WorldWideScience

Sample records for serial serum samples

  1. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review.

    Science.gov (United States)

    Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W

    2017-01-01

    The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n  = 122 papers were included. The proteins S100B ( n  = 66) and NSE ( n  = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n  = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n  = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n  = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be

  2. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-07-01

    Full Text Available BackgroundThe proteins S100B, neuron-specific enolase (NSE, glial fibrillary acidic protein (GFAP, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1, and neurofilament light (NF-L have been serially sampled in serum of patients suffering from traumatic brain injury (TBI in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term “effective half-life” (t1/2 in order to describe the “fall” rate in serum.Materials and methodsThrough searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations.ResultsFollowing screening (10,389 papers, n = 122 papers were included. The proteins S100B (n = 66 and NSE (n = 27 were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1–2 h though possibly of non-cerebral origin. In contrast, the t1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP (n = 18 appears to have t1/2 of about 24–48 h in severe TBI. The protein UCH-L1 (n = 9 presents a t1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L (n = 2 only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use.ConclusionSerial sampling of brain-specific proteins in serum reveals

  3. Protein Turnover Measurements in Human Serum by Serial Immunoaffinity LC-MS/MS.

    Science.gov (United States)

    Farrokhi, Vahid; Chen, Xiaoying; Neubert, Hendrik

    2018-02-01

    The half-life of target proteins is frequently an important parameter in mechanistic pharmacokinetic and pharmacodynamic (PK/PD) modeling of biotherapeutics. Clinical studies for accurate measurement of physiologically relevant protein turnover can reduce the uncertainty in PK/PD model-based predictions, for example, of the therapeutic dose and dosing regimen in first-in-human clinical trials. We used a targeted mass spectrometry work flow based on serial immunoaffinity enrichment ofmultiple human serum proteins from a [5,5,5- 2 H 3 ]-L-leucine tracer pulse-chase study in healthy volunteers. To confirm the reproducibility of turnover measurements from serial immunoaffinity enrichment, multiple aliquots from the same sample set were subjected to protein turnover analysis in varying order. Tracer incorporation was measured by multiple-reaction-monitoring mass spectrometry and target turnover was calculated using a four-compartment pharmacokinetic model. Five proteins of clinical or therapeutic relevance including soluble tumor necrosis factor receptor superfamily member 12A, tissue factor pathway inhibitor, soluble interleukin 1 receptor like 1, soluble mucosal addressin cell adhesion molecule 1, and muscle-specific creatine kinase were sequentially subjected to turnover analysis from the same human serum sample. Calculated half-lives ranged from 5-15 h; however, no tracer incorporation was observed for mucosal addressin cell adhesion molecule 1. The utility of clinical pulse-chase studies to investigate protein turnover can be extended by serial immunoaffinity enrichment of target proteins. Turnover analysis from serum and subsequently from remaining supernatants provided analytical sensitivity and reproducibility for multiple human target proteins in the same sample set, irrespective of the order of analysis. © 2017 American Association for Clinical Chemistry.

  4. Reconstructing genealogies of serial samples under the assumption of a molecular clock using serial-sample UPGMA.

    Science.gov (United States)

    Drummond, A; Rodrigo, A G

    2000-12-01

    Reconstruction of evolutionary relationships from noncontemporaneous molecular samples provides a new challenge for phylogenetic reconstruction methods. With recent biotechnological advances there has been an increase in molecular sequencing throughput, and the potential to obtain serial samples of sequences from populations, including rapidly evolving pathogens, is fast being realized. A new method called the serial-sample unweighted pair grouping method with arithmetic means (sUPGMA) is presented that reconstructs a genealogy or phylogeny of sequences sampled serially in time using a matrix of pairwise distances. The resulting tree depicts the terminal lineages of each sample ending at a different level consistent with the sample's temporal order. Since sUPGMA is a variant of UPGMA, it will perform best when sequences have evolved at a constant rate (i.e., according to a molecular clock). On simulated data, this new method performs better than standard cluster analysis under a variety of longitudinal sampling strategies. Serial-sample UPGMA is particularly useful for analysis of longitudinal samples of viruses and bacteria, as well as ancient DNA samples, with the minimal requirement that samples of sequences be ordered in time.

  5. Serial measurements of serum human placental lactogen (hPL) and serial ultrasound examinations in the evaluation of fetal growth

    DEFF Research Database (Denmark)

    Sørensen, Steen; von Tabouillot, D; Schioler, V

    2000-01-01

    Serial serum hPL measurements and serial ultrasound fetometry were compared in the evaluation of fetal growth by relating these two parameters to size at birth and to clinical factors known to influence size at birth. The data were from a prospective study of 1000 consecutive pregnant women...... considered to be at risk for fetal growth retardation with retrospective analysis. Serum hPL was measured by radioimmunoassay and fetal weight estimated by ultrasound every 3 weeks during the last trimester. hPL values were expressed as multiples of the median (MoM) and linear regression analysis of the h......PL MoM values was carried out for each pregnancy to find the slope of the line (hPL-slope); at least 3 serum hPL values were required. The estimated fetal weight and weight-for-age at birth was expressed in Z-scores. The individual intrauterine growth velocity was calculated by regression analysis...

  6. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  7. A prospective study to investigate the role of serial serum mesothelin in monitoring mesothelioma.

    Science.gov (United States)

    de Fonseka, Duneesha; Arnold, David T; Stadon, Louise; Morley, Anna; Keenan, Emma; Darby, Michael; Armstrong, Lynne; Virgo, Paul; Maskell, Nick A

    2018-02-17

    Radiological monitoring of malignant pleural mesothelioma (MPM) using modified RECIST criteria is limited by low sensitivity and inter-observer variability. Serial serum mesothelin measurement has shown utility in the assessment of treatment response during chemotherapy but has never been assessed in the longer term follow up of patients. This is a single centre study of consecutive patients diagnosed with MPM who received chemotherapy or best supportive care (BSC). Serum mesothelin measurements with paired 6 monthly CT scans were performed following the completion of chemotherapy, or from baseline in the BSC group. Changes in mesothelin were correlated with radiological progression and overall survival. Forty-one patients with MPM were recruited and followed up for a minimum of 12 months (range 12-21 months). The majority of patients (n = 23) received chemotherapy with pemetrexed and cisplatin. Across the cohort a 10% rise in serum mesothelin could predict radiological progression with a sensitivity of 96% (IQR; 79-100) and specificity of 74% (IQR; 50-91). Sensitivity fell to 80% in sarcomatoid only disease. Patients with a rising mesothelin at 6 months had significantly worse overall survival (175 days) compared to stable/falling levels (448 days) (p = 0.003). This is the first study to assess serum mesothelin's ability to detect progression of MPM following chemotherapy or during BSC. A 10% rise in serum mesothelin level showed excellent sensitivity at predicting progressive disease. Mesothelin measurement has several advantages over serial CT imaging including reducing hospital visits and cost.

  8. In vivo serial sampling of epididymal sperm in mice.

    Science.gov (United States)

    Del Val, Gonzalo Moreno; Robledano, Patricia Muñoz

    2013-07-01

    This study was undertaken to refine the techniques of in vivo collection of sperm in the mouse. The principal objective was to offer a viable, safe and reliable method for serial collection of in vivo epididimary sperm through the direct puncture of the epididymis. Six C57Bl/6J males were subjected to the whole experiment. First we obtain a sperm sample of the right epididymis, and perform a vasectomy on the left side. This sample was used in an in vitro fertilization (IVF) experiment while the males were individually housed for 10 days to let them recover from the surgery, and then their fertility was tested with natural matings until we obtained a litter of each one. After that, the animals were subjected another time to the same process (sampling, recover and natural mating). The results of these experiments were a fertilization average value of 56.7%, and that all the males had a litter in the first month after the natural matings. This study documented the feasibility of the epididimary puncture technique to in vivo serial sampling of sperm in the mouse.

  9. Serial monitoring of Mucorales DNA load in serum samples of a patient with disseminated mucormycosis after allogeneic bone marrow transplantation.

    Science.gov (United States)

    Shigemura, Tomonari; Nakazawa, Yozo; Matsuda, Kazuyuki; Sano, Kenji; Yaguchi, Takashi; Motobayashi, Mitsuo; Saito, Shoji; Noda, Shunsuke; Kobayashi, Norimoto; Agematsu, Kazunaga; Honda, Takayuki; Koike, Kenichi

    2014-08-01

    Mucormycosis is a fatal complication in immunocompromised patients, and is additionally difficult to diagnose due to the lack of useful serum biomarkers. Using a quantitative PCR approach, we retrospectively analyzed Mucorales DNA load in sera collected serially from a 3-year-old patient with chronic granulomatous disease, who died of multi-organ failure probably due to dissemination of Rhizomucor pusillus, which was detected from necropsy specimens. Mucorales DNA load was below the detection limit on days 9, 2, and 4 after unrelated bone marrow transplantation. Rhizomucor DNA was first detected on day 14 (1.6 × 10(3) copies/mL), and subsequently fluctuated between 1.3 × 10(3) and 37.2 × 10(3) copies/mL until day 43. Rhizomucor achieved a peak value of 940.0 × 10(3) copies/mL on day 48 the day before death. The detection or fluctuation of Rhizomucor DNA appeared to be associated with corticosteroid dosages or C-reactive protein levels. This specific, noninvasive, and highly quantitative assay may be useful for the early diagnosis of mucormycosis and prediction of disease progression.

  10. Diagnosis of hepatocellular carcinoma by serial determination of serum alpha-fetoprotein concentration

    Energy Technology Data Exchange (ETDEWEB)

    Yumoto, Y; Namba, T; Tanaka, Y; Taketa, K; Ohta, Y [Okayama Univ. (Japan). School of Medicine

    1976-06-01

    This communication describes the clinical significance of serum ..cap alpha..-fetoprotein (S-AFP) determined by radioimmunoassay (RIA) in the diagnosis of hepatocellular carcinoma (HCC). The sensitivity of the AFP assay with the ..cap alpha..-Feto-125 kit produced by the Dainabot RI laboratories was over 2.5 ng/ml. Reproducibility of the kit was satisfactory; coefficient of variation was 6-10% within assays and 13% between assays. The mean and standard deviation of S-AFP in the sera of 30 healthy controls was 5.6+-2.6 ng/ml. When serum with a high level of S-AFP (2.9x10/sup 5/ ng/ml) was diluted with normal horse serum, the actual concentrations of AFP in the diluted serum were consistent with those determined. Thus, normal horse serum was employed to dilute the sera with high levels of AFP. Levels of S-AFP were over 2000 ng/ml in 75.5% of 49 cases with HCC, in 0.64% of 157 patients with hepatitis and cirrhosis of the liver, and in 3.8% of 52 cases of metastatic gastric cancer to the liver. In 20 patients with HCC, levels of S-AFP ranged widely from 7.5 to 9.5x10/sup 5/ ng/ml. In serial determinations of S-AFP in the clinical courses of patients such as those with S-AFP over 2000 ng/ml, the continuous increase of AFP was strongly suggestive of the presence of HCC. In 4 of 20 cases of HCC, the S-AFP levels remained under 300 ng/ml. Histological examination of these 4 cases of HCC showed Classes I and II, but no III in Edmondson's classification. Other cases of HCC with S-AFP levels over 300 ng/ml showed Edmondson's Classes II and III.

  11. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  12. The role of serial measurements of serum insulin-like growth factor 1 levels in the development of retinopathy of prematurity.

    Science.gov (United States)

    Dorum, Bayram Ali; Yılmaz, Cansu Canbolat; Köksal, Nilgün; Özkan, Hilal; Yıldız, Meral; Özmen, Ahmet Tuncer

    2017-03-01

    To determine the role of serum insulin-like growth factor-1 levels in the development of retinopathy of prematurity, which is a major cause of childhood blindness worldwide. We prospectively studied newborn infants born at a postmenstrual age of prematurity screening and follow-up. Retinopathy of prematurity was classified according to the international classification of retinopathy of prematurity. Serum Insulin like growth factor 1 levels were measured serially in blood samples on the 1 st , 3 rd , 7 th , 21 st , and 28 th day. Among the 40 infants, 11 (27.5%) constituted the retinopathy of prematurity group and 29 comprised the non-retinopathy of prematurity group. In the retinopathy of prematurity group, the mean gestational age and birth weight was significantly lower. The demographic features of the study cohort were similar. The duration of mechanical ventilation was significantly greater in the retinopathy of prematurity group compared with the non-retinopathy of prematurity group (p=0.036). In terms of neonatal morbidities such as respiratory distress syndrome, intraventricular hemorrhage, bronchopulmonary dysplasia, patent ductus arteriosus, and necrotizing enterocolitis, no differences were detected between the groups. The mean serum insulin-like growth factor-1 levels in retinopathy of prematurity group were significantly lower than those in the non-retinopathy of prematurity group at each time point (1 st , 3 rd , 7 th , 21 st , and 28 th day of postnatal life) (p=0.001). This study demonstrated the low serum insulin-like growth factor-1 levels was associated with retinopathy of prematurity development.

  13. Proton NMR-based metabolite analyses of archived serial paired serum and urine samples from myeloma patients at different stages of disease activity identifies acetylcarnitine as a novel marker of active disease.

    Directory of Open Access Journals (Sweden)

    Alessia Lodi

    Full Text Available BACKGROUND: Biomarker identification is becoming increasingly important for the development of personalized or stratified therapies. Metabolomics yields biomarkers indicative of phenotype that can be used to characterize transitions between health and disease, disease progression and therapeutic responses. The desire to reproducibly detect ever greater numbers of metabolites at ever diminishing levels has naturally nurtured advances in best practice for sample procurement, storage and analysis. Reciprocally, since many of the available extensive clinical archives were established prior to the metabolomics era and were not processed in such an 'ideal' fashion, considerable scepticism has arisen as to their value for metabolomic analysis. Here we have challenged that paradigm. METHODS: We performed proton nuclear magnetic resonance spectroscopy-based metabolomics on blood serum and urine samples from 32 patients representative of a total cohort of 1970 multiple myeloma patients entered into the United Kingdom Medical Research Council Myeloma IX trial. FINDINGS: Using serial paired blood and urine samples we detected metabolite profiles that associated with diagnosis, post-treatment remission and disease progression. These studies identified carnitine and acetylcarnitine as novel potential biomarkers of active disease both at diagnosis and relapse and as a mediator of disease associated pathologies. CONCLUSIONS: These findings show that samples conventionally processed and archived can provide useful metabolomic information that has important implications for understanding the biology of myeloma, discovering new therapies and identifying biomarkers potentially useful in deciding the choice and application of therapy.

  14. FREQUENCY OF ANEUPLOID SPERMATOZOA STUDIED BY MULTICOLOR FISH IN SERIAL SEMEN SAMPLES

    Science.gov (United States)

    Frequency of aneuploid spermatozoa studied by multicolor FISH in serial semen samplesM. Vozdova1, S. D. Perreault2, O. Rezacova1, D. Zudova1 , Z. Zudova3, S. G. Selevan4, J. Rubes1,51Veterinary Research Institute, Brno, Czech Republic; 2U.S. Environmental Protection A...

  15. Studies of serial serum electrophoretic pattern for prognosis in various cancer patients during irradiation

    International Nuclear Information System (INIS)

    Ra, Woo Youn; Woo, Won Hyung

    1971-01-01

    During the period from June. 1969 to Dec. 1970, the serum protein electrophoretic patterns of 44 cases of various cancer patients have been studied to determine the alterations in serum protein fractions in patients who were responding to irradiation or those failing. The serum electrophoretic pattern could be observed as an indicator of prognosis or radiosensitivity. A blood sample was obtained prior to any treatment and the follow up sampling was performed 2 times during radiation therapy. Serum total protein was determined by the method of Wolfson and serum electrophoresis was carried out by using Spinoco Model R B electrophoresis system. The results were following: Seven cases out of cases of cervical cancer responding favorably to radiotherapy showed decreased in Alpha-2 globulin fraction were increased. A case whose third time serum electrophoretic pattern showed multiple myeloma type died 5 months after radiotherapy with bone metastasis. Four cases out of 9 cases of favorably responded breast cancer patients showed decreased in Alpha-2 globulin foraction compared with 2 cases of unfavorable response showed increased in Alpha-2 globulin fraction

  16. Studies of serial serum electrophoretic pattern for prognosis in various cancer patients during irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ra, Woo Youn; Woo, Won Hyung [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    1971-10-15

    During the period from June. 1969 to Dec. 1970, the serum protein electrophoretic patterns of 44 cases of various cancer patients have been studied to determine the alterations in serum protein fractions in patients who were responding to irradiation or those failing. The serum electrophoretic pattern could be observed as an indicator of prognosis or radiosensitivity. A blood sample was obtained prior to any treatment and the follow up sampling was performed 2 times during radiation therapy. Serum total protein was determined by the method of Wolfson and serum electrophoresis was carried out by using Spinoco Model R B electrophoresis system. The results were following: Seven cases out of cases of cervical cancer responding favorably to radiotherapy showed decreased in Alpha-2 globulin fraction were increased. A case whose third time serum electrophoretic pattern showed multiple myeloma type died 5 months after radiotherapy with bone metastasis. Four cases out of 9 cases of favorably responded breast cancer patients showed decreased in Alpha-2 globulin foraction compared with 2 cases of unfavorable response showed increased in Alpha-2 globulin fraction.

  17. Metabolite characterization in serum samples from normal healthy ...

    African Journals Online (AJOL)

    Metabolite characterization in serum samples from normal healthy human subjects by 1H and 13C NMR spectroscopy. D Misra, U Bajpai. Abstract. One and two dimensional NMR spectroscopy has been employed to characterize the various metabolites of serum control healthy samples. Two dimensional heteronuclear ...

  18. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  19. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  20. Optical waveform sampling and error-free demultiplexing of 1.28 Tbit/s serial data in a silicon nanowire

    DEFF Research Database (Denmark)

    Ji, Hua; Hu, Hao; Galili, Michael

    2010-01-01

    We experimentally demonstrate 640 Gbit/s and 1.28 Tbit/s serial data optical waveform sampling and 640-to-10 Gbit/s and 1.28 Tbit/s-to-10 Gbit/s error-free demultiplexing using four-wave mixing in a 300nm$$450nm$$5mm silicon nanowire.......We experimentally demonstrate 640 Gbit/s and 1.28 Tbit/s serial data optical waveform sampling and 640-to-10 Gbit/s and 1.28 Tbit/s-to-10 Gbit/s error-free demultiplexing using four-wave mixing in a 300nm$$450nm$$5mm silicon nanowire....

  1. Changes in collagen metabolites in serum after cemented hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Joerring, S; Jensen, L T

    1993-01-01

    Markers of types I and III collagen turnover were measured in serial blood samples collected preoperatively and 60 days after surgery in 13 patients undergoing cemented total hip arthroplasty and 11 patients undergoing cemented total knee arthroplasty. The markers were the carboxyterminal extension....... We suggest that the changes in serum PICP and serum PIIINP reflect collagen formation in healing soft connective tissue 60 days after cemented hip or knee arthroplasty....

  2. Union Listing via OCLC's Serials Control Subsystem.

    Science.gov (United States)

    O'Malley, Terrence J.

    1984-01-01

    Describes library use of Conversion of Serials Project's (CONSER) online national machine-readable database for serials to create online union lists of serials via OCLC's Serial Control Subsystem. Problems in selection of appropriate, accurate, and authenticated records and prospects for the future are discussed. Twenty sources and sample records…

  3. Reconstruction of vessel structures from serial whole slide sections of murine liver samples

    Science.gov (United States)

    Schwier, Michael; Hahn, Horst K.; Dahmen, Uta; Dirsch, Olaf

    2013-03-01

    Image-based analysis of the vascular structures of murine liver samples is an important tool for scientists to understand liver physiology and morphology. Typical assessment methods are MicroCT, which allows for acquiring images of the whole organ while lacking resolution for fine details, and confocal laser scanning microscopy, which allows detailed insights into fine structures while lacking the broader context. Imaging of histological serial whole slide sections is a recent technology able to fill this gap, since it provides a fine resolution up to the cellular level, but on a whole organ scale. However, whole slide imaging is a modality providing only 2D images. Therefore the challenge is to use stacks of serial sections from which to reconstruct the 3D vessel structures. In this paper we present a semi-automatic procedure to achieve this goal. We employ an automatic method that detects vessel structures based on continuity and shape characteristics. Furthermore it supports the user to perform manual corrections where required. With our methods we were able to successfully extract and reconstruct vessel structures from a stack of 100 and a stack of 397 serial sections of a mouse liver lobe, thus proving the potential of our approach.

  4. Assessment of lectin and HILIC based enrichment protocols for characterization of serum glycoproteins by mass spectrometry

    DEFF Research Database (Denmark)

    Calvano, Cosima D; Zambonin, Carlo G; Jensen, Ole Nørregaard

    2008-01-01

    glycosylation profiles are associated with certain human ailments. Glycoprotein analysis by mass spectrometry of biological samples, such as blood serum, is hampered by sample complexity and the low concentration of the potentially informative glycopeptides and -proteins. We assessed the utility of lectin...... of 63 glycosylation sites in 38 proteins were identified by both methods, demonstrating distinct differences and complementarity. Serial application of custom-made microcolumns of mixed, immobilized lectins proved efficient for recovery and analysis of glycopeptides from serum samples of breast cancer...

  5. Clinical and anatomic pathology effects of serial blood sampling in rat toxicology studies, using conventional or microsampling methods.

    Science.gov (United States)

    Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique

    2015-08-01

    As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  7. Low-Z polymer sample supports for fixed-target serial femtosecond X-ray crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Feld, Geoffrey K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); National Institute of Environmental Health Science, Research Triangle Park, NC (United States); Heymann, Michael [Brandeis Univ., Waltham, MA (United States); Univ. of Hamburg and DESY, Hamburg (Germany); Benner, W. Henry [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pardini, Tommaso [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tsai, Ching -Ju [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Boutet, Sebastien [SLAC National Accelerator Lab., Menlo Park, CA (United States); Coleman, Matthew A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hunter, Mark S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); SLAC National Accelerator Lab., Menlo Park, CA (United States); Li, Xiaodan [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Messerschmidt, Marc [SLAC National Accelerator Lab., Menlo Park, CA (United States); BioXFEL Science and Technology Center, Buffalo, NY (United States); Opathalage, Achini [Brandeis Univ., Waltham, MA (United States); Pedrini, Bill [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Williams, Garth J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Krantz, Bryan A. [Univ. of California, Berkeley, CA (United States); Fraden, Seth [Brandeis Univ., Waltham, MA (United States); Hau-Riege, Stefan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Evans, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Segelke, Brent W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Frank, Matthias [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-27

    X-ray free-electron lasers (XFELs) offer a new avenue to the structural probing of complex materials, including biomolecules. Delivery of precious sample to the XFEL beam is a key consideration, as the sample of interest must be serially replaced after each destructive pulse. The fixed-target approach to sample delivery involves depositing samples on a thin-film support and subsequent serial introduction via a translating stage. Some classes of biological materials, including two-dimensional protein crystals, must be introduced on fixed-target supports, as they require a flat surface to prevent sample wrinkling. A series of wafer and transmission electron microscopy (TEM)-style grid supports constructed of low-Z plastic have been custom-designed and produced. Aluminium TEM grid holders were engineered, capable of delivering up to 20 different conventional or plastic TEM grids using fixed-target stages available at the Linac Coherent Light Source (LCLS). As proof-of-principle, X-ray diffraction has been demonstrated from two-dimensional crystals of bacteriorhodopsin and three-dimensional crystals of anthrax toxin protective antigen mounted on these supports at the LCLS. In conclusion, the benefits and limitations of these low-Z fixed-target supports are discussed; it is the authors' belief that they represent a viable and efficient alternative to previously reported fixed-target supports for conducting diffraction studies with XFELs.

  8. Comparison of miRNA quantitation by Nanostring in serum and plasma samples.

    Directory of Open Access Journals (Sweden)

    Catherine Foye

    Full Text Available Circulating microRNAs that are associated with specific diseases have garnered much attention for use in diagnostic assays. However, detection of disease-associated miRNA can be affected by several factors such as release of contaminating cellular miRNA during sample collection, variations due to amplification of transcript for detection, or controls used for normalization for accurate quantitation. We analyzed circulating miRNA in serum and plasma samples obtained concurrently from 28 patients, using a Nanostring quantitative assay platform. Total RNA concentration ranged from 32-125 μg/ml from serum and 30-220 μg/ml from plasma. Of 798 miRNAs, 371 miRNAs were not detected in either serum or plasma samples. 427 were detected in either serum or plasma but not both, whereas 151 miRNA were detected in both serum and plasma samples. The diversity of miRNA detected was greater in plasma than in serum samples. In serum samples, the number of detected miRNA ranged from 3 to 82 with a median of 17, whereas in plasma samples, the number of miRNA detected ranged from 25 to 221 with a median of 91. Several miRNA such as miR451a, miR 16-5p, miR-223-3p, and mir25-3p were highly abundant and differentially expressed between serum and plasma. The detection of endogenous and exogenous control miRNAs varied in serum and plasma, with higher levels observed in plasma. Gene expression stability identified candidate invariant microRNA that were highly stable across all samples, and could be used for normalization. In conclusion, there are significant differences in both the number of miRNA detected and the amount of miRNA detected between serum and plasma. Normalization using miRNA with constant expression is essential to minimize the impact of technical variations. Given the challenges involved, ideal candidates for blood based biomarkers would be those that are indifferent to type of body fluid, are detectable and can be reliably quantitated.

  9. Data-driven sampling method for building 3D anatomical models from serial histology

    Science.gov (United States)

    Salunke, Snehal Ulhas; Ablove, Tova; Danforth, Theresa; Tomaszewski, John; Doyle, Scott

    2017-03-01

    In this work, we investigate the effect of slice sampling on 3D models of tissue architecture using serial histopathology. We present a method for using a single fully-sectioned tissue block as pilot data, whereby we build a fully-realized 3D model and then determine the optimal set of slices needed to reconstruct the salient features of the model objects under biological investigation. In our work, we are interested in the 3D reconstruction of microvessel architecture in the trigone region between the vagina and the bladder. This region serves as a potential avenue for drug delivery to treat bladder infection. We collect and co-register 23 serial sections of CD31-stained tissue images (6 μm thick sections), from which four microvessels are selected for analysis. To build each model, we perform semi-automatic segmentation of the microvessels. Subsampled meshes are then created by removing slices from the stack, interpolating the missing data, and re-constructing the mesh. We calculate the Hausdorff distance between the full and subsampled meshes to determine the optimal sampling rate for the modeled structures. In our application, we found that a sampling rate of 50% (corresponding to just 12 slices) was sufficient to recreate the structure of the microvessels without significant deviation from the fullyrendered mesh. This pipeline effectively minimizes the number of histopathology slides required for 3D model reconstruction, and can be utilized to either (1) reduce the overall costs of a project, or (2) enable additional analysis on the intermediate slides.

  10. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  12. Optical Waveform Sampling and Error-Free Demultiplexing of 1.28 Tb/s Serial Data in a Nanoengineered Silicon Waveguide

    DEFF Research Database (Denmark)

    Ji, Hua; Pu, Minhao; Hu, Hao

    2011-01-01

    This paper presents the experimental demonstrations of using a pure nanoengineered silicon waveguide for 1.28 Tb/s serial data optical waveform sampling and 1.28 Tb/s–10 Gb/s error free demultiplexing. The 330-fs pulses are resolved in each 780-fs time slot in waveform sampling. Error...

  13. Serial changes of serum thyroid-stimulating hormone after total thyroidectomy or withdrawal of suppressive thyroxine therapy in patients with differentiated thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jin Ho; Lee, Jae Tae; Seo, Ji Hyoung [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-12-01

    Radioactive iodine (RAI) therapy and whole-body scanning are the fundamentals of treatment and follow-up of patients with differentiated thyroid cancer. It is generally accepted that a Thyroid-Stimulating Hormone (TSH) level of at least 30 {mu}U/ml is a prerequisite for the effective use of RAI, and that it requires 4-6 weeks of off-thyroxine to attain these levels. Because thyroxine withdrawal and the consequent hypothyroidism are often poorly tolerated, and occasionally might be hazardous, it is important to be certain that these assumptions are correct. We have measured serial changes in serum TSH after total thyroidectomy or withdrawl of thyroxine in patients with thyroid cancer. Serum TSH levels were measured weekly after thyroidectomy in 10 patients (group A) and after the discontinuation of thyroxine in 12 patients (group B). Symptoms and signs of hypothyroidism were also evaluated weekly by modified Billewicz diagnostic index. By the second week, 78% of group A patients and 17% of group B patients had serum TSH levels {>=} 30 {mu}U/ml. By the third week, 89% of group A patients and 90% of group B patients had serum TSH levels {>=} 30 {mu}U/ml. By the fourth week, all patients in two groups achieved target TSH levels and there were no overt hypothyroidism. In all patients, serum TSH elevated to the target concentration ({>=} 30 {mu}U/ml) within 4 weeks without significant manifestation of hypothyroidism. The schedule of RAI administration could be adjusted to fit. the needs and circumstances of individual patients with a shorter preparation period than the conventional.

  14. Nanoflow electrospinning serial femtosecond crystallography

    International Nuclear Information System (INIS)

    Sierra, Raymond G.; Laksmono, Hartawan; Kern, Jan; Tran, Rosalie; Hattne, Johan; Alonso-Mori, Roberto; Lassalle-Kaiser, Benedikt; Glöckner, Carina; Hellmich, Julia; Schafer, Donald W.; Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W.; Sellberg, Jonas; McQueen, Trevor A.; Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien; Zwart, Petrus H.; Glatzel, Pieter; Milathianaki, Despina; White, William E.; Adams, Paul D.; Williams, Garth J.; Boutet, Sébastien; Zouni, Athina; Messinger, Johannes; Sauter, Nicholas K.; Bergmann, Uwe; Yano, Junko; Yachandra, Vittal K.; Bogan, Michael J.

    2012-01-01

    A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min −1 to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min −1 and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption

  15. Nanoflow electrospinning serial femtosecond crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, Raymond G.; Laksmono, Hartawan [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Kern, Jan [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Tran, Rosalie; Hattne, Johan [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Alonso-Mori, Roberto [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Lassalle-Kaiser, Benedikt [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glöckner, Carina; Hellmich, Julia [Technische Universität Berlin, Strasse des 17 Juni 135, 10623 Berlin (Germany); Schafer, Donald W. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Sellberg, Jonas [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Stockholm University, S-106 91 Stockholm (Sweden); McQueen, Trevor A. [Stanford University, Stanford, CA 94025 (United States); Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Zwart, Petrus H. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glatzel, Pieter [European Synchrotron Radiation Facility, Grenoble (France); Milathianaki, Despina; White, William E. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Adams, Paul D. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Williams, Garth J.; Boutet, Sébastien [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Zouni, Athina [Technische Universität Berlin, Strasse des 17 Juni 135, 10623 Berlin (Germany); Messinger, Johannes [Umeå Universitet, Umeå (Sweden); Sauter, Nicholas K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bergmann, Uwe [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Yano, Junko; Yachandra, Vittal K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bogan, Michael J., E-mail: mbogan@slac.stanford.edu [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-11-01

    A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min{sup −1} to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min{sup −1} and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.

  16. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  17. Optimization of single plate-serial dilution spotting (SP-SDS) with sample anchoring as an assured method for bacterial and yeast cfu enumeration and single colony isolation from diverse samples.

    Science.gov (United States)

    Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S

    2015-12-01

    We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.

  18. Elevated serum leptin levels in patients with acute myocardial infarction; correlation with coronary angiographic and echocardiographic findings

    Directory of Open Access Journals (Sweden)

    Khafaji Hadi AR

    2012-05-01

    Full Text Available Abstract Background To assess the relationship between serial serum leptin levels in patients with acute myocardial infarction (AMI who received thrombolysis and the degree of coronary atherosclerosis, coronary reperfusion, echocardiographic findings, and clinical outcome. 51 consecutive patients presenting with AMI were studied. Clinical characteristics including age, sex, body mass index (BMI and cardiovascular risk factors were recorded. Serial serum leptin levels at the time of admission and subsequently at 0, 6, 12, 24, 36, 60 hours afterwards were obtained. Coronary angiography was performed in 34 patients; the relation between serum leptin levels and evidence of coronary reperfusion as well as the extent of coronary atherosclerosis according to the coronary artery surgery study classification (CASS were evaluated. Echocardiographic evaluation was performed in all patients. 36 matched patients were enrolled as control group who had serum leptin level 9.4 ± 6.5 ng/ml. Results The patients mean age was 50.5 ± 10.6 years. There were 47 males and 3 females. 37.1% were diabetics, 23.5% were hypertensive, 21.6% were dyslipidemic and 22.7% were obese (BMI ≥ 30. Leptin concentrations (ng/ml increased and peaked at the 4th sample (36 hrs after admission (mean ± SD sample (1 =9.55 ± 7.4, sample (2 =12.9 ± 8.4, sample (3 =13.8 ± 10.4, sample (4 =18.9 ± 18.1, sample (5 =11.4 ± 6.5, sample (6 =10.8 ± 8.9 ng/ml. There was a significant correlation between serum leptin and BMI (r = 0.342; p = 0.03. Leptin levels correlated significantly to creatine kinase level on the second day (r = 0.43, p ≤ 0.01. Significant correlation of mean serum leptin with the ejection fraction (P p = 0.8. There was a trend for an increase in the mean serum leptin levels with increasing number of diseased vessels. There was no correlation between serum leptin levels and outcome neither during the

  19. Reframing Serial Murder Within Empirical Research.

    Science.gov (United States)

    Gurian, Elizabeth A

    2017-04-01

    Empirical research on serial murder is limited due to the lack of consensus on a definition, the continued use of primarily descriptive statistics, and linkage to popular culture depictions. These limitations also inhibit our understanding of these offenders and affect credibility in the field of research. Therefore, this comprehensive overview of a sample of 508 cases (738 total offenders, including partnered groups of two or more offenders) provides analyses of solo male, solo female, and partnered serial killers to elucidate statistical differences and similarities in offending and adjudication patterns among the three groups. This analysis of serial homicide offenders not only supports previous research on offending patterns present in the serial homicide literature but also reveals that empirically based analyses can enhance our understanding beyond traditional case studies and descriptive statistics. Further research based on these empirical analyses can aid in the development of more accurate classifications and definitions of serial murderers.

  20. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  1. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  2. Serum endocan levels before and after surgery on low-grade gliomas.

    Science.gov (United States)

    Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda

    2017-01-01

    Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.

  3. Radioenzymatic assay for trimethoprim in very small serum samples.

    OpenAIRE

    Yogev, R; Melick, C; Tan-Pong, L

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved.

  4. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  5. Serial Entrepreneurship, Learning by Doing and Self-selection

    DEFF Research Database (Denmark)

    Rocha, Vera; Carneiro, Anabela; Varum, Celeste

    2015-01-01

    of the person-specific effect, using information on individuals’ past histories in paid employment, confirm that serial entrepreneurs exhibit, on average, a larger person-specific effect than non-serial business owners. Moreover, ignoring serial entrepreneurs’ self-selection overestimates learning by doing......It remains a question whether serial entrepreneurs typically perform better than their novice counterparts owing to learning by doing effects or mostly because they are a selected sample of higher-than-average ability entrepreneurs. This paper tries to unravel these two effects by exploring a novel...... empirical strategy based on continuous time duration models with selection. We use a large longitudinal matched employer-employee dataset that allows us to identify about 220,000 individuals who have left their first entrepreneurial experience, out of which over 35,000 became serial entrepreneurs. We...

  6. Suicide in serial killers.

    Science.gov (United States)

    Lester, David; White, John

    2010-02-01

    In a sample of 248 killers of two victims in America from 1900 to 2005, obtained from an encyclopedia of serial killers by Newton (2006), those completing suicide did not differ in sex, race, or the motive for the killing from those who were arrested.

  7. Serial killers with military experience: applying learning theory to serial murder.

    Science.gov (United States)

    Castle, Tammy; Hensley, Christopher

    2002-08-01

    Scholars have endeavored to study the motivation and causality behind serial murder by researching biological, psychological, and sociological variables. Some of these studies have provided support for the relationship between these variables and serial murder. However, the study of serial murder continues to be an exploratory rather than explanatory research topic. This article examines the possible link between serial killers and military service. Citing previous research using social learning theory for the study of murder, this article explores how potential serial killers learn to reinforce violence, aggression, and murder in military boot camps. As with other variables considered in serial killer research, military experience alone cannot account for all cases of serial murder. Future research should continue to examine this possible link.

  8. The relationship between serial sexual murder and autoerotic asphyxiation.

    Science.gov (United States)

    Myers, Wade C; Bukhanovskiy, Alexandr; Justen, Elle; Morton, Robert J; Tilley, John; Adams, Kenneth; Vandagriff, Virgil L; Hazelwood, Robert R

    2008-04-07

    This case series documents and examines the association between autoerotic asphyxiation, sadomasochism, and serial sexual murderers. Autoerotic asphyxiation, along with other paraphilias found in this population, is reviewed. Five cases of serial sexual killers who engaged in autoerotic asphyxiation were identified worldwide: four from the United States and one from Russia. Case reports for each are provided. All (100%) were found to have sexual sadism in addition to autoerotic asphyxiation. Furthermore, two (40%) had bondage fetishism, and two (40%) had transvestic fetishism, consistent with these paraphilias co-occurring in those with autoerotic asphyxiation. Overall the group averaged 4.0 lifetime paraphilias. Some possible relationships were observed between the offenders' paraphilic orientation and their modus operandi, e.g., all of these serial killers strangled victims-suggesting an association between their sadistic and asphyxiative paraphilic interests. The overlap of seemingly polar opposite paraphilias in this sample--sexual sadism and autoerotic asphyxiation--is explored from a historical and clinical perspective. Multiple commonalities shared between these five offenders and serial sexual murderers in general are addressed. A primary limitation of this study is its small sample size and empirical basis; the results may not be generalizable beyond the sample. The findings from this study support the supposition that crime scene behaviors often reflect paraphilic disturbances in those who commit serial sexual homicides.

  9. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  10. Female serial murderers: directions for future research on a hidden population.

    Science.gov (United States)

    Gurian, Elizabeth A

    2011-02-01

    This comprehensive overview on a sample of 65 cases (134 total offenders, including some partnered teams of more than 2 offenders) provides information on female serial murderers who either work in a mixed-sex offending group or alone. These female serial homicide offenders have a distinct set of offender-victim characteristics, including specific victim preferences, methods, and motivations: Partnered serial homicide offenders are more likely to target adult strangers and dispatch them using a combination of methods, whereas solo female serial murderers are most likely to target adult family members and murder them with poison. These patterns have the potential to add to our understanding of the possible similarities and differences of serial homicide cases by building on established offender characteristics. Convictions and sentences for the offenders are included and areas of future research and implications for treatment with this sample are also explored.

  11. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  12. Serum YKL-40 Predicts Relapse-Free and Overall Survival in Patients With American Joint Committee on Cancer Stage I and II Melanoma

    DEFF Research Database (Denmark)

    Schmidt, Henrik; Johansen, Julia S; Sjoegren, Pia

    2006-01-01

    level has been associated with poor prognosis in patients with several cancer types. PATIENTS AND METHODS: Serum samples from 234 patients with stage I (n = 162) and II (n = 72) melanoma were analyzed for YKL-40 by enzyme-linked immunosorbent assay. Serial samples were obtained before definitive primary...... surgery and during follow-up. RESULTS: After a median follow-up period of 66 months (range, 1 to 97 months), 41 relapses (18%) and 39 deaths (17%) were observed. Serum YKL-40 treated as an updated continuous covariate were analyzed together with the covariates sex, age, primary tumor site, ulceration...

  13. High biological variation of serum hyaluronic acid and Hepascore, a biochemical marker model for the prediction of liver fibrosis.

    Science.gov (United States)

    Rossi, Enrico; Adams, Leon A; Ching, Helena L; Bulsara, Max; MacQuillan, Gerry C; Jeffrey, Gary P

    2013-05-01

    Serum hyaluronic acid and biochemical models which require hyaluronic acid analysis are commonly used as predictors of liver fibrosis in patients with chronic liver disease, however biological variation data for hyaluronic acid are deficient. Four serial serum samples were obtained at weekly intervals from healthy volunteers and patients with chronic hepatitis B, chronic hepatitis C and non- alcoholic fatty liver disease (NAFLD; 20 in each group). The within-individual week-to-week variation (CVI) and reference change values for hyaluronic acid, α₂-macroglobulin and Hepascore were obtained. Hepascore is calculated from hyaluronic acid, α2-macroglobulin, bilirubin and γ-glutamyltransferase activity. Hyaluronic acid displayed large within-individual variation, the CVI values were 62% in healthy subjects, 38% in hepatitis C, 37% in hepatitis B and 36% in NAFLD patients. Hepascore CVIs were 43% in healthy subjects, 24% in hepatitis C, 28% in hepatitis B and 39% in NAFLD patients. α₂-Macroglobulin was much less variable with CVIs ranging from 4.4% to 7.6%. Bland-Altman plots of week-to-week variations showed rates of significant disagreement for samples collected in any 2 successive weeks varied from 5% in NAFLD patients to 8.3% in healthy subjects. When using non-fasting serum samples, hyaluronic acid and to a lesser extent, the Hepascore model display large within-individual variations in both health and chronic liver disease. This information is critical for interpreting the significance of both single measurements and changes in serial measurements.

  14. Total protein concentration and diagnostic test results for gray wolf (Canis lupus) serum using Nobuto filter paper strips

    Science.gov (United States)

    Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.

    2015-01-01

    Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.

  15. The influence of serial fecal sampling on the diagnosis of giardiasis in humans, dogs, and cats.

    Science.gov (United States)

    Uchôa, Flávia Fernandes de Mendonça; Sudré, Adriana Pittella; Macieira, Daniel de Barros; Almosny, Nádia Regina Pereira

    2017-08-24

    Giardia infection is a common clinical problem in humans and pets. The diagnosis of giardiasis is challenging as hosts intermittently excrete protozoan cysts in their feces. In the present study, we comparatively evaluated two methods of serial fecal sampling in humans, dogs, and cats from Rio de Janeiro, Brazil. The Faust et al. technique was used to examine fecal specimens collected in triplicate from 133 patients (52 humans, 60 dogs, and 21 cats). Specimens from 74 patients were received from the group assigned to carry out sampling on consecutive days - 34 humans, 35 dogs, and 5 cats, and specimens from 59 patients were received from the group assigned to carry out sampling on non-consecutive, separate days - 18 human beings, 25 dogs, and 16 cats. G. duodenalis cysts were found in stools of 30 individuals. Multiple stool sampling resulted in an increase in the number of samples that were positive for Giardia in both groups. The authors therefore conclude that multiple stool sampling increases the sensitivity of the Faust et al . technique to detect G. duodenalis cysts in samples from humans, cats and dogs.

  16. Inositol and hepatic lipidosis. I. Effect of inositol supplementation and time from parturition on liver and serum lipids in dairy cattle.

    Science.gov (United States)

    Gerloff, B J; Herdt, T H; Wells, W W; Liesman, J S; Emery, R S

    1986-06-01

    Percutaneous liver biopsies and blood samples were obtained from 80 multiparous dairy cows in nine Michigan herds. Biopsies and samples were obtained serially over the peripartum period. Thirty-nine cows received 17 g of supplemental myoinositol in the diet to test its use as a possible lipotropic substance and 41 received a placebo. Liver biopsies were assayed for triglyceride (TG) and total myoinositol content. Serum was assayed for dextran precipitable cholesterol and non-esterified fatty acids (NEFA). Inositol supplementation had no effect on any of the lipid variables. There was a significant herd effect on liver inositol, serum dextran precipitable cholesterol and NEFA concentrations. Serum NEFA and liver TG concentrations increased in the immediate postpartum period, while dextran precipitable cholesterol decreased. A significant herd X period interaction existed for liver TG and serum dextran precipitable cholesterol concentrations. Liver TG and serum NEFA concentrations were positively correlated. Excessive infiltration of bovine liver with lipid at calving appears to be an exaggerated manifestation of normal metabolic changes.

  17. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  18. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  19. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  20. Serial measurements of serum PDGF-AA, PDGF-BB, FGF2, and VEGF in multiresistant ovarian cancer patients treated with bevacizumab

    Directory of Open Access Journals (Sweden)

    Madsen Christine

    2012-09-01

    Full Text Available Abstract Introduction Anti-VEGF treatment has proven effective in recurrent ovarian cancer. However, the identification of the patients most likely to respond is still pending. It is well known that the angiogenesis is regulated by several other pro-angiogenic proteins, e.g. the platelet - derived growth factor (PDGF system and the fibroblast growth factor (FGF system. These other signaling pathways may remain active or become upregulated during anti-VEGF treatment. The aim of the present study was to investigate if potential changes of PDGF-BB, PDGF-AA, and FGF2 before and during bevacizumab treatment had predictive value for early progression or survival. Furthermore, we wanted to investigate the importance of serum VEGF in the same cohort. Methods This study included 106 patients with chemotherapy-resistant epithelial ovarian cancer who were treated with single agent bevacizumab as part of a biomarker protocol. Patients were evaluated for response by the Response Evaluation Criteria In Solid Tumors (RECIST and/ or Gynecologic Cancer Intergroup (GCIG CA125 criteria. Serum samples were collected at baseline and prior to each treatment. FGF2, PDGF-BB, PDGF-AA were quantified simultaneously using the Luminex system, and VEGF-A was measured by ELISA. Eighty-eight baseline samples were avaliable for FGF2, PDGF-BB, PDGF-AA analysis, and 93 baseline samples for VEGF. Results High baseline serum VEGF was related to poor overall survival. Furthermore, high serum PDGF-BB and FGF2 was of prognostic significance. None of the markers showed predictive value, neither at baseline level nor during the treatment.

  1. [A study of growth and malignancy grading of stomach and colorectal cancers by serial serum carcinoembryonic antigen levels analysis].

    Science.gov (United States)

    Umehara, Y; Miyahara, T; Yoshida, M; Isobe, S; Oba, N; Harada, Y

    1990-06-01

    Changes in serum CEA levels were analyzed on a time-course basis in 33 patients with stomach cancer and 20 patients with colorectal cancer. A linear relationship between log CEA and time could be evaluated and individual CEA doubling time (CEA D.T.) was calculated. The results obtained are as follows. 1) The CEA D.T. was not constant from the onset of the disease to death in stomach cancer and colorectal cancer. 2) The CEA D.T. was distributed widely with 5 to 140 days in stomach cancer and 8 to 134 days in colorectal cancer. It tended to be shortened at the terminal stage in both tumors. 3) In terms of age, sex and histology, the CEA D.T. tended to be short in the young, female and poorly differentiated cancer. These background appeared to have an influence on the growth of tumor. 4) The CEA D.T. was well correlated with the period of survival of the patients with gastric cancer (r = 0.636, p less than 0.001). The analysis of serial CEA levels on a time-course basis is considered useful in studying the relationship between tumor-bearing hosts and malignancy of the tumor.

  2. Taking serial correlation into account in tests of the mean

    International Nuclear Information System (INIS)

    Zwiers, F.W.; Storch, H. von

    1993-01-01

    The comparison of means derived from samples of noisy data is a standard part of climatology. When the data are not serially correlated the appropriate statistical tool for this task is usually the conventional Student's t-test. However, data frequently are serially correlated in climatological applications with the result that the t-tests in its standard form is not applicable. The usual solution to this problem is to scale the t-statistic by a factor which depends upon the equivalent sample size n e . We show, by means of simulations, that the revised t-test is often conservative (the actual significance level is smaller than the specified significance level) when the equivalent sample size is known. However, in most practical cases the equivalent sample size is not known. Then the test becomes liberal (the actual significance level is greater than the specified significance level). This systematic error becomes small when the true equivalent sample size is large (greater than approximately 30). We re-examine the difficulties inherent in difference of means tests when there is serial dependence. We provide guidelines for the application of the 'usual' t-test and propose two alternative tests which substantially improve upon the 'usual' t-test when samples are small. (orig.)

  3. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  4. Serum copper levels in users of multiload intra-uterine contraceptive devices.

