subsequent predictive values in the setting where the tests are being used. Future diagnostic accuracy studies should be prospectively planned cross-sectional studies, done in settings where the test will be used in practice.

  4. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India

    Directory of Open Access Journals (Sweden)

    Kiran Pote

    2018-01-01

    Full Text Available Background: Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. Methodology: The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. Results: We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15 than IgM IFA (sensitivity 96.8% and specificity 99.7% for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38% which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. Conclusion: IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  5. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    Science.gov (United States)

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  6. 9 CFR 130.16 - User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at authorized sites. 130.16 Section 130.16 Animals... USER FEES § 130.16 User fees for veterinary diagnostic serology tests performed at NVSL (excluding...

  7. [Analysis for serological diagnostic results of syphilis among entry personnel in Beijing port during 2012-2014].

    Science.gov (United States)

    Feng, M X; Sun, F J; Wang, F; Wang, K L; Liu, M

    2016-06-18

    To analyze the results of syphilis specific serological tests among entry personnel in Beijing port during year 2012-2014 in order to provide evidence for the prevention and control of syphilis. Demographics data and syphilis specific test results of entry personnel were obtained from the information system of Beijing International Travel Healthcare Center and input into Excel 2016. Database for entry personnel was built up accordingly and was analyzed by IBM SPSS22.0. The number of entry personnel in Beijing port during year 2012-2014 was 106 302 person-time. According to the evaluation criteria, 71 308 persons were recruited and analyzed, of whom 277 were tested serologically positive and the total prevalence was 0.39% (95% CI: 0.34%-0.43%). The prevalence was highest in the persons aged 40-49 years (0.81%) and was higher in males (0.50%) than in females (0.23%). The persons from Africa held higher prevalence (1.27%) than from other five regions. As multivariate logical regression analysis indicated that the risk of syphilis infection was 10.38 times more in the persons aged 40-49 years than in the persons 0.05). Twenty-seven seropositive cases were found within 6 246 entry persons who were tested repeatedly during the research period, 9 of which were seroconversion cases so that the cumulative conversion rate was 0.14% (9/6 228). The average conversion time was (6.3±3.0) months. There was no statistical significance between the cumulative seroconversion rates of the persons with different genders and nationalities (P of Fisher's exact test>0.05). Serological detection of syphilis for entry personnel in Beijing port and syphilis-related health education should be reinforced to reduce the risk of disease importing and spreading, protect susceptible subjects and promote health.

  8. Clinical Utility of Serologic Testing for Celiac Disease in Asymptomatic Patients

    Science.gov (United States)

    2011-01-01

    Executive Summary Objective The objective of this evidence-based analysis was to evaluate the clinical utility of serologic testing for celiac disease in asymptomatic individuals presenting with one of the non-gastrointestinal conditions evaluated in this report. The clinical utility was based on the effects of a gluten-free diet (GFD) on outcomes specific to each of these conditions. The prevalence of celiac disease in asymptomatic individuals and one of these non-gastrointestinal conditions was also evaluated. Clinical Need and Target Population Celiac Disease Celiac disease is an autoimmune disease characterized by a chronic inflammatory state of the proximal small bowel mucosa accompanied by structural and functional changes. Technology Under Evaluation Serologic Tests for Celiac Disease There are a number of serologic tests for celiac disease available. Serologic tests are automated with the exception of the anti-endomysial antibody test, which is more time-consuming and operator-dependent than the other tests. Research Questions What is the prevalence of asymptomatic celiac disease in patients presenting with one of the non-gastrointestinal conditions evaluated? What is the effect of the gluten-free diet on condition-specific outcomes in patients with asymptomatic celiac disease presenting with one of the non-gastrointestinal conditions evaluated? What is the clinical utility of serologic testing for celiac disease in asymptomatic patients presenting with one of the non-gastrointestinal conditions evaluated? The clinical utility was defined as the impact of the GFD on disease specific outcomes. What is the risk of all-cause mortality and lymphoma in individuals with asymptomatic celiac disease? What is the budget impact of serologic testing for celiac disease in asymptomatic subjects presenting with one of the non-gastrointestinal conditions evaluated? Research Methods Study Population The study population consisted of individuals with newly diagnosed celiac

  9. Sensitivity and specificity of parallel or serial serological testing for detection of canine Leishmania infection

    Directory of Open Access Journals (Sweden)

    Mauro Maciel de Arruda

    2016-01-01

    Full Text Available In Brazil, human and canine visceral leishmaniasis (CVL caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA and indirect immunofluorescence assays (IFA as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA, decreased sensitivity (83.3% and increased specificity (92.5% were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

  10. Diagnostic validation of selected serological tests for detecting scrub typhus.

    Science.gov (United States)

    Koraluru, Munegowda; Bairy, Indira; Varma, Muralidhar; Vidyasagar, Sudha

    2015-07-01

    Clinical diagnosis of scrub typhus is often difficult because the symptoms are very similar to those of other febrile illness such as dengue, leptospirosis, malaria and other viral hemorrhagic fevers. Though better diagnostic tests are available for rickettsial diseases and scrub typhus elsewhere, the Weil-Felix test is still commonly used in India, mainly because microimmunofluorescence assays (M-IFA) were not available in India till recently and relevant staff had insufficient training. The present study was performed to investigate the performance of M-IFA, IgM ELISA, and Weil-Felix test on 546 non-repeated serum samples from subjects suspected of having scrub typhus. One hundred and forty-three of these 546 samples were positive by M-IFA; these cases were also confirmed clinically to have scrub typhus based on their dramatic responses to doxycycline therapy. IgM ELISA was positive in 122 of the 143 M-IFA positive cases and the Weil-Felix test in 96. Though the Weil-Felix test is a heterophile agglutination test, it was found in this study to have good specificity but far too little sensitivity to use as a routine diagnostic test. IgM ELISA can be a good substitute for M-IFA. Incorporation of multiple prototype antigens on M-IFA slides is likely one of the reasons for its superior performance. As newer and better diagnostic assays become available for scrub typhus diagnosis in developed countries, it will be imperative to also use such tests in other endemic countries to prevent over- or under-diagnosis of scrub typhus. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.

  11. BrucellaCapt versus classical tests in the serological diagnosis and management of human brucellosis.

    Science.gov (United States)

    Casanova, Aurora; Ariza, Javier; Rubio, Manuel; Masuet, Cristina; Díaz, Ramón

    2009-06-01

    The BrucellaCapt test is an immunocapture agglutination test suggested as a possible substitute for the Coombs test in the diagnosis of human brucellosis. Here it is compared with classical tests using 321 samples from 48 patients with brucellosis (6.9 +/- 1.7 samples per patient), including 20 patients with focal disease and 8 patients with a total of 9 relapse episodes (mean follow-up, 18 months). The BrucellaCapt test was used according to the manufacturer's instructions, and we also used a variant of the BrucellaCapt test in which the microtiter plates were not coated with antibodies against total human immunoglobulin (BCAPV). The correlation between the BrucellaCapt and BCAPV tests was 0.982 (P < 0.001), with 260 coincident pairs of titers (81%). The areas under the receiver operating characteristic curve for the BrucellaCapt and BCAPV tests with respect to the Coombs test were 0.969 and 0.960, respectively. Upon admission, the BrucellaCapt, BCAPV, and Coombs tests and the microagglutination test (MAT) were positive for all cases: titers were 1/2,560 by the BrucellaCapt test, 1/2,560 by the BCAPV test, 1/1,280 by the Coombs test, and 1/320 by the MAT. The decreases in the BrucellaCapt and BCAPV titers over time were pronounced in comparison with the Coombs titers. Cumulative probabilities of persistence 12 months after therapy were as follows: 80% by the BrucellaCapt test, 80% by the BCAPV test, 87% by the Coombs test, and 35% by the MAT. Serological changes during relapse were detected in seven cases (88%) by the Coombs test, in five cases by the BrucellaCapt and BCAPV tests, and in three cases by the MAT. The BrucellaCapt test is a sensitive, specific, and simple test for routine use in human brucellosis. Similar results were obtained with the BCAPV test. However, in some cases of relapse and chronic forms of the disease, the slight changes observed in low-affinity antibodies alone are better detected by the Coombs test.

  12. Serological Testing in Screening for Adult Celiac Disease

    Directory of Open Access Journals (Sweden)

    Helen Rachel Gillett

    1999-01-01

    Full Text Available Assays for celiac-related antibodies are becoming widely available, and the present review aims to clarify the use of these investigations in the diagnosis of, management of and screening for adult celiac disease. The sensitivities and specificities of various antibody tests are discussed, along with their clinical use as an adjunct to small bowel biopsy, and as a first-line investigation for patients with atypical symptoms of celiac disease or patients at high risk of developing sprue.

  13. Evaluation of serological tests for detecting tick-borne encephalitis virus (TBEV) antibodies in animals.

    Science.gov (United States)

    Klaus, Christine; Beer, Martin; Saier, Regine; Schubert, Harald; Bischoff, Sabine; Süss, Jochen

    2011-01-01

    Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.

  14. Serum neutralization as a differential serological test for classical swine fever virus and other pestivirus infections

    Directory of Open Access Journals (Sweden)

    Paredes J.C.M.

    1999-01-01

    Full Text Available Serum neutralization tests (SN were performed against classical swine fever virus (CSFV, bovine viral diarrhea virus (BVDV and border disease virus (BDV on samples of swine serum collected for screening of antibodies to CSFV, in order to determine the SN value as a differential serological test. Ninety-nine sera out of a sample of 16,664 were positive for antibodies to pestiviruses in an ELISA test which did not distinguish antibodies to different pestiviruses. When submitted to SN, 81 sera were positive for CSFV antibodies only. In 17 sera, crossreactive antibodies to either CSFV, BVDV or BDV were detected. In most of these sera (13 out of 17 the differences between SN titres against the three viruses were not sufficient to estimate which was the most likely antibody-inducing virus. It was concluded that, for the SN to be useful in such differentiation, it is essential to examine a sample which must include a representative number of sera from the same farm where suspect animals were detected. When isolated serum samples are examined, such as those obtained with the sampling strategy adopted here, the SN may give rise to inconclusive results.

  15. Rapid Quantitative Serological Test for Detection of Infection with Mycobacterium leprae, the Causative Agent of Leprosy

    Science.gov (United States)

    Balagon, Marivic F.; Maghanoy, Armi; Orcullo, Florenda M.; Cang, Marjorie; Dias, Ronaldo Ferreira; Collovati, Marco; Reed, Steven G.

    2014-01-01

    Leprosy remains an important health problem in a number of regions. Early detection of infection, followed by effective treatment, is critical to reduce disease progression. New sensitive and specific tools for early detection of infection will be a critical component of an effective leprosy elimination campaign. Diagnosis is made by recognizing clinical signs and symptoms, but few clinicians are able to confidently identify these. Simple tests to facilitate referral to leprosy experts are not widely available, and the correct diagnosis of leprosy is often delayed. In this report, we evaluate the performance of a new leprosy serological test (NDO-LID). As expected, the test readily detected clinically confirmed samples from patients with multibacillary (MB) leprosy, and the rate of positive results declined with bacterial burden. NDO-LID detected larger proportions of MB and paucibacillary (PB) leprosy than the alternative, the Standard Diagnostics leprosy test (87.0% versus 81.7% and 32.3% versus 6.5%, respectively), while also demonstrating improved specificity (97.4% versus 90.4%). Coupled with a new cell phone-based test reader platform (Smart Reader), the NDO-LID test provided consistent, objective test interpretation that could facilitate wider use in nonspecialized settings. In addition, results obtained from sera at the time of diagnosis, versus at the end of treatment, indicated that the quantifiable nature of this system can also be used to monitor treatment efficacy. Taken together, these data indicate that the NDO-LID/Smart Reader system can assist in the diagnosis and monitoring of MB leprosy and can detect a significant number of earlier-stage infections. PMID:24478496

  16. Accuracy of Herdsmen Reporting versus Serologic Testing for Estimating Foot-and-Mouth Disease Prevalence

    Science.gov (United States)

    Handel, Ian G.; Tanya, Vincent N.; Hamman, Saidou M.; Nfon, Charles; Bergman, Ingrid E.; Malirat, Viviana; Sorensen, Karl J.; Bronsvoort, Barend M. de C.

    2014-01-01

    Herdsman-reported disease prevalence is widely used in veterinary epidemiologic studies, especially for diseases with visible external lesions; however, the accuracy of such reports is rarely validated. Thus, we used latent class analysis in a Bayesian framework to compare sensitivity and specificity of herdsman reporting with virus neutralization testing and use of 3 nonstructural protein ELISAs for estimates of foot-and-mouth disease (FMD) prevalence on the Adamawa plateau of Cameroon in 2000. Herdsman-reported estimates in this FMD-endemic area were comparable to those obtained from serologic testing. To harness to this cost-effective resource of monitoring emerging infectious diseases, we suggest that estimates of the sensitivity and specificity of herdsmen reporting should be done in parallel with serologic surveys of other animal diseases. PMID:25417556

  17. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  18. Clinical and serological tests for arboviruses in free-living domestic pigeons (Columba livia).

    Science.gov (United States)

    Ramos, Bruna Alves; Chiang, Jannifer Oliveira; Martins, Lívia Carício; Chagas, Liliane Leal das; Silva, Franko de Arruda E; Ferreira, Milene Silveira; Freitas, Maria Nazaré Oliveira; Alcantara, Bianca Nascimento de; Silva, Sandro Patroca da; Miranda, Stefânia Araújo; Sepulvreda, Barbara Alves; Corrêa, Layna Thayssa Guimarães; Negrão, Andréa Maria Góes; Vasconcelos, Pedro Fernando da Costa; Casseb, Alexandre do Rosário

    2017-08-01

    In this study, we evaluated the role of free-living domestic pigeons (Columba livia) as a reservoir of arboviruses in the city of Belém, state of Pará, Brazil. We investigated the presence of antibodies against the most prevalent arboviruses. This study was aimed at evaluating some clinical and physical parameters of domestic pigeons, including the presence of antibodies to Amazon-endemic arboviruses. Eighty-five healthy pigeons were captured in Mangal das Garças Park, in Belém, and were bled. Upon capture, the birds were subjected to a clinical examination in search of alterations that could indicate the presence of arboviruses. Blood samples were converted to serum and tested using the haemagglutination inhibition (HI) technique with a panel of 19 antigens of arboviruses circulating in the Amazon. The confirmation assay for the positive reactions to the viral species tested by HI was a neutralisation test in new-born Swiss albino mice (Mus musculus) [mouse neutralisation test (MNT)]. A total of 10 (11.8%) serum samples tested positive for antiflavivirus antibodies by HI. All the samples positive for the HI test were subjected to MNT for detection of viruses and yielded negative results (logarithmic neutralisation index < 1.7). The results represent the first serological detection of antiarbovirus antibodies in domestic pigeons as potential hosts of arboviruses in Brazil. The detection of haemagglutination-inhibiting antibodies against genus Flavivirus indicated that there was recent contact between the analysed domestic pigeons and these arboviruses. Further studies are needed to evaluate the role of free-living pigeons in the maintenance cycle and spread of arboviruses in the Amazon.

  19. Integrative literature review of the reported uses of serological tests in leprosy management.

    Science.gov (United States)

    Fabri, Angélica da Conceição Oliveira Coelho; Carvalho, Ana Paula Mendes; Vieira, Nayara Figueiredo; Bueno, Isabela de Caux; Rodrigues, Rayssa Nogueira; Monteiro, Thayenne Barrozo Mota; Correa-Oliveira, Rodrigo; Duthie, Malcolm S; Lana, Francisco Carlos Félix

    2016-04-01

    An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I), ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1), and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID). From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

  20. Integrative literature review of the reported uses of serological tests in leprosy management

    Directory of Open Access Journals (Sweden)

    Angélica da Conceição Oliveira Coelho Fabri

    2016-04-01

    Full Text Available Abstract: An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I, ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1, and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID. From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

  1. Serological diagnosis of brucellosis.

    Science.gov (United States)

    Nielsen, K; Yu, W L

    2010-01-01

    To present a review and to describe the most widely used laboratory tests for serology diagnosis of brucellosis along with their pros and cons. Review the recent literature on brucellosis serology diagnostic tests. The choice of the testing strategy depends on the prevailing brucellosis epidemiological situation and the goal of testing. The 'gold standard' for the diagnosis of brucellosis is isolation and identification of the causative bacterium, a member of Brucella sp. Isolation of Brucella sp. requires high security laboratory facilities (biological containment level 3), highly skilled personnel, an extended turnaround time for results and it is considered a hazardous procedure. Hence brucellosis is generally diagnosed by detection of an elevated level of antibody in serum or other body fluid. This is a presumptive diagnosis as other microorganisms and perhaps environmental factors can also cause increased antibody levels. A large number of serological tests for brucellosis have been devised over the 100+ years since its initial isolation, starting with a simple agglutination test and progressing to sophisticated primary binding assays available today. However, no test devised to date is 100% accurate so generally serological diagnosis consists of testing sera by several tests, usually a screening test of high sensitivity, followed by a confirmatory test of high specificity.

  2. Syphilis serology: Seroprevalence in a selected population and considerations on the Euroline WB test

    Directory of Open Access Journals (Sweden)

    Andrea Amodeo

    2010-06-01

    Full Text Available Introduction: The clinical diagnosis of syphilis is always supported by appropriate laboratory tests and the test results are interpreted with reference to the patient’s history. In the diagnosis of syphilis, the use of tests based on antibody search that recognize both treponemal and reaginic antigens increases the diagnostic chances. Our study discusses the various serological and alternative tests currently available along with their limitations, and relates their results to the likely corresponding clinical stage of the disease. Methods: in our laboratory were analyzed 264 sera and 4 liquor (123 Females, 145 Males. 187 patients are subject at low risk for luetic infection, including pregnant woman, patient with organ transplant, outpatients or hospitalized undergoing routine serological, and 81 from patients with confirmed syphilis including 4 pregnant women in antibiotic treatment, patients with suspected disease, HIV positive and patients with autoimmune diseases with Cardiolipin positive. All sera were tested with ELISA Anti-Treponema pallidum Screen (IgG / IgM and in parallel with agglutination tests VDRL and TPHA. On all positive sera was tested Euroline-WB EUROIMMUN and reading done with the program EuroLineScan. Results: by ELISA Anti-Treponema pallidum Screen IgG / IgM 162 sera were negative and 106 sera positive (39.5%, distributed as follows: 45 (42% with a value greater than 200 RU / ml, 43 (41% with a value> 22 RU / ml and 18 (17% with a borderline value between> 16 to <22 RU / ml. The execution of the Blot IgG showed: 18 negative sera, 6 with borderline value with one only band of specific antigens (p15, p45, p47 or p17, while 82, including 4 liquor (neurolue, were certainly positive showing more than one band antibody to the treponemal antigens. Only one patient had in place at the time of screening, an initial infection; in fact, there was a single clear positivity in the IgM protein bands, while 7 sera was uncertain values

  3. Development and evaluation of diagnostic tests for the serological diagnosis of brucellosis in swine

    Directory of Open Access Journals (Sweden)

    Tiziana Di Febo

    2012-06-01

    Full Text Available A competitive enzyme-linked immunosorbent assay (c-ELISA, an indirect ELISA (i-ELISA and a dissociation-enhanced lanthanide fluorescence immunoassay (DELFIA were developed to test for antibodies to Brucella suis in pig and wild boar sera. An anti-Brucella-LPS monoclonal antibody (MAb 4B5A (c-ELISA and DELFIA and an anti-swine IgG monoclonal antibody (MAb 10C2G5 (i-ELISA were used for the three assays. The specificity (Sp and sensitivity (Se of the assays gave the following results: Se and Sp = 100% at a cut-off value of 61.0% (B/B0% for c-ELISA; Sp = 99.1% and Se = 100% at a cut-off value of 21.7% (percentage positivity: PP% for i-ELISA; Sp = 91.0% and Se = 75% at a cut-off value of 37.0% (B/B0% for DELFIA. In addition, the performance of a commercial fluorescence polarisation assay (FPA, standardised for bovine sera, was evaluated in swine sera. The specificity and sensitivity obtained were both 100% at a cut-off value of 99.5 (millipolarisation unit values. These results suggest that the combination of c-ELISA, i-ELISA and FPA can be used to improve the serological diagnosis of swine brucellosis.

  4. Testing for Gluten-Related Disorders in Clinical Practice: The Role of Serology in Managing the Spectrum of Gluten Sensitivity

    Directory of Open Access Journals (Sweden)

    David Armstrong

    2011-01-01

    Full Text Available Immunoglobulin A tissue transglutaminase is the single most efficient serological test for the diagnosis of celiac disease. It is well known that immunoglobulin A tissue transglutaminase levels correlate with the degree of intestinal damage, and that values can fluctuate in patients over time. Serological testing can be used to identify symptomatic individuals that need a confirmatory biopsy, to screen at-risk populations or to monitor diet compliance in patients previously diagnosed with celiac disease. Thus, interpretation of serological testing requires consideration of the full clinical scenario. Antigliadin tests are no longer recommended for the diagnosis of classical celiac disease. However, our understanding of the pathogenesis and spectrum of gluten sensitivity has improved, and gluten-sensitive irritable bowel syndrome patients are increasingly being recognized. Studies are needed to determine the clinical utility of antigliadin serology in the diagnosis of gluten sensitivity.

  5. Evaluation of the diagnostic value of serologic microagglutination testing and a polymerase chain reaction assay for diagnosis of acute leptospirosis in dogs in a referral center.

    Science.gov (United States)

    Fraune, Claudia Kümmerle; Schweighauser, Ariane; Francey, Thierry

    2013-05-15

    To determine the diagnostic value of a serologic microagglutination test (MAT) and a PCR assay on urine and blood for the diagnosis of leptospirosis in dogs with acute kidney injury (AKI). Cross-sectional study. Animals-76 dogs with AKI in a referral hospital (2008 to 2009). Dogs' leptospirosis status was defined with a paired serologic MAT against a panel of 11 Leptospira serovars as leptospirosis-associated (n = 30) or nonleptospirosis-associated AKI (12). In 34 dogs, convalescent serologic testing was not possible, and leptospirosis status was classified as undetermined. The diagnostic value of the MAT single acute or convalescent blood sample was determined in dogs in which leptospirosis status could be classified. The diagnostic value of a commercially available genus-specific PCR assay was evaluated by use of 36 blood samples and 20 urine samples. Serologic acute testing of an acute blood sample had a specificity of 100% (95% CI, 76% to 100%), a sensitivity of 50% (33% to 67%), and an accuracy of 64% (49% to 77%). Serologic testing of a convalescent blood sample had a specificity of 92% (65% to 99%), a sensitivity of 100% (87% to 100%), and an accuracy of 98% (88% to 100%). Results of the Leptospira PCR assay were negative for all samples from dogs for which leptospirosis status could be classified. Serologic MAT results were highly accurate for diagnosis of leptospirosis in dogs, despite a low sensitivity for early diagnosis. In this referral setting of dogs pretreated with antimicrobials, testing of blood and urine samples with a commercially available genus-specific PCR assay did not improve early diagnosis.

  6. Serological biomarker testing helps avoiding unnecessary endoscopies in obese patients before bariatric surgery

    Directory of Open Access Journals (Sweden)

    Jaanus Suumann

    2018-02-01

    Full Text Available Abstract Background To assess the value of serological biomarker testing as a substitute for esophagogastroduodenoscopy (EGDS in pre-operative assessment of patients referred for bariatric surgery. Methods Sixty-five obese patients with a mean age of 43 years (range: 21–65 and a mean body mass index (BMI of 44 (range: 36–59 were studied. The patients were tested with a four-biomarker panel: pepsinogen I and II, gastrin-17 (basal and stimulated, and Helicobacter pylori (HP antibodies (GastroPanel®, Biohit Oyj, Finland. On the basis of the biomarker test, the patients were classified into the HS (healthy stomach group (n = 22 with the normal biomarker profile and the NHS (non-healthy stomach group (n = 43. The classification of patients into HS and NHS was evaluated against the gold standard, i.e. EGDS with biopsies. Results The concordance (Cohen’s kappa between the biomarker test and gastric histology was 0.68; 95% CI 0.504–0.854, with an overall agreement of 84.6% (95% CI 73.9–91.4%. In the NHS group, all 43 patients had biopsy-confirmed chronic gastritis: 39 non-atrophic HP-gastritis, 4 atrophic antrum gastritis (AGA of moderate severity. In the HS group only 6 patients had mild superficial H.pylori negative gastritis. Of the 22 HS subjects with the normal biomarker profile, 20 (31% of all 65 had no complaints either, while the remaining two had reflux symptoms with esophagitis. In the NHS group 10 patients had esophagitis and 8 had also reflux symptoms. Conclusions The normal biomarker profile is an excellent surrogate for healthy stomach, implicating that pre-operative EGDS could have been avoided in 31% of our asymptomatic bariatric surgery patients who had the normal biomarker profile.

  7. Commercial serological antibody detection tests for the diagnosis of pulmonary tuberculosis: a systematic review.

    Directory of Open Access Journals (Sweden)

    Karen R Steingart

    2007-06-01

    Full Text Available BACKGROUND: The global tuberculosis epidemic results in nearly 2 million deaths and 9 million new cases of the disease a year. The vast majority of tuberculosis patients live in developing countries, where the diagnosis of tuberculosis relies on the identification of acid-fast bacilli on unprocessed sputum smears using conventional light microscopy. Microscopy has high specificity in tuberculosis-endemic countries, but modest sensitivity which varies among laboratories (range 20% to 80%. Moreover, the sensitivity is poor for paucibacillary disease (e.g., pediatric and HIV-associated tuberculosis. Thus, the development of rapid and accurate new diagnostic tools is imperative. Immune-based tests are potentially suitable for use in low-income countries as some test formats can be performed at the point of care without laboratory equipment. Currently, dozens of distinct commercial antibody detection tests are sold in developing countries. The question is "do they work?" METHODS AND FINDINGS: We conducted a systematic review to assess the accuracy of commercial antibody detection tests for the diagnosis of pulmonary tuberculosis. Studies from all countries using culture and/or microscopy smear for confirmation of pulmonary tuberculosis were eligible. Studies with fewer than 50 participants (25 patients and 25 control participants were excluded. In a comprehensive search, we identified 68 studies. The results demonstrate that (1 overall, commercial tests vary widely in performance; (2 sensitivity is higher in smear-positive than smear-negative samples; (3 in studies of smear-positive patients, Anda-TB IgG by enzyme-linked immunosorbent assay shows limited sensitivity (range 63% to 85% and inconsistent specificity (range 73% to 100%; (4 specificity is higher in healthy volunteers than in patients in whom tuberculosis disease is initially suspected and subsequently ruled out; and (5 there are insufficient data to determine the accuracy of most

  8. Specific antigen serologic tests in leprosy: implications for epidemiological surveillance of leprosy cases and household contacts.

    Science.gov (United States)

    Carvalho, Ana Paula Mendes; Coelho, Angélica da Conceição Oliveira; Correa-Oliveira, Rodrigo; Lana, Francisco Carlos Félix

    2017-09-01

    There is a lack of straightforward tests for field application and known biomarkers for predicting leprosy progression in infected individuals. The aim was to analyse the response to infection by Mycobacterium leprae based on the reactivity of specific antigens: natural disaccharide linked to human serum albumin via an octyl (NDOHSA), a semisynthetic phenolic glycolipid-I (PGL-I); Leprosy Infectious Disease Research Institute Diagnostic-1 (LID-1) and natural disaccharide octyl - Leprosy Infectious Disease Research Institute Diagnostic-1 (NDOLID). The study population consisted of 130 leprosy cases diagnosed between 2010 and 2015 and 277 household contacts. An enzyme-linked immunosorbent assay (ELISA) was used to analyse the reactivity of antibodies against NDOHSA, LID-1 and NDOLID. The samples and controls were tested in duplicate, and the antibody titer was expressed as an ELISA index. Data collection was made by home visits with application of questionnaire and dermatological evaluation of all household contacts to identify signs and symptoms of leprosy. Significant differences in the median ELISA results were observed among leprosy cases in treatment, leprosy cases that had completed treatment and household contacts. Higher proportions of seropositivity were observed in leprosy cases in treatment. Seropositivity was also higher in multibacillary in relation to paucibacillary, with the difference reaching statistical significance. Lower titers were observed among cases with a longer treatment time or discharge. For household contacts, the differences according to the clinical characteristics of the leprosy index case were less pronounced than expected. Other factors, such as the endemicity of leprosy, exposure outside the residence and genetic characteristics, appeared to have a greater influence on the seropositivity. Serologic tests could be used as auxiliary tools for determining the operational classification, in addition to identifying infected individuals

  9. Development and performance of prototype serologic and molecular tests for hepatitis delta infection.

    Science.gov (United States)

    Coller, Kelly E; Butler, Emily K; Luk, Ka-Cheung; Rodgers, Mary A; Cassidy, Michael; Gersch, Jeffrey; McNamara, Anne L; Kuhns, Mary C; Dawson, George J; Kaptue, Lazare; Bremer, Birgit; Wedemeyer, Heiner; Cloherty, Gavin A

    2018-02-01

    Worldwide, an estimated 5% of hepatitis B virus (HBV) infected people are coinfected with hepatitis delta virus (HDV). HDV infection leads to increased mortality over HBV mono-infection, yet HDV diagnostics are not widely available. Prototype molecular (RNA) and serologic (IgG) assays were developed for high-throughput testing on the Abbott m2000 and ARCHITECT systems, respectively. RNA detection was achieved through amplification of a ribozyme region target, with a limit of detection of 5 IU/ml. The prototype serology assay (IgG) was developed using peptides derived from HDV large antigen (HDAg), and linear epitopes were further identified by peptide scan. Specificity of an HBV negative population was 100% for both assays. A panel of 145 HBsAg positive samples from Cameroon with unknown HDV status was tested using both assays: 16 (11.0%) had detectable HDV RNA, and 23 (15.7%) were sero-positive including the 16 HDV RNA positive samples. Additionally, an archival serial bleed panel from an HDV superinfected chimpanzee was tested with both prototypes; data was consistent with historic testing data using a commercial total anti-Delta test. Overall, the two prototype assays provide sensitive and specific methods for HDV detection using high throughput automated platforms, allowing opportunity for improved diagnosis of HDV infected patients.

  10. VIRAL TESTING USING BIOLOGICAL AND SEROLOGICAL ASSAY FOR MOST IMPORTANT VIRUSES TO PLUM

    Directory of Open Access Journals (Sweden)

    Catita Plopa

    2014-12-01

    Full Text Available Establishing an accurate diagnosis in terms of viral for propagation of fruit tree is very important, it represents the most effective method of protection against viruses. Based on these considerations the primary objective of this study is to detect viruses with the highest incidence in plum by biological and ELISA serological methods, to a number of 85 samples taken from 17 varieties. Serologic testing on DAS-ELISA diagnosed 3 positive samples to Plum pox virus (PPV, 2 positives sample to Prunus necrotic ring spot virus (PNRSV and one positive sample to Prune dwarf virus (PDV. There were not positive samples to Apple chlorotic leaf spot virus (ACLSV. The tests conducted on woody indicator plants by grafting on protect conditions and after 3-24 months assured of diagnosis for PPV, PDV, PNRSV and ACLSV viruses. The biological indicators: ‘GF 305’, ‘Tuleu dulce’ and ‘Vânăt de Italia’, have shown symptoms for PNRSV for two samples.On biological indicator ‘Vânăt de Italia’ and ‘Tuleu dulce’ not appeared symptoms for ‘Centenar’variety tested for PPV, although the symptoms were obvious on ‘GF 305’ indicator, but viral infection was confirmed by ELISA test. Symptoms that indicate the presence of PDV occurred by ‘Vânăt de Italia’ biological indicator.

  11. Standardization of serological tests for detecting anti-Trypanosoma cruzi antibodies in dogs

    Directory of Open Access Journals (Sweden)

    M. A. Lauricella

    1993-09-01

    Full Text Available This paper reports on the standardization of four serological reactions currently used in human serodiagnosis for the detection of anti-Trypanosoma cruzi antibodies in naturally and experimentally infected dogs. Indirect immunofluorescence test (IFAT and hemagglutination test (IHAT were standardized, and complement fixation test (CFT and direct agglutination test (DAT were used for diagnostic confirmation. Four hundred and eighty one mongrel dogs that were studied by xenodiagnosis were used: (1 parasitemic dogs of two localities of endemic area (EA of Santiago del Estero province in Argentina (n = 134; (2 non-parasitemic dogs of the same area (n = 285; (3 dogs experimentally infected with T. cruzi in the patent period (n = 6; (4 non-infected dogs (n = 56 which were born in the city of Buenos Aires (BA, one non-EA for Chagas' disease. For IFAT, parasitemic dogs EA showed 95% of reactive sera. Non parasitemic dogs EA showed 77% of non reactive sera. None sera from BA were reactive for dilutions higher than four. For IHAT, 84% of sera of parasitemic dogs EA showed serological reactivity and among non parasitemic dogs BA, 61% were non reactive, while the remainder showed at most titres of 1/16. The cut-off titres for IFAT and IHAT were 1/16 and 1/32 respectively, and for CFT and DAT 1/1 and 1/128 respectively. Sensitivity for IFAT, IHAT, CF and DAT were 95%, 84%, 97% and 95% respectively.

  12. [The results of serological studies in different foci of tropical and tertiary malaria].

    Science.gov (United States)

    Suleĭmanov, G D; Doan, Kh N; Le, T T; Chan, B; Chan, T U

    1991-01-01

    Attempt was made to determine the value of serologic indices of malaria surveys. Following uniformed methodological and technical approaches 3 foci of P. vivax and 6 foci of P. falciparum malaria were surveyed in different endemic zones of Vietnam and the USSR. It was shown that the most objective criteria for a foci classification is its serologic mean geometric titre. The latter in its turn directly depends of transmission longevity in a foci.

  13. Contribution of a multiplex serological test for the preoperative diagnosis of prosthetic joint infection: a prospective study.

    Science.gov (United States)

    de Seynes, Camille; de Barbeyrac, Bertille; Dutronc, Hervé; Ribes, Clément; Crémer, Paul; Dubois, Véronique; Fabre, Thierry; Dupon, Michel; Dauchy, Frédéric-Antoine

    2018-03-22

    Prosthetic joint infection (PJI) is a severe complication of orthopaedic surgery. Preoperative diagnosis, although sometimes difficult, is key to choose the relevant treatment. We conducted a prospective study aimed at evaluating the diagnostic performance of a multiplex serological test for the pre-operative diagnosis of PJI. Blood samples were collected between 1 July 2016 and 31 July 2017 among patients referred for suspected PJI that occurred at least six weeks prior. Infection diagnosis was confirmed using intraoperative bacteriological cultures during prosthetic exchange. Seventy-one patients were included, with a median age of 73 years (interquartile range [IQR]: 66-81) and 40 (56%) were male. Twenty-six patients had aseptic loosening and 45 patients had PJI. Among the latter, median time since the last surgery was 96 weeks (IQR: 20-324). Intraoperative cultures found Staphylococcus spp, Streptococcus spp or both in 39, 5 and 1 patients, respectively. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 81.8, 95.4, 97.3 and 72.4%, respectively, for all patients and 87.5, 93.5, 94.6 and 85.3%, respectively, for staphylococcal infections. Patients with false negative (FN) results had a significantly lower blood lymphocyte count (p = .045). Multiplex serological test performed well among patients with chronic staphylococcal prosthetic infection. This approach could contribute to PJI diagnosis especially in patients for whom the pre-operative analysis of joint fluid is not informative.

  14. One or two serological assay testing strategy for diagnosis of HBV and HCV infection? The use of predictive modelling.

    Science.gov (United States)

    Parry, John V; Easterbrook, Philippa; Sands, Anita R

    2017-11-01

    Initial serological testing for chronic hepatitis B virus (HBV) and hepatitis C virus (HCV) infection is conducted using either rapid diagnostic tests (RDT) or laboratory-based enzyme immunoassays (EIA)s for detection of hepatitis B surface antigen (HBsAg) or antibodies to HCV (anti-HCV), typically on serum or plasma specimens and, for certain RDTs, capillary whole blood. WHO recommends the use of standardized testing strategies - defined as a sequence of one or more assays to maximize testing accuracy while simplifying the testing process and ideally minimizing cost. Our objective was to examine the diagnostic outcomes of a one- versus two-assay serological testing strategy. These data were used to inform recommendations in the 2017 WHO Guidelines on hepatitis B and C testing. Few published studies have compared diagnostic outcomes for one-assay versus two-assay serological testing strategies for HBsAg and anti-HCV. Therefore, the principles of Bayesian statistics were used to conduct a modelling exercise to examine the outcomes of a one-assay versus two-assay testing strategy when applied to a hypothetical population of 10,000 individuals. The resulting model examined the diagnostic outcomes (true and false positive diagnoses; true and false negative diagnoses; positive and negative predictive values as a function of prevalence; and total tests required) for both one-assay and two-assay testing strategies. The performance characteristics assumed for assays used within the testing strategies were informed by WHO prequalification assessment findings and systematic reviews for diagnostic accuracy studies. Each of the presumptive testing strategies (one-assay or two-assay) was modelled at varying prevalences of HBsAg (10%, 2% and 0.4%) and of anti-HCV (40%, 10%, 2% and 0.4%), aimed at representing the range of testing populations typically encountered in WHO Member States. When the two-assay testing strategy was considered, the model assumed the independence of the

  15. Serological testing versus other strategies for diagnosis of active tuberculosis in India: a cost-effectiveness analysis.

    Directory of Open Access Journals (Sweden)

    David W Dowdy

    2011-08-01

    Full Text Available Undiagnosed and misdiagnosed tuberculosis (TB drives the epidemic in India. Serological (antibody detection TB tests are not recommended by any agency, but widely used in many countries, including the Indian private sector. The cost and impact of using serology compared with other diagnostic techniques is unknown.Taking a patient cohort conservatively equal to the annual number of serological tests done in India (1.5 million adults suspected of having active TB, we used decision analysis to estimate costs and effectiveness of sputum smear microscopy (US$3.62 for two smears, microscopy plus automated liquid culture (mycobacterium growth indicator tube [MGIT], US$20/test, and serological testing (anda-tb ELISA, US$20/test. Data on test accuracy and costs were obtained from published literature. We adopted the perspective of the Indian TB control sector and an analysis frame of 1 year. Our primary outcome was the incremental cost per disability-adjusted life year (DALY averted. We performed one-way sensitivity analysis on all model parameters, with multiway sensitivity analysis on variables to which the model was most sensitive. If used instead of sputum microscopy, serology generated an estimated 14,000 more TB diagnoses, but also 121,000 more false-positive diagnoses, 102,000 fewer DALYs averted, and 32,000 more secondary TB cases than microscopy, at approximately four times the incremental cost (US$47.5 million versus US$11.9 million. When added to high-quality sputum smears, MGIT culture was estimated to avert 130,000 incremental DALYs at an incremental cost of US$213 per DALY averted. Serology was dominated by (i.e., more costly and less effective than MGIT culture and remained less economically favorable than sputum smear or TB culture in one-way and multiway sensitivity analyses.In India, sputum smear microscopy remains the most cost-effective diagnostic test available for active TB; efforts to increase access to quality-assured microscopy

  16. Serological tests fail to discriminate dogs with visceral leishmaniasis that transmit Leishmania infantum to the vector Lutzomyia longipalpis.

    Science.gov (United States)

    Mendonça, Ivete Lopes de; Batista, Joilson Ferreira; Werneck, Guilherme Loureiro; Soares, Maria Regiane Araújo; Costa, Dorcas Lamounier; Costa, Carlos Henrique Nery

    2017-01-01

    The control of reservoirs for Leishmania infantum -induced zoonotic visceral leishmaniasis requires the identification of dogs posing a population risk. Here, we assessed the performance of several assays to identify Lutzomyia longipalpis infectious dogs. We evaluated 99 dogs that were positive for visceral leishmaniasis based on parasite identification. Serological analyses were performed using an enzyme-linked immunosorbent assay, immunofluorescence antibody tests in 1:40 and 1:80 dilutions, rapid dual path platform tests, immunochromatographic assay with a recombinant rK39 antigen, fast agglutination screening tests, and direct agglutination tests. We also performed PCR to analyze peripheral blood and xenodiagnosis. Forty-six dogs infected at least one L. longipalpis specimen. Although the serological test sensitivities were above 85% for detecting L. longipalpis infectious dogs, none showed a satisfactory performance, as both specificity (0.06 to 13%) and the area under the receiver operating characteristic curve (45 to 53%) were low. The PCR results were also weak, with a sensitivity of 30%, specificity of 72%, and an area under the receiver operating characteristic curve of 51%. The infected L. longipalpis proportion was higher among asymptomatic dogs than symptomatic dogs. Among the symptomatic dogs, those with ulceration-free skin diseases were more infectious, with an odds ratio of 9.3 (confidence interval of 1.10 - 428.5). The larger the number of insects fed, the greater the detected infectiousness. Our study supports the imperative to develop novel technologies for identifying the infectious dogs that transmit L. infantum for the benefit of public health.

  17. SEROLOGICAL DIAGNOSIS OF MODERN CHOLERA USING LIPOSOMAL ENTEROTOXIC DIAGNOSTICUM IN COMPLEMENT FIXATION TEST

    Directory of Open Access Journals (Sweden)

    I. V. Savelyeva

    2013-01-01

    Full Text Available Abstract. The possibility of serological diagnosis of cholera using cholera enterotoxic diagnostics kit in complement fixation test to detect anti-enterotoxic antibodies in sera of patients with cholera caused by hybrid variants of the El Tor biovar has been demonstrated. In patients with mild course of cholera anti-enterotoxic antibodies were detected in titres 1:50 and 1:200 in paired sera obtained on the 7th and 14th days of disease, respectively (fourfold titre increase. In patients with the course of medium severity 32-fold titre increase was recorded from the titre 1:100 in serum obtained on the fifth day of disease till the titre 1:3200 — on the twelfth day of disease. Antibodies titers reached 1:1600 and 1:800 were revealed in two medium course patients (adult and infant of 10 months on the sixth day of disease.

  18. How reliable are the sup 14 C-urea breath test and specific serology for the detection of gastric campylobacter

    Energy Technology Data Exchange (ETDEWEB)

    Husebye, E; O' Leary, D; Skar, V; Melby, K [Ullevaal Sykehus, Oslo (Norway)

    1990-01-01

    Detection of gastric campylobacter by the {sup 14}C-urea breath test and serology were correlated to biopsy culture in 25 unselected outpatients referred for gastroscopy. All the 17 culture-positive patients had positive {sup 14}C-urea breath test, and 16 had positive serology. Of eight culture-negative patients, six patients had negative breath test and seven negative serology. A high degree of reproducibility was found when two subsequent breath tests were performed in 11 healthy volunteers. The breath test values obtained at 10 min showed a strong correlation to the accumulated values within 30 min. Breath sampling once, 10 min after intake of 2.5 {mu}Ci {sup 14}C-urea, seems sufficient for the detection of gastric campylobacter. The {sup 14}C-urea breath test correlates well with biopsy culture and provides a sensitive tool for the detection of gastric campylobacter. Serology also corresponds well with biopsy culture and should provide a useful tool for epidemiologic studies. 22 refs., 4 figs., 1 tab.

  19. Accuracy of serological testing for the diagnosis of prevalent neurocysticercosis in outpatients with epilepsy, Eastern Cape Province, South Africa.

    Directory of Open Access Journals (Sweden)

    Humberto Foyaca-Sibat

    2009-12-01

    Full Text Available Few studies have estimated prevalence of neurocysticercosis (NCC among persons with epilepsy in sub-Saharan Africa. While the limitations of serological testing in identification of NCC are well known, the characteristics of persons who are misdiagnosed based on serology have not been explored. The first objective of this pilot study was to estimate the prevalence of NCC in epilepsy outpatients from an area of South Africa endemic for cysticercosis. The second objective was to estimate the accuracy of serological testing in detecting NCC in these outpatients and characterize sources of disagreement between serology and neuroimaging.All out-patients aged 5 or older attending the epilepsy clinic of St. Elizabeth's Hospital in Lusikisiki, Eastern Cape Province, between July 2004 and April 2005 were invited to participate. Epidemiological data were collected by local study staff using a standardized questionnaire. Blood samples were tested by ELISA for antibody and antigen for Taenia solium. Four randomly chosen, consenting participants were transported each week to Mthatha for brain CT scan. The proportion of persons with epilepsy attending St. Elizabeth clinic with CT-confirmed NCC was 37% (95% CI: 27%-48%. Using CT as the gold standard, the sensitivity and specificity of antibody testing for identifying NCC were 54.5% (36.4%-71.9% and 69.2% (52.4%-83.0%, respectively. Sensitivity improved to 78.6% (49.2%-95.3% for those with active lesions. Sensitivity and specificity of antigen testing were considerably poorer. Compared to false negatives, true positives more often had active lesions. False positives were more likely to keep pigs and to have seizure onset within the past year than were true negatives.The prevalence of NCC in South African outpatients with epilepsy is similar to that observed in other countries where cysticercosis is prevalent. Errors in classification of NCC using serology alone may reflect the natural history of NCC.

  20. Strategies for detection of transfusion-transmitted viruses eluding identification by conventional serologic tests. I

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.

    1983-01-01

    The unavailability of serological tests for detection of several not yet characterized infectious agents transmitted by blood transfusion or by blood products prompted the development of alternative tests based on utilization of labeled nucleic acid probes specific for genomes of each of these agents. The prerequisite for the preparation of such probes is the demonstration in human plasma of nucleic acid sequences distinct from those present in host DNA or in genes of already characterized viruses occurring in plasma of infected individuals. To accomplish this, ultrasensitive tests for nucleic acids not dependent on their base sequence are needed. The authors describe a radioimmunoassay (RIA) for picogram quantities of DNA. Plasma (serum) specimens are treated with proteinase K in the presence of sodium dodecyl sulfate and extracted with phenol. Nucleic acids are precipitated with ethanol in the presence of dextran (mol.wt. approx. 5X10 5 ) as carrier. Subsequently, DNA from the redissolved samples is adsorbed onto polylysine-coated wells of microtiter plates and detected by a double-antibody RIA using anti-DNA autoantibodies from NZB/NZW mice and 125 I-labelled antibodies to mouse immunoglobulins. DNA which did not hybridize with human DNA was detected by this method in sera containing hepatitis B virus used as a model system. (Auth.)

