WorldWideScience

Sample records for serial blood collection

  1. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  2. Serials collection management in recessionary times

    CERN Document Server

    Lawson, Karen G

    2015-01-01

    Strategic planning, collaboration, continual stewardship, best practices, and re-engineering can provide librarians with a toolkit of innovative strategies that meets the worst of economic times with bold, persistent experimentation. This book covers the implications for libraries of a broad range of technological and economic challenges. These challenges include the fallout from the global economic crisis, the positioning of usage statistics, the advent of open access scholarship, database management, responding to budgetary constrictions and general access to serials. Taken as a whole, this

  3. Benchmarking Usage Statistics in Collection Management Decisions for Serials

    Science.gov (United States)

    Tucker, Cory

    2009-01-01

    Usage statistics are an important metric for making decisions on serials. Although the University of Nevada, Las Vegas (UNLV) Libraries have been collecting usage statistics, the statistics had not frequently been used to make decisions and had not been included in collection development policy. After undergoing a collection assessment, the…

  4. Bloody Fast Blood Collection

    NARCIS (Netherlands)

    van Brummelen, Samuel Pieter Josephus

    2017-01-01

    This thesis consists of four parts: The first part contains an introduction, the second presents approaches for the evaluation of waiting times at blood collection sites, the third uses these to present approaches that improve waiting times at blood collection sites. The final part shows the

  5. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Peripheral blood collection

    DEFF Research Database (Denmark)

    Franken, Carmen; Remy, Sylvie; Lambrechts, Nathalie

    2016-01-01

    A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of mRNA in the prese......A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of m......RNA in the presence of different stabilization buffers (TempusTM Blood RNA tube and RNAlater® Stabilization Reagent). Microarray analyzes showed significant changes over short periods of time in expression of a considerate part of the transcriptome (2356 genes) with a prominent role for NFкB-, cancer......- and glucocorticoid-mediated networks, and specifically interleukin-8 (IL-8). These findings suggest that even short bench times affect gene expression, requiring to carry out blood collection in a strictly standardized way. © 2016 Informa UK Limited, trading as Taylor & Francis Group....

  7. Serial changes in plasma K concentration during storage of irradiation blood products

    International Nuclear Information System (INIS)

    Togashi, Kazue; Yamada, Keiko; Otake, Sachiko; Saito, Yukiko; Sugimura, Kazuhito; Takahashi, Hoyu

    1996-01-01

    Irradiation of blood products is highly effective in the prevention of transfusion-associated graft-versus-host disease (GVHD). In order to assess the safe storage period of irradiated blood products, serial changes in plasma K, red cell 2,3-diphosphoglycerate (2,3-DPG) and lactic acid concentrations of whole blood and M·A·P-added red cell concentrate (RC-M·A·P) during storage at 5degC were measured after irradiation with 137 Cs by IBL 437C (CIS bio international). Plasma K concentration did not change immediately after irradiation, but increased more rapidly and in a radiation dose-dependent manner in the irradiated products than nonirradiated products. The changes in red cell 2,3-DPG and lactic acid concentrations were not affected by irradiation but were rather dependent on the storage period after blood collection. Plasma K concentrations of whole blood and RC-M·A·P irradiated with 25 Gy increased at 5 and 3 days, respectively, to the K levels observed after the storage of nonirradiated products for 21 days. It is therefore recommended that whole blood be used within 5 days and RC-M·A·P within 3 days when stored after irradiation with 25 Gy. (author)

  8. Clinical and anatomic pathology effects of serial blood sampling in rat toxicology studies, using conventional or microsampling methods.

    Science.gov (United States)

    Caron, Alexis; Lelong, Christine; Bartels, T; Dorchies, O; Gury, T; Chalier, Catherine; Benning, Véronique

    2015-08-01

    As a general practice in rodent toxicology studies, satellite animals are used for toxicokinetic determinations, because of the potential impact of serial blood sampling on toxicological endpoints. Besides toxicological and toxicokinetic determinations, blood samples obtained longitudinally from a same animal may be used for the assessment of additional parameters (e.g., metabolism, pharmacodynamics, safety biomarkers) to maximize information that can be deduced from rodents. We investigated whether removal of up to 6 × 200 μL of blood over 24h can be applied in GLP rat toxicology studies without affecting the scientific outcome. 8 week-old female rats (200-300 g) were dosed for up to 1 month with a standard vehicle and subjected or not (controls) to serial blood sampling for sham toxicokinetic/ancillary determinations, using miniaturized methods allowing collection of 6 × 50, 100 or 200 μL over 24h. In-life endpoints, clinical pathology parameters and histopathology of organs sensitive to blood volume reduction were evaluated at several time points after completion of sampling. In sampled rats, minimal and reversible changes in red blood cell mass (maximally 15%) and subtle variations in liver enzymes, fibrinogen and neutrophils were not associated with any organ/tissue macroscopic or microscopic correlate. Serial blood sampling (up to 6 × 200 μL over 24h) is compatible with the assessment of standard toxicity endpoints in adult rats. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Performance on Paced Auditory Serial Addition Test and cerebral blood flow in multiple sclerosis

    NARCIS (Netherlands)

    D'haeseleer, M.; Steen, C.; Hoogduin, J. M.; van Osch, M. J. P.; Fierens, Y.; Cambron, M.; Koch, M. W.; De Keyser, J.

    BackgroundTo assess the relationship between performance on the Paced Auditory Serial Addition Test (PASAT) and both cerebral blood flow (CBF) and axonal metabolic integrity in normal appearing white matter (NAWM) of the centrum semiovale in patients with multiple sclerosis (MS). MethodsNormal

  10. SOFTWARE AND TECHNOLOGY FOR COLLECTING AND STORAGE SERIAL OBSERVATIONS OF THE ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    A. V. Tokarev

    2014-01-01

    Full Text Available Some aspects of the collecting and storage serial observations of the environment is considered. The paper considers the creation of a storage subsystem and climate data collection, which will enable users to perform data collection, integration, storage and analysis. Developed server data collector prototype implement basic functions of the program interface (API and administrative webinterface. Several data flows from different data sources is created – public sources of climate data, autonomous weather stations, information systems of monitoring. Work is underway to establish a means for effective access to observational data, services, reporting and analysis of information.

  11. Technical report: serial collections of placentomes during parturition in cattle and subsequent reproductive performance.

    Science.gov (United States)

    McNeel, Anthony K; Ondrak, Jeff D; Cushman, Robert A

    2013-05-01

    Placental separation is a complex physiological event in reproductive physiology and the underlying molecular mechanisms remain unclear. When comparing different experiments the timing of tissue collections is a significant consideration due to the variability in time between fetal expulsion and expulsion of the placenta (30 min to >24 h). This makes comparison of tissues samples across animals difficult and supports the need for serial tissue collections within animal. Additionally, the instrument most commonly used, a modified Richter-Resinsinger effeminator, for placentome collections is difficult to obtain and there are no data in the literature record regarding subsequent reproductive performance of animals subjected placentome collections. To facilitate continued research into the physiology behind placental separation, we designed an instrument from readily available components and performed serial transvaginal placentome collections in cattle. Three placentomes at 2-h intervals were collected after expulsion of the calf in 18 multiparous cows. There was no incidence of mortality and all cows resumed estrous after the procedure. Neither time from placentome collection nor age had a significant effect on pregnancy status at diagnosis (P > 0.05). These results demonstrate the viability of and utility of this device for collecting multiple placentomes in cattle.

  12. Data Collected in 1959 by English Research Vessels at Serial and Surface Hydrographic Stations (NODC Accession 6900852)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The present volume contains data collected in 1959 by English research vessels at serial and surface hydrographic stations. The data list are preceded by a number of...

  13. Relevance of EDTA carryover during blood collection.

    Science.gov (United States)

    Cadamuro, Janne; Felder, Thomas Klaus; Oberkofler, Hannes; Mrazek, Cornelia; Wiedemann, Helmut; Haschke-Becher, Elisabeth

    2015-07-01

    The order of draw is regarded as a preanalytical issue to prevent carryover of additives during blood collection. Our objective was to prove the theory of ethylenediaminetetraacetic acid (EDTA) carryover for a closed vacuum system and the influence of EDTA on concentrations of selected biomarkers. To test the carryover of EDTA, a blood collection with tripotassium EDTA (K3EDTA) and subsequent non-additive tubes was simulated using distilled water as substitute for blood. EDTA concentrations were measured by tandem mass spectrometry. Then we added increasing concentrations of EDTA to heparinized blood and measured routine biomarkers, thereby simulating a carryover of EDTA whole blood and pure EDTA, respectively. Additionally, we tested for EDTA contamination and biomarker alteration in samples collected from 10 healthy volunteers by a syringe with subsequent transfer into sample tubes. No EDTA contamination was detected in samples collected subsequent to a K3EDTA tube when adhering to guidelines of blood sampling. Magnesium, calcium, and potassium levels were altered by artificial K3EDTA whole-blood contamination as well as when adding 1 μL pure K3EDTA. Iron values were altered at EDTA concentrations of 4.4 mmol/L. All other parameters remained unaffected. A slight EDTA carryover was observed in syringe collection and subsequent transfer into EDTA and heparin tubes, however, without any biomarker alteration. An EDTA carryover during blood collection using a closed vacuum system is highly unlikely. Even if carryover of EDTA whole blood occurs, an absolute volume larger than 10 μL would be necessary to alter test results. However, contamination of samples with preloaded pure K3EDTA solution by severe neglect of current recommendations in blood collection may significantly alter testing results.

  14. Modeling and simulation of blood collection systems.

    Science.gov (United States)

    Alfonso, Edgar; Xie, Xiaolan; Augusto, Vincent; Garraud, Olivier

    2012-03-01

    This paper addresses the modeling and simulation of blood collection systems in France for both fixed site and mobile blood collection with walk in whole blood donors and scheduled plasma and platelet donors. Petri net models are first proposed to precisely describe different blood collection processes, donor behaviors, their material/human resource requirements and relevant regulations. Petri net models are then enriched with quantitative modeling of donor arrivals, donor behaviors, activity times and resource capacity. Relevant performance indicators are defined. The resulting simulation models can be straightforwardly implemented with any simulation language. Numerical experiments are performed to show how the simulation models can be used to select, for different walk in donor arrival patterns, appropriate human resource planning and donor appointment strategies.

  15. Umbilical Cord Blood: Counselling, Collection, and Banking.

    Science.gov (United States)

    Armson, B Anthony; Allan, David S; Casper, Robert F

    2015-09-01

    To review current evidence regarding umbilical cord blood counselling, collection, and banking and to provide guidelines for Canadian health care professionals regarding patient education, informed consent, procedural aspects, and options for cord blood banking in Canada. Selective or routine collection and banking of umbilical cord blood for future stem cell transplantation for autologous (self) or allogeneic (related or unrelated) treatment of malignant and non-malignant disorders in children and adults. Cord blood can be collected using in utero or ex utero techniques. Umbilical cord blood counselling, collection, and banking, education of health care professionals, indications for cord blood collection, short- and long-term risk and benefits, maternal and perinatal morbidity, parental satisfaction, and health care costs. Published literature was retrieved through searches of Medline and PubMed beginning in September 2013 using appropriate controlled MeSH vocabulary (fetal blood, pregnancy, transplantation, ethics) and key words (umbilical cord blood, banking, collection, pregnancy, transplantation, ethics, public, private). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. There were no date limits, but results were limited to English or French language materials. Searches were updated on a regular basis and incorporated in the guideline to September 2014. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, and national and international medical specialty societies. The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). Umbilical cord blood is a readily available source of hematopoetic stem cells used with increasing frequency as an alternative to

  16. Epidemiology of blood collection in France

    International Nuclear Information System (INIS)

    Lawson-Ayayi, S.; Salmi, L.R.

    1999-01-01

    The objectives of the cross-sectional study (EpiCoS) were to describe, at different stages, volunteers offering their blood, and to characterize various ways of collecting blood. From 15 September 1996 to 31 December 1996, individuals presenting at fixed or mobile sessions in one of 11 randomly selected blood banks were included after they had a medical examination. Variables studied were relative to type of collection, individuals, medical examination, patterns of blood letting, use of collected donations and if unused, reasons for discarding. Sixty four thousand and ninety two volunteers, aged 17-66 years old were included. The proportion of exclusion during medical examination was 10.8% (95% confidence interval (CI): 10.6-11.0%). Exclusions were more frequent among new volunteers and were mostly related to the safety of recipients. Most of the 57,003 donations were whole blood (94.0%) and collected in mobile sessions (89.9%). Five percent of collected donations were discarded; 3.5% (95% CI: 3.4-3.7%) of donations discarded for biological abnormalities, including 1.5% only for initial screen reactions to infectious disease markers (HBs antigen, anti-HBc antibodies, anti-HCV antibodies, anti-HIV antibodies, anti-HTLV antibodies, malaria antibodies and anti-syphilitic antibodies). The most frequent biological abnormality was a high alanine aminotransferase level. A follow-up of these indicators, within the French haemovigilance system, should allow further identification of risk factors and high-risk contexts, and planning means of optimizing blood collection in France

  17. The effect of serial data collection on the accuracy of electrical impedance tomography images

    International Nuclear Information System (INIS)

    Yerworth, Rebecca; Bayford, Richard

    2013-01-01

    There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use serial data collection hence data used to create a single image will have been collected at different times. This paper presents a study of the resulting image distortion, and proposes a method for correcting this lag in situations where the frame rate is insufficient to prevent significant image degradation. Significant correlation between the standard deviation of the time dependent reciprocity error and time delay dL e between the reciprocal electrode combinations was found for both adult and neonate data. This was reduced when the data was corrected for dL e . Original and corrected data was reconstructed with the GREIT algorithm and visible differences were found for the neonate data. Ideally EIT systems should be run at a frame rate of at least 50 times the frequency of the dominant and interesting physiological signals. Where this is not practical, the intra-frame system timings should be determined and lag corrected for. (paper)

  18. Ion suppression from blood collection devices

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo; Sejr Gothelf, Aase

    The aim of the study was to examine the variation in ion suppression in ultra high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS-MS) methods when using different blood collection devices. Three different methods measuring 18 antidepressants and antipsychotics in total were...... Terumo, S-monovette from Sarstedt, Vacuette from Greiner Bio-One and three BD Vacutainer serum tubes from BD. These seven different blood collection devices were used to withdraw blood from five healthy drug free donors (n=35) in random order. The samples were centrifuged and serum from each sample...... by UHPLC-MS-MS using three different gradients (Group I, II and III). The analytes in group I was measured on an Agilent 6460 mass spectrometer and group II and III were measured on an Agilent 6410 mass spectrometer both utilizing positive electrospray ionization. The experiments demonstrated significant...

  19. Serial transmission of human T-cell leukemia virus type I by blood transfusion in rabbits and its prevention by use of X-irradiated stored blood

    Energy Technology Data Exchange (ETDEWEB)

    Kotani, S.; Yoshimoto, S.; Yamato, K.; Fujishita, M.; Yamashita, M.; Ohtsuki, Y.; Taguchi, H.; Miyoshi, I.

    1986-06-15

    Human T-cell leukemia virus type I (HTLV-I) was serially transmitted for 5 passages from rabbit to rabbit by blood transfusion. The virus could be transmitted with 20 ml of whole blood or washed blood cell suspension (fresh or stored for 1-2 weeks at 4 degrees C) but not with cell-free plasma from seroconverted rabbits. Seroconversion occurred 2-4 weeks after blood transfusion and serum anti-HTLV-I titers ranged from 1:20 to 1:640 with the immunofluorescence assay. From transfusion recipients of the 1st to 4th passages, virus-producing cell lines were established by culturing lymphocytes in the presence of T-cell growth factor (TCGF). Three of the 4 cell lines became TCGF-independent after 2-12 months of continuous culture. Blood was transfused between rabbits of opposite sexes and the recipient origin of each cell line was determined by chromosome analysis. We also investigated the effect of X-irradiation (6,000 rad) on blood from seropositive rabbits. Seroconversion likewise occurred in rabbits transfused with blood that had been irradiated immediately before transfusion but not in rabbits transfused with blood that had been irradiated and stored for 1-2 weeks at 4 degrees C. Thus, our rabbit model shows that HTLV-I is serially transmissible by blood transfusion and that this can be prevented by irradiation of blood. The same procedure, therefore, may be useful for the prevention of transfusion-related transmission of HTLV-I in humans.

  20. Mechanisms of recovery from aphasia: evidence from serial xenon 133 cerebral blood flow studies

    International Nuclear Information System (INIS)

    Knopman, D.S.; Rubens, A.B.; Selnes, O.A.; Klassen, A.C.; Meyer, M.W.

    1984-01-01

    In 21 patients who suffered aphasia resulting from left hemisphere ischemic infarction, the xenon 133 inhalation cerebral blood flow technique was used to measure cerebral blood flow within 3 months and 5 to 12 months after stroke. In addition to baseline measurements, cerebral blood flow measurements were also carried out while the patients were performing purposeful listening. In patients with incomplete recovery of comprehension and left posterior temporal-inferior parietal lesions, greater cerebral blood flow occurred with listening in the right inferior frontal region in the late studies than in the early studies. In patients with nearly complete recovery of comprehension and without left posterior temporal-inferior parietal lesions, early listening studies showed diffuse right hemisphere increases in cerebral blood flow. Later listening studies in this latter patient group showed greater cerebral blood flow in the left posterior temporal-inferior parietal region. The study provides evidence for participation of the right hemisphere in language comprehension in recovering aphasics, and for later return of function in left hemisphere regions that may have been functionally impaired early during recovery

  1. Serial diffusion-weighted MRI correlates with clinical course and treatment response in children with intracranial pus collections

    International Nuclear Information System (INIS)

    Fanning, Noel F.; Laffan, Eoghan E.; Shroff, Manohar M.

    2006-01-01

    Accurate assessment of treatment response in children with intracranial pus collections is vital to guide appropriate therapy and reduce morbidity and mortality. To correlate serial MR-measurable changes in diffusion-weighted imaging (DWI) with clinical response to treatment. We retrospectively reviewed clinical notes, conventional MR sequences and DWI in eight children with intracranial pus collections. Trace DWI signal intensity and apparent diffusion coefficient (ADC) values were compared at three time points: at initial diagnosis (eight children, 13 collections), at follow-up during continued clinical infection (three children, sp collections), and at follow-up when clinical infection had resolved (seven children, 12 collections). At initial diagnosis all patients were septic and collections showed restricted diffusion (mean ADC 0.61±0.15 x 10 -3 mm 2 /s). Patients with persistent clinical sepsis at follow-up DWI had collections with persistent low ADC values (0.66±0.21 x 10 -3 mm 2 /s), significantly (P -3 mm 2 /s, P<0.01) compared both to patients with signs of continued sepsis and to normal gray matter values. Persistent restricted diffusion in pus collections correlates with continued sepsis. Treatment response is associated with clinical resolution of sepsis and ADC value elevation significantly above normal gray matter values. (orig.)

  2. Automatic collection of bovine blood samples | Hale | South African ...

    African Journals Online (AJOL)

    A technique is described which allows automatic collection of jugular venous blood from tethered cows. In this system, blood is pumped continuously from an intravenous cannula which has a double lumen while an anticoagulant is pumped through the second opening. Diluted blood is collected in a fraction collector which ...

  3. [Automated serial diagnosis of donor blood samples. Ergonomic and economic organization structure].

    Science.gov (United States)

    Stoll, T; Fischer-Fröhlich, C L; Mayer, G; Hanfland, P

    1990-01-01

    A comprehensive computer-aided administration-system for blood-donors is presented. Ciphered informations of barcode-labels allow the automatic and nevertheless selective pipetting of samples by pipetting-robots. Self-acting analysis-results are transferred to a host-computer in order to actualize a donor data-base.

  4. Posthumous Humans, Modern Vampires: Re-use, seriality, chorality of horror tropes in True Blood

    Directory of Open Access Journals (Sweden)

    Giulia Iannuzzi

    2016-06-01

    Full Text Available Why are some of us – inhabitants of increasingly dense and complex narrative ecosystems – compulsive spectators of horrors? What determines the liveliness of horror tropes that already have a long history of being used and re-used in narratives across different media, and what favors their being used incessantly on the small screen? This essay argues that in analyzing contemporary television series, we need to takes into account specific productive and narrative aspects, and (intra- and inter-textual elements as well as sociological ones, starting from the theoretical assumption that the fortune of horror series (and not only of them is in fact determined by those territories where these elements come together. As a case in point, this essay takes a look at True Blood, which was created in 2008 for HBO by Alan Ball, and came to an end with its seventh season in 2014. Positioned within the broader context of horror proliferation in contemporary television series, True Blood offers striking examples of the new mechanisms and distinction practices utilized by the television genre which is bringing about an increasing differentiation of audience segment.