    Science.gov (United States)

    Arowojolu, A O; Otolorin, E O; Ladipo, O A

    1989-12-01

    The systemic absorption of copper incorporated into multiload intra-uterine contraceptive devices (IUDs), as indicated by serum copper levels in users of such devices, was assessed in a prospective longitudinal study. One hundred and ten healthy Nigerian women using either multiload copper 250 (MLCU 250) or multiload copper 375 (MLCU 375) IUDs participated in the study. Their serum copper levels were estimated serially during 12 months of continuous use of the devices. The mean (+/- s.e.m.) pre-insertion serum copper levels of our subjects using MLCU 250 (17.0 +/- 3 mumol/l) and MLCU 375 (16.7 +/- 0.5 mumol/l) were found to be lower than those reported in Americans (22.2 mumol/l) and in Germans (20.2 mumol/l), although similar to levels in Indians (17.0 mumol/l). There was no significant difference in the mean serum copper levels estimated before and after 1 month of continuous use of the device. Serial estimations of the serum copper levels in users showed that there was no alteration in these levels after a period of 12 months of continuous IUD use. We therefore conclude that the copper incorporated into multiload IUDs appears not to influence the concentration of serum copper of users.

  5. Decreasing Serial Cost Sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Østerdal, Lars Peter

    The increasing serial cost sharing rule of Moulin and Shenker [Econometrica 60 (1992) 1009] and the decreasing serial rule of de Frutos [Journal of Economic Theory 79 (1998) 245] have attracted attention due to their intuitive appeal and striking incentive properties. An axiomatic characterization...... of the increasing serial rule was provided by Moulin and Shenker [Journal of Economic Theory 64 (1994) 178]. This paper gives an axiomatic characterization of the decreasing serial rule...

  6. Decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Østerdal, Lars Peter Raahave

    2009-01-01

    The increasing serial cost sharing rule of Moulin and Shenker (Econometrica 60:1009-1037, 1992) and the decreasing serial rule of de Frutos (J Econ Theory 79:245-275, 1998) are known by their intuitive appeal and striking incentive properties. An axiomatic characterization of the increasing serial...... rule was provided by Moulin and Shenker (J Econ Theory 64:178-201, 1994). This paper gives an axiomatic characterization of the decreasing serial rule....

  7. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  8. Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples

    Directory of Open Access Journals (Sweden)

    Samira Moraes Cunha de Mesquita

    2015-06-01

    Full Text Available ABSTRACT. Mesquita S.M.C., Mansur F.J., Nascimento E.R., Barreto M.L. & Kimura L.M.S. [Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples.] Padroniza- ção e aplicação de ELISA indireto para diagnóstico de Mycoplasma bovis em amostras de soro sanguíneo bovino. Revista Brasileira de Medicina Veterinária, 37(2:101-107, 2015. Universidade Federal Fluminense, Faculdade de Veteriná- ria, Rua Vital Brazil Filho, 64, Vital Brazil, Niterói, RJ 24230-340, Brasil. E-mail: samira.veterinaria@gmail.com International researchers presented results indicating frequent involvement of Mycoplasma spp. as a causative agent of mastitis in cattle, associating its presence with significant economic losses to farmers. Mycoplasma bovis is the species most reported and relevant, because it causes more severe disease. The level of antibodies against M. bovis remains high for several months and can be detected by ELISA. The aim of this work was to develop an indirect ELISA with whole cell antigen of M. bovis (strain Donetta PG 45 with subsequent application in bovine blood serum samples for detection of antibodies against M. bovis. The immunization of cows A and B by inoculating an immunogen against M. bovis to obtain hyperimmune blood serum was the first stage of this work, then the stage of standardization of ELISA was proceeded. The concentration of 2 mg of antigen/mL for coating the microtiter plates was decided by statistical analyses. The optical density value 0,2 was determined as the limit of reactivity discrimination of samples (the cut-off point. The hyperimmune blood serum sample of the cow A (collected 30 days after immunization was chosen as the positive control and, the fetal calf serum was chosen as negative control of the assay. In addition, the ideal optimal dilutions found for blood serum samples was 1:400 and for conjugate was 1:10.000 and the substrate used was the ortho

  9. Retrospective analysis of dengue specific IgM reactive serum samples

    OpenAIRE

    Nemai Bhattacharya; Bhaswati Bandyopadhyay; Indranil Bhattacharjee; Hiranmoy Mukherjee; Srabani Talukdar; Ruby Mondal; Netai Pramanick; Goutam Chandra; Amiya K. Hati

    2013-01-01

    Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1) antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: Th...

  10. Broad ion beam serial section tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, B., E-mail: b.winiarski@manchester.ac.uk [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Materials Division, National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Gholinia, A. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Mingard, K.; Gee, M. [Materials Division, National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Thompson, G.E.; Withers, P.J. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom)

    2017-01-15

    Here we examine the potential of serial Broad Ion Beam (BIB) Ar{sup +} ion polishing as an advanced serial section tomography (SST) technique for destructive 3D material characterisation for collecting data from volumes with lateral dimensions significantly greater than 100 µm and potentially over millimetre sized areas. Further, the associated low level of damage introduced makes BIB milling very well suited to 3D EBSD acquisition with very high indexing rates. Block face serial sectioning data registration schemes usually assume that the data comprises a series of parallel, planar slices. We quantify the variations in slice thickness and parallelity which can arise when using BIB systems comparing Gatan PECS and Ilion BIB systems for large volume serial sectioning and 3D-EBSD data acquisition. As a test case we obtain 3D morphologies and grain orientations for both phases of a WC-11%wt. Co hardmetal. In our case we have carried out the data acquisition through the manual transfer of the sample between SEM and BIB which is a very slow process (1–2 slice per day), however forthcoming automated procedures will markedly speed up the process. We show that irrespective of the sectioning method raw large area 2D-EBSD maps are affected by distortions and artefacts which affect 3D-EBSD such that quantitative analyses and visualisation can give misleading and erroneous results. Addressing and correcting these issues will offer real benefits when large area (millimetre sized) automated serial section BIBS is developed. - Highlights: • In this work we examine how microstructures can be reconstructed in three-dimensions (3D) by serial argon broad ion beam (BIB) milling, enabling much larger volumes (>250×250×100µm{sup 3}) to be acquired than by serial section focused ion beam-scanning electron microscopy (FIB-SEM). • The associated low level of damage introduced makes BIB milling very well suited to 3D-EBSD acquisition with very high indexing rates. • We explore

  11. Nanoflow electrospinning serial femtosecond crystallography

    Science.gov (United States)

    Sierra, Raymond G.; Laksmono, Hartawan; Kern, Jan; Tran, Rosalie; Hattne, Johan; Alonso-Mori, Roberto; Lassalle-Kaiser, Benedikt; Glöckner, Carina; Hellmich, Julia; Schafer, Donald W.; Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W.; Sellberg, Jonas; McQueen, Trevor A.; Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien; Zwart, Petrus H.; Glatzel, Pieter; Milathianaki, Despina; White, William E.; Adams, Paul D.; Williams, Garth J.; Boutet, Sébastien; Zouni, Athina; Messinger, Johannes; Sauter, Nicholas K.; Bergmann, Uwe; Yano, Junko; Yachandra, Vittal K.; Bogan, Michael J.

    2012-01-01

    An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min−1 to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min−1 and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption. PMID:23090408

  12. A prospective cohort study of biomarkers of prenatal tobacco smoke exposure: the correlation between serum and meconium and their association with infant birth weight

    Directory of Open Access Journals (Sweden)

    Braun Joe M

    2010-08-01

    Full Text Available Abstract Background The evaluation of infant meconium as a cumulative matrix of prenatal toxicant exposure requires comparison to established biomarkers of prenatal exposure. Methods We calculated the frequency of detection and concentration of tobacco smoke metabolites measured in meconium (nicotine, cotinine, and trans-3'-hydroxycotinine concentrations and three serial serum cotinine concentrations taken during the latter two-thirds of pregnancy among 337 mother-infant dyads. We estimated the duration and intensity of prenatal tobacco smoke exposure using serial serum cotinine concentrations and calculated geometric mean meconium tobacco smoke metabolite concentrations according to prenatal exposure. We also compared the estimated associations between these prenatal biomarkers and infant birth weight using linear regression. Results We detected nicotine (80%, cotinine (69%, and trans-3'-hydroxycotinine (57% in most meconium samples. Meconium tobacco smoke metabolite concentrations were positively associated with serum cotinine concentrations and increased with the number of serum cotinine measurements consistent with secondhand or active tobacco smoke exposure. Like serum cotinine, meconium tobacco smoke metabolites were inversely associated with birth weight. Conclusions Meconium is a useful biological matrix for measuring prenatal tobacco smoke exposure and could be used in epidemiological studies that enroll women and infants at birth. Meconium holds promise as a biological matrix for measuring the intensity and duration of environmental toxicant exposure and future studies should validate the utility of meconium using other environmental toxicants.

  13. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  14. Resolution of a serum sample mix-up through the use of short tandem repeat DNA typing.

    Science.gov (United States)

    Allen, Robert W; Pritchard, Jane K

    2004-12-01

    A sample mix-up occurred in a tissue procurement laboratory in which aliquots of serum from two tissue donors were accidentally mislabeled. The clues to the apparent mixup involved discrepant Hepatitis C test results. In an attempt to resolve the apparent mix up, DNA typing was performed using serum samples as a possible source of genomic DNA. Two hundred microliter aliquots of two reference sera and aliquots prepared from them were subjected to DNA extraction. PCR amplification of 9 STR loci was performed on the extracts and amplicons were analyzed by capillary electrophoresis. About 1 microg/ml of DNA was recovered from all serum samples and was of sufficient quality to direct the amplification of most, if not all STR loci allowing the mislabeled specimens to be traced to the proper tissue donor. Serum is a useful source of genomic DNA for STR analysis in situations in which such samples are the only source of DNA for testing. Interestingly, one of the tissue donors on life support and repeatedly receiving blood products, exhibited a mixed DNA profile indicative of the presence of DNA from multiple individuals in the bloodstream.

  15. High-performance serial block-face SEM of nonconductive biological samples enabled by focal gas injection-based charge compensation.

    Science.gov (United States)

    Deerinck, T J; Shone, T M; Bushong, E A; Ramachandra, R; Peltier, S T; Ellisman, M H

    2018-05-01

    A longstanding limitation of imaging with serial block-face scanning electron microscopy is specimen surface charging. This charging is largely due to the difficulties in making biological specimens and the resins in which they are embedded sufficiently conductive. Local accumulation of charge on the specimen surface can result in poor image quality and distortions. Even minor charging can lead to misalignments between sequential images of the block-face due to image jitter. Typically, variable-pressure SEM is used to reduce specimen charging, but this results in a significant reduction to spatial resolution, signal-to-noise ratio and overall image quality. Here we show the development and application of a simple system that effectively mitigates specimen charging by using focal gas injection of nitrogen over the sample block-face during imaging. A standard gas injection valve is paired with a precisely positioned but retractable application nozzle, which is mechanically coupled to the reciprocating action of the serial block-face ultramicrotome. This system enables the application of nitrogen gas precisely over the block-face during imaging while allowing the specimen chamber to be maintained under high vacuum to maximise achievable SEM image resolution. The action of the ultramicrotome drives the nozzle retraction, automatically moving it away from the specimen area during the cutting cycle of the knife. The device described was added to a Gatan 3View system with minimal modifications, allowing high-resolution block-face imaging of even the most charge prone of epoxy-embedded biological samples. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  16. Usefulness of in-house real time PCR for HBV DNA quantification in serum and oral fluid samples.

    Science.gov (United States)

    Portilho, Moyra Machado; Mendonça, Ana Carolina da Fonseca; Bezerra, Cristianne Sousa; do Espirito-Santo, Márcia Paschoal; de Paula, Vanessa Salete; Nabuco, Leticia Cancella; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2018-06-01

    For quantification of hepatitis B virus DNA (HBV DNA), commercial assays are used with serum or plasma samples, but oral fluid samples could be an alternative for HBV diagnosis due to ease of collection. This study aims to develop in-house real time PCR using synthetic curve for HBV DNA quantification for serum and oral fluid samples. Samples were collected from 103 individuals (55 HBsAg reactive and HBV DNA reactive by commercial assay and 48 without HBV markers) and submitted to two in-house real time PCR assays for HBV pre-S/S region with different standard curves: qPCR plasmidial and qPCR synthetic. A total of 27 serum samples were HBV DNA positive by qPCR plasmidial and 40 with qPCR synthetic (72% and 85% of concordance, respectively). Quantitative PCR synthetic presented efficiency of 99% and sensitivity of 2log10 copies/mL. Among oral fluid samples, five and ten were detected using qPCR plasmidial and synthetic, respectively. This study demonstrated that qPCR synthetic using serum samples could be used as alternative for HBV DNA quantification due to its sensitivity. In addition, it was possible to quantify HBV DNA in oral fluid samples suggesting the potential of this specimen for molecular diagnosis of HBV. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Serial cytokine alterations and abnormal neuroimaging in newborn infants with encephalopathy.

    Science.gov (United States)

    O'Hare, Fiona M; Watson, R William G; O'Neill, Amanda; Segurado, Ricardo; Sweetman, Deirdre; Downey, Paul; Mooney, Eoghan; Murphy, John; Donoghue, Veronica; Molloy, Eleanor J

    2017-04-01

    Inflammatory cytokines may play a role in the final common pathway in the pathogenesis of hypoxic-ischaemic injury in experimental models. We aimed to profile the systemic pro-and anti-inflammatory response over the first week of life in term infants at risk of neonatal encephalopathy. In a tertiary referral university neonatal intensive care unit, serial blood samples were analysed from 41 term infants (requiring resuscitation at birth) in this prospective observational pilot study. Serum levels of 10 pro-and anti-inflammatory cytokines were evaluated including interleukin(IL)-1α, IL-1β, IL-6, IL-8, IL-10, tumour necrosis factor(TNF)-α, interferon (IFN)-γ, vascular endothelial growth factor (VEGF), granulocyte/colony-stimulating factor (G-CSF) and granulocyte macrophage/colony-stimulating factor (GM-CSF). Infants with neonatal encephalopathy and abnormal neuroimaging (n = 15) had significantly elevated granulocyte macrophage/colony-stimulating factor at 0-24 h and interleukin-8, interleukin-6 and interleukin-10 at 24-48 hour. Tumour necrosis factor-α and vascular endothelial growth factor levels were lower at 72-96 hour (p < 0.05). Significantly elevated levels of interleukin-10 were associated with mortality. Serum cytokine changes and innate immune dysregulation in the first week of life may be indicators of outcome in neonatal encephalopathy but require validation in larger studies. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  18. Serum thromboxane B2 (TXB2 Determination is Influenced by Sample Incubation Temperature in Healthy Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Aleš Jerin

    2009-01-01

    Full Text Available The measurement of serum thromboxane B2 (TXB2 production by platelets is a specific test for assessment of platelet cyclooxygenase (COX-1 activity following administration of non-steroidal anti-inflammatory drugs (NSAIDs. The aim of this study was to investigate the influence of sample incubation at 37 °C for one hour on serum TXB2 concentration in comparison with incubation at room temperature. A total of 54 blood samples for serum TXB2 measurements were collected from six healthy beagle dogs into two separate serum tubes. While one group of tubes was incubated in a 37 °C water bath, the second group of tubes was left to coagulate at room temperature, both for one hour. Serum TXB2 concentrations were measured by ELISA. The mean concentration (± SD of serum TXB2 in the group of samples that were incubated at 37 °C was significantly (P 2 concentration in healthy beagle dogs and demonstrate that validated methods for assessment of COX-1 activity by measurement of serum TXB2 should be used in order to make results more reliable and comparable between different studies. The results of this study might be of great help in planning NSAID studies in dogs by providing the information that TXB2 generation by platelets is influenced profoundly by incubation temperature.

  19. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.

    Science.gov (United States)

    Govorukhina, N I; Reijmers, T H; Nyangoma, S O; van der Zee, A G J; Jansen, R C; Bischoff, R

    2006-07-07

    Discovery of biomarkers is a fast developing field in proteomics research. Liquid chromatography coupled on line to mass spectrometry (LC-MS) has become a powerful method for the sensitive detection, quantification and identification of proteins and peptides in biological fluids like serum. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomics studies. To perform future comparative analyses of samples from a serum bank of cervical cancer patients in a longitudinal and cross-sectional manner, methodology based on the depletion of high-abundance proteins followed by tryptic digestion and LC-MS has been developed. Two sample preparation methods were tested in terms of their efficiency to deplete high-abundance serum proteins and how they affect the repeatability of the LC-MS data sets. The first method comprised depletion of human serum albumin (HSA) on a dye ligand chromatographic and immunoglobulin G (IgG) on an immobilized Protein A support followed by tryptic digestion, fractionation by cation-exchange chromatography, trapping on a C18 column and reversed-phase LC-MS. The second method included depletion of the six most abundant serum proteins based on multiple immunoaffinity chromatography followed by tryptic digestion, trapping on a C18 column and reversed-phase LC-MS. Repeatability of the overall procedures was evaluated in terms of retention time and peak area for a selected number of endogenous peptides showing that the second method, besides being less time consuming, gave more repeatable results (retention time: <0.1% RSD; peak area: <30% RSD). Application of an LC-MS component detection algorithm followed by principal component analysis (PCA) enabled discrimination of serum samples that were spiked with horse heart cytochrome C from non-spiked serum and the detection of a concentration trend, which correlated to the amount of spiked horse heart

  20. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  1. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  2. Serial position markers in space: visuospatial priming of serial order working memory retrieval.

    Directory of Open Access Journals (Sweden)

    Maya De Belder

    Full Text Available Most general theories on serial order working memory (WM assume the existence of position markers that are bound to the to-be-remembered items to keep track of the serial order. So far, the exact cognitive/neural characteristics of these markers have remained largely underspecified, while direct empirical evidence for their existence is mostly lacking. In the current study we demonstrate that retrieval from verbal serial order WM can be facilitated or hindered by spatial cuing: begin elements of a verbal WM sequence are retrieved faster after cuing the left side of space, while end elements are retrieved faster after cuing the right side of space. In direct complement to our previous work--where we showed the reversed impact of WM retrieval on spatial processing--we argue that the current findings provide us with a crucial piece of evidence suggesting a direct and functional involvement of space in verbal serial order WM. We outline the idea that serial order in verbal WM is coded within a spatial coordinate system with spatial attention being involved when searching through WM, and we discuss how this account can explain several hallmark observations related to serial order WM.

  3. Quality assesment for the analysis of PCDDs/PCDFs in individual human serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Perez, F [IIQAB-CSIC, Barcelona (Spain). Dept. of Ecotechnologies, Lab. of Dioxins; Abad, E; Llerena, J J; Caixach, J; Rivera, J

    2004-09-15

    The aim of this work was to optimise a relevant methodology for the ultratrace analysis of PCDDs/PCDFs in individual human serum samples. In order to carry out the study, different strategies including the elaboration of quality control samples, parallel sample analysis, control blanks and a number of quality assurance measures were implemented as analytical current practices. Some of the main drawbacks in the analysis of PCDDs/PCDFs in these kind of samples come from two conflicting aspects: the small sample size and the low levels expected to be found. Taking this into account, an unavoidable compromise between the sample amount and the minimum analytical requirements, mainly the detection limit (LOD), is mandatory. To reach this goal C{sub 18} solid phase extraction was used to remove the analytes from the matrix. Clean up was performed by solid-liquid adsorption chromatography using a variety of adsorbents. Instrumental analysis was achieved by high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). Finally, the optimised methodology was applied to evaluate the potential impact in general population living in the surroundings of an obsolete municipal waste incinerator plant (MWI). Thus, more than 400 individuals serum samples potentially exposed to the emission of the incinerator and people not exposed were considered in this study.

  4. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  5. Automated blood-sample handling in the clinical laboratory.

    Science.gov (United States)

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  6. Diagnostic value of serial measurement of C-reactive protein in serum and matrix metalloproteinase-9 in drainage fluid in the detection of infectious complications and anastomotic leakage in patients with colorectal resection.

    Science.gov (United States)

    Kostić, Zoran; Panišić, Marina; Milev, Boško; Mijušković, Zoran; Slavković, Damjan; Ignjatović, Mile

    2015-10-01

    Postoperative infectious complications are one of the most important problems in surgical treatment of colorectal cancer (CRC), being present in up to 40% of patients. The aim of this paper was to establish the significance of serial measurement of C-reactive protein (CRP) in serum and matrix metalloproteinase-9 (MMP-9) in drainage fluid for the detection of infectious complications and anastomotic leakage (AL) in patients with colorectal resection. CRP and MMP-9 values in serum and drainage fluid, respectively, were measured on the first, third, fifth, and seventh postoperative day (POD) in 150 patients with colorectal resection and primary anastomosis. The values obtained were compared between the patients without complicatons and those with surgical site and remote infections and AL. Surgical site infections (SSIs) were observed in 41 (27.3%), and remote infections in 10 (6.7%) patients. Clinically evident AL was observed in 15 (10/6) patients. In 82% of the patients with SSIs, serum CRP value on POD 5 exceeded 82 mg/L, with 81% specificity. AL was reported in 85% and 92% of the patients on PODs 5 and 7, respectively, with CRP values of 77 mg/L and 90 mg/L, respectively. The specificity was 77% for POD 5 and 88% for POD 7. All the patients with CRP values exceeding 139 mg/L on POD 5 had some of SSIs and/or AL. The mean values of MMP-9 were not statistically different between the group without complications (n = 99) and the group with AL (n = 15). Serial measurement of CRP is recommended for screening of infectious complications of colorectal resection. Patients with CRP values above 139 mg/L on POD 5 cannot be discharged from hospital, and require an intensive search for infectious complications, particularly AL. MMP-9 measurement in drainage fluid is not relevant in the detection of AL in patients with colorectal resection.

  7. Serial Expression Analysis: a web tool for the analysis of serial gene expression data

    Science.gov (United States)

    Nueda, Maria José; Carbonell, José; Medina, Ignacio; Dopazo, Joaquín; Conesa, Ana

    2010-01-01

    Serial transcriptomics experiments investigate the dynamics of gene expression changes associated with a quantitative variable such as time or dosage. The statistical analysis of these data implies the study of global and gene-specific expression trends, the identification of significant serial changes, the comparison of expression profiles and the assessment of transcriptional changes in terms of cellular processes. We have created the SEA (Serial Expression Analysis) suite to provide a complete web-based resource for the analysis of serial transcriptomics data. SEA offers five different algorithms based on univariate, multivariate and functional profiling strategies framed within a user-friendly interface and a project-oriented architecture to facilitate the analysis of serial gene expression data sets from different perspectives. SEA is available at sea.bioinfo.cipf.es. PMID:20525784

  8. Short- and long-term memory contributions to immediate serial recognition: evidence from serial position effects.

    Science.gov (United States)

    Purser, Harry; Jarrold, Christopher

    2010-04-01

    A long-standing body of research supports the existence of separable short- and long-term memory systems, relying on phonological and semantic codes, respectively. The aim of the current study was to measure the contribution of long-term knowledge to short-term memory performance by looking for evidence of phonologically and semantically coded storage within a short-term recognition task, among developmental samples. Each experimental trial presented 4-item lists. In Experiment 1 typically developing children aged 5 to 6 years old showed evidence of phonologically coded storage across all 4 serial positions, but evidence of semantically coded storage at Serial Positions 1 and 2. In a further experiment, a group of individuals with Down syndrome was investigated as a test case that might be expected to use semantic coding to support short-term storage, but these participants showed no evidence of semantically coded storage and evidenced phonologically coded storage only at Serial Position 4, suggesting that individuals with Down syndrome have a verbal short-term memory capacity of 1 item. Our results suggest that previous evidence of semantic effects on "short-term memory performance" does not reflect semantic coding in short-term memory itself, and provide an experimental method for researchers wishing to take a relatively pure measure of verbal short-term memory capacity, in cases where rehearsal is unlikely.

  9. Fluoride therapy for osteoporosis: characterization of the skeletal response by serial measurements of serum alkaline phosphatase activity.

    Science.gov (United States)

    Farley, S M; Wergedal, J E; Smith, L C; Lundy, M W; Farley, J R; Baylink, D J

    1987-03-01

    Optimum use of fluoride therapy for osteoporosis requires a sensitive and convenient index of the skeletal response to fluoride. Since previous studies had shown that serum alkaline phosphatase activity (SALP) was increased in response to fluoride therapy, we examined serial measurements of SALP in 53 osteoporotics treated with 66 to 110 mg of sodium fluoride (NaF) for 12 to 91 months. SALP was increased in 87% of the subjects during therapy with fluoride. The increase in SALP was thought to reflect the osteogenic action of fluoride based on the findings that SALP correlated with both trabecular bone area (r = .81, P less than .001) and osteoid length (r = .67, P less than .01) in iliac crest biopsies, predicted increased bone density on spinal radiographs in response to fluoride therapy with an 87% accuracy, and predicted decreased back pain in response to fluoride with a 91% accuracy. In addition, the SALP response to fluoride was seen earlier than other therapeutic responses as indicated by the findings that the tau 1/2 for the SALP response (ie, time for 1/2 of the patients to show a significant response) was significantly less (1.2 +/- 0.3 yr) than that for the pain response (1.6 +/- 0.3 yr, P less than .05) or that for the radiographic response (3.7 +/- 0.5 yr, P less than .001). Although most patients responded to fluoride with an increase in SALP, evaluation of the kinetics of the SALP response to fluoride revealed marked interpatient variation.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Developments in Serials: 1977

    Science.gov (United States)

    James, John R.

    1978-01-01

    Discusses issues and developments relating to several aspects of serials, including economics and acquisitions; bibliographic control; automation; education; serials literature and bibliographies; and copyrights. A bibliography is included. (Author/MBR)

  11. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  12. Malaysian Serials: Issues and Problems.

    Science.gov (United States)

    Bahri, Che Norma

    This paper analyzes the issues and problems while looking at the trends and developments of serials publishing in Malaysia. The first section provides background; topics addressed include the country and people of Malaysia, the history of serials publishing in Malaysia, categories and formats of serials publishing, academic publications,…

  13. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  14. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  15. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  16. Chemometrics enhanced HPLC-DAD performance for rapid quantification of carbamazepine and phenobarbital in human serum samples.

    Science.gov (United States)

    Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh

    2014-02-01

    This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  17. Serum creatine phosphokinase as prognostic indicator in the management of electrical burn

    International Nuclear Information System (INIS)

    Memon, A.R.; Memon, F.M.; Shaikh, B.F.

    2008-01-01

    To determine the mean difference of serum creatine phosphokinase according to the extent of tissue damage and prognosis of the patients suffering from electrical burn injuries. During the study period, 38 patients with electrical burn injuries were enrolled. Victims of electrical burns with evidence of myocardial injury were excluded. Following admission, serum creatine phosphokinase was measured serially on 10 consecutive occasions. The data was later analyzed statistically using SPSS-10.0. Of the 38 patients, the mean age of the victims was 28 years, with males dominating the study population (82%). A statistically significant association was found between the level of serum creatine phosphokinase and likelihood of death (p=0.000). It was also found that serial monitoring of this enzyme can be used as prognostic indicator in the management of electrical burns injury. The level of creatine phosphokinase increased with the degree of tissue injuries in patients with electrical burns. This prognostic value is of great importance in the local setup, where sophisticated investigations to detect extent of injuries are not available. (author)

  18. Predictors of Serum 25-Hydroxyvitamin D Concentrations among a Sample of Egyptian Schoolchildren

    Directory of Open Access Journals (Sweden)

    Mones M. Abu Shady

    2016-01-01

    Full Text Available Objective. To assess the level of 25-hydroxyvitamin D status among a sample of Egyptian schoolchildren and to evaluate predictors of deficiency and insufficiency. Subjects and Methods. A cross-sectional study comprising 200 prepubescent schoolchildren aged from 9 to 11 years was performed. A questionnaire including frequency of midday sun exposure, milk intake, physical activity, and level of maternal education was taken. Body mass index (BMI was calculated; serum 25-hydroxyvitamin D [25(OHD], serum calcium, phosphorus, and parathyroid hormone were measured. Results. Vitamin D deficiency [serum 25(OHD < 20 ng/mL] was detected in 11.5% of subjects while its insufficiency (serum 25(OHD is between 20 and 29.9 ng/mL was detected in 15%. Results revealed that obesity, low physical activity, low sun exposure, and low maternal education level are significant predictors of insufficiency, though female gender, low maternal education level, and low milk intake are significant predictors of deficiency. Lower serum phosphorus and higher serum parathyroid hormone were significantly associated with both deficiency and insufficiency (p<0.05. Conclusion. Vitamin D deficiency and insufficiency are common among schoolchildren in Egypt. Food fortification, vitamin D supplementation, and increasing maternal awareness about the importance of physical activity and exposure of their children to ultraviolet light may help to overcome this problem.

  19. Trans-Cutaneous Bilirubinometery versus Serum Bilirubin in Neonatal Jaundice.

    Science.gov (United States)

    Mahram, Manoochehr; Oveisi, Sonia; Jaberi, Najmeh

    2015-12-01

    Hyperbilirubinemia is a common problem in neonates and causes serious complications. Thus, serial measurements of bilirubin should be done. This assessment is done through two methods of laboratory measurement in serum sample and transcutaneous bilirubinometer. This descriptive study compared transcutaneous bilirubin assessment and laboratory serum bilirubin. Bilirubin level was assessed among 256 neonates admitted to the Qods Children's Hospital in Qazvin- Iran, because of neonatal indirect jaundice, through two methods of transcutaneous bilirubinometery from two sites of forehead and sternum and laboratory measurement of bilirubin in serum. The cases were non-hemolytic icteric term neonates weighing 2500 gram or more and had not received phototherapy or other treatments. Neonates with hemolytic forms of jaundice, sepsis and suspicious to metabolic disorders were excluded. Assessments by means of KJ-8000 transcutaneous bilirubinometer from two sites of forehead and sternum and through laboratory measurement of serum bilirubin were registered and analyzed. The results of the current study showed that there was a correlation of 0.82 between serum bilirubin and transcutaneous forehead bilirubin assessment and for the used device sensitivity of 0.844; specificity of 0.842, Youden Index of 0.709 and Shortest of 0.042 for a cut-off of 12.4 in bilirubin of participants. Furthermore, Likelihood Ratio positive and negative (LR) were 5.665 and 0.164, respectively and diagnostic Odds Ratio (LR+/LR-) was 34.56. Transcutaneous bilirubinometery can be considered as a reliable tool to assess bilirubin for the screening of neonatal jaundice in term neonates.

  20. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

    . This study aimed to test that theory. Method: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. Results: We found statistically significant chromium contamination from the steel needle with mean differences......  Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bias...... between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline significant...

  1. CRNL library serials list

    International Nuclear Information System (INIS)

    Alburger, T.P.

    1982-04-01

    A list of 1900 serial publications (periodicals, society transactions and proceedings, annuals and directories, indexes, newspapers, etc.) is presented with volumes and years held by the Main Library. This library is the largest in AECL as well as one of the largest scientific and technical libraries in North America, and functions as a Canadian resource for nuclear information. A main alphabetical list is followed by broad subject field lists representing research interests, and lists of abstract and index serials, general bibliographic serials, conference indexes, press releases, English translations, and original language journals

  2. Soluble CD44 concentration in the serum and peritoneal fluid samples of patients with different stages of endometriosis.

    Science.gov (United States)

    Mashayekhi, Farhad; Aryaee, Hadis; Mirzajani, Ebrahim; Yasin, Ashraf Ale; Fathi, Abdolsatar

    2015-09-01

    Endometriosis is a gynecological disease defined by the histological presence of endometrial glands and stroma outside the uterine cavity, most commonly implanted over visceral and peritoneal surface within the female pelvis. CD44 is a membrane protein expressed by human endometrial cells, and it has been shown to promote the adhesion of endometrial cells. The aim of this study was to determine the levels of soluble CD44 (sCD44) in the serum and peritoneal fluid (PF) samples of patients with different stages of endometriosis. 39 PF and serum samples from normal healthy and 130 samples from different stages of patients with endometriosis (33 cases of stage I, 38 stage II, 30 stage III and 29 stage IV) were included in this study. Total protein concentration (TPC) and the level of s-cMet in the serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay, respectively. No significant change in the TPC was seen in the serum of patients with endometriosis when compared to normal controls. Results obtained demonstrated that all serum and peritoneal fluid samples, presented sCD44 expression, whereas, starting from stages I to IV endometriosis, a significant increase of sCD44 expression was observed as compared to control group. The results of this study show that a high expression of sCD44 is correlated with advanced stages of endometriosis. It is also concluded that the detection of serum and/or peritoneal fluid sCD44 may be useful in classifying endometriosis.

  3. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  4. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  5. Effect of a Marathon Run on Serum Lipoproteins, Creatine Kinase, and Lactate Dehydrogenase in Recreational Runners

    Science.gov (United States)

    Kobayashi, Yoshio; Takeuchi, Toshiko; Hosoi, Teruo; Yoshizaki, Hidekiyo; Loeppky, Jack A.

    2005-01-01

    The objective of this study was to determine the effect of a marathon run on serum lipid and lipoprotein concentrations and serum muscle enzyme activities and follow their recovery after the run. These blood concentrations were measured before, immediately after, and serially after a marathon run in 15 male recreational runners. The triglyceride…

  6. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  7. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  8. Scientific and Technical Serials Holdings Optimization in an Inefficient Market: A LSU Serials Redesign Project Exercise.

    Science.gov (United States)

    Bensman, Stephen J.; Wilder, Stanley J.

    1998-01-01

    Analyzes the structure of the library market for scientific and technical (ST) serials. Describes an exercise aimed at a theoretical reconstruction of the ST-serials holdings of Louisiana State University (LSU) Libraries. Discusses the set definitions, measures, and algorithms necessary in the design of a computer program to appraise ST serials.…

  9. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

    Energy Technology Data Exchange (ETDEWEB)

    Coquelle, Nicolas [Université Grenoble Alpes, IBS, 38044 Grenoble (France); CNRS, IBS, 38044 Grenoble (France); CEA, IBS, 38044 Grenoble (France); Brewster, Aaron S. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Kapp, Ulrike; Shilova, Anastasya; Weinhausen, Britta [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Burghammer, Manfred, E-mail: burgham@esrf.fr [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Ghent University, Ghent B-9000 (Belgium); Colletier, Jacques-Philippe, E-mail: burgham@esrf.fr [Université Grenoble Alpes, IBS, 38044 Grenoble (France); CNRS, IBS, 38044 Grenoble (France); CEA, IBS, 38044 Grenoble (France)

    2015-05-01

    A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

  10. A comparative study of some physico-chemical properties of human serum albumin samples from different sources--I : Some physico-chemical properties of isoionic human serum albumin solutions

    NARCIS (Netherlands)

    Dröge, J.H.M.; Janssen, L.H.M.; Wilting, J.

    1982-01-01

    Human serum albumin samples from different sources were investigated. The fatty acid content of the albumin before and after deionization on a mixed bed ion-exchange column varied from sample to sample. When an albumin sample from one source was deionized under standard conditions the amount of

  11. Handbook of serial communications interfaces a comprehensive compendium of serial digital input/output (I/O) standards

    CERN Document Server

    Frenzel, Louis

    2015-01-01

    This book catalogs the most popular and commonly used serial-port interfaces and provides details on the specifications and the latest standards, enabling you to select an interface for a new design or verify that an interface is working correctly. Each chapter is based on a different interface and is written in an easy to follow, standard format. With this book you will learn: The most widely used serial interfacesHow to select the best serial interface for a specific application or designThe trade-offs between data rate and distance (length or range)The operation and benefits of serial

  12. DETECTION OF SERIAL SERUM P-185 LEVEL IN PATIENTS WITH MALIGNANCY USING ELISA

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhi-hui; WU Ping; LI Li; MIAO Yi-meng; LI Jun

    2006-01-01

    Objective: To investigate P-185 contents in serum of the normal person and cancer patients and it's the significance on prognosis of diseases. Methods: We used ELISA method to evaluate P-185 levels in 193 normal persons, 133 malignancies and 34 hepatocirrhosises were evaluated using ELISA method. Results: Normal person had lower expression of P-185. However, malignancy and hepatocirrhosis patients had a significantly higher expression level of P-185 than normal (P<0.05). Conclusion: ELISA method is an easy and reliable way to measure the level of P-185 in serum. Being a cancer marker, P-185 overexpression can be used for early diagnosis and prognosis of cancer patients.

  13. Quantitative profiling of serum samples using TMT protein labelling, fractionation and LC-MS/MS.

    Science.gov (United States)

    Sinclair, John; Timms, John F

    2011-08-01

    Blood-borne biomarkers are urgently required for the early detection, accurate diagnosis and prognosis of disease. Additionally, improved methods of profiling serum and plasma proteins for biomarker discovery efforts are needed. Herein, we report a quantitative method based on amino-group labelling of serum proteins (rather than peptides) with isobaric tandem mass tags (TMT) and incorporating immune-based depletion, gel-based and strong anion exchange separation of proteins prior to differential endoproteinase treatment and liquid chromatography tandem mass spectrometry. We report a generally higher level of quantitative coverage of the serum proteome compared to other peptide-based isobaric tagging approaches and show the potential of the method by applying it to a set of unique samples that pre-date the diagnosis of pancreatic cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    Science.gov (United States)

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  15. Clinical, radiological and molecular diagnosis correlation in serum samples from patients with osteoarticular tuberculosis

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2014-07-01

    Conclusions: Nested PCR in serum samples is a rapid, highly sensitive and specific modality for OTB detection. PCR should be performed in addition to clinical evaluation, imaging studies, acid-fast bacilli staining, culture and histopathology diagnosis, if possible.

  16. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  17. The effect of a non-denaturing detergent and a guanidinium-based inactivation agent on the viability of Ebola virus in mock clinical serum samples.

    Science.gov (United States)

    Burton, J E; Easterbrook, L; Pitman, J; Anderson, D; Roddy, S; Bailey, D; Vipond, R; Bruce, C B; Roberts, A D

    2017-12-01

    The 2014 Ebola outbreak in West Africa required the rapid testing of clinical material for the presence of potentially high titre Ebola virus (EBOV). Safe, fast and effective methods for the inactivation of such clinical samples are required so that rapid diagnostic tests including downstream analysis by RT-qPCR or nucleotide sequencing can be carried out. One of the most commonly used guanidinium - based denaturing agents, AVL (Qiagen) has been shown to fully inactivate EBOV once ethanol is added, however this is not compatible with the use of automated nucleic acid extraction systems. Additional inactivation agents need to be identified that can be used in automated systems. A candidate inactivation agent is Triton X-100, a non-denaturing detergent that is frequently used in clinical nucleic acid extraction procedures and has previously been used for inactivation of EBOV. In this study the effect of 0.1% and 1.0% Triton X-100 (final concentration 0.08% and 0.8% respectively) alone and in combination with AVL on the viability of EBOV (10 6 TCID 50 /ml) spiked into commercially available pooled negative human serum was tested. The presence of viable EBOV in the treated samples was assessed by carrying out three serial passages of the samples in Vero E6 cells (37°C, 5% CO 2 , 1 week for each passage). At the end of each passage the cells were observed for evidence of cytopathic effect and samples were taken for rRT-PCR analysis for the presence of EBOV RNA. Before cell culture cytotoxic components of AVL and Triton X-100 were removed from the samples using size exclusion spin column technology or a hydrophobic adsorbent resin. The results of this study showed that EBOV spiked into human serum was not fully inactivated when treated with either 0.1% (v/v) Triton X-100 for 10 mins or 1.0% (v/v) Triton X-100 for 20 mins (final concentrations 0.08% and 0.8% Triton X-100 respectively). AVL alone also did not consistently provide complete inactivation. Samples treated

  18. Comparisons among serum, egg albumin and yolk concentrations of corticosterone as biomarkers of basal and stimulated adrenocortical activity of laying hens.

    Science.gov (United States)

    Cook, N J; Renema, R; Wilkinson, C; Schaefer, A L

    2009-09-01

    1. Serial blood samples from individual birds were analysed for corticosterone concentrations under basal and stimulated conditions, and matched to eggs from the same birds for comparison to albumin and yolk concentrations of corticosterone. 2. Serum corticosterone exhibited increases in response to stimulation by ACTH and Handling stress. There were no significant increases in egg albumin or yolk concentrations of corticosterone following stimulation. 3. Several significant correlations were observed between the mean and area under the curve (AUC) measurements of serum corticosterone concentrations with albumin and yolk corticosterone concentrations in eggs laid from 1 to 2 d later. 4. The results demonstrated a relationship between endogenous concentrations of serum corticosterone that reflected daily adrenocortical output with albumin and yolk corticosterone concentrations in eggs laid the following day. 5. The results do not support the concept of albumin and yolk concentrations of corticosterone as biomarkers of acute adrenocortical responses to stimulation.

  19. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  20. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  1. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    Metabonomics offers a distinct advantage over other tests as it can be ... Metabolic profiling in heart disease has also been successfully ... resonances of the small metabolites showing fingerprints of serum metabolomic profile (Figure. 3).

  2. Ultratrace analysis of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in human serum and cerebrospinal fluid (CSF) samples

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K.; Watanabe, K.; Takemori, H. [Shimadzu Techno Research, Inc., Kyoto (Japan); Shoda, T. [Ehime Univ. Medical Research Center, Matsuyama (Japan); Kuroda, Y. [Tokyo Metropolitan Inst. for Neuroscience, Tokyo (Japan)

    2004-09-15

    In the present study, we established pretreatment and high sensitivity analytical method of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in serum and cerebrospinal fluid (CSF) of humans for the first time. Analyzing serum and CSF samples from humans found unique because PCBs behavior and metabolism could be discerned. Furthermore, so far studies reported concentrations of OH-PCBs in wildlife samples obtained by HRGC-LRMS or GC-ECD data. In this study, we established cleanup and analytical methods by high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) using 1 mL of sample. Mainly, total PCBs and OH-PCBs in the CSF were extracted by specialized developed method. Using this method, PCBs and OH-PCBs could be determined swiftly. Based on this method, major OH-PCB congeners were detected from human, serum, CSF, control serum and Rhesus monkey plasma. Present methodology developed based on the isotope dilution technique using OH-PCBs standard and thus we suggest the present methodology could apply for ultra trace analysis of OHPCBs as well as total PCBs in human samples.

  3. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  4. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    Science.gov (United States)

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from studies. We confirmed from the relationships between questionnaire results and the PFC concentrations in the serum samples, that food is one of the important contribution factors of human exposure to PFCs. However, there were no correlations between the PFC concentrations in the one day composite diet samples and the serum samples, because a one day composite diet sample is not necessarily representative of a person's long-term diet and because of the small number of samples taken. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Quantitation of 14C-oxaliplatin concentrations in human serum samples by using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kobayashi, Takeshi; Toyoguchi, Teiko; Kato, Kazuhiro; Tokanai, Fuyuki; Shiraishi, Tadashi

    2013-01-01

    The understanding of human pharmacokinetics is important for development of new drugs. Microdosing studies have been proposed as means of obtaining human pharmacokinetics information at early stages of drug development. Accelerator mass spectrometry (AMS) has high detection sensitivity and is expected to play an important role in microdose trials. In this study, we used the AMS microdosing facility at Yamagata University to measure the concentration of 14 C in 14 C-oxaliplatin-spiked serum samples. The calibration curve of 14 C concentration in serum was linear, and the correlation coefficient was 0.9994. The precision, accuracy, and stability values obtained (freeze and thaw cycles, and short- and long-term stability) satisfied the criteria. The mean background 14 C concentrations in samples of 6 healthy Japanese volunteers were 1.635dpm/mL in blood and 0.56dpm/mL in plasma. These results suggest the suitability of AMS-based quantitation for analyzing samples from microdosing studies. (author)

  6. Successfully Managed Acute Transverse Myelitis Related to Scrub Typhus and Serial Image Findings.

    Science.gov (United States)

    Yun, Jae Sung; Song, Ji Soo; Choi, Eun Jung; Hwang, Jeong-Hwan; Lee, Chang-Seop; Park, Eun Hae

    2017-03-01

    AbstractCentral nervous system involvement manifesting as meningitis or meningoencephalitis is a known complication of scrub typhus, but very few spinal cord lesions such as acute transverse myelitis (ATM) have been reported in association with this disease. Scrub typhus patients with a spinal lesion present with neurologic symptoms including dysuria, motor, and sensory weakness. Herein, we describe a rare case of ATM associated with scrub typhus. Clinical characteristics, cerebrospinal fluid cytology, Orientia tsutsugamushi serum antibody titer, and serial magnetic resonance imaging scans resulted in a diagnosis of ATM associated with scrub typhus.

  7. Potential prognostic significance of decreased serum levels of TRAIL after acute myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Paola Secchiero

    Full Text Available BACKGROUND: Since soluble TRAIL exhibits anti-inflammatory and anti-atherosclerotic activities both in vitro and in animal models, this study was designed to assess the relationship between the serum levels of TRAIL and clinical outcomes in patients with acute myocardial infarction (AMI. METHODOLOGY/PRINCIPAL FINDINGS: Levels of TRAIL were measured by ELISA in serial serum samples obtained from 60 patients admitted for AMI, both during hospitalization and in a follow-up of 12 months, as well as in 60 healthy control subjects. Serum levels of TRAIL were significantly decreased in patients with AMI at baseline (within 24 hours from admission, compared with healthy controls, and showed a significant inverse correlation with a series of negative prognostic markers, such as CK, CK-MB and BNP. TRAIL serum levels progressively increased at discharge, but normalized only at 6-12 months after AMI. Of note, low TRAIL levels at the patient discharge were associated with increased incidence of cardiac death and heart failure in the 12-month follow-up, even after adjustment for demographic and clinical risk parameters (hazard ratio [HR] of 0.93 [95% CI, 0.89 to 0.97]; p = 0.001. CONCLUSIONS/SIGNIFICANCE: Although the number of patients studied was limited, our findings indicate for the first time that circulating TRAIL might represent an important predictor of cardiovascular events, independent of conventional risk markers.

  8. Female serial killing: review and case report.

    Science.gov (United States)

    Frei, Andreas; Völlm, Birgit; Graf, Marc; Dittmann, Volker

    2006-01-01

    Single homicide committed by women is rare. Serial killing is very infrequent, and the perpetrators are usually white, intelligent males with sadistic tendencies. Serial killing by women has, however, also been described. To conduct a review of published literature on female serial killers and consider its usefulness in assessing a presenting case. A literature review was conducted, after searching EMBASE, MEDLINE and PsycINFO. The presenting clinical case is described in detail in the context of the literature findings. Results The literature search revealed few relevant publications. Attempts to categorize the phenomenon of female serial killing according to patterns of and motives for the homicides have been made by some authors. The most common motive identified was material gain or similar extrinsic gratification while the 'hedonistic' sadistic or sexual serial killer seems to be extremely rare in women. There is no consistent theory of serial killing by women, but psychopathic personality traits and abusive childhood experiences have consistently been observed. The authors' case did not fit the description of a 'typical' female serial killer. In such unusual circumstances as serial killing by a woman, detailed individual case formulation is required to make sense of the psychopathology in each case. Publication of cases in scientific journals should be encouraged to advance our understanding of this phenomenon. Copyright (c) 2006 John Wiley & Sons, Ltd.

  9. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  10. Neuromyelitis optica in a young child with positive serum autoantibody

    OpenAIRE

    Loma, Ingrid P.; Asato, Miya R.; Filipink, Robyn A.; Alper, Gulay

    2008-01-01

    Relapsing neuromyelitis optica is rare in children. The identification of highly specific serum autoantibody marker (neuromyelitis optica –immunoglobulin G) differentiates neuromyelitis optica from other demyelinating disorders particularly in clinically challenging cases. We present a child with multiple episodes of transverse myelitis and optic neuritis with positive neuromyelitis optica-immunoglobulin G titers consistent with a diagnosis of relapsing neuromyelitis optica. Serial titers of ...

  11. The eyeball killer: serial killings with postmortem globe enucleation.

    Science.gov (United States)

    Coyle, Julie; Ross, Karen F; Barnard, Jeffrey J; Peacock, Elizabeth; Linch, Charles A; Prahlow, Joseph A

    2015-05-01

    Although serial killings are relatively rare, they can be the cause of a great deal of anxiety while the killer remains at-large. Despite the fact that the motivations for serial killings are typically quite complex, the psychological analysis of a serial killer can provide valuable insight into how and why certain individuals become serial killers. Such knowledge may be instrumental in preventing future serial killings or in solving ongoing cases. In certain serial killings, the various incidents have a variety of similar features. Identification of similarities between separate homicidal incidents is necessary to recognize that a serial killer may be actively killing. In this report, the authors present a group of serial killings involving three prostitutes who were shot to death over a 3-month period. Scene and autopsy findings, including the unusual finding of postmortem enucleation of the eyes, led investigators to recognize the serial nature of the homicides. © 2015 American Academy of Forensic Sciences.