  1. Evaluation of In-House and Commercial Serological Tests for Diagnosis of Human Tularemia

    Science.gov (United States)

    Yanes, Hadjila; Hennebique, Aurélie; Pelloux, Isabelle; Boisset, Sandrine; Bicout, Dominique J.; Caspar, Yvan

    2017-01-01

    ABSTRACT Tularemia is a zoonosis caused by the bacterium Francisella tularensis. Its specific diagnosis remains based on serological methods, while F. tularensis is rarely detected in clinical samples by culture or PCR. The aim of the present study was to evaluate the performance of the Serion enzyme-linked immunosorbent assay (ELISA) classic Francisella tularensis IgG and IgM tests (Virion/Serion GmbH Institute, Würzburg, Germany) and the VIRapid tularemia immunochromatographic test (ICT) (Vircell, Granada, Spain) compared to that of the in-house microagglutination test (MAT) and indirect immunofluorescence assay (IFA) currently used at the French National Reference Center for Francisella. We evaluated 256 consecutive sera from 208 patients, including 51 confirmed and 23 probable tularemia cases, and 134 control patients not infected with F. tularensis. The IFA tests displayed 72.5% sensitivity for IgM (cutoff titer ≥80) and 74.5% for IgG (cutoff titer ≥160), and 99.3% specificity for both IgM and IgG. Using cutoffs advocated by the manufacturer, the Serion ELISAs displayed 88.2% sensitivity for IgM and 86.3% for IgG antibodies; specificity was 94.8% for IgM and 95.5% for IgG. Compared to MAT and IFA tests, the Serion ELISAs allowed earlier detection of specific antibodies (1 to 2 weeks versus 2 to 3 weeks after the onset of symptoms). The ICT sensitivity and specificity were 90% and 83.6%, respectively, when considering the cutoff advocated by the manufacturer. In conclusion, the Serion ELISAs are useful as screening tests for tularemia diagnosis, but additional confirmatory tests (such as MAT and IFA) are needed, especially in areas of low endemicity. PMID:29118164

  2. Application of Mycobacterium Leprae-specific cellular and serological tests for the differential diagnosis of leprosy from confounding dermatoses.

    Science.gov (United States)

    Freitas, Aline Araújo; Hungria, Emerith Mayra; Costa, Maurício Barcelos; Sousa, Ana Lúcia Osório Maroccolo; Castilho, Mirian Lane Oliveira; Gonçalves, Heitor Sá; Pontes, Maria Araci Andrade; Duthie, Malcolm S; Stefani, Mariane Martins Araújo

    2016-10-01

    Mycobacterium leprae-specific serological and cell-mediated-immunity/CMI test were evaluated for the differential diagnosis of multibacillary/MB, and paucibacillary/PB leprosy from other dermatoses. Whole-blood assay/WBA/IFNγ stimulated with LID-1 antigen and ELISA tests for IgG to LID-1 and IgM to PGL-I were performed. WBA/LID-1/IFNγ production was observed in 72% PB, 11% MB leprosy, 38% dermatoses, 40% healthy endemic controls/EC. The receiver operating curve/ROC for WBA/LID-1 in PB versus other dermatoses showed 72.5% sensitivity, 61.5% specificity and an area-under-the-curve/AUC=0.75; 74% positive predictive value/PPV, 59% negative predictive value/NPV. Anti PGL-I serology was positive in 67% MB, 8% PB leprosy, 6% of other dermatoses; its sensitivity for MB=66%, specificity=93%, AUC=0.89; PPV=91%, NPV=72%. Anti-LID-1 serology was positive in 87% MB, 7% PB leprosy, all other participants were seronegative; 87.5% sensitivity for MB, 100% specificity, AUC=0.97; PPV=100%, NPV=88%. In highly endemic areas anti-LID-1/PGL-I serology and WBA/LID-1-represent useful tools for the differential diagnosis of leprosy from other confounding dermatoses. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. 21 CFR 866.3390 - Neisseria spp. direct serological test reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3390... Neisseria spp. directly from clinical specimens. The identification aids in the diagnosis of disease caused...

  4. Comparison of the serological tests ICT and ELISA for the diagnosis of alveolar echinococcosis in France.

    Science.gov (United States)

    Knapp, Jenny; Sako, Yasuhito; Grenouillet, Frédéric; Bresson-Hadni, Solange; Richou, Carine; Gbaguidi-Haore, Houssein; Ito, Akira; Millon, Laurence

    2014-01-01

    Serological diagnosis of alveolar echinococcosis (AE) is a key element for efficient patient treatment management. A rapid immunochromatography test kit (ICT) using the recombinant Em18 antigen (rEm18) was recently developed. The aim of our study was to assess this test on a panel of sera from French patients with alveolar echinococcosis and control patients. In a blind test, a total of 112 serum samples were tested including samples of AE (n = 30), cystic echinococcosis [CE] (n = 15), and polycystic echinococcosis [PE] (n = 1). For the comparison, 66 sera from patients with hepatocarcinoma, fascioliasis, toxocariasis, Caroli's disease, or autoimmune chronic active hepatitis were used. The diagnostic test sets we used were the rEm18-ICT and two validated ELISAs with rEm18 and Em2-Em18 antigens, respectively. For the ICT, 27/30 sera from AE patients, 4/15 sera from CE patients and the PE patient serum were positive. One serum from the control panel (toxocariasis) was positive for the ICT. The rEm18-ICT sensitivity (90.0%) and specificity (92.7%) for detection of Em18-specific antibodies confirmed it as a relevant tool for AE diagnosis. The rEm18-ELISA had a sensitivity of 86.7% and specificity of 91.5%, and the Em2-Em18-ELISA had a sensitivity of 96.7% and specificity of 87.8%. However, when AE patient sera are recorded as weak in intensity with the ICT, we recommend a double reading and use of a reference sample if the ICT is used for patient follow-up. © J. Knapp et al., published by EDP Sciences, 2014.

  5. Climax granite test results

    Energy Technology Data Exchange (ETDEWEB)

    Ramspott, L.D.

    1980-01-15

    The Lawrence Livermore Laboratory (LLL), as part of the Nevada Nuclear Waste Storage Investigations (NNWSI) program, is carrying out in situ rock mechanics testing in the Climax granitic stock at the Nevada Test Site (NTS). This summary addresses only those field data taken to date that address thermomechanical modeling for a hard-rock repository. The results to be discussed include thermal measurements in a heater test that was conducted from October 1977 through July 1978, and stress and displacement measurements made during and after excavation of the canister storage drift for the Spent Fuel Test (SFT) in the Climax granite. Associated laboratory and field measurements are summarized. The rock temperature for a given applied heat load at a point in time and space can be adequately modeled with simple analytic calculations involving superposition and integration of numerous point source solutions. The input, for locations beyond about a meter from the source, can be a constant thermal conductivity and diffusivity. The value of thermal conductivity required to match the field data is as much as 25% different from laboratory-measured values. Therefore, unless we come to understand the mechanisms for this difference, a simple in situ test will be required to obtain a value for final repository design. Some sensitivity calculations have shown that the temperature field is about ten times more sensitive to conductivity than to diffusivity under the test conditions. The orthogonal array was designed to detect anisotropy. After considering all error sources, anisotropic efforts in the thermal field were less than 5 to 10%.

  6. Serological IgG Testing to Diagnose Alimentary Induced Diseases and Monitoring Efficacy of an Individual Defined Diet in Dogs

    OpenAIRE

    Anne-Margré C. Vink

    2014-01-01

    Background. Food-related allergies and intolerances are frequently occurring in dogs. Diagnosis and monitoring according ‘Golden Standard’ of elimination efficiency is, however, time consuming, expensive, and requires expert clinical setting. In order to facilitate rapid and robust, quantitative testing of intolerance, and determining the individual offending foods, a serological test is implicated for Alimentary Induced Diseases and manifestations. Method. As we developed Medisynx IgG Human ...

  7. Detection of Toxoplasma gondii DNA in horse meat from supermarkets in France and performance evaluation of two serological tests

    OpenAIRE

    Aroussi Abdelkrim; Vignoles Philippe; Dalmay François; Wimel Laurence; Dardé Marie-Laure; Mercier Aurélien; Ajzenberg Daniel

    2015-01-01

    In France, some cases of severe toxoplasmosis have been linked to the consumption of horse meat that had been imported from the American continent where atypical strains of Toxoplasma gondii are more common than in Europe. Many seroprevalence studies are presented in the literature but risk assessment of T. gondii infection after horse meat consumption is not possible in the absence of validated serological tests and the unknown correlation between detection of antibodies against T. gondii an...

  8. Course of Chronic Trypanosoma cruzi Infection after Treatment Based on Parasitological and Serological Tests: A Systematic Review of Follow-Up Studies.

    Directory of Open Access Journals (Sweden)

    Yanina Sguassero

    and 48 cohort studies were included. The smoothed curves for positive xenodiagnosis and positive polymerase chain reaction (PCR were characterized by a sharp decrease at twelve month posttreatment. Afterwards, they reached 10-20% and 40% for xenodiagnosis and PCR, respectively. The smoothed curves for negative conventional serological tests increased up to 10% after 48 months of treatment. In the long-term, the rate of negativization was between 20% and 45%. The main sources of bias identified across cohort studies were the lack of control for confounding and attrition bias. In general, RCTs were judged as low risk of bias in all domains. The level of heterogeneity across included studies was moderate to high. Additional analysis were incomplete because of the limited availability of data. In this regard, the country of origin of study participants might affect the results of parasitological and molecular tests, while the level of risk of bias might affect serological outcomes. Subgroup analysis suggested that seronegativization occurs earlier in children compared to adults.We acknowledge that there is a dynamic pattern of response based on parasitological, molecular and serological tests in subjects chronically infected with T. cruzi after treatment. Our findings suggest a trypanocidal effect in the long-term follow-up. Further research is needed to explore potential sources of heterogeneity and to conduct reliable subgroup analysis.

  9. Commercial serological tests for the diagnosis of active pulmonary and extrapulmonary tuberculosis: an updated systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Karen R Steingart

    2011-08-01

    Full Text Available BACKGROUND: Serological (antibody detection tests for tuberculosis (TB are widely used in developing countries. As part of a World Health Organization policy process, we performed an updated systematic review to assess the diagnostic accuracy of commercial serological tests for pulmonary and extrapulmonary TB with a focus on the relevance of these tests in low- and middle-income countries. METHODS AND FINDINGS: We used methods recommended by the Cochrane Collaboration and GRADE approach for rating quality of evidence. In a previous review, we searched multiple databases for papers published from 1 January 1990 to 30 May 2006, and in this update, we add additional papers published from that period until 29 June 2010. We prespecified subgroups to address heterogeneity and summarized test performance using bivariate random effects meta-analysis. For pulmonary TB, we included 67 studies (48% from low- and middle-income countries with 5,147 participants. For all tests, estimates were variable for sensitivity (0% to 100% and specificity (31% to 100%. For anda-TB IgG, the only test with enough studies for meta-analysis, pooled sensitivity was 76% (95% CI 63%-87% in smear-positive (seven studies and 59% (95% CI 10%-96% in smear-negative (four studies patients; pooled specificities were 92% (95% CI 74%-98% and 91% (95% CI 79%-96%, respectively. Compared with ELISA (pooled sensitivity 60% [95% CI 6%-65%]; pooled specificity 98% [95% CI 96%-99%], immunochromatographic tests yielded lower pooled sensitivity (53%, 95% CI 42%-64% and comparable pooled specificity (98%, 95% CI 94%-99%. For extrapulmonary TB, we included 25 studies (40% from low- and middle-income countries with 1,809 participants. For all tests, estimates were variable for sensitivity (0% to 100% and specificity (59% to 100%. Overall, quality of evidence was graded very low for studies of pulmonary and extrapulmonary TB. CONCLUSIONS: Despite expansion of the literature since 2006, commercial

  10. Commercial Serological Tests for the Diagnosis of Active Pulmonary and Extrapulmonary Tuberculosis: An Updated Systematic Review and Meta-Analysis

    Science.gov (United States)

    Steingart, Karen R.; Flores, Laura L.; Dendukuri, Nandini; Schiller, Ian; Laal, Suman; Ramsay, Andrew; Hopewell, Philip C.; Pai, Madhukar

    2011-01-01

    Background Serological (antibody detection) tests for tuberculosis (TB) are widely used in developing countries. As part of a World Health Organization policy process, we performed an updated systematic review to assess the diagnostic accuracy of commercial serological tests for pulmonary and extrapulmonary TB with a focus on the relevance of these tests in low- and middle-income countries. Methods and Findings We used methods recommended by the Cochrane Collaboration and GRADE approach for rating quality of evidence. In a previous review, we searched multiple databases for papers published from 1 January 1990 to 30 May 2006, and in this update, we add additional papers published from that period until 29 June 2010. We prespecified subgroups to address heterogeneity and summarized test performance using bivariate random effects meta-analysis. For pulmonary TB, we included 67 studies (48% from low- and middle-income countries) with 5,147 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (31% to 100%). For anda-TB IgG, the only test with enough studies for meta-analysis, pooled sensitivity was 76% (95% CI 63%–87%) in smear-positive (seven studies) and 59% (95% CI 10%–96%) in smear-negative (four studies) patients; pooled specificities were 92% (95% CI 74%–98%) and 91% (95% CI 79%–96%), respectively. Compared with ELISA (pooled sensitivity 60% [95% CI 6%–65%]; pooled specificity 98% [95% CI 96%–99%]), immunochromatographic tests yielded lower pooled sensitivity (53%, 95% CI 42%–64%) and comparable pooled specificity (98%, 95% CI 94%–99%). For extrapulmonary TB, we included 25 studies (40% from low- and middle-income countries) with 1,809 participants. For all tests, estimates were variable for sensitivity (0% to 100%) and specificity (59% to 100%). Overall, quality of evidence was graded very low for studies of pulmonary and extrapulmonary TB. Conclusions Despite expansion of the literature since 2006

  11. Comparison of a Recombinant-antigen Enzyme Immunoassay with Treponema pallidum Hemagglutination Test for Serological Confirmation of Syphilis

    Directory of Open Access Journals (Sweden)

    Rodríguez Islay

    2002-01-01

    Full Text Available A recombinant-antigen enzyme immunoassay (EIA, BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38, secondary (n = 10, early latent (n = 28 and congenital syphilis (n = 2, patients with leptospirosis ( n= 8, infectious mononucleosis (n = 7, hepatitis (n = 9, diabetes mellitus (n = 11, rheumatoid arthritis (n = 13, leprosy (n = 11, tuberculosis (n = 9, HIV/Aids ( n= 12, systemic lupus erythematosus (n = 4, rheumatic fever (n = 3, old-persons (n = 9, pregnant women (n = 29 and blood donors (n = 164. The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.

  12. Seroprevalence and epidemiological correlates of Toxoplasma gondii infections among patients referred for hospital-based serological testing in Doha, Qatar

    Directory of Open Access Journals (Sweden)

    Al-Molawi Naema

    2008-10-01

    Full Text Available Abstract Background The city of Doha in Qatar has a high density of feral cats and there is a high risk of toxoplasmosis for the resident human population. No data currently exist for the prevalence of infection with Toxoplasma gondii in the city. Methods We analysed the serological response to Toxoplasma gondii of 1625 subjects referred for routine hospital based serological tests in Doha, Qatar. Prevalence of current/recent infection was assessed through an enzyme-linked immunosorbent assay (ELISA for the presence of specific anti-T. gondii IgM antibodies, and previous history of infection through IgG. Results Overall prevalence of IgG responses was 29.8% and this did not differ between the sexes nor between the three years of the study although there was a marked age effect. Among children less than 1 year old prevalence was 22.9%, but then dropped to in utero from immune mothers. Prevalence then increased steadily to peak at 41.2% among the oldest age class (>45 years. The prevalence of IgG antibody also varied significantly with region of origin, with higher rates for subjects from Africa, followed by those from the Eastern Mediterranean or Asia and lowest rates for subjects from the Arabian Peninsula. No IgM antibodies were detected in any subjects younger than 19 years, but prevalence increased to plateau at 7 – 9% in subjects aged over 20 years, and also varied with region of origin. In this case prevalence was highest among subjects from the Arabian Peninsula and least among those from Asia. Prevalence of IgM was higher among male subjects but did not vary between the three years of the study. Conclusion Although these data are based on a selected subset of the population, they nevertheless provide the first evidence that toxoplasmosis is endemic in Qatar in the human population, and that both age and region of origin play a role in the epidemiology of the infection. Concerns relating to the role of high density of feral cats in

  13. Evaluation of diagnostic serological results in cases of suspected primary syphilis infection.

    Science.gov (United States)

    Gratzer, Beau; Pohl, Daniel; Hotton, Anna L

    2014-05-01

    Reverse sequence screening for syphilis, in which an automatable treponemal assay (enzyme immunoassay [EIA]/chemiluminescence assay [CIA]) is performed first and followed by a nontreponemal test for reactive specimens, has been used increasingly in the United States. The EIA is objective, efficient, and believed to be more sensitive than the rapid plasma reagin (RPR) because treponemal antibodies appear before nontreponemal antibodies. We sought to compare the sensitivity of a commonly used EIA, the Trep-Sure EIA (TS-EIA), to the RPR in cases of suspected primary syphilis infection in our clinic. A retrospective medical record review of patients with sexually transmitted infection clinic visits from January 2009 to December 2011 was conducted, and 52 patients met the following inclusion criteria: suspected primary syphilis symptoms, at least 1 positive syphilis test result at visit, and no history of syphilis. Sensitivity analyses compared the TS-EIA and RPR, using the reference standard of concordantly positive/reactive TS-EIA/RPR or positive fluorescent treponemal antibody absorption test (FTA-ABS) result. We considered equivocal TS-EIA results to be positive for sensitivity calculations because such results typically reflex to additional testing and therefore may still result in identifying new infections. Twenty-eight (53.8%) of the 52 patients had a positive or equivocal TS-EIA. Twenty-five (89.3%) of those were RPR reactive; the remaining 3 (10.7%) were RPR nonreactive, FTA-ABS positive. Forty patients (76.9%) had a positive RPR, including 15 patients (37.5%) with negative TS-EIA results; all 15 were FTA-ABS positive. Nine additional patients were TS-EIA negative and RPR nonreactive but had a positive FTA-ABS result. The RPR was significantly more sensitive than the EIA (76.9% vs. 53.8%, P = 0.005). Trep-Sure EIA positivity was also significantly associated with higher median RPR titer (P = 0.011). Use of the TS-EIA may result in underdetection of primary

  14. Performance of TB immunodiagnostic tests in Eurasian badgers (Meles meles of different ages and the influence of duration of infection on serological sensitivity

    Directory of Open Access Journals (Sweden)

    Sayers Robin

    2009-11-01

    Full Text Available Abstract Background In parts of Great Britain and Ireland, Eurasian badgers (Meles meles constitute a reservoir of Mycobacterium bovis infection and a potential source of infection for cattle. In vitro diagnostic tests for live badgers are an important component of strategies to control TB in this species. Immunological tests have been developed for badgers, although little is known about the influence of the age of the animal on test performance. To address this, we evaluated the performance of three immunological tests for badgers with respect to the age of the animal: the Brock Test and BrockTB STAT-PAK® serological tests and the recently developed interferon-gamma enzyme immunoassay (IFNγ EIA. Data published elsewhere suggested that seropositivity was associated with more progressive forms of TB in the badger. To gain further evidence for this, we used longitudinal data from a well-studied population of badgers to test for an association between the sensitivity of the Brock Test and the duration of TB infection. Results Sensitivity of the two serological tests was approximately 54% for both cubs and adults. Sensitivity of the IFNγ EIA was lower in cubs (57% compared with adults (85% when a common cut-off value was used to define test positivity. Taking data from the cubs alone, the IFNγ EIA cut-off value could be adjusted to increase the sensitivity to 71% with no loss in specificity. As a general observation, specificity of all tests was higher in cubs, although only significantly so in the case of the Brock Test. Using logistic regression analysis to adjust for age, sensitivity of the Brock Test was significantly lower at first culture positive event (58%, but increased to >80% as infection progressed. Conclusion These data suggest that serodiagnosis could be a valuable tool for detecting a higher proportion of badgers with the greatest probability of transmitting infection. The age category of the badger appeared to exert little

  15. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  16. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  17. [Analysis on the results of etiology and serology of plague in Qinghai province from 2001 to 2010].

    Science.gov (United States)

    Yang, Yonghai; Wang, Mei; Zhao, Xiaolong; Zhao, Zhongzhi; Zhang, Aiping; Wei, Rongjie; Wei, Baiqing; Wang, Zuyun

    2014-02-01

    To analyze the results of etiology and serology of plague among human and infected animals in Qinghai province from 2001 to 2010. Thirty-seven cases of human infected with plague, 53 541 different animal samples, 5 685 sets of vector insects flea and 49 039 different animal serum samples were obtained between 2001 and 2010. A total of 7 811 samples of serum from healthy farmers and herdsmen in 14 counties in Qinghai from 2005 to 2007 were collected. Yersinia pestis (Y. pestis) were detected in visceral and secretions from human, infected animals and vector insects, respectively. Plague antigen was detected by reverse indirect hemagglutination assay (RIHA) in those samples. Indirect hemagglutination assay (IHA) was used to test plague FI antibody in serum of human and infected animals. 37 human plague cases were confirmed, 21 strains of plague Y. pestis were isolated from human cases and 14 positive were detected out. 133 of 7 811 samples of human serum were IHA positive, with the positive rate at 1.7%. A total of 146 strains of plague were isolated from infected animals and vector insects, 99 out of which were from infected animals, with a ratio of Marmota himalayan at 72.7% (72/99) and the other 47 were from vector insects, with a ratio of callopsylla solaris at 68.1% (32/47). The number of IHA and PIHA positive were 300 and 10, respectively. A total of 3 animals and 3 insects species were identified as new epidemic hosts for plague. The natural plague focus of Microtus fuscus was discovered and confirmed and coexisted with natural focus of Marmota himalayan in Chengduo county, Yushu prefecture. The epidemic situation of plague is distributed mainly in Haixi, Yushu and Hainan prefectures. From 2001 to 2010, animal infected with plague was detected in successive years and human plague was very common in Qinghai. New infected animals and vector insects species and new epidemic areas were confirmed, hence the trend of plague prevalence for humans and animals is very

  18. Sensitivity and specificity of various serologic tests for detection of Toxoplasma gondii infection in naturally infected sows

    DEFF Research Database (Denmark)

    Dubey, J.P.; Thulliez, P.; Weigel, R.M.

    1995-01-01

    antibodies by use of the modified agglutination test (MAT), latex agglutination test (LAT), indirect hemagglutination test (IHAT), and ELISA. Toxoplasma gondii was isolated from 170 hearts of 1,000 sows by bioassays in mice and cats. The percentage of samples diagnosed as positive for each of the serologic......, 29.4 and 98.3% for IHAT, 45.9 and 96.9% for LAT, and 72.9 and 85.9% for ELISA. The dye test was run at 1:20 dilution on only 893 sera because of bacterial contamination and presence of anticomplement substances. Dye test antibodies were found in 17.8% of the sera, and sensitivity and specificity were...

  19. Impact of a confirmatory RhD test on the correct serologic typing of blood donors

    Directory of Open Access Journals (Sweden)

    Luciana Cayres Schmidt

    2015-10-01

    Full Text Available BACKGROUND: The RHD gene is highly polymorphic, which results in a large number of RhD variant phenotypes. Discrepancies in RhD typing are still a problem in blood banks and increase the risk of alloimmunization. In this study, the RhD typing strategy at a blood bank in Brazil was evaluated.METHODS: One-hundred and fifty-two samples typed as RhD negative and C or E positive by routine tests (automated system and indirect antiglobulin test using the tube technique were reevaluated for RhD status by three methods. The method with the best performance was implemented and evaluated for a period of one year (n = 4897 samples. Samples that were D positive exclusively in the confirmatory test were submitted to molecular analysis.RESULTS: The gel test for indirect antiglobulin testing with anti-D immunoglobulin G (clone ESD1 presented the best results. Seventy samples (1.43% previously typed as RhD negative showed reactivity in the gel test for indirect antiglobulin testing and were reclassified as D positive. D variants that may cause alloimmunization, such as weak D type 2 and partial DVI, were detected.CONCLUSION: The confirmatory RhD test using the gel test for indirect antiglobulin testing represents a breakthrough in transfusion safety in this blood center. Our results emphasize the importance of assessing the blood group typing strategy in blood banks.

  20. Comparison of two automated instruments for Epstein-Barr virus serology in a large adult hospital and implementation of an Epstein-Barr virus nuclear antigen-based testing algorithm.

    Science.gov (United States)

    Al Sidairi, Hilal; Binkhamis, Khalifa; Jackson, Colleen; Roberts, Catherine; Heinstein, Charles; MacDonald, Jimmy; Needle, Robert; Hatchette, Todd F; LeBlanc, Jason J

    2017-11-01

    Serology remains the mainstay for diagnosis of Epstein-Barr virus (EBV) infection. This study compared two automated platforms (BioPlex 2200 and Architect i2000SR) to test three EBV serological markers: viral capsid antigen (VCA) immunoglobulins of class M (IgM), VCA immunoglobulins of class G (IgG) and EBV nuclear antigen-1 (EBNA-1) IgG. Using sera from 65 patients at various stages of EBV disease, BioPlex demonstrated near-perfect agreement for all EBV markers compared to a consensus reference. The agreement for Architect was near-perfect for VCA IgG and EBNA-1 IgG, and substantial for VCA IgM despite five equivocal results. Since the majority of testing in our hospital was from adults with EBNA-1 IgG positive results, post-implementation analysis of an EBNA-based algorithm showed advantages over parallel testing of the three serologic markers. This small verification demonstrated that both automated systems for EBV serology had good performance for all EBV markers, and an EBNA-based testing algorithm is ideal for an adult hospital.

  1. Detection of Toxoplasma gondii DNA in horse meat from supermarkets in France and performance evaluation of two serological tests

    Directory of Open Access Journals (Sweden)

    Aroussi Abdelkrim

    2015-01-01

    Full Text Available In France, some cases of severe toxoplasmosis have been linked to the consumption of horse meat that had been imported from the American continent where atypical strains of Toxoplasma gondii are more common than in Europe. Many seroprevalence studies are presented in the literature but risk assessment of T. gondii infection after horse meat consumption is not possible in the absence of validated serological tests and the unknown correlation between detection of antibodies against T. gondii and presence of tissue cysts. We performed magnetic-capture polymerase chain reaction (MC-PCR to detect T. gondii DNA in 231 horse meat samples purchased in supermarkets in France and evaluated the performance and level of agreement of the modified agglutination test (MAT and enzyme-linked immunosorbent assay (ELISA in the meat juices. The serological tests lacked sensitivity, specificity, and agreement between them, and there was no correlation with the presence of T. gondii DNA in horse meat, raising concerns about the reliability of T. gondii seroprevalence data in horses from the literature. T. gondii DNA was detected in 43% of horse meat samples but the absence of strain isolation in mice following inoculation of more than 100 horse meat samples suggests a low distribution of cysts in skeletal muscles and a low risk of T. gondii infection associated with horse meat consumption. However, to avoid any risk of toxoplasmosis, thorough cooking of horse meat is recommended.

  2. Detection of Toxoplasma gondii DNA in horse meat from supermarkets in France and performance evaluation of two serological tests.

    Science.gov (United States)

    Aroussi, Abdelkrim; Vignoles, Philippe; Dalmay, François; Wimel, Laurence; Dardé, Marie-Laure; Mercier, Aurélien; Ajzenberg, Daniel

    2015-01-01

    In France, some cases of severe toxoplasmosis have been linked to the consumption of horse meat that had been imported from the American continent where atypical strains of Toxoplasma gondii are more common than in Europe. Many seroprevalence studies are presented in the literature but risk assessment of T. gondii infection after horse meat consumption is not possible in the absence of validated serological tests and the unknown correlation between detection of antibodies against T. gondii and presence of tissue cysts. We performed magnetic-capture polymerase chain reaction (MC-PCR) to detect T. gondii DNA in 231 horse meat samples purchased in supermarkets in France and evaluated the performance and level of agreement of the modified agglutination test (MAT) and enzyme-linked immunosorbent assay (ELISA) in the meat juices. The serological tests lacked sensitivity, specificity, and agreement between them, and there was no correlation with the presence of T. gondii DNA in horse meat, raising concerns about the reliability of T. gondii seroprevalence data in horses from the literature. T. gondii DNA was detected in 43% of horse meat samples but the absence of strain isolation in mice following inoculation of more than 100 horse meat samples suggests a low distribution of cysts in skeletal muscles and a low risk of T. gondii infection associated with horse meat consumption. However, to avoid any risk of toxoplasmosis, thorough cooking of horse meat is recommended. © A. Aroussi et al., published by EDP Sciences, 2015.

  3. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Science.gov (United States)

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; ppoor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  4. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Directory of Open Access Journals (Sweden)

    Susheela D Biranjia-Hurdoyal

    Full Text Available The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit.Stool and blood samples were collected from 162 apparently healthy participants (control and 60 Type 2 diabetes mellitus (T2DM patients.The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%, followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%. The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value.The performances of the detection kits were affected by various factors which should be taken into consideration.

  5. CCTF CORE I test results

    International Nuclear Information System (INIS)

    Murao, Yoshio; Sudoh, Takashi; Akimoto, Hajime; Iguchi, Tadashi; Sugimoto, Jun; Fujiki, Kazuo; Hirano, Kenmei

    1982-07-01

    This report presents the results of the following CCTF CORE I tests conducted in FY. 1980. (1) Multi-dimensional effect test, (2) Evaluation model test, (3) FLECHT coupling test. On the first test, one-dimensional treatment of the core thermohydrodynamics was discussed. On the second and third tests, the test results were compared with the results calculated by the evaluation model codes and the results of the corresponding FLECHT-SET test (Run 2714B), respectively. The work was performed under contracts with the Atomic Energy Bureau of Science and Technology Agency of Japan. (author)

  6. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital

    Directory of Open Access Journals (Sweden)

    Aseem K Tiwari

    2015-01-01

    Full Text Available Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study of <10% co-efficient of variation. There was no cross-reactivity with other viral and auto-immune antibodies. No interference was observed from endogenous interfering substances like free hemoglobin or fats. Conclusions: Performance of the VITROS ® syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  7. A comparative study of an elisa test and an indirect immunofluorescence test for serological diagnosis of Babesia bovis infection

    International Nuclear Information System (INIS)

    Martins, J.R.; Cheong, F.H.; Correa, B.L.; Radley, D.E.; Cereser, V.H.

    1998-01-01

    Detection of antibodies to Babesia bovis in cattle is essential for the understanding of the epidemiology of babesiosis and this study was concerned with comparing the indirect fluorescent antibody with the ELISA. Both assays gave rise to 100% sensitivity whilst the ELISA was shown to be marginally more specific at 98%. The ease of use and low cost of the ELISA would make it the more obvious choice in conducting future serological surveys for this parasite. (author)

  8. Comparison of serological and milk tests for bovine brucellosis using a Monte Carlo simulation model

    Directory of Open Access Journals (Sweden)

    V. Caporale

    2004-01-01

    Full Text Available European Union (EU Directive 97/12/EC allows the trade of cattle within the EU of animals originating from an 'officially brucellosis-free herd'. To qualify for this status, a number of different programmes must be implemented. Each EU Member Country is free to decide which procedure to use to qualify herds. The authors conducted a study to compare the merits and costs of testing programmes given in the Directive and of some alternative testing strategies. The effectiveness of testing programmes was evaluated by a Monte Carlo simulation model. Programmes listed in the Directive do not appear to have identical sensitivity and specificity. Simulations of the programmes showed that milk testing may be more effective and efficient than blood testing to identify infected herds. Results indicated that it could be advisable that legislation, rather than defining very detailed procedures both for laboratory tests and testing programmes, should establish minimal requirements in terms of efficacy of testing procedures (i.e. the probability of detecting an infected herd.

  9. 21 CFR 866.3120 - Chlamydia serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3120 Chlamydia... and antisera used in serological tests to identify antibodies to chlamydia in serum. Additionally...

  10. 21 CFR 866.3490 - Rhinovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3490 Rhinovirus... and antisera used in serological tests to identify antibodies to rhinovirus in serum. The...

  11. Two years of surveillance of influenza a virus infection in a swine herd. Results of virological, serological and pathological studies.

    Science.gov (United States)

    Cappuccio, Javier; Dibarbora, Marina; Lozada, Inés; Quiroga, Alejandra; Olivera, Valeria; Dángelo, Marta; Pérez, Estefanía; Barrales, Hernán; Perfumo, Carlos; Pereda, Ariel; Pérez, Daniel R

    2017-02-01

    Swine farms provide a dynamic environment for the evolution of influenza A viruses (IAVs). The present report shows the results of a surveillance effort of IAV infection in one commercial swine farm in Argentina. Two cross-sectional serological and virological studies (n=480) were carried out in 2011 and 2012. Virus shedding was detected in nasal samples from pigs from ages 7, 21 and 42-days old. More than 90% of sows and gilts but less than 40% of 21-days old piglets had antibodies against IAV. In addition, IAV was detected in 8/17 nasal swabs and 10/15 lung samples taken from necropsied pigs. A subset of these samples was further processed for virus isolation resulting in 6 viruses of the H1N2 subtype (δ2 cluster). Pathological studies revealed an association between suppurative bronchopneumonia and necrotizing bronchiolitis with IAV positive samples. Statistical analyses showed that the degree of lesions in bronchi, bronchiole, and alveoli was higher in lungs positive to IAV. The results of this study depict the relevance of continuing long-term active surveillance of IAV in swine populations to establish IAV evolution relevant to swine and humans. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Serologic test systems development. Progress report, July 1, 1976--September 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, G.C.; Clinard, E.H.; Bartlett, M.L.; Petersen, P.M.; Sanders, W.M.; Payne, R.J.; Martinez, E.

    1978-01-01

    Work has continued on the development and application of the Enzyme-Labeled Antibody (ELA) test to the USDA needs. Results on trichinosis, brucellosis, and staphylococcal enterotoxin A detection are very encouraging. A field test for trichinosis detection is being worked out in cooperation with Food Safety and Quality Service personnel. Work is in progress with the Technicon Instrument Corporation to develop a modification of their equipment to automatically process samples by the ELA procedure. An automated ELA readout instrument for 96-well trays has been completed and is being checked out.

  13. Clinical manifestation, serology marker & microscopic agglutination test (MAT) to mortality in human leptospirosis

    Science.gov (United States)

    Perdhana, S. A. P.; Susilo, R. S. B.; Arifin; Redhono, D.; Sumandjar, T.

    2018-03-01

    Leptospirosis is a potentially fatal zoonosis that is endemic in many tropical regions and causes large epidemics after heavy rainfall and flooding. Severe disease is estimated 5–15% of all human infections. Its mortality rate is 5-40%. MAT, isolation of the organism, or leptospiral DNA in PCR are used to confirm Leptospirosis. This cross-sectional analytic study recruited 26 hospitalized leptospirosis patients admitted to Dr. Moewardi Hospital Surakarta. The diagnosis was based on clinical, laboratory and epidemiological findings. The onset of the disease was the date when the first symptom started, and the end of the analysis was the date when the patient died or discharged. Modified Faine’s score ≥ 25 tend to die (45.5%) while modified Faine’s score 20 – 24 tend to heal (60%) (OR 1.250; CI 0.259-6.029; p=1.0). Seropositive IgM predicts mortality 7.8 times higher than seronegative IgM (OR 7.800; CI 1.162-52.353; p=0.038). MAT positive predict mortality 10.667 times higher than MAT negative (OR 10.667; CI 1.705-66.720; p=0.015). Clinical manifestation, MAT, and serologic marker are all correlated with mortality in Leptospirosis. However, statistically, clinical manifestation has an insignificant correlation.

  14. Q fever in small ruminants in Mali. Results of a serological survey

    Directory of Open Access Journals (Sweden)

    S. S. Sidibé

    2013-01-01

    Full Text Available In Mali, the loss of reproduction is a major constraint to improving the productivity of small ruminants. The causes of these losses are still poorly known and include infertility, abortions, orchitis and stunting. The purpose of this study was to assess the seroprevalence of Q fever in small ruminant farms where cases of loss of reproduction had been observed, as well as financial losses linked to the recorded abortions. The survey was carried out during the period 2006–2009 in the agropastoral areas of Bougouni (Sikasso Region, Nioro (Kayes Region, Keniebougouwere (Segou Region and Koro (Mopti Region. Out of 718 sera analyzed by indirect ELISA, 155 (21.5 ± 3% tested positive for Coxiella burnetii. The prevalence rate varied according to the site and the birth rank. The highest prevalence rate was observed in Keniebougouwere (35 ± 6%, followed by Nioro (28.5 ± 7.5% and Bougouni (10.8 ± 4.6%, and the lowest in Koro (5.8 ± 3.7%. This study revealed the presence of Q fever in small ruminants in Mali. Complementary investigations that include molecular diagnosis (PCR technique might help understand the etiology of the disease involved in cases of loss of reproduction in small ruminants in Mali. The technical and economical analysis helped to assess the financial value of losses.

  15. 42 CFR 493.923 - Syphilis serology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Syphilis serology. 493.923 Section 493.923 Public... Proficiency Testing Programs by Specialty and Subspecialty § 493.923 Syphilis serology. (a) Program content and frequency of challenge. To be approved for proficiency testing in syphilis serology, a program...

  16. Serologic test systems development. Progress report, October 1, 1978-September 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Seawright, G.L.; Sanders, W.M.; Hollstein, U.; Butler, J.E.; Mills, K.W.; Despommier, D.D.; Zimmerman, W.J.; Martinez, E.; Hindman, K.R.; Payne, R.J.

    1980-12-01

    Work has continued on the development and automation of enzyme immunoassays (EIA) for detecting diseases and toxic agents in food animals. Further evaluations were made of the Technicon Autoanalyzer II(AAII) for conducting totally automated EIAs. The problems investigated were machine carryover and assay variation. Modifications greatly reduced or eliminated carryover and produced acceptable levels of test variation. The EIA for swine trichinosis was significantly improved by the use of a new, partially purified antigen preparation. The result was improved detection of early seroconversions and reduced probability for false negatives and false positives. The amplified EIA was adapted as a diagnostic test for bovine brucellosis and studies were initiated for differentiating vaccinated and infected animals. Preliminary data indicate that the IgG/sub 1/ response may be diagnostic but further studies are necessary. Development of the EIA for detecting low molecular weight contaminants and residues in food products was also initiated. Compounds studied were the antibiotics chloramphenicol, tetracycline, and gentamicin; the mycotoxin, aflatoxin, and the shale oil toxin, 2-aminofluorene. Results indicate that chloramphenicol nonspecifically binds to antibody and interferes with antibody activity. Thus, the test is not yet satisfactory. Initial attempts to automate the gentamicin test were unsuccessful because of machine carryover but modifications of the AAII have produced encouraging preliminary data. Work is continuing on the development of EIAs for all of the compounds mentioned above. (ERB)

  17. Factors associated with failure of clinical screening among blood donors who have altered serological results in the Centro Regional de Hemoterapia de Ribeirão Preto

    Directory of Open Access Journals (Sweden)

    Oranice Ferreira

    2012-01-01

    Full Text Available OBJECTIVE: This study aimed to investigate the frequency of positive results for hepatitis B and C, HIV and syphilis in blood donations at the Centro Regional de Hemoterapia de Ribeirão Preto, to describe donors with positive results according to some demographic and socioeconomic variables, to identify risk factors associated to these donors and the reasons that they were not detected during clinical screening. METHODS: A descriptive study was performed between July 1st 2005 and July 31st 2006 by interviewing 106 donors after medical consultations where they were informed of positive results for hepatitis B, hepatitis C, HIV or syphilis. RESULTS: There was a predominance of first-time donors, males, under 50-year olds, married individuals, from Ribeirão Preto, with elementary education, low economic status and of people who donated at the request of friends or relatives. Hepatitis C was the most frequently detected infection (56.6%, followed by hepatitis B (20.7%, HIV (12.3% and syphilis(10.4%. About 40% of donors had omitted risk factors for different reasons: because they trusted the results of serological tests, did not feel comfortable about talking of risk factors or did not consider them relevant. Other justifications were the duration of the interview, the interviewer was unskilled, embarrassment and doubts about confidentiality. CONCLUSION: The results indicate the need for changes in the approach to clinical screening and a review of methods to attract and guide potential donors.

  18. The prevalence of canine Leishmania infantum infection in western China detected by PCR and serological tests

    Directory of Open Access Journals (Sweden)

    Chen Hai-Tang

    2011-05-01

    Full Text Available Abstract Background Canine leishmaniasis (CanL is endemic in western China, resulting in important public health problem. It is essential to evaluate the prevalence of canine Leishmania infantum infection for designing control policy. In the present study we report for the first time prevalence of Leishmania infection in dogs living in Jiuzhaigou County (Sichuan Provence, China, which is not only an important endemic area of CanL but also a tourism scenic spot, detected by PCR, ELISA and dipstick test. The results could provide key information for designing control programs against canine and human leishmaniasis. In addition, the complete sequence of the Leishmania isolate from Sichuan Province has not been reported to date and we present the sequences of 116 base-pair (bp fragment of the conserved region in the minicircle kinetoplast DNA (kDNA and the results of phylogenetic analyses based on the sequence of the amplified fragment. Results The proportion of dogs infected with Leishmania in Jiuzhaigou County was 36.79%, 9.43%, and 51.88% detected by ELISA, dipstick test, and PCR, respectively. The ELISA and PCR tests were more sensitive than dipstick test. The PCR method is the most sensitive way to detect dogs infected with Leishmania parasites. The total positive rate for infected dogs in the area was 59.43% by the three methods. The PCR products of 116-bp fragment amplified from the kDNA conserved region of dog blood samples and laboratory maintained L. infantum were DNA sequenced and the variation of the sequences was observed. The phylogenetic tree based on the sequences of 116-bp fragment reveals that L. infantum is more genetically related to visceralizing species L. donovani than to the Leishmania species associated with cutaneous disease. Conclusions More than half of dogs living in the endemic Jiuzhaigou County were infected by L. infantum. Control measures, such as treatment or eradication of infected dogs, or prohibition of

  19. Comparative evaluation of the INNO-LIA syphilis score and the MarDx Treponema pallidum immunoglobulin G Marblot test assays for the serological diagnosis of syphilis.

    Science.gov (United States)

    Lam, T K; Lau, H Y; Lee, Y P; Fung, S M; Leung, W L; Kam, K M

    2010-02-01

    We evaluated the performance of two immunoblot assays: the INNO-LIA Syphilis Score (LIA) and the MarDx T. pallidum IgG Marblot Test (TWB), as compared with that of the Murex ICE Syphilis enzyme immunoassay (EIA), the Serodia Treponema pallidum particle agglutination (TPPA) assay and the fluorescent treponemal antibody-absorption (FTA-abs) assay, for the serological diagnosis of syphilis using serum samples of 135 attendees of the social hygiene clinics of the Department of Health in Hong Kong newly diagnosed with syphilis and provided with clinical stages (39 in primary, 20 in secondary, 18 in early latent and 58 in latent of unknown duration) and of 43 normal healthy subjects between October and December 2004. The differences in the overall sensitivities of the LIA assay and the EIA/TPPA/FTA-abs assays were not statistically significant (P > 0.05) whereas the overall sensitivity of the TWB assay was significantly lower (P FTA-abs assays. The LIA assay had an overall sensitivity of 94.1% (95% CI 88.7-97.0%) whereas the TWB assay 65.2% (95% CI 56.8-72.7%). Both the LIA and the TWB assays have a specificity of 100%. When consensus results were derived from the most predominant results of the EIA, the TPPA and the FTA-abs assays, the LIA assay had a positive agreement with the consensus results of 98.5% (95% CI 94.5-99.6%) whereas the TWB assay 68.2% (95% CI 59.8-75.6%). Therefore, the LIA assay performed significantly better (P < 0.05) than the TWB assay. The LIA assay can be considered to be a valid alternative confirmatory test for the serological diagnosis of syphilis.

  20. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  1. Evaluation of serological and molecular tests used to identify Toxoplasma gondii infection in pregnant women attended in a public health service in São Paulo state, Brazil.

    Science.gov (United States)

    Murata, Fernando Henrique Antunes; Ferreira, Marina Neves; Pereira-Chioccola, Vera Lucia; Spegiorin, Lígia Cosentino Junqueira Franco; Meira-Strejevitch, Cristina da Silva; Gava, Ricardo; Silveira-Carvalho, Aparecida Perpétuo; de Mattos, Luiz Carlos; Brandão de Mattos, Cinara Cássia

    2017-09-01

    Toxoplasmosis during pregnancy can have severe consequences. The use of sensitive and specific serological and molecular methods is extremely important for the correct diagnosis of the disease. We compared the ELISA and ELFA serological methods, conventional PCR (cPCR), Nested PCR and quantitative PCR (qPCR) in the diagnosis of Toxoplasma gondii infection in pregnant women without clinical suspicion of toxoplasmosis (G1=94) and with clinical suspicion of toxoplasmosis (G2=53). The results were compared using the Kappa index, and the sensitivity, specificity, positive predictive value and negative predictive value were calculated. The results of the serological methods showed concordance between the ELISA and ELFA methods even though ELFA identified more positive cases than ELISA. Molecular methods were discrepant with cPCR using B22/23 primers having greater sensitivity and lower specificity compared to the other molecular methods. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Engineering model cryocooler test results

    International Nuclear Information System (INIS)

    Skimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1992-01-01

    This paper reports that recent testing of diaphragm-defined, Stirling-cycle machines and components has demonstrated cooling performance potential, validated the design code, and confirmed several critical operating characteristics. A breadboard cryocooler was rebuilt and tested from cryogenic to near-ambient cold end temperatures. There was a significant increase in capacity at cryogenic temperatures and the performance results compared will with code predictions at all temperatures. Further testing on a breadboard diaphragm compressor validated the calculated requirement for a minimum axial clearance between diaphragms and mating heads

  3. An ELISA-inhibition test using monoclonal antibody for the serology of leprosy

    NARCIS (Netherlands)

    Klatser, P. R.; de Wit, M. Y.; Kolk, A. H.

    1985-01-01

    In this study a mouse monoclonal antibody (47-9) is described, which recognized an epitope on the 36 kD protein antigen of M. leprae. The monoclonal antibody showed specificity for M. leprae. An ELISA-inhibition test based on the competitive inhibition by antibodies from human test sera of the

  4. Usefulness of a single-assay chemiluminescence test (Tularaemia VIRCLIA IgG + IgM monotest) for the diagnosis of human tularemia. Comparison of five serological tests.

    Science.gov (United States)

    Cubero, África; Durántez, Carlos; Almaraz, Ana; Fernández-Lago, Luis; Gutiérrez, María P; Castro, María J; Bratos, Miguel A; Simarro, María; March, Gabriel A; Orduña, Antonio

    2018-04-01

    The aim of this work was to ascertain the usefulness of a new commercially-available single-assay chemiluminescence test (CHT) for the diagnosis of human tularemia (Tularaemia VIRCLIA IgG + IgM monotest, Vircell, Santa Fe, Granada, Spain). A total of 773 sera from 773 patients including 364 initial sera from patients with diagnosed tularemia, patients with suspected tularemia not confirmed (100), healthy people (152), patients with serology positive to Brucella (97), patients diagnosed with other infectious diseases (30), and patients diagnosed with autoimmune diseases (30) were included. All sera were tested by CHT, "in-house" microagglutination test (MAT), immunochromatographic test (ICT) (Virapid Tularaemia, Vircell, Santa Fe Granada, Spain), and "in-house" ELISA IgG, and ELISA IgM. Of the total initial sera, 334 (sensitivity 91.8%) were positive in the CHT, 332 (sensitivity 91.2%) in the MAT, 330 (sensitivity 90.7%) in the ICT, and 328 (sensitivity 90.1%) in the ELISA IgG and ELISA IgM tests. The specificity of the CHT was 96.7%; of the MAT, 100%; of the ICT, 98.7%; and of the ELISA IgG and ELISA IgM, 97.4%. In the group of patients with serology positive to Brucella, at least 12.4% of sera were positive in tularemia tests (12.4% in ELISA IgM, 13.4% in MAT, 14.4% in ICT, and 15.5% in CHT and ELISA IgG). In conclusion, CHT presents a sensitivity and specificity in early diagnosis of human tularemia, similar to MAT, ICT, and ELISA IgG and ELISA IgM. Its single assay design allows lower costs, especially in areas of low endemicity or inter-epidemic periods.