  5. Collection and Transfusion of Blood in Jos University Teaching ...

    African Journals Online (AJOL)

    Objective: This study was embarked on to investigate the pattern of blood collection and transfusion in Jos University Teaching Hospital (JUTH), Jos between 2000 and 2005 in the face of the present human immunodeficiency virus (HIV) pandemic. Methodology: Blood bank records of blood donors and transfusions were ...

  6. Rethinking the Subscription Paradigm for Journals: Using Interlibrary Loan in Collection Development for Serials

    Science.gov (United States)

    Barton, Gail Perkins; Relyea, George E.; Knowlton, Steven A.

    2018-01-01

    Many librarians evaluate local Interlibrary Loan (ILL) statistics as part of collection development decisions concerning new subscriptions. In this study, the authors examine whether the number of ILL article requests received in one academic year can predict the use of those same journal titles once they are added as library resources. There is…

  7. Cocaine impairs serial-feature negative learning and blood-brain barrier integrity.

    Science.gov (United States)

    Davidson, Terry L; Hargrave, Sara L; Kearns, David N; Clasen, Matthew M; Jones, Sabrina; Wakeford, Alison G P; Sample, Camille H; Riley, Anthony L

    2018-05-10

    Previous research has shown that diets high in fat and sugar [a.k.a., Western diets (WD)] can impair performance of rats on hippocampal-dependent learning and memory problems, an effect that is accompanied by selective increases in hippocampal blood brain barrier (BBB) permeability. Based on these types of findings, it has been proposed that overeating of a WD (and its resulting obesity) may be, in part, a consequence of impairments in these anatomical substrates and cognitive processes. Given that drug use (and addiction) represents another behavioral excess, the present experiments assessed if similar outcomes might occur with drug exposure by evaluating the effects of cocaine administration on hippocampal-dependent memory and on the integrity of the BBB. Experiment 1 of the present series of studies found that systemic cocaine administration in rats also appears to have disruptive effects on the same hippocampal-dependent learning and memory mechanism that has been proposed to underlie the inhibition of food intake. Experiment 2 demonstrated that the same regimen of cocaine exposure that produced disruptions in learning and memory in Experiment 1 also produced increased BBB permeability in the hippocampus, but not in the striatum. Although the predominant focus of previous research investigating the etiologies of substance use and abuse has been on the brain circuits that underlie the motivational properties of drugs, the current investigation implicates the possible involvement of hippocampal memory systems in such behaviors. It is important to note that these positions are not mutually exclusive and that neuroadaptations in these two circuits might occur in parallel that generate dysregulated drug use in a manner similar to that of excessive eating. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Good practices in collecting umbilical cord and placental blood

    Directory of Open Access Journals (Sweden)

    Lauren Auer Lopes

    Full Text Available Abstract Objective: to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. Method: this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1 verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2 definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r and R(r. Results: while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. Conclusion: the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality.

  9. The Generation of Human Induced Pluripotent Stem Cells from Blood Cells: An Efficient Protocol Using Serial Plating of Reprogrammed Cells by Centrifugation

    Directory of Open Access Journals (Sweden)

    Youngkyun Kim

    2016-01-01

    Full Text Available Human induced pluripotent stem cells (hiPSCs have demonstrated great potential for differentiation into diverse tissues. We report a straightforward and highly efficient method for the generation of iPSCs from PBMCs. By plating the cells serially to a newly coated plate by centrifugation, this protocol provides multiple healthy iPSC colonies even from a small number of PBMCs. The generated iPSCs expressed pluripotent markers and differentiated into all three germ layer lineages. The protocol can also be used with umbilical cord blood mononuclear cells (CBMCs. In this study, we present a simple and efficient protocol that improved the yield of iPSCs from floating cells such as PBMCs and CBMCs by serial plating and centrifugation.

  10. Effects of blood collection conditions on ovarian cancer serum markers.

    Directory of Open Access Journals (Sweden)

    Jason D Thorpe

    2007-12-01

    Full Text Available Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies.We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer.Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.

  11. Biomonitoring of ciguatoxin exposure in mice using blood collection cards.

    Science.gov (United States)

    Bottein Dechraoui, M-Yasmine; Wang, Zhihong; Turquet, Jean; Chinain, Mireille; Darius, Taiana; Cruchet, Philippe; Radwan, Faisal F Y; Dickey, Robert W; Ramsdell, John S

    2005-09-01

    Ciguatera is a human food poisoning caused by consumption of tropical and subtropical fish that have, through their diet, accumulated ciguatoxins in their tissues. This study used laboratory mice to investigate the potential to apply blood collection cards to biomonitor ciguatoxin exposure. Quantitation by the neuroblastoma cytotoxicity assay of Caribbean ciguatoxin (C-CTX-1) spiked into mice blood was made with good precision and recovery. The blood collected from mice exposed to a sublethal dose of Caribbean ciguatoxic extract (0.59 ng/g C-CTX-1 equivalents) was analyzed and found to contain detectable toxin levels at least 12 h post-exposure. Calculated concentration varied from 0.25 ng/ml at 30 min post-exposure to 0.12 ng/ml at 12 h. A dose response mice exposure revealed a linear dose-dependent increase of ciguatoxin activity in mice blood, with more polar ciguatoxin congeners contributing to 89% of the total toxicity. Finally, the toxin measurement in mice blood exposed to toxic extracts from the Indian Ocean or from the Pacific Ocean showed that the blood collection card method could be extended to each of the three known ciguatoxin families (C-CTX, I-CTX and P-CTX). The low matrix effect of extracted dried-blood samples (used at 1:10 or 1:20 dilution) and the high sensitivity of the neuroblastoma assay (limit of detection 0.006 ng/ml C-CTX-1), determined that the blood collection card method is suitable to monitor ciguatoxin at sublethal doses in mice and opens the potential to be a useful procedure for fish screening, environmental risk assessment or clinical diagnosis of ciguatera fish poisoning in humans or marine mammals.

  12. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  13. An analysis of mobile whole blood collection labor efficiency.

    Science.gov (United States)

    Rose, William N; Dayton, Paula J; Raife, Thomas J

    2011-07-01

    Labor efficiency is desirable in mobile blood collection. There are few published data on labor efficiency. The variability in the labor efficiency of mobile whole blood collections was analyzed. We determined to improve our labor efficiency using lean manufacturing principles. Workflow changes in mobile collections were implemented with the goal of minimizing labor expenditures. To measure success, data on labor efficiency measured by units/hour/full-time equivalent (FTE) were collected. The labor efficiency in a 6-month period before the implementation of changes, and in months 1 to 6 and 7 to 12 after implementation was analyzed and compared. Labor efficiency in the 6-month period preceding implementation was 1.06 ± 0.4 units collected/hour/FTE. In months 1 to 6, labor efficiency declined slightly to 0.92 ± 0.4 units collected/hour/FTE (p = 0.016 vs. preimplementation). In months 7 to 12, the mean labor efficiency returned to preimplementation levels of 1.09 ±0.4 units collected/hour/FTE. Regression analysis correlating labor efficiency with total units collected per drive revealed a strong correlation (R(2) = 0.48 for the aggregate data from all three periods), indicating that nearly half of labor efficiency was associated with drive size. The lean-based changes in workflow were subjectively favored by employees and donors. The labor efficiency of our mobile whole blood drives is strongly influenced by size. Larger drives are more efficient, with diminishing returns above 40 units collected. Lean-based workflow changes were positively received by employees and donors. © 2011 American Association of Blood Banks.

  14. 76 FR 48167 - Agency Information Collection Activities; Proposed Collection; Comment Request; Blood...

    Science.gov (United States)

    2011-08-08

    ... requirements in the Agency's regulations and Form FDA 2830. DATES: Submit either electronic or written comments on the collection of information by October 7, 2011. ADDRESSES: Submit electronic comments on the... plasma donor centers, blood banks, certain transfusion services, other blood product manufacturers, and...

  15. The cost of blood collection in Greece: an economic analysis.

    Science.gov (United States)

    Fragoulakis, Vassilis; Stamoulis, Kostas; Grouzi, Elisabeth; Maniadakis, Nikolaos

    2014-07-01

    The goal of this study was to estimate the cost of production of 1 unit of blood from a National Health Service perspective in Greece. In agreement with guidelines, the cost of blood production in this study accounted only for the resources expended for collection, processing, laboratory testing, and storage. Hence, the costs associated with donor recruitment, pretransfusion preparation, transfusion administration, follow-up management of adverse events, and other long-term relevant costs were not taken into consideration. The indirect cost of blood donations for donors (productivity loss) was also considered. A questionnaire was used to collect data regarding personnel time, annual blood quantities collected, percentage of wastage, utilization of consumables, institutional overhead, information technology expenditure, medical equipment utilized, nuclear acid tests, and other factors. Data gathered by 53 hospitals across the country were assessed. A model was constructed with economic data collected by the National School of Public Health and the Ministry of Health. All data refer to the year 2013. The weighted mean direct cost of producing 1 unit of blood was estimated at €131.49 (SD, €22.12; minimum/maximum, €94.96-€239.20). The mean total indirect cost was estimated at €34 per unit of blood. The cost distribution was positively skewed (skewness, 1.642 [0.327]). The major cost component was the cost of personnel, accounting for 32.5% of total costs, and the average of blood unit wastage was estimated at 4.90%. There were no differences between the cost of producing 1 unit of blood in Athens compared with the rest of the country (Mann-Whitney test, P = 0.341). This study suggests that the cost of producing 1 unit of blood is not insignificant. These figures need to be complemented with those concerning the cost of transfusion to have a complete picture of producing and using 1 unit of blood locally. Copyright © 2014 Elsevier HS Journals, Inc. All

  16. 21 CFR 864.6150 - Capillary blood collection tube.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Capillary blood collection tube. 864.6150 Section 864.6150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6150 Capillary...

  17. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  18. Studies on the transmission of malignant catarrhal fever in experimental animals: A serial infection of cattle and buffalo by means of whole blood inoculation

    Directory of Open Access Journals (Sweden)

    Agus Wiyono

    1999-12-01

    Full Text Available Malignant catarrhal fever (MCF is a fatal disease especially affecting cattle and buffaloes. A study on the serial blood transmission of MCF was conducted by injecting whole blood of MCF animals into 9 experimental animals. Diagnosis of MCF was based on the clinico-pathological fmdings and polymerase chain reaction (PCR test. The disease has successfully, been achieved in six animals of three Bali cattle and three buffaloes but not in a Bali-cross breed and two Bos indicus (Ongole cattle. Wide range of clinical signs and gross-pathological features were observed. The study showed the degree of susceptibility of experimental animals: Bali cattle and buffalo were highly susceptible (3 out of 3 affected with MCF, Bali-cross breed and Bos indicus (Ongole cattle seemed not susceptible to whole blood experimental transmission. It shows that when Bali cattle acted as inoculum donor, buffalo tended to be clinically more severe than Bali cattle. On the other hand, when buffalo acted as inoculum donor, Bali cattle suffered from MCF more severe than buffalo. The diagnosis of MCF by histopathological examination and the PCR test bad positive correlation (100% in the first experiment, while in the second experiment the PCR test tends to be more sensitive. Based on the restriction endonuclease (RE test, the MCF causal agent in this study appeared to be genetically similar in each case. It is concluded that the serial experimental transmission of MCF by means of whole blood inoculation has been successfully achieved in Bali cattle and buffalo but not in Bali-cross breed and Ongole cattle, and there is a positive correlation between the PCR test and histopathological examination with the PCR test tends to be more sensitive.

  19. Investigating the impact of blood pressure increase to the brain using high resolution serial histology and image processing

    Science.gov (United States)

    Lesage, F.; Castonguay, A.; Tardif, P. L.; Lefebvre, J.; Li, B.

    2015-09-01

    A combined serial OCT/confocal scanner was designed to image large sections of biological tissues at microscopic resolution. Serial imaging of organs embedded in agarose blocks is performed by cutting through tissue using a vibratome which sequentially cuts slices in order to reveal new tissue to image, overcoming limited light penetration encountered in microscopy. Two linear stages allow moving the tissue with respect to the microscope objective, acquiring a 2D grid of volumes (1x1x0.3 mm) with OCT and a 2D grid of images (1x1mm) with the confocal arm. This process is repeated automatically, until the entire sample is imaged. Raw data is then post-processed to re-stitch each individual acquisition and obtain a reconstructed volume of the imaged tissue. This design is being used to investigate correlations between white matter and microvasculature changes with aging and with increase in pulse pressure following transaortic constriction in mice. The dual imaging capability of the system allowed to reveal different contrast information: OCT imaging reveals changes in refractive indices giving contrast between white and grey matter in the mouse brain, while transcardial perfusion of FITC or pre-sacrifice injection of Evans Blue shows microsvasculature properties in the brain with confocal imaging.

  20. Awareness of cord blood collection and the impact on banking.

    Science.gov (United States)

    Bhandari, Rusha; Lindley, Amy; Bhatla, Deepika; Babic, Aleksandar; Mueckl, Kathy; Rao, Rakesh; Brooks, Paula; Geiler, Vicki; Gross, Gilad; Al-Hosni, Mohamad; Shenoy, Shalini

    2017-07-01

    Umbilical cord blood (UCB) is an important source of hematopoietic stem cells for transplantation especially in minority populations with limited chances of finding a histocompatible volunteer donor in the registry. UCB has the advantages of early availability, successful outcomes despite some histocompatibility mismatch, and low incidence of chronic graft-versus-host disease. Public cord blood banks that disseminate UCB products for transplant depend on voluntary donation at participating hospitals and obstetrical providers for collection. Using survey questionnaires, we evaluated attitudes toward UCB donation, the frequency of donation, and provider opinions on UCB collection in the greater St. Louis metropolitan area that caters to minority ethnicities in significant numbers. Our data suggest that nervousness and lack of information regarding the donation and utility of the product were ubiquitous reasons for not donating. Additionally, irrespective of age or level of education, women relied on healthcare providers for information regarding UCB donation. Providers reported primarily time constraints to discussing UCB donation at prenatal visits (54%). Of the interviewees, 62% donated UCB. Fallout due to refusal or preferring private banking was miniscule. These results suggest that dedicated personnel focused on disseminating information, obtaining consent, and collecting the UCB product at major hospitals can enrich cord blood banks especially with minority cords. Sustained and focused efforts could improve upon a relatively high wastage rate and ensure a robust supply of UCB products at local public banks. © 2017 Wiley Periodicals, Inc.

  1. Impact of blood collection and processing on peripheral blood gene expression profiling in type 1 diabetes.

    Science.gov (United States)

    Yip, Linda; Fuhlbrigge, Rebecca; Atkinson, Mark A; Fathman, C Garrison

    2017-08-18

    The natural history of type 1 diabetes (T1D) is challenging to investigate, especially as pre-diabetic individuals are difficult to identify. Numerous T1D consortia have been established to collect whole blood for gene expression analysis from individuals with or at risk to develop T1D. However, with no universally accepted protocol for their collection, differences in sample processing may lead to variances in the results. Here, we examined whether the choice of blood collection tube and RNA extraction kit leads to differences in the expression of genes that are changed during the progression of T1D, and if these differences could be minimized by measuring gene expression directly from the lysate of whole blood. Microarray analysis showed that the expression of 901 genes is highly influenced by sample processing using the PAXgene versus the Tempus system. These included a significant number of lymphocyte-specific genes and genes whose expression has been reported to differ in the peripheral blood of at-risk and T1D patients compared to controls. We showed that artificial changes in gene expression occur when control and T1D samples were processed differently. The sample processing-dependent differences in gene expression were largely due to loss of transcripts during the RNA extraction step using the PAXgene system. The majority of differences were not observed when gene expression was measured in whole blood lysates prepared from blood collected in PAXgene and Tempus tubes. We showed that the gene expression profile of samples processed using the Tempus system is more accurate than that of samples processed using the PAXgene system. Variation in sample processing can result in misleading changes in gene expression. However, these differences can be minimized by measuring gene expression directly in whole blood lysates.

  2. Laparoscopic Technique for Serial Collection of Para-Colonic, Left Colic, and Inferior Mesenteric Lymph Nodes in Macaques.

    Directory of Open Access Journals (Sweden)

    Jeremy Smedley

    Full Text Available Unlike peripheral lymph nodes (PLN, the mesenteric lymph nodes (MLN draining the gastrointestinal (GI tract are exposed to microbes and microbial products from the intestines and as such, are immunologically distinct. GI draining (MLN have also been shown to be sites of early viral replication and likely impact early events that determine the course of HIV infection. They also are important reservoir sites that harbor latently-infected cells and from which the virus can emerge even after prolonged combination antiretroviral therapy (cART. Changes in the microbial flora and increased permeability of the GI epithelium associated with lentiviral infection can impact the gut associated lymphoid tissue (GALT and induce changes to secondary lymphoid organs limiting immune reconstitution with cART. Nonhuman primate models for AIDS closely model HIV infection in humans and serial sampling of the GALT and associated secondary lymphoid organs in this model is crucial to gain a better understanding of the critical early events in infection, pathogenesis, and the role of immune responses or drugs in controlling virus at these sites. However, current techniques to sample GI draining (MLN involve major surgery and/or necropsy, which have, to date, limited the ability to investigate mechanisms mediating the initiation, persistence and control of infection in this compartment. Here, we describe a minimally invasive laparoscopic technique for serial sampling of these sites that can be used with increased sampling frequency, yields greater cell numbers and immune cell subsets than current non-invasive techniques of the GALT and reduces the potential for surgical complications that could complicate interpretation of the results. This procedure has potential to facilitate studies of pathogenesis and evaluation of preventive and treatment interventions, reducing sampling variables that can influence experimental results, and improving animal welfare.

  3. Blood collection and the labile blood components: what should the regulators ask for?

    Science.gov (United States)

    Maniatis, A; Adamides, E

    1998-01-01

    Efforts to promote the quality and safety of blood collection are underway in most European Union (EU) member states but the level of quality management continues to differ significantly not only between countries but also among Blood Collection Establishments (BCE's) within a country. The European Commission has asked for blood safety and self-sufficiency in the Community and has initiated action in this direction. What is sought is harmonization of practices in the transfusion chain but such cannot be accomplished solely through recommendations and directives given the sociocultural and economic differences among EU member states. Active support for the development of common standards and a common quality system as well as an inspection and accreditation system would certainly help. The goal of self-sufficiency should certainly be emphasized but may be difficult to achieve, given the unpredictability of factors that may affect demand and supply. Through bipartisan initiatives however, between the USA and EU, consensus regarding the issue of blood safety, could be reached.

  4. An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System.

    Science.gov (United States)

    George, Paul E; Vidal, Julio; Garcia, Patricia J

    2016-05-01

    Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Every Peruvian blood bank was evaluated by MINSA from 2007-2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product.

  5. Effect of serial-day exposure to nitrogen dioxide on airway and blood leukocytes and lymphocyte subsets

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, C.; Chen, L.L.; Erle, D.J.; Balmes, J.R. [Univ. of California, Lung Biology Center and Center for Occupational and Environmental Health, San Francisco, CA (United States); Christian, D.L.; Welch, B.S.; Dunham, E. [Univ. of California, Lung Biology Center, San Francisco, CA (United States); Kleinman, M.T. [Univ. of California, Dept. of Community and Environmental Medicine, Irvine, CA (United States)

    2000-07-01

    Nitrogen dioxide (NO{sub 2}) is a free radical-producing oxidant gas. Inhalation of NO2 could cause airway inflammation, and decrease immune function. This experiment tested the hypothesis that exposure to NO{sub 2} would: (1) increase leukocytes in bronchoalveolar lavage (BAL); and (2) change the distribution of lymphocyte subsets and activation in BAL and peripheral blood (PB). Using a counter-balanced, repeated-measures design, 15 healthy volunteers were exposed to filtered air (FA) or 2.0 parts per million NO{sub 2} for 4 h.day{sup -1} (4 x 30 min of exercise), for three consecutive days. Bronchoscopy was performed 18 h following each exposure set, and PB was drawn pre-exposure and pre-bronchoscopy. Flow cytometry was used to enumerate lymphocyte subsets and activation makers in BAL and PB. In the bronchial fraction, there was an increase in the percentage of neutrophils following NO2 exposure compared to FA (median (interquartile range): 10.6 (4.8. 17.2)% versus 5.3 (2.5-8.3)%; p=0.005). In the BAL, there was a decrease in the percentage of T-helper cells following NO{sub 2} exposure compared to FA (55.9 (40.8-62.7)% versus 61.6 (52.6-65.2)%; p=0.022). For PB, there were no between-condition differences in any leukocyte or lymphocyte subsets, or activation. In conclusion exposure to nitrogen dioxide results in bronchial inflammation and a minimal change in bronchoalveolar lavage T-helper cells, and no changes in peripheral blood cells. (au)

  6. Good practices in collecting umbilical cord and placental blood.

    Science.gov (United States)

    Lopes, Lauren Auer; Bernardino, Elizabeth; Crozeta, Karla; Guimarães, Paulo Ricardo Bittencourt

    2016-08-18

    to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1) verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2) definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r) and R(r). while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality. identificar fatores relacionados à qualidade das amostras do sangue de cordão umbilical e placentário e definir boas práticas para sua coleta em um banco público de sangue de cordão umbilical e placentário. pesquisa descritiva, abordagem quantitativa, realizada em um banco público de sangue de cordão umbilical e placentário, desenvolvida em duas etapas: 1) verificação dos fatores obstétricos, neonatais e operacionais, obtidos por coleta em instrumento próprio e observação não participante; 2) definição das boas práticas, por meio do agrupamento de não-conformidades observadas antes, durante e após a coleta do sangue. Os dados foram analisados por meio da estatística descritiva, utilizando-se dos softwares Statistica(r) e R(r). houve

  7. Cortisol and prolactin concentrations during repeated blood sample collection from freely moving, mouse-sized mammals (Phodopus spp.).

