WorldWideScience

Sample records for serial endomyocardial biopsies

  1. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  2. Gallium-67 imaging in human heart transplantation: correlation with endomyocardial biopsy

    International Nuclear Information System (INIS)

    Meneguetti, J.C.; Camargo, E.E.; Soares, J. Jr.

    1987-01-01

    Endomyocardial biopsy seems to be the most accurate method to use for diagnosis and follow-up of acute rejection of the transplanted heart. This investigation compared a noninvasive procedure, gallium-67 imaging, with endomyocardial biopsy in the detection of acute rejection in heart transplantation. Seven male patients (aged 41 to 54 years) sequentially had 46 gallium-67 scintigrams and 46 endomyocardial biopsies between 1 week and 8 months after transplantation. Both studies were obtained in the same day, 48 hours after the administration of an intravenous injection of gallium-67 citrate. Cardiac uptake was graded as negative, mild, moderate, and marked according to an increasing count ratio with rib and sternal uptakes. Histologic findings were graded as negative, mild acute rejection, moderate acute rejection, severe acute rejection, resolving rejection, and nonspecific reaction. Negative biopsies were not found with moderate uptake, and neither moderate nor severe acute rejection were found with negative scintigrams. Imaging sensitivity was 83% with 17% false negatives and 9% false positives. Of seven studies with moderate uptake, five showed moderate acute rejection, and the patients had specific therapy with a decline in uptake, which correlated with resolving rejection. It is conceivable that in the future this technique may be used as a screening procedure for sequential endomyocardial biopsies in the follow-up of heart transplant patients

  3. Cardiac toxoplasmosis after heart transplantation diagnosed by endomyocardial biopsy.

    Science.gov (United States)

    Petty, L A; Qamar, S; Ananthanarayanan, V; Husain, A N; Murks, C; Potter, L; Kim, G; Pursell, K; Fedson, S

    2015-10-01

    We describe a case of cardiac toxoplasmosis diagnosed by routine endomyocardial biopsy in a patient with trimethoprim-sulfamethoxazole (TMP-SMX) intolerance on atovaquone prophylaxis. Data are not available on the efficacy of atovaquone as Toxoplasma gondii prophylaxis after heart transplantation. In heart transplant patients in whom TMP-SMX is not an option, other strategies may be considered, including the addition of pyrimethamine to atovaquone. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies: An in-vitro study.

    Science.gov (United States)

    Lossnitzer, Dirk; Seitz, Sebastian A; Krautz, Birgit; Schnackenburg, Bernhard; André, Florian; Korosoglou, Grigorios; Katus, Hugo A; Steen, Henning

    2015-07-26

    To investigate if magnetic resonance (MR)-guided biopsy can improve the performance and safety of such procedures. A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging (MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance (imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists. MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies.

  5. Right atrial and right ventricular ultrasound-guided biopsy technique in standing horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; Ven, S; van der Vekens, N; Chiers, K; van Loon, G

    2016-05-01

    Endomyocardial biopsies could be a valuable tool in equine cardiology for diagnosing myocardial disease, which is probably underdiagnosed in horses because of lack of specific diagnostic measures and limitations of currently available diagnostic methods. To describe a technique for serial right atrial and right ventricular endomyocardial biopsy in standing horses using a percutaneous approach through the jugular vein. Prospective study. Biopsy was performed in 10 healthy standing horses sedated with detomidine, under continuous electrocardiography monitoring. A 10 cm (n = 6), 45 cm (n = 1) or 98 cm (n = 3) introducer sheath was inserted into the right jugular vein. Under echocardiographic guidance, a biopsy forceps was introduced through the sheath into the right ventricle and right atrium and endomyocardial biopsies were acquired. In all horses, 3 right ventricular biopsies were obtained from the right ventricular apex and 3 right atrial biopsies were obtained from the dorsal right atrial wall near the tuberculum intervenosum. The presence of myocardial tissue was confirmed by histology. All horses showed atrial and ventricular premature depolarisations associated with acquisition of the biopsies. In 9 horses, the arrhythmia disappeared after retraction of the forceps and introducer sheath. In one horse, ventricular premature depolarisations disappeared only after 8 h. No other complications were observed. Endomyocardial biopsy of the right atrium and right ventricle could be performed in standing horses using a percutaneous approach through the jugular vein and was not associated with complications other than temporary arrhythmias. This technique may be useful for research purposes or as a diagnostic tool, although further research is needed to establish the safety of the technique in clinical patients with myocardial disease. © 2015 EVJ Ltd.

  6. Do clinical diagnoses correlate with pathological diagnoses in cardiac transplant patients? The importance of endomyocardial biopsy

    DEFF Research Database (Denmark)

    Luk, Adriana; Metawee, Mohammed; Ahn, Eric

    2009-01-01

    . Patient records were reviewed for preoperative clinical diagnoses and other relevant data, including pretransplant endomyocardial biopsy (EMB) results, information regarding left ventricular assist devices and, finally, evidence of disease recurrence in the grafted heart. RESULTS: A shift...... diagnose patients with diseases such as sarcoidosis, amyloidosis and particular types of myocarditis because these can readily recur in the grafted heart. The risk for recurrence must be known to practitioners and, most importantly, to the patient. We strongly recommend the use of EMB if a nonischemic...

  7. Gallium-67 imaging in patients with dilated cardiomyopathy and biopsy-proven myocarditis

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.; Subramanian, R.; Scanlon, P.J.; Gunnar, R.M.

    1984-01-01

    Current standards for detection of myocarditis in a clinical setting rely on endomyocardial biopsy for accurate diagnosis. With this technique a subset of patients with dilated cardiomyopathy show unsuspected myocarditis histologically. Endomyocardial biopsy, despite its specificity, may lack sensitivity due to sampling error if the inflammation is patchy or focal. Therefore, inflammation-sensitive radioisotopic imaging may be a useful adjunct in the diagnosis of myocarditis. This study was designed to evaluate the applicability of gallium-67 (67Ga) myocardial imaging as an adjunct to endomyocardial biopsy in the diagnosis of myocarditis. Sixty-eight consecutive patients referred for evaluation of dilated cardiomyopathy underwent 71 parallel studies with 67Ga imaging and biopsies that served as the basis of comparison for this study. Histologic myocarditis was identified in 8% of biopsy specimens. Clinical and hemodynamic parameters could not be used to predict the presence of myocarditis. Five of six biopsy samples (87%) with myocarditis showed dense 67Ga uptake, whereas only nine of 65 negative biopsy samples (14%) were paired with equivocally positive 67Ga scans. The single patient with myocarditis and no myocardial 67Ga uptake had dense mediastinal lymph node uptake that may have obscured cardiac uptake. The incidence of myocarditis on biopsy with a positive 67Ga scan was 36% (5/14); however, the incidence of myocarditis with a negative 67Ga scan was only 1.8% (1/57). Follow-up scans for three patients showed close correlation of 67Ga uptake with myocarditis on biopsy. In conclusion 67Ga may be a useful screening test for identifying patients with a high yield of myocarditis on biopsy, and serial scans may eliminate the need for frequent biopsies in patients with proven myocarditis

  8. Clinical studies on diabetic myocardial disease using exercise testing with myocardial scintigraphy and endomyocardial biopsy

    International Nuclear Information System (INIS)

    Genda, A.; Mizuno, S.; Nunoda, S.

    1986-01-01

    Nine diabetics without significant coronary stenosis participated in an exercise testing protocol with thallium-201 myocardial scintigraphy. Endomyocardial biopsy of right ventricle was also obtained. There were 4 patients with abnormal perfusion (positive group) and 5 patients with normal perfusion (negative group). All cases of the positive group were familial diabetics and there was only one case of dietary treatment, whereas in the negative group, there were only 2 cases of familial diabetics and 3 cases receiving dietary treatment. No statistical differences between the positive and negative groups were observed for the data of exercise performance and hemodynamic parameters in cardiac catheterization at rest. However, the mean ejection fraction in the positive group (62 +/- 13%) was significantly lower than in the negative group (77 +/- 4%). In both groups, the mean diameter of myocardial cells and the mean percent fibrosis of biopsy specimens showed significant increases compared with the control group. The mean percent fibrosis in the positive group (24.1 +/- 8.5%) compared with that in the negative group (16.5 +/- 5.9%) showed a tendency to increase. It is suggested that the abnormal perfusion of thallium-201 in the positive group indicates subclinically a pathological change of microcirculation caused by diabetes mellitus

  9. A novel technique of serial biopsy in mouse brain tumour models.

    Directory of Open Access Journals (Sweden)

    Sasha Rogers

    Full Text Available Biopsy is often used to investigate brain tumour-specific abnormalities so that treatments can be appropriately tailored. Dacomitinib (PF-00299804 is a tyrosine kinase inhibitor (TKI, which is predicted to only be effective in cancers where the targets of this drug (EGFR, ERBB2, ERBB4 are abnormally active. Here we describe a method by which serial biopsy can be used to validate response to dacomitinib treatment in vivo using a mouse glioblastoma model. In order to determine the feasibility of conducting serial brain biopsies in mouse models with minimal morbidity, and if successful, investigate whether this can facilitate evaluation of chemotherapeutic response, an orthotopic model of glioblastoma was used. Immunodeficient mice received cortical implants of the human glioblastoma cell line, U87MG, modified to express the constitutively-active EGFR mutant, EGFRvIII, GFP and luciferase. Tumour growth was monitored using bioluminescence imaging. Upon attainment of a moderate tumour size, free-hand biopsy was performed on a subgroup of animals. Animal monitoring using a neurological severity score (NSS showed that all mice survived the procedure with minimal perioperative morbidity and recovered to similar levels as controls over a period of five days. The technique was used to evaluate dacomitinib-mediated inhibition of EGFRvIII two hours after drug administration. We show that serial tissue samples can be obtained, that the samples retain histological features of the tumour, and are of sufficient quality to determine response to treatment. This approach represents a significant advance in murine brain surgery that may be applicable to other brain tumour models. Importantly, the methodology has the potential to accelerate the preclinical in vivo drug screening process.

  10. [Endomyocardial fibrosis with massive calcification of the left ventricle].

    Science.gov (United States)

    Trigo, Joana; Camacho, Ana; Gago, Paula; Candeias, Rui; Santos, Walter; Marques, Nuno; Matos, Pedro; Brandão, Victor; Gomes, Veloso

    2010-03-01

    Endomyocardial fibrosis is a rare disease, endemic in tropical countries. It is characterized by fibrosis of the endocardium that can extend to myocardium. Important calcification of the endocardium is rare with only a few cases reported in the literature. We report a case of endomyocardial fibrosis in a european caucasian patient, associated with massive calcification of left ventricle.

  11. Serial superficial digital flexor tendon biopsies for diagnosing and monitoring collagenase-induced tendonitis in horses

    Directory of Open Access Journals (Sweden)

    José C. de Lacerda Neto

    2013-06-01

    Full Text Available The purpose of this investigation was to demonstrate the feasibility of a biopsy technique by performing serial evaluations of tissue samples of the forelimb superficial digital flexor tendon (SDFT in healthy horses and in horses subjected to superficial digital flexor tendonitis induction. Eight adult horses were evaluated in two different phases (P, control (P1 and tendonitis-induced (P2. At P1, the horses were subjected to five SDFT biopsies of the left forelimb, with 24 hours (h of interval. Clinical and ultrasonographic (US examinations were performed immediately before the tendonitis induction, 24 and 48 h after the procedure. The biopsied tendon tissues were analyzed through histology. P2 evaluations were carried out three months later, when the same horses were subjected to tendonitis induction by injection of bacterial collagenase into the right forelimb SDFT. P2 clinical and US evaluations, and SDFT biopsies were performed before, and after injury induction at the following time intervals: after 24, 48, 72 and 96 h, and after 15, 30, 60, 90, 120 and 150 days. The biopsy technique has proven to be easy and quick to perform and yielded good tendon samples for histological evaluation. At P1 the horses did not show signs of localised inflammation, pain or lameness, neither SDFT US alterations after biopsies, showing that the biopsy procedure per se did not risk tendon integrity. Therefore, this procedure is feasible for routine tendon histological evaluations. The P2 findings demonstrate a relation between the US and histology evaluations concerning induced tendonitis evolution. However, the clinical signs of tendonitis poorly reflected the microscopic tissue condition, indicating that clinical presentation is not a reliable parameter for monitoring injury development. The presented method of biopsying SDFT tissue in horses enables the serial collection of material for histological analysis causing no clinical signs and tendon damage seen

  12. Right Ventricular Endomyocardial Fibrosis Presenting With Ventricular Tachycardia And Apical Thrombus - An Interesting Presentation

    Directory of Open Access Journals (Sweden)

    Amitesh Aggarwal

    2009-11-01

    Full Text Available Endomyocardial fibrosis is a progressive disease of unknown origin affecting children and young adults. It involves inflow portion of right and/or left ventricle and apex. It may be associated with thrombus. Literature regarding right ventricular endomyocardial fibrosis with thrombus is scarce. Here we report a rare case of right ventricular endomyocardial fibrosis presenting as ventricular tachycardia and echocardiographic evidence of apical thrombus. Interestingly there was no pulmonary involvement or evidence of deep venous thrombosis. This case also underscores the importance of urgent echocardiography in diagnosis of obscure cases of ventricular tachycardia.

  13. Endomyocardial fibrosis associated with massive calcification of the left ventricle

    Directory of Open Access Journals (Sweden)

    Canesin Manoel Fernandes

    1999-01-01

    Full Text Available This is the report of a rare case of endomyocardial fibrosis associated with massive calcification of the left ventricle in a male patient with dyspnea on great exertion, which began 5 years earlier and rapidly evolved. Due to lack of information and the absence of clinical signs that could characterize impairment of other organs, the case was initially managed as a disease with a pulmonary origin. With the evolution of the disease and in the presence of radiological images of heterogeneous opacification in the projection of the left ventricle, the diagnostic hypothesis of endomyocardial disease was established. This hypothesis was later confirmed on chest computed tomography. The patient died on the 16th day of the hospital stay, probably because of lack of myocardial reserve, with clinical findings of refractory heart failure, possibly aggravated by pulmonary infection. This shows that a rare disease such as endomyocardial fibrosis associated with massive calcification of the left ventricle may be suspected on a simple chest X-ray and confirmed by computed tomography.

  14. Clinical Meaning of Ascites in Patients with Endomyocardial Fibrosis

    Directory of Open Access Journals (Sweden)

    Barretto Antonio Carlos Pereira

    2002-01-01

    Full Text Available OBJECTIVE: To evaluate the clinical meaning of ascites and the main features of patients with ascites and endomyocardial fibrosis. METHODS: We studied 166 patients with endomyocardial fibrosis (mean age 37 years, 114 women treated over the last 20 years. Ventriculography findings, surgery or necropsy confirmed the diagnosis in all patients. Most patients belonged to New York Heart Association Functional Class III/IV (134, 83.7%. Eighty-one (50.6% had biventricular, 28 (17.5% had right ventricular, and 51 (31.8% had left ventricular involvement. During follow-up, 56 patients died. RESULTS: Ascites was present in 67 (41.8% patients, and right ventricular involvement was present in 59 (88%. In the comparison between patients with or without ascites, those with ascites had higher mortality (49.2% and 24.7%, respectively. Patients with ascites had a higher incidence of edema (95% vs. 43%, hepatomegaly (5.8cm vs. 4.1cm, mean right atrium pressure (19.3 vs. 12mmHg, and final right ventricle diastolic pressure (18.7 vs. 12.9mmHg. Also, patients with ascites had a longer history of illness (5.1 and 3.9 years, respectively and had atrial fibrillation more frequently (44.7% vs. 30.1%. CONCLUSION: Ascites was observed in less than 50% of cases of endomyocardial fibrosis and was associated with greater involvement of the right ventricle and with a longer duration of the disease, thus being a characteristic of a worse prognosis.

  15. Endomyocardial fibrosis in infancy

    Directory of Open Access Journals (Sweden)

    Jatene Marcelo Biscegli

    2003-01-01

    Full Text Available The patient was a 4-month-old infant, who underwent persistent ductus arteriosus interruption with titanium clips at the age of 13 days and, since the age of 2 months, had crises of hypoxia and hypertonicity. After clinical investigation, the presence of pulmonary hypertension was confirmed and left ventricular inflow tract obstruction was suspected. The patient underwent surgical treatment at the age of 4 months, during which right and left ventricular endocardial fibrosis was identified. The fibrosis was resected, but the infant had an unfavorable clinical evolution with significant diastolic restriction and died on the sixth postoperative day. Anatomicopathological and surgical findings suggested endomyocardial fibrosis, although that pathology is very rare at the patient's age.

  16. Endomyocardial Fibrosis in Northern Nigerian Girl | Aliyu | Annals of ...

    African Journals Online (AJOL)

    Endomyocardial fibrosis (EMF) is a disease of the tropics and subtropics; and the most common cause of restrictive cardiomyopathy. In Nigeria, it is more common in the rain forest zone; though few case reports have been documented in the Northern part of Nigeria; it is often more common amongst adolescents and young ...

  17. Prediction of acute cardiac rejection using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Bonioszczuk, J.; Cooper, D.K.C.; Isaacs, S.; Rose, A.G.; Smith, J.A.; Uys, C.J.; Barnard, C.N.; Fraser, R.

    1984-01-01

    Radionuclide scanning of the donor left ventricle using technetium-99m-labelled red cells was used to monitor acute rejection after heterotopic heart transplantation and compared with histopathological evidence of rejection obtained at examination of an endomyocardial biopsy specimen. The ejection fraction and end-diastolic, end-systolic and stroke volumes were calculated at each examination; an equation was derived from these data to predict the degree of acute rejection, using histopathological examination of endomyocardial biopsy specimens as criteria of the presence and severity of rejection. A highly significant multiple correlation between radionuclide scanning parameters and endomyocardial biopsy was found. The advantages of non-invasive radionuclide scanning over the invasive procedure of endomyocardial biopsy are discussed

  18. Diagnosis of cardiac allograft rejection with MR imaging

    International Nuclear Information System (INIS)

    Soulen, R.L.; Fraser, C.D.; Hutchins, G.M.; Baumgartner, W.A.; Reitz, B.A.

    1987-01-01

    Serial MR images and endomyocardial biopsy specimens of heterotopic cervical cardiac allotransplants were obtained in six dogs during 2 weeks of immunosuppression followed by 1 week without such therapy. A surface coil and gated spin-echo technique were used. Myocardial intensity (MI) measurements and histopathologic interpretations were performed independently. All six dogs showed a decrease in MI between their first and second MR studies, while showing no rejection. One dog had no rejection and died; in five dogs studies gated to every other beat showed progressive increase in MI that correlated significantly with increasing rejection, though absolute MI values did not correlated with a specific biopsy score. Severe rejection also caused overt increase in myocardial mass. The MI in the early postoperative period may reflect reperfusion injury. Absolute intensity values cannot predict rejection. Serial studies in transplant patients may prove clinically useful

  19. Psychological impact of serial prostate-specific antigen tests in Japanese men waiting for prostate biopsy.

    Science.gov (United States)

    Kobayashi, Minoru; Nukui, Akinori; Kamai, Takao

    2017-02-01

    It is common to repeat prostate-specific antigen (PSA) measurements for men with intermediate PSA elevation before prostate biopsy. In this scenario, men with persistently elevated PSA values may have considerable psychological distress. We attempted to determine whether elevated PSA values have psychological effects on these men in association with the timing of measurement, PSA kinetics, and biopsy results. In order to investigate the initial and late effects of PSA tests on psychological distress during serial measurements, two groups of men with screen-positive results (PSA ≥3 ng/ml) were studied-205 men whose first questionnaires regarding anxiety and depression were taken at initial screening (group A), and 103 men whose questionnaires were taken at repeated measurement for prior PSA elevation (group B). The level of distress was generally low. There were no significant differences in distress between the two groups, suggesting a constant psychological effect by elevated PSA values over a long period of time. The distress of men in group A increased significantly as PSA levels rose and decreased when they fell to normal range. On the other hand, the distress of men in group B did not change regardless of PSA kinetics, indicating that their psychological condition seemed susceptible to subtle PSA change only in the initial phase of measurements. Unexpectedly, men with benign results showed insignificant but higher distress after prostate biopsy. Although a small fraction of men have psychological distress caused by changes in PSA levels, the benefits, risks (psychological and physical), and limitations of PSA tests must be adequately explained to the patients before entering the screening program.

  20. Significance of left ventricular volume measurement after heart transplantation using radionuclide techniques

    International Nuclear Information System (INIS)

    Novitzky, D.; Cooper, D.; Boniaszczuk, J.

    1985-01-01

    Multigated equilibrium blood pool scanning using Technetium 99m labeled red blood cells was used to measure left ventricular volumes in three heterotopic and one orthotopic heart transplant recipient(s). Simultaneously, an endomyocardial biopsy was performed and the degree of acute rejection was assessed by a histological scoring system. The scores were correlated to changes in ejection fraction and heart rate. Technetium 99m scanning data were pooled according to the endomyocardial biopsy score: no rejection; mild rejection; moderate rejection, and severe rejection. In each group, the median of the left ventricular volume parameters was calculated and correlated with the endomyocardial biopsy score, using a non-parametric one-way analysis of variance. A decrease in stroke volume correlated best with the endomyocardial biopsy score during acute rejection. A decrease in end-diastolic left ventricular volumes did not correlate as well. Changes in the end-systolic left ventricular volumes were not statistically significant, but using a simple correlation between end-systolic left ventricular volumes and endomyocardial biopsy the correlation reached significance. Changes in left ventricular volumes measured by Technetium 99m scanning may be useful to confirm the presence or absence of acute rejection in patients with heart grafts

  1. The role of indium-111 antimyosin (Fab) imaging as a noninvasive surveillance method of human heart transplant rejection

    International Nuclear Information System (INIS)

    De Nardo, D.; Scibilia, G.; Macchiarelli, A.G.

    1989-01-01

    The identification of rejection after heart transplantation in patients receiving cyclosporine immunosuppressive therapy requires the endomyocardial biopsy, an invasive method associated with a finite morbidity. To evaluate the role of indium-111 antimyosin (Fab) scintigraphy as a noninvasive surveillance method of heart transplant rejection, the Fab fragment of murine monoclonal antimyosin antibodies labeled with indium-111 was administered intravenously in 30 scintigraphic studies to 10 consecutive heart transplant recipients. Endomyocardial biopsy specimens were obtained 72 hours after each scintigraphic study. Nineteen scintigraphic studies had negative findings; no false negative finding was obtained. Eleven antimyosin scintigraphic studies had positive findings, and in these studies endomyocardial biopsy revealed mild rejection in two cases, moderate acute rejection with myocyte necrosis in two cases, myocyte necrosis as a consequence of ischemic injury in six cases, and possibly cytotoxic damage in one case. Antimyosin scintigraphy may represent a reliable screening method for the surveillance of heart transplant patients. In the presence of a negative finding from antimyosin scintigraphy, it may be possible to avoid endomyocardial biopsy. Conversely, in patients who have a positive finding from antimyosin scintigraphy, the endomyocardial biopsy is mandatory to establish the definitive diagnosis by histologic examination of the myocardium

  2. Lyme carditis. Electrophysiologic and histopathologic study

    International Nuclear Information System (INIS)

    Reznick, J.W.; Braunstein, D.B.; Walsh, R.L.; Smith, C.R.; Wolfson, P.M.; Gierke, L.W.; Gorelkin, L.; Chandler, F.W.

    1986-01-01

    To further define the nature of Lyme carditis, electrophysiologic study and endomyocardial biopsy were performed in a patient with Lyme disease, whose principal cardiac manifestation was high-degree atrioventricular block. Intracardiac recording demonstrated supra-Hisian block and complete absence of an escape mechanism. Gallium 67 scanning demonstrated myocardial uptake, and right ventricular endomyocardial biopsy revealed active lymphocytic myocarditis. A structure compatible with a spirochetal organism was demonstrated in one biopsy specimen. It is concluded that Lyme disease can produce active myocarditis, as suggested by gallium 67 imaging and confirmed by endomyocardial biopsy. Furthermore, the presence of high-grade atrioventricular block in this disease requires aggressive management with temporary pacemaker and corticosteroid therapy

  3. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  4. Mitral valve disease with rheumatic appearance in the presence of left ventricular endomyocardial fibrosis

    Directory of Open Access Journals (Sweden)

    Lurildo R. Saraiva

    1999-03-01

    Full Text Available This is a report of a nine-year-old boy with both mitral stenosis and regurgitation and extensive endomyocardial fibrosis of the left ventricle. Focus is given to the singularity of the fibrotic process, with an emphasis on the etiopathogenic aspects.

  5. Correlation of 18F-fluoroethyl tyrosine positron-emission tomography uptake values and histomorphological findings by stereotactic serial biopsy in newly diagnosed brain tumors using a refined software tool

    Directory of Open Access Journals (Sweden)

    Lopez WO

    2015-12-01

    Full Text Available William Omar Contreras Lopez,1,2 Joacir Graciolli Cordeiro,1 Ulrich Albicker,3 Soroush Doostkam,4 Guido Nikkhah,1,5 Robert D Kirch,6 Michael Trippel,1 Thomas Reithmeier1,7 1Department of Stereotactic and Functional Neurosurgery, University Medical Center Freiburg, Freiburg im Breisgau, Germany; 2Division of Functional Neurosurgery, Department of Neurology, Hospital das Clinicas, University of São Paulo Medical School, São Paulo, Brazil; 3Inomed, Emmendingen, 4Department of Neuropathology, University Medical Center Freiburg, Freiburg im Breisgau, 5Department of Neurosurgery, University Clinic Erlangen, Erlangen, 6Neuroelectronic Systems, Department of Neurosurgery, University Medical Center Freiburg, Freiburg im Breisgau, 7Department of Neurosurgery, Schwabing Academic Teaching Hospital of Technical University and Ludwig Maximilian University of Munich, Munich, Germany Background: Magnetic resonance imaging (MRI is the standard neuroimaging method to diagnose neoplastic brain lesions, as well as to perform stereotactic biopsy surgical planning. MRI has the advantage of providing structural anatomical details with high sensitivity, though histological specificity is limited. Although combining MRI with other imaging modalities, such as positron-emission tomography (PET, has proven to increment specificity, exact correlation between PET threshold uptake ratios (URs and histological diagnosis and grading has not yet been described.Objectives: The aim of this study was to correlate exactly the histopathological criteria of the biopsy site to its PET uptake value with high spatial resolution (mm3, and to analyze the diagnostic value of PET using the amino acid O-(2-[18F]fluoroethyl-L-tyrosine (18F-FET PET in patients with newly diagnosed brain lesions in comparison to histological findings obtained from stereotactic serial biopsy.Patients and methods: A total of 23 adult patients with newly diagnosed brain tumors on MRI were enrolled in this study

  6. Complete atrioventricular block following radiation therapy for malignant thymoma

    International Nuclear Information System (INIS)

    Nakao, Takeshi; Kanaya, Honin; Namura, Masanobu; Ohsato, Kazuo; Araki, Tsutomu; Ohka, Takio; Sugihara, Norihiko; Takeda, Ryoyu.

    1990-01-01

    Complete atrioventricular block following radiation is very rare. We present a case which developed after radiation therapy for malignant thymoma. The etiology of conduction disturbances due to radiation is unknown. In our case, serial electrocardiograms showed stepwise progression of the conduction disturbance, and his bundle electrocardiograms revealed new prolongation of the H-V interval. Endomyocardial biopsy specimens demonstrated occlusion in small arteries and diffuse degenerative changes in the myocardium. We therefore attributed the complete atrioventricular block in our patient to secondary damage to the conduction system, caused by radiation-induced occlusive changes in the small arteries supplying the conduction system. (author)

  7. Imaging techniques for myocardial inflammation

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.

    1986-01-01

    Dilated cardiomyopathy (DC) represents a heterogeneous group of disorders which results in morbidity and mortality in young individuals. Recent evidence suggests that a subset of these patients have histologic evidence of myocarditis which is potentially treatable with immunosuppression. The identification of myocardial inflammation may therefore lead to development of therapeutic regimens designed to treat the cause rather than the effect of the myocardial disease. Ultimately, this may result in improvement in the abysmal prognosis of DC. The currently accepted technique for identification of active myocardial inflammation is endomyocardial biopsy. This technique is not perfect, however, since pathologic standards for the diagnosis of myocarditis have not been established. Furthermore, focal inflammation may give rise to sampling error. The inflammation-avid radioisotope gallium-67 citrate has been used as an adjunct to biopsy improving the yield of myocarditis from 7 percent to 36 percent. Serial imaging correlates well to biopsy results. Future studies are designed to study the applicability of lymphocyte labelling techniques to myocardial inflammatory disease

  8. Role of Soluble ST2 as a Marker for Rejection after Heart Transplant

    OpenAIRE

    Lee, Ga Yeon; Choi, Jin-Oh; Ju, Eun-Seon; Lee, Yoo-Jung; Jeon, Eun-Seok

    2016-01-01

    Background and Objectives Endomyocardial biopsy is obligatory during the first year after heart transplant (HTx) for the surveillance of acute rejection. Previous attempts using cardiac biomarkers for the detection of rejection failed to show enough evidence to substitute endomyocardial biopsy. Therefore, this study sought the possibility of using soluble ST2 (sST2), a novel cardiovascular marker, as a surrogate marker for acute allograft rejection after HTx. Subjects and Methods A total of 4...

  9. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  10. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  11. Role of Soluble ST2 as a Marker for Rejection after Heart Transplant.

    Science.gov (United States)

    Lee, Ga Yeon; Choi, Jin-Oh; Ju, Eun-Seon; Lee, Yoo-Jung; Jeon, Eun-Seok

    2016-11-01

    Endomyocardial biopsy is obligatory during the first year after heart transplant (HTx) for the surveillance of acute rejection. Previous attempts using cardiac biomarkers for the detection of rejection failed to show enough evidence to substitute endomyocardial biopsy. Therefore, this study sought the possibility of using soluble ST2 (sST2), a novel cardiovascular marker, as a surrogate marker for acute allograft rejection after HTx. A total of 494 blood samples acquired at the time of endomyocardial biopsy were analyzed in 67 HTx cases from September 2006 to August 2014. Significant rejection was defined as International Society of Heart and Lung Transplant (ISHLT) score ≥2R and humoral rejection accompanied by hemodynamic instability. Twenty cases of HTx with 22 blood samples showed significant rejection in endomyocardial biopsy at 4.0 (2.0-9.0) months after HTx. The level of sST2 showed positive correlation with cardiac troponin I, and N-terminal pro-B-type natriuretic peptide (all prejection) (p=0.003). However, when we studied within-subject effects of sST2 using a mixed model, the sST2 level according to the predefined time point was not different according to the presence of significant rejection (p for interaction=0.94). Although sST2 is known as a promising predictor for cardiovascular events, its role in HTx patients to predict acute allograft rejection seems to be limited.

  12. Studies on the clinical course of chronic hepatitis in the patients who underwent serial needle liver biopsies

    International Nuclear Information System (INIS)

    Hirata, Tetsuro

    1984-01-01

    In order to evaluate the changes in biochemical liver function tests and hepatic scintigraphic findings of chronic hepatitis, the author analyzed 35 patients who underwent serial liver biopsies. The results were summerized as follows: 1. Histological deteriorations in chronic hepatitis more inclined to be presented in the scintigraphic abnormalities such as the increased uptake of radioisotope in the spleen and bone marrow than the deteriorations in biochemical liver function tests. Moreover, the increased radioisotope uptake by spleen and bone marrow in hepatic scintigram highly correlated with histological deteriorations. On the other hand, in the cases with histological improvement no scintigraphic improvement was ovserved. 2. Comparing the changes in the result of liver function tests with histological features, biochemical deteriorations significantly correlated with histological deteriorations, although biochemical improvements were not reliable indicators of histological improvements. 3. Changes in biochemical parameters such as serum GOT, GPT, albumin, γ-globulin, TTT and ALP were analyzed by means of Hayashi's second method of quantification and predictive values for histological feactures were calculated. As a result, histological deteriorations were predicted in 89.5% of the cases, but histological improvements were predicted only in 66.7%. In the various biochemical parameters, γ-globulin was considered as most important in predicting histological features and ALP was ranked the second. (J.P.N.)

  13. Human tumour xenografts established and serially transplanted in mice immunologically deprived by thymectomy, cytosine arabinoside and whole-body irradiation

    International Nuclear Information System (INIS)

    Selby, P.J.; Thomas, J.M.; Peckham, M.J.

    1980-01-01

    Mice immunologically deprived by thymectomy, cytosine arabinoside treatment and whole-body irradiation were used to study the growth of human tumours as xenografts. 10/16 melanoma biopsies, 4/13 ovarian carcinoma biopsies and 3/6 uterine cancer biopsies grew as serially transplantable xenograft lines. The tumour lines were studied through serial passages by histology, histo-chemistry, electron microscopy, chromosome analysis, immune fluorescence, growth rate measurement and mitotic counts. They retained the characteristics of the tumours of origin, with the exception of loss of pigmentation in two melanomas, histological dedifferentiation in the uterine carcinomas, and increased mitotic frequency and growth rate in some melanomas. It was concluded that this type of animal preparation is as useful as alternative methods of immunological deprivation, or as athymic nude mice, for the growth of human tumour xenografts, at least for some experimental purposes. (author)

  14. High-sensitivity cardiac troponin I assay to screen for acute rejection in patients with heart transplant.

    Science.gov (United States)

    Patel, Parag C; Hill, Douglas A; Ayers, Colby R; Lavingia, Bhavna; Kaiser, Patricia; Dyer, Adrian K; Barnes, Aliessa P; Thibodeau, Jennifer T; Mishkin, Joseph D; Mammen, Pradeep P A; Markham, David W; Stastny, Peter; Ring, W Steves; de Lemos, James A; Drazner, Mark H

    2014-05-01

    A noninvasive biomarker that could accurately diagnose acute rejection (AR) in heart transplant recipients could obviate the need for surveillance endomyocardial biopsies. We assessed the performance metrics of a novel high-sensitivity cardiac troponin I (cTnI) assay for this purpose. Stored serum samples were retrospectively matched to endomyocardial biopsies in 98 cardiac transplant recipients, who survived ≥3 months after transplant. AR was defined as International Society for Heart and Lung Transplantation grade 2R or higher cellular rejection, acellular rejection, or allograft dysfunction of uncertain pathogenesis, leading to treatment for presumed rejection. cTnI was measured with a high-sensitivity assay (Abbott Diagnostics, Abbott Park, IL). Cross-sectional analyses determined the association of cTnI concentrations with rejection and International Society for Heart and Lung Transplantation grade and the performance metrics of cTnI for the detection of AR. Among 98 subjects, 37% had ≥1 rejection episode. cTnI was measured in 418 serum samples, including 35 paired to a rejection episode. cTnI concentrations were significantly higher in rejection versus nonrejection samples (median, 57.1 versus 10.2 ng/L; P<0.0001) and increased in a graded manner with higher biopsy scores (P(trend)<0.0001). The c-statistic to discriminate AR was 0.82 (95% confidence interval, 0.76-0.88). Using a cut point of 15 ng/L, sensitivity was 94%, specificity 60%, positive predictive value 18%, and negative predictive value 99%. A high-sensitivity cTnI assay seems useful to rule out AR in cardiac transplant recipients. If validated in prospective studies, a strategy of serial monitoring with a high-sensitivity cTnI assay may offer a low-cost noninvasive strategy for rejection surveillance. © 2014 American Heart Association, Inc.

  15. Serially cultured keratinocytes from human scalp hair follicles: a tool for cytogenetic studies.

    Science.gov (United States)

    Weterings, P J; Roelofs, H M; Jansen, B A; Vermorken, A J

    1983-01-01

    Keratinocytes originating from adult human hair follicles, the most convenient biopsy tissue, can be serially cultured using a combination of two techniques. Primary cultures are established using plucked scalp hair follicles and the bovine eye lens capsule as a growth substrate. Subsequently, cells from these cultures are serially cultivated in the presence of irradiated 3T3 cells as feeders. By this combination of techniques many keratinocytes can be generated from one single hair follicle. These cultures, appropriately treated with colchicine, can provide an adequate number of metaphases suitable for chromosome studies.

  16. Improvement of myocardial perfusion reserve detected by cardiovascular magnetic resonance after direct endomyocardial implantation of autologous bone marrow cells in patients with severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Lau Chu-Pak

    2010-01-01

    Full Text Available Abstract Background Recent studies suggested that bone marrow (BM cell implantation in patients with severe chronic coronary artery disease (CAD resulted in modest improvement in symptoms and cardiac function. This study sought to investigate the functional changes that occur within the chronic human ischaemic myocardium after direct endomyocardial BM cells implantation by cardiovascular magnetic resonance (CMR. Methods and Results We compared the interval changes of left ventricular ejection fraction (LVEF, myocardial perfusion reserve and the extent of myocardial scar by using late gadolinium enhancement CMR in 12 patients with severe CAD. CMR was performed at baseline and at 6 months after catheter-based direct endomyocardial autologous BM cell (n = 12 injection to viable ischaemic myocardium as guided by electromechanical mapping. In patients randomized to receive BM cell injection, there was significant decrease in percentage area of peri-infarct regions (-23.6%, P = 0.04 and increase in global LVEF (+9.0%, P = 0.02, the percentage of regional wall thickening (+13.1%, P= 0.04 and MPR (+0.25%, P = 0.03 over the target area at 6-months compared with baseline. Conclusions Direct endomyocardial implantation of autologous BM cells significantly improved global LVEF, regional wall thickening and myocardial perfusion reserve, and reduced percentage area of peri-infarct regions in patients with severe CAD.

  17. Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2008-01-01

    Full Text Available Abstract Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures.

  18. Antimyosin imaging in cardiac transplant rejection

    International Nuclear Information System (INIS)

    Johnson, L.L.; Cannon, P.J.

    1991-01-01

    Fab fragments of antibodies specific for cardiac myosin have been labeled with indium-111 and injected intravenously into animals and into patients with heart transplants. The antibodies, developed by Khaw, Haber, and co-workers, localize in cardiac myocytes that have been damaged irreversibly by ischemia, myocarditis, or the rejection process. After clearance of the labeled antibody from the cardiac blood pool, planar imaging or single photon emission computed tomography is performed. Scintigrams reveal the uptake of the labeled antimyosin in areas of myocardium undergoing transplant rejection. In animal studies, the degree of antimyosin uptake appears to correlate significantly with the degree of rejection assessed at necropsy. In patients, the correlation between scans and pathologic findings from endomyocardial biopsy is not as good, possibly because of sampling error in the endomyocardial biopsy technique. The scan results at 1 year correlate with either late complications (positive) or benign course (negative). Current limitations of the method include slow blood clearance, long half-life of indium-111, and hepatic uptake. Overcoming these limitations represents a direction for current research. It is possible that from these efforts a noninvasive approach to the diagnosis and evaluation of cardiac transplantation may evolve that will decrease the number of endomyocardial biopsies required to evaluate rejection. This would be particularly useful in infants and children. 31 references

  19. Repeated measurements of NT-pro-B-type natriuretic peptide, troponin T or C-reactive protein do not predict future allograft rejection in heart transplant recipients.

    Science.gov (United States)

    Battes, Linda C; Caliskan, Kadir; Rizopoulos, Dimitris; Constantinescu, Alina A; Robertus, Jan L; Akkerhuis, Martijn; Manintveld, Olivier C; Boersma, Eric; Kardys, Isabella

    2015-03-01

    Studies on the prognostic value of serial biomarker assays for future occurrence of allograft rejection (AR) are scarce. We examined whether repeated measurements of NT-pro-B-type natriuretic peptide (NT-proBNP), troponin T (TropT) and C-reactive protein (CRP) predict AR. From 2005 to 2010, 77 consecutive heart transplantation (HTx) recipients were included. The NT-proBNP, TropT, and CRP were measured at 16 ± 4 (mean ± standard deviation) consecutive routine endomyocardial biopsy surveillance visits during the first year of follow-up. Allograft rejection was defined as International Society for Heart and Lung Transplantation (ISHLT) grade 2R or higher at endomyocardial biopsy. Joint modeling was used to assess the association between repeated biomarker measurements and occurrence of future AR. Joint modeling accounts for dependence among repeated observations in individual patients. The mean age of the patients at HTx was 49 ± 9.2 years, and 68% were men. During the first year of follow-up, 1,136 biopsies and concurrent blood samples were obtained, and 56 patients (73%) experienced at least one episode of AR. All biomarkers were elevated directly after HTx and achieved steady-state after ∼ 12 weeks, both in patients with or without AR. No associations were present between the repeated measurements of NT-proBNP, TropT, or CRP and AR both early (weeks 0-12) and late (weeks 13-52) in the course after HTx (hazard ratios for weeks 13-52: 0.96 (95% confidence interval, 0.55-1.68), 0.67 (0.27-1.69), and 1.44 (0.90-2.30), respectively, per ln[unit]). Combining the three biomarkers in one model also rendered null results. The temporal evolution of NT-proBNP, TropT, and CRP before AR did not predict occurrence of acute AR both in the early and late course of the first year after HTx.

  20. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  1. cDNA Microarray Analysis of Serially Sampled Cervical Cancer Specimens From Patients Treated With Thermochemoradiotherapy

    International Nuclear Information System (INIS)

    Borkamo, Erling Dahl; Schem, Baard-Christian; Fluge, Oystein; Bruland, Ove; Dahl, Olav; Mella, Olav

    2009-01-01

    Purpose: To elucidate changes in gene expression after treatment with regional thermochemoradiotherapy in locally advanced squamous cell cervical cancer. Methods and Materials: Tru-Cut biopsy specimens were serially collected from 16 patients. Microarray gene expression levels before and 24 h after the first and second trimodality treatment sessions were compared. Pathway and network analyses were conducted by use of Ingenuity Pathways Analysis (IPA; Ingenuity Systems, Redwood City, CA). Single gene expressions were analyzed by quantitative real-time reverse transcription-polymerase chain reaction. Results: We detected 53 annotated genes that were differentially expressed after trimodality treatment. Central in the three top networks detected by IPA were interferon alfa, interferon beta, and interferon gamma receptor; nuclear factor κB; and tumor necrosis factor, respectively. These genes encode proteins that are important in regulation cell signaling, proliferation, gene expression, and immune stimulation. Biological processes over-represented among the 53 genes were fibrosis, tumorigenesis, and immune response. Conclusions: Microarrays showed minor changes in gene expression after thermochemoradiotherapy in locally advanced cervical cancer. We detected 53 differentially expressed genes, mainly involved in fibrosis, tumorigenesis, and immune response. A limitation with the use of serial biopsy specimens was low quality of ribonucleic acid from tumors that respond to highly effective therapy. Another 'key limitation' is timing of the post-treatment biopsy, because 24 h may be too late to adequately assess the impact of hyperthermia on gene expression.