  5. Sensitivity of field tests, serological and molecular techniques for Plum Pox Virus detection in various tissues

    Directory of Open Access Journals (Sweden)

    Mojca VIRŠČEK MARN

    2015-12-01

    Full Text Available Sensitivity of field tests (AgriStrip  and Immunochromato, DAS-ELISA, two step RT-PCR and real-time RT-PCR for Plum pox virus (PPV detection was tested in various tissues of apricot, peach, plum and damson plum trees infected with isolates belonging to PPV-D, PPV-M or PPV-Rec, the three strains present in Slovenia. Flowers of apricot and plum in full bloom proved to be a very good source for detection of PPV. PPV could be detected with all tested techniques in symptomatic parts of leaves in May and with one exception even in the beginning of August, but it was not detected in asymptomatic leaves using field tests, DAS-ELISA and partly also molecular techniques. PPV was detected only in some of the samples of asymptomatic parts of the leaves with symptoms and of stalks by field tests and DAS-ELISA. Infections were not detected in buds in August using field tests or DAS-ELISA. Field tests are useful for confirmation of the PPV infection in symptomatic leaves, but in tissues without symptoms DAS-ELISA should be combined or replaced by molecular techniques.

  6. Administration of time-expired yellow fever vaccine: public health response and results of a serological investigation.

    Science.gov (United States)

    Allen, K W; Nguyen-Van-Tam, J S; Howells, J

    1999-06-01

    The discovery that a local travel clinic had administered 101 doses of time-expired yellow fever vaccine over a six month period prompted an immediate investigation in order to advise vaccinees about to travel to areas where yellow fever is endemic. No data were available to provide adequate reassurance about the potential efficacy of time-expired vaccine, so a rapid serological investigation was conducted, which provided evidence that the yellow fever vaccine had remained potent beyond its expiry date.

  7. Summary of CCTF test results

    International Nuclear Information System (INIS)

    Iguchi, T.; Murao, Y.; Sugimoto, J.; Akimoto, H.; Okubo, T.; Hojo, T.

    1987-01-01

    Conservatism of current safety analysis was assessed by comparing the predicted result with cylindrical core test facility (CCTF) test result performed at Japan Atomic Energy Research Institute. WREM code was selected for the assessment. The overall conservatism of the WREM code on the peak clad temperature prediction was confirmed against CCTF evaluation model (EM) test which simulated the typical initial and boundary conditions in the safety evaluation analysis. WREM code predicted the reasonable core boundary conditions and the conservatism of the code came mainly from core calculation. The conservatism of the WREM code against CCTF data could be attributed to the following three points: (1) no horizontal mixing assumption between subchannels at each elevation; (2) no modeling on heat transfer enhancement caused by the radial core power profile; and (3) conservative heat transfer correlations in the code

  8. Mobile evaporator corrosion test results

    International Nuclear Information System (INIS)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80 degrees C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either open-quotes satisfactoryclose quotes (2-20 mpy) or open-quotes excellentclose quotes (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment

  9. Analyzing actual risk in malaria-deferred donors through selective serologic testing.

    Science.gov (United States)

    Nguyen, Megan L; Goff, Tami; Gibble, Joan; Steele, Whitney R; Leiby, David A

    2013-08-01

    Approximately 150,000 US blood donors are deferred annually for travel to malaria-endemic areas. However, the majority do not travel to the high-risk areas of Africa associated with transfusion-transmitted malaria (TTM) but visit low-risk areas such as Mexico. This study tests for Plasmodium infection among malaria-deferred donors, particularly those visiting Mexico. Blood donors deferred for malaria risk (travel, residence, or previous infection) provided blood samples and completed a questionnaire. Plasma was tested for Plasmodium antibodies by enzyme immunoassay (EIA); repeat-reactive (RR) samples were considered positive and tested by real-time polymerase chain reaction (PCR). Accepted donors provided background testing data. During 2005 to 2011, a total of 5610 malaria-deferred donors were tested by EIA, including 5412 travel deferrals. Overall, 88 (1.6%) were EIA RR; none were PCR positive. Forty-nine (55.7%) RR donors previously had malaria irrespective of deferral category, including 34 deferred for travel. Among 1121 travelers to Mexico, 90% visited Quintana Roo (no or very low risk), but just 2.2% visited Oaxaca/Chiapas (moderate or high risk). Only two Mexican travelers tested RR; both previously had malaria not acquired in Mexico. Travel to Mexico represents a large percentage of US donors deferred for malaria risk; however, these donors primarily visit no- or very-low-risk areas. No malaria cases acquired in Mexico were identified thereby supporting previous risk estimates. Consideration should be given to allowing blood donations from U.S. donors who travel to Quintana Roo and other low-risk areas in Mexico. A more effective approach to preventing TTM would be to defer all donors with a history of malaria, even if remote. © 2012 American Association of Blood Banks.

  10. Evaluation of serological tests for the diagnosis of rickettsiosis in Denmark

    DEFF Research Database (Denmark)

    Kantsø, Bjørn; Svendsen, Claus Bo; Jørgensen, Charlotte Svaerke

    2009-01-01

    Two commercially available immunofluorescence assays (IFA) were compared using historical sera evaluated for rickettsial antibodies by the Weil-Felix test. An IFA test produced by Focus Diagnostics prepared with Rickettsia rickettsii and R. typhi antigens was compared with a custom made kit from....... When analyzing the data using the manufacturers' cut-off values, 41% of samples from presumably healthy blood donors were found positive for spotted fever group Rickettsia antibodies. This does not correlate to the general picture of rickettsiosis in Denmark. Furthermore, sera with Coxiella burnetii...

  11. Periodontal disease and Helicobacter pylori infection: a community-based study using serology and rapid urease test.

    Science.gov (United States)

    Nisha, Krishnavilasom J; Nandakumar, Krishnankutty; Shenoy, Kottacherry T; Janam, Presanthila

    2016-02-01

    The aims of the present study were to assess the prevalence of periodontal disease and Helicobacter pylori (H. pylori) infection and their associations within a predefined Indian population. A community-based cross-sectional study of 500 selected individuals using a questionnaire, oral examination, rapid urease testing of dental plaque, and serological examination for immunoglobulin G antibody to H. pylori was carried out. Periodontal disease and H. pylori infection were prevalent in more than 50% of the population. Age, smoking, and diabetic status of the individuals were risk factors for periodontal disease after multivariate analysis, and a lack of proper sewage and waste disposal facilities were found to increase the risk of H. pylori infection. Although there was no association between periodontal disease and H. pylori seropositivity in the community, a highly-significant association was found between periodontal disease and colonization of H. pylori in dental plaque. Because periodontal disease is associated with the increased colonization of H. pylori, new treatment modalities, such as plaque control measures, should be employed for the complete management of H. pylori-associated gastric disease. © 2014 Wiley Publishing Asia Pty Ltd.

  12. Using Crossmatch tests for serological compatibility assessment intra- and interspecific at dogs and cats

    Directory of Open Access Journals (Sweden)

    Sergiu Adrian Muntean

    2016-11-01

    Conclusions: The intraspecific evaluations revealed a high level of blood compatibility in the case of dogs unsensitivized through previous blood transfusions, yet without excluding the possibility of some atypical sensitivization for clinical interest. Having all the interspecific tests exclusively highly positive, we can not sustain a probable xenotransfusion.

  13. Correlation between chronic arthritis patients confirmed with questionnaire and serologic test of Lyme disease

    Science.gov (United States)

    Rotan, H.; Ginting, Y.; Loesnihari, R.; Kembaren, T.; Marpaung, B.

    2018-03-01

    Lyme borreliosis is the most common tick-borne disease, and frequency of arthritis complication later. The objective of this study was to determine the seroprevalence of Lyme disease and to evaluate its correlation with chronic arthritis. This epidemiologic cross sectional study included 41 healthy individuals who had chronic arthritis and bitten by ticks underwent questionnaires, and laboratory tests consisted of a routine blood sample, serum uric acid, and IgG ELISA for Lyme. There was 7.32% presence of positive IgG for Lyme. Samples with positive IgG for Lyme were further evaluated for rheumatology marker. We found three samples with a positive rheumatoid factor, two samples had positive anti-MCV, and 1 sample had slightly increased CRP. Three Lyme positive samples had normal EULAR scoring. It was the first Lyme disease case found in Indonesia, particularly in 4 villages of Sibolangit, Deli Serdang, North Sumatera. The assessment made by analysis the questionnaire, evaluation the blood test, and confirmed positive Lyme disease, and at last, we found the correlation between chronic arthritis with positive test Lyme.

  14. 21 CFR 866.3255 - Escherichia coli serological reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Escherichia coli serological reagents. 866.3255... coli serological reagents. (a) Identification. Escherichia coli serological reagents are devices that consist of antigens and antisera used in serological tests to identify Escherichia coli from cultured...

  15. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  16. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  17. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  18. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  19. STANDARDIZATION OF PROCEDURES OF Plasmodium falciparum ANTIGEN PREPARATION FOR SEROLOGIC TESTS

    Directory of Open Access Journals (Sweden)

    Sandra L.M. AVILA

    1998-09-01

    Full Text Available The objective of the present study is to standardize the technical variables for preparation and storage of Plasmodium falciparum and of antigen components extracted with the amphoteric detergent Zwittergent. P. falciparum obtained from in vitro culture was stored at different temperatures and for different periods of time. For each variable, antigen components of the parasite were extracted in the presence or absence of protease inhibitors and submitted or not to later dialysis. Products were stored for 15, 30 and 60 days at different temperatures and immunological activity of each extract was determined by SDS-PAGE and ELISA using positive or negative standard sera for the presence of IgG directed to blood stage antigens of P. falciparum. Antigen extracts obtained from parasites stored at -20oC up to 10 days or at -70oC for 2 months presented the best results, showing well-defined bands on SDS-PAGE and Western blots and presenting absorbance values in ELISA that permitted safe differentiation between positive and negative sera.O objetivo deste estudo foi padronizar variáveis técnicas para o armazenamento de Plasmodium falciparum e de seus componentes antigênicos. Sedimentos de parasitas foram obtidos do cultivo in vitro de P.falciparum e estocados em diferentes temperaturas por diferentes períodos de tempo. De cada variável, foram extraídos os componentes antigênicos com detergente anfótero Zwittergent na presença e na ausência de inibidores de proteases e submetidos ou não a posterior diálise. Os produtos foram estocados por 15, 30 e 60 dias em diferentes temperaturas e caracterizados por SDS-PAGE. A atividade antigênica de cada extrato foi determinada por ELISA e Western blotting usando soros positivos e negativos para anticorpos IgG anti-formas eritrocitárias de P.falciparum. Os extratos antigênicos obtidos de parasitas estocados até 10 dias a _20ºC ou por 2 meses a _70ºC e tratados com inibidores de proteases, sob as

  20. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.

    Science.gov (United States)

    Tiwari, Aseem K; Pandey, Prashant K; Dara, Ravi C; Rawat, Ganesh S; Raina, Vimarsh; Bhargava, Richa

    2015-01-01

    Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. This study was designed to evaluate the performance of newly introduced VITROS(®) syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at -20°C, were used to evaluate the performance of VITROS(®) syphilis TPA assay based on enhanced chemiluminescence assay on VITROS(®) ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. VITROS(®) syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of endogenous interfering substances like free hemoglobin or fats. Performance of the VITROS(®) syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  1. Demographic, risk factors and motivations among blood donors with reactive serologic tests for syphilis in São Paulo, Brazil.

    Science.gov (United States)

    Ferreira, S C; de Almeida-Neto, C; Nishiya, A S; Oliveira, C D L; Ferreira, J E; Alencar, C S; Levi, J E; Salles, N A; Mendrone, A; Sabino, E C

    2014-06-01

    To identify the demographic characteristics, risk factors and motivations for donating among blood donors with reactive serologic tests for syphilis. Post-donation interviews with syphilis seropositive blood donors improve recruitment and screening strategies. This case-control study compares 75 Venereal Disease Research Laboratory (VDRL) > 8, EIA+ (enzyme immunoassay) and FTA-ABS+ (fluorescent treponemal antibody); 80 VDRL-, EIA+ and FTA-ABS+; and 34 VDRL- and EIA- donors between 2004 and 2009. Donors were assessed by their demographic characteristics, sexual behaviour, history of alcohol and illicit drugs use, and motivations to donate. Donors with VDRL > 8 were more likely to be divorced [AOR = 12·53; 95% confidence interval (CI) 1·30-120·81], to have had more than six sexual partners (AOR=7·1; 95% CI 1·12-44·62) and to report male-male-sex in the past 12 months (AOR=8·18; 95% CI 1·78-37·60). Donors with VDRL-, EIA+ and FTA-ABS+ were less likely to be female (AOR=0·26; 95% CI 0·07-0·96), more likely to be older (AOR=10·2; 95% CI 2·45-42·58 ≥ 39 and illicit drugs use; 30·7% (VDRL > 8) and 12·5% (VDRL-, EIA+ and FTA-ABS+) of donors reported that they had been at risk for HIV infection (P = 0·004). One-third of donors came to the blood bank to help a friend or a relative who needed blood. Although donors exposed to syphilis reported and recognised some high risk behaviour, most were motivated by direct appeal to donate blood. Monitoring the risk profile of blood donors can benefit public health and improve blood safety. © 2014 The Authors. Transfusion Medicine © 2014 British Blood Transfusion Society.

  2. Test Results for CSTR Test 4

    International Nuclear Information System (INIS)

    Lee, D.D.

    2001-01-01

    One of the 3 technologies currently being developed for the Savannah River Salt Waste Processing Program is the Small-Tank Tetraphenylborate Process (STTP). This process uses sodium tetraphenylborate to precipitate and remove radioactive Cs from the waste and monosodium titanate to sorb and remove radioactive Sr and actinides. ORNL is demonstrating this process at the 1:4000 scale using a 20-liter continuous-flow stirred tank reactor (CSTR) system. The primary goal of Test 4 was to verify that the STTP process could achieve and maintain the necessary Cs decontamination while TPB was actively decomposing. Even with TPB being decomposed by the off-normal conditions of this test, the decontaimination factor for 137 Cs obtained for the filtrate from the Slurry Concentrating Tank ranged from 47,000 to 646,000, exceeding the WAC standard

  3. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  4. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  5. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  6. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  7. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  8. Railgun bore material test results

    International Nuclear Information System (INIS)

    Wang, S.Y.; Burton, R.L.; Witherspoon, F.D.; Bloomberg, H.W.; Goldstein, S.A.; Tidman, D.A.; Winsor, N.K.

    1987-01-01

    GT-Devices, Inc. has constructed a material test facility (MTF) to study the fundamental heat transfer problem of both railgun and electrothermal guns, and to test candidate gun materials under real plasma conditions. The MTF electrothermally produces gigawatt-level plasmas with pulse lengths of 10-30 microseconds. Circular bore and non-circular bore test barrels have been successfully operated under a wide range of simulated heating environments for EM launchers. Diagnostics include piezoelectric MHz pressure probes, time-of-flight probes, and current and voltage probes. Ablation measurements are accomplished by weighing and optical inspection, including borescope, optical microscope, and scanning electron microscope (SEM). From these measurements the ablation threshold for both the rail and insulator materials can be determined as a function of plasma heating. The MTF diagnostics are supported by an unsteady 1-D model of MTF which uses the flux-corrected transport (FCT) algorithm to calculate the fluid equations in conservative form. A major advantage of the FCT algorithm is that it can model gas dynamic shock behaviour without the requirement of numerical diffusion. The principle use of the code is to predict the material surface temperature ΔT/α from the unsteady heat transfer q(t)

  9. Agreement Between Serology and Histology for Detection of Helicobacter pylori Infection

    International Nuclear Information System (INIS)

    Iqbal, S.; Fatima, S.; Raheem, A.; Khan, A. H.

    2013-01-01

    Objective: To determine the percentage agreement between serology and histology for detection of Helicobacter (H.) pylori infection. Study Design: Cross-sectional analytical study. Place and Duration of Study: Department of Pathology and Microbiology, The Aga Khan University and Hospital, Karachi, from January to December 2009. Methodology: Fifty subjects were selected by non-probability purposive sampling from laboratory data who had serological testing of H. pylori IgG antibody, prior to histological evaluation of endoscopic gastric or/and duodenal biopsies. Serological Quantification of H. pylori IgG was carried out with HpG screen ELISA kit (Genesis Diagnostics, UK), using an enzyme linked immunosorbent assay for detection of IgG antibodies against H. pylori. Manufacturer's recommended cutoff value was used and results were considered positive when greater than 7 U/ml. For histological diagnosis, an expert histopathologist characterized the presence of spiral bacteria in the mucosal layer or the surface of epithelial cells on microscopic examination, as a positive test. Results: An agreement of 0.72 was found by Kappa statistics between serology and histopathology results and a good diagnostic accuracy (86%) of serological testing was observed for the diagnosis of H. pylori infection. Conclusion: A substantial agreement was found between serology and histopathology results to detect the H. pylori infection. Laboratory-based serologic testing using ELISA technology to detect IgG antibodies is inexpensive, noninvasive and convenient method to detect the H. pylori infection in primary care setting. (author)

  10. Boraflex test results and evaluation

    International Nuclear Information System (INIS)

    Lindquist, K.; Kline, D.E.; Haley, T.C.

    1993-02-01

    New data developed, collected, and evaluated to further assess the in-pool performance of the neutron absorber material, Boraflex. The data are from new EPRI test programs, utility surveillance programs, and blackness testing at a number of plants. This new data provides a basis for quantifying the gap phenomenon in full length panels of Boraflex in spent fuel racks; the maximum anticipated gap size, frequency of gap occurrence, and axial distribution of gaps. Methods have been developed to assess the reactivity effects of gaps and Boraflex shrinkage. The analyses presented demonstrates that the reactivity effect of gaps is very small, not much larger than the statistical variations inherent in the calculational method. The data and analyses presented serve to close the issue of gap formation and shrinkage in panels of Boraflex and the effect of such gaps and shrinkage on the reactivity of the fuel/rack configuration. Ongoing EPRI programs to assess the long term performance of Boraflex in spent fuel storage racks are described

  11. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  12. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  13. 21 CFR 866.3470 - Reovirus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3470 Reovirus... and antisera used in serological tests to identify antibodies to reovirus in serum. The identification...

  14. 21 CFR 866.3870 - Trypanosoma spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3870 Trypanosoma... consist of antigens and antisera used in serological tests to identify antibodies to Trypanosoma spp. in...

  15. 21 CFR 866.3630 - Serratia spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3630 Serratia spp... antigens and antisera used in serological tests to identify Serratia spp. from cultured isolates. The...

  16. 21 CFR 866.3850 - Trichinella spiralis serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3850... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  17. 21 CFR 866.3680 - Sporothrix schenckii serological reagents.

    Science.gov (United States)

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3680... devices that consist of antigens and antisera used in serological tests to identify antibodies to...

  18. 21 CFR 866.3660 - Shigella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3660 Shigella spp...), used in serological tests to identify Shigella spp. from cultured isolates. The identification aids in...

  19. 21 CFR 866.3400 - Parainfluenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3400 Parainfluenza... that consist of antigens and antisera used in serological tests to identify antibodies to parainfluenza...

  20. 21 CFR 866.3040 - Aspergillus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3040 Aspergillus... consist of antigens and antisera used in various serological tests to identify antibodies to Aspergillus...

  1. 21 CFR 866.3330 - Influenza virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3330 Influenza... consist of antigens and antisera used in serological tests to identify antibodies to influenza in serum...

  2. 21 CFR 866.3065 - Bordetella spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3065 Bordetella... serological tests to identify Bordetella spp. from cultured isolates or directly from clinical specimens. The...

  3. 21 CFR 866.3380 - Mumps virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3380 Mumps virus... serological tests to identify mumps viruses from tissue culture isolates derived from clinical specimens. The...

  4. Salt decontamination demonstration test results

    International Nuclear Information System (INIS)

    Snell, E.B.; Heng, C.J.

    1983-06-01

    The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less than 10 3 d/m/ml versus a goal of less than 10 4 d/m/ml; and (4) the concentrated precipitate was washed to a final sodium ion concentration of 0.15 M, well below the 0.225 M upper limit for DWPF feed. These accomplishments were achieved on schedule and without incident. Total radiation exposure to personnel was less than 350 mrem and resulted primarily from sampling precipitate slurry inside tank 48. 3 references, 6 figures, 2 tables

  5. Serological evidence of herpesvirus infection in gibbons

    Directory of Open Access Journals (Sweden)

    Ratanakorn Parntep

    2002-05-01

    Full Text Available Abstract Background Herpesviruses are not only infectious agents of worldwide distribution in humans, but have also been demonstrated in various non-human primates as well. Seventy-eight gibbons were subjected to serological tests by ELISA for herpes simplex virus type 1 (HSV-1, herpes simplex virus type 2 (HSV-2, Epstein-Barr virus (EBV and cytomegalovirus (CMV. Results The prevalence of IgG antibodies against HSV-1, HSV-2, EBV and CMV was 28.2%, 28.2%, 14.1% and 17.9%, respectively. Conclusions Antigenic cross-reactivity is expected to exist between the human herpesviruses and gibbon herpesviruses. Gibbons have antibodies to human herpesviruses that may reflect zoonotic infection with human herpesviruses or infection with indigenous gibbon herpesviruses. Therefore, it is difficult to draw concrete conclusions from serological studies alone. Identification should be based on further isolation and molecular characterization of viruses from seropositive animals.

  6. Post-mortem diagnosis of chronic Chagas's disease comparative evaluation of three serological tests on pericardial fluid.

    Science.gov (United States)

    Lopes, E R; Chapadeiro, E; Batista, S M; Cunha, J G; Rocha, A; Miziara, L; Ribeiro, J U; Patto, R J

    1978-01-01

    In an attempt to improve the post-mortem diagnosis of Chagas's disease the authors performed haemagglutination tests (HAT), fluorescent Trypanosoma cruzi antibody tests (FAT), and complement fixation tests (CFT) on the pericardial fluid obtained at autopsy of 50 individuals with Chagas's heart disease, and 93 patients in whom this disease was not thought to be present. The results demonstrate that all three tests are efficient for the post-mortem diagnosis of Chagas's disease but suggest that their combined use would detect more cases than would one isolated reaction only.

  7. Serological Survey of Toxoplasmosis Transvaal

    African Journals Online (AJOL)

    Serological Survey of Toxoplasmosis. Transvaal. P. R. MASON, M. R. JACOBS, P. J. FRIPP. •. In the. SUMMARY. Thirty-seven per cent of 605 samples of human sera col- lected from four ethnic groups in South Africa gave a positive Toxoplasma indir~ct fluorescent antibody test at a dilution 01 1/16 or higher. The incidences ...

  8. Detection of Yersinia enterocolitica serotype O:9 in the faeces of cattle with false positive reactions in serological tests for brucellosis in Ireland.

    Science.gov (United States)

    O'Grady, Don; Kenny, Kevin; Power, Seamus; Egan, John; Ryan, Fergus

    2016-10-01

    Intestinal infection by Yersinia enterocolitica serotype O:9 (YeO9) in cattle has been linked to false positive serological reactivity (FPSR) in diagnostic tests for brucellosis. Although eradicated in Ireland, brucellosis monitoring still identifies seropositive animals, usually one or two (termed singletons) per herd, which are classed as FPSR. To investigate a link between FPSR and YeO9, faeces and blood were collected from singleton FPSR cattle, and from companion animals, in eight selected herds with more than one FPSR animal, for YeO9 culture and Brucella serology. YeO9 was isolated from 76/474 (16%) FPSR singletons in 309 herds, but not from any of 621 animals in 122 control non-FPSR herds. In the FPSR herds 52/187 (27.8%) animals were culture positive, and 17% of the isolates were from seronegative animals. Seropositive animals were more likely to have a rising antibody titre when culture positive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  10. Serological survey of Brucellosis in livestock animals and workers in ...

    African Journals Online (AJOL)

    Abstract. A serological survey of brucellosis in livestock animals and workers was conducted in Ibadan, Southwestern Nigeria between May and August 2004. A total of 1,210 cattle, 54 sheep, 496 goats, 200 pigs and 21 humans (i.e. butchers and herdsmen) were screened using the Rose Bengal test (RBT).From the results ...

  11. [Comparison of conventional and non-conventional serological tests for the diagnosis of imported Chagas disease in Spain].

    Science.gov (United States)

    Flores-Chávez, María; Cruz, Israel; Rodríguez, Mercedes; Nieto, Javier; Franco, Elena; Gárate, Teresa; Cañavate, Carmen

    2010-05-01

    Trypanosoma cruzi infection is a major imported parasitic disease in Spain, because of the increase of immigrants from endemic areas. Since the laboratory diagnosis during the chronic phase is based on detection of anti-T. cruzi IgG antibodies, our aims were to compare 10 tests for determining anti-T. cruzi antibodies, to assess their cross-reactivity with related diseases, and to evaluate the rk39-ELISA and IFAT-Leishmania tests as tools for the differential diagnosis of leishmaniasis due to Leishmania infantum. A total of 223 sera were tested: 40 had been previously characterized by Qpanel, and 183 were obtained from the serum library of the Parasitology Department, Centro Nacional de Microbiología (66 chagasic, 97 healthy, 30 visceral leishmaniasis, and 30 malaria). Samples were examined using in-house IFAT and ELISA, 5 commercial ELISAs (Certest/Abbot Laboratories/BiosChile; Ortho Clinical Diagnostics; BLK Diagnostic; bioMérieux; and Biokit), particle gel agglutination (ID-PaGIA), and two immunochromatographic assays (Operon and CTK Biotech). The last 4 tests are based in recombinant antigens (non-conventional tests). The IFAT and ELISAs showed a sensitivity of 97% to 100%. The immunochromatographic tests had somewhat lower sensitivity (92%-96%). All non-conventional tests presented a smaller number of cross-reactions. Leishmania-Rk39-ELISA did not show cross-reactivity with chagasic sera. In general, our results confirm the data obtained by other authors. The sensitivity of ELISA is higher than other tests; therefore, these techniques would be the most appropriate for screening of T. cruzi infection. A suitable approach is the combination of a test using total antigen with another based on either recombinant antigens or synthetic peptides. (c) 2009 Elsevier España, S.L. All rights reserved.

  12. Relevance of and New Developments in Serology for Toxoplasmosis.

    Science.gov (United States)

    Dard, Céline; Fricker-Hidalgo, Hélène; Brenier-Pinchart, Marie-Pierre; Pelloux, Hervé

    2016-06-01

    Toxoplasmosis is a widespread parasitic disease caused by the intracellular parasite Toxoplasma gondii with a wide spectrum of clinical outcomes. The biological diagnosis of toxoplasmosis is often difficult and of paramount importance because clinical features are not sufficient to discriminate between toxoplasmosis and other illnesses. Serological tests are the most widely used biological tools for the diagnosis of toxoplasmosis worldwide. This review focuses on the crucial role of serology in providing answers to the most important questions related to the epidemiology and diagnosis of toxoplasmosis in human pathology. Notwithstanding their undeniable importance, serological tools need to be continuously improved and the interpretation of the ensuing results remains complex in many circumstances. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Prevalence and presentation of hepatitis B and C virus (HBV and HCV) infection in Vietnamese Americans via serial community serologic testing.

    Science.gov (United States)

    Nguyen, Kelvin; Van Nguyen, Thai; Shen, Duke; Xia, Victor; Tran, Diep; Banh, Khanh; Ruan, Victor; Hu, Ke-Qin

    2015-02-01

    The prevalence of hepatitis B virus (HBV) infection is reportedly high in Vietnamese Americans (VAs), but most previous studies did not assess full HBV serology, and not the prevalence of HBV and hepatitis C virus (HCV) infection simultaneously. The aim of the study is to assess the prevalence of different HBV serologies and HCV infection in VAs. This study was based on the data collected by testing for Hepatitis B surface antigen (HBsAg), anti-hepatitis B core antibody (HBcAb IgG), anti-HBs antibody (HBsAb), and anti-HCV antibody (anti-HCV) in a series of community screening in VAs in Orange County, California. In 1,405 VA participants, the mean age was 51 (17-87) years, 45.1% were males; 68.2%, married; 97.2%, born in Vietnam. Most of the participants were non-US born with their primary language being non-English and with limited access to health care. Of the 1,405 cases, 124 (8.8%) were confirmed HBV infection by HBsAg+; 81 (5.8%), HCV infection by anti-HCV+; including four (0.3%) with HBV/HCV coinfection. Twelve percent of the participants with confirmed HBV infection thought they were previously tested negative, while 29.7% of the participants with confirmed HCV infection thought they were previously tested negative. In this cohort, 15.4% were HBsAg-/HBsAb-/HBcAb IgG-, i.e. being susceptible to HBV infection. In HCV infected participants, 65.4% were born between 1945 and 1965. This large serial survey and screening in the Vietnamese American community confirmed the rates of HBV and HCV infection to be as high as 8.8% and 5.8%, respectively. We have also identified factors related to HBV and HCV infection in this high-risk population.

  14. Reproducibility of the results in ultrasonic testing

    International Nuclear Information System (INIS)

    Chalaye, M.; Launay, J.P.; Thomas, A.

    1980-12-01

    This memorandum reports on the conclusions of the tests carried out in order to evaluate the reproducibility of ultrasonic tests made on welded joints. FRAMATOME have started a study to assess the dispersion of results afforded by the test line and to characterize its behaviour. The tests covered sensors and ultrasonic generators said to be identical to each other (same commercial batch) [fr

  15. Typhoid outbreak in Songkhla, Thailand 2009-2011: clinical outcomes, susceptibility patterns, and reliability of serology tests.

    Directory of Open Access Journals (Sweden)

    Wannee Limpitikul

    Full Text Available OBJECTIVE: To determine the clinical manifestations and outcomes, the reliability of Salmonella enterica serotype Typhi (S ser. Typhi IgM and IgG rapid tests, and the susceptibility patterns and the response to treatment during the 2009-2011 typhoid outbreak in Songkhla province in Thailand. METHOD: The medical records of children aged <15 years with S ser. Typhi bacteremia were analysed. The efficacy of the typhoid IgM and IgG rapid tests and susceptibility of the S ser. Typhi to the current main antibiotics used for typhoid (amoxicillin, ampicillin, cefotaxime, ceftriaxone, co-trimoxazole, and ciprofloxacin, were evaluated. RESULTS: S ser. Typhi bacteremia was found in 368 patients, and all isolated strains were susceptible to all 6 antimicrobials tested. Most of the patients were treated with ciprofloxacin for 7-14 days. The median time (IQR of fever before treatment and duration of fever after treatment were 5 (4, 7 days and 4 (3, 5 days, respectively. Complications of ascites, lower respiratory symptoms, anemia (Hct <30%, and ileal perforation were found in 7, 7, 22, and 1 patients, respectively. None of the patients had recurrent infection or died. The sensitivities of the typhoid IgM and IgG tests were 58.3% and 25.6% respectively, and specificities were 74.1% and 50.5%, respectively. CONCLUSION: Most of the patients were diagnosed at an early stage and treated with a good outcome. All S ser. Typhi strains were susceptible to standard first line antibiotic typhoid treatment. The typhoid IgM and IgG rapid tests had low sensitivity and moderate specificity.

  16. A simple and inexpensive point-of-care test for hepatitis B surface antigen detection: serological and molecular evaluation.

    Science.gov (United States)

    Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S

    2014-12-01

    Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.

  17. Serological and molecular diagnostic tests for canine visceral leishmaniasis in Brazilian endemic area: one out of five seronegative dogs are infected.

    Science.gov (United States)

    Lopes, E G; Sevá, A P; Ferreira, F; Nunes, C M; Keid, L B; Hiramoto, R M; Ferreira, H L; Oliveira, T M F S; Bigotto, M F D; Galvis-Ovallos, F; Galati, E A B; Soares, R M

    2017-09-01

    Euthanasia of infected dogs is one of the measures adopted in Brazil to control visceral leishmaniasis (VL) in endemic areas. To detect infected dogs, animals are screened with the rapid test DPP® Visceral Canine Leishmaniasis for detection of antibodies against K26/K39 fusion antigens of amastigotes (DPP). DPP-positives are confirmed with an immunoenzymatic assay probing soluble antigens of promastigotes (ELISA), while DPP-negatives are considered free of infection. Here, 975 dogs from an endemic region were surveyed by using DPP, ELISA and real-time PCR (qPCR) for the diagnosis of VL. When DPP-negative dogs were tested by qPCR applied in blood and lymph node aspirates, 174/887 (19·6%) were positive in at least one sample. In a second sampling using 115 cases, the DPP-negative dogs were tested by qPCR in blood, lymph node and conjunctival swab samples, and 36/79 (45·6%) were positive in at least one sample. Low-to-moderate pairwise agreement was observed between all possible pair of tests. In conclusion, the official diagnosis of VL in dogs in Brazilian endemic areas failed to accuse an expressive number of infected animals and the impact of the low accuracy of serological tests in the success of euthanasia-based measure for VL control need to be assessed.

  18. Evaluation of a serological test (indirect ELISA) for the diagnosis of sarcoptic mange in red foxes (Vulpes vulpes).

    Science.gov (United States)

    Bornstein, Set; Frössling, Jenny; Näslund, Katarina; Zakrisson, Göran; Mörner, Torsten

    2006-12-01

    Sarcoptic mange occurs in many parts of the world and is common in populations of domestic and wild canids, including red foxes (Vulpes vulpes). In recent years, an indirect antibody enzyme-linked immunosorbent assay (ELISA), with higher sensitivity and specificity than traditional diagnostic methods, has been successfully applied in the diagnosis of sarcoptic mange in dogs. The same ELISA has also demonstrated specific antibodies to Sarcoptes scabiei in experimentally infected red foxes. The aim of this study was to evaluate the indirect ELISA when used to detect antibodies to S. scabiei in field sera from Swedish red foxes. One cohort of both infected and non-infected red foxes (cohort 1; n = 88), and one cohort of apparently non-infected foxes (cohort 2; n = 67) were examined for skin lesions and presence of S. scabiei by thorough visual examination at autopsy and skin scrapings. Samples of blood-tinted body liquid from the abdomen or thorax cavity were collected and analysed by the indirect ELISA. The relative sensitivity and specificity of the ELISA at different cut-offs (OD values) were estimated by comparing the test results to the infection status as determined by examination and skin scrapings. The highest combination of relative sensitivity and specificity, calculated based on cohort 1, was 95.4 and 100.0%, respectively. These estimates were constant for cut-offs 0.150-0.225, which included the cut-off based on the mean plus three standard deviations of test results from cohort 2 (0.165). It is concluded that this test can be useful in diagnosis and epidemiological studies of S. scabiei infection in red foxes.

  19. Fecal Gluten Peptides Reveal Limitations of Serological Tests and Food Questionnaires for Monitoring Gluten-Free Diet in Celiac Disease Patients

    Science.gov (United States)

    Comino, Isabel; Fernández-Bañares, Fernando; Esteve, María; Ortigosa, Luís; Castillejo, Gemma; Fambuena, Blanca; Ribes-Koninckx, Carmen; Sierra, Carlos; Rodríguez-Herrera, Alfonso; Salazar, José Carlos; Caunedo, Ángel; Marugán-Miguelsanz, J M; Garrote, José Antonio; Vivas, Santiago; lo Iacono, Oreste; Nuñez, Alejandro; Vaquero, Luis; Vegas, Ana María; Crespo, Laura; Fernández-Salazar, Luis; Arranz, Eduardo; Jiménez-García, Victoria Alejandra; Antonio Montes-Cano, Marco; Espín, Beatriz; Galera, Ana; Valverde, Justo; Girón, Francisco José; Bolonio, Miguel; Millán, Antonio; Cerezo, Francesc Martínez; Guajardo, César; Alberto, José Ramón; Rosinach, Mercé; Segura, Verónica; León, Francisco; Marinich, Jorge; Muñoz-Suano, Alba; Romero-Gómez, Manuel; Cebolla, Ángel; Sousa, Carolina

    2016-01-01

    Objectives: Treatment for celiac disease (CD) is a lifelong strict gluten-free diet (GFD). Patients should be followed-up with dietary interviews and serology as CD markers to ensure adherence to the diet. However, none of these methods offer an accurate measure of dietary compliance. Our aim was to evaluate the measurement of gluten immunogenic peptides (GIP) in stools as a marker of GFD adherence in CD patients and compare it with traditional methods of GFD monitoring. Methods: We performed a prospective, nonrandomized, multicenter study including 188 CD patients on GFD and 84 healthy controls. Subjects were given a dietary questionnaire and fecal GIP quantified by enzyme-linked immunosorbent assay (ELISA). Serological anti-tissue transglutaminase (anti-tTG) IgA and anti-deamidated gliadin peptide (anti-DGP) IgA antibodies were measured simultaneously. Results: Of the 188 celiac patients, 56 (29.8%) had detectable GIP levels in stools. There was significant association between age and GIP in stools that revealed increasing dietary transgressions with advancing age (39.2% in subjects ≥13 years old) and with gender in certain age groups (60% in men ≥13 years old). No association was found between fecal GIP and dietary questionnaire or anti-tTG antibodies. However, association was detected between GIP and anti-DGP antibodies, although 46 of the 53 GIP stool-positive patients were negative for anti-DGP. Conclusions: Detection of gluten peptides in stools reveals limitations of traditional methods for monitoring GFD in celiac patients. The GIP ELISA enables direct and quantitative assessment of gluten exposure early after ingestion and could aid in the diagnosis and clinical management of nonresponsive CD and refractory CD. Trial registration number NCT02711397. PMID:27644734

  20. Results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.; Komine, Kuniaki; Matsumoto, Tomoyuki; Costello, J.F.

    1998-05-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed by the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed

  1. CAT SCRATCH DISEASE: RESULTS OF COMPLEMENT-FIXATION AND SKIN TESTS

    Science.gov (United States)

    Serologic and skin-testing data on a group of patients having cat scratch disease are presented to demonstrate a possible relationship to the psitt...indicate that the incidence of positive serologic reactions with the psitt-LGV group antigen is consistently higher in patients with cat scratch disease...patients, 2 of 5 did not respond with positive skin reactions when tested with cat scratch antigen, and at least 2 of the remaining 3 responded in a manner difficult to interpret.

  2. The PANDA facility and first test results

    International Nuclear Information System (INIS)

    Dreier, J.; Huggenberger, M.; Aubert, C.; Bandurski, T.; Fischer, O.; Healzer, J.; Lomperski, S.; Strassberger, H.J.; Varadi, G.; Yadigaroglu, G.

    1996-01-01

    The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (orig.) [de

  3. Superconducting solenoid model magnet test results

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; /Fermilab

    2006-08-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests.

  4. Superconducting solenoid model magnet test results

    International Nuclear Information System (INIS)

    Carcagno, R.; Dimarco, J.; Feher, S.; Ginsburg, C.M.; Hess, C.; Kashikhin, V.V.; Orris, D.F.; Pischalnikov, Y.; Sylvester, C.; Tartaglia, M.A.; Terechkine, I.; Tompkins, J.C.; Wokas, T.; Fermilab

    2006-01-01

    Superconducting solenoid magnets suitable for the room temperature front end of the Fermilab High Intensity Neutrino Source (formerly known as Proton Driver), an 8 GeV superconducting H- linac, have been designed and fabricated at Fermilab, and tested in the Fermilab Magnet Test Facility. We report here results of studies on the first model magnets in this program, including the mechanical properties during fabrication and testing in liquid helium at 4.2 K, quench performance, and magnetic field measurements. We also describe new test facility systems and instrumentation that have been developed to accomplish these tests

  5. Alternative filtration testing program: Pre-evaluation of test results

    International Nuclear Information System (INIS)

    Georgeton, G.K.; Poirier, M.R.

    1990-01-01

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing

  6. Alternative filtration testing program: Pre-evaluation of test results

    Energy Technology Data Exchange (ETDEWEB)

    Georgeton, G.K.; Poirier, M.R.

    1990-09-28

    Based on results of testing eight solids removal technologies and one pretreatment option, it is recommended that a centrifugal ultrafilter and polymeric ultrafilter undergo further testing as possible alternatives to the Norton Ceramic filters. Deep bed filtration should be considered as a third alternative, if a backwashable cartridge filter is shown to be inefficient in separate testing.

  7. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  8. Leishmania serology in the diagnosis of cutaneous leishmaniasis

    International Nuclear Information System (INIS)

    Mashood, A.H.; Malik, N.; Abbasi, S.

    2013-01-01

    Background: The gold standard to diagnose cutaneous leishmaniasis is histopathology, but there has always been a need of a rapid, reliable, cheap and convenient laboratory investigation. Serological tests fulfill the above criteria. Objective: The objective of the study was to determine the sensitivity and specificity of enzyme linked immunosorbent assay (ELISA) in detection of leishmania antibodies, in comparison with the histopathology. Place and duration of study: The study was conducted in Military Hospital Rawalpindi from 1st November 2010 to 30th June 2011. Patients and methods: The study population included the patients who were clinically diagnosed with cutaneous leishmaniasis. All of them were biopsied and serum was sent for leishmania serology. Results: A total of 47 patients were included. They were all adult males. The histopathology was positive in 31/47 patients (65.95%), while the leishmania serology was positive in 36/47 cases (76.59%). The sensitiuites was 74.19%, specificity was 18.75%, positive predictive value has 63.88%, negative predicative value was 27% and accuracy was 55%. Conclusion: In the light of sensitivity analysis, it may be concluded that leishmania serology has moderate sensitivity and low specificity; hence it is not a reliable test for cutaneous leishmaniasis. (author)

  9. BWR Full Integral Simulation Test (FIST). Phase I test results

    International Nuclear Information System (INIS)

    Hwang, W.S.; Alamgir, M.; Sutherland, W.A.

    1984-09-01

    A new full height BWR system simulator has been built under the Full-Integral-Simulation-Test (FIST) program to investigate the system responses to various transients. The test program consists of two test phases. This report provides a summary, discussions, highlights and conclusions of the FIST Phase I tests. Eight matrix tests were conducted in the FIST Phase I. These tests have investigated the large break, small break and steamline break LOCA's, as well as natural circulation and power transients. Results and governing phenomena of each test have been evaluated and discussed in detail in this report. One of the FIST program objectives is to assess the TRAC code by comparisons with test data. Two pretest predictions made with TRACB02 are presented and compared with test data in this report

  10. Development and Validation of a Serologic Test Panel for Detection of Powassan Virus Infection in U.S. Patients Residing in Regions Where Lyme Disease Is Endemic.

    Science.gov (United States)

    Thomm, Angela M; Schotthoefer, Anna M; Dupuis, Alan P; Kramer, Laura D; Frost, Holly M; Fritsche, Thomas R; Harrington, Yvette A; Knox, Konstance K; Kehl, Sue C

    2018-01-01

    Powassan virus (POWV) is an emerging tick-borne arbovirus presenting a public health threat in North America. POWV lineage II, also known as deer tick virus, is the strain of the virus most frequently found in Ixodes scapularis ticks and is implicated in most cases of POWV encephalitis in the United States. Currently, no commercial tests are available to detect POWV exposure in tick-borne disease (TBD) patients. We describe here the development and analytical validation of a serologic test panel to detect POWV infections. The panel uses an indirect enzyme immunoassay (EIA) to screen. EIA-positive samples reflex to a laboratory-developed, POWV-specific immunofluorescence assay (IFA). The analytical sensitivity of the test panel was 89%, and the limit of detection was a plaque reduction neutralization test (PRNT) titer of 1:20. The analytical specificity was 100% for the IgM assay and 65% for the IgG assay when heterologous-flavivirus-positive samples were tested. On samples collected from regions where Lyme disease is endemic, seroprevalence for POWV in TBD samples was 9.4% (10 of 106) versus 2% when tested with non-TBD samples (2 of 100, P = 0.034). No evidence of POWV infection was seen in samples collected from a region where Lyme disease was not endemic (0 of 22). This test panel provides a sensitive and specific platform for detecting a serologic response to POWV early in the course of infection when neutralizing antibodies may not be detectable. Combined with clinical history, the panel is an effective tool for identifying acute POWV infection. IMPORTANCE Approximately 100 cases of POWV disease were reported in the United States over the past 10 years. Most cases have occurred in the Northeast (52) and Great Lakes (45) regions (https://www.cdc.gov/powassan/statistics.html). The prevalence of POWV in ticks and mammals is increasing, and POWV poses an increasing threat in a greater geographical range. In areas of the Northeast and Midwest where Lyme disease is

  11. SULTAN test facility: Summary of recent results

    International Nuclear Information System (INIS)

    Stepanov, Boris; Bruzzone, Pierluigi; Sedlak, Kamil; Croari, Giancarlo

    2013-01-01

    The test campaigns of the ITER conductors in the SULTAN test facility re-started in December 2011 after three months break. The main focus of the activities is about the qualification tests of the Central Solenoid (CS) conductors, with three different samples for a total six variations of strand suppliers and cable layouts. In 2012, five Toroidal Field (TF) conductor samples have also been tested as part of the supplier and process qualification phase of the European, Korean, Chinese and Russian Federation Agencies. A summary of the test results for all the ITER samples tested in the last period is presented, including an updated statistics of the broad transition, the performance degradation and the impact of layout variations. The role of SULTAN test facility during the ITER construction is reviewed, and the load of work for the next three years is anticipated

  12. Production LHC HTS power lead test results

    CERN Document Server

    Tartaglia, M; Fehér, S; Huang, Y; Orris, D F; Pischalnikov, Y; Rabehl, Roger Jon; Sylvester, C D; Zbasnik, J

    2005-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under "standard" and "extreme" operating conditions, and the stability of performance across thermal cycles.

  13. Production LHC HTS power lead test results

    International Nuclear Information System (INIS)

    Tartaglia, M.A.; Carcagno, R.H.; Feher, S.; Huang, Y.; Orris, D.F.; Pischalnikov, Y.; Rabehl, R.J.; Sylvester, C.; Zbasnik, J.

    2004-01-01

    The Fermilab Magnet test facility has built and operated a test stand to characterize the performance of HTS power leads. We report here the results of production tests of 20 pairs of 7.5 kA HTS power leads manufactured by industry for installation in feed boxes for the LHC Interaction Region quadrupole strings. Included are discussions of the thermal, electrical, and quench characteristics under ''standard'' and ''extreme'' operating conditions, and the stability of performance across thermal cycles

  14. Comparison of PCR, culture, and serological tests for diagnosis of Mycoplasma pneumoniae respiratory tract infection in children

    NARCIS (Netherlands)

    Dorigo-Zetsma, J. W.; Zaat, S. A.; Wertheim-van Dillen, P. M.; Spanjaard, L.; Rijntjes, J.; van Waveren, G.; Jensen, J. S.; Angulo, A. F.; Dankert, J.