    Science.gov (United States)

    Reburn, C J; Wynne-Edwards, K E

    2000-04-01

    Validation of a method for obtaining blood samples that does not change cortisol or prolactin concentrations yet allows serial blood samples to be collected from animals under anesthesia, without prior handling, from freely interacting social groups of small mammals. Results from five experiments are reported. Male dwarf hamsters (Phodopus spp.) were housed in modified home cages under continuous flow of compressed air that could be switched to isoflurane in O2 vehicle without approaching the cages. Dwarf hamsters respond to manual restraint with behavioral distress and increase in the concentration of the dominant glucocorticoid, cortisol, and decrease in prolactin concentration. Both effects are evident within one minute. In contrast, when this new method was used, neither cortisol nor prolactin changed in response to repeated sample collection (up to 8 successive samples at 2 hour intervals), prolonged isoflurane exposure, or substantial blood volume reduction (30%). Prolactin concentration was suppressed and cortisol concentration was increased in response to stimuli from other hamsters tested without anesthesia. Suppression of prolactin concentration was graded in response to the degree of stress and equaled the pharmacologic reduction caused by bromocryptine mesylate (50 microg of CB154 x 3 days). The technique is superior to alternatives for studies of behavioral endocrinology of freely interacting small mammals.

  8. Quantification of serial changes in cerebral blood volume and metabolism in patients with recurrent glioblastoma undergoing antiangiogenic therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stadlbauer, Andreas, E-mail: andi@nmr.at [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen (Germany); Department of Radiology and Nuclear Medicine, Medical University Vienna, Währinger Gürtel 18-20, A-1097 Vienna (Austria); Pichler, Petra [First Department of Internal Medicine, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Poelten (Austria); Karl, Marianne [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Brandner, Sebastian [Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, D-91054 Erlangen (Germany); Lerch, Claudia [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria); Renner, Bertold [Institute of Experimental and Clinical Pharmacology and Toxicology, University of Erlangen-Nürnberg, Erlangen (Germany); Heinz, Gertraud [Institute of Medical Radiology, University Clinic of St. Pölten, Propst Führer-Straße 4, A-3100 St. Pölten (Austria)

    2015-06-15

    Highlights: • Antiangiogenic therapy can lead to a decreased in CBV in normal brain tissue. • Responding and pseudoresponding lesions to AAT showed a similar CBV decrease. • Cho and NAA allowed for a distinction of responding and pseudoresponding lesions. • Cr ratios are not suited for evaluation of antiangiogenic therapy response. • Responders to AAT may have an increased risk for remote progression of the GBM. - Abstract: Objectives: To evaluate the usefulness of quantitative advanced magnetic resonance imaging (MRI) methods for assessment of antiangiogenic therapy (AAT) response in recurrent glioblastoma multiforme (GBM). Methods: Eighteen patients with recurrent GBM received bevacizumab and 18 patients served as control group. Baseline MRI and two follow-up examinations were acquired every 3–5 months using dynamic susceptibility-weighted contrast (DSC) perfusion MRI and {sup 1}H-MR spectroscopic imaging ({sup 1}H-MRSI). Maps of absolute cerebral blood volume (aCBV) were coregistered with choline (Cho) and N-acetyl-aspartate (NAA) concentrations and compared to usually used relative parameters as well as controls. Results: Perfusion significantly decreased in responding and pseudoresponding GBMs but also in normal appearing brain after AAT onset. Cho and NAA concentrations were superior to Cr-ratios in lesion differentiation and showed a clear gap between responding and pseudoresponding lesions. Responders to AAT exceptionally frequently (6 out of 8 patients) showed remote GBM progression. Conclusions: Quantification of CBV reveals changes in normal brain perfusion due to AAT, which were not described so far. DSC perfusion MRI seems not to be suitable for differentiation between response and pseudoresponse to AAT. However, absolute quantification of brain metabolites may allow for distinction due to a clear gap at 6–9 months after therapy onset.

  9. Optimal method for collection of umbilical cord blood: an Egyptian trial for a public cord blood bank.

    Science.gov (United States)

    Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A

    2015-06-01

    Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.

  10. Pharmacokinetic Profiling of Conjugated Therapeutic Oligonucleotides: A High-Throughput Method Based Upon Serial Blood Microsampling Coupled to Peptide Nucleic Acid Hybridization Assay.

    Science.gov (United States)

    Godinho, Bruno M D C; Gilbert, James W; Haraszti, Reka A; Coles, Andrew H; Biscans, Annabelle; Roux, Loic; Nikan, Mehran; Echeverria, Dimas; Hassler, Matthew; Khvorova, Anastasia

    2017-12-01

    Therapeutic oligonucleotides, such as small interfering RNAs (siRNAs), hold great promise for the treatment of incurable genetically defined disorders by targeting cognate toxic gene products for degradation. To achieve meaningful tissue distribution and efficacy in vivo, siRNAs must be conjugated or formulated. Clear understanding of the pharmacokinetic (PK)/pharmacodynamic behavior of these compounds is necessary to optimize and characterize the performance of therapeutic oligonucleotides in vivo. In this study, we describe a simple and reproducible methodology for the evaluation of in vivo blood/plasma PK profiles and tissue distribution of oligonucleotides. The method is based on serial blood microsampling from the saphenous vein, coupled to peptide nucleic acid hybridization assay for quantification of guide strands. Performed with minimal number of animals, this method allowed unequivocal detection and sensitive quantification without the need for amplification, or further modification of the oligonucleotides. Using this methodology, we compared plasma clearances and tissue distribution profiles of two different hydrophobically modified siRNAs (hsiRNAs). Notably, cholesterol-hsiRNA presented slow plasma clearances and mainly accumulated in the liver, whereas, phosphocholine-docosahexaenoic acid-hsiRNA was rapidly cleared from the plasma and preferably accumulated in the kidney. These data suggest that the PK/biodistribution profiles of modified hsiRNAs are determined by the chemical nature of the conjugate. Importantly, the method described in this study constitutes a simple platform to conduct pilot assessments of the basic clearance and tissue distribution profiles, which can be broadly applied for evaluation of new chemical variants of siRNAs and micro-RNAs.

  11. The utility and cost-effectiveness of serial complete blood count monitoring in patients receiving radiation therapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Blank, Kenneth; Cascardi, Michelle; Kao, Gary D.

    1997-01-01

    3 or platelets less than 100,000 cells/mm 3 at any time. A survey of area clinical laboratories revealed total charges ranging from $22 to 45 per CBC (mean = $35) performed on patients referred. Conclusions: These results suggest that patients with prostate cancer who begin radiotherapy with a normal baseline CBC can be safely followed with weekly clinical assessments and a single followup CBC at week 4 or 5 of treatment or as indicated by symptoms. This strategy would identify in a timely manner all patients with significant drops in their hemoglobin levels necessitating further intervention and will result in a cost savings approaching $30,000 per 100 treated patients, while sparing patient discomfort and staff resources needed to track test results. Further research on the cost-effectiveness and utility of serial blood tests in patients receiving radiation therapy are needed, and has the enormous potential of reducing unnecessary costs and patient discomfort in a era of limited resources

  12. New aspects of blood collection and handling procedures for the assessment of t-PA and PAI-1 variables after the introduction of acid blood collection

    NARCIS (Netherlands)

    Meijer, P.; Kret, R.; Bloetjes, P.T.M.; Rosen, S.; Kluft, C.

    1994-01-01

    Blood collection and handling procedures for t-PA activity have thusfar been rather strict and have restrained the use in clinical practice. We evaluated simplifications in the procedures for specifically the use of Stabilyte® vacutainers with respect to time before centrifugation of blood, storage

  13. 21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Empty container for the collection and processing of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products...

  14. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  15. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  16. 77 FR 10756 - Proposed Collection; Comment Request; Opinions and Perspectives About the Current Blood Donation...

    Science.gov (United States)

    2012-02-23

    ... with Men. Type of Information Collection Request: New. Need and Use of Information Collection: The... prevalence of compliance and non-compliance with the current MSM policy and assessing motivations for blood... donate blood. Frequency of Response: Once. Affected Public: Individuals. Type of Respondents: Males 18...

  17. Monitoring of benzene-induced hematotoxicity in mice by serial leukocyte counting using a microcavity array.

    Science.gov (United States)

    Hosokawa, Masahito; Asami, Marie; Yoshino, Tomoko; Tsujimura, Noriyuki; Takahashi, Masayuki; Nakasono, Satoshi; Tanaka, Tsuyoshi; Matsunaga, Tadashi

    2013-02-15

    Monitoring of hematotoxicity, which requires serial blood collection, is difficult to carry out in small animals due to a lack of non-invasive, individual animal-appropriate techniques that enable enumeration of leukocyte subsets from limited amounts of whole blood. In this study, a microfluidic device equipped with a microcavity array that enables highly efficient separation of leukocytes from submicroliters of whole blood was applied for hematotoxicity monitoring in mice. The microcavity array can specifically separate leukocytes from whole blood based on differences in the size and deformability between leukocytes and other blood cells. Mouse leukocytes recovered on aligned microcavities were continuously processed for image-based immunophenotypic analysis. Our device successfully recovered almost 100% of mouse leukocytes in 0.1 μL of whole blood without the effect of serial blood collection such as changes in body weight and total leukocyte count. We assessed benzene-associated hematotoxicity in mice using this system. Mice were administered with benzene once daily and the depression of leukocyte numbers induced in individual mice was successfully monitored from tail vein blood collected every other day for 2 weeks. Serial monitoring of the leukocyte number in individual mice will contribute to the understanding of hematotoxicity and reduction of the number of animal experiment trials. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Evaluation Of Blood Collected From Clinically Diagnosed Typhoid ...

    African Journals Online (AJOL)

    Blood culture revealed that 216 (42.8%) bacterial pathogens were isolated from the Widal positive patients yielded out of which 101 (46.8%) isolates were of ... fatal illness such as malaria and other parasitaemia, non-typhoid salmonellosis, endocarditis and other gastro-intestinal infections may have been responsible.

  19. Evaluation of two different protocols for peripheral blood stem cell collection with the Fresenius AS 104 blood cell separator.

    Science.gov (United States)

    Menichella, G; Lai, M; Pierelli, L; Vittori, M; Serafini, R; Ciarli, M; Foddai, M L; Salerno, G; Sica, S; Scambia, G; Leone, G; Bizzi, B

    1997-01-01

    Reconstitution of hematopoiesis by means of peripheral blood stem cells is a valid alternative to autologous bone marrow transplantation. The aim of this investigation was to increase the efficiency of collection of circulating blood progenitor cells and to obtain a purer product for transplant. We carried out leukapheresis procedures with the Fresenius AS 104 blood cell separator, using two different protocols, the previously used PBSC-LYM and a new mononuclear cell collection program. Both programs were highly effective in collecting mononuclear cells (MNC) and CD34+ cells. Some differences were found, especially regarding MNC yield and efficiencies. There are remarkable differences in the efficiency of collection of CD34+ cells (62.38% with the new program as opposed to 31.69% with the older one). Linear regression analysis showed a negative correlation between blood volume processed and MNC efficiency only for the PBSC-LYM program. Differences were also observed in the degree of inverse correlation existing in both programs between patients' white blood cell precount and MNC collection efficiency. The inverse correlation was stronger for the PBSC-LYM program. Seven patients with solid tumors and hematologic malignancies received high dose chemotherapy and were subsequently transplanted with peripheral blood stem cells collected using the new protocol. All patients obtained a complete and stable engraftment with the reinfusion product collected with one or two leukapheresis procedures. High efficiencies and yields were observed in the new protocol for MNC and CD34+ cells. These were able to effect rapid and complete bone marrow recovery after myeloablative chemotherapy.

  20. Study on chromosome aberrations test determinated by micro-whole blood culture in vacuum blood collection tube

    International Nuclear Information System (INIS)

    Zhong Zhihong; Han Fang'an; Ge Qinjuan; Wu Xiao; Chen Juan

    2006-01-01

    Objective: To develop an easier and efficient method of culturing the chromosome and analyzing the aberrations in peripheral lymphocytes. Methods: Micro whole was cultured for 54 hours in home-made vacuum blood collection tube, and then collection, slice-making, microscopy detection for the chromosome aberrations was done. The difference of the results was analysed by comparing with the common method. Results: For 60 radiologists and 30 contrasts, the chromosome aberrations in peripheral lymphocytes were examed by this system, the lymphocytes and chromosome were clear and alive and easier to analyse. Compared with the common method, there was no significantly difference between the two analyzing results. Conclusion: The chromosome aberrations test by micro whole blood culture in vacuum blood collection tube is easier and efficient, and is worthy of being widely popularized. (authors)

  1. Developments in Serials: 1977

    Science.gov (United States)

    James, John R.

    1978-01-01

    Discusses issues and developments relating to several aspects of serials, including economics and acquisitions; bibliographic control; automation; education; serials literature and bibliographies; and copyrights. A bibliography is included. (Author/MBR)

  2. Decreasing Serial Cost Sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Østerdal, Lars Peter

    The increasing serial cost sharing rule of Moulin and Shenker [Econometrica 60 (1992) 1009] and the decreasing serial rule of de Frutos [Journal of Economic Theory 79 (1998) 245] have attracted attention due to their intuitive appeal and striking incentive properties. An axiomatic characterization...... of the increasing serial rule was provided by Moulin and Shenker [Journal of Economic Theory 64 (1994) 178]. This paper gives an axiomatic characterization of the decreasing serial rule...

  3. Decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Østerdal, Lars Peter Raahave

    2009-01-01

    The increasing serial cost sharing rule of Moulin and Shenker (Econometrica 60:1009-1037, 1992) and the decreasing serial rule of de Frutos (J Econ Theory 79:245-275, 1998) are known by their intuitive appeal and striking incentive properties. An axiomatic characterization of the increasing serial...... rule was provided by Moulin and Shenker (J Econ Theory 64:178-201, 1994). This paper gives an axiomatic characterization of the decreasing serial rule....

  4. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members.

    Science.gov (United States)

    Närhi, M; Natri, O; Desbois, I; Kinggaard Holm, D; Galea, G; Aranko, K; Korhonen, M; Nordstrom, K

    2013-11-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization. An online questionnaire was used for data collection in 2011, and 43 replies were received covering 71 product answers from 13 countries. Estimated percentages of tissue and cell banking covered by EBA member blood banks as a proportion of all collections of each individual country varied markedly. There were also major differences in the amounts of products collected and discarded and in proportions tissues provided for grafting. However, discarding of certain collections also reflects the practice of increasing the likelihood of the very best units being used for transplantation. Harmonization of possible practices should focus on matching supply with demand and on identifying the most efficient operators. This could allow for the development of practices for minimizing unnecessary collections. © 2013 International Society of Blood Transfusion.

  5. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  6. Cost-effectiveness of alternative changes to a national blood collection service.

    Science.gov (United States)

    Willis, S; De Corte, K; Cairns, J A; Zia Sadique, M; Hawkins, N; Pennington, M; Cho, G; Roberts, D J; Miflin, G; Grieve, R

    2018-05-16

    To evaluate the cost-effectiveness of changing opening times, introducing a donor health report and reducing the minimum inter-donation interval for donors attending static centres. Evidence is required about the effect of changes to the blood collection service on costs and the frequency of donation. This study estimated the effect of changes to the blood collection service in England on the annual number of whole-blood donations by current donors. We used donors' responses to a stated preference survey, donor registry data on donation frequency and deferral rates from the INTERVAL trial. Costs measured were those anticipated to differ between strategies. We reported the cost per additional unit of blood collected for each strategy versus current practice. Strategies with a cost per additional unit of whole blood less than £30 (an estimate of the current cost of collection) were judged likely to be cost-effective. In static donor centres, extending opening times to evenings and weekends provided an additional unit of whole blood at a cost of £23 and £29, respectively. Introducing a health report cost £130 per additional unit of blood collected. Although the strategy of reducing the minimum inter-donation interval had the lowest cost per additional unit of blood collected (£10), this increased the rate of deferrals due to low haemoglobin (Hb). The introduction of a donor health report is unlikely to provide a sufficient increase in donation frequency to justify the additional costs. A more cost-effective change is to extend opening hours for blood collection at static centres. © 2018 The Authors. Transfusion Medicine published by John Wiley & Sons Ltd on behalf of British Blood Transfusion Society.

  7. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. The Generation of Human Induced Pluripotent Stem Cells from Blood Cells: An Efficient Protocol Using Serial Plating of Reprogrammed Cells by Centrifugation

    OpenAIRE

    Youngkyun Kim; Yeri Alice Rim; Hyoju Yi; Narae Park; Sung-Hwan Park; Ji Hyeon Ju

    2016-01-01

    Human induced pluripotent stem cells (hiPSCs) have demonstrated great potential for differentiation into diverse tissues. We report a straightforward and highly efficient method for the generation of iPSCs from PBMCs. By plating the cells serially to a newly coated plate by centrifugation, this protocol provides multiple healthy iPSC colonies even from a small number of PBMCs. The generated iPSCs expressed pluripotent markers and differentiated into all three germ layer lineages. The protocol...

  9. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  10. Remote blood collection in reindeer (Rangifer tarandus tarandus L: a preliminary study

    Directory of Open Access Journals (Sweden)

    E. Wiklund

    1994-12-01

    Full Text Available Automatic blood sampling equipment (ABSE was used successfully to collect blood samples from two reindeer. During blood sampling, two methods of restraint were applied which caused no short term changes in plasma concentrations of urea, aspartate aminotransferase, alanine aminotransferase or total protein. Plasma Cortisol concentrations were significantly elevated by the two restraint techniques. The value of ABSE in studies of stress in reindeer is discussed.

  11. Namibia's transition from whole blood-derived pooled platelets to single-donor apheresis platelet collections

    NARCIS (Netherlands)

    Pitman, John P.; Basavaraju, Sridhar V.; Shiraishi, Ray W.; Wilkinson, Robert; von Finckenstein, Bjorn; Lowrance, David W.; Marfin, Anthony A.; Postma, Maarten; Mataranyika, Mary; Smit Sibinga, Cees Th.

    BACKGROUNDFew African countries separate blood donations into components; however, demand for platelets (PLTs) is increasing as regional capacity to treat causes of thrombocytopenia, including chemotherapy, increases. Namibia introduced single-donor apheresis PLT collections in 2007 to increase PLT

  12. 77 FR 35408 - Proposed Collection; Comment Request: Opinions and Perspectives About the Current Blood Donation...

    Science.gov (United States)

    2012-06-13

    ... Policy for Men Who Have Sex with Men. Type of Information Collection Request: New. Need and Use of... prevalence of compliance and non-compliance with the current MSM policy and assessing motivations for blood... donate blood. Frequency of Response: Once. Affected Public: Individuals. Type of Respondents: Males 18...

  13. Early intraoperative blood collection does not affect complete blood counts, von Willebrand factor or factor VIII levels in normal children.

    Science.gov (United States)

    Darwish, Hanni; Mundell, Gillianne; Engen, Dale; Lillicrap, David; Silva, Mariana; James, Paula

    2011-01-01

    Obtaining blood from children for research studies can be difficult, particularly for controls. One solution is to obtain samples during elective surgery; however, consideration must be given to the potential effects of the timing of phlebotomy. Ten children were recruited and phlebotomy was carried out during a preoperative clinic visit and intraoperatively immediately after the induction of anesthesia but before the start of surgery. CBCs, VWF, and FVIII levels were measured at both time points and no significant differences were seen. This negative result may be beneficial to pediatric research by suggesting that early intraoperative blood collection for controls does not affect the results.