  2. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  3. Recommendations for processing cardiovascular surgical pathology specimens: a consensus statement from the Standards and Definitions Committee of the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology

    NARCIS (Netherlands)

    Stone, James R.; Basso, Cristina; Baandrup, Ulrik T.; Bruneval, Patrick; Butany, Jagdish; Gallagher, Patrick J.; Halushka, Marc K.; Miller, Dylan V.; Padera, Robert F.; Radio, Stanley J.; Sheppard, Mary N.; Suvarna, Kim; Tan, Carmela D.; Thiene, Gaetano; van der Wal, Allard C.; Veinot, John P.

    2012-01-01

    With the advent of molecular subclassification of diseases, much consideration should be given to the proper processing of cardiovascular surgical pathology specimens to maximize patient care. Such specimens include endomyocardial biopsies, cardiac myectomy specimens, cardiac apical core segments,

  4. Serial killers with military experience: applying learning theory to serial murder.

    Science.gov (United States)

    Castle, Tammy; Hensley, Christopher

    2002-08-01

    Scholars have endeavored to study the motivation and causality behind serial murder by researching biological, psychological, and sociological variables. Some of these studies have provided support for the relationship between these variables and serial murder. However, the study of serial murder continues to be an exploratory rather than explanatory research topic. This article examines the possible link between serial killers and military service. Citing previous research using social learning theory for the study of murder, this article explores how potential serial killers learn to reinforce violence, aggression, and murder in military boot camps. As with other variables considered in serial killer research, military experience alone cannot account for all cases of serial murder. Future research should continue to examine this possible link.

  5. Adult-onset nemaline myopathy in a dog presenting with persistent atrial standstill and primary hypothyroidism.

    Science.gov (United States)

    Nakamura, R K; Russell, N J; Shelton, G D

    2012-06-01

    A nine-year-old neutered female mixed breed dog presented for evaluation following a five-day history of lethargy, inappetence, weakness, abdominal distension and generalised muscle atrophy. Persistent vatrial standstill with a junctional rhythm was identified on electrocardiogram. Echocardiogram identified moderate dilation of all cardiac chambers and mild thickening of the mitral and tricuspid valves. Serology was negative for Neospora caninum and Toxoplasma gondii. Permanent pacemaker implantation was performed in addition to endomyocardial and skeletal muscle biopsies. Cryosections from the biceps femoris muscle showed numerous nemaline rod bodies while endomyocardial biopsies were possibly consistent with end-stage myocarditis. Rod bodies have rarely been reported in the veterinary literature. To the authors' knowledge, this is the first report of adult-onset nemaline rod myopathy and hypothyroidism with concurrent cardiac disease in a dog. © 2012 British Small Animal Veterinary Association.

  6. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  7. Acute left ventricular failure in a patient with hydroxychloroquine-induced cardiomyopathy

    NARCIS (Netherlands)

    Hartmann, M.; Hartmann, M.; Meek, I.L.; van Houwelingen, G.K.; Lambregts, H.P.C.M.; Toes, G.J.; van der Wal, A.C.; von Birgelen, Clemens

    2011-01-01

    We present the case of a 75-year-old woman with a medical history of rheumatoid arthritis treated with hydroxychloroquine, who was admitted with acute left-sided heart failure due to a hydroxychloroquine-induced cardiomyopathy as supported by endomyocardial biopsy

  8. Alloreactive lymphoid infiltrates in human heart transplants: Loss of class II-directed cytotoxicity more than 3 months after transplantation

    NARCIS (Netherlands)

    A.J. Ouwehand; L.M.B. Vaessen (Leonard); C.C. Baan (Carla); N.H.P.M. Jutte (Nicolet); A.H.M.M. Balk (Aggie); C.E. Essed; E. Bos (Egbert); F.H.J. Claas (Frans); W. Weimar (Willem)

    1991-01-01

    markdownabstractAbstract From 535 endomyocardial biopsies (87 heart transplant recipients) 283 cell cultures could be generated. All cultures tested contained T lymphocytes and in most cases CD4 was the predominant phenotype at any time posttransplant. A significantly higher proportion of

  9. Posttreatment biopsy results following interstitial brachytherapy in early-stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Hoak, David C.; Grimm, Peter D.; Ragde, Haakon; Cavanagh, William; Blasko, John C.

    1997-01-01

    Purpose: To assess pathologic control rates for prostatic carcinoma as determined by postimplant prostate biopsy in a large series of consecutive patients who have received permanent interstitial brachytherapy using a contemporary transrectal ultrasound-directed, transperineal, computer generated, volume technique. Methods and Materials: Four hundred and two patients received permanent 125 I or 103 Pd interstitial brachytherapy as primary treatment for early stage prostatic carcinoma at the Northwest Tumor Institute between January 1988 and January 1994. Of these, 201 have consented to biopsy 12 or more months postimplant with a median follow-up of 40 months (range: 12-83 months). None had received homonal manipulation. A total of 361 biopsies was performed on 201 patients with a range of one to six annual biopsies per patient (91 received multiple, serial biopsies). Of the 161 patients more than 12 months postimplant who have not been biopsied, most have been unwilling or unable to submit to biopsy. Only six patients with biochemical progression have not been biopsied. There was no difference in the presenting characteristics or implant parameters between those patients biopsied and those that were not. One hundred and forty-three received 125 I (71%) prescribed to a MPD of 160 Gy with a median activity of 35.5 mCi, and 58 (29%) received 103 Pd prescribed to a MPD of 115 Gy with a median activity of 123 mCi. Multiple biopsies were performed under transrectal ultrasound guidance, and all specimens were classified as either negative, indeterminate, or positive. Results: At the time of last biopsy, 161 (80%) have achieved negative pathology, 34 (17%) remain indeterminate, and 6 (3%) have been positive. Only 2 of the 186 patients with a PSA < 4.0 ng/ml at the time of biopsy were positive. Among those 33 indeterminate patients with a subsequent biopsy, 28 have converted to negative, 2 to positive, and 3 remain unchanged to date. Conclusions: These data demonstrate at

  10. Clinical and pathologic findings of myocarditis in two families with dilated cardiomyopathy

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Fowles, R.E.; Robinson, J.A.; Subramanian, R.; Henkin, R.E.; Gunnar, R.M.

    1984-01-01

    The use of endomyocardial biopsy and gallium-67 scans in patients with dilated cardiomyopathy (DCM) has demonstrated the presence of myocardial inflammation in a subset of patients. A family with DCM was studied with endomyocardial biopsy and gallium-67 scanning; both identified the presence of myocarditis in the proband. Evaluation of histologic sections from deceased family members revealed myocarditis as the principal pathologic finding. This patient identified during life demonstrated a defect in suppressor lymphocytic function and improved with immunosuppressive therapy. A second family with DCM was discovered when postmortem examination of the proband and his father's heart showed myocarditis. A living sibling was identified with asymptomatic myocardial dysfunction. Longitudinal follow-up of surviving members of both families are in progress. This study indicates that thorough diagnostic evaluation of all patients with familial DCM should be pursued to identify subgroups with potentially treatable inflammation

  11. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  12. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  13. Breast Cancer Arising Adjacent to an Involuting Fibroadenoma: Serial Changes in Radiologic Features

    Science.gov (United States)

    Park, Chae Jung; Kim, Eun-Kyung; Woo, Ha Young; Moon, Hee Jung; Yoon, Jung Hyun

    2015-01-01

    Fibroadenoma is a common benign breast lesion and its malignant transformation is rare. There have been several case reports and studies that retrospectively reviewed breast cancers that arose within fibroadenomas; however, none of these studies reported serial changes in radiologic features of the cancer, including findings from mammography and ultrasound (US). We report a case of breast cancer arising adjacent to an involuting fibro adenoma in a 39-year-old woman who was undergoing serial follow-up after her fibroadenoma was diagnosed. Seven years after her diagnosis, the lesion showed evidence of coarse calcifications, a typical sign of involution. Four years later, US revealed a newly developed hypoechoic lesion with irregular margins and peripherally located calcifications adjacent to the fibroadenoma. A core biopsy was performed, and histopathological examination resulted in a diagnosis of invasive ductal carcinoma. When new suspicious features are observed in a fibroadenoma, radiologists should raise the concern for breast cancer and proceed with diagnosis and treatment accordingly. PMID:26472981

  14. Decreasing Serial Cost Sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Østerdal, Lars Peter

    The increasing serial cost sharing rule of Moulin and Shenker [Econometrica 60 (1992) 1009] and the decreasing serial rule of de Frutos [Journal of Economic Theory 79 (1998) 245] have attracted attention due to their intuitive appeal and striking incentive properties. An axiomatic characterization...... of the increasing serial rule was provided by Moulin and Shenker [Journal of Economic Theory 64 (1994) 178]. This paper gives an axiomatic characterization of the decreasing serial rule...

  15. Decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Østerdal, Lars Peter Raahave

    2009-01-01

    The increasing serial cost sharing rule of Moulin and Shenker (Econometrica 60:1009-1037, 1992) and the decreasing serial rule of de Frutos (J Econ Theory 79:245-275, 1998) are known by their intuitive appeal and striking incentive properties. An axiomatic characterization of the increasing serial...... rule was provided by Moulin and Shenker (J Econ Theory 64:178-201, 1994). This paper gives an axiomatic characterization of the decreasing serial rule....

  16. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  17. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  18. Importance of liver biopsy findings in immunosuppression management: biopsy monitoring and working criteria for patients with operational tolerance.

    Science.gov (United States)

    2012-10-01

    Obstacles to morbidity-free long-term survival after liver transplantation (LT) include complications of immunosuppression (IS), recurrence of the original disease and malignancies, and unexplained chronic hepatitis and graft fibrosis. Many programs attempt to minimize chronic exposure to IS by reducing dosages and stopping steroids. A few programs have successfully weaned a highly select group of recipients from all IS without apparent adverse consequences, but long-term follow-up is limited. Patients subjected to adjustments in IS are usually followed by serial liver chemistry tests, which are relatively insensitive methods for detecting allograft damage. Protocol biopsy has largely been abandoned for hepatitis C virus-negative recipients, at least in part because of the inability to integrate routine histopathological findings into a rational clinical management algorithm. Recognizing a need to more precisely categorize and determine the clinical significance of findings in long-term biopsy samples, the Banff Working Group on Liver Allograft Pathology has reviewed the literature, pooled the experience of its members, and proposed working definitions for biopsy changes that (1) are conducive to lowering IS and are compatible with operational tolerance (OT) and (2) raise concern for closer follow-up and perhaps increased IS during or after IS weaning. The establishment of guidelines should help us to standardize analyses of the effects of various treatments and/or weaning protocols and more rigorously categorize patients who are assumed to show OT. Long-term follow-up using standardized criteria will help us to determine the consequences of lowering IS and to define and determine the incidence and robustness of OT in liver allografts. Copyright © 2012 American Association for the Study of Liver Diseases.

  19. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  20. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  1. Live birth following serial vitrification of embryos and PGD for fragile X syndrome in a patient with the premutation and decreased ovarian reserve.

    Science.gov (United States)

    Nayot, Dan; Chung, Jin Tae; Son, Weon-Young; Ao, Assangla; Hughes, Mark; Dahan, Michael H

    2013-11-01

    To present a live birth resulting from serial vitrification of embryos and pre-implantation genetic diagnosis (PGD). A 31-year-old with primary infertility, fragile-X premutation, and decreased ovarian reserve (DOR) (baseline FSH level 33 IU/L), presented after failing to stimulate to follicle diameters >10 mm with three cycles of invitro fertilization (IVF). After counseling, the couple opted for serial in-vitro maturation (IVM), embryo vitrification, and genetic testing using array comparative genomic hybridization (aCGH) and PGD. Embryos were vitrified 2 days after intra-cytoplasmic sperm injection (ICSI). Thawed embryos were biopsied on day-three and transferred on day-five. The couple underwent 20 cycles of assisted reproductive technology. A total of 23 in-vivo mature and five immature oocytes were retrieved, of which one matured in-vitro. Of 24 embryos, 17/24 (71 %) developed to day two and 11/24 (46 %) survived to blastocyst stage with a biopsy result available. Four blastocysts had normal PGD and aCGH results. Both single embryo transfers resulted in a successful implantation, one a blighted ovum and the other in a live birth. Young patients with DOR have potential for live birth as long as oocytes can be obtained and embryos created. Serial vitrification may be the mechanism of choice in these patients when PGD is needed.

  2. SERIAL PERCENT-FREE PSA IN COMBINATION WITH PSA FOR POPULATION-BASED EARLY DETECTION OF PROSTATE CANCER

    Science.gov (United States)

    Ankerst, Donna Pauler; Gelfond, Jonathan; Goros, Martin; Herrera, Jesus; Strobl, Andreas; Thompson, Ian M.; Hernandez, Javier; Leach, Robin J.

    2016-01-01

    PURPOSE To characterize the diagnostic properties of serial percent-free prostate-specific antigen (PSA) in relation to PSA in a multi-ethnic, multi-racial cohort of healthy men. MATERIALS AND METHODS 6,982 percent-free PSA and PSA measures were obtained from participants in a 12 year+ Texas screening study comprising 1625 men who never underwent biopsy, 497 who underwent one or more biopsies negative for prostate cancer, and 61 diagnosed with prostate cancer. Area underneath the receiver-operating-characteristic-curve (AUC) for percent-free PSA, and the proportion of patients with fluctuating values across multiple visits were determined according to two thresholds (under 15% versus 25%) were evaluated. The proportion of cancer cases where percent-free PSA indicated a positive test before PSA > 4 ng/mL did and the number of negative biopsies that would have been spared by percent-free PSA testing negative were computed. RESULTS Percent-free PSA fluctuated around its threshold of PSA tested positive earlier than PSA in 71.4% (34.2%) of cancer cases, and among men with multiple negative biopsies and a PSA > 4 ng/mL, percent-free PSA would have tested negative in 31.6% (65.8%) instances. CONCLUSIONS Percent-free PSA should accompany PSA testing in order to potentially spare unnecessary biopsies or detect cancer earlier. When near the threshold, both tests should be repeated due to commonly observed fluctuation. PMID:26979652

  3. Complete removal of a breast mass by US-guided mammotome biopsy: histologic assessment by marginal sampling

    International Nuclear Information System (INIS)

    Kim, Youn Jeong; Choi, Hye Young; Moon, Byung In; Lee, Shi Nae

    2005-01-01

    The aim of this study was to assess whether the complete removal of a breast mass using ultrasound (US) guided mammotome biopsy was successful using a marginal biopsy after insuring the total visual excision of the breast mass on US images. The relationship of complete breast mass removal, and the hematoma, mass size and shape were also evaluated. A US guided mammotome biopsy was performed in a total of 136 cases in 133 patients, with marginal biopsies also added when the complete removal of breast mass had been identified by sonography. The results of the marginal biopsies were serially dividing into three groups, as follows: group I were the cases in the initial 6 months, group II after the initial 6 months and group III having undergone two marginal biopsies. The marginal biopsies were performed in four directions around the probe, with 'marginal positivity' defined as the same histopathological findings to that of the main mass in at least one direction. A statistical analysis was also used to evaluate between the marginal positivity and the hematoma, mass size and shape. The marginal positivities of groups I, II and III were 48.8, 29.4 and 45.5%, respectively. The marginal positivity of those with a lobular shaped mass was significantly higher (ρ = 0.0121) than those with round or oval shaped masses (61.5 vs 33.7 vs 50%), but showed no statistical relationship with hematoma size of the lesions. Although the lesions were removed by US using a US-guided mammotome biopsy, many residual lesions were still histologically present in the marginal samplings, especially in the lobular shaped masse

  4. Improvised double-embedding technique of minute biopsies: a mega boon to histopathology laboratory.

    Science.gov (United States)

    Yadav, Lokendra; Thomas, Sarega; Kini, Usha

    2015-01-01

    Optimal orientation of minute mucosal biopsies is essential for a definite diagnosis in gastrointestinal pathology or to visualize neural plexuses in Hirschsprung disease. The problem of minute size of the biopsy and its orientation gets compounded when they are from neonates and mandates exhaustive strip cuts, thus delaying reporting. A modified agar-paraffin technique is aimed to make tissue embedding efficient and user-friendly by inking mapping biopsies (one or more) either fresh or fixed with surgical coloring inks followed by embedding first in agar after orientation and followed thereafter by processing, re-embedding in paraffin wax, sectioning and staining. The tissues in agar paraffin block were found to be well processed, firm, held secure and well preserved. The blocks were easy to cut, with serial sections of thickness 2-3 μ and easy to spread. The colored inks remained permanently on the tissues both in the block as well as on the sections which helped in easy identification of tissues. Agar did not interfere with any stain such as Hematoxylin and Eosin or with histochemical stains, enzyme histochemistry or immunohistochemistry. Inking biopsies and pooling them in a block when obtained from the same patient reduced the number of tissue blocks. The modified agar-paraffin embedding technique is a simple reliable user friendly method that can greatly improve the quality of diagnostic information from minute biopsies by optimal orientation, better quality of sections, faster turnaround time and cost-effectiveness by economizing on the number of paraffin blocks, manpower, chemical reagents and laboratory infrastructure.

  5. Improvised double-embedding technique of minute biopsies: A mega boon to histopathology laboratory

    Directory of Open Access Journals (Sweden)

    Lokendra Yadav

    2015-01-01

    Full Text Available Introduction: Optimal orientation of minute mucosal biopsies is essential for a definite diagnosis in gastrointestinal pathology or to visualize neural plexuses in Hirschsprung disease. The problem of minute size of the biopsy and its orientation gets compounded when they are from neonates and mandates exhaustive strip cuts, thus delaying reporting. Aim: A modified agar-paraffin technique is aimed to make tissue embedding efficient and user-friendly by inking mapping biopsies (one or more either fresh or fixed with surgical coloring inks followed by embedding first in agar after orientation and followed thereafter by processing, re-embedding in paraffin wax, sectioning and staining. Results: The tissues in agar paraffin block were found to be well processed, firm, held secure and well preserved. The blocks were easy to cut, with serial sections of thickness 2-3 μ and easy to spread. The colored inks remained permanently on the tissues both in the block as well as on the sections which helped in easy identification of tissues. Agar did not interfere with any stain such as Hematoxylin and Eosin or with histochemical stains, enzyme histochemistry or immunohistochemistry. Inking biopsies and pooling them in a block when obtained from the same patient reduced the number of tissue blocks. Conclusion: The modified agar-paraffin embedding technique is a simple reliable user friendly method that can greatly improve the quality of diagnostic information from minute biopsies by optimal orientation, better quality of sections, faster turnaround time and cost-effectiveness by economizing on the number of paraffin blocks, manpower, chemical reagents and laboratory infrastructure.

  6. Serial position markers in space: visuospatial priming of serial order working memory retrieval.

    Directory of Open Access Journals (Sweden)

    Maya De Belder

    Full Text Available Most general theories on serial order working memory (WM assume the existence of position markers that are bound to the to-be-remembered items to keep track of the serial order. So far, the exact cognitive/neural characteristics of these markers have remained largely underspecified, while direct empirical evidence for their existence is mostly lacking. In the current study we demonstrate that retrieval from verbal serial order WM can be facilitated or hindered by spatial cuing: begin elements of a verbal WM sequence are retrieved faster after cuing the left side of space, while end elements are retrieved faster after cuing the right side of space. In direct complement to our previous work--where we showed the reversed impact of WM retrieval on spatial processing--we argue that the current findings provide us with a crucial piece of evidence suggesting a direct and functional involvement of space in verbal serial order WM. We outline the idea that serial order in verbal WM is coded within a spatial coordinate system with spatial attention being involved when searching through WM, and we discuss how this account can explain several hallmark observations related to serial order WM.

  7. CD16+ Monocytes and Skewed Macrophage Polarization toward M2 Type Hallmark Heart Transplant Acute Cellular Rejection

    OpenAIRE

    van den Bosch, Thierry P. P.; Caliskan, Kadir; Kraaij, Marina D.; Constantinescu, Alina A.; Manintveld, Olivier C.; Leenen, Pieter J. M.; von der Th?sen, Jan H.; Clahsen-van Groningen, Marian C.; Baan, Carla C.; Rowshani, Ajda T.

    2017-01-01

    textabstractBackground: During acute heart transplant rejection, infiltration of lymphocytes and monocytes is followed by endothelial injury and eventually myocardial fibrosis. To date, no information is available on monocyte-macrophage-related cellular shifts and their polarization status during rejection. Here, we aimed to define and correlate monocyte-macrophage endomyocardial tissue profiles obtained at rejection and time points prior to rejection, with corresponding serial blood samples ...

  8. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  9. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  10. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  11. Serial Expression Analysis: a web tool for the analysis of serial gene expression data

    Science.gov (United States)

    Nueda, Maria José; Carbonell, José; Medina, Ignacio; Dopazo, Joaquín; Conesa, Ana

    2010-01-01

    Serial transcriptomics experiments investigate the dynamics of gene expression changes associated with a quantitative variable such as time or dosage. The statistical analysis of these data implies the study of global and gene-specific expression trends, the identification of significant serial changes, the comparison of expression profiles and the assessment of transcriptional changes in terms of cellular processes. We have created the SEA (Serial Expression Analysis) suite to provide a complete web-based resource for the analysis of serial transcriptomics data. SEA offers five different algorithms based on univariate, multivariate and functional profiling strategies framed within a user-friendly interface and a project-oriented architecture to facilitate the analysis of serial gene expression data sets from different perspectives. SEA is available at sea.bioinfo.cipf.es. PMID:20525784

  12. Circulating cell-free DNA and circulating tumor cells, the "liquid biopsies" in ovarian cancer.

    Science.gov (United States)

    Cheng, Xianliang; Zhang, Lei; Chen, Yajuan; Qing, Chen

    2017-11-13

    Limited understanding of ovarian cancer (OC) genome portrait has hindered the therapeutic advances. The serial monitoring of tumor genotypes is becoming increasingly attainable with circulating cell-free DNA (cf-DNA) and circulating tumor cells (CTCs) emerging as "liquid biopsies". They represent non-invasive biomarkers and are viable, as they can be isolated from human plasma, serum and other body fluids. Molecular characterization of circulating tumor DNA (ct-DNA) and CTCs offer unique potentials to better understand the biology of metastasis and resistance to therapies. The liquid biopsies may also give innovative insights into the process of rapid and accurate identification, resistant genetic alterations and a real time monitoring of treatment responses. In addition, liquid biopsies are shedding light on elucidating signal pathways involved in invasiveness and metastasis competence; but the detection and molecular characterization of ct-DNA and CTCs are still challenging, since they are rare, and the amount of available samples are very limited. This review will focus on the clinical potential of ct-DNA and CTCs in both the early and advanced diagnosis, prognosis, and in the identification of resistance mutations in OC.

  13. Developments in Serials: 1977

    Science.gov (United States)

    James, John R.

    1978-01-01

    Discusses issues and developments relating to several aspects of serials, including economics and acquisitions; bibliographic control; automation; education; serials literature and bibliographies; and copyrights. A bibliography is included. (Author/MBR)

  14. Malaysian Serials: Issues and Problems.

    Science.gov (United States)

    Bahri, Che Norma

    This paper analyzes the issues and problems while looking at the trends and developments of serials publishing in Malaysia. The first section provides background; topics addressed include the country and people of Malaysia, the history of serials publishing in Malaysia, categories and formats of serials publishing, academic publications,…

  15. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  16. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  17. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  18. CRNL library serials list

    International Nuclear Information System (INIS)

    Alburger, T.P.

    1982-04-01

    A list of 1900 serial publications (periodicals, society transactions and proceedings, annuals and directories, indexes, newspapers, etc.) is presented with volumes and years held by the Main Library. This library is the largest in AECL as well as one of the largest scientific and technical libraries in North America, and functions as a Canadian resource for nuclear information. A main alphabetical list is followed by broad subject field lists representing research interests, and lists of abstract and index serials, general bibliographic serials, conference indexes, press releases, English translations, and original language journals

  19. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  20. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  1. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  2. The Application of Digital Pathology to Improve Accuracy in Glomerular Enumeration in Renal Biopsies.

    Directory of Open Access Journals (Sweden)

    Avi Z Rosenberg

    Full Text Available In renal biopsy reporting, quantitative measurements, such as glomerular number and percentage of globally sclerotic glomeruli, is central to diagnostic accuracy and prognosis. The aim of this study is to determine the number of glomeruli and percent globally sclerotic in renal biopsies by means of registration of serial tissue sections and manual enumeration, compared to the numbers in pathology reports from routine light microscopic assessment.We reviewed 277 biopsies from the Nephrotic Syndrome Study Network (NEPTUNE digital pathology repository, enumerating 9,379 glomeruli by means of whole slide imaging. Glomerular number and the percentage of globally sclerotic glomeruli are values routinely recorded in the official renal biopsy pathology report from the 25 participating centers. Two general trends in reporting were noted: total number per biopsy or average number per level/section. Both of these approaches were assessed for their accuracy in comparison to the analogous numbers of annotated glomeruli on WSI.The number of glomeruli annotated was consistently higher than those reported (p<0.001; this difference was proportional to the number of glomeruli. In contrast, percent globally sclerotic were similar when calculated on total glomeruli, but greater in FSGS when calculated on average number of glomeruli (p<0.01. The difference in percent globally sclerotic between annotated and those recorded in pathology reports was significant when global sclerosis is greater than 40%.Although glass slides were not available for direct comparison to whole slide image annotation, this study indicates that routine manual light microscopy assessment of number of glomeruli is inaccurate, and the magnitude of this error is proportional to the total number of glomeruli.

  3. Scientific and Technical Serials Holdings Optimization in an Inefficient Market: A LSU Serials Redesign Project Exercise.

    Science.gov (United States)

    Bensman, Stephen J.; Wilder, Stanley J.

    1998-01-01

    Analyzes the structure of the library market for scientific and technical (ST) serials. Describes an exercise aimed at a theoretical reconstruction of the ST-serials holdings of Louisiana State University (LSU) Libraries. Discusses the set definitions, measures, and algorithms necessary in the design of a computer program to appraise ST serials.…

  4. Union Listing via OCLC's Serials Control Subsystem.

    Science.gov (United States)

    O'Malley, Terrence J.

    1984-01-01

    Describes library use of Conversion of Serials Project's (CONSER) online national machine-readable database for serials to create online union lists of serials via OCLC's Serial Control Subsystem. Problems in selection of appropriate, accurate, and authenticated records and prospects for the future are discussed. Twenty sources and sample records…

  5. Neopterin and Beta-2 Microglobulin Relations to Immunity and Inflammatory Status in Nonischemic Dilated Cardiomyopathy Patients

    Directory of Open Access Journals (Sweden)

    Celina Wojciechowska

    2014-01-01

    Full Text Available Background. The aim of the study was to assess the relationships among serum neopterin (NPT, β2-microglobulin (β2-M levels, clinical status, and endomyocardial biopsy results of dilated cardiomyopathy patients (DCM. Methods. Serum NPT and β-2 M were determined in 172 nonischaemic DCM patients who underwent right ventricular endomyocardial biopsy and 30 healthy subjects (ELISA test. The cryostat biopsy specimens were assessed using histology, immunohistology, and immunochemistry methods (HLA ABC, HLA DR expression, CD3 + lymphocytes, and macrophages counts. Results. The strong increase of HLA ABC or HLA DR expression was detected in 27.2% patients—group A—being low in 72.8% patients—group B. Neopterin level was increased in patients in group A compared to healthy controls 8.11 (4.50–12.57 versus 4.99 (2.66–8.28 nmol/L (P<0.05. β-2 microglobulin level was higher in DCM groups A (2.60 (1.71–3.58 and B (2.52 (1.51–3.72 than in the control group 1.75 (1.28–1.96 mg/L, P<0.001. Neopterin correlated positively with the number of macrophages in biopsy specimens (P<0.05 acute phase proteins: C-reactive proteins (P<0.05; fibrinogen (P<0.01; and NYHA functional class (P<0.05 and negatively with left ventricular ejection fraction (P<0.05. Conclusions. Neopterin but not β-2 microglobulin concentration reflected immune response in biopsy specimens. Neopterin correlated with acute phase proteins and stage of heart failure and may indicate a general immune and inflammatory activation in heart failure.

  6. Serial Manifestation of Acute Kidney Injury and Nephrotic Syndrome in a Patient with TAFRO syndrome.

    Science.gov (United States)

    Ito, Seigo; Uchida, Takahiro; Itai, Hiroki; Yamashiro, Aoi; Yamagata, Akira; Matsubara, Hidehito; Imakiire, Toshihiko; Shimazaki, Hideyuki; Kumagai, Hiroo; Oshima, Naoki

    2018-06-06

    A 76-year-old woman suddenly developed anasarca and a fever, and an examination revealed thrombocytopenia, reticulin fibrosis, and acute kidney injury, yielding the diagnosis of TAFRO syndrome. Renal replacement therapy and steroid treatment were soon started. Her proteinuria was minor at first; however, once the kidney function improved, nephrotic syndrome occurred. A kidney biopsy showed membranoproliferative glomerulonephritis-like glomerulopathy with massive macrophage infiltration. Although kidney dysfunction is often observed in TAFRO syndrome patients, its detailed mechanism is unclear. This case suggests that TAFRO syndrome involves both acute kidney injury with minor proteinuria and nephrotic syndrome, and these disorders can develop serially in the same patient.

  7. Handbook of serial communications interfaces a comprehensive compendium of serial digital input/output (I/O) standards

    CERN Document Server

    Frenzel, Louis

    2015-01-01

    This book catalogs the most popular and commonly used serial-port interfaces and provides details on the specifications and the latest standards, enabling you to select an interface for a new design or verify that an interface is working correctly. Each chapter is based on a different interface and is written in an easy to follow, standard format. With this book you will learn: The most widely used serial interfacesHow to select the best serial interface for a specific application or designThe trade-offs between data rate and distance (length or range)The operation and benefits of serial

  8. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  9. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  10. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  11. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  13. Vasculites e eosinófilos em biópsia endomiocárdica, como preditores de rejeição em transplante cardíaco Vasculitis y eosinófilos en biopsia endomiocárdica, como predictores de rechazo en transplante cardíaco Vasculitides and eosinophils in emdomyocardial biopsies as rejection predictors in heart transplantation

    Directory of Open Access Journals (Sweden)

    Reginaldo Cipullo

    2011-08-01

    precedieron rechazo agudo; y (2 Biopsias no predictoras: aquellas que no precedieron rechazo agudo. Comparamos la ocurrencia de los siguientes hallazgos histológicos: vasculitis, lesiones isquémicas, efecto Quilty y eosinófilos por análisis uni y multivariado entre los grupos. RESULTADOS: Después de análisis estadístico se verificó la presencia de vasculitis intensa y de eosinófilos como mayores predictores para rechazo agudo futuro, presentando respectivamente las siguientes razones de posibilidad: 10,60 (IC95%: 3,62 - 31,06. p BACKGROUND: The clinical significance of vasculitides, ischemic lesions, Quilty effect and the presence of eosinophils in endomyocardial biopsies of heart transplantation recipients with mild rejection has yet to be established. OBJECTIVE: To verify whether these histological findings observed in endomyocardial biopsies (eosinophils, vasculitides, Quilty effect and ischemic lesions are capable of predicting acute graft rejection. METHODS: A total of 1,012 consecutive endomyocardial biopsies were reevaluated; of these, 939 were classified as OR or 1R according to the Nomenclature of the International Society of Heart and Lung Transplantation of 2005 and divided in two groups: (1 Predictive biopsies: those that preceded acute rejection; and (2 Nonpredictive biopsies: those that did not precede acute rejection. We compared the occurrence of the following histological findings: vasculitides, ischemic lesions, Quilty effect and eosinophils between the groups by uni- and multivariate analyses. RESULTS: The statistical analysis showed that the presence of severe vasculitides and eosinophils were the best predictors for future acute rejection, with the following odds ratios: 10.60 (95%CI: 3.62 - 31.06. p < 0.001 and 6.26 (95%CI: 3.16 - 12.43, p < 0.001. CONCLUSION: Severe vasculitides and eosinophils in myocardial biopsies are the main predictive factors of acute graft rejection post-heart transplantation.

  14. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  15. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  16. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  17. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  18. Reframing Serial Murder Within Empirical Research.

    Science.gov (United States)

    Gurian, Elizabeth A

    2017-04-01

    Empirical research on serial murder is limited due to the lack of consensus on a definition, the continued use of primarily descriptive statistics, and linkage to popular culture depictions. These limitations also inhibit our understanding of these offenders and affect credibility in the field of research. Therefore, this comprehensive overview of a sample of 508 cases (738 total offenders, including partnered groups of two or more offenders) provides analyses of solo male, solo female, and partnered serial killers to elucidate statistical differences and similarities in offending and adjudication patterns among the three groups. This analysis of serial homicide offenders not only supports previous research on offending patterns present in the serial homicide literature but also reveals that empirically based analyses can enhance our understanding beyond traditional case studies and descriptive statistics. Further research based on these empirical analyses can aid in the development of more accurate classifications and definitions of serial murderers.

  19. Female serial killing: review and case report.

    Science.gov (United States)

    Frei, Andreas; Völlm, Birgit; Graf, Marc; Dittmann, Volker

    2006-01-01

    Single homicide committed by women is rare. Serial killing is very infrequent, and the perpetrators are usually white, intelligent males with sadistic tendencies. Serial killing by women has, however, also been described. To conduct a review of published literature on female serial killers and consider its usefulness in assessing a presenting case. A literature review was conducted, after searching EMBASE, MEDLINE and PsycINFO. The presenting clinical case is described in detail in the context of the literature findings. Results The literature search revealed few relevant publications. Attempts to categorize the phenomenon of female serial killing according to patterns of and motives for the homicides have been made by some authors. The most common motive identified was material gain or similar extrinsic gratification while the 'hedonistic' sadistic or sexual serial killer seems to be extremely rare in women. There is no consistent theory of serial killing by women, but psychopathic personality traits and abusive childhood experiences have consistently been observed. The authors' case did not fit the description of a 'typical' female serial killer. In such unusual circumstances as serial killing by a woman, detailed individual case formulation is required to make sense of the psychopathology in each case. Publication of cases in scientific journals should be encouraged to advance our understanding of this phenomenon. Copyright (c) 2006 John Wiley & Sons, Ltd.

  20. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  1. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  2. A comparison of the clinical, haemodynamic and angiographic features in right ventricular endomyocardial fibrosis and Ebstein's anomaly of the tricuspid valve.

    Science.gov (United States)

    Balakrishnan, K G; Sapru, R P; Sasidharan, K; Venkitachalam, C G

    1982-01-01

    The clinical, haemodynamic and angiographic features of 18 patients with right ventricular endomyocardial fibrosis (RVEMF) and 8 patients with Ebstein's anomaly of the tricuspid valve (EATV) have been compared. Diagnosis was confirmed by selective angiography. The position of the tricuspid annulus was identified from selective right ventricular angiograms and confirmed by selective right coronary angiography. In 83% of RVEMF patients the tricuspid annulus was displaced to the left of the spine. A false impression of displacement of the tricuspid leaflet can thus be created. However, a tricuspid leaflet displaced away from the tricuspid annulus was found only in patients with EATV. A considerable overlap exists between the wide spectrum of clinical presentations of the two conditions. Helpful distinguishing features that favour EATV were, the presence of a scratchy diastolic murmur and polyphasic QRS complexes in the ECG. Atrial fibrillation in the ECG, and myocardial calcification or pericardial effusion, whenever present, favour RVEMF.

  3. Live changes in muscle glycogen concentration of steers due to feeding and fasting as determined through serial biopsies of the Longissimus dorsi muscle

    Directory of Open Access Journals (Sweden)

    Ariel Apaoblaza

    2014-03-01

    Full Text Available Insufficient glycogen content in bovine muscle at slaughter produces meat with high final pH (> 5.8 which is undesirable. The objective of this study was to determine through biopsies the live changes in muscle glycogen concentration (MGC of housed steers fed on hay or hay plus energy concentrate for 30 d and then determine the effect of food deprivation (fasting for 24 h on the same variable. Ten steers of similar age, weight, and phenotypic characteristics were housed in individual pens and randomly assigned to two feeding treatments: ad libitum hay only (H, n = 5 and ad libitum hay plus flaked corn (Zea mays L. (HC, n = 5. Biopsies (B were taken from the Longissimus dorsi muscle at four occasions: the day before the start of experiment (B0, after 15 d (Bl, after 30 d (B2, and fasted for 24 h after B2 (B3. Before each biopsy, steers were sedated with xylazine (0.03 mL kg-1 and lidocaine was applied locally; samples were frozen in liquid nitrogen to determine MGC. Results showed a significant (P H and also of time (B2 > Bl on MGC; the decrease in MGC of steers due to fasting (B2 vs. B3 was not significant (P > 0.05. It was concluded that muscle biopsies allowed to detect a difference in the increase of MGC in steers fed an energy supplementation compared to steers fed hay only, and that fasting for 24 h tended to reduce MGC in both groups.

  4. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  5. The eyeball killer: serial killings with postmortem globe enucleation.

    Science.gov (United States)

    Coyle, Julie; Ross, Karen F; Barnard, Jeffrey J; Peacock, Elizabeth; Linch, Charles A; Prahlow, Joseph A

    2015-05-01

    Although serial killings are relatively rare, they can be the cause of a great deal of anxiety while the killer remains at-large. Despite the fact that the motivations for serial killings are typically quite complex, the psychological analysis of a serial killer can provide valuable insight into how and why certain individuals become serial killers. Such knowledge may be instrumental in preventing future serial killings or in solving ongoing cases. In certain serial killings, the various incidents have a variety of similar features. Identification of similarities between separate homicidal incidents is necessary to recognize that a serial killer may be actively killing. In this report, the authors present a group of serial killings involving three prostitutes who were shot to death over a 3-month period. Scene and autopsy findings, including the unusual finding of postmortem enucleation of the eyes, led investigators to recognize the serial nature of the homicides. © 2015 American Academy of Forensic Sciences.

  6. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  7. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  8. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  9. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  10. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  11. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  12. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  13. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  14. “It’s Always the Same, and It’s Always Different” Mythologisation and the Serial Killer in Henry: Portrait of a Serial Killer.

    OpenAIRE

    Smyth, David A.

    2015-01-01

    Serial killers are important in American horror because of their ability to exist between ‘myth’ and ‘reality’. The serial killer is one of the most important American myths, but it is one firmly rooted in real life: unlike Paul Bunyan or Superman, serial killers do exist. This essay examines the relationship between the ‘myth’ and the ‘reality’ of serial killers, and the complex relationship between the American public and the serial killer, using Henry: Portrait of a Serial K...

  15. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  16. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  17. Time-dependent changes in B-type natriuretic peptide after heart transplantation: correlation with allograft rejection and function.

    Science.gov (United States)

    Bader, Feras M; Rogers, R Kevin; Kfoury, Abdallah G; Gilbert, Edward M; Horne, Ben D; Stehlik, Josef; Renlund, Dale G

    2009-01-01

    Endomyocardial biopsy is the gold standard to diagnose cardiac allograft rejection, although a noninvasive modality such as brain natriuretic peptide (BNP) is attractive. The authors examined the correlation of BNP levels with rejection patterns and allograft function in cardiac allograft recipients followed up to 8 years. One hundred forty-four consecutive patients underwent endomyocardial biopsy, right heart catheterization, and blood sampling. BNP levels decreased during the first 6 months after transplant but then reached a plateau. Time-dependent correlations were made between BNP levels and allograft rejection, left ventricular ejection fraction, pulmonary capillary wedge pressure, right atrial pressure, and serum creatinine. BNP levels were not different between patients with any rejection pattern and no rejection prior to or after 6 months following transplant. BNP levels did not correlate with ejection fraction, pulmonary capillary wedge pressure, right atrial pressure, or creatinine in the first 6 months after transplant. Statistically significant correlations existed between BNP and these parameters after 6 months following transplant. In cardiac transplant recipients, BNP levels decrease in the first 6 months following transplant and then reach a plateau regardless of the presence, type, or severity of allograft rejection. BNP levels do predict allograft rejection but correlate with allograft function after 6 months following transplant.

  18. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  19. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  20. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  1. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  2. Spontaneous Tricuspid Valve Chordal Rupture in Idiopathic Pulmonary Hypertension.

    Science.gov (United States)

    Rodrigues, Ana Clara Tude; Afonso, José E; Cordovil, Adriana; Monaco, Claudia; Piveta, Rafael; Cordovil, Rodrigo; Fischer, Claudio H; Vieira, Marcelo; Lira-Filho, Edgar; Morhy, Samira S

    2016-03-01

    Rupture of tricuspid valve is unusual, occurring mainly in the setting of blunt trauma or endomyocardial biopsy. Spontaneous tricuspid valve chordal rupture is particularly rare. We report herein a case of a patient with severe pulmonary hypertension, on the lung transplantation waiting list, who presented with spontaneous chordal rupture, exacerbation of tricuspid insufficiency and worsening of clinical status. Diagnosis and treatment, along with possible mechanisms for this complication, are discussed. © 2015, Wiley Periodicals, Inc.

  3. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  4. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate- 99m Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate- 99m Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders. Cardiac

  5. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  6. Combined colonoscopy and endometrial biopsy cancer screening results in women with Lynch syndrome.