    1999-01-01

    For diagnosis of Mycoplasma pneumoniae infection we compared two rapid tests, PCR and the immunoglobulin M immunofluorescence assay (IgM IFA), with culture and the complement fixation test (CFT), in a prospective study among 92 children with respiratory tract infection and 74 controls. Based on

  15. SYBR green-based real-time reverse transcription-PCR for typing and subtyping of all hemagglutinin and neuraminidase genes of avian influenza viruses and comparison to standard serological subtyping tests

    Science.gov (United States)

    Tsukamoto, K.; Javier, P.C.; Shishido, M.; Noguchi, D.; Pearce, J.; Kang, H.-M.; Jeong, O.M.; Lee, Y.-J.; Nakanishi, K.; Ashizawa, T.

    2012-01-01

    Continuing outbreaks of H5N1 highly pathogenic (HP) avian influenza virus (AIV) infections of wild birds and poultry worldwide emphasize the need for global surveillance of wild birds. To support the future surveillance activities, we developed a SYBR green-based, real-time reverse transcriptase PCR (rRT-PCR) for detecting nucleoprotein (NP) genes and subtyping 16 hemagglutinin (HA) and 9 neuraminidase (NA) genes simultaneously. Primers were improved by focusing on Eurasian or North American lineage genes; the number of mixed-base positions per primer was set to five or fewer, and the concentration of each primer set was optimized empirically. Also, 30 cycles of amplification of 1:10 dilutions of cDNAs from cultured viruses effectively reduced minor cross- or nonspecific reactions. Under these conditions, 346 HA and 345 NA genes of 349 AIVs were detected, with average sensitivities of NP, HA, and NA genes of 10 1.5, 10 2.3, and 10 3.1 50% egg infective doses, respectively. Utility of rRT-PCR for subtyping AIVs was compared with that of current standard serological tests by using 104 recent migratory duck virus isolates. As a result, all HA genes and 99% of the NA genes were genetically subtyped, while only 45% of HA genes and 74% of NA genes were serologically subtyped. Additionally, direct subtyping of AIVs in fecal samples was possible by 40 cycles of amplification: approximately 70% of HA and NA genes of NP gene-positive samples were successfully subtyped. This validation study indicates that rRT-PCR with optimized primers and reaction conditions is a powerful tool for subtyping varied AIVs in clinical and cultured samples. Copyright ?? 2012, American Society for Microbiology. All Rights Reserved.

  16. Recent trends in the serologic diagnosis of syphilis.

    Science.gov (United States)

    Morshed, Muhammad G; Singh, Ameeta E

    2015-02-01

    Complexities in the diagnosis of syphilis continue to challenge clinicians. While direct tests (e.g., microscopy or PCR) are helpful in early syphilis, the mainstay of diagnosis remains serologic tests. The traditional algorithm using a nontreponemal test (NTT) followed by a treponemal test (TT) remains the standard in many parts of the world. More recently, the ability to automate the TT has led to the increasingly widespread use of reverse algorithms using treponemal enzyme immunoassays (EIAs). Rapid, point-of-care TTs are in widespread use in developing countries because of low cost, ease of use, and reasonable performance. However, none of the current diagnostic algorithms are able to distinguish current from previously treated infections. In addition, the reversal of traditional syphilis algorithms has led to uncertainty in the clinical management of patients. The interpretation of syphilis tests is further complicated by the lack of a reliable gold standard for syphilis diagnostics, and the newer tests can result in false-positive reactions similar to those seen with older tests. Little progress has been made in the area of serologic diagnostics for congenital syphilis, which requires assessment of maternal treatment and serologic response as well as clinical and laboratory investigation of the neonate for appropriate management. The diagnosis of neurosyphilis continues to require the collection of cerebrospinal fluid for a combination of NTT and TT, and, while newer treponemal EIAs look promising, more studies are needed to confirm their utility. This article reviews current tests and discusses current controversies in syphilis diagnosis, with a focus on serologic tests. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  17. Recent Trends in the Serologic Diagnosis of Syphilis

    Science.gov (United States)

    Singh, Ameeta E.

    2014-01-01

    Complexities in the diagnosis of syphilis continue to challenge clinicians. While direct tests (e.g., microscopy or PCR) are helpful in early syphilis, the mainstay of diagnosis remains serologic tests. The traditional algorithm using a nontreponemal test (NTT) followed by a treponemal test (TT) remains the standard in many parts of the world. More recently, the ability to automate the TT has led to the increasingly widespread use of reverse algorithms using treponemal enzyme immunoassays (EIAs). Rapid, point-of-care TTs are in widespread use in developing countries because of low cost, ease of use, and reasonable performance. However, none of the current diagnostic algorithms are able to distinguish current from previously treated infections. In addition, the reversal of traditional syphilis algorithms has led to uncertainty in the clinical management of patients. The interpretation of syphilis tests is further complicated by the lack of a reliable gold standard for syphilis diagnostics, and the newer tests can result in false-positive reactions similar to those seen with older tests. Little progress has been made in the area of serologic diagnostics for congenital syphilis, which requires assessment of maternal treatment and serologic response as well as clinical and laboratory investigation of the neonate for appropriate management. The diagnosis of neurosyphilis continues to require the collection of cerebrospinal fluid for a combination of NTT and TT, and, while newer treponemal EIAs look promising, more studies are needed to confirm their utility. This article reviews current tests and discusses current controversies in syphilis diagnosis, with a focus on serologic tests. PMID:25428245

  18. Establishment of the serologic testing algorithm for recent human immunodeficiency virus (HIV seroconversion (STARHS strategy in the city of São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Esper Georges Kallas

    Full Text Available Several strategies aim at characterizing the AIDS epidemic in different parts of the world. Among these, the identification of recent HIV-1 infections using the recently described serologic testing algorithm for recent human immunodeficiency virus (HIV seroconversion (STARHS strategy was employed in four testing sites of the City of São Paulo Public Health Department (CSPPHD. Those identified as recently infected were invited to participate in a prospective clinical and laboratory evaluation study. We describe the establishment of the patient identification network and the success in enrolling the participants, as well as their clinical and laboratory characteristics. From May to December 2002, 6,443 persons were tested for HIV in the four participating sites, of whom 384 (5.96% tested HIV-1 positive; 43 (11.2% of them were identified as recently infected. Twenty-two were successfully enrolled in the follow-up study, but three of them did not meet clinical and/or laboratory criteria for recent HIV-1 infection. After these exclusions, the laboratory findings revealed a median CD4+ T lymphocyte count of 585 cells/muL (inter-quartile range 25-75% [IQR], 372-754, a CD8+ T lymphocyte count of 886 cells/muL (IQR, 553-1098, a viral load of 11,000 HIV-RNA copies/mL (IQR, 3,650-78,150, log10 of 4.04 (IQR 3.56-4.88. The identification of recent HIV infections is an extremely valuable way to evaluate the spread of the virus in a given population, especially when cohort studies, considered the gold standard method to evaluate incidence, are not available. This work demonstrated that establishing a network to identify such patients is a feasible task, even considering the difficulties in a large, resource-limited country or city.

  19. Longitudinal study of dogs living in an area of Spain highly endemic for leishmaniasis by serologic analysis and the leishmanin skin test.

    Science.gov (United States)

    Solano-Gallego, Laia; Llull, Joan; Ramis, Antonio; Fernández-Bellon, Hugo; Rodríguez, Alhelí; Ferrer, Lluís; Alberola, Jordi

    2005-06-01

    The literature contains few longitudinal studies that have assessed areas endemic for canine leishmaniasis and over the same time interval Leishmania-specific cellular and humoral immunity in healthy dogs. Fourteen dogs, three mixed breed and 11 Ibizian hounds, living in an area of Spain that was highly endemic for leishmaniasis were followed-up over a three-year period by serologic analysis and the leishmanin skin test (LST). All but one of these dogs remained clinically healthy during the study period. Seroconversion was observed in four dogs. The three mixed breed dogs had a negative reaction in the LST in the first and third years. The general trend in the Ibizian hounds was an increase in the diameter of the LST reaction at both the 48- and 72-hour readings in the third year. This study demonstrates that in addition to an increase in Leishmania-specific humoral immune response in Ibizian hounds, a parallel increase in cellular immune response was observed.

  20. Performance of 2-D shear wave elastography in liver fibrosis assessment compared with serologic tests and transient elastography in clinical routine.

    Science.gov (United States)

    Bota, Simona; Paternostro, Rafael; Etschmaier, Alexandra; Schwarzer, Remy; Salzl, Petra; Mandorfer, Mattias; Kienbacher, Christian; Ferlitsch, Monika; Reiberger, Thomas; Trauner, Michael; Peck-Radosavljevic, Markus; Ferlitsch, Arnulf

    2015-09-01

    Liver stiffness values assessed with 2-D shear wave elastography (SWE), transient elastography (TE) and simple serologic tests were compared with respect to non-invasive assessment in a cohort of 127 consecutive patients with chronic liver diseases. The rate of reliable liver stiffness measurements was significantly higher with 2-D SWE than with TE: 99.2% versus 74.8%, p < 0.0001 (different reliability criteria used, according to current recommendations). In univariate analysis, liver stiffness measured with 2-D SWE correlated best with fibrosis stage estimated with TE (r = 0.699, p < 0.0001), followed by Forns score (r = 0.534, p < 0.0001) and King's score (r = 0.512, p < 0.0001). However, in multivariate analysis, only 2-D SWE-measured values remained correlated with fibrosis stage (p < 0.0001). The optimal 2-D SWE cutoff values for predicting significant fibrosis were 8.03 kPa for fibrosis stage ≥2 (area under the receiver operating characteristic curve = 0.832) and 13.1 kPa for fibrosis stage 4 (area under the receiver operating characteristic curve = 0.915), respectively. In conclusion, 2-D SWE can be used to obtain reliable liver stiffness measurements in almost all patients and performs very well in predicting the presence of liver cirrhosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  2. Antibody responses measured by various serologic tests in pigs orally inoculated with low numbers of Toxoplasma gondii oocysts

    DEFF Research Database (Denmark)

    Dubey, J. P.; Andrews, C.D.; Lind, Peter

    1996-01-01

    ) infective oocysts, and 6 pigs served as uninoculated controls. Blood (serum) samples were obtained at 1- to 3-week intervals until euthanasia. At necropsy, the brain, heart, and tongue of pigs were bioassayed in mice and cats for isolation of T gondii. Modified agglutination test (MAT), using whole, fixed...

  3. PRODUKSI ANTISERUM DAN KAJIAN SEROLOGI CHRYSANTHEMUM B CARLAVIRUS (CVB

    Directory of Open Access Journals (Sweden)

    I G.R.M. Temaja, G. Suastika S.H. Hidayat & U. Kartosuwondo .

    2011-11-01

    Full Text Available Antiserum production and serological assay of Chrysanthemum B Carlavirus (CVB. Virus identification based on spesific reaction between antigen and antibody  in serological assay has been widely applied as a tool for plant virus detection. The aims of this research is  to produce  antiserum of the CVB by  guinea pig immunization using  purified CVB of Cianjur isolate. The antiserum   was used further  for  the  serological test. Serological methods for detection of CVB were I-ELISA, TBIA, western blot and ISEM. The result showed that  guinea pig immunization  using 150 µg of purified virus was able to produce 10.75 ml of antiserum. The antiserum produced had high sensitivity for detection of CVB when examined by I-ELISA and TBIA. Besides its low cost, TBIA allows the samples to be blotted on the nitrocellulose membranes in the field and storage of the membranes for later processing in the laboratory. This feature makes it the metode of  choice for large-scale CVB surveying.

  4. Serological follow-up of infants born to mothers with positive syphilis serology - real-world experiences.

    Science.gov (United States)

    Wallace, Harriet E; Broomhall, Harriet M; Isitt, Catherine E; Miall, Lawrence S; Wilson, Janet D

    2016-11-01

    The 2008 UK syphilis guideline recommends infants born to women with any positive syphilis serology be followed up until both treponemal and nontreponemal tests are negative to exclude congenital syphilis, whereas Centers for Disease Control and Prevention guidelines recommend using only nontreponemal tests. Historically, we had low infant follow-up rates with no coherent pathways. We initiated a change in multidisciplinary team practice of infant testing for syphilis in 2011 and evaluated the results before and after by retrospective review of testing of infants born to women with positive syphilis serology between 2005 and 2012. A total of 28 infants' mothers were treated in pregnancy (termed 'high risk'); 26 had adequate treatment prior to pregnancy (termed 'low risk'). There was a significant increase in serological testing after 2011 compared with before (83% versus 48%; OR 5.07 [95% CI 1.22-22.77] p = 0.01) but mainly in low risk infants with no significant improvement in high risk infants who are the priority group. Using nontreponemal tests only in the infants would have reduced the tests required by at least 50%, allowing health resources to be concentrated on achieving adequate follow-up for those infants most at risk. © The Author(s) 2015.

  5. Reproducibility of the results in nondestructive testing

    International Nuclear Information System (INIS)

    Launay, J.P.; Chalaye, H.; Thomas, A.

    1980-10-01

    Pressure vessels must comply with very severe safety criteria. In order to ensure that the required quality is attained, non destructive tests are used and these have to be highly reliable: magnetoscopy and liquid penetration for surface examinations, radiography and ultrasonics for voluminal examinations. In the case of ultrasonic examinations, a study of parameters has been made and a statistical analysis of the results has made it possible to calculate the dispersion due to the testing equipment [fr

  6. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test acknow...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  7. Assessing the validity of an ELISA test for the serological diagnosis of human fascioliasis in different epidemiological situations.

    Science.gov (United States)

    Valero, M Adela; Periago, M Victoria; Pérez-Crespo, Ignacio; Rodríguez, Esperanza; Perteguer, M Jesús; Gárate, Teresa; González-Barberá, Eva M; Mas-Coma, Santiago

    2012-05-01

    To improve the diagnosis of human fascioliasis caused by Fasciola hepatica and Fasciola gigantica, we evaluated the diagnostic accuracy of an enzyme-linked immunosorbent assay (ELISA), with Fasciola antigen from the adult liver fluke, for the detection of IgG against fascioliasis in human sera. The sera of 54 fascioliasis cases, originating from three endemic areas, were used in this evaluation: (i) a hyperendemic F. hepatica area where humans usually shed a great number of parasite eggs in faeces (11 sera); (ii) an epidemic F. hepatica area where humans usually shed small amounts of parasite eggs (24 sera) and (iii) an overlap area of both Fasciola species and where human shedding of parasite eggs in faeces is usually scarce or non-existent (19 sera). One hundred and sixty-eight patients with other parasitic infections and 89 healthy controls were also analysed. The respective sensitivity and specificity of this assay were 95.3% (95% confidence intervals, 82.9-99.2%) and 95.7% (95% confidence intervals, 92.3-97.5%). No correlation between egg output and the OD450 values of the F. hepatica IgG ELISA test was observed. This test could be used both as an individual serodiagnostic test for human fascioliasis when backed up by a compatible clinical history together with a second diagnostic technique for other cross-reactive helminth infections, and in large-scale epidemiological studies of human fascioliasis worldwide. © 2012 Blackwell Publishing Ltd.

  8. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von

    2000-01-01

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  9. Radionuclide-labelled antigens in serological epidemiology

    International Nuclear Information System (INIS)

    Felsenfeld, O.; Parrott, M.W.

    1977-01-01

    The feasibility of tests using radionuclide-labelled antigens in serological surveys was studied, with particular attention to the likely availability of facilities and personnel in the tropics and arctics, where measurements may be disturbed by climatic influences. The methodology required was to be simple, rapid and suitable for examining large numbers of sera, as for epidemological surveys. In the introduction, limitations of labelled antigen tests are discussed, the choice of radionuclide and measurement methods, test procedures and evaluation of results. Collection, preservation and shipment of speciments (serum, faeces, cerebrospinal fluid, sputum, etc.) are described. Experiments with bacteria and bacterial toxins (Enterobacteriaceae, vibrios, staphylococci, meningococci, etc.), with protozoa and metazoa (Entamoeba hystolytica, Schistosoma mansoni, Trypanosoma cruzi, Plasmodia and other parasites), with viruses (vaccinia, adeno-, polio-, and influenza viruses, etc.), and with fungi are discussed

  10. Test Results of PBMR Fuel Spheres

    International Nuclear Information System (INIS)

    Koshcheev, Konstantin; Diakov, Alexander; Beltyukov, Igor; Barybin, Andrey; Chernetsov, Mikhail

    2014-01-01

    Results of pre-irradiation testing of fuel spheres (FS) and coated particles (CP) manufactured by PBMR SOC (Republic of South Africa) are described. The stable high quality level of major characteristics (dimensions, CP coating structure, uranium-235 contamination of the FS matrix graphite and the outer PyC layer of the CP coating) are shown. Results of a methodical irradiation test of two FS in helium and neon medium at temperatures of 800 to 1300 °C with simultaneous determination of release-to-birth ratios for major gaseous fission products (GFP) are described. (author)

  11. Serologic detection of coccidioidomycosis antibodies in northeast Brazil.

    Science.gov (United States)

    Cordeiro, Rossana de Aguiar; Fechine, Maria Auxiliadora Bezerra; Brilhante, Raimunda Sâmia Nogueira; Rocha, Marcos Fábio Gadelha; da Costa, Ana Karoline Freire; Nagao, Maria Aparecida Tiemi Dias; de Camargo, Zoilo Pires; Sidrim, José Júlio Costa

    2009-04-01

    Coccidioidomycosis is a systemic infection caused by Coccidioides spp. The disease is endemic in Brazil but its incidence is underreported as it is not a notifiable disease. This article presents the results of a serologic survey carried out with 229 volunteers in northeast Brazil by the immunodiffusion (ID) test with commercial Coccidioides spp. antigens. The commercial ID test detected 15 individuals without clinical diagnosis of the disease and two individuals in treatment for coccidioidomycosis. Regarding the epidemiological data, most of the positive individuals were male, between 18 and 65 years of age and were engaged in armadillo hunting. Three women who had never participated in armadillo hunts also displayed positive results for coccidioidal antibodies. Besides armadillo hunts, exposure to environmental dust in endemic areas may account for the serologic response detected in the study. The data from this study suggest the importance of performing epidemiological surveys for coccidioidomycosis in order to understand the prevalence of this disease in Brazil.

  12. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  13. Comparative analysis of the intracerebral mouse protection test and serological method for potency assays of pertussis component in DTP vaccine

    Directory of Open Access Journals (Sweden)

    Denise Cristina Souza Matos

    2012-06-01

    Full Text Available The aim of this study was to compare the PSPT standardized in-house as an alternative to MPT for potency assays of pertussis component. Statistical analyses have showed similar pertussis potency values when PSPT was compared to MPT. Significant correlation between the potency results obtained by in vivo and in vitro assays was also been observed. Results by PSPT have demonstrated reproducibility and accuracy for potency pertussis control and this approach has been considered promising for use at least during the steps of production.

  14. ALICE TRD results from prototype tests

    CERN Document Server

    Andronic, A; Blume, C; Braun-Munzinger, P; Bucher, D; Catanescu, G; Ciobanu, M; Daues, H W; Devismes, A; Finck, C; Herrmann, N; Lister, T A; Mahmoud, Tariq; Peitzmann, Thomas; Petrovici, M; Reygers, K; Santo, R; Schicker, R; Sedykha, S; Simon, R S; Stachel, J; Stelzer, H; Wessels, J P; Winkelmann, O; Windelband, B; Xu, C

    2002-01-01

    We present results from tests of a prototype of the TRD for the ALICE experiment at LHC. We investigate the performance-of different radiator types, composed of foils, fibres and foams. The pion rejection performance for different methods of analysis over a momentum range from 0.7 to 2 GeV/c is presented. (8 refs).

  15. SLD liquid argon calorimeter prototype test results

    International Nuclear Information System (INIS)

    Dubois, R.; Eigen, G.; Au, Y.

    1985-10-01

    The results of the SLD test beam program for the selection of a calorimeter radiator composition within a liquid argon system are described, with emphasis on the study of the use of uranium to obtain equalization of pion and electron responses

  16. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  17. Ball Aerospace SBMD Coating Test Results

    Science.gov (United States)

    Brown, Robert; Lightsey, Paul; Russell, J. Kevin (Technical Monitor)

    2002-01-01

    The Sub-scale Beryllium Mirror Demonstrator that was successfully tested to demonstrate cryogenic figuring of a bare mirror has been coated with a protected gold reflective surface and retested at cryogenic temperatures. Results showing less than 9 nm rms surface distortion attributable to the added coating are presented.

  18. 42 CFR 493.835 - Standard; Syphilis serology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Syphilis serology. 493.835 Section 493.835 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... These Tests § 493.835 Standard; Syphilis serology. (a) Failure to attain an overall testing event score...

  19. Use of serologic tests to predict resistance to Canine distemper virus-induced disease in vaccinated dogs.

    Science.gov (United States)

    Jensen, Wayne A; Totten, Janet S; Lappin, Michael R; Schultz, Ronald D

    2015-09-01

    The objective of the current study was to determine whether detection of Canine distemper virus (CDV)-specific serum antibodies correlates with resistance to challenge with virulent virus. Virus neutralization (VN) assay results were compared with resistance to viral challenge in 2 unvaccinated Beagle puppies, 9 unvaccinated Beagle dogs (4.4-7.2 years of age), and 9 vaccinated Beagle dogs (3.7-4.7 years of age). Eight of 9 (89%) unvaccinated adult dogs exhibited clinical signs after virus challenge, and 1 (13%) dog died. As compared to adult dogs, the 2 unvaccinated puppies developed more severe clinical signs and either died or were euthanized after challenge. In contrast, no clinical signs were detected after challenge of the 9 adult vaccinated dogs with post-vaccination intervals of up to 4.4 years. In vaccinated dogs, the positive and negative predictive values of VN assay results for resistance to challenge were 100% and 0%, respectively. Results indicate that dogs vaccinated with modified live CDV can be protected from challenge for ≤4.4 years postvaccination and that detection of virus-specific antibodies is predictive of whether dogs are resistant to challenge with virulent virus. Results also indicate that CDV infection in unvaccinated dogs results in age-dependent morbidity and mortality. Knowledge of age-dependent morbidity and mortality, duration of vaccine-induced immunity, and the positive and negative predictive values of detection of virus-specific serum antibodies are useful in development of rational booster vaccination intervals for the prevention of CDV-mediated disease in adult dogs. © 2015 The Author(s).

  20. Serological diagnosis of syphilis: a comparison of different diagnostic methods.

    Science.gov (United States)

    Simčič, Saša; Potočnik, Marko

    2015-01-01

    Serological tests' limitations in syphilis diagnosis as well as numerous test interpretations mean that patients with discordant serology results can present diagnostic and treatment challenges for clinicians. We analyzed three common diagnostic algorithms for detecting suspected syphilis in high-prevalence populations in Slovenia. The prospective study included a total of 437 clinical serum samples from adults throughout Slovenia tested with Rapid Plasma Reagin (RPR), Treponema pallidum hemagglutination (TPHA), and an automated chemiluminescence immunoassay (CIA) according to the manufacturer's instructions. In addition to percent agreement, kappa coefficients were calculated as a secondary measure of agreement between the three algorithms. Overall, of 183 subjects that had seroreactive results, 180 were seroreactive in both the reverse sequence and the European Centre for Disease Prevention and Control (ECDC) algorithm. The traditional algorithm had a missed serodiagnosis rate of 30.0%, the overall percent agreement between the traditional and the reverse algorithm (or the ECDC algorithm) was 87.6%, and the kappa value was 0.733. However, the reverse and ECDC algorithm failed to detect three subjects with positive serodiagnosis determined by additional confirmative treponemal assays. Our results supported the ECDC algorithm in the serodiagnosis of syphilis in high-prevalence populations and the use of nontreponemal serology to monitor the response to treatment.

  1. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  2. Serological response of cattle to Brucella allergen after repeated intradermal applications of this allergen

    NARCIS (Netherlands)

    Muskens, J.A.M.; Bercovich, Z.; Damen, C.P.R.M.

    1996-01-01

    A study was conducted to determine whether an allergen that has been prepared from a mucoid strain of Brucella abortus triggers a serum antibody response that interferes with the interpretation of serologic tests results. Fifteen cattle seronegative for Brucella antigen were tested with the SDTH

  3. Serological pregnancy diagnosis of syphilis in pregnancy ...

    African Journals Online (AJOL)

    S.N. Naicker, J. Moodley, A. Van Middelkoop, R.C. Cooper. Abstract. Three different serological screening tests for syphilis were performed at the 'booking' visit of 500 antenatal patients at the King Edward VIII Hospital, Durban. The prevalence of ... The TPHA test is therefore advocated for screening patients for syphilis.

  4. Boeing's STAR-FODB test results

    Science.gov (United States)

    Fritz, Martin E.; de la Chapelle, Michael; Van Ausdal, Arthur W.

    1995-05-01

    Boeing has successfully concluded a 2 1/2 year, two phase developmental contract for the STAR-Fiber Optic Data Bus (FODB) that is intended for future space-based applications. The first phase included system analysis, trade studies, behavior modeling, and architecture and protocal selection. During this phase we selected AS4074 Linear Token Passing Bus (LTPB) protocol operating at 200 Mbps, along with the passive, star-coupled fiber media. The second phase involved design, build, integration, and performance and environmental test of brassboard hardware. The resulting brassboard hardware successfully passed performance testing, providing 200 Mbps operation with a 32 X 32 star-coupled medium. This hardware is suitable for a spaceflight experiment to validate ground testing and analysis and to demonstrate performace in the intended environment. The fiber bus interface unit (FBIU) is a multichip module containing transceiver, protocol, and data formatting chips, buffer memory, and a station management controller. The FBIU has been designed for low power, high reliability, and radiation tolerance. Nine FBIUs were built and integrated with the fiber optic physical layer consisting of the fiber cable plant (FCP) and star coupler assembly (SCA). Performance and environmental testing, including radiation exposure, was performed on selected FBIUs and the physical layer. The integrated system was demonstrated with a full motion color video image transfer across the bus while simultaneously performing utility functions with a fiber bus control module (FBCM) over a telemetry and control (T&C) bus, in this case AS1773.

  5. Results from the CLIC Test Facility

    CERN Document Server

    Braun, H; Bossart, Rudolf; Chautard, F; Corsini, R; Delahaye, J P; Godot, J C; Hutchins, S; Kamber, I; Madsen, J H B; Rinolfi, Louis; Rossat, G; Schreiber, S; Suberlucq, Guy; Thorndahl, L; Wilson, Ian H; Wuensch, Walter

    1996-01-01

    In order to study the principle of the Compact Linear Collider (CLIC) based on the Two Beam Acceleration (TBA) scheme at high frequency, a CLIC Test Facility (CTF) has been set-up at CERN. After four years of successful running, the experimental programme is now fully completed and all its objectives reached, particularly the generation of a high intensity drive beam with short bunches by a photo-injector, the production of 30 GHz RF power and the acceleration of a probe beam by 30 GHz structures. A summary of the CTF results and their impact on linear collider design is given. This covers 30 GHz high power testing, study of intense, short single bunches; as well as RF-Gun, photocathode and beam diagnostic developments. A second phase of the test facility (CTF2) is presently being installed to demonstrate the feasibility of the TBA scheme by constructing a fully engineered, 10 m long, test section very similar to the CLIC drive and main linacs, producing up to 480 MW of peak RF power at 30 GHz and acceleratin...

  6. 21 CFR 866.3235 - Epstein-Barr virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3235 Epstein-Barr... consist of antigens and antisera used in serological tests to identify antibodies to Epstein-Barr virus in...

  7. The Benchmark Test Results of QNX RTOS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Yeol; Lee, Young Jun; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

  8. The Benchmark Test Results of QNX RTOS

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon

    2010-01-01

    A Real-Time Operating System(RTOS) is an Operating System(OS) intended for real-time applications. Benchmarking is a point of reference by which something can be measured. The QNX is a Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available Personal Computer(PC) for applications such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS). The ELMSYS PC Hardware is being qualified by KTL(Korea Testing Lab.) for use as a Cabinet Operator Module(COM). The QNX RTOS is being dedicated by Korea Atomic Energy Research Institute (KAERI). This paper describes the outline and benchmarking test results on Context Switching, Message Passing, Synchronization and Deadline Violation of QNX RTOS under the ELMSYS PC platform

  9. Synthesis of low cycle fatigue test results

    International Nuclear Information System (INIS)

    Andrews, R.M.

    1990-01-01

    Axial strain controlled cycle fatigue tests were carried out on type 316 stainless steel parent metal, vacuum and non-vacuum electron beams welds, submerged arc welds and gas shielded metal arc welds. Testing covered total strains in the range 0.6% to 2%, and was at room temperature and 550 0 C. Parent metal and the electron beam welds showed rapid cyclic hardening, while arc welds showed little hardening. The weld metal cyclic stress-strain response was above that obtained for the parent metal, although below data obtained by other workers for similar parent materials. Weld metal endurances were above the ASME N47 continuous cycling design line at both temperatures, and comparable with parent metal data. However, the weld metal data approached the design line at low strain ranges (around 0.5%). Endurances were predicted from crack growth rates estimated from striation spacings, giving acceptable results except for the gas shielded metal arc weldments. (author)

  10. Results from the STAR TPC system test

    International Nuclear Information System (INIS)

    Betts, W.

    1996-01-01

    A system test of various components of the Solenoidal Tracker at RHIC (STAR) detector, operating in concern, has recently come on-line. Communication between a major sub-detector, a sector of the Time Projection Chamber (TPC), and the trigger, data acquisition and slow controls systems has been established, enabling data from cosmic ray muons to be collected. First results from an analysis of the TPC data are presented. These include measurements of system noise, electronic parameters such as amplifier gains and pedestal values, and tracking resolution for cosmic ray muons and laser induced ionization tracks. A discussion on the experience gained in integrating the different components for the system test is also given

  11. Evaluation of ring tensile test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Anantharaman, S.; Balakrishnan, K.S.; Sivaramakrish, K.S.

    1990-01-01

    Ring specimens of 5-mm width cut from Zircaloy-2 cladding of reactor operated fuel elements that had experienced 5000 to 15,000 MWD/T of fuel burnup were subjected to ring tensile testing. The true stress-true strain data points up to the onset of necking from the individual load-elongation curves of these specimens were used as input data in Voce's equation. The results reveal that the uniform elongation (UE) values generated using Voce's equation were within (UE-2)% of the experimental percent uniform elongation (UE%). The corresponding ultimate tensile strength values were within ±1%. The uncertainty inherently associated in the determination of gauge length introduces extraneous deformation in the rings tested. Previous results had shown that a 14% increase in cladding diameter caused the gauge length to increase by 40%. To simulate the contribution of extraneous deformation due to an increase in cladding diameter, an analysis of the variation of the tensile parameters (uniform elongation and ultimate tensile strength) due to increase in the gauge length in the range of 10 to 40% was carried out. The results are discussed

  12. Dual color radiometer imagery and test results

    International Nuclear Information System (INIS)

    Silver, A.; Carlen, F.; Link, D.; Zegel, F.

    1989-01-01

    This paper presents a review of the technical characteristics of the Dual Color Radiometer and recent data and test results. The Dual Color Radiometer is a state-of-the-art device that provides simultaneous pixel to pixel registered thermal imagery in both the 3 to 5 and 8 to 12 micron regions. The device is unique in terms of its spatial and temperature resolution of less than 0.10 degrees C temperature and 0.10 milliradian spatial resolution. In addition, the device is tailored for use by the Automatic Target Recognizer (ATR) community

  13. Arc melter demonstration baseline test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O'Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process

  14. AOF: standalone test results of GALACSI

    Science.gov (United States)

    La Penna, P.; Aller Carpentier, E.; Argomedo, J.; Arsenault, R.; Conzelmann, R. D.; Delabre, B.; Donaldson, R.; Gago, F.; Gutierrez-Cheetam, P.; Hubin, N.; Jolley, P.; Kiekebusch, M.; Kirchbauer, J. P.; Klein, B.; Kolb, J.; Kuntschner, H.; Le Louarn, M.; Lizon, J.-L.; Madec, P.-Y.; Manescau, A.; Mehrgan, L.; Oberti, S.; Quentin, J.; Sedghi, B.; Ströbele, S.; Suárez Valles, M.; Soenke, C.; Tordo, S.; Vernet, J.

    2016-07-01

    GALACSI is the Adaptive Optics (AO) module that will serve the MUSE Integral Field Spectrograph. In Wide Field Mode it will enhance the collected energy in a 0.2"×0.2" pixel by a factor 2 at 750 nm over a Field of View (FoV) of 1'×1' using the Ground Layer AO (GLAO) technique. In Narrow Field Mode, it will provide a Strehl Ratio of 5% (goal 10%) at 650 nm, but in a smaller FoV (7.5"×7.5" FoV), using Laser Tomography AO (LTAO). Before being ready for shipping to Paranal, the system has gone through an extensive testing phase in Europe, first in standalone mode and then in closed loop with the DSM in Europe. After outlining the technical features of the system, we describe here the first part of that testing phase and the integration with the AOF ASSIST (Adaptive Secondary Setup and Instrument Stimulator) testbench, including a specific adapter for the IRLOS truth sensor. The procedures for the standalone verification of the main system performances are outlined, and the results of the internal functional tests of GALACSI after full integration and alignment on ASSIST are presented.

  15. Partial-array test results in IFSMTF

    International Nuclear Information System (INIS)

    Lue, J.W.; Dresner, L.; Koizumi, K.; Lubell, M.S.; Luton, J.N.; Shen, S.S.; Zahn, G.R.; Zichy, J.A.

    1985-01-01

    Preliminary performance tests of two large superconducting magnets have been carried out in the International Fusion Superconducting Magnet Test Facility (IFSMTF). Each of the Japanese (JA) and General Dynamics/Convair (GD) coils was operated up to its full design current of 10.2 kA with the other serving as an adjacent background coil at 40% of design current. Cryostatic stability was demonstrated for both coils by noting recovery from a full half-turn (5 m) driven normal. A new pick-up coil compensation scheme was successfully used for the quench detection system. Each coil remained superconducting when the other was dumped. Unique instrumentation was used to measure changes in bore dimensions and displacement of the winding from the coil case. Agreement between structural analysis and measurement of bore dimension changes resulting from magnetic loads is good. The Swiss (CH) coil underwent only a cryogenic test. The forced cooling worked well and an inlet temperature of 3.8 K was demonstrated

  16. Updated Results of Ultrasonic Transducer Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua; Palmer, Joe [Idaho National Laboratory, P.O. Box 1625, MS 4112, Idaho Falls, ID, 38415-3840 (United States); Ramuhalli, Pradeep; Keller, Paul; Montgomery, Robert [Pacific Northwest National Laboratory, 902 Battelle Blvd. Richland, WA, 99354 (United States); Chien, Hual-Te [Argonne National Laboratory, 9700 S. Cass Avenue Argonne, IL, 60439 (United States); Tittmann, Bernhard; Reinhardt, Brian [Pennsylvania State University, 212 Earth and Engr. Sciences Building, University Park, PA, 16802 (United States); Kohse, Gordon [Massachusetts Institute of Technology, 77 Massachusetts Ave. Cambridge, MA 02139 (United States); Rempe, Joy [Rempe and Associates, LLC, 360 Stillwater, Idaho Falls, ID 83404 (United States); Villard, J.F. [Commissariat a l' energie atomique et aux energies alternatives, Centre d' etudes de Cadarache, 13108 Saint-Paul-lez-Durance (France)

    2015-07-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10{sup 21} n/cm{sup 2}. A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET-ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation. (authors)

  17. Synovial aspiration and serological testing in two-stage revision arthroplasty for prosthetic joint infection: evaluation before reconstruction with a mean follow-up of twenty seven months.

    Science.gov (United States)

    Mühlhofer, Heinrich M L; Knebel, C; Pohlig, Florian; Feihl, Susanne; Harrasser, Norbert; Schauwecker, Johannes; von Eisenhart-Rothe, Rüdiger

    2018-02-01

    The two-stage revision protocol is the gold standard for controlling and treating low-grade prosthetic joint infections of total hip and total knee arthroplasty. The antibiotic pause for diagnostic reasons before reconstruction (stage two) is discussed in relation to the persistence of the infection and the development of resistant bacterial strains. Serological markers and a synovial analysis are commonly used to exclude the persistence of infection. Therefore, we asked (1) is the serological testing of C-reactive protein and leucocytes a valuable tool to predict a persistence of infection? and (2) what is the role of synovial aspiration of Plymethylmethacrylat (PMMA) spacers in hip and knee joints? One hundred twelve patients who were MSIS criteria-positive for a prosthetic joint infection were studied, including 45 total hip arthroplasties (THA) and 67 total knee artrhoplasties (TKA) patients. All patients were treated with a two-stage-protocol using a mobile PMMA spacer after a 14-day antibiotic-free interval, during which we measured serological markers (C-reactive protein and leucocytes) and performed synovial aspiration (white blood cell count, polymorphonuclear cell percentage, and microbiological culture) in these patients and compared the results with those of their long-term-follow-up (mean follow-up 27 months, range 24-36 months). Of the 112 patients, 89 patients (79.5%; 95% CI 72-86.9) exhibited infection control after a two-stage exchange, and we detected most methicillin-resistant, coagulase-negative Staphylococci (CoNS) in cases of a persistent infection. The mean sensitivity of serum C-reactive protein in the patients was 0.43 (range 0.23-0.64), and the mean specificity was 0.73 (range 0.64-0.82). For serum leucocytes, the mean sensitivity was 0.09 (range 0-0.29), and the mean specificity was 0.81 (range 0.7-0.92). The mean sensitivity for the WBC count in the synovial fluid (PMMA spacer aspiration) was 0.1 (range 0-0.29), and the mean

  18. Results from the Cooler and Lead Tests

    International Nuclear Information System (INIS)

    Green, Michael A.

    2010-01-01

    The report presents the results of testing MICE spectrometer magnet current leads on a test apparatus that combines both the copper leads and the high temperature superconducting (HTS) leads with a single Cryomech PT415 cooler and liquid helium tank. The current is carried through the copper leads from 300 K to the top of the HTS leads. The current is then carried through the HTS leads to a feed-through from the vacuum space to the inside of a liquid helium tank. The experiment allows one to measure the performance of both cooler stages along with the performance of the leads. While the leads were powered we measured the voltage drops through the copper leads, through the HTS leads, through spliced to the feed-through, through the feed-through and through the low-temperature superconducting loop that connects one lead to the other. Measurements were made using the leads that were used in spectrometer magnet 1A and spectrometer magnet 2A. These are the same leads that were used for Superbend and Venus magnets at LBNL. The IL/A for these leads was 5.2 x 10 6 m -1 . The leads turned out to be too long. The same measurements were made using the leads that were installed in magnet 2B. The magnet 2B leads had an IL/A of 3.3 x 10 6 A m -1 . This report discusses the cooler performance and the measured electrical performance of the lead circuit that contains the copper leads and the superconducting leads. All of the HTS leads that were installed in magnet 2B were current tested using this apparatus.

  19. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  20. Field Lysimeter Test Facility: Second year (FY 1989) test results

    International Nuclear Information System (INIS)

    Campbell, M.D.; Gee, G.W.; Kanyid, M.J.; Rockhold, M.L.

    1990-04-01

    The Record of Decision associated with the Hanford Defense Waste Environmental Impact Statement (53 FR 12449-53) commits to an evaluation of the use of protective barriers placed over near-surface wastes. The barrier must protect against wind and water erosion and limit plant and animal intrusion and infiltration of water. Successful conclusion of this program will yield the necessary protective barrier design for near-surface waste isolation. This report presents results from the second year of tests at the FLTF. The primary objective of testing protective barriers at the FLTF was to measure the water budgets within the various barriers and assess the effectiveness of their designs in limiting water intrusion into the zone beneath each barrier. Information obtained from these measurements is intended for use in refining barrier designs. Four elements of water budget were measured during the year: precipitation, evaporation, storage, and drainage. Run-off, which is a fifth element of a complete water budget, was made negligible by a lip on the lysimeters that protrudes 5 cm above the soil surface to prevent run-off. A secondary objective of testing protective barriers at the FLTF was to refine procedures and equipment to support data collection for verification of the computer model needed for long-term projections of barrier performance. 6 refs

  1. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  2. Use of pre-travel vaccine-preventable disease serology as a screening tool to identify patients in need of pre-travel vaccination: a retrospective audit.

    Science.gov (United States)

    Turner, David P; McGuinness, Sarah L; Cohen, Jonathan; Waring, Lynette J; Leder, Karin

    2017-05-01

    Vaccination is a safe and effective public health intervention that not only protects individual travellers from vaccine-preventable diseases (VPDs), but prevents them from becoming a source of disease in their destination and on their return. Obtaining an accurate vaccination history from travellers during a pre-travel review can be difficult; serology may be used to identify patients who are non-immune to specific diseases in order to guide vaccination requirements. Clinically relevant data about the usefulness of serology in this setting are lacking. We performed a retrospective audit of pre-travel VPD serology requested by practitioners of a busy community-based travel clinic. All serological results for measles, mumps, rubella, varicella zoster virus, hepatitis A and B requested over a 5-year period were extracted and analysed. Results were stratified by gender and year of birth and compared using Stata. Four thousand four hundred and fifty-one serological assays from 1445 individual were assessed. Overall, 47% of patients tested had at least one negative serological result. High rates of seropositivity for measles, mumps and rubella were seen in those born prior to 1966 but >10% of travellers born after 1966 lacked serological evidence of protection against these diseases. Hepatitis A and B serological results revealed broadly lower rates of immunity in our community likely reflecting the absence of these vaccines from historical vaccine protocols. Serology can be a useful tool in the identification of non-immune travellers to enable targeted vaccination prior to travel. We recommend that travel health clinicians assess patients' vaccination and infection histories, and strongly consider serology or vaccination where there is doubt about immunity. This will help protect the traveller and prevent importation of disease into destination or home communities. © International Society of Travel Medicine, 2017. Published by Oxford University Press. All rights

  3. Serological diagnosis of avian influenza in poultry

    DEFF Research Database (Denmark)

    Comin, Arianna; Toft, Nils; Stegeman, Arjan

    2013-01-01

    Background The serological diagnosis of avian influenza (AI) can be performed using different methods, yet the haemagglutination inhibition (HI) test is considered the gold standard' for AI antibody subtyping. Although alternative diagnostic assays have been developed, in most cases, their accuracy...

  4. Full length prototype SSC dipole test results

    International Nuclear Information System (INIS)

    Strait, J.; Brown, B.C.; Carson, J.

    1987-01-01

    Results are presented from tests of the first full length prototype SSC dipole magnet. The cryogenic behavior of the magnet during a slow cooldown to 4.5K and a slow warmup to room temperature has been measured. Magnetic field quality was measured at currents up to 2000 A. Averaged over the body field all harmonics with the exception of b 2 and b 8 are at or within the tolerances specified by the SSC Central Design Group. (The values of b 2 and b 8 result from known design and construction defects which will be be corrected in later magnets.) Using an NMR probe the average body field strength is measured to be 10.283 G/A with point to point variations on the order of one part in 1000. Data are presented on quench behavior of the magnet up to 3500 A (approximately 55% of full field) including longitudinal and transverse velocities for the first 250 msec of the quench

  5. Summary of CPAS EDU Testing Analysis Results

    Science.gov (United States)

    Romero, Leah M.; Bledsoe, Kristin J.; Davidson, John.; Engert, Meagan E.; Fraire, Usbaldo, Jr.; Galaviz, Fernando S.; Galvin, Patrick J.; Ray, Eric S.; Varela, Jose

    2015-01-01

    The Orion program's Capsule Parachute Assembly System (CPAS) project is currently conducting its third generation of testing, the Engineering Development Unit (EDU) series. This series utilizes two test articles, a dart-shaped Parachute Compartment Drop Test Vehicle (PCDTV) and capsule-shaped Parachute Test Vehicle (PTV), both of which include a full size, flight-like parachute system and require a pallet delivery system for aircraft extraction. To date, 15 tests have been completed, including six with PCDTVs and nine with PTVs. Two of the PTV tests included the Forward Bay Cover (FBC) provided by Lockheed Martin. Advancements in modeling techniques applicable to parachute fly-out, vehicle rate of descent, torque, and load train, also occurred during the EDU testing series. An upgrade from a composite to an independent parachute simulation allowed parachute modeling at a higher level of fidelity than during previous generations. The complexity of separating the test vehicles from their pallet delivery systems necessitated the use the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulator for modeling mated vehicle aircraft extraction and separation. This paper gives an overview of each EDU test and summarizes the development of CPAS analysis tools and techniques during EDU testing.

  6. Development of a virus neutralisation test to detect antibodies against Schmallenberg virus and serological results in suspect and infected herds

    NARCIS (Netherlands)

    Loeffen, W.L.A.; Quak, J.; Boer-Luijtze, de E.A.; Hulst, M.M.; Poel, van der W.H.M.; Bouwstra, R.J.; Maas, H.A.

    2012-01-01

    Background: At the end of 2011, a new orthobunyavirus, tentatively named Schmallenberg virus (SBV), was discovered in Germany. This virus has since been associated with clinical signs of decreased milk production, watery diarrhoea and fever in dairy cows, and subsequently also with congenital

  7. Initial Burn Pan (JMTF) Testing Results

    Science.gov (United States)

    2016-03-01

    burn pan and one located high on the Ex-USS Shadwell. There were also a number of GoPro cameras (3-4) that were positioned to observe specific...locations around the test area. A remote control drone equipped with a GoPro camera was also used to video the third test. All recorded video and still

  8. Evaluation of a serological Salmonella Mix-ELISA for poultry used in a national surveillance programme

    DEFF Research Database (Denmark)

    Feld, Niels Christian; Ekeroth, Lars; Gradel, K.O.

    2000-01-01

    by Mix-ELISA and by faecal culture, and in case of a positive result in either of these a repeated, serological testing was performed, and 60 animals were organ-cultured. If one of these samplings was positive, the flock was declared salmonella infected. In a period of 3 months, 35 flocks were found......A Mix-ELISA using lipopolysaccharide antigens from Salmonella enterica serotype Enteritidis and Typhimurium? was evaluated using samples collected over time in the Danish salmonella surveillance programme for poultry. Serological samples (n = 42813) taken from broiler-breeder flocks after a year...

  9. Supercritical CO2 test loop operation and first test results

    International Nuclear Information System (INIS)

    Wright, Steven A.; Pickard, Paul S.