  12. Analytical validation of a new point-of-care assay for serum amyloid A in horses.

    Science.gov (United States)

    Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M

    2018-01-17

    Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the

  13. The relationship between serum ammonia level and neurologic complications in patients with acute glufosinate ammonium poisoning: A prospective observational study.

    Science.gov (United States)

    Cha, Y S; Kim, H; Lee, Y; Choi, E H; Kim, H I; Kim, O H; Cha, K-C; Lee, K H; Hwang, S O

    2018-06-01

    Glufosinate ammonium poisoning can cause neurological complications even after a symptom-free period. We prospectively investigated the predictors of neurologic complications in acute glufosinate ammonium poisoning and the change of serum ammonia level as a predictor of patient's presence and recovery of neurologic complication. This prospective observational study collected data from consecutive patients diagnosed with acute glufosinate ammonium poisoning between September 2014 and June 2016. Serum ammonia was serially measured. The patients were divided into two groups: the neurologic complication group and the nonneurologic complication group. We also defined 25 other insecticide- or herbicide-poisoned patients as controls. The neurologic complication group included 18 patients (72.0%). The latency period for neurologic complications was within 48-h postingestion. The peak ammonia level was statistically higher in the neurologic complication group than in the control group ( p glufosinate ammonium poisoning, serial serum ammonia level measurements are needed and a serum peak ammonia level greater than 90 μg/dL is a predictor of neurologic complications. Also, it is important to treat the hyperammonemia in acute glufosinate ammonium poisoning.

  14. “It’s Always the Same, and It’s Always Different” Mythologisation and the Serial Killer in Henry: Portrait of a Serial Killer.

    OpenAIRE

    Smyth, David A.

    2015-01-01

    Serial killers are important in American horror because of their ability to exist between ‘myth’ and ‘reality’. The serial killer is one of the most important American myths, but it is one firmly rooted in real life: unlike Paul Bunyan or Superman, serial killers do exist. This essay examines the relationship between the ‘myth’ and the ‘reality’ of serial killers, and the complex relationship between the American public and the serial killer, using Henry: Portrait of a Serial K...

  15. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Evaluation of nested polymerase chain reaction for the early detection of Leptospira spp. DNA in serum samples from patients with leptospirosis.

    Science.gov (United States)

    Blanco, Roberta Morozetti; Romero, Eliete Caló

    2014-04-01

    The aim of this study was to analyse the nested polymerase chain reaction (nested PCR) in human serum samples of patients with clinical manifestations of leptospirosis. The cases of leptospirosis were defined by the microagglutination test (MAT). The samples were collected in 2010. Of 1042 serum samples collected from 521 patients, 28 (5.4%) were considered positive cases of leptospirosis, and 493 (94.6%) were negative. Twenty-three confirmed cases had no MAT-detectable antibodies in the acute sample (mean of 5.6 days after onset). Nested PCR was positive in 22/23 (95.7%) patients during the acute phase of the disease, with negative results by MAT. Nested PCR was negative in all convalescent serum samples with positive results by MAT. All negative cases of leptospirosis were negative by nested PCR. The nested PCR is an alternative diagnostic tool for early detection of leptospires in sera during the first 7 days of the disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  18. Serial CT scannings in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Fukushima, Masashi; Sawada, Tohru; Kuriyama, Yoshihiro; Kinugawa, Hidekazu; Yamaguchi, Takenori

    1981-01-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemipare sis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis. (author)

  19. Enzymatically Modified Starch Ameliorates Postprandial Serum Triglycerides and Lipid Metabolome in Growing Pigs.

    Science.gov (United States)

    Metzler-Zebeli, Barbara U; Eberspächer, Eva; Grüll, Dietmar; Kowalczyk, Lidia; Molnar, Timea; Zebeli, Qendrim

    2015-01-01

    Developing host digestion-resistant starches to promote human health is of great research interest. Chemically modified starches (CMS) are widely used in processed foods and although the modification of the starch molecule allows specific reduction in digestibility, the metabolic effects of CMS have been less well described. This short-term study evaluated the impact of enzymatically modified starch (EMS) on fasting and postprandial profiles of blood glucose, insulin and lipids, and serum metabolome in growing pigs. Eight jugular-vein catheterized pigs (initial body weight, 37.4 kg; 4 months of age) were fed 2 diets containing 72% purified starch (EMS or waxy corn starch (control)) in a cross-over design for 7 days. On day 8, an 8-hour meal tolerance test (MTT) was performed with serial blood samplings. Besides biochemical analysis, serum was analysed for 201 metabolites through targeted mass spectrometry-based metabolomic approaches. Pigs fed the EMS diet showed increased (Pmetabolome profiling identified characteristic changes in glycerophospholipid, lysophospholipids, sphingomyelins and amino acid metabolome profiles with EMS diet compared to control diet. Results showed rapid adaptations of blood metabolites to dietary starch shifts within 7 days. In conclusion, EMS ingestion showed potential to attenuate postprandial raise in serum lipids and suggested constant alteration in the synthesis or breakdown of sphingolipids and phospholipids which might be a health benefit of EMS consumption. Because serum insulin was not lowered, more research is warranted to reveal possible underlying mechanisms behind the observed changes in the profile of serum lipid metabolome in response to EMS consumption.

  20. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  1. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  2. Correlation of Cadmium and Magnesium in the Blood and Serum Samples of Smokers and Non-Smokers Chronic Leukemia Patients.

    Science.gov (United States)

    Khan, Noman; Afridi, Hasan Imran; Kazi, Tasneem Gul; Arain, Muhammad Balal; Bilal, Muhammad; Akhtar, Asma; Khan, Mustafa

    2017-03-01

    It was studied that cancer-causing processes are related with the disproportions of essential and toxic elements in body tissues and fluid. The purpose of the current study was to evaluate the levels of magnesium (Mg) and cadmium (Cd) in serum and blood samples of smokers and nonsmokers who have chronic myeloid (CML) and lymphocytic (CLL) leukemia, age ranged 31-50 years. For comparative study, age-matched smokers and nonsmoker males were chosen as controls/referents. The levels of elements in patient were analyzed before any treatment by atomic absorption spectrophotometer, after microwave assisted acid digestion. The validation of the method was done by using certified reference materials of serum and blood samples. The resulted data indicated that the adult male smokers and nonsmokers have two- to fourfold higher levels of Cd in the blood and sera samples as compared to the referents (p blood and serum samples of both types of leukemia patients as related to referent values. The resulted data indicates significant negative correlation among Mg and Cd in leukemia patients and smoker referents. Further studies are needed to clarify the role of these elements in pathogenesis of chronic leukemia.

  3. Silicon Photonics for Signal Processing of Tbit/s Serial Data Signals

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Ji, Hua; Galili, Michael

    2012-01-01

    In this paper, we describe our recent work on signal processing of terabit per second optical serial data signals using pure silicon waveguides. We employ nonlinear optical signal processing in nanoengineered silicon waveguides to perform demultiplexing and optical waveform sampling of 1.28-Tbit/...

  4. Serial CT scans and Menkes' kinky hair disease

    International Nuclear Information System (INIS)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-01-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 μ g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died. (author)

  5. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  6. Serial interprocessor communications system

    International Nuclear Information System (INIS)

    Labiak, W.; Siemens, P.; Bailey, C.

    1980-01-01

    A serial communications system based on the EIA RS232-C standard with modem control lines has been developed. The DLV11-E interface is used for this purpose. All handshaking is done with the modem control lines. This allows totally independent full duplex communication. The message format consists of eight bit data with odd parity and a sixteen bit checksum on the whole message. All communications are fully interrupt driven. A program was written to load a program into a remote LSI-11 using the serial line without bootstrap ROM

  7. A Survey of Electronic Serials Managers Reveals Diversity in Practice

    Directory of Open Access Journals (Sweden)

    Laura Costello

    2014-09-01

    Full Text Available A Review of: Branscome, B. A. (2013. Management of electronic serials in academic libraries: The results of an online survey. Serials Review, 39(4, 216-226. http://dx.doi.org/10.1016/j.serrev.2013.10.004 Abstract Objective – To examine industry standards for the management of electronic serials and measure the adoption of electronic serials over print. Design – Survey questionnaire. Setting – Email lists aimed at academic librarians working in serials management. Subjects – 195 self-selected subscribers to serials email lists. Methods – The author created a 20 question survey that consisted primarily of closed-ended questions pertaining to the collection demographics, staff, budget, and tools of serials management groups in academic libraries. The survey was conducted via Survey Monkey and examined using the analytical features of the tool. Participants remained anonymous and the survey questions did not ask them to reveal identifiable information about their libraries. Main Results – Collection demographics questions revealed that 78% of surveyed librarians estimated that print-only collections represented 40% or fewer of their serials holdings. The author observed diversity in the factors that influence print to digital transitions in academic libraries. However 71.5% of participants indicated that publisher technology support like IP authentication was required before adopting digital subscriptions. A lack of standardization also marked serials workflows, department responsibilities, and department titles. The author did not find a correlation between serials budget and the enrollment size of the institution. Participants reported that they used tools from popular serials management vendors like Serials Solutions, Innovative Interfaces, EBSCO, and Ex Libris, but most indicated that they used more than one tool for serials management. Participants specified 52 unique serials management products used in their libraries. Conclusion

  8. Criminal psychological profiling of serial arson crimes.

    Science.gov (United States)

    Kocsis, Richard N; Cooksey, Ray W

    2002-12-01

    The practice of criminal psychological profiling is frequently cited as being applicable to serial arson crimes. Despite this claim, there does not appear to be any empirical research that examines serial arson offence behaviors in the context of profiling. This study seeks to develop an empirical model of serial arsonist behaviors that can be systematically associated with probable offender characteristics. Analysis has produced a model of offence behaviors that identify four discrete behavior patterns, all of which share a constellation of common nondiscriminatory behaviors. The inherent behavioral themes of each of these patterns are explored with discussion of their broader implications for our understanding of serial arson and directions for future research.

  9. CMOS serial link for fully duplexed data communication

    Science.gov (United States)

    Lee, Kyeongho; Kim, Sungjoon; Ahn, Gijung; Jeong, Deog-Kyoon

    1995-04-01

    This paper describes a CMOS serial link allowing fully duplexed 500 Mbaud serial data communication. The CMOS serial link is a robust and low-cost solution to high data rate requirements. A central charge pump PLL for generating multiphase clocks for oversampling is shared by several serial link channels. Fully duplexed serial data communication is realized in the bidirectional bridge by separating incoming data from the mixed signal on the cable end. The digital PLL accomplishes process-independent data recovery by using a low-ratio oversampling, a majority voting, and a parallel data recovery scheme. Mostly, digital approach could extend its bandwidth further with scaled CMOS technology. A single channel serial link and a charge pump PLL are integrated in a test chip using 1.2 micron CMOS process technology. The test chip confirms upto 500 Mbaud unidirectional mode operation and 320 Mbaud fully duplexed mode operation with pseudo random data patterns.

  10. The Productivity Advantage of Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Shaw, Kathryn L.; Sørensen, Anders

    Serial entrepreneurs, who open more than one business, are found to have higher sales and higher productivity than novice entrepreneurs, who open one business. Using panel data on entrepreneurs and their firms from Denmark for 2001-2013, the serial entrepreneur has 67% higher sales than the novice......, but also opens firms that are larger in terms of the initial capital and labor, and thus is 39% more productive. There are subsets of firms that perform especially well – serial entrepreneurs that hold a portfolio of overlapping ongoing firms perform the best, as do those that open as limited liability...

  11. The American Serialization of Lord Jim

    Directory of Open Access Journals (Sweden)

    Stephen Donovan

    2017-12-01

    Full Text Available This essay presents the discovery of the American serialization of Joseph Conrad’s Lord Jim in New York’s Evening Telegram in 1903. This ‘lost’ serialization, it argues, invites a new perspective on Conrad’s early career by foregrounding the role of newspaper serialization and syndication in establishing his literary standing. After surveying the principal differences in the respective reading experiences of the periodical versus the book, it concludes by proposing that the prominence of women among Conrad’s first audiences requires us to reassess the basis for his success in North America and elsewhere.

  12. Which serial killers commit suicide? An exploratory study.

    Science.gov (United States)

    Lester, David; White, John

    2012-11-30

    In a sample of 483 serial killers, 6.2% were documented to have committed suicide. Those who committed suicide were found to come from more dysfunctional homes characterized by more psychiatric disturbance in the parents. The sexual acts involved in the murders by the suicides seemed to be more deviant in some aspects, such as committing more bizarre sexual acts or more often taping the murder. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Slurry sampling in serum blood for mercury determination by CV-AFS

    International Nuclear Information System (INIS)

    Aranda, Pedro R.; Gil, Raul A.; Moyano, Susana; De Vito, Irma; Martinez, Luis D.

    2009-01-01

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 μg L -1 Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L -1 and the relative standard deviation was 3.9% at levels around of 0.4 μg L -1 Hg

  14. Serum phosphate is an early predictor of outcome in severe acetaminophen-induced hepatotoxicity

    DEFF Research Database (Denmark)

    Schmidt, Lars E; Dalhoff, Kim

    2002-01-01

    Hypophosphatemia is frequently observed in acetaminophen-induced hepatotoxicity and may be involved in the pathogenesis of hepatic failure. The aim of the study was to evaluate the prognostic value of serial measurements of serum phosphate in patients with severe acetaminophen poisoning. Prospect......Hypophosphatemia is frequently observed in acetaminophen-induced hepatotoxicity and may be involved in the pathogenesis of hepatic failure. The aim of the study was to evaluate the prognostic value of serial measurements of serum phosphate in patients with severe acetaminophen poisoning...... Hospital (KCH) criteria. Phosphate concentrations were significantly higher in nonsurvivors than in survivors at 48 to 72 hours after overdose (mean 2.65 +/- 1.18 mmol/L vs. 0.68 +/- 0.22 mmol/L, P L vs. 0.59 +/- 0.23 mmol/L, P ...). A threshold phosphate concentration of 1.2 mmol/L at 48 to 96 hours after overdose had sensitivity 89%, specificity 100%, accuracy 98%, positive predictive value 100%, and negative predictive value 98%. The phosphate criteria had higher sensitivity, accuracy, and positive and negative predictive values than...

  15. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of

  16. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  17. Dynamic of CSF and serum biomarkers in HIV-1 subtype C encephalitis with CNS genetic compartmentalization-case study.

    Science.gov (United States)

    de Almeida, Sergio M; Rotta, Indianara; Ribeiro, Clea E; Oliveira, Michelli F; Chaillon, Antoine; de Pereira, Ana Paula; Cunha, Ana Paula; Zonta, Marise; Bents, Joao França; Raboni, Sonia M; Smith, Davey; Letendre, Scott; Ellis, Ronald J

    2017-06-01

    Despite the effective suppression of viremia with antiretroviral therapy, HIV can still replicate in the central nervous system (CNS). This was a longitudinal study of the cerebrospinal fluid (CSF) and serum dynamics of several biomarkers related to inflammation, the blood-brain barrier, neuronal injury, and IgG intrathecal synthesis in serial samples of CSF and serum from a patient infected with HIV-1 subtype C with CNS compartmentalization.The phylogenetic analyses of plasma and CSF samples in an acute phase using next-generation sequencing and F-statistics analysis of C2-V3 haplotypes revealed distinct compartmentalized CSF viruses in paired CSF and peripheral blood mononuclear cell samples. The CSF biomarker analysis in this patient showed that symptomatic CSF escape is accompanied by CNS inflammation, high levels of cell and humoral immune biomarkers, CNS barrier dysfunction, and an increase in neuronal injury biomarkers with demyelization. Independent and isolated HIV replication can occur in the CNS, even in HIV-1 subtype C, leading to compartmentalization and development of quasispecies distinct from the peripheral plasma. These immunological aspects of the HIV CNS escape have not been described previously. To our knowledge, this is the first report of CNS HIV escape and compartmentalization in HIV-1 subtype C.

  18. Serial Position Functions in General Knowledge

    Science.gov (United States)

    Kelley, Matthew R.; Neath, Ian; Surprenant, Aimée M.

    2015-01-01

    Serial position functions with marked primacy and recency effects are ubiquitous in episodic memory tasks. The demonstrations reported here explored whether bow-shaped serial position functions would be observed when people ordered exemplars from various categories along a specified dimension. The categories and dimensions were: actors and age;…

  19. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... with mean differences between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline...

  20. Analysis of assembly serial number usage in domestic light-water reactors

    International Nuclear Information System (INIS)

    Reich, W.J.; Moore, R.S.

    1991-05-01

    Domestic light-water reactor (LWR) fuel assemblies are identified by a serial number that is placed on each assembly. These serial numbers are used as identifiers throughout the life of the fuel. The uniqueness of assembly serial numbers is important in determining their effectiveness as unambiguous identifiers. The purpose of this study is to determine what serial numbering schemes are used, the effectiveness of these schemes, and to quantify how many duplicate serial numbers occur on domestic LWR fuel assemblies. The serial numbering scheme adopted by the American National Standards Institute (ANSI) ensures uniqueness of assembly serial numbers. The latest numbering scheme adopted by General Electric (GE), was also found to be unique. Analysis of 70,971 fuel assembly serial numbers from permanently discharged fuel identified 11,948 serial number duplicates. Three duplicate serial numbers were found when analysis focused on duplication within the individual fuel inventory at each reactor site, but these were traced back to data entry errors and will be corrected by the Energy Information Administration (EIA). There were also three instances where the serial numbers used to identify assemblies used for hot cell studies differed from the serial numbers reported to the EIA. It is recommended that fuel fabricators and utilities adhere to the ANSI serial numbering scheme to ensure serial number uniqueness. In addition, organizations collecting serial number information, should request that all known serial numbers physically attached or associated with each assembly be reported and identified by the corresponding number scheme. 10 refs., 5 tabs

  1. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  2. Serial CT scannings in herpes simplex encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Fukushima, M.; Sawada, T.; Kuriyama, Y.; Kinugawa, H.; Yamaguchi, T. (National Cardivascular Center, Osaka (Japan))

    1981-10-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemiparesis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis.

  3. An initial validation of the Virtual Reality Paced Auditory Serial Addition Test in a college sample.

    Science.gov (United States)

    Parsons, Thomas D; Courtney, Christopher G

    2014-01-30

    Numerous studies have demonstrated that the Paced Auditory Serial Addition Test (PASAT) has utility for the detection of cognitive processing deficits. While the PASAT has demonstrated high levels of internal consistency and test-retest reliability, administration of the PASAT has been known to create undue anxiety and frustration in participants. As a result, degradation of performance may be found on the PASAT. The difficult nature of the PASAT may subsequently decrease the probability of their return for follow up testing. This study is a preliminary attempt at assessing the potential of a PASAT embedded in a virtual reality environment. The Virtual Reality PASAT (VR-PASAT) was compared with a paper-and-pencil version of the PASAT as well as other standardized neuropsychological measures. The two modalities of the PASAT were conducted with a sample of 50 healthy university students, between the ages of 19 and 34 years. Equivalent distributions were found for age, gender, education, and computer familiarity. Moderate relationships were found between VR-PASAT and other putative attentional processing measures. The VR-PASAT was unrelated to indices of learning, memory, or visuospatial processing. Comparison of the VR-PASAT with the traditional paper-and-pencil PASAT indicated that both versions require the examinee to sustain attention at an increasingly demanding, externally determined rate. Results offer preliminary support for the construct validity (in a college sample) of the VR-PASAT as an attentional processing measure and suggest that this task may provide some unique information not tapped by traditional attentional processing tasks. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Implementation of a Multichannel Serial Data Streaming Algorithm using the Xilinx Serial RapidIO Solution

    Science.gov (United States)

    Doxley, Charles A.

    2016-01-01

    In the current world of applications that use reconfigurable technology implemented on field programmable gate arrays (FPGAs), there is a need for flexible architectures that can grow as the systems evolve. A project has limited resources and a fixed set of requirements that development efforts are tasked to meet. Designers must develop robust solutions that practically meet the current customer demands and also have the ability to grow for future performance. This paper describes the development of a high speed serial data streaming algorithm that allows for transmission of multiple data channels over a single serial link. The technique has the ability to change to meet new applications developed for future design considerations. This approach uses the Xilinx Serial RapidIO LOGICORE Solution to implement a flexible infrastructure to meet the current project requirements with the ability to adapt future system designs.

  5. Dynamic change of serum protein S100b and its clinical significance in patients with traumatic brain injury

    Institute of Scientific and Technical Information of China (English)

    CHEN Da-qing; ZHU Lie-lie

    2005-01-01

    Objective: To analyze the dynamic change of serum protein S100b in patients with traumatic brain injury and its clinical value in assessing brain damage. Methods: According to Glasgow coma scale (GCS), 102 cases of traumatic brain injury were divided into mild brain injury group (GCS≥13, n=31, Group A), moderate brain injury group (8Serial S100b concentrations were analyzed by enzyme-linked immunosorbent assay (ELISA) in blood samples taken on admission, 12 h, 24 h, 48 h, 72 h and 7 days after traumatic brain injury. Results: The severe brain injury group showed significantly higher concentration of serum S100b, with earlier increase and longer duration, than the mild and moderate brain injury groups. The patients with higher S100b exhibited lower GCS scores and poor clinical prognosis. The increase in S100b could emerge before clinical image evidence indicated so. Conclusions: Serum S100b can be used as a sensitive index for assessment and prediction of traumatic brain injury severity and prognosis.

  6. SERIAL TELEVISI DEXTER SEBAGAI ANAKRONISME DALAM SASTRA POPULER

    Directory of Open Access Journals (Sweden)

    Ida Rochani Adi

    2014-06-01

    Full Text Available In the popular literature context, this study aims to investigate: (1 how the formulation of the characterization of Dexter in the television serial Dexter violates the tradition of literary characterization, and (2 how the formula of moral values is dramatized through Dexter, who is a sociopath, psychopath, serial killer, and person without moral. The research object was the television serial Dexter, which ranks five in popularity in the world. The data were collected by documenting 84 episodes of the serial having been broadcast since 2006. They were analyzed by means of content analysis and qualitative descriptive techniques. Based on the findings, the conclusions are as follows. First, there is a violation or anachronism of characterization through the main character in the serial. Second, the dramatized moral values still contain conventional values although they are in different forms.

  7. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  8. Determination of crenolanib in human serum and cerebrospinal fluid by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS).

    Science.gov (United States)

    Roberts, Michael S; Turner, David C; Owens, Thandranese S; Ramachandran, Abhijit; Wetmore, Cynthia; Throm, Stacy L; Stewart, Clinton F

    2013-06-15

    A LC-ESI-MS/MS method for the determination of crenolanib (CP-868,596) in human serum was developed and validated employing d4-CP-868,596 as an internal standard (ISTD). In addition to human serum, the method was also partially validated for crenolanib determination in human cerebrospinal fluid (CSF) samples. Sample aliquots (50μl of serum or CSF) were prepared for analysis using liquid-liquid extraction (LLE) with tert-butyl methyl ether. Chromatography was performed using a phenomenex Gemini C18 column (3μm, 100mm×4.6mm I.D.) in a column heater set at 50°C and an isocratic mobile phase (methanol/water/formic acid at a volume ratio of 25/25/0.15, v/v/v). The flow rate was 0.45mL/min, and the retention time for both analyte and ISTD was less than 3.5min. Samples were analyzed with an API-5500 LC-MS/MS system (ESI) in positive ionization mode coupled to a Shimadzu HPLC system. The ion transitions monitored were m/z 444.4→373.1 and m/z 448.2→374.2 for crenolanib and ISTD, respectively. The method was linear over the range of 5-1000ng/mL for serum and 0.5-1000ng/mL for CSF. For human serum, both intra-day and inter-day precision were <4%, while intra-day and inter-day accuracy were within 8% of nominal values. Recovery was greater than 50% for both the analyte and ISTD. For CSF samples, both intra-day and inter-day precision were <9% except at the lower limit of quantification (LLOQ) which was <17%. The intra-day and inter-day accuracy were within 11% of the nominal CSF concentrations. After validation, this method was successfully applied to the analysis of serial pharmacokinetic samples obtained from a child treated with oral crenolanib. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Delaware's first serial killer.

    Science.gov (United States)

    Inguito, G B; Sekula-Perlman, A; Lynch, M J; Callery, R T

    2000-11-01

    The violent murder of Shirley Ellis on November 29, 1987, marked the beginning of the strange and terrible tale of Steven Bryan Pennell's reign as the state of Delaware's first convicted serial killer. Three more bodies followed the first victim, and all had been brutally beaten and sadistically tortured. The body of a fifth woman has never been found. State and county police collaborated with the FBI to identify and hunt down their suspect, forming a task force of over 100 officers and spending about one million dollars. Through their knowledge and experience with other serial killers, the FBI was able to make an amazingly accurate psychological profile of Delaware's serial killer. After months of around-the-clock surveillance, Steven Pennell was arrested on November 29, 1988, one year to the day after the first victim was found. Pennell was found guilty in the deaths of the first two victims on November 29, 1989, and plead no contest to the murder of two others on October 30, 1991. Still maintaining his innocence, he asked for the death penalty so that he could spare his family further agony. Steven Pennell was executed by lethal injection on March 15, 1992.

  10. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  11. Serial CT scans and Menkes' kinky hair disease

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Eizo; Kameyama, Junji; Yoshimitsu, Hajime; Mori, Mikio; Tanaka, Mutsuo; Yoshimitsu, Kazunori.

    1988-02-01

    Menkes' kinky hair disease is a sex-linked recessive disorder of copper metabolism, characterized by progressive psychomotor deterioration, seizures, and peculiar hair structure. We examined serial CT scans of patients with this disease. A 2,210-g male infant was delivered after an uneventful gestation of 36 weeks. His one-minute Apgar score was 9. His uncle had died at 1 year of age. His first cousin was also diagnosed as having Menkes' kinky hair disease when our patient was 2 years old. Shortly after birth he had mild respiratory distress. At 5 days of age, he developed setting-sun signs. The first CT scan, at 10 days of age, revealed mild posterior fossa hemorrhages. At 3 months of age, myoclonic seizures began, and the CT scan revealed subdural effusion and mild brain atrophy. The seizures were controllable by using phenobarbital, valproic acid, and nitrazepam. He did not follow light or a fixate, but the fundi were normal. He was diffusely hypotonic. At 9 months of age, the seizures became uncontrollable. The CT scans at 15 and 31 months of age showed subdural hemorrhage and/or brain atrophy. At 15 months of age, the serum copper level was 42 ..mu.. g/dl, while the serum ceruloplasmin level was 3.2 mg/dl. He exhibited severe developmental failure. At 4 years of age, he died.

  12. Rapid-Sequence Serial Sexual Homicides.

    Science.gov (United States)

    Schlesinger, Louis B; Ramirez, Stephanie; Tusa, Brittany; Jarvis, John P; Erdberg, Philip

    2017-03-01

    Serial sexual murderers have been described as committing homicides in a methodical manner, taking substantial time between offenses to elude the authorities. The results of our study of the temporal patterns (i.e., the length of time between homicides) of a nonrandom national sample of 44 serial sexual murderers and their 201 victims indicate that this representation may not always be accurate. Although 25 offenders (56.8%) killed with longer than a 14-day period between homicides, a sizeable subgroup was identified: 19 offenders (43.2%) who committed homicides in rapid-sequence fashion, with fewer than 14 days between all or some of the murders. Six offenders (13.6%) killed all their victims in one rapid-sequence, spree-like episode, with homicides just days apart or sometimes two murders in the same day. Thirteen offenders (29.5%) killed in one or two rapid-sequence clusters (i.e., more than one murder within a 14-day period, as well as additional homicides with greater than 14 days between each). The purpose of our study was to describe this subgroup of rapid-sequence offenders who have not been identified until now. These findings argue for accelerated forensic assessments of dangerousness and public safety when a sexual murder is detected. Psychiatric disorders with rapidly occurring symptom patterns, or even atypical mania or mood dysregulation, may serve as exemplars for understanding this extraordinary group of offenders. © 2017 American Academy of Psychiatry and the Law.

  13. Classifying serial killers.

    Science.gov (United States)

    Promish, D I; Lester, D

    1999-11-08

    We attempted to match the appearance and demeanor of 27 serial killers to the postmortem 'signatures' found on their victims' bodies. Our results suggest that a link may exist between postmortem signatures and two complementary appearance-demeanor types.

  14. CAMAC serial highway interface for the LSI-11

    International Nuclear Information System (INIS)

    Lau, N.H.

    1980-01-01

    A CAMAC Serial Highway Interface has been designed for the Local Control and Instrumentation System of the Mirror Fusion Test Facility. There are over 50 distinguishable systems in the facility, each of which consists of the LSI-11 computer, fiber optic communication links, and the CAMAC system. The LSI-11 computer includes a 32k memory, serial modem interface and the CAMAC Serial Highway Interface

  15. Viscous hydrophilic injection matrices for serial crystallography

    Directory of Open Access Journals (Sweden)

    Gabriela Kovácsová

    2017-07-01

    Full Text Available Serial (femtosecond crystallography at synchrotron and X-ray free-electron laser (XFEL sources distributes the absorbed radiation dose over all crystals used for data collection and therefore allows measurement of radiation damage prone systems, including the use of microcrystals for room-temperature measurements. Serial crystallography relies on fast and efficient exchange of crystals upon X-ray exposure, which can be achieved using a variety of methods, including various injection techniques. The latter vary significantly in their flow rates – gas dynamic virtual nozzle based injectors provide very thin fast-flowing jets, whereas high-viscosity extrusion injectors produce much thicker streams with flow rates two to three orders of magnitude lower. High-viscosity extrusion results in much lower sample consumption, as its sample delivery speed is commensurate both with typical XFEL repetition rates and with data acquisition rates at synchrotron sources. An obvious viscous injection medium is lipidic cubic phase (LCP as it is used for in meso membrane protein crystallization. However, LCP has limited compatibility with many crystallization conditions. While a few other viscous media have been described in the literature, there is an ongoing need to identify additional injection media for crystal embedding. Critical attributes are reliable injection properties and a broad chemical compatibility to accommodate samples as heterogeneous and sensitive as protein crystals. Here, the use of two novel hydrogels as viscous injection matrices is described, namely sodium carboxymethyl cellulose and the thermo-reversible block polymer Pluronic F-127. Both are compatible with various crystallization conditions and yield acceptable X-ray background. The stability and velocity of the extruded stream were also analysed and the dependence of the stream velocity on the flow rate was measured. In contrast with previously characterized injection media, both new

  16. Notorious Cases of Serial Killers

    Directory of Open Access Journals (Sweden)

    Iosub Elena-Cătălina

    2014-05-01

    Full Text Available The reconstruction of a death scene provides an overall picture of the crime and will indicate the murder as an event or one of a series of events and also the criminal. But when the criminal is declared a serial killer, many questions are raised up. How could a person kill some else without a reason or why people react in such a disorganized way and become so brutal or what made them act like that and so many questions with also so many answers. This project explains the psychology of a murderer, his own way of thinking and acting by presuming that we may accurately discover what is in their minds when they kill. It is about a very complex issue regarding murder investigations, biological factors and psychological profile of a serial killer. Dealing with this problem we will at last reach to the question that could solve finally the puzzle: ―Are serial murderers distorted reflections of society's own values?

  17. Modus operandi of female serial killers.

    Science.gov (United States)

    Wilson, W; Hilton, T

    1998-04-01

    The modus operandi of female serial killers was examined from a chronology of 58 cases in America and 47 cases in 17 other countries, compiled over 25-year intervals. Female serial killers in other countries accounted for a disproportionately greater number of victims, but those in America managed a longer killing career when associated with a low profile modus operandi.

  18. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  19. Estimating Population Parameters using the Structured Serial Coalescent with Bayesian MCMC Inference when some Demes are Hidden

    Directory of Open Access Journals (Sweden)

    Allen Rodrigo

    2006-01-01

    Full Text Available Using the structured serial coalescent with Bayesian MCMC and serial samples, we estimate population size when some demes are not sampled or are hidden, ie ghost demes. It is found that even with the presence of a ghost deme, accurate inference was possible if the parameters are estimated with the true model. However with an incorrect model, estimates were biased and can be positively misleading. We extend these results to the case where there are sequences from the ghost at the last time sample. This case can arise in HIV patients, when some tissue samples and viral sequences only become available after death. When some sequences from the ghost deme are available at the last sampling time, estimation bias is reduced and accurate estimation of parameters associated with the ghost deme is possible despite sampling bias. Migration rates for this case are also shown to be good estimates when migration values are low.

  20. Deconvolution of serum cortisol levels by using compressed sensing.

    Directory of Open Access Journals (Sweden)

    Rose T Faghih

    Full Text Available The pulsatile release of cortisol from the adrenal glands is controlled by a hierarchical system that involves corticotropin releasing hormone (CRH from the hypothalamus, adrenocorticotropin hormone (ACTH from the pituitary, and cortisol from the adrenal glands. Determining the number, timing, and amplitude of the cortisol secretory events and recovering the infusion and clearance rates from serial measurements of serum cortisol levels is a challenging problem. Despite many years of work on this problem, a complete satisfactory solution has been elusive. We formulate this question as a non-convex optimization problem, and solve it using a coordinate descent algorithm that has a principled combination of (i compressed sensing for recovering the amplitude and timing of the secretory events, and (ii generalized cross validation for choosing the regularization parameter. Using only the observed serum cortisol levels, we model cortisol secretion from the adrenal glands using a second-order linear differential equation with pulsatile inputs that represent cortisol pulses released in response to pulses of ACTH. Using our algorithm and the assumption that the number of pulses is between 15 to 22 pulses over 24 hours, we successfully deconvolve both simulated datasets and actual 24-hr serum cortisol datasets sampled every 10 minutes from 10 healthy women. Assuming a one-minute resolution for the secretory events, we obtain physiologically plausible timings and amplitudes of each cortisol secretory event with R (2 above 0.92. Identification of the amplitude and timing of pulsatile hormone release allows (i quantifying of normal and abnormal secretion patterns towards the goal of understanding pathological neuroendocrine states, and (ii potentially designing optimal approaches for treating hormonal disorders.

  1. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  2. Site-specific RNase A activity was dramatically reduced in serum from multiple types of cancer patients.

    Directory of Open Access Journals (Sweden)

    Weiyan Huang

    Full Text Available Potent RNase activities were found in the serum of mammals but the physiological function of the RNases was never well illustrated, largely due to the caveats in methods of RNase activity measurement. None of the existing methods can distinguish between RNases with different target specificities. A systematic study was recently carried out in our lab to investigate the site-specificity of serum RNases on double-stranded RNA substrates, and found that serum RNases cleave double-stranded RNAs predominantly at 5'-U/A-3' and 5'-C/A-3' dinucleotide sites, in a manner closely resembling RNase A. Based on this finding, a FRET assay was developed in the current study to measure this site-specific serum RNase activity in human samples using a double stranded RNA substrate. We demonstrated that the method has a dynamic range of 10(-5 mg/ml- 10(-1 mg/ml using serial dilution of RNase A. The sera of 303 cancer patients were subjected to comparison with 128 healthy controls, and it was found that serum RNase activities visualized with this site-specific double stranded probe were found to be significantly reduced in patients with gastric cancer, liver cancer, pancreatic cancer, esophageal cancer, ovary cancer, cervical cancer, bladder cancer, kidney cancer and lung cancer, while only minor changes were found in breast and colon cancer patients. This is the first report using double stranded RNA as probe to quantify site-specific activities of RNase A in a serum. The results illustrated that RNase A might be further evaluated to determine if it can serve as a new class of biomarkers for certain cancer types.

  3. Site-Specific RNase A Activity Was Dramatically Reduced in Serum from Multiple Types of Cancer Patients

    Science.gov (United States)

    Huang, Weiyan; Zhao, Mei; Wei, Na; Wang, Xiaoxia; Cao, Huqing; Du, Quan; Liang, Zicai

    2014-01-01

    Potent RNase activities were found in the serum of mammals but the physiological function of the RNases was never well illustrated, largely due to the caveats in methods of RNase activity measurement. None of the existing methods can distinguish between RNases with different target specificities. A systematic study was recently carried out in our lab to investigate the site-specificity of serum RNases on double-stranded RNA substrates, and found that serum RNases cleave double-stranded RNAs predominantly at 5′-U/A-3′ and 5′-C/A-3′ dinucleotide sites, in a manner closely resembling RNase A. Based on this finding, a FRET assay was developed in the current study to measure this site-specific serum RNase activity in human samples using a double stranded RNA substrate. We demonstrated that the method has a dynamic range of 10−5 mg/ml- 10−1 mg/ml using serial dilution of RNase A. The sera of 303 cancer patients were subjected to comparison with 128 healthy controls, and it was found that serum RNase activities visualized with this site-specific double stranded probe were found to be significantly reduced in patients with gastric cancer, liver cancer, pancreatic cancer, esophageal cancer, ovary cancer, cervical cancer, bladder cancer, kidney cancer and lung cancer, while only minor changes were found in breast and colon cancer patients. This is the first report using double stranded RNA as probe to quantify site-specific activities of RNase A in a serum. The results illustrated that RNase A might be further evaluated to determine if it can serve as a new class of biomarkers for certain cancer types. PMID:24805924

  4. Monocyte chemoattractant protein-1 and interleukin-8 levels in urine and serum of patents with hemolytic uremic syndrome.

    Science.gov (United States)

    van Setten, P A; van Hinsbergh, V W; van den Heuvel, L P; Preyers, F; Dijkman, H B; Assmann, K J; van der Velden, T J; Monnens, L A

    1998-06-01

    The epidemic form of the hemolytic uremic syndrome (HUS) in children is hallmarked by endothelial cell damage, most predominantly displayed by the glomerular capillaries. The influx of mononuclear (MO) and polymorphonuclear cells (PMNs) into the glomeruli may be an important event in the initiation, prolongation, and progression of glomerular endothelial cell damage in HUS patients. The molecular mechanisms for the recruitment of these leukocytes into the kidney are unclear, but monocyte chemoattractant protein-1 (MCP-1) and IL-8 are suggested to be prime candidates. In this study, we analyzed the presence of both chemokines in 24-h urinary (n = 15) and serum (n = 14) samples of HUS children by specific ELISAs. Furthermore, kidney biopsies of three different HUS children were examined for MO and PMN cell infiltration by histochemical techniques and electron microscopy. Whereas the chemokines MCP-1 and IL-8 were present in only very limited amounts in urine of 17 normal control subjects, serial samples of HUS patients demonstrated significantly elevated levels of both chemokines. HUS children with anuria showed higher initial and maximum chemokine levels than their counterparts without anuria. A strong positive correlation was observed between urinary MCP-1 and IL-8 levels. Whereas initial serum IL-8 levels were significantly increased in HUS children, serum MCP-1 levels were only slightly elevated compared with serum MCP-1 in control children. No correlation was found between urinary and serum chemokine concentrations. Histologic and EM studies of HUS biopsy specimens clearly showed the presence of MOs and to a lesser extent of PMNs in the glomeruli. The present data suggest an important local role for MOs and PMNs in the process of glomerular endothelial-cell damage. The chemokines MCP-1 and IL-8 may possibly be implicated in the pathogenesis of HUS through the recruitment and activation of MOs and PMNs, respectively.

  5. cDNA Microarray Analysis of Serially Sampled Cervical Cancer Specimens From Patients Treated With Thermochemoradiotherapy

    International Nuclear Information System (INIS)

    Borkamo, Erling Dahl; Schem, Baard-Christian; Fluge, Oystein; Bruland, Ove; Dahl, Olav; Mella, Olav

    2009-01-01

    Purpose: To elucidate changes in gene expression after treatment with regional thermochemoradiotherapy in locally advanced squamous cell cervical cancer. Methods and Materials: Tru-Cut biopsy specimens were serially collected from 16 patients. Microarray gene expression levels before and 24 h after the first and second trimodality treatment sessions were compared. Pathway and network analyses were conducted by use of Ingenuity Pathways Analysis (IPA; Ingenuity Systems, Redwood City, CA). Single gene expressions were analyzed by quantitative real-time reverse transcription-polymerase chain reaction. Results: We detected 53 annotated genes that were differentially expressed after trimodality treatment. Central in the three top networks detected by IPA were interferon alfa, interferon beta, and interferon gamma receptor; nuclear factor κB; and tumor necrosis factor, respectively. These genes encode proteins that are important in regulation cell signaling, proliferation, gene expression, and immune stimulation. Biological processes over-represented among the 53 genes were fibrosis, tumorigenesis, and immune response. Conclusions: Microarrays showed minor changes in gene expression after thermochemoradiotherapy in locally advanced cervical cancer. We detected 53 differentially expressed genes, mainly involved in fibrosis, tumorigenesis, and immune response. A limitation with the use of serial biopsy specimens was low quality of ribonucleic acid from tumors that respond to highly effective therapy. Another 'key limitation' is timing of the post-treatment biopsy, because 24 h may be too late to adequately assess the impact of hyperthermia on gene expression.

  6. Glyco-centric lectin magnetic bead array (LeMBA − proteomics dataset of human serum samples from healthy, Barrett׳s esophagus and esophageal adenocarcinoma individuals

    Directory of Open Access Journals (Sweden)

    Alok K. Shah

    2016-06-01

    Full Text Available This data article describes serum glycoprotein biomarker discovery and qualification datasets generated using lectin magnetic bead array (LeMBA – mass spectrometry techniques, “Serum glycoprotein biomarker discovery and qualification pipeline reveals novel diagnostic biomarker candidates for esophageal adenocarcinoma” [1]. Serum samples collected from healthy, metaplastic Barrett׳s esophagus (BE and esophageal adenocarcinoma (EAC individuals were profiled for glycoprotein subsets via differential lectin binding. The biomarker discovery proteomics dataset consisting of 20 individual lectin pull-downs for 29 serum samples with a spiked-in internal standard chicken ovalbumin protein has been deposited in the PRIDE partner repository of the ProteomeXchange Consortium with the data set identifier PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD002442. Annotated MS/MS spectra for the peptide identifications can be viewed using MS-Viewer (〈http://prospector2.ucsf.edu/prospector/cgi-bin/msform.cgi?form=msviewer〉 using search key “jn7qafftux”. The qualification dataset contained 6-lectin pulldown-coupled multiple reaction monitoring-mass spectrometry (MRM-MS data for 41 protein candidates, from 60 serum samples. This dataset is available as a supplemental files with the original publication [1].

  7. Serum magnesium, phosphorus, and calcium levels and subclinical calcific aortic valve disease: A population-based study.

    Science.gov (United States)

    Hisamatsu, Takashi; Miura, Katsuyuki; Fujiyoshi, Akira; Kadota, Aya; Miyagawa, Naoko; Satoh, Atsushi; Zaid, Maryam; Yamamoto, Takashi; Horie, Minoru; Ueshima, Hirotsugu

    2018-06-01

    Calcific aortic valve disease (CAVD) is the most common valve disease. Although micronutrients are known to contribute to cardiovascular disease, the relationship with CAVD remains poorly evaluated. We examined the association of serum levels of magnesium, phosphorus, and calcium with prevalence, incidence, and progression of aortic valve calcification (AVC). We conducted a prospective study in a population-based sample of Japanese men aged 40-79 years without known cardiovascular disease and chronic kidney disease at baseline, and quantified AVC from serial computed tomographic images with the Agatston method. Of 938 participants at baseline (mean age, 63.7 ± 9.9 years), AVC prevalence was observed in 173 (18.4%). Of 596 participants without baseline AVC at follow-up (median duration, 5.1 years), AVC incidence was observed in 138 (23.2%). After adjustment for demographics, behaviors and cardiovascular risk factors, relative risks (95% confidence intervals) in the highest versus lowest categories of serum magnesium, phosphorus, and calcium were 0.62 (0.44-0.86), 1.45 (1.02-2.04), and 1.43 (0.95-2.15), respectively, for AVC prevalence and 0.62 (0.42-0.92), 1.93 (1.28-2.91), and 1.09 (0.77-1.55), respectively, for AVC incidence. Their linear trends of serum magnesium and phosphorus were also all statistically significant. Of 131 participants with baseline AVC, there was no association of any serum micronutrients with AVC progression. Serum magnesium was inversely associated, while serum phosphorus was positively associated with AVC prevalence and incidence, suggesting that these serum micronutrients may be potential candidates for risk prediction or prevention of CAVD, and warranting further studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. SERIAL TELEVISI DEXTER SEBAGAI ANAKRONISME DALAM SASTRA POPULER

    OpenAIRE

    Ida Rochani Adi

    2014-01-01

    In the popular literature context, this study aims to investigate: (1) how the formulation of the characterization of Dexter in the television serial Dexter violates the tradition of literary characterization, and (2) how the formula of moral values is dramatized through Dexter, who is a sociopath, psychopath, serial killer, and person without moral. The research object was the television serial Dexter, which ranks five in popularity in the world. The data were collected by documenting 84 epi...

  9. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  10. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    Science.gov (United States)

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  11. Clinical significance of dynamic measurements of serum and urinary TNF-α contents in patients receiving kidney transplantation

    International Nuclear Information System (INIS)

    Wu Cuihua; Xu Jun; Zhang Daojie

    2004-01-01

    Objective: To investigate the clinical significance of dynamic measurements of serum and urinary TNF-α contents in patients following kidney transplantation. Methods: Serum and urinary TNF-α contents were measured with RIA in 45 patients receiving kidney transplantation (both before and 2 day after operation) and 45 controls. In the group of 33 patients without rejection, serial dynamic measurements of serum and urinary TNF-α content were repeatedly performed on d7, d14, d21 and d28 postoperatively. Results: Serum TNF-α levels in all the patients groups were significantly higher than those in the controls (P 0.05). Urinary TNF-α levels dropped even faster and approached control values by d7. Conclusion: Continuous monitoring of post-operative serum and urinary TNF-α contents serves as an important indicator of the function of the transplanted kidney

  12. The Serial Murderer's Motivations: An Interdisciplinary Review.

    Science.gov (United States)

    DeHart, Dana D.; Mahoney, John M.

    1994-01-01

    Defines serial killer as individual who murders two or more victims over an extended period of time, ranging from days to years, with the crimes often being sexually motivated. Reviews existing motivational theories of serial murder and proposes additional explications from range of disciplines. Presents suggestions for future research and…

  13. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  14. From animal cruelty to serial murder: applying the graduation hypothesis.

    Science.gov (United States)

    Wright, Jeremy; Hensley, Christopher

    2003-02-01

    Although serial murder has been recorded for centuries, limited academic attention has been given to this important topic. Scholars have attempted to examine the causality and motivations behind the rare phenomenon of serial murder. However, scant research exists which delves into the childhood characteristics of serial murderers. Using social learning theory, some of these studies present supporting evidence for a link between childhood animal cruelty and adult aggression toward humans. Based on five case studies of serial murderers, we contribute to the existing literature by exploring the possible link between childhood cruelty toward animals and serial murder with the application of the graduation hypothesis.

  15. Types I and III procollagen extension peptides in serum respond to fracture in humans

    DEFF Research Database (Denmark)

    Joerring, S; Jensen, L T; Andersen, G R

    1992-01-01

    Markers of types I and III collagen turnover were measured in serial blood samples in 16 patients with a Colles' fracture. The collagen markers were the carboxy-terminal extension peptide of type I procollagen (PICP) and the amino-terminal extension peptide of type III procollagen (PIIINP......). Significant increases were found of PIIINP within 1 week and of PICP within 2 weeks. This sequential appearance of PIIINP and PICP was found to be in agreement with the appearance of types III and I collagen during early fracture healing as demonstrated in previous animal experimental studies. PICP had...... levelled off after 9 months, whereas PIIINP remained elevated. Osteocalcin, a serum marker of osteoblast activity, increased within 1 week and levelled off after 9 months. Correlations between the change in osteocalcin and those in PICP and PIIINP, respectively, were weak. These new biochemical markers may...