  14. Effect of blood collection technique in mice on clinical pathology parameters.

    Science.gov (United States)

    Schnell, Michael A; Hardy, Christine; Hawley, Melanie; Propert, Kathleen Joy; Wilson, James M

    2002-01-01

    A study was conducted in normal healthy C57BL/6 mice to determine the effect of method of blood collection on clinical pathology parameters and to provide value ranges for these parameters. Males and females were used and were randomly assigned to treatment groups based upon phlebotomy method. The blood was collected using one of four methods: intracardiac (IC), a single attempt at collection from the caudal vena cava (VC), collection from the caudal vena cava with collection of any extravasated blood from the peritoneum (MC), or retroorbital phlebotomy (RO). Evaluation of blood and serum samples was conducted for a number of serum biochemistries including liver function tests and complete blood count with differentials and platelet counts. Female mice demonstrated higher values for red blood cell number, hemoglobin (p values for platelet counts, specific white blood cell numbers (total, neutrophil, lymphocyte, and eosinophil counts), globulin, amylase, and the BUN/creatinine ratio. Overall, the VC method was associated with the least variation in both sexes and appeared slightly better than the IC method for the parameters evaluated. The largest difference between groups was noted for the transaminase levels. While alanine aminotransferase (ALT) values were similar between the IC and VC groups, aspartate aminotransferase (AST) values were associated with less variation for the VC method. Transaminase levels for the MC and RO groups were associated with relatively large ranges and variation. ALT results from the RO method, the only method amenable to repetitive sample collection used in this evaluation, indicate that this is an acceptable method. The results demonstrate the substantial impact that phlebotomy method has on the assay results and that the VC or IC methods provide the most consistent results. The ranges by collection method and sex provided here can be used to select the preferred method of collection when designing a study and for comparison of data

  15. Effectiveness of a Novel Specimen Collection System in Reducing Blood Culture Contamination Rates.

    Science.gov (United States)

    Bell, Mary; Bogar, Catherine; Plante, Jessica; Rasmussen, Kristen; Winters, Sharon

    2018-04-20

    False-positive blood-culture results due to skin contamination of samples remain a persistent problem for health care providers. Our health system recognized that our rates of contamination across the 4 emergency department campuses were above the national average. A unique specimen collection system was implemented throughout the 4 emergency departments and became the mandatory way to collect adult blood cultures. The microbiology laboratory reported contamination rates weekly to manage potential problems; 7 months of data are presented here. There was an 82.8% reduction in false positives with the unique specimen collection system compared with the standard method (chi-squared test with Yates correction, 2-tailed, P = 0.0001). Based on the historical 3.52% rate of blood-culture contamination for our health facilities, 2.92 false positives were prevented for every 100 blood cultures drawn, resulting from adoption of the unique specimen collection system as the standard of care. This unique collection system can reduce the risk of blood culture contamination significantly and is designed to augment, rather than replace, the standard phlebotomy protocol already in use in most health care settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Serial killer: il database mondiale

    Directory of Open Access Journals (Sweden)

    Gaetano parente

    2016-07-01

    Full Text Available The complex and multisided study of serial killers is partly made difficult by the current level of progress that has led these deviant people to evolve in relation to the aspects of shrewdness (concerning the staging and mobility. Despite the important work of some scholars who proposed important theories, all this shows that, concerning serial murders, it is still particularly frequent not to pay attention to links among homicides committed by the same person but in different parts of the world. It is therefore crucial to develop a worldwide database that allows all police forces to access information collected on crime scenes of murders which are particularly absurd and committed without any apparent reason. It will then be up to the profiler, through ad hoc and technologically advanced tools, to collect this information on the crime scene that would be made available to all police forces thanks to the worldwide database.

  17. Blood meal identification and feeding habits of uranotaenia species collected in the ryukyu archipelago.

    Science.gov (United States)

    Toma, Takako; Miyagi, Ichiro; Tamashiro, Mikako

    2014-09-01

    To know the blood meal in the stomach of Uranotaenia species, blood-fed mosquitoes were collected by 4 methods at different sites in the mountain forest of 3 islands, Amamioshima, Okinawajima, and Iriomotejima in the Ryukyu Archipelago, Japan from 2005 to 2012. One hundred twenty-four blood-fed Uranotaenia mosquitoes of 7 species (Ur. jacksoni, nivipleura, ohamai, yaeyamana, annandalei, lateralis, and macfarlanei) were collected. The collection rates are 0.26, 0.6, 0.31, and 0.66 by black light trap, black light blue with dry ice trap, frog call trap, and sweeping net, respectively. The blood meals of 107 females (86.3%) were successfully identified by a polymerase chain reaction-based method. All Uranotaenia species fed on cold-blooded animals, especially amphibians (99.1%), and notably on frogs. They would feed readily on available frogs in a given region having no close connection with the breeding (calling) season of each frog. They also fed on reptiles (0.9%), but not on warm-blooded animals.

  18. Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    Science.gov (United States)

    Kessler, Harald H.; Stelzl, Evelyn; Raggam, Reinhard B.; Haas, Josef; Kirchmeir, Franz; Hegenbarth, Karin; Daghofer, Elisabeth; Santner, Brigitte I.; Marth, Egon; Stauber, Rudolf E.

    2001-01-01

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport. PMID:11325991

  19. Blood groups and human groups: collecting and calibrating genetic data after World War Two.

    Science.gov (United States)

    Bangham, Jenny

    2014-09-01

    Arthur Mourant's The Distribution of the Human Blood Groups (1954) was an "indispensable" reference book on the "anthropology of blood groups" containing a vast collection of human genetic data. It was based on the results of blood-grouping tests carried out on half-a-million people and drew together studies on diverse populations around the world: from rural communities, to religious exiles, to volunteer transfusion donors. This paper pieces together sequential stages in the production of a small fraction of the blood-group data in Mourant's book, to examine how he and his colleagues made genetic data from people. Using sources from several collecting projects, I follow how blood was encountered, how it was inscribed, and how it was turned into a laboratory resource. I trace Mourant's analytical and representational strategies to make blood groups both credibly 'genetic' and understood as relevant to human ancestry, race and history. In this story, 'populations' were not simply given, but were produced through public health, colonial and post-colonial institutions, and by the labour and expertise of subjects, assistants and mediators. Genetic data were not self-evidently 'biological', but were shaped by existing historical and geographical identities, by political relationships, and by notions of kinship and belonging. Copyright © 2014 The Author. Published by Elsevier Ltd.. All rights reserved.

  20. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  1. CRNL library serials list

    International Nuclear Information System (INIS)

    Alburger, T.P.

    1982-04-01

    A list of 1900 serial publications (periodicals, society transactions and proceedings, annuals and directories, indexes, newspapers, etc.) is presented with volumes and years held by the Main Library. This library is the largest in AECL as well as one of the largest scientific and technical libraries in North America, and functions as a Canadian resource for nuclear information. A main alphabetical list is followed by broad subject field lists representing research interests, and lists of abstract and index serials, general bibliographic serials, conference indexes, press releases, English translations, and original language journals

  2. A Survey of Electronic Serials Managers Reveals Diversity in Practice

    Directory of Open Access Journals (Sweden)

    Laura Costello

    2014-09-01

    Full Text Available A Review of: Branscome, B. A. (2013. Management of electronic serials in academic libraries: The results of an online survey. Serials Review, 39(4, 216-226. http://dx.doi.org/10.1016/j.serrev.2013.10.004 Abstract Objective – To examine industry standards for the management of electronic serials and measure the adoption of electronic serials over print. Design – Survey questionnaire. Setting – Email lists aimed at academic librarians working in serials management. Subjects – 195 self-selected subscribers to serials email lists. Methods – The author created a 20 question survey that consisted primarily of closed-ended questions pertaining to the collection demographics, staff, budget, and tools of serials management groups in academic libraries. The survey was conducted via Survey Monkey and examined using the analytical features of the tool. Participants remained anonymous and the survey questions did not ask them to reveal identifiable information about their libraries. Main Results – Collection demographics questions revealed that 78% of surveyed librarians estimated that print-only collections represented 40% or fewer of their serials holdings. The author observed diversity in the factors that influence print to digital transitions in academic libraries. However 71.5% of participants indicated that publisher technology support like IP authentication was required before adopting digital subscriptions. A lack of standardization also marked serials workflows, department responsibilities, and department titles. The author did not find a correlation between serials budget and the enrollment size of the institution. Participants reported that they used tools from popular serials management vendors like Serials Solutions, Innovative Interfaces, EBSCO, and Ex Libris, but most indicated that they used more than one tool for serials management. Participants specified 52 unique serials management products used in their libraries. Conclusion

  3. Blood collection from the facial (maxillary)/musculo-cutaneous vein in true frogs (family Ranidae).

    Science.gov (United States)

    Forzán, María J; Vanderstichel, Raphaël V; Ogbuah, Christopher T; Barta, John R; Smith, Todd G

    2012-01-01

    Collection of blood from amphibians, as in other classes of vertebrate animals, is essential to evaluate parameters of health, diagnose hemoparasitism, identify viral and bacterial pathogens, and measure antibodies. Various methods of blood collection have been described for amphibians. Most can be cumbersome (venipucture of femoral vein, ventral abdominal vein or lingual venus plexus) or result in pain or deleterious health consequences (cardiac puncture and toe-clipping). We describe an easy and practical technique to collect blood from frogs and toads that can be used in multiple species and is minimally invasive. The technique consists of puncturing either the facial or, less commonly, the musculo-cutaneous vein and collecting the blood with a capillary tube. These veins run dorsal and parallel to the maxillary bone and can be accessed by quick insertion and withdrawal of a needle through the skin between the upper jawline and the rostral or caudal side of the tympanum. The needle should be of 27 or 30 gauge for anurans weighing more or less than 25 g, respectively. Although the technique has been used by some amphibian researchers for years, it is little known by others and has never been fully described in a peer-reviewed publication.

  4. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125 Section 864.9125 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  5. Playing at Serial Acquisitions

    NARCIS (Netherlands)

    J.T.J. Smit (Han); T. Moraitis (Thras)

    2010-01-01

    textabstractBehavioral biases can result in suboptimal acquisition decisions-with the potential for errors exacerbated in consolidating industries, where consolidators design serial acquisition strategies and fight escalating takeover battles for platform companies that may determine their future

  6. Classifying serial killers.

    Science.gov (United States)

    Promish, D I; Lester, D

    1999-11-08

    We attempted to match the appearance and demeanor of 27 serial killers to the postmortem 'signatures' found on their victims' bodies. Our results suggest that a link may exist between postmortem signatures and two complementary appearance-demeanor types.

  7. Serial blood donations for intrauterine transfusions of severe hemolytic disease of the newborn with the use of recombinant erythropoietin in a pregnant woman alloimmunized with anti-Ku.

    Science.gov (United States)

    Lydaki, Evaggelia; Nikoloudi, Irene; Kaminopetros, Petros; Bolonaki, Irene; Sifakis, Stavros; Kikidi, Katerina; Koumantakis, Evgenios; Foundouli, Kaliopi

    2005-11-01

    The management of a pregnant woman with the rare Ko phenotype and anti-Ku is a special challenge, because matched blood is extremely rare and the possibility of severe hemolytic disease of the newborn is high. A 30-year-old woman with rare Ko (Knull) phenotype presented at 18 weeks of gestation with positive indirect agglutination test results. She had anti-Ku due to previous blood transfusion, one pregnancy, and two abortions. During this pregnancy, anti-Ku titers ranged from 1024 to 4096. At the 26th week of gestation ultrasound showed a hydropic fetus and urgent intrauterine exchange transfusion was performed with the maternal red blood cells (RBCs). Recombinant human erythropoietin (rHu-EPO) and intravenous (IV) iron were administered to the mother to ensure an adequate supply of matched RBCs for intrauterine transfusions and possible perinatal hemorrhage. Intrauterine transfusions were repeated every 1 to 3 weeks. By 35 weeks 2 days of gestation, the mother had donated 4 units of blood, and four intrauterine transfusions had been performed. Cesarean section was then decided and a healthy male newborn was born. He was treated with phototherapy but without exchange transfusions. By the 15th day of life rHu-EPO was administrated to the newborn because of anemia. The maternal RBCs completely disappeared from the child's blood by Day 100. As shown in this case, treatment with rHu-EPO and IV Fe has effectively increased the mother's capacity to donate RBCs for autologous use and intrauterine transfusions, with no adverse effects to the mother or the child.

  8. Effect of hypergravity on catecholamine levels in telemetrically collected blood of rats during centrifugation

    Science.gov (United States)

    Kvetnansky, R.; Petrak, J.; Mravec, B.; Tillinger, A.; Jurani, M.; Baranovska, M.; Hapala, I.; Frollo, I.

    2005-08-01

    Hypergravity is known to activate the sympathoadrenal system (SAS). Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI) and partly also norepinephrine (NE). However, the collection of blood was performed after centrifugation finished and therefore plasma NE and EPI levels could have been affected by the process of deceleration. The aim of this study was to evaluate plasma EPI and NE levels in blood collected directly during the centrifugation after reaching different +G, using newly developed remote controlled equipment. Such telemetrically regulated equipment for multiple blood sampling allows us to investigate selective effects of hypergravity during centrifugation. All animals had a polyethylene tubing in the tail artery which was connected to a pre-programmed device for three blood withdrawals (0.6 ml each) into individual syringes, performed at any chosen time intervals. Plasma EPI and NE levels were measured at hypergravity between +1G - +5G. Plasma EPI levels showed a huge, hypergravity dependent increase at the interval of 10-20 min. After the blood collection was completed, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples plasma EPI levels showed a significant reduction compared to the 20 min interval of centrifugation but the EPI levels at 4G-6G were still significantly elevated compared to pre- centrifugation levels. Plasma NE levels showed less pronounced changes (increased after 6G only) with a slower return to control levels.Thus, our data has shown completely different responses of the adrenomedullary (epinephrine) and sympathoneural (norepinephrine) systems to hypergravitation. This data shows that the increased gravitation and not the stressful situations connected with centrifugation is the factor responsible for massive activation of the adrenomedullary system. The mechanism of small activation of the

  9. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  10. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  11. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    Science.gov (United States)

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  12. Serial interprocessor communications system

    International Nuclear Information System (INIS)

    Labiak, W.; Siemens, P.; Bailey, C.

    1980-01-01

    A serial communications system based on the EIA RS232-C standard with modem control lines has been developed. The DLV11-E interface is used for this purpose. All handshaking is done with the modem control lines. This allows totally independent full duplex communication. The message format consists of eight bit data with odd parity and a sixteen bit checksum on the whole message. All communications are fully interrupt driven. A program was written to load a program into a remote LSI-11 using the serial line without bootstrap ROM

  13. Blood Collection from Local Abattoirs for Mass Production of Tsetse Flies to be used in the Sterile Insect Technique

    Energy Technology Data Exchange (ETDEWEB)

    Byamungu, M B; Kiimbisa, B; Matembo, S; Mashenga, G [Tsetse and Trypanosomiasis Research Institute, P.O. Box 1026, Tanga (Tanzania, United Republic of)

    2012-07-15

    The mass production of tsetse flies (Glossina spp.) for the sterile insect technique (SIT) requires a supply of quality blood. For some years already cattle blood has been used as food for laboratory reared flies. The blood is collected from an abattoir using standard procedures. The collection procedures, handling and storage require aseptic conditions to avoid contamination of the blood, which could be fatal to the flies. Fly mortality caused by low quality blood endangers the success of mass rearing. To rear healthy flies with good survival and production the blood should be of good quality - free of contamination and with a packed cell volume (PCV) above 25%. The present work involved the seasonal collection of blood from abattoirs in the United Republic of Tanzania (Tanga, Arusha, Dodoma, Dar-es-salaam). Dodoma was identified as having the best conditions for blood collection. To assess the quality of the blood as a diet for tsetse, blood was screened for the presence of bacteria, and the pathogens were identified. Protocols were developed for blood quality assurance. (author)

  14. SERIAL TELEVISI DEXTER SEBAGAI ANAKRONISME DALAM SASTRA POPULER

    OpenAIRE

    Ida Rochani Adi

    2014-01-01

    In the popular literature context, this study aims to investigate: (1) how the formulation of the characterization of Dexter in the television serial Dexter violates the tradition of literary characterization, and (2) how the formula of moral values is dramatized through Dexter, who is a sociopath, psychopath, serial killer, and person without moral. The research object was the television serial Dexter, which ranks five in popularity in the world. The data were collected by documenting 84 epi...

  15. Selection and Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Chen, Jing

    2013-01-01

    There is substantial evidence that serial entrepreneurs outperform de novo entrepreneurs. But is this positive association between prior experience and performance the result of learning by doing or of selection on ability? This paper proposes a strategy that combines the fixed-effects model and IV...... when the analysis focuses on founding new startups in sectors closely related to entrepreneurs' previous ventures....

  16. Selection and Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Chen, Jing

    2011-01-01

    Although it has been broadly evidenced that entrepreneurial experience plays a substantial role in the emergence of serial entrepreneurship, the debate is still going on about whether this relationship should be attributed to learning by doing or instead be explained by selection on ability. This...

  17. Serial private infrastructures

    NARCIS (Netherlands)

    van den Berg, V.A.C.

    2013-01-01

    This paper investigates private supply of two congestible infrastructures that are serial, where the consumer has to use both in order to consume. Four market structures are analysed: a monopoly and 3 duopolies that differ in how firms interact. It is well known that private supply leads too high

  18. Stress in Harmonic Serialism

    Science.gov (United States)

    Pruitt, Kathryn Ringler

    2012-01-01

    This dissertation proposes a model of word stress in a derivational version of Optimality Theory (OT) called Harmonic Serialism (HS; Prince and Smolensky 1993/2004, McCarthy 2000, 2006, 2010a). In this model, the metrical structure of a word is derived through a series of optimizations in which the "best" metrical foot is chosen…

  19. Suicide in serial killers.

    Science.gov (United States)

    Lester, David; White, John

    2010-02-01

    In a sample of 248 killers of two victims in America from 1900 to 2005, obtained from an encyclopedia of serial killers by Newton (2006), those completing suicide did not differ in sex, race, or the motive for the killing from those who were arrested.

  20. Preserved regional cerebral blood flow in the occipital cortices, brainstem, and cerebellum of patients with V180I-129M genetic Creutzfeldt-Jakob disease in serial SPECT studies.

    Science.gov (United States)

    Hayashi, Yuichi; Yoshikura, Nobuaki; Takekoshi, Akira; Yamada, Megumi; Asano, Takahiko; Kimura, Akio; Satoh, Katsuya; Kitamoto, Tetsuyuki; Inuzuka, Takashi

    2016-11-15

    Creutzfeldt-Jakob disease (CJD) with a causative point mutation of valine to isoleucine at codon 180 (V180I) is one of the major types of genetic CJD (gCJD) in Japan. V180I gCJD is rarely accompanied by a family history, and its clinical characteristics include late-onset, long disease duration, and edematous cortical hyperintensity in diffusion, fluid attenuate inversion and T2-weighted MRI. We performed serial imaging with single-photon emission computed tomography (SPECT) and MRI in three V180I gCJD cases over long-term observation. All cases were characterized by progressive dementia, parkinsonism, and the absence of cerebellar signs or cortical visual dysfunction in their clinical courses. Moreover, during the end-stage, SPECT findings showed preserved regional cerebral blood flow (rCBF) in the occipital cortices, brainstem, and cerebellum. Similarly, no apparent atrophy or increased signal intensities were observed in MRI images of the occipital and cerebellar regions. In conclusion, we report a decrease in rCBF predominantly in the frontal and temporal cortices during the early-stage, which became more widespread as the disease progressed. Importantly, rCBF was preserved in the occipital cortices, brainstem, and cerebellar regions until the end-stage, which may be distinct to V180I gCJD cases. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Successful collection of peripheral blood stem cells upon VIDE chemomobilization in sarcoma patients.

    Science.gov (United States)

    Kriegsmann, Katharina; Heilig, Christoph; Cremer, Martin; Novotny, Philipp; Kriegsmann, Mark; Bruckner, Thomas; Müller-Tidow, Carsten; Egerer, Gerlinde; Wuchter, Patrick

    2017-11-01

    In patients with Ewing sarcoma and some distinct subgroups of soft tissue sarcoma (STS), a quantitatively sufficient autologous peripheral blood stem cell (PBSC) collection for stem cell support might facilitate treatment continuation, dose-intensification, and high-dose chemotherapy. Here, we provide a detailed evaluation of PBSC collection upon vincristine, ifosfamide, doxorubicin, and etoposide (VIDE) chemomobilization. Mobilization and collection parameters of 42 sarcoma patients (Ewing sarcoma n = 35, other STS n = 7) were analyzed retrospectively. Data were evaluated with regard to the number of previous VIDE therapy cycles. All patients reached the collection goal of ≥2.0 × 10 6 CD34 + cells/kg body weight (bw) upon VIDE/G-CSF mobilization, in the majority of cases with one single leukapheresis (LP) session (n = 29, 69%). No significant differences were identified with regard to mobilization and collection variables or the number of previous induction VIDE therapy cycles. However, upon 5 cycles of VIDE, we found the highest relative proportion of patients who required two or three LP sessions. Our data demonstrate the feasibility of successful PBSC collection upon VIDE chemomobilization even after up to five cycles of induction therapy, while at the same time the increasing risk of bone marrow exhaustion with every consecutive cycle is outlined. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Thixotropic gel-like composition and sterile blood-collecting and separating device

    International Nuclear Information System (INIS)

    Semersky, F.E.