    2009-01-01

    The DOE Office of Nuclear Energy is investigating advanced Brayton cycles for use with next generation nuclear power plants. The focus of this work is on the supercritical CO 2 Brayton cycle which has the potential for high efficiency, and for reduced capital costs due to very compact turbomachinery. Sandia has fabricated and is operating a supercritical CO 2 (S-CO 2 ) test loop to investigate the key technology issues associated with this cycle. This loop is part of a multi-year phased development program to develop a megawatt (MW) class closed S-CO 2 Brayton cycle to demonstrate the applicability of this cycle for DOE Gen-IV program. The current loop has been configured as both a compression loop and as simple heated but unrecuperated Brayton cycle. A second split-flow or re-compression Brayton cycle is currently under development that will use approximately 1 MW of heat to run the Brayton cycle. Early configurations of this split-flow Brayton cycle will be operational later this fiscal year. The key issues for this cycle include the fundamental issues of compressor fluid performance and system control near the critical point, but also the supporting technology issues of bearings, sealing technologies, and rotor windage losses which are also essential to achieving efficiency and cost objectives. These tests are providing the first measurements and information on these key supercritical CO 2 power conversion systems questions. Important data for all these issues has been obtained. This report presents the major results of the testing by showing and comparing the measured compressor performance map with the predicted performance. The compression loop uses a ∼50 kWe motor driven compressor to spin a 37 mm OD compressor at design speeds up to 75,000 rpm with a pressure ratio of 1.8 and a flow rate of 3.53 kg/s for a compressor inlet condition of 305.3 K and 7690 kPa. The most recent configuration of this loop has added a small turbine and 260 kW of heater power is

  10. SCTF Core-I test results

    International Nuclear Information System (INIS)

    Adachi, Hiromichi; Sudo, Yukio; Iwamura, Takamichi; Osakabe, Masahiro; Ohnuki, Akira; Hirano, Kemmei

    1982-07-01

    The Slab Core Test Facility (SCTF) of Japan Atomic Energy Research Institute (JAERI) was constructed to investigate two-dimensional thermohydrodynamics in the core and the communication in fluid behavior between the core and the upper plenum during the last part of blowdown, refill and reflood phases of a posturated loss-of-coolant accident (LOCA) of a pressurized water reactor (PWR). In the present report, effects of system pressure on reflooding phenomena shall be discussed based on the data of Tests S1-SH2, S1-01 and S1-02 which are the parameteris tests for system pressure effects belonging to the SCTF Core-I forced flooding test series. Major items discussed in this report are (1) hydrodynamic behavior in the system, (2) core thermal behavior, (3) core heat transfer and (4) two-dimensional hydrodynamic behavior in the pressure vessel including the core. (author)

  11. Reliability Estimation Based Upon Test Plan Results

    National Research Council Canada - National Science Library

    Read, Robert

    1997-01-01

    The report contains a brief summary of aspects of the Maximus reliability point and interval estimation technique as it has been applied to the reliability of a device whose surveillance tests contain...

  12. Test OPTRAN 1-1 results

    International Nuclear Information System (INIS)

    Martinson, Z.R.

    1982-01-01

    The objective of the OPT 1-1 Test Series was to evaluate the extent of damage and the threshold for failure during simulated BWR anticipated transients. Four power transient tests with progressively higher power levels were performed with preirradiated fuel rods at power ramp rates as high as 550 kW/m per second. Six separately shrouded fuel rods fabricated by the General Electric Co., and preirradiated in the Monticello BWR to burnups of about 5000 to 23,000 MWd/t were tested, four at a time. Four of the fuel rods were of typical GE 8 x 8 design, except for fuel length (0.75 m). Two of the rods included design modifications to improve their PCI-resistant characteristics. A lengthy fuel conditioning preceded the transient testing of the fuel rods

  13. Visual perception skills testing: preliminary results

    CSIR Research Space (South Africa)

    Smith, Andrew C

    2009-02-01

    Full Text Available Good visual perception skills are important in the effective manipulation of Tangible User Interfaces. This paper reports on the application of a test set researchers have developed specifically to quantify the visual perception skills of children...

  14. Overview of the PBF test results

    International Nuclear Information System (INIS)

    Zeile, H.J.

    1980-01-01

    The Thermal Fuels Behavior Program (TFBP) of EG and G Idaho conducts fuel behavior research in the Power Burst Facility (PBF) at INEL and at the Halden Reactor in Norway. The fuels behavior research in the PBF is directed toward providing a detailed understanding of the response of light water reactor (LWR) nuclear fuel assemblies to off-normal and hypothesized accident conditions. Single fuel rods and clusters of highly instrumented fuel rods are installed within a central test space of the PBF core for testing. The core can be operated in various modes to provide test conditions typical of accidents and off-normal conditions that may be experienced in a pressurized water reactor or a boiling water reactor

  15. Tests results of skutterudite based thermoelectric unicouples

    International Nuclear Information System (INIS)

    Saber, Hamed H.; El-Genk, Mohamed S.; Caillat, Thierry

    2007-01-01

    Tests were performed of skutterudite based unicouples with (MAY-04) and without (MAR-03) metallic coating on the legs near the hot junction to quantify the effect on reducing performance degradation with operation time. The p-legs in the unicouples were made of CeFe 3.5 Co 0.5 Sb 12 and the n-legs of CoSb 3 . The MAY-04 test was performed in vacuum (∼9 x 10 -7 torr) for ∼2000 h at hot and cold junction temperatures of 892.1 ± 11.9 K and 316.1 ± 5.5 K, respectively, while the MAR-03 test was performed in argon cover gas (0.051-0.068 MPa) at 972.61 ± 10.0 K and 301.1 ± 5.1 K, respectively. The argon cover gas decreased antimony loss from the legs in the MAR-03 test, but marked degradation in performance occurred over time. Conversely, the metallic coating in the MAY-04 test was very effective in reducing performance degradation of the unicouple. Because the cross sectional areas of the legs in MAY-04 were larger than those in MAR-03, the measured electrical power of the former is much higher than that of the latter, but the Beginning of Test (BOT) open circuit voltages, V oc (204.2 mV) for both unicouples were almost the same. The peak electrical power of the MAY-04 unicouple decreased 12.35% from 1.62W e at BOT to 1.42W e after ∼2000 h of testing, while that of the MAR-03 unicouple decreased 25.37% from 0.67 to 0.5W e after 261 h of testing at the above temperatures. The estimated peak efficiency of the MAY-04 unicouple, shortly after BOT (10.65%), was only ∼0.37% points lower than the theoretical value, calculated assuming zero side heat losses and zero contact resistance per leg

  16. Conventional fuel tank blunt impact tests : test and analysis results

    Science.gov (United States)

    2014-04-02

    The Federal Railroad Administrations Office of Research : and Development is conducting research into fuel tank : crashworthiness. A series of impact tests are planned to : measure fuel tank deformation under two types of dynamic : loading conditi...

  17. HERBE- Analysis of test operation results

    International Nuclear Information System (INIS)

    Pesic, M. et.al.

    1991-01-01

    This document is part of the safety analyses performed for the RB reactor operation with the coupled fast-thermal system HERBE and is part of the final safety report together with the 'Report on test operation of HERBE for the period Dec. 15 1989 - May 15 1990. This report covers the following main topics: determination of reactivity variations dependent on the variations moderator critical level; determination of reactivity for the flooded neutron converter; and the accident analysis of neutron converter flooding

  18. Results of Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Dieter R

    2003-06-13

    The beam experiments of Final Focus Test Beam (FFTB) started in September 1993 at SLAC, and have produced a 1.7 {micro}m x 75 nm spot of 46 GeV electron beam. A number of new techniques involving two nanometer spot-size monitors have been developed. Several beam diagnostic/tuning schemes are applied to achieve and maintain the small spot. This experiment opens the way toward the nanometer world for future linear colliders.

  19. Results of workplace drug testing in Norway

    Directory of Open Access Journals (Sweden)

    Hilde Marie Erøy Lund

    2011-12-01

    Full Text Available Workplace drug testing is less common in Norway than in many other countries. During the period from 2000-2006, 13469 urine or blood samples from employees in the offshore industry, shipping companies and aviation industry were submitted to the Norwegian Institute of Public Health for drug testing. The samples were analysed for benzodiazepines, illicit drugs, muscle relaxants with sedating properties, opioids and z-hypnotics. In total, 2.9% of the samples were positive for one or more substances. During the study period the prevalence decreased for morphine (from 1.9% to 1.1% and increased for amphetamine (from 0.04% to 0.6%, clonazepam (from 0% to 0.1%, methamphetamine (from 0.04% to 0.6%, nitrazepam (from 0% to 0.4% and oxazepam (from 0.5% to 1.3% (p<0.05. There was no significant change in prevalence for the other substances included in the analytical programme. Illicit drugs were significantly associated with lower age (OR: 0.93, p<0.05. This study found low prevalence of drugs among employees in companies with workplace drug testing programmes in Norway.

  20. The effect of HCV serological status on Doxorubicin based ...

    African Journals Online (AJOL)

    Karim Yousri Welaya

    2014-09-10

    Sep 10, 2014 ... Pretreatment evaluation included serological testing for HCV. FAC Adjuvant ... National Cancer Institute; IRB, Institutional Research Board; LVEF, ..... Mild Skin changes, including skin discoloration and nail changes, not ...

  1. AMORE Mo-99 Spike Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Youker, Amanda J. [Argonne National Lab. (ANL), Argonne, IL (United States); Krebs, John F. [Argonne National Lab. (ANL), Argonne, IL (United States); Quigley, Kevin J. [Argonne National Lab. (ANL), Argonne, IL (United States); Byrnes, James P. [Argonne National Lab. (ANL), Argonne, IL (United States); Rotsch, David A [Argonne National Lab. (ANL), Argonne, IL (United States); Brossard, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Wesolowski, Kenneth [Argonne National Lab. (ANL), Argonne, IL (United States); Alford, Kurt [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-09-27

    With funding from the National Nuclear Security Administrations Material Management and Minimization Office, Argonne National Laboratory (Argonne) is providing technical assistance to help accelerate the U.S. production of Mo-99 using a non-highly enriched uranium (non-HEU) source. A potential Mo-99 production pathway is by accelerator-initiated fissioning in a subcritical uranyl sulfate solution containing low enriched uranium (LEU). As part of the Argonne development effort, we are undertaking the AMORE (Argonne Molybdenum Research Experiment) project, which is essentially a pilot facility for all phases of Mo-99 production, recovery, and purification. Production of Mo-99 and other fission products in the subcritical target solution is initiated by putting an electron beam on a depleted uranium (DU) target; the fast neutrons produced in the DU target are thermalized and lead to fissioning of U-235. At the end of irradiation, Mo is recovered from the target solution and separated from uranium and most of the fission products by using a titania column. The Mo is stripped from the column with an alkaline solution. After acidification of the Mo product solution from the recovery column, the Mo is concentrated (and further purified) in a second titania column. The strip solution from the concentration column is then purified with the LEU Modified Cintichem process. A full description of the process can be found elsewhere [1–3]. The initial commissioning steps for the AMORE project include performing a Mo-99 spike test with pH 1 sulfuric acid in the target vessel without a beam on the target to demonstrate the initial Mo separation-and-recovery process, followed by the concentration column process. All glovebox operations were tested with cold solutions prior to performing the Mo-99 spike tests. Two Mo-99 spike tests with pH 1 sulfuric acid have been performed to date. Figure 1 shows the flow diagram for the remotely operated Mo-recovery system for the AMORE project

  2. SURVEY RESULTS AND TESTING OF RAILWAY BRIDGES

    Directory of Open Access Journals (Sweden)

    I. H. Haniiev

    2010-03-01

    Full Text Available The article is devoted to the survey and testing of railway bridges by the State Joint-Stock Railway Company «Uzbekiston Temir Yollari» («Uzbekistan Railways». It is stated that in the existing rules on determination of the capacity of bridges the recommendations on taking into account the cumulative deflection to the moment of technical diagnostics of spans on the bridge capacity are absent. The author states on the need to develop a method for determining the wear of spans on restriction of the residual deflection in the bridge floor slabs.

  3. Fort St. Vrain hot functional test results

    International Nuclear Information System (INIS)

    Phelps, R.D.

    1974-01-01

    A description is given of Fort St. Vrain hot functional tests performed to evaluate the initial nonnuclear performance of the primary coolant system and the associated effects on the various internal components of the reactor vessel and primary coolant system. The components included the twelve steam generator modules, the four helium circulators, the PCRV thermal barrier and liner coolant system, the helium purification system, and the primary and secondary closures at each of the PCRV penetrations. Additional objectives included analysis of the parallel operation of the four helium circulators and the performance of several circulator start/stop transients under various conditions of primary coolant temperature and pressure. Vibration and acoustical phenomena within the vessel were measured, recorded, and compared to theoretical analyses; a verification of reverse flow in the shutdown loop steam generator during one loop operation was performed; the PCRV was again observed for its structural response to internal pressure; and comparisons were made relative to data recorded during the initial pressure test completed in July 1971. (U.S.)

  4. Tests of a photovoltaic pump: first results

    International Nuclear Information System (INIS)

    Petroselli, A.; Pica, M.; Biondi, P.

    2005-01-01

    The paper deals with a first series of tests conducted in Viterbo (42 deg 25 min North, 12 deg 06 min East) on a PV-DC pump. This series lasted eight months - from the first days of January to the end of August 2003 - and involved measurements of: air and PV-module temperatures; solar radiations, both on horizontal surface and tilted module surface; voltage and intensity of the DC currents from the panel; pump pressures and flow rates. In total, as much as 3,150 data were collected every day. The analysis of the data allowed to obtain some simple empirical relations expressing daily pumped water volumes, instantaneous flow rates and system efficiencies as a function of both radiations and total dynamic heads [it

  5. RESULTS OF INITIAL AMMONIA OXIDATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fowley, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-30

    This memo presents an experimental survey of aqueous phase chemical processes to remove aqueous ammonia from waste process streams. Ammonia is generated in both the current Hanford waste flowsheet and in future waste processing. Much ammonia will be generated in the Low Activity Waste (LAW) melters.i Testing with simulants in glass melters at Catholic University has demonstrated the significant ammonia production.ii The primary reaction there is the reducing action of sugar on nitrate in the melter cold cap. Ammonia has been found to be a problem in secondary waste stabilization. Ammonia vapors are noxious and destruction of ammonia could reduce hazards to waste treatment process personnel. It is easily evolved especially when ammonia-bearing solutions are adjusted to high pH.

  6. Middleware for big data processing: test results

    Science.gov (United States)

    Gankevich, I.; Gaiduchok, V.; Korkhov, V.; Degtyarev, A.; Bogdanov, A.

    2017-12-01

    Dealing with large volumes of data is resource-consuming work which is more and more often delegated not only to a single computer but also to a whole distributed computing system at once. As the number of computers in a distributed system increases, the amount of effort put into effective management of the system grows. When the system reaches some critical size, much effort should be put into improving its fault tolerance. It is difficult to estimate when some particular distributed system needs such facilities for a given workload, so instead they should be implemented in a middleware which works efficiently with a distributed system of any size. It is also difficult to estimate whether a volume of data is large or not, so the middleware should also work with data of any volume. In other words, the purpose of the middleware is to provide facilities that adapt distributed computing system for a given workload. In this paper we introduce such middleware appliance. Tests show that this middleware is well-suited for typical HPC and big data workloads and its performance is comparable with well-known alternatives.

  7. INTRAVAL test case 1b - modelling results

    International Nuclear Information System (INIS)

    Jakob, A.; Hadermann, J.

    1991-07-01

    This report presents results obtained within Phase I of the INTRAVAL study. Six different models are fitted to the results of four infiltration experiments with 233 U tracer on small samples of crystalline bore cores originating from deep drillings in Northern Switzerland. Four of these are dual porosity media models taking into account advection and dispersion in water conducting zones (either tubelike veins or planar fractures), matrix diffusion out of these into pores of the solid phase, and either non-linear or linear sorption of the tracer onto inner surfaces. The remaining two are equivalent porous media models (excluding matrix diffusion) including either non-linear sorption onto surfaces of a single fissure family or linear sorption onto surfaces of several different fissure families. The fits to the experimental data have been carried out by Marquardt-Levenberg procedure yielding error estimates of the parameters, correlation coefficients and also, as a measure for the goodness of the fits, the minimum values of the χ 2 merit function. The effects of different upstream boundary conditions are demonstrated and the penetration depth for matrix diffusion is discussed briefly for both alternative flow path scenarios. The calculations show that the dual porosity media models are significantly more appropriate to the experimental data than the single porosity media concepts. Moreover, it is matrix diffusion rather than the non-linearity of the sorption isotherm which is responsible for the tailing part of the break-through curves. The extracted parameter values for some models for both the linear and non-linear (Freundlich) sorption isotherms are consistent with the results of independent static batch sorption experiments. From the fits, it is generally not possible to discriminate between the two alternative flow path geometries. On the basis of the modelling results, some proposals for further experiments are presented. (author) 15 refs., 23 figs., 7 tabs

  8. Serological diagnosis of Taenia solium in pigs: No measurable circulating antigens and antibody response following exposure to Taenia saginata oncospheres.

    Science.gov (United States)

    Dorny, P; Dermauw, V; Van Hul, A; Trevisan, C; Gabriël, S

    2017-10-15

    Taenia solium taeniasis/cysticercosis is a zoonosis included in the WHO's list of neglected tropical diseases. Accurate diagnostic tools for humans and pigs are needed to monitor intervention outcomes. Currently used diagnostic tools for porcine cysticercosis all have drawbacks. Serological tests are mainly confronted with problems of specificity. More specifically, circulating antigen detecting tests cross-react with Taenia hydatigena and the possibility of transient antigens as a result of aborted infections is suspected. Furthermore, the hypothesis has been raised that hatched ingested eggs of other Taenia species may lead to a transient antibody response or to the presence of circulating antigen detectable by serological tests used for porcine cysticercosis. Here we describe the results of a study that consisted of oral administration of Taenia saginata eggs to five piglets followed by serological testing during five weeks and necropsy aiming at studying possible cross reactions in serological tests used for porcine cysticercosis. The infectivity of the eggs was verified by in vitro hatching and by experimental infection of a calf. One piglet developed acute respiratory disease and died on day 6 post infection. The remaining four piglets did not show any clinical signs until euthanasia. None of the serum samples from four piglets collected between days 0 and 35 post infection gave a positive reaction in the B158/B60 Ag-ELISA and in a commercial Western blot for antibody detection. In conclusion, this study showed that experimental exposure of four pigs to T. saginata eggs did not result in positive serologies for T. solium. These results may help interpreting serological results in monitoring of T. solium control programmes. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Serologic survey for brucellosis in feral swine, wild ruminants, and black bear of California, 1977 to 1989.

    Science.gov (United States)

    Drew, M L; Jessup, D A; Burr, A A; Franti, C E

    1992-07-01

    A retrospective analysis of brucellosis serologic testing results in eight wildlife species in California from 1977 to 1989 was done. Samples were collected from 5,398 live-captured or hunter-killed animals and tested by combinations of up to six serologic tests for antibodies to Brucella spp. Twenty-three of 611 (3.8%) feral swine (Sus scrofa), one of 180 (0.6%) black bear (Ursus americanus), one of 355 (0.3%) California mule deer (Odocoileus hemionus californicus), and one of 1,613 (0.06%) blacktail deer (Odocoileus hemionus columbianus) samples were considered reactors. Suspect serologic reactions occurred in three of 619 (0.5%) desert bighorn sheep (Ovis canadensis nelsoni) and one of 355 (0.3%) California mule deer samples. Brucellosis is not considered an important wildlife health problem in California except in feral swine.

  10. Large bundle BWR test CORA-18: Test results

    International Nuclear Information System (INIS)

    Hagen, S.; Hofmann, P.; Noack, V.; Sepold, L.; Schanz, G.; Schumacher, G.

    1998-04-01

    The CORA out-of-pile experiments are part of the international Severe Fuel Damage (SFD) Program. They were performed to provide information on the damage progression of Light Water Reactor (LWR) fuel elements in Loss-of-coolant Accidents in the temperature range 1200 C to 2400 C. CORA-18 was the large BWR bundle test corresponding to the PWR test CORA-7. It should investigate if there exists an influence of the BWR bundle size on the fuel damage behaviour. Therefore, the standard-type BWR CORA bundle with 18 fuel rod simulators was replaced by a large bundle with two additional surrounding rows of 30 rods (48 rods total). Power input and steam flow were increased proportionally to the number of fuel rod simulators to give the same initial heat-up rate of about 1 K/s as in the smaller bundles. Emphasis was put on the initial phase of the damage progression. More information on the chemical composition of initial and intermediate interaction products and their relocation behaviour should be obtained. Therefore, power and steam input were terminated after the onset of the temperature escalation. (orig.) [de

  11. Stirling convertor performance mapping test results

    Science.gov (United States)

    Qiu, Songgang; Peterson, Allen A.; White, Maurice A.; Faultersack, Franklyn; Redinger, Darin L.; Petersen, Stephen L.

    2002-01-01

    The Department of Energy (DOE) has selected Free-Piston Stirling Convertors as a technology for future advanced radioisotope space power systems. In August 2000, DOE awarded competitive Phase I, Stirling Radioisotope Generator (SRG) power system integration contracts to three major aerospace contractors, resulting in SRG conceptual designs in February 2001. All three contractors based their designs on the Technology Demonstration Convertor (TDC) developed by Stirling Technology Company (STC) for DOE. The contract award to a single system integration contractor for Phases II and III of the SRG program is anticipated in late 2001. The first potential SRG mission is targeted for a Mars rover. Recent TDC performance data are provided in this paper, together with predictions from Stirling simulation models. .

  12. Effect of 25-Hydroxyvitamin D Status on Serological Response to Influenza Vaccine in Prostate Cancer Patients

    Science.gov (United States)

    Chadha, Manpreet K.; Fakih, Marwan; Muindi, Josephia; Tian, Lili; Mashtare, Terry; Johnson, Candace S.; Trump, Donald

    2015-01-01

    BACKGROUND Epidemiologic data suggest that there is an association between vitamin D deficiency and influenza infection. We conducted a prospective influenza vaccination study to determine the influence of vitamin D status on serological response to influenza vaccine in prostate cancer (CaP) patients. METHODS During the 2006–2007 influenza season, CaP patients treated at Roswell Park Cancer Institute were offered vaccination with the trivalent influenza vaccine (Fluzone®, 2006–2007) and sera collected for hemagglutination inhibition (HI) assay titers before and 3 months after vaccination. Response to vaccination was defined as ≥1:40 titer ratio or a fourfold increase in titer at 3 months, against any of the three strains. Serum 25-hydroxyvitamin D (25-D3) levels were measured using DiaSorin 125I radioimmunoassay kits. RESULTS Thirty-five patients with CaP participated in the study. Median baseline 25-D3 level was 44.88 ng/ml (range: 9.16–71.98 ng/ml) Serological response against any of the three strains was noted in 80%. There was a significant effect of baseline 25-D3 level when tested as a continuous variable in relation to serological response (P = 0.0446). All patients in the upper quartile of 25-D3 level responded by mounting a serological response (P = 0.0344). None of the other baseline variables (age, race, chemotherapy status, or white cell count) had an effect on serological response. CONCLUSIONS In this study in CaP patients, a replete vitamin D status was associated with more frequent serological response to influenza vaccine. PMID:20812224

  13. Health screening of migrant workers- serological investigations

    International Nuclear Information System (INIS)

    Mustafa, M.

    2009-01-01

    The paper review the serological investigations for parasitic infection among migrant workers. The tests were performed on serum samples for parasitic infection. The serum samples were found to be positive for antibody for Ameobiasis [28%], Malaria [27 percentage], Echonococcus [18 percentage] and Schistosomiasis [12 percentage]. Female samples were positive for Ameobiasis [39 percentage], and Filariasis [W.b] 33.3 percentage. Foreign workers from Bangladesh showed the highest percentage on seropositive for most parasitic diseases. (author)

  14. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  15. Aspectos da padronização de testes sorológicos para a doença de Chagas: um teste imunoenzimático para a triagem de doadores de sangue Standardization of serological tests in Chagas' disease: immunoenzimatic test for screening of blood bank donnors

    Directory of Open Access Journals (Sweden)

    A. Walter Ferreira

    1991-04-01

    Full Text Available No diagnóstico sorológico da doença de Chagas podem ser encontradas acentuadas divergências mesmo entre laboratórios de grande experiência. Para a padronização de um teste imunoenzimático destinado primariamente à seleção de doadores de sangue foram cuidadosamente escolhidos painéis de soros que se buscaram como representativos das populações de chagásicos e de não chagásicos. Produzido para máxima sensibilidade e estabilidade, o novo reagente (bioELISA - cruzi* foi testado em 1648 soros, com diagnóstico clínico de doença de Chagas em 219 e de outras afecções em 104. O teste foi comparado com testes já bem padronizados, de imunofluorescência (IF e de hemaglutinação (HA, em 1325 soros. O limiar de reatividade (cut off, estabelecido como ideal, foi indicado nos testes pela absorbância de um soro de reatividade mínima. A sensibilidade do teste imunoenzimático foi de 0,9954 e a especificidade, como conegatividade, de 0,9969. Não foram vistos resultados falso-positivos em casos de sífilis, toxoplasmose, mononucleose e de soros com altos títulos de anti-estreptolisina 0, mas foram encontrados em 5 de 15 casos de leishmaniose tegumentar, 10 de 24 casos de calazar, 1 de 15 casos de artrite reumatóide e 1 de 12 casos de lupus eritematoso sistêmico. Os altos índices de sensibilidade em chagásicos e de especificidade na população geral, traduzem a elevada confiabilidade do teste para triagem de doadores de sangue e para a confirmação de suspeita clínica de doença de Chagas.In the serological diagnosis of Chagas disease large divergences may be found even between laboratories with experience, as a consequence of different criteria for the standardization of the tests. To standardize a immunoenzimatic test developed primarily for screening blood donors, serum panels were carefully chosen so as to best represent chagasic and non-chagasic populations. Produced for the highest sensibility and stability, the new

  16. Chagas cardiomyopathy and serologic testing in a small rural hospital in Chiapas, Mexico Miocardiopatía chagásica y pruebas serológicas de enfermedad de Chagas en un hospital rural pequeño de Chiapas, México

    Directory of Open Access Journals (Sweden)

    Linnea Capps

    2004-05-01

    Full Text Available OBJECTIVES: To conduct a study in a small rural hospital located in the state of Chiapas, Mexico, to: (1 examine the prevalence of chagasic cardiomyopathy among patients with the diagnosis of congestive heart failure and (2 assess the prevalence of positive serologic results in blood donors in the hospital, in an attempt to ascertain whether Chagas' disease remains an important cause of heart failure at least in some areas of Mexico. METHODS: The study of patients with cardiomyopathy was conducted by retrospective chart review of patients with the diagnosis of congestive heart failure treated at the hospital during the years 2000­2002. With the blood donors, the results of their serologic screening were reviewed for a six-month period beginning in April 2002. Serologic testing was done in both groups with either indirect hemagglutination (IHA or enzyme-linked immunosorbent assay (ELISA, or with both. RESULTS: Of 67 patients with heart failure and no risk factors for other causes of heart failure, 40 of them had serologic tests performed. Thirty-three of these 40 (82.5% were positive by ELISA, IHA, or both. With 97 blood donors, one or both serologic tests were positive in 17 of them (17.5%. CONCLUSIONS: This research adds to the evidence that Chagas' disease continues to be a major cause of heart failure in some areas of Mexico and that there continues to be a risk of transmission by blood transfusion if donated blood is not consistently screened.OBJETIVO: Llevar a cabo un estudio en un hospital rural pequeño del Estado de Chiapas, México, con el fin de: 1 examinar la prevalencia de miocardiopatía chagásica en pacientes con un diagnóstico de insuficiencia cardíaca congestiva y 2 estimar la prevalencia de positividad serológica en donantes de sangre del hospital, con objeto de determinar si la enfermedad de Chagas sigue siendo una causa importante de insuficiencia cardíaca en algunas partes de México. MÉTODOS: El estudio de los

  17. Evolution of hepatitis B serological markers in HIV coinfected patients: a case study

    Directory of Open Access Journals (Sweden)

    Ana Luiza de Castro Conde Toscano

    Full Text Available ABSTRACT OBJECTIVE To describe the evolution of serological markers among HIV and hepatitis B coinfected patients, with emphasis on evaluating the reactivation or seroreversion of these markers. METHODS The study population consisted of patients met in an AIDS Outpatient Clinic in São Paulo State, Brazil. We included in the analysis all HIV-infected and who underwent at least two positive hepatitis B surface antigen serological testing during clinical follow up, with tests taken six months apart. Patients were tested with commercial kits available for hepatitis B serological markers by microparticle enzyme immunoassay. Clinical variables were collected: age, sex, CD4+ T-cell count, HIV viral load, alanine aminotransferase level, exposure to antiretroviral drugs including lamivudine and/or tenofovir. RESULTS Among 2,242 HIV positive patients, we identified 105 (4.7% patients with chronic hepatitis B. Follow up time for these patients varied from six months to 20.5 years. All patients underwent antiretroviral therapy during follow-up. Among patients with chronic hepatitis B, 58% were hepatitis B “e” antigen positive at the first assessment. Clearance of hepatitis B surface antigen occurred in 15% (16/105 of patients with chronic hepatitis B, and 50% (8/16 of these patients presented subsequent reactivation or seroreversion of hepatitis B surface antigen. Among hepatitis B “e” antigen positive patients, 57% (35/61 presented clearance of this serologic marker. During clinical follow up, 28.5% (10/35 of those who initially cleared hepatitis B “e” antigen presented seroreversion or reactivation of this marker. CONCLUSIONS Among HIV coinfected patients under antiretroviral therapy, changes of HBV serological markers were frequently observed. These results suggest that frequent monitoring of these serum markers should be recommended.

  18. Improved reliability of serological tools for the diagnosis of West Nile fever in horses within Europe.

    Directory of Open Access Journals (Sweden)

    Cécile Beck

    2017-09-01

    Full Text Available West Nile Fever is a zoonotic disease caused by a mosquito-borne flavivirus, WNV. By its clinical sensitivity to the disease, the horse is a useful sentinel of infection. Because of the virus' low-level, short-term viraemia in horses, the primary tools used to diagnose WNV are serological tests. Inter-laboratory proficiency tests (ILPTs were held in 2010 and 2013 to evaluate WNV serological diagnostic tools suited for the European network of National Reference Laboratories (NRLs for equine diseases. These ILPTs were designed to evaluate the laboratories' and methods' performances in detecting WNV infection in horses through serology. The detection of WNV immunoglobulin G (IgG antibodies by ELISA is widely used in Europe, with 17 NRLs in 2010 and 20 NRLs in 2013 using IgG WNV assays. Thanks to the development of new commercial IgM capture kits, WNV IgM capture ELISAs were rapidly implemented in NRLs between 2010 (4 NRLs and 2013 (13 NRLs. The use of kits allowed the quick standardisation of WNV IgG and IgM detection assays in NRLs with more than 95% (20/21 and 100% (13/13 of satisfactory results respectively in 2013. Conversely, virus neutralisation tests (VNTs were implemented in 33% (7/21 of NRLs in 2013 and their low sensitivity was evidenced in 29% (2/7 of NRLs during this ILPT. A comparison of serological diagnostic methods highlighted the higher sensitivity of IgG ELISAs compared to WNV VNTs. They also revealed that the low specificity of IgG ELISA kits meant that it could detect animals infected with other flaviviruses. In contrast VNT and IgM ELISA assays were highly specific and did not detect antibodies against related flaviviruses. These results argue in favour of the need for and development of new, specific serological diagnostic assays that could be easily transferred to partner laboratories.

  19. Serological survey of Leishmania infection in dogs from the municipality of Peso da Régua (Alto Douro, Portugal) using the direct agglutination test (DAT) and fast agglutination screening test (FAST)

    NARCIS (Netherlands)

    Cardoso, Luís; Schallig, Henk D. F. H.; Neto, Francisco; Kroon, Nel; Rodrigues, Manuela

    2004-01-01

    Leishmaniasis caused by Leishmania infantum is a prevalent disease in dogs and humans. A serological survey of Leishmania infection in dogs was carried out in the endemic region of Alto Douro (north Portugal). Two hundred and ninety-four dogs from the municipality of Peso da Régua were examined for

  20. Detection of Brucella sp. infection through serological, microbiological, and molecular methods applied to buffaloes in Maranhão State, Brazil.

    Science.gov (United States)

    Dos Santos, Larissa Sarmento; Sá, Joicy Cortez; Dos Santos Ribeiro, Diego Luiz; Chaves, Nancyleni Pinto; da Silva Mol, Juliana Pinto; Santos, Renato Lima; da Paixão, Tatiane Alves; de Carvalho Neta, Alcina Vieira

    2017-04-01

    The aim of the current study is to diagnose Brucella spp. infection using methods such as serology, bacterial isolation, and molecular analysis in buffaloes bred in Maranhão State. In order to do so, 390 samples of buffalo serum were subjected to serological tests, to Rose Bengal Plate Test (RBPT) and to 2-mercaptoethanol (2-ME) combined with slow agglutination test (SAT). Vaginal swabs were collected from seropositive animals and subjected to bacterial isolation and to generic PCR. According to the serological test, 16 animals had a positive reaction to the confirmatory test (2-ME/SAT). As for bacterial isolation, three samples resulted in the isolation of Brucella spp.-characteristic colonies, which were confirmed through PCR. These results confirmed Brucella spp. infection in the buffalo herd from Maranhão State.

  1. Comparative evaluation of positive tests to Mycobacterium avium subsp. paratuberculosis in clinically healthy sheep and goats in south-west Greece using molecular techniques, serology, and culture.

    Science.gov (United States)

    Ikonomopoulos, John; Balaskas, Christos; Kantzoura, Bagia; Fragiadaki, Eirini; Pavlik, Ivo; Bartos, Milan; Lukas, John C; Gazouli, Maria

    2007-09-01

    Mycobacterium avium subsp. paratuberculosis (MAP) is the cause of paratuberculosis, which affects mainly ruminants although there is a growing concern about its possible implication in Crohn's disease in humans especially in connection with environmental spread and risks to the food chain. Retail cheese may represent a significant source of human exposure to MAP and the aim of this study was to assess MAP status in clinically healthy sheep and goats in Greece, comparing techniques routinely used in the positive diagnosis of the disease. From a total of 30 flocks, 632 sheep and goats had faecal, serum, and whole-blood samples examined by culture, complement fixation test (CFT), and polymerase chain reaction (PCR) targeted at IS900, IS1245, and IS6110. PCR produced positive results in 21% of the animals tested, with 5.6%, 3.9%, and 11.5% being identified as MAP, Mycobacterium avium subsp. avium, and Mycobacterium tuberculosis complex, respectively. CFT produced positive and suspicious results in 4.4% and 14.4% of the cases. Faecal cultures were negative in all but a single case that was identified as restriction fragment length polymorphism (RFLP)-type BC1. Agreement between results obtained by PCR and CFT was poor with isolated cases although an assessment of the MAP positive tests produced similar results for both methods. The findings indicate the need for additional measures of control, although the costs may be substantial if public health protection justifies elimination of MAP from livestock.

  2. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  3. Mycological and serological study of pulmonary aspergillosis in central India

    Directory of Open Access Journals (Sweden)

    Kurhade A

    2002-01-01

    Full Text Available PURPOSE: To study the prevalence and predisposing factors of Aspergillus infection and correlate microscopic, culture and serological findings along with drug sensitivity. METHODS: Sputum samples from 123 patients of pulmonary disease with clinical suspicion of having fungal, especially Aspergillus infections, were examined microscopically and for culture. Minimum inhibitory concentration (MIC of itraconazole was tested against the isolates. Serum samples from these patients were tested for precipitin against Aspergillus antigen using immunodiffusion (ID technique. RESULTS: Aspergillus species were isolated in 20 (16.26% cases and Aspergillus fumigatus was the predominant species isolated in 16 (80% cases. Precipitins were detected in 29 (23.58% cases. Serum samples collected from 50 healthy individuals to serve as controls showed no precipitin against Aspergillus antigen galactomannan. This fungus was found to be sensitive to itraconazole with MIC range 0.125-1µg/mL. CONCLUSIONS: Serological tests have an edge over routine smear and culture methods for the diagnosis of pulmonary aspergillosis. Itraconazole is more effective than amphotericin B and fluconazole in the treatment of aspergillosis.

  4. Old and new diagnostic approaches for Q fever diagnosis: correlation among serological (CFT, ELISA) and molecular analyses.

    Science.gov (United States)

    Natale, A; Bucci, G; Capello, K; Barberio, A; Tavella, A; Nardelli, S; Marangon, S; Ceglie, L

    2012-07-01

    The objective of this study was to evaluate the performance of the complement fixation test (CFT) with respect to ELISA for the serological diagnosis of Q fever and to assess the role of serology as a tool for the identification of the shedder status. During 2009-2010, sera from 9635 bovines and 3872 small ruminants (3057 goats and 815 sheep) were collected and analyzed with CFT and ELISA. In addition, 2256 bovine, 139 caprine and 72 ovine samples (individual and bulk tank milk samples, fetuses, vaginal swabs and placentae) were analyzed with a real-time PCR kit. The relative sensitivity (Se) and specificity (Sp) of CFT with respect to ELISA were Se 26.56% and Sp 99.71% for cattle and Se 9.96% and Sp 99.94% for small ruminants. To evaluate the correlation between serum-positive status and shedder status, the ELISA, CFT and real-time PCR results were compared. Due to the sampling method and the data storage system, the analysis of individual associations between the serological and molecular tests was possible only for some of the bovine samples. From a statistical point of view, no agreement was observed between the serological and molecular results obtained for fetus and vaginal swab samples. Slightly better agreement was observed between the serological and molecular results obtained for the individual milk samples and between the serological (at least one positive in the examined group) and molecular results for the bulk tank milk (BTM) samples. The CFT results exhibited a better correlation with the shedder status than did the ELISA results. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Elaboration and quality control of the inoculum of the experimental vaccine Brucella S19-tn7-GFP for use in white animals and associated serological test for the detection of anti-GFP antibodies

    International Nuclear Information System (INIS)

    Salas Alfaro, Dariana

    2014-01-01

    The preparation of the inoculum of the experimental vaccine Brucella S19-Tn7-GFP is optimized for application in white animals. An associated serological test has allowed differentiating infected animals from those vaccinated with the experimental strain. The same bacteriological and biological properties of the B. abortus S19-Tn7-GFP strain have maintained in the parental vaccine strain S19 and is stable over time. A protocol for the inoculums of strain S19-Tn7-GFP is established for its preparation and use in white animals and quality control. The inoculum stability is evaluated through the simulation of conditions that can be presented in the transportation and application process in the field. An enzyme immunoassay ELISA is optimized for the detection of anti-GFP antibodies in cattle [es

  6. Serological diagnosis of bovine brucellosis using B. melitensis strain B115.

    Science.gov (United States)

    Corrente, Marialaura; Desario, Costantina; Parisi, Antonio; Grandolfo, Erika; Scaltrito, Domenico; Vesco, Gesualdo; Colao, Valeriana; Buonavoglia, Domenico

    2015-12-01

    Bovine brucellosis is diagnosed by official tests, such as Rose Bengal plate test (RBPT) and Complement Fixation test (CFT). Both tests detect antibodies directed against the lipolysaccharide (LPS) of Brucella cell wall. Despite their good sensitivity, those tests do not discriminate between true positive and false positive serological reactions (FPSR), the latter being generated by animals infected with other Gram negative microorganisms that share components of Brucella LPS. In this study, an antigenic extract from whole Brucella melitensis B115 strain was used to set up an ELISA assay for the serological diagnosis of bovine brucellosis. A total of 148 serum samples from five different groups of animals were tested: Group A: 28 samples from two calves experimentally infected with Yersinia enterocolitica O:9; Group B: 30 samples from bovines infected with Brucella abortus; Group C: 50 samples from brucellosis-free herds; Group D: 20 samples RBPT positive and CFT negative; Group E: 20 samples both RBPT and CFT positive. Group D and Group E serum samples were from brucellosis-free herds. Positive reactions were detected only by RBPT and CFT in calves immunized with Y. enterocolitica O:9. Sera from Group B animals tested positive also in the ELISA assay, whereas sera from the remaining groups were all negative. The results obtained encourage the use of the ELISA assay to implement the serological diagnosis of brucellosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Comparison between two commercially available serological tests and polymerase chain reaction in the diagnosis of Cryptosporidium in animals and diarrhoeic children.

    Science.gov (United States)

    Helmy, Yosra A; Krücken, Jürgen; Nöckler, Karsten; von Samson-Himmelstjerna, Georg; Zessin, Karl-H

    2014-01-01

    For the detection of Cryptosporidium species in 804 animals and 165 diarrhoeic children (tests, the RIDASCREEN® Cryptosporidium test [enzyme immunoassay (EIA)] and the RIDA®QUICK Cryptosporidium/Giardia Combi [immuno-chromatographic test (ICT)] as well as polymerase chain reaction (PCR) were used. Prevalence of Cryptosporidium was 15.0, 19.5 and 32.3% in animals and 2.4, 6.7 and 49.1% in children using EIA, ICT and PCR, respectively.Using PCR as reference method, animal samples sensitivity (Se) of the EIA was 46.5% when questionable samples were considered positive, whereas specificity (Sp) was 100%. Se of the ICT was 60.4% while Sp was 100%. Positive predictive values (PPVs) for both EIA and ICT test were 100%, and negative predictive values (NPVs) for EIA were 79.7 and 84.1% for ICT. For the children samples, the Se of EIA was 5%, Sp was 100%, PPV was 100% and NPV was 52.2%, while the Se of ICT was 13.6%, Sp was 100%, PPV was 100% and NPV was 54.6%.The Kappa score of agreement between PCR and ICT was 67.4%, 54.1% between PCR and EIA and 84.4% between ICT and EIA. Until the second serial dilution of the EIA and ICT test, 9 × 10(3) oocysts/μl of Cryptosporidia was detected, whereas in PCR, they were detected until the sixth serial dilution. Copro-antigen tests were easy to perform and less time-consuming but less sensitive compared to PCR. They obviously are best applicable for screening and epidemiological studies of large numbers of subjects, for batch specimen processing and in isolated or rural areas where reliable tests like PCR are unfeasible. When in children, a single stool sample is used for the diagnosis of clinical cases; better results can be obtained when non-standardized PCR due low specificity is coupled with copro-antigen tests.

  8. Barriers impeding serologic screening for celiac disease in clinically high-prevalence populations

    Science.gov (United States)

    2014-01-01

    Background Celiac disease is present in ~1% of the general population in the United States and Europe. Despite the availability of inexpensive serologic screening tests, ~85% of individuals with celiac disease remain undiagnosed and there is an average delay in diagnosis of symptomatic individuals with celiac disease that ranges from ~5.8-11 years. This delay is often attributed to the use of a case-based approach for detection rather than general population screening for celiac disease, and deficiencies at the level of health care professionals. This study aimed to assess if patient-centered barriers have a role in impeding serologic screening for celiac disease in individuals from populations that are clinically at an increased risk for celiac disease. Methods 119 adults meeting study inclusion criteria for being at a higher risk for celiac disease were recruited from the general population. Participants completed a survey/questionnaire at the William K. Warren Medical Research Center for Celiac Disease that addressed demographic information, celiac disease related symptoms (gastrointestinal and extraintestinal), family history, co-morbid diseases and conditions associated with celiac disease, and patient-centered barriers to screening for celiac disease. All participants underwent serologic screening for celiac disease using the IgA tissue transglutaminase antibody (IgA tTG) and, if positive, testing for IgA anti-endomysial antibody (IgA EMA) as a confirmatory test. Results Two barriers to serologic testing were significant across the participant pool. These were participants not knowing they were at risk for celiac disease before learning of the study, and participants not knowing where to get tested for celiac disease. Among participants with incomes less than $25,000/year and those less than the median age, not having a doctor to order the test was a significant barrier, and this strongly correlated with not having health insurance. Symptoms and co

  9. Isolation and serological identification of enteropathogenic Escherichia coli in pasteurized milk in Brazil

    Directory of Open Access Journals (Sweden)

    Zoraide N da Silva

    2001-08-01

    Full Text Available OBJECTIVE: To evaluate the microbiological quality of pasteurized milk commercialized in Rio de Janeiro, Brazil, and determine serologically enteropathogenic Escherichia coli (EPEC strains in E. coli isolates obtained from milk samples. METHODS: Ninety samples of pasteurized milk -- types B and C -- of three different commercial brands, purchased in supermarkets and bakeries in Rio de Janeiro, were examined. The amount of total and fecal coliform bacteria was estimated using the Most Probable Number technique. Mesophilic, psychrotrophic, and thermoduric microorganism counts were determined by the Standard Plate Count technique. Isolation and identification of E. coli were carried out using conventional physiological tests. Commercial antisera were used for serological characterization of EPEC. RESULTS: The three milk brands analyzed revealed bacterial counts above the regulated values of the Brazilian government. It was found that among 208 strains of E. coli isolated, 46 (22.1% were serologically classified as EPEC. The most common EPEC serogroup was O55 (15.2%. CONCLUSIONS: Though recent studies on virulence factors indicate that not all strains serologically classified as EPEC are able to attaching/effacing lesion, it is believed that the isolation of EPEC serogroups from pasteurized milk represent a potential risk for children, as well as an indicative of the presence of other enteropathogens.

  10. Serologic Screening for Genital Herpes Infection: US Preventive Services Task Force Recommendation Statement.

    Science.gov (United States)

    Bibbins-Domingo, Kirsten; Grossman, David C; Curry, Susan J; Davidson, Karina W; Epling, John W; García, Francisco A R; Kemper, Alex R; Krist, Alex H; Kurth, Ann E; Landefeld, C Seth; Mangione, Carol M; Phillips, William R; Phipps, Maureen G; Pignone, Michael P; Silverstein, Michael; Tseng, Chien-Wen

    2016-12-20

    Genital herpes is a prevalent sexually transmitted infection in the United States, occurring in almost 1 in 6 persons aged 14 to 49 years. Infection is caused by 2 subtypes of the herpes simplex virus (HSV), HSV-1 and HSV-2. Antiviral medications may provide symptomatic relief from outbreaks but do not cure HSV infection. Neonatal herpes infection, while uncommon, can result in substantial morbidity and mortality. To update the 2005 US Preventive Services Task Force (USPSTF) recommendation on screening for genital herpes. The USPSTF reviewed the evidence on the accuracy, benefits, and harms of serologic screening for HSV-2 infection in asymptomatic persons, including those who are pregnant, as well as the effectiveness and harms of preventive medications and behavioral counseling interventions to reduce future symptomatic episodes and transmission to others. Based on the natural history of HSV infection, its epidemiology, and the available evidence on the accuracy of serologic screening tests, the USPSTF concluded that the harms outweigh the benefits of serologic screening for genital HSV infection in asymptomatic adolescents and adults, including those who are pregnant. The USPSTF recommends against routine serologic screening for genital HSV infection in asymptomatic adolescents and adults, including those who are pregnant. (D recommendation).

  11. Validation of Geno-Sen's scrub typhus real time polymerase chain reaction kit by its comparison with a serological ELISA Test

    Directory of Open Access Journals (Sweden)

    Velmurugan Anitharaj

    2017-01-01

    Full Text Available Background: In the recent past, scrub typhus (ST has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA/indirect immunofluorescence assay (IFA. Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016. All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India. Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA. Chi-square test with Yates correction (Fisher's test was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.

  12. Anthrax blood test

    Science.gov (United States)

    Anthrax serology test; Antibody test for anthrax; Serologic test for B. anthracis ... This test may be performed when the health care provider suspects you have anthrax infection. The bacteria that cause ...