  16. Serial Austen. Mashingups with Zombies

    Directory of Open Access Journals (Sweden)

    Eleonora Federici

    2017-01-01

    Full Text Available Jane Austen sells. She sells in all possible ways, her novels have been adapted for the cinema and the stage, they have been rewritten as comics and graphic novels. Jane austen is a cultural icon. The interest in her life is so strong that many biographies have been written in order to recover new facts and details. The places where she has lived and the places depicted in her novels have become tourist sites for literary pilgrims. Austen is a cross-over phenomenon, with regency costume balls recreated in her name and an endless proliferation of her works in all media. My essay will investigate Jane Austen and Seth Grahame-Smith’s Pride and Prejudice and Zombies (2009, a mash-up novel which has become a real cultural phenomenon of the last decade and will demonstrate how it can be considered a serial narrative. If as Henry Jenkins asserts, seriality implies the unfolding of a story over time through a process of “chunking” (that is creating meaningful parts of the same story and of “dispersal” (that is breaking the story into more parts and in more genres and media, mash-ups seems to do this.  Austen’s story remains as a “story hook” which pushes the reader to come back to different products for a continuation of the same story. So, if on the one hand, seriality occurs within the same text, the story-telling of Austen’s stories across genres and media is part of a seriality process.

  17. Sensing the Opaque : Seriality and the Aesthetics of Televisual Form

    NARCIS (Netherlands)

    Dasgupta, S.; Kelleter, F.

    2017-01-01

    Recent work on TV seriality focuses on the deference of meaning through narrative extension. Contemporary seriality, it has been argued, exploits this expanding textuality to construct complicated narratives that tip the pleasures of seriality toward detecting the meaning of the plot's

  18. Injection Methods and Instrumentation for Serial X-ray Free Electron Laser Experiments

    Science.gov (United States)

    James, Daniel

    Scientists have used X-rays to study biological molecules for nearly a century. Now with the X-ray free electron laser (XFEL), new methods have been developed to advance structural biology. These new methods include serial femtosecond crystallography, single particle imaging, solution scattering, and time resolved techniques. The XFEL is characterized by high intensity pulses, which are only about 50 femtoseconds in duration. The intensity allows for scattering from microscopic particles, while the short pulses offer a way to outrun radiation damage. XFELs are powerful enough to obliterate most samples in a single pulse. While this allows for a "diffract and destroy" methodology, it also requires instrumentation that can position microscopic particles into the X-ray beam (which may also be microscopic), continuously renew the sample after each pulse, and maintain sample viability during data collection. Typically these experiments have used liquid microjets to continuously renew sample. The high flow rate associated with liquid microjets requires large amounts of sample, most of which runs to waste between pulses. An injector designed to stream a viscous gel-like material called lipidic cubic phase (LCP) was developed to address this problem. LCP, commonly used as a growth medium for membrane protein crystals, lends itself to low flow rate jetting and so reduces the amount of sample wasted significantly. This work discusses sample delivery and injection for XFEL experiments. It reviews the liquid microjet method extensively, and presents the LCP injector as a novel device for serial crystallography, including detailed protocols for the LCP injector and anti-settler operation.

  19. Serial private infrastructures

    NARCIS (Netherlands)

    van den Berg, V.A.C.

    2013-01-01

    This paper investigates private supply of two congestible infrastructures that are serial, where the consumer has to use both in order to consume. Four market structures are analysed: a monopoly and 3 duopolies that differ in how firms interact. It is well known that private supply leads too high

  20. Anti-Taenia solium metacestode IgG antibodies in serum samples from inhabitants of a central-western region of Brazil

    Directory of Open Access Journals (Sweden)

    Oliveira Heliana B. de

    2006-01-01

    Full Text Available A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB. Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51. The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5% and 47-52 kDa (80%. The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001. In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

  1. Serial murder: An unusual stereotype.

    Science.gov (United States)

    Sane, Mandar R; Mugadlimath, Anand B; Farooqui, Jamebaseer M; Janagond, Anand B; Mishra, Pradeep K

    2017-12-01

    Serial murders attract attention from the media, mental health experts, academia, and the general public. We present a case of serial murders that took place in a limited area and which caused public anxiety and anguish in central India. All the victims were homeless beggars, who were bludgeoned to death (crush injury). Individual murders were initially investigated by different police stations; fortunately, since they sent all the bodies to a common autopsy centre, a forensic pathologist was able to link all the cases, the first person to do so. This emphasises the need for sharing information among police stations and autopsy centres.

  2. Child serial murder-psychodynamics: closely watched shadows.

    Science.gov (United States)

    Turco, R

    2001-01-01

    There is a malignant transformation in object relations resulting in an identification with an omnipotent and cruel object resulting in an identity transformation. If the tension, desperation, and dissociation increase, serial murder becomes spree murder. The presence of pathological narcissism and psychopathic tendencies are of diagnostic significance in understanding the murderer's personality functioning and motivation to kill. Meloy (1988) considered the degree of sadism and aggression combined with narcissistic qualities to reflect the "malignancy" of the psychopathic disturbance where gratification (of aggression) occurs in the service of narcissistic functioning--that is, cruelty toward others in the form of a triumphant victory over a rejecting object. Meloy also believes that dissociation is ubiquitious in the psychopath. The initial murder of the serial murderer may reflect a "new identity." The pathological object-relations of narcissism and the malignant narcissism are important diagnostic indicators in the personality functioning of serial killers and the occurrence of these phenomena is a significant factor in the formation of the personalities of serial killers, their inner motivations, and their pattern of commission.

  3. IMPLEMENTATION OF SERIAL AND PARALLEL BUBBLE SORT ON FPGA

    Directory of Open Access Journals (Sweden)

    Dwi Marhaendro Jati Purnomo

    2016-06-01

    Full Text Available Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort required smaller memory as well as utility compared to parallel bubble sort. Meanwhile, parallel bubble sort performed faster than serial bubble sort

  4. A high speed serializer ASIC for ATLAS Liquid Argon calorimeter upgrade

    CERN Document Server

    Liu, T; The ATLAS collaboration

    2011-01-01

    The current front-end electronics of the ATLAS Liquid Argon calorimeters need to be upgraded to sustain the higher radiation levels and data rates expected at the upgraded LHC machine (HL-LHC), which will have 5 times more luminosity than the LHC in its ultimate configuration. This upgrade calls for an optical link system of 100 Gbps per front-end board (FEB). A high speed, low power, radiation tolerant serializer is the critical component in this system. In this paper, we present the design and test results of a single channel 16:1 serializer and the design of a double-channel 16:1 serializer. Both designs are based on a commercial 0.25 μm silicon-on-sapphire CMOS technology. The single channel serializer consists of a serializing unit, a PLL clock generator and a line driver implemented in current mode logic (CML). The serializing unit multiplexes 16 bit parallel LVDS data into 1-bit width serial CMOS data. The serializing unit is composed of a cascade of 2:1 multiplexing circuits based on static D-flip-fl...

  5. The use of enzyme-linked immunosorbent assay for detection of Mycoplasma hominis antibodies in infertile women serum samples

    DEFF Research Database (Denmark)

    Baczynska, Agata; Friis Svenstrup, Helle; Fedder, Jens

    2005-01-01

    BACKGROUND: Besides Chlamydiae trachomatis and Mycoplasma genitalium, Mycoplasma hominis may also cause infertility due to damage of the Fallopian tubes. Therefore serum samples from infertile women were analyzed for antibodies to M. hominis. METHODS: Sera from 304 infertile women were investigat...

  6. A novel technique of serial biopsy in mouse brain tumour models.

    Directory of Open Access Journals (Sweden)

    Sasha Rogers

    Full Text Available Biopsy is often used to investigate brain tumour-specific abnormalities so that treatments can be appropriately tailored. Dacomitinib (PF-00299804 is a tyrosine kinase inhibitor (TKI, which is predicted to only be effective in cancers where the targets of this drug (EGFR, ERBB2, ERBB4 are abnormally active. Here we describe a method by which serial biopsy can be used to validate response to dacomitinib treatment in vivo using a mouse glioblastoma model. In order to determine the feasibility of conducting serial brain biopsies in mouse models with minimal morbidity, and if successful, investigate whether this can facilitate evaluation of chemotherapeutic response, an orthotopic model of glioblastoma was used. Immunodeficient mice received cortical implants of the human glioblastoma cell line, U87MG, modified to express the constitutively-active EGFR mutant, EGFRvIII, GFP and luciferase. Tumour growth was monitored using bioluminescence imaging. Upon attainment of a moderate tumour size, free-hand biopsy was performed on a subgroup of animals. Animal monitoring using a neurological severity score (NSS showed that all mice survived the procedure with minimal perioperative morbidity and recovered to similar levels as controls over a period of five days. The technique was used to evaluate dacomitinib-mediated inhibition of EGFRvIII two hours after drug administration. We show that serial tissue samples can be obtained, that the samples retain histological features of the tumour, and are of sufficient quality to determine response to treatment. This approach represents a significant advance in murine brain surgery that may be applicable to other brain tumour models. Importantly, the methodology has the potential to accelerate the preclinical in vivo drug screening process.

  7. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. [The serial murder: a few theoretical perspectives].

    Science.gov (United States)

    Leistedt, S; Linkowski, P

    2011-01-01

    Despite numbers of publications and effort to try to establish the definition, the classification, the epidemiology, the clinical aspects and the psychopathology of serial killers, a universal consensus seems to say the least. Crime, though reduced in some countries, appears to impact more and more consistent worldwide, generating controversial ideas and a multitude of possible explanations. The serial killer usually presents as a caucasian man, aged between 20 and 40 years, often embedded socially and in his family, but with serious psychiatric, personal and especially family history. Usually acting alone, the serial killer plans a crime well in advance, but sometimes within the scope of impulsivity for a minority, the victim not being previously selected. In the latter case, an actual mental illness like psychosis is found. It is clear from numerous psychopathological studies conducted so far that most serial killers are defined as psychopathic sexual sadists, whose childhood was difficult, if not flouted, punctuated by physical and psychological violence situations. In addition, pervasive fantasies combined with thoughts of death, sex and violence are as much in common with the original acts of which they are the instigators. Beyond a relentless media that is constantly watering the public with stories and pictures depicting them as such, serial killers remain an enigma. We can therefore attempt to answer the various questions raised by this phenomenon, the way these people operate and how we can curb the rise, thanks to the neurobiological and neurophysiological approaches that science offers us.

  9. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  10. Agarose gel electrophoresis of cerebrospinal fluid proteins of dogs after sample concentration using a membrane microconcentrator technique.

    Science.gov (United States)

    Gama, Fernanda Gomes Velasque; Santana, Aureo Evangelista; Filho, Eugênio de Campos; Nogueira, Cláudia Aparecida da Silva

    2007-03-01

    Cerebrospinal fluid (CSF) is produced in the cerebral ventricles through ultrafiltration of plasma and active transport mechanisms. Evaluation of proteins in CSF may provide important information about the production of immunoglobulins within the central nervous system as well as possible disturbances in the blood-brain barrier. The objective of this study was to measure the concentration and fractions of protein in CSF samples using a membrane microconcentrator technique followed by electrophoresis, and to compare the protein fractions obtained with those in serum. CSF samples from 3 healthy dogs and 3 dogs with canine distemper virus infection were concentrated using a membrane microconcentrator having a 0.5 to 30,000 d nominal molecular weight limit (Ultrafree, Millipore, Billerica, MA, USA). Protein concentration was determined before and after concentration. Agarose gel electrophoresis was done on concentrated CSF samples, serum, and serial dilutions of one of the CSF samples. Electrophoretic bands were clearly identified in densitometer tracings in CSF samples with protein concentrations as low as 1.3 g/dL. The higher CSF protein concentration in dogs with distemper was mainly the result of increased albumin concentration. The microconcentrating method used in this study enables characterization of the main protein fractions in CSF by routine electrophoresis and may be useful for interpreting the underlying cause of changes in CSF protein concentrations.

  11. Microcontroller-based system for estimate of calcium in serum samples.

    Science.gov (United States)

    Neelamegam, Periyaswmy; Jamaludeen, Abdul Sheriff; Ragendran, Annamalai; Murugrananthan, Krishanamoorthy

    2010-01-01

    In this study, a microcontroller-based control unit was designed and constructed for the estimation of serum calcium in blood samples. The proposed optoelectronic instrument used a red light emitting diode (LED) as a light source and photodiode as a sensor. The performance of the system was compared with that of a commercial instrument in measuring calcium ion. The quantitative analysis of calcium in a catalyst using arsenazo III as colorimetric reagent was used to test the device. The calibration curve for calcium binding with arsenazo III was drawn to check the range of linearity, which was between 0.1 to 4.5 mM L⁻¹. The limit of detection (LOD) is 0.05 mM L⁻¹. Absorbance changes over the pH range of 2-12 were determined to optimize the assay, with maximum absorption at pH 9.0. Interferences in absorbance from monovalent (K+ and Na+) and divalent (Mg²+) cations were also studied. The results show that the system works successfully.

  12. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  13. Increased serum concentrations of soluble ST2 predict mortality after burn injury.

    Science.gov (United States)

    Hacker, Stefan; Dieplinger, Benjamin; Werba, Gregor; Nickl, Stefanie; Roth, Georg A; Krenn, Claus G; Mueller, Thomas; Ankersmit, Hendrik J; Haider, Thomas

    2018-06-27

    Large burn injuries induce a systemic response in affected patients. Soluble ST2 (sST2) acts as a decoy receptor for interleukin-33 (IL-33) and has immunosuppressive effects. sST2 has been described previously as a prognostic serum marker. Our aim was to evaluate serum concentrations of sST2 and IL-33 after thermal injury and elucidate whether sST2 is associated with mortality in these patients. We included 32 burn patients (total body surface area [TBSA] >10%) admitted to our burn intensive care unit and compared them to eight healthy probands. Serum concentrations of sST2 and IL-33 were measured serially using an enzyme-linked immunosorbent assay (ELISA) technique. The mean TBSA was 32.5%±19.6%. Six patients (18.8%) died during the hospital stay. Serum analyses showed significantly increased concentrations of sST2 and reduced concentrations of IL-33 in burn patients compared to healthy controls. In our study cohort, higher serum concentrations of sST2 were a strong independent predictor of mortality. Burn injuries cause an increment of sST2 serum concentrations with a concomitant reduction of IL-33. Higher concentrations of sST2 are associated with increased in-hospital mortality in burn patients.

  14. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  15. How Do We Write about Performance in Serial Television?

    Directory of Open Access Journals (Sweden)

    Elliott Logan

    2015-05-01

    Full Text Available Television studies has produced few sustained analyses of performance in serial television. Yet film studies scholarship has shown how attending to the integration of performances with other aspects of film style is crucial to the interpretation and appreciation of expression and meaning in filmed narrative fictions. However, as a particle form of filmed serial narrative, series television raises a number of questions about performance that will not necessarily be satisfyingly addressed by the direct adoption and application of approaches to writing about performance that have been honed in regard to film. How, then, do we write about performance in television serials in ways that recognise and accommodate the form’s relationship to film, while at the same time appropriately acknowledging and responding to long-form television’s serial status? To examine the difficulties and opportunities of approaching performance in serial television this way, the article conducts close readings of various pieces of television studies writing on performance, by scholars such as Jason Mittell, Sue Turnbull, George Toles, and Steven Peacock. Their work brings into view film and television’s points of common relation, and the distinctive challenges, achievements, and rewards of appreciating the best television serials, and the performances in them.

  16. Kadar Asam Urat Serum sebagai Biomarker Preeklamsi

    Directory of Open Access Journals (Sweden)

    Neli Sumanti

    2013-06-01

    Full Text Available Preeclampsia remains a health problem that becomes one of the causes of maternal deaths besides bleeding and infection. The etiology and pathogenesis of preeclampsia are unclear. Increased serum uric acid levels is seen simultaneously with the increase of blood pressure and occurred before the onset of proteinuria. Therefore, the uric acid can be used as a biomarker. The aim of this study was to analyze the serum uric acid levels between normal and preeclampsia pregnancies. The study was conducted in Dr.Hasan Sadikin Hospital Bandung between March and May 2011, using cross sectional study design. Subjects were 45 inpartu normal pregnant women as control and 44 in partu pregnant women with preeclampsia accordance with inclusion and exclusion criteria. Levels of uric acid in normal pregnancy are 3,43 ±0.14 mg/dL. In this study uric acid levels resulting in cut-off levels of 4,8 mg/dL with a sensitivity value of 93%, and specificity 80%. Conclusions: uric acid levels in at term preeclampsia are higher compared with normal pregnancies. Increased levels of uric acid can be considered as one of biomarkers of preeclampsia, hence the serum uric acid levels used as serial examinations in pregnant women during antenatal care.

  17. Serial crystallography captures enzyme catalysis in copper nitrite reductase at atomic resolution from one crystal

    Directory of Open Access Journals (Sweden)

    Sam Horrell

    2016-07-01

    Full Text Available Relating individual protein crystal structures to an enzyme mechanism remains a major and challenging goal for structural biology. Serial crystallography using multiple crystals has recently been reported in both synchrotron-radiation and X-ray free-electron laser experiments. In this work, serial crystallography was used to obtain multiple structures serially from one crystal (MSOX to study in crystallo enzyme catalysis. Rapid, shutterless X-ray detector technology on a synchrotron MX beamline was exploited to perform low-dose serial crystallography on a single copper nitrite reductase crystal, which survived long enough for 45 consecutive 100 K X-ray structures to be collected at 1.07–1.62 Å resolution, all sampled from the same crystal volume. This serial crystallography approach revealed the gradual conversion of the substrate bound at the catalytic type 2 Cu centre from nitrite to nitric oxide, following reduction of the type 1 Cu electron-transfer centre by X-ray-generated solvated electrons. Significant, well defined structural rearrangements in the active site are evident in the series as the enzyme moves through its catalytic cycle, namely nitrite reduction, which is a vital step in the global denitrification process. It is proposed that such a serial crystallography approach is widely applicable for studying any redox or electron-driven enzyme reactions from a single protein crystal. It can provide a `catalytic reaction movie' highlighting the structural changes that occur during enzyme catalysis. The anticipated developments in the automation of data analysis and modelling are likely to allow seamless and near-real-time analysis of such data on-site at some of the powerful synchrotron crystallographic beamlines.

  18. Determination of motive of serial invaders as a stage of serial murders investigation

    Directory of Open Access Journals (Sweden)

    Davydov A.B.

    2017-04-01

    Full Text Available the article discusses the existing classification of motives of serial murderers. The author provides the classification, which is based on the technique of extreme meanings offered by D.A. Leontyev.

  19. Playing at Serial Acquisitions

    NARCIS (Netherlands)

    J.T.J. Smit (Han); T. Moraitis (Thras)

    2010-01-01

    textabstractBehavioral biases can result in suboptimal acquisition decisions-with the potential for errors exacerbated in consolidating industries, where consolidators design serial acquisition strategies and fight escalating takeover battles for platform companies that may determine their future

  20. PORNOGRAFI DALAM SERIAL ANIME ANAK (ANALISIS SEMIOTIKA DALAM SERIAL CRAYON SHIN CHAN

    Directory of Open Access Journals (Sweden)

    - Sangidun

    2017-01-01

    Full Text Available Crayon Shin Chan, a Japanese two-dimension animation series broadcast in one of private Indonesian TVs, is categorized into child’s program since it is broadcast at child’s prime time, Sunday 08.30 a.m. In spite of its broadcast time, this series consist of symbols directed not for children, such as some acts that are not appropriate to be done by children, especially in Indonesia. Moreover, adult symbols of sex are also found in the program. For this reason it will be interesting to analyze it using semiotic analysis. Semiotics is the study of symbol and its meaning which its principle concept is that both signifier and signified consist of symbols and are related to denotation and connotation.   Crayon Shin Chan merupakan serial animasi dua dimensi yang tayang di salah satu stasiun televisi swasta di Indonesia. Ini merupakan produk animasi 2 dimensi yang diimpor dari Jepang. Di Indonesia, serial ini masuk dalam kategori acara anak. Hal ini dapat dilihat dari jam penayangannya yang merupakan waktu prime time bagi anak, yakni pada hari minggu pukul 08.30. Akan tetapi, pada serial ini banyak simbol-simbol yang mengarah pada tayangan yang bukan untuk anak-anak, yakni adeganadegan yang tidak pantas dilakukan oleh anak khususnya di Indonesia. Serta adanya pula simbol-simbol yang mengarah pada tayangan berbau dewasa. Tentu akan menarik jika tayangan ini diteliti menggunakan analisis semiotika. Semiotika sendiri merupakan kajian ilmu mengenai tanda dan makna. Yang pada prinsipnya, konsep penting seperti penanda (signifier dan petanda (signified sama-sama terdiri dari tanda dan terkait dengan denotasi dan konotasi.

  1. Stochastic modeling of a serial killer.

    Science.gov (United States)

    Simkin, M V; Roychowdhury, V P

    2014-08-21

    We analyze the time pattern of the activity of a serial killer, who during 12 years had murdered 53 people. The plot of the cumulative number of murders as a function of time is of "Devil's staircase" type. The distribution of the intervals between murders (step length) follows a power law with the exponent of 1.4. We propose a model according to which the serial killer commits murders when neuronal excitation in his brain exceeds certain threshold. We model this neural activity as a branching process, which in turn is approximated by a random walk. As the distribution of the random walk return times is a power law with the exponent 1.5, the distribution of the inter-murder intervals is thus explained. We illustrate analytical results by numerical simulation. Time pattern activity data from two other serial killers further substantiate our analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. An Investigation of Selective College and University Libraries' Serial Arrangement.

    Science.gov (United States)

    Kesler, Elizabeth Gates; Teborek, Gay

    Data from a survey on serials arrangement procedures and policies at academic libraries was used by the University of Rhode Island (URI) Library in changing current serials policies. Ten libraries, four of which have similar serial holdings and user populations to URI, responded to a questionnaire. Information was obtained on classification versus…

  3. A reappraisal of serial isotope bone scans in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    O' Donoghue, J M; Rogers, E; Grimes, H; McCarthy, P; Corcoran, M; Bredin, H; Given, H F [University College Hospital, Galway (Ireland)

    1993-08-01

    The authors have evaluated prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) as alternatives to conventional serial bone scanning in 129 patients with newly diagnosed prostate cancer over a period of 3 years. Although serum PSA did not reflect local tumour burden at presentation, it was significantly elevated in those with stage D disease (p < 0.01). 45 patients presented de novo with metastatic bone deposits and a further 18 patients developed metastases during the study. The sensitivity of PSA in detecting secondary deposits at presentation for levels in excess of 100 [mu]g/l was 93.75%, the positive predictive value 95.7% and the negative predictive value for levels less than 5 [mu]g/l was 90.6%. During the follow-up period sensitivity was 94.4%, the positive predictive value 100%, the negative predictive value 100%, with a median lead time of 3 months in predicting metastases in the 18 patients with progressive disease. (author).

  4. Serials cataloging at the turn of the century

    CERN Document Server

    Williams, James W

    2014-01-01

    An overview of the research topics and trends that have appeared over the last five years, Serials Cataloging at the Turn of the Century doesn't just tell you that there has been a lot of change--that the information environment is something of a chameleon, always beguiling and slipping out of grasp. Instead, it gives you the plain facts on the specific challenges serials catalogers have been facing and how they're meeting adversity head-on, ready to gain the advantage in the rumble with proliferating information and formats.Comprehensive, resource-packed, and easy-to-digest, Serials Catalogin

  5. Retrospective analysis of dengue specific IgM reactive serum samples

    Directory of Open Access Journals (Sweden)

    Nemai Bhattacharya

    2013-04-01

    Full Text Available Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1 antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: This reconstructed study revealed that of those 91 dengue cases, 70.3% (64 and 29.7% (27 were suffering from secondary and primary dengue respectively, showing that number of secondary dengue cases were much more than that of primary dengue cases with a possibility of emergence of DHF. A small proportion of cases 18.7% (17 were reactive for NS1. The duration of fever in NS1 antigen positive cases varied between 5 and 7 days. Of 17 NS1 reactive cases, 10 (10.9% and 7 (7.7% were suffering from secondary and primary dengue respectively. Conclusions: Early detection of primary and secondary dengue cases would be facilitated by utilizing all three parameters (NS1 antigen, anti-dengue IgM and IgG helping to evaluate, monitor and treat a dengue case effectively.

  6. Prevalence of parvovirus B19 and parvovirus V9 DNA and antibodies in paired bone marrow and serum samples from healthy individuals.

    Science.gov (United States)

    Heegaard, Erik D; Petersen, Bodil Laub; Heilmann, Carsten J; Hornsleth, Allan

    2002-03-01

    Parvovirus B19 (hereafter referred to as B19) exhibits a marked tropism to human bone marrow (BM), and infection may lead to erythema infectiosum, arthropathy, hydrops fetalis, and various hematologic disorders. Recently, a distinct parvovirus isolate termed V9 with an unknown clinical spectrum was discovered. In contrast to the many studies of B19 serology and viremia, valid information on the frequency of B19 or V9 DNA in the BM of healthy individuals is limited. To develop a reference value, paired BM and serum samples from healthy subjects were tested for the presence of B19 and V9 DNA and specific antibodies. Immunoglobulin M (IgM) was not found in any of the serum samples. The prevalence of IgG showed a gradual and steady increase from 37% in children aged 1 to 5 years to 87% in people aged >50 years. When 190 well-characterized subjects were examined, B19 DNA was detected in the BM of 4 individuals (2.1%; 95% confidence interval, 0.58 to 5.3%) while none of the paired serum samples showed evidence of circulating viral DNA. V9 DNA was not found in any of the BM or serum samples. The finding of B19 DNA probably indicated a primary infection in one 7-year-old individual and reinfection or reactivation of persistent infection in the remaining three persons, aged 47 to 58 years. Serving as a benchmark for future studies, these findings are useful when interpreting epidemiologic data, performing BM transplantation, or considering clinical implications of parvovirus infection.

  7. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  8. Fast Grasp Contact Computation for a Serial Robot

    Science.gov (United States)

    Shi, Jianying (Inventor); Hargrave, Brian (Inventor); Diftler, Myron A. (Inventor)

    2015-01-01

    A system includes a controller and a serial robot having links that are interconnected by a joint, wherein the robot can grasp a three-dimensional (3D) object in response to a commanded grasp pose. The controller receives input information, including the commanded grasp pose, a first set of information describing the kinematics of the robot, and a second set of information describing the position of the object to be grasped. The controller also calculates, in a two-dimensional (2D) plane, a set of contact points between the serial robot and a surface of the 3D object needed for the serial robot to achieve the commanded grasp pose. A required joint angle is then calculated in the 2D plane between the pair of links using the set of contact points. A control action is then executed with respect to the motion of the serial robot using the required joint angle.

  9. Representation of the serial killer on the Italian Internet.

    Science.gov (United States)

    Villano, P; Bastianoni, P; Melotti, G

    2001-10-01

    The representation of serial killers was examined from the analysis of 317 Web pages in the Italian language to study how the psychological profiles of serial killers are described on the Italian Internet. The correspondence analysis of the content of these Web pages shows that in Italy the serial killer is associated with words such as "monster" and "horror," which suggest and imply psychological perversion and aberrant acts. These traits are peculiar for the Italian scenario.

  10. The cortisol awakening response is associated with performance of a serial sequence reaction time task.

    Science.gov (United States)

    Hodyl, Nicolette A; Schneider, Luke; Vallence, Ann-Maree; Clow, Angela; Ridding, Michael C; Pitcher, Julia B

    2016-02-01

    There is emerging evidence of a relationship between the cortisol awakening response (CAR) and the neural mechanisms underlying learning and memory. The aim of this study was to determine whether the CAR is associated with acquisition, retention and overnight consolidation or improvement of a serial sequence reaction time task. Salivary samples were collected at 0, 15, 30 and 45 min after awakening in 39 healthy adults on 2 consecutive days. The serial sequence reaction time task was repeated each afternoon. Participants completed the perceived stress scale and provided salivary samples prior to testing for cortisol assessment. While the magnitude of the CAR (Z score) was not associated with either baseline performance or the timed improvement during task acquisition of the serial sequence task, a positive correlation was observed with reaction times during the stable performance phase on day 1 (r=0.373, p=0.019). Residuals derived from the relationship between baseline and stable phase reaction times on day 1 were used as a surrogate for the degree of learning: these residuals were also correlated with the CAR mean increase on day 1 (r=0.357, p=0.048). Task performance on day 2 was not associated with the CAR obtained on this same day. No association was observed between the perceived stress score, cortisol at testing or task performance. These data indicate that a smaller CAR in healthy adults is associated with a greater degree of learning and faster performance of a serial sequence reaction time task. These results support recognition of the CAR as an important factor contributing to cognitive performance throughout the day. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Effects of Serial Rehearsal Training on Memory Search

    Science.gov (United States)

    McCauley, Charley; And Others

    1976-01-01

    Half the subjects were trained to use a serial rehearsal strategy during target set storage and half were given no strategy training. The results indicate that the rate of memory search is IQ-related, and that serial rehearsal training facilitates memory search when rehearsal is covert. (Author/BW)

  12. Highlights in radiation measuring technique's - Serial Micro Channel SMC 2100

    International Nuclear Information System (INIS)

    Kandler, M.; Hoffmann, Ch.

    2002-01-01

    The Serial Micro Channel SMC 2100 offers an ''intelligent stand alone'' electronics for the radiation measuring technique's. First it is designed of being connected to a serial interface RS232 of a PC. With a RS485 serial interface on a PC, a network structure can be generated. It has all functional modules which are necessary for the measurement of detector signals. Hence it is possible to directly connect any detector for radiation measurement to a PC, laptop, or notebook. All variations can be operated without PC support too. It has a modular structure and consists of two blocks, the functional modules and the basic modules. The Serial Micro Channel SMC 2100 may be directly coupled to a detector, which therefore makes the realisation of an ''intelligent radiation detector'' with serial link RS232 or RS485. (orig.)

  13. Examining the relationship between free recall and immediate serial recall: the serial nature of recall and the effect of test expectancy.

    Science.gov (United States)

    Bhatarah, Parveen; Ward, Geoff; Tan, Lydia

    2008-01-01

    In two experiments, we examined the relationship between free recall and immediate serial recall (ISR), using a within-subjects (Experiment 1) and a between-subjects (Experiment 2) design. In both experiments, participants read aloud lists of eight words and were precued or postcued to respond using free recall or ISR. The serial position curves were U-shaped for free recall and showed extended primacy effects with little or no recency for ISR, and there was little or no difference between recall for the precued and the postcued conditions. Critically, analyses of the output order showed that although the participants started their recall from different list positions in the two tasks, the degree to which subsequent recall was serial in a forward order was strikingly similar. We argue that recalling in a serial forward order is a general characteristic of memory and that performance on ISR and free recall is underpinned by common memory mechanisms.

  14. Multistage parallel-serial time averaging filters

    International Nuclear Information System (INIS)

    Theodosiou, G.E.

    1980-01-01

    Here, a new time averaging circuit design, the 'parallel filter' is presented, which can reduce the time jitter, introduced in time measurements using counters of large dimensions. This parallel filter could be considered as a single stage unit circuit which can be repeated an arbitrary number of times in series, thus providing a parallel-serial filter type as a result. The main advantages of such a filter over a serial one are much less electronic gate jitter and time delay for the same amount of total time uncertainty reduction. (orig.)

  15. Converting serial networks to Ethernet communications

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Elroy [Freewave Technologies, Inc., Boulder, CO (United States). Latin America

    2008-07-01

    Many oil and gas producers and pipeline companies find themselves in an awkward position. They have invested millions of dollars in legacy serial communications systems and in most cases, millions more in older SCADA remote terminal units and electronic flow meters. There is a desire throughout most of the industry to convert these systems to Ethernet. This presentation will explore how Ethernet protocol offers advantages over the older serial communications in terms of peer to peer communication, faster polling cycles, and the ability to poll multiple devices at the same time. (author)

  16. Implementation of Serial and Parallel Bubble Sort on Fpga

    OpenAIRE

    Purnomo, Dwi Marhaendro Jati; Arinaldi, Ahmad; Priyantini, Dwi Teguh; Wibisono, Ari; Febrian, Andreas

    2016-01-01

    Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort r...

  17. Investigations on the presence of antibodies against equine herpesvirus-1 in blood serum of foals, prior to and after colostrum intake

    Directory of Open Access Journals (Sweden)

    Lauš Saša

    2015-01-01

    Full Text Available The titer of specific antibodies against equine herpesvirus-1 in blood serum was tested in two groups of mares and their foals. The first group consisted of 12 mares, Standardbred and Serbian Trotter breed, who were vaccinated against equine herpesvirus-1 and 4 in the 5th, 7th and 9th month of pregnancy. On the contrary, 12 mares from the second group, of Lipizzaner breed, were not vaccinated. The mares’ blood samples for antibodies titer investigation were taken 30, 15 and 7 days before the expected partus, then immediately after the partus, while their foals’ blood samples were taken immediately after foaling, then just before colostrum intake, and finally 1, 2, 3 and 7 days later. The titer of antibodies against equine herpesvirus-1 was tested by the method of virus - neutralization, on microtiter plates with constant dose of the virus and serial double dilutions of the serum. In unvaccinated mares, titer of antibodies against equine herpesvirus-1 was either low or not present, but on the contrary, in the vaccinated ones the antibodies titer ranged from 1:32 to 1:256. In the foals originating from both vaccinated and unvaccinated there were not found specific antibodies in the serum before colostrum intake. After the colostrum intake, the values of specific antibodies against equine herpesvirus-1 significantly increased in the foals originating from the vaccinated mares, and ranged from 1:8 to 1:32.

  18. Serial forced displacement in American cities, 1916-2010.

    Science.gov (United States)

    Fullilove, Mindy Thompson; Wallace, Rodrick

    2011-06-01

    Serial forced displacement has been defined as the repetitive, coercive upheaval of groups. In this essay, we examine the history of serial forced displacement in American cities due to federal, state, and local government policies. We propose that serial forced displacement sets up a dynamic process that includes an increase in interpersonal and structural violence, an inability to react in a timely fashion to patterns of threat or opportunity, and a cycle of fragmentation as a result of the first two. We present the history of the policies as they affected one urban neighborhood, Pittsburgh's Hill District. We conclude by examining ways in which this problematic process might be addressed.

  19. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  20. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  1. Challenges of microtome‐based serial block‐face scanning electron microscopy in neuroscience

    Science.gov (United States)

    WANNER, A. A.; KIRSCHMANN, M. A.

    2015-01-01

    Summary Serial block‐face scanning electron microscopy (SBEM) is becoming increasingly popular for a wide range of applications in many disciplines from biology to material sciences. This review focuses on applications for circuit reconstruction in neuroscience, which is one of the major driving forces advancing SBEM. Neuronal circuit reconstruction poses exceptional challenges to volume EM in terms of resolution, field of view, acquisition time and sample preparation. Mapping the connections between neurons in the brain is crucial for understanding information flow and information processing in the brain. However, information on the connectivity between hundreds or even thousands of neurons densely packed in neuronal microcircuits is still largely missing. Volume EM techniques such as serial section TEM, automated tape‐collecting ultramicrotome, focused ion‐beam scanning electron microscopy and SBEM (microtome serial block‐face scanning electron microscopy) are the techniques that provide sufficient resolution to resolve ultrastructural details such as synapses and provides sufficient field of view for dense reconstruction of neuronal circuits. While volume EM techniques are advancing, they are generating large data sets on the terabyte scale that require new image processing workflows and analysis tools. In this review, we present the recent advances in SBEM for circuit reconstruction in neuroscience and an overview of existing image processing and analysis pipelines. PMID:25907464

  2. Kinematics and dynamics analysis of a novel serial-parallel dynamic simulator

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Bo; Zhang, Lian Dong; Yu, Jingjing [Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, Qinhuangdao, Hebei (China)

    2016-11-15

    A serial-parallel dynamics simulator based on serial-parallel manipulator is proposed. According to the dynamics simulator motion requirement, the proposed serial-parallel dynamics simulator formed by 3-RRS (active revolute joint-revolute joint-spherical joint) and 3-SPR (Spherical joint-active prismatic joint-revolute joint) PMs adopts the outer and inner layout. By integrating the kinematics, constraint and coupling information of the 3-RRS and 3-SPR PMs into the serial-parallel manipulator, the inverse Jacobian matrix, velocity, and acceleration of the serial-parallel dynamics simulator are studied. Based on the principle of virtual work and the kinematics model, the inverse dynamic model is established. Finally, the workspace of the (3-RRS)+(3-SPR) dynamics simulator is constructed.

  3. Kinematics and dynamics analysis of a novel serial-parallel dynamic simulator

    International Nuclear Information System (INIS)

    Hu, Bo; Zhang, Lian Dong; Yu, Jingjing

    2016-01-01

    A serial-parallel dynamics simulator based on serial-parallel manipulator is proposed. According to the dynamics simulator motion requirement, the proposed serial-parallel dynamics simulator formed by 3-RRS (active revolute joint-revolute joint-spherical joint) and 3-SPR (Spherical joint-active prismatic joint-revolute joint) PMs adopts the outer and inner layout. By integrating the kinematics, constraint and coupling information of the 3-RRS and 3-SPR PMs into the serial-parallel manipulator, the inverse Jacobian matrix, velocity, and acceleration of the serial-parallel dynamics simulator are studied. Based on the principle of virtual work and the kinematics model, the inverse dynamic model is established. Finally, the workspace of the (3-RRS)+(3-SPR) dynamics simulator is constructed

  4. Recommendations for CAMAC Serial Highway drivers and LAM Graders for the SCC-L2 Serial Crate Controller

    International Nuclear Information System (INIS)

    1978-01-01

    The functional requirements of Drivers for the CAMAC Serial Highway defined in IEEE Standard 595-1976 are described. The description is independent of the implementation, and in particular no assumption is made about the boundary between hardware and software within the Driver. Topics covered are the user interface, the supporting system services required, demand handling, and a detailed discussion of the message analysis for various levels of error recovery. An appendix describes the recommended features of LAM Graders for use with the Serial Crate Controller Type L2 of IEEE Std 595-1976

  5. A psychological profile of a serial killer: a case report.

    Science.gov (United States)

    Dogra, T D; Leenaars, Antoon A; Chadha, R K; Manju, Mehta; Lalwani, Sanjeev; Sood, Mamta; Lester, David; Raina, Anupuma; Behera, C

    2012-01-01

    Serial killers have always fascinated society. A serial killer is typically defined as a perpetrator who murders three or more people over a period of time. Most reported cases of serial killers come from the United States and Canada. In India, there are few reported cases. We present, to the best of our knowledge, the first Indian case in the literature. The present case is of a 28-year-old man, Surinder Koli. The Department of Forensic Medicine & Toxicology, All India Institute of Medical Sciences, New Delphi handled the forensic study. We present a most unique psychological investigation into the mind of a serial killer.

  6. Malignant sex and aggression: an overview of serial sexual homicide.

    Science.gov (United States)

    Myers, W C; Reccoppa, L; Burton, K; McElroy, R

    1993-01-01

    Serial murderers have attracted considerable attention in the popular press and criminal justice field, but scientific literature about these individuals is limited. This article provides an overview, from a psychiatric perspective, of serial sexual homicide, one type of serial killing. Characteristics of this type of murder and of these offenders are discussed. Defining qualities and diagnoses applicable to serial sexual killers are reviewed. Various etiologic theories are discussed, with emphasis on the role of fantasy and psychodynamic explanations. Governmental agencies involved in combating this type of crime, along with the role of mental health professionals in criminal profiling, are presented. Finally, the authors explore the reaction of society to this phenomenon.

  7. Transtornos de personalidade, psicopatia e serial killers Personality disorders, psychopathy and serial killers

    Directory of Open Access Journals (Sweden)

    Hilda C P Morana

    2006-10-01

    Full Text Available OBJETIVO: Apresentar as características básicas dos diversos transtornos específicos de personalidade, mas centrando-se no transtorno de personalidade anti-social, fazendo sua diferenciação com psicopatia. O estudo ainda se propõe a abordar a figura do serial killer, apontando a presença de aspectos psicopáticos no homicídio seriado. MÉTODO: Uma revisão bibliográfica foi feita no sentido de se abordar convergências e divergências entre diversos autores sobre um assunto tão polêmico, sobretudo quanto à viabilidade de tratamento dessa clientela forense. RESULTADOS: Enquanto o transtorno de personalidade anti-social é um diagnóstico médico, pode-se entender o termo "psicopatia", pertencente à esfera psiquiátrico-forense, como um "diagnóstico legal". Não se pode falar ainda de tratamento eficaz para os chamados "serial killers". CONCLUSÃO: Os transtornos de personalidade, especialmente o tipo anti-social, representam ainda hoje um verdadeiro desafio para a psiquiatria forense. O local mais adequado e justo para seus portadores, bem como recomendação homogênea e padronizada de tratamento são questões ainda não respondidas.OBJECTIVE: To illustrate the basic characteristics of several specific personality disorders, focusing mainly in antisocial personality disorder. The differences between antisocial personality disorder and psychopathy are highlighted. Serial killers and its psychopathic aspects are also discussed. METHOD: A bibliographic review was completed in order to outline convergences and divergences among different authors about this controversial issue, especially those concerning the possibility of treatment. RESULTS: While anti-social personality disorder is a medical diagnosis, the term "psychopathy" (which belongs to the sphere of forensic psychiatry may be understood as a "legal diagnosis". It is not still possible to identify an effective treatment for serial killers. CONCLUSION: Personality disorders

  8. Selection and Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Chen, Jing

    2011-01-01

    Although it has been broadly evidenced that entrepreneurial experience plays a substantial role in the emergence of serial entrepreneurship, the debate is still going on about whether this relationship should be attributed to learning by doing or instead be explained by selection on ability. This...

  9. Volume imaging NDE and serial sectioning of carbon fiber composites

    Science.gov (United States)

    Hakim, Issa; Schumacher, David; Sundar, Veeraraghavan; Donaldson, Steven; Creuz, Aline; Schneider, Rainer; Keller, Juergen; Browning, Charles; May, Daniel; Ras, Mohamad Abo; Meyendorf, Norbert

    2018-04-01

    A composite material is a combination of two or more materials with very different mechanical, thermal and electrical properties. The various forms of composite materials, due to their high material properties, are widely used as structural materials in the aviation, space, marine, automobile, and sports industries. However, some defects like voids, delamination, or inhomogeneous fiber distribution that form during the fabricating processes of composites can seriously affect the mechanical properties of the composite material. In this study, several imaging NDE techniques such as: thermography, high frequency eddy current, ultrasonic, x-ray radiography, x-ray laminography, and high resolution x-ray CT were conducted to characterize the microstructure of carbon fiber composites. Then, a 3D analysis was implemented by the destructive technique of serial sectioning for the same sample tested by the NDE methods. To better analyze the results of this work and extract a clear volume image for all features and defects contained in the composite material, an intensive comparison was conducted among hundreds of 3D-NDE and multi serial sections' scan images showing the microstructure variation.

  10. The serial message-passing schedule for LDPC decoding algorithms

    Science.gov (United States)

    Liu, Mingshan; Liu, Shanshan; Zhou, Yuan; Jiang, Xue

    2015-12-01

    The conventional message-passing schedule for LDPC decoding algorithms is the so-called flooding schedule. It has the disadvantage that the updated messages cannot be used until next iteration, thus reducing the convergence speed . In this case, the Layered Decoding algorithm (LBP) based on serial message-passing schedule is proposed. In this paper the decoding principle of LBP algorithm is briefly introduced, and then proposed its two improved algorithms, the grouped serial decoding algorithm (Grouped LBP) and the semi-serial decoding algorithm .They can improve LBP algorithm's decoding speed while maintaining a good decoding performance.

  11. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  12. Radioimmunoassay of serum creatine kinase-BB as a tumour marker in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, R J; Rubery, E D; Jones, H M [Addenbrooke' s Hospital, Cambridge (UK)

    1980-09-27

    Brain type creatine kinase-BB (CPK-BB) was measured by radioimmunoassay in the serum of 113 women with breast cancer and 354 female controls. 80% of women with metastatic breast cancer had levels above 3 ng/ml (control range 0.5-3.7 ng/ml); the highest level was 23 ng/ml. 60% of women with local disease but no evidence of distant metastases showed levels above 3 ng/ml, the highest being 9.0 ng/ml. Of women who had presented with stage I, II, or III disease and postoperatively had no evidence of persistent disease 30% had levels above 3 ng/ml. Serial measurements in 31 patients indicated that the serum CPK-BB correlated with clinical response to treatment.

  13. Radioimmunoassay of serum creatine kinase-BB as a tumour marker in breast cancer

    International Nuclear Information System (INIS)

    Thompson, R.J.; Rubery, E.D.; Jones, H.M.

    1980-01-01

    Brain type creatine kinase-BB (CPK-BB) was measured by radioimmunoassay in the serum of 113 women with breast cancer and 354 female controls. 80% of women with metastatic breast cancer had levels above 3 ng/ml (control range 0.5-3.7 ng/ml); the highest level was 23 ng/ml. 60% of women with local disease but no evidence of distant metastases showed levels above 3 ng/ml, the highest being 9.0 ng/ml. Of women who had presented with stage I, II, or III disease and postoperatively had no evidence of persistent disease 30% had levels above 3 ng/ml. Serial measurements in 31 patients indicated that the serum CPK-BB correlated with clinical response to treatment. (author)

  14. Maternal serum alpha-fetoprotein levels are normal in Fanconi anemia: Can it be a lack of postnatal inhibition of AFP gene resulting in the elevation?

    Science.gov (United States)

    Aslan, Deniz; Karabacak, Recep Onur; Aslan, Oner Deniz

    2017-04-01

    We investigated the feasibility of using serum alpha-fetoprotein (AFP) levels as a screening test for prenatal diagnosis of Fanconi anemia (FA). Serial measurements in maternal serum were recorded. Parents, both heterozygous for FA, had declined prenatal molecular testing. The infant was born with no somatic abnormalities, and FA was confirmed by postnatal molecular analysis. Maternal serum AFP levels during each trimester of pregnancy were normal indicating that these levels cannot be used as a screening test in prenatal diagnosis. Three-year follow-up after birth showed constantly elevated serum levels in the patient from the start, suggesting a lack of postnatal inhibition on AFP gene. © 2016 Wiley Periodicals, Inc.

  15. Three more semantic serial position functions and a SIMPLE explanation.

    Science.gov (United States)

    Kelley, Matthew R; Neath, Ian; Surprenant, Aimée M

    2013-05-01

    There are innumerable demonstrations of serial position functions-with characteristic primacy and recency effects-in episodic tasks, but there are only a handful of such demonstrations in semantic memory tasks, and those demonstrations have used only two types of stimuli. Here, we provide three more examples of serial position functions when recalling from semantic memory. Participants were asked to reconstruct the order of (1) two cartoon theme song lyrics, (2) the seven Harry Potter books, and (3) two sets of movies, and all three demonstrations yielded conventional-looking serial position functions with primacy and recency effects. The data were well-fit by SIMPLE, a local distinctiveness model of memory that was originally designed to account for serial position effects in short- and long-term episodic memory. According to SIMPLE, serial position functions in both episodic and semantic memory tasks arise from the same type of processing: Items that are more separated from their close neighbors in psychological space at the time of recall will be better remembered. We argue that currently available evidence suggests that serial position functions observed when recalling items that are presumably in semantic memory arise because of the same processes as those observed when recalling items that are presumably in episodic memory.

  16. Natural born killers?: the development of the sexually sadistic serial killer.

    Science.gov (United States)

    Johnson, B R; Becker, J V

    1997-01-01

    Today's society seems enthralled with serial killers in the news and the media. Forensic psychiatrists often interview serial killers after they have been caught. There are retrospective studies and case reports of individuals who have committed sexually sadistic serial murders. However, there exists a dearth of case reports on adolescents who have expressed serious fantasies about becoming serial killer prior to actualizing their fantasy. This article presents nine clinical cases of 14- to 18-year-olds who have clinically significant fantasies of becoming a serial killer. Similarities exist in these adolescent cases when compared with retrospective studies and case reports of serial killers on the role of sexually sadistic fantasies and actual killings. Since it has been established that sexual paraphilias may develop at a young age, one can surmise that sadistic paraphilias may also develop in some adolescents. The question is posed, can we predict which of these adolescents may go on to actually become serial killers? This article focuses on how the sexually sadistic fantasy can eventually be acted out and possible motives for the act to be repeated multiple times. Finally, recommendations are made about assessing and treating a youngster who expresses violent sexually sadistic killing fantasies so that attempts can be made to interrupt the progression to actual killing.