    1980-01-01

    A thixotropic gel-like composition comprising liquid polybutadiene and an inorganic inert filler dispersed therein is adapted for use as a sealing barrier between separated phases of differing densities of a fluid in which said composition has at rest a density intermediate said differing densities, said gel-like composition being substantially resistant to sterilizing radiation. There is also disclosed a pre-packaged blood collecting and separating device which contains a mixture of liquid polybutadiene and an inorganic, inert filler, such as silica, as a thixotropic gel adapted at rest to form a sealing barrier between separated blood phases. The device and gel are subjected to sterilizing radiation to form a substantially sterile device, substantially free of backflow contamination without degradation of the physical properties of the gel. (author)

  3. A new voluntary blood collection method for the Andean bear (Tremarctos ornatus) and Asiatic black bear (Ursus thibetanus).

    Science.gov (United States)

    Otaki, Yusuke; Kido, Nobuhide; Omiya, Tomoko; Ono, Kaori; Ueda, Miya; Azumano, Akinori; Tanaka, Sohei

    2015-01-01

    Various training methods have been developed for animal husbandry and health care in zoos and one of these trainings is blood collection. One training method, recently widely used for blood collection in Ursidae, requires setting up a sleeve outside the cage and gives access to limited blood collection sites. A new voluntary blood collection method without a sleeve was applied to the Andean bear (Tremarctos ornatus) and Asiatic black bear (Ursus thibetanus) with access to various veins at the same time. The present study evaluated the effectiveness of this new method and suggests improvements. Two Andean and two Asiatic black bears in Yokohama and Nogeyama Zoological Gardens, respectively, were trained to hold a bamboo pipe outside their cages. We could, thereby, simultaneously access superficial dorsal veins, the dorsal venous network of the hand, the cephalic vein from the carpal joint, and an area approximately 10 cm proximal to the carpal joint. This allowed us to evaluate which vein was most suitable for blood collection. We found that the cephalic vein, approximately 10 cm proximal to the carpal joint, was the most suitable for blood collection. This new method requires little or no modification of zoo facilities and provides a useful alternative method for blood collection. It could be adapted for use in other clinical examinations such as ultrasound examination. © 2015 Wiley Periodicals, Inc.

  4. Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies

    Science.gov (United States)

    Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.

    2014-01-01

    Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728

  5. Serial alterations in digital hemodynamics and endothelin-1 immunoreactivity, platelet-neutrophil aggregation, and concentrations of nitric oxide, insulin, and glucose in blood obtained from horses following carbohydrate overload.

    Science.gov (United States)

    Eades, Susan C; Stokes, Ashley M; Johnson, Philip J; LeBlanc, Casey J; Ganjam, Venkataseshu K; Buff, Preston R; Moore, Rustin M

    2007-01-01

    To quantify changes in endothelium-derived factors and relate those changes to various aspects of digital hemodynamics during the prodromal stages of carbohydrate overload (CHO)-induced laminitis in horses. 20 adult horses without abnormalities of the digit. Digital and jugular venous blood samples were collected at 1-hour intervals (for assessment of endothelin-1 [ET-1] immunoreactivity and measurement of glucose, insulin, and nitric oxide [NO] concentrations) or 4-hour intervals (CBC and platelet-neutrophil aggregate assessment) for 8 hours or 16 hours after induction of CHO-associated laminitis in horses treated with an ET-1 antagonist. Effects of treatment, collection site, and time and the random effects of horse on each variable were analyzed by use of a repeated-measures model. Where treatment and collection site had no significant effect, data were combined. Compared with baseline values, CHO resulted in changes in several variables, including a significant increase from baseline in digital blood ET-like immunoreactivity at 11 hours; digital blood ET-like immunoreactivity was significantly greater than that in jugular venous blood at 8, 9, 11, and 12 hours. Digital and jugular venous blood concentrations of glucose increased from baseline significantly at 3, 4, and 5 hours; insulin concentration increased significantly at 5 hours; and the number of platelet-neutrophil aggregates increased significantly at 12 hours. In horses, concurrent increases in venous blood ET-1 immunoreactivity, insulin and glucose concentrations, and platelet-neutrophil aggregates support a role of endothelial dysfunction in the pathogenesis of CHO-induced laminitis.

  6. Concordance of mutation detection in circulating tumor DNA in early clinical trials using different blood collection protocols

    DEFF Research Database (Denmark)

    Ahlborn, Lise B.; Madsen, Mette; Jonson, Lars

    2017-01-01

    in a clinical setting. Here we investigate the concordance between standard blood collection for molecular analysis using immediate separation of plasma, compared to the use of collection tubes allowing for delayed processing. Methods: In this study, we measured the fractional abundance of tumor specific...... patients with advanced solid cancers enrolled in early clinical trials. Results: Concordance in the fractional abundance of mutations in ctDNA isolated from blood collected in either K3EDTA or BCT tubes from patients with different solid cancers was observed. Conclusions: This study indicates that BCT...... mutations (BRAF p.V600E and PIK3CA p.H1047R) in ctDNA isolated from blood samples collected in either cell-stabilizing Cell-Free DNA BCT tubes (delayed processing within 72 hours) or standard K3EDTA tubes (immediate processing within 15 minutes). Twenty-five blood sample pairs (EDTA/BCT) were collected from...

  7. Analysis of assembly serial number usage in domestic light-water reactors

    International Nuclear Information System (INIS)

    Reich, W.J.; Moore, R.S.

    1991-05-01

    Domestic light-water reactor (LWR) fuel assemblies are identified by a serial number that is placed on each assembly. These serial numbers are used as identifiers throughout the life of the fuel. The uniqueness of assembly serial numbers is important in determining their effectiveness as unambiguous identifiers. The purpose of this study is to determine what serial numbering schemes are used, the effectiveness of these schemes, and to quantify how many duplicate serial numbers occur on domestic LWR fuel assemblies. The serial numbering scheme adopted by the American National Standards Institute (ANSI) ensures uniqueness of assembly serial numbers. The latest numbering scheme adopted by General Electric (GE), was also found to be unique. Analysis of 70,971 fuel assembly serial numbers from permanently discharged fuel identified 11,948 serial number duplicates. Three duplicate serial numbers were found when analysis focused on duplication within the individual fuel inventory at each reactor site, but these were traced back to data entry errors and will be corrected by the Energy Information Administration (EIA). There were also three instances where the serial numbers used to identify assemblies used for hot cell studies differed from the serial numbers reported to the EIA. It is recommended that fuel fabricators and utilities adhere to the ANSI serial numbering scheme to ensure serial number uniqueness. In addition, organizations collecting serial number information, should request that all known serial numbers physically attached or associated with each assembly be reported and identified by the corresponding number scheme. 10 refs., 5 tabs

  8. Evaluating the optimum rest period prior to blood collection for fractionated plasma free metanephrines analysis

    LENUS (Irish Health Repository)

    Griffin, T.P.

    2016-05-01

    The high diagnostic accuracy of plasma metanephrines (PMets) in the di-agnosis of Phaeochromocytoma\\/Paraganglioma (PPGL) is well established. Considerable controversy exists regarding optimum sampling conditions for PMets. The use of reference intervals that do not compromise diagnostic sensitivity is recommended. However, the optimum rest period prior to sampling has yet to be clearly established. The aim of this study was to evaluate PMets concentrations in paired blood samples collected following 30 and 40 min seated-rest prior to sampling, in patients in whom it was clinically rea-sonable to suspect that PPGL may be present.

  9. Colour coding for blood collection tube closures - a call for harmonisation

    DEFF Research Database (Denmark)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell

    2015-01-01

    including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have...... not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce...

  10. Utilization of serial resources in libraries of selected tertiary ...

    African Journals Online (AJOL)

    Information Impact: Journal of Information and Knowledge Management ... security personnel for adequate monitoring of the serial materials, as well as the need for authors and stakeholders in education to donate more serial materials in order to enrich the collections in the library and enhance academic performance.

  11. Malaysian Serials: Issues and Problems.

    Science.gov (United States)

    Bahri, Che Norma

    This paper analyzes the issues and problems while looking at the trends and developments of serials publishing in Malaysia. The first section provides background; topics addressed include the country and people of Malaysia, the history of serials publishing in Malaysia, categories and formats of serials publishing, academic publications,…

  12. External and Internal Citation Analyses Can Provide Insight into Serial/Monograph Ratios when Refining Collection Development Strategies in Selected STEM Disciplines

    Directory of Open Access Journals (Sweden)

    Stephanie Krueger

    2016-12-01

    Full Text Available A Review of: Kelly, M. (2015. Citation patterns of engineering, statistics, and computer science researchers: An internal and external citation analysis across multiple engineering subfields. College and Research Libraries, 76(7, 859-882. http://doi.org/10.5860/crl.76.7.859 Objective – To determine internal and external citation analysis methods and their potential applicability to the refinement of collection development strategies at both the institutional and cross-institutional levels for selected science, technology, engineering, and mathematics (STEM subfields. Design – Multidimensional citation analysis; specifically, analysis of citations from 1 key scholarly journals in selected STEM subfields (external analysis compared to those from 2 local doctoral dissertations in similar subfields (internal analysis. Setting – Medium-sized, STEM-dominant public research university in the United States of America. Subjects – Two citation datasets: 1 14,149 external citations from16 journals (i.e., 2 journals per subfield; citations from 2012 volumes representing bioengineering, civil engineering, computer science (CS, electrical engineering, environmental engineering, operations research, statistics (STAT, and systems engineering; and 2 8,494 internal citations from 99 doctoral dissertations (18-22 per subfield published between 2008-–2012 from CS, electrical and computer engineering (ECE, and applied information technology (AIT and published between 2005-–2012 for systems engineering and operations research (SEOR and STAT. Methods – Citations, including titles and publication dates, were harvested from source materials and stored in Excel and then manually categorized according to format (book, book chapter, journal, conference proceeding, website, and several others. To analyze citations, percentages of occurrence by subfield were calculated for variables including format, age (years since date cited, journal distribution, and the

  13. Delaware's first serial killer.

    Science.gov (United States)

    Inguito, G B; Sekula-Perlman, A; Lynch, M J; Callery, R T

    2000-11-01

    The violent murder of Shirley Ellis on November 29, 1987, marked the beginning of the strange and terrible tale of Steven Bryan Pennell's reign as the state of Delaware's first convicted serial killer. Three more bodies followed the first victim, and all had been brutally beaten and sadistically tortured. The body of a fifth woman has never been found. State and county police collaborated with the FBI to identify and hunt down their suspect, forming a task force of over 100 officers and spending about one million dollars. Through their knowledge and experience with other serial killers, the FBI was able to make an amazingly accurate psychological profile of Delaware's serial killer. After months of around-the-clock surveillance, Steven Pennell was arrested on November 29, 1988, one year to the day after the first victim was found. Pennell was found guilty in the deaths of the first two victims on November 29, 1989, and plead no contest to the murder of two others on October 30, 1991. Still maintaining his innocence, he asked for the death penalty so that he could spare his family further agony. Steven Pennell was executed by lethal injection on March 15, 1992.

  14. Collection and storage of red blood cells with anticoagulant and additive solution with a physiologic pH

    NARCIS (Netherlands)

    Burger, Patrick; Korsten, Herbert; Verhoeven, Arthur J.; de Korte, Dirk; van Bruggen, Robin

    2012-01-01

    BACKGROUND: A donation of whole blood is most commonly collected in acidic citrate-phosphate-dextrose (CPD) variants with pH 5.2 to 6.2 as anticoagulants. Previously, we have shown that the initial pH after red blood cell (RBC) preparation can have an effect on RBCs during storage. First, we

  15. Events at blood collection area due to nonconforming blood bags and plateletpheresis kits: need for timely corrective and preventive actions.

    Science.gov (United States)

    Verma, Anupam; Sachan, Deepti; Elhence, Priti; Pandey, Hem; Dubey, Anju

    2012-07-01

    Good blood banking practice requires that every effort should be made to detect any deviation or defect in blood bank products and to identify any potential risk to blood donor or recipient(s). We report the findings of an exercise that provide an insight into why feedback from the user side is crucial. Various events involving blood bags and plateletpheresis kits and the corresponding appropriate actions instituted for remedial measures were recorded. These scattered events were recorded for 6 months following the use of a new batch of improved blood bags with add-on features. Several events related to plateletpheresis kits from three different manufacturers were also recorded for 1 year. The affected blood bags were utilized with no untoward incident. The complaint was closed following satisfactory response from the blood bag manufacturing company that acted in a timely manner in addressing the root causes of the problems. However, corrective and preventive actions (CAPA) could not be implemented for plateletpheresis kits. The rate of undesirable events was higher with plateletpheresis kits as compared with whole blood bags (1.75% vs. 0.06%). As defects or deviations that trigger the need for CAPA can stem from numerous sources, it is important to clearly identify and document the problems and level of risk so that appropriate investigations can be instituted and remedial actions can be taken in a timely manner. This study demonstrates the usefulness of a quality initiative to collate and analyze blood product faults in conjunction with blood product manufacturers. © 2012 American Association of Blood Banks.

  16. Improving the blood supply chain: simulation and optimisation models to support collection, production and location-allocation decisions

    OpenAIRE

    Osorio Muriel, Andres

    2016-01-01

    This thesis introduces and studies different problems in the blood supply chain. The problems are focused on aspects less frequently studied in the literature such as the exploitation of the different collection and production alternatives, consideration of multiple products and uncertainty in demand and supply. These important features can be found in different decision levels, including daily collections, annual planning and at the strategic level when the blood supply chain is designed. Fo...

  17. Broad ion beam serial section tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winiarski, B., E-mail: b.winiarski@manchester.ac.uk [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Materials Division, National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Gholinia, A. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Mingard, K.; Gee, M. [Materials Division, National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Thompson, G.E.; Withers, P.J. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom)

    2017-01-15

    Here we examine the potential of serial Broad Ion Beam (BIB) Ar{sup +} ion polishing as an advanced serial section tomography (SST) technique for destructive 3D material characterisation for collecting data from volumes with lateral dimensions significantly greater than 100 µm and potentially over millimetre sized areas. Further, the associated low level of damage introduced makes BIB milling very well suited to 3D EBSD acquisition with very high indexing rates. Block face serial sectioning data registration schemes usually assume that the data comprises a series of parallel, planar slices. We quantify the variations in slice thickness and parallelity which can arise when using BIB systems comparing Gatan PECS and Ilion BIB systems for large volume serial sectioning and 3D-EBSD data acquisition. As a test case we obtain 3D morphologies and grain orientations for both phases of a WC-11%wt. Co hardmetal. In our case we have carried out the data acquisition through the manual transfer of the sample between SEM and BIB which is a very slow process (1–2 slice per day), however forthcoming automated procedures will markedly speed up the process. We show that irrespective of the sectioning method raw large area 2D-EBSD maps are affected by distortions and artefacts which affect 3D-EBSD such that quantitative analyses and visualisation can give misleading and erroneous results. Addressing and correcting these issues will offer real benefits when large area (millimetre sized) automated serial section BIBS is developed. - Highlights: • In this work we examine how microstructures can be reconstructed in three-dimensions (3D) by serial argon broad ion beam (BIB) milling, enabling much larger volumes (>250×250×100µm{sup 3}) to be acquired than by serial section focused ion beam-scanning electron microscopy (FIB-SEM). • The associated low level of damage introduced makes BIB milling very well suited to 3D-EBSD acquisition with very high indexing rates. • We explore

  18. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  19. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    Science.gov (United States)

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  20. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    Science.gov (United States)

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged 18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  1. Volume-dependent hemodynamic effects of blood collection in canine donors - evaluation of 13% and 15% of total blood volume depletion

    Directory of Open Access Journals (Sweden)

    RUI R.F. FERREIRA

    2015-03-01

    Full Text Available Background: There is no consensus regarding the blood volume that could be safely donated by dogs, ranging from 11 to 25% of its total blood volume (TBV. No previous studies evaluated sedated donors.Aim: To evaluate the hemodynamic effects of blood collection from sedated and non-sedated dogs and to understand if such effects were volume-dependent.Materials and Methods: Fifty three donations of 13% of TBV and 20 donations of 15% TBV were performed in dogs sedated with diazepam and ketamine. Additionally, a total of 30 collections of 13% TBV and 20 collections of 15% TBV were performed in non-sedated dogs. Non-invasive arterial blood pressures and pulse rates were registered before and 15 min after donation. Results: Post-donation pulse rates increased significantly in both sedated groups, with higher differences in the 15% TBV collections. Systolic arterial pressures decreased significantly in these groups, while diastolic pressures increased significantly in 13% TBV donations. Non-sedated groups revealed a slight, but significant, SBP decrease. No clinical signs related to donations were registered.Conclusion: These results suggest that the collection of 15% TBV in sedated donors induces hemodynamic variations that may compromise the harmlessness of the procedure, while it seems to be a safe procedure in non-sedated dogs.

  2. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  3. Colour coding for blood collection tube closures - a call for harmonisation.

    Science.gov (United States)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Ceriotti, Ferruccio; Theodorsson, Elvar; Panteghini, Mauro

    2015-02-01

    At least one in 10 patients experience adverse events while receiving hospital care. Many of the errors are related to laboratory diagnostics. Efforts to reduce laboratory errors over recent decades have primarily focused on the measurement process while pre- and post-analytical errors including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce the risk of pre-analytical errors and improve the patient safety.

  4. A new strategy for umbilical cord blood collection developed at the first Colombian public cord blood bank increases total nucleated cell content.

    Science.gov (United States)

    Vanegas, Diana; Triviño, Lady; Galindo, Cristian; Franco, Leidy; Salguero, Gustavo; Camacho, Bernardo; Perdomo-Arciniegas, Ana-María

    2017-09-01

    The total nucleated cell dosage of umbilical cord blood (UCB) is an important factor in determining successful allogeneic hematopoietic stem cell transplantation after a minimum human leukocyte antigen donor-recipient match. The northern South American population is in need of a new-generation cord blood bank that cryopreserves only units with high total nucleated cell content, thereby increasing the likelihood of use. Colombia set up a public cord blood bank in 2014; and, as a result of its research for improving high total nucleated cell content, a new strategy for UCB collection was developed. Data from 2933 collected and 759 cryopreserved cord blood units between 2014 and 2015 were analyzed. The correlation of donor and collection variables with cellularity was evaluated. Moreover, blood volume, cell content, CD34+ count, clonogenic capacity, and microbial contamination were assessed comparing the new method, which combines in utero and ex utero techniques, with the conventional strategies. Multivariate analysis confirmed a correlation between neonatal birth weight and cell content. The new collection method increased total nucleated cell content in approximately 26% and did not alter pre-cryopreservation and post-thaw cell recovery, viability, or clonogenic ability. Furthermore, it showed a remarkably low microbial contamination rate (1.2%). The strategy for UCB collection developed at the first Colombian public cord blood bank increases total nucleated cell content and does not affect unit quality. The existence of this bank is a remarkable breakthrough for Latin-American patients in need of this kind of transplantation. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  5. Retrospective evaluation of unexpected events during collection of blood donations performed with and without sedation in cats (2010-2013).

    Science.gov (United States)

    Doolin, Kerry S; Chan, Daniel L; Adamantos, Sophie; Humm, Karen

    2017-09-01

    Describe unexpected events (UEs) that occurred during blood donation in cats with and without sedation. Retrospective observational study (2010-2013). University teaching hospital. Client-owned healthy cats enrolled in a blood donation program. None. Blood collection for transfusion was performed 115 times from 32 cats. Seventy donation events were in unsedated cats and 45 in sedated cats. For each collection, the anticipated blood volume to be collected, actual blood volume collected, sedation protocol, and any UE in the peridonation period were recorded. There were 6 categories of UEs: movement during donation, donor anxiety, inadequate collected blood volume, jugular vessel related UEs, additional sedation requirement, and cardiorespiratory distress. Fisher's exact test was used to compare the frequency of UEs between sedated and unsedated cats. UEs were recorded in 54 of 115 collections. In the donor population, movement was reported as an UE in 0 cats that donated under sedation and 24/70 (34.3%) cats that donated without sedation (P donated under sedation and 14/70 (20.0%) cats that donated unsedated (P = 0.014). Unsedated donation did not increase the likelihood of inadequate donation volume, jugular vessel related UEs, or cardiorespiratory distress. Eight of 45 (17.8%) sedated donations required additional sedation. Movement during donation and signs of donor anxiety were more frequent in unsedated cats. These were considered minor issues, expected in unsedated cats being gently restrained. Blood collection from unsedated feline donors is a viable alternative to sedated donation. © Veterinary Emergency and Critical Care Society 2017.