  13. Socioepidemiological screening of serologically ineligible blood donors due to Chagas disease for the definition of inconclusive cases

    Directory of Open Access Journals (Sweden)

    Márcia M Ferreira-Silva

    2010-09-01

    Full Text Available Epidemiological screening combined with serological tests has become an important tool at blood banks for the characterization of donors with or without Trypanosoma cruzi infection. Thus, the objective of the present study was to describe the sociodemographic and epidemiological characteristics of blood donors with non-negative serology for T. cruzito determine possible risk factors associated with serological ineligibility. Sociodemographic and epidemiological data were collected by analysis of patient histories and interviews. The data were analyzed descriptively using absolute and relative frequencies and odds ratio (OR evaluation. The frequency of serological ineligibility was 0.28%, with a predominance of inconclusive reactions (52% and seropositivity among first-time donors (OR = 607, donors older than 30 years (OR = 3.7, females (OR = 1.9, donors from risk areas (OR = 4 and subjects living in rural areas (OR = 1.7. The risk of seropositivity was higher among donors who had contact with the triatomine vector (OR = 11.7 and those with a family history of Chagas disease (OR = 4.8. The results demonstrate the value of detailed clinical-epidemiological screening as an auxiliary tool for serological definition that, together with more specific and more sensitive laboratory methods, will guarantee a higher efficacy in the selection of donors at blood centres.

  14. Serological diagnosis of paracoccidioidomycosis: high rate of inter-laboratorial variability among medical mycology reference centers.

    Directory of Open Access Journals (Sweden)

    Monica Scarpelli Martinelli Vidal

    2014-09-01

    Full Text Available Serological tests have long been established as rapid, simple and inexpensive tools for the diagnosis and follow-up of PCM. However, different protocols and antigen preparations are used and the few attempts to standardize the routine serological methods have not succeeded.We compared the performance of six Brazilian reference centers for serological diagnosis of PCM. Each center provided 30 sera of PCM patients, with positive high, intermediate and low titers, which were defined as the "reference" titers. Each center then applied its own antigen preparation and serological routine test, either semiquantitative double immunodifusion or counterimmmunoelectrophoresis, in the 150 sera from the other five centers blindly as regard to the "reference" titers. Titers were transformed into scores: 0 (negative, 1 (healing titers, 2 (active disease, low titers and 3 (active disease, high titers according to each center's criteria. Major discordances were considered between scores indicating active disease and scores indicating negative or healing titers; such discordance when associated with proper clinical and other laboratorial data, may correspond to different approaches to the patient's treatment. Surprisingly, all centers exhibited a high rate of "major" discordances with a mean of 31 (20% discordant scores. Alternatively, when the scores given by one center to their own sera were compared with the scores given to their sera by the remaining five other centers, a high rate of major discordances was also found, with a mean number of 14.8 sera in 30 presenting a discordance with at least one other center. The data also suggest that centers that used CIE and pool of isolates for antigen preparation performed better.There are inconsistencies among the laboratories that are strong enough to result in conflicting information regarding the patients' treatment. Renewed efforts should be promoted to improve standardization of the serological diagnosis of PCM.

  15. Meat juice serology for Toxoplasma gondii infection in chickens

    Directory of Open Access Journals (Sweden)

    Alice Vismarra

    2016-01-01

    Full Text Available Toxoplasma gondii is an important foodborne zoonosis. Free-range chickens are at particularly high risk of infection and are also excellent indicators of soil contamination by oocysts. In the present study, hearts of 77 freerange chickens were collected at slaughter. T. gondii meat juice enzyme-linked immunosorbent assay was performed with a commercial kit, following validation with positive controls, from experimentally infected chickens, and negative ones. Out of 77 samples, only 66 gave sufficient meat juice for serology. Of these, 24 (36.4% were positive for T. gondii considering the 5*standard deviation values (calculated on the optical density of negative controls, while all the samples were negative considering sample/positive% values. Parasite-specific polymerase chain reaction was carried out on all samples obtained from heart tissue and none were positive for the presence of T. gondii DNA. Results would suggest that further study on the use of meat juice with a validated serological test to detect T. gondii in chickens could lead to widespread epidemiological studies in this important intermediate host. However, sample collection and test specificity require further evaluation.

  16. Diagnostic Accuracy and Feasibility of Serological Tests on Filter Paper Samples for Outbreak Detection of T.b. gambiense Human African Trypanosomiasis

    Science.gov (United States)

    Hasker, Epco; Lutumba, Pascal; Mumba, Dieudonné; Lejon, Veerle; Büscher, Phillipe; Kande, Victor; Muyembe, Jean Jacques; Menten, Joris; Robays, Jo; Boelaert, Marleen

    2010-01-01

    Control of human African trypanosomiasis (HAT) in the Democratic Republic of Congo is based on mass population screening by mobile teams; a costly and labor-intensive approach. We hypothesized that blood samples collected on filter paper by village health workers and processed in a central laboratory might be a cost-effective alternative. We estimated sensitivity and specificity of micro-card agglutination test for trypanosomiasis (micro-CATT) and enzyme-linked immunosorbent assay (ELISA)/T.b. gambiense on filter paper samples compared with parasitology-based case classification and used the results in a Monte Carlo simulation of a lot quality assurance sampling (LQAS) approach. Micro-CATT and ELISA/T.b. gambiense showed acceptable sensitivity (92.7% [95% CI 87.4–98.0%] and 82.2% [95% CI 75.3–90.4%]) and very high specificity (99.4% [95% CI 99.0–99.9%] and 99.8% [95% CI 99.5–100%]), respectively. Conditional on high sample size per lot (≥ 60%), both tests could reliably distinguish a 2% from a zero prevalence at village level. Alternatively, these tests could be used to identify individual HAT suspects for subsequent confirmation. PMID:20682885

  17. Relationship between ultrasonic pulse velocity test result and ...

    African Journals Online (AJOL)

    Ultrasonic Pulse Velocity test result showed an inverse relationship (of -0.935) with the crushed concrete compressive strength. Correlation test, multiple regression analysis, graphs and visual inspection were used to analyze the results. The conclusion drawn is that there exists a relationship between UPV test results and ...

  18. Mathematics Placement Test: Typical Results with Unexpected Outcomes

    Science.gov (United States)

    Ingalls, Victoria

    2011-01-01

    Based on the results of a prior case-study analysis of mathematics placement at one university, the mathematics department developed and piloted a mathematics placement test. This article describes the implementation process for a mathematics placement test and further analyzes the test results for the pilot group. As an unexpected result, the…

  19. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  20. Comparação de dois testes de neutralização, utilizados no diagnóstico sorológico do vesiculovírus Piry Comparison of two neutralization test for the use in the Piry serologic vesiculovirus diagnose

    Directory of Open Access Journals (Sweden)

    José Tavares-Neto

    1993-10-01

    Full Text Available Realizou-se inquérito sorológico para pesquisar anticorpos neutralizantes contra o vesiculovírus Piry, na cidade de Catolândia-Bahia-Brasil. Duas técnicas de vírus-neutralização foram comparadas em cultura das células C6/36, com revelação pelo método imunoenzimático ( TN-C6/36 e em camundongos recém-nascidos (TN-camundongos, que é considerada a prova maior. Em 204 soros, dos 1 .274 colhidos, a concordância das duas técnicas foi de 98,7% (K= 0,9853. Com este resultado do TN-C6/36, que também é mais exeqüível, decidiu-se desenvolver o estudo soro-epidemiológico do vesiculovírus Piry, em Catolândia, baseado nesta nova técnica.A serological survey of Piry was undertaken of the sera of inhabitants of Catolância - Bahia State, Brazil. Serum results obtained by a vesiculovirus neutralization test of C6/36 cells read by ELISA are compared with those obtained by the classic technique, carried out on newbom mice. The agreement between the results was as high as 98.7% of the 204 sera tested and the neutralization test of C6/36 cells was chosen as the most suitable technique for the sero-survey testing.

  1. Public health consequences of a false-positive laboratory test result for Brucella--Florida, Georgia, and Michigan, 2005.

    Science.gov (United States)

    2008-06-06

    Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.

  2. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  3. Legal provisions governing the acknowledgment of test results

    International Nuclear Information System (INIS)

    Strecker, A.

    1982-01-01

    The legal provisions governing the acknowledgment of test results are most frequently applied by administrative orders (design and qualification approvals or specimen testing and approval) and are thus claimable and voidable in accordance with general administrative law. The acknowledgment of test certificates requires a legal basis. Test results, however, can be acknowledged also by administrative bodies. Recently, the Federal Government began to delegate more of its legal authority in this field to private institutions, allowing test results to be acknowledged and test certificates to be issued by government controlled private institutions. (orig.) [de

  4. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  5. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  6. Results from the 2013 drug and alcohol testing survey.

    Science.gov (United States)

    2015-12-01

    This report summarizes the results of the 2013 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) that test positive fo...

  7. Results from the 2008 Drug and Alcohol Testing Survey

    Science.gov (United States)

    2010-01-01

    This report summarizes the results of the 2008 Federal Motor Carrier Safety Administration Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses who test positive for controlled sub...

  8. Experimental test results of multi-channel test rig of T1 test section, 5

    International Nuclear Information System (INIS)

    Hino, Ryutaro; Takase, Kazuyuki; Miyamoto, Yoshiaki

    1990-09-01

    Channel blockage test on a fuel column of the high temperature engineering test reactor (HTTR) has been performed under the helium gas atmosphere at a high temperature and a high pressure in order to obtain safety data on flow rate and temperature distributions in the fuel column with the multi-channel test rig of the fuel stack test section (T 1 ) in HENDEL. In the test, one of 12 fuel channels was blockaded to 90% of flow area at the channel inlet. Experimental results showed that the helium gas flow rate in the blockaded channel was 28%∼33% lower than the average flow rate for Reynolds number from 2300 to 14000 in isothermal flow. When simulated fuel rods were heated, the flow rate in the blockaded channel did not decrease down in comparison with the isothermal flow. This is due to that the heat generated in the fuel rods conducts to the other fuel channels in graphite fuel blocks, so that accelerated pressure losses in the fuel channels change with helium gas temperatures. (author)

  9. Utilization of serology for the diagnosis of suspected Lyme borreliosis in Denmark: Survey of patients seen in general practice

    Directory of Open Access Journals (Sweden)

    Skarphedinsson Sigurdur

    2010-11-01

    Full Text Available Abstract Background Serological testing for Lyme borreliosis (LB is frequently requested by general practitioners for patients with a wide variety of symptoms. Methods A survey was performed in order to characterize test utilization and clinical features of patients investigated for serum antibodies to Borrelia burgdorferi sensu lato. During one calendar year a questionnaire was sent to the general practitioners who had ordered LB serology from patients in three Danish counties (population 1.5 million inhabitants. Testing was done with a commercial ELISA assay with purified flagella antigen from a Danish strain of B. afzelii. Results A total of 4,664 patients were tested. The IgM and IgG seropositivity rates were 9.2% and 3.3%, respectively. Questionnaires from 2,643 (57% patients were available for analysis. Erythema migrans (EM was suspected in 38% of patients, Lyme arthritis/disseminated disease in 23% and early neuroborreliosis in 13%. Age 0-15 years and suspected EM were significant predictors of IgM seropositivity, whereas suspected acrodermatitis was a predictor of IgG seropositivity. LB was suspected in 646 patients with arthritis, but only 2.3% were IgG seropositive. This is comparable to the level of seropositivity in the background population indicating that Lyme arthritis is a rare entity in Denmark, and the low pretest probability should alert general practitioners to the possibility of false positive LB serology. Significant predictors for treating the patient were a reported tick bite and suspected EM. Conclusions A detailed description of the utilization of serology for Lyme borreliosis with rates of seropositivity according to clinical symptoms is presented. Low rates of seropositivity in certain patient groups indicate a low pretest probability and there is a notable risk of false positive results. 38% of all patients tested were suspected of EM, although this is not a recommended indication due to a low sensitivity of

  10. Serologic evidence of exposure to Rift Valley fever virus detected in Tunisia

    Directory of Open Access Journals (Sweden)

    A. Bosworth

    2016-01-01

    Full Text Available Rift Valley fever virus (RVFv is capable of causing dramatic outbreaks amongst economically important animal species and is capable of causing severe symptoms and mortality in humans. RVFv is known to circulate widely throughout East Africa; serologic evidence of exposure has also been found in some northern African countries, including Mauritania. This study aimed to ascertain whether RVFv is circulating in regions beyond its known geographic range. Samples from febrile patients (n=181 and nonfebrile healthy agricultural and slaughterhouse workers (n=38 were collected during the summer of 2014 and surveyed for exposure to RVFv by both serologic tests and PCR. Of the 219 samples tested, 7.8% of nonfebrile participants showed immunoglobulin G reactivity to RVFv nucleoprotein and 8.3% of febrile patients showed immunoglobulin M reactivity, with the latter samples indicating recent exposure to the virus. Our results suggest an active circulation of RVFv and evidence of human exposure in the population of Tunisia.

  11. Brucellosis in Yellowstone National Park bison: Quantitative serology and infection

    Science.gov (United States)

    Roffe, T.J.; Rhyan, Jack C.; Aune, K.; Philo, L.M.; Ewalt, D.R.; Gidlewski, T.; Hennager, S.G.

    1999-01-01

    We collected complete sets of tissues, fluids, and swabs (approx 30) from 37 Yellowstone National Park (YNP) female bison (Bison bison) killed as a result of management actions by the Montana Department of Livestock and YNP personnel. Our goal was to establish the relation between blood tests demonstrating an animal has antibody to Brucella and the potential of that animal to be infected during the second trimester of pregnancy, the time when most management actions are taken. Twenty-eight of the 37 bison were seropositive adults (27) or a seropositive calf (1). We cultured samples using macerated whole tissues plated onto 4 Brucella-selective media and incubated with added CO2 for 1 week. Specimens from 2 adult seropositive females were contaminated, thus eliminating them from our data. Twelve of the remaining 26 seropositive adult and calf female bison (46%) were culture positive for Brucella abortus from 1 or more tissues. Culture positive adult females had high serologic titers. All 11 adults measured 3+ at 1:40 for 10 of 11 (91%) animals. All culture positive female adults had either a PCFIA ???0.080 or a CF reaction ???4+ at 1:80. However 5 (36%) bison with high titers were culture negative for B. abortus. Our findings on the relation between Brucella serology and culture are similar to those reported from studies of chronically infected cattle herds.

  12. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  13. Molecular and Serological Survey of Selected Viruses in Free-Ranging Wild Ruminants in Iran.

    Directory of Open Access Journals (Sweden)

    Farhid Hemmatzadeh

    Full Text Available A molecular and serological survey of selected viruses in free-ranging wild ruminants was conducted in 13 different districts in Iran. Samples were collected from 64 small wild ruminants belonging to four different species including 25 Mouflon (Ovis orientalis, 22 wild goat (Capra aegagrus, nine Indian gazelle (Gazella bennettii and eight Goitered gazelle (Gazella subgutturosa during the national survey for wildlife diseases in Iran. Serum samples were evaluated using serologic antibody tests for Peste de petits ruminants virus (PPRV, Pestiviruses [Border Disease virus (BVD and Bovine Viral Diarrhoea virus (BVDV], Bluetongue virus (BTV, Bovine herpesvirus type 1 (BHV-1, and Parainfluenza type 3 (PI3. Sera were also ELISA tested for Pestivirus antigen. Tissue samples including spleen, liver, lung, tonsils, mesenteric and mediastinal lymph nodes and white blood cells (WBCs were tested using polymerase chain reaction (PCR for PPRV, Foot and Mouth Disease virus (FMDV, Pestivirus, BTV, Ovine herpesvirus type 2 (OvHV-2 and BHV-1. Serologic tests were positive for antibodies against PPRV (17%, Pestiviruses (2% and BTV (2%. No antibodies were detected for BHV-1 or PI3, and no Pestivirus antigen was detected. PCR results were positive for PPRV (7.8%, FMDV (11%, BTV (3%, OvHV-2 (31% and BHV-1 (1.5%. None of the samples were positive for Pestiviruses.

  14. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  15. First TBEV serological screening in Flemish wild boar

    Directory of Open Access Journals (Sweden)

    Sophie Roelandt

    2016-04-01

    Full Text Available In the frame of a Flemish wildlife surveillance in 2013, a serological screening was performed on sera from wild boar (Sus scrofa; n=238 in order to detect tick-borne encephalitis virus (TBEV-specific antibodies. Neutralising antibodies were titrated with a seroneutralisation test (SNT, using two cut-off titres (1/10–1/15. Seven wild boars were found TBEV-seropositive and showed moderate (>1/15 to high (>1/125 SNT-titres; three individuals had borderline results (1/10–1/15. This study demonstrated the presence of TBEV-specific antibodies in wild boar and highlighted potential TBEV-foci in Flanders. Additional surveillance including direct virus testing is now recommended.

  16. Evaluation of immunochromatographic test (ICT) strips for the serological detection of Babesia bovis and Babesia bigemina infection in cattle from Western Java, Indonesia.

    Science.gov (United States)

    Guswanto, Azirwan; Allamanda, Puttik; Mariamah, Euis Siti; Munkjargal, Tserendorf; Tuvshintulga, Bumduuren; Takemae, Hitoshi; Sivakumar, Thillaiampalam; AbouLaila, Mahmoud; Terkawi, Mohamad Alaa; Ichikawa-Seki, Madoka; Nishikawa, Yoshifumi; Yokoyama, Naoaki; Igarashi, Ikuo

    2017-05-30

    Three types of immunochromatographic test (ICT) strips were prepared for the detection of an antibody response against spherical body protein 4 (SBP-4) of Babesia bovis (bovICT), C-terminal-truncated rhoptry-associated protein 1 (rRAP1/CT17) of B. bigemina (bigICT), and the combination of both proteins (dual-ICT). The evaluation of their performance was conducted using a confirmed positive and negative serum panel for B. bovis and B. bigemina. Together with ELISA, the ICT strips were applied to determine the seroprevalence of bovine babesiosis in Western Java, Indonesia. Among 991 serum samples, 28.4%, 25.3%, and 24.5% of cattle were detected to be seropositive to B. bovis infection using ELISA, bovICT, and dual-ICT, respectively. B. bigemina seropositive was detected in 27.1%, 24.2%, and 22.8% of samples using ELISA, bigICT, and dual-ICT, respectively. The comparison of ICT strips and ELISA results using field serum samples showed good agreement with Kappa values >0.7 between all methods The application of ICT strips is preferable in the field situations where rapid diagnosis is required. Furthermore, the data showed the current seroprevalence of bovine babesiosis in Western Java, Indonesia, and efficient control strategies are needed to reduce economic losses due to the disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Serological comparison of selected isolates of Aeromonas salmonicida ssp. Salmonicida

    Science.gov (United States)

    Hahnel, G.B.; Gould, R.W.; Boatman, E.S.

    1983-01-01

    Eight isolates of Acronionus salmonicida ssp. salmonicida were collected during furunculosis epizootics in North American Pacific coast states and provinces. Both virulent and avirulent forms of each isolate, confirmed by challenge and electron microscopy, were examined. Serological comparisons by cross-absorption agglutination tests revealed no serological differences between isolates. Using the double diffusion precipitin test, a single band was observed when antigen from a sonicated virulent strain was reacted with antiserum against a sonicated, virulent strain absorbed with homologous, avirulent strain. The presence of the single band was eliminated by excess sonication.

  18. Melter operation results in chemical test at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Kanehira, Norio; Yoshioka, Masahiro; Muramoto, Hitoshi; Oba, Takaaki; Takahashi, Yuji

    2005-01-01

    Chemical Test of the glass melter system of the Vitrification Facility at Rokkasho Reprocessing Plant (RRP) was performed. In this test, basic performance of heating-up of the melter, melting glass, pouring glass was confirmed using simulated materials. Through these tests and operation of all modes, good results were gained, and training of operators was completed. (author)

  19. The Dornier 328 Acoustic Test Cell (ATC) for interior noise tests and selected test results

    Science.gov (United States)

    Hackstein, H. Josef; Borchers, Ingo U.; Renger, Klaus; Vogt, Konrad

    1992-01-01

    To perform acoustic studies for achieving low noise levels for the Dornier 328, an acoustic test cell (ATC) of the Dornier 328 has been built. The ATC consists of a fuselage section, a realistic fuselage suspension system, and three exterior noise simulation rings. A complex digital 60 channel computer/amplifier noise generation system as well as multichannel digital data acquisition and evaluation system have been used. The noise control tests started with vibration measurements for supporting acoustic data interpretation. In addition, experiments have been carried out on dynamic vibration absorbers, the most important passive noise reduction measure for low frequency propeller noise. The design and arrangement of the current ATC are presented. Furthermore, exterior noise simulation as well as data acquisition are explained. The most promising results show noise reduction due to synchrophasing and dynamic vibration absorbers.

  20. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  1. Results and Analysis from Space Suit Joint Torque Testing

    Science.gov (United States)

    Matty, Jennifer

    2010-01-01

    This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.

  2. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  3. Goat farm management and Brucella serological test among goat keepers and livestock officers, 2011-2012, Nakhon Si Thammarat Province, southern Thailand.

    Science.gov (United States)

    Te-Chaniyom, Thanidtha; Geater, Alan F; Kongkaew, Wandee; Chethanond, Usa; Chongsuvivatwong, Virasakdi

    2016-12-01

    Brucellosis, a zoonotic disease particularly affecting goats, emerged in Thailand in 2003, resulting in both an occupational hazard for goat keepers and livestock officers, and production losses. Farm management practices have been identified as risk factors associated with Brucella sero-positivity in many studies. Our finding in this study should be considered in order to strengthen the system of biosecurity control in farm animals as one health approach. The objectives of the study were to describe the distribution of potential risk factors by types of goat farms and to document the prevalence of human Brucella sero-positivity among goat keepers and livestock officers in Nakhon Si Thammarat, Thailand. A cross-sectional study was conducted from September to December 2012. The study population included three types of goat farms: standard, community enterprise and private goat farms that were located in Nakhon Si Thammmarat Province in southern Thailand. Information on whether the farm had any Brucella sero-positivity goats since 2011 was retrieved from the local livestock office records. Information on farming management was also traced back to 2011. Field researchers collected information from goat keepers of the selected farms using a structured questionnaire. Goat keepers on all farms pre-identified (January to June 2012) as having had at least one positive goat were considered to have been exposed. Goat keepers on a random sample of farms having all goats with negative results were considered to be unexposed. Venous blood samples were collected from goat keepers exposed and unexposed and from livestock officers and the samples were tested by IgG ELISA. Statistical analysis was done under the complex survey design in R software. Fourteen standard farms, 66 community enterprise farms and 68 private farms participated in the study; 82.4% (122/148) used public pasture and 53.4% (79/148) shared breeder goats with other farms. Farm management practices corresponding

  4. Evaluation of LLTR series II test A-7 results

    International Nuclear Information System (INIS)

    Knittle, D.E.; Amos, J.C.; Yang, T.M.

    1981-09-01

    This report evaluates the test A-7 data and assesses the capability of the analytical methodology (as a result of Series I program) to predict the thermal/hydraulic phenomena associated with a large SWR event occurring after the sodium system pressure has increased to near the rupture disc burst pressure due to a smaller size leak event. Evaluation of intertest examination data to determine the extent of test article damage resulting from test A-7 is also included

  5. Test beam results from the D0 end electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Roe, N.A.

    1991-11-01

    Test beam results are presented for the DO end electromagnetic calorimeter. Data were taken with electrons and pions ranging in energy from 5 GeV to 150 GeV. Results from the analysis of the test beam data are presented on energy resolution and linearity, stability and uniformity of response, position resolution and electron-pion separation

  6. Systematic screening for novel, serologically reactive Hepatitis E Virus epitopes

    Directory of Open Access Journals (Sweden)

    Osterman Andreas

    2012-01-01

    Full Text Available Abstract Background The National Institutes of Health classified Hepatitis E as an emerging disease since Hepatitis E Virus (HEV is the major cause of acute hepatitis in developing countries. Interestingly, an increasing number of sporadic cases of HEV infections are described in industrialized countries as zoonosis from domestic livestock. Despite the increasing relevance of this pathogen in clinical virology, commercial antibody assays are mainly based on fragments of HEV open reading frame (ORF 2 and ORF3. The largest ORF1 (poly-protein, however, is not part of current testing formats. Methods From a synthesized full length HEV genotype 1 cDNA-bank we constructed a complete HEV gene library consisting of 15 respective HEV ORF domains. After bacterial expression and purification of nine recombinant HEV proteins under denaturating conditions serum profiling experiments using 55 sera from patients with known infection status were performed in microarray format. SPSS software assessed the antigenic potential of these nine ORF domains in comparison to seven commercial HEV antigens (genotype 1 and 3 by performing receiver operator characteristics, logistic regression and correlation analysis. Results HEV antigens produced with our method for serum profiling experiments exhibit the same quality and characteristics as commercial antigens. Serum profiling experiments detected Y, V and X domains as ORF1-antigens with potentially comparable diagnostic significance as the well established epitopes of ORF2 and ORF3. However no obvious additional increase in sensitivity or specificity was achieved in diagnostic testing as revealed by bioinformatic analysis. Additionally we found that the C-terminal domain of the potential transmembrane protein ORF3 is responsible for IgG and IgM seroreactivity. Data suggest that there might be a genotype specific seroreactivity of homologous ORF2-antigens. Conclusions The diagnostic value of identified ORF1 epitopes might

  7. Swine cysticercosis in the Karangasem district of Bali, Indonesia: An evaluation of serological screening methods.

    Science.gov (United States)

    Swastika, Kadek; Dharmawan, Nyoman Sadra; Suardita, I Ketut; Kepeng, I Nengah; Wandra, Toni; Sako, Yasuhito; Okamoto, Munehiro; Yanagida, Tetsuya; Sasaki, Mizuki; Giraudoux, Patrick; Nakao, Minoru; Yoshida, Takahiko; Eka Diarthini, Luh Putu; Sudarmaja, I Made; Purba, Ivan Elisabeth; Budke, Christine M; Ito, Akira

    2016-11-01

    A serological assessment was undertaken on pigs from the Kubu and Abang sub-districts of Karangasem on the island of Bali, Indonesia, where earlier studies had detected patients with cysticercosis. Antigens purified from Taenia solium cyst fluid by cation-exchange chromatography were used to evaluate antibody responses in the pigs and the serological tests were also evaluated using sera from pigs experimentally infected with T. solium eggs. A total of 392 serum samples from naturally exposed pigs were tested using an ELISA that could be read based on both a colour change perceptible by the naked eye and an ELISA based on absorbance values. Twenty six (6.6%) pigs were found seropositive by the naked-eye ELISA and were categorized into three groups: strongly positive (absorbance values >0.8, n=6), moderately positive (absorbance values between 0.2 and 0.8, n=7), and weakly positive (absorbance values Bali were tested using the same ELISA. All 60 pigs were seronegative with no evidence of Taenia infection at necropsy. The results confirm the presence of porcine cysticercosis on Bali and, while the serological responses seen in T. solium infected animals were much stronger than those infected with T. hydatigena, the diagnostic antigens are clearly not species specific. Further studies are necessary to confirm if it is possible to draw a cut off line for differentiation of pig infected with T. solium from those infected with T. hydatigena. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Results of Detailed Hydrologic Characterization Tests - Fiscal Year 2000

    International Nuclear Information System (INIS)

    Spane, Frank A; Thorne, Paul D; Newcomer, Darrell R

    2001-01-01

    This report provides the results of detailed hydrologic characterization tests conducted within eleven Hanford Site wells during fiscal year 2000. Detailed characterization tests performed included groundwater-flow characterization; barometric response evaluation; slug tests; single-well tracer tests; constant-rate pumping tests; and in-well, vertical flow tests. Hydraulic property estimates obtained from the detailed hydrologic tests include transmissivity; hydraulic conductivity; specific yield; effective porosity; in-well, lateral flow velocity; aquifer-flow velocity; vertical distribution of hydraulic conductivity (within the well-screen section); and in-well, vertical flow velocity. In addition, local groundwater-flow characteristics (i.e., hydraulic gradient and flow direction) were determined for four sites where detailed well testing was performed

  9. Early results of gate valve flow interruption blowdown tests

    International Nuclear Information System (INIS)

    DeWall, K.G.

    1988-01-01

    The preliminary results of the USNRC/INEL high-energy BWR line break flow interruption testing are presented. Two representative nuclear valve assemblies were cycled under design basis Reactor Water Cleanup pipe break conditions to provide input for the technical basis for resolving the Nuclear Regulatory Commission's Generic Issue 87. The effects of the blowdown hydraulic loadings on valve operability, especially valve closure stem forces, were studied. The blowdown tests showed that, given enough thrust, typical gate valves will close against the high flow resulting from a line break. The tests also showed that proper operator sizing depends on the correct identification of values for the sizing equation. Evidence exists that values used in the past may not be conservative for all valve applications. The tests showed that improper operator lock ring installation following test or maintenance can invalidate in-situ test results and prevent the valve from performing its design function. 2 refs., 12 figs., 2 tabs

  10. Serological monitoring of ornitobacteriosis in broilers in South Banat district

    Directory of Open Access Journals (Sweden)

    Gavrilović Pavle

    2014-01-01

    Full Text Available Ornithobacterium rhinotracheale is a relatively recently discovered bacterium and its role in the pathology of avian respiratory infections has not yet been clarified. Since there was no data relating to the prevalence of this infection in Serbia at the time of carrying out our investigations, we decided to explore the prevalence of the infection in broilers and its influence on clinical manifestations at the selected apizootiological area with developed poultry industry. A total of 430 blood samples from 26 flocks of broilers of different ages, from five municipalities were taken for examination. The serum samples were tested by ELISA for the presence of specific antibodies to the agent. Epizootiological investigation was carried out based on the results obtained with serological testing and epizootiological data, collected from the farms. The data were analyzed statistically to identify association between the infection and manifestation of clinical symptoms by Fisher’s exact test. Seropositive chickens were detected in 16 out of 26 examined broiler flocks at the age of 3 to 56 days. The percentage of seropositive samples per flock was 5-30%. The titer values of specific antibodies ranged from 946 to 6886. Serological response to O. rhinotracheale was evidenced in five flocks which had clinical symptoms in the form of respiratory tract disorders or stunting. However, specific antibodies against the agent were discovered in 11 flocks which did not show clinical symptoms. Statistical analysis revealed no association between the presence of infection and the appearance of clinical symptoms (p = 0.1213. The results are in agreement with those of other authors who investigated the prevalence of this infection and its manifestations in other countries. The present investigation determined indirectly, serologically a presence of O. rhinotracheale in the majority of examined broiler flocks (61,54% and a small average number of individual

  11. Optimization and evaluation of an influenza A (H5) pseudotyped lentiviral particle-based serological assay

    NARCIS (Netherlands)

    Garcia, Jean-Michel; Lagarde, Nadège; Ma, Edward S. K.; de Jong, Menno D.; Peiris, J. S. Malik

    2010-01-01

    BACKGROUND: Novel serological methods provide alternative options for sero-diagnosis, sero-epidemiology and for determining evidence of naturally acquired or vaccine induced immunity. Micro-neutralization tests are currently the gold standard for serological studies of highly pathogenic avian

  12. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  13. Relationship between substances in seminal plasma and Acrobeads Test results.

    Science.gov (United States)

    Komori, Kazuhiko; Tsujimura, Akira; Okamoto, Yoshio; Matsuoka, Yasuhiro; Takao, Tetsuya; Miyagawa, Yasushi; Takada, Shingo; Nonomura, Norio; Okuyama, Akihiko

    2009-01-01

    To asses the effects of seminal plasma on sperm function. Retrospective case-control study. University hospital. One hundred fourteen infertile men. Acrobeads Test scores (0-4) and measurement of interleukin (IL)-6, soluble IL-6 receptor, epidermal growth factor, insulin-like growth factor-I (IGF-I), transforming growth factor-beta I, superoxide dismutase, calcitonin, and macrophage migration inhibitory factor (MIF) levels in seminal plasma. Kruskal-Wallis test to compare the concentrations of substances as a nonparametric test for differences among Acrobeads Test scores and a multivariable logistic regression model to find independent risk factors associated with abnormal Acrobeads Test results. The Acrobeads Test score was 0 for 7 samples, 1 for 20 samples, 2 for 18 samples, 3 for 28 samples, and 4 for 41 samples. Age, abstinence period, and semen parameters, except for sperm motility and percentage of sperm with abnormal morphology, had no effect on the Acrobeads Test results. Concentrations of IGF-I and MIF were significantly higher in patients with abnormal Acrobeads Test results. Multivariate analysis indicated that MIF and IGF-I were significantly associated with abnormal Acrobeads Test results (scores 0 to 1). Although further studies are needed, IGF-I and MIF in seminal plasma may have negative effects on sperm function.

  14. An indirect haemagglutination test for demonstration of gonococcal antibodies using gonococcal pili as antigen. II. Serological investigation of patients attending a dermato-venereological outpatients clinic in Copenhagen

    DEFF Research Database (Denmark)

    Reimann, K; Lind, I; Andersen, Klaus Ejner

    1980-01-01

    A total of 1223 serum specimens were obtained from 649 consecutive patients attending a dermatovenereological out-patient clinic in Copenhagen with a request for venereal disease control. The sera were examined for gonococcal antibodies by both a gonococcal complement fixation test (GCF) and an i...

  15. Bovine and Caprine Brucellosis in Bangladesh: Bayesian evaluation of four serological tests, true prevalence, and associated risk factors in household animals.

    Science.gov (United States)

    Ahasan, Md Shamim; Rahman, Md Siddiqur; Rahman, A K M Anisur; Berkvens, Dirk

    2017-01-01

    A cross-sectional study was carried out to estimate the true prevalence of Brucella spp. and identify allied risk factors/indicators associated with brucellosis in the Dinajpur and Mymensingh districts of Bangladesh. A total 320 stratified random blood samples were collected and tested in parallel for Brucella antibodies using Rose Bengal (RBT), slow agglutination (SAT), and indirect and competitive ELISA. In addition, a structured questionnaire was administered to each household herd owner to gather information regarding potential risk factors. Both univariate and multivariate logistic regression analyses were used to identify potential risk factors or indicators at animal level. A Bayesian approach was used to estimate the true prevalence of brucellosis along with the test performances (Se and Sp). The estimated animal level true prevalence in cattle was 9.70 % (95 % CPI 5.0-16 %) and in goat 6.3 % (95 % CPI 2.8-11.0 %). The highest sensitivity was achieved by SAT ranges from 69.6 to 78.9 %, and iELISA was found to be more specific (97.4 to 98.8 %) in comparison with other tests. On the other hand, a significant level of (P tests can be recommended to apply alone for the diagnosis of bovine and caprine brucellosis.

  16. Results of recent KROTOS FCI tests. Alumina vs. corium melts

    Energy Technology Data Exchange (ETDEWEB)

    Huhtiniemi, I.; Magallon, D.; Hohmann, H. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    Recent results from KROTOS fuel-coolant interaction experiments are discussed. Five tests with alumina were performed under highly subcooled conditions, all of these tests resulted in spontaneous steam explosions. Additionally, four tests were performed at low subcooling to confirm, on one hand, the suppression of spontaneous steam explosions under such conditions and, on the other hand, that such a system is still triggerable using an external initiator. The other test parameters in these alumina tests included the melt superheat and the initial pressure. All the tests in the investigated superheat range (150 K - 750 K) produced a steam explosion and no evidence of the explosion suppression by the elevated initial pressure (in the limited range of 0.1 - 0.375 MPa) was observed in the alumina tests. The corium test series include a test with 3 kg of melt under both subcooled and near saturated conditions at ambient pressure. Two additional tests were performed with subcooled water; one test was performed at an elevated pressure of 0.2 MPa with 2.4 kg of melt and another test with 5.1 kg of melt at ambient pressure. None of these tests with corium produced a propagating energetic steam explosion. However, propagating low energy (about twice the energy of the trigger pulse) events were observed. All corium tests produced significantly higher water level swells during the mixing phase than the corresponding alumina tests. Present experimental evidence suggests that the water depletion in the mixing zone suppresses energetic steam explosions with corium melts at ambient pressure and in the present pour geometry. Processes that could produce such a difference in void generation are discussed. (author)

  17. Serological Susceptibility to Varicella Among U.S. Immigration and Customs Enforcement Detainees.

    Science.gov (United States)

    Varan, Aiden K; Lederman, Edith R; Stous, Shanon S; Elson, Diana; Freiman, Jennifer L; Marin, Mona; Lopez, Adriana S; Stauffer, William M; Joseph, Rachael H; Waterman, Stephen H

    2018-01-01

    U.S. Immigration and Customs Enforcement (ICE) is responsible for detaining unauthorized aliens during immigration proceedings. During 2014 to 2015, adult ICE detainees at a California facility were invited to complete a survey concerning self-reported varicella history and risk factors. Participants underwent serological testing for varicella-zoster virus (VZV) IgG; susceptible individuals were offered varicella vaccination. Among 400 detainees with available serology results, 48 (12%) were susceptible to varicella. Self-reported varicella history was negatively associated with susceptibility (adjusted odds ratio = 0.16; 95% confidence interval [0.07, 0.35]). Among 196 detainees reporting a positive history, 95% had VZV IgG levels suggestive of varicella immunity. Among 44 susceptible detainees offered vaccination, 86% accepted. Given relatively high varicella susceptibility, targeted screening and vaccination among ICE detainees lacking a positive history might reduce varicella transmission risks.

  18. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  19. Thermal results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Tada, Eisuke; Hiyama, Tadao; Kato, Takashi; Takahashi, Osamu; Shimamoto, Susumu

    1984-01-01

    This paper describes thermal results obtained in the domestic test of the Japanese LCT coil which was constructed at the Japan Atomic Energy Research Institute (JAERI) in order to develop large superconducting coils for fusion in international collaboration proposed by the IEA. The domestic test was carried out from May 13 to June 17 in 1982 by using the test facility named as SETF (Superconducting Engineering Test Facility) which was composed of a 350-l/h helium cryogenic system, a vacuum system, a 30 KA-DC power supply and protection system, and a PDP-11/70 computer system. The cool-down characteristics, heat load, fast discharge characteristics, stability, and warm-up characteristics of the LCT coil were successfully measured in the test. The details of thermal test results acquired in the cool-down, heat load measurement, fast discharge, and warm-up, and the comparison between measurements and calculations are described in this paper. (author)

  20. Positive serology for viral hepatitis and donor self-exclusion in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Julia De Luca Maccarini

    2013-07-01

    Full Text Available Introduction Despite the great advances in serological testing for transfusion-transmitted infections, the selection of blood donors by blood bank operators remains the only way to avoid transmission within the testing window period. Part of this selection is the self-exclusion form, on which the donors can exclude their blood from donation without any explanation. This study assessed the clinical and epidemiological characteristics related to positivity for viral hepatitis and to the use of the confidential self-exclusion (CSE form. Methods This transversal study analyzed the data collected from blood donors' files in a hospital in Southern Brazil. Univariate and multivariate analyses identified the clinical and epidemiological variables related to positive serologies of viral hepatitis and to whether the donor was self-excluded. Results Of the 3,180 donors included in this study, 0.1% tested positive for HBsAg, 2.1% for anti-HBc, and 0.9% for anti-HCV. When the 93 donors with positive serologies for viral hepatitis were compared with those who were negative, a greater proportion of the positive serology group was found to have had a history of blood transfusions (OR=4.908; 95%CI=1.628 - 14.799; p<0.01, had repeatedly donated (OR=2.147; 95%CI=1.236 - 3.729; p<0.01, and used the CSE form for self-exclusion (OR=7.139; 95%CI=2.045 - 24.923; p<0.01. No variables were independently associated with self-exclusion. Conclusions A history of blood transfusion, repeated donations, and self-exclusion are factors that should be considered during viral hepatitis screenings in blood banks.

  1. Serological evidence of influenza A viruses in frugivorous bats from Africa.

    Directory of Open Access Journals (Sweden)

    Gudrun Stephanie Freidl

    Full Text Available Bats are likely natural hosts for a range of zoonotic viruses such as Marburg, Ebola, Rabies, as well as for various Corona- and Paramyxoviruses. In 2009/10, researchers discovered RNA of two novel influenza virus subtypes--H17N10 and H18N11--in Central and South American fruit bats. The identification of bats as possible additional reservoir for influenza A viruses raises questions about the role of this mammalian taxon in influenza A virus ecology and possible public health relevance. As molecular testing can be limited by a short time window in which the virus is present, serological testing provides information about past infections and virus spread in populations after the virus has been cleared. This study aimed at screening available sera from 100 free-ranging, frugivorous bats (Eidolon helvum sampled in 2009/10 in Ghana, for the presence of antibodies against the complete panel of influenza A haemagglutinin (HA types ranging from H1 to H18 by means of a protein microarray platform. This technique enables simultaneous serological testing against multiple recombinant HA-types in 5 μl of serum. Preliminary results indicate serological evidence against avian influenza subtype H9 in about 30% of the animals screened, with low-level cross-reactivity to phylogenetically closely related subtypes H8 and H12. To our knowledge, this is the first report of serological evidence of influenza A viruses other than H17 and H18 in bats. As avian influenza subtype H9 is associated with human infections, the implications of our findings from a public health context remain to be investigated.

  2. Commissioning and First Results from the Fermilab Cryomodule Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; et al.

    2017-05-01

    A new test stand dedicated to SRF cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

  3. Sims Prototype System 2 test results: Engineering analysis

    Science.gov (United States)

    1978-01-01

    The testing, problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype System, 2, solar hot water system, at the Marshall Space Flight Center Solar Test Facility was described. System 2 is a liquid, non draining solar energy system for supplying domestic hot water to single residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.

  4. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C. Edward; Klee, Paul M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  5. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  6. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  7. 7 CFR 91.24 - Reports of test results.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Reports of test results. 91.24 Section 91.24 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS...

  8. [Serological and cellular reactivity to mycobacterial proteins in Hansen's disease].

    Science.gov (United States)

    Rada, Elsa; Aranzazu, Nacarid; Rodríguez, Vestalia; Borges, Rafael; Convit, Jacinto

    2010-09-01

    The study was designed for evaluating immunological reactivity to various mycobacterial protein preparations using serological and cell-mediated immunological tests in patients with clinical leprosy signs, predominantly, with the multibacillary forms. All patients were adults with ages between 20 and 30 years. Fifty eight (n = 81) percent corresponded to Lepromatous Leprosy (LL), 29% (n = 41) to Borderline Lepromatous Leprosy (BL) and 10% (n = 41) to Borderline Borderline Leprosy (BB); only 3% were Borderline Tuberculoid (BT) patients: 74% males and 26% females. The most frequent reactional phenomenon was of the Erythema Nodosum (ENL) type. The mycobacterial proteins tested were: total crude Mycobacterium leprae antigens (MISA); Mycobacterium bovis (MbSA and excretion MbSA); partially purified excretion protein antigen, with a 30 kDa relative movility (Ml30); and recombinant M. leprae proteins (Mt70, Mb 65, Ml 36, 28, 18 and 10 kDa). Two of the recombinant proteins (Ml10 and Ml 36 kDa) presented a statiscally significant higher serological reactivity, directly related with a larger bacillary load (p = 0.0051 and 0.050 respectively). The 30 kDa protein was predominantly recognized by antibodies from multibacillary patients. Results show that mean antibody values were higher in non reactional patients when tested against complete proteins (MbSA and ex MbSA) when compared with the group of patients who presented reactional phenomena (p = 0.000567 and 0.000061, respectively). Comparing reactional with non reactional patients, it was seen that mean antibody values against complete proteins (MbSA and ex MbSA) were higher in non reactional individuals (p = 0.000567 and 0.000061, respectively). This same behavior occurred towards individual mycobacterial proteins (30, 10 and 36 kDa). The T lymphocyte prolypherative response in reactional and non reactional patients towards mycobacterial proteins (MlSA, Ml 10 kDa, MbSA, ex MbSA) was negative.

  9. Development and evaluation of modern enzyme immunoassays for comprehensive syphilis serology

    NARCIS (Netherlands)

    O.E. IJsselmuiden

    1989-01-01

    textabstractIn the previous Chapters of this dissertation the major shortcomings of the current serological tests for syphilis were investigated. These include an insufficient sensitivity and specificity, reactivity of a diagnostic test long after the syphilitic infection had been

  10. Dengue occurrence relations and serology: cross-sectional analysis of results from the Guerrero State, Mexico, baseline for a cluster-randomised controlled trial of community mobilisation for dengue prevention.

    Science.gov (United States)

    Nava-Aguilera, Elizabeth; Morales-Pérez, Arcadio; Balanzar-Martínez, Alejandro; Rodríguez-Ramírez, Ofelia; Jiménez-Alejo, Abel; Flores-Moreno, Miguel; Gasga-Salinas, David; Legorreta-Soberanis, José; Paredes-Solís, Sergio; Morales-Nava, Pedro Antonio; de Lourdes Soto-Ríos, María; Ledogar, Robert J; Coloma, Joséfina; Harris, Eva; Andersson, Neil

    2017-05-30

    The Mexican arm of the Camino Verde trial of community mobilisation for dengue prevention covered three coastal regions of Guerrero state: Acapulco, Costa Grande and Costa Chica. A baseline cross-sectional survey provided data for community mobilisation and for adapting the intervention design to concrete conditions in the intervention areas. Trained field teams constructed community profiles in randomly selected clusters, based on observation and key informant interviews. In each household they carried out an entomological inspection of water containers, collected information on socio-demographic variables and cases of dengue illness among household members in the last year, and gathered paired saliva samples from children aged 3-9 years, which were subjected to ELISA testing to detect recent dengue infection. We examined associations with dengue illness and recent dengue infection in bivariate and then multivariate analysis. In 70/90 clusters, key informants were unable to identify any organized community groups. Some 1.9% (1029/55,723) of the household population reported dengue illness in the past year, with a higher rate in Acapulco region. Among children 3-9 years old, 6.1% (392/6382) had serological evidence of recent dengue infection. In all three regions, household use of anti-mosquito products, household heads working, and households having less than 5 members were associated with self-reported dengue illness. In Acapulco region, people aged less than 25 years, those with a more educated household head and those from urban sites were also more likely to report dengue illness, while in Costa Chica and Costa Grande, females were more likely to report dengue illness. Among children aged 3-9 years, those aged 3-4 years and those living in Acapulco were more likely to have evidence of recent dengue infection. The evidence from the baseline survey provided important support for the design and implementation of the trial intervention. The weakness of

  11. Power-cooling mismatch test series. Test PCM-2A; test results report

    International Nuclear Information System (INIS)

    Cawood, G.W.; Holman, G.W.; Martinson, Z.R.; Legrand, B.L.

    1976-09-01

    The report describes the results of an in-pile experimental investigation of pre- and postcritical heat flux (CHF) behavior of a single 36-inch-long, pressurized water reactor (PWR) type, UO 2 -fueled, zircaloy-clad fuel rod. The nominal coolant conditions for pressure and temperature were representative of those found in a commercial PWR. Nine separate departures from nucleate boiling (DNB) cycles were performed by either of two different methods: (a) decreasing the coolant flow rate while the fuel rod power was held constant, or (b) increasing the fuel rod power while the coolant flow rate was held constant. DNB was obtained during eight of the nine cycles performed. For the final flow reduction, the mass flux was decreased to 6.1 x 10 5 lb/hr-ft 2 at a constant peak linear heat generation rate of 17.8 kW/ft. The fuel rod was allowed to remain in film boiling for about 210 seconds during this final flow reduction. The fuel rod remained intact during the test. Results of on-line measurements of the fuel rod behavior are presented together with discussion of instrument performance. A comparison of the data with Fuel Rod Analysis Program-Transient 2 (FRAP-T2) computer code calculations is included

  12. Drug and alcohol testing results 2009 annual report

    Science.gov (United States)

    2013-11-01

    This is the 15th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2009, the requirements of the overall drug and alcohol...