    Science.gov (United States)

    Nebgen, Denise R; Lu, Karen H; Rimes, Sue; Keeler, Elizabeth; Broaddus, Russell; Munsell, Mark F; Lynch, Patrick M

    2014-10-01

    Endometrial biopsy (EMBx) and colonoscopy performed under the same sedation is termed combined screening and has been shown to be feasible and to provide a less painful and more satisfactory experience for women with Lynch syndrome (LS). However, clinical results of these screening efforts have not been reported. The purpose of this study was to evaluate the long-term clinical outcomes and patient compliance with serial screenings over the last 10.5 years. We retrospectively analyzed the data for 55 women with LS who underwent combined screening every 1-2 years between 2002 and 2013. Colonoscopy and endometrial biopsy were performed by a gastroenterologist and a gynecologist, with the patient under conscious sedation. Out of 111 screening visits in these 55 patients, endometrial biopsies detected one simple hyperplasia, three complex hyperplasia, and one endometrioid adenocarcinoma (FIGO Stage 1A). Seventy-one colorectal polyps were removed in 29 patients, of which 29 were tubular adenomas. EMBx in our study detected endometrial cancer in 0.9% (1/111) of surveillance visits, and premalignant hyperplasia in 3.6% (4/111) of screening visits. No interval endometrial or colorectal cancers were detected. Combined screening under sedation is feasible and less painful than EMBx alone. Our endometrial pathology detection rates were comparable to yearly screening studies. Our results indicate that screening of asymptomatic LS women with EMBx every 1-2 years, rather than annually, is effective in the early detection of (pre)cancerous lesions, leading to their prompt definitive management, and potential reduction in endometrial cancer. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  8. Serial interprocessor communications system

    International Nuclear Information System (INIS)

    Labiak, W.; Siemens, P.; Bailey, C.

    1980-01-01

    A serial communications system based on the EIA RS232-C standard with modem control lines has been developed. The DLV11-E interface is used for this purpose. All handshaking is done with the modem control lines. This allows totally independent full duplex communication. The message format consists of eight bit data with odd parity and a sixteen bit checksum on the whole message. All communications are fully interrupt driven. A program was written to load a program into a remote LSI-11 using the serial line without bootstrap ROM

  9. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  10. A Survey of Electronic Serials Managers Reveals Diversity in Practice

    Directory of Open Access Journals (Sweden)

    Laura Costello

    2014-09-01

    Full Text Available A Review of: Branscome, B. A. (2013. Management of electronic serials in academic libraries: The results of an online survey. Serials Review, 39(4, 216-226. http://dx.doi.org/10.1016/j.serrev.2013.10.004 Abstract Objective – To examine industry standards for the management of electronic serials and measure the adoption of electronic serials over print. Design – Survey questionnaire. Setting – Email lists aimed at academic librarians working in serials management. Subjects – 195 self-selected subscribers to serials email lists. Methods – The author created a 20 question survey that consisted primarily of closed-ended questions pertaining to the collection demographics, staff, budget, and tools of serials management groups in academic libraries. The survey was conducted via Survey Monkey and examined using the analytical features of the tool. Participants remained anonymous and the survey questions did not ask them to reveal identifiable information about their libraries. Main Results – Collection demographics questions revealed that 78% of surveyed librarians estimated that print-only collections represented 40% or fewer of their serials holdings. The author observed diversity in the factors that influence print to digital transitions in academic libraries. However 71.5% of participants indicated that publisher technology support like IP authentication was required before adopting digital subscriptions. A lack of standardization also marked serials workflows, department responsibilities, and department titles. The author did not find a correlation between serials budget and the enrollment size of the institution. Participants reported that they used tools from popular serials management vendors like Serials Solutions, Innovative Interfaces, EBSCO, and Ex Libris, but most indicated that they used more than one tool for serials management. Participants specified 52 unique serials management products used in their libraries. Conclusion

  11. Criminal psychological profiling of serial arson crimes.

    Science.gov (United States)

    Kocsis, Richard N; Cooksey, Ray W

    2002-12-01

    The practice of criminal psychological profiling is frequently cited as being applicable to serial arson crimes. Despite this claim, there does not appear to be any empirical research that examines serial arson offence behaviors in the context of profiling. This study seeks to develop an empirical model of serial arsonist behaviors that can be systematically associated with probable offender characteristics. Analysis has produced a model of offence behaviors that identify four discrete behavior patterns, all of which share a constellation of common nondiscriminatory behaviors. The inherent behavioral themes of each of these patterns are explored with discussion of their broader implications for our understanding of serial arson and directions for future research.

  12. CMOS serial link for fully duplexed data communication

    Science.gov (United States)

    Lee, Kyeongho; Kim, Sungjoon; Ahn, Gijung; Jeong, Deog-Kyoon

    1995-04-01

    This paper describes a CMOS serial link allowing fully duplexed 500 Mbaud serial data communication. The CMOS serial link is a robust and low-cost solution to high data rate requirements. A central charge pump PLL for generating multiphase clocks for oversampling is shared by several serial link channels. Fully duplexed serial data communication is realized in the bidirectional bridge by separating incoming data from the mixed signal on the cable end. The digital PLL accomplishes process-independent data recovery by using a low-ratio oversampling, a majority voting, and a parallel data recovery scheme. Mostly, digital approach could extend its bandwidth further with scaled CMOS technology. A single channel serial link and a charge pump PLL are integrated in a test chip using 1.2 micron CMOS process technology. The test chip confirms upto 500 Mbaud unidirectional mode operation and 320 Mbaud fully duplexed mode operation with pseudo random data patterns.

  13. The Productivity Advantage of Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Shaw, Kathryn L.; Sørensen, Anders

    Serial entrepreneurs, who open more than one business, are found to have higher sales and higher productivity than novice entrepreneurs, who open one business. Using panel data on entrepreneurs and their firms from Denmark for 2001-2013, the serial entrepreneur has 67% higher sales than the novice......, but also opens firms that are larger in terms of the initial capital and labor, and thus is 39% more productive. There are subsets of firms that perform especially well – serial entrepreneurs that hold a portfolio of overlapping ongoing firms perform the best, as do those that open as limited liability...

  14. The American Serialization of Lord Jim

    Directory of Open Access Journals (Sweden)

    Stephen Donovan

    2017-12-01

    Full Text Available This essay presents the discovery of the American serialization of Joseph Conrad’s Lord Jim in New York’s Evening Telegram in 1903. This ‘lost’ serialization, it argues, invites a new perspective on Conrad’s early career by foregrounding the role of newspaper serialization and syndication in establishing his literary standing. After surveying the principal differences in the respective reading experiences of the periodical versus the book, it concludes by proposing that the prominence of women among Conrad’s first audiences requires us to reassess the basis for his success in North America and elsewhere.

  15. Broad ion beam serial section tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, B., E-mail: b.winiarski@manchester.ac.uk [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Materials Division, National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Gholinia, A. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Mingard, K.; Gee, M. [Materials Division, National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Thompson, G.E.; Withers, P.J. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom)

    2017-01-15

    Here we examine the potential of serial Broad Ion Beam (BIB) Ar{sup +} ion polishing as an advanced serial section tomography (SST) technique for destructive 3D material characterisation for collecting data from volumes with lateral dimensions significantly greater than 100 µm and potentially over millimetre sized areas. Further, the associated low level of damage introduced makes BIB milling very well suited to 3D EBSD acquisition with very high indexing rates. Block face serial sectioning data registration schemes usually assume that the data comprises a series of parallel, planar slices. We quantify the variations in slice thickness and parallelity which can arise when using BIB systems comparing Gatan PECS and Ilion BIB systems for large volume serial sectioning and 3D-EBSD data acquisition. As a test case we obtain 3D morphologies and grain orientations for both phases of a WC-11%wt. Co hardmetal. In our case we have carried out the data acquisition through the manual transfer of the sample between SEM and BIB which is a very slow process (1–2 slice per day), however forthcoming automated procedures will markedly speed up the process. We show that irrespective of the sectioning method raw large area 2D-EBSD maps are affected by distortions and artefacts which affect 3D-EBSD such that quantitative analyses and visualisation can give misleading and erroneous results. Addressing and correcting these issues will offer real benefits when large area (millimetre sized) automated serial section BIBS is developed. - Highlights: • In this work we examine how microstructures can be reconstructed in three-dimensions (3D) by serial argon broad ion beam (BIB) milling, enabling much larger volumes (>250×250×100µm{sup 3}) to be acquired than by serial section focused ion beam-scanning electron microscopy (FIB-SEM). • The associated low level of damage introduced makes BIB milling very well suited to 3D-EBSD acquisition with very high indexing rates. • We explore

  16. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  17. CD16+ Monocytes and Skewed Macrophage Polarization toward M2 Type Hallmark Heart Transplant Acute Cellular Rejection.

    Science.gov (United States)

    van den Bosch, Thierry P P; Caliskan, Kadir; Kraaij, Marina D; Constantinescu, Alina A; Manintveld, Olivier C; Leenen, Pieter J M; von der Thüsen, Jan H; Clahsen-van Groningen, Marian C; Baan, Carla C; Rowshani, Ajda T

    2017-01-01

    During acute heart transplant rejection, infiltration of lymphocytes and monocytes is followed by endothelial injury and eventually myocardial fibrosis. To date, no information is available on monocyte-macrophage-related cellular shifts and their polarization status during rejection. Here, we aimed to define and correlate monocyte-macrophage endomyocardial tissue profiles obtained at rejection and time points prior to rejection, with corresponding serial blood samples in 25 heart transplant recipients experiencing acute cellular rejection. Additionally, 33 healthy individuals served as control. Using histology, immunohistochemistry, confocal laser scan microscopy, and digital imaging expression of CD14, CD16, CD56, CD68, CD80, and CD163 were explored to define monocyte and macrophage tissue profiles during rejection. Fibrosis was investigated using Sirius Red stainings of rejection, non-rejection, and 1-year biopsies. Expression of co-stimulatory and migration-related molecules on circulating monocytes, and production potential for pro- and anti-inflammatory cytokines were studied using flow cytometry. At tissue level, striking CD16+ monocyte infiltration was observed during rejection ( p  rejection compared to barely present CD68+CD80+ M1 macrophages. Rejection was associated with severe fibrosis in 1-year biopsies ( p  rejection status, decreased frequencies of circulating CD16+ monocytes were found in patients compared to healthy individuals. Rejection was reflected by significantly increased CD54 and HLA-DR expression on CD16+ monocytes with retained cytokine production potential. CD16+ monocytes and M2 macrophages hallmark the correlates of heart transplant acute cellular rejection on tissue level and seem to be associated with fibrosis in the long term.

  18. Serial Position Functions in General Knowledge

    Science.gov (United States)

    Kelley, Matthew R.; Neath, Ian; Surprenant, Aimée M.

    2015-01-01

    Serial position functions with marked primacy and recency effects are ubiquitous in episodic memory tasks. The demonstrations reported here explored whether bow-shaped serial position functions would be observed when people ordered exemplars from various categories along a specified dimension. The categories and dimensions were: actors and age;…

  19. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  20. EMMPRIN and its ligand cyclophilin A as novel diagnostic markers in inflammatory cardiomyopathy.

    Science.gov (United States)

    Seizer, Peter; Geisler, Tobias; Bigalke, Boris; Schneider, Martin; Klingel, Karin; Kandolf, Reinhard; Stellos, Konstantinos; Schreieck, Jürgen; Gawaz, Meinrad; May, Andreas E

    2013-03-10

    During inflammatory cardiomyopathy matrix metalloproteinases are crucially involved in cardiac remodeling. The aim of the present study was to investigate whether the "extracellular matrix metalloproteinase inducer" EMMPRIN (CD147) and its ligand Cyclophilin A (CyPA) are upregulated in inflammatory cardiomyopathy and may serve as diagnostic markers. Therefore, a series of 102 human endomyocardial biopsies were analyzed for the expression of EMMPRIN and CyPA and correlated with histological and immunohistological findings. Endomyocardial biopsies were stained for EMMPRIN and CyPA in addition to standard histology (HE, Trichrom) and immunohistological stainings (MHC-II, CD68, CD3). 39 (38.2%) biopsies met the immunohistological criteria of an inflammatory cardiomyopathy. EMMPRIN, which was predominantly expressed on cardiomyocytes, was slightly (but significantly) upregulated in non inflammatory cardiomyopathies compared to normal histopathological findings and highly upregulated in inflammatory cardiomyopathy compared to both non inflammatory cardiomyopathy and normal histopathology. In contrast, CyPA reveals no enhanced expression in non inflammatory cardiomyopathies and a highly enhanced expression in inflammatory cardiomyopathy, where it is closely associated with leucocytes infiltrates. We found a strong correlation between both EMMPRIN and CyPA with the expression of MHC-II molecules (correlation coefficient 0.475 and 0.527, pEMMPRIN and CyPA with CD68 (correlation coefficient 0.393 and 0.387, pEMMPRIN is enhanced in both inflammatory and non inflammatory cardiomyopathies and can serve as a marker of myocardial remodeling. CyPA may represent a novel and specific marker for cardiac inflammation. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. [B-type natriuretic peptide assessment in the diagnosis of rejection after pediatric heart transplant].

    Science.gov (United States)

    Sylos, Cristina de; Azeka, Estela; Kajita, Luis; Benvenutti, Luis; Strunz, Célia Cassaro; Branco, Klébia Castello; Riso, Arlindo Almeida; Tanamati, Carla; Jatene, Marcelo; Barbero-Marcial, Miguel

    2009-03-01

    Rejection is one of the major causes of mortality following pediatric heart transplant. B-type natriuretic peptide (BNP) has been studied as a method for the diagnosis of acute rejection, especially in adult patients undergoing heart transplant. To correlate serum BNP levels with acute rejection as diagnosed by endomyocardial biopsy in patients of the pediatric heart transplant group. A total of 50 BNP samples were collected from 33 children in the postoperative period of heart transplant, and data on age, gender, skin color, blood group, immune panel, follow-up time after transplant, functional class, immunosuppressive regimen used and number of rejections were analyzed. Thirty three children with median age of 10.13 years were analyzed; of these, 54% were females and 78% were Caucasians. BNP levels were determined at a mean time from transplant of 4.25 years. Nine episodes of rejection were diagnosed in eight patients (27%) by means of endomyocardial biopsy; of these, three were grade 3A, five were grade 2, and one had humoral rejection. At the moment of biopsy, most patients were asymptomatic. The mean serum BNP level was 77.18 pg/ml, with 144.22 pg/ml in the group with rejection and 62.46 pg/ml in the group without rejection, with p = 0.02. Asymptomatic children can present acute rejection in the postoperative period of heart transplant. Serum BNP levels show a statistically significant difference in the group with rejection and thus can be an additional method in the diagnosis of cardiac rejection.

  2. Serial Entrepreneurship, Learning by Doing and Self-selection

    DEFF Research Database (Denmark)

    Rocha, Vera; Carneiro, Anabela; Varum, Celeste

    2015-01-01

    of the person-specific effect, using information on individuals’ past histories in paid employment, confirm that serial entrepreneurs exhibit, on average, a larger person-specific effect than non-serial business owners. Moreover, ignoring serial entrepreneurs’ self-selection overestimates learning by doing......It remains a question whether serial entrepreneurs typically perform better than their novice counterparts owing to learning by doing effects or mostly because they are a selected sample of higher-than-average ability entrepreneurs. This paper tries to unravel these two effects by exploring a novel...... empirical strategy based on continuous time duration models with selection. We use a large longitudinal matched employer-employee dataset that allows us to identify about 220,000 individuals who have left their first entrepreneurial experience, out of which over 35,000 became serial entrepreneurs. We...

  3. Analysis of assembly serial number usage in domestic light-water reactors

    International Nuclear Information System (INIS)

    Reich, W.J.; Moore, R.S.

    1991-05-01

    Domestic light-water reactor (LWR) fuel assemblies are identified by a serial number that is placed on each assembly. These serial numbers are used as identifiers throughout the life of the fuel. The uniqueness of assembly serial numbers is important in determining their effectiveness as unambiguous identifiers. The purpose of this study is to determine what serial numbering schemes are used, the effectiveness of these schemes, and to quantify how many duplicate serial numbers occur on domestic LWR fuel assemblies. The serial numbering scheme adopted by the American National Standards Institute (ANSI) ensures uniqueness of assembly serial numbers. The latest numbering scheme adopted by General Electric (GE), was also found to be unique. Analysis of 70,971 fuel assembly serial numbers from permanently discharged fuel identified 11,948 serial number duplicates. Three duplicate serial numbers were found when analysis focused on duplication within the individual fuel inventory at each reactor site, but these were traced back to data entry errors and will be corrected by the Energy Information Administration (EIA). There were also three instances where the serial numbers used to identify assemblies used for hot cell studies differed from the serial numbers reported to the EIA. It is recommended that fuel fabricators and utilities adhere to the ANSI serial numbering scheme to ensure serial number uniqueness. In addition, organizations collecting serial number information, should request that all known serial numbers physically attached or associated with each assembly be reported and identified by the corresponding number scheme. 10 refs., 5 tabs

  4. Implementation of a Multichannel Serial Data Streaming Algorithm using the Xilinx Serial RapidIO Solution

    Science.gov (United States)

    Doxley, Charles A.

    2016-01-01

    In the current world of applications that use reconfigurable technology implemented on field programmable gate arrays (FPGAs), there is a need for flexible architectures that can grow as the systems evolve. A project has limited resources and a fixed set of requirements that development efforts are tasked to meet. Designers must develop robust solutions that practically meet the current customer demands and also have the ability to grow for future performance. This paper describes the development of a high speed serial data streaming algorithm that allows for transmission of multiple data channels over a single serial link. The technique has the ability to change to meet new applications developed for future design considerations. This approach uses the Xilinx Serial RapidIO LOGICORE Solution to implement a flexible infrastructure to meet the current project requirements with the ability to adapt future system designs.

  5. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  6. SERIAL TELEVISI DEXTER SEBAGAI ANAKRONISME DALAM SASTRA POPULER

    Directory of Open Access Journals (Sweden)

    Ida Rochani Adi

    2014-06-01

    Full Text Available In the popular literature context, this study aims to investigate: (1 how the formulation of the characterization of Dexter in the television serial Dexter violates the tradition of literary characterization, and (2 how the formula of moral values is dramatized through Dexter, who is a sociopath, psychopath, serial killer, and person without moral. The research object was the television serial Dexter, which ranks five in popularity in the world. The data were collected by documenting 84 episodes of the serial having been broadcast since 2006. They were analyzed by means of content analysis and qualitative descriptive techniques. Based on the findings, the conclusions are as follows. First, there is a violation or anachronism of characterization through the main character in the serial. Second, the dramatized moral values still contain conventional values although they are in different forms.

  7. Reconstructing genealogies of serial samples under the assumption of a molecular clock using serial-sample UPGMA.

    Science.gov (United States)

    Drummond, A; Rodrigo, A G

    2000-12-01

    Reconstruction of evolutionary relationships from noncontemporaneous molecular samples provides a new challenge for phylogenetic reconstruction methods. With recent biotechnological advances there has been an increase in molecular sequencing throughput, and the potential to obtain serial samples of sequences from populations, including rapidly evolving pathogens, is fast being realized. A new method called the serial-sample unweighted pair grouping method with arithmetic means (sUPGMA) is presented that reconstructs a genealogy or phylogeny of sequences sampled serially in time using a matrix of pairwise distances. The resulting tree depicts the terminal lineages of each sample ending at a different level consistent with the sample's temporal order. Since sUPGMA is a variant of UPGMA, it will perform best when sequences have evolved at a constant rate (i.e., according to a molecular clock). On simulated data, this new method performs better than standard cluster analysis under a variety of longitudinal sampling strategies. Serial-sample UPGMA is particularly useful for analysis of longitudinal samples of viruses and bacteria, as well as ancient DNA samples, with the minimal requirement that samples of sequences be ordered in time.

  8. Role of axillary sentinel lymph node biopsy in patients with pure ductal carcinoma in situ of the breast

    International Nuclear Information System (INIS)

    Zavagno, Giorgio; Capitanio, Giovanni; Ballarin, Andrea; Pierobon, Maria Elena; Marconato, Giorgia; Nitti, Donato; Carcoforo, Paolo; Marconato, Renato; Franchini, Zeno; Scalco, Giuliano; Burelli, Paolo; Pietrarota, Paolo; Lise, Mario; Mencarelli, Roberto

    2005-01-01

    Sentinel lymph node (SLN) biopsy is an effective tool for axillary staging in patients with invasive breast cancer. This procedure has been recently proposed as part of the treatment for patients with ductal carcinoma in situ (DCIS), because cases of undetected invasive foci and nodal metastases occasionally occur. However, the indications for SLN biopsy in DCIS patients are controversial. The aim of the present study was therefore to assess the incidence of SLN metastases in a series of patients with a diagnosis of pure DCIS. A retrospective evaluation was made of a series of 102 patients who underwent SLN biopsy, and had a final histologic diagnosis of pure DCIS. Patients with microinvasion were excluded from the analysis. The patients were operated on in five Institutions between 1999 and 2004. Subdermal or subareolar injection of 30–50 MBq of 99 m-Tc colloidal albumin was used for SLN identification. All sentinel nodes were evaluated with serial sectioning, haematoxylin and eosin staining, and immunohistochemical analysis for cytocheratin. Only one patient (0.98%) was SLN positive. The primary tumour was a small micropapillary intermediate-grade DCIS and the SLN harboured a micrometastasis. At pathologic revision of the specimen, no detectable focus of microinvasion was found. Our findings indicate that SLN metastases in pure DCIS are a very rare occurrence. SLN biopsy should not therefore be routinely performed in patients who undergo resection for DCIS. SLN mapping can be performed, as a second operation, in cases in which an invasive component is identified in the specimen. Only DCIS patients who require a mastectomy should have SLN biopsy performed at the time of breast operation, since in these cases subsequent node mapping is not feasible

  9. Delaware's first serial killer.

    Science.gov (United States)

    Inguito, G B; Sekula-Perlman, A; Lynch, M J; Callery, R T

    2000-11-01

    The violent murder of Shirley Ellis on November 29, 1987, marked the beginning of the strange and terrible tale of Steven Bryan Pennell's reign as the state of Delaware's first convicted serial killer. Three more bodies followed the first victim, and all had been brutally beaten and sadistically tortured. The body of a fifth woman has never been found. State and county police collaborated with the FBI to identify and hunt down their suspect, forming a task force of over 100 officers and spending about one million dollars. Through their knowledge and experience with other serial killers, the FBI was able to make an amazingly accurate psychological profile of Delaware's serial killer. After months of around-the-clock surveillance, Steven Pennell was arrested on November 29, 1988, one year to the day after the first victim was found. Pennell was found guilty in the deaths of the first two victims on November 29, 1989, and plead no contest to the murder of two others on October 30, 1991. Still maintaining his innocence, he asked for the death penalty so that he could spare his family further agony. Steven Pennell was executed by lethal injection on March 15, 1992.

  10. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  11. Classifying serial killers.

    Science.gov (United States)

    Promish, D I; Lester, D

    1999-11-08

    We attempted to match the appearance and demeanor of 27 serial killers to the postmortem 'signatures' found on their victims' bodies. Our results suggest that a link may exist between postmortem signatures and two complementary appearance-demeanor types.

  12. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  13. CAMAC serial highway interface for the LSI-11

    International Nuclear Information System (INIS)

    Lau, N.H.

    1980-01-01

    A CAMAC Serial Highway Interface has been designed for the Local Control and Instrumentation System of the Mirror Fusion Test Facility. There are over 50 distinguishable systems in the facility, each of which consists of the LSI-11 computer, fiber optic communication links, and the CAMAC system. The LSI-11 computer includes a 32k memory, serial modem interface and the CAMAC Serial Highway Interface

  14. Notorious Cases of Serial Killers

    Directory of Open Access Journals (Sweden)

    Iosub Elena-Cătălina

    2014-05-01

    Full Text Available The reconstruction of a death scene provides an overall picture of the crime and will indicate the murder as an event or one of a series of events and also the criminal. But when the criminal is declared a serial killer, many questions are raised up. How could a person kill some else without a reason or why people react in such a disorganized way and become so brutal or what made them act like that and so many questions with also so many answers. This project explains the psychology of a murderer, his own way of thinking and acting by presuming that we may accurately discover what is in their minds when they kill. It is about a very complex issue regarding murder investigations, biological factors and psychological profile of a serial killer. Dealing with this problem we will at last reach to the question that could solve finally the puzzle: ―Are serial murderers distorted reflections of society's own values?

  15. Modus operandi of female serial killers.

    Science.gov (United States)

    Wilson, W; Hilton, T

    1998-04-01

    The modus operandi of female serial killers was examined from a chronology of 58 cases in America and 47 cases in 17 other countries, compiled over 25-year intervals. Female serial killers in other countries accounted for a disproportionately greater number of victims, but those in America managed a longer killing career when associated with a low profile modus operandi.

  16. Detection and typing of human papillomaviruses in mucosal and cutaneous biopsies from immunosuppressed and immunocompetent patients and patients with epidermodysplasia verruciformis: a unified diagnostic approach.

    OpenAIRE

    Surentheran, T; Harwood, C A; Spink, P J; Sinclair, A L; Leigh, I M; Proby, C M; McGregor, J M; Breuer, J

    1998-01-01

    AIM: To develop a unified diagnostic approach for the detection of human papillomavirus (HPV) DNA in skin and mucosal biopsies from both immunocompetent and immunosuppressed individuals using a degenerate polymerase chain reaction (PCR) method. METHODS: The sensitivity and specificity of three published degenerate primer sets (HVP2/B5 and F14/B15; MY09/MY11; CP62/69 outer and CP65/68 nested primer pairs) were evaluated in PCR reactions with serial dilutions of 12 representative cloned HPV typ...

  17. Reliability and limitation of various diagnostic methods including nuclear medicine in myocardial disease

    International Nuclear Information System (INIS)

    Tokuyasu, Yoshiki; Kusakabe, Kiyoko; Yamazaki, Toshio

    1981-01-01

    Electrocardiography (ECG), echocardiography, nuclear method, cardiac catheterization, left ventriculography and endomyocardial biopsy (biopsy) were performed in 40 cases of cardiomyopathy (CM), 9 of endocardial fibroelastosis and 19 of specific heart muscle disease, and the usefulness and limitation of each method was comparatively estimated. In CM, various methods including biopsy were performed. The 40 patients were classified into 3 groups, i.e., hypertrophic (17), dilated (20) and non-hypertrophic.non-dilated (3) on the basis of left ventricular ejection fraction and hypertrophy of the ventricular wall. The hypertrophic group was divided into 4 subgroups: 9 septal, 4 apical, 2 posterior and 2 anterior. The nuclear study is useful in assessing the site of the abnormal ventricular thickening, perfusion defect and ventricular function. Echocardiography is most useful in detecting asymmetric septal hypertrophy. The biopsy gives the sole diagnostic clue, especially in non-hypertrophic.non-dilated cardiomyopathy. ECG is useful in all cases but correlation with the site of disproportional hypertrophy was not obtained. (J.P.N.)

  18. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  19. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  20. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  1. Plasma cytokine profile in tropical endomyocardial fibrosis: predominance of TNF-a, IL-4 and IL-10.

    Directory of Open Access Journals (Sweden)

    Aline S Bossa

    Full Text Available BACKGROUND: The participation of immune/inflammatory mechanisms in the pathogenesis of tropical endomyocardial fibrosis (EMF has been suggested by the finding of early blood and myocardial eosinophilia. However, the inflammatory activation status of late-stage EMF patients is still unknown. METHODOLOGY/PRINCIPAL FINDINGS: We evaluated pro- and anti-inflammatory cytokine levels in plasma samples from late stage EMF patients. Cytokine levels of Tumor Necrosis Factor (TNF-α, Interferon (IFN-γ, Interleukin (IL-2, IL-4, IL-6, and IL-10 were assayed in plasma samples from 27 EMF patients and compared with those of healthy control subjects. All EMF patients displayed detectable plasma levels of at least one of the cytokines tested. We found that TNF-α, IL-6, IL-4, and IL-10 were each detected in at least 74% of tested sera, and plasma levels of IL-10, IL-4, and TNF-α were significantly higher than those of controls. Plasma levels of such cytokines positively correlated with each other. CONCLUSIONS/SIGNIFICANCE: The mixed pro- and anti-inflammatory/Th2circulating cytokine profile in EMF is consistent with the presence of a persistent inflammatory stimulus. On the other hand, the detection of increased levels of TNF-α may be secondary to the cardiovascular involvement observed in these patients, whereas IL-4 and IL-10 may have been upregulated as a homeostatic mechanism to buffer both production and deleterious cardiovascular effects of pro-inflammatory cytokines. Further studies might establish whether these findings play a role in disease pathogenesis.

  2. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  3. Current Understanding of the Pathophysiology of Myocardial Fibrosis and Its Quantitative Assessment in Heart Failure

    Directory of Open Access Journals (Sweden)

    Tong Liu

    2017-04-01

    Full Text Available Myocardial fibrosis is an important part of cardiac remodeling that leads to heart failure and death. Myocardial fibrosis results from increased myofibroblast activity and excessive extracellular matrix deposition. Various cells and molecules are involved in this process, providing targets for potential drug therapies. Currently, the main detection methods of myocardial fibrosis rely on serum markers, cardiac magnetic resonance imaging, and endomyocardial biopsy. This review summarizes our current knowledge regarding the pathophysiology, quantitative assessment, and novel therapeutic strategies of myocardial fibrosis.

  4. SERIAL TELEVISI DEXTER SEBAGAI ANAKRONISME DALAM SASTRA POPULER

    OpenAIRE

    Ida Rochani Adi

    2014-01-01

    In the popular literature context, this study aims to investigate: (1) how the formulation of the characterization of Dexter in the television serial Dexter violates the tradition of literary characterization, and (2) how the formula of moral values is dramatized through Dexter, who is a sociopath, psychopath, serial killer, and person without moral. The research object was the television serial Dexter, which ranks five in popularity in the world. The data were collected by documenting 84 epi...

  5. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  6. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  7. Post-treatment biopsy results following permanent transrectal ultrasound-guided interstitial brachytherapy in early stage prostate cancer

    International Nuclear Information System (INIS)

    Prestidge, Bradley R.; Blasko, John C.; Grimm, Peter D.; Hoak, David C.; Cavanagh, Bill; Ragde, Haakon

    1995-01-01

    minimum peripheral dose of 115 Gy with a median activity of 123 mCi. Sextant biopsies were performed under transrectal ultrasound guidance as well as any focal hypoechoic areas on ultrasound. All biopsy specimens were examined by a single, genitourinary pathologist and classified as either 'negative', 'indeterminate', or 'positive' depending on cellular, architectural, and immunohistochemical criteria. RESULTS: At the time of last biopsy, 161 (80%) have achieved negative pathology (median follow-up 30.8 months). 34 patients (17%) had indeterminate biopsies (median follow-up 21.0 months), and 6 (3%) were positive (median follow-up 30.0 months). Positive, indeterminate, and negative biopsy results by stage were respectively: 51 T1 - 1 (2%), 11 (22%), and 39 (76%); 125 T2a - 3 (2%), 23 (18%), and 99 (79%); 25 T2b/c - 2 (8%), 0, and 23 (92%). Excluding 6 patients with distant relapse proven on bone scan, median PSA values at the time of post-implant biopsy according to biopsy category were: negative 0.2 (range 0.1-7.4), indeterminate 0.5 (range 0.1-2.2), and positive 8.1 (range 2.6-26) (p < 0.005). Only 2 of the 186 patients with a PSA <4.0 at the time of biopsy were positive. All 6 of the positive, 26 indeterminate, and 111 negative biopsies were treated with I-125. Among the 58 Pd-103 patients, none have had positive biopsies, 8 have been indeterminate, and 50 negative. Among those 33 patients with a biopsy interpreted as 'indeterminate' who had serial biopsies, 28 subsequently converted to negative, 1 to positive, and 4 have remained indeterminate. The number of biopsies classified as indeterminate were time-dependent comprising 33% (48/144) of biopsies taken between 12 and 18 months, decreasing to 14.2% (15/106) at 18-30 months, and 5% (1/19) for biopsies taken 54 or more months post-implant. CONCLUSION: These data demonstrate an 80% biopsy confirmed local control rate following permanent prostate implant. In addition, a higher local control rate will likely be attained

  8. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  9. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  10. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy

    International Nuclear Information System (INIS)

    Bahrs, S.D.; Hattermann, V.; Preibsch, H.; Hahn, M.; Staebler, A.; Claussen, C.D.; Siegmann-Luz, K.C.

    2014-01-01

    Aim: To evaluate whether another contrast-enhanced (CE) magnetic resonance imaging (MRI) examination 24–48 h after MRI-guided vacuum-assisted breast biopsy (MRI-VAB) can reduce the rate of false-negative cases. Materials and methods: The study included 252 patients who underwent MRI-VAB for the clarification of 299 lesions. The success of MRI-VAB was assessed at interventional MRI and another CE MRI 24–48 h after the intervention. In cases of successful MRI-VAB (complete or partial lesion removal) and benign histological results, follow-up breast MRI was performed. In cases of unsuccessful biopsy (unchanged lesion), tissue sampling was repeated. False-negative cases were calculated to assess the diagnostic value of MRI follow-up within 2 days after intervention. Results: Ninety-eight malignant (32.8%) and 201 (67.2%) benign lesions were diagnosed using MRI-VAB. At immediate unenhanced control MRI, all lesions were assessed as successfully biopsied. In 18 benign cases (6%), CE MRI after 24–48 h showed an unsuccessful intervention. Further tissue sampling revealed another 13 cancers in these patients. This results in a false-negative rate of 11.7%. Follow-up MRI of the benign lesions presented no further malignancy. Conclusions: MRI-VAB with immediate unenhanced control offers a success rate of 94%. The rate of false-negative biopsies (11.7%) could be reduced to zero by using short-term follow-up MRI. Therefore, a further CE breast MRI 24–48 h after benign MRI-VAB to eliminate missed cancers is recommended. - Highlights: • Some suspicious breast lesions are only seen on MRI. • They can be biopsied by a MRI-guided vacuum-assisted biopsy system. • Inadequate sampling causes some false-negative biopsies. • We evaluate an additional control MRI 24 to 48 hours after biopsy. • A reduced rate of the false-negative biopsies was found

  11. The Serial Murderer's Motivations: An Interdisciplinary Review.

    Science.gov (United States)

    DeHart, Dana D.; Mahoney, John M.

    1994-01-01

    Defines serial killer as individual who murders two or more victims over an extended period of time, ranging from days to years, with the crimes often being sexually motivated. Reviews existing motivational theories of serial murder and proposes additional explications from range of disciplines. Presents suggestions for future research and…

  12. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  13. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  14. From animal cruelty to serial murder: applying the graduation hypothesis.

    Science.gov (United States)

    Wright, Jeremy; Hensley, Christopher

    2003-02-01

    Although serial murder has been recorded for centuries, limited academic attention has been given to this important topic. Scholars have attempted to examine the causality and motivations behind the rare phenomenon of serial murder. However, scant research exists which delves into the childhood characteristics of serial murderers. Using social learning theory, some of these studies present supporting evidence for a link between childhood animal cruelty and adult aggression toward humans. Based on five case studies of serial murderers, we contribute to the existing literature by exploring the possible link between childhood cruelty toward animals and serial murder with the application of the graduation hypothesis.

  15. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  16. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    Science.gov (United States)

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  17. Serial Austen. Mashingups with Zombies

    Directory of Open Access Journals (Sweden)

    Eleonora Federici

    2017-01-01

    Full Text Available Jane Austen sells. She sells in all possible ways, her novels have been adapted for the cinema and the stage, they have been rewritten as comics and graphic novels. Jane austen is a cultural icon. The interest in her life is so strong that many biographies have been written in order to recover new facts and details. The places where she has lived and the places depicted in her novels have become tourist sites for literary pilgrims. Austen is a cross-over phenomenon, with regency costume balls recreated in her name and an endless proliferation of her works in all media. My essay will investigate Jane Austen and Seth Grahame-Smith’s Pride and Prejudice and Zombies (2009, a mash-up novel which has become a real cultural phenomenon of the last decade and will demonstrate how it can be considered a serial narrative. If as Henry Jenkins asserts, seriality implies the unfolding of a story over time through a process of “chunking” (that is creating meaningful parts of the same story and of “dispersal” (that is breaking the story into more parts and in more genres and media, mash-ups seems to do this.  Austen’s story remains as a “story hook” which pushes the reader to come back to different products for a continuation of the same story. So, if on the one hand, seriality occurs within the same text, the story-telling of Austen’s stories across genres and media is part of a seriality process.

  18. Sensing the Opaque : Seriality and the Aesthetics of Televisual Form

    NARCIS (Netherlands)

    Dasgupta, S.; Kelleter, F.

    2017-01-01

    Recent work on TV seriality focuses on the deference of meaning through narrative extension. Contemporary seriality, it has been argued, exploits this expanding textuality to construct complicated narratives that tip the pleasures of seriality toward detecting the meaning of the plot's

  19. Disease progression in usual interstitial pneumonia compared with desquamative interstitial pneumonia. Assessment with serial CT

    International Nuclear Information System (INIS)

    Hartman, T.E.; Primack, S.L.; Kang, E.Y.

    1997-01-01

    Objective. To determine the outcome of areas of ground-glass attenuation and assess disease progression on serial high-resolution CT (HRCT) scans of patients with biopsy specimen-proved usual interstitial pneumonia (UIP) and desquamative interstitial pneumonia (DIP). Materials and methods. Twelve patients with biopsy specimen-proved UIP and 11 patients with biopsy specimen-proved DIP who had initial and follow-up HRCT scans (median interval, 10 months) were reviewed. Eleven patients with UIP and 11 with DIP received treatment between the initial and follow-up CT scans. The scans were evaluated for the presence and extent of ground-glass attenuation, irregular linear opacities and honeycombing, and overall extent of parenchymal involvement. Results. On initial CT scans, all 12 patients with UIP had areas of ground-glass attenuation (mean±SD extent, 30±16%) and irregular lines (mean±SD extent, 17±7%) and 10 patients had honeycombing (mean±SD extent, 10±6%). All 11 patients with DIP had areas of ground-glass attenuation on initial HRCT scans (mean±SD extent, 51±26%), 5 patients had irregular linear opacities (mean±SD extent, 5±5%), and 1 patient had honeycombing. Nine of the 12 patients with UIP showed increase in the extent of ground-glass attenuation (n=6) or progression to irregular lines (n=2) or honeycombing (n=4) on follow-up as compared with only 2 patients with DIP who showed progression to irregular lines (n=1) or honeycombing (n=1) (p 2 test). Conclusion. In patients with UIP, areas of ground-glass attenuation usually increase in extent or progress to fibrosis despite treatment. Areas of ground-glass attenuation in most patients with DIP remain stable or improve with treatment. (authors)

  20. Serial private infrastructures

    NARCIS (Netherlands)

    van den Berg, V.A.C.

    2013-01-01

    This paper investigates private supply of two congestible infrastructures that are serial, where the consumer has to use both in order to consume. Four market structures are analysed: a monopoly and 3 duopolies that differ in how firms interact. It is well known that private supply leads too high

  1. Serial murder: An unusual stereotype.

    Science.gov (United States)

    Sane, Mandar R; Mugadlimath, Anand B; Farooqui, Jamebaseer M; Janagond, Anand B; Mishra, Pradeep K

    2017-12-01

    Serial murders attract attention from the media, mental health experts, academia, and the general public. We present a case of serial murders that took place in a limited area and which caused public anxiety and anguish in central India. All the victims were homeless beggars, who were bludgeoned to death (crush injury). Individual murders were initially investigated by different police stations; fortunately, since they sent all the bodies to a common autopsy centre, a forensic pathologist was able to link all the cases, the first person to do so. This emphasises the need for sharing information among police stations and autopsy centres.

  2. Child serial murder-psychodynamics: closely watched shadows.

    Science.gov (United States)

    Turco, R

    2001-01-01

    There is a malignant transformation in object relations resulting in an identification with an omnipotent and cruel object resulting in an identity transformation. If the tension, desperation, and dissociation increase, serial murder becomes spree murder. The presence of pathological narcissism and psychopathic tendencies are of diagnostic significance in understanding the murderer's personality functioning and motivation to kill. Meloy (1988) considered the degree of sadism and aggression combined with narcissistic qualities to reflect the "malignancy" of the psychopathic disturbance where gratification (of aggression) occurs in the service of narcissistic functioning--that is, cruelty toward others in the form of a triumphant victory over a rejecting object. Meloy also believes that dissociation is ubiquitious in the psychopath. The initial murder of the serial murderer may reflect a "new identity." The pathological object-relations of narcissism and the malignant narcissism are important diagnostic indicators in the personality functioning of serial killers and the occurrence of these phenomena is a significant factor in the formation of the personalities of serial killers, their inner motivations, and their pattern of commission.

  3. IMPLEMENTATION OF SERIAL AND PARALLEL BUBBLE SORT ON FPGA

    Directory of Open Access Journals (Sweden)

    Dwi Marhaendro Jati Purnomo

    2016-06-01

    Full Text Available Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort required smaller memory as well as utility compared to parallel bubble sort. Meanwhile, parallel bubble sort performed faster than serial bubble sort

  4. A high speed serializer ASIC for ATLAS Liquid Argon calorimeter upgrade

    CERN Document Server

    Liu, T; The ATLAS collaboration

    2011-01-01

    The current front-end electronics of the ATLAS Liquid Argon calorimeters need to be upgraded to sustain the higher radiation levels and data rates expected at the upgraded LHC machine (HL-LHC), which will have 5 times more luminosity than the LHC in its ultimate configuration. This upgrade calls for an optical link system of 100 Gbps per front-end board (FEB). A high speed, low power, radiation tolerant serializer is the critical component in this system. In this paper, we present the design and test results of a single channel 16:1 serializer and the design of a double-channel 16:1 serializer. Both designs are based on a commercial 0.25 μm silicon-on-sapphire CMOS technology. The single channel serializer consists of a serializing unit, a PLL clock generator and a line driver implemented in current mode logic (CML). The serializing unit multiplexes 16 bit parallel LVDS data into 1-bit width serial CMOS data. The serializing unit is composed of a cascade of 2:1 multiplexing circuits based on static D-flip-fl...

  5. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  6. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  7. [The serial murder: a few theoretical perspectives].