  17. Using Serial and Discrete Digit Naming to Unravel Word Reading Processes.

    Science.gov (United States)

    Altani, Angeliki; Protopapas, Athanassios; Georgiou, George K

    2018-01-01

    During reading acquisition, word recognition is assumed to undergo a developmental shift from slow serial/sublexical processing of letter strings to fast parallel processing of whole word forms. This shift has been proposed to be detected by examining the size of the relationship between serial- and discrete-trial versions of word reading and rapid naming tasks. Specifically, a strong association between serial naming of symbols and single word reading suggests that words are processed serially, whereas a strong association between discrete naming of symbols and single word reading suggests that words are processed in parallel as wholes. In this study, 429 Grade 1, 3, and 5 English-speaking Canadian children were tested on serial and discrete digit naming and word reading. Across grades, single word reading was more strongly associated with discrete naming than with serial naming of digits, indicating that short high-frequency words are processed as whole units early in the development of reading ability in English. In contrast, serial naming was not a unique predictor of single word reading across grades, suggesting that within-word sequential processing was not required for the successful recognition for this set of words. Factor mixture analysis revealed that our participants could be clustered into two classes, namely beginning and more advanced readers. Serial naming uniquely predicted single word reading only among the first class of readers, indicating that novice readers rely on a serial strategy to decode words. Yet, a considerable proportion of Grade 1 students were assigned to the second class, evidently being able to process short high-frequency words as unitized symbols. We consider these findings together with those from previous studies to challenge the hypothesis of a binary distinction between serial/sublexical and parallel/lexical processing in word reading. We argue instead that sequential processing in word reading operates on a continuum

  18. Quantitative Proteomic Analysis of Serum Exosomes from Patients with Locally Advanced Pancreatic Cancer Undergoing Chemoradiotherapy.

    Science.gov (United States)

    An, Mingrui; Lohse, Ines; Tan, Zhijing; Zhu, Jianhui; Wu, Jing; Kurapati, Himabindu; Morgan, Meredith A; Lawrence, Theodore S; Cuneo, Kyle C; Lubman, David M

    2017-04-07

    Pancreatic cancer is the third leading cause of cancer-related death in the USA. Despite extensive research, minimal improvements in patient outcomes have been achieved. Early identification of treatment response and metastasis would be valuable to determine the appropriate therapeutic course for patients. In this work, we isolated exosomes from the serum of 10 patients with locally advanced pancreatic cancer at serial time points over a course of therapy, and quantitative analysis was performed using the iTRAQ method. We detected approximately 700-800 exosomal proteins per sample, several of which have been implicated in metastasis and treatment resistance. We compared the exosomal proteome of patients at different time points during treatment to healthy controls and identified eight proteins that show global treatment-specific changes. We then tested the effect of patient-derived exosomes on the migration of tumor cells and found that patient-derived exosomes, but not healthy controls, induce cell migration, supporting their role in metastasis. Our data show that exosomes can be reliably extracted from patient serum and analyzed for protein content. The differential loading of exosomes during a course of therapy suggests that exosomes may provide novel insights into the development of treatment resistance and metastasis.

  19. The Organized/Disorganized Typology of Serial Murder: Myth or Model?

    OpenAIRE

    Canter, David V.; Alison, Laurence J.; Alison, Emily; Wentink, Natalia

    2004-01-01

    Despite weaknesses in the organized/disorganized classification of serial killers, it is drawn on for "offender profiles," theories of offending, and in murder trials. This dichotomy was therefore tested by the multidimensional scaling of the co-occurrence of 39 aspects of serial killings derived 100 murders committed by 100 U.S. serial killers. Results revealed no distinct subsets of offense characteristics reflecting the dichotomy. They showed a subset of organized features typical of most ...

  20. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    Science.gov (United States)

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  1. A highly selective and sensitive Tb3+-acetylacetone photo probe for the assessment of acetazolamide in pharmaceutical and serum samples

    Science.gov (United States)

    Youssef, A. O.

    2018-04-01

    A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.

  2. Serial type-specific human papillomavirus (HPV) load measurement allows differentiation between regressing cervical lesions and serial virion productive transient infections

    International Nuclear Information System (INIS)

    Depuydt, Christophe E; Jonckheere, Jef; Berth, Mario; Salembier, Geert M; Vereecken, Annie J; Bogers, Johannes J

    2015-01-01

    Persistent high-risk human papillomavirus (HPV) infection is strongly associated with the development of high-grade cervical intraepithelial neoplasia (CIN) or cancer. Not all persistent infections lead to cancer. Viral load measured at a single time-point is a poor predictor of the natural history of HPV infections. However the profile of viral load evolution over time could distinguish nonprogressive from progressive (carcinogenic) infections. A retrospective natural history study was set up using a Belgian laboratory database including more than 800,000 liquid cytology specimens. All samples were submitted to qPCR identifying E6/E7 genes of 18 HPV types. Viral load changes over time were assessed by the linear regression slope. Database search identified 261 untreated women with persistent type-specific HPV DNA detected (270 infections) in at least three of the last smears for a average period of 3.2 years. Using the coefficient of determination (R²) infections could be subdivided in a latency group (n = 143; R² < 0.85) and a regressing group (n = 127; R² ≥ 0.85). In (≥3) serial viral load measurements, serial transient infections with latency is characterized by a nonlinear limited difference in decrease or increase of type-specific viral load (R² < 0.85 and slopes between 2 measurements 0.0010 and −0.0010 HPV copies/cell per day) over a longer period of time (1553 days), whereas regression of a clonal cell population is characterized by a linear (R² ≥ 0.85) decrease (−0.0033 HPV copies/cell per day) over a shorter period of time (708 days; P < 0.001). Using serial HPV type-specific viral load measurements we could for the first time identify regressing CIN2 and CIN3 lesions. Evolution of the viral load is an objective measurable indicator of the natural history of HPV infections and could be used for future triage in HPV-based cervical screening programs

  3. 8-bit serial-parallel analog-to-digital converter for fast transient recorder

    International Nuclear Information System (INIS)

    Kulka, Z.; Nadachowski, M.; Zimek, Z.

    1990-08-01

    An 8-bit serial-parallel analog-to-digital converter with a sampling frequency 5 MHz is described. The most important circuits of the device are described and parameters are given. The converter is a central part of a transient recorder type TR-1 designed for recording pulse waveforms in measurements of the kinetics of chemical reactions which are radiation-induced using an electron linear accelerator. 9 refs., 9 figs. (author)

  4. Increasing serum levels of vitamin A, D and E are associated with alterations of different inflammation markers in patients with multiple sclerosis.

    Science.gov (United States)

    Røsjø, Egil; Myhr, Kjell-Morten; Løken-Amsrud, Kristin Ingeleiv; Bakke, Søren Jacob; Beiske, Antonie G; Bjerve, Kristian S; Hovdal, Harald; Lilleås, Finn; Midgard, Rune; Pedersen, Tom; Benth, Jūratė Saltytė; Torkildsen, Øivind; Wergeland, Stig; Michelsen, Annika E; Aukrust, Pål; Ueland, Thor; Holmøy, Trygve

    2014-06-15

    To explore the relationships between vitamin A, D and E and inflammation in relapsing remitting multiple sclerosis, we assessed their associations with 11 inflammation markers in 9 serial serum samples from 85 patients, before and during interferon-β1a treatment. A negative association was found between vitamin A and pentraxin 3 independent of interferon-β1a use, whereas positive associations between vitamin D and interleukin-1 receptor antagonist and secreted frizzled-related protein 3 were seen before, and between vitamin E and chemokine (C-X-C motif) ligand 16 during interferon-β1a treatment. These findings suggest associations with diverse inflammatory pathways, which may be differentially influenced by interferon-β1a treatment. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Serum sample levels of bromine, iron, scandium and zinc in preschool children of Atayal and Bunun aborigines living in central Taiwan

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Ding-Bang Lin; Yuan-Yaw Wei

    2006-01-01

    This study determined bromine, iron, scandium and zinc serum levels in Taiwanese aboriginal preschool children living in remote mountainous areas to increase the understanding of the social, cultural, nutrient and ethnic background of the Taiwanese children. Seventy-three serum samples were taken from two ethnic groups of preschool children, Atayal aborigines (AAPC) and Bunun aborigines (BAPC). Sera of these children were freeze dried. Trace elements in sera were identified by instrumental neutron activation analysis (INAA). The accuracy and precision of INAA was evaluated using certified reference materials: Tomato Leaves (NIST-SRM 1570a) and Lichen (IAEA-336). Statistical analysis identified several different patterns for ethnic groups, gender and age via the two-tailed Student's t-test. Analytical results showed that the ranges of Br, Fe, Sc and Zn in sera were somewhat wide. The Zn serum levels (p < 0.05) and Br serum levels (p < 0.01) in the AAPC were significantly lower than those in the BAPC. However, there were no significant differences in Fe or Sc serum levels between the two groups. Analytical results were compared to published data for different counties. This study is the first investigating trace elements in Taiwanese aborigines and can be used to establish a much-needed serum element database. (author)

  6. Direct impact aerosol sampling by electrostatic precipitation

    Science.gov (United States)

    Braden, Jason D.; Harter, Andrew G.; Stinson, Brad J.; Sullivan, Nicholas M.

    2016-02-02

    The present disclosure provides apparatuses for collecting aerosol samples by ionizing an air sample at different degrees. An air flow is generated through a cavity in which at least one corona wire is disposed and electrically charged to form a corona therearound. At least one grounded sample collection plate is provided downstream of the at least one corona wire so that aerosol ions generated within the corona are deposited on the at least one grounded sample collection plate. A plurality of aerosol samples ionized to different degrees can be generated. The at least one corona wire may be perpendicular to the direction of the flow, or may be parallel to the direction of the flow. The apparatus can include a serial connection of a plurality of stages such that each stage is capable of generating at least one aerosol sample, and the air flow passes through the plurality of stages serially.

  7. Wet sample digestion for quantification of vanadium(V) in serum by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Heinemann, G.; Vogt, W.; Jacob, K.

    1999-01-01

    Three types of pressure digestion systems used prior to the determination of the ultratrace element vanadium by electrothermal atomic absorption spectrometry were evaluated: The high-pressure ashing (HPA) system, the DAB III pressure digestion system and the pressurized microwave digestion (PMD) system. Complete sample digestion and no loss of graphite tube sensitivity as well as reliable vanadium values could only be achieved with HPA digests of freeze-dried serum. The mean recovery rate was 98% and no loss of tube sensitivity could be observed. Using non-lyophilized serum the mean recovery rate was 70%. The DAB III digestion system, vicarious for closed pressure digestion in steel bombs with an allowable temperature up to about 200C, cannot be recommended to mineralize human biological material for vanadium determinations, because the remaining not completely decomposed organic compounds extracted together with the vanadium-cupferron complex caused a marked carbon-buildup and formation of carbides in the graphite tube were found to change the shape of the absorption signals distinctly, and to decline the tube sensitivity strongly (about 25%) so that reliable results cannot be achieved. The recovery rate was too low in general (about 50%). In addition, a subsequent treatment of the DAB III digests with perchloric acid was unsuccessful. The PMD system proved to be not suited, because the samples became highly contaminated by vanadium possibly from the titan seal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  8. Utilization of serial resources in libraries of selected tertiary ...

    African Journals Online (AJOL)

    Information Impact: Journal of Information and Knowledge Management ... security personnel for adequate monitoring of the serial materials, as well as the need for authors and stakeholders in education to donate more serial materials in order to enrich the collections in the library and enhance academic performance.

  9. The assessment of ovulation by a combination of ultrasound and detailed serial hormone profiles in 35 women with long-standing unexplained infertility.

    Science.gov (United States)

    Petsos, P; Chandler, C; Oak, M; Ratcliffe, W A; Wood, R; Anderson, D C

    1985-06-01

    We have examined for the presence of subtle hormonal abnormalities in women with long-standing unexplained infertility. For a full cycle serum LH, FSH, progesterone and oestradiol levels were measured about three times a week, and serial ultrasound scans of the ovaries made until the time of apparent ovulation. The results on 45 cycles in 35 women with unexplained infertility and in three normal volunteers are presented. Normal ovulatory cycles were defined by a length of 26-32 d, and progressive follicular maturation followed by disappearance or abrupt reduction in size of a follicle within 48 h of the recorded LH peak, followed by progressive and sustained rise in serum progesterone levels to more than 25 nmol/l and a luteal phase length of greater than or equal to 13 d. Thirty spontaneous cycles (28 women) were clearly normal while 15 spontaneous cycles (12 women) were abnormal. Abnormalities included luteinization of an unruptured follicle (eight cycles), absence of follicular development (two cycles), poor follicular development (two cycles), persistence of a large ovarian cyst from the preceeding cycle (two cycles) and one aluteal cycle. Six of the abnormal cycles were characterized hormonally by inappropriate elevation of serum LH levels throughout. If this study had been based only on serial ultrasound scans, all results on abnormal cycles might have been misinterpreted. If it had been conducted only with (multiple) progesterone determinations and the level of greater than 25 nmol/l had been taken as indicative of ovulation nine clearly abnormal cycles would have been considered as normal. We conclude that the combination of the hormonal and ultrasound assessment of ovulation increases our confidence for confirmation of normality and reveals various ovulatory disorders which are possibly due to an endocrinological defect or defects.

  10. Effect of impurities and post-experimental purification in SAD phasing with serial femtosecond crystallography data.

    Science.gov (United States)

    Zhang, Tao; Gu, Yuanxin; Fan, Haifu

    2016-06-01

    In serial crystallography (SX) with either an X-ray free-electron laser (XFEL) or synchrotron radiation as the light source, huge numbers of micrometre-sized crystals are used in diffraction data collection. For a SAD experiment using a derivative with introduced heavy atoms, it is difficult to completely exclude crystals of the native protein from the sample. In this paper, simulations were performed to study how the inclusion of native crystals in the derivative sample could affect the result of SAD phasing and how the post-experimental purification proposed by Zhang et al. [(2015), Acta Cryst. D71, 2513-2518] could be used to remove the impurities. A gadolinium derivative of lysozyme and the corresponding native protein were used in the test. Serial femtosecond crystallography (SFX) diffraction snapshots were generated by CrystFEL. SHELXC/D, Phaser, DM, ARP/wARP and REFMAC were used for automatic structure solution. It is shown that a small amount of impurities (snapshots from native crystals) in the set of derivative snapshots can strongly affect the SAD phasing results. On the other hand, post-experimental purification can efficiently remove the impurities, leading to results similar to those from a pure sample.

  11. IT-based Value Creation in Serial Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    serial acquirers realize IT-based value, we integrate and model the findings on individual acquisitions from the extant literature, and extend that model to explain the effects of sequential acquisitions in a growth-by-acquisition strategy. This extended model, drawing on the Resource-Based Theory......The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...

  12. The clinical utility of serum ferritin levels in patients with malignant tumors treated by radiotherapy

    International Nuclear Information System (INIS)

    Mitsuhashi, Norio; Okazaki, Atsushi; Hayakawa, Kazushige; Nakano, Takashi; Yamanaka, Mikio

    1983-01-01

    The serum levels of ferritin in 394 patients, including 339 patients with various malignant tumors and 23 with various non-malignant diseases, and 32 healthy subjects were determined. The normal levels of ferritin were 82.7 +- 42.3 ng/ml for males and 42.0 +- 36.9 ng/ml for females. The positive ratio of serum ferritin level was 28% in patients with malignant tumors and 22% in patients with non-malignant diseases. The usefulness of serum ferritin assay in screening for malignant tumors appeared to be limited. High serum levels of ferritin were found in patients with malignant lymphoma (positive ratio: 42%), pulmonary cancer (38%) and esophageal cancer (37%). According to the histological types, epidermoid cancer appeared to produce a higher serum level of ferritin than adenocarcinoma in patients with pulmonary cancer. It was interesting that malignant lymphoma had a high serum level of ferritin in spite of its low serum level of CEA. Carcinoma of the digestive tracts except for esophagus was considered to have a normal serum ferritin level in spite of the advanced stage. There was no close relationship between serum ferritin levels and CEA levels in patients with pulmonary cancer and breast cancer. Serum CEA assay was more useful for detection of tumors than serum ferritin assay in patients with breast cancer. Serum ferritin levels in patients with good prognosis decreased following radiation therapy, but those in patients with poor prognosis elevated or unchanged in spite of therapy. Therefore, serial ferritin determinations may be useful for evaluation of radiotherapy and assessment of prognosis. (J.P.N.)

  13. Serial isoelectric focusing as an effective and economic way to obtain maximal resolution and high-throughput in 2D-based comparative proteomics of scarce samples: proof-of-principle.

    Science.gov (United States)

    Farhoud, Murtada H; Wessels, Hans J C T; Wevers, Ron A; van Engelen, Baziel G; van den Heuvel, Lambert P; Smeitink, Jan A

    2005-01-01

    In 2D-based comparative proteomics of scarce samples, such as limited patient material, established methods for prefractionation and subsequent use of different narrow range IPG strips to increase overall resolution are difficult to apply. Also, a high number of samples, a prerequisite for drawing meaningful conclusions when pathological and control samples are considered, will increase the associated amount of work almost exponentially. Here, we introduce a novel, effective, and economic method designed to obtain maximum 2D resolution while maintaining the high throughput necessary to perform large-scale comparative proteomics studies. The method is based on connecting different IPG strips serially head-to-tail so that a complete line of different IPG strips with sequential pH regions can be focused in the same experiment. We show that when 3 IPG strips (covering together the pH range of 3-11) are connected head-to-tail an optimal resolution is achieved along the whole pH range. Sample consumption, time required, and associated costs are reduced by almost 70%, and the workload is reduced significantly.

  14. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  15. Opportunity recognition: delineating the process and motivators for serial entrepreneurs

    Directory of Open Access Journals (Sweden)

    Boris Urban

    2011-04-01

    Full Text Available Opportunity recognition is a fundamental research issue in entrepreneurship which this paper empirically investigates for serial entrepreneurs. Initially key definitions and boundary conditions of opportunity recognition are explored to elucidate the relevant motivators driving serial entrepreneurs. After operationalising the various concepts, data is collected by surveying serial entrepreneurs (n= 77 based on pre-determined selection criteria. Since the study’s objective is to build solid theory on these new phenomena, descriptive analysis on the empirical results is provided. To test the hypotheses inferential statistics employing parametric and non-parametric tests are used. The findings reveal that the opportunity recognition behaviours are manifest among serial entrepreneurs, with few significant differences on how many new, major businesses have been pursued, or whether they can be said to be successes.

  16. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  17. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms.

    Directory of Open Access Journals (Sweden)

    Nick De Regge

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSV is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions.Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively.While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%, the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively. The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively. Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid result indicated the

  18. IEEE 1394/firewire a low cost, high speed, digital serial bus

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.

    1997-05-01

    Does the world need yet another 1/0 bus standard? If you need fast and cheap serial video communication, then the answer is yes. As technology advances, so too must data transport mechanisms advance. You can`t expect RS-232 to support real-time digital video, and if you can`t afford expensive professional serial video interfaces, (such as Sony`s Serial Digital Interface), Firewire may be a good solution. IEEE 1394, or commonly known as Firewire, is a general purpose serial bus that meets many of the 1/0 needs of today`s video and multimedia developers. For those of you who only read the first paragraph, here`s Firewire in a nutshell: It provides a guaranteed transfer rate of 10OMbps or 20OMbps of digital data (such as video direct from camera to computer), over an inexpensive, non-proprietary serial bus. Here is a list of its features.

  19. Indexing Serialized Fiction: May the Force Be with You.

    Science.gov (United States)

    Barr, Melissa M.

    The adult novel offers indexers an unusual opportunity to create a serialized fiction index. This research paper involved designing and creating a Character Index, Thesaurus, Glossary, and Abstract (with descriptors) for 21 novels based on the "Star Wars" movies. The novels are an unusual example of serialized fiction featuring main…

  20. Stress in Harmonic Serialism

    Science.gov (United States)

    Pruitt, Kathryn Ringler

    2012-01-01

    This dissertation proposes a model of word stress in a derivational version of Optimality Theory (OT) called Harmonic Serialism (HS; Prince and Smolensky 1993/2004, McCarthy 2000, 2006, 2010a). In this model, the metrical structure of a word is derived through a series of optimizations in which the "best" metrical foot is chosen…

  1. Effect of Xylitol on Candida albicans resistance in serum (in vitro study

    Directory of Open Access Journals (Sweden)

    Ria Puspitawati

    2013-07-01

    Full Text Available Xylitol is reported to inhibit the growth of C. albicans. Objectives: Investigating serum factor role in inhibiting the growth of C. albicans and the effect of 1%, 5%, 10% xylitol on C. albicans resistance in serum in vitro. Methods: Identification of C. albicans (oral swab of candidiasis patient was conducted using CHROMAgar, confirmed by germ tube test. The cultures were serially diluted, inoculated in Saburoud Dextrose Broth (SDB contained 0% (control, 1%, 5%, or 10% xylitol, and kept for 3 or 7 days. These inoculations were then exposed to either active or inactive serum (Fetal Bovine Serum heated in 65ºC for 30 minutes for 2 hours in 37ºC. The colony forming unit (CFU of C. albicans in Saburoud Dextrose Agar (SDA were counted after 2 days. C. albicans ATCC 10231 strain was used as a comparison. One-way ANOVA with 0.05 was used. Results: After 3 days cultured in media with or without xylitol, the CFU of C. albicans exposed to active serum were significantly lower than those exposed to inactive serum (p=0.032. Although not statistically significant (p=0.689, increased concentration of xylitol lead to increased resistance of C. albicans in active serum. Only 7 day exposure of 10% xylitol resulted in significantly higher growth of C. albicans (p=0.034. No significant difference of C. albicans CFU in active or inactive serum (p=0.404. Conclusion: Serum factor has role in inhibiting C. albicans growth in vitro. Exposure of 1%, 5%, or 10% xylitol for 3 or 7 days has no significant effect on C. albicans resistance in serum.DOI: 10.14693/jdi.v16i2.98

  2. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  3. Testing Cross-Sectional Correlation in Large Panel Data Models with Serial Correlation

    Directory of Open Access Journals (Sweden)

    Badi H. Baltagi

    2016-11-01

    Full Text Available This paper considers the problem of testing cross-sectional correlation in large panel data models with serially-correlated errors. It finds that existing tests for cross-sectional correlation encounter size distortions with serial correlation in the errors. To control the size, this paper proposes a modification of Pesaran’s Cross-sectional Dependence (CD test to account for serial correlation of an unknown form in the error term. We derive the limiting distribution of this test as N , T → ∞ . The test is distribution free and allows for unknown forms of serial correlation in the errors. Monte Carlo simulations show that the test has good size and power for large panels when serial correlation in the errors is present.

  4. Forgiveness and Suicidal Behavior: Cynicism and Psychache as Serial Mediators.

    Science.gov (United States)

    Dangel, Trever J; Webb, Jon R; Hirsch, Jameson K

    2018-02-17

    Research is burgeoning regarding the beneficial association of forgiveness with numerous health-related outcomes; however, its particular relationship to suicidal behavior has received relatively little attention. Both cynicism and psychache, or agonizing psychological pain, have displayed deleterious associations with suicidal behavior, but have rarely been incorporated into more comprehensive models of suicidal behavior. Consistent with the recent development of a theoretical model regarding the forgiveness-suicidal behavior association, the present study utilized an undergraduate sample of college students (N = 312) to test a mediation-based model of the cross-sectional association of forgiveness with suicidal behavior, as serially mediated by cynicism and psychache. Dispositional forgiveness of self and forgiveness of uncontrollable situations were each indirectly associated with less suicidal behavior via less psychache. Also, dispositional forgiveness of others was indirectly associated with less suicidal behavior via less cynicism and less psychache, in a serial fashion. The present results are consistent with the extent literature on the forgiveness-suicidal behavior association, cynicism, and psychache, and pending future studies, may be utilized to inform further treatment efforts for individuals at a high risk of attempting suicide.

  5. Serum galactomannan screening for diagnosis of invasive pulmonary aspergillosis in children after stem cell transplantation or with high-risk leukemia.

    Science.gov (United States)

    Gefen, Aharon; Zaidman, Irina; Shachor-Meyouhas, Yael; Avidor, Israela; Hakim, Fahed; Weyl Ben-Arush, Myriam; Kassis, Imad

    2015-03-01

    Both transplanted and leukemia patients are at high risk (HR) for invasive pulmonary aspergillosis (IPA). Methods for rapid diagnosis are crucial. Our objective was to investigate the impact of serial serum galactomannan assay (GMA) screening on IPA diagnosis in children. Between January 2010 and December 2011, all children following stem cell transplantation (SCT) or with HR leukemia were prospectively included. Serum samples for GMA were taken once-twice weekly. Results >.5 were considered positive. Patients suspected of having IPA were stratified as possible, probable, and definite. Forty-six children (median age, 8 years) were included, 38 after SCT (32 allogeneic), 8 with HR leukemia. A total of 510 samples were taken; screening period was 1-6 months for 34 patients. GMA was negative in 28 patients, all but one without suspicion of IPA. Eighteen patients had positive GMA: while four (22%) were upgraded to probable IPA, fourteen (78%) were considered as false positives (FP), some associated with piperacillin-tazobactam treatment. GMA sensitivity and specificity were 0.8 and 0.66, respectively; positive- and negative-predictive values (PPV, NPV) were 0.22 and 0.96, respectively. GMA may have a role in evaluating HR children for IPA. Both NPV and FP rates are high. The cost benefit of early detection versus over-diagnosis should be further studied.

  6. Serial-order short-term memory predicts vocabulary development: evidence from a longitudinal study.

    Science.gov (United States)

    Leclercq, Anne-Lise; Majerus, Steve

    2010-03-01

    Serial-order short-term memory (STM), as opposed to item STM, has been shown to be very consistently associated with lexical learning abilities in cross-sectional study designs. This study investigated longitudinal predictions between serial-order STM and vocabulary development. Tasks maximizing the temporary retention of either serial-order or item information were administered to kindergarten children aged 4 and 5. At age 4, age 5, and from age 4 to age 5, serial-order STM capacities, but not item STM capacities, were specifically associated with vocabulary development. Moreover, the increase of serial-order STM capacity from age 4 to age 5 predicted the increase of vocabulary knowledge over the same time period. These results support a theoretical position that assumes an important role for serial-order STM capacities in vocabulary acquisition.

  7. A Novel Genetic Group of Bovine Hepacivirus in Archival Serum Samples from Brazilian Cattle

    Directory of Open Access Journals (Sweden)

    Cláudio W. Canal

    2017-01-01

    Full Text Available Hepatitis C virus (HCV (genus Hepacivirus; family Flaviviridae is a major human pathogen causing persistent infection and hepatic injury. Recently, emerging HCV-like viruses were described infecting wild animals, such as bats and rodents, and domestic animals, including dogs, horses, and cattle. Using degenerate primers for detecting bovine pestiviruses in a 1996 survey three bovine serum samples showed a low identity with the genus Pestivirus of the Flaviviridae family. A virus could not be isolated in cell culture. The description of bovine hepaciviruses (BovHepV in 2015 allowed us to retrospectively identify the sequences as BovHepV, with a 88.9% nucleotide identity. In a reconstructed phylogenetic tree, the Brazilian BovHepV samples grouped within the bovine HCV-like cluster in a separated terminal node that was more closely related to the putative bovine Hepacivirus common ancestor than to bovine hepaciviruses detected in Europe and Africa.

  8. Technical note: An inverse method to relate organic carbon reactivity to isotope composition from serial oxidation

    Directory of Open Access Journals (Sweden)

    J. D. Hemingway

    2017-11-01

    Full Text Available Serial oxidation coupled with stable carbon and radiocarbon analysis of sequentially evolved CO2 is a promising method to characterize the relationship between organic carbon (OC chemical composition, source, and residence time in the environment. However, observed decay profiles depend on experimental conditions and oxidation pathway. It is therefore necessary to properly assess serial oxidation kinetics before utilizing decay profiles as a measure of OC reactivity. We present a regularized inverse method to estimate the distribution of OC activation energy (E, a proxy for bond strength, using serial oxidation. Here, we apply this method to ramped temperature pyrolysis or oxidation (RPO analysis but note that this approach is broadly applicable to any serial oxidation technique. RPO analysis directly compares thermal reactivity to isotope composition by determining the E range for OC decaying within each temperature interval over which CO2 is collected. By analyzing a decarbonated test sample at multiple masses and oven ramp rates, we show that OC decay during RPO analysis follows a superposition of parallel first-order kinetics and that resulting E distributions are independent of experimental conditions. We therefore propose the E distribution as a novel proxy to describe OC thermal reactivity and suggest that E vs. isotope relationships can provide new insight into the compositional controls on OC source and residence time.

  9. Technical note: An inverse method to relate organic carbon reactivity to isotope composition from serial oxidation

    Science.gov (United States)

    Hemingway, Jordon D.; Rothman, Daniel H.; Rosengard, Sarah Z.; Galy, Valier V.

    2017-11-01

    Serial oxidation coupled with stable carbon and radiocarbon analysis of sequentially evolved CO2 is a promising method to characterize the relationship between organic carbon (OC) chemical composition, source, and residence time in the environment. However, observed decay profiles depend on experimental conditions and oxidation pathway. It is therefore necessary to properly assess serial oxidation kinetics before utilizing decay profiles as a measure of OC reactivity. We present a regularized inverse method to estimate the distribution of OC activation energy (E), a proxy for bond strength, using serial oxidation. Here, we apply this method to ramped temperature pyrolysis or oxidation (RPO) analysis but note that this approach is broadly applicable to any serial oxidation technique. RPO analysis directly compares thermal reactivity to isotope composition by determining the E range for OC decaying within each temperature interval over which CO2 is collected. By analyzing a decarbonated test sample at multiple masses and oven ramp rates, we show that OC decay during RPO analysis follows a superposition of parallel first-order kinetics and that resulting E distributions are independent of experimental conditions. We therefore propose the E distribution as a novel proxy to describe OC thermal reactivity and suggest that E vs. isotope relationships can provide new insight into the compositional controls on OC source and residence time.

  10. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    -13, and VEGF, LH plasma levels vs. EDTA plasma: IL-2 and IL-4. CONCLUSION: Stored serum, LH plasma, and EDTA plasma from clinical trials can be used for analysis of circulating cytokines and proteins. Variations in measurements occur, but are within reasonable ranges. The optimal type of media...... in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...... on different dates was reasonable. However, samples run on different dates could exhibit different absolute values. The 75th percentile of the fold differences for samples run on different dates was 2.2. No significant difference was found between one and four freeze-thaw cycles (except for HGF...

  11. Detection of cryoglobulins in serum of Caspian miniature horse

    Directory of Open Access Journals (Sweden)

    Atyabi, N,

    2012-06-01

    Full Text Available Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was performed on normal serum samples and also on four serum samples containing precipitates using an automated electrophoresis system on cellulose acetate strips. In addition Ig isotypes detection (IgG, IgM and IgA was performed on both precipitates and serum containing precipitates using single radio immunediffusion method (SRID. A narrow-based peak on gamma region of precipitate acetate cellulose strips was observed. Precipitate concentrations were strikingly higher than normal concentration of serum immuneglobulins. It can be suggested that cryoglobulin concentration in a proportion of Caspian miniature horse is higher than other equides may be in relation with animal susceptibility to neoplasias such as lymphoma and leukemia.

  12. Antisocial personality disorder, sexual sadism, malignant narcissism, and serial murder.

    Science.gov (United States)

    Geberth, V J; Turco, R N

    1997-01-01

    This paper examines the research on serial murder and its relationship to antisocial personality disorder and sexual sadism. The concept of malignant narcissism is also discussed. Case studies of serial killers are examined regarding the nature of sexual violation and crime scene behavior.

  13. Hemispatial neglect and serial order in verbal working memory.

    Science.gov (United States)

    Antoine, Sophie; Ranzini, Mariagrazia; van Dijck, Jean-Philippe; Slama, Hichem; Bonato, Mario; Tousch, Ann; Dewulf, Myrtille; Bier, Jean-Christophe; Gevers, Wim

    2018-01-09

    Working memory refers to our ability to actively maintain and process a limited amount of information during a brief period of time. Often, not only the information itself but also its serial order is crucial for good task performance. It was recently proposed that serial order is grounded in spatial cognition. Here, we compared performance of a group of right hemisphere-damaged patients with hemispatial neglect to healthy controls in verbal working memory tasks. Participants memorized sequences of consonants at span level and had to judge whether a target consonant belonged to the memorized sequence (item task) or whether a pair of consonants were presented in the same order as in the memorized sequence (order task). In line with this idea that serial order is grounded in spatial cognition, we found that neglect patients made significantly more errors in the order task than in the item task compared to healthy controls. Furthermore, this deficit seemed functionally related to neglect severity and was more frequently observed following right posterior brain damage. Interestingly, this specific impairment for serial order in verbal working memory was not lateralized. We advance the hypotheses of a potential contribution to the deficit of serial order in neglect patients of either or both (1) reduced spatial working memory capacity that enables to keep track of the spatial codes that provide memorized items with a positional context, (2) a spatial compression of these codes in the intact representational space. © 2018 The British Psychological Society.

  14. Radioimmunologic determination of alphafetoproteins concentration in blood serum samples and in the amniotic fluid in healthy pregnant women in the 2 trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Skalba, P; Krupa, B; Rozmus, M; Brudnik, K; Kokocinska, D; Rajs, M [Slaska Akademia Medyczna, Katowice (Poland)

    1980-01-01

    Radioimmunologic technique of double antibodies was used for the determination of alphafetoprotein (AFP) concentrations in blood serum samples from 223 healthy, pregnant women with single pregnancies and in amniotic fluid samples from 43 donors. The gestational age during samples collection was 10 to 25 weeks. The AFP preparation for the test was supplied by the International Agency of Cancer Research, anti-AFP antibodies produced by Behringwerke and personally produced rabbit antiglobulin antibodies. The results of the AFP determinations in the blood and amniotic fluid samples were presented in tables in form of medians. The serum AFP concentrations overranging the double medians value were met in 8.5%, overranging the triple medians - in 2.6%. Repeat determinations decreased the number of false positive results for about 50%. The results permit to issue a conclusion that the used technique is fully applicable for scan examinations in prenatal diagnosis of fetal nervous system malformations.

  15. Attractive Serial Dependence in the Absence of an Explicit Task.

    Science.gov (United States)

    Fornaciai, Michele; Park, Joonkoo

    2018-03-01

    Attractive serial dependence refers to an adaptive change in the representation of sensory information, whereby a current stimulus appears to be similar to a previous one. The nature of this phenomenon is controversial, however, as serial dependence could arise from biased perceptual representations or from biased traces of working memory representation at a decisional stage. Here, we demonstrated a neural signature of serial dependence in numerosity perception emerging early in the visual processing stream even in the absence of an explicit task. Furthermore, a psychophysical experiment revealed that numerosity perception is biased by a previously presented stimulus in an attractive way, not by repulsive adaptation. These results suggest that serial dependence is a perceptual phenomenon starting from early levels of visual processing and occurring independently from a decision process, which is consistent with the view that these biases smooth out noise from neural signals to establish perceptual continuity.

  16. Using Behavior Sequence Analysis to Map Serial Killers' Life Histories.

    Science.gov (United States)

    Keatley, David A; Golightly, Hayley; Shephard, Rebecca; Yaksic, Enzo; Reid, Sasha

    2018-03-01

    The aim of the current research was to provide a novel method for mapping the developmental sequences of serial killers' life histories. An in-depth biographical account of serial killers' lives, from birth through to conviction, was gained and analyzed using Behavior Sequence Analysis. The analyses highlight similarities in behavioral events across the serial killers' lives, indicating not only which risk factors occur, but the temporal order of these factors. Results focused on early childhood environment, indicating the role of parental abuse; behaviors and events surrounding criminal histories of serial killers, showing that many had previous convictions and were known to police for other crimes; behaviors surrounding their murders, highlighting differences in victim choice and modus operandi; and, finally, trial pleas and convictions. The present research, therefore, provides a novel approach to synthesizing large volumes of data on criminals and presenting results in accessible, understandable outcomes.

  17. Keratinocytes propagated in serum-free, feeder-free culture conditions fail to form stratified epidermis in a reconstituted skin model.

    Directory of Open Access Journals (Sweden)

    Rebecca Lamb

    Full Text Available Primary human epidermal stem cells isolated from skin tissues and subsequently expanded in tissue culture are used for human therapeutic use to reconstitute skin on patients and to generate artificial skin in culture for academic and commercial research. Classically, epidermal cells, known as keratinocytes, required fibroblast feeder support and serum-containing media for serial propagation. In alignment with global efforts to remove potential animal contaminants, many serum-free, feeder-free culture methods have been developed that support derivation and growth of these cells in 2-dimensional culture. Here we show that keratinocytes grown continually in serum-free and feeder-free conditions were unable to form into a stratified, mature epidermis in a skin equivalent model. This is not due to loss of cell potential as keratinocytes propagated in serum-free, feeder-free conditions retain their ability to form stratified epidermis when re-introduced to classic serum-containing media. Extracellular calcium supplementation failed to improve epidermis development. In contrast, the addition of serum to commercial, growth media developed for serum-free expansion of keratinocytes facilitated 3-dimensional stratification in our skin equivalent model. Moreover, the addition of heat-inactivated serum improved the epidermis structure and thickness, suggesting that serum contains factors that both aid and inhibit stratification.

  18. Serial murder by healthcare professionals.

    Science.gov (United States)

    Yorker, Beatrice Crofts; Kizer, Kenneth W; Lampe, Paula; Forrest, A R W; Lannan, Jacquetta M; Russell, Donna A

    2008-01-01

    The prosecution of Charles Cullen, a nurse who killed at least 40 patients over a 16-year period, highlights the need to better understand the phenomenon of serial murder by healthcare professionals. The authors conducted a LexisNexis search which yielded 90 criminal prosecutions of healthcare providers that met inclusion criteria for serial murder of patients. In addition we reviewed epidemiologic studies, toxicology evidence, and court transcripts, to provide data on healthcare professionals who have been prosecuted between 1970 and 2006. Fifty-four of the 90 have been convicted; 45 for serial murder, four for attempted murder, and five pled guilty to lesser charges. Twenty-four more have been indicted and are either awaiting trial or the outcome has not been published. The other 12 prosecutions had a variety of legal outcomes. Injection was the main method used by healthcare killers followed by suffocation, poisoning, and tampering with equipment. Prosecutions were reported from 20 countries with 40% taking place in the United States. Nursing personnel comprised 86% of the healthcare providers prosecuted; physicians 12%, and 2% were allied health professionals. The number of patient deaths that resulted in a murder conviction is 317 and the number of suspicious patient deaths attributed to the 54 convicted caregivers is 2113. These numbers are disturbing and demand that systemic changes in tracking adverse patient incidents associated with presence of a specific healthcare provider be implemented. Hiring practices must shift away from preventing wrongful discharge or denial of employment lawsuits to protecting patients from employees who kill.

  19. Selection and Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Chen, Jing

    2013-01-01

    There is substantial evidence that serial entrepreneurs outperform de novo entrepreneurs. But is this positive association between prior experience and performance the result of learning by doing or of selection on ability? This paper proposes a strategy that combines the fixed-effects model and IV...... when the analysis focuses on founding new startups in sectors closely related to entrepreneurs' previous ventures....

  20. Serial position effects in mild cognitive impairment.

    Science.gov (United States)

    Howieson, Diane B; Mattek, Nora; Seeyle, Adriana M; Dodge, Hiroko H; Wasserman, Dara; Zitzelberger, Tracy; Jeffrey, Kaye

    2011-03-01

    Mild cognitive impairment (MCI) is often associated with the preclinical phase of Alzheimer's disease (AD). Special scoring of word-list recall data for serial position has been suggested to improve discrimination of normal aging from dementia. We examined serial position effects in word-list recall for MCI participants compared to Alzheimer patients and controls. Individuals with MCI, like Alzheimer patients, had a diminished primacy effect in recalling words from a list. No alternative scoring system was better than standard scoring of word-list recall in distinguishing MCI patients from controls. Retention weighted scoring improved the discrimination of MCI and AD groups.

  1. A new fixed-target approach for serial crystallography at synchrotron light sources and X-ray free electron lasers

    International Nuclear Information System (INIS)

    Roedig, Philip

    2017-07-01

    In the framework of this thesis, a new method for high-speed fixed-target serial crystallography experiments and its applicability to biomacromolecular crystallography at both synchrotron light sources and X-ray free electron lasers (XFELs) is presented. The method is based on a sample holder, which can carry up to 20,000 microcrystals and which is made of single-crystalline silicon. Using synchrotron radiation, the structure of Operophtera brumata cytoplasmic polyhedrosis virus type 18 polyhedrin, lysozyme and cubic insulin was determined by collecting X-ray diffraction data from multiple microcrystals. Data collection was shown to be possible at both cryogenic and ambient conditions. For room-temperature measurements, both global and specific indications of radiation damage were investigated and characterized. Due to the sieve-like structure of the chip, the microcrystals tend to arrange themselves according to the micropore pattern, which allows for efficient sampling of the sample material. In combination with a high-speed scanning stage, the sample holder was furthermore shown to be highly suitable for serial femtosecond crystallography experiments. By fast raster scanning of the chip through the pulsed X-ray beam of an XFEL, structure determination of a virus, using the example of bovine enterovirus type 2, has been demonstrated at an XFEL for the first time. Hit rates of up to 100% were obtained by the presented method, which refers to a reduction in sample consumption by at least three orders of magnitude with respect to common liquid-jet injection methods used for sample delivery. In this way, the typical time needed for data collection in serial femtosecond crystallography is significantly decreased. The presented technique for sample loading of the chip is easy to learn and results in efficient removal of the surrounding mother liquor, thereby reducing the generated background signal. Since the chip is made of single-crystalline silicon, in principle no

  2. A new fixed-target approach for serial crystallography at synchrotron light sources and X-ray free electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Roedig, Philip

    2017-07-15

    In the framework of this thesis, a new method for high-speed fixed-target serial crystallography experiments and its applicability to biomacromolecular crystallography at both synchrotron light sources and X-ray free electron lasers (XFELs) is presented. The method is based on a sample holder, which can carry up to 20,000 microcrystals and which is made of single-crystalline silicon. Using synchrotron radiation, the structure of Operophtera brumata cytoplasmic polyhedrosis virus type 18 polyhedrin, lysozyme and cubic insulin was determined by collecting X-ray diffraction data from multiple microcrystals. Data collection was shown to be possible at both cryogenic and ambient conditions. For room-temperature measurements, both global and specific indications of radiation damage were investigated and characterized. Due to the sieve-like structure of the chip, the microcrystals tend to arrange themselves according to the micropore pattern, which allows for efficient sampling of the sample material. In combination with a high-speed scanning stage, the sample holder was furthermore shown to be highly suitable for serial femtosecond crystallography experiments. By fast raster scanning of the chip through the pulsed X-ray beam of an XFEL, structure determination of a virus, using the example of bovine enterovirus type 2, has been demonstrated at an XFEL for the first time. Hit rates of up to 100% were obtained by the presented method, which refers to a reduction in sample consumption by at least three orders of magnitude with respect to common liquid-jet injection methods used for sample delivery. In this way, the typical time needed for data collection in serial femtosecond crystallography is significantly decreased. The presented technique for sample loading of the chip is easy to learn and results in efficient removal of the surrounding mother liquor, thereby reducing the generated background signal. Since the chip is made of single-crystalline silicon, in principle no

  3. A combination strategy for tracking the serial criminal

    Science.gov (United States)

    He, Chuan; Zhang, Yuan-Biao; Wan, Jiadi; Yu, Wenjing

    2010-08-01

    We build a Geographic Profiling Model to generate the criminal's geographical profile, by combining two complementary strategies: the Spatial Distribution Strategy and the Probability Distance Strategy. In the first strategy, we designate the mean of all the known crime sites as the anchor point, and build a Standard Deviational Ellipse Model, considering the effect of landscape. In the second strategy, we take many factors such as the buffer zone and distance decay theory into consideration and calculate the probability of the offender's residence in a certain area by using the Bayesian Theorem and the Rossmo Algorithm. Then, we combine the result of two strategies and get three search areas suit different conditions of the police to track the serial criminal. Apply the model to the English serial killer Peter Sutcliffe's case, the calculation result shows that the model can effectively be used to track serial criminal.

  4. Spatial attention interacts with serial-order retrieval from verbal working memory.

    Science.gov (United States)

    van Dijck, Jean-Philippe; Abrahamse, Elger L; Majerus, Steve; Fias, Wim

    2013-09-01

    The ability to maintain the serial order of events is recognized as a major function of working memory. Although general models of working memory postulate a close link between working memory and attention, such a link has so far not been proposed specifically for serial-order working memory. The present study provided the first empirical demonstration of a direct link between serial order in verbal working memory and spatial selective attention. We show that the retrieval of later items of a sequence stored in working memory-compared with that of earlier items-produces covert attentional shifts toward the right. This observation suggests the conceptually surprising notion that serial-order working memory, even for nonspatially defined verbal items, draws on spatial attention.

  5. Serial CSTR digester configuration for improving biogas production from manure

    DEFF Research Database (Denmark)

    Boe, Kanokwan; Angelidaki, Irini

    2009-01-01

    distribution ratio of 80/20 and 90/10, and total HRT of 15 days. The results showed that the serial CSTR could obtain 11% higher biogas yield compared to the single CSTR. The increased biogas yield in the serial CSTR was mainly from the second reactor, which accounted for 16% and 12% of total biogas yield......A new configuration of manure digesters for improving biogas production has been investigated in laboratory scale. A single thermophilic continuous-flow stirred tank reactor (CSTR) operated with a hydraulic retention time (HRT) of 15 days was compared to a serial CSTR configuration with volume...

  6. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  7. Whole-pattern fitting technique in serial femtosecond nanocrystallography

    Directory of Open Access Journals (Sweden)

    Ruben A. Dilanian

    2016-03-01

    Full Text Available Serial femtosecond X-ray crystallography (SFX has created new opportunities in the field of structural analysis of protein nanocrystals. The intensity and timescale characteristics of the X-ray free-electron laser sources used in SFX experiments necessitate the analysis of a large collection of individual crystals of variable shape and quality to ultimately solve a single, average crystal structure. Ensembles of crystals are commonly encountered in powder diffraction, but serial crystallography is different because each crystal is measured individually and can be oriented via indexing and merged into a three-dimensional data set, as is done for conventional crystallography data. In this way, serial femtosecond crystallography data lie in between conventional crystallography data and powder diffraction data, sharing features of both. The extremely small sizes of nanocrystals, as well as the possible imperfections of their crystallite structure, significantly affect the diffraction pattern and raise the question of how best to extract accurate structure-factor moduli from serial crystallography data. Here it is demonstrated that whole-pattern fitting techniques established for one-dimensional powder diffraction analysis can be feasibly extended to higher dimensions for the analysis of merged SFX diffraction data. It is shown that for very small crystals, whole-pattern fitting methods are more accurate than Monte Carlo integration methods that are currently used.

  8. Origin of DNA in human serum and usefulness of serum as a material for DNA typing.

    Science.gov (United States)

    Takayama, T; Yamada, S; Watanabe, Y; Hirata, K; Nagai, A; Nakamura, I; Bunai, Y; Ohya, I

    2001-06-01

    The aims of this study were to clarify the origin of DNA in human serum and to investigate whether serum is a material available for DNA typing in routine forensic practice. Blood was donated from 10 healthy adult volunteers and stored for up to 8 days, at 4 degrees C and at room temperature. The serum DNA concentration at zero time was in the range of 5.6 to 21.8 ng/ml with a mean of 12.2+/-1.6 ng/ml. The concentrations increased with storage time. On agarose gel electrophoresis, all serum samples showed ladder patterns and the size of each band was an integer multiple of approximately 180 bp considered to be characteristic of apoptosis. DNA typing from DNA released by apoptosis was possible. Exact DNA typing of D1S80, HLA DQA1, PM, CSF1PO, TPOX, TH01 and vWA was possible for each sample. These results indicate that serum contains fragmented DNA derived from apoptosis of leukocytes, especially neutrophils, and that fragmented DNA is an appropriate material for DNA typing.

  9. Precision, accuracy, cross reactivity and comparability of serum indices measurement on Abbott Architect c8000, Beckman Coulter AU5800 and Roche Cobas 6000 c501 clinical chemistry analyzers.