  6. Levels of persistent fluorinated, chlorinated and brominated compounds in human blood collected in Sweden in 1997-2000

    Energy Technology Data Exchange (ETDEWEB)

    Lindstroem, G.; Kaerrman, A.; Bavel, B. van [MTM Research Centre, Oerebro Univ. (Sweden); Hardell, L. [Dept. of Oncology, Univ. Hospital, Oerebro (Sweden); Hedlund, B. [Environmental Monitoring Section, Swedish EPA, Stockholm (Sweden)

    2004-09-15

    Levels of persistent fluorinated, chlorinated and brominated compounds in blood collected from the Swedish population have been determined in connection with several exposure and monitoring studies at the MTM Research Centre. A data base with 631 individual congener specific measurements on halogenated POPs such as dioxins, PCBs, HCB, DDE, chlordanes, PBDEs and PFAs including information on residency, age, BMI, diet, occupation, number of children, smoking habits, immunological status etc. has been compiled from samples collected between 1994 and 2004. A brief overview focusing on levels of some persistent chlorinated, brominated and fluorinated, compounds in blood collected in a background population group (n=83) in 1997-2000 is given here.

  7. Hypergravity-induced increase in plasma catecholamine and corticosterone levels in telemetrically collected blood of rats during centrifugation.

    Science.gov (United States)

    Petrak, Juraj; Mravec, Boris; Jurani, Marian; Baranovska, Magda; Tillinger, Andrej; Hapala, Ivan; Frollo, Ivan; Kvetnanský, Richard

    2008-12-01

    Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI), norepinephrine (NE), and corticosterone. However, the collection of blood was performed after a centrifugation finished, and therefore the levels could be affected by the process of deceleration. The aim of this study was to evaluate plasma EPI, NE, and corticosterone levels in blood collected directly during centrifugation after reaching different G (2-6), using newly developed remote-controlled equipment. Animals placed into the centrifuge cabins had inserted polyethylene tubing in the tail artery, which was connected with a preprogrammed device for blood withdrawals. Plasma EPI, NE, and corticosterone levels were measured at different time intervals of hypergravity of 2-6G. Plasma EPI levels showed a huge, hypergravity-level-dependent increase. After the last blood collection was completed during hypergravity, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples, plasma EPI showed significantly lower levels compared to centrifugation intervals. Plasma NE levels were significantly increased after 6G only. The increase in plasma corticosterone was dependent on level of G, however after the centrifuge stopped, corticosterone levels remained elevated. Thus, our data show that hypergravity highly activates the adrenomedullary and hypothalamo-pituitary-adrenocortical systems, whereas the sympathoneural system is activated only at high hypergravity. Immediately after centrifugation is over, EPI levels quickly return to control values. Our technique of blood collection during centrifugation allows assessment of the real hormonal levels at the particular hypergravity value.

  8. Peripheral blood CD34+ cell count as a predictor of adequacy of hematopoietic stem cell collection for autologous transplantation

    Directory of Open Access Journals (Sweden)

    Combariza, Juan F.

    2016-10-01

    Full Text Available Introduction: In order to carry out an autologous transplantation, hematopoietic stem cells should be mobilized to peripheral blood and later collected by apheresis. The CD34+ cell count is a tool to establish the optimal time to begin the apheresis procedure. Objective: To evaluate the association between peripheral blood CD34+ cell count and the successful collection of hematopoietic stem cells. Materials and methods: A predictive test evaluation study was carried out to establish the usefulness of peripheral blood CD34+ cell count as a predictor of successful stem cell collection in patients that will receive an autologous transplantation. Results: 77 patients were included (median age: 49 years; range: 5-66. The predominant baseline diagnosis was lymphoma (53.2 %. The percentage of patients with successful harvest of hematopoietic stem cells was proportional to the number of CD34+cells in peripheral blood at the end of the mobilization procedure. We propose that more than 15 CD34+cells/μL must be present in order to achieve an adequate collection of hematopoietic stem cells. Conclusion: Peripheral blood CD34+ cell count is a useful tool to predict the successful collection of hematopoietic stem cells.

  9. SERIAL TELEVISI DEXTER SEBAGAI ANAKRONISME DALAM SASTRA POPULER

    Directory of Open Access Journals (Sweden)

    Ida Rochani Adi

    2014-06-01

    Full Text Available In the popular literature context, this study aims to investigate: (1 how the formulation of the characterization of Dexter in the television serial Dexter violates the tradition of literary characterization, and (2 how the formula of moral values is dramatized through Dexter, who is a sociopath, psychopath, serial killer, and person without moral. The research object was the television serial Dexter, which ranks five in popularity in the world. The data were collected by documenting 84 episodes of the serial having been broadcast since 2006. They were analyzed by means of content analysis and qualitative descriptive techniques. Based on the findings, the conclusions are as follows. First, there is a violation or anachronism of characterization through the main character in the serial. Second, the dramatized moral values still contain conventional values although they are in different forms.

  10. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  11. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts.

    Science.gov (United States)

    Mrazek, Cornelia; Simundic, Ana-Maria; Wiedemann, Helmut; Krahmer, Florian; Felder, Thomas Klaus; Kipman, Ulrike; Hoppe, Uta; Haschke-Becher, Elisabeth; Cadamuro, Janne

    2017-07-26

    Blood collection through intravenous (IV) catheters is a common practice at emergency departments (EDs). This technique is associated with higher in vitro hemolysis rates and may even be amplified by the use of vacuum collection tubes. Our aim was to investigate the association of five different vacuum tubes with hemolysis rates in comparison to an aspiration system under real-life conditions and to propose an equation to estimate the amount of hemolysis, depending on the vacuum collection tube type. We retrospectively evaluated hemolysis data of plasma samples from our ED, where blood is drawn through IV catheters. Over the past 5 years, we compared 19,001 hemolysis index values amongst each other and against the respective vacuum pressure (Pv) of the collection tubes, which were used within the six observational periods. The highest hemolysis rates were associated with full-draw evacuated tubes. Significantly reduced hemolysis was observed for two kinds of partial-draw tubes. The hemolysis rate of one partial-draw blood collection tube was comparable to those of the aspiration system. Regression analysis of Pv and mean free hemoglobin (fHb) values yielded the formula fHb (g/L)=0.0082*Pv2-0.1143*Pv+ 0.5314 with an R2 of 0.99. If IV catheters are used for blood collection, hemolysis rates directly correlate with the vacuum within the tubes and can be estimated by the proposed formula. By the use of partial-draw vacuum blood collection tubes, hemolysis rates in IV catheter collections can be reduced to levels comparable with collections performed by aspiration systems.

  12. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  13. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  14. Knowledge and attitudes of pregnant women with regard to collection, testing and banking of cord blood stem cells.

    Science.gov (United States)

    Fernandez, Conrad V; Gordon, Kevin; Van den Hof, Michiel; Taweel, Shaureen; Baylis, Françoise

    2003-03-18

    Umbilical cord blood is used as a source of hematopoietic stem cells for bone marrow transplantation in the treatment of malignant and nonmalignant disease. We sought to examine pregnant women's knowledge and attitudes regarding cord blood banking, as their support is crucial to the success of cord blood transplant programs. A questionnaire examining sociodemographic factors and women's attitudes to cord blood banking was developed on the basis of findings from 2 focus groups and a pilot study. The questionnaire was distributed to 650 women attending antenatal clinics at a regional women's hospital between April and July 2001. A total of 443 women (68%) responded. More than half of the women (307/438 or 70% [95% confidence interval, CI, 66% to 74%]) reported poor or very poor knowledge about cord blood banking. Many of the respondents (299/441 or 68% [95% CI 63% to 72%]) thought that physicians should talk to pregnant women about the collection of cord blood, and they wanted to receive information about this topic from health care professionals (290/441 or 66% [95% CI 61% to 70%]) or prenatal classes (308/441 or 70% [95% CI 65% to 74%]). Most of the women (379/442 or 86% [95% CI 82% to 89%]) would elect to store cord blood in a public bank, many citing altruism as the reason for this choice. A much smaller proportion (63/442 or 14% [95% CI 11% to 18%]) would elect private banking, indicating that this would be a good investment or that they would feel guilty if the blood had not been stored. Additional acceptable uses for cord blood included research (mentioned by 294/436 women or 67% [95% CI 63% to 72%]) and gene therapy (mentioned by 169/437 women or 39% [95% CI 34% to 43%]). Most of the women in this study supported the donation of cord blood to public cord blood banks for potential transplantation and research.

  15. Serial Network Flow Monitor

    Science.gov (United States)

    Robinson, Julie A.; Tate-Brown, Judy M.

    2009-01-01

    Using a commercial software CD and minimal up-mass, SNFM monitors the Payload local area network (LAN) to analyze and troubleshoot LAN data traffic. Validating LAN traffic models may allow for faster and more reliable computer networks to sustain systems and science on future space missions. Research Summary: This experiment studies the function of the computer network onboard the ISS. On-orbit packet statistics are captured and used to validate ground based medium rate data link models and enhance the way that the local area network (LAN) is monitored. This information will allow monitoring and improvement in the data transfer capabilities of on-orbit computer networks. The Serial Network Flow Monitor (SNFM) experiment attempts to characterize the network equivalent of traffic jams on board ISS. The SNFM team is able to specifically target historical problem areas including the SAMS (Space Acceleration Measurement System) communication issues, data transmissions from the ISS to the ground teams, and multiple users on the network at the same time. By looking at how various users interact with each other on the network, conflicts can be identified and work can begin on solutions. SNFM is comprised of a commercial off the shelf software package that monitors packet traffic through the payload Ethernet LANs (local area networks) on board ISS.

  16. Anti-phenolic glycolipid-I (PGL-I determination using blood collection on filter paper in leprosy patients

    Directory of Open Access Journals (Sweden)

    TOMIMORI-YAMASHITA Jane

    1999-01-01

    Full Text Available The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS containing 0.5% gelatin. The classical method for native PGL-I was performed for these eluates, and compared with the antibody determination for sera. It was observed that there is a straight correlation comparing these two methods; although the titles found for the eluates were lower than those obtained for serology. This blood collection method could be useful for investigation of new leprosy cases in field, specially in contacts individuals.

  17. PREDICTIVE VALUE OF CD34+ CELLS IN BLOOD OF PATIENT/DONOR BEFORE HEMATOPOIETIC STEM CELLS COLLECTION BY LEUKAPHERESIS

    Directory of Open Access Journals (Sweden)

    Dragoslav Domanovič

    2004-12-01

    Full Text Available Background. In the study we tried to define a predictive value of the circulating CD34+ cells in patients/ donors blood for estimation of the hematopoietic stem cells (HSC collection efficacy determine the optimal time to initiate the collection by leukapheresis procedure.Methods. We retrospectively analyzed 75 collections of HSC using the Amicus cell separator in 39 patients and 15 donors. Circulating CD34+cell counts in patients/donors were compared to the achieved CD34+ cell yields to determine its predictive value for the collection of a targeted yield of > 2 × 106 CD34+ cells/kg body weight of patient.Results. The results of cell counts confirmed that mobilization regimens were successful and HSC collections efficient. High correlation coefficient (r = 0.82 between the number of circulating CD34+ cells before collection and CD34+ cell yield/kg of patient’s body weight was statistically significant (p < 0.05. With ROC analysis we determined the cut-off value 42 × 106/l CD34+ cell counts in the blood of patients/donors before collection that had a positive predictive value 87% and a negative predictive value 91.6%.Conclusions. Analysis showed that the number of circulating CD34+ cells before the procedure express a very high predictive value and can be used for determining the optimal time to initiate collection of HSC by leukapheresis.

  18. The impact of preapheresis white blood cell count on autologous peripheral blood stem cell collection efficiency and HSC infusion side effect rate.

    Science.gov (United States)

    Sakashita, Araci M; Kondo, Andrea T; Yokoyama, Ana Paula H; Lira, Sanny M C; Bub, Carolina B; Souza, Aline M; Cipolletta, Andrea N F; Alvarez, Kelen C; Hamerschlak, Nelson; Kutner, Jose M; Chiattone, Carlos S

    2018-01-19

    Autologous peripheral blood hematopoietic stem cell (PBSC) collection efficiency (CE) is reportedly affected by the patient's blood properties; however, studies to identify factors correlated with CE have shown inconsistent results. Additionally, variables such as stem cell graft granulocyte content and patient age, sex, and underlying disease, may be associated with hematopietic stem cell (HSC) infusion-related adverse reactions. In this study, we evaluated the correlation of preleukapheresis PB granulocyte count and PBSC harvest variables with CD34 + collection yield and efficiency, and thawed HSC infusion side effect occurrence. We evaluated data from 361 patients who had undergone autologous PBSC transplant. Large volume leukapheresis was the method for PBSC collection. Complete Blood Count and CD34 + cell enumeration were performed in the preapheresis PB and the apheresis product sample. The PBSC grafts were submitted to non-controlled rate freezing after addition of 5% DMSO plus 6% hidroxyethylstarch as a cryoprotectant solution. The cryopreserved graft was thawed in a 37°C water bath and then infused without further manipulation. The CD34 + yield was associated with preapheresis PB CD34 + count and immature granulocyte count. The PBSC CE was negatively correlated with preapheresis white blood cell (WBC), immature granulocyte and granulocyte count. The leukapheresis product total nucleated cell (TNC) and granulocyte content was correlated with the thawed graft infusion side effect occurrence. This study has shown that preapheresis PB WBC and granulocyte counts were associated with leukapheresis CE. Additionally, the leukapheresis product TNC and granulocyte content was correlated with thawed graft infusion side effect occurrence. © 2018 Wiley Periodicals, Inc.

  19. Impact of donor- and collection-related variables on product quality in ex utero cord blood banking.

    Science.gov (United States)

    Askari, Sabeen; Miller, John; Chrysler, Gayl; McCullough, Jeffrey

    2005-02-01

    Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 x 10(7), and 5.2 x 10(6), respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks' gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.

  20. Identification of host blood from engorged mosquitoes collected in western Uganda using cytochrome oxidase I gene sequences.

    Science.gov (United States)

    Crabtree, Mary B; Kading, Rebekah C; Mutebi, John-Paul; Lutwama, Julius J; Miller, Barry R

    2013-07-01

    Emerging infectious disease events are frequently caused by arthropod-borne viruses (arboviruses) that are maintained in a zoonotic cycle between arthropod vectors and vertebrate wildlife species, with spillover to humans in areas where human and wildlife populations interface. The greater Congo basin region, including Uganda, has historically been a hot spot for emergence of known and novel arboviruses. Surveillance of arthropod vectors is a critical activity in monitoring and predicting outbreaks of arboviral disease, and identification of blood meals in engorged arthropods collected during surveillance efforts provides insight into the ecology of arboviruses and their vectors. As part of an ongoing arbovirus surveillance project we analyzed blood meals from engorged mosquitoes collected at five sites in western Uganda November 2008-June 2010. We extracted DNA from the dissected and triturated abdomens of engorged mosquito specimens. Mitochondrial cytochrome c oxidase I gene sequence was amplified by PCR and sequenced to identify the source of the mosquito host blood. Blood meals were analyzed from 533 engorged mosquito specimens; 440 of these blood meals were successfully identified from 33 mosquito species. Species identifications were made for 285 of the 440 identified specimens with the remainder identified to genus, family, or order. When combined with published arbovirus isolation and serologic survey data, our results suggest possible vector-reservoir relationships for several arboviruses, including Rift Valley fever virus and West Nile virus.

  1. Blood donor show behaviour after an invitation to donate : The influence of collection site factors

    NARCIS (Netherlands)

    Merz, E.-M.; Zijlstra, B.J.H.; de Kort, W.L.A.M.

    2017-01-01

    Background and Objectives Show behaviour after invitation to donate varies considerably across donors. More insight into this variation is important for blood banks in achieving stable stocks. This study examined individual factors determining intended show behaviour. Most importantly, however, this

  2. Blood donor show behavior after an invitation to donate: The influence of collection site factors

    NARCIS (Netherlands)

    Merz, E.M.; Zijlstra, Bonne; De Kort, Wim L.A.M.

    2017-01-01

    Background and Objectives Show behaviour after invitation to donate varies considerably across donors. More insight into this variation is important for blood banks in achieving stable stocks. This study examined individual factors determining intended show behaviour. Most importantly, however, this

  3. Opportunity recognition: delineating the process and motivators for serial entrepreneurs

    Directory of Open Access Journals (Sweden)

    Boris Urban

    2011-04-01

    Full Text Available Opportunity recognition is a fundamental research issue in entrepreneurship which this paper empirically investigates for serial entrepreneurs. Initially key definitions and boundary conditions of opportunity recognition are explored to elucidate the relevant motivators driving serial entrepreneurs. After operationalising the various concepts, data is collected by surveying serial entrepreneurs (n= 77 based on pre-determined selection criteria. Since the study’s objective is to build solid theory on these new phenomena, descriptive analysis on the empirical results is provided. To test the hypotheses inferential statistics employing parametric and non-parametric tests are used. The findings reveal that the opportunity recognition behaviours are manifest among serial entrepreneurs, with few significant differences on how many new, major businesses have been pursued, or whether they can be said to be successes.

  4. Time, trust, and transparency: Lessons learned from collecting blood biospecimens for cancer research from the Asian American community.

    Science.gov (United States)

    Dang, Julie H T; Chen, Moon S

    2018-04-01

    Biospecimens from racially diverse groups are needed to advance cancer research. The Asian American Cancer Education Study was developed to increase the number and proportion of blood biospecimen donations from Asian Americans for cancer research. The authors' targeted approach included 2 types of community engagement, in-reach (within institution to Asian American patients with cancer) and outreach (external to institution to the general Asian American community). Participants received in-language biospecimen education followed by the opportunity to donate blood biospecimens. Outreach participants donated through our community biospecimen blood drives, and in-reach participants consented to donating an extra tube of blood during their routine blood draws as a patient. Donated blood biospecimens were spun down to serum and plasma to be stored in a biorepository or were sent to the laboratory to test for cancer-related risk factors. Three hundred eighty-eight Asian Americans donated 1127 blood biospecimens for cancer research. Four hundred twenty tubes of plasma and serum are currently being stored at the cancer center's biorepository, 39 tubes have been used for cancer genomic research, and 668 tubes were used to characterize cancer-related risk factors. Building upon the past decade of the National Cancer Institute-funded Asian American Network for Cancer Awareness, Research, and Training's foundation of trust and service among Asian Americans, researchers were able to leverage relationships not only to introduce the idea of biospecimen contribution to the community but to also exceed expectations with regard to the quantity of blood biospecimens collected from Asian Americans. Cancer 2018;124:1614-21. © 2018 American Cancer Society. © 2018 American Cancer Society.

  5. Blood

    Science.gov (United States)

    ... a reduced production of red blood cells, including: Iron deficiency anemia. Iron deficiency anemia is the most common type of anemia and ... inflammatory bowel disease are especially likely to have iron deficiency anemia. Anemia due to chronic disease. People with chronic ...

  6. Union Listing via OCLC's Serials Control Subsystem.

    Science.gov (United States)

    O'Malley, Terrence J.

    1984-01-01

    Describes library use of Conversion of Serials Project's (CONSER) online national machine-readable database for serials to create online union lists of serials via OCLC's Serial Control Subsystem. Problems in selection of appropriate, accurate, and authenticated records and prospects for the future are discussed. Twenty sources and sample records…

  7. Factors affecting autologous peripheral blood hematopoietic stem cell collections by large-volume leukapheresis: a single center experience

    Directory of Open Access Journals (Sweden)

    Araci Massami Sakashita

    2011-06-01

    Full Text Available Objective: To evaluate factors affecting peripheral bloodhematopoietic stem cell yield in patients undergoing large-volumeleukapheresis for autologous peripheral blood stem cell collection.Methods: Data from 304 consecutive autologous peripheral bloodstem cell donors mobilized with hematopoietic growth factor (usually G-CSF, associated or not with chemotherapy, at Hospital Israelita Albert Einstein between February 1999 and June 2010 were retrospectively analyzed. The objective was to obtain at least 2 x 106CD34+ cells/kg of body weight. Pre-mobilization factors analyzedincluded patient’s age, gender and diagnosis. Post mobilizationparameters evaluated were pre-apheresis peripheral white bloodcell count, immature circulating cell count, mononuclear cell count,peripheral blood CD34+ cell count, platelet count, and hemoglobinlevel. The effect of pre and post-mobilization factors on hematopoietic stem cell collection yield was investigated using logistic regression analysis (univariate and multivariate approaches. Results: Premobilization factors correlating to poor CD34+ cell yield in univariate analysis were acute myeloid leukemia (p = 0.017 and other hematological diseases (p = 0.023. Significant post-mobilization factors included peripheral blood immature circulating cells (p = 0.001, granulocytes (p = 0.002, hemoglobin level (p = 0.016, and CD34+ cell concentration (p < 0.001 in the first harvesting day. However, according to multivariate analysis, peripheral blood CD34+ cell content (p < 0.001 was the only independent factor that significantly correlated to poor hematopoietic stem cell yield. Conclusion: In this study, peripheral blood CD34+ cell concentration was the only factor significantly correlated to yield in patients submitted to for autologous collection.