    Science.gov (United States)

    Leistedt, S; Linkowski, P

    2011-01-01

    Despite numbers of publications and effort to try to establish the definition, the classification, the epidemiology, the clinical aspects and the psychopathology of serial killers, a universal consensus seems to say the least. Crime, though reduced in some countries, appears to impact more and more consistent worldwide, generating controversial ideas and a multitude of possible explanations. The serial killer usually presents as a caucasian man, aged between 20 and 40 years, often embedded socially and in his family, but with serious psychiatric, personal and especially family history. Usually acting alone, the serial killer plans a crime well in advance, but sometimes within the scope of impulsivity for a minority, the victim not being previously selected. In the latter case, an actual mental illness like psychosis is found. It is clear from numerous psychopathological studies conducted so far that most serial killers are defined as psychopathic sexual sadists, whose childhood was difficult, if not flouted, punctuated by physical and psychological violence situations. In addition, pervasive fantasies combined with thoughts of death, sex and violence are as much in common with the original acts of which they are the instigators. Beyond a relentless media that is constantly watering the public with stories and pictures depicting them as such, serial killers remain an enigma. We can therefore attempt to answer the various questions raised by this phenomenon, the way these people operate and how we can curb the rise, thanks to the neurobiological and neurophysiological approaches that science offers us.

  8. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  9. Failure to diagnose cardiac treatment rejection with Tc99m-PYP images

    International Nuclear Information System (INIS)

    McKillop, J.H.; McDougall, I.R.; Goris, M.L.; Mason, J.W.; Reitz, B.A.

    1981-01-01

    The possibility of diagnosing transplant rejection using Tc-99m-PYP imaging was examined in 12 cardiac transplant recipients. Two patients were studied on two occasions. The presence or absence of active rejection was established by endomyocardial biopsy. The intensity and pattern of myocardial uptake of the tracer did not differ significantly in the two patients studied at the time of rejection compared to the remainder. It is concluded that a single Tc-99m-PYP study cannot be used to diagnose cardiac transplant rejection

  10. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  11. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  12. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    International Nuclear Information System (INIS)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G.; Lemos, Gustavo C.; Baroni, Ronaldo H.

    2018-01-01

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  13. Incremental diagnostic value of targeted biopsy using mpMRI-TRUS fusion versus 14-fragments prostatic biopsy. A prospective controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Mariotti, Guilherme C.; Falsarella, Priscila M.; Garcia, Rodrigo G.; Queiroz, Marcos R.G. [Hospital Israelita Albert Einstein, Department of Interventional Radiology, Sao Paulo (Brazil); Lemos, Gustavo C. [Hospital Israelita Albert Einstein, Department of Urology, Sao Paulo (Brazil); Baroni, Ronaldo H. [Hospital Israelita Albert Einstein, Department of Radiology, Sao Paulo (Brazil)

    2018-01-15

    To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. (orig.)

  14. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  15. How Do We Write about Performance in Serial Television?

    Directory of Open Access Journals (Sweden)

    Elliott Logan

    2015-05-01

    Full Text Available Television studies has produced few sustained analyses of performance in serial television. Yet film studies scholarship has shown how attending to the integration of performances with other aspects of film style is crucial to the interpretation and appreciation of expression and meaning in filmed narrative fictions. However, as a particle form of filmed serial narrative, series television raises a number of questions about performance that will not necessarily be satisfyingly addressed by the direct adoption and application of approaches to writing about performance that have been honed in regard to film. How, then, do we write about performance in television serials in ways that recognise and accommodate the form’s relationship to film, while at the same time appropriately acknowledging and responding to long-form television’s serial status? To examine the difficulties and opportunities of approaching performance in serial television this way, the article conducts close readings of various pieces of television studies writing on performance, by scholars such as Jason Mittell, Sue Turnbull, George Toles, and Steven Peacock. Their work brings into view film and television’s points of common relation, and the distinctive challenges, achievements, and rewards of appreciating the best television serials, and the performances in them.

  16. Determination of motive of serial invaders as a stage of serial murders investigation

    Directory of Open Access Journals (Sweden)

    Davydov A.B.

    2017-04-01

    Full Text Available the article discusses the existing classification of motives of serial murderers. The author provides the classification, which is based on the technique of extreme meanings offered by D.A. Leontyev.

  17. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  18. Playing at Serial Acquisitions

    NARCIS (Netherlands)

    J.T.J. Smit (Han); T. Moraitis (Thras)

    2010-01-01

    textabstractBehavioral biases can result in suboptimal acquisition decisions-with the potential for errors exacerbated in consolidating industries, where consolidators design serial acquisition strategies and fight escalating takeover battles for platform companies that may determine their future

  19. PORNOGRAFI DALAM SERIAL ANIME ANAK (ANALISIS SEMIOTIKA DALAM SERIAL CRAYON SHIN CHAN

    Directory of Open Access Journals (Sweden)

    - Sangidun

    2017-01-01

    Full Text Available Crayon Shin Chan, a Japanese two-dimension animation series broadcast in one of private Indonesian TVs, is categorized into child’s program since it is broadcast at child’s prime time, Sunday 08.30 a.m. In spite of its broadcast time, this series consist of symbols directed not for children, such as some acts that are not appropriate to be done by children, especially in Indonesia. Moreover, adult symbols of sex are also found in the program. For this reason it will be interesting to analyze it using semiotic analysis. Semiotics is the study of symbol and its meaning which its principle concept is that both signifier and signified consist of symbols and are related to denotation and connotation.   Crayon Shin Chan merupakan serial animasi dua dimensi yang tayang di salah satu stasiun televisi swasta di Indonesia. Ini merupakan produk animasi 2 dimensi yang diimpor dari Jepang. Di Indonesia, serial ini masuk dalam kategori acara anak. Hal ini dapat dilihat dari jam penayangannya yang merupakan waktu prime time bagi anak, yakni pada hari minggu pukul 08.30. Akan tetapi, pada serial ini banyak simbol-simbol yang mengarah pada tayangan yang bukan untuk anak-anak, yakni adeganadegan yang tidak pantas dilakukan oleh anak khususnya di Indonesia. Serta adanya pula simbol-simbol yang mengarah pada tayangan berbau dewasa. Tentu akan menarik jika tayangan ini diteliti menggunakan analisis semiotika. Semiotika sendiri merupakan kajian ilmu mengenai tanda dan makna. Yang pada prinsipnya, konsep penting seperti penanda (signifier dan petanda (signified sama-sama terdiri dari tanda dan terkait dengan denotasi dan konotasi.

  20. Stochastic modeling of a serial killer.

    Science.gov (United States)

    Simkin, M V; Roychowdhury, V P

    2014-08-21

    We analyze the time pattern of the activity of a serial killer, who during 12 years had murdered 53 people. The plot of the cumulative number of murders as a function of time is of "Devil's staircase" type. The distribution of the intervals between murders (step length) follows a power law with the exponent of 1.4. We propose a model according to which the serial killer commits murders when neuronal excitation in his brain exceeds certain threshold. We model this neural activity as a branching process, which in turn is approximated by a random walk. As the distribution of the random walk return times is a power law with the exponent 1.5, the distribution of the inter-murder intervals is thus explained. We illustrate analytical results by numerical simulation. Time pattern activity data from two other serial killers further substantiate our analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. An Investigation of Selective College and University Libraries' Serial Arrangement.

    Science.gov (United States)

    Kesler, Elizabeth Gates; Teborek, Gay

    Data from a survey on serials arrangement procedures and policies at academic libraries was used by the University of Rhode Island (URI) Library in changing current serials policies. Ten libraries, four of which have similar serial holdings and user populations to URI, responded to a questionnaire. Information was obtained on classification versus…

  2. Serials cataloging at the turn of the century

    CERN Document Server

    Williams, James W

    2014-01-01

    An overview of the research topics and trends that have appeared over the last five years, Serials Cataloging at the Turn of the Century doesn't just tell you that there has been a lot of change--that the information environment is something of a chameleon, always beguiling and slipping out of grasp. Instead, it gives you the plain facts on the specific challenges serials catalogers have been facing and how they're meeting adversity head-on, ready to gain the advantage in the rumble with proliferating information and formats.Comprehensive, resource-packed, and easy-to-digest, Serials Catalogin

  3. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  4. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  5. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  6. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  7. Fast Grasp Contact Computation for a Serial Robot

    Science.gov (United States)

    Shi, Jianying (Inventor); Hargrave, Brian (Inventor); Diftler, Myron A. (Inventor)

    2015-01-01

    A system includes a controller and a serial robot having links that are interconnected by a joint, wherein the robot can grasp a three-dimensional (3D) object in response to a commanded grasp pose. The controller receives input information, including the commanded grasp pose, a first set of information describing the kinematics of the robot, and a second set of information describing the position of the object to be grasped. The controller also calculates, in a two-dimensional (2D) plane, a set of contact points between the serial robot and a surface of the 3D object needed for the serial robot to achieve the commanded grasp pose. A required joint angle is then calculated in the 2D plane between the pair of links using the set of contact points. A control action is then executed with respect to the motion of the serial robot using the required joint angle.

  8. Representation of the serial killer on the Italian Internet.

    Science.gov (United States)

    Villano, P; Bastianoni, P; Melotti, G

    2001-10-01

    The representation of serial killers was examined from the analysis of 317 Web pages in the Italian language to study how the psychological profiles of serial killers are described on the Italian Internet. The correspondence analysis of the content of these Web pages shows that in Italy the serial killer is associated with words such as "monster" and "horror," which suggest and imply psychological perversion and aberrant acts. These traits are peculiar for the Italian scenario.

  9. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  10. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Effects of Serial Rehearsal Training on Memory Search

    Science.gov (United States)

    McCauley, Charley; And Others

    1976-01-01

    Half the subjects were trained to use a serial rehearsal strategy during target set storage and half were given no strategy training. The results indicate that the rate of memory search is IQ-related, and that serial rehearsal training facilitates memory search when rehearsal is covert. (Author/BW)

  12. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  13. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  14. Highlights in radiation measuring technique's - Serial Micro Channel SMC 2100

    International Nuclear Information System (INIS)

    Kandler, M.; Hoffmann, Ch.

    2002-01-01

    The Serial Micro Channel SMC 2100 offers an ''intelligent stand alone'' electronics for the radiation measuring technique's. First it is designed of being connected to a serial interface RS232 of a PC. With a RS485 serial interface on a PC, a network structure can be generated. It has all functional modules which are necessary for the measurement of detector signals. Hence it is possible to directly connect any detector for radiation measurement to a PC, laptop, or notebook. All variations can be operated without PC support too. It has a modular structure and consists of two blocks, the functional modules and the basic modules. The Serial Micro Channel SMC 2100 may be directly coupled to a detector, which therefore makes the realisation of an ''intelligent radiation detector'' with serial link RS232 or RS485. (orig.)

  15. Examining the relationship between free recall and immediate serial recall: the serial nature of recall and the effect of test expectancy.

    Science.gov (United States)

    Bhatarah, Parveen; Ward, Geoff; Tan, Lydia

    2008-01-01

    In two experiments, we examined the relationship between free recall and immediate serial recall (ISR), using a within-subjects (Experiment 1) and a between-subjects (Experiment 2) design. In both experiments, participants read aloud lists of eight words and were precued or postcued to respond using free recall or ISR. The serial position curves were U-shaped for free recall and showed extended primacy effects with little or no recency for ISR, and there was little or no difference between recall for the precued and the postcued conditions. Critically, analyses of the output order showed that although the participants started their recall from different list positions in the two tasks, the degree to which subsequent recall was serial in a forward order was strikingly similar. We argue that recalling in a serial forward order is a general characteristic of memory and that performance on ISR and free recall is underpinned by common memory mechanisms.

  16. Multistage parallel-serial time averaging filters

    International Nuclear Information System (INIS)

    Theodosiou, G.E.

    1980-01-01

    Here, a new time averaging circuit design, the 'parallel filter' is presented, which can reduce the time jitter, introduced in time measurements using counters of large dimensions. This parallel filter could be considered as a single stage unit circuit which can be repeated an arbitrary number of times in series, thus providing a parallel-serial filter type as a result. The main advantages of such a filter over a serial one are much less electronic gate jitter and time delay for the same amount of total time uncertainty reduction. (orig.)

  17. Converting serial networks to Ethernet communications

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Elroy [Freewave Technologies, Inc., Boulder, CO (United States). Latin America

    2008-07-01

    Many oil and gas producers and pipeline companies find themselves in an awkward position. They have invested millions of dollars in legacy serial communications systems and in most cases, millions more in older SCADA remote terminal units and electronic flow meters. There is a desire throughout most of the industry to convert these systems to Ethernet. This presentation will explore how Ethernet protocol offers advantages over the older serial communications in terms of peer to peer communication, faster polling cycles, and the ability to poll multiple devices at the same time. (author)

  18. Implementation of Serial and Parallel Bubble Sort on Fpga

    OpenAIRE

    Purnomo, Dwi Marhaendro Jati; Arinaldi, Ahmad; Priyantini, Dwi Teguh; Wibisono, Ari; Febrian, Andreas

    2016-01-01

    Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort r...

  19. Serial forced displacement in American cities, 1916-2010.

    Science.gov (United States)

    Fullilove, Mindy Thompson; Wallace, Rodrick

    2011-06-01

    Serial forced displacement has been defined as the repetitive, coercive upheaval of groups. In this essay, we examine the history of serial forced displacement in American cities due to federal, state, and local government policies. We propose that serial forced displacement sets up a dynamic process that includes an increase in interpersonal and structural violence, an inability to react in a timely fashion to patterns of threat or opportunity, and a cycle of fragmentation as a result of the first two. We present the history of the policies as they affected one urban neighborhood, Pittsburgh's Hill District. We conclude by examining ways in which this problematic process might be addressed.

  20. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  1. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  2. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  3. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  4. Kinematics and dynamics analysis of a novel serial-parallel dynamic simulator

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Bo; Zhang, Lian Dong; Yu, Jingjing [Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, Qinhuangdao, Hebei (China)

    2016-11-15

    A serial-parallel dynamics simulator based on serial-parallel manipulator is proposed. According to the dynamics simulator motion requirement, the proposed serial-parallel dynamics simulator formed by 3-RRS (active revolute joint-revolute joint-spherical joint) and 3-SPR (Spherical joint-active prismatic joint-revolute joint) PMs adopts the outer and inner layout. By integrating the kinematics, constraint and coupling information of the 3-RRS and 3-SPR PMs into the serial-parallel manipulator, the inverse Jacobian matrix, velocity, and acceleration of the serial-parallel dynamics simulator are studied. Based on the principle of virtual work and the kinematics model, the inverse dynamic model is established. Finally, the workspace of the (3-RRS)+(3-SPR) dynamics simulator is constructed.

  5. Kinematics and dynamics analysis of a novel serial-parallel dynamic simulator

    International Nuclear Information System (INIS)

    Hu, Bo; Zhang, Lian Dong; Yu, Jingjing

    2016-01-01

    A serial-parallel dynamics simulator based on serial-parallel manipulator is proposed. According to the dynamics simulator motion requirement, the proposed serial-parallel dynamics simulator formed by 3-RRS (active revolute joint-revolute joint-spherical joint) and 3-SPR (Spherical joint-active prismatic joint-revolute joint) PMs adopts the outer and inner layout. By integrating the kinematics, constraint and coupling information of the 3-RRS and 3-SPR PMs into the serial-parallel manipulator, the inverse Jacobian matrix, velocity, and acceleration of the serial-parallel dynamics simulator are studied. Based on the principle of virtual work and the kinematics model, the inverse dynamic model is established. Finally, the workspace of the (3-RRS)+(3-SPR) dynamics simulator is constructed

  6. Recommendations for CAMAC Serial Highway drivers and LAM Graders for the SCC-L2 Serial Crate Controller

    International Nuclear Information System (INIS)

    1978-01-01

    The functional requirements of Drivers for the CAMAC Serial Highway defined in IEEE Standard 595-1976 are described. The description is independent of the implementation, and in particular no assumption is made about the boundary between hardware and software within the Driver. Topics covered are the user interface, the supporting system services required, demand handling, and a detailed discussion of the message analysis for various levels of error recovery. An appendix describes the recommended features of LAM Graders for use with the Serial Crate Controller Type L2 of IEEE Std 595-1976

  7. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  8. A psychological profile of a serial killer: a case report.

    Science.gov (United States)

    Dogra, T D; Leenaars, Antoon A; Chadha, R K; Manju, Mehta; Lalwani, Sanjeev; Sood, Mamta; Lester, David; Raina, Anupuma; Behera, C

    2012-01-01

    Serial killers have always fascinated society. A serial killer is typically defined as a perpetrator who murders three or more people over a period of time. Most reported cases of serial killers come from the United States and Canada. In India, there are few reported cases. We present, to the best of our knowledge, the first Indian case in the literature. The present case is of a 28-year-old man, Surinder Koli. The Department of Forensic Medicine & Toxicology, All India Institute of Medical Sciences, New Delphi handled the forensic study. We present a most unique psychological investigation into the mind of a serial killer.

  9. Malignant sex and aggression: an overview of serial sexual homicide.

    Science.gov (United States)

    Myers, W C; Reccoppa, L; Burton, K; McElroy, R

    1993-01-01

    Serial murderers have attracted considerable attention in the popular press and criminal justice field, but scientific literature about these individuals is limited. This article provides an overview, from a psychiatric perspective, of serial sexual homicide, one type of serial killing. Characteristics of this type of murder and of these offenders are discussed. Defining qualities and diagnoses applicable to serial sexual killers are reviewed. Various etiologic theories are discussed, with emphasis on the role of fantasy and psychodynamic explanations. Governmental agencies involved in combating this type of crime, along with the role of mental health professionals in criminal profiling, are presented. Finally, the authors explore the reaction of society to this phenomenon.

  10. Transtornos de personalidade, psicopatia e serial killers Personality disorders, psychopathy and serial killers

    Directory of Open Access Journals (Sweden)

    Hilda C P Morana

    2006-10-01

    Full Text Available OBJETIVO: Apresentar as características básicas dos diversos transtornos específicos de personalidade, mas centrando-se no transtorno de personalidade anti-social, fazendo sua diferenciação com psicopatia. O estudo ainda se propõe a abordar a figura do serial killer, apontando a presença de aspectos psicopáticos no homicídio seriado. MÉTODO: Uma revisão bibliográfica foi feita no sentido de se abordar convergências e divergências entre diversos autores sobre um assunto tão polêmico, sobretudo quanto à viabilidade de tratamento dessa clientela forense. RESULTADOS: Enquanto o transtorno de personalidade anti-social é um diagnóstico médico, pode-se entender o termo "psicopatia", pertencente à esfera psiquiátrico-forense, como um "diagnóstico legal". Não se pode falar ainda de tratamento eficaz para os chamados "serial killers". CONCLUSÃO: Os transtornos de personalidade, especialmente o tipo anti-social, representam ainda hoje um verdadeiro desafio para a psiquiatria forense. O local mais adequado e justo para seus portadores, bem como recomendação homogênea e padronizada de tratamento são questões ainda não respondidas.OBJECTIVE: To illustrate the basic characteristics of several specific personality disorders, focusing mainly in antisocial personality disorder. The differences between antisocial personality disorder and psychopathy are highlighted. Serial killers and its psychopathic aspects are also discussed. METHOD: A bibliographic review was completed in order to outline convergences and divergences among different authors about this controversial issue, especially those concerning the possibility of treatment. RESULTS: While anti-social personality disorder is a medical diagnosis, the term "psychopathy" (which belongs to the sphere of forensic psychiatry may be understood as a "legal diagnosis". It is not still possible to identify an effective treatment for serial killers. CONCLUSION: Personality disorders

  11. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  12. Selection and Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Chen, Jing

    2011-01-01

    Although it has been broadly evidenced that entrepreneurial experience plays a substantial role in the emergence of serial entrepreneurship, the debate is still going on about whether this relationship should be attributed to learning by doing or instead be explained by selection on ability. This...

  13. Suicide in serial killers.

    Science.gov (United States)

    Lester, David; White, John

    2010-02-01

    In a sample of 248 killers of two victims in America from 1900 to 2005, obtained from an encyclopedia of serial killers by Newton (2006), those completing suicide did not differ in sex, race, or the motive for the killing from those who were arrested.

  14. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  15. Optimal combinations for detection of prostate cancer: systematic sextant and laterally directed biopsies versus systematic sextant and color Doppler-targeted biopsies.

    Science.gov (United States)

    Kravchick, Sergey; Cytron, Shmuel; Peled, Ronit; London, Daniel; Sibi, Yosef; Ben-Dor, David

    2004-02-01

    To determine the accuracy of different combinations of biopsies in detecting prostate cancer. The standard sextant protocol for obtaining prostate biopsy underestimates the presence of prostate cancer. Conversely, an increased cancer detection rate has been obtained with additional laterally directed biopsies. The results of the studies dedicated to transrectal color Doppler (CD) sonography have shown that it might detect neoplastic lesions with no corresponding gray-scale abnormality. A total of 120 consecutive patients underwent sextant biopsy with additional biopsy cores taken from the lateral peripheral zone (four to six cores, depending on the prostate volume) and CD-guided biopsy. The sensitivity of laterally directed, CD-guided, and different combinations of biopsies was compared. Various patient, clinical, and pathologic factors were compared, and multivariate analysis was performed to assess the strongest predictor of cancer detection. Cancer was detected in 43 (35.8%) of 120 patients. The combination of sextant biopsy with laterally directed cores gained sensitivity to 56.6% compared with 67.4% obtained in the regimen that combined sextant and CD-guided biopsy. The CD regimen detected cancer in 11 additional patients. However, the differences in the detection rates of these combinations were not statistically significant (P = 0.797). The results of multivariate analysis showed that sextant biopsy and laterally directed cores were the strongest predictors of cancer detection (odds ratio 8.356 versus 49.282; 95% confidence interval 1.698 to 41.114 versus 10.508 to 231.130). The regimen that included sextant and CD-guided biopsy was the most sensitive. However, only standard sextant and laterally directed biopsies were statistically significant predictors of cancer detection on biopsy.

  16. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  17. The serial message-passing schedule for LDPC decoding algorithms

    Science.gov (United States)

    Liu, Mingshan; Liu, Shanshan; Zhou, Yuan; Jiang, Xue

    2015-12-01

    The conventional message-passing schedule for LDPC decoding algorithms is the so-called flooding schedule. It has the disadvantage that the updated messages cannot be used until next iteration, thus reducing the convergence speed . In this case, the Layered Decoding algorithm (LBP) based on serial message-passing schedule is proposed. In this paper the decoding principle of LBP algorithm is briefly introduced, and then proposed its two improved algorithms, the grouped serial decoding algorithm (Grouped LBP) and the semi-serial decoding algorithm .They can improve LBP algorithm's decoding speed while maintaining a good decoding performance.

  18. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  19. Nanoflow electrospinning serial femtosecond crystallography

    International Nuclear Information System (INIS)

    Sierra, Raymond G.; Laksmono, Hartawan; Kern, Jan; Tran, Rosalie; Hattne, Johan; Alonso-Mori, Roberto; Lassalle-Kaiser, Benedikt; Glöckner, Carina; Hellmich, Julia; Schafer, Donald W.; Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W.; Sellberg, Jonas; McQueen, Trevor A.; Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien; Zwart, Petrus H.; Glatzel, Pieter; Milathianaki, Despina; White, William E.; Adams, Paul D.; Williams, Garth J.; Boutet, Sébastien; Zouni, Athina; Messinger, Johannes; Sauter, Nicholas K.; Bergmann, Uwe; Yano, Junko; Yachandra, Vittal K.; Bogan, Michael J.

    2012-01-01

    A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min −1 to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min −1 and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption

  20. Nanoflow electrospinning serial femtosecond crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, Raymond G.; Laksmono, Hartawan [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Kern, Jan [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Tran, Rosalie; Hattne, Johan [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Alonso-Mori, Roberto [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Lassalle-Kaiser, Benedikt [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glöckner, Carina; Hellmich, Julia [Technische Universität Berlin, Strasse des 17 Juni 135, 10623 Berlin (Germany); Schafer, Donald W. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Sellberg, Jonas [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Stockholm University, S-106 91 Stockholm (Sweden); McQueen, Trevor A. [Stanford University, Stanford, CA 94025 (United States); Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Zwart, Petrus H. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glatzel, Pieter [European Synchrotron Radiation Facility, Grenoble (France); Milathianaki, Despina; White, William E. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Adams, Paul D. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Williams, Garth J.; Boutet, Sébastien [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Zouni, Athina [Technische Universität Berlin, Strasse des 17 Juni 135, 10623 Berlin (Germany); Messinger, Johannes [Umeå Universitet, Umeå (Sweden); Sauter, Nicholas K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bergmann, Uwe [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Yano, Junko; Yachandra, Vittal K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bogan, Michael J., E-mail: mbogan@slac.stanford.edu [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-11-01

    A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min{sup −1} to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min{sup −1} and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.

  1. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  2. Automated gun biopsy of the prostate under ultrasound guide

    International Nuclear Information System (INIS)

    Yang, Ik; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho; Lim, Joo Won

    1994-01-01

    To assess the effectiveness and clinical usefulness of prostate biopsy by automated gun biopsy device under the transrectal ultrasonographic guidance, authors analysed the result of biopsy and the patients status after biopsy procedure. The subjects consisted of 24 patients with prostatic disease. Biopsy instrument was an automated gun biopsy device loaded with an 18 gauze biopsy needle. All the patients were admitted to the hospital. No analgesics was given. All the procedure was performed with the patient in left lateral decubitus. Biopsy was performed at 2-4 different points of the prostate in 22 cases, but recently, six different points were targeted in two patients. Biopsy specimens were sufficient in 21 cases but insufficient in three cases. Histologic examination of biopsy specimens showed that 13 cases were nodular hyperplasia, eight cases were cancerous and three cases were inflammation. There was no clinically significant complication. There was mild to moderate degree of pain in all patients. Tansrectal biopsy of the prostate with an automated gun biopsy device under ultrasonographic guidance is considered relatively easy, handy and useful procedure in patients with prostatic disease. The procedure may be performed on the out patient basis

  3. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  4. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  5. Three more semantic serial position functions and a SIMPLE explanation.

    Science.gov (United States)

    Kelley, Matthew R; Neath, Ian; Surprenant, Aimée M

    2013-05-01

    There are innumerable demonstrations of serial position functions-with characteristic primacy and recency effects-in episodic tasks, but there are only a handful of such demonstrations in semantic memory tasks, and those demonstrations have used only two types of stimuli. Here, we provide three more examples of serial position functions when recalling from semantic memory. Participants were asked to reconstruct the order of (1) two cartoon theme song lyrics, (2) the seven Harry Potter books, and (3) two sets of movies, and all three demonstrations yielded conventional-looking serial position functions with primacy and recency effects. The data were well-fit by SIMPLE, a local distinctiveness model of memory that was originally designed to account for serial position effects in short- and long-term episodic memory. According to SIMPLE, serial position functions in both episodic and semantic memory tasks arise from the same type of processing: Items that are more separated from their close neighbors in psychological space at the time of recall will be better remembered. We argue that currently available evidence suggests that serial position functions observed when recalling items that are presumably in semantic memory arise because of the same processes as those observed when recalling items that are presumably in episodic memory.

  6. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  7. Natural born killers?: the development of the sexually sadistic serial killer.

    Science.gov (United States)

    Johnson, B R; Becker, J V

    1997-01-01

    Today's society seems enthralled with serial killers in the news and the media. Forensic psychiatrists often interview serial killers after they have been caught. There are retrospective studies and case reports of individuals who have committed sexually sadistic serial murders. However, there exists a dearth of case reports on adolescents who have expressed serious fantasies about becoming serial killer prior to actualizing their fantasy. This article presents nine clinical cases of 14- to 18-year-olds who have clinically significant fantasies of becoming a serial killer. Similarities exist in these adolescent cases when compared with retrospective studies and case reports of serial killers on the role of sexually sadistic fantasies and actual killings. Since it has been established that sexual paraphilias may develop at a young age, one can surmise that sadistic paraphilias may also develop in some adolescents. The question is posed, can we predict which of these adolescents may go on to actually become serial killers? This article focuses on how the sexually sadistic fantasy can eventually be acted out and possible motives for the act to be repeated multiple times. Finally, recommendations are made about assessing and treating a youngster who expresses violent sexually sadistic killing fantasies so that attempts can be made to interrupt the progression to actual killing.

  8. Using Serial and Discrete Digit Naming to Unravel Word Reading Processes.

    Science.gov (United States)

    Altani, Angeliki; Protopapas, Athanassios; Georgiou, George K

    2018-01-01

    During reading acquisition, word recognition is assumed to undergo a developmental shift from slow serial/sublexical processing of letter strings to fast parallel processing of whole word forms. This shift has been proposed to be detected by examining the size of the relationship between serial- and discrete-trial versions of word reading and rapid naming tasks. Specifically, a strong association between serial naming of symbols and single word reading suggests that words are processed serially, whereas a strong association between discrete naming of symbols and single word reading suggests that words are processed in parallel as wholes. In this study, 429 Grade 1, 3, and 5 English-speaking Canadian children were tested on serial and discrete digit naming and word reading. Across grades, single word reading was more strongly associated with discrete naming than with serial naming of digits, indicating that short high-frequency words are processed as whole units early in the development of reading ability in English. In contrast, serial naming was not a unique predictor of single word reading across grades, suggesting that within-word sequential processing was not required for the successful recognition for this set of words. Factor mixture analysis revealed that our participants could be clustered into two classes, namely beginning and more advanced readers. Serial naming uniquely predicted single word reading only among the first class of readers, indicating that novice readers rely on a serial strategy to decode words. Yet, a considerable proportion of Grade 1 students were assigned to the second class, evidently being able to process short high-frequency words as unitized symbols. We consider these findings together with those from previous studies to challenge the hypothesis of a binary distinction between serial/sublexical and parallel/lexical processing in word reading. We argue instead that sequential processing in word reading operates on a continuum

  9. The Organized/Disorganized Typology of Serial Murder: Myth or Model?

    OpenAIRE

    Canter, David V.; Alison, Laurence J.; Alison, Emily; Wentink, Natalia

    2004-01-01

    Despite weaknesses in the organized/disorganized classification of serial killers, it is drawn on for "offender profiles," theories of offending, and in murder trials. This dichotomy was therefore tested by the multidimensional scaling of the co-occurrence of 39 aspects of serial killings derived 100 murders committed by 100 U.S. serial killers. Results revealed no distinct subsets of offense characteristics reflecting the dichotomy. They showed a subset of organized features typical of most ...

  10. [When to ask for a skin biopsy in a patient with leg ulcer? Retrospective study of 143 consecutive biopsies].

    Science.gov (United States)

    Stansal, A; Khayat, K; Duchatelle, V; Tella, E; Gautier, V; Sfeir, D; Attal, R; Lazareth, I; Priollet, P

    2018-02-01

    A vascular cause is found in around 85% of leg ulcer patients, but non-vascular causes are also observed. Their diagnosis is based on a set of clinical arguments and skin biopsy with histological analysis. The aim of this study was to analyze the results of these biopsies and to find common criteria for ulcers whose skin biopsies had led to the diagnosis of a non-vascular ulcer. A retrospective study was carried out on the analysis of 143 skin biopsies of leg ulcers. The reasons for the biopsy were mainly atypical clinical signs and/or the lack of improvement in care after 6 months, as advocated by the French health authorities. The skin biopsies led to a diagnosis of non-vascular ulcer in 4.9% of cases (7/143), including skin cancer (n=5, 3.5%), cutaneous leishmaniasis (n=1, 0.7%) and Pyoderma gangrenosum (n=1, 0.7%). The univariate statistical analysis revealed that an elevated rim and abnormal excessive granulation tissue were significantly more frequently found in these ulcers. All patients with a positive skin biopsy had associated vascular involvement. This study found a 5% rate of non-vascular causes of ulcers, mainly skin cancer. Elevated rims and abnormal excessive granulation tissue were the unusual features most commonly found in these ulcers. All patients whose skin biopsy revealed a non-vascular cause had associated vascular involvement. This information confirms the need to perform a skin biopsy, even in the presence of a vascular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  12. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  13. Unguided bronchoscopic biopsy: Does yield increase with operator experience

    Directory of Open Access Journals (Sweden)

    Tyagi Rahul

    2017-08-01

    Full Text Available Background Bronchoscopic Forceps biopsy (Endobronchial Biopsy (EBB and Trans Bronchial Lung Biopsy (TBLB are commonly performed for diagnosis in patients with endobronchial abnormalities or diffuse parenchymal involvement. As the operator gains experience his yield of various diagnostic bronchoscopic biopsies is expected to increase, however, no studies on the subject are available in literature. Aims To determine the effect of on- job experience on the yield of unguided bronchoscopic biopsies. Methods A total of 244 bronchoscopies were performed between Oct 2013 and Oct 2016. A retrospective analysis of all these bronchoscopies was undertaken. All patients who underwent biopsy were included in the study. Patients were divided into two groups with first group (Group A comprising of biopsies done between Oct 2013 to Apr 2015 and second group comprising biopsies done between May 2015 to Oct 2016 (Group B. The diagnostic yield in two groups was compared. Results Total 71 bronchoscopic biopsies were performed during Oct 2013 to Oct 2016. 36 patients were included in group A and 35 patients were included in group B. The groups were matched in demographic profile, clinical diagnosis, bronchoscopic findings and type of biopsy undertaken. The biopsy was diagnostic in 31 patient (43.6 per cent and nondiagnostic in 33 patients (46.4 per cent. There were 15 diagnostic biopsies in group A and 16 diagnostic biopsies in group B. The difference in the diagnostic biopsies between the two groups was not significant. Conclusion There was no significant impact of on job experience on diagnostic yield of biopsies. This may be due to adequate exposure during training leading to a diagnostic plateau being reached.

  14. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  15. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  16. Short- and long-term memory contributions to immediate serial recognition: evidence from serial position effects.

    Science.gov (United States)

    Purser, Harry; Jarrold, Christopher

    2010-04-01

    A long-standing body of research supports the existence of separable short- and long-term memory systems, relying on phonological and semantic codes, respectively. The aim of the current study was to measure the contribution of long-term knowledge to short-term memory performance by looking for evidence of phonologically and semantically coded storage within a short-term recognition task, among developmental samples. Each experimental trial presented 4-item lists. In Experiment 1 typically developing children aged 5 to 6 years old showed evidence of phonologically coded storage across all 4 serial positions, but evidence of semantically coded storage at Serial Positions 1 and 2. In a further experiment, a group of individuals with Down syndrome was investigated as a test case that might be expected to use semantic coding to support short-term storage, but these participants showed no evidence of semantically coded storage and evidenced phonologically coded storage only at Serial Position 4, suggesting that individuals with Down syndrome have a verbal short-term memory capacity of 1 item. Our results suggest that previous evidence of semantic effects on "short-term memory performance" does not reflect semantic coding in short-term memory itself, and provide an experimental method for researchers wishing to take a relatively pure measure of verbal short-term memory capacity, in cases where rehearsal is unlikely.

  17. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    OpenAIRE

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-01-01

    Purpose: To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. Methods: We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assist...

  18. Utilization of serial resources in libraries of selected tertiary ...

    African Journals Online (AJOL)

    Information Impact: Journal of Information and Knowledge Management ... security personnel for adequate monitoring of the serial materials, as well as the need for authors and stakeholders in education to donate more serial materials in order to enrich the collections in the library and enhance academic performance.

  19. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  20. Efficacy and Complications of Ultrasound-Guided Percutaneous Renal Biopsy Using Automatic Biopsy Gun in Pediatric Diffuse Renal Disease: Analysis of 97 Cases

    International Nuclear Information System (INIS)

    Han, Seung Min; Chung, Tae Woong; Yoon, Woong

    2007-01-01

    To evaluate the diagnostic efficacy and complications of ultrasound-guided percutaneous renal biopsy using automatic biopsy gun in patients with pediatric diffuse renal disease. Using an 18G automatic biopsy gun, biopsies were performed on 97 pediatric patients with clinically suspicious diffuse renal disease. The acquired tissue specimens were analyzed by photomicroscopy, immunofluorescence, and electron microscopy to support the diagnosis. In the 97 biopsies, the success of the histologic diagnosis, number of glomeruli, and complication rates were retrospectively evaluated by analyzing the variable exams and clinical records. Adequate tissue for histologic diagnosis was obtained in 91 of 97 biopsies (94%) and the mean number of glomeruli was 9.6. Complications such as minute pain, gross hematuria, and small perirenal hematoma presented in 22 of the 97 biopsies (23%), all of which either improved within 5-72 hours or did not need specific treatment. Ultrasound-guided percutaneous renal biopsy using 18G automatic biopsy gun is an effective and safe method for the histologic diagnosis of pediatric diffuse renal disease without any major complication

  1. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  2. Full-thickness rectal biopsy in children suspicious for Hirschsprung's disease is safe and yields a low number of insufficient biopsies

    DEFF Research Database (Denmark)

    Bjørn, Niels; Rasmussen, Lars; Qvist, Niels

    2018-01-01

    INTRODUCTION: The diagnosis of Hirschsprung's disease (HD) relies on the histological demonstration of aganglionosis in the bowel wall. Biopsies may be obtained by rectal suction biopsy (RSB) or by transanal full-thickness excision biopsy (FTB). The objective of the present study was to evaluate...... the frequency of complications and inconclusive biopsies after FTB in children referred with suspicion of HD. The secondary objective was to calculate the frequency of proven aganglionosis. METHODS: A retrospective chart review was performed of all patients under the age of 16years who underwent transanal FTB...... during the time period of 2008-2014. RESULTS: A total of 555 patients were included in the review. Inconclusive biopsies were found at the primary biopsy in 35 patients (5.9%). Aganglionosis was found in 12% of the cases. The complication rate was 6.6% (39 patients), 85% of which were classified...

  3. IT-based Value Creation in Serial Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    serial acquirers realize IT-based value, we integrate and model the findings on individual acquisitions from the extant literature, and extend that model to explain the effects of sequential acquisitions in a growth-by-acquisition strategy. This extended model, drawing on the Resource-Based Theory......The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...

  4. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  5. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  6. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  7. Prostatic biopsy after irradiation therapy for prostatic cancer

    International Nuclear Information System (INIS)

    Scardino, P.T.; Wheeler, T.M.

    1985-01-01

    To determine the prognostic significance of a routine needle biopsy of the prostate performed six to thirty-six months after the completion of definitive radiotherapy, biopsy results were analyzed in 146 patients who had no evidence of disease at the time of biopsy and who received no other therapy before proved recurrence of the tumor. Patients were followed up a mean of 3.9 years after radioactive gold seed implantation and external beam irradiation. The total dose was 8,000 rad. Among 146 patients, 56 (38%) had one or more positive biopsy results within this time interval. The positive biopsy rate correlated with the clinical stage ranging from 17 per cent in Stage B1N to 59 per cent in Stage C1. The risk of developing local recurrence or distant metastases at any given time after irradiation therapy was markedly greater in those patients with a positive biopsy result (p less than 0.0005). Prostatic biopsy is an accurate means of measuring the success of radiotherapy. A positive postirradiation biopsy result carries grave prognostic implications for the patient and indicates that the treatment has failed

  8. Opportunity recognition: delineating the process and motivators for serial entrepreneurs

    Directory of Open Access Journals (Sweden)

    Boris Urban

    2011-04-01

    Full Text Available Opportunity recognition is a fundamental research issue in entrepreneurship which this paper empirically investigates for serial entrepreneurs. Initially key definitions and boundary conditions of opportunity recognition are explored to elucidate the relevant motivators driving serial entrepreneurs. After operationalising the various concepts, data is collected by surveying serial entrepreneurs (n= 77 based on pre-determined selection criteria. Since the study’s objective is to build solid theory on these new phenomena, descriptive analysis on the empirical results is provided. To test the hypotheses inferential statistics employing parametric and non-parametric tests are used. The findings reveal that the opportunity recognition behaviours are manifest among serial entrepreneurs, with few significant differences on how many new, major businesses have been pursued, or whether they can be said to be successes.

  9. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  10. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  11. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  12. Female serial murderers: directions for future research on a hidden population.

    Science.gov (United States)

    Gurian, Elizabeth A

    2011-02-01

    This comprehensive overview on a sample of 65 cases (134 total offenders, including some partnered teams of more than 2 offenders) provides information on female serial murderers who either work in a mixed-sex offending group or alone. These female serial homicide offenders have a distinct set of offender-victim characteristics, including specific victim preferences, methods, and motivations: Partnered serial homicide offenders are more likely to target adult strangers and dispatch them using a combination of methods, whereas solo female serial murderers are most likely to target adult family members and murder them with poison. These patterns have the potential to add to our understanding of the possible similarities and differences of serial homicide cases by building on established offender characteristics. Convictions and sentences for the offenders are included and areas of future research and implications for treatment with this sample are also explored.

  13. IEEE 1394/firewire a low cost, high speed, digital serial bus

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.

    1997-05-01

    Does the world need yet another 1/0 bus standard? If you need fast and cheap serial video communication, then the answer is yes. As technology advances, so too must data transport mechanisms advance. You can`t expect RS-232 to support real-time digital video, and if you can`t afford expensive professional serial video interfaces, (such as Sony`s Serial Digital Interface), Firewire may be a good solution. IEEE 1394, or commonly known as Firewire, is a general purpose serial bus that meets many of the 1/0 needs of today`s video and multimedia developers. For those of you who only read the first paragraph, here`s Firewire in a nutshell: It provides a guaranteed transfer rate of 10OMbps or 20OMbps of digital data (such as video direct from camera to computer), over an inexpensive, non-proprietary serial bus. Here is a list of its features.

  14. Indexing Serialized Fiction: May the Force Be with You.

    Science.gov (United States)

    Barr, Melissa M.