    Science.gov (United States)

    Nikolac Gabaj, Nora; Miler, Marijana; Vrtarić, Alen; Hemar, Marina; Filipi, Petra; Kocijančić, Marija; Šupak Smolčić, Vesna; Ćelap, Ivana; Šimundić, Ana-Maria

    2018-04-25

    The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.

  10. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  11. Serial killer: il database mondiale

    Directory of Open Access Journals (Sweden)

    Gaetano parente

    2016-07-01

    Full Text Available The complex and multisided study of serial killers is partly made difficult by the current level of progress that has led these deviant people to evolve in relation to the aspects of shrewdness (concerning the staging and mobility. Despite the important work of some scholars who proposed important theories, all this shows that, concerning serial murders, it is still particularly frequent not to pay attention to links among homicides committed by the same person but in different parts of the world. It is therefore crucial to develop a worldwide database that allows all police forces to access information collected on crime scenes of murders which are particularly absurd and committed without any apparent reason. It will then be up to the profiler, through ad hoc and technologically advanced tools, to collect this information on the crime scene that would be made available to all police forces thanks to the worldwide database.

  12. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  13. Numerical discrepancy between serial and MPI parallel computations

    Directory of Open Access Journals (Sweden)

    Sang Bong Lee

    2016-09-01

    Full Text Available Numerical simulations of 1D Burgers equation and 2D sloshing problem were carried out to study numerical discrepancy between serial and parallel computations. The numerical domain was decomposed into 2 and 4 subdomains for parallel computations with message passing interface. The numerical solution of Burgers equation disclosed that fully explicit boundary conditions used on subdomains of parallel computation was responsible for the numerical discrepancy of transient solution between serial and parallel computations. Two dimensional sloshing problems in a rectangular domain were solved using OpenFOAM. After a lapse of initial transient time sloshing patterns of water were significantly different in serial and parallel computations although the same numerical conditions were given. Based on the histograms of pressure measured at two points near the wall the statistical characteristics of numerical solution was not affected by the number of subdomains as much as the transient solution was dependent on the number of subdomains.

  14. A comparison of serial order short-term memory effects across verbal and musical domains.

    Science.gov (United States)

    Gorin, Simon; Mengal, Pierre; Majerus, Steve

    2018-04-01

    Recent studies suggest that the mechanisms involved in the short-term retention of serial order information may be shared across short-term memory (STM) domains such as verbal and visuospatial STM. Given the intrinsic sequential organization of musical material, the study of STM for musical information may be particularly informative about serial order retention processes and their domain-generality. The present experiment examined serial order STM for verbal and musical sequences in participants with no advanced musical expertise and experienced musicians. Serial order STM for verbal information was assessed via a serial order reconstruction task for digit sequences. In the musical domain, serial order STM was assessed using a novel melodic sequence reconstruction task maximizing the retention of tone order information. We observed that performance for the verbal and musical tasks was characterized by sequence length as well as primacy and recency effects. Serial order errors in both tasks were characterized by similar transposition gradients and ratios of fill-in:infill errors. These effects were observed for both participant groups, although the transposition gradients and ratios of fill-in:infill errors showed additional specificities for musician participants in the musical task. The data support domain-general serial order STM effects but also suggest the existence of additional domain-specific effects. Implications for models of serial order STM in verbal and musical domains are discussed.

  15. S3-1: The Serial Dependence of Visual Perception

    Directory of Open Access Journals (Sweden)

    David Whitney

    2012-10-01

    Full Text Available In our moment-to-moment perceptual experience, visual scenes can change, but objects rarely spontaneously come into or out of existence. The visual system may therefore delicately balance the need to optimize sensitivity to image changes (e.g., by adapting to changes in color, orientation, object identity, etc with the desire to represent the temporal continuity of objects—the likelihood that objects perceived at this moment tend to exist in subsequent moments. One way that the visual system may promote such stability is through the introduction of serial dependence to visual perception: by biasing the current percept toward what was seen at previous moments, the brain could compensate for variability in visual input that might otherwise disrupt perceptual continuity. Here, in two sets of experiments, we tested for serial dependence in visual perception of orientation and facial expression. We found that on a given trial, a subject's perception of the orientation of a grating reflected not only the currently viewed stimulus, but also a systematic attraction toward the orientations of the previously viewed stimuli. We found the same serial dependence in the perception of facial expression. This perceptual attraction extended over several trials and seconds, and displayed clear tuning to the difference (in orientation or facial expression between the sequential stimuli. Furthermore, serial dependence in object perception was spatially specific and selective to the attended object within a scene. Several control experiments showed that the perceptual serial dependence we report cannot be explained by effects of priming, known hysteresis effects, visual short-term memory, or expectation. Our results reveal a systematic influence of recent visual experiences on perception at any given moment: visual percepts, even of unambiguous stimuli, are attracted toward what was previously seen. We propose that such serial dependence helps to maintain

  16. Some Considerations on Seriality and Synchronicity

    OpenAIRE

    Elena Nechita

    2010-01-01

    This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  17. A 16:1 Serializer ASIC for Data Transmission at 5 Gbps

    CERN Document Server

    Gong, D; The ATLAS collaboration

    2010-01-01

    A high speed, low power 16:1 serializer has been developed with a commercial 0.25 μm silicon-on-sapphire CMOS technology. The serializer operates from 4.0 to 5.7 Gbps. Total jitter is 62 ps and the eye openning of the bathtub curve is 122 ps at bit rate error of 10-12 at 5 Gbps. Power consumption is 463 mW at 5 Gbps. A proton beam test indicates the serializer is suitable for applications in high energy physics experiments.

  18. Diagnostic Value of Serial Measurement of C-Reactive Protein in the Detection of a Surgical Complication after Laparoscopic Bowel Resection for Endometriosis

    DEFF Research Database (Denmark)

    Riiskjær, Mads; Forman, Axel; Kesmodel, Ulrik Schiøler

    2016-01-01

    AIMS: The study aimed to assess the diagnostic value of serial monitoring of biochemical inflammatory markers (C-reactive protein (CRP) and white blood cell (WBC) count) in the postoperative diagnosis of anastomotic leakage or ureteral injury after bowel resection for deep infiltrating endometrio......AIMS: The study aimed to assess the diagnostic value of serial monitoring of biochemical inflammatory markers (C-reactive protein (CRP) and white blood cell (WBC) count) in the postoperative diagnosis of anastomotic leakage or ureteral injury after bowel resection for deep infiltrating...... endometriosis. METHODS: This is a review of prospectively collected data from 217 patients who underwent laparoscopic bowel resection for endometriosis from January 2009 to April 2015. Patients with an anastomotic leakage or ureteral injury were identified and classified. RESULTS: The frequency of anastomotic...... leakage requiring reoperation was 8.3%. The frequency of ureteral injury was 4.6%. Median time to diagnosis was 6 days for anastomotic leakage and 8 days for ureteral injury. The daily mean values of serum CRP were significantly higher in patients with a surgical complication starting at the second...

  19. Higher Ratio of Serum Alpha-Fetoprotein Could Predict Outcomes in Patients with Hepatitis B Virus-Associated Hepatocellular Carcinoma and Normal Alanine Aminotransferase.

    Directory of Open Access Journals (Sweden)

    Young-Il Kim

    Full Text Available The role of serum alpha-fetoprotein (AFP levels in the surveillance and diagnosis of hepatocellular carcinoma (HCC is controversial. The aim of this study was to investigate the value of serially measured serum AFP levels in HCC progression or recurrence after initial treatment.A total of 722 consecutive patients newly diagnosed with HCC and treated at the National Cancer Center, Korea, between January 2004 and December 2009 were enrolled. The AFP ratios between 4-8 weeks post-treatment and those at the time of HCC progression or recurrence were obtained. Multivariate logistic regression analysis was performed to correlate the post-treatment AFP ratios with the presence of HCC progression or recurrence.The etiology of HCC was related to chronic hepatitis B virus (HBV infection in 562 patients (77.8%, chronic hepatitis C virus (HCV infection in 74 (10.2%, and non-viral cause in 86 (11.9%. There was a significant decrease in serum AFP levels from the baseline to 4 to 8 weeks after treatment (median AFP, 319.6 ng/mL vs. 49.6 ng/mL; p 1.0 was an independently associated with HCC progression or recurrence. Among the different causes of HCC analyzed, this association was significant only for HCC related to chronic hepatitis B (p< 0.001 and non-viral causes (p<0.05, and limited only to patients who had normal alanine aminotransferase (ALT levels.Serial measurements of serum AFP ratios could be helpful in detecting progression or recurrence in treated patients with HBV-HCC and normal ALT.

  20. Higher Ratio of Serum Alpha-Fetoprotein Could Predict Outcomes in Patients with Hepatitis B Virus-Associated Hepatocellular Carcinoma and Normal Alanine Aminotransferase

    Science.gov (United States)

    Park, Joong-Won

    2016-01-01

    Background The role of serum alpha-fetoprotein (AFP) levels in the surveillance and diagnosis of hepatocellular carcinoma (HCC) is controversial. The aim of this study was to investigate the value of serially measured serum AFP levels in HCC progression or recurrence after initial treatment. Methods A total of 722 consecutive patients newly diagnosed with HCC and treated at the National Cancer Center, Korea, between January 2004 and December 2009 were enrolled. The AFP ratios between 4–8 weeks post-treatment and those at the time of HCC progression or recurrence were obtained. Multivariate logistic regression analysis was performed to correlate the post-treatment AFP ratios with the presence of HCC progression or recurrence. Results The etiology of HCC was related to chronic hepatitis B virus (HBV) infection in 562 patients (77.8%), chronic hepatitis C virus (HCV) infection in 74 (10.2%), and non-viral cause in 86 (11.9%). There was a significant decrease in serum AFP levels from the baseline to 4 to 8 weeks after treatment (median AFP, 319.6 ng/mL vs. 49.6 ng/mL; p 1.0 was an independently associated with HCC progression or recurrence. Among the different causes of HCC analyzed, this association was significant only for HCC related to chronic hepatitis B (p< 0.001) and non-viral causes (p<0.05), and limited only to patients who had normal alanine aminotransferase (ALT) levels. Conclusion Serial measurements of serum AFP ratios could be helpful in detecting progression or recurrence in treated patients with HBV-HCC and normal ALT. PMID:27304617

  1. Serial Learning Process: Test of Chaining, Position, and Dual-Process Hypotheses

    Science.gov (United States)

    Giurintano, S. L.

    1973-01-01

    The chaining, position, and dual-process hypotheses of serial learning (SL) as well as serial recall, reordering, and relearning of paired-associate learning were examined to establish learning patterns. Results provide evidence for dual-process hypothesis. (DS)

  2. Studies on the direct radioimmunological determination of triiodothyronine in serum

    International Nuclear Information System (INIS)

    Meinhold, H.; Wenzel, K.W.

    1974-01-01

    The production of highly specific antisera for T 3 and the development of a sensitive radioimmunological procedure for the direct measurement of T 3 in serum is described. Anti-T 3 sera were produced by immunizing rabbits with conjugates of T 3 and bovine albumin, human albumin, and ovalbumin. The various antisera produced showed very little variance in quality and could be used for the direct radioimmunological determination of serum-T 3 with final dilutions between 1:60,000 and 1:300,000. Binding of T 3 to thyroid-hormone-binding serum proteins was inhibited by 8-anilinonaphthalene-1-sulfonic acid. This compound showed better inhibition properties than merthiolate and sodium salicylate. The separation of free and bound hormone was performed by the double antibody technique. The separation by dextran-coated charcoal and ion-exchange resin leads to a decrease of the antibody-bound activity. The validation of the method used was tested by serial dilutions of sera, recovery experiments, and by comparing the serum-T 3 values measured in ethanol extracts with those values obtained by the direct measurement in unextracted serum. The lower limit of detection was approximately 0.18 nmol/l serum. The variation coefficient for the intraassay reproducibility was between 4.3 and 6.1%, for the interassay reproducibility between 7.7 and 13.9%. Measured mean T 3 concentrations for various thyroid states were as follows: Normals: 1.77 nmol/l (1.15 μg/l), normal females on contraceptives: 2.03 nmol/l (1.32 μg/l), pregnants: 2.73 nmol/l (1.78 μg/l), hyperthyroidism: 6.30 nmol/l (4.10 μg/l), T 3 -toxicosis: 3.69 nmol/l (2.40 μg/l). In hypothyroidism T 3 ranged from [de

  3. The Effect of Concurrent Semantic Categorization on Delayed Serial Recall

    Science.gov (United States)

    Acheson, Daniel J.; MacDonald, Maryellen C.; Postle, Bradley R.

    2011-01-01

    The influence of semantic processing on the serial ordering of items in short-term memory was explored using a novel dual-task paradigm. Participants engaged in 2 picture-judgment tasks while simultaneously performing delayed serial recall. List material varied in the presence of phonological overlap (Experiments 1 and 2) and in semantic content…

  4. Infants' Memory Processing of a Serial List: List Length Effects.

    Science.gov (United States)

    Gulya, Michele; Sweeney, Becky; Rovee-Collier, Carolyn

    1999-01-01

    Three experiments demonstrated that increasing the length of a mobile serial list impaired 6-month olds' memory for serial order. Findings indicated that the primacy effect was absent on a 24-hour delayed recognition test and was exhibited on a reactivation test, adding to growing evidence that young infants possess two functionally distinct…

  5. Position Analysis of a Hybrid Serial-Parallel Manipulator in Immersion Lithography

    Directory of Open Access Journals (Sweden)

    Jie-jie Shao

    2015-01-01

    Full Text Available This paper proposes a novel hybrid serial-parallel mechanism with 6 degrees of freedom. The new mechanism combines two different parallel modules in a serial form. 3-P̲(PH parallel module is architecture of 3 degrees of freedom based on higher joints and specializes in describing two planes’ relative pose. 3-P̲SP parallel module is typical architecture which has been widely investigated in recent researches. In this paper, the direct-inverse position problems of the 3-P̲SP parallel module in the couple mixed-type mode are analyzed in detail, and the solutions are obtained in an analytical form. Furthermore, the solutions for the direct and inverse position problems of the novel hybrid serial-parallel mechanism are also derived and obtained in the analytical form. The proposed hybrid serial-parallel mechanism is applied to regulate the immersion hood’s pose in an immersion lithography system. Through measuring and regulating the pose of the immersion hood with respect to the wafer surface simultaneously, the immersion hood can track the wafer surface’s pose in real-time and the gap status is stabilized. This is another exploration to hybrid serial-parallel mechanism’s application.

  6. Motor cortical encoding of serial order in a context-recall task.

    Science.gov (United States)

    Carpenter, A F; Georgopoulos, A P; Pellizzer, G

    1999-03-12

    The neural encoding of serial order was studied in the motor cortex of monkeys performing a context-recall memory scanning task. Up to five visual stimuli were presented successively on a circle (list presentation phase), and then one of them (test stimulus) changed color; the monkeys had to make a single motor response toward the stimulus that immediately followed the test stimulus in the list. Correct performance in this task depends on memorization of the serial order of the stimuli during their presentation. It was found that changes in neural activity during the list presentation phase reflected the serial order of the stimuli; the effect on cell activity of the serial order of stimuli during their presentation was at least as strong as the effect of motor direction on cell activity during the execution of the motor response. This establishes the serial order of stimuli in a motor task as an important determinant of motor cortical activity during stimulus presentation and in the absence of changes in peripheral motor events, in contrast to the commonly held view of the motor cortex as just an "upper motor neuron."

  7. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  8. Reaction kinetics in open reactors and serial transfers between closed reactors

    Science.gov (United States)

    Blokhuis, Alex; Lacoste, David; Gaspard, Pierre

    2018-04-01

    Kinetic theory and thermodynamics of reaction networks are extended to the out-of-equilibrium dynamics of continuous-flow stirred tank reactors (CSTR) and serial transfers. On the basis of their stoichiometry matrix, the conservation laws and the cycles of the network are determined for both dynamics. It is shown that the CSTR and serial transfer dynamics are equivalent in the limit where the time interval between the transfers tends to zero proportionally to the ratio of the fractions of fresh to transferred solutions. These results are illustrated with a finite cross-catalytic reaction network and an infinite reaction network describing mass exchange between polymers. Serial transfer dynamics is typically used in molecular evolution experiments in the context of research on the origins of life. The present study is shedding a new light on the role played by serial transfer parameters in these experiments.

  9. The effects of nidopallium caudolaterale inactivation on serial-order behaviour in pigeons (Columba livia).

    Science.gov (United States)

    Johnston, Melissa Jane; Clarkson, Andrew N; Gowing, Emma K; Scarf, Damian; Colombo, Mike

    2018-06-06

    Serial-order behaviour is the ability to complete a sequence of responses in a predetermined order to achieve a reward. In birds, serial-order behaviour is thought to be impaired by damage to the nidopallium caudolaterale (NCL). In the current study, we examined the role of the NCL in serial-order behaviour by training pigeons on a 4-item serial-order task and a go/no-go discrimination task. Following training, pigeons were received infusions of 1μl of either tetrodotoxin (TTX) or saline. Saline infusions had no impact on serial-order behaviour whereas TTX infusions resulted in a significant decrease in performance. The serial-order impairments, however, were not the results of errors of any specific error at any specific list item. With respect to the go/no-go discrimination task, saline infusions also had no impact on performance whereas TTX infusions impaired pigeons' discrimination abilities. Given the impairments on the go/no-go discrimination task, which does not require processing of serial-order information, we tentatively conclude that damage to the NCL does not impair serial-order behaviour per se, but rather results in a more generalised impairment that may impact performance across a range of tasks.

  10. Some Considerations on Seriality and Synchronicity

    Directory of Open Access Journals (Sweden)

    Elena Nechita

    2010-01-01

    Full Text Available This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  11. Serum copper and zinc concentrations in a representative sample of the Canarian population.

    Science.gov (United States)

    Díaz Romero, Carlos; Henríquez Sánchez, Patricia; López Blanco, Félix; Rodríguez Rodríguez, Elena; Serra Majem, Lluis

    2002-01-01

    Serum copper (Cu) and zinc (Zn) concentrations of 395 individuals (187 males + 208 females) living in Canary Islands were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 1.10 +/- 0.25 mg/L and 1.16 +/- 0.52 mg/L respectively. Our data were similar to other data published in other Spanish regions. Individuals from Lanzarote presented a mean Cu and Zn concentrations higher (p EL Hierro showed the lowest (p 0.05) among the different age intervals. No clear trends in the serum Cu and Zn concentrations were observed when drinking and smoking habits were considered. The increase of physical exercise reduced (p < 0.05) the serum Cu concentrations.

  12. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    International Nuclear Information System (INIS)

    Fliniaux, Ophélie; Gaillard, Gwenaelle; Lion, Antoine; Cailleu, Dominique; Mesnard, François; Betsou, Fotini

    2011-01-01

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4°C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4°C. Five or ten serum freeze–thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  13. Sensitivity and specificity of parallel or serial serological testing for detection of canine Leishmania infection

    Directory of Open Access Journals (Sweden)

    Mauro Maciel de Arruda

    2016-01-01

    Full Text Available In Brazil, human and canine visceral leishmaniasis (CVL caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA and indirect immunofluorescence assays (IFA as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA, decreased sensitivity (83.3% and increased specificity (92.5% were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

  14. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  15. Serum cytokine levels in Kleine-Levin syndrome

    DEFF Research Database (Denmark)

    Kornum, Birgitte Rahbek; Rico, Thomas; Lin, Ling

    2015-01-01

    in USA, France, and Taiwan in a clinical setting. Processing of the samples was performed at the Stanford Center for Sleep Sciences and Medicine. RESULTS: We did not observe any changes in serum cytokine levels during KLS episodes compared to between episodes. In a small cohort of asymptomatic KLS...... patients and age- and gender matched healthy controls (n = 8/group) whose blood samples were all collected and processed at the same day; asymptomatic KLS patients had significantly higher levels of serum sVCAM1 cytokine compared to healthy controls. CONCLUSION: These data suggest that KLS episodes...... unknown. The objective of this study was to determine serum cytokine levels in patients with KLS during and between episodes. PATIENTS/METHODS: Fifty-two typical KLS patients were included in the study of whom 17 patients donated blood samples both during and between episodes. Blood samples were collected...

  16. Se-SAD serial femtosecond crystallography datasets from selenobiotinyl-streptavidin

    Science.gov (United States)

    Yoon, Chun Hong; Demirci, Hasan; Sierra, Raymond G.; Dao, E. Han; Ahmadi, Radman; Aksit, Fulya; Aquila, Andrew L.; Batyuk, Alexander; Ciftci, Halilibrahim; Guillet, Serge; Hayes, Matt J.; Hayes, Brandon; Lane, Thomas J.; Liang, Meng; Lundström, Ulf; Koglin, Jason E.; Mgbam, Paul; Rao, Yashas; Rendahl, Theodore; Rodriguez, Evan; Zhang, Lindsey; Wakatsuki, Soichi; Boutet, Sébastien; Holton, James M.; Hunter, Mark S.

    2017-04-01

    We provide a detailed description of selenobiotinyl-streptavidin (Se-B SA) co-crystal datasets recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS) for selenium single-wavelength anomalous diffraction (Se-SAD) structure determination. Se-B SA was chosen as the model system for its high affinity between biotin and streptavidin where the sulfur atom in the biotin molecule (C10H16N2O3S) is substituted with selenium. The dataset was collected at three different transmissions (100, 50, and 10%) using a serial sample chamber setup which allows for two sample chambers, a front chamber and a back chamber, to operate simultaneously. Diffraction patterns from Se-B SA were recorded to a resolution of 1.9 Å. The dataset is publicly available through the Coherent X-ray Imaging Data Bank (CXIDB) and also on LCLS compute nodes as a resource for research and algorithm development.

  17. [Personality disorders, psychopathy and serial killers].

    Science.gov (United States)

    Morana, Hilda C P; Stone, Michael H; Abdalla-Filho, Elias

    2006-10-01

    To illustrate the basic characteristics of several specific personality disorders, focusing mainly in antisocial personality disorder. The differences between antisocial personality disorder and psychopathy are highlighted. Serial killers and its psychopathic aspects are also discussed. A bibliographic review was completed in order to outline convergences and divergences among different authors about this controversial issue, especially those concerning the possibility of treatment. While anti-social personality disorder is a medical diagnosis, the term "psychopathy" (which belongs to the sphere of forensic psychiatry) may be understood as a "legal diagnosis". It is not still possible to identify an effective treatment for serial killers. Personality disorders, especially of the antisocial type, still represent a formidable challenge to forensic psychiatry today. Questions as yet unanswered include the best and most humane place for patients with this condition and the nature of a standardised treatment recommendation.

  18. How Do We Write about Performance in Serial Television?

    OpenAIRE

    Elliott Logan

    2015-01-01

    Television studies has produced few sustained analyses of performance in serial television. Yet film studies scholarship has shown how attending to the integration of performances with other aspects of film style is crucial to the interpretation and appreciation of expression and meaning in filmed narrative fictions. However, as a particle form of filmed serial narrative, series television raises a number of questions about performance that will not necessarily be satisfyingly addressed by th...

  19. Association between absolute tumor burden and serum bone-specific alkaline phosphatase in canine appendicular osteosarcoma.

    Science.gov (United States)

    Sternberg, R A; Pondenis, H C; Yang, X; Mitchell, M A; O'Brien, R T; Garrett, L D; Helferich, W G; Hoffmann, W E; Fan, T M

    2013-01-01

    In dogs with appendicular osteosarcoma (OSA), increased pretreatment serum bone-specific alkaline phosphatase (BALP) activity is a negative prognostic factor, associated with shorter disease-free intervals and survival times, but a biologic basis for observed differential serum BALP activities in canine OSA patients remains incompletely defined. Serum BALP activity will correlate with absolute tumor burden in dogs with OSA. This study included 96 client-owned dogs with appendicular OSA. In canine OSA cell lines, the expression and membranous release of BALP was evaluated in vitro. The correlation between serum BALP activity and radiographic primary tumor size was evaluated in OSA-bearing dogs. In dogs developing visceral OSA metastases, serial changes in serum BALP activities were evaluated in relation to progression of macroscopic metastases, and visceral metastatic OSA cells were evaluated for BALP expression. In vitro, BALP expression was not associated with either tumorigenic or metastatic phenotype, rather the quantity of membranous BALP released was proportional with cell density. In dogs devoid of macroscopic metastases, there was a positive correlation between serum BALP activity and absolute primary tumor size. In dogs with progressive OSA metastases, serum BALP activity increased and coincided with the development of macroscopic metastases. OSA cells derived from visceral metastatic lesions retained BALP expression. Tumor burden is a determinant of serum BALP activity in dogs with appendicular OSA. The association between increased pretreatment BALP activity and negative clinical prognosis may simply be attributed to greater initial tumor burden, and consequently more advanced tumor stage. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  20. Serial cranial ultrasonography or early MRI for detecting preterm brain injury?

    NARCIS (Netherlands)

    Plaisier, Annemarie; Raets, Marlou M A; Ecury-Goossen, Ginette M; Govaert, Paul; Feijen-Roon, Monique; Reiss, Irwin K M; Smit, Liesbeth S; Lequin, Maarten H; Dudink, Jeroen

    OBJECTIVE: To investigate detection ability and feasibility of serial cranial ultrasonography (CUS) and early MRI in preterm brain injury. DESIGN: Prospective cohort study. SETTING: Level III neonatal intensive care unit. PATIENTS: 307 infants, born below 29 weeks of gestation. METHODS: Serial CUS

  1. Paths to destruction: the lives and crimes of two serial killers.

    Science.gov (United States)

    Wolf, Barbara C; Lavezzi, Wendy A

    2007-01-01

    Although research into the phenomenon of serial murder has revealed that serial killers frequently do not fit the initially described paradigm in terms of their physical and psychological profiles, backgrounds, and motives to kill, the media continues to sensationalize the figures of such killers and the investigators who attempt to analyze them on the basis of aspects of their crimes. Although the so-called "typical" profile of the serial murderer has proven accurate in some instances, in many other cases the demographics and behaviors of these killers have deviated widely from the generalized assumptions. This report details two unusual cases in which five and eight murders were committed in upstate New York. The lives and crimes of these offenders illustrate the wide spectrum of variations in the backgrounds, demographics, motivations, and actions witnessed among serial murderers, and highlight the limitations and dangers of profiling based on generalities.

  2. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  3. Serial changes in selected serum constituents in low birth weight infants on peripheral parenteral nutrition with different zinc and copper supplements.

    Science.gov (United States)

    Lockitch, G; Pendray, M R; Godolphin, W J; Quigley, G

    1985-07-01

    One hundred and five infants of birth weight 2000 g or less who received peripherally administered parenteral nutrition for periods of three or more weeks, were randomly assigned to groups receiving different amounts of zinc and copper supplement. The blood concentrations of zinc, copper, retinol-binding protein, prealbumin, alkaline phosphatase and aspartate transaminase were followed weekly. Mean serum zinc, retinol-binding protein and prealbumin declined significantly over time while alkaline phosphatase rose. Only the group receiving the highest zinc supplement maintained a mean serum zinc concentration within the normal range at seven weeks. No difference in the protein or enzyme concentrations was found between the different zinc supplement groups. No difference was seen in serum copper or ceruloplasmin between copper dose groups although one intravenous supplement was double that of the other.

  4. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Fliniaux, Ophelie [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Gaillard, Gwenaelle [Biobanque de Picardie (France); Lion, Antoine [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Cailleu, Dominique [Batiment Serres-Transfert, rue de Mai/rue Dallery, Plateforme Analytique (France); Mesnard, Francois, E-mail: francois.mesnard@u-picardie.fr [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Betsou, Fotini [Integrated Biobank of Luxembourg (Luxembourg)

    2011-12-15

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4 Degree-Sign C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4 Degree-Sign C. Five or ten serum freeze-thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  5. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  6. New developments in electron microscopy for serial image acquisition of neuronal profiles.

    Science.gov (United States)

    Kubota, Yoshiyuki

    2015-02-01

    Recent developments in electron microscopy largely automate the continuous acquisition of serial electron micrographs (EMGs), previously achieved by laborious manual serial ultrathin sectioning using an ultramicrotome and ultrastructural image capture process with transmission electron microscopy. The new systems cut thin sections and capture serial EMGs automatically, allowing for acquisition of large data sets in a reasonably short time. The new methods are focused ion beam/scanning electron microscopy, ultramicrotome/serial block-face scanning electron microscopy, automated tape-collection ultramicrotome/scanning electron microscopy and transmission electron microscope camera array. In this review, their positive and negative aspects are discussed. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Rehearsal in serial memory for visual-spatial information: evidence from eye movements.

    Science.gov (United States)

    Tremblay, Sébastien; Saint-Aubin, Jean; Jalbert, Annie

    2006-06-01

    It is well established that rote rehearsal plays a key role in serial memory for lists of verbal items. Although a great deal of research has informed us about the nature of verbal rehearsal, much less attention has been devoted to rehearsal in serial memory for visual-spatial information. By using the dot task--a visual-spatial analogue of the classical verbal serial recall task--with delayed recall, performance and eyetracking data were recorded in order to establish whether visual-spatial rehearsal could be evidenced by eye movement. The use of eye movement as a form of rehearsal is detectable (Experiment 1), and it seems to contribute to serial memory performance over and above rehearsal based on shifts of spatial attention (Experiments 1 and 2).

  8. SMALL SERIAL AND SERIAL PRODUCTION MANAGEMENT IN UNSTABLE DEMAND ENVIROUMENT

    Directory of Open Access Journals (Sweden)

    Tsomaeva I. V.

    2014-03-01

    Full Text Available The work presents the methodological approach to production program of the enterprise serial engineering for the current period in the conditions of uncertainty of demand. Here are two problems with this. The first is connected with the formation of the production program of the next quarter, year. Objective could be to stochastic programming, but this task is difficult. Therefore, in this paper we proposed a simple solution. On the basis of statistical historical information about the deviation of actual sales data products from predicted by Monte Carlo generated a lot of production programs. Fixed worst key performance (sales, profit etc. The difference between the values of the planned target and the settlement defines stochastic reserve, to be established at the expense of additional innovations. The second problem is connected with the formation of the production program production in the planned month, taking into account the creation of stocks of production in the conditions when for a short period of time is difficult to build a pattern of change in the quantity demanded by month for serial production, as in some months of the year the products are not produced nor sold. To justify the level of inventories of finished products is information on deviations from the fact plan for past periods. Built function of frequency distribution of the values of deviations. This allows you to further build the methodology for determining the level of production (taking into account the reserves and sales of products that deliver maximum economic effect from the sales in the conditions of a random process of realization of production.

  9. DDCMP protocol on a DMA serial-line board

    International Nuclear Information System (INIS)

    Hunt, D.N.; Kessler, G.C.

    1982-01-01

    The Nuclear Chemistry Division of Lawrence Livermore National Laboratory is in the midst of an upgrade to their radiation counting facility. The result of this upgrade wil be a computer-based data acquisition network, the Nuclear Chemistry Counting Facility Network (NCCF-NET). This network will consist of forty dedicated LSI-11/2 based controllers, ten interactive LSI-11/23 based workstations and a VAX-11/750 central node for data reduction and storage. One of the data acquisition instruments used in this network is a Nuclear Data pulse-height analyzer, the ND66L. This analyzer communicates to a host system over a 9600-baud serial line, using the DDCMP link level protocol. In order to relieve the host computer from the overhead of handling the DDCMP protocol, an in-house designed DMA serial line board was implemented to communicate with the ND66L. The hardware used and its environment will be duscussed along with the design and implementation of the firmware, which implements the serial DDCMP link

  10. A network-based Macintosh serial host interface program

    International Nuclear Information System (INIS)

    Wight, J.

    1991-03-01

    A program has been written for the Apple Macintosh to replace conventional host RS232 terminals with customizable user interfaces. Serial port NuBus cards in the Macintosh allow many simultaneous sessions to be maintained. A powerful system is attained by connecting multiple Macintoshes on a network, each running this program. Each is then able to share incoming data from any of its serial ports with any other Macintosh, as well as accept data from any other Macintosh for output to any of its serial ports. The program has been used to eliminate multiple host terminals, modernize the user interface, and to centralize operation of a complex control system. Minimal changes to host software have been required. By making extensive use of Macintosh resources, the same executable code serves in a variety of roles. An object oriented C language with a class library made the development straightforward and easy to modify. This program is used to control a 2 MW neutral beam system on the DIII-D magnetic fusion tokamak. 7 figs

  11. Serial casting for reconstruction of a deformed Charcot foot: a case report.

    Science.gov (United States)

    Rosenblum, Jonathan I; Weiss, Shmuel; Gazes, Michael; Amit-Kohn, Michal

    2015-05-01

    Charcot neuroarthropathy may occur in patients with peripheral neuropathy who do not notice pain while their bones and joints collapse or breakdown under the constant pressure of body weight. This can lead to ulcerations from severe deformity and potentially limb-threatening and life-threatening infections. Current treatments vary from immobilization to extensive reconstructive surgical interventions. Serial casting, used to correct many pediatric deformities while bones are often more pliable, was used with a 63-year-old male patient who presented with an active phase of Charcot foot with ulceration. The patient previously underwent foot reconstruction and had all hardware removed prior to serial casting. Due to the potential pliability of the bones, serial casting was attempted to reform the shape and position of the foot in a reverse Ponseti-type serial casting to create a more stable structure with less deformity that could lead to epithelial breakdown. The patient regained full ambulation with a plantargrade foot and no wounds, and was followed without complications for 36 months. Serial weekly casting was an effective modality for treatment of this patient's Charcot foot deformity.

  12. The utilization of forensic science and criminal profiling for capturing serial killers.

    Science.gov (United States)

    White, John H; Lester, David; Gentile, Matthew; Rosenbleeth, Juliana

    2011-06-15

    Movies and nightly television shows appear to emphasize highly efficient regimens in forensic science and criminal investigative analysis (profiling) that result in capturing serial killers and other perpetrators of homicide. Although some of the shows are apocryphal and unrealistic, they reflect major advancements that have been made in the fields of forensic science and criminal psychology during the past two decades that have helped police capture serial killers. Some of the advancements are outlined in this paper. In a study of 200 serial killers, we examined the variables that led to police focusing their attention on specific suspects. We developed 12 categories that describe how serial killers come to the attention of the police. The results of the present study indicate that most serial killers are captured as a result of citizens and surviving victims contributing information that resulted in police investigations that led to an arrest. The role of forensic science appears to be important in convicting the perpetrator, but not necessarily in identifying the perpetrator. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Spatial patterns of serial murder: an analysis of disposal site location choice.

    Science.gov (United States)

    Lundrigan, S; Canter, D

    2001-01-01

    Although the murders committed by serial killers may not be considered rational, there is growing evidence that the locations in which they commit their crimes may be guided by an implicit, if limited rationality. The hypothesized logic of disposal site choice of serial killers led to predictions that (a) their criminal domains would be around their home base and relate to familiar travel distances, (b) they would have a size that was characteristic of each offender, (c) the distribution would be biased towards other non-criminal activities, and (d) the size of the domains would increase over time. Examination of the geographical distribution of the sites at which 126 US and 29 UK serial killers disposed of their victims' bodies supported all four hypotheses. It was found that rational choice and routine activity models of criminal behavior could explain the spatial choices of serial murderers. It was concluded that the locations at which serial killers dispose of their victims' bodies reflect the inherent logic of the choices that underlie their predatory activities. Copyright 2001 John Wiley & Sons, Ltd.

  14. Assessing Working Memory in Mild Cognitive Impairment with Serial Order Recall.

    Science.gov (United States)

    Emrani, Sheina; Libon, David J; Lamar, Melissa; Price, Catherine C; Jefferson, Angela L; Gifford, Katherine A; Hohman, Timothy J; Nation, Daniel A; Delano-Wood, Lisa; Jak, Amy; Bangen, Katherine J; Bondi, Mark W; Brickman, Adam M; Manly, Jennifer; Swenson, Rodney; Au, Rhoda

    2018-01-01

    Working memory (WM) is often assessed with serial order tests such as repeating digits backward. In prior dementia research using the Backward Digit Span Test (BDT), only aggregate test performance was examined. The current research tallied primacy/recency effects, out-of-sequence transposition errors, perseverations, and omissions to assess WM deficits in patients with mild cognitive impairment (MCI). Memory clinic patients (n = 66) were classified into three groups: single domain amnestic MCI (aMCI), combined mixed domain/dysexecutive MCI (mixed/dys MCI), and non-MCI where patients did not meet criteria for MCI. Serial order/WM ability was assessed by asking participants to repeat 7 trials of five digits backwards. Serial order position accuracy, transposition errors, perseverations, and omission errors were tallied. A 3 (group)×5 (serial position) repeated measures ANOVA yielded a significant group×trial interaction. Follow-up analyses found attenuation of the recency effect for mixed/dys MCI patients. Mixed/dys MCI patients scored lower than non-MCI patients for serial position 3 (p Mixed/dys MCI patients also produced more transposition errors than both groups (p order parameters obtained from the BDT may provide a useful operational definition as well as additional diagnostic information regarding working memory deficits in MCI.

  15. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  16. A serial-kinematic nanopositioner for high-speed atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wadikhaye, Sachin P., E-mail: sachin.wadikhaye@uon.edu.au; Yong, Yuen Kuan; Reza Moheimani, S. O. [School of Electrical Engineering and Computer Science, The University of Newcastle, Callaghan, NSW (Australia)

    2014-10-15

    A flexure-guided serial-kinematic XYZ nanopositioner for high-speed Atomic Force Microscopy is presented in this paper. Two aspects influencing the performance of serial-kinematic nanopositioners are studied in this work. First, mass reduction by using tapered flexures is proposed to increased the natural frequency of the nanopositioner. 25% increase in the natural frequency is achieved due to reduced mass with tapered flexures. Second, a study of possible sensor positioning in a serial-kinematic nanopositioner is presented. An arrangement of sensors for exact estimation of cross-coupling is incorporated in the proposed design. A feedforward control strategy based on phaser approach is presented to mitigate the dynamics and nonlinearity in the system. Limitations in design approach and control strategy are discussed in the Conclusion.

  17. A serial-kinematic nanopositioner for high-speed atomic force microscopy

    International Nuclear Information System (INIS)

    Wadikhaye, Sachin P.; Yong, Yuen Kuan; Reza Moheimani, S. O.

    2014-01-01

    A flexure-guided serial-kinematic XYZ nanopositioner for high-speed Atomic Force Microscopy is presented in this paper. Two aspects influencing the performance of serial-kinematic nanopositioners are studied in this work. First, mass reduction by using tapered flexures is proposed to increased the natural frequency of the nanopositioner. 25% increase in the natural frequency is achieved due to reduced mass with tapered flexures. Second, a study of possible sensor positioning in a serial-kinematic nanopositioner is presented. An arrangement of sensors for exact estimation of cross-coupling is incorporated in the proposed design. A feedforward control strategy based on phaser approach is presented to mitigate the dynamics and nonlinearity in the system. Limitations in design approach and control strategy are discussed in the Conclusion

  18. Serial CT scans and MRI scans of Tay-Sachs disease

    International Nuclear Information System (INIS)

    Shimoizumi, Hideo; Miyao, Masutomo; Ichihashi, Koh; Sawa, Rituko; Yamamoto, Yoshifumi; Tanaka, Osamu; Yanagisawa, Masayoshi; Kamoshita, Shigehiko.

    1986-01-01

    Serial X-ray CT and MRI were performed on 2 cases of Tay-Sachs disease. Case 1 : a 3-year-10-month-old girl. Her developmental milestones were normal until the age of 6 months. At the age of 10 months, hypotonia and unduly sensitiveness to sounds were noticed. She had cherry red spots in both fundi, and the serum hexosaminidase A activity was low. Significant clinical features during the next 3 years included regression of developmental milestones to the level of one month, and myoclonic and generalised seizures. After 3 years she showed megalencephaly, unstable body temperature, and respiratory disorders. Case 2 : a 2-year-6-month-old boy. His developmental milestones were normal until the age of 5 months. Then he manifested hyperreaction to noises and further developments ceased. He started to deteriorate from the age of 1 year and 2 months, and had no head control at the age of 1 year and 6 months. Cherry red spots were detected and the serum hexsosaminidase A activity was low, too. X-ray CT at the early stage of cases 1 and 2 showed mild cerebral atrophy and high density areas in bilateral thalami and basal ganglia. At the late stage of Case 1, high density areas appeared in occipital and frontal white matters. MRI in both patients were strikingly similar. In their grey matters, linear light areas were demonstrated on IR images. Their white matters showed extensive dark (long T 1 ) areas on IR images, and extensive light (long T 2 ) areas on SE images. Bilateral thalami and basal ganglia were light on IR images and dark on SE images. The findings of MRI in our patients seemed to correlate well with pathological and biochemical changes in their brains. (author)

  19. Serial Millisecond Crystallography of Membrane Proteins.

    Science.gov (United States)

    Jaeger, Kathrin; Dworkowski, Florian; Nogly, Przemyslaw; Milne, Christopher; Wang, Meitian; Standfuss, Joerg

    2016-01-01

    Serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) is a powerful method to determine high-resolution structures of pharmaceutically relevant membrane proteins. Recently, the technology has been adapted to carry out serial millisecond crystallography (SMX) at synchrotron sources, where beamtime is more abundant. In an injector-based approach, crystals grown in lipidic cubic phase (LCP) or embedded in viscous medium are delivered directly into the unattenuated beam of a microfocus beamline. Pilot experiments show the application of microjet-based SMX for solving the structure of a membrane protein and compatibility of the method with de novo phasing. Planned synchrotron upgrades, faster detectors and software developments will go hand-in-hand with developments at free-electron lasers to provide a powerful methodology for solving structures from microcrystals at room temperature, ligand screening or crystal optimization for time-resolved studies with minimal or no radiation damage.

  20. Quantitative polymerase chain reaction detection of circulating DNA in serum for early diagnosis of mucormycosis in immunocompromised patients.

    Science.gov (United States)

    Millon, Laurence; Larosa, Fabrice; Lepiller, Quentin; Legrand, Faezeh; Rocchi, Steffi; Daguindau, Etienne; Scherer, Emeline; Bellanger, Anne-Pauline; Leroy, Joel; Grenouillet, Frederic

    2013-05-01

    The aim of our study was to assess the detection of circulating DNA from the most common species of Mucorales for early diagnosis of mucormycosis in at-risk patients. We retrospectively evaluated a combination of 3 quantitative polymerase chain reaction (qPCR) assays using hydrolysis probes targeting Mucor/Rhizopus, Lichtheimia (formerly Absidia), and Rhizomucor for circulating Mucorales detection. Serial serum samples from 10 patients diagnosed with proven mucormycosis (2-9 samples per patient) were analyzed. No cross-reactivity was detected in the 3 qPCR assays using 19 reference strains of opportunistic fungi, and the limit of detection ranged from 3.7 to 15 femtograms/10 µL, depending on the species. DNA from Mucorales was detected in the serum of 9 of 10 patients between 68 and 3 days before mucormycosis diagnosis was confirmed by histopathological examination and/or positive culture. All the qPCR results were concordant with culture and/or PCR-based identification of the causing agents in tissue (Lichtheimia species, Rhizomucor species, and Mucor/Rhizopus species in 4, 3, and 2 patients, respectively). Quantitative PCR was negative in only 1 patient with proven disseminated mucormycosis caused by Lichtheimia species. Our study suggests that using specific qPCR targeting several species of Mucorales according to local ecology to screen at-risk patients could be useful in a clinical setting. The cost and efficacy of this strategy should be evaluated. However, given the human and economic cost of mucormycosis and the need for rapid diagnosis to initiate prompt directed antifungal therapy, this strategy could be highly attractive.

  1. Serum thyroglobulin in normal subjects and patients with hyperthyroidism due to Graves' disease: effects of T3, iodide, 131I and antithyroid drugs

    International Nuclear Information System (INIS)

    Gardner, D.F.; Rothman, J.; Utiger, R.D.

    1979-01-01

    A sensitive, reproducible radioimmunoassay for thyroglobulin (Tg) in unextracted human serum is described. The mean (+SD) serum thyroglobulin concentration in ninety-three normal subjects was 8.8 +- 5.1 ng/ml. The mean serum concentration in forty-seven patients with hyperthyroidism due to Graves' disease was 162 +- 145 ng/ml, and in nine patients with subacute thyroiditis 140 +- 75 ng/ml. In normal subjects, the effects of T3 and inorganic iodide on the levels of serum Tg and T4 were measured. In hyperthyroid (Graves' disease) patients, the effects of iodide, radioactive iodine and antithyroid drugs on serum Tg, T3 and T4 levels were measured. The data suggested that; (1) Tg release by the thyroid is normally under TSH control; (2) iodide inhibits thyroidal T4 and T3 release without affecting Tg secretion; (3) thyroidal injury results in marked increases in serum Tg concentrations; and (4) initial and/or serial Tg determinations may be useful in predicting remission in patients with hyperthyroidism due to Graves' disease treated with antithyroid drugs. (author)

  2. Serial-position effects on a free-recall task in bilinguals.

    Science.gov (United States)

    Yoo, Jeewon; Kaushanskaya, Margarita

    2016-01-01

    In this study, we examined mechanisms that underlie free-recall performance in bilinguals' first language (L1) and second language (L2) through the prism of serial-position effects. On free-recall tasks, a typical pattern of performance follows a U-shaped serial-position curve, where items from the beginning of the list (the primacy effect) and items from the end of the list (the recency effect) are recalled with higher accuracy than items from the middle of the list. The present study contrasted serial-position effects on the free-recall task in Korean-English bilinguals' L1 vs. L2 and examined the relationship between an independent working memory (WM) measure and serial-position effects in bilinguals' two languages. Results revealed stronger pre-recency (primacy and middle) effects in L1 than in L2, but similar recency effects in the two languages. A close association was observed between WM and recall performance in the pre-recency region in the L1 but not in the L2. Together, these findings suggest that linguistic knowledge constrains free-recall performance in bilinguals, but only in the pre-recency region.

  3. A study on the utilization of serial resources in selected tertiary ...

    African Journals Online (AJOL)

    A study on the utilization of serial resources in selected tertiary institutions in Ogun State. ... Lagos Journal of Library and Information Science ... Serial resources are publications either in printed form or electronic format issued in successive parts usually having numerical or chronological designations and intended to be ...

  4. Modelling and Forecasting Stock Price Movements with Serially Dependent Determinants

    Directory of Open Access Journals (Sweden)

    Rasika Yatigammana

    2018-05-01

    Full Text Available The direction of price movements are analysed under an ordered probit framework, recognising the importance of accounting for discreteness in price changes. By extending the work of Hausman et al. (1972 and Yang and Parwada (2012,This paper focuses on improving the forecast performance of the model while infusing a more practical perspective by enhancing flexibility. This is achieved by extending the existing framework to generate short term multi period ahead forecasts for better decision making, whilst considering the serial dependence structure. This approach enhances the flexibility and adaptability of the model to future price changes, particularly targeting risk minimisation. Empirical evidence is provided, based on seven stocks listed on the Australian Securities Exchange (ASX. The prediction success varies between 78 and 91 per cent for in-sample and out-of-sample forecasts for both the short term and long term.

  5. Quantitative determination of albumin in microlitre amounts of rat serum: With a short note on serum albumin levels in ageing rats

    NARCIS (Netherlands)

    Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.; Hollander, C.F.

    1967-01-01

    A simple dye binding method for determining rat serum albumin, which employs the anionic dye 2-(4′-hydroxybenzneeazo) benzoic acid (HBABA) is described. Albumin in 5μ1 of serum is determined colorimetrically. Purified rat albumin is used as a primary standard and rat serum as a reference sample.