  8. Molecular DNA identification of blood sources fed on, for Culicine mosquitoes (Diptera: Culicidae collected in the Songkhla province, southern Thailand

    Directory of Open Access Journals (Sweden)

    Theerakamol Pengsakul

    2017-12-01

    Full Text Available Culicine mosquitoes are medically important vectors. Therefore, mosquito control measures are a crucial strategy to interrupt disease transmission. Collection of data on mosquito feeding patterns is crucial for developing an effective vector control strategy. The objective of this study was to use molecular biology methods to identify the sources of DNA in mosquito blood meals. The DNA from blood meals in the mosquito stomachs was extracted and amplified with multiplex PCR, using specific primer sets based on the mitochondrial cytochrome b gene, to identify the DNA sources among human, pig, goat, dog, cow, and chicken. Among the 297 mosquito samples collected in the Songkhla province of Thailand, in Aedes spp. mosquitoes the percentages positive for human, dog, pig, chicken, cow, a mixture of 2 vertebrate DNAs, or of 3, and negative (no identified DNA were 61.90, 2.38, 2.38, 0.60, 0.60, 4.18, 1.20 and 26.79% respectively. In Culex spp. blood meals the rank order was different: fractions positive for chicken, human, dog, cow, goat, pig, a mixture of 2 or 3 vertebrate DNAs, and negative were 40.83, 10.00, 5.00, 4.17, 1.67, 0.83, 8.32, 3.32 and 25.83% respectively. This study shows that feeding behaviors of the two species differ, with most Aedes spp. blood meals containing human blood, while Culex spp. had primarily consumed chicken blood. An improved understanding of the feeding behaviors of mosquitoes could contribute to new, more effective strategies for the control of mosquito populations.

  9. Adjustment of Cell-Type Composition Minimizes Systematic Bias in Blood DNA Methylation Profiles Derived by DNA Collection Protocols.

    Science.gov (United States)

    Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi

    2016-01-01

    Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.

  10. Effects of Clove Oil as a Euthanasia Agent on Blood Collection Efficiency and Serum Cortisol Levels in Danio rerio

    OpenAIRE

    Davis, Daniel J; Klug, Jenna; Hankins, Miriam; Doerr, Holly M; Monticelli, Stephanie R; Song, Ava; Gillespie, Catherine H; Bryda, Elizabeth C

    2015-01-01

    Zebrafish are an important laboratory animal model for biomedical research and are increasingly being used for behavioral neuroscience. Tricaine methanesulfonate (MS222) is the standard agent used for euthanasia of zebrafish. However, recent studies of zebrafish behavior suggest that MS222 may be aversive, and clove oil might be a possible alternative. In this study, we compared the effects of MS222 or clove oil as a euthanasia agent in zebrafish on the volume of blood collected and on serum ...

  11. Adjustment of Cell-Type Composition Minimizes Systematic Bias in Blood DNA Methylation Profiles Derived by DNA Collection Protocols.

    Directory of Open Access Journals (Sweden)

    Yuh Shiwa

    Full Text Available Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03 when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50 when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14 by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45 and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17. These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.

  12. Computer Simulation Study of Collective Phenomena in Dense Suspensions of Red Blood Cells under Shear

    CERN Document Server

    Krüger, Timm

    2012-01-01

    The rheology of dense red blood cell suspensions is investigated via computer simulations based on the lattice Boltzmann, the immersed boundary, and the finite element methods. The red blood cells are treated as extended and deformable particles immersed in the ambient fluid. In the first part of the work, the numerical model and strategies for stress evaluation are discussed. In the second part, the behavior of the suspensions in simple shear flow is studied for different volume fractions, particle deformabilities, and shear rates. Shear thinning behavior is recovered. The existence of a shear-induced transition from a tumbling to a tank-treading motion is demonstrated. The transition can be parameterized by a single quantity, namely the effective capillary number. It is the ratio of the suspension stress and the characteristic particle membrane stress. At the transition point, a strong increase in the orientational order of the red blood cells and a significant decrease of the particle diffusivity are obser...

  13. Increased preoperative collection of autologous blood with recombinant human erythropoietin therapy in tertiary care hospitals of Jammu

    Directory of Open Access Journals (Sweden)

    Kumkum Sharma

    2013-01-01

    Full Text Available Introduction: To study whether the administration of recombinant human erythropoietin increases the amount of autologous blood that can be collected before orthopaedic surgery. Materials and Methods: We conducted a randomized controlled trial of recombinant human erythropoietin in 68 adults scheduled for elective orthopedic procedures. The patients received either erythropoietin 600 units/kg of body weight or placebo intravenously every 5 th day prior to each phlebotomy for 21 days during which time up to 5 units of blood was collected. Patients were excluded from donation when their hematocrit values were less than 33%. All patients received iron sulphate 325mg orally 3 times daily. The mean number of units collected per patient was 4.33 ± 0.4 for erythropoietin group and 3.05± 0.71 for the placebo group. Results: The mean packed red cell volume donated by patients who received erythropoietin was 32% greater than that donated by patients who received placebo (196.3 vs. 169.4 ml, p<0.05. 68% in the placebo group and 9% of patients treated with erythropoietin were unable to donate ≥4 units. No adverse effects were attributed to erythropoietin. While participating in the study, complications developed in 2 patients one in each group necessitating their removal from the study. Conclusion: We conclude that recombinant human erythropoietin increases the ability of the patients about to undergo elective surgery to donate autologous blood units.

  14. Serial MRI studies using gadolinium DTPA in active multiple sclerosis

    International Nuclear Information System (INIS)

    Miller, D.H.; Johnson, G.; Barnes, D.; Rudge, P.; McDonald, W.I.

    1988-01-01

    It has been suggested that blood brain barrier (BBB) impairment is a necessary early event in the pathogenesis of the multiple sclerosis (MS) lesions. To evaluate such an hypothesis in vivo would require: (1) serial imaging studies using a modality with high sensitivity for detecting plaques; (2) a contrast enhancing agent which demonstrates BBB impairment. A serial magnetic resonance imaging (MRI) study was undertaken of a group of MS patients using the contrast agent gadolinium-DTPA. As it has been suggested that T 1 and T 2 relaxation times are longer in acute than chronic MS lesions, these were also measured. 3 refs.; 1 figure

  15. Quantitative assessment of postoperative blood collection in brain tumor surgery under valproate medication.

    Science.gov (United States)

    Psaras, T; Will, B E; Schoeber, W; Rona, S; Mittelbronn, M; Honegger, J B

    2008-11-01

    The aim of the study was to evaluate whether valproate (VPA) increases the risk of bleeding complications in patients undergoing brain tumor surgery. A retrospective chart review of 85 patients operated on between January and December 2005 was performed. 19 patients received VPA, 22 patients were given other anti-epileptic drugs (AEDs), 44 patients received no AEDs. Data analyzed included intraoperative blood loss, transfusion, important comorbidity factors and concomitant diseases. Preoperative and postoperative laboratory data included hemoglobin, hematocrit, fibrinogen, platelet count, INR, prothrombin time, partial thromboplastin time and RBC count. The tumor volume was evaluated by preoperative MRI and CT scans of the brain. All 85 patients underwent a native CT scan of the brain on the first day after the operation. The volume of the resection cavity and the volume of blood were documented. We could show that the volume of the tumor had a significant effect on the amount of blood in the tumor cavity, whereas VPA medication had no effect. In our dataset, we found that tumor size had a significant effect on postoperative blood volume. In contrast, no serious bleeding complications occurred in the patients receiving VPA. Therefore, the present study does not provide any evidence for the need to discontinue VPA medication prior to and during surgery.

  16. Serial murder: An unusual stereotype.

    Science.gov (United States)

    Sane, Mandar R; Mugadlimath, Anand B; Farooqui, Jamebaseer M; Janagond, Anand B; Mishra, Pradeep K

    2017-12-01

    Serial murders attract attention from the media, mental health experts, academia, and the general public. We present a case of serial murders that took place in a limited area and which caused public anxiety and anguish in central India. All the victims were homeless beggars, who were bludgeoned to death (crush injury). Individual murders were initially investigated by different police stations; fortunately, since they sent all the bodies to a common autopsy centre, a forensic pathologist was able to link all the cases, the first person to do so. This emphasises the need for sharing information among police stations and autopsy centres.

  17. Identification of hybrids of painted and milky storks using FTA card-collected blood, molecular markers, and morphologies.

    Science.gov (United States)

    Yee, Elsie Yoke Sim; Zainuddin, Zainal Zahari; Ismail, Ahmad; Yap, Chee Kong; Tan, Soon Guan

    2013-10-01

    Suspicious hybrids of painted storks and milky storks were found in a Malaysian zoo. Blood of these birds was sampled on FTA cards for DNA fingerprinting. Of 44 optimized primers, 6 produced diagnostic markers that could identify hybrids. The markers were based on simple, direct PCR-generated multilocus banding patterns that provided two sets of genetic data, one for each of the two stork species and another for the hybrids. It also revealed that large DNA fragments (3,000 bp) could be amplified from blood collected on FTA cards. When the results of each individual bird's DNA fingerprint were compared with plumage characters, the hybrids were found to express a range of intermediate phenotypic traits of the pure breeds with no dominant plumage characteristic from either parental species.

  18. Effects of Clove Oil as a Euthanasia Agent on Blood Collection Efficiency and Serum Cortisol Levels in Danio rerio.

    Science.gov (United States)

    Davis, Daniel J; Klug, Jenna; Hankins, Miriam; Doerr, Holly M; Monticelli, Stephanie R; Song, Ava; Gillespie, Catherine H; Bryda, Elizabeth C

    2015-09-01

    Zebrafish are an important laboratory animal model for biomedical research and are increasingly being used for behavioral neuroscience. Tricaine methanesulfonate (MS222) is the standard agent used for euthanasia of zebrafish. However, recent studies of zebrafish behavior suggest that MS222 may be aversive, and clove oil might be a possible alternative. In this study, we compared the effects of MS222 or clove oil as a euthanasia agent in zebrafish on the volume of blood collected and on serum levels of cortisol. Greater amounts of serum could be collected and lower serum levels of cortisol were present in fish euthanized with clove oil compared with equipotent dose of MS222. Euthanasia with clove oil did not blunt the expected elevation of serum cortisol levels elicited by an acute premortem stress. According to our findings, clove oil is a fast-acting agent that minimizes the cortisol response to euthanasia in zebrafish and allows the collection of large volumes of blood postmortem. These results represent a significant refinement in euthanasia methods for zebrafish.

  19. Effect of age and blood collection site on the metabolic profile of ...

    African Journals Online (AJOL)

    Different collection site did not affect the examined parameters, but some statistically significant differences were observed between the age groups. However, all the parameters agreed with the data reported in the literature and contribute to our knowledge of the metabolic profile of ostriches. South African Journal of Animal ...

  20. Blood meal analysis and virus detection in blood-fed mosquitoes collected during the 2006-2007 Rift Valley fever outbreak in Kenya.

    Science.gov (United States)

    Lutomiah, Joel; Omondi, David; Masiga, Daniel; Mutai, Collins; Mireji, Paul O; Ongus, Juliette; Linthicum, Ken J; Sang, Rosemary

    2014-09-01

    Rift Valley fever (RVF) is a zoonosis of domestic ruminants in Africa. Blood-fed mosquitoes collected during the 2006-2007 RVF outbreak in Kenya were analyzed to determine the virus infection status and animal source of the blood meals. Blood meals from individual mosquito abdomens were screened for viruses using Vero cells and RT-PCR. DNA was also extracted and the cytochrome c oxidase 1 (CO1) and cytochrome b (cytb) genes amplified by PCR. Purified amplicons were sequenced and queried in GenBank and Barcode of Life Database (BOLD) to identify the putative blood meal sources. The predominant species in Garissa were Aedes ochraceus, (n=561, 76%) and Ae. mcintoshi, (n=176, 24%), and Mansonia uniformis, (n=24, 72.7%) in Baringo. Ae. ochraceus fed on goats (37.6%), cattle (16.4%), donkeys (10.7%), sheep (5.9%), and humans (5.3%). Ae. mcintoshi fed on the same animals in almost equal proportions. RVFV was isolated from Ae. ochraceus that had fed on sheep (4), goats (3), human (1), cattle (1), and unidentified host (1), with infection and dissemination rates of 1.8% (10/561) and 50% (5/10), respectively, and 0.56% (1/176) and 100% (1/1) in Ae. mcintoshi. In Baringo, Ma. uniformis fed on sheep (38%), frogs (13%), duikers (8%), cattle (4%), goats (4%), and unidentified hosts (29%), with infection and dissemination rates of 25% (6/24) and 83.3% (5/6), respectively. Ndumu virus (NDUV) was also isolated from Ae. ochraceus with infection and dissemination rates of 2.3% (13/561) and 76.9% (10/13), and Ae. mcintoshi, 2.8% (5/176) and 80% (4/5), respectively. Ten of the infected Ae. ochraceus had fed on goats, sheep (1), and unidentified hosts (2), and Ae. mcintoshi on goats (3), camel (1), and donkey (1). This study has demonstrated that RVFV and NDUV were concurrently circulating during the outbreak, and sheep and goats were the main amplifiers of these viruses respectively.

  1. The Rise in Consumerism: The Year's Work in Serials, 1990.

    Science.gov (United States)

    Lonberger, Jana

    1991-01-01

    Examines major issues and trends in serials management represented in the literature published during 1990. Topics covered include the pricing crisis; publishing and scholarly communication; cancellation projects; technological developments and alternatives to print; claiming and replacement activities; acquisitions and collection development;…

  2. Peripheral blood stem cell collection for allogeneic hematopoietic stem cell transplantation: Practical implications after 200 consequent transplants.

    Science.gov (United States)

    Goren Sahin, Deniz; Arat, Mutlu

    2017-12-01

    Proper stem cell mobilization is one of the most important steps in hematopoietic stem cell transplantation (HSCT). The aim of this paper is to share our 6 years' experience and provide practical clinical approaches particularly for stem cell mobilization and collection within the series of more than 200 successive allogeneic HSCT at our transplant center. Two hundred and seven consecutive patients who underwent allogeneic peripheral blood stem cell transplantation were included in this study. Age, sex, weight, complete blood counts, CD34 + cell counts, total collected amount of CD34 + cells, CD34 + cells per 10l processed, mobilization failure and adverse events were reviewed. Median age was 40.2±12.9 (21-68) years and 46.4±13.4 (17-67) years for donors and patients, respectively. The number of donors who had undergone adequate CD34 + cell harvesting and completed the procedure on the fourth day was 67 (32.8% of all patients). Only 12 patients required cell apheresis both on day 5 and 6. Apheresis was completed on day 4 and/or day 5 in 94.2% of all our donors. There was no significant association between CD34 + stem cell volume and age, gender and weight values of donors. Mobilization failure was not seen in our series. G-CSF is highly effective in 1/3 of the donors on the 4th day in order to collect enough number of stem cells. We propose that peripheral stem cell collection might start on day 4th of G-CSF treatment for avoiding G-CSF related side effects and complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Race as Seriality: A Response to David Benatar and Zimitri Erasmus

    Science.gov (United States)

    Gouws, A.

    2010-01-01

    In this article I draw on the Sarte's notion of "seriality" as theorized in his book "Dialectic of Reason" and as interpreted by Iris Marion Young. I argue that seriality can be used to escape the false essentialism and identity politics of race as a category for admissions to universities. A series is a social collective whose members are unified…

  4. Tevatron serial data repeater system

    International Nuclear Information System (INIS)

    Ducar, R.J.

    1981-01-01

    A ten megabit per second serial data repeater system has been developed for the 6.28km Tevatron accelerator. The repeaters are positioned at each of the thirty service buildings and accommodate control and abort system communications as well as distribution of the Tevatron time and energy clocks. The repeaters are transparent to the particular protocol of the transmissions. Serial data are encoded locally as unipolar two volt signals employing the self-clocking Manchester Bi-Phase code. The repeaters modulate the local signals to low-power bursts of 50 MHz rf carrier for the 260m transmission between service buildings. The repeaters also demodulate the transmission and restructure the data for local utilization. The employment of frequency discrimination techniques yields high immunity to the characteristic noise spectrum

  5. Nanoflow electrospinning serial femtosecond crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, Raymond G.; Laksmono, Hartawan [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Kern, Jan [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Tran, Rosalie; Hattne, Johan [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Alonso-Mori, Roberto [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Lassalle-Kaiser, Benedikt [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glöckner, Carina; Hellmich, Julia [Technische Universität Berlin, Strasse des 17 Juni 135, 10623 Berlin (Germany); Schafer, Donald W. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Sellberg, Jonas [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Stockholm University, S-106 91 Stockholm (Sweden); McQueen, Trevor A. [Stanford University, Stanford, CA 94025 (United States); Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Zwart, Petrus H. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Glatzel, Pieter [European Synchrotron Radiation Facility, Grenoble (France); Milathianaki, Despina; White, William E. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Adams, Paul D. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Williams, Garth J.; Boutet, Sébastien [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Zouni, Athina [Technische Universität Berlin, Strasse des 17 Juni 135, 10623 Berlin (Germany); Messinger, Johannes [Umeå Universitet, Umeå (Sweden); Sauter, Nicholas K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bergmann, Uwe [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); Yano, Junko; Yachandra, Vittal K. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Bogan, Michael J., E-mail: mbogan@slac.stanford.edu [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

    2012-11-01

    A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min{sup −1} to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min{sup −1} and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.

  6. Nanoflow electrospinning serial femtosecond crystallography

    International Nuclear Information System (INIS)

    Sierra, Raymond G.; Laksmono, Hartawan; Kern, Jan; Tran, Rosalie; Hattne, Johan; Alonso-Mori, Roberto; Lassalle-Kaiser, Benedikt; Glöckner, Carina; Hellmich, Julia; Schafer, Donald W.; Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W.; Sellberg, Jonas; McQueen, Trevor A.; Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien; Zwart, Petrus H.; Glatzel, Pieter; Milathianaki, Despina; White, William E.; Adams, Paul D.; Williams, Garth J.; Boutet, Sébastien; Zouni, Athina; Messinger, Johannes; Sauter, Nicholas K.; Bergmann, Uwe; Yano, Junko; Yachandra, Vittal K.; Bogan, Michael J.

    2012-01-01

    A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min −1 to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min −1 and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption

  7. Serial Austen. Mashingups with Zombies

    Directory of Open Access Journals (Sweden)

    Eleonora Federici

    2017-01-01

    Full Text Available Jane Austen sells. She sells in all possible ways, her novels have been adapted for the cinema and the stage, they have been rewritten as comics and graphic novels. Jane austen is a cultural icon. The interest in her life is so strong that many biographies have been written in order to recover new facts and details. The places where she has lived and the places depicted in her novels have become tourist sites for literary pilgrims. Austen is a cross-over phenomenon, with regency costume balls recreated in her name and an endless proliferation of her works in all media. My essay will investigate Jane Austen and Seth Grahame-Smith’s Pride and Prejudice and Zombies (2009, a mash-up novel which has become a real cultural phenomenon of the last decade and will demonstrate how it can be considered a serial narrative. If as Henry Jenkins asserts, seriality implies the unfolding of a story over time through a process of “chunking” (that is creating meaningful parts of the same story and of “dispersal” (that is breaking the story into more parts and in more genres and media, mash-ups seems to do this.  Austen’s story remains as a “story hook” which pushes the reader to come back to different products for a continuation of the same story. So, if on the one hand, seriality occurs within the same text, the story-telling of Austen’s stories across genres and media is part of a seriality process.

  8. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  9. Notorious Cases of Serial Killers

    Directory of Open Access Journals (Sweden)

    Iosub Elena-Cătălina

    2014-05-01

    Full Text Available The reconstruction of a death scene provides an overall picture of the crime and will indicate the murder as an event or one of a series of events and also the criminal. But when the criminal is declared a serial killer, many questions are raised up. How could a person kill some else without a reason or why people react in such a disorganized way and become so brutal or what made them act like that and so many questions with also so many answers. This project explains the psychology of a murderer, his own way of thinking and acting by presuming that we may accurately discover what is in their minds when they kill. It is about a very complex issue regarding murder investigations, biological factors and psychological profile of a serial killer. Dealing with this problem we will at last reach to the question that could solve finally the puzzle: ―Are serial murderers distorted reflections of society's own values?