    The adult novel offers indexers an unusual opportunity to create a serialized fiction index. This research paper involved designing and creating a Character Index, Thesaurus, Glossary, and Abstract (with descriptors) for 21 novels based on the "Star Wars" movies. The novels are an unusual example of serialized fiction featuring main…

  15. Stress in Harmonic Serialism

    Science.gov (United States)

    Pruitt, Kathryn Ringler

    2012-01-01

    This dissertation proposes a model of word stress in a derivational version of Optimality Theory (OT) called Harmonic Serialism (HS; Prince and Smolensky 1993/2004, McCarthy 2000, 2006, 2010a). In this model, the metrical structure of a word is derived through a series of optimizations in which the "best" metrical foot is chosen…

  16. Widespread high grade prostatic intraepithelial neoplasia on biopsy predicts the risk of prostate cancer: A 12 months analysis after three consecutive prostate biopsies

    Directory of Open Access Journals (Sweden)

    Cosimo De Nunzio

    2013-06-01

    Full Text Available Purpose: To evaluate the risk of prostate cancer (PCa on a third prostate biopsy in a group of patients with two consecutive diagnoses of high grade intraepithelial neoplasia (HGPIN. Materials and methods: From November 2004 to December 2007, patients referred to our clinic with a PSA ! 4 ng/ml or an abnormal digital rectal examination (DRE were scheduled for trans-rectal ultrasound (TRUS guided 12-core prostate biopsy. Patients with HGPIN underwent a second prostate biopsy, and if the results of such procedure yielded a second diagnosis of HGPIN, we proposed a third 12-core needle biopsy regardless of PSA value. Crude and adjusted logistic regressions were used to assess predictors of PCa on the third biopsy. Results: A total of 650 patients underwent 12 cores transrectal ultrasound prostatic biopsy in the study period. Of 147 (22% men with a diagnosis of HGPIN, 117 underwent a second prostatic biopsy after six months and 43 a third biopsy after other six months. After the third biopsy, 19 patients (34% still showed HGPIN, 15 (35% were diagnosed with PCa and 9 (21% presented with chronic prostatitis. Widespread HGPIN on a second biopsy was significantly associated with PCa on further biopsy (!2 = 4.04, p = 0.04. Moreover, the presence of widespread HGPIN significantly predicted the risk of PCa on crude and adjusted logistic regressions. Conclusions: Widespread HGPIN on second biopsy is associated with the presence of PCa on a third biopsy. Nonetheless, the relationship between HGPIN and PCa remains complex and further studies are needed to confirm our findings.

  17. The relationship between serial sexual murder and autoerotic asphyxiation.

    Science.gov (United States)

    Myers, Wade C; Bukhanovskiy, Alexandr; Justen, Elle; Morton, Robert J; Tilley, John; Adams, Kenneth; Vandagriff, Virgil L; Hazelwood, Robert R

    2008-04-07

    This case series documents and examines the association between autoerotic asphyxiation, sadomasochism, and serial sexual murderers. Autoerotic asphyxiation, along with other paraphilias found in this population, is reviewed. Five cases of serial sexual killers who engaged in autoerotic asphyxiation were identified worldwide: four from the United States and one from Russia. Case reports for each are provided. All (100%) were found to have sexual sadism in addition to autoerotic asphyxiation. Furthermore, two (40%) had bondage fetishism, and two (40%) had transvestic fetishism, consistent with these paraphilias co-occurring in those with autoerotic asphyxiation. Overall the group averaged 4.0 lifetime paraphilias. Some possible relationships were observed between the offenders' paraphilic orientation and their modus operandi, e.g., all of these serial killers strangled victims-suggesting an association between their sadistic and asphyxiative paraphilic interests. The overlap of seemingly polar opposite paraphilias in this sample--sexual sadism and autoerotic asphyxiation--is explored from a historical and clinical perspective. Multiple commonalities shared between these five offenders and serial sexual murderers in general are addressed. A primary limitation of this study is its small sample size and empirical basis; the results may not be generalizable beyond the sample. The findings from this study support the supposition that crime scene behaviors often reflect paraphilic disturbances in those who commit serial sexual homicides.

  18. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  19. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  20. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  1. Testing Cross-Sectional Correlation in Large Panel Data Models with Serial Correlation

    Directory of Open Access Journals (Sweden)

    Badi H. Baltagi

    2016-11-01

    Full Text Available This paper considers the problem of testing cross-sectional correlation in large panel data models with serially-correlated errors. It finds that existing tests for cross-sectional correlation encounter size distortions with serial correlation in the errors. To control the size, this paper proposes a modification of Pesaran’s Cross-sectional Dependence (CD test to account for serial correlation of an unknown form in the error term. We derive the limiting distribution of this test as N , T → ∞ . The test is distribution free and allows for unknown forms of serial correlation in the errors. Monte Carlo simulations show that the test has good size and power for large panels when serial correlation in the errors is present.

  2. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies; Perkutane stereotaktische Biopsie nicht palpabler Mammalaesionen mit dem Advanced Breast Biopsy Instrumentation (ABBI) System: kritische Evaluation der Indikationsstellung

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G. [Basel Univ. (Switzerland). Inst. fuer Diagnostische Radiologie; Oertli, D. [Basel Univ. (Switzerland). Inst. fuer Chirurgie; Torhorst, J. [Basel Univ. (Switzerland). Inst. fuer Pathologie

    2001-03-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [German] Ziel: Perkutane stereotaktische Biopsien mit dem ABBI stellen eine neue Alternative in der Abklaerung nicht palpabler Mammalaesionen dar. Es soll die Indikationsstellung mit und ohne Anwendung des Breast Imaging Reporting and Data System (BI-RADS) analysiert werden. Material und Methoden: Insgesamt wurde bei 62 Patientinnen mit 64 Laesionen eine Biopsie mit dem ABBI System durchgefuehrt. Die primaere Indikation zur ABBI Biopsie wurde von Nicht-Radiologen aufgrund von Mikrokalzifikationen in 53 Faellen und einer unklaren Verdichtung in 11 Faellen gestellt. Zusaetzlich erfolgte eine retrospektive Indikationsstellung der biopsierten

  3. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  4. Serial-order short-term memory predicts vocabulary development: evidence from a longitudinal study.

    Science.gov (United States)

    Leclercq, Anne-Lise; Majerus, Steve

    2010-03-01

    Serial-order short-term memory (STM), as opposed to item STM, has been shown to be very consistently associated with lexical learning abilities in cross-sectional study designs. This study investigated longitudinal predictions between serial-order STM and vocabulary development. Tasks maximizing the temporary retention of either serial-order or item information were administered to kindergarten children aged 4 and 5. At age 4, age 5, and from age 4 to age 5, serial-order STM capacities, but not item STM capacities, were specifically associated with vocabulary development. Moreover, the increase of serial-order STM capacity from age 4 to age 5 predicted the increase of vocabulary knowledge over the same time period. These results support a theoretical position that assumes an important role for serial-order STM capacities in vocabulary acquisition.

  5. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  6. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  7. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    Science.gov (United States)

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  8. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  9. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  10. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...

  11. Diagnostic approach of myocarditis: strike the golden mean.

    Science.gov (United States)

    Hazebroek, M R; Everaerts, K; Heymans, S

    2014-02-01

    Myocarditis is a challenging diagnosis due to the extreme diversity of clinical manifestations. The actual incidence of myocarditis is also difficult to determine as endomyocardial biopsy (EMB), the diagnostic gold standard, is used infrequently. Nevertheless, in up to 30 % of patients with biopsy-proven myocarditis, progression to dilated cardiomyopathy (DCM) can occur and is associated with a poor prognosis. Recent position statements of the European Society of Cardiology (ESC) and the American Heart Association vary widely with regard to indications for performing an EMB in these patients. This makes decision-making, in particular for general practitioners (GPs) and regional hospitals, difficult and unclear. Therefore, we will present a short summary of the ESC Working Group on Myocardial and Pericardial Diseases statement and our suggestions for GPs and regional hospitals for the diagnostic approach in patients with suspected myocarditis.

  12. Antisocial personality disorder, sexual sadism, malignant narcissism, and serial murder.

    Science.gov (United States)

    Geberth, V J; Turco, R N

    1997-01-01

    This paper examines the research on serial murder and its relationship to antisocial personality disorder and sexual sadism. The concept of malignant narcissism is also discussed. Case studies of serial killers are examined regarding the nature of sexual violation and crime scene behavior.

  13. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  14. Hemispatial neglect and serial order in verbal working memory.

    Science.gov (United States)

    Antoine, Sophie; Ranzini, Mariagrazia; van Dijck, Jean-Philippe; Slama, Hichem; Bonato, Mario; Tousch, Ann; Dewulf, Myrtille; Bier, Jean-Christophe; Gevers, Wim

    2018-01-09

    Working memory refers to our ability to actively maintain and process a limited amount of information during a brief period of time. Often, not only the information itself but also its serial order is crucial for good task performance. It was recently proposed that serial order is grounded in spatial cognition. Here, we compared performance of a group of right hemisphere-damaged patients with hemispatial neglect to healthy controls in verbal working memory tasks. Participants memorized sequences of consonants at span level and had to judge whether a target consonant belonged to the memorized sequence (item task) or whether a pair of consonants were presented in the same order as in the memorized sequence (order task). In line with this idea that serial order is grounded in spatial cognition, we found that neglect patients made significantly more errors in the order task than in the item task compared to healthy controls. Furthermore, this deficit seemed functionally related to neglect severity and was more frequently observed following right posterior brain damage. Interestingly, this specific impairment for serial order in verbal working memory was not lateralized. We advance the hypotheses of a potential contribution to the deficit of serial order in neglect patients of either or both (1) reduced spatial working memory capacity that enables to keep track of the spatial codes that provide memorized items with a positional context, (2) a spatial compression of these codes in the intact representational space. © 2018 The British Psychological Society.

  15. Attractive Serial Dependence in the Absence of an Explicit Task.

    Science.gov (United States)

    Fornaciai, Michele; Park, Joonkoo

    2018-03-01

    Attractive serial dependence refers to an adaptive change in the representation of sensory information, whereby a current stimulus appears to be similar to a previous one. The nature of this phenomenon is controversial, however, as serial dependence could arise from biased perceptual representations or from biased traces of working memory representation at a decisional stage. Here, we demonstrated a neural signature of serial dependence in numerosity perception emerging early in the visual processing stream even in the absence of an explicit task. Furthermore, a psychophysical experiment revealed that numerosity perception is biased by a previously presented stimulus in an attractive way, not by repulsive adaptation. These results suggest that serial dependence is a perceptual phenomenon starting from early levels of visual processing and occurring independently from a decision process, which is consistent with the view that these biases smooth out noise from neural signals to establish perceptual continuity.

  16. Using Behavior Sequence Analysis to Map Serial Killers' Life Histories.

    Science.gov (United States)

    Keatley, David A; Golightly, Hayley; Shephard, Rebecca; Yaksic, Enzo; Reid, Sasha

    2018-03-01

    The aim of the current research was to provide a novel method for mapping the developmental sequences of serial killers' life histories. An in-depth biographical account of serial killers' lives, from birth through to conviction, was gained and analyzed using Behavior Sequence Analysis. The analyses highlight similarities in behavioral events across the serial killers' lives, indicating not only which risk factors occur, but the temporal order of these factors. Results focused on early childhood environment, indicating the role of parental abuse; behaviors and events surrounding criminal histories of serial killers, showing that many had previous convictions and were known to police for other crimes; behaviors surrounding their murders, highlighting differences in victim choice and modus operandi; and, finally, trial pleas and convictions. The present research, therefore, provides a novel approach to synthesizing large volumes of data on criminals and presenting results in accessible, understandable outcomes.

  17. Serial murder by healthcare professionals.

    Science.gov (United States)

    Yorker, Beatrice Crofts; Kizer, Kenneth W; Lampe, Paula; Forrest, A R W; Lannan, Jacquetta M; Russell, Donna A

    2008-01-01

    The prosecution of Charles Cullen, a nurse who killed at least 40 patients over a 16-year period, highlights the need to better understand the phenomenon of serial murder by healthcare professionals. The authors conducted a LexisNexis search which yielded 90 criminal prosecutions of healthcare providers that met inclusion criteria for serial murder of patients. In addition we reviewed epidemiologic studies, toxicology evidence, and court transcripts, to provide data on healthcare professionals who have been prosecuted between 1970 and 2006. Fifty-four of the 90 have been convicted; 45 for serial murder, four for attempted murder, and five pled guilty to lesser charges. Twenty-four more have been indicted and are either awaiting trial or the outcome has not been published. The other 12 prosecutions had a variety of legal outcomes. Injection was the main method used by healthcare killers followed by suffocation, poisoning, and tampering with equipment. Prosecutions were reported from 20 countries with 40% taking place in the United States. Nursing personnel comprised 86% of the healthcare providers prosecuted; physicians 12%, and 2% were allied health professionals. The number of patient deaths that resulted in a murder conviction is 317 and the number of suspicious patient deaths attributed to the 54 convicted caregivers is 2113. These numbers are disturbing and demand that systemic changes in tracking adverse patient incidents associated with presence of a specific healthcare provider be implemented. Hiring practices must shift away from preventing wrongful discharge or denial of employment lawsuits to protecting patients from employees who kill.

  18. Unusual echocardiographic features seen in a case of giant cell myocarditis.

    Science.gov (United States)

    Kochar, Minisha; López-Candales, Angel; Ramani, Gautam; Rajagopalan, Navin; Edelman, Kathy

    2008-11-01

    The case of an 18-year-old college football player with a recent history of streptococcal pharyngitis who was experiencing progressive disabling dyspnea on exertion with easy fatigability and lack of stamina, and was taken to the hospital after a syncopal episode is described. The patient was initially diagnosed with heart failure and treated accordingly. However, because of a fulminant clinical deterioration, an endomyocardial biopsy was recommended, which showed focal giant cell transformation consistent with giant cell myocarditis. Treatment with methylprednisolone and cyclosporine was promptly initiated. Several apical clots were noted during treatment, but the patient attained full recovery with treatment.

  19. Outpatient percutaneous renal biopsy in adult patients

    International Nuclear Information System (INIS)

    Al-Hweish, Abdulla K.; Abdul-Rehman, I. Saeed

    2007-01-01

    To study the safety and efficacy of performing percutanaeous renal biopsy in the outpatient department compared to the traditional inpatient policy, we studied 44 consecutive patients with proteinuria and other urinary sediment abnormalities, at King Fahd Hospital of the University, Al-Khobar, Saudi Arabia, during the period from September 2004 to August 2006. The patients were divided into two groups: group I, in whom kidney biopsy was performed and followed by 1-day hospital admission; and group II, in whom renal biopsy was performed in the outpatient department and followed by 6 hours observation period and then by regular outpatient visits. All biopsies were performed with the use of real-time ultrasound and automated biopsy needle. Patients with a history of bleeding diathesis or abnormal coagulation profile and those receiving warfarin, heparin, aspirin or nonsteroidal anti-inflammatory drugs were excluded from the study. Only minor biopsy-related complications such as gross hematuria, perinephric hematoma that resolved without the need for blood transfusion or surgical intervention occurred in three (13.6%) patients in group I and in two (9.1%) patients in group II. The complications were apparent within 6 hours in all but one patient (97.7%). Overall, hematuria was identified in 52% of patients at <-72 hours, 85% at <-4 hours and 97.7% at <- 6 hours. The 24-hour hematocrit levels were not significantly different between the study groups. One (4.5%) patient from group II had a small perinephric hematoma, which was detected by ultrasound examination at 24 hours but not at 6 hours post biopsy period; it resolved spontaneously without intervention. We conclude that in selected patients, same day discharge after 6 hours of renal biopsy may be given safety without increased risk of complications. (author)

  20. Selection and Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Chen, Jing

    2013-01-01

    There is substantial evidence that serial entrepreneurs outperform de novo entrepreneurs. But is this positive association between prior experience and performance the result of learning by doing or of selection on ability? This paper proposes a strategy that combines the fixed-effects model and IV...... when the analysis focuses on founding new startups in sectors closely related to entrepreneurs' previous ventures....

  1. Serial position effects in mild cognitive impairment.

    Science.gov (United States)

    Howieson, Diane B; Mattek, Nora; Seeyle, Adriana M; Dodge, Hiroko H; Wasserman, Dara; Zitzelberger, Tracy; Jeffrey, Kaye

    2011-03-01

    Mild cognitive impairment (MCI) is often associated with the preclinical phase of Alzheimer's disease (AD). Special scoring of word-list recall data for serial position has been suggested to improve discrimination of normal aging from dementia. We examined serial position effects in word-list recall for MCI participants compared to Alzheimer patients and controls. Individuals with MCI, like Alzheimer patients, had a diminished primacy effect in recalling words from a list. No alternative scoring system was better than standard scoring of word-list recall in distinguishing MCI patients from controls. Retention weighted scoring improved the discrimination of MCI and AD groups.

  2. A combination strategy for tracking the serial criminal

    Science.gov (United States)

    He, Chuan; Zhang, Yuan-Biao; Wan, Jiadi; Yu, Wenjing

    2010-08-01

    We build a Geographic Profiling Model to generate the criminal's geographical profile, by combining two complementary strategies: the Spatial Distribution Strategy and the Probability Distance Strategy. In the first strategy, we designate the mean of all the known crime sites as the anchor point, and build a Standard Deviational Ellipse Model, considering the effect of landscape. In the second strategy, we take many factors such as the buffer zone and distance decay theory into consideration and calculate the probability of the offender's residence in a certain area by using the Bayesian Theorem and the Rossmo Algorithm. Then, we combine the result of two strategies and get three search areas suit different conditions of the police to track the serial criminal. Apply the model to the English serial killer Peter Sutcliffe's case, the calculation result shows that the model can effectively be used to track serial criminal.

  3. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  4. Spatial attention interacts with serial-order retrieval from verbal working memory.

    Science.gov (United States)

    van Dijck, Jean-Philippe; Abrahamse, Elger L; Majerus, Steve; Fias, Wim

    2013-09-01

    The ability to maintain the serial order of events is recognized as a major function of working memory. Although general models of working memory postulate a close link between working memory and attention, such a link has so far not been proposed specifically for serial-order working memory. The present study provided the first empirical demonstration of a direct link between serial order in verbal working memory and spatial selective attention. We show that the retrieval of later items of a sequence stored in working memory-compared with that of earlier items-produces covert attentional shifts toward the right. This observation suggests the conceptually surprising notion that serial-order working memory, even for nonspatially defined verbal items, draws on spatial attention.

  5. CT-guided needle biopsy of lung lesions: A survey of severe complication based on 9783 biopsies in Japan

    International Nuclear Information System (INIS)

    Tomiyama, Noriyuki; Yasuhara, Yoshifumi; Nakajima, Yasuo; Adachi, Shuji; Arai, Yasuaki; Kusumoto, Masahiko; Eguchi, Kenji; Kuriyama, Keiko; Sakai, Fumikazu; Noguchi, Masayuki; Murata, Kiyoshi; Murayama, Sadayuki; Mochizuki, Teruhito; Mori, Kiyoshi; Yamada, Kozo

    2006-01-01

    Purpose: The aim of our study was to update the rate of severe complications following CT-guided needle biopsy in Japan via a mailed survey. Materials and methods: Postal questionnaires regarding CT-guided needle biopsy were sent out to multiple hospitals in Japan. The questions regarded: the total number and duration of CT-guided lung biopsies performed at each hospital, and the complication rates and numbers of pneumothorax, hemothorax, air embolism, tumor seeding, tension pneumothorax and other rare complications. Each severe complication was followed with additional questions. Results: Data from 9783 biopsies was collected from 124 centers. Pneumothorax was the most common complication, and occurred in 2412 (35%) of 6881 cases. A total of 39 (35%) hospitals reported 74 (0.75%) cases with severe complications. There were six cases (0.061%) with air embolism, six cases (0.061%) with tumor seeding at the site of the biopsy route, 10 cases (0.10%) with tension pneumothorax, six cases (0.061%) with severe pulmonary hemorrhage or hemoptysis, nine cases (0.092%) with hemothorax, and 27 cases (0.26%) with others, including heart arrest, shock, and respiratory arrest. From a total of 62 patients with severe complications, 54 patients (0.55%) recovered without sequela, however one patient (0.01%) recovered with hemiplegia due to cerebral infarction, and the remaining seven patients (0.07%) died. Conclusions: This is the first national study documenting severe complications with respect to CT-guided needle biopsy in Japan. The complication rate in Japan is comparable to internationally published figures. We believe this data will improve both clinicians as well as patients understanding of the risk versus benefit of CT-guided needle biopsy, resulting better decisions

  6. Discrepancies between biopsy-based and excision-based grading of cervical intraepithelial neoplasia: the important role of time between excision and biopsy.

    Science.gov (United States)

    Zhang, Lu; Li, Qiang; Zhao, Mingyu; Jia, Lin; Zhang, Youzhong

    2015-05-01

    We sought to evaluate the rate of cervical intraepithelial neoplasia (CIN) ≤ 1 in loop electrosurgical excision procedure (LEEP) specimens after the treatment of biopsy-proven CIN 2-3, and to identify factors that are associated with the rate of CIN ≤ 1, especially focusing on the time interval between biopsy and LEEP. The goal of this research is to reduce the overtreatment of women with CIN 2-3. This was a retrospective study performed on women undergoing LEEP for biopsy-proven CIN 2-3 in Qilu hospital in Shandong, China. Patients were separated according to LEEP pathology (CIN ≤ 1 vs. CIN 2-3), and compared using the χ2 test and Student t test. The main outcome measures were pathologic discrepancy (defined as CIN 2-3 at biopsy, but CIN ≤ 1 at excision). Of the 391 women with biopsy-proven CIN 2-3, 26.9% had LEEP specimens with CIN ≤ 1 histologies. The likelihood of a CIN ≤ 1 LEEP specimen increases for greater biopsy-LEEP intervals (odds ratio, 1.374; 95% confidence interval, 1.089-1.735; P = 0.008). Cases in younger women and biopsy-assessed CIN 2 cases were both more likely to have CIN 1 or negative LEEP specimens. The rate of spontaneous histologic regression (defined as CIN ≤ 1 at resection) was 26.9%. These low-grade lesions were more common in LEEP specimens from young women with CIN 2 at biopsy, and who underwent LEEP later after the initial biopsy.

  7. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  8. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  9. Serial CSTR digester configuration for improving biogas production from manure

    DEFF Research Database (Denmark)

    Boe, Kanokwan; Angelidaki, Irini

    2009-01-01

    distribution ratio of 80/20 and 90/10, and total HRT of 15 days. The results showed that the serial CSTR could obtain 11% higher biogas yield compared to the single CSTR. The increased biogas yield in the serial CSTR was mainly from the second reactor, which accounted for 16% and 12% of total biogas yield......A new configuration of manure digesters for improving biogas production has been investigated in laboratory scale. A single thermophilic continuous-flow stirred tank reactor (CSTR) operated with a hydraulic retention time (HRT) of 15 days was compared to a serial CSTR configuration with volume...

  10. Liver Biopsy

    Science.gov (United States)

    ... called if any of the following occur: ● Persistent abdominal or chest pain ● Vomiting ● Pallor, weakness or dizziness ● Bleeding from the site of the biopsy ● Passage of tarry black stools For more information or to locate a pediatric gastroen- terologist in your area please visit our ...

  11. Whole-pattern fitting technique in serial femtosecond nanocrystallography

    Directory of Open Access Journals (Sweden)

    Ruben A. Dilanian

    2016-03-01

    Full Text Available Serial femtosecond X-ray crystallography (SFX has created new opportunities in the field of structural analysis of protein nanocrystals. The intensity and timescale characteristics of the X-ray free-electron laser sources used in SFX experiments necessitate the analysis of a large collection of individual crystals of variable shape and quality to ultimately solve a single, average crystal structure. Ensembles of crystals are commonly encountered in powder diffraction, but serial crystallography is different because each crystal is measured individually and can be oriented via indexing and merged into a three-dimensional data set, as is done for conventional crystallography data. In this way, serial femtosecond crystallography data lie in between conventional crystallography data and powder diffraction data, sharing features of both. The extremely small sizes of nanocrystals, as well as the possible imperfections of their crystallite structure, significantly affect the diffraction pattern and raise the question of how best to extract accurate structure-factor moduli from serial crystallography data. Here it is demonstrated that whole-pattern fitting techniques established for one-dimensional powder diffraction analysis can be feasibly extended to higher dimensions for the analysis of merged SFX diffraction data. It is shown that for very small crystals, whole-pattern fitting methods are more accurate than Monte Carlo integration methods that are currently used.

  12. Nerve Biopsy In The Diagnosis Of Leporsy

    OpenAIRE

    Hazra B; Banerjee P P; Bhattacharyya N K; Gupta P N; Barbhunia J N; Sanyal S

    1997-01-01

    Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borde...

  13. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  14. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  15. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  16. Serial killer: il database mondiale

    Directory of Open Access Journals (Sweden)

    Gaetano parente

    2016-07-01

    Full Text Available The complex and multisided study of serial killers is partly made difficult by the current level of progress that has led these deviant people to evolve in relation to the aspects of shrewdness (concerning the staging and mobility. Despite the important work of some scholars who proposed important theories, all this shows that, concerning serial murders, it is still particularly frequent not to pay attention to links among homicides committed by the same person but in different parts of the world. It is therefore crucial to develop a worldwide database that allows all police forces to access information collected on crime scenes of murders which are particularly absurd and committed without any apparent reason. It will then be up to the profiler, through ad hoc and technologically advanced tools, to collect this information on the crime scene that would be made available to all police forces thanks to the worldwide database.

  17. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  18. Temporal artery biopsies in south-east Scotland: a five year review.

    Science.gov (United States)

    Gajree, S; Borooah, S; Dhillon, N; Goudie, C; Smith, C; Aspinall, P; Dhillon, B

    2017-06-01

    Temporal artery biopsy is the gold standard investigation for the diagnosis of giant cell arteritis. The aim of this retrospective study was to investigate the use of temporal artery biopsy in diagnosing giant cell arteritis in south-east Scotland over a five-year period. We aimed to quantify success rates, and predictive factors for a positive biopsy, as well as compare the different specialities performing the biopsies. The data should enable the development of better criteria for referral for investigation of giant cell arteritis. Methods Patients were identified using a database of temporal artery biopsies generated by the pathology department in NHS Lothian (south east Scotland), for all biopsies examined between January 2010 and December 2015. An electronic patient record was used to retrospectively examine the records of patients in the database. Results A total of 715 biopsies were included in the study, of which 250 (35.0%) showed features of giant cell arteritis. The main predictors for a positive biopsy were age at biopsy, specialty performing biopsy, erythrocyte sedimentation rate, jaw claudication/pain, and ophthalmic symptoms. The most important predictor of a positive biopsy was erythrocyte sedimentation rate. The length of biopsy was not found to be a predictor of positive biopsy; however, diameter of biopsy was predictive. Conclusions We have shown that many temporal artery biopsies are negative, and finding ways to reduce the number of patients unnecessarily undergoing biopsy will be essential in reducing workload and streamlining services. This study demonstrates some key predictive factors for patients with positive biopsies. The study also shows that a large proportion of biopsies taking place do not result in the recommended length of specimen, but this does not necessarily reduce the likelihood of a positive biopsy.

  19. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  20. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  1. Numerical discrepancy between serial and MPI parallel computations

    Directory of Open Access Journals (Sweden)

    Sang Bong Lee

    2016-09-01

    Full Text Available Numerical simulations of 1D Burgers equation and 2D sloshing problem were carried out to study numerical discrepancy between serial and parallel computations. The numerical domain was decomposed into 2 and 4 subdomains for parallel computations with message passing interface. The numerical solution of Burgers equation disclosed that fully explicit boundary conditions used on subdomains of parallel computation was responsible for the numerical discrepancy of transient solution between serial and parallel computations. Two dimensional sloshing problems in a rectangular domain were solved using OpenFOAM. After a lapse of initial transient time sloshing patterns of water were significantly different in serial and parallel computations although the same numerical conditions were given. Based on the histograms of pressure measured at two points near the wall the statistical characteristics of numerical solution was not affected by the number of subdomains as much as the transient solution was dependent on the number of subdomains.

  2. Evaluation of lymphocytic exudative pleural effusion with pleural biopsy

    International Nuclear Information System (INIS)

    Khurram, M.; Jaffery, A.H.; Khar, Hamama-tul-Bushra; Malik, M.F.; Javed, S.; Burki, U.F.; Khan, B.A.; Ali, A.

    2002-01-01

    Objective: Evaluation of lymphocytic exudative pleural effusion by histopathological examination of pleural biopsy in patients with suspected tuberculous or malignant pleural effusion. Place and Duration of Study: The study was conducted at Pulmonology Department, Pakistan Institute of Medical Sciences, Islamabad and DHQ Teaching Hospital, Rawalpindi for two years 1999-2000. Subjects and Methods: A total of 120 patients with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4 biopsy specimens were obtained in each patient which were examined histopathologically. Patients in whom a definite diagnosis was not possible were further investigated with repeat pleural biopsy, sputum examinations, bronchoscopy etc. Results definite histopathological diagnosis with pleural biopsy was possible in 59 (49.16% patients, including 13 diagnosed on repeat pleural biopsy. Two commonest diagnoses made were tuberculosis and adenocarcinoma, 64.40% and 13.55% respectively. Conclusion: Histopathological evaluation of pleural biopsy specimens can lead to diagnosis in 49.16% patients with exudative lymphocytic pleural effusion. (author)

  3. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    Science.gov (United States)

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary

  4. A comparison of serial order short-term memory effects across verbal and musical domains.

    Science.gov (United States)

    Gorin, Simon; Mengal, Pierre; Majerus, Steve

    2018-04-01

    Recent studies suggest that the mechanisms involved in the short-term retention of serial order information may be shared across short-term memory (STM) domains such as verbal and visuospatial STM. Given the intrinsic sequential organization of musical material, the study of STM for musical information may be particularly informative about serial order retention processes and their domain-generality. The present experiment examined serial order STM for verbal and musical sequences in participants with no advanced musical expertise and experienced musicians. Serial order STM for verbal information was assessed via a serial order reconstruction task for digit sequences. In the musical domain, serial order STM was assessed using a novel melodic sequence reconstruction task maximizing the retention of tone order information. We observed that performance for the verbal and musical tasks was characterized by sequence length as well as primacy and recency effects. Serial order errors in both tasks were characterized by similar transposition gradients and ratios of fill-in:infill errors. These effects were observed for both participant groups, although the transposition gradients and ratios of fill-in:infill errors showed additional specificities for musician participants in the musical task. The data support domain-general serial order STM effects but also suggest the existence of additional domain-specific effects. Implications for models of serial order STM in verbal and musical domains are discussed.

  5. S3-1: The Serial Dependence of Visual Perception

    Directory of Open Access Journals (Sweden)

    David Whitney

    2012-10-01

    Full Text Available In our moment-to-moment perceptual experience, visual scenes can change, but objects rarely spontaneously come into or out of existence. The visual system may therefore delicately balance the need to optimize sensitivity to image changes (e.g., by adapting to changes in color, orientation, object identity, etc with the desire to represent the temporal continuity of objects—the likelihood that objects perceived at this moment tend to exist in subsequent moments. One way that the visual system may promote such stability is through the introduction of serial dependence to visual perception: by biasing the current percept toward what was seen at previous moments, the brain could compensate for variability in visual input that might otherwise disrupt perceptual continuity. Here, in two sets of experiments, we tested for serial dependence in visual perception of orientation and facial expression. We found that on a given trial, a subject's perception of the orientation of a grating reflected not only the currently viewed stimulus, but also a systematic attraction toward the orientations of the previously viewed stimuli. We found the same serial dependence in the perception of facial expression. This perceptual attraction extended over several trials and seconds, and displayed clear tuning to the difference (in orientation or facial expression between the sequential stimuli. Furthermore, serial dependence in object perception was spatially specific and selective to the attended object within a scene. Several control experiments showed that the perceptual serial dependence we report cannot be explained by effects of priming, known hysteresis effects, visual short-term memory, or expectation. Our results reveal a systematic influence of recent visual experiences on perception at any given moment: visual percepts, even of unambiguous stimuli, are attracted toward what was previously seen. We propose that such serial dependence helps to maintain

  6. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Some Considerations on Seriality and Synchronicity

    OpenAIRE

    Elena Nechita

    2010-01-01

    This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  8. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.

    Science.gov (United States)

    Goldstein, Mark A; Atri, Mostafa; O'Malley, Martin; Jacks, Lindsay; John, Rohan; Herzenberg, Andrew; Reich, Heather; Ghai, Sangeet

    2013-01-01

    The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.

  9. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  10. Muscle biopsies off-set normal cellular signaling in surrounding musculature

    DEFF Research Database (Denmark)

    Krag, Thomas O; Hauerslev, Simon; Dahlqvist, Julia R

    2013-01-01

    muscle tissue for at least 3 weeks after the biopsy was performed and magnetic resonance imaging suggests that an effect of a biopsy may persist for at least 5 months. Cellular signaling after a biopsy resembles what is seen in severe limb-girdle muscular dystrophy type 2I with respect to protein......Studies of muscle physiology and muscular disorders often require muscle biopsies to answer questions about muscle biology. In this context, we have often wondered if muscle biopsies, especially if performed repeatedly, would affect interpretation of muscle morphology and cellular signaling. We...... hypothesized that muscle morphology and cellular signaling involved in myogenesis/regeneration and protein turnover can be changed by a previous muscle biopsy in close proximity to the area under investigation. Here we report a case where a past biopsy or biopsies affect cellular signaling of the surrounding...

  11. [Gene expression analyses of kidney biopsies: the European renal cDNA bank--Kröner-Fresenius biopsy bank].

    Science.gov (United States)

    Cohen, C D; Kretzler, M

    2009-03-01

    Histological analysis of kidney biopsies is an essential part of our current diagnostic workup of patients with renal disease. Besides the already established diagnostic tools, new methods allow extensive analysis of the sample tissue's gene expression. Using results from a European multicenter study on gene expression analysis of renal biopsies, in this review we demonstrate that this novel approach not only expands the scope of so-called basic research but also might supplement future biopsy diagnostics. The goals are improved diagnosis and more specific therapy choice and prognosis estimates.

  12. A 16:1 Serializer ASIC for Data Transmission at 5 Gbps

    CERN Document Server

    Gong, D; The ATLAS collaboration

    2010-01-01

    A high speed, low power 16:1 serializer has been developed with a commercial 0.25 μm silicon-on-sapphire CMOS technology. The serializer operates from 4.0 to 5.7 Gbps. Total jitter is 62 ps and the eye openning of the bathtub curve is 122 ps at bit rate error of 10-12 at 5 Gbps. Power consumption is 463 mW at 5 Gbps. A proton beam test indicates the serializer is suitable for applications in high energy physics experiments.

  13. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  14. Migration of Gelfoam to the gallbladder after liver biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Chris [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada); Dalhousie University, School of Medicine, Halifax (Canada); Ahmed, Bilal [University of Toronto School of Medicine, Toronto (Canada); Doyle, John [The Hospital for Sick Children, Department of Hematology/Oncology, Toronto (Canada); Connolly, Bairbre L. [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada)

    2008-07-15

    Liver biopsy is a common procedure, with an inherent risk of bleeding. There are different ways to help avoid hemorrhage, including biopsy through a transjugular venous route or embolization of the tract with liquid or solid materials. We describe an image-guided percutaneous core needle liver biopsy with tract embolization using thick Gelfoam slurry in a pediatric oncology patient. Imaging studies acquired after the biopsy indicated that the Gelfoam mixture had likely migrated to the gallbladder and common bile duct. We report this rare occurrence with its striking imaging in order to make those performing biopsies aware of this possibility. (orig.)

  15. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  16. Serial Learning Process: Test of Chaining, Position, and Dual-Process Hypotheses

    Science.gov (United States)

    Giurintano, S. L.

    1973-01-01

    The chaining, position, and dual-process hypotheses of serial learning (SL) as well as serial recall, reordering, and relearning of paired-associate learning were examined to establish learning patterns. Results provide evidence for dual-process hypothesis. (DS)

  17. Use of a novel percutaneous biopsy localization device: initial musculoskeletal experience

    International Nuclear Information System (INIS)

    Roberts, C.C.; Morrison, W.B.; Deely, D.M.; Zoga, A.C.; Koulouris, G.; Winalski, C.S.

    2007-01-01

    To preliminarily evaluate a new CT-biopsy guidance device, the SeeStar (Radi, Uppsala, Sweden), for use in musculoskeletal applications. The device was evaluated using an imaging phantom and in various simulated clinical biopsy situations. The phantom study was undertaken to optimize the linear metallic artifacts produced by the guidance device. The phantom and guidance device were imaged with CT after altering different imaging parameters, including field of view, filter, focal spot size, kV, mAs, slice thickness and pitch. Clinical biopsy situations were simulated for a superficial biopsy, a deep biopsy and a horizontal biopsy approach. Altering CT parameters had little effect on the subjective appearance of the linear metal artifact, which is used to plan the biopsy approach. Placement of an 18-G needle inside of the biopsy device was subjectively helpful in exaggerating the artifact. Use of this artifact could be helpful in planning biopsy approach for deep lesions or lesions near critical structures. The metal guide on the device adequately supports a standard biopsy needle, making it potentially advantageous for biopsy of superficial lesions and lesions approached from a horizontal orientation. Use of this CT-biopsy guidance device is potentially useful for musculoskeletal applications. The linear metal artifact produced by the device can help plan the biopsy approach. The device can also be useful in biopsy situations where the biopsy needle requires external support during imaging. (orig.)

  18. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  19. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  20. Reoperative sentinel lymph node biopsy after previous mastectomy.

    Science.gov (United States)

    Karam, Amer; Stempel, Michelle; Cody, Hiram S; Port, Elisa R

    2008-10-01

    Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, but many clinical scenarios questioning the validity of SLN biopsy remain. Here we describe our experience with reoperative-SLN (re-SLN) biopsy after previous mastectomy. Review of the SLN database from September 1996 to December 2007 yielded 20 procedures done in the setting of previous mastectomy. SLN biopsy was performed using radioisotope with or without blue dye injection superior to the mastectomy incision, in the skin flap in all patients. In 17 of 20 patients (85%), re-SLN biopsy was performed for local or regional recurrence after mastectomy. Re-SLN biopsy was successful in 13 of 20 patients (65%) after previous mastectomy. Of the 13 patients, 2 had positive re-SLN, and completion axillary dissection was performed, with 1 having additional positive nodes. In the 11 patients with negative re-SLN, 2 patients underwent completion axillary dissection demonstrating additional negative nodes. One patient with a negative re-SLN experienced chest wall recurrence combined with axillary recurrence 11 months after re-SLN biopsy. All others remained free of local or axillary recurrence. Re-SLN biopsy was unsuccessful in 7 of 20 patients (35%). In three of seven patients, axillary dissection was performed, yielding positive nodes in two of the three. The remaining four of seven patients all had previous modified radical mastectomy, so underwent no additional axillary surgery. In this small series, re-SLN was successful after previous mastectomy, and this procedure may play some role when axillary staging is warranted after mastectomy.

  1. The Effect of Concurrent Semantic Categorization on Delayed Serial Recall

    Science.gov (United States)

    Acheson, Daniel J.; MacDonald, Maryellen C.; Postle, Bradley R.

    2011-01-01

    The influence of semantic processing on the serial ordering of items in short-term memory was explored using a novel dual-task paradigm. Participants engaged in 2 picture-judgment tasks while simultaneously performing delayed serial recall. List material varied in the presence of phonological overlap (Experiments 1 and 2) and in semantic content…

  2. Infants' Memory Processing of a Serial List: List Length Effects.

    Science.gov (United States)

    Gulya, Michele; Sweeney, Becky; Rovee-Collier, Carolyn

    1999-01-01

    Three experiments demonstrated that increasing the length of a mobile serial list impaired 6-month olds' memory for serial order. Findings indicated that the primacy effect was absent on a 24-hour delayed recognition test and was exhibited on a reactivation test, adding to growing evidence that young infants possess two functionally distinct…

  3. Position Analysis of a Hybrid Serial-Parallel Manipulator in Immersion Lithography

    Directory of Open Access Journals (Sweden)

    Jie-jie Shao

    2015-01-01

    Full Text Available This paper proposes a novel hybrid serial-parallel mechanism with 6 degrees of freedom. The new mechanism combines two different parallel modules in a serial form. 3-P̲(PH parallel module is architecture of 3 degrees of freedom based on higher joints and specializes in describing two planes’ relative pose. 3-P̲SP parallel module is typical architecture which has been widely investigated in recent researches. In this paper, the direct-inverse position problems of the 3-P̲SP parallel module in the couple mixed-type mode are analyzed in detail, and the solutions are obtained in an analytical form. Furthermore, the solutions for the direct and inverse position problems of the novel hybrid serial-parallel mechanism are also derived and obtained in the analytical form. The proposed hybrid serial-parallel mechanism is applied to regulate the immersion hood’s pose in an immersion lithography system. Through measuring and regulating the pose of the immersion hood with respect to the wafer surface simultaneously, the immersion hood can track the wafer surface’s pose in real-time and the gap status is stabilized. This is another exploration to hybrid serial-parallel mechanism’s application.

  4. Motor cortical encoding of serial order in a context-recall task.

    Science.gov (United States)

    Carpenter, A F; Georgopoulos, A P; Pellizzer, G

    1999-03-12

    The neural encoding of serial order was studied in the motor cortex of monkeys performing a context-recall memory scanning task. Up to five visual stimuli were presented successively on a circle (list presentation phase), and then one of them (test stimulus) changed color; the monkeys had to make a single motor response toward the stimulus that immediately followed the test stimulus in the list. Correct performance in this task depends on memorization of the serial order of the stimuli during their presentation. It was found that changes in neural activity during the list presentation phase reflected the serial order of the stimuli; the effect on cell activity of the serial order of stimuli during their presentation was at least as strong as the effect of motor direction on cell activity during the execution of the motor response. This establishes the serial order of stimuli in a motor task as an important determinant of motor cortical activity during stimulus presentation and in the absence of changes in peripheral motor events, in contrast to the commonly held view of the motor cortex as just an "upper motor neuron."

  5. Pleural needle biopsy

    Science.gov (United States)

    ... own. Sometimes, a chest tube is needed to drain the air and expand the lung. There is also a chance of excessive blood loss. Considerations If a closed pleural biopsy is not enough to make a diagnosis, ...

  6. Reaction kinetics in open reactors and serial transfers between closed reactors

    Science.gov (United States)

    Blokhuis, Alex; Lacoste, David; Gaspard, Pierre

    2018-04-01

    Kinetic theory and thermodynamics of reaction networks are extended to the out-of-equilibrium dynamics of continuous-flow stirred tank reactors (CSTR) and serial transfers. On the basis of their stoichiometry matrix, the conservation laws and the cycles of the network are determined for both dynamics. It is shown that the CSTR and serial transfer dynamics are equivalent in the limit where the time interval between the transfers tends to zero proportionally to the ratio of the fractions of fresh to transferred solutions. These results are illustrated with a finite cross-catalytic reaction network and an infinite reaction network describing mass exchange between polymers. Serial transfer dynamics is typically used in molecular evolution experiments in the context of research on the origins of life. The present study is shedding a new light on the role played by serial transfer parameters in these experiments.