  6. Subject-Verb Agreement in Children and Adults: Serial or Hierarchical Processing?

    Science.gov (United States)

    Negro, Isabelle; Chanquoy, Lucile; Fayol, Michel; Louis-Sidney, Maryse

    2005-01-01

    Two processes, serial and hierarchical, are generally opposed to account for grammatical encoding in language production. In a developmental perspective, the question addressed here is whether the subject-verb agreement during writing is computed serially, once the words are linearly ordered in the sentence, or hierarchically, as soon as the…

  7. Serial Position Effects in the Identification of Letters, Digits, and Symbols

    Science.gov (United States)

    Tydgat, Ilse; Grainger, Jonathan

    2009-01-01

    In 6 experiments, the authors investigated the form of serial position functions for identification of letters, digits, and symbols presented in strings. The results replicated findings obtained with the target search paradigm, showing an interaction between the effects of serial position and type of stimulus, with symbols generating a distinct…

  8. Efficient multitasking: parallel versus serial processing of multiple tasks.

    Science.gov (United States)

    Fischer, Rico; Plessow, Franziska

    2015-01-01

    In the context of performance optimizations in multitasking, a central debate has unfolded in multitasking research around whether cognitive processes related to different tasks proceed only sequentially (one at a time), or can operate in parallel (simultaneously). This review features a discussion of theoretical considerations and empirical evidence regarding parallel versus serial task processing in multitasking. In addition, we highlight how methodological differences and theoretical conceptions determine the extent to which parallel processing in multitasking can be detected, to guide their employment in future research. Parallel and serial processing of multiple tasks are not mutually exclusive. Therefore, questions focusing exclusively on either task-processing mode are too simplified. We review empirical evidence and demonstrate that shifting between more parallel and more serial task processing critically depends on the conditions under which multiple tasks are performed. We conclude that efficient multitasking is reflected by the ability of individuals to adjust multitasking performance to environmental demands by flexibly shifting between different processing strategies of multiple task-component scheduling.

  9. The neural signature of emotional memories in serial crimes.

    Science.gov (United States)

    Chassy, Philippe

    2017-10-01

    Neural plasticity is the process whereby semantic information and emotional responses are stored in neural networks. It is hypothesized that the neural networks built over time to encode the sexual fantasies that motivate serial killers to act should display a unique, detectable activation pattern. The pathological neural watermark hypothesis posits that such networks comprise activation of brain sites that reflect four cognitive components: autobiographical memory, sexual arousal, aggression, and control over aggression. The neural sites performing these cognitive functions have been successfully identified by previous research. The key findings are reviewed to hypothesise the typical pattern of activity that serial killers should display. Through the integration of biological findings into one framework, the neural approach proposed in this paper is in stark contrast with the many theories accounting for serial killers that offer non-medical taxonomies. The pathological neural watermark hypothesis offers a new framework to understand and detect deviant individuals. The technical and legal issues are briefly discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Quantitating Iron in Serum Ferritin by Use of ICP-MS

    Science.gov (United States)

    Smith, Scott M.; Gillman, Patricia L.

    2003-01-01

    A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid

  11. Changing Series: Narrative Models and the Role of the Viewer in Contemporary Television Seriality

    Directory of Open Access Journals (Sweden)

    Veronica Innocenti

    2015-04-01

    Full Text Available In the past few years television serial narratives have gone through some severe changes in the way they are organized from a narrative point of view, as well as in the way they are perceived by the audiences. Our article originates from the necessity of investigating the products of this new wave of serial production, with the purpose of focusing on narrative formulas and on the relationships that serial products establish with their users. Vast serialized narratives are not just texts anymore, they have become complex universes of meaning that last for long time and that have a strong influence on the audiences. The article aims to investigate serial narratives as usable objects, that are not just seen by the public, but that are part of a complex experience.

  12. Alcohol purchase age laws and the serial beginning drinker in New York.

    Science.gov (United States)

    Yu, J

    1995-08-01

    Raising the drinking age twice in New York State in the 1980s might have created a generation of "serial beginning drinkers." Findings indicate that when young adults become beginning drinkers, their chances of drinking-driving increase; when they become serial beginning drinkers, their involvement in drinking-driving remains high over time. The beginning drinkers belong to a special historical period and are only composed of birth cohorts of 3 or 4 years (mainly early 1960s). The effect of the serial beginning drinker should fade out as those birth cohorts grow into maturity.

  13. Synchronic Seriality: The Dissolving of Diegetic Borders Through Metalepsis

    Directory of Open Access Journals (Sweden)

    Paige M. Piper

    2015-12-01

    Full Text Available In dialogue with Gérard Genette’s literary concept of metalepsis to television, this paper considers instances of meta-textual actor/character portrayals in serial narratives to show that meta-narrative intrusion fosters a greater empathetic link between the spectator and character, whilst simultaneously inviting the viewer to appreciate the technique as an artifice-aware gesture. The fluidity of diegetic borders brought on by the conflation of performer/performance replicates Baudrillard’s simulacra, creating a synchronic form of seriality and transcending rigid genre classifications.

  14. Spatial serial order processing in schizophrenia.

    Science.gov (United States)

    Fraser, David; Park, Sohee; Clark, Gina; Yohanna, Daniel; Houk, James C

    2004-10-01

    The aim of this study was to examine serial order processing deficits in 21 schizophrenia patients and 16 age- and education-matched healthy controls. In a spatial serial order working memory task, one to four spatial targets were presented in a randomized sequence. Subjects were required to remember the locations and the order in which the targets were presented. Patients showed a marked deficit in ability to remember the sequences compared with controls. Increasing the number of targets within a sequence resulted in poorer memory performance for both control and schizophrenia subjects, but the effect was much more pronounced in the patients. Targets presented at the end of a long sequence were more vulnerable to memory error in schizophrenia patients. Performance deficits were not attributable to motor errors, but to errors in target choice. The results support the idea that the memory errors seen in schizophrenia patients may be due to saturating the working memory network at relatively low levels of memory load.

  15. A Snapshot of Serial Rape: An Investigation of Criminal Sophistication and Use of Force on Victim Injury and Severity of the Assault.

    Science.gov (United States)

    de Heer, Brooke

    2016-02-01

    Prior research on rapes reported to law enforcement has identified criminal sophistication and the use of force against the victim as possible unique identifiers to serial rape versus one-time rape. This study sought to contribute to the current literature on reported serial rape by investigating how the level of criminal sophistication of the rapist and use of force used were associated with two important outcomes of rape: victim injury and overall severity of the assault. In addition, it was evaluated whether rapist and victim ethnicity affected these relationships. A nation-wide sample of serial rape cases reported to law enforcement collected by the Federal Bureau of Investigation (FBI) was analyzed (108 rapists, 543 victims). Results indicated that serial rapists typically used a limited amount of force against the victim and displayed a high degree of criminal sophistication. In addition, the more criminally sophisticated the perpetrator was, the more sexual acts he performed on his victim. Finally, rapes between a White rapist and White victim were found to exhibit higher levels of criminal sophistication and were more severe in terms of number and types of sexual acts committed. These findings provide a more in-depth understanding of serial rape that can inform both academics and practitioners in the field about contributors to victim injury and severity of the assault. © The Author(s) 2014.

  16. Quantitative proteomic analysis for high-throughput screening of differential glycoproteins in hepatocellular carcinoma serum

    International Nuclear Information System (INIS)

    Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing

    2015-01-01

    Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC

  17. Quick, sensitive serial NMR experiments with Radon transform.

    Science.gov (United States)

    Dass, Rupashree; Kasprzak, Paweł; Kazimierczuk, Krzysztof

    2017-09-01

    The Radon transform is a potentially powerful tool for processing the data from serial spectroscopic experiments. It makes it possible to decode the rate at which frequencies of spectral peaks shift under the effect of changing conditions, such as temperature, pH, or solvent. In this paper we show how it also improves speed and sensitivity, especially in multidimensional experiments. This is particularly important in the case of low-sensitivity techniques, such as NMR spectroscopy. As an example, we demonstrate how Radon transform processing allows serial measurements of 15 N-HSQC spectra of unlabelled peptides that would otherwise be infeasible. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    Science.gov (United States)

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  20. Measuring propagation delay over a coded serial communication channel using FPGAs

    International Nuclear Information System (INIS)

    Jansweijer, P.P.M.; Peek, H.Z.

    2011-01-01

    Measurement and control applications are increasingly using distributed system technologies. In such applications, which may be spread over large distances, it is often necessary to synchronize system timing and know with great precision the time offsets between parts of the system. Measuring the propagation delay over a coded serial communication channel using serializer/deserializer (SerDes) functionality in FPGAs is described. The propagation delay between transmitter and receiver is measured with a resolution of a single unit interval (i.e. a serial link running at 3.125 Gbps provides a 320 ps resolution). The technique has been demonstrated to work over 100 km fibre to verify the feasibility for application in the future KM3NeT telescope.

  1. Serial analysis of gene expression (SAGE)

    NARCIS (Netherlands)

    van Ruissen, Fred; Baas, Frank

    2007-01-01

    In 1995, serial analysis of gene expression (SAGE) was developed as a versatile tool for gene expression studies. SAGE technology does not require pre-existing knowledge of the genome that is being examined and therefore SAGE can be applied to many different model systems. In this chapter, the SAGE

  2. Auditory distraction and serial memory: The avoidable and the ineluctable

    Directory of Open Access Journals (Sweden)

    Dylan M Jones

    2010-01-01

    Full Text Available One mental activity that is very vulnerable to auditory distraction is serial recall. This review of the contemporary findings relating to serial recall charts the key determinants of distraction. It is evident that there is one form of distraction that is a joint product of the cognitive characteristics of the task and of the obligatory cognitive processing of the sound. For sequences of sound, distraction appears to be an ineluctable product of similarity-of-process, specifically, the serial order processing of the visually presented items and the serial order coding that is the by-product of the streaming of the sound. However, recently emerging work shows that the distraction from a single sound (one deviating from a prevailing sequence results in attentional capture and is qualitatively distinct from that of a sequence in being restricted in its action to encoding, not to rehearsal of list members. Capture is also sensitive to the sensory task load, suggesting that it is subject to top-down control and therefore avoidable. These two forms of distraction-conflict of process and attentional capture-may be two consequences of auditory perceptual organization processes that serve to strike the optimal balance between attentional selectivity and distractability.

  3. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng [Yanshan University, Hebei (China)

    2015-10-15

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  4. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    International Nuclear Information System (INIS)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng

    2015-01-01

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  5. Piezoelectric micromotor based on the structure of serial bending arms.

    Science.gov (United States)

    Tong, Jianhua; Cui, Tianhong; Shao, Peige; Wang, Liding

    2003-09-01

    This paper presents a new piezoelectric micromotor based on the structure of serial bending arms. Serial bending arms are composed of two piezoelectric bimorphs with one end fixed and the other end free, driven by two signals of a biased square wave with a phase difference of pi/2. The free end of a cantilever arm will move along an elliptic orbit so that the cantilever is used to drive a cylinder rotor. The rotor's end surface contacts the free end of the cantilever, resulting in the rotor's rotation. There are six serial bending arms anchored on the base. The driving mechanism of the micromotor is proposed and analyzed. A new micromotor prototype, 5 mm in diameter, has been fabricated and characterized. The maximum rotational speed reaches 325 rpm, and the output torque is about 36.5 microNm.

  6. Serum neurofilament light in familial Alzheimer disease: A marker of early neurodegeneration.

    Science.gov (United States)

    Weston, Philip S J; Poole, Teresa; Ryan, Natalie S; Nair, Akshay; Liang, Yuying; Macpherson, Kirsty; Druyeh, Ronald; Malone, Ian B; Ahsan, R Laila; Pemberton, Hugh; Klimova, Jana; Mead, Simon; Blennow, Kaj; Rossor, Martin N; Schott, Jonathan M; Zetterberg, Henrik; Fox, Nick C

    2017-11-21

    To investigate whether serum neurofilament light (NfL) concentration is increased in familial Alzheimer disease (FAD), both pre and post symptom onset, and whether it is associated with markers of disease stage and severity. We recruited 48 individuals from families with PSEN1 or APP mutations to a cross-sectional study: 18 had symptomatic Alzheimer disease (AD) and 30 were asymptomatic but at 50% risk of carrying a mutation. Serum NfL was measured using an ultrasensitive immunoassay on the single molecule array (Simoa) platform. Cognitive testing and MRI were performed; 33 participants had serial MRI, allowing calculation of atrophy rates. Genetic testing established mutation status. A generalized least squares regression model was used to compare serum NfL among symptomatic mutation carriers, presymptomatic carriers, and noncarriers, adjusting for age and sex. Spearman coefficients assessed associations between serum NfL and (1) estimated years to/from symptom onset (EYO), (2) cognitive measures, and (3) MRI measures of atrophy. Nineteen of the asymptomatic participants were mutation carriers (mean EYO -9.6); 11 were noncarriers. Compared with noncarriers, serum NfL concentration was higher in both symptomatic ( p < 0.0001) and presymptomatic mutation carriers ( p = 0.007). Across all mutation carriers, serum NfL correlated with EYO (ρ = 0.81, p < 0.0001) and multiple cognitive and imaging measures, including Mini-Mental State Examination (ρ = -0.62, p = 0.0001), Clinical Dementia Rating Scale sum of boxes (ρ = 0.79, p < 0.0001), baseline brain volume (ρ = -0.62, p = 0.0002), and whole-brain atrophy rate (ρ = 0.53, p = 0.01). Serum NfL concentration is increased in FAD prior to symptom onset and correlates with measures of disease stage and severity. Serum NfL may thus be a feasible biomarker of early AD-related neurodegeneration. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  7. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  8. Serial position learning in honeybees.

    Directory of Open Access Journals (Sweden)

    Randolf Menzel

    Full Text Available Learning of stimulus sequences is considered as a characteristic feature of episodic memory since it contains not only a particular item but also the experience of preceding and following events. In sensorimotor tasks resembling navigational performance, the serial order of objects is intimately connected with spatial order. Mammals and birds develop episodic(-like memory in serial spatio-temporal tasks, and the honeybee learns spatio-temporal order when navigating between the nest and a food source. Here I examine the structure of the bees' memory for a combined spatio-temporal task. I ask whether discrimination and generalization are based solely on simple forms of stimulus-reward learning or whether they require sequential configurations. Animals were trained to fly either left or right in a continuous T-maze. The correct choice was signaled by the sequence of colors (blue, yellow at four positions in the access arm. If only one of the possible 4 signals is shown (either blue or yellow, the rank order of position salience is 1, 2 and 3 (numbered from T-junction. No learning is found if the signal appears at position 4. If two signals are shown, differences at positions 1 and 2 are learned best, those at position 3 at a low level, and those at position 4 not at all. If three or more signals are shown these results are corroborated. This salience rank order again appeared in transfer tests, but additional configural phenomena emerged. Most of the results can be explained with a simple model based on the assumption that the four positions are equipped with different salience scores and that these add up independently. However, deviations from the model are interpreted by assuming stimulus configuration of sequential patterns. It is concluded that, under the conditions chosen, bees rely most strongly on memories developed during simple forms of associative reward learning, but memories of configural serial patterns contribute, too.

  9. Feasibility of Serial Saliva Collection for Surveillance of Swimming-Associated Illness

    Science.gov (United States)

    BACKGROUND. The symptoms of many swimming-associated illnesses overlap, and clinical diagnoses often require serum or stool samples. Therefore, it has been difficult to determine the contributions of different etiologic agents to swimming-associated illness. OBJECTIVES. We collec...

  10. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  11. Ochratoxin A in serum of swine from different Brazilian states.

    Science.gov (United States)

    Krüger, César D; Cavaglieri, Lilia R; Direito, Glória M; Keller, Kelly M; Dalcero, Ana M; da Rocha Rosa, Carlos A

    2010-09-01

    The aims of the current study were to monitor the presence of ochratoxin A (OTA) in the serum of slaughtered swine and to investigate its distribution in 4 major geographical regions of Brazil. A total of 400 samples of serum were collected from 4 major states of Brazil (100 samples each). Ochratoxin A concentrations were determined by high-performance liquid chromatography. In Santa Catarina State, 60% of the samples had OTA concentrations ranging from 4.01 to 75.4 mg/l. In Mato Grosso State, 75% of the samples had OTA concentrations ranging from 0.17 to 46.79 mg/l. Bahia State samples had OTA concentrations ranging from 2.72 to 4.13 mg/l in 36% of the samples, whereas 68% of the samples from Rio de Janeiro State had OTA concentrations ranging from 0.16 to 115 mg/l. Only Santa Catarina State and Rio de Janeiro State had serum samples that exceeded 75 mg/l OTA in 20% and 2% of the samples, respectively. A direct relationship between the higher concentrations of OTA in serum from the States of Santa Catarina and Rio de Janeiro and the highest concentrations of OTA in food intended for animal consumption in the same 2 Brazilian states was found in the present study. Ochratoxin A distribution in foodstuffs is very heterogeneous, and an alternative method by which to monitor the presence of OTA in feed includes analyzing swine serum samples, which reflect the toxin content of the ingested feed. This strategy could prevent the occurrence of ochratoxicosis in animal production, reduce economic losses, and minimize hazards to human health.

  12. Advances in Serials Management. Volume 6.

    Science.gov (United States)

    Hepfer, Cindy, Ed.; Gammon, Julia, Ed.; Malinowski, Teresa, Ed.

    In order to further discussion and support constructive change, this volume presents the following eight papers on various dimensions of serials management: (1) "CD-ROMs, Surveys, and Sales: The OSA [Optical Society of America] Experience" (Frank E. Harris and Alan Tourtlotte); (2) "Management and Integration of Electronic Journals into the…

  13. Impact of Serials Management, Access and Use on Publication Output of Lecturers in Nigerian Universities

    Science.gov (United States)

    Akinbode, Rahmon O. Onaolapo; Nwalo, Kenneth Ivo Ngozi

    2017-01-01

    This study investigates serials management in university libraries, determines the extent to which serials are accessed and used and appraises the influence of availability, accessibility and use of serials on publications output of lecturers in federal universities in Nigeria. Questionnaire administration method was adopted to accumulate data for…

  14. Implications of Market Frictions : Serial Correlations in Indexes on the Emerging Stock Markets in Central and Eastern Europe

    Directory of Open Access Journals (Sweden)

    Joanna Olbrys

    2014-01-01

    Full Text Available Implications of market frictions in the context of serial correlations in indexes on the Central and Eastern European (CEE stock markets have been analysed. Market frictions, such as non-trading effects, bid/ask spreads, other transaction costs, etc., may be detected by direct measurement, or by indirect identification. Direct measurement of frictions is difficult as intraday trading data are unavailable in the case of most of the emerging CEE stock markets. Indirect identification may be conducted by detecting some empirical phenomena. One of them is evidence of serial correlations in indexes, the so-called the Fisher effect. We explore the problem of serial correlations in indexes on the eight CEE stock markets using data samples from each CEE market separately, as well as a "common trading window" approach, which is widely applied in the case of databases with multivariate time series. The evidence is that nonsynchronous trading effect II between markets may substantially disrupt the analysis of index returns on a domestic market. Using a synchronized database, one may erroneously conclude that the Fisher effect does not exist, although it is present. (original abstract

  15. Influence of feeding on serum canine pancreatic lipase immunoreactivity concentrations

    Directory of Open Access Journals (Sweden)

    Steiner JM

    2014-10-01

    Full Text Available Jörg M Steiner, Craig G Ruaux, David A Williams Gastrointestinal Laboratory, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA Abstract: Measurement of serum concentration of pancreatic lipase immunoreactivity (PLI has been shown to be highly specific for exocrine pancreatic function and sensitive for the diagnosis of canine pancreatitis. Currently, it is recommended that food be withheld for at least 12 hours before collecting a blood sample for analysis from dogs. However, it is unknown whether feeding has any influence on serum canine PLI concentration. Thus, the goal of this study was to evaluate the influence of feeding on serum canine PLI concentrations in healthy dogs. Food was withheld from eight healthy adult Beagle dogs for at least 17 hours and a baseline serum sample (0 minutes was collected. Dogs were fed and serum samples were collected at 15, 30, 45, 60, 75, 90, 105, 150, 180, 210, 240, 300, 360, 420, and 480 minutes. There was no significant difference in serum canine PLI concentrations at any time after feeding (P=0.131. We conclude that feeding has no significant influence on serum canine PLI concentrations. Keywords: dog, pancreatic function, pancreatitis, biomarker, diagnostic test

  16. Fungal myositis in children: serial ultrasonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jung Hwa; Lee, Hee Jung; Choi, Jin Soo [Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2003-08-01

    To evaluate serial ultrasonographic findings of fungal myositis in children. Eleven lesions caused by fungal myositis and occurring in six children were included in this study. Eight lesions in five children were histopathologically proven and the other three were clinically diagnosed. Serial ultrasonographic findings were retrospectively evaluated in terms of size, location, margin, internal echotexture and adjacent cortical change occurring during the follow-up period ranging from five days to two months. Three patients (50%) had multiple lesions. The sites of involvment were the thigh (n=4), calf (n=3), chest wall (n=2), abdominal wall (n=1) and forearm (n=1). Initially, diffuse muscular swelling was revealed, with ill-defined hypoechoic lesions confined to the muscle layer (n=8). Follow-up examination of eight lesions over a period of 5-10 days showed that round central echogenic lesions were surrounded by previous slightly echogenic lesions (n=6, 75%). Long-term follow-up of five lesions over a two-month period revealed periosteal thickening in one case (20%), and the peristence of echogenic solid nodules in four (80%). Pathologic examination showed that the central lesions correlated with a fungus ball and the peripheral slightly echogenic lesions corresponded to hematoma and necrosis. Serial ultrasonographic findings of fungal myositis in children revealed relatively constant features in each case. In particular, the findings of muscular necrosis and a fungus ball over a period of 5-14 days were thought to be characteristic.

  17. Fungal myositis in children: serial ultrasonographic findings

    International Nuclear Information System (INIS)

    Kwon, Jung Hwa; Lee, Hee Jung; Choi, Jin Soo

    2003-01-01

    To evaluate serial ultrasonographic findings of fungal myositis in children. Eleven lesions caused by fungal myositis and occurring in six children were included in this study. Eight lesions in five children were histopathologically proven and the other three were clinically diagnosed. Serial ultrasonographic findings were retrospectively evaluated in terms of size, location, margin, internal echotexture and adjacent cortical change occurring during the follow-up period ranging from five days to two months. Three patients (50%) had multiple lesions. The sites of involvment were the thigh (n=4), calf (n=3), chest wall (n=2), abdominal wall (n=1) and forearm (n=1). Initially, diffuse muscular swelling was revealed, with ill-defined hypoechoic lesions confined to the muscle layer (n=8). Follow-up examination of eight lesions over a period of 5-10 days showed that round central echogenic lesions were surrounded by previous slightly echogenic lesions (n=6, 75%). Long-term follow-up of five lesions over a two-month period revealed periosteal thickening in one case (20%), and the peristence of echogenic solid nodules in four (80%). Pathologic examination showed that the central lesions correlated with a fungus ball and the peripheral slightly echogenic lesions corresponded to hematoma and necrosis. Serial ultrasonographic findings of fungal myositis in children revealed relatively constant features in each case. In particular, the findings of muscular necrosis and a fungus ball over a period of 5-14 days were thought to be characteristic

  18. Race as Seriality: A Response to David Benatar and Zimitri Erasmus

    Science.gov (United States)

    Gouws, A.

    2010-01-01

    In this article I draw on the Sarte's notion of "seriality" as theorized in his book "Dialectic of Reason" and as interpreted by Iris Marion Young. I argue that seriality can be used to escape the false essentialism and identity politics of race as a category for admissions to universities. A series is a social collective whose members are unified…

  19. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  20. A high speed serializer ASIC for ATLAS Liquid Argon calorimeter upgrade

    CERN Document Server

    Liu, T; The ATLAS collaboration

    2014-01-01

    We have been developing a serializer application-specific integrated circuit (ASIC) based on a commercial 0.25-μm silicon-on-sapphire (SOS) CMOS technology for the ATLAS liquid argon calorimeter front-end electronics upgrade. The first prototype, a 5 Gbps 16:1 serializer has been designed, fabricated, and tested in lab environment and in 200 MeV proton beam. The test results indicate that the first prototype meets the design goals. The second prototype, a double-lane, 8 Gbps per lane serializer is under development. The post layout simulation indicates that 8 Gbps is achievable. In this paper we present the design and the test results of the first prototype and the design and status of the second prototype.

  1. Facial rejuvenation: Serial fat graft transfer

    African Journals Online (AJOL)

    Saad Mohamed Saad Ibrahiem

    2016-02-01

    Feb 1, 2016 ... This a clinical study carried out to test the aesthetic outcome of serial injection of the cryo-preserved fat cells for both aesthetic and reconstructive purposes. Methods: Clinical ..... ucts, devices, or drugs mentioned in this manuscript that might create a ... Adipose stem cells and regenerative medicine. 7th ed.

  2. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  3. Smart grid serialization comparison: Comparision of serialization for distributed control in the context of the Internet of Things

    DEFF Research Database (Denmark)

    Petersen, Bo Søborg; Bindner, Henrik W.; You, Shi

    2017-01-01

    within a given timeframe, especially in the context of the Internet of Things, using low-bandwidth data connections and constrained devices. The paper shows that there are better alternatives than XML & JAXB and gives guidance in choosing the most appropriate serialization format and library depending...

  4. Analysis of aging in lager brewing yeast during serial repitching.

    Science.gov (United States)

    Bühligen, Franziska; Lindner, Patrick; Fetzer, Ingo; Stahl, Frank; Scheper, Thomas; Harms, Hauke; Müller, Susann

    2014-10-10

    Serial repitching of brewing yeast inoculates is an important economic factor in the brewing industry, as their propagation is time and resource intensive. Here, we investigated whether replicative aging and/or the population distribution status changed during serial repitching in three different breweries with the same brewing yeast strain but different abiotic backgrounds and repitching regimes with varying numbers of reuses. Next to bud scar numbers the DNA content of the Saccharomyces pastorianus HEBRU cells was analyzed. Gene expression patterns were investigated using low-density microarrays with genes for aging, stress, storage compound metabolism and cell cycle. Two breweries showed a stable rejuvenation rate during serial repitching. In a third brewery the fraction of virgin cells varied, which could be explained with differing wort aeration rates. Furthermore, the number of bud scars per cell and cell size correlated in all 3 breweries throughout all runs. Transcriptome analyses revealed that from the 6th run on, mainly for the cells positive gene expression could be seen, for example up-regulation of trehalose and glycogen metabolism genes. Additionally, the cells' settling in the cone was dependent on cell size, with the lowest and the uppermost cone layers showing the highest amount of dead cells. In general, cells do not progressively age during extended serial repitching. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Native sulfur/chlorine SAD phasing for serial femtosecond crystallography

    International Nuclear Information System (INIS)

    Nakane, Takanori; Song, Changyong; Suzuki, Mamoru; Nango, Eriko; Kobayashi, Jun; Masuda, Tetsuya; Inoue, Shigeyuki; Mizohata, Eiichi; Nakatsu, Toru; Tanaka, Tomoyuki; Tanaka, Rie; Shimamura, Tatsuro; Tono, Kensuke; Joti, Yasumasa; Kameshima, Takashi; Hatsui, Takaki; Yabashi, Makina; Nureki, Osamu; Iwata, So; Sugahara, Michihiro

    2015-01-01

    Sulfur SAD phasing facilitates the structure determination of diverse native proteins using femtosecond X-rays from free-electron lasers via serial femtosecond crystallography. Serial femtosecond crystallography (SFX) allows structures to be determined with minimal radiation damage. However, phasing native crystals in SFX is not very common. Here, the structure determination of native lysozyme from single-wavelength anomalous diffraction (SAD) by utilizing the anomalous signal of sulfur and chlorine at a wavelength of 1.77 Å is successfully demonstrated. This sulfur SAD method can be applied to a wide range of proteins, which will improve the determination of native crystal structures

  6. Serum Lipid Profile: Fasting or Non-fasting?

    OpenAIRE

    Nigam, P. K.

    2010-01-01

    Serum lipid profile has now become almost a routine test. It is usually done in fasting state due to certain limitations in non-fasting serum sample. In the recent past efforts have been made to simplify blood sampling by replacing fasting lipid profile with non-fasting lipid profile. However, fasting specimen is preferred if cardiovascular risk assessment is based on total cholesterol, LDL cholesterol or non-HDL cholesterol. A lot has yet to be done in this area. Till then we have to believe...

  7. Evaluation of a type 1 diabetes serum cohort by SELDI-TOF MS protein profiling

    DEFF Research Database (Denmark)

    Albrethsen, J.; Kaas, A.; Schonle, E.

    2009-01-01

    Proteomics analysis of serum from patients with type 1 diabetes (T1D) may lead to novel biomarkers for prediction of disease and for patient monitoring. However, the serum proteome is highly sensitive to sample processing and before proteomics biomarker research serum cohorts should preferably...... be examined for potential bias between sample groups. S ELDI-TOF MS protein profiling was used for preliminary evaluation of a biological-bank with 766 serum samples from 270 patients with T1D, collected at 18 different paediatric centers representing 15 countries in Europe and Japan over 2 years (2000......-2002). Samples collected 1 (n = 270), 6 (n = 248), and 12 (n = 248) months after T1D diagnosis were grouped across centers and compared. The serum protein profiles varied with collection site and day of analysis; however, markers of sample processing were not systematically different between samples collected...

  8. The death of recency: Relationship between end-state comfort and serial position effects in serial recall: Logan and Fischman (2011) revisited.

    Science.gov (United States)

    Logan, Samuel W; Fischman, Mark G

    2015-12-01

    Two experiments examined the dynamic interaction between cognitive resources in short-term memory and bimanual object manipulation by extending recent research by Logan and Fischman (2011). In Experiment 1, 16 participants completed a bimanual end-state comfort task and a memory task requiring serial recall of 12 words or pictures. The end-state comfort task involved moving two glasses between two shelves. Participants viewed the items, performed the end-state comfort task, and then serially recalled the items. Recall was evaluated by the presence or absence of primacy and recency effects. The end-state comfort effect (ESCE) was assessed by the percentage of initial hand positions that allowed the hands to end comfortably. The main findings indicated that the ESCE was disrupted; the primacy effect remained intact; and the recency effect disappeared regardless of the type of memory item recalled. In Experiment 2, 16 participants viewed six items, performed an end-state comfort task, viewed another six items, and then serially recalled all 12 items. Results were essentially the same as in Experiment 1. Findings suggest that executing a bimanual end-state comfort task, regardless of when it is completed during a memory task, diminishes the recency effect irrespective of the type of memory item. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  10. On the Performance of the Python Programming Language for Serial and Parallel Scientific Computations

    Directory of Open Access Journals (Sweden)

    Xing Cai

    2005-01-01

    Full Text Available This article addresses the performance of scientific applications that use the Python programming language. First, we investigate several techniques for improving the computational efficiency of serial Python codes. Then, we discuss the basic programming techniques in Python for parallelizing serial scientific applications. It is shown that an efficient implementation of the array-related operations is essential for achieving good parallel performance, as for the serial case. Once the array-related operations are efficiently implemented, probably using a mixed-language implementation, good serial and parallel performance become achievable. This is confirmed by a set of numerical experiments. Python is also shown to be well suited for writing high-level parallel programs.

  11. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  12. Levels of some trace elements in serum of esophageal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, D M. A. [Sudan Academy of Sciences, Atomic Energy Council, Khartoum (Sudan)

    2011-01-15

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  13. Levels of some trace elements in serum of esophageal cancer patients

    International Nuclear Information System (INIS)

    Saeed, D. M. A.

    2011-01-01

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  14. Virulence-associated genome mutations of murine rotavirus identified by alternating serial passages in mice and cell cultures.

    Science.gov (United States)

    Tsugawa, Takeshi; Tatsumi, Masatoshi; Tsutsumi, Hiroyuki

    2014-05-01

    Although significant clinical efficacy and safety of rotavirus vaccines were recently revealed in many countries, the mechanism of their attenuation is not well understood. We passaged serially a cell culture-adapted murine rotavirus EB strain in mouse pups or in cell cultures alternately and repeatedly and fully sequenced all 11 genes of 21 virus samples passaged in mice or in cell cultures. Sequence analysis revealed that mouse-passaged viruses that regained virulence almost consistently acquired four kinds of amino acid (aa) substitutions in VP4 and substitution in aa 37 (Val to Ala) in NSP4. In addition, they gained and invariably conserved the 3' consensus sequence in NSP1. The molecular changes occurred along with the acquisition of virulence during passages in mice and then disappeared following passages in cell cultures. Intraperitoneal injection of recombinant NSP4 proteins confirmed the aa 37 site as important for its diarrheagenic activity in mice. These genome changes are likely to be correlated with rotavirus virulence. Serial passage of a virulent wild-type virus in vitro often results in loss of virulence of the virus in an original animal host, while serial passage of a cell culture-adapted avirulent virus in vivo often gains virulence in an animal host. Actually, live attenuated virus vaccines were originally produced by serial passage in cell cultures. Although clinical efficacy and safety of rotavirus vaccines were recently revealed, the mechanism of their attenuation is not well understood. We passaged serially a murine rotavirus by alternating switch of host (mice or cell cultures) repeatedly and sequenced the eleven genes of the passaged viruses to identify mutations associated with the emergence or disappearance of virulence. Sequence analysis revealed that changes in three genes (VP4, NSP1, and NSP4) were associated with virulence in mice. Intraperitoneal injection of recombinant NSP4 proteins confirmed its diarrheagenic activity in mice

  15. Virulence-Associated Genome Mutations of Murine Rotavirus Identified by Alternating Serial Passages in Mice and Cell Cultures

    Science.gov (United States)

    Tatsumi, Masatoshi; Tsutsumi, Hiroyuki

    2014-01-01

    ABSTRACT Although significant clinical efficacy and safety of rotavirus vaccines were recently revealed in many countries, the mechanism of their attenuation is not well understood. We passaged serially a cell culture-adapted murine rotavirus EB strain in mouse pups or in cell cultures alternately and repeatedly and fully sequenced all 11 genes of 21 virus samples passaged in mice or in cell cultures. Sequence analysis revealed that mouse-passaged viruses that regained virulence almost consistently acquired four kinds of amino acid (aa) substitutions in VP4 and substitution in aa 37 (Val to Ala) in NSP4. In addition, they gained and invariably conserved the 3′ consensus sequence in NSP1. The molecular changes occurred along with the acquisition of virulence during passages in mice and then disappeared following passages in cell cultures. Intraperitoneal injection of recombinant NSP4 proteins confirmed the aa 37 site as important for its diarrheagenic activity in mice. These genome changes are likely to be correlated with rotavirus virulence. IMPORTANCE Serial passage of a virulent wild-type virus in vitro often results in loss of virulence of the virus in an original animal host, while serial passage of a cell culture-adapted avirulent virus in vivo often gains virulence in an animal host. Actually, live attenuated virus vaccines were originally produced by serial passage in cell cultures. Although clinical efficacy and safety of rotavirus vaccines were recently revealed, the mechanism of their attenuation is not well understood. We passaged serially a murine rotavirus by alternating switch of host (mice or cell cultures) repeatedly and sequenced the eleven genes of the passaged viruses to identify mutations associated with the emergence or disappearance of virulence. Sequence analysis revealed that changes in three genes (VP4, NSP1, and NSP4) were associated with virulence in mice. Intraperitoneal injection of recombinant NSP4 proteins confirmed its

  16. Impaired Processing of Serial Order Determines Working Memory Impairments in Alzheimer's Disease.

    Science.gov (United States)

    De Belder, Maya; Santens, Patrick; Sieben, Anne; Fias, Wim

    2017-01-01

    Working memory (WM) problems are commonly observed in Alzheimer's disease (AD), but the affected mechanisms leading to impaired WM are still insufficiently understood. The ability to efficiently process serial order in WM has been demonstrated to be fundamental to fluent daily life functioning. The decreased capability to mentally process serial position in WM has been put forward as the underlying explanation for generally compromised WM performance. Determine which mechanisms, such as order processing, are responsible for deficient WM functioning in AD. A group of AD patients (n = 32) and their partners (n = 25), assigned to the control group, were submitted to an extensive battery of neuropsychological and experimental tasks, assessing general cognitive state and functioning of several aspects related to serial order WM. The results revealed an impaired ability to bind item information to serial position within WM in AD patients compared to controls. It was additionally observed that AD patients experienced specific difficulties with directing spatial attention when searching for item information stored in WM. The processing of serial order and the allocation of attentional resources are both disrupted, explaining the generally reduced WM functioning in AD patients. Further studies should now clarify whether this observation could explain disease-related problems for other cognitive functions such as verbal expression, auditory comprehension, or planning.

  17. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  18. Use of serum and blood samples on filter paper to improve the surveillance of Dengue in Pacific Island Countries.

    Science.gov (United States)

    Aubry, Maite; Roche, Claudine; Dupont-Rouzeyrol, Myrielle; Aaskov, John; Viallon, Jérôme; Marfel, Maria; Lalita, Paul; Elbourne-Duituturaga, Salanieta; Chanteau, Suzanne; Musso, Didier; Pavlin, Boris I; Harrison, Dustin; Kool, Jacob L; Cao-Lormeau, Van-Mai

    2012-09-01

    In Pacific Island Countries (PICs) the epidemiology of dengue is characterized by long-term transmission of a single dengue virus (DENV) serotype. The emergence of a new serotype in one island country often indicates major outbreaks with this serotype will follow in other PICs. Filter paper (FP) cards on which whole blood or serum from dengue suspected patients had been dried was evaluated as a method for transportation of this material by standard mail delivery throughout the Pacific. Twenty-two FP-dried whole blood samples collected from patients in New Caledonia and Wallis & Futuna Islands, during DENV-1 and DENV-4 transmission, and 76 FP-dried sera collected from patients in Yap State, Majuro (Republic of Marshall Islands), Tonga and Fiji, before and during outbreaks of DENV-2 in Yap State and DENV-4 in Majuro, were tested for the presence of DENV RNA, by serotype specific RT-PCR, at the Institut Louis Malardé in French Polynesia. The serotype of DENV could be determined, by a variety of RT-PCR procedures, in the FP-dried samples after more than three weeks of transport at ambient temperatures. In most cases, the sequencing of the envelope gene to genotype the viruses also was possible. The serotype and genotype of DENV can be determined from FP-dried serum or whole blood samples transported over thousands of kilometers at ambient, tropical, temperatures. This simple and low-cost approach to virus identification should be evaluated in isolated and resource poor settings for surveillance for a range of significant viral diseases. Copyright © 2012. Published by Elsevier B.V.

  19. Serializing off-the-shelf MOSFETs by Magnetically Coupling Their Gate Electrodes

    DEFF Research Database (Denmark)

    Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2013-01-01

    While the semiconductor industry struggles with the inherent trade-offs of solid-state devices, serialization of power switches, like the Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) or the Insulated Gate Bipolar Transistor (IGBT), has been proven to be an advantageous alternative...... to acquire a high-efficient, high-voltage, fast-switching device. More than twenty years of research, on the serialization of solid-state devices, have resulted into several different stacking concepts. Among the prevailing ones, the gate balancing core technique, which has demonstrated very good performance...... in strings of high-power IGBT modules. In this paper, the limitations of the gate balancing core technique, when employed to serialize low or medium power off-the-shelf switches, are identified via experimental results. A new design specification for the interwinding capacitance of the employed transformer...

  20. Recalling visual serial order for verbal sequences

    NARCIS (Netherlands)

    Logie, R.H.; Saito, S.; Morita, A.; Varma, S.; Norris, D.

    2016-01-01

    We report three experiments in which participants performed written serial recall of visually presented verbal sequences with items varying in visual similarity. In Experiments 1 and 2 native speakers of Japanese recalled visually presented Japanese Kanji characters. In Experiment 3, native speakers

  1. A matter of emphasis: Linguistic stress habits modulate serial recall.

    Science.gov (United States)

    Taylor, John C; Macken, Bill; Jones, Dylan M

    2015-04-01

    Models of short-term memory for sequential information rely on item-level, feature-based descriptions to account for errors in serial recall. Transposition errors within alternating similar/dissimilar letter sequences derive from interactions between overlapping features. However, in two experiments, we demonstrated that the characteristics of the sequence are what determine the fates of items, rather than the properties ascribed to the items themselves. Performance in alternating sequences is determined by the way that the sequences themselves induce particular prosodic rehearsal patterns, and not by the nature of the items per se. In a serial recall task, the shapes of the canonical "saw-tooth" serial position curves and transposition error probabilities at successive input-output distances were modulated by subvocal rehearsal strategies, despite all item-based parameters being held constant. We replicated this finding using nonalternating lists, thus demonstrating that transpositions are substantially influenced by prosodic features-such as stress-that emerge during subvocal rehearsal.

  2. Serial consolidation of orientation information into visual short-term memory.

    Science.gov (United States)

    Liu, Taosheng; Becker, Mark W

    2013-06-01

    Previous research suggests that there is a limit to the rate at which items can be consolidated in visual short-term memory (VSTM). This limit could be due to either a serial or a limited-capacity parallel process. Historically, it has proven difficult to distinguish between these two types of processes. In the present experiment, we took a novel approach that allowed us to do so. Participants viewed two oriented gratings either sequentially or simultaneously and reported one of the gratings' orientation via method of adjustment. Performance was worse for the simultaneous than for the sequential condition. We fit the data with a mixture model that assumes performance is limited by a noisy memory representation plus random guessing. Critically, the serial and limited-capacity parallel processes made distinct predictions regarding the model's guessing and memory-precision parameters. We found strong support for a serial process, which implies that one can consolidate only a single orientation into VSTM at a time.

  3. Serial analysis of resected prostate cancer suggests up-regulation of type 1 IGF receptor with disease progression.

    Science.gov (United States)

    Turney, Benjamin W; Turner, Gareth D H; Brewster, Simon F; Macaulay, Valentine M

    2011-05-01

    • To compare immunostaining protocols using different antibodies for the type 1 insulin-like growth factor receptor (IGF-1R) in channel transurethal resection of the prostate (chTURP) chips, and to investigate how IGF-1R expression varies with time in serial prostate cancer specimens from individual patients. • We studied IGF-1R expression in 44 prostate cancer specimens from 18 patients who had undergone serial chTURP at least 3 months apart. • Retrospective analysis of the hospital notes was undertaken to obtain clinical information, including age, Gleason score, prostate-specific antigen (PSA) level, hormone treatment and metastatic disease status at the time of each operation. • After an optimization process using three commercially-available IGF-1R antibodies, we used two antibodies for semiquantititve immunostaining of serial chTURP chips. • Santa Cruz antibody sc713 gave positive staining in IGF-1R null R- cells, and was not used further. Antibodies from Cell Signaling Technology (Beverly, MA, USA) (CS) and NeoMarkers Inc. (Fremont, CA, USA) (NM) did not stain R- cells and, in prostate tissue, showed staining of the glandular epithelium, with negligible stromal staining. All 44 chTURP samples contained identifiable malignant tissue and, of these, 73% and 64% scored moderately or strongly (score 3 or 4) with the CS and NM antibodies respectively. • There was significant correlation of IGF-1R scores of malignant tissue between the two antibodies (P < 0.001). By contrast, staining of benign glands showed poor correlation between antibodies: CS gave significantly weaker staining than malignant epithelium in the same sections (P < 0.001), whereas NM showed poor discrimination between malignant and benign glands. IGF-1R staining scores generated by the CS antibody were used to analyze the clinical data. • Most patients (six of seven) with falling IGF-1R staining scores were responding to androgen deprivation therapy (confirmed by PSA response

  4. [Some criminological and psychopathologic reflexions about serial crimes].

    Science.gov (United States)

    Romi, Juan Carlos

    2011-01-01

    This article reviews the concept of serial crime, including murder as well as any action for the purpose of inflicting bodily harm upon any person. It characterizes three types of multi-murderers: serial killers, mass murderers, and spree killers. These offenders often have a specific (ritual) behavior that is idiosyncratic and repeated on each crime, which allows the psychological profiling of the murderer. Examples, a psychopathological background, and a description of both their criminal behavior and dynamics are provided for each of these criminals. They are further classified according to their different motivations: psychotic, prophetic or enlightened, pleasure, secondary or pecuniary profits, power or control. Finally, the author shares his personal experience over 20 years in the assessment of sexual offenders.

  5. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  6. Evaluation of HER2/neu oncoprotein in serum & tissue samples of women with breast cancer

    Directory of Open Access Journals (Sweden)

    Shailaja Shukla

    2016-01-01

    Interpretation & conclusions: The results suggest that elevated serum HER2 level was associated with a clinicopathological aggressive phenotype of breast carcinoma and was related to tissue HER2 overexpression. Therefore, serum HER2 may be useful for monitoring the course of the disease and response to treatment.

  7. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  8. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  9. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  10. Woody Allen, serial schlemiel ?

    Directory of Open Access Journals (Sweden)

    Frédérique Brisset

    2011-04-01

    Full Text Available Woody Allen a développé au fil des années une persona cinématographique de schlemiel new-yorkais aisément reconnaissable par le spectateur. Elle marque nombre de ses films, qu’il y apparaisse en tant qu’acteur ou y dirige des substituts comédiens comme déclinaisons de lui-même. Si cette figure prototypique est le fondement de la sérialité dans sa filmographie, il est des traits stylistiques qui en portent trace tout au long de son œuvre : la récurrence annuelle de ses réalisations, la signature formelle symbolisée par ses génériques à la typographie singulière, le rythme de ses dialogues ponctués d’interjections et l’usage de l’autocitation sont autant de procédés qui marquent son cinéma d’un sceau très personnel. Ils fonctionnent comme des clins d’œil au spectateur qui reçoit dès lors LE Woody Allen millésimé comme une invitation à retrouver son microcosme. Ainsi la sérialité se pose comme à la fois initiale et conséquentielle de son système filmique, processus de création unique dans le cinéma américain.Woody Allen has long constructed a cinematographic persona of schlemiel New- Yorker that the audience can easily identify. It impacts most of his films, whether he stars in them or directs “substitute” actors to impersonate his character. If this prototypical figure is the basis of seriality in his cinematography, serial stylistic features can also be found all along his career: the annual recurrence of his productions, the formal signature symbolised by the typography of his singular credit titles, his rhythmical interjection-punctuated dialogues and the use of self-quotation imprint a very personal seal upon his movies. They all work as a recognition signals for the audience who thus receive THE Woody Allen vintage as an invitation to re-enter his microcosm. Seriality is then both initial and consequential to his cinematographic system, a unique creative process in American film history.

  11. Advanced prostatic carcinomas with low serum levels of prostate-specific antigen

    Directory of Open Access Journals (Sweden)

    Cerović Snežana J.

    2002-01-01

    Full Text Available The serum levels of prostate-specific antigen (PSA represent a significant diagnostic and monitoring parameter of prostatic carcinoma (PC. The aim of the study was to establish correlation of serum PSA level in addition to grade, histological type, and clinical stage of PC in patients with normal or intermediary PSA serum level. In 37 untreated PC patients with preoperative serum PSA levels ranging between 0.1 and 9.6 ng/ml, paraffin-embedded tissue and serum samples were immunohistological studied and immunoassay for PSA was done. The most representative was poorly differentiated PC with D stage In serum samples from PC patients 27 (73.7% normal (≤ 4.0 ng/ml, and 10 (27.3% intermediate (4.1-10 ng/ml PSA levels were found Immunohistochemistry, in 36 PC (97.3% had demonstrated the expression of PSA. Our study results had shown low serum PSA levels in some patients with advanced poorly differentiated PC.

  12. Juvenility and serial vegetative propagation of Norway spruce clones (Picea abies Karst.).

    Science.gov (United States)

    J.B. St. Clair; J. Kleinschmit; J. Svolba

    1985-01-01

    Effects associated with progressive maturation of clones are of greatest concern in clonal tree improvement programs. Serial propagation has been in use at the Lower Saxony Forest Research Institute since 1968 to arrest maturation in Norway spruce clones. By 1980 cuttings were established in the nursery that had been serially propagated from one to five cycles. This...

  13. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  14. Total and ionized serum magnesium and calcium levels during magnesium sulfate administration for preterm labor

    Science.gov (United States)

    Kim, Won Hee; An, Yuna; Moon, Jong Ho; Noh, Eun Ji; Kim, Jong Woon

    2018-01-01

    Objective This study aimed to estimate the association between total and ionized magnesium, and the changes in serum magnesium and calcium levels in patients with preterm labor during magnesium sulfate (MgSO4) administration. Methods The study population included 64 women who were candidates for intravenous MgSO4 treatment for preterm labor. Serial blood samples were taken and measured total magnesium (T-Mg), ionized magnesium (I-Mg), total calcium (T-Ca), and ionized calcium (I-Ca) levels every one-week interval (1st, 2nd, 3rd). Results There was no significant difference in T-Mg and I-Mg levels during MgSO4 administration (P>0.05). There was no significant difference in T-Ca and I-Ca levels during MgSO4 administration (P>0.05). Compared before and after administration of MgSO4, T-Mg and I-Mg levels and T-Ca levels were changed allow statistically significant (P0.05). There was significant correlation between levels of I-Mg and T-Mg (I-Mg=0.395×T-Mg+0.144, P<0.01). Conclusion There were no significant differences in serum Mg and Ca levels during MgSO4 administration for preterm labor. Compared to the before and after administration of MgSO4, only I-Ca levels were not substantially changed. There are significant correlations between I-Mg and T-Mg levels during administration of MgSO4 and I-Mg level seemed to have more correlation with adverse effect than T-Mg. PMID:29372150

  15. Serials Management In Polytechnic Libraries in Nigeria: A ...

    African Journals Online (AJOL)

    Serials Management In Polytechnic Libraries in Nigeria: A Comparative Study of Kaduna Polytechnic And Yaba College of Technology Libraries. ... Samaru Journal of Information Studies. Journal Home · ABOUT THIS JOURNAL · Advanced ...