  13. Drug and alcohol testing results 2007 annual report

    Science.gov (United States)

    2009-05-01

    This is the 13th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2007, the requirements of the overall drug and alcohol...

  14. Drug and Alcohol Testing Results 2008 Annual Report

    Science.gov (United States)

    2010-09-01

    This is the 14th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing : Program. This report summarizes the reporting requirements for calendar year 2008, the requirements of the overall : drug and alcoh...

  15. Drug and alcohol testing results 2006 annual report.

    Science.gov (United States)

    2008-08-01

    This is the 12th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2006, the requirements of the overall drug and alcohol t...

  16. Results from tests of the Delphi TPC prototype

    International Nuclear Information System (INIS)

    Vilanova, D.

    1985-01-01

    Results from beam tests of a half-scale sector of the Delphi TPC are presented. The spatial resolution is slightly higher than predicted by Monte Carlo simulations, corresponding to an average value of about 300 μm. (orig.)

  17. Test emission of uranium hexafluoride in atmosphere. Results interpretation

    International Nuclear Information System (INIS)

    Crabol, B.; Deville-Cavelin, G.

    1989-01-01

    To permit the modelization of gaseous uranium hexafluoride behaviour in atmosphere, a validation test has been executed the 10 April 1987. The experimental conditions, the main results and a comparison with a diffusion model are given in this report [fr

  18. Interim results from UO2 fuel oxidation tests in air

    International Nuclear Information System (INIS)

    Campbell, T.K.; Gilbert, E.R.; Thornhill, C.K.; White, G.D.; Piepel, G.F.; Griffin, C.W.j.

    1987-08-01

    An experimental program is being conducted at Pacific Northwest Laboratory (PNL) to extend the characterization of spent fuel oxidation in air. To characterize oxidation behavior of irradiated UO 2 , fuel oxidation tests were performed on declad light-water reactor spent fuel and nonirradited UO 2 pellets in the temperature range of 135 to 250 0 C. These tests were designed to determine the important independent variables that might affect spent fuel oxidation behavior. The data from this program, when combined with the test results from other programs, will be used to develop recommended spent fuel dry-storage temperature limits in air. This report describes interim test results. The initial PNL investigations of nonirradiated and spent fuels identified the important testing variables as temperature, fuel burnup, radiolysis of the air, fuel microstructure, and moisture in the air. Based on these initial results, a more extensive statistically designed test matrix was developed to study the effects of temperature, burnup, and moisture on the oxidation behavior of spent fuel. Oxidation tests were initiated using both boiling-water reactor and pressurized-water reactor fuels from several different reactors with burnups from 8 to 34 GWd/MTU. A 10 5 R/h gamma field was applied to the test ovens to simulate dry storage cask conditions. Nonirradiated fuel was included as a control. This report describes experimental results from the initial tests on both the spent and nonirradiated fuels and results to date on the tests in a 10 5 R/h gamma field. 33 refs., 51 figs., 6 tabs

  19. NNWSI Phase II materials interaction test procedure and preliminary results

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1985-01-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) project is investigating the volcanic tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. This report describes a test method (Phase II) that has been developed to measure the release of radionuclides from the waste package under simulated repository conditions, and provides information on materials interactions that may occur in the repository. The results of 13 weeks of testing using the method are presented, and an analog test is described that investigates the relationship between the test method and expected repository conditions. 9 references, 10 figures, 11 tables

  20. Recent test results on the ATLAS SCT detector

    International Nuclear Information System (INIS)

    Pernegger, H.

    2003-01-01

    The ATLAS Semiconductor Tracker (SCT) will be a central part of the tracking system of the ATLAS experiment. The SCT, which is currently under construction, will consist of four concentric barrels of silicon detectors as well as two silicon endcap detectors formed by nine disks each. After an overview of the SCT and the detector module layout, the paper will summarize recent test results obtained from silicon detector modules, which have been extensively tested before starting their large series production. The tests presented here cover electrical performance of individual modules, their performance after irradiation, as well as system tests in a multi-module setup

  1. Preliminary results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Matsumoto, T.; Komine, K.; Arai, S.

    1997-01-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11-12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented

  2. Test results on reuse of reclaimed shower water - A summary

    Science.gov (United States)

    Verostko, Charles E.; Garcia, Rafael; Sauer, Richard; Reysa, Richard P.; Linton, Arthur T.

    1989-01-01

    Results are presented from tests to evaluate a microgravity whole body shower and waste water recovery system design for possible use on the Space Station. Several water recovery methods were tested, including phase change distillation, a thermoelectric hollow fiber membrane evaporation subsystem, and a reverse osmosis dynamic membrane system. Consideration is given to the test hardware, the types of soaps evaluated, the human response to showering with reclaimed water, chemical treatment for microbial control, the procedures for providing hygienic water, and the quality of water produced by the systems. All three of the waste water recovery systems tested successfully produced reclaimed water for reuse.

  3. Structural fatigue test results for large wind turbine blade sections

    Science.gov (United States)

    Faddoul, J. R.; Sullivan, T. L.

    1982-01-01

    In order to provide quantitative information on the operating life capabilities of wind turbine rotor blade concepts for root-end load transfer, a series of cantilever beam fatigue tests was conducted. Fatigue tests were conducted on a laminated wood blade with bonded steel studs, a low cost steel spar (utility pole) with a welded flange, a utility pole with additional root-end thickness provided by a swaged collar, fiberglass spars with both bonded and nonbonded fittings, and, finally, an aluminum blade with a bolted steel fitting (Lockheed Mod-0 blade). Photographs, data, and conclusions for each of these tests are presented. In addition, the aluminum blade test results are compared to field failure information; these results provide evidence that the cantilever beam type of fatigue test is a satisfactory method for obtaining qualitative data on blade life expectancy and for identifying structurally underdesigned areas (hot spots).

  4. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  5. Serological and Virological Study of Newcastle Disease and Avian ...

    African Journals Online (AJOL)

    Serological survey on the prevalence of Newcastle disease (NCD) virus antibodies using haemagglutination inhibition test (HI) and virological detection by RT-PCR of highly pathogenic avian influenza (HPAI) H5N1, were carried out in 6 regions of Senegal from June to November 2008. Rural chickens were raised in free ...

  6. 21 CFR 866.3300 - Haemophilus spp. serological reagents.

    Science.gov (United States)

    2010-04-01

    ... serological tests to identify Haemophilus spp. directly from clinical specimens or tissue culture isolates derived from clinical specimens. The identification aids in the diagnosis of diseases caused by bacteria belonging to the genus Haemophilus and provides epidemiological information on diseases cause by these...

  7. Sklerodermi--systemisk sklerose. Serologi, lungefunktion og overlevelse

    DEFF Research Database (Denmark)

    Ullman, S; Halberg, P; Wiik, A

    1999-01-01

    %, anti-Scl-70 antibodies in 13% and anti-U1-RNP antibodies in 6.5%. These serological groups were associated with limited SSc, diffuse SSc, and myositis/arthritis, respectively. The most prevalent finding at first lung function test was isolated reduction of diffusion capacity (47%). Further...

  8. A Serological Survey for Newcastle Disease Virus Antibobies in ...

    African Journals Online (AJOL)

    Abstract. A serological survey to detect the presence of antibodies to Newcastle disease virus (NDV) in village poultry was conducted in 17 villages of Yobe State, Nigeria. The aim of the study was to investigate the prevalence of NDV using haemaggluttination inhibition test. Ten households were sampled from each village.

  9. 21 CFR 866.3510 - Rubella virus serological reagents.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Serological Reagents § 866.3510 Rubella virus... Clinical Laboratory Standards': (i) 1/LA6 “Detection and Quantitation of Rubella IgG Antibody: Evaluation... Products in the Clinical Laboratory, October 1997,” (ii) 1/LA18 “Specifications for Immunological Testing...

  10. Results of tests with open fuel in KNK II

    International Nuclear Information System (INIS)

    Schmitz, G.

    1987-03-01

    For the operation of Liquid Metal Cooled Fast Breeder Reactors with cladding failures the consequences of increased contamination by fission products and fuel and the possibility of failure propagation to adjacent fuel pins due to fuel swelling have to be envisaged. To clarify some of these problems a KNK II test program involving open fuel was defined with the first experiments of this program being performed between October 1981 and May 1984. After the description of the test equipment and of the test program, the results will be presented on delayed neutron measurements, fission gas measurements and post irradiation examinations. The report will conclude with a discussion of the results [de

  11. Serologic Evaluation of Cornea Donors and Microbiologic Evaluation of Cornea Storage Media in an Eye Bank from Izmir, Turkey.

    Science.gov (United States)

    Palamar, Melis; Degirmenci, Cumali; Sertoz, Ruchan; Aydemir, Sohret; Egrilmez, Sait; Yagci, Ayse

    2017-12-01

    Our objective was to evaluate the serologic positivity of cornea donors and microbiologic positivity of cornea storage media at the Ege University Tissue and Cornea Bank, Izmir, Turkey. We retrospectively investigated the serologic blood sample and microbiological culture media analysis results of all cornea donors at Ege University Tissue and Cornea Bank between 2007 and 2015 with reference to age, sex, and cause of death of each donor. Mean age of the 955 deceased donors was 43.19 ± 15.89 years (range, 2-65 y). The mean postmortem time to blood sample removal and excision of the cornea tissue was 8.4 hours (range, 4-12 h). Serologic analyses showed that 855 donors (89.5%) were seronegative. The remaining donors were seropositive for hepatitis B (54 donors; 5.7%), human immunodeficiency (27 donors; 2.8%), hepatitis C (14 donors; 1.5%), and syphilis (5 donors; 0.5%) virus infections. Microbiologic analyses of the storage media were negative, with no microorganisms shown in 855 samples (89.5%). Candida species (32 donors; 3.4%), Escherichia coli (14 donors; 1.5%), Pseudomonas aeruginosa (11 donors; 1.2%), methicillin-resistant Staphylococcus aureus (11 donors; 1.2%), Enterobacter species (11 donors; 1.2%), Klebsiella pneumoniae (7 donors; 0.7%), Acinetobacter baumannii (6 donors; 0.6%), Proteus species (5 donors; 0.5%), and Corynebacterium species (3 donors; 0.3%) were the detected microorganisms in the infected storage media. False-positive serologic results among cornea donors were high. The incidence of false-positive results might be decreased by earlier blood removal from deceased donors and testing of all potential donors in intensive care units. Although rare, endophthalmitis after keratoplasty might be a devastating problem. In addition to serologic testing, microbiologic analyses of cornea storage media before transplant may be an effective way to prevent postoperative infectious complications.

  12. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  13. Uprated OMS Engine Status-Sea Level Testing Results

    Science.gov (United States)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  14. Cement/bentonite interaction. Results from 16 month laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Karnland, O. [Clay Technology AB, Lund (Sweden)

    1997-12-01

    The work concerns possible bentonite clay mineral alteration in constructions with bentonite in close contact with cement, and the effect of such changes on bentonite buffer properties. The investigation comprises a 16 months laboratory test series with hydrothermal cell tests, percolation tests and diffusion tests. MX-80 Wyoming bentonite was used in all tests. Two types of artificial cement pore water solutions were used in the percolation and diffusion tests. The swelling pressure and the hydraulic conductivity were measured continuously in the percolation tests. After termination, the clay was analyzed with respect to changes in element distribution, mineralogy and shear strength. The water solutions were analyzed with respect to pH, cations and major anions. The results concerning chemical and mineralogical changes are in summary: Ion exchange in the montmorillonite until equilibrium with cement pore-water ions was reached; Increase in cation exchange capacity; Dissolution of original cristobalite; Increase in quartz content; Minor increase in illite content; Minor formation of chlorite; Formation of CSH(I); Wash away of CSH-gel into surrounding water. A large decrease in swelling pressure and a moderate increase in hydraulic conductivity were recorded in the samples percolated by SULFACEM pore-water solution. The mineralogical alterations only concerned a minor part of the total bentonite mass and the changes in physical properties were therefore most likely due to the replacement of the original charge balancing cation by cement pore-water cations. Comparisons between the current test result and results from 4 month tests indicate that the rates of illite and chlorite formation were reduced during the tests. The presence of zeolites in the clay could not be ensured. However, the discovery of CSH material is important since CSH is expected to precede the formation of zeolites 5 refs, 48 figs, 11 tabs

  15. ExEP yield modeling tool and validation test results

    Science.gov (United States)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  16. A comparison of two agar gel immunodiffusion methods and a complement fixation test for serologic diagnosis of Brucella ovis infection in experimentally infected rams

    Directory of Open Access Journals (Sweden)

    M.N. Xavier

    2011-08-01

    Full Text Available A infecção por Brucella ovis é considerada uma das principais causas de epididimite e infertilidade em carneiros, resultando em falhas reprodutivas e perdas econômicas significativas em rebanhos ovinos ao redor do mundo. O estudo teve o objetivo de avaliar três testes sorológicos disponíveis para o diagnóstico da brucelose ovina por B. ovis, utilizando 181 soros ovinos. Amostras de soro provenientes de carneiros experimentalmente infectados foram coletadas ao longo de 192 dias pós-infecção (n=117 e durante o período pré-infecção (n=9. Adicionalmente, amostras de soro foram obtidas de ovinos provenientes de um rebanho livre para B. ovis (n=55. As técnicas de imunodifusão em gel de agar (IDGA, utilizando dois antígenos disponíveis comercialmente, e de fixação de complemento foram comparadas (FC. Foram obtidos resultados de sensibilidade especificidade semelhantes para ambos os métodos de IDGA e ainda, a técnica de IDGA foi mais eficiente do que a da FC para o diagnóstico sorológico da infecção por B. ovis.

  17. Results from Testing of Two Rotary Percussive Drilling Systems

    Science.gov (United States)

    Kriechbaum, Kristopher; Brown, Kyle; Cady, Ian; von der Heydt, Max; Klein, Kerry; Kulczycki, Eric; Okon, Avi

    2010-01-01

    The developmental test program for the MSL (Mars Science Laboratory) rotary percussive drill examined the e ect of various drill input parameters on the drill pene- tration rate. Some of the input parameters tested were drill angle with respect to gravity and percussive impact energy. The suite of rocks tested ranged from a high strength basalt to soft Kaolinite clay. We developed a hole start routine to reduce high sideloads from bit walk. The ongoing development test program for the IMSAH (Integrated Mars Sample Acquisition and Handling) rotary percussive corer uses many of the same rocks as the MSL suite. An additional performance parameter is core integrity. The MSL development test drill and the IMSAH test drill use similar hardware to provide rotation and percussion. However, the MSL test drill uses external stabilizers, while the IMSAH test drill does not have external stabilization. In addition the IMSAH drill is a core drill, while the MSL drill uses a solid powdering bit. Results from the testing of these two related drilling systems is examined.

  18. Measurement of ability emotional intelligence: results for two new tests.

    Science.gov (United States)

    Austin, Elizabeth J

    2010-08-01

    Emotional intelligence (EI) has attracted considerable interest amongst both individual differences researchers and those in other areas of psychology who are interested in how EI relates to criteria such as well-being and career success. Both trait (self-report) and ability EI measures have been developed; the focus of this paper is on ability EI. The associations of two new ability EI tests with psychometric intelligence, emotion perception, and the Mayer-Salovey-Caruso EI test (MSCEIT) were examined. The new EI tests were the Situational Test of Emotion Management (STEM) and the Situational Test of Emotional Understanding (STEU). Only the STEU and the MSCEIT Understanding Emotions branch were significantly correlated with psychometric intelligence, suggesting that only understanding emotions can be regarded as a candidate new intelligence component. These understanding emotions tests were also positively correlated with emotion perception tests, and STEM and STEU scores were positively correlated with MSCEIT total score and most branch scores. Neither the STEM nor the STEU were significantly correlated with trait EI tests, confirming the distinctness of trait and ability EI. Taking the present results as a starting-point, approaches to the development of new ability EI tests and models of EI are suggested.

  19. Proposed Interventions to Decrease the Frequency of Missed Test Results

    Science.gov (United States)

    Wahls, Terry L.; Cram, Peter

    2009-01-01

    Numerous studies have identified that delays in diagnosis related to the mishandling of abnormal test results are an import contributor to diagnostic errors. Factors contributing to missed results included organizational factors, provider factors and patient-related factors. At the diagnosis error conference continuing medical education conference…

  20. EOL3 M0 X-ray Tomography Test Results

    CERN Document Server

    Avramidou, R; Bozhko, N; Borisov, A; Goriatchev, V; Goriatchev, S; Gushin, V; Fakhroutdinov, R; Kojine, A; Kononov, A; Larionov, A; Salomatin, Yu I; Schuh, S; Sedykh, Yu; Tchougouev, A

    2001-01-01

    Results of X-ray tomography test of EOL3 module 0 chamber is presented in the note. Peculiarities of the X-ray tomography of the chamber are discussed. Comparison of the tomography results with predictions of the production site measurements is made.

  1. Automated Testing Infrastructure and Result Comparison for Geodynamics Codes

    Science.gov (United States)

    Heien, E. M.; Kellogg, L. H.

    2013-12-01

    The geodynamics community uses a wide variety of codes on a wide variety of both software and hardware platforms to simulate geophysical phenomenon. These codes are generally variants of finite difference or finite element calculations involving Stokes flow or wave propagation. A significant problem is that codes of even low complexity will return different results depending on the platform due to slight differences in hardware, software, compiler, and libraries. Furthermore, changes to the codes during development may affect solutions in unexpected ways such that previously validated results are altered. The Computational Infrastructure for Geodynamics (CIG) is funded by the NSF to enhance the capabilities of the geodynamics community through software development. CIG has recently done extensive work in setting up an automated testing and result validation system based on the BaTLab system developed at the University of Wisconsin, Madison. This system uses 16 variants of Linux and Mac platforms on both 32 and 64-bit processors to test several CIG codes, and has also recently been extended to support testing on the XSEDE TACC (Texas Advanced Computing Center) Stampede cluster. In this work we overview the system design and demonstrate how automated testing and validation occurs and results are reported. We also examine several results from the system from different codes and discuss how changes in compilers and libraries affect the results. Finally we detail some result comparison tools for different types of output (scalar fields, velocity fields, seismogram data), and discuss within what margins different results can be considered equivalent.

  2. Electromagnetic results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Nishi, Masataka; Okuno, Kiyoshi; Takahashi, Yoshikazu; Tsuji, Hiroshi; Ando, Toshinari; Shimamoto, Susumu

    1984-01-01

    The domestic test of the Japanese LCT coil was carried out in 1982. During this test, the coil was charged up to the single coil's 100% state (10.22kA, 6.4T, 106MJ) four times and experienced no quenche. at the 100% charging state, coil stability was tested by using heaters installed in the conductor. A half turn length normal zone (about 5 m) generated by heaters was spontenously disappeared in 2 second. This normalized zone included the highest magnetic field position. The transport current which gives the stable limit is extraporated to be about 12.5kA at 8T by this test result. The dump test was carried out also from the 100% charging state. At that time, about 90% of the coil's stored energy was extracted by the dump resistor and the coil was not damaged. (author)

  3. Test results and operational characteristics of prototype SSCL half cell

    International Nuclear Information System (INIS)

    McInturff, A.D.; Burgett, W.; Carter, H.

    1994-01-01

    The SSCL Accelerator System's String Test (ASST) has had several cool down, subsequent operational test series, and warm up cycles. The first cycle of these was rather limited in scope as mandated by Congress. The subsequent tests have been performed to obtain more complete information about parameters of, or operating experience with, the ensemble of magnets and spools when operating serially as in accelerator operations. The tests and procedures performed to date have emphasized cryogenic, mechanical, and electrical operations. These have included running, as well as upset conditions, i.e., superconducting to normal transition of the string (quench). This paper represents a summary of the operational test results and characteristics seen to date. A limited discussion will be included as to their implications with respect to a successful accelerator operation

  4. Depressurisation studies. Phase 2: results of Tests 127 and 128

    International Nuclear Information System (INIS)

    Edwards, A.R.; Borgartz, B.O.; Goodman, R.M.E.; O'Brien, T.P.; Rawlingson, M.

    1978-06-01

    A basic experimental programme involving the sudden depressurisation of a simple pipe system containing water at 3.45 to 17.24MPa pressure and temperature in the range of 200 to 250 0 C has been concluded. Measurements were made of the transient density, pressure, and temperature variations in a two phase fluid in the system during discharge. Phase 1 tests investigated blowdown from straight pipes 4m long with constant internal diameters of 73 and 32 mm. Phase 2 tests incorporated a reservoir added to the 32mm pipe. In this, the second of three reports on Phase 2 tests, the test assembly, instrumentation and experimental procedure are briefly described. The conditions and results are reported for two of the tests in which the liquid in the long discharge pipe was initially subcooled by 10 0 C and 15 0 C while the reservoir was at saturation conditions with a steam dome present. (UK)

  5. Serological diagnosis of Toxoplasma gondii infection: Recommendations from the French National Reference Center for Toxoplasmosis.

    Science.gov (United States)

    Villard, O; Cimon, B; L'Ollivier, C; Fricker-Hidalgo, H; Godineau, N; Houze, S; Paris, L; Pelloux, H; Villena, I; Candolfi, E

    2016-01-01

    Toxoplasmosis manifests no clinical signs in 80% of cases in immunocompetent patient, causing immunization characterized by the persistence of cysts, particularly in brain, muscles, and retina. Assessing the serological status, based on testing for serum toxoplasma IgG and IgM antibodies, is essential in cases that are increasingly at risk for the more severe disease forms, such as congenital or ocular toxoplasmosis. This disease also exposes immunosuppressed patients to reactivation, which can lead to more widespread forms and increased mortality. By interpreting the serological results, we can estimate the risk of contamination or reactivation and define appropriate prophylactic and preventive measures, such as hygienic and dietetic, therapeutic, biological, and clinical follow-up, according to the clinical context. We hereby propose practical approaches based on serological data, resulting from a consensus of a group of experts from the French National Reference Center Network for Toxoplasmosis, according to both routine and specific clinical situations. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  7. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  8. Analysis of SCTF/CCTF counterpart test results

    International Nuclear Information System (INIS)

    Okubo, Tsutomu; Sobajima, Makoto; Iwamura, Takamichi; Ohnuki, Akira; Abe, Yutaka; Adachi, Hiromichi; Murao, Yoshio

    1990-06-01

    Slab Core Test Facility (SCTF) and Cylindrical Core Test Facility (CCTF) are large scale experimental facilities of Japan Atomic Energy Research Institute (JAERI) for the investigation of reflooding behavior during a postulated loss-of-coolant accident (LOCA) in PWRs. Although the flow area scaling ratios of both facilities to a 1,000 MWe class PWR are the same and 1/21.4, the SCTF has the same core width as the radius of the reference PWR while the CCTF has a 1/4.5 times shorter core radius. Therefore, a few SCTF/CCTF counterpart tests were conducted in order to investigate the difference in core reflooding behavior between in the SCTF and CCTF tests as well as the effect of core radial length on core two-dimensional thermo-hydrodynamic behavior. This report present the test results and an analysis on them. Major results obtained are: (1) Taking account of the differences in test conditions and facility design, core reflooding behavior is considered to be similar between the SCTF and the CCTF test. Main difference of the facility design is in the effective core flow area and this is considered to result in the difference in core water accumulation behavior. (2) The effect of core radial length on core two-dimensional thermo-hydrodynamic behavior has been observed to be significant and heat transfer enhancement or degradation in radial direction is more significant for the longer radius core. (3) In addition, where the core power varies significantly in the radial direction, significant heat transfer enhancement has been observed in the higher power bundle during the LPCI period. Also, in the peripheral region, heat transfer degradation has been observed more significantly in the outer bundle even they have the same bundle power. (4) Magnitude of these heat transfer enhancement or degradation was larger at the higher elevation than the midplane level in the SCTF test, whereas smaller in the CCTF test. (author)

  9. Improved PFB operations - 400-hour turbine test results

    Science.gov (United States)

    Rollbuhler, R. J.; Benford, S. M.; Zellars, G. R.

    1980-04-01

    The paper deals with a 400-hr small turbine test in the effluent of a pressurized fluidized bed (PFB) at an average temperature of 770 C, an average relative gas velocity of 300 m/sec, and average solid loadings of 200 ppm. Consideration is given to combustion parameters and operating procedure as well as to the turbine system and turbine test operating procedures. Emphasis is placed on erosion/corrosion results.

  10. Test Beam Results of a 3D Diamond Detector

    CERN Document Server

    Dunser, Marc

    2015-01-01

    3D pixel technology has been used successfully in the past with silicon detectors for tracking applications. Recently, a first prototype of the same 3D technology has been produced on a chemical vapour deposited single-crystal diamond sensor. This device has been subsequently tested in a beam test at CERN’s SPS accelerator in a beam of 120 GeV protons. Details on the production and results of testbeam data are presented.

  11. Creep in rock salt with temperature. Testing methods and results

    International Nuclear Information System (INIS)

    Charpentier, J.P.; Berest, P.

    1985-01-01

    The growing interest shown in the delayed behaviour of rocks at elevated temperature has led the Solid Mechanics Laboratory to develop specific equipment designed for creep tests. The design and dimensioning of these units offer the possibility of investigating a wide range of materials. The article describes the test facilities used (uni-axial and tri-axial creep units) and presents the experimental results obtained on samples of Bresse salt [fr

  12. Acoustic results of the Boeing model 360 whirl tower test

    Science.gov (United States)

    Watts, Michael E.; Jordan, David

    1990-09-01

    An evaluation is presented for whirl tower test results of the Model 360 helicopter's advanced, high-performance four-bladed composite rotor system intended to facilitate over-200-knot flight. During these performance measurements, acoustic data were acquired by seven microphones. A comparison of whirl-tower tests with theory indicate that theoretical prediction accuracies vary with both microphone position and the inclusion of ground reflection. Prediction errors varied from 0 to 40 percent of the measured signal-to-peak amplitude.

  13. Results of initial nuclear tests on LWBR (LWBR Development Program)

    International Nuclear Information System (INIS)

    Sarber, W.K.

    1979-06-01

    This report presents and discusses the results of physics tests performed at beginning of life on the Light Water Breeder Reactor (LWBR). These tests have confirmed that movable seed assembly critical positions and reactivity worths, temperature coefficients, xenon transient characteristics, core symmetry, and core shutdown are within the range of values used in the design of the LWBR and its reactor protection analysis. Measured core physics parameters were found to be in good agreement with the calculated values

  14. Wellbore inertial navigation system (WINS) software development and test results

    Energy Technology Data Exchange (ETDEWEB)

    Wardlaw, R. Jr.

    1982-09-01

    The structure and operation of the real-time software developed for the Wellbore Inertial Navigation System (WINS) application are described. The procedure and results of a field test held in a 7000-ft well in the Nevada Test Site are discussed. Calibration and instrumentation error compensation are outlined, as are design improvement areas requiring further test and development. Notes on Kalman filtering and complete program listings of the real-time software are included in the Appendices. Reference is made to a companion document which describes the downhole instrumentation package.

  15. Construction details and test results from RHIC sextupoles

    International Nuclear Information System (INIS)

    Lindner, M.; Anerella, M.; Ganetis, G.

    1993-01-01

    Four 8 cm aperture sextupoles have been built at BNL to verify the magnetic performance of this magnet in the RHIC installation. Two significantly different mechanical configurations have been designed, and two magnets of each design have been built, and successfully tested, and have exceeded the required minimum quench current by a substantial margin. This report describes the assembly details of the second configuration, which is the final production configuration. In addition the first industry built production sextupole has been delivered and tested. This report presents the results of quench tests on all 5 magnets and field measurements on the first production sextupole

  16. Advanced Stirling Convertor Durability Testing: Plans and Interim Results

    Science.gov (United States)

    Meer, David W.; Oriti, Salvatore M.

    2012-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, GRC has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

  17. Results of patch testing in 10 patients with peristomal dermatitis.

    Science.gov (United States)

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  19. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallmann, F.W.; Guthrie, G.; McElroy, W.N.

    1985-01-01

    The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within +- 20 0 C of the measured values for Δ NDT. None of the different methods is clearly superior; (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment. (orig.)

  20. Thermal Analysis of Low Layer Density Multilayer Insulation Test Results

    Science.gov (United States)

    Johnson, Wesley L.

    2011-01-01

    Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.

  1. Clinical Trial Results Summary for Laypersons: A User Testing Study.

    Science.gov (United States)

    Raynor, D K; Myers, L; Blackwell, K; Kress, B; Dubost, A; Joos, A

    2018-01-01

    To apply "user testing" to maximize readability and acceptability of a Clinical Trial Results Laypersons Summary-a new European requirement. "User testing" (using questionnaire and semistructured interview) assessed whether people could find and understand key points. Findings were used to improve content and design, prior to retesting. Participants had a range of levels of health literacy and there was a higher education group. Participants accessed the summary on screen. In round 1 we tested 12 points of information. In round 2 a revised summary addressing round 1 findings was tested, leading to a third final version. In round 1, 2 of 12 points of information did not reach the target and interviews raised further format and content issues (some distracting technical explanations and inability to find or understand the 2 main study purposes). These findings informed revisions for the version tested in round 2, with 2 different points not reaching the target (inclusion criteria relating to duration of seasonal allergies and how researchers found out about participants' symptoms). Identified problems in both rounds were addressed and reflected in the final version. Despite improvements, participants did not consistently understand that summaries were intended for the public, or to only interpret results of single trials in the context of additional trials. All readers, including those with higher education, found the clear and straightforward language acceptable. Applying "user testing" resulted in a largely health-literate summary suitable for people across a range of backgrounds.

  2. Spent fuel drying system test results (first dry-run)

    International Nuclear Information System (INIS)

    Klinger, G.S.; Oliver, B.M.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

    1998-07-01

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks in the basin have been detected and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site. Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the first dry-run test, which was conducted without a fuel element. The empty test apparatus was subjected to a combination of low- and high-temperature vacuum drying treatments that were intended to mimic, wherever possible, the fuel treatment strategies of the IPS. The data from this dry-run test can serve as a baseline for the first two fuel element tests, 1990 (Run 1) and 3128W (Run 2). The purpose of this dry-run was to establish the background levels of hydrogen in the system, and the hydrogen generation and release characteristics attributable to the test system without a fuel element present. This test also serves to establish the background levels of water in the system and the water release characteristics. The system used for the drying test series was the Whole Element Furnace Testing System, described in Section 2.0, which is located in the Postirradiation Testing Laboratory (PTL, 327 Building). The test conditions and methodology are given in section 3.0, and the experimental

  3. Serological and molecular evidence of hepadnavirus infection in swine

    Directory of Open Access Journals (Sweden)

    Yasmine R Vieira

    2015-02-01

    Full Text Available [b]Introduction and objective[/b]. Recently, investigations in a swine herd identified evidence of the existence of a novel member of the Hepadnavirus family endemic in swine. The aim of this study was to investigate the serological and molecular markers of Hepadnavirus circulation in Brazilian domestic swine and wild boar herds, and to evaluate the identity with HBV and other Hepadnaviruses reported previously. [b]Materials and methods[/b]. For the study, 376 swine were screened for hepatitis B virus serological markers. Analyses were performed in serum samples using commercial enzyme-linked immunosorbent assay (ELISA kits (DiaSorin® for anti-HBc, HBsAg and anti-HBs. Reactive and undetermined swine serum samples were selected to perform DNA viral extraction (QIAamp DNA Mini Kit, Qiagen®, partial genome amplification and genome sequencing. [b]Results[/b]. From 376 swine samples analysed, 28 (7.45% were reactive to anti-HBc, 3 (0.80% to HBsAg and 6 (1.6% to anti-HBs. Besides, more 17 (4.52% swine samples analyzed were classified in the grey zone of the EIA test to anti-HBc and 2 (0.53% to HBsAg. From 49 samples molecularly analyzed after serological trial, 4 samples showed a positive result for the qualitative PCR for Hepadnavirus. Phylogenetic reconstruction using partial genome sequencing (360 bp of 3 samples showed similarity with HBV with 90.8–96.3% of identity. [b]Conclusions.[/b] Serological and molecular data showed evidence of the circulation of a virus similar to hepatitis B virus in swine.

  4. Molecular blood typing augments serologic testing and allows for enhanced matching of red blood cells for transfusion in patients with sickle cell disease.

    Science.gov (United States)

    Wilkinson, Katie; Harris, Samantha; Gaur, Prashant; Haile, Askale; Armour, Rosalind; Teramura, Gayle; Delaney, Meghan

    2012-02-01

    Sickle cell disease (SCD) patients have dissimilar red blood cell (RBC) phenotypes compared to the primarily Caucasian blood donor base due, in part, to underlying complex Rh and silenced Duffy expression. Gene array-based technology offers high-throughput antigen typing of blood donors and can identify patients with altered genotypes. The purpose of the study was to ascertain if RBC components drawn from predominantly Caucasian donors could provide highly antigen-matched products for molecularly typed SCD patients. SCD patients were genotyped by a molecular array (HEA Beadchip, BioArray Solutions). The extended antigen phenotype (C, c, E, e, K, k, Jk(a) , Jk(b) , Fy(a) , Fy(b) , S, s) was used to query the inventory using different matching algorithms; the resulting number of products was recorded. A mean of 96.2 RBC products was available for each patient at basic-level, 34 at mid-level, and 16.3 at high-level stringency. The number of negative antigens correlated negatively with the number of available products. The Duffy silencing mutation in the promoter region (67T>C) (GATA) was found in 96.5% of patients. Allowing Fy(b+) products for patients with GATA increased the number of available products by up to 180%, although it does not ensure prevention of Duffy antibodies in all patients. This feasibility study provides evidence that centers with primarily Caucasian donors may be able to provide highly antigen-matched products. Knowledge of the GATA status expands the inventory of antigen-matched products. Further work is needed to determine the most clinically appropriate match level for SCD patients. © 2012 American Association of Blood Banks.

  5. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  6. The CANopen Controller IP Core: Implementation, Synthesis and Test Results

    Science.gov (United States)

    Caramia, Maurizio; Bolognino, Luca; Montagna, Mario; Tosi, Pietro; Errico, Walter; Bigongiari, Franco; Furano, Gianluca

    2011-08-01

    This paper will describe the implementation and test results of the CANopen Controller IP Core (CCIPC) implemented by Thales Alenia Space and SITAEL Aerospace with the support of ESA in the frame of the EXOMARS Project. The CCIPC is a configurable VHDL implementation of the CANOPEN protocol [1]; it is foreseen to be used as CAN bus slave controller within the EXOMARS Entry Descending and Landing Demonstrato Module (EDM) and Rover Module. The CCIPC features, configuration capability, synthesis and test results will be described and the evidence of the state of maturity of this innovative IP core will be demonstrated.

  7. Large coil task and results of testing US coils

    International Nuclear Information System (INIS)

    Haubenreich, P.N.

    1986-01-01

    The United States, EURATOM, Japan, and Switzerland have collaborated since 1978 in development of superconducting toroidal field coils for fusion reactor applications. The United States provided a test facility nd three coils; the other participants, one coil each. All coils have the same interface dimensions and performance requirements (stable at 8 T), but internal design was decided by each team. Two US coil teams chose bath-cooled NbTi, 10-kA conductors. One developed a Nb 3 Sn conductor, cooled by internal flow, rated at 18 kA. All US coils have diagnostic instrumentation and imbedded heaters that enable stability tests and simulated nuclear heating experiments. In single-coil tests, each coil operated at full current in self-field (6.4 T). In six-coil tests that began in July 1986, one US coil and the Japanese coil hve been successfully operated at full current at 8 T. The other coils have operated as background coils while awaiting their turn as test coil. Coil tests have been informative and results gratifying. The facility has capably supported coil testing and its operation has provided information that will be useful in designing future fusion systems. Coil capabilities beyond nominal design points will be determined

  8. Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-01

    The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

  9. [Evaluation of the Recombinant Protein Tp0965 of Treponema Pallidum as Perspective Antigen for the Improved Serological Diagnosis of Syphilis].

    Science.gov (United States)

    Runina, A V; Starovoitova, A S; Deryabin, D G; Kubanov, A A

    2016-01-01

    BACKGRAUND. Treponemal tests based on the detection of antibodies against the Treponema pallidum antigens are the most specific methods for serological diagnosis of syphilis. Due to the inability to cultivate this bacterium in vitro, the most promising sources of antigens for diagnostics are recombinant proteins of T. pallidum. Evaluation of the analytical value of certain T. pallidum proteins is the approach to improve sensitivity, specificity, and reproducibility of syphilis serological tests, including possibilities of differential diagnosis of various forms of the disease. The aim of the research was to evaluate the analytical values (sensitivity and specificity) of recombinant protein Tp0965 of T. pallidum as a candidate antigen for serological diagnosis of syphilis. tp0965 gene was cloned into the expression vector pET28a and the construct was used for the transformation of E. coli BL-21 (DE3) cells and further expression and purification of the recombinant protein. The collected protein was used as T. pallidum antigen for serum analysis (ELISA) of groups of patients with various forms of syphilis (n=84) and the group of healthy donors (n = 25). High frequency of positive ELISA results was shown with serum of patients with syphilis, compared to the group of healthy donors. The sensitivity of serological reactions using recombinant protein Tp0965 was 98.8%, specificity--87.5%. The highest sensitivity (100%) was detected in the groups of patients with primary, secondary and early latent syphilis while in the group of patients with late latent syphilis it decreased to 95.2%. We concluded that due to its specificity T. pallidum recombinant protein Tp0965 can be used as a novel perspective antigen for development of syphilis serological diagnostic assays (for primary and early latent forms).

  10. Test results of the SMES model coil. Pulse performance

    International Nuclear Information System (INIS)

    Hamajima, Takataro; Shimada, Mamoru; Ono, Michitaka

    1998-01-01

    A model coil for superconducting magnetic energy storage (SMES model coil) has been developed to establish the component technologies needed for a small-scale 100 kWh SMES device. The SMES model coil was fabricated, and then performance tests were carried out in 1996. The coil was successfully charged up to around 30 kA and down to zero at the same ramp rate of magnetic field experienced in a 100 kWh SMES device. AC loss in the coil was measured by an enthalpy method as parameters of ramp rate and flat top current. The results were evaluated by an analysis and compared with short-sample test results. The measured hysteresis loss is in good agreement with that estimated from the short-sample results. It was found that the coupling loss of the coil consists of two major coupling time constants. One is a short time constant of about 200 ms, which is in agreement with the test results of a short real conductor. The other is a long time constant of about 30 s, which could not be expected from the short sample test results. (author)

  11. LWR aerosol containment experiments (LACE) program and initial test results

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.; Bloom, G.R.; McCormack, J.D.; Rahn, F.J.

    1985-01-01

    The LWR aerosol containment experiments (LACE) program is described. The LACE program is being performed at the Hanford Engineer Development Laboratory (operated by Westinghouse Hanford Company) and the initial tests are sponsored by EPRI. The objectives of the LACE program are: to demonstrate, at large-scale, inherent radioactive aerosol retention behavior for postulated high consequence LWR accident situations; and to provide a data base to be used for aerosol behavior . Test results from the first phase of the LACE program are presented and discussed. Three large-scale scoping tests, simulating a containment bypass accident sequence, demonstrated the extent of agglomeration and deposition of aerosols occurring in the pipe pathway and vented auxiliary building under realistic accident conditions. Parameters varied during the scoping tests were aerosol type and steam condensation

  12. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  13. Results of assembly test of HTTR reactor internals

    International Nuclear Information System (INIS)

    Maruyama, S.; Saikusa, A.; Shiozawa, S.; Tsuji, N.; Miki, T.

    1996-01-01

    The assembly test of the HTTR actual reactor internals had been carried out at the works, prior to their installation in the actual reactor pressure vessel(RPV) at the construction site. The assembly test consists of several items such as examining fabricating precision of each component and alignment of piled-up structures, measuring circumferential coolant velocity profile in the passage between the simulated RPV and the reactor internals as well as under the support plates, measuring by-pass flow rate through gaps between the reactor internals, and measuring the binding force of the core restraint mechanism. Results of the test showed good performance of the HTTR reactor internals. Installation of the reactor internals in the actual RPV was started at the construction site of HTTR in April, 1995. In the installation process, main items of the assembly test at the works were repeated to investigate the reproducibility of installation. (author). 5 refs, 11 figs

  14. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  15. Wind tunnel test IA300 analysis and results, volume 1

    Science.gov (United States)

    Kelley, P. B.; Beaufait, W. B.; Kitchens, L. L.; Pace, J. P.

    1987-01-01

    The analysis and interpretation of wind tunnel pressure data from the Space Shuttle wind tunnel test IA300 are presented. The primary objective of the test was to determine the effects of the Space Shuttle Main Engine (SSME) and the Solid Rocket Booster (SRB) plumes on the integrated vehicle forebody pressure distributions, the elevon hinge moments, and wing loads. The results of this test will be combined with flight test results to form a new data base to be employed in the IVBC-3 airloads analysis. A secondary objective was to obtain solid plume data for correlation with the results of gaseous plume tests. Data from the power level portion was used in conjunction with flight base pressures to evaluate nominal power levels to be used during the investigation of changes in model attitude, eleveon deflection, and nozzle gimbal angle. The plume induced aerodynamic loads were developed for the Space Shuttle bases and forebody areas. A computer code was developed to integrate the pressure data. Using simplified geometrical models of the Space Shuttle elements and components, the pressure data were integrated to develop plume induced force and moments coefficients that can be combined with a power-off data base to develop a power-on data base.

  16. Retrospective investigation of serological finding in diagnosis of parasite agents caused mass in liver

    Directory of Open Access Journals (Sweden)

    Safinaz Demirkaya

    2014-06-01

    Full Text Available Objective: Many of parasite agent cause diseases damaging the liver. The parasite infections settled the liver give rise to focal mass named as reactive hyperplasia or granulomatous reactions in this organ. Some of parasites caused focal mass in liver are cystic echinococ, Fasciola hepatica and Entamoeba histolytica. The diagnoses of these parasites which are localized to liver have been carried out with serological methods (Indirect hemagglutination (IHA, Indirect Fluorescent Antibody Technic (IFAT and ELISA (Enzyme Linked Immunosorbent Assay and radiological imaging. In this study, we was aimed to investigating of prevalence with serological methods of parasite diseases like cystic echinococcosis, fascioliasis and amebic liver abscess in patients determined preliminary diagnosis mass with radiological imaging Methods: For this study, One hundred patient’s sera were included to investigation. It were investigated E.histolytica antibody with IHA method, anti-echinococcus IgG antibody with IFAT method and anti-fasciolia hepatica IgG antibody with ELISA method in sera of patient’s determined mass preliminary diagnosis with radiological imaging. Results: It were encountered these parasite in 27% of patients who determined mass preliminary diagnosis. It was determined in 1% E.histolytica, 13% Cystic echinococcus and 13% Fasciola hepatica seropositive of patients. Conclusion: The patients detected mass preliminary in liver should be evaluated for these parasites. We believe that will not be enough only radiological imaging in identification of these parasitic infections and should definitely need to be supported with a serological test.

  17. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  18. Test-beam results of a SOI pixel detector prototype

    CERN Document Server

    Bugiel, Roma; Dannheim, Dominik; Fiergolski, Adrian; Hynds, Daniel; Idzik, Marek; Kapusta, P; Kucewicz, Wojciech; Munker, Ruth Magdalena; Nurnberg, Andreas Matthias

    2018-01-01

    This paper presents the test-beam results of a monolithic pixel-detector prototype fabricated in 200 nm Silicon-On-Insulator (SOI) CMOS technology. The SOI detector was tested at the CERN SPS H6 beam line. The detector is fabricated on a 500 μm thick high-resistivity float- zone n-type (FZ-n) wafer. The pixel size is 30 μm × 30 μm and its readout uses a source- follower configuration. The test-beam data are analysed in order to compute the spatial resolution and detector efficiency. The analysis chain includes pedestal and noise calculation, cluster reconstruction, as well as alignment and η-correction for non-linear charge sharing. The results show a spatial resolution of about 4.3 μm.

  19. Guidelines to Interpret Results of Mechanical Blade Test

    International Nuclear Information System (INIS)

    Arias Vega, F.; Sanz Martin, J. C.

    1999-01-01

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blade as an allowable product, fit for use and working with a completely security during all the wind turbines lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the authors technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  20. Guidelines to Interpret Results of Mechanical Blade Test

    Energy Technology Data Exchange (ETDEWEB)

    Arias Vega, F.; Sanz Martin, J. C. [Ciemat, Madrid (Spain)

    2000-07-01

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blades as an allowable product, fit for use and working with a completely security during all the windturbine's lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the author's technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  1. Results for the Brine Evaporation Bag (BEB) Brine Processing Test

    Science.gov (United States)

    Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin

    2015-01-01

    The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.

  2. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  3. Pattern Of Skin Prick Allergy Test Results In Enugu | Mgbor ...

    African Journals Online (AJOL)

    In this study we report on pattern of allergy prick skin test results found among atopic patients attending the department of otorhinolargngology of the University of Nigeria Teaching Hospital Enugu and Hansa Clinics, Enugu and propose ways of minimizing the exposure of the population to allergens. Material and method

  4. Test Beam Results Obtained with the Q4 Prototype

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Benitez, M.; Alberdi, J.; Cerrada, M.; Colino, N.; Daniel, M.; Fouz, M. c.; Marin, J.; Mocholi, J.; Oller, J. C.; Puerta, J.; Romero, L.; Salicio, J. M.

    2000-07-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built at CIEMAT using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented here. (Author)

  5. Recent results on the RIA test in IGR reactor

    International Nuclear Information System (INIS)

    Asmolov, V.; Yegorova, L.

    1997-01-01

    At the 23d WRSM meeting the data base characterizing results of VVER high burnup fuel rods tests under reactivity-initiated accident (RIA) conditions was presented. Comparison of PWR and VVER failure thresholds was given also. Additional analysis of the obtained results was being carried out during 1996. The results of analysis show that the two different failure mechanisms were observed for PWR and VVER fuel rods. Some factors which can be as the possible reasons of these differences are presented. First of them is the state of preirradiated cladding. Published test data for PWR high burnup fuel rods demonstrated that the PWR high burnup fuel rods failed at the RIA test are characterized by very high level of oxidation and hydriding for the claddings. Corresponding researches were performed at Institute of Atomic Reactors (RLAR, Dimitrovgrad, Russia) for large set of VVER high burnup fuel rods. Results of these investigations show that preirradiated commercial Zr-1%Nb claddings practically keep their initial levels of oxidation and H 2 concentration. Consequently the VVER preirradiated cladding must keep the high level of mechanical properties. The second reason leading to differences between failure mechanisms for two types of high burnup fuel rods can be the test conditions. Now such kind of analysis have been performed by two methods

  6. Interpretation of Chemical Pathology Test Results in Paediatrics ...

    African Journals Online (AJOL)

    At any time we interprete paediatric chemical pathology test results we must take into consideration a number of factors, which are related with and restricted to paediatric patients. Such factors include the paediatric patient's age that may change from prematurity to above 18 years, and the paediatric patient's body weight ...