  7. Computed tomography guided needle biopsy: experience from 1,300 procedures

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Isberner, Rony Klaus; Viana, Luciana Marinho; Yu, Liao Shin; Aita, Alessandro Amorim; Soares, Fernando Augusto [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radiologia e Patologia

    2006-01-15

    Context and objective: computed tomography (CT) guided biopsy is widely accepted as effective and safe for diagnosis in many settings. Accuracy depends on target organ and needle type. Cutting needles present advantages over fine needles. This study presents experience from CT guided biopsies performed at an oncology center. Design and setting: retrospective study at Hospital do Cancer A. C. Camargo, Sao Paulo.Methods: 1,300 consecutive CT guided biopsies performed between July 1994 and February 2000 were analyzed. Nodules or masses were suspected as primary malignancy in 845 cases (65%) or metastatic lesion in 455 (35%). 628 lesions were thoracic, 281 abdominal, 208 retroperitoneal, 134 musculoskeletal and 49 head/neck. All biopsies were performed by one radiologist or under his supervision: 765 (59%) with 22-gauge fine-needle/aspiration technique and 535 (41%) with automated 16 or 18-gauge cutting-needle biopsy. Results: adequate samples were obtained in 70-92% of fine-needle and 93-100% of cutting-needle biopsies. The specific diagnosis rates were 54-67% for fine-needle and 82-100% for cutting-needle biopsies, according to biopsy site. For any site, sample adequacy and specific diagnosis rate were always better for cutting-needle biopsy. Among 530 lung biopsies, there were 84 pneumothorax (16%) and two hemothorax (0.3%) cases, with thoracic drainage in 24 (4.9%). Among abdominal and retroperitoneal biopsies, there were two cases of major bleeding and one of peritonitis. Conclusion: both types of needle showed satisfactory results, but cutting-needle biopsy should be used when specific diagnosis is desired without greater incidence of complications. (author)

  8. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  9. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  10. The criteria for the decision of transrectal US-guided prostate biopsy: Can we reduce the number of unnecessary biopsies?

    International Nuclear Information System (INIS)

    Cho, Joon Hyung; Cho, Jae Ho; Ahn, Jay Hong; Chang, Jay Chun

    2001-01-01

    To establish the criteria which can safely reduce the number of unnecessary biopsies by comparing the transrectal ultrasonography (TRUS) findings, serum prostate-specific antigen (PSA), and prostate specific antigen density (PSAD) in the decision of criteria for the prostatic biopsy using TRUS. Two hundred and twenty patients underwent TRUS- guided prostate biopsy due to elevated PSA and/or focal nodule on TRUS were included. Sixty five (27.5%) patients were confirmed as prostate cancer, and remained 155 (70.5%) patients were reported as benign diseases including benign prostate hyperplasia. The sensitivity, specificity and accuracy of TRUS, PSA and PSAD were evaluated and the single criterion or the combination of the criteria which can safely reduce the unnecessary biopsies without missing prostatic cancer were investigated. The sensitivity, specificity and accuracy of TRUS, PSA (cut-off value, 4 ng/ml) and PSAD (cut-off level, 0.2 ng/ml/cm 3 ) were 78.5%/95.4%/95.4%/27.8%/51.6%/64/5%, 42.7%/64.5%/73.6%, respectively. PSAD cut-off level 0.2 ng/ml/cm 3 was the most excellent single criterion for the decision of prostatic biopsy and the number of unnecessary biopsies was 100 cases. But 3 cases of prostatic cancer which the PSAD level was below 0.2 ng/ml/cm 3 were included and in all these 3 cases, a focal nodule was detected on TRUS. Therefore, we applied these two criteria at once and the biopsies of 30 cases (13.6%) are unnecessary. With the single criterion, we could not obtain the satisfactory results but by the combinations of criteria (TRUS and PSAD), 30 (13.6%) cases are unnecessary biopsies without missing cancer. We think that the short term follow-up may be a substitute for the immediate when nodular lesion is suspicious on TRUS and serum PSAD level is below 0.2 ng/ml/cm 3 .

  11. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    International Nuclear Information System (INIS)

    Vandervelde, C.; Kamani, T.; Varghese, A.; Ramesar, K.; Grace, R.; Howlett, D.C.

    2008-01-01

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status

  12. A study to evaluate the efficacy of image-guided core biopsy in the diagnosis and management of lymphoma-Results in 103 biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Vandervelde, C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: clivevandervelde@gmail.com; Kamani, T. [Department of ENT Surgery, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: tkamany@yahoo.com; Varghese, A. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: vargheseajay@hotmail.com; Ramesar, K. [Department of Histopathology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: keith.ramesar@esht.nhs.uk; Grace, R. [Department of Haematology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: richard.grace@esht.nhs.uk; Howlett, D.C. [Department of Radiology, Eastbourne District General Hospital, Kings Drive, Eastbourne, East Sussex BN21 2UD (United Kingdom)], E-mail: david.howlett@esht.nhs.uk

    2008-04-15

    The reason for this study was to evaluate the ability of image-guided core biopsy to replace surgical excision by providing sufficient diagnostic and treatment information. All consecutive image-guided core biopsies in patients with a final diagnosis of lymphoma over a 6-year period at our institution were collected retrospectively. Case notes and pathology reports were reviewed and the diagnostic techniques used were recorded. Pathology reports were graded according to their diagnostic completeness and their ability to provide treatment information. Out of a total of 328 instances of lymphoma, 103 image-guided core biopsies were performed in 96 patients. In 78% of these, the diagnostic information obtained from the biopsy provided a fully graded and subtyped diagnosis of lymphoma with sufficient information to initiate therapy. In the head and neck 67% of core biopsies were fully diagnostic for treatment purposes compared to 91% in the thorax, abdomen and pelvis. Image-guided core biopsy has a number of cost and safety advantages over surgical excision biopsy and in suitable cases it can obviate the need for surgery in cases of suspected lymphoma. This is especially relevant for elderly patients and those with poor performance status.

  13. The effects of nidopallium caudolaterale inactivation on serial-order behaviour in pigeons (Columba livia).

    Science.gov (United States)

    Johnston, Melissa Jane; Clarkson, Andrew N; Gowing, Emma K; Scarf, Damian; Colombo, Mike

    2018-06-06

    Serial-order behaviour is the ability to complete a sequence of responses in a predetermined order to achieve a reward. In birds, serial-order behaviour is thought to be impaired by damage to the nidopallium caudolaterale (NCL). In the current study, we examined the role of the NCL in serial-order behaviour by training pigeons on a 4-item serial-order task and a go/no-go discrimination task. Following training, pigeons were received infusions of 1μl of either tetrodotoxin (TTX) or saline. Saline infusions had no impact on serial-order behaviour whereas TTX infusions resulted in a significant decrease in performance. The serial-order impairments, however, were not the results of errors of any specific error at any specific list item. With respect to the go/no-go discrimination task, saline infusions also had no impact on performance whereas TTX infusions impaired pigeons' discrimination abilities. Given the impairments on the go/no-go discrimination task, which does not require processing of serial-order information, we tentatively conclude that damage to the NCL does not impair serial-order behaviour per se, but rather results in a more generalised impairment that may impact performance across a range of tasks.

  14. Some Considerations on Seriality and Synchronicity

    Directory of Open Access Journals (Sweden)

    Elena Nechita

    2010-01-01

    Full Text Available This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  15. Percutaneous Native Renal Biopsy Adequacy: A Successful Interdepartmental Quality Improvement Activity

    Directory of Open Access Journals (Sweden)

    Laurette Geldenhuys

    2015-03-01

    Full Text Available Background: An adequate renal biopsy is essential for diagnosis and treatment of medical renal disease. Objective: We evaluated two initiatives to improve adequacy of renal biopsy samples at our centre. Design: Retrospective determination of renal biopsy adequacy. Setting: Queen Elizabeth II Health Sciences Centre. Patients: Patients undergoing medical renal biopsies. Measurements: Renal biopsy adequacy. Methods: The first initiative was to restrict the performance of biopsies to a smaller group of radiologists and to include a comment on biopsy adequacy in every pathology report. The second initiative was to introduce on-site adequacy assessment by a medical laboratory technologist. Native renal and allograft biopsy adequacies were calculated for three periods: 1 baseline, October 2005 to September 2006; 2 after implementation of the first initiative, January 2007 to September 2011; and 3 after implementation of the second initiative, October 2011 to September 2012. A subset of native renal biopsies was examined to determine if there was a relationship between adequacy and number of passes. Results: The percentages of adequate native renal biopsies during the first, second, and third periods were 31%, 72% and 90%, respectively. This represents a significant increase (40%, p < 0.0001 in adequacy following the first initiative, and another significant increase (18%, p = 0.0003 following the second initiative. The percentages of adequate renal allograft biopsies during the first, second, and third periods were 75%, 56% and 69%, respectively. These changes in adequacy were not statistically significant. In the subset of native renal biopsies examined, a biopsy comprising more than three cores was not associated with increase in adequacy. Limitations: The most important limitation is the lack of generally accepted and applied adequacy criteria limiting generalizability of our findings. Conclusions: Restricting the performance of biopsies to

  16. Percutaneous biopsy of non-palpable breast lesions with the advanced breast biopsy instrumentation (ABBI): analysis of indication strategies

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Otto, U.; Buitrago-Tellez, C.; Bremerich, J.; Bongartz, G.; Oertli, D.; Torhorst, J.

    2001-01-01

    Purpose: To compare the indications for biopsy with and without the use of the Breast Imaging Reporting and Data System. Material and methods: Biopsies using the ABBI were performed in 62 patients with 64 non-palpable evident mammographic lesions. The initial decision for biopsy was made by non-radiologists due to suspicious microcalcifications (n=53) and masses (n=11). The indication was retrospectively reassessed by adopting the BI-RADS classification by three radiologists in consensus. The positive predictive value (PPV) of both indication strategies was assessed and compared. Results: Biopsies adopting ABBI were performed without major side-effects and were diagnostic. Carcinoma was present in 14 lesions: nine specimens were diagnosed as DCIS and five as invasive carcinomas. For the 50 benign lesions histology revealed mastopathies (26/50) and fibroadenomas (8/50) as the most frequent diagnosis. The positive predictive value (PPV) for the initial indication was 22%, whereas PPV for BI-RADS based indications (categories 4 and 5) was 31%. Conclusion: ABBI enables stereotactically-guided procedures that result in representative and diagnostic biopsies. Standardized criteria like BI-RADS improve the PPV and should be a mandatory part of mammographic evaluation. Radiologists should remain involved in the decision making. (orig.) [de

  17. Medially Directed TRUS Biopsy of the Prostate: Clinical Utility and Optimal Protocol

    International Nuclear Information System (INIS)

    Park, Byung Kwan; Kim, Seung Hyup

    2012-01-01

    The objective of this study is to determine whether medially directed transrectal ultrasound (TRUS)-guided biopsy is necessary for detection of prostate cancer and for establishment of an optimal biopsy regimen that is equivalent to a systematic 12 core biopsy. A total of 302 patients underwent a TRUS-guided systematic 12 core biopsy consisting of both medial sextant biopsy obtained between the parasagittal line and midline and lateral sextant biopsy obtained between the parasagittal line and lateral border. We obtained cancer detection rates of various biopsy regimens that were produced from a systematic 12 core biopsy. Using a systematic 12 core biopsy, cancer was detected in 116 (38.4%) of 302 patients. No significant difference was observed between cancer detection rates of medial sextant biopsy and lateral sextant biopsy (33.8% versus 31.5%, p >.05). Biopsy regimens that were equivalent to the systematic 12 core regarding cancer detection rate included medially directed cores that were obtained from both medial portions of the apex. Both medially directed biopsy and laterally directed biopsy are necessary for detection of prostate cancer and for establishment of an optimal biopsy regimen.

  18. Gamma Imaging-Guided Minimally Invasive Breast Biopsy: Initial Clinical Experience.

    Science.gov (United States)

    Brem, Rachel F; Mehta, Anita K; Rapelyea, Jocelyn A; Akin, Esma A; Bazoberry, Adriana M; Velasco, Christel D

    2018-03-01

    The purpose of this study was to evaluate our initial experience with gamma imaging-guided vacuum-assisted breast biopsy in women with abnormal findings. A retrospective review of patients undergoing breast-specific gamma imaging (BSGI), also known as molecular breast imaging (MBI), between April 2011 and October 2015 found 117 nonpalpable mammographically and sonographically occult lesions for which gamma imaging-guided biopsies were recommended. Biopsy was performed with a 9-gauge vacuum-assisted device with subsequent placement of a titanium biopsy site marker. Medical records and pathologic findings were evaluated. Of the 117 biopsies recommended, 104 were successful and 13 were canceled. Of the 104 performed biopsies, 32 (30.8%) had abnormal pathologic findings. Of those 32 biopsies, nine (28.1%) found invasive cancers, six (18.8%) found ductal carcinoma in situ (DCIS), and 17 (53.1%) found high-risk lesions. Of the 17 high-risk lesions, there were three (17.6%) lobular carcinomas in situ, five (29.4%) atypical ductal hyperplasias, two (11.8%) atypical lobular hyperplasias, one (5.9%) flat epithelial atypia, and six (35.3%) papillomas. Two cases of atypical ductal hyperplasia were upgraded to DCIS at surgery. The overall cancer detection rate for gamma imaging-guided biopsy was 16.3%. In this study, gamma imaging-guided biopsy had a positive predictive value of total successful biopsies of 16.3% for cancer and 30.8% for cancer and high-risk lesions. Gamma imaging-guided biopsy is a viable approach to sampling BSGI-MBI-detected lesions without sonographic or mammographic correlate. Our results compare favorably to those reported for MRI-guided biopsy.

  19. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  20. [Personality disorders, psychopathy and serial killers].

    Science.gov (United States)

    Morana, Hilda C P; Stone, Michael H; Abdalla-Filho, Elias

    2006-10-01

    To illustrate the basic characteristics of several specific personality disorders, focusing mainly in antisocial personality disorder. The differences between antisocial personality disorder and psychopathy are highlighted. Serial killers and its psychopathic aspects are also discussed. A bibliographic review was completed in order to outline convergences and divergences among different authors about this controversial issue, especially those concerning the possibility of treatment. While anti-social personality disorder is a medical diagnosis, the term "psychopathy" (which belongs to the sphere of forensic psychiatry) may be understood as a "legal diagnosis". It is not still possible to identify an effective treatment for serial killers. Personality disorders, especially of the antisocial type, still represent a formidable challenge to forensic psychiatry today. Questions as yet unanswered include the best and most humane place for patients with this condition and the nature of a standardised treatment recommendation.

  1. How Do We Write about Performance in Serial Television?

    OpenAIRE

    Elliott Logan

    2015-01-01

    Television studies has produced few sustained analyses of performance in serial television. Yet film studies scholarship has shown how attending to the integration of performances with other aspects of film style is crucial to the interpretation and appreciation of expression and meaning in filmed narrative fictions. However, as a particle form of filmed serial narrative, series television raises a number of questions about performance that will not necessarily be satisfyingly addressed by th...

  2. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    Science.gov (United States)

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  3. Serial cranial ultrasonography or early MRI for detecting preterm brain injury?

    NARCIS (Netherlands)

    Plaisier, Annemarie; Raets, Marlou M A; Ecury-Goossen, Ginette M; Govaert, Paul; Feijen-Roon, Monique; Reiss, Irwin K M; Smit, Liesbeth S; Lequin, Maarten H; Dudink, Jeroen

    OBJECTIVE: To investigate detection ability and feasibility of serial cranial ultrasonography (CUS) and early MRI in preterm brain injury. DESIGN: Prospective cohort study. SETTING: Level III neonatal intensive care unit. PATIENTS: 307 infants, born below 29 weeks of gestation. METHODS: Serial CUS

  4. Are breast biopsies adequately funded? A process cost and revenue analysis

    International Nuclear Information System (INIS)

    Hahn, M.; Fischbach, E.; Fehm, T.

    2011-01-01

    Purpose: The objective of the study was to determine whether the various breast biopsy procedures specified in the S 3 guidelines are sensibly represented within the current German health system as considered from a cost evaluation perspective. Materials and Methods: This prospectively designed multicenter study analyzed 221 breast biopsies at 7 institutions from 04/2006 to 01/2007. Core needle biopsies, vacuum-assisted biopsies and surgical open biopsies under sonographic or mammographic guidance were evaluated. During an analysis of process costs, the individual process steps were recorded in diagrammatic form and assigned to the true consumption of resources. The actual resource consumption costs were entered. A process-related breakeven analysis was conducted to check whether the reimbursement of individual biopsy types covers the costs. Results: Only sonographically guided core needle biopsy and surgical open biopsy are adequately reimbursed in the current German health system. All other breast biopsies indicate a negative profit margin. The principal reasons for underfunding are found in the area of reimbursement of investment and non-personnel costs. Conclusion: The reimbursement of breast biopsies must be improved in order to guarantee nationwide care of the population using the breast biopsy methods recommended in the S 3 guidelines and to avoid disincentives with respect to breast biopsy indications. (orig.)

  5. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    Science.gov (United States)

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Paths to destruction: the lives and crimes of two serial killers.

    Science.gov (United States)

    Wolf, Barbara C; Lavezzi, Wendy A

    2007-01-01

    Although research into the phenomenon of serial murder has revealed that serial killers frequently do not fit the initially described paradigm in terms of their physical and psychological profiles, backgrounds, and motives to kill, the media continues to sensationalize the figures of such killers and the investigators who attempt to analyze them on the basis of aspects of their crimes. Although the so-called "typical" profile of the serial murderer has proven accurate in some instances, in many other cases the demographics and behaviors of these killers have deviated widely from the generalized assumptions. This report details two unusual cases in which five and eight murders were committed in upstate New York. The lives and crimes of these offenders illustrate the wide spectrum of variations in the backgrounds, demographics, motivations, and actions witnessed among serial murderers, and highlight the limitations and dangers of profiling based on generalities.

  7. Morphologic Features Suggestive of Endometriosis in Nondiagnostic Peritoneal Biopsies.

    Science.gov (United States)

    Harrison, Beth T; Mittal, Khush

    2015-11-01

    Endometriosis is a common disorder that causes significant morbidity from dysmenorrhea, pelvic pain, and subfertility. Establishment of a definitive diagnosis has important therapeutic implications; however, only approximately 50% of biopsies of laparoscopically suspicious areas provide a diagnosis of endometriosis. Histologic criteria for diagnosis require the presence of endometrial glands or endometrial-type stroma. We hypothesize that other frequently present, but nondiagnostic, histologic features of endometriosis suggest its presence in patients with nondiagnostic peritoneal biopsies. We performed a retrospective clinicopathologic study of morphologic and immunohistochemical features that may improve the histologic diagnosis of endometriosis on laparoscopic peritoneal biopsies. We compared diagnostic (n=88) and nondiagnostic (n=54) peritoneal biopsies from pathologically confirmed endometriosis cases with negative peritoneal biopsies (n=84) from early-stage gynecologic cancer cases. Statistical analysis utilized the Fisher exact test. Multiple morphologic features were significantly increased in nondiagnostic biopsies from patients with endometriosis in comparison with those from negative controls, including foamy macrophages (P=0.0001) and submesothelial stromal clusters (SSCs) (P=0.0008). SSCs ranged from subtle aggregates of spindle cells to nodules of whorled spindle cells with small vessels and extravasated red blood cells resembling stromal endometriosis. Immunohistochemical studies confirmed that ER and CD10-positive SSCs were present in a greater proportion of both nondiagnostic and diagnostic peritoneal biopsies and at a greater number of lesions per biopsy. The overall histologic detection rate of peritoneal biopsies for endometriosis was 62.0%, and inclusion of SSCs with or without foamy macrophages in the diagnostic criteria appreciably increased this rate to between 72.5% and 76.8%. We describe SSCs, which appear to be an early or less developed

  8. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy.

  9. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy. CT‑guided percutaneous ...

  10. New developments in electron microscopy for serial image acquisition of neuronal profiles.

    Science.gov (United States)

    Kubota, Yoshiyuki

    2015-02-01

    Recent developments in electron microscopy largely automate the continuous acquisition of serial electron micrographs (EMGs), previously achieved by laborious manual serial ultrathin sectioning using an ultramicrotome and ultrastructural image capture process with transmission electron microscopy. The new systems cut thin sections and capture serial EMGs automatically, allowing for acquisition of large data sets in a reasonably short time. The new methods are focused ion beam/scanning electron microscopy, ultramicrotome/serial block-face scanning electron microscopy, automated tape-collection ultramicrotome/scanning electron microscopy and transmission electron microscope camera array. In this review, their positive and negative aspects are discussed. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Rehearsal in serial memory for visual-spatial information: evidence from eye movements.

    Science.gov (United States)

    Tremblay, Sébastien; Saint-Aubin, Jean; Jalbert, Annie

    2006-06-01

    It is well established that rote rehearsal plays a key role in serial memory for lists of verbal items. Although a great deal of research has informed us about the nature of verbal rehearsal, much less attention has been devoted to rehearsal in serial memory for visual-spatial information. By using the dot task--a visual-spatial analogue of the classical verbal serial recall task--with delayed recall, performance and eyetracking data were recorded in order to establish whether visual-spatial rehearsal could be evidenced by eye movement. The use of eye movement as a form of rehearsal is detectable (Experiment 1), and it seems to contribute to serial memory performance over and above rehearsal based on shifts of spatial attention (Experiments 1 and 2).

  12. SMALL SERIAL AND SERIAL PRODUCTION MANAGEMENT IN UNSTABLE DEMAND ENVIROUMENT

    Directory of Open Access Journals (Sweden)

    Tsomaeva I. V.

    2014-03-01

    Full Text Available The work presents the methodological approach to production program of the enterprise serial engineering for the current period in the conditions of uncertainty of demand. Here are two problems with this. The first is connected with the formation of the production program of the next quarter, year. Objective could be to stochastic programming, but this task is difficult. Therefore, in this paper we proposed a simple solution. On the basis of statistical historical information about the deviation of actual sales data products from predicted by Monte Carlo generated a lot of production programs. Fixed worst key performance (sales, profit etc. The difference between the values of the planned target and the settlement defines stochastic reserve, to be established at the expense of additional innovations. The second problem is connected with the formation of the production program production in the planned month, taking into account the creation of stocks of production in the conditions when for a short period of time is difficult to build a pattern of change in the quantity demanded by month for serial production, as in some months of the year the products are not produced nor sold. To justify the level of inventories of finished products is information on deviations from the fact plan for past periods. Built function of frequency distribution of the values of deviations. This allows you to further build the methodology for determining the level of production (taking into account the reserves and sales of products that deliver maximum economic effect from the sales in the conditions of a random process of realization of production.

  13. DDCMP protocol on a DMA serial-line board

    International Nuclear Information System (INIS)

    Hunt, D.N.; Kessler, G.C.

    1982-01-01

    The Nuclear Chemistry Division of Lawrence Livermore National Laboratory is in the midst of an upgrade to their radiation counting facility. The result of this upgrade wil be a computer-based data acquisition network, the Nuclear Chemistry Counting Facility Network (NCCF-NET). This network will consist of forty dedicated LSI-11/2 based controllers, ten interactive LSI-11/23 based workstations and a VAX-11/750 central node for data reduction and storage. One of the data acquisition instruments used in this network is a Nuclear Data pulse-height analyzer, the ND66L. This analyzer communicates to a host system over a 9600-baud serial line, using the DDCMP link level protocol. In order to relieve the host computer from the overhead of handling the DDCMP protocol, an in-house designed DMA serial line board was implemented to communicate with the ND66L. The hardware used and its environment will be duscussed along with the design and implementation of the firmware, which implements the serial DDCMP link

  14. A network-based Macintosh serial host interface program

    International Nuclear Information System (INIS)

    Wight, J.

    1991-03-01

    A program has been written for the Apple Macintosh to replace conventional host RS232 terminals with customizable user interfaces. Serial port NuBus cards in the Macintosh allow many simultaneous sessions to be maintained. A powerful system is attained by connecting multiple Macintoshes on a network, each running this program. Each is then able to share incoming data from any of its serial ports with any other Macintosh, as well as accept data from any other Macintosh for output to any of its serial ports. The program has been used to eliminate multiple host terminals, modernize the user interface, and to centralize operation of a complex control system. Minimal changes to host software have been required. By making extensive use of Macintosh resources, the same executable code serves in a variety of roles. An object oriented C language with a class library made the development straightforward and easy to modify. This program is used to control a 2 MW neutral beam system on the DIII-D magnetic fusion tokamak. 7 figs

  15. Aspiration biopsy of testis: another method for histologic examination

    International Nuclear Information System (INIS)

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-01-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective

  16. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  17. Serial casting for reconstruction of a deformed Charcot foot: a case report.

    Science.gov (United States)

    Rosenblum, Jonathan I; Weiss, Shmuel; Gazes, Michael; Amit-Kohn, Michal

    2015-05-01

    Charcot neuroarthropathy may occur in patients with peripheral neuropathy who do not notice pain while their bones and joints collapse or breakdown under the constant pressure of body weight. This can lead to ulcerations from severe deformity and potentially limb-threatening and life-threatening infections. Current treatments vary from immobilization to extensive reconstructive surgical interventions. Serial casting, used to correct many pediatric deformities while bones are often more pliable, was used with a 63-year-old male patient who presented with an active phase of Charcot foot with ulceration. The patient previously underwent foot reconstruction and had all hardware removed prior to serial casting. Due to the potential pliability of the bones, serial casting was attempted to reform the shape and position of the foot in a reverse Ponseti-type serial casting to create a more stable structure with less deformity that could lead to epithelial breakdown. The patient regained full ambulation with a plantargrade foot and no wounds, and was followed without complications for 36 months. Serial weekly casting was an effective modality for treatment of this patient's Charcot foot deformity.

  18. The utilization of forensic science and criminal profiling for capturing serial killers.

    Science.gov (United States)

    White, John H; Lester, David; Gentile, Matthew; Rosenbleeth, Juliana

    2011-06-15

    Movies and nightly television shows appear to emphasize highly efficient regimens in forensic science and criminal investigative analysis (profiling) that result in capturing serial killers and other perpetrators of homicide. Although some of the shows are apocryphal and unrealistic, they reflect major advancements that have been made in the fields of forensic science and criminal psychology during the past two decades that have helped police capture serial killers. Some of the advancements are outlined in this paper. In a study of 200 serial killers, we examined the variables that led to police focusing their attention on specific suspects. We developed 12 categories that describe how serial killers come to the attention of the police. The results of the present study indicate that most serial killers are captured as a result of citizens and surviving victims contributing information that resulted in police investigations that led to an arrest. The role of forensic science appears to be important in convicting the perpetrator, but not necessarily in identifying the perpetrator. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Spatial patterns of serial murder: an analysis of disposal site location choice.

    Science.gov (United States)

    Lundrigan, S; Canter, D

    2001-01-01

    Although the murders committed by serial killers may not be considered rational, there is growing evidence that the locations in which they commit their crimes may be guided by an implicit, if limited rationality. The hypothesized logic of disposal site choice of serial killers led to predictions that (a) their criminal domains would be around their home base and relate to familiar travel distances, (b) they would have a size that was characteristic of each offender, (c) the distribution would be biased towards other non-criminal activities, and (d) the size of the domains would increase over time. Examination of the geographical distribution of the sites at which 126 US and 29 UK serial killers disposed of their victims' bodies supported all four hypotheses. It was found that rational choice and routine activity models of criminal behavior could explain the spatial choices of serial murderers. It was concluded that the locations at which serial killers dispose of their victims' bodies reflect the inherent logic of the choices that underlie their predatory activities. Copyright 2001 John Wiley & Sons, Ltd.

  20. Assessing Working Memory in Mild Cognitive Impairment with Serial Order Recall.

    Science.gov (United States)

    Emrani, Sheina; Libon, David J; Lamar, Melissa; Price, Catherine C; Jefferson, Angela L; Gifford, Katherine A; Hohman, Timothy J; Nation, Daniel A; Delano-Wood, Lisa; Jak, Amy; Bangen, Katherine J; Bondi, Mark W; Brickman, Adam M; Manly, Jennifer; Swenson, Rodney; Au, Rhoda

    2018-01-01

    Working memory (WM) is often assessed with serial order tests such as repeating digits backward. In prior dementia research using the Backward Digit Span Test (BDT), only aggregate test performance was examined. The current research tallied primacy/recency effects, out-of-sequence transposition errors, perseverations, and omissions to assess WM deficits in patients with mild cognitive impairment (MCI). Memory clinic patients (n = 66) were classified into three groups: single domain amnestic MCI (aMCI), combined mixed domain/dysexecutive MCI (mixed/dys MCI), and non-MCI where patients did not meet criteria for MCI. Serial order/WM ability was assessed by asking participants to repeat 7 trials of five digits backwards. Serial order position accuracy, transposition errors, perseverations, and omission errors were tallied. A 3 (group)×5 (serial position) repeated measures ANOVA yielded a significant group×trial interaction. Follow-up analyses found attenuation of the recency effect for mixed/dys MCI patients. Mixed/dys MCI patients scored lower than non-MCI patients for serial position 3 (p Mixed/dys MCI patients also produced more transposition errors than both groups (p order parameters obtained from the BDT may provide a useful operational definition as well as additional diagnostic information regarding working memory deficits in MCI.

  1. The challenging image-guided abdominal mass biopsy: established and emerging techniques 'if you can see it, you can biopsy it'.

    Science.gov (United States)

    Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G

    2013-08-01

    Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.

  2. Clinical significance of inadequate endometrial biopsies prior to hysterectomy.

    Science.gov (United States)

    Turney, Emily H; Farghaly, Hanan; Eskew, Ashley M; Parker, Lynn P; Milam, Michael R

    2012-01-01

    To evaluate preoperative clinical risk factors associated with significant uterine histopathologic abnormalities in final hysterectomy specimens in patients with inadequate preoperative endometrial biopsies. This is an institutional review board-approved, retrospective cohort analysis of 469 consecutive patients who underwent preoperative endometrial biopsies with subsequent hysterectomy from January 1, 2005, to December 31, 2009, at the University of Louisville Medical Center. We analyzed risk factors for inadequate biopsy and for final diagnosis of endometrial pathology (defined as endometrial hyperplasia or uterine cancer). Of the 469 preoperative endometrial biopsies reviewed, 26.2% (123/469) were inadequate (IBx) and 73.8% (346/469) were adequate and benign. IBx on endometrial biopsies was associated with a greater risk of having significant uterine histopathologic abnormalities on final hysterectomy specimens (6.5% vs. 2.3%, RR 2.8 [95% CI 1.1-7.3], p = 0.04). Although inadequate endometrial biopsies are a common finding, they can be associated with significant uterine histopathologic abnormalities on final hysterectomy specimens.

  3. [Determination of the 120-day post prostatic biopsy mortality rate].

    Science.gov (United States)

    Canat, G A; Duclos, A; Couray-Targe, S; Schott, A-M; Polazzi, S; Scoazec, J-Y; Berger, F; Perrin, P

    2014-06-01

    Concerning death-rates were reported following prostate biopsy but the lack of contexts in which event occurred makes it difficult to take any position. Therefore, we aimed to determine the 120-day post-biopsy mortality rate. Between 2000 and 2011, 8804 men underwent prostate biopsy in the hospice civils de Lyon. We studied retrospectively, the mortality rate after each of the 11,816 procedures. Biopsies imputability was assessed by examining all medical records. Dates of death were extracted from our local patient management database, which is updated trimestrially with death notifications from the French National Institute for Statistics and Economic Studies. In our study 42 deaths occurred within 120days after 11,816 prostate biopsies (0.36%). Of the 42 records: 9 were lost to follow-up, 3 had no identifiable cause of death, 28 had an intercurrent event ruling out prostate biopsy as a cause of death. Only 2 deaths could be linked to biopsy. We reported at most 2 deaths possibly related to prostate biopsy over 11,816 procedures (0.02%). We confirmed the fact that prostate biopsies can be lethal but this rare outcome should not be considered as an argument against prostate screening given the circumstances in which it occurs. 5. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  4. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    International Nuclear Information System (INIS)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra; Muche, Rainer; Krueger, Stefan

    2008-01-01

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  5. CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track

    Energy Technology Data Exchange (ETDEWEB)

    Billich, Christian; Brenner, Gerhard; Schmidt, Stefan A.; Brambs, Hans-Juergen; Pauls, Sandra [University of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Muche, Rainer [University of Ulm, Institute of Biometrics, Ulm (Germany); Krueger, Stefan [University of Ulm, Department of Internal Medicine, Ulm (Germany)

    2008-06-15

    This study was conducted to evaluate whether instillation of NaCl 0.9% solution into the biopsy track reduces the incidence of pneumothoraces after CT-guided lung biopsy. A total of 140 consecutive patients with pulmonary lesions were included in this prospective study. All patients were alternatingly assigned to one of two groups: group A in whom the puncture access was sealed by instillation of NaCl 0.9% solution during extraction of the guide needle (n = 70) or group B for whom no sealing was performed (n = 70). CT-guided biopsy was performed with a 18-G coaxial system. Localization of lesion (pleural, peripheral, central), lesion size, needle-pleural angle, rate of pneumothorax and alveolar hemorrhage were evaluated. In group A, the incidence of pneumothorax was lower compared to group B (8%, 6/70 patients vs. 34%, 24/70 patients; P < 0.001). All pneumothoraces occurred directly post punctionem after extraction of the guide needle. One patient in group A and eight patients in group B developed large pneumothoraces requiring chest tube placement (P = 0.01). The frequency of pneumothorax was independent of other variables. After CT-guided biopsy, instillation of NaCl 0.9% solution into the puncture access during extraction of the needle significantly reduces the incidence of pneumothorax. (orig.)

  6. A serial-kinematic nanopositioner for high-speed atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wadikhaye, Sachin P., E-mail: sachin.wadikhaye@uon.edu.au; Yong, Yuen Kuan; Reza Moheimani, S. O. [School of Electrical Engineering and Computer Science, The University of Newcastle, Callaghan, NSW (Australia)

    2014-10-15

    A flexure-guided serial-kinematic XYZ nanopositioner for high-speed Atomic Force Microscopy is presented in this paper. Two aspects influencing the performance of serial-kinematic nanopositioners are studied in this work. First, mass reduction by using tapered flexures is proposed to increased the natural frequency of the nanopositioner. 25% increase in the natural frequency is achieved due to reduced mass with tapered flexures. Second, a study of possible sensor positioning in a serial-kinematic nanopositioner is presented. An arrangement of sensors for exact estimation of cross-coupling is incorporated in the proposed design. A feedforward control strategy based on phaser approach is presented to mitigate the dynamics and nonlinearity in the system. Limitations in design approach and control strategy are discussed in the Conclusion.

  7. A serial-kinematic nanopositioner for high-speed atomic force microscopy

    International Nuclear Information System (INIS)

    Wadikhaye, Sachin P.; Yong, Yuen Kuan; Reza Moheimani, S. O.

    2014-01-01

    A flexure-guided serial-kinematic XYZ nanopositioner for high-speed Atomic Force Microscopy is presented in this paper. Two aspects influencing the performance of serial-kinematic nanopositioners are studied in this work. First, mass reduction by using tapered flexures is proposed to increased the natural frequency of the nanopositioner. 25% increase in the natural frequency is achieved due to reduced mass with tapered flexures. Second, a study of possible sensor positioning in a serial-kinematic nanopositioner is presented. An arrangement of sensors for exact estimation of cross-coupling is incorporated in the proposed design. A feedforward control strategy based on phaser approach is presented to mitigate the dynamics and nonlinearity in the system. Limitations in design approach and control strategy are discussed in the Conclusion

  8. Histopathologic Review of Previously Negative Prostatic Core Needle Biopsies following a New Diagnosis of Adenocarcinoma of the Prostate by Core Needle Biopsies: Implications for Quality Assurance Programs

    Directory of Open Access Journals (Sweden)

    Jay Patel

    2008-01-01

    Full Text Available Programs for quality assurance are increasingly important in surgical pathology. Many quality assurance (QA techniques for surgical pathology were adopted from procedures introduced in cytopathology. Surgical pathology specimens have diminished in size such that the majority of diagnostic biopsies of prostatic lesions are now core needle biopsies. These specimens raise issues similar to those of cytology specimens, including concerns regarding adequacy and the representative nature of the biopsy. Due to sample size, some neoplasms may not be diagnosed on initial biopsy, raising concerns regarding false negative results. Cytopathologists have instituted QA procedures including review of all previously negative slides received within five years prior to the new diagnosis of high grade squamous intraepithelial lesion or gynecologic malignancy. No such requirement exists in surgical pathology for review of core biopsies. The Department of Pathology at the University of Utah instituted a QA policy requiring review of prior negative prostatic needle biopsies following a new diagnosis of prostatic adenocarcinoma. We reviewed five years of QA records of prostate needle biopsy review. During this time, nine hundred and fifty-eight core biopsy sets were performed. Two hundred and ninety-five of these contained at least one biopsy with a diagnosis of adenocarcinoma. Two hundred and eight patients had a prior set of prostatic needle biopsies with a diagnosis of adenocarcinoma. The remaining 87 had prior biopsies with either a diagnosis of prostatic intraepithelial neoplasia (23, small atypical acinar proliferation (21 or no evidence of malignancy (43. QA review of these 87 cases revealed two biopsies which revealed foci of adenocarcinoma. Both had been initially diagnosed as no evidence of malignancy. The false negative rate for core biopsy was 0.68%. In an additional twenty-one cases, microscopic foci of atypical small acinar proliferations were found in

  9. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Heerink, W.J.; Vliegenthart, R. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Bock, G.H. de [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Epidemiology, University of Groningen, Groningen (Netherlands); Jonge, G.J. de [University Medical Center Groningen, Department of Radiology, University of Groningen, Groningen (Netherlands); Groen, H.J.M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands); University Medical Center Groningen, Department of Pulmonary Medicine, University of Groningen, Groningen (Netherlands); Oudkerk, M. [University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, University of Groningen, Groningen (Netherlands)

    2017-01-15

    To meta-analyze complication rate in computed tomography (CT)-guided transthoracic lung biopsy and associated risk factors. Four databases were searched from 1/2000 to 8/2015 for studies reporting complications in CT-guided lung biopsy. Overall and major complication rates were pooled and compared between core biopsy and fine needle aspiration (FNA) using the random-effects model. Risk factors for complications in core biopsy and FNA were identified in meta-regression analysis. For core biopsy, 32 articles (8,133 procedures) were included and for FNA, 17 (4,620 procedures). Pooled overall complication rates for core biopsy and FNA were 38.8 % (95 % CI: 34.3-43.5 %) and 24.0 % (95 % CI: 18.2-30.8 %), respectively. Major complication rates were 5.7 % (95 % CI: 4.4-7.4 %) and 4.4 % (95 % CI: 2.7-7.0 %), respectively. Overall complication rate was higher for core biopsy compared to FNA (p < 0.001). For FNA, larger needle diameter was a risk factor for overall complications, and increased traversed lung parenchyma and smaller lesion size were risk factors for major complications. For core biopsy, no significant risk factors were identified. In CT-guided lung biopsy, minor complications were common and occurred more often in core biopsy than FNA. Major complication rate was low. For FNA, smaller nodule diameter, larger needle diameter and increased traversed lung parenchyma were risk factors for complications. (orig.)

  10. Does the use of the 2009 FIGO classification of endometrial cancer impact on indications of the sentinel node biopsy?

    Directory of Open Access Journals (Sweden)

    Ballester Marcos

    2010-08-01

    Full Text Available Abstract Background Lymphadenectomy is debated in early stages endometrial cancer. Moreover, a new FIGO classification of endometrial cancer, merging stages IA and IB has been recently published. Therefore, the aims of the present study was to evaluate the relevance of the sentinel node (SN procedure in women with endometrial cancer and to discuss whether the use of the 2009 FIGO classification could modify the indications for SN procedure. Methods Eighty-five patients with endometrial cancer underwent the SN procedure followed by pelvic lymphadenectomy. SNs were detected with a dual or single labelling method in 74 and 11 cases, respectively. All SNs were analysed by both H&E staining and immunohistochemistry. Presumed stage before surgery was assessed for all patients based on MR imaging features using the 1988 FIGO classification and the 2009 FIGO classification. Results An SN was detected in 88.2% of cases (75/85 women. Among the fourteen patients with lymph node metastases one-half were detected by serial sectioning and immunohistochemical analysis. There were no false negative case. Using the 1988 FIGO classification and the 2009 FIGO classification, the correlation between preoperative MRI staging and final histology was moderate with Kappa = 0.24 and Kappa = 0.45, respectively. None of the patients with grade 1 endometrioid carcinoma on biopsy and IA 2009 FIGO stage on MR imaging exhibited positive SN. In patients with grade 2-3 endometrioid carcinoma and stage IA on MR imaging, the rate of positive SN reached 16.6% with an incidence of micrometastases of 50%. Conclusions The present study suggests that sentinel node biopsy is an adequate technique to evaluate lymph node status. The use of the 2009 FIGO classification increases the accuracy of MR imaging to stage patients with early stages of endometrial cancer and contributes to clarify the indication of SN biopsy according to tumour grade and histological type.

  11. Does the use of the 2009 FIGO classification of endometrial cancer impact on indications of the sentinel node biopsy?