  16. Control of gynaecological radiotherapy by serial tumormarker determinations

    International Nuclear Information System (INIS)

    Wagner, R.K.; Atzinger, A.; Breit, A.

    1990-01-01

    In 149 collum and 45 corpus carcinomas tumormarker concentrations in serum have been measured before, during and sex to eight weeks after termination of radiotherapy. For the collum carcinomas (average of FIGO I to IV) the sensitivity of CEA was found to be 51%, SCC 67%, CEA+SCC 80%. In corpus carcinomas CEA had low sensitivity and could not readily be used for therapy monitoring. However, in a number of cases CA125 was a good substitute. Six to eight weeks after termination of radiotherapy the average tumormarker levels have been declined by comparison with the pretherapeutical values (100%): For the collum carcinoma CEA droped to 39%, SCC to 57%; for the corpus carcinoma CEA to 72%, CA 125 to 81%. The highest diagnostic information was gained by comparison of post-therapeutical tumormarker levels with cut off values optained from healthy women of the same age group. After treatment in 29 of 106 collum carcinomas CEA and or SCC levels did still exceed these cut off values. In eleven cases this marker elevation was due to paraaortic lymphnode metastases, in seven cases a lokal tumor residue was discovered and in six cases general metastases. In corpus carcinomas the main reason for posttherapeutical elevated CA125 values also were paraaortic lymphnode metastases. Thus, the use of serial tumormarker determination for control of gynecological radiotherapy is helpful tool in early detecting local tumorresidues and metastases. The decision making for further radiotherapeutical measures will be much easier, if accompaniing tumormarker determinations have been done during primary radiotherapy. (orig./MG) [de

  17. Maldi-Tof /Tof-MS Reveals Elevated Serum Haptoglobin and Amyloid A in Behcet's Disease

    NARCIS (Netherlands)

    Mao, L.; Dong, H.; Yang, P.; Zhou, H.; Huang, X.; Lin, X.; Kijlstra, A.

    2008-01-01

    Behcet¿s disease (BD) is a multisystemic autoimmune disease with unclear etiology and pathogenesis. To screen aberrant serum proteins in BD, serum samples were obtained from eight male BD patients with active uveitis and eight male healthy volunteers with informed consent. The serum samples from

  18. The Functional Determinants of Short-Term Memory: Evidence from Perceptual-Motor Interference in Verbal Serial Recall

    Science.gov (United States)

    Hughes, Robert W.; Marsh, John E.

    2017-01-01

    A functional, perceptual-motor, account of serial short-term memory (STM) is examined by investigating the way in which an irrelevant spoken sequence interferes with verbal serial recall. Even with visual list-presentation, verbal serial recall is particularly susceptible to disruption by irrelevant spoken stimuli that have the same identity…

  19. Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.

    Science.gov (United States)

    Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto

    2017-04-01

    Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  20. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  1. Effect of parental family history of Alzheimer's disease on serial position profiles.

    Science.gov (United States)

    La Rue, Asenath; Hermann, Bruce; Jones, Jana E; Johnson, Sterling; Asthana, Sanjay; Sager, Mark A

    2008-07-01

    An exaggerated recency effect (ie, disproportionate recall of last-presented items) has been consistently observed in the word list learning of patients with Alzheimer's disease (AD). Our study sought to determine whether there were similar alterations in serial position learning among asymptomatic persons at risk for AD as a result of parental family history. Subjects included 623 asymptomatic middle-aged children of patients with AD (median, 53 years) and 157 control participants whose parents survived to at least age 70 without AD or other memory disorders. All participants were administered the Rey Auditory Verbal Learning Test, which requires learning and recall of 15 unrelated nouns. There was no significant difference in total words recalled between the AD children and control groups. However, compared with controls, AD children exhibited a significantly greater tendency to recall words from the end (recency) versus beginning (primacy) of the list. Serial position effects were unrelated to apolipoprotein allele epsilon 4 or depressive symptoms. Asymptomatic persons at risk for AD by virtue of family history do not show a difference in total words recalled compared with controls, but they exhibit a distinctly different serial position curve, suggesting greater reliance on immediate as opposed to episodic memory. This is the same serial position pattern observed in mild AD, seen here in reduced severity. Longitudinal follow-up is planned to determine whether changes in serial position patterns are a meaningful marker for preclinical detection of AD.

  2. Neurodevelopmental and psychosocial risk factors in serial killers and mass murderers

    OpenAIRE

    Allely, Clare S.; Minnis, Helen; Thompson, Lucy; Wilson, Philip; Gillberg, Christopher

    2014-01-01

    Multiple and serial murders are rare events that have a very profound societal impact. We have conducted a systematic review, following PRISMA guidelines, of both the peer reviewed literature and of journalistic and legal sources regarding mass and serial killings. Our findings tentatively indicate that these extreme forms of violence may be a result of a highly complex interaction of biological, psychological and sociological factors and that, potentially, a significant proportion of mass or...

  3. Malingering, coaching, and the serial position effect.

    Science.gov (United States)

    Suhr, Julie A

    2002-01-01

    The normal pattern of performance on list-learning tasks is to recall more words from the beginning (primacy) and end (recency) of the list. This pattern is also seen in patients with closed head injury, but malingerers tend to recall less words from the beginning of word lists, leading to a suppressed primacy effect. The present study examined this pattern on both learning trials and delayed recall of the Auditory Verbal Learning Test (AVLT) in 34 persons performing with normal effort, 38 naive malingerers, 33 warned malingerers, and 29 head-injured patients. Both malingering groups had lower scores on the primacy portion of the list during learning trials, while normals and head-injured patients had normal serial position curves. During delayed recall, normals and head-injured patients did better than the two malingering groups on middle and recency portions of the list. Findings suggest that the serial position effect during learning trials may be a useful pattern of performance to watch for when suspicious of malingering.

  4. Increased Circulating Level of the Survival Factor GP88 (Progranulin in the Serum of Breast Cancer Patients When Compared to Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Katherine Rak Tkaczuk

    2011-01-01

    Full Text Available Introduction GP88 (PC-Cell Derived Growth Factor, progranulin is a glycoprotein overexpressed in breast tumors and involved in their proliferation and survival. Since GP88 is secreted, an exploratory study was established to compare serum GP88 level between breast cancer patients (BC and healthy volunteers (HV. Methods An IRB approved prospective study enrolled 189 stage 1–4 BC patients and 18 HV. GP88 serum concentration was determined by immunoassay. Results Serum GP88 level was 28.7+ 5.8 ng/ml in HV and increased to 40.7+ 16.0 ng/ml ( P = 0.007 for stage 1-3 and 45.3 +23.3 ng/ml ( P = 0.0007 for stage 4 BC patients. There was no correlation between the GP88 level and BC characteristics such as age, race, tumor grade, ER, PR and HER-2 expression. Conclusion These data suggest that serial testing of serum GP88 levels may have value as a circulating biomarker for detection, monitoring and follow up of BC.

  5. Serum erythropoietin levels by radioimmunoassay in polycythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Birgegaard, G.; Miller, O.; Caro, J.; Erslev, A. (Cardeza Foundation for Hematological Research, Jefferson University, Philadelphia, Pa.)

    1982-01-01

    A radioimmunoassay (RIA) method for erythropoietin (Epo) was developed and validated against the polycythaemic mouse assay. The correlation was good, with a r=0.94. Several other criteria of specificity were also filled by the RIA, which had a lower detection limit of 5 mU/ml. The mean serum-Epo level in 6 patients with secondary polycythaemia, 50.2 +- 26.2 mU/ml, was significantly higher than in a group of 11 normal subjects, 28.7 +- 7.2 mU/ml (P<0.0002). However, the Epo level in 31 polycythaemia vera (PV) patients, M = 21.9 +- 6.6 mU/ml, was not significantly different from normal (P = 0.006). Since previous studies with bioassay of heat-treated and concentrated plasma samples have shown a decreased serum-Epo level in PV, Epo levels were measured before and after heat treatment and concentration of samples from normals and polycythaemics. It was found that the levels of immunoreactive material increased after heat treatment and 40 times concentration in samples from normals and patients with secondary polycythaemias, but decreased in PV. We conclude that the Epo levels in serum in the low range measured by our and previous RIA:s probably are not true Epo levels but are partly due to an unspecific serum effect, that was removed by heat treatment.

  6. BRAIN Journal - Some Considerations on Seriality and Synchronicity

    OpenAIRE

    Elena Nechita

    2017-01-01

    ABSTRACT This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  7. Fault tolerance based on serial communication of FPGA

    International Nuclear Information System (INIS)

    Peng Jing; Fang Zongliang; Xu Quanzhou; Hu Jiewei; Ma Guizhen

    2012-01-01

    There maybe appear mistake in serial communication. This paper was described the intellectual detector of γ dose ratemeter communication with FPGA. The software of FPGA designed the code about fault tolerance, prevented mistake effectively. (authors)

  8. Predictive performance of TPA testing for recurrent disease during follow-up after curative intent surgery for colorectal carcinoma

    NARCIS (Netherlands)

    van der Sluis, Frederik J.; Zhan, Zhuozhao; Verberne, Charlotte J.; Muller Kobold, Anneke C.; Wiggers, Theo; de Bock, Geertruida H.

    Background: The aim of the present study was to investigate the predictive performance of serial tissue polypeptide antigen (TPA) testing after curative intent resection for detection of recurrence of colorectal malignancy. Methods: Serum samples were obtained in 572 patients from three different

  9. Cardiac troponin T and CK-MB mass release after visually successful percutaneous transluminal coronary angioplasty in stable angina pectoris

    DEFF Research Database (Denmark)

    Ravkilde, J; Nissen, H; Mickley, H

    1994-01-01

    The incidence of cardiac troponin T (Tn-T) and creatine kinase (CK) isoenzyme MB mass release was studied in 23 patients with stable angina pectoris undergoing visually successful percutaneous transluminal coronary angioplasty (PTCA). Serial blood samples were drawn for measurement of serum Tn...

  10. [Trend of the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Retrospective analysis of serum samples of the years 2006-2015].

    Science.gov (United States)

    Müller, A; Freude, B

    2016-01-01

    An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45  068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40  949 samples (30  462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply,  150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.

  11. Increase in serum albumin concentration is associated with prediabetes development and progression to overt diabetes independently of metabolic syndrome.

    Science.gov (United States)

    Jun, Ji Eun; Lee, Seung-Eun; Lee, You-Bin; Jee, Jae Hwan; Bae, Ji Cheol; Jin, Sang-Man; Hur, Kyu Yeon; Lee, Moon-Kyu; Kim, Jae Hyeon

    2017-01-01

    Serum albumin concentration is associated with both type 2 diabetes and metabolic syndrome (MetS). We sought to investigate whether baseline serum albumin and change in serum albumin could be independent risk factors for prediabetes in subjects without MetS. We further examined the effect of serum albumin on progression to overt diabetes in subjects who developed prediabetes. Among 10,792 participants without diabetes and MetS who consecutively underwent yearly health check-ups over six years, 9,807 subjects without incident MetS were enrolled in this longitudinal retrospective study. The risk of developing prediabetes (impared fasting glucose or hemoglobin A1c) was analyzed according to baseline and percent change in serum albumin concentration using Cox regression analysis. Serial changes in serum albumin concentration were measured from baseline to one year before prediabetes diagnosis, and then from the time of prediabetes diagnosis to progression to overt diabetes or final follow-up. A total of 4,398 incident cases of prediabetes developed during 35,807 person-years (median 3.8 years). The hazard ratio for incident prediabetes decreased as percent change in serum albumin concentration (quartiles and per 1%) increased in a crude and fully adjusted model. However, baseline serum albumin concentration itself was not associated with prediabetic risk. Serum albumin levels kept increasing until the end of follow-up in prediabetic subjects who returned to normal glycemic status, whereas these measures did not change in prediabetic subjects who developed type 2 diabetes. Serum albumin concentration measured at the end of follow-up was the highest in the regression group, compared to the stationary (p = 0.014) or progression groups (p = 0.009). Increase in serum albumin concentration might protect against early glycemic deterioration and progression to type 2 diabetes even in subjects without MetS.

  12. Ranking serials in oceanography: An analysis based on the Indian contributions and their citations

    Digital Repository Service at National Institute of Oceanography (India)

    Tapaswi, M.P.; Maheswarappa, B.S.

    An analysis of serials preferred and cited in various communications by the Indian oceanographers during 1963 to 1992 is presented. A shift in preference of serials from general sciences to oceanography (interdisciplinary) and to core subject...

  13. Aspects of the Hematology and Serum Biochemistry of Sahel and ...

    African Journals Online (AJOL)

    This study was conducted to investigate effects of year, age, season and breeds on aspects of the hematology and serum biochemical indices of Sahel and Sokoto red bucks in Mubi, Adamawa state, Nigeria. Blood and serum samples were used to determine PCV, Hb, RBC and WBC, and while serum protein (BSP) and ...

  14. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. A serial founder effect model for human settlement out of Africa

    OpenAIRE

    Deshpande, Omkar; Batzoglou, Serafim; Feldman, Marcus W.; Luca Cavalli-Sforza, L.

    2008-01-01

    The increasing abundance of human genetic data has shown that the geographical patterns of worldwide genetic diversity are best explained by human expansion out of Africa. This expansion is modelled well by prolonged migration from a single origin in Africa with multiple subsequent serial founding events. We discuss a new simulation model for the serial founder effect out of Africa and compare it with results from previous studies. Unlike previous models, we distinguish colonization events fr...

  16. Comparing Young and Elderly Serial Reaction Time Task Performance on Repeated and Random Conditions

    Directory of Open Access Journals (Sweden)

    Fatemeh Ehsani

    2012-07-01

    Full Text Available Objectives: Acquisition motor skill training in elderly is at great importance. The main purpose of this study was to compare young and elderly performance in serial reaction time task on different repeated and random conditions. Methods & Materials: A serial reaction time task by using software was applied for studying motor learning in 30 young and 30 elderly. Each group divided randomly implicitly and explicitly into subgroups. A task 4 squares with different colors appeared on the monitor and subjects were asked to press its defined key immediately after observing it. Subjects practiced 8 motor blocks (4 repeated blocks, then 2 random blocks and 2 repeated blocks. Block time that was dependent variable measured and Independent-samples t- test with repeated ANOVA measures were used in this test. Results: young groups performed both repeated and random sequences significantly faster than elderly (P0.05. Explicit older subgroup performed 7,8 blocks slower than 6 block with a significant difference (P<0.05. Conclusion: Young adults discriminate high level performance than elderly in both repeated and random practice. Elderly performed random practice better than repeated practice.

  17. Technical report: serial collections of placentomes during parturition in cattle and subsequent reproductive performance.

    Science.gov (United States)

    McNeel, Anthony K; Ondrak, Jeff D; Cushman, Robert A

    2013-05-01

    Placental separation is a complex physiological event in reproductive physiology and the underlying molecular mechanisms remain unclear. When comparing different experiments the timing of tissue collections is a significant consideration due to the variability in time between fetal expulsion and expulsion of the placenta (30 min to >24 h). This makes comparison of tissues samples across animals difficult and supports the need for serial tissue collections within animal. Additionally, the instrument most commonly used, a modified Richter-Resinsinger effeminator, for placentome collections is difficult to obtain and there are no data in the literature record regarding subsequent reproductive performance of animals subjected placentome collections. To facilitate continued research into the physiology behind placental separation, we designed an instrument from readily available components and performed serial transvaginal placentome collections in cattle. Three placentomes at 2-h intervals were collected after expulsion of the calf in 18 multiparous cows. There was no incidence of mortality and all cows resumed estrous after the procedure. Neither time from placentome collection nor age had a significant effect on pregnancy status at diagnosis (P > 0.05). These results demonstrate the viability of and utility of this device for collecting multiple placentomes in cattle.

  18. Rapid detection of cytomegalovirus in bronchoalveolar lavage fluid and serum samples by polymerase chain reaction: correlation of virus isolation and clinical outcome for patients with human immunodeficiency virus infection

    DEFF Research Database (Denmark)

    Hansen, K K; Vestbo, Jørgen; Benfield, T

    1997-01-01

    Bronchoalveolar lavage (BAL) fluids and serum samples from 153 patients with pulmonary symptoms who were infected with human immunodeficiency virus (HIV) and underwent BAL were examined for the presence of cytomegalovirus (CMV) by conventional culture and by polymerase chain reaction (PCR...... technique than conventional culture. Detection of CMV DNA in BAL fluid or serum predicted subsequent development of extrapulmonary CMV disease but not death for HIV-infected patients with pulmonary symptoms....

  19. Competitive radioimmunoassay of digoxin in serum

    International Nuclear Information System (INIS)

    Oslapas, Raymond; Herrin, T.R.

    1975-01-01

    The process described is for determining the digoxin level of a serum. To do so a mixture is made by adding to the serum sample an antidigoxin antibody and a suitable labelling quantity of O 3 -(hydroxy-4 phenethylcarbamoyl)digoxigenin for radioactive labelling. The mixture is allowed to incubate so that the digoxin of the sample and the radioactive labelling reagent joint to the antidigoxin antibody. A precipitating agent is added to the mixture to help the formation of a precipitate and thus separate the labelled digoxin taken up from the precipitate free digoxin. The liquid is separated from the precipitate formed and the residual radioactivity of the precipitate is measured [fr

  20. Evaluation of Serial Casting for Boys with Duchenne Muscular Dystrophy: A Case Report.

    Science.gov (United States)

    Carroll, Kate; de Valle, Katy; Kornberg, Andrew; Ryan, Monique; Kennedy, Rachel

    2018-02-01

    To report the effects of below-knee serial casting in two boys with Duchenne muscular dystrophy who presented with well-preserved strength and calf shortening. Bilateral below-knee serial casts were applied over two weeks with follow-up of daily stretching and wearing of customized night splints. Outcome measures were performed at baseline, 1, 3, 6, and 12 months post-casting. These included measures of calf length, leg strength, motor function, endurance, and spatio-temporal gait parameters. Both boys completed serial casting with gains in muscle length. No adverse effects on strength or motor function were observed over a 12-month follow-up period.

  1. Serum bicarbonate and dehydration severity in gastroenteritis

    OpenAIRE

    Narchi, H.

    1998-01-01

    The concentration of bicarbonate was measured in serum samples from 106 children with gastroenteritis and dehydration. A concentration less than 22 mmol/l was more common in children with severe dehydration, but the magnitude of bicarbonate reduction was not significantly different with increasing degrees of dehydration. Doctors should not rely on the serum bicarbonate concentration when assessing fluid deficit.



  2. Impact of Prolonged Blood Incubation and Extended Serum Storage at Room Temperature on the Human Serum Metabolome

    Directory of Open Access Journals (Sweden)

    Beate Kamlage

    2018-01-01

    Full Text Available Metabolomics is a powerful technology with broad applications in life science that, like other -omics approaches, requires high-quality samples to achieve reliable results and ensure reproducibility. Therefore, along with quality assurance, methods to assess sample quality regarding pre-analytical confounders are urgently needed. In this study, we analyzed the response of the human serum metabolome to pre-analytical variations comprising prolonged blood incubation and extended serum storage at room temperature by using gas chromatography-mass spectrometry (GC-MS and liquid chromatography-tandem mass spectrometry (LC-MS/MS -based metabolomics. We found that the prolonged incubation of blood results in a statistically significant 20% increase and 4% decrease of 225 tested serum metabolites. Extended serum storage affected 21% of the analyzed metabolites (14% increased, 7% decreased. Amino acids and nucleobases showed the highest percentage of changed metabolites in both confounding conditions, whereas lipids were remarkably stable. Interestingly, the amounts of taurine and O-phosphoethanolamine, which have both been discussed as biomarkers for various diseases, were 1.8- and 2.9-fold increased after 6 h of blood incubation. Since we found that both are more stable in ethylenediaminetetraacetic acid (EDTA blood, EDTA plasma should be the preferred metabolomics matrix.

  3. Official Reports: Inventions, useful models, industrial samples, product certificates

    International Nuclear Information System (INIS)

    1994-01-01

    This serial collection presents brief information on patents, useful models, industrial samples, product certificates and trade marks registered in Uzbekistan. They comprise different branches of human activities including peaceful uses of atomic energy. (A.A.D.)

  4. Official Reports: Inventions, useful models, industrial samples, product certificates

    International Nuclear Information System (INIS)

    1996-01-01

    This serial collection presents brief information on patents, useful models, industrial samples, product certificates and trade marks registered in Uzbekistan. They comprise different branches of human activities including peaceful uses of atomic energy. (A.A.D.)

  5. Official Reports: Inventions, useful models, industrial samples, product certificates

    International Nuclear Information System (INIS)

    1995-01-01

    This serial collection presents brief information on patents, useful models, industrial samples, product certificates and trade marks registered in Uzbekistan. They comprise different branches of human activities including peaceful uses of atomic energy. (A.A.D.)

  6. Iron and ADHD: Time to Move beyond Serum Ferritin Levels

    Science.gov (United States)

    Donfrancesco, Renato; Parisi, Pasquale; Vanacore, Nicola; Martines, Francesca; Sargentini, Vittorio; Cortese, Samuele

    2013-01-01

    Objective: (a) To compare serum ferritin levels in a sample of stimulant-naive children with ADHD and matched controls and (b) to assess the association of serum ferritin to ADHD symptoms severity, ADHD subtypes, and IQ. Method: The ADHD and the control groups included 101 and 93 children, respectively. Serum ferritin levels were determined with…

  7. Serial network simplifies the design of multiple microcomputer systems

    Energy Technology Data Exchange (ETDEWEB)

    Folkes, D.

    1981-01-01

    Recently there has been a lot of interest in developing network communication schemes for carrying digital data between locally distributed computing stations. Many of these schemes have focused on distributed networking techniques for data processing applications. These applications suggest the use of a serial, multipoint bus, where a number of remote intelligent units act as slaves to a central or host computer. Each slave would be serially addressable from the host and would perform required operations upon being addressed by the host. Based on an MK3873 single-chip microcomputer, the SCU 20 is designed to be such a remote slave device. The capabilities of the SCU 20 and its use in systems applications are examined.

  8. Serial murder in America: case studies of seven offenders.

    Science.gov (United States)

    Beasley, James O

    2004-01-01

    This article summarizes and compares information on seven interviewed serial killers in an ongoing project designed to study similarities and differences among these individuals. The aim of this article is to increase our collective knowledge of the dynamics of serial murder by examining the perpetrators' backgrounds, as well as the unique ways in which they view themselves and the world around them. Although qualitative interview research alone is not sufficient to fully understand such behavior, it is useful in many ways. Some of the information discussed based on the seven offenders interviewed is compared with broader epidemiological studies, and the strengths and limitations of each type of research are discussed. Published in 2004 by John Wiley & Sons, Ltd.

  9. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    Science.gov (United States)

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  10. Mindfulness facets, trait emotional intelligence, emotional distress, and multiple health behaviors: A serial two-mediator model.

    Science.gov (United States)

    Jacobs, Ingo; Wollny, Anna; Sim, Chu-Won; Horsch, Antje

    2016-06-01

    In the present study, we tested a serial mindfulness facets-trait emotional intelligence (TEI)-emotional distress-multiple health behaviors mediation model in a sample of N = 427 German-speaking occupational therapists. The mindfulness facets-TEI-emotional distress section of the mediation model revealed partial mediation for the mindfulness facets Act with awareness (Act/Aware) and Accept without judgment (Accept); inconsistent mediation was found for the Describe facet. The serial two-mediator model included three mediational pathways that may link each of the four mindfulness facets with multiple health behaviors. Eight out of 12 indirect effects reached significance and fully mediated the links between Act/Aware and Describe to multiple health behaviors; partial mediation was found for Accept. The mindfulness facet Observe was most relevant for multiple health behaviors, but its relation was not amenable to mediation. Implications of the findings will be discussed. © 2016 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  11. Selenium status of South Bohemia seniors characterized by INAA of blood serum

    International Nuclear Information System (INIS)

    Kvicala, J.; Zamrazil, V.; Nemecek, J.; Jiranek, J.

    2008-01-01

    To estimate the status of selenium in seniors of the South Bohemia region, Czech Republic, 481 serum samples from seniors living in 17 Asylum Houses for seniors in the age between 60 and 99 years were obtained. Samples were analyzed by instrumental neutron activation analysis with concurrent analysis of 4 reference materials for quality assurance. Average concentration of serum Se, arithmetic means in individual Asylum Houses, frequency distribution of serum Se concentrations as well as five years running monitoring of serum Se concentrations of one group of seniors proved selenium deficiency of the elderly population of the region South Bohemia. (author)

  12. Cognitive, emotional and social markers of serial murdering.

    Science.gov (United States)

    Angrilli, Alessandro; Sartori, Giuseppe; Donzella, Giovanna

    2013-01-01

    Although criminal psychopathy is starting to be relatively well described, our knowledge of the characteristics and scientific markers of serial murdering is still very poor. A serial killer who murdered more than five people, KT, was administered a battery of standardized tests aimed at measuring neuropsychological impairment and social/emotional cognition deficits. KT exhibited a striking dissociation between a high level of emotional detachment and a low score on the antisocial behavior scale on the Psychopathy Checklist-Revised (PCL-R). The Minnesota Multiphasic Personality Inventory-2 showed a normal pattern with the psychotic triad at borderline level. KT had a high intelligence score and showed almost no impairment in cognitive tests sensitive to frontal lobe dysfunction (Wisconsin Card Sorting Test, Theory of Mind, Tower of London, this latter evidenced a mild impairment in planning performance). In the tests on moral, emotional and social cognition, his patterns of response differed from matched controls and from past reports on criminal psychopaths as, unlike these individuals, KT exhibited normal recognition of fear and a relatively intact knowledge of moral rules but he was impaired in the recognition of anger, embarrassment and conventional social rules. The overall picture of KT suggests that serial killing may be closer to normality than psychopathy defined according to either the DSM IV or the PCL-R, and it would be characterized by a relatively spared moral cognition and selective deficits in social and emotional cognition domains.

  13. Evidence for spontaneous serial refreshing in verbal working memory?

    Science.gov (United States)

    Vergauwe, Evie; Langerock, Naomi; Cowan, Nelson

    2018-04-01

    Working memory (WM) keeps information temporarily accessible for ongoing cognition. One proposed mechanism to keep information active in WM is refreshing. This mechanism is assumed to operate by bringing memory items into the focus of attention, thereby serially refreshing the content of WM. We report two experiments in which we examine evidence for the spontaneous occurrence of serial refreshing in verbal WM. Participants had to remember series of red letters, while black probe letters were presented between these memory items, with each probe to be judged present in or absent from the list presented so far, as quickly as possible (i.e., the probe-span task). Response times to the probes were used to infer the status of the representations in WM and, in particular, to examine whether the content of the focus of attention changed over time, as would be expected if serial refreshing occurs spontaneously during inter-item pauses. In sharp contrast with this hypothesis, our results indicate that the last-presented memory item remained in the focus of attention during the inter-item pauses of the probe-span task. We discuss how these findings help to define the boundary conditions of spontaneous refreshing of verbal material in WM, and discuss implications for verbal WM maintenance and forgetting.

  14. Effect of Ramadan fasting on serum heat shock protein 70 and serum lipid profile.

    Science.gov (United States)

    Zare, A; Hajhashemi, M; Hassan, Z M; Zarrin, S; Pourpak, Z; Moin, M; Salarilak, S; Masudi, S; Shahabi, S

    2011-07-01

    Ramadan, the holy month for the Islamic world, is a period every year when food and fluid intake is restricted to the pre-sunrise and post-sunset hours. The aim of this study was to evaluate the effect of Ramadan fasting on the serum concentration of heat shock protein 70 (HSP70) and serum lipid profile in healthy men. A total of 32 male volunteers with a mean age of 28.5 (range 23-37) years were selected for the study. Blood samples were obtained one day prior to Ramadan and on the 3rd and 25th days of fasting. Serum HSP70, triglyceride (TG), cholesterol (Chol), low-density lipoprotein (LDL) and high-density lipoprotein (HDL), LDL/HDL and Chol/HDL ratios were investigated. It was observed that the mean concentrations of serum HSP70 and HDL on the 25th day of Ramadan were significantly higher than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels on the 3rd day of Ramadan was significantly higher than those recorded one day before Ramadan. Mean concentrations of serum TG, Chol, LDL, and LDL/HDL and Chol/HDL ratios on the 25th day of Ramadan were significantly lower than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels found on the 3rd day of Ramadan were also significantly lower than those recorded one day before Ramadan. Ramadan fasting increases serum HSP70 and improves serum lipid profile.

  15. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  16. Cross-domain interference costs during concurrent verbal and spatial serial memory tasks are asymmetric

    NARCIS (Netherlands)

    Morey, Candice C.; Mall, Jonathan T.

    2012-01-01

    Some evidence suggests that memory for serial order is domain-general. Evidence also points to asymmetries in interference between verbal and visual-spatial tasks. We confirm that concurrently remembering verbal and spatial serial lists provokes substantial interference compared with remembering a

  17. Clinical and preclinical validation of the serum free light chain assay: identification of the critical difference for optimized clinical use.

    Science.gov (United States)

    Hansen, Charlotte T; Münster, Anna-Marie; Nielsen, Lars; Pedersen, Per; Abildgaard, Niels

    2012-12-01

    The use of the assay for the measurements of free light chains in serum (sFLCs) is increasing. However, there are technical limitations that potentially affect the use in serial measurements. We need further knowledge on the standards of analytical precision, the utility of conventional population-based reference values and the critical difference (CD) between serial results required for significance. To answer these questions, the biological variation must be known. We determined the biological variation in healthy individuals and patients with plasma cell dyscrasia (PCD). We assessed the imprecision of the analysis in use from FreeLite™. We determined the reference interval (RI) in 170 healthy individuals. The biological variation is identical for healthy individuals and patients with PCD. The imprecision of the sFLC analysis cannot fulfil the desirable performance standards for a laboratory test, but are within the manufacturer's ±20% variation for quality control samples. RI showed a significant increase for κ FLC and κ/λ ratio with age, but not for λ. Critical difference was calculated to be 24% and 23% for κ and λ, respectively. We suggest the use of an age-dependent RI. When monitoring patients with PCD, their own former results are the best reference, and knowledge on CD is a valuable tool, which we describe for the first time. Also, it challenges the recently proposed International Myeloma Working Group 'paraprotein relapse criteria', recommending an increase of more than 25% in the involved FLC to indicate the need for initiation of retreatment. We recommend revision of this criterion. © 2012 John Wiley & Sons A/S.

  18. Serum insulin like growth factor-1 is associated with working memory, executive function and selective attention in a sample of healthy, fit older adults.

    Science.gov (United States)

    Bellar, D; Glickman, E L; Juvancic-Heltzel, J; Gunstad, J

    2011-03-31

    The present study examined the association between serum insulin like growth factor-1 (IGF-1) concentrations and cognitive function in a sample of healthy, fit older adults (age: 70.8±9.3 years, body mass index (BMI): 27.3±5.7). Participants reported to the laboratory and basic anthropometric data were collected, followed by a fasted blood draw to quantify serum IGF-1. Participants then underwent cognitive testing that included the Mini-Mental Status Exam (MMSE), Trail Making Test A and B, Ruff's 2 and 7 test of selective attention and Letter Number Sequencing. Results showed the participants were generally cognitively intact (MMSE 27.6±1.8). Significant partial correlations (controlled for age, gender and years of education) emerged between serum IGF-1 concentrations and the total (r=0.381, P=0.030) and longest trial (r=0.455, P=0.011) on Letter Number Sequencing. Similar partial correlations yielded significant relationships between serum IGF-1 and Ruff's Automatic Detection Errors (r=-0.495, P=0.006), Controlled Speed Errors (r=-0.598, P=0.002) and errors made on the Trial Making Test part B (r=-0.466, P=0.010). These findings suggest that fasting levels of serum IGF-1 are related to higher levels of cognitive performance in healthy older adults, including working memory, selective attention and executive function. Further work is needed to more clearly determine possible mechanisms. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  19. Serum Bone Resorption Markers after Parathyroidectomy for Renal Hyperparathyroidism: Correlation Analyses for the Cross-Linked N-telopeptide of Collagen I and Tartrate-Resistant Acid Phosphatase

    Directory of Open Access Journals (Sweden)

    Kuo-Chin Hung

    2012-01-01

    Full Text Available Patients on long-term dialysis may develop secondary hyperparathyroidism (SHPT with increased serum concentrations of bone resorption markers such as the cross-linked N-telopeptide of type I collagen (NTX and type-5b tartrate-resistant acid phosphatase (TRAP. When SHPT proves refractory to treatment, parathyroidectomy (PTX may be needed. Renal patients on maintenance HD who received PTX for refractory SHPT (n=23 or who did not develop refractory SHPT (control subjects; n=25 were followed prospectively for 4 weeks. Serum intact parathyroid hormone (iPTH, NTX, TRAP, and bone alkaline phosphatase (BAP concentrations were measured serially and correlation analyses were performed. iPTH values decreased rapidly and dramatically. BAP values increased progressively with peak increases observed at 2 weeks after surgery. NTX and TRAP values decreased concurrently and progressively through 4 weeks following PTX. A significant correlation between TRAP and NTX values was observed before PTX but not at 4 weeks after PTX. Additionally, the fractional changes in serum TRAP were larger than those in serum NTX at all times examined after PTX. Serum iPTH, TRAP, and NTX values declined rapidly following PTX for SHPT. Serum TRAP values declined to greater degrees than serum NTX values throughout the 4-week period following PTX.

  20. Feasibility of shortening isolation of TB-suspects by first-sample PCR

    DEFF Research Database (Denmark)

    Fløe, Andreas; Wejse, Christian; Thomsen, Vibeke Østergaard

    Rationale: Isolation of patients suspected for tuberculosis (TB) is usually guided by serial sputum smears. Many of patients initially isolated will turn out not to have TB, or will not be regarded as contagious. Current standards imply isolation for hours or days until contagiousness has been...... excluded. Objective: To evaluate the utility of single-specimen polymerase chain-reaction (PCR) for Mycobacterium tuberculosis complex (MTBC) as a parameter to cease isolation when negative. Methods: We evaluated all patients in Denmark who had sputa investigated for MTBC at the National Reference......-positive on the sample that produced the PCR-negative result. Conclusion: Though adequate sensitivity in diagnosing TB still requires serial samples for microbiological examination, the question of isolation can be determined by first-sample PCR in the majority of cases, when the test is negative. In our study, less...

  1. Effect of storage duration on cytokine stability in human serum and plasma.

    Science.gov (United States)

    Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James

    2018-06-14

    Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix.

    Science.gov (United States)

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-11-30

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.

  3. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    International Nuclear Information System (INIS)

    Schuettler, J.; White, P.F.

    1984-01-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories

  4. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, J.; White, P.F.

    1984-09-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.

  5. Serum Matrix Metalloproteinase-3 as a Noninvasive Biomarker of Histological Synovitis for Diagnosis of Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Jian-Da Ma

    2014-01-01

    Full Text Available Objective. To explore the correlation between matrix metalloproteinase- (MMP- 3 and histological synovitis in rheumatoid arthritis (RA. Methods. Serum MMP-3 of 62 patients with active RA was detected by ELISA. Serial synovial tissue sections from all RA patients, 13 osteoarthritis, and 10 orthopedic arthropathies patients were stained with hematoxylin and eosin and immunohistochemically for MMP-3, CD3, CD20, CD38, CD68, and CD15. Results. The percentage of lining MMP3+ cells was significantly higher in RA patients especially with high grade synovitis and it was significantly correlated with Krenn’s synovitis score r=0.574, P<0.001 and sublining inflammatory cells. Multivariate stepwise linear regression analysis revealed that the association of the percentage of lining MMP3+ cells with activation of synovial stroma, sublining CD68+ macrophages, and CD15+ neutrophils was stronger than other histological indicators. The percentage of lining MMP3+ cells was significantly correlated with serum MMP-3 in RA r=0.656, P<0.001. Serum MMP-3 was higher in RA patients with high grade synovitis than that of low grade synovitis and significantly correlated with synovitis score and activation of synovial stroma subscore (all P<0.05. Conclusion. Serum MMP-3 may be an alternative noninvasive biomarker of histological synovitis and RA diagnosis.

  6. The attention-weighted sample-size model of visual short-term memory

    DEFF Research Database (Denmark)

    Smith, Philip L.; Lilburn, Simon D.; Corbett, Elaine A.

    2016-01-01

    exceeded that predicted by the sample-size model for both simultaneously and sequentially presented stimuli. Instead, the set-size effect and the serial position curves with sequential presentation were predicted by an attention-weighted version of the sample-size model, which assumes that one of the items...

  7. Influence of the collection tube on metabolomic changes in serum and plasma.

    Science.gov (United States)

    López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D

    2016-04-01

    Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Identification of Bodies by Unique Serial Numbers on Implanted Medical Devices.

    Science.gov (United States)

    Blessing, Melissa M; Lin, Peter T

    2018-05-01

    Visual identification is the most common identification method used by medical examiners but is not always possible. Alternative methods include X-ray, fingerprint, or DNA comparison, but these methods require additional resources. Comparison of serial numbers on implanted medical devices is a rapid and definitive method of identification. To assess the practicality of using this method, we reviewed 608 consecutive forensic autopsies performed at a regional medical examiner office. Of these, 56 cases required an alternative method of identification due to decomposition (n = 35), gunshot wound (n = 9), blunt trauma (n = 6), or charring (n = 6). Of these 56 cases, eight (14.3%) were known to have an implanted medical device. Of these eight cases, five (63%) could be positively identified by comparing serial numbers. If an implanted medical device is known to be present, and medical records are available, identification by medical device serial number should be a first-line method. © 2017 American Academy of Forensic Sciences.

  9. Serial casting for elbow flexion contractures in neonatal brachial plexus palsy.

    Science.gov (United States)

    Duijnisveld, B J; Steenbeek, D; Nelissen, R G H H

    2016-09-02

    The objective of this study was to evaluate the effectiveness of serial casting of elbow flexion contractures in neonatal brachial plexus palsy. A prospective consecutive cohort study was performed with a median follow-up of 5 years. Forty-one patients with elbow flexion contractures ≥ 30° were treated with serial casting until the contracture was ≤ 10°, for a maximum of 8 weeks. Range of motion, number of recurrences and patient satisfaction were recorded and analyzed using Wilcoxon signed-rank and Cox regression tests. Passive extension increased from a median of -40° (IQR -50 to -30) to -15° (IQR -10 to -20, p casting had to be prematurely replaced by night splinting due to complaints. Serial casting improved elbow flexion contractures, although recurrences were frequent. The severity of elbow flexion contracture is a predictor of recurrence. We recommend more research on muscle degeneration and determinants involved in elbow flexion contractures to improve treatment strategies and prevent side-effects.

  10. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  11. A study of serum lipid profile and serum apolipoproteins A1 and B in Indian male violent criminal offenders.

    Science.gov (United States)

    Chakrabarti, Nandini; Sinha, V K

    2006-01-01

    High cholesterol has been advanced as the most important factor in the development of coronary artery disease. Most panels have recommended population-wide dietary restrictions, yet a body of evolving data yields evidence of the hazards of low cholesterol, including links to aggression and hostility. The aim of this study was to compare the serum lipid profile and serum apolipoproteins A1 and B of men with a violent criminal record and men with no criminal history. Fasting blood samples were collected from 30 men with a known history of violent crime and 30 men with no criminal record. Serum lipid profile and serum apolipoproteins A1 and B were measured in each sample, and compared between the two groups. The group with the violent criminal record showed significantly lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B compared with the control group. Lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B could predispose to violence. Future research might explore the possibility that diets offered in prison could affect relevant pathways in lipid metabolism. Copyright (c) 2006 John Wiley & Sons, Ltd.

  12. Organic cattle products: Authenticating production origin by analysis of serum mineral content.

    Science.gov (United States)

    Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta

    2018-10-30

    An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Clinical and biochemical assessment of high serum vitamin B12 levels

    DEFF Research Database (Denmark)

    Arendt, Johan Frederik Berg; Nexø, Ebba

    2012-01-01

    Introduction: Measurement of serum cobalamin (Cbl) is routinely used to assess suspected Cbl deficiency. Surprisingly, 15% of all samples analysed for serum Cbl show values above the reference range of 200-600 pmol/L. Aim: We hypothesized that increased Cbl levels are caused by alterations...... in the circulating Cbl binding proteins haptocorrin (HC) and/or transcobalamin (TC), and that such changes may be of clinical importance. Materials and methods: We collected 834 blood samples from hospital treated patients with serum Cbl levels: 1000 pmol/L. In-house ELISAs were used...

  14. Laparoscopic Technique for Serial Collection of Para-Colonic, Left Colic, and Inferior Mesenteric Lymph Nodes in Macaques.

    Directory of Open Access Journals (Sweden)

    Jeremy Smedley

    Full Text Available Unlike peripheral lymph nodes (PLN, the mesenteric lymph nodes (MLN draining the gastrointestinal (GI tract are exposed to microbes and microbial products from the intestines and as such, are immunologically distinct. GI draining (MLN have also been shown to be sites of early viral replication and likely impact early events that determine the course of HIV infection. They also are important reservoir sites that harbor latently-infected cells and from which the virus can emerge even after prolonged combination antiretroviral therapy (cART. Changes in the microbial flora and increased permeability of the GI epithelium associated with lentiviral infection can impact the gut associated lymphoid tissue (GALT and induce changes to secondary lymphoid organs limiting immune reconstitution with cART. Nonhuman primate models for AIDS closely model HIV infection in humans and serial sampling of the GALT and associated secondary lymphoid organs in this model is crucial to gain a better understanding of the critical early events in infection, pathogenesis, and the role of immune responses or drugs in controlling virus at these sites. However, current techniques to sample GI draining (MLN involve major surgery and/or necropsy, which have, to date, limited the ability to investigate mechanisms mediating the initiation, persistence and control of infection in this compartment. Here, we describe a minimally invasive laparoscopic technique for serial sampling of these sites that can be used with increased sampling frequency, yields greater cell numbers and immune cell subsets than current non-invasive techniques of the GALT and reduces the potential for surgical complications that could complicate interpretation of the results. This procedure has potential to facilitate studies of pathogenesis and evaluation of preventive and treatment interventions, reducing sampling variables that can influence experimental results, and improving animal welfare.

  15. Fecal corticosterone reflects serum corticosterone in Florida sandhill cranes.

    Science.gov (United States)

    Ludders, J W; Langenberg, J A; Czekala, N M; Erb, H N

    2001-07-01

    Florida sandhill cranes (Grus canadensis pratensis) were conditioned to confinement 6 hr/day for 7 days. On day 8, each bird's jugular vein was catheterized, blood samples were drawn, and each crane was confined for 6 hr. Using a randomized, restricted cross-over design, cranes were injected intravenously with either 0.9% NaCl solution or ACTH (cosyntropin; Cortrosyn; 0.25 mg). During the 6 hr of confinement, fecal samples (feces and urine) were collected from each of five cranes immediately after defecation. Individual fecal samples were collected approximately at hourly intervals and assayed for corticosterone. We showed previously that serum corticosterone did not vary significantly following saline injection, but peaked significantly 60 min after ACTH injection. Maximal fecal corticosterone concentrations (ng/g) were greater (P cranes under controlled conditions, fecal corticosterone concentration reflects serum corticosterone levels, fecal corticosterone, Grus canadensis pratensis, sandhill cranes, serum corticosterone levels.

  16. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  17. Smart grid communication comparison: Distributed control middleware and serialization comparison for the Internet of Things

    DEFF Research Database (Denmark)

    Petersen, Bo Søborg; Bindner, Henrik W.; Poulsen, Bjarne

    2017-01-01

    To solve the problems caused by intermittent renewable energy production, communication between Distributed Energy Resources (DERs) and system operators is necessary. The communication middleware and serialization used for communication are essential to ensure delivery of the messages within...... communication middleware and serialization format/library, aided by the authors' earlier work, which investigates the performance and characteristics of communication middleware and serialization independently. Given the performance criteria of the paper, ZeroMQ, YAMI4, and ICE are the middleware that performs...

  18. Test amnioinfusion to determine suitability for serial therapeutic amnioinfusion in midtrimester premature rupture of membranes.

    Science.gov (United States)

    Tan, L-K; Kumar, S; Jolly, M; Gleeson, C; Johnson, P; Fisk, N M

    2003-01-01

    To evaluate whether a test amnioinfusion procedure is useful in selecting cases of midtrimester preterm premature rupture of membranes (PPROM) which may benefit from serial amnioinfusions if the initial fluid is retained. The Centre for Fetal Care database between 1992 and 2000 was reviewed for women with PPROM amnioinfusion. Amniotic fluid index (AFI) was assessed before and after a test amnioinfusion procedure. Those who retained fluid > or =48 h underwent serial AFI assessment with a view to serial amnioinfusion when oligohydramnios recurred. Eighty-five amnioinfusion procedures were performed in 60 women with oligohydramnios. Nineteen of these women presented with confirmed PPROM at a median gestation of 19 (range 15-22) weeks and severe olighohydramnios (median AFI 1, range 0-3 cm), in whom 20 test amnioinfusions were carried out. Two amnioinfusions were abandoned during the procedure because of fetal bradycardia and both mothers opted for termination of pregnancy. Only 4 women retained fluid during the test amnioinfusion, 1 of whom miscarried at 19 weeks before serial amnioinfusion could be started. The remaining 3 underwent a median of 4 (range 1-6) serial amnioinfusion procedures; none had evidence of pulmonary hypoplasia. Thirteen (68%) leaked fluid within 48 h; within this group there was 1 subsequent miscarriage and 9 pregnancy terminations. The remaining 3 pregnancies resulted in livebirths 2 of which had pulmonary hypoplasia with 1 early neonatal death. Overall survival was poor (4/19), largely attributed to the high incidence of terminations in the presence of persistent severe oligohydramnios. In continuing pregnancies reaching viability survival was 67% (4 of 6). Three quarters of women with mid-trimester PPROM lose fluid at test amnioinfusion and therefore would not be suitable candidates for serial amnioinfusion. However, if infused fluid is retained, this allows subsequent serial amnioinfusion and prolongation of pregnancy in about 75%, with an

  19. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix

    OpenAIRE

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-01-01

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The ...

  20. The motivation behind serial sexual homicide: is it sex, power, and control, or anger?

    Science.gov (United States)

    Myers, Wade C; Husted, David S; Safarik, Mark E; O'Toole, Mary Ellen

    2006-07-01

    Controversy exists in the literature and society regarding what motivates serial sexual killers to commit their crimes. Hypotheses range from the seeking of sexual gratification to the achievement of power and control to the expression of anger. The authors provide theoretical, empirical, evolutionary, and physiological support for the argument that serial sexual murderers above all commit their crimes in pursuit of sadistic pleasure. The seeking of power and control over victims is believed to serve the two secondary purposes of heightening sexual arousal and ensuring victim presence for the crime. Anger is not considered a key component of these offenders' motivation due to its inhibitory physiological effect on sexual functioning. On the contrary, criminal investigations into serial sexual killings consistently reveal erotically charged crimes, with sexual motivation expressed either overtly or symbolically. Although anger may be correlated with serial sexual homicide offenders, as it is with criminal offenders in general, it is not causative. The authors further believe serial sexual murderers should be considered sex offenders. A significant proportion of them appear to have paraphilic disorders within the spectrum of sexual sadism. "sexual sadism, homicidal type" is proposed as a diagnostic subtype of sexual sadism applicable to many of these offenders, and a suggested modification of DSM criteria is presented.