  7. VEGETABLE OILS AS SUBSTITUTION FOR DIESEL OIL Test results ...

    African Journals Online (AJOL)

    Test results obtained on a Diesel Engine with direct injection. W. Scheer, Professor ... High kinematic viscosities, high flash points and high ... nozzle and in the combustion chamber. This is ... speed, fuel consumption and exhaust tempera· tures. ... it enters the fuel system of the engine. An one ..... Internal publi- cation of ...

  8. SIMS prototype System 3 test results: engineering analysis

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating are presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  9. Multi-bundle shashlik calorimeter prototypes beam-test results

    International Nuclear Information System (INIS)

    Badier, J.; Bloch, P.; Bityukov, S.; Bordalo, P.; Busson, P.; Charlot, C.; Dobrzynski, L.; Golutvin, I.; Guschin, E.; Issakov, V.; Ivanchenko, I.; Klimenko, V.; Marin, V.; Moissenz, P.; Obraztsov, V.; Ostankov, A.; Popov, V.; Puljak, I.; Ramos, S.; Seez, C.; Sergueev, S.; Soushkov, V.; Tanaka, R.; Varela, J.; Virdee, T.S.; Zaitchenko, A.; Zamiatin, N.

    1995-01-01

    The first beam-test results for two- and three-bundle shashlik tower prototypes are described. We found that the spatial resolution, the uniformity of energy response, the calorimeter reliability and hermeticity and also two showers separation are improved in multi-bundle design approach. ((orig.))

  10. SIMS prototype system 3 test results: Engineering analysis

    Science.gov (United States)

    1978-01-01

    The results obtained during testing of a closed hydronic drain down solar system designed for space and hot water heating is presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 3 for field installation.

  11. Results of the Intelligence Test for Visually Impaired Children (ITVIC).

    Science.gov (United States)

    Dekker, R.; And Others

    1991-01-01

    Statistical analyses of scores on subtests of the Intelligence Test for Visually Impaired Children were done for two groups of children, either with or without usable vision. Results suggest that the battery has differential factorial and predictive validity. (Author/DB)

  12. Test beam results obtained with the Q4 prototype

    International Nuclear Information System (INIS)

    Aguilar-Benitez, M.; Alberdi, J.; Cerrada, M.; Colino, N.; Daniel, M.; Fouz, M.C.; Marin, J.; Mocholi, J.; Oller, J. C.; Puerta, J.; Romero, L.; Salicio, J. M.; Willmott, C.

    2000-10-01

    A prototype of the CMS Barrel Muon Detector incorporating all the features of the final chambers was built at CIEMAT using the mass production assembly procedures and tools. The performance of this prototype was studied in a muon test beam at CERN and the results obtained are presented here. (Author)

  13. Prenatal diagnosis of congenital toxoplasmosis: comparative value of fetal blood and amniotic fluid using serological techniques and cultures.

    Science.gov (United States)

    Fricker-Hidalgo, H; Pelloux, H; Muet, F; Racinet, C; Bost, M; Goullier-Fleuret, A; Ambroise-Thomas, P

    1997-09-01

    The prenatal diagnosis of congenital toxoplasmosis is mainly based on biological tests performed on fetal blood and amniotic fluid. We studied the performance of neonatal diagnosis procedures and the results of fetal blood and amniotic fluid analysis. Of 127 women who contracted toxoplasmosis and underwent prenatal diagnosis, the postnatal serological follow-up was long enough to definitively diagnose congenital toxoplasmosis in 19 cases and to exclude it in 27 cases. Prenatal diagnosis allowed the detection of 94.7 per cent (18/19) of the infected fetuses. The sensitivities of tests in amniotic fluid and fetal blood were equivalent, 88.2 per cent (15/17) and 87.5 per cent (14/16), respectively. In fetal blood, biological techniques were positive in 12/16 cases and in 2/16 cases, serological tests were the only positive sign. The specificities of tests in amniotic fluid and fetal blood were respectively 100 per cent (23/23) and 86.3 per cent (19/22) (three false-positive serological results). These results, added to the lower morbidity of amniocentesis compared with cordocentesis, might lead to cordocentesis being abandoned in the prenatal diagnosis of congenital toxoplasmosis.

  14. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  15. Space Launch System Base Heating Test: Experimental Operations & Results

    Science.gov (United States)

    Dufrene, Aaron; Mehta, Manish; MacLean, Matthew; Seaford, Mark; Holden, Michael

    2016-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

  16. Graphite electrode arc melter demonstration Phase 2 test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O'Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau's Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of open-quotes as-receivedclose quotes heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process

  17. Graphite electrode arc melter demonstration Phase 2 test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O`Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process.

  18. Comparison of transient PCRV model test results with analysis

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Belytschko, T.B.

    1979-01-01

    Comparisons are made of transient data derived from simple models of a reactor containment vessel with analytical solutions. This effort is a part of the ongoing process of development and testing of the DYNAPCON computer code. The test results used in these comparisons were obtained from scaled models of the British sodium cooled fast breeder program. The test structure is a scaled model of a cylindrically shaped reactor containment vessel made of concrete. This concrete vessel is prestressed axially by holddown bolts spanning the top and bottom slabs along the cylindrical walls, and is also prestressed circumferentially by a number of cables wrapped around the vessel. For test purposes this containment vessel is partially filled with water, which comes in direct contact with the vessel walls. The explosive charge is immersed in the pool of water and is centrally suspended from the top of the vessel. The tests are very similar to the series of tests made for the COVA experimental program, but the vessel here is the prestressed concrete container. (orig.)

  19. 688,112 statistical results: Content mining psychology articles for statistical test results

    OpenAIRE

    Hartgerink, C.H.J.

    2016-01-01

    In this data deposit, I describe a dataset that is the result of content mining 167,318 published articles for statistical test results reported according to the standards prescribed by the American Psychological Association (APA). Articles published by the APA, Springer, Sage, and Taylor & Francis were included (mining from Wiley and Elsevier was actively blocked). As a result of this content mining, 688,112 results from 50,845 articles were extracted. In order to provide a comprehensive set...

  20. Performance of seven serological assays for diagnosing tularemia

    Science.gov (United States)

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  1. Results of MACE tests M0 and M1

    International Nuclear Information System (INIS)

    Spencer, B.W.; Farmer, M.T.; Armstrong, D.R.; Kilsdonk, D.J.; Aeschlimann, R.W.; Fischer, M.

    1992-01-01

    This document discusses the Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship. The program addresses the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in the reactor containment. Large-scale experiments are being conducted in parallel with related modeling efforts, involving the addition of water to an MCI already underway. The experiments utilize UO 2 /ZrO 2 /Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test MO was a successful scoping test, but the first full size test, Ml, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m 2 was measured in MO which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m 2 and less. Both tests MO and Ml revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test Ml provided evidence of occasional ''burst mode'' ablation events and one additional important benefit of overlying water -- aerosol capture

  2. Paternity tests in Mexico: Results obtained in 3005 cases.

    Science.gov (United States)

    García-Aceves, M E; Romero Rentería, O; Díaz-Navarro, X X; Rangel-Villalobos, H

    2018-04-01

    National and international reports regarding the paternity testing activity scarcely include information from Mexico and other Latin American countries. Therefore, we report different results from the analysis of 3005 paternity cases analyzed during a period of five years in a Mexican paternity testing laboratory. Motherless tests were the most frequent (77.27%), followed by trio cases (20.70%); the remaining 2.04% included different cases of kinship reconstruction. The paternity exclusion rate was 29.58%, higher but into the range reported by the American Association of Blood Banks (average 24.12%). We detected 65 mutations, most of them involving one-step (93.8% and the remaining were two-step mutations (6.2%) thus, we were able to estimate the paternal mutation rate for 17 different STR loci: 0.0018 (95% CI 0.0005-0.0047). Five triallelic patterns and 12 suspected null alleles were detected during this period; however, re-amplification of these samples with a different Human Identification (HID) kit confirmed the homozygous genotypes, which suggests that most of these exclusions actually are one-step mutations. HID kits with ≥20 STRs detected more exclusions, diminishing the rate of inconclusive results with isolated exclusions (Powerplex 21 kit (20 STRs) and Powerplex Fusion kit (22 STRs) offered similar PI (p = 0.379) and average number of exclusions (PE) (p = 0.339) when a daughter was involved in motherless tests. In brief, besides to report forensic parameters from paternity tests in Mexico, results describe improvements to solve motherless paternity tests using HID kits with ≥20 STRs instead of one including 15 STRs. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  3. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  4. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  5. The TRANSRAPID propulsion system - development and test results

    Energy Technology Data Exchange (ETDEWEB)

    Henning, U [Siemens AG, Erlangen (Germany); Kamp, P G [Siemens AG, Erlangen (Germany); Hochleitner, J [Siemens AG, Erlangen (Germany)

    1996-12-31

    The structure of the propulsion system for the Transrapid comprises a number of components which are located along the guideway. These drive components are temporarily switched together to form the drive control zones necessary to permit maglev operation over the guideway. The paper describes the development of the stationary propulsion converter with GTO thyristors. The drive components are tested under realistic operating conditions. The test results confirm the performance capability as well as verify the suitability of the concept for use in revenue service. (HW)

  6. Thermosyphon Flooding in Reduced Gravity Environments Test Results

    Science.gov (United States)

    Gibson, Marc A.; Jaworske, Donald A.; Sanzi, Jim; Ljubanovic, Damir

    2013-01-01

    The condenser flooding phenomenon associated with gravity aided two-phase thermosyphons was studied using parabolic flights to obtain the desired reduced gravity environment (RGE). The experiment was designed and built to test a total of twelve titanium water thermosyphons in multiple gravity environments with the goal of developing a model that would accurately explain the correlation between gravitational forces and the maximum axial heat transfer limit associated with condenser flooding. Results from laboratory testing and parabolic flights are included in this report as part I of a two part series. The data analysis and correlations are included in a follow on paper.

  7. PISA TESTS IN LATIN AMERICA: RESULTS IN CONTEXT

    Directory of Open Access Journals (Sweden)

    Guillermina Tiramonti

    2014-05-01

    Full Text Available The educational reforms implemented in Latin America in the ‘90s introduced changes in the modes of regulation of educational systems based on the adoption of mechanisms for assessing student achievement. Since 2000, eight Latin-American countries (Argentina, Chile, Uruguay, Colombia, Brazil, Costa Rica, Mexico and Peru are involved in the PISA tests. The article presents a brief review of the social and educational situation of the Region, relevant for the interpretation and comparative analysis of the results of these tests that is presented below.

  8. Test Results of the ALICE-HMPID Detector Commissioning

    CERN Document Server

    Volpe, G

    2008-01-01

    The ALICE High Momentum Particle Identification Detector (HMPID) consists of seven identical proximity focusing RICH counters. It covers in total 11 m2, exploiting large area CsI photocathodes for Cherenkov light imaging. The detector is installed in the ALICE solenoid, ready for the data acquisition. By means of the Detector Control System, the Front-end (FEE) and the Readout (R/O) electronics, the MWPC high voltages, the cooling and the gas system have been tested. The HMPID module gas pressure, temperature, current and voltage trends have been monitored and archived in the ORACLE database. In this paper a comprehensive review on the test results is presented.

  9. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  10. Autoimmune liver serology: current diagnostic and clinical challenges.

    Science.gov (United States)

    Bogdanos, Dimitrios-P; Invernizzi, Pietro; Mackay, Ian-R; Vergani, Diego

    2008-06-07

    Liver-related autoantibodies are crucial for the correct diagnosis and classification of autoimmune liver diseases (AiLD), namely autoimmune hepatitis types 1 and 2 (AIH-1 and 2), primary biliary cirrhosis (PBC), and the sclerosing cholangitis variants in adults and children. AIH-1 is specified by anti-nuclear antibody (ANA) and smooth muscle antibody (SMA). AIH-2 is specified by antibody to liver kidney microsomal antigen type-1 (anti-LKM1) and anti-liver cytosol type 1 (anti-LC1). SMA, ANA and anti-LKM antibodies can be present in de-novo AIH following liver transplantation. PBC is specified by antimitochondrial antibodies (AMA) reacting with enzymes of the 2-oxo-acid dehydrogenase complexes (chiefly pyruvate dehydrogenase complex E2 subunit) and disease-specific ANA mainly reacting with nuclear pore gp210 and nuclear body sp100. Sclerosing cholangitis presents as at least two variants, first the classical primary sclerosing cholangitis (PSC) mostly affecting adult men wherein the only (and non-specific) reactivity is an atypical perinuclear antineutrophil cytoplasmic antibody (p-ANCA), also termed perinuclear anti-neutrophil nuclear antibodies (p-ANNA) and second the childhood disease called autoimmune sclerosing cholangitis (ASC) with serological features resembling those of type 1 AIH. Liver diagnostic serology is a fast-expanding area of investigation as new purified and recombinant autoantigens, and automated technologies such as ELISAs and bead assays, become available to complement (or even compete with) traditional immunofluorescence procedures. We survey for the first time global trends in quality assurance impacting as it does on (1) manufacturers/purveyors of kits and reagents, (2) diagnostic service laboratories that fulfill clinicians' requirements, and (3) the end-user, the physician providing patient care, who must properly interpret test results in the overall clinical context.

  11. 688,112 statistical results : Content mining psychology articles for statistical test results

    NARCIS (Netherlands)

    Hartgerink, C.H.J.

    2016-01-01

    In this data deposit, I describe a dataset that is the result of content mining 167,318 published articles for statistical test results reported according to the standards prescribed by the American Psychological Association (APA). Articles published by the APA, Springer, Sage, and Taylor & Francis

  12. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    Science.gov (United States)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  13. Results of the quality assurance testing program for radiopharmaceuticals 1995

    International Nuclear Information System (INIS)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( 99m Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [ 201 Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs

  14. Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Brian Keith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boero, Riccardo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rivera, Michael Kelly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whether model changes are needed in order to improve its behavior qualitatively and quantitatively.

  15. Results of the quality assurance testing program for radiopharmaceuticals 1995

    Energy Technology Data Exchange (ETDEWEB)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( {sup 99m}Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [{sup 201}Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs.

  16. TEST RESULTS FOR LHC INSERTION REGION DEPOLE MAGNETS

    International Nuclear Information System (INIS)

    MURATORE, J.; JAIN, A.; ANERELLA, M.; COSSOLINO, J.

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They are required to produce fields up to 4.14 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, whose construction was very different from the RHIC dipoles, except for the coil design. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality

  17. Using Large Scale Test Results for Pedagogical Purposes

    DEFF Research Database (Denmark)

    Dolin, Jens

    2012-01-01

    The use and influence of large scale tests (LST), both national and international, has increased dramatically within the last decade. This process has revealed a tension between the legitimate need for information about the performance of the educational system and teachers to inform policy......, and the teachers’ and students’ use of this information for pedagogical purposes in the classroom. We know well how the policy makers interpret and use the outcomes of such tests, but we know less about how teachers make use of LSTs to inform their pedagogical practice. An important question is whether...... there is a contradiction between the political system’s use of LST and teachers’ (possible) pedagogical use of LST. And if yes: What is a contradiction based on? This presentation will give some results from a systematic review on how tests have influenced the pedagogical practice. The research revealed many of the fatal...

  18. SP-100 Fuel Pin Performance: Results from Irradiation Testing

    Science.gov (United States)

    Makenas, Bruce J.; Paxton, Dean M.; Vaidyanathan, Swaminathan; Marietta, Martin; Hoth, Carl W.

    1994-07-01

    A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pins are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.

  19. Containment liner plate anchors and steel embedments test results

    International Nuclear Information System (INIS)

    Chang-Lo, P.L.; Johnson, T.E.; Pfeifer, B.W.

    1977-01-01

    This paper summarizes test data on shear load and deformation capabilities for liner plate line anchors and structural steel embedments in reinforced and prestressed concrete nuclear containments. Reinforced and prestressed nuclear containments designed and constructed in the United States are lined with a minimum of 0.64 cm steel plate. The liner plates are anchored by the use of either studs or structural members (line anchors) which usually run in the vertical direction. This paper will only address line anchors. Static load versus displacement test data is necessary to assure that the design is adequate for the maximum loads. The test program for the liner anchors had the following major objectives: determine load versus displacement data for a variety of anchors considering structural tees and small beams with different weld configurations, from the preceding tests, determine which anchors would lead to an economical and extremely safe design and test these anchors for cyclic loads resulting from thermal fluctuations. Various concrete embeds in the containment and other structures are subjected to loads such as pipe rupture which results in shear. Since many of the loads are transient by nature, it is necessary to know the load-displacement relationship so that the energy absorption can be determined. The test program for the embeds had the following objectives: determine load-displacement relationship for various size anchors from 6.5 cm 2 to 26 cm 2 with maximum capacities of approximately 650 kN; determine the effect of various anchor width-to-thickness ratios for the same shear area

  20. Results of gap conductance tests in the power burst facility

    International Nuclear Information System (INIS)

    Garner, R.W.; Sparks, D.T.

    1977-01-01

    Light water reactor (LWR) fuel rod behavior studies are being conducted by the Thermal Fuels Behavior Program of EG and G Idaho, Inc. These studies are being performed under contract to the Energy Research and Development Adminstration at the Idaho National Engineering Laboratory (INEL), as part of the Nuclear Regulatory Commission's Water Reactor Safety Research Fuel Behavior Program. Experimental data for verification of analytical models developed to predict light water nuclear fuel rod behavior under normal and postulated accident conditions are being obtained from a variety of in-reactor and out-of-reactor experiments. This paper summarizes the results of tests performed in the Power Burst Facility (PBF) to obtain data from which the thermal response, gap conductance, and stored energy of LWR fuel rods can be determined. Primary objectives of the PBF gap conductance test program are (a) to obtain data on a variety of pressurized water reactor (PWR) and boiling water reactor (BWR) fuel rod designs, under a wide range of operating conditions, from which gap conductance values can be determined and (b) to evaluate experimentally the power oscillation method for measuring the gap conductance and thermal response of a fresh or burned LWR fuel rod. Tests have been performed with both irradiated and unirradiated PWR-type fuel and with fresh BWR-type fuel rods. Some PWR rod test results are described, and the thermal response data from BWR rod tests are discussed in greater detail. Comparisons are made of gap conductance values determined by the tests with analytically calculated values using the Fuel Rod Analysis Program-Transient (FRAP-T) computer code. These comparisons provide insight into both the experimental measurements methods and the validity of the gap conductance models

  1. An Outbreak of Human Coronavirus OC43 Infection and Serological Cross-Reactivity with SARS Coronavirus

    Directory of Open Access Journals (Sweden)

    David M Patrick

    2006-01-01

    Full Text Available BACKGROUND: In summer 2003, a respiratory outbreak was investigated in British Columbia, during which nucleic acid tests and serology unexpectedly indicated reactivity for severe acute respiratory syndrome coronavirus (SARS-CoV.

  2. Large-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Gauglitz, Phillip A.; Burns, Carolyn A.; Fountain, Matthew S.; Shimskey, Rick W.; Billing, Justin M.; Bontha, Jagannadha R.; Kurath, Dean E.; Jenks, Jeromy WJ; MacFarlan, Paul J.; Mahoney, Lenna A.

    2013-08-01

    One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used

  3. Spent fuel drying system test results (second dry-run)

    International Nuclear Information System (INIS)

    Klinger, G.S.; Oliver, B.M.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

    1998-07-01

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks have been detected in the basins and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site (WHC 1995). Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the second dry-run test, which was conducted without a fuel element. With the concurrence of project management, the test protocol for this run, and subsequent drying test runs, was modified. These modifications were made to allow for improved data correlation with drying procedures proposed under the IPS. Details of these modifications are discussed in Section 3.0

  4. Experimental Results of Integrated Refrigeration and Storage System Testing

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Jumper, K.

    2009-01-01

    Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

  5. Results of patch testing with lavender oil in Japan.

    Science.gov (United States)

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  6. Overview of results from 2D airfoil testing at Risoe

    Energy Technology Data Exchange (ETDEWEB)

    Fuglsang, P. [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1997-12-31

    This paper gives an overview of the results from two dimensional airfoil testing at Risoe. A two dimensional testing method was recently developed where a test rig is inserted into an open jet flow in a wind tunnel of the close return loop type with an open test section. Pressure measurements provide the lift and drag forces. Both stationary flow and dynamic inflow from pitch motion are possible. The wind tunnel static pressure and total dynamic pressures were calibrated and wind tunnel boundary corrections were found. So far, the testing method was verified by comparison of NACA 63-215 airfoil measurements to numerical predictions and to measurements. Furthermore, the Risoe-1, FFA-W3-241, FFA-W3-301 and NACA 63-430 airfoils were measured. Different types of leading edge roughness and vortex generators were investigated. For all airfoils, good agreements with predictions were obtained on both pressure distribution and on lift coefficient. The drag coefficients were slightly higher than predicted. (eg) 10 refs.

  7. VLT deformable secondary mirror: integration and electromechanical tests results

    Science.gov (United States)

    Biasi, R.; Andrighettoni, M.; Angerer, G.; Mair, C.; Pescoller, D.; Lazzarini, P.; Anaclerio, E.; Mantegazza, M.; Gallieni, D.; Vernet, E.; Arsenault, R.; Madec, P.-Y.; Duhoux, P.; Riccardi, A.; Xompero, M.; Briguglio, R.; Manetti, M.; Morandini, M.

    2012-07-01

    The VLT Deformable secondary is planned to be installed on the VLT UT#4 as part of the telescope conversion into the Adaptive Optics test Facility (AOF). The adaptive unit is based on the well proven contactless, voice coil motor technology that has been already successfully implemented in the MMT, LBT and Magellan adaptive secondaries, and is considered a promising technical choice for the forthcoming ELT-generation adaptive correctors, like the E-ELT M4 and the GMT ASM. The VLT adaptive unit has been recently assembled after the completion of the manufacturing and modular test phases. In this paper, we present the most relevant aspects of the system integration and report the preliminary results of the electromechanical tests performed on the unit. This test campaign is a typical major step foreseen in all similar systems built so far: thanks to the metrology embedded in the system, that allows generating time-dependent stimuli and recording in real time the position of the controlled mirror on all actuators, typical dynamic response quality parameters like modal settling time, overshoot and following error can be acquired without employing optical measurements. In this way the system dynamic and some aspect of its thermal and long term stability can be fully characterized before starting the optical tests and calibrations.

  8. Serological analysis and therapy in patients with early syphilis

    International Nuclear Information System (INIS)

    Wu Zhifen

    2000-01-01

    Sixty one patients with early syphilis were treated with benzathine penicillin under guide of serological analysis, the results showed that benzathine penicilline was able to cure indurated chancre and skin rashes in a month, flat condyloma in one and a half month, and PRP were all negative in 18 month

  9. Comparison of radioimmunology and serology methods for LH determination

    International Nuclear Information System (INIS)

    Szymanski, W.; Jakowicki, J.

    1976-01-01

    A comparison is presented of LH determinations by immunoassay and radioimmunoassay using the 125 I-labelled HCG double antibody system. The results obtained by both methods are well comparable and in normal and elevated LH levels the serological determinations may be used for estimating concentration levels found by RIA. (L.O.)

  10. Test Results for the Automated Rendezvous and Capture System

    Science.gov (United States)

    Cruzen, Craig; Dabney, Richard; Lomas, James

    1999-01-01

    The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.

  11. Honeywell Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  12. Postirradiation examination results for the Irradiation Effects Scoping Test 2

    International Nuclear Information System (INIS)

    Mehner, A.S.

    1977-01-01

    The postirradiation examination results are reported for two rods from the second scoping test (IE-ST-2) of the Nuclear Regulatory Commission Irradiation Effects Program. The rods were irradiated in the in-pile test loop of the Power Burst Facility at the Idaho National Engineering Laboratory. Rod IE-005 was fabricated from fresh fuel and cladding previously irradiated in the Saxton Reactor. Rod IE-006, fabricated from fresh fuel and unirradiated cladding, was equipped with six developmental cladding surface thermocouples. The rods were preconditioned, power ramped, and then subjected to film boiling operation. The performance of the rods and the developmental thermocouples are evaluated from the post irradiation examination results. The effects of prior irradiation damage in cladding are discussed in relation to fuel rod behavior during a power ramp and subsequent film boiling operation

  13. Results of a first beam test of hadron blind trackers

    Energy Technology Data Exchange (ETDEWEB)

    Chen, M. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Luckey, D. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Smolin, M. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Sumorok, K. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Zhang, X. (Laboratory for Nuclear Science, MIT, Cambridge, MA (United States)); Bolozdynya, A. (ITEP, Moscow (Russian Federation)); Belogurov, S. (ITEP, Moscow (Russian Federation)); Churakov, D. (ITEP, Moscow (Russian Federation)); Koutchenkov, A. (ITEP, Moscow (Russian Federation)); Kovalenko, A. (ITEP, Moscow (Russian Federation)); Kuzichev, V. (ITEP, Moscow (Russian Federation)); Lebedenko, V. (ITEP, Moscow (Russian Federation)); Sheinkman, V. (ITEP, Moscow (Russian Federation)); Smirnov, G. (ITEP, Moscow (Russian Federation)); Safronov, G. (ITEP, Moscow (Russian Federation)); Vinogradov, V. (ITEP, Moscow (Russian Federation)); Giomataris, Y. (IPN,

    1994-07-15

    We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF[sub 4] with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight pads. Beam tests confirm the large Cherenkov light bandwidth in the EUV region that can be obtained with such gas mixtures. It results in a large quality factor of about 500 cm[sup -1] which allows HBD operation with a much shorter radiator thickness than conventional Cherenkov counters. Full electron efficiency was obtained, while pions were rejected up to momenta of 9 GeV/c. HBD is unique in measuring electron trajectories near the vertex, vetoing Dalitz pairs, and providing trigger on electrons among heavy hadron background. We discuss the use of such detectors for lepton identification and detection in high energy physics experiments and especially in heavy ion colliders. ((orig.))

  14. Results of a first beam test of hadron blind trackers

    International Nuclear Information System (INIS)

    Chen, M.; Luckey, D.; Smolin, M.; Sumorok, K.; Zhang, X.; Bolozdynya, A.; Belogurov, S.; Churakov, D.; Koutchenkov, A.; Kovalenko, A.; Kuzichev, V.; Lebedenko, V.; Sheinkman, V.; Smirnov, G.; Safronov, G.; Vinogradov, V.; Giomataris, Y.; Joseph, C.; Werlen, M.; Charpak, G.; Blumenfeld, B.; Gougas, A.K.; Steele, D.; Akopyan, M.

    1994-01-01

    We describe the experimental results of a new type of electron tracker, called Hadron Blind Detector or HBD. An HBD prototype was tested with gas mixtures of CF 4 with He or Ne and a parallel plate avalanche chamber having a CsI photocathode of eight pads. Beam tests confirm the large Cherenkov light bandwidth in the EUV region that can be obtained with such gas mixtures. It results in a large quality factor of about 500 cm -1 which allows HBD operation with a much shorter radiator thickness than conventional Cherenkov counters. Full electron efficiency was obtained, while pions were rejected up to momenta of 9 GeV/c. HBD is unique in measuring electron trajectories near the vertex, vetoing Dalitz pairs, and providing trigger on electrons among heavy hadron background. We discuss the use of such detectors for lepton identification and detection in high energy physics experiments and especially in heavy ion colliders. ((orig.))

  15. Summary of Test Results for Daya Bay Rock Samples

    International Nuclear Information System (INIS)

    Onishi, Celia Tiemi; Dobson, Patrick; Nakagawa, Seiji

    2004-01-01

    A series of analytical tests was conducted on a suite of granitic rock samples from the Daya Bay region of southeast China. The objective of these analyses was to determine key rock properties that would affect the suitability of this location for the siting of a neutrino oscillation experiment. This report contains the results of chemical analyses, rock property measurements, and a calculation of the mean atomic weight

  16. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the {open_quotes}sources{close_quotes} and {open_quotes}targets{close_quotes} requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  17. Seismic II over I Drop Test Program results and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the [open quotes]sources[close quotes] and [open quotes]targets[close quotes] requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources.

  18. Seismic II over I Drop Test Program results and interpretation

    International Nuclear Information System (INIS)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the open-quotes sourcesclose quotes and open-quotes targetsclose quotes requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources

  19. Differential distribution of age and HBV serological markers in liver cirrhosis and non-cirrhotic patients with primary liver cancer

    Directory of Open Access Journals (Sweden)

    XU Xiuhua

    2013-03-01

    Full Text Available ObjectiveTo compare the age distributions and presence of hepatitis B virus (HBV serological markers between primary hepatic cancer (PHC patients with and without liver cirrhosis. MethodsA total of 547 PHC cases were analyzed retrospectively. After dividing into two groups according to liver cirrhosis status, the between-group differences in age and HBV serological markers, such as hepatitis B e antigen (HBeAg status, were statistically compared using the Chi-squared test. ResultsThe number of cirrhotic and non-cirrhotic PHC patients was 265 and 282, respectively. HBV infection was present in 221 cirrhotic PHC patients and 256 non-cirrhotic PHC patients (834% vs. 90.8%. There was a substantial bias in the proportion of males to females in the cirrhotic PHC patients (7.83∶1. The number of PHC patients <60 years old was similar between the cirrhotic and non-cirrhotic groups, but the non-cirrhotic group had significantly more patients >60 years old (P<0.005. In cirrhotic PHC patients, the HBV infection rate was highest in the <40 years old age group (96.7% and the HBeAg serological conversion rate was highest in the 40-60 years old age group (89.5%. In non-cirrhotic PHC patients, the 40-60 years old age group showed the highest HBV infection rate (90.3% but the lowest HBeAg serological conversion rate (80.0%. ConclusionPHC with liver cirrhosis mainly occurred in males, with the HBV infection rate being higher in individuals <60 years old. Non-cirrhotic PHC patients were more often >60 years old. Many of the HBV-infected PHC patients with cirrhosis had high HBeAg serological conversion rate.

  20. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  1. 21 CFR 640.5 - Testing the blood.

    Science.gov (United States)

    2010-04-01

    ... be negative to a serological test for syphilis. (b) Determination of blood group. Each container of... sample. The label shall indicate the extent of typing and the results of all tests performed. If the test... test is negative, the results shall be confirmed by further testing which shall include tests for the...

  2. The first operation of the Delphos plant: Test results

    International Nuclear Information System (INIS)

    Sarno, A.; Noviello, G.; Cordisco, S.; Di Paola, L.; Guerra, M.

    1991-09-01

    The data collected during the O and M of the Delphos plant and the testing results are presented and discussed. Together with the maintenance influence on the operation and production of the plant, the various downtime causes are pointed out. An extensive activity has been carried out to investigate the actual behaviour of the photovoltaic generator and the power conditioning unit. The analysis of the experimental results allows to focus on the different causes of loss and suggest some actions to be taken in order to improve the plant efficiency and increase the energy production. (author)

  3. Reproducibility problems of in-service ultrasonic testing results

    International Nuclear Information System (INIS)

    Honcu, E.

    1974-01-01

    The reproducibility of the results of ultrasonic testing is the basic precondition for its successful application in in-service inspection of changes in the quality of components of nuclear power installations. The results of periodic ultrasonic inspections are not satisfactory from the point of view of reproducibility. Regardless, the ultrasonic pulse-type method is suitable for evaluating the quality of most components of nuclear installations and often the sole method which may be recommended for inspection with regard to its technical and economic aspects. (J.B.)

  4. Test beam results from a scintillating fibers-lead calorimeter

    International Nuclear Information System (INIS)

    Caria, M.

    1991-01-01

    The SpaCal collaboration has built prototypes of lead-scintillating fibers calorimter. The aim is to check predicted performances. Here are briefly mentioned results obtained from prototypes tests in beam of e, π, μ at CERN. Layers 2m long of extruded lead, were equipped with 1mm fibers in an hexagonal geometry. The ratio of scintillator to lead was 1/4. Results are presented on the most appealing features of such a calorimeter: energy resolution, homogeneity, containment and compensation. It is shown, that excellent energy resolution togehter with compensation has been achieved. (orig.)

  5. Postirradiation examination results for the Irradiation Effects Test 2

    International Nuclear Information System (INIS)

    Ploger, S.A.; Kerwin, D.K.; Croucher, D.W.

    1978-01-01

    This report presents the postirradiation examination results of Test IE-2 in the Irradiation Effects Test Series conducted under the Thermal Fuels Behavior Program. The objectives of this test were to evaluate the influence of previous cladding irradiation and fuel-cladding diametral gap on fuel rod behavior during a power ramp and during film boiling operation. Test IE-2, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed two 0.97-m-long pressurized water reactor type fuel rods fabricated from previously irradiated zircaloy-4 cladding and two similar rods fabricated from unirradiated cladding. The four rods were subjected to a preconditioning period, followed by a power ramp to an average peak rod power of 68 kW/m and steady state operation for one hour at an individual rod coolant mass flux of 4880 kg/s . m 2 . After a flow reduction to 2550 kg/s . m 2 , film boiling occurred on three rods. An additional flow reduction to 2245 kg/s . m 2 produced film boiling on the remaining fuel rod. Maximum time in film boiling was 90 s. None of the four fuel rods failed during the test. Damage caused by film boiling, as characterized by oxidation, oxide spalling, and collapse at fuel pellet interfaces, was found on all four rods. Film boiling regions on these rods showed evidence of fuel melting, fuel centerline void formation, and internal cladding oxidation resulting from fuel-cladding reaction. Effects of fuel-cladding diametral gap and cladding irradiation are summarized. Measured temperatures and metallographically estimated temperatures are compared at several axial fuel rod locations

  6. Test results of sodium-water reaction testing in near prototypical LMR steam generator

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hui, M.; Neely, H.H.

    1990-01-01

    An extensive test program has been performed in the United States to investigate the effects of large sodium-water reaction events in LMFBR steam generators. Tests were conducted in the Large Leak Test Rig (LLTR) located at the Energy Technology Engineering Center (ETEC). The program was divided into two phases, Series I and Series II, for the purpose of satisfying near-term and long-term needs. Series II was further subdivided into large and intermediate leak tests. This paper will emphasize the Series II intermediate leak tests and resulting conclusions for steam generator design and operation. 11 figs, 2 tabs

  7. Challenges in interpretation of thyroid hormone test results

    Directory of Open Access Journals (Sweden)

    Lalić Tijana

    2016-01-01

    Full Text Available Introduction. In interpreting thyroid hormones results it is preferable to think of interference and changes in concentration of their carrier proteins. Outline of Cases. We present two patients with discrepancy between the results of thyroid function tests and clinical status. The first case presents a 62-year-old patient with a nodular goiter and Hashimoto thyroiditis. Thyroid function test showed low thyroid-stimulating hormone (TSH and normal to low fT4. By determining thyroid status (ТSH, T4, fT4, T3, fT3 in two laboratories, basal and after dilution, as well as thyroxine-binding globulin (TBG, it was concluded that the thyroid hormone levels were normal. The results were influenced by heterophile antibodies leading to a false lower TSH level and suspected secondary hypothyroidism. The second case, a 40-year-old patient, was examined and followed because of the variable size thyroid nodule and initially borderline elevated TSH, after which thyroid status showed low level of total thyroid hormones and normal TSH. Based on additional analysis it was concluded that low T4 and T3 were a result of low TBG. It is a hereditary genetic disorder with no clinical significance. Conclusion. Erroneous diagnosis of thyroid disorders and potentially harmful treatment could be avoided by proving the interference or TBG deficiency whenever there is a discrepancy between the thyroid function results and the clinical picture.

  8. Automation and results of Adjacent Band Emission testing

    Science.gov (United States)

    2015-03-01

    Problem Statement : Multiple groups conduct tests in various ways - Outcomes vary based on test setup and assumptions - No standard has been established to conduct such tests - Spectrum is scarce and the need for compliance testing will only increase...

  9. Postirradiation examination results for the Irradiation Effects Test IE-5

    International Nuclear Information System (INIS)

    Cook, T.F.; Ploger, S.A.; Hobbins, R.R.

    1978-03-01

    The results are presented of the postirradiation examination of four pressurized water reactor type fuel rods which were tested in-pile under a fast power ramp and film boiling operation during Irradiation Effects (IE) Test 5. The major objectives of this test were to evaluate the effects of simulated fission products on fuel rod behavior during a fast power ramp, to determine the effects of high initial internal pressure on a fuel rod during film boiling, and to assess fuel rod property changes that occur during film boiling in a fuel rod with previously irradiated cladding. The overall condition of the rods and changes that occurred in fuel and cladding as a result of the power ramp and film boiling operation, as determined from the postirradiation examination, are reported and analyzed. Effects of the simulated fission products on fuel rod behavior during a power ramp are discussed. The effect of high internal pressure on rod behavior during film boiling is evaluated. Cladding temperatures are estimated at various axial and circumferential locations. Cladding embrittlement by oxidation is also assessed

  10. Benchmark Calculations on Halden IFA-650 LOCA Test Results

    International Nuclear Information System (INIS)

    Ek, Mirkka; Kekkonen, Laura; Kelppe, Seppo; Stengaard, J.O.; Josek, Radomir; Wiesenack, Wolfgang; Aounallah, Yacine; Wallin, Hannu; Grandjean, Claude; Herb, Joachim; Lerchl, Georg; Trambauer, Klaus; Sonnenburg, Heinz-Guenther; Nakajima, Tetsuo; Spykman, Gerold; Struzik, Christine

    2010-01-01

    through several blow-downs and heat-ups and reached peak clad temperatures of more than 1000 C. In the second run, where the rod was sufficiently pre-pressurised, ballooning and burst was obtained. The first benchmark consisted of three rounds of code calculations related to IFA-650.3: 1. Pre-test calculations: Participants were provided with information regarding the setup of the Halden LOCA test facility, data from the commissioning runs, and information about the test pin and power conditions to be applied in the execution of the test. 2. Post-test calculations I: In addition to the information from the first round, participants were provided with the in-pile results from the test. 3. Post-test calculations II, unified thermal-hydraulic boundary conditions: Calculations were repeated using a cladding temperature distribution calculated with ATHLET-CD at GRS. Since the test, when executed, did not produce the expected ballooning and fuel relocation, it was decided to continue with a second benchmark using tests 650.4 and 650.5, this time as post-test calculations. The fourth test of the series, IFA-650.4 conducted in April 2006, caused particular attention in the international nuclear community. The fuel used in the experiment had a high burnup, 92 MWd/kgU, and a low pre-test hydrogen content of about 50 ppm. The cladding burst at about 790 deg. C caused a marked temperature increase at the lower end of the segment and a decrease at the upper end, indicating that fuel relocation had occurred. Subsequent gamma scanning showed that approximately 19 cm (40%) of the fuel stack were missing from the upper part of the rod. PIE at the IFE-Kjeller hot cells corroborated this evidence of substantial fuel relocation. This report presents the results of the codes which participated in the various benchmarks. The two main parts, on benchmark I and II, each start with a brief description of the most important experimental data. Then, the code calculation results follow

  11. Use of serological diagnostic techniques in the control and eradication of caprine arthritis encephalitis: an update

    Directory of Open Access Journals (Sweden)

    Jamili Maria Suhet Mussi

    2015-12-01

    Full Text Available Caprine arthritis encephalitis (CAE is a chronic disease caused by a small ruminant lentivirus (SRLV, which causes significant losses in goat breeding. The actual state of animal infection with SRLV is difficult to determine due to a complex pathogenesis of the virus, including factors such as delayed or intermittent seroconversion in serological tests. Several serological techniques are available for disease diagnosis, such as screening or confirmation tests, which are different in sensitivity and specificity. Regarding the choice of the test to be applied, availability of commercial immunoreagents, team training, antigen used, and cost of techniques must be considered. This review presents the serological methods available for use in different stages of CAE control and eradication programs, and management measures to be adopted in conjunction with serological diagnosis of the disease.

  12. Structural damping results from vibration tests of straight piping sections

    International Nuclear Information System (INIS)

    Ware, A.G.; Thinnes, G.L.

    1984-01-01

    EG and G Idaho is assisting the USNRC and the Pressure Vessel Research Committee in supporting a final position on revised damping values for structural analyses of nuclear piping systems. As part of this program, a series of vibrational tests on 76-mm and 203-mm (3-in. amd 8-in.) Schedule 40 carbon steel piping was conducted to determine the changes in structural damping due to various parametric effects. The 10-m (33-ft) straight sections of piping were rigidly supported at the ends. Spring, rod, and constant force hangers, as well as a sway brace and snubbers were included as intermediate supports. Excitation was provided by low-force level hammer inpacts, a hydraulic shaker, and a 445-kN (50-ton) overhead crane. Data was recorded using acceleration, strain, and displacement time histories. This paper presents results from the testing showing the effect of stress level and type of supports on structural damping in piping

  13. LEDA RF distribution system design and component test results

    International Nuclear Information System (INIS)

    Roybal, W.T.; Rees, D.E.; Borchert, H.L.; McCarthy, M.; Toole, L.

    1998-01-01

    The 350 MHz and 700 MHz RF distribution systems for the Low Energy Demonstration Accelerator (LEDA) have been designed and are currently being installed at Los Alamos National Laboratory. Since 350 MHz is a familiar frequency used at other accelerator facilities, most of the major high-power components were available. The 700 MHz, 1.0 MW, CW RF delivery system designed for LEDA is a new development. Therefore, high-power circulators, waterloads, phase shifters, switches, and harmonic filters had to be designed and built for this applications. The final Accelerator Production of Tritium (APT) RF distribution systems design will be based on much of the same technology as the LEDA systems and will have many of the RF components tested for LEDA incorporated into the design. Low power and high-power tests performed on various components of these LEDA systems and their results are presented here

  14. Experimental results of some cluster tests in NSRR

    International Nuclear Information System (INIS)

    Kobayashi, Shinsho; Ohnishi, Nobuaki; Yoshimura, Tomio; Lussie, W.G.

    1978-01-01

    The NSRR programme is in progress in JAERI using a pulsed reactor to evaluate the behavior of reactor fuels under reactivity accident conditions. This report describes briefly the experimental results and preliminary analysis of two cluster tests. In the cluster configuration of five fuel rods, the power distribution in outer fuel rods are not symmetric due to neutron absorption in central fuel rod. The cladding temperature on the exterior boundaries of the cluster is higher than that in interior. Good agreement was obtained between the calculated and measured cladding temperature histories. In the 3.8$ excess reactivity test, cluster averaged energy deposition of 237 cal/g.UO 2 , cladding melting and deformation were limited to the portions of the fuel rods that were on the exterior boundaries of the cluster. (auth.)

  15. Preliminary Results of Testing of Flow Effects on Evaporator Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Hu, M.Z.

    2002-02-15

    This investigation has focused on the effects of fluid flow on solids deposition from solutions that simulate the feed to the 2H evaporator at the Savannah River Site. Literature studies indicate that the fluid flow (or shear) affects particle-particle and particle-surface interactions and thus the phenomena of particle aggregation in solution and particle deposition (i.e., scale formation) onto solid surfaces. Experimental tests were conducted with two configurations: (1) using a rheometer to provide controlled shear conditions and (2) using controlled flow of reactive solution through samples of stainless steel tubing. All tests were conducted at 80 C and at high silicon and aluminum concentrations, 0.133 M each, in solutions containing 4 M sodium hydroxide and 1 A4 each of sodium nitrate and sodium nitrite. Two findings from these experiments are important for consideration in developing approaches for reducing or eliminating evaporator scaling problems: (1) The rheometer tests suggested that for the conditions studied, maximum solids deposition occurs at a moderate shear rate, approximately 12 s{sup -1}. That value is expected to be on the order of shear rates that will occur in various parts of the evaporator system; for instance, a 6 gal/min single-phase liquid flow through the 2-in. lift or gravity drain lines would result in a shear rate of approximately 16 s{sup -1}. These results imply that engineering approaches aimed at reducing deposits through increased mixing would need to generate shear near all surfaces significantly greater than 12 s{sup -1}. However, further testing is needed to set a target value for shear that is applicable to evaporator operation. This is because the measured trend is not statistically significant at the 95% confidence interval due to variability in the results. In addition, testing at higher temperatures and lower concentrations of aluminum and silicon would more accurately represent conditions in the evaporator. Without

  16. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  17. Results of Large-Scale Spacecraft Flammability Tests

    Science.gov (United States)

    Ferkul, Paul; Olson, Sandra; Urban, David L.; Ruff, Gary A.; Easton, John; T'ien, James S.; Liao, Ta-Ting T.; Fernandez-Pello, A. Carlos; Torero, Jose L.; Eigenbrand, Christian; hide

    2017-01-01

    For the first time, a large-scale fire was intentionally set inside a spacecraft while in orbit. Testing in low gravity aboard spacecraft had been limited to samples of modest size: for thin fuels the longest samples burned were around 15 cm in length and thick fuel samples have been even smaller. This is despite the fact that fire is a catastrophic hazard for spaceflight and the spread and growth of a fire, combined with its interactions with the vehicle cannot be expected to scale linearly. While every type of occupied structure on earth has been the subject of full scale fire testing, this had never been attempted in space owing to the complexity, cost, risk and absence of a safe location. Thus, there is a gap in knowledge of fire behavior in spacecraft. The recent utilization of large, unmanned, resupply craft has provided the needed capability: a habitable but unoccupied spacecraft in low earth orbit. One such vehicle was used to study the flame spread over a 94 x 40.6 cm thin charring solid (fiberglasscotton fabric). The sample was an order of magnitude larger than anything studied to date in microgravity and was of sufficient scale that it consumed 1.5 of the available oxygen. The experiment which is called Saffire consisted of two tests, forward or concurrent flame spread (with the direction of flow) and opposed flame spread (against the direction of flow). The average forced air speed was 20 cms. For the concurrent flame spread test, the flame size remained constrained after the ignition transient, which is not the case in 1-g. These results were qualitatively different from those on earth where an upward-spreading flame on a sample of this size accelerates and grows. In addition, a curious effect of the chamber size is noted. Compared to previous microgravity work in smaller tunnels, the flame in the larger tunnel spread more slowly, even for a wider sample. This is attributed to the effect of flow acceleration in the smaller tunnels as a result of hot

  18. Automotive RF immunity test set-up analysis : why test results can't compare

    NARCIS (Netherlands)

    Coenen, Mart; Pues, H.; Bousquet, T.

    2011-01-01

    Though the automotive RF emission and RF immunity requirements are highly justifiable, the application of those requirements in an non-intended manner leads to false conclusions and unnecessary redesigns for the electronics involved. When the test results become too dependent upon the test set-up

  19. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  20. Hanford coring bit temperature monitor development testing results report

    International Nuclear Information System (INIS)

    Rey, D.

    1995-05-01

    Instrumentation which directly monitors the temperature of a coring bit used to retrieve core samples of high level nuclear waste stored in tanks at Hanford was developed at Sandia National Laboratories. Monitoring the temperature of the coring bit is desired to enhance the safety of the coring operations. A unique application of mature technologies was used to accomplish the measurement. This report documents the results of development testing performed at Sandia to assure the instrumentation will withstand the severe environments present in the waste tanks