    International Nuclear Information System (INIS)

    Ballester, Marcos; Koskas, Martin; Coutant, Charles; Chéreau, Elisabeth; Seror, Jeremy; Rouzier, Roman; Daraï, Emile

    2010-01-01

    Lymphadenectomy is debated in early stages endometrial cancer. Moreover, a new FIGO classification of endometrial cancer, merging stages IA and IB has been recently published. Therefore, the aims of the present study was to evaluate the relevance of the sentinel node (SN) procedure in women with endometrial cancer and to discuss whether the use of the 2009 FIGO classification could modify the indications for SN procedure. Eighty-five patients with endometrial cancer underwent the SN procedure followed by pelvic lymphadenectomy. SNs were detected with a dual or single labelling method in 74 and 11 cases, respectively. All SNs were analysed by both H&E staining and immunohistochemistry. Presumed stage before surgery was assessed for all patients based on MR imaging features using the 1988 FIGO classification and the 2009 FIGO classification. An SN was detected in 88.2% of cases (75/85 women). Among the fourteen patients with lymph node metastases one-half were detected by serial sectioning and immunohistochemical analysis. There were no false negative case. Using the 1988 FIGO classification and the 2009 FIGO classification, the correlation between preoperative MRI staging and final histology was moderate with Kappa = 0.24 and Kappa = 0.45, respectively. None of the patients with grade 1 endometrioid carcinoma on biopsy and IA 2009 FIGO stage on MR imaging exhibited positive SN. In patients with grade 2-3 endometrioid carcinoma and stage IA on MR imaging, the rate of positive SN reached 16.6% with an incidence of micrometastases of 50%. The present study suggests that sentinel node biopsy is an adequate technique to evaluate lymph node status. The use of the 2009 FIGO classification increases the accuracy of MR imaging to stage patients with early stages of endometrial cancer and contributes to clarify the indication of SN biopsy according to tumour grade and histological type

  12. Serial Millisecond Crystallography of Membrane Proteins.

    Science.gov (United States)

    Jaeger, Kathrin; Dworkowski, Florian; Nogly, Przemyslaw; Milne, Christopher; Wang, Meitian; Standfuss, Joerg

    2016-01-01

    Serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) is a powerful method to determine high-resolution structures of pharmaceutically relevant membrane proteins. Recently, the technology has been adapted to carry out serial millisecond crystallography (SMX) at synchrotron sources, where beamtime is more abundant. In an injector-based approach, crystals grown in lipidic cubic phase (LCP) or embedded in viscous medium are delivered directly into the unattenuated beam of a microfocus beamline. Pilot experiments show the application of microjet-based SMX for solving the structure of a membrane protein and compatibility of the method with de novo phasing. Planned synchrotron upgrades, faster detectors and software developments will go hand-in-hand with developments at free-electron lasers to provide a powerful methodology for solving structures from microcrystals at room temperature, ligand screening or crystal optimization for time-resolved studies with minimal or no radiation damage.

  13. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  14. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  15. Serial-position effects on a free-recall task in bilinguals.

    Science.gov (United States)

    Yoo, Jeewon; Kaushanskaya, Margarita

    2016-01-01

    In this study, we examined mechanisms that underlie free-recall performance in bilinguals' first language (L1) and second language (L2) through the prism of serial-position effects. On free-recall tasks, a typical pattern of performance follows a U-shaped serial-position curve, where items from the beginning of the list (the primacy effect) and items from the end of the list (the recency effect) are recalled with higher accuracy than items from the middle of the list. The present study contrasted serial-position effects on the free-recall task in Korean-English bilinguals' L1 vs. L2 and examined the relationship between an independent working memory (WM) measure and serial-position effects in bilinguals' two languages. Results revealed stronger pre-recency (primacy and middle) effects in L1 than in L2, but similar recency effects in the two languages. A close association was observed between WM and recall performance in the pre-recency region in the L1 but not in the L2. Together, these findings suggest that linguistic knowledge constrains free-recall performance in bilinguals, but only in the pre-recency region.

  16. 11C-L-methyl methionine dynamic PET/CT of skeletal muscle: response to protein supplementation compared to L-[ring 13C6] phenylalanine infusion with serial muscle biopsy.

    Science.gov (United States)

    Arentson-Lantz, Emily J; Saeed, Isra H; Frassetto, Lynda A; Masharani, Umesh; Harnish, Roy J; Seo, Youngho; VanBrocklin, Henry F; Hawkins, Randall A; Mari-Aparici, Carina; Pampaloni, Miguel H; Slater, James; Paddon-Jones, Douglas; Lang, Thomas F

    2017-05-01

    The objective of this study was to determine if clinical dynamic PET/CT imaging with 11 C-L-methyl-methionine ( 11 C-MET) in healthy older women can provide an estimate of tissue-level post-absorptive and post-prandial skeletal muscle protein synthesis that is consistent with the more traditional method of calculating fractional synthesis rate (FSR) of muscle protein synthesis from skeletal muscle biopsies obtained during an infusion of L-[ring 13 C 6 ] phenylalanine ( 13 C 6 -Phe). Healthy older women (73 ± 5 years) completed both dynamic PET/CT imaging with 11 C-MET and a stable isotope infusion of 13 C 6 -Phe with biopsies to measure the skeletal muscle protein synthetic response to 25 g of a whey protein supplement. Graphical estimation of the Patlak coefficient K i from analysis of the dynamic PET/CT images was employed as a measure of incorporation of 11 C-MET in the mid-thigh muscle bundle. Post-prandial values [mean ± standard error of the mean (SEM)] were higher than post-absorptive values for both K i (0.0095 ± 0.001 vs. 0.00785 ± 0.001 min -1 , p Dynamic PET/CT imaging with 11 C-MET provides an estimate of the post-prandial anabolic response that is consistent with a traditional, invasive stable isotope, and muscle biopsy approach. These results support the potential future use of 11 C-MET imaging as a non-invasive method for assessing conditions affecting skeletal muscle protein synthesis.

  17. A study on the utilization of serial resources in selected tertiary ...

    African Journals Online (AJOL)

    A study on the utilization of serial resources in selected tertiary institutions in Ogun State. ... Lagos Journal of Library and Information Science ... Serial resources are publications either in printed form or electronic format issued in successive parts usually having numerical or chronological designations and intended to be ...

  18. Epidemiology of biopsy-proven glomerulonephritis in Queensland adults.

    Science.gov (United States)

    Jegatheesan, Dev; Nath, Karthik; Reyaldeen, Reza; Sivasuthan, Goutham; John, George T; Francis, Leo; Rajmokan, Mohana; Ranganathan, Dwarakanathan

    2016-01-01

    There is a paucity of data pertaining to the incidence of biopsy-proven glomerulonephritis (GN) in Australia. This retrospective study aims to review the data from all adult native renal biopsies performed in the state of Queensland from 2002 to 2011--comparing results with centres from across the world. Pathology reports of 3697 adult native kidney biopsies were reviewed, of which 2048 had GN diagnoses. Age, gender, clinical indication and histopathology findings were compared. The average age at biopsy was 48 ± 17 years. Male preponderance was noted overall (∼60%), with lupus nephritis being the only individual GN with female predilection. The average rate of biopsy was 12.04 per hundred thousand people per year (php/yr). Nephrotic and nephritic syndromes comprised approximately 75% of all clinical indications that lead to GN diagnoses. IgA nephropathy (1.41 php/yr) was the most common primary GN followed by focal segmental glomerulosclerosis (1.02 php/yr) and crescentic GN (0.73 php/yr). Diabetic nephropathy (0.84 php/yr), lupus nephritis (0.69 php/yr) and amyloidosis (0.19 php/yr) were the most commonly identified secondary GN. IgA nephropathy is the predominant primary GN in Queensland, and nephrotic syndrome the most common indication for a renal biopsy. While crescentic GN incidence has significantly increased with time, focal segmental glomerulosclerosis incidence has not shown any trend. Incidence of GN overall appears to increase with age. The annual rate of biopsy in this study appears lower than previously published in an Australian population. © 2015 Asian Pacific Society of Nephrology.

  19. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  20. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  1. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  2. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  3. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun-Kyung; Park, Sun Young; Jung, Hae Kyoung; Park, Byeong-Woo; Kim, Haeryung; Oh, Ki Keun

    2008-01-01

    Objective: To determine the frequency of imaging-histologic discordance at percutaneous breast biopsy and to evaluate differences in clinical and radiologic findings between pathologically upgraded lesions and non-upgraded lesions. Materials and methods: From February 2000 to June 2005, we reviewed 386 cases that had suspicious imaging findings but yielded benign histology at US-core needle biopsy and that underwent subsequent excisional biopsy. In 74 of 386 cases, the benign histology at core needle biopsy could not provide a satisfactory explanation for the radiologically suspicious lesions. The clinical, radiologic and histologic findings were reviewed for those 74 cases that were classified as the upgrade group and the non-upgrade group after excisional biopsy. Results: The upgrade rate was 17.6% (95% confidence interval, 10.6-27.8%, 13 of 74 cases) revealed upgraded pathology at the subsequent excisional biopsy. Besides the size of masses, there were no statistically significant differences in imaging findings between the upgrade and non-upgrade groups at excisional biopsy. Conclusion: This upgrade rate of 17.6% suggests that excisional biopsy or re-biopsy is warranted in those cases presenting imaging-histologic discordance at US-guided core biopsy

  4. Benign core biopsy of probably benign breast lesions 2 cm or larger: correlation with excisional biopsy and long-term follow-up

    International Nuclear Information System (INIS)

    Jung, Hyun Kyung; Moon, Hee Jung; Kim, Min Jung; Kim, Eun Kyung

    2014-01-01

    To evaluate the accuracy of benign core biopsy of probably benign breast lesions (category 3) 2 cm or larger on the basis of excisional biopsy and long-term follow-up. We retrospectively reviewed 146 category 3 lesions in 146 patients 2 cm or larger which were diagnosed as benign by ultrasound (US)-guided core biopsy. Patients were initially diagnosed as benign at core needle biopsy and then followed up with excisional biopsy (surgical excision, n=91; US-guided vacuum assisted excision, n=35) or breast ultrasonography (n=20). Of the 126 patients who underwent surgical excision or US-guided vacuum-assisted excision, 114 patients were diagnosed with benign lesions, 10 patients with borderline lesions (benign phyllodes tumor), and two patients with malignant phyllodes tumors. The probabilities of lesions being benign, borderline and malignant were 91.8% (134/146), 6.8% (10/146), and 1.4% (2/146), respectively. Of 13 patients who had growing masses on follow-up ultrasonography, three (23.1%) were non-benign (two benign phyllodes tumors and one malignant phyllodes tumor). US-guided core needle biopsy of probably benign breast mass 2 cm or larger was accurate (98.6%) enough to rule out malignancy. But, it was difficult to rule out borderline lesions even when they were diagnosed as benign.

  5. MR-guided biopsies of undetermined liver lesions: technique and results; MRT-gezielte perkutane Biopsie bei unklaren fokalen Leberlaesionen: Technik und Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Zangos, S.; Kiefl, D.; Eichler, K.; Engelmann, K.; Heller, M.; Herzog, C.; Mack, M.G.; Jacobi, V.; Vogl, T.J. [Inst. fuer Diagnostische und Interventionelle Radiologie, Johann-Wolfgang-Goethe-Univ. Frankfurt (Germany)

    2003-05-01

    Purpose: To evaluate safety and precision of liver tumor biopsies performed in an open low field system using different sequence techniques. Materials and Methods: In 47 patients with liver tumors, MR-guided biopsies were performed in a low field system (0.2 Tesla, Magnetom Open, Siemens) using two different sequences. The procedure was monitored with T1-weighted FLASH sequences (TR/TE = 100/9; 70 ) in all patients and with FISP-Rotated-Keyhole-sequence (TR/TE = 18/8; 90 ) in additional 20 patients. After positioning of the needle tip in the tumors, 166 biopsy specimens were acquired with 16 G cutting needles (Somatex{sup *}). The diameter of the biopsied lesions ranged from 1 to 10 cm (mean diameter 3.2 cm). Visibility of the needles and precision of the biopsies were evaluated. Results: All interventional biopsies were performed without vascular or organ injuries. Adequate specimens for histologic interpretation were obtained in 42 cases (89.3%). The biopsy results were non-specific in 2 patients (4.2%) and the lesions missed in 3 patients (6.3%). Mean in-room time was 35 minutes and the intervention time was 8.3 minutes. T1-weighted FLASH images proved optimal for confirming needle-tip placement during the biopsies or punctures. Organs, tumors and vessels were easily identified. The FISP sequence proved to be inferior in visualizing vessels and tumors. Conclusion: MR-guided liver biopsies are safely and precisely performed using T1-weighted FLASH-sequences with sufficient visualization of the lesions and might be complementary to US- or CT-guided biopsies. (orig.) [German] Zielsetzung: Evaluierung der Sicherheit und Genauigkeit MRT-gezielter Leberbiopsien unter Verwendung verschiedener Sequenzen. Methoden: Bei 47 Patienten mit unklaren Leberlaesionen wurden in einem offenen 0,2-Tesla-MR-System (Magnetom Open, Siemens) bildgesteuerte Biopsien unter Verwendung von zwei verschiedenen Sequenzen durchgefuehrt. Die Bildgebung erfolgte bei allen Patienten mittels T

  6. Pleural biopsy for indeterminate cases of pleural effusion | Ukadike ...

    African Journals Online (AJOL)

    Materials and Methods: This is a retrospective study of all consecutive cases of pleural biopsies done for indeterminate cause of pleural effusion in the University of Benin Teaching Hospital from December 2008 to May 2010, a total of 18months. Blind pleural biopsy was carried out using the Abram's Pleural Biopsy Needle.

  7. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  8. Microfibrillar cardiomyopathy: A rare case

    Directory of Open Access Journals (Sweden)

    Narender Kumar

    2011-01-01

    Full Text Available Microfibrillar cardiomyopathy is a very rare cause of restrictive cardiomyopathy (RCM. The index case was a male patient who presented with shortness of breath and pedal edema. Further clinical investigations favored a clinical diagnosis of RCM. An endomyocardial biopsy revealed subendocardial and interstitial hyaline eosinophillic material resembling amyloid that did not stain with Congo red. An electron microscopic examination showed that this material was composed of twisted linear and bundles of tangled microfibrils. The etiology of the microfibrillar deposition is currently unknown. The pathologists should entertain the diagnosis of microfibrillar cardiomyopathy in suspected cases of amyloidosis that are negative for Congo red.

  9. Subject-Verb Agreement in Children and Adults: Serial or Hierarchical Processing?

    Science.gov (United States)

    Negro, Isabelle; Chanquoy, Lucile; Fayol, Michel; Louis-Sidney, Maryse

    2005-01-01

    Two processes, serial and hierarchical, are generally opposed to account for grammatical encoding in language production. In a developmental perspective, the question addressed here is whether the subject-verb agreement during writing is computed serially, once the words are linearly ordered in the sentence, or hierarchically, as soon as the…

  10. Serial Position Effects in the Identification of Letters, Digits, and Symbols

    Science.gov (United States)

    Tydgat, Ilse; Grainger, Jonathan

    2009-01-01

    In 6 experiments, the authors investigated the form of serial position functions for identification of letters, digits, and symbols presented in strings. The results replicated findings obtained with the target search paradigm, showing an interaction between the effects of serial position and type of stimulus, with symbols generating a distinct…

  11. Efficient multitasking: parallel versus serial processing of multiple tasks.

    Science.gov (United States)

    Fischer, Rico; Plessow, Franziska

    2015-01-01

    In the context of performance optimizations in multitasking, a central debate has unfolded in multitasking research around whether cognitive processes related to different tasks proceed only sequentially (one at a time), or can operate in parallel (simultaneously). This review features a discussion of theoretical considerations and empirical evidence regarding parallel versus serial task processing in multitasking. In addition, we highlight how methodological differences and theoretical conceptions determine the extent to which parallel processing in multitasking can be detected, to guide their employment in future research. Parallel and serial processing of multiple tasks are not mutually exclusive. Therefore, questions focusing exclusively on either task-processing mode are too simplified. We review empirical evidence and demonstrate that shifting between more parallel and more serial task processing critically depends on the conditions under which multiple tasks are performed. We conclude that efficient multitasking is reflected by the ability of individuals to adjust multitasking performance to environmental demands by flexibly shifting between different processing strategies of multiple task-component scheduling.

  12. The neural signature of emotional memories in serial crimes.

    Science.gov (United States)

    Chassy, Philippe

    2017-10-01

    Neural plasticity is the process whereby semantic information and emotional responses are stored in neural networks. It is hypothesized that the neural networks built over time to encode the sexual fantasies that motivate serial killers to act should display a unique, detectable activation pattern. The pathological neural watermark hypothesis posits that such networks comprise activation of brain sites that reflect four cognitive components: autobiographical memory, sexual arousal, aggression, and control over aggression. The neural sites performing these cognitive functions have been successfully identified by previous research. The key findings are reviewed to hypothesise the typical pattern of activity that serial killers should display. Through the integration of biological findings into one framework, the neural approach proposed in this paper is in stark contrast with the many theories accounting for serial killers that offer non-medical taxonomies. The pathological neural watermark hypothesis offers a new framework to understand and detect deviant individuals. The technical and legal issues are briefly discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Prostate atypia: does repeat biopsy detect clinically significant prostate cancer?

    Science.gov (United States)

    Dorin, Ryan P; Wiener, Scott; Harris, Cory D; Wagner, Joseph R

    2015-05-01

    While the treatment pathway in response to benign or malignant prostate biopsies is well established, there is uncertainty regarding the risk of subsequently diagnosing prostate cancer when an initial diagnosis of prostate atypia is made. As such, we investigated the likelihood of a repeat biopsy diagnosing prostate cancer (PCa) in patients in which an initial biopsy diagnosed prostate atypia. We reviewed our prospectively maintained prostate biopsy database to identify patients who underwent a repeat prostate biopsy within one year of atypia (atypical small acinar proliferation; ASAP) diagnosis between November 1987 and March 2011. Patients with a history of PCa were excluded. Chart review identified patients who underwent radical prostatectomy (RP), radiotherapy (RT), or active surveillance (AS). For some analyses, patients were divided into two subgroups based on their date of service. Ten thousand seven hundred and twenty patients underwent 13,595 biopsies during November 1987-March 2011. Five hundred and sixty seven patients (5.3%) had ASAP on initial biopsy, and 287 (50.1%) of these patients underwent a repeat biopsy within one year. Of these, 122 (42.5%) were negative, 44 (15.3%) had atypia, 19 (6.6%) had prostatic intraepithelial neoplasia, and 102 (35.6%) contained PCa. Using modified Epstein's criteria, 27/53 (51%) patients with PCa on repeat biopsy were determined to have clinically significant tumors. 37 (36.3%) proceeded to RP, 25 (24.5%) underwent RT, and 40 (39.2%) received no immediate treatment. In patients who underwent surgery, Gleason grade on final pathology was upgraded in 11 (35.5%), and downgraded 1 (3.2%) patient. ASAP on initial biopsy was associated with a significant risk of PCa on repeat biopsy in patients who subsequently underwent definitive local therapy. Patients with ASAP should be counseled on the probability of harboring both clinically significant and insignificant prostate cancer. © 2015 Wiley Periodicals, Inc.

  14. Repeated biopsies in prostate cancer patients on active surveillance

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebaek; Marcussen, Niels; Berg, Kasper Drimer

    2015-01-01

    OBJECTIVE: To investigate the clinical implications of interobserver variation in the assessment of re-biopsies obtained during active surveillance (AS). MATERIAL AND METHODS: A total of 107 low-risk prostate cancer patients with a total of 93 diagnostic biopsy sets and 109 re-biopsy sets were...... included. The ISUP 2005 Gleason scoring system was applied for the histopathological assessment of all biopsies. Three different definitions of histopathological progression were applied. Unweighted and linear weighted Kappa statistics were used to compare the interobserver agreement. RESULTS: The overall...... recommendations would have changed in up to 10.1% (95% CI: 5.4%-17.7%) of the 109 re-biopsy sets. CONCLUSION: Kappa statistics demonstrated a strong agreement between the histological evaluations. Still, up to 10% of AS patients would receive different treatment recommendation depending upon which...

  15. Transrectal ultrasound: Diagnosis of prostate cancer by a new biplane US-guided biopsy technique. Comparison of thin-needle cytology and histology with large-core biopsy

    International Nuclear Information System (INIS)

    Lee, F.; Littrup, P.; McLeary, R.; Kumasaka, G.; Borlaza, G.; McHugh, T.; Soiderer, M.; Roi, L.

    1986-01-01

    A new transperineal biopsy technique was developed that uses biplane transrectal US guidance for needle placement into anechoic-hypoechoic lesions thought to indicate prostate cancer (n = 83). The results of histologic studies on biopsy material obtained with a 22-gauge needle and of aspiration histologic studies on biopsy material obtained with a 19-gauge needle were compared with results of histologic studies on material obtained with a 14-gauge needle. When sufficient tissue was obtained, the positive biopsy yield was 61% by cytology and 58% by histology; the combined yield was 61%. A limited study ( n = 21) of histologic findings in biopsy material obtained with 19-gauge and 14-gauge needles showed equivalent diagnostic results. Sixty-seven percent of the biopsies were of lesions less than 1.5 cm in diameter, and 57% (13 of 23) of the biopsy-proved cancers in this group were either nonpalpable or only mildly suspicious on digital rectal examination

  16. [Hospitalization rate in relation to severe complications of transrectal prostate biopsy: About 2715 patients biopsied].

    Science.gov (United States)

    Tamarelle, B; Perrin, P; Devonec, M; Paparel, P; Ruffion, A

    To identify hospitalizations directly related to a complication occurring within 30 days following a transrectal prostate biopsy (PBP). Overall hospitalization rates, mortality rates, potential predisposing factors for complications. Single-center study including all patients who underwent PBP between January 2005 and January 2012. Any hospitalization occurring within 30 days of the PBP for urgent motive was considered potentially attributable to biopsy. We identified the reason for hospitalization with direct complications (urinary infection or fever, rectal bleeding, bladder caillotage, retention) and indirect (underlying comorbidities decompensation) of the biopsy. The contributing factors were anticoagulant or antiplatelet treatment well as waning immunity factors (corticosteroid therapy, HIV, chemotherapy or immunodulateur). Among 2715 men who underwent PBP, there were 120 (4.4%) hospitalizations including 28 (1.03%) caused by the biopsy. Twenty-five (0.92%) were related to a direct complication of biopsy: 14 (56%) for urinary tract infection or fever including 1 hospitalization in intensive care, 5 (20%) for rectal bleeding which required several transfusions 1, 10 (40%) urinary retention and 3 (0.11%) for an indirect complication (2 coronary syndromes and 1 respiratory failure). Several direct complications were associated in 3 cases. Only two hospitalizations associated with rectal bleeding were taking an antiplatelet or anticoagulant. There was no association between hospitalization for urinary tract infections and a decreased immune status. The first death observed in our study occurred at D31 of pulmonary embolism (advanced metastatic patient with bladder cancer). Twenty (60.6%) patients urgently hospitalized did not have prostate cancer. Within this large sample of patients the overall rate of hospitalization due to the realization of a PBP was 1%. It has not been found predictive of complications leading to hospitalization. 4. Copyright © 2016

  17. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  18. Changing Series: Narrative Models and the Role of the Viewer in Contemporary Television Seriality

    Directory of Open Access Journals (Sweden)

    Veronica Innocenti

    2015-04-01

    Full Text Available In the past few years television serial narratives have gone through some severe changes in the way they are organized from a narrative point of view, as well as in the way they are perceived by the audiences. Our article originates from the necessity of investigating the products of this new wave of serial production, with the purpose of focusing on narrative formulas and on the relationships that serial products establish with their users. Vast serialized narratives are not just texts anymore, they have become complex universes of meaning that last for long time and that have a strong influence on the audiences. The article aims to investigate serial narratives as usable objects, that are not just seen by the public, but that are part of a complex experience.

  19. MRI/TRUS fusion software-based targeted biopsy: the new standard of care?

    Science.gov (United States)

    Manfredi, M; Costa Moretti, T B; Emberton, M; Villers, A; Valerio, M

    2015-09-01

    The advent of multiparametric MRI has made it possible to change the way in which prostate biopsy is done, allowing to direct biopsies to suspicious lesions rather than randomly. The subject of this review relates to a computer-assisted strategy, the MRI/US fusion software-based targeted biopsy, and to its performance compared to the other sampling methods. Different devices with different methods to register MR images to live TRUS are currently in use to allow software-based targeted biopsy. Main clinical indications of MRI/US fusion software-based targeted biopsy are re-biopsy in men with persistent suspicious of prostate cancer after first negative standard biopsy and the follow-up of patients under active surveillance. Some studies have compared MRI/US fusion software-based targeted versus standard biopsy. In men at risk with MRI-suspicious lesion, targeted biopsy consistently detects more men with clinically significant disease as compared to standard biopsy; some studies have also shown decreased detection of insignificant disease. Only two studies directly compared MRI/US fusion software-based targeted biopsy with MRI/US fusion visual targeted biopsy, and the diagnostic ability seems to be in favor of the software approach. To date, no study comparing software-based targeted biopsy against in-bore MRI biopsy is available. The new software-based targeted approach seems to have the characteristics to be added in the standard pathway for achieving accurate risk stratification. Once reproducibility and cost-effectiveness will be verified, the actual issue will be to determine whether MRI/TRUS fusion software-based targeted biopsy represents anadd-on test or a replacement to standard TRUS biopsy.

  20. Alcohol purchase age laws and the serial beginning drinker in New York.

    Science.gov (United States)

    Yu, J

    1995-08-01

    Raising the drinking age twice in New York State in the 1980s might have created a generation of "serial beginning drinkers." Findings indicate that when young adults become beginning drinkers, their chances of drinking-driving increase; when they become serial beginning drinkers, their involvement in drinking-driving remains high over time. The beginning drinkers belong to a special historical period and are only composed of birth cohorts of 3 or 4 years (mainly early 1960s). The effect of the serial beginning drinker should fade out as those birth cohorts grow into maturity.

  1. Ultraviolet-fluorescent tattoo location of cutaneous biopsy site.

    Science.gov (United States)

    Chuang, Gary S; Gilchrest, Barbara A

    2012-03-01

    Cutaneous biopsies often heal with little or no scarring. Prior studies have shown an alarming percentage of patients who incorrectly identify biopsy sites at the time of surgery. To investigate the safety and utility of an ultraviolet (UV)-fluorescent tattoo for biopsy site identification. A preclinical proof of concept was established with skin culture. An UV-fluorescent tattoo was applied to discarded neonatal foreskin in culture medium. The stability of the tattooed skin was examined clinically and histologically. One patient with a recurrent basal cell carcinoma in a difficult-to-identify location underwent tattoo application at the time of biopsy to demarcate the site. The patient was monitored for tattoo reaction and referred for surgical excision. The cultured tissue exhibited stable UV fluorescence with daily washing. Tissue histology demonstrated tattoo particles lining the skin edge under fluorescent microscopy. The patient was reluctant to undergo another surgical procedure and instead returned to our clinic at 3 months and 17 months after the biopsy for management of other tumors. The patient had no symptoms of allergic reaction to the tattoo dye. The fluorescent tattoo remains invisible under visible light and visible only under Wood's light. The present study documents the utility of an UV-fluorescent tattoo to locate a biopsy site. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  2. X-ray guided biopsy

    International Nuclear Information System (INIS)

    Casanova, R.; Lezana, A.H.; Pedrosa, C.S.

    1980-01-01

    Fine needle aspiration biopsy (FNAB) is now a routine procedure in many X-ray Departments. This paper presents the authors' experience with this technique in chest, abdominal and skeletal lesions. (Auth.)

  3. Synchronic Seriality: The Dissolving of Diegetic Borders Through Metalepsis

    Directory of Open Access Journals (Sweden)

    Paige M. Piper

    2015-12-01

    Full Text Available In dialogue with Gérard Genette’s literary concept of metalepsis to television, this paper considers instances of meta-textual actor/character portrayals in serial narratives to show that meta-narrative intrusion fosters a greater empathetic link between the spectator and character, whilst simultaneously inviting the viewer to appreciate the technique as an artifice-aware gesture. The fluidity of diegetic borders brought on by the conflation of performer/performance replicates Baudrillard’s simulacra, creating a synchronic form of seriality and transcending rigid genre classifications.

  4. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    Science.gov (United States)

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  5. Spatial serial order processing in schizophrenia.

    Science.gov (United States)

    Fraser, David; Park, Sohee; Clark, Gina; Yohanna, Daniel; Houk, James C

    2004-10-01

    The aim of this study was to examine serial order processing deficits in 21 schizophrenia patients and 16 age- and education-matched healthy controls. In a spatial serial order working memory task, one to four spatial targets were presented in a randomized sequence. Subjects were required to remember the locations and the order in which the targets were presented. Patients showed a marked deficit in ability to remember the sequences compared with controls. Increasing the number of targets within a sequence resulted in poorer memory performance for both control and schizophrenia subjects, but the effect was much more pronounced in the patients. Targets presented at the end of a long sequence were more vulnerable to memory error in schizophrenia patients. Performance deficits were not attributable to motor errors, but to errors in target choice. The results support the idea that the memory errors seen in schizophrenia patients may be due to saturating the working memory network at relatively low levels of memory load.

  6. Quick, sensitive serial NMR experiments with Radon transform.

    Science.gov (United States)

    Dass, Rupashree; Kasprzak, Paweł; Kazimierczuk, Krzysztof

    2017-09-01

    The Radon transform is a potentially powerful tool for processing the data from serial spectroscopic experiments. It makes it possible to decode the rate at which frequencies of spectral peaks shift under the effect of changing conditions, such as temperature, pH, or solvent. In this paper we show how it also improves speed and sensitivity, especially in multidimensional experiments. This is particularly important in the case of low-sensitivity techniques, such as NMR spectroscopy. As an example, we demonstrate how Radon transform processing allows serial measurements of 15 N-HSQC spectra of unlabelled peptides that would otherwise be infeasible. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Systemic Air Embolism After CT-guided Lung Biopsy

    Science.gov (United States)

    2017-11-27

    Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT

  8. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  9. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  10. Complications and risk factors in transrectal ultrasound-guided prostate biopsies

    Directory of Open Access Journals (Sweden)

    Carlos Márcio Nóbrega de Jesus

    Full Text Available CONTEXT AND OBJECTIVE: Prostate biopsy is not a procedure without risk. There is concern about major complications and which antibiotics are best for routine use before these biopsies. The objective was to determine the rate of complications and the possible risk factors in prostate biopsies. DESIGN AND SETTING: Prospective study, Faculdade de Medicina de Botucatu. METHODS: Transrectal ultrasound (TRUS guided prostate biopsies were carried out in 174 patients presenting either abnormality in digital rectal examinations (DRE or levels higher than 4 ng/ml in prostate-specific antigen (PSA tests, or both. RESULTS: Hemorrhagic complications were the most common (75.3%, while infectious complications occurred in 19% of the cases. Hematuria was the most frequent type (56%. Urinary tract infection (UTI occurred in 16 patients (9.2%. Sepsis was observed in three patients (1.7%. The presence of an indwelling catheter was a risk factor for infectious complications (p < 0.05. Higher numbers of biopsies correlated with hematuria, rectal bleeding and infectious complications (p < 0.05. The other conditions investigated did not correlate with post-biopsy complications. CONCLUSIONS: Post-biopsy complications were mostly self-limiting. The rate of major complications was low, thus showing that TRUS guided prostate biopsy was safe and effective. Higher numbers of fragments taken in biopsies correlated with hematuria, rectal bleeding and infectious complications. An indwelling catheter represented a risk factor for infectious complications. The use of aspirin was not an absolute contraindication for TRUS.

  11. Sono-Guided Percutaneous Automated Gun Biopsy in Pediatric Renal Disease

    International Nuclear Information System (INIS)

    Kim, Jong Chul

    1996-01-01

    To evaluate whether sono-guided percutaneous automated gun biopsy is also useful in pediatricpatients with renal diseases. In the prone position of twenty pediatric patients with renal parenchymal diseases, percutaneous biopsy was done through lateral aspect of the lower pole of left kidney with automated biopsy gun under the guidance of ultrasonography. The biopsy needle was either of 18 or 20 gauge. The obtained core of renal tissue was examined with light, immunofluorescent or electron microscope by the renal pathologist. In 18 among 20 patients, adequate renal tissue core sufficient to be pathologically diagnosed was obtained. The histologic findings were as follows : IG A nephropathy (n = 2), lupus nephritis (n =2), minimal change glomerulonephritis (n = 5), membranoproliferative glomerulonephritis (n = 3), mesangialproliferative glomeru-lonephritis (n = 1), diffuse proliferative glomerulonephritis (n = 3), focalglomerulo-sclerosis (n = 1), membranous glomerulopathy (n = 1). No significant complications occurred during or after the biopsy. Sono-guided percutaneous renal biopsy using automated biopsy gun is also useful todiagnose renal parenchymal diseases without significant complications in pediatric patients

  12. Breast Biopsy: The Effects of Hypnosis and Music.

    Science.gov (United States)

    Téllez, Arnoldo; Sánchez-Jáuregui, Teresa; Juárez-García, Dehisy M; García-Solís, Manuel

    2016-01-01

    The authors evaluated the efficacies of audio-recorded hypnosis with background music and music without hypnosis in the reduction of emotional and physical disturbances in patients scheduled for breast biopsy in comparison with a control group. A total of 75 patients were randomly assigned to 3 different groups and evaluated at baseline and before and after breast biopsy using visual analog scales of stress, pain, depression, anxiety, fatigue, optimism, and general well-being. The results showed that, before breast biopsy, the music group presented less stress and anxiety, whereas the hypnosis with music group presented reduced stress, anxiety, and depression and increased optimism and general well-being. After the biopsy, the music group presented less anxiety and pain, whereas the hypnosis group showed less anxiety and increased optimism.

  13. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  14. The diagnostic ability of an additional midline peripheral zone biopsy in transrectal ultrasonography-guided 12-core prostate biopsy to detect midline prostate cancer

    Directory of Open Access Journals (Sweden)

    Inpyeong Hwang

    2016-01-01

    Full Text Available Purpose: The goal of this study was to evaluate the diagnostic effect of adding a midline peripheral zone (PZ biopsy to the 12-core biopsy protocol used to diagnose prostate cancer (PC, and to assess the clinical and pathologic characteristics of midline-positive PC in order to identify a potential subgroup of patients who would require midline PZ biopsy. Methods: This study included 741 consecutive patients who underwent a transrectal ultrasonography-guided, 12-core prostate biopsy with an additional midline core biopsy between October 2012 and December 2013. We grouped patients by the presence or absence of PC and subdivided patients with PC based on the involvement of the midline core. The clinical characteristics of these groups were compared, including serum prostate-specific antigen (PSA concentrations, PSA density, and pathological features in the biopsy specimens. Results: PC was detected in 289 patients (39.0%. Among the PC patients, 66 patients (22.8% had midline PC. No patients were diagnosed with PC based only on a midline core. The Gleason scores, number of positive cores, tumor core length, serum PSA concentrations, and PSA density were significantly higher in patients with midline-positive PC (P<0.001. Furthermore, significant cancer was more frequent in the midline-positive group (98.5% vs. 78.0%. Conclusion: Patients showing a positive result for PC in a midline PZ biopsy were more likely to have multiple tumors or large-volume PC with a high tumor burden. However, our data indicated that an additional midline core biopsy is unlikely to be helpful in detecting occult midline PC.

  15. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  16. Cost Analysis of Channeled, Distal Chip Laryngoscope for In-office Laryngopharyngeal Biopsies.

    Science.gov (United States)

    Marcus, Sonya; Timen, Micah; Dion, Gregory R; Fritz, Mark A; Branski, Ryan C; Amin, Milan R

    2018-02-19

    Given that financial considerations play an increasingly prominent role in clinical decision-making, we sought (1) to determine the cost-effectiveness of in-office biopsy for the patient, the provider, and the health-care system, and (2) to determine the diagnostic accuracy of in-office biopsy. Retrospective, financial analyses were performed. Patients who underwent in-office (Current Procedural Terminology Code 31576) or operative biopsy (CPT Code 31535) for laryngopharyngeal lesions were included. Two financial analyses were performed: (1) the average cost of operating room (OR) versus in-office biopsy was calculated, and (2) a break-even analysis was calculated to determine the cost-effectiveness of in-office biopsy for the provider. In addition, the diagnostic accuracy of in-office biopsies and need for additional biopsies or procedures was recorded. Of the 48 patients included in the current study, 28 underwent in-office biopsy. A pathologic sample was obtained in 26 of 28 (92.9%) biopsies performed in the office. Of these patients, 16 avoided subsequent OR procedures. The average per patient cost was $7000 and $11,000 for in-office and OR biopsy, respectively. Break-even analysis demonstrated that the provider could achieve a profit 2 years after purchase of the necessary equipment. In-office laryngopharyngeal biopsies are accurate and, overall, more cost-effective than OR biopsies. Purchase of the channeled, distal chip laryngoscope and biopsy forceps to perform in-office biopsies can be profitable for a provider with a videolaryngoscopy tower. In-office biopsy should be considered the initial diagnostic tool for suspected laryngopharyngeal malignancies noted on videolaryngoscopy. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  17. Measuring propagation delay over a coded serial communication channel using FPGAs

    International Nuclear Information System (INIS)

    Jansweijer, P.P.M.; Peek, H.Z.

    2011-01-01

    Measurement and control applications are increasingly using distributed system technologies. In such applications, which may be spread over large distances, it is often necessary to synchronize system timing and know with great precision the time offsets between parts of the system. Measuring the propagation delay over a coded serial communication channel using serializer/deserializer (SerDes) functionality in FPGAs is described. The propagation delay between transmitter and receiver is measured with a resolution of a single unit interval (i.e. a serial link running at 3.125 Gbps provides a 320 ps resolution). The technique has been demonstrated to work over 100 km fibre to verify the feasibility for application in the future KM3NeT telescope.

  18. Serial analysis of gene expression (SAGE)

    NARCIS (Netherlands)

    van Ruissen, Fred; Baas, Frank

    2007-01-01

    In 1995, serial analysis of gene expression (SAGE) was developed as a versatile tool for gene expression studies. SAGE technology does not require pre-existing knowledge of the genome that is being examined and therefore SAGE can be applied to many different model systems. In this chapter, the SAGE

  19. Auditory distraction and serial memory: The avoidable and the ineluctable

    Directory of Open Access Journals (Sweden)

    Dylan M Jones

    2010-01-01

    Full Text Available One mental activity that is very vulnerable to auditory distraction is serial recall. This review of the contemporary findings relating to serial recall charts the key determinants of distraction. It is evident that there is one form of distraction that is a joint product of the cognitive characteristics of the task and of the obligatory cognitive processing of the sound. For sequences of sound, distraction appears to be an ineluctable product of similarity-of-process, specifically, the serial order processing of the visually presented items and the serial order coding that is the by-product of the streaming of the sound. However, recently emerging work shows that the distraction from a single sound (one deviating from a prevailing sequence results in attentional capture and is qualitatively distinct from that of a sequence in being restricted in its action to encoding, not to rehearsal of list members. Capture is also sensitive to the sensory task load, suggesting that it is subject to top-down control and therefore avoidable. These two forms of distraction-conflict of process and attentional capture-may be two consequences of auditory perceptual organization processes that serve to strike the optimal balance between attentional selectivity and distractability.

  20. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  1. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng [Yanshan University, Hebei (China)

    2015-10-15

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  2. Kinematics/statics analysis of a novel serial-parallel robotic arm with hand

    International Nuclear Information System (INIS)

    Lu, Yi; Dai, Zhuohong; Ye, Nijia; Wang, Peng

    2015-01-01

    A robotic arm with fingered hand generally has multi-functions to complete various complicated operations. A novel serial-parallel robotic arm with a hand is proposed and its kinematics and statics are studied systematically. A 3D prototype of the serial-parallel robotic arm with a hand is constructed and analyzed by simulation. The serial-parallel robotic arm with a hand is composed of an upper 3RPS parallel manipulator, a lower 3SPR parallel manipulator and a hand with three finger mechanisms. Its kinematics formulae for solving the displacement, velocity, acceleration of are derived. Its statics formula for solving the active/constrained forces is derived. Its reachable workspace and orientation workspace are constructed and analyzed. Finally, an analytic example is given for solving the kinematics and statics of the serial-parallel robotic arm with a hand and the analytic solutions are verified by a simulation mechanism.

  3. Piezoelectric micromotor based on the structure of serial bending arms.

    Science.gov (United States)

    Tong, Jianhua; Cui, Tianhong; Shao, Peige; Wang, Liding

    2003-09-01

    This paper presents a new piezoelectric micromotor based on the structure of serial bending arms. Serial bending arms are composed of two piezoelectric bimorphs with one end fixed and the other end free, driven by two signals of a biased square wave with a phase difference of pi/2. The free end of a cantilever arm will move along an elliptic orbit so that the cantilever is used to drive a cylinder rotor. The rotor's end surface contacts the free end of the cantilever, resulting in the rotor's rotation. There are six serial bending arms anchored on the base. The driving mechanism of the micromotor is proposed and analyzed. A new micromotor prototype, 5 mm in diameter, has been fabricated and characterized. The maximum rotational speed reaches 325 rpm, and the output torque is about 36.5 microNm.

  4. Serial position learning in honeybees.

    Directory of Open Access Journals (Sweden)

    Randolf Menzel

    Full Text Available Learning of stimulus sequences is considered as a characteristic feature of episodic memory since it contains not only a particular item but also the experience of preceding and following events. In sensorimotor tasks resembling navigational performance, the serial order of objects is intimately connected with spatial order. Mammals and birds develop episodic(-like memory in serial spatio-temporal tasks, and the honeybee learns spatio-temporal order when navigating between the nest and a food source. Here I examine the structure of the bees' memory for a combined spatio-temporal task. I ask whether discrimination and generalization are based solely on simple forms of stimulus-reward learning or whether they require sequential configurations. Animals were trained to fly either left or right in a continuous T-maze. The correct choice was signaled by the sequence of colors (blue, yellow at four positions in the access arm. If only one of the possible 4 signals is shown (either blue or yellow, the rank order of position salience is 1, 2 and 3 (numbered from T-junction. No learning is found if the signal appears at position 4. If two signals are shown, differences at positions 1 and 2 are learned best, those at position 3 at a low level, and those at position 4 not at all. If three or more signals are shown these results are corroborated. This salience rank order again appeared in transfer tests, but additional configural phenomena emerged. Most of the results can be explained with a simple model based on the assumption that the four positions are equipped with different salience scores and that these add up independently. However, deviations from the model are interpreted by assuming stimulus configuration of sequential patterns. It is concluded that, under the conditions chosen, bees rely most strongly on memories developed during simple forms of associative reward learning, but memories of configural serial patterns contribute, too.

  5. Core biopsies of the breast: Diagnostic pitfalls

    Directory of Open Access Journals (Sweden)

    Megha Joshi

    2011-01-01

    Full Text Available The incidence of breast cancer is increasing worldwide. In this review article, the authors compare and contrast the incidence of breast cancer, and the inherent differences in the United States (US and India in screening techniques used for diagnosing breast cancer. In spite of these differences, core biopsies of the breast are common for diagnosis of breast cancer in both countries. The authors describe "Best Practices" in the reporting and processing of core biopsies and in the analysis of estrogen receptor (ER, progesterone receptor (PR, and human epidermal growth factor Receptor 2 (Her2/neu. The pitfalls in the diagnosis of fibroepithelial lesions of the breast on core biopsy are discussed, as also the significance of pseudoangiomatous stromal hyperplasia of the breast (PASH is discussed in core biopsy. In this review, the management and diagnosis of flat epithelial atypia and radiation atypia are elaborated and the use of immunohistochemistry (IHC in papillary lesions, phyllodes tumor, and complex sclerosing lesions (radial scars is illustrated. Rarer lesions such as mucinous and histiocytoid carcinoma are also discussed.

  6. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  7. Dynamic low dose I-123-iodophenylpentadecanoic acid metabolic cardiac imaging

    International Nuclear Information System (INIS)

    Murray, G.L.; Magill, H.L.; Schad, N.C.

    1993-01-01

    Recognition of stunned and hibernating myocardium is essential in this era of cardiac revascularization. Positron emission tomography (PET) accurately identifies viability but is costly and unavailable to most patients. Dynamic low dose I-123-iodophenylpentadecanoic acid (IPPA) metabolic cardiac imaging is a potentially cost-effective alternative to PET. Using transmural myocardial biopsies obtained during coronary bypass surgery as the viability gold standard, resting IPPA imaging agreed with 39/43 (91%) biopsies, with a sensitivity for viability of 33/36(92%) and a specificity of 6/7 (86%) in patients with severe ischemic cardiomyopathy. Eighty percent of IPPA viable, infarcted segments improved wall motion postoperatively. Furthermore, when compared to reinjection thallium (SPECT-Tl) scans after myocardial infarction, there was IPPA-Tl concordance in 27/35 (77%)(Kappa=0.536, p=0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-Tl, 26/35 (74%) vs. 18/35 (51%)(p=0.047). Finally, when compared to transvenous endomyocardial biopsy for detecting rejection following cardiac transplantation, IPPA sensitivity for ≥Grade II rejection was 100%, and IPPA screening assessment for the necessity of biopsy could result in a 31% cost-savings. Therefore, IPPA metabolic cardiac imaging is a safe, inexpensive technique with a promising future. (author)

  8. Risk factors for bleeding complications after nephrologist-performed native renal biopsy.

    Science.gov (United States)

    Lees, Jennifer S; McQuarrie, Emily P; Mordi, Natalie; Geddes, Colin C; Fox, Jonathan G; Mackinnon, Bruce

    2017-08-01

    Bleeding is a recognized complication of native percutaneous renal biopsy. This study aimed to describe the incidence of major bleeding after biopsy in a single centre over a 15-year period and examine factors associated with major bleeding. We identified consecutive adult patients undergoing ultrasound-guided native renal biopsy in the Glasgow Renal and Transplant Unit from 2000 to 2014. From the electronic patient record, we collected data pertaining to biopsy indication, pre- and post-biopsy laboratory measurements, prescribed medication and diagnosis. Aspirin was routinely continued. We defined major bleeding post-biopsy as the need for blood transfusion, surgical or radiological intervention or death. Binary logistic regression analysis was used to assess factors associated with increased risk of major bleeding. There were 2563 patients who underwent native renal biopsy (1499 elective, 1064 emergency). The average age of patients was 57 (SD 17) years and 57.4% were male. Overall, the rate of major bleeding was 2.2%. In all, 46 patients required transfusion (1.8%), 9 patients underwent embolization (0.4%), no patient required nephrectomy and 1 patient died as a result of a significant late retroperitoneal bleed. Major bleeding was more common in those undergoing emergency compared with elective renal biopsy (3.4 versus 1.1%; P 30). The risk of major bleeding following native renal biopsy in the modern era is low. Complications are more common when biopsy is conducted as an emergency, which has implications for obtaining informed consent. Our data support the strategy of not stopping aspirin before renal biopsy.

  9. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    Science.gov (United States)

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of

  10. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  11. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  12. Renal biopsies in children: current practice and audit of outcomes.

    Science.gov (United States)

    Hussain, Farida; Mallik, Meeta; Marks, Stephen D; Watson, Alan R

    2010-02-01

    There is considerable variation in the way that children are prepared for and the techniques employed in a renal biopsy. There was national agreement between UK paediatric renal centres to review current practice and audit outcomes An initial questionnaire survey was undertaken and a 12-month prospective audit performed of renal biopsies against agreed standards for the number of needle passes, adequacy of biopsy material and complication rates. Eleven of 13 centres participated. Information leaflets are sent pre-biopsy in five centres with only one using play preparation. Six of 11 routinely perform biopsies as day-case (DC) procedures and 6 use general anaesthesia (GA). Real-time ultrasound is the favoured method in eight centres. Biopsies are performed by nephrologists only in four centres, nephrologists with radiologists in five and radiology alone in two. Of 531 biopsies (352 native), 31% were performed as a DC with 49% being done under GA. The standard for the number of passes of native kidneys (95%). The major complication rate was higher than the standard of biopsy was performed as a DC or inpatient procedure (P = 0.73) or when GA or sedation was used (P = 0.8). The audit highlights significant variation in clinical practice with limited use of preparation materials and DC procedures. The results have stimulated constructive debate about preparation and indications for biopsy and training issues. The audit enables centres and individuals to monitor performance.

  13. Kidney Biopsy in Jordan: Complications and Histopathological Findings

    Directory of Open Access Journals (Sweden)

    Ghnaimat Mohamad

    1999-01-01

    Full Text Available In this retrospective study, we reviewed the medical records, and histopathology findings of 191 patients who underwent renal biopsies at King Hussein Medical Center (KHMC during a four-year period (1993-97. All were performed using Tru-Cut needles under ultrasound guidance. There were 119 males (62.3% and 72 females (37.7%; the mean age was 29.1 years (range 5-76 years. Side effects of the renal biopsies included pain at the site of he biopsy in 17 (8.9%, gross hematuria in six (3.1% and hematuria requiring blood transfusion in one (0.5% patient. Nephrotic syndrome was the most common indication for biopsy followed by acute renal failure of unknown etiology. Among the nephritic patients, minimal change disease and post-infectious glomerulonephritis (GN were the commonest findings in children below the age of 15 years, membrano-proliferative GN ranked first in adults whole membranous GN and amyloidosis were more common in the elderly. WE conclude that renal biopsy was associated with a n acceptably low rate of complications in our practice, and that the patterns of renal histology vary slightly from those reported from other countries.

  14. Transthoracic needle biopsy: factors effecting risk of pneumothorax

    International Nuclear Information System (INIS)

    Topal, Ugur; Ediz, Buelent

    2003-01-01

    Objective: to evaluate the factors that could effect the risk of pneumothorax in patients undergoing transthoracic biopsy. Material and methods: variables that could increase the risk of pneumothorax were evaluated in 453 CT-guided transthoracic biopsies. Factors were evaluated in two groups: (1) lesion related (presence of emphysema around the lesion, lesion depth, cavitation, presence of fissure/atelectasis and pleural tag in the needle trajectory); and (2) procedure related (biopsy type, needle size, number of passages, level of experience of the operator). All variables were analysed by χ 2 test and multivariate logistic regression statistics. Results: pneumothorax was developed in 85 (18.8%) out of 453 procedures. A chest tube was inserted in ten (11.7%) of them. Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P<0.001) and severity of the emphysema (P<0.01). Conclusion: the length of the lung parenchyma traversed during the biopsy is the predominant risk factor for pneumothorax in patients undergoing CT-guided transthoracic biopsy. The risk of pneumothorax was also increased with the severity of the emphysema around the lesion

  15. Advances in Serials Management. Volume 6.

    Science.gov (United States)

    Hepfer, Cindy, Ed.; Gammon, Julia, Ed.; Malinowski, Teresa, Ed.

    In order to further discussion and support constructive change, this volume presents the following eight papers on various dimensions of serials management: (1) "CD-ROMs, Surveys, and Sales: The OSA [Optical Society of America] Experience" (Frank E. Harris and Alan Tourtlotte); (2) "Management and Integration of Electronic Journals into the…

  16. Impact of Serials Management, Access and Use on Publication Output of Lecturers in Nigerian Universities

    Science.gov (United States)

    Akinbode, Rahmon O. Onaolapo; Nwalo, Kenneth Ivo Ngozi

    2017-01-01

    This study investigates serials management in university libraries, determines the extent to which serials are accessed and used and appraises the influence of availability, accessibility and use of serials on publications output of lecturers in federal universities in Nigeria. Questionnaire administration method was adopted to accumulate data for…

  17. Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcification

    International Nuclear Information System (INIS)

    Sim, L. S. J.; Kei, P. L.

    2008-01-01

    Full text: Stereotactic core needle biopsy is a useful technique for evaluation of suspicious breast microcalcifications. Thf development of the 11-G vacuum-assisted biopsy system offers another method of minimally invasive biopsy carried out on a conventional mammography unit. We evaluate its usefulness, efficacy and safety in Asian women.. Vacuum-assisted biopsy was carried out through the lateral approach using an add-on stereotactic device attached to a mammography unit. One hundred and five lesions were sampled in 97 patients. Excisional biopsy was subsequently Carried out for diagnosis of atypical ductal hyperplasia or carcinoma in high-risk patients. Patients with benign diagnosis underwent mammographic follow up. The technical success rate was 97%. An average of 13.5 tissue cores were retrieved for each lesion. The histopathological result obtained from mammotome was benign in 84.8% and malignant in 15.2%. The benign microcalcifications were predominantly fibrocystic change (n = 42)| whereas the malignant microcalcifications included ductal carcinoma in situ (n = 15) and invasive carcinoma (n = 1). Twenty-two patients underwent subsequent open surgical biopsy but no underestimation of disease was seen. Only two patients had vasovagal syncope and three others felt unwell during the biopsy. Nine patients had small haema-1 tomas, which resolved spontaneously. Vacuum-assisted biopsy carried out on an upright stereotactic mammography] unit is a safe and effective method for evaluation of suspicious microcalcifications.

  18. The Utility of Endoscopic Biopsies in Patients with Normal Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Anouar Teriaky

    2016-01-01

    Full Text Available Background and Aims. Upper endoscopy is a valuable tool in the workup of gastrointestinal (GI complaints. The purpose of this study is to determine cost and yield of taking biopsies in a normal upper GI tract. Methods. This is a retrospective study where all upper GI biopsies were identified between May 2012 and April 2013, at a tertiary care center. Clinical, procedural, and pathology reports were reviewed to identify patient demographics, procedure information, and pathology diagnosis. Results. Biopsies of the upper GI tract were taken in 1297 patients with normal upper endoscopies. In patients with normal upper endoscopy, 22% of esophageal, 44% of gastric, and 12% of duodenal biopsies were abnormal. The most frequent abnormality was reflux esophagitis in 16% of esophageal biopsies, chronic gastritis in 23% of gastric biopsies, and increased intraepithelial lymphocytes in 6% of duodenal biopsies. The additional cost for taking biopsies in a normal upper GI tract for a diagnosis of eosinophilic esophagitis was $2963 Canadian (CAD, H. pylori associated gastritis was $1404 CAD, and celiac disease was $3024 CAD. Conclusions. The yield of biopsy in normal upper endoscopy varied with location, but the additional expense can be costly and should be tailored to appropriate clinical situations.

  19. Fungal myositis in children: serial ultrasonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jung Hwa; Lee, Hee Jung; Choi, Jin Soo [Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2003-08-01

    To evaluate serial ultrasonographic findings of fungal myositis in children. Eleven lesions caused by fungal myositis and occurring in six children were included in this study. Eight lesions in five children were histopathologically proven and the other three were clinically diagnosed. Serial ultrasonographic findings were retrospectively evaluated in terms of size, location, margin, internal echotexture and adjacent cortical change occurring during the follow-up period ranging from five days to two months. Three patients (50%) had multiple lesions. The sites of involvment were the thigh (n=4), calf (n=3), chest wall (n=2), abdominal wall (n=1) and forearm (n=1). Initially, diffuse muscular swelling was revealed, with ill-defined hypoechoic lesions confined to the muscle layer (n=8). Follow-up examination of eight lesions over a period of 5-10 days showed that round central echogenic lesions were surrounded by previous slightly echogenic lesions (n=6, 75%). Long-term follow-up of five lesions over a two-month period revealed periosteal thickening in one case (20%), and the peristence of echogenic solid nodules in four (80%). Pathologic examination showed that the central lesions correlated with a fungus ball and the peripheral slightly echogenic lesions corresponded to hematoma and necrosis. Serial ultrasonographic findings of fungal myositis in children revealed relatively constant features in each case. In particular, the findings of muscular necrosis and a fungus ball over a period of 5-14 days were thought to be characteristic.

  20. Fungal myositis in children: serial ultrasonographic findings

    International Nuclear Information System (INIS)

    Kwon, Jung Hwa; Lee, Hee Jung; Choi, Jin Soo

    2003-01-01

    To evaluate serial ultrasonographic findings of fungal myositis in children. Eleven lesions caused by fungal myositis and occurring in six children were included in this study. Eight lesions in five children were histopathologically proven and the other three were clinically diagnosed. Serial ultrasonographic findings were retrospectively evaluated in terms of size, location, margin, internal echotexture and adjacent cortical change occurring during the follow-up period ranging from five days to two months. Three patients (50%) had multiple lesions. The sites of involvment were the thigh (n=4), calf (n=3), chest wall (n=2), abdominal wall (n=1) and forearm (n=1). Initially, diffuse muscular swelling was revealed, with ill-defined hypoechoic lesions confined to the muscle layer (n=8). Follow-up examination of eight lesions over a period of 5-10 days showed that round central echogenic lesions were surrounded by previous slightly echogenic lesions (n=6, 75%). Long-term follow-up of five lesions over a two-month period revealed periosteal thickening in one case (20%), and the peristence of echogenic solid nodules in four (80%). Pathologic examination showed that the central lesions correlated with a fungus ball and the peripheral slightly echogenic lesions corresponded to hematoma and necrosis. Serial ultrasonographic findings of fungal myositis in children revealed relatively constant features in each case. In particular, the findings of muscular necrosis and a fungus ball over a period of 5-14 days were thought to be characteristic

  1. Race as Seriality: A Response to David Benatar and Zimitri Erasmus

    Science.gov (United States)

    Gouws, A.

    2010-01-01

    In this article I draw on the Sarte's notion of "seriality" as theorized in his book "Dialectic of Reason" and as interpreted by Iris Marion Young. I argue that seriality can be used to escape the false essentialism and identity politics of race as a category for admissions to universities. A series is a social collective whose members are unified…

  2. Closed Pericardial Biopsy

    African Journals Online (AJOL)

    1974-09-28

    Sep 28, 1974 ... The instrument used is a hook biopsy needle (Fig. I). manufactured by Becton, Dickinson and Co., Rutherford,. New Jersey, USA. The instrument' and technique' will be reviewed. The instrument consists of an ll-gauge needle with a sharp cutting edge into which fits, interchangeably, a 13-gauge needle or a ...

  3. Bone marrow trephine biopsies: A single centre experience in Eastern India

    Directory of Open Access Journals (Sweden)

    Sima Chauhan

    2017-01-01

    Full Text Available Introduction: Bone marrow aspiration (BMA and trephine biopsy are indispensable diagnostic tools for evaluating hematological and nonhematological disorders in the present era. However, trephine biopsy demands greater technical skills and expertise as compared to BMA alone. In this study, we have analyzed the advantages of carrying out trephine biopsy along with BMA in the same sitting. Materials and Methods: This is a prospective observational study carried out from June 2014 to May 2015. The patients attending hematology and medicine outdoors were screened by detailed clinical examination, laboratory investigations including complete blood counts, peripheral smear, and whenever indicated were subjected to BMA and trephine biopsy in the same sitting. Results: Out of total 570 aspirations and trephine biopsies done, 8% showed inadequate aspirates and diagnosis was based only on biopsy findings. Confirmatory diagnosis of aplastic anemia was done on trephine biopsy in 100% cases. Fifty percent cases of granulomas and 33.3% cases of metastasis were missed in aspiration smears. They were diagnosed on trephine biopsy. All cases of myelofibrosis required trephine biopsy for diagnosis, but aspiration alone was adequate for diagnosis in majority of acute leukemias. Conclusion: Trephine biopsy is mandatory for diagnosis of aplastic anemia, myelofibrosis, and for staging of lymphomas. It specially carries diagnostic value in cases of dry tap and bloody aspirates. Aspiration is simple, has high specificity, and is especially useful for nutritional anemia, immune thrombocytopenia, acute leukemia, and multiple myeloma.

  4. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  5. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  6. Diagnostic Accuracy of Robot-Guided, Software Based Transperineal MRI/TRUS Fusion Biopsy of the Prostate in a High Risk Population of Previously Biopsy Negative Men

    Directory of Open Access Journals (Sweden)

    Malte Kroenig

    2016-01-01

    Full Text Available Objective. In this study, we compared prostate cancer detection rates between MRI-TRUS fusion targeted and systematic biopsies using a robot-guided, software based transperineal approach. Methods and Patients. 52 patients received a MRIT/TRUS fusion followed by a systematic volume adapted biopsy using the same robot-guided transperineal approach. The primary outcome was the detection rate of clinically significant disease (Gleason grade ≥ 4. Secondary outcomes were detection rate of all cancers, sampling efficiency and utility, and serious adverse event rate. Patients received no antibiotic prophylaxis. Results. From 52 patients, 519 targeted biopsies from 135 lesions and 1561 random biopsies were generated (total n=2080. Overall detection rate of clinically significant PCa was 44.2% (23/52 and 50.0% (26/52 for target and random biopsy, respectively. Sampling efficiency as the median number of cores needed to detect clinically significant prostate cancer was 9 for target (IQR: 6–14.0 and 32 (IQR: 24–32 for random biopsy. The utility as the number of additionally detected clinically significant PCa cases by either strategy was 0% (0/52 for target and 3.9% (2/52 for random biopsy. Conclusions. MRI/TRUS fusion based target biopsy did not show an advantage in the overall detection rate of clinically significant prostate cancer.

  7. A randomized, prospective cross-over trial comparing methylene blue-directed biopsy and conventional random biopsy for detecting intestinal metaplasia and dysplasia in Barrett's esophagus.

    Science.gov (United States)

    Ragunath, K; Krasner, N; Raman, V S; Haqqani, M T; Cheung, W Y

    2003-12-01

    The value of methylene blue-directed biopsies (MBDB) in detecting specialized intestinal metaplasia and dysplasia in Barrett's esophagus remains unclear. The aim of this study was to compare the accuracy of MBDB with random biopsy in detecting intestinal metaplasia and dysplasia in patients with Barrett's esophagus. A prospective, randomized, cross-over trial was undertaken to compare MBDB with random biopsy in patients with Barrett's esophagus segments 3 cm or more in length without macroscopic evidence of dysplasia or cancer. Dysplasia was graded as: indefinite for dysplasia, low-grade dysplasia, high-grade dysplasia, or carcinoma, and was reported in a blinded fashion. Fifty-seven patients were recruited, 44 of whom were male. A total of 1,269 biopsies were taken (MBDB-651, random biopsie-618). Analysis of the results by per-biopsy protocol showed that the MBDB technique diagnosed significantly more specialized intestinal metaplasia (75 %) compared to the random biopsy technique (68 %; P = 0.032). The sensitivity and specificity rates of MBDB for diagnosing specialized intestinal metaplasia were 91 % (95 % CI, 88 - 93 %) and 43 % (95 % CI, 36 - 51 %), respectively. The sensitivity and specificity rates of MBDB for diagnosing dysplasia or carcinoma were 49 % (95 % CI, 38 - 61 %) and 85 % (95 % CI, 82 - 88 %), respectively. There were no significant differences in the diagnosis of dysplasia and carcinoma - MBDB 12 %, random biopsy 10 %. The methylene blue staining pattern appeared to have an influence on the detection of specialized intestinal metaplasia and dysplasia/carcinoma. Dark blue staining was associated with increased detection of specialized intestinal metaplasia (P biopsies. Although MBDB prolongs the endoscopy procedure slightly, it is a safe and well-tolerated procedure. Further clinical studies on the MBDB technique exclusively in endoscopically normal dysplastic Barrett's esophagus are needed.

  8. Postradiotherapy prostate biopsies: what do they really mean? results for 498 patients

    International Nuclear Information System (INIS)

    Crook, Juanita; Malone, Shawn; Perry, Gad; Bahadur, Yasir; Robertson, Susan; Abdolell, Mohamed

    2000-01-01

    Purpose: Postradiotherapy (RT) prostate biopsies are prone to problems in interpretation. False negatives due to sampling error, false positives due to delayed tumor regression, and indeterminate biopsies showing radiation effect in residual tumor of uncertain viability are common occurrences. Methods and Materials: A cohort of 498 men treated with conventional RT from 06/87-10/96 were followed prospectively with systematic transrectal ultrasound (TRUS)-guided post-RT prostate biopsies, starting 12-18 months after RT. If there was residual tumor but further decline in serum prostate-specific antigen (PSA), biopsies were repeated every 6-12 months. Patients with negative biopsies were rebiopsied at 36 months. Residual tumor was evaluated for RT effect and proliferation markers. The 498 men had 978 biopsies. Median time of the first biopsy (n = 498) was 13 months, biopsy no. 2 (n = 342) 28 months, biopsy no. 3 (n = 110) 36 months, biopsy no. 4 (n = 28) 44 months, and biopsy no. 5 (n = 4) 55 months. Median follow-up is 54 months (range 13-131). One hundred seventy-five patients (34%) had prior hormonal therapy for a median of 5 months (range 1-60). Results: Clinical stage distribution was T1b: 46; T1c: 50; T2a: 115; T2b/c: 170; T3: 108; T4: 11; Tx: 1. Distribution by Gleason score was: 28% Gleason score 2-4; 42%: 5-6; 18%: 7; and 12%: 8-10. Seventy-one men have died, 26 of prostate cancer and 45 of other causes. Actuarial failure-free survival by T stage at 5 years is T1b: 78%; T1c: 76%; T2a: 60%; T2b/c: 55%; T3: 30%; and T4: 0%. Actuarial freedom from local failure at 5 years is T1b: 83%; T1c: 88%; T2a: 72%; T2b/c: 66%; T3: 58%; and T4: 0%. The proportion of indeterminate biopsies decreases with time, being 33% for biopsy 1, 24% for biopsy 2, 18% for biopsy 3, and 7% for biopsy 4. Thirty percent of indeterminate biopsies resolved to NED status, regardless of the degree of RT effect, 18% progressed to local failure, and 34% remained as biopsy failures with

  9. A high speed serializer ASIC for ATLAS Liquid Argon calorimeter upgrade

    CERN Document Server

    Liu, T; The ATLAS collaboration

    2014-01-01

    We have been developing a serializer application-specific integrated circuit (ASIC) based on a commercial 0.25-μm silicon-on-sapphire (SOS) CMOS technology for the ATLAS liquid argon calorimeter front-end electronics upgrade. The first prototype, a 5 Gbps 16:1 serializer has been designed, fabricated, and tested in lab environment and in 200 MeV proton beam. The test results indicate that the first prototype meets the design goals. The second prototype, a double-lane, 8 Gbps per lane serializer is under development. The post layout simulation indicates that 8 Gbps is achievable. In this paper we present the design and the test results of the first prototype and the design and status of the second prototype.

  10. Respiratory analysis of coupled mitochondria in cryopreserved liver biopsies

    Directory of Open Access Journals (Sweden)

    Mercedes García-Roche

    2018-07-01

    Full Text Available The aim of this work was to develop a cryopreservation method of small liver biopsies for in situ mitochondrial function assessment. Herein we describe a detailed protocol for tissue collection, cryopreservation, high-resolution respirometry using complex I and II substrates, calculation and interpretation of respiratory parameters. Liver biopsies from cow and rat were sequentially frozen in a medium containing dimethylsulfoxide as cryoprotectant and stored for up to 3 months at −80 °C. Oxygen consumption rate studies of fresh and cryopreserved samples revealed that most respiratory parameters remained unchanged. Additionally, outer mitochondrial membrane integrity was assessed adding cytochrome c, proving that our cryopreservation method does not harm mitochondrial structure. In sum, we present a reliable way to cryopreserve small liver biopsies without affecting mitochondrial function. Our protocol will enable the transport and storage of samples, extending and facilitating mitochondrial function analysis of liver biopsies. Keywords: Cryopreservation, Mitochondria, Biopsy, Oxygen consumption rate, High-resolution respirometry, Mitochondrial function

  11. Facial rejuvenation: Serial fat graft transfer

    African Journals Online (AJOL)

    Saad Mohamed Saad Ibrahiem

    2016-02-01

    Feb 1, 2016 ... This a clinical study carried out to test the aesthetic outcome of serial injection of the cryo-preserved fat cells for both aesthetic and reconstructive purposes. Methods: Clinical ..... ucts, devices, or drugs mentioned in this manuscript that might create a ... Adipose stem cells and regenerative medicine. 7th ed.

  12. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  13. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  14. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    International Nuclear Information System (INIS)

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-01-01

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  15. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  16. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  17. Smart grid serialization comparison: Comparision of serialization for distributed control in the context of the Internet of Things

    DEFF Research Database (Denmark)

    Petersen, Bo Søborg; Bindner, Henrik W.; You, Shi

    2017-01-01

    within a given timeframe, especially in the context of the Internet of Things, using low-bandwidth data connections and constrained devices. The paper shows that there are better alternatives than XML & JAXB and gives guidance in choosing the most appropriate serialization format and library depending...

  18. Analysis of aging in lager brewing yeast during serial repitching.

    Science.gov (United States)

    Bühligen, Franziska; Lindner, Patrick; Fetzer, Ingo; Stahl, Frank; Scheper, Thomas; Harms, Hauke; Müller, Susann

    2014-10-10

    Serial repitching of brewing yeast inoculates is an important economic factor in the brewing industry, as their propagation is time and resource intensive. Here, we investigated whether replicative aging and/or the population distribution status changed during serial repitching in three different breweries with the same brewing yeast strain but different abiotic backgrounds and repitching regimes with varying numbers of reuses. Next to bud scar numbers the DNA content of the Saccharomyces pastorianus HEBRU cells was analyzed. Gene expression patterns were investigated using low-density microarrays with genes for aging, stress, storage compound metabolism and cell cycle. Two breweries showed a stable rejuvenation rate during serial repitching. In a third brewery the fraction of virgin cells varied, which could be explained with differing wort aeration rates. Furthermore, the number of bud scars per cell and cell size correlated in all 3 breweries throughout all runs. Transcriptome analyses revealed that from the 6th run on, mainly for the cells positive gene expression could be seen, for example up-regulation of trehalose and glycogen metabolism genes. Additionally, the cells' settling in the cone was dependent on cell size, with the lowest and the uppermost cone layers showing the highest amount of dead cells. In general, cells do not progressively age during extended serial repitching. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Native sulfur/chlorine SAD phasing for serial femtosecond crystallography

    International Nuclear Information System (INIS)

    Nakane, Takanori; Song, Changyong; Suzuki, Mamoru; Nango, Eriko; Kobayashi, Jun; Masuda, Tetsuya; Inoue, Shigeyuki; Mizohata, Eiichi; Nakatsu, Toru; Tanaka, Tomoyuki; Tanaka, Rie; Shimamura, Tatsuro; Tono, Kensuke; Joti, Yasumasa; Kameshima, Takashi; Hatsui, Takaki; Yabashi, Makina; Nureki, Osamu; Iwata, So; Sugahara, Michihiro

    2015-01-01

    Sulfur SAD phasing facilitates the structure determination of diverse native proteins using femtosecond X-rays from free-electron lasers via serial femtosecond crystallography. Serial femtosecond crystallography (SFX) allows structures to be determined with minimal radiation damage. However, phasing native crystals in SFX is not very common. Here, the structure determination of native lysozyme from single-wavelength anomalous diffraction (SAD) by utilizing the anomalous signal of sulfur and chlorine at a wavelength of 1.77 Å is successfully demonstrated. This sulfur SAD method can be applied to a wide range of proteins, which will improve the determination of native crystal structures

  20. Laparoscopic splenic biopsy in dogs and cats: 15 cases (2006-2008).

    Science.gov (United States)

    Radhakrishnan, Anant; Mayhew, Philipp D

    2013-01-01

    This retrospective study describes a technique and evaluates outcome associated with laparoscopic splenic biopsy in dogs and cats. Medical records of dogs (n = 10) and cats (n = 5) that had a laparoscopic splenic biopsy performed as part of their diagnostic evaluation for systemic disease were evaluated. Splenic biopsies were performed with the patient in dorsal recumbency using a two-portal approach. In some cases, concurrent organ biopsy was also performed. A pair of 5 mm cup biopsy forceps was used for biopsy collection, and an absorbable gelatin hemostatic sponge was placed at the biopsy site to aid in hemostasis. All patients recovered without major complications. Conversion to an open surgical approach was not required. Median survival time was 180 days, and nine patients were alive at the time of manuscript preparation. Four patients were diagnosed with neoplasia; however, only one had neoplasia involving the spleen. Median survival time for the nonneoplasia group (n = 11) was 300 days. Eight of those patients were alive at time of manuscript preparation. Minimal morbidity was observed in this cohort of clinical patients. Histopathology may be preferred over cytology in some clinical situations, and laparoscopic splenic biopsy provides a minimally invasive diagnostic option.

  1. The death of recency: Relationship between end-state comfort and serial position effects in serial recall: Logan and Fischman (2011) revisited.

    Science.gov (United States)

    Logan, Samuel W; Fischman, Mark G

    2015-12-01

    Two experiments examined the dynamic interaction between cognitive resources in short-term memory and bimanual object manipulation by extending recent research by Logan and Fischman (2011). In Experiment 1, 16 participants completed a bimanual end-state comfort task and a memory task requiring serial recall of 12 words or pictures. The end-state comfort task involved moving two glasses between two shelves. Participants viewed the items, performed the end-state comfort task, and then serially recalled the items. Recall was evaluated by the presence or absence of primacy and recency effects. The end-state comfort effect (ESCE) was assessed by the percentage of initial hand positions that allowed the hands to end comfortably. The main findings indicated that the ESCE was disrupted; the primacy effect remained intact; and the recency effect disappeared regardless of the type of memory item recalled. In Experiment 2, 16 participants viewed six items, performed an end-state comfort task, viewed another six items, and then serially recalled all 12 items. Results were essentially the same as in Experiment 1. Findings suggest that executing a bimanual end-state comfort task, regardless of when it is completed during a memory task, diminishes the recency effect irrespective of the type of memory item. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. On the Performance of the Python Programming Language for Serial and Parallel Scientific Computations

    Directory of Open Access Journals (Sweden)

    Xing Cai

    2005-01-01

    Full Text Available This article addresses the performance of scientific applications that use the Python programming language. First, we investigate several techniques for improving the computational efficiency of serial Python codes. Then, we discuss the basic programming techniques in Python for parallelizing serial scientific applications. It is shown that an efficient implementation of the array-related operations is essential for achieving good parallel performance, as for the serial case. Once the array-related operations are efficiently implemented, probably using a mixed-language implementation, good serial and parallel performance become achievable. This is confirmed by a set of numerical experiments. Python is also shown to be well suited for writing high-level parallel programs.

  3. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  4. Seven cases of upper gastrointestinal bleeding after cold biopsy

    OpenAIRE

    Alneaimi, Khaled; Abdelmoula, Ali; Vincent, Magalie; Savale, Camille; Baye, Birane; Lesur, Gilles

    2016-01-01

    Background and study aims: Routine biopsy of the upper gastrointestinal tract is performed with increasing frequency. It is generally considered to be safe without significant complication. However, gastrointestinal bleeding as a result of cold biopsy is a known complication. We report seven cases of upper gastrointestinal bleeding after cold biopsy and discuss clinical data, risks factors, severity and management of this event. We suggest that physicians must be more cautious with this rare ...

  5. THE PROGNOSTIC AND DIAGNOSTIC VALUE OF REPEATED TRANSRECTAL PROSTATE SATURATION BIOPSY

    Directory of Open Access Journals (Sweden)

    M. A. Kurdzhiev

    2014-08-01

    Full Text Available Objective: to determine the rate of prostate cancer (PC development after repeated transrectal saturation prostate biopsy (RTRSPB, to study the characteristics of diagnosed tumors, and to estimate their clinical significance from the data of radical retropubic prostatectomy (RRP.Materials and methods. The results of RTRSPB were analyzed in 226 patients with a later evaluation of a tumor from the results of RRP. All the patients underwent at least 2 prostate biopsies (mean 2.4. The average number of biopsy cores was 26.7 (range 24—30. The average value of total prostate-specific antigen before saturation biopsy was 7.5 (range 7.5 to 28.6 ng/ml. The mean age of patients was 62 years (range 53 to 70.  Results. PC was diagnosed in 14.6% of cases (33/226. An isolated lesion of the prostatic transition zone was in 12.1% of cases. If this zone had been excluded from the biopsy scheme, the detection rate of PC during saturation biopsy should be reduced by 13.8%. Better PC detectability during repeated saturation biopsy generally occurred due to the localized forms of the disease (93.3%. The agreement of Gleason tumor grading in the biopsy and prostatectomy specimens was noted in 66.7% of cases.Conclusion. Saturation biopsy allows prediction of a pathological stage of PC, Gleason grade of a tumor and its site localization with a greater probability. Most tumors detectable by saturation biopsy were clinically significant, which makes it possible to recommend RTRSPB to some cohort of high PC-risk patients 

  6. Magnetic-resonance-guided biopsy of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ethan A. [University of Michigan Health System, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Grove, Jason J. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Der Spek, Abraham F.L.V. [University of Michigan Health System, Department of Anesthesiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Jarboe, Marcus D. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Department of Surgery, Ann Arbor, MI (United States)

    2017-05-15

    Image-guided biopsy techniques are widely used in clinical practice. Commonly used methods employ either ultrasound (US) or computed tomography (CT) for image guidance. In certain patients, US or CT guidance may be suboptimal, or even impossible, because of artifacts, suboptimal lesion visualization, or both. We recently began performing magnetic resonance (MR)-guided biopsy of focal liver lesions in select pediatric patients with lesions that are not well visualized by US or CT. This report describes our experience performing MR-guided biopsy of focal liver lesions, with case examples to illustrate innovative techniques and novel aspects of these procedures. (orig.)

  7. Remote biopsy darting and marking of polar bears

    Science.gov (United States)

    Pagano, Anthony M.; Peacock, Elizabeth; McKinney, Melissa A.

    2014-01-01

    Remote biopsy darting of polar bears (Ursus maritimus) is less invasive and time intensive than physical capture and is therefore useful when capture is challenging or unsafe. We worked with two manufacturers to develop a combination biopsy and marking dart for use on polar bears. We had an 80% success rate of collecting a tissue sample with a single biopsy dart and collected tissue samples from 143 polar bears on land, in water, and on sea ice. Dye marks ensured that 96% of the bears were not resampled during the same sampling period, and we recovered 96% of the darts fired. Biopsy heads with 5 mm diameters collected an average of 0.12 g of fur, tissue, and subcutaneous adipose tissue, while biopsy heads with 7 mm diameters collected an average of 0.32 g. Tissue samples were 99.3% successful (142 of 143 samples) in providing a genetic and sex identification of individuals. We had a 64% success rate collecting adipose tissue and we successfully examined fatty acid signatures in all adipose samples. Adipose lipid content values were lower compared to values from immobilized or harvested polar bears, indicating that our method was not suitable for quantifying adipose lipid content.

  8. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  9. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  10. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  11. Mammotome HH biopsy - the future of minimal invasive breast surgery?

    International Nuclear Information System (INIS)

    Pietrzyk, G.; Nowicki, J.; Bojarski, B.; Kedzierski, B.; Wysocki, A.; Prudlak, E.

    2007-01-01

    Vacuum-assisted breast biopsy / Mammotome HH '' R '' Breast Biopsy System/ is the milestone in the diagnosis of breast lesions. This system has proven to be as diagnostically reliable as open surgery, but without scarring, deformations and hospitalizations associated with an open procedure. The aim of our study was to assess the role and possibilities of using this biopsy in treatment of benign breast lesions like fibroadenoma. From 2001 to 2004, about 1118 Mammotome biopsies were performed in our Department. Among 445 Mammotome biopsies performed under US control there were 211 cases of fibroadenomas. Follow-up was performed in 156 patients with this result at 6 and 12 months after biopsy. In our study we took into considerations the size, localizations as well as performers. In 2002 there were 70.8% patients with total lesion excision, 16.7% with residual lesion and 12.5% women with hematomas or scars. In 2003-2004 there were more women with total lesion excision (84.3%), fewer residual tumors and other lesions. In future, Mammotome breast biopsy can replace scalpel, and will become an alternative method to open surgical excision of fibroadenomas. It is important especially in the cases of young women to prevent cosmetic deformations and scars. (author)

  12. How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

    International Nuclear Information System (INIS)

    Oppenheimer, Jason D.; Kasuganti, Deepa; Nayar, Ritu; Chrisman, Howard B.; Lewandowski, Robert J.; Nemcek, Albert A.; Ryu, Robert K.

    2010-01-01

    Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists under US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.

  13. Impaired Processing of Serial Order Determines Working Memory Impairments in Alzheimer's Disease.

    Science.gov (United States)

    De Belder, Maya; Santens, Patrick; Sieben, Anne; Fias, Wim

    2017-01-01

    Working memory (WM) problems are commonly observed in Alzheimer's disease (AD), but the affected mechanisms leading to impaired WM are still insufficiently understood. The ability to efficiently process serial order in WM has been demonstrated to be fundamental to fluent daily life functioning. The decreased capability to mentally process serial position in WM has been put forward as the underlying explanation for generally compromised WM performance. Determine which mechanisms, such as order processing, are responsible for deficient WM functioning in AD. A group of AD patients (n = 32) and their partners (n = 25), assigned to the control group, were submitted to an extensive battery of neuropsychological and experimental tasks, assessing general cognitive state and functioning of several aspects related to serial order WM. The results revealed an impaired ability to bind item information to serial position within WM in AD patients compared to controls. It was additionally observed that AD patients experienced specific difficulties with directing spatial attention when searching for item information stored in WM. The processing of serial order and the allocation of attentional resources are both disrupted, explaining the generally reduced WM functioning in AD patients. Further studies should now clarify whether this observation could explain disease-related problems for other cognitive functions such as verbal expression, auditory comprehension, or planning.

  14. Markers of immune activation and apoptosis in endomyocardial biopsies of individuals with recent-onset dilated cardiomyopathy

    Czech Academy of Sciences Publication Activity Database

    Kubánek, M.; Sramko, M.; Malušková, J.; Chudíčková, Milada; Holáň, Vladimír; Kautzner, J.

    2013-01-01

    Roč. 34, č. 1 (2013), s. 211-211 ISSN 0195-668X. [Congress of the European-Society-of- Cardiology (ESC). 31.08.2013-,04.09.2013, Amsterdam] Institutional support: RVO:68378041 Keywords : dilated cardiomyopathy * immune activation and apoptosis Subject RIV: EC - Immunology

  15. CONE BIOPSY IN PREGNANCY*

    African Journals Online (AJOL)

    1 Mei 1971. S.-A. TYDSKRIF VIR OBSTETRIE EN GINEKOLOGIE. CONE BIOPSY ... of the abnormal cervix in pregnancy is also no longer in question following the .... the concept of cancer prophylaxis to the majority of women, many of whom ...

  16. Serializing off-the-shelf MOSFETs by Magnetically Coupling Their Gate Electrodes

    DEFF Research Database (Denmark)

    Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2013-01-01

    While the semiconductor industry struggles with the inherent trade-offs of solid-state devices, serialization of power switches, like the Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) or the Insulated Gate Bipolar Transistor (IGBT), has been proven to be an advantageous alternative...... to acquire a high-efficient, high-voltage, fast-switching device. More than twenty years of research, on the serialization of solid-state devices, have resulted into several different stacking concepts. Among the prevailing ones, the gate balancing core technique, which has demonstrated very good performance...... in strings of high-power IGBT modules. In this paper, the limitations of the gate balancing core technique, when employed to serialize low or medium power off-the-shelf switches, are identified via experimental results. A new design specification for the interwinding capacitance of the employed transformer...

  17. Morphological pattern of endometrial biopsies in southwestern Nigeria

    African Journals Online (AJOL)

    Background: Endometrium remains the most sensitive indicator of ovarian function and endometrial biopsy is one of the diagnostic procedures in endometrial pathology. The current study was carried out to examine the morphological pattern of endometrial biopsies in Ibadan, South-western Nigeria and compare the results ...

  18. Duodenal versus jejunal biopsies in suspected celiac disease

    NARCIS (Netherlands)

    Thijs, WJ; van Baarlen, J; Kleibeuker, JH; Kolkman, JJ

    2004-01-01

    Background and Study Aims: In the past, small-bowel biopsies for diagnosis of celiac disease were taken from the jejunum with a suction capsule, but nowadays most physicians take endoscopic biopsies from the distal duodenum. To validate that practice we compared the diagnostic yield of endoscopic

  19. Recalling visual serial order for verbal sequences

    NARCIS (Netherlands)

    Logie, R.H.; Saito, S.; Morita, A.; Varma, S.; Norris, D.

    2016-01-01

    We report three experiments in which participants performed written serial recall of visually presented verbal sequences with items varying in visual similarity. In Experiments 1 and 2 native speakers of Japanese recalled visually presented Japanese Kanji characters. In Experiment 3, native speakers

  20. A matter of emphasis: Linguistic stress habits modulate serial recall.

    Science.gov (United States)

    Taylor, John C; Macken, Bill; Jones, Dylan M

    2015-04-01

    Models of short-term memory for sequential information rely on item-level, feature-based descriptions to account for errors in serial recall. Transposition errors within alternating similar/dissimilar letter sequences derive from interactions between overlapping features. However, in two experiments, we demonstrated that the characteristics of the sequence are what determine the fates of items, rather than the properties ascribed to the items themselves. Performance in alternating sequences is determined by the way that the sequences themselves induce particular prosodic rehearsal patterns, and not by the nature of the items per se. In a serial recall task, the shapes of the canonical "saw-tooth" serial position curves and transposition error probabilities at successive input-output distances were modulated by subvocal rehearsal strategies, despite all item-based parameters being held constant. We replicated this finding using nonalternating lists, thus demonstrating that transpositions are substantially influenced by prosodic features-such as stress-that emerge during subvocal rehearsal.