  10. Serial murder by healthcare professionals.

    Science.gov (United States)

    Yorker, Beatrice Crofts; Kizer, Kenneth W; Lampe, Paula; Forrest, A R W; Lannan, Jacquetta M; Russell, Donna A

    2008-01-01

    The prosecution of Charles Cullen, a nurse who killed at least 40 patients over a 16-year period, highlights the need to better understand the phenomenon of serial murder by healthcare professionals. The authors conducted a LexisNexis search which yielded 90 criminal prosecutions of healthcare providers that met inclusion criteria for serial murder of patients. In addition we reviewed epidemiologic studies, toxicology evidence, and court transcripts, to provide data on healthcare professionals who have been prosecuted between 1970 and 2006. Fifty-four of the 90 have been convicted; 45 for serial murder, four for attempted murder, and five pled guilty to lesser charges. Twenty-four more have been indicted and are either awaiting trial or the outcome has not been published. The other 12 prosecutions had a variety of legal outcomes. Injection was the main method used by healthcare killers followed by suffocation, poisoning, and tampering with equipment. Prosecutions were reported from 20 countries with 40% taking place in the United States. Nursing personnel comprised 86% of the healthcare providers prosecuted; physicians 12%, and 2% were allied health professionals. The number of patient deaths that resulted in a murder conviction is 317 and the number of suspicious patient deaths attributed to the 54 convicted caregivers is 2113. These numbers are disturbing and demand that systemic changes in tracking adverse patient incidents associated with presence of a specific healthcare provider be implemented. Hiring practices must shift away from preventing wrongful discharge or denial of employment lawsuits to protecting patients from employees who kill.

  11. Serial Determination of bcl-2 Major Breakpoint Region (MBR) Rearrangement, t(14;18) (q32;q21), in the Bone Marrow and Peripheral Blood for Stages I - III Follicular Lymphoma after Central Lymphatic Irradiation (CLI) - A Preliminary Report

    International Nuclear Information System (INIS)

    Ha, C.S.; Cabanillas, F.; Lee, M.; Besa, P.C.; McLaughlin, P.W.; Cox, J.D.

    1995-01-01

    Purpose/Objective: About (2(3)) of all cases of follicular lymphoma have rearrangement of bcl-2 MBR through t(14;18) (q32;q21). This arrangement could serve as a sensitive marker for follicular lymphoma cells. The objectives of this study are two fold: 1) To assess complete molecular response rate of stages I-III follicular lymphoma to CLI by detection of PCR amplifiable bcl-2 MBR rearrangement in the bone marrow and peripheral blood before and after CLI. 2) To assess the significance of the molecular response as a prognostic indicator. Materials and Methods: 13 patients with stages I-III follicular lymphoma were treated with CLI as a part of a prospective randomized protocol comparing CLI with chemotherapy. Bone marrow and peripheral blood samples were obtained from the patients before initiation of CLI. By using the PCR technique, the DNA sequences from the bone marrow and peripheral blood samples that flank the bcl-2 MBR involved in t(14;18) (q32;q21) were amplified. For the patients who had positive PCR result, bone marrow and blood samples were followed at regular intervals during and after CLI. The patients with negative PCR result prior to CLI did not have follow-up PCR analysis. The results of the PCR amplification were correlated with clinical findings. Results: All 13 patients achieved clinical complete response after CLI. No patient has relapsed with a median follow-up period of 11 months (range 5 to 24 months). Pretreatment PCR results are available in 13 patients for peripheral blood and in 9 patients for bone marrow. (7(13)) blood and (5(9)) bone marrow samples were PCR-positive for bcl-2 MBR rearrangement. All 5 patients with positive pretreatment bone marrow also had positive pretreatment peripheral blood. (6(7)) patients with positive pretreatment blood PCR converted to negative within 2,3,5,6,6, and 10 months from the 1st day of CLI. The 7th patient has no follow-up PCR available yet. Follow-up PCR results from the pretreatment bone

  12. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgeneTM Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray

    Directory of Open Access Journals (Sweden)

    Laura Kennedy

    2008-01-01

    Full Text Available Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgeneTM RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2TM enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgeneTM blood samples also advocate a short, fixed room temperature storage time for all PAXgeneTM blood samples collected for the purposes of global transcriptional profiling in clinical studies.

  13. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgene Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray.

    Science.gov (United States)

    Kennedy, Laura; Vass, J Keith; Haggart, D Ross; Moore, Steve; Burczynski, Michael E; Crowther, Dan; Miele, Gino

    2008-08-25

    Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene() RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2() enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene() blood samples also advocate a short, fixed room temperature storage time for all PAXgene() blood samples collected for the purposes of global transcriptional profiling in clinical studies.

  14. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgene™ Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray

    Science.gov (United States)

    Kennedy, Laura; Vass, J. Keith; Haggart, D. Ross; Moore, Steve; Burczynski, Michael E.; Crowther, Dan; Miele, Gino

    2008-01-01

    Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene™ RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2™ enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene™ blood samples also advocate a short, fixed room temperature storage time for all PAXgene™ blood samples collected for the purposes of global transcriptional profiling in clinical studies. PMID:19578521

  15. Comparison of the Fenwal Amicus and Fresenius Com.Tec cell separators for autologous peripheral blood progenitor cell collection.

    Science.gov (United States)

    Altuntas, Fevzi; Kocyigit, Ismail; Ozturk, Ahmet; Kaynar, Leylagul; Sari, Ismail; Oztekin, Mehmet; Solmaz, Musa; Eser, Bulent; Cetin, Mustafa; Unal, Ali

    2007-04-01

    Peripheral blood progenitor cells (PBPC) are commonly used as a stem cell source for autologous transplantation. This study was undertaken to evaluate blood cell separators with respect to separation results and content of the harvest. Forty autologous PBPC collections in patients with hematological malignancies were performed with either the Amicus or the COM.TEC cell separators. The median product volume was lower with the Amicus compared to the COM.TEC (125 mL vs. 300 mL; p < 0.001). There was no statistically significant difference in the median number of CD34+ cell/kg in product between the Amicus and the COM.TEC (3.0 x 10(6) vs. 4.1 x 10(6); p = 0.129). There was a statistically higher mean volume of ACD used in collections on the Amicus compared to the COM.TEC (1040 +/- 241 mL vs. 868 +/- 176 mL; p = 0.019). There was a statistical difference in platelet (PLT) contamination of the products between the Amicus and the COM.TEC (0.3 x 10(11) vs. 1.1 x 10(11); p < 0.001). The median % decrease in PB PLT count was statistically higher in the COM.TEC compared to the Amicus instruments (18.5% vs. 9.5%; p = 0.028). In conclusion, both instruments collected PBPCs efficiently. However, Amicus has the advantage of lower PLT contamination in the product, and less decrease in PB platelet count with lower product volume in autologous setting.

  16. Comparison of equine platelet function and survival in whole blood collected in acid-citrate-dextrose solution or citrate-phosphate-dextrose-adenine solution.

    Science.gov (United States)

    Bozorgmanesh, Rana; Sutton-Burges, Julie W; Tablin, Fern

    2017-06-01

    Equine whole blood collection and storage methods have been evaluated to assess red blood cell viability; however, platelet (PLT) viability has not been comprehensively assessed. The purpose of the study was to compare viability of PLTs collected in whole blood into 2 different anticoagulants. Whole blood from 6 healthy adult Thoroughbred horses was collected into citrate-phosphate-dextrose-adenine (CPDA) or acid-citrate-dextrose (ACD). Platelet count, pH, and concentrations of glucose, lactate, carbon dioxide, oxygen, bicarbonate, sodium, potassium, and chloride were measured within 10 minutes of collection and then again one hour later at which time PLT aggregometry was performed to assess PLT function. Aggregometry mean amplitudes were significantly higher in CPDA compared to ACD. Blood glucose, pH, bicarbonate, sodium, and lactate concentrations were significantly higher in CPDA compared to ACD. Lactate concentration was higher following one hour in either anticoagulant. Potassium, oxygen, and carbon dioxide concentrations were significantly higher in ACD compared to CPDA at collection. Platelet aggregometry results suggest that CPDA is superior to ACD for maintaining PLT viability following whole blood collection. This may be associated with the higher, more neutral pH as well as an increase in glucose available for metabolism. Although lactate was increased in the CPDA samples it was not high enough to decrease pH and therefore may not have been high enough to cause morphologic lesions and loss of PLT viability. © 2017 American Society for Veterinary Clinical Pathology.

  17. Successful management of severe hemolytic disease of the fetus due to anti-Jsb using intrauterine transfusions with serial maternal blood donations: a case report and a review of the literature.

    Science.gov (United States)

    Al Riyami, Arwa Z; Al Salmani, Moza; Al Hashami, Sabria; Al Mahrooqi, Sabah; Al Hinai, Sumaiya; Al Balushi, Halima; Al Riyami, Nihal; Gowri, V; Al Dughaishi, Tamima; Al Hosni, Saif; Al-Khabori, Murtadha; Al-Farsi, Khalil; Al Huneini, Mohammed; Alkindi, Salam

    2014-01-01

    The management of pregnant women with anti-Jsb is challenging due to the paucity of antigen-negative blood for fetal and neonatal transfusion. A 29-year-old woman with anti-Jsb was referred for assessment of recurrent fetal losses. With the presence of the sister as a historically matched donor, she was planned for active surveillance for fetal anemia during pregnancy. The fetus remained well until 21 weeks of gestation when signs of fetal anemia and early hydrops fetalis were noted. Anti-Jsb titer was at 128. The sister's red blood cells (RBCs) were cross-match incompatible. Urgent intrauterine transfusion (IUT) was performed with washed irradiated maternal RBCs, donated after cessation of heparin. The mother was given intravenous iron (IV-Fe) and continued on weekly recombinant human erythropoietin (rHu-EPO). Repeated IUTs were needed every 1 to 3 weeks. Throughout a 7-week period, three maternal donations were performed with total donated whole blood volume of 1250 mL, supporting four IUTs. At 29 weeks of gestation, the procedure was complicated by umbilical cord hematoma necessitating urgent cesarean section. A male newborn was delivered, transfused at birth, and subsequently treated with phototherapy and five top-up transfusions. This case represents a successful example of managing hemolytic disease of the fetus due to a rare antibody using maternal blood. It also supports previous data on safety of maternal donations during pregnancy and the use of combination of rHu-EPO and IV-Fe as a supportive measure. © 2013 American Association of Blood Banks.

  18. Isolation of endothelial colony-forming cells from blood samples collected from the jugular and cephalic veins of healthy adult horses.

    Science.gov (United States)

    Sharpe, Ashley N; Seeto, Wen J; Winter, Randolph L; Zhong, Qiao; Lipke, Elizabeth A; Wooldridge, Anne A

    2016-10-01

    OBJECTIVE To evaluate optimal isolation of endothelial colony-forming cells (ECFCs) from peripheral blood of horses. SAMPLE Jugular and cephalic venous blood samples from 17 adult horses. PROCEDURES Each blood sample was divided; isolation was performed with whole blood adherence (WBA) and density gradient centrifugation (DGC). Isolated cells were characterized by uptake of 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate-labeled acetylated low-density lipoprotein (DiI-Ac-LDL), vascular tubule formation, and expression of endothelial (CD34, CD105, vascular endothelial growth factor receptor-2, and von Willebrand factor) and hematopoietic (CD14) cell markers by use of indirect immunofluorescence assay (IFA) and flow cytometry. RESULTS Colonies with cobblestone morphology were isolated from 15 of 17 horses. Blood collected from the cephalic vein yielded colonies significantly more often (14/17 horses) than did blood collected from the jugular vein (8/17 horses). Of 14 cephalic blood samples with colonies, 13 were obtained with DGC and 8 with WBA. Of 8 jugular blood samples with colonies, 8 were obtained with DGC and 4 with WBA. Colony frequency (colonies per milliliter of blood) was significantly higher for cephalic blood samples and samples isolated with DGC. Cells formed vascular tubules, had uptake of DiI-Ac-LDL, and expressed endothelial markers by use of IFA and flow cytometry, which confirmed their identity as ECFCs. CONCLUSIONS AND CLINICAL RELEVANCE Maximum yield of ECFCs was obtained for blood samples collected from both the jugular and cephalic veins and use of DGC to isolate cells. Consistent yield of ECFCs from peripheral blood of horses will enable studies to evaluate diagnostic and therapeutic uses.

  19. Autologous peripheral blood stem cell harvest: Collection efficiency and factors affecting it

    Directory of Open Access Journals (Sweden)

    Aseem K Tiwari

    2016-01-01

    Full Text Available Background: Harvest of hematopoietic progenitor cells via leukapheresis is being used increasingly for transplants in India. Adequate yield of cells per kilogram body weight of recipient is required for successful engraftment. Collection efficiency (CE is an objective quality parameter used to assess the quality of leukapheresis program. In this study, we calculated the CE of the ComTec cell separator (Fresenius Kabi, Germany using two different formulae (CE1 and CE2 and analyzed various patient and procedural factors, which may affect it. Materials and Methods: One hundred and one consecutive procedures in 77 autologous donors carried out over 3 years period were retrospectively reviewed. Various characteristics like gender, age, weight, disease status, hematocrit, preprocedure total leukocyte count, preprocedure CD34 positive (CD34+ cells count, preprocedure absolute CD34+ cell count and processed apheresis volume effect on CE were compared. CE for each procedure was calculated using two different formulae, and results were compared using statistical correlation and regression analysis. Results: The mean CE1 and CE2 was 41.2 and 49.1, respectively. CE2 appeared to be more accurate indicator of overall CE as it considered the impact of continued mobilization of stem cells during apheresis procedure, itself. Of all the factors affecting CE, preprocedure absolute CD34+ was the only independent factor affecting CE. Conclusion: The only factor affecting CE was preprocedure absolute CD34+ cells. Though the mean CE2 was higher than CE1, it was not statistically significant.

  20. Correlating tumor metabolic progression index measured by serial FDG PET-CT, apparent diffusion coefficient measured by magnetic resonance imaging (MRI) and blood genomics to patient’s outcome in advanced colorectal cancer: the CORIOLAN study

    International Nuclear Information System (INIS)

    Deleporte, Amelie; Charette, Nicolas; Machiels, Godelieve; Piccart, Martine; Flamen, Patrick; Hendlisz, Alain; Paesmans, Marianne; Garcia, Camilo; Vandeputte, Caroline; Lemort, Marc; Engelholm, Jean-Luc; Hoerner, Frederic; Aftimos, Philippe; Awada, Ahmad

    2014-01-01

    Metastatic colorectal cancer (mCRC) may present various behaviours that define different courses of tumor evolution. There is presently no available tool designed to assess tumor aggressiveness, despite the fact that this is considered to have a major impact on patient outcome. CORIOLAN is a single-arm prospective interventional non-therapeutic study aiming mainly to assess the natural tumor metabolic progression index (TMPI) measured by serial FDG PET-CT without any intercurrent antitumor therapy as a prognostic factor for overall survival (OS) in patients with mCRC. Secondary objectives of the study aim to test the TMPI as a prognostic marker for progression-free survival (PFS), to assess the prognostic value of baseline tumor FDG uptake on PFS and OS, to compare TMPI to classical clinico-biological assessment of prognosis, and to test the prognostic value on OS and PFS of MRI-based apparent diffusion coefficient (ADC) and variation of vADC using voxel-based diffusion maps. Additionally, this study intends to identify genomic and epigenetic factors that correlate with progression of tumors and the OS of patients with mCRC. Consequently, this analysis will provide information about the signaling pathways that determine the natural and therapy-free course of the disease. Finally, it would be of great interest to investigate whether in a population of patients with mCRC, for which at present no known effective therapy is available, tumor aggressiveness is related to elevated levels of circulating tumor cells (CTCs) and to patient outcome. Tumor aggressiveness is one of the major determinants of patient outcome in advanced disease. Despite its importance, supported by findings reported in the literature of extreme outcomes for patients with mCRC treated with chemotherapy, no objective tool allows clinicians to base treatment decisions on this factor. The CORIOLAN study will characterize TMPI using FDG-PET-based metabolic imaging of patients with chemorefractory m

  1. Serial position learning in honeybees.

    Directory of Open Access Journals (Sweden)

    Randolf Menzel

    Full Text Available Learning of stimulus sequences is considered as a characteristic feature of episodic memory since it contains not only a particular item but also the experience of preceding and following events. In sensorimotor tasks resembling navigational performance, the serial order of objects is intimately connected with spatial order. Mammals and birds develop episodic(-like memory in serial spatio-temporal tasks, and the honeybee learns spatio-temporal order when navigating between the nest and a food source. Here I examine the structure of the bees' memory for a combined spatio-temporal task. I ask whether discrimination and generalization are based solely on simple forms of stimulus-reward learning or whether they require sequential configurations. Animals were trained to fly either left or right in a continuous T-maze. The correct choice was signaled by the sequence of colors (blue, yellow at four positions in the access arm. If only one of the possible 4 signals is shown (either blue or yellow, the rank order of position salience is 1, 2 and 3 (numbered from T-junction. No learning is found if the signal appears at position 4. If two signals are shown, differences at positions 1 and 2 are learned best, those at position 3 at a low level, and those at position 4 not at all. If three or more signals are shown these results are corroborated. This salience rank order again appeared in transfer tests, but additional configural phenomena emerged. Most of the results can be explained with a simple model based on the assumption that the four positions are equipped with different salience scores and that these add up independently. However, deviations from the model are interpreted by assuming stimulus configuration of sequential patterns. It is concluded that, under the conditions chosen, bees rely most strongly on memories developed during simple forms of associative reward learning, but memories of configural serial patterns contribute, too.

  2. Transcriptome data of peripheral white blood cells from beef heifers collected at the time of artificial insemination

    Directory of Open Access Journals (Sweden)

    Sarah E. Dickinson

    2018-06-01

    Full Text Available The reproductive performance of heifers within their first breeding season influences the success of beef cattle operations. Therefore, a means to identify infertile and late breeding heifers before the start of the breeding season holds great promise for the future of the beef industry. Pubertal beef heifers were subjected to estrous synchronization and fixed time artificial insemination (FTAI. We collected peripheral blood from the heifers at the time of artificial insemination (AI and generated RNA sequencing data to characterize the transcriptome of peripheral white blood cells (PWBC. Following insemination, heifers were exposed to natural service for a defined breeding season, and pregnancy was evaluated to classify heifers into one of three groups: AI-pregnant, natural-bred (NB pregnant, and non-pregnant. The raw transcriptome data of PWBC is available on the NCBI GEO repository (GSE103628 where the reader can also find raw read counts and normalized gene expression data. The normalized data on transcript coverage can be visualized as a genome browser at HeiferFertilityRNAseq.org. Keywords: Biomarkers, Infertility, Pregnancy

  3. Nanoflow electrospinning serial femtosecond crystallography

    Science.gov (United States)

    Sierra, Raymond G.; Laksmono, Hartawan; Kern, Jan; Tran, Rosalie; Hattne, Johan; Alonso-Mori, Roberto; Lassalle-Kaiser, Benedikt; Glöckner, Carina; Hellmich, Julia; Schafer, Donald W.; Echols, Nathaniel; Gildea, Richard J.; Grosse-Kunstleve, Ralf W.; Sellberg, Jonas; McQueen, Trevor A.; Fry, Alan R.; Messerschmidt, Marc M.; Miahnahri, Alan; Seibert, M. Marvin; Hampton, Christina Y.; Starodub, Dmitri; Loh, N. Duane; Sokaras, Dimosthenis; Weng, Tsu-Chien; Zwart, Petrus H.; Glatzel, Pieter; Milathianaki, Despina; White, William E.; Adams, Paul D.; Williams, Garth J.; Boutet, Sébastien; Zouni, Athina; Messinger, Johannes; Sauter, Nicholas K.; Bergmann, Uwe; Yano, Junko; Yachandra, Vittal K.; Bogan, Michael J.

    2012-01-01

    An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min−1 to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min−1 and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption. PMID:23090408

  4. Serial transrectal ultrasonography for monitoring the reproductive activity of the Asiatic black bear (Ursus thibetanus ussuricus).

    Science.gov (United States)

    Kang, H G; Jeong, D H; Yang, J J; Lee, B K; Kong, J K; Lee, J W; Kim, I H

    2015-02-01

    This study evaluated the structural changes in the reproductive tract of Asiatic black bears using serial transrectal ultrasonography. In addition, the ultrasonographic observations were compared with the results of vaginal cytology and hormonal analyses. The collection of blood for hormonal analysis, vaginal cytology and transrectal ultrasonography was performed in two bears (Bears 1 and 2) from June 2011 to August 2013 without mating and in a third bear (Bear 3) from April to December 2012, allowing natural mating. Serial ultrasonographic observations showed cyclic changes in ovarian structures (e.g. emergence of small follicles, growth and ovulation of dominant follicles and corpus luteum (CL) formation) during the reproductive cycles of the three bears. The diameter of the uterine horns remained similar throughout the reproductive cycle in Bears 1 and 2, and it remained similar from April until October, but an enlargement containing foetuses was observed in Bear 3 in December. The ultrasonographic observations were consistent with the data obtained through vaginal cytology and progesterone analysis during the reproductive cycle. An average of 4.0 (±0.4) dominant follicles was observed during the oestrous stage (May-August), during which the superficial cells accounted for >90% of the total vaginal cells. In addition, the detection of an average of 2.6 (±0.2) CL was associated with increased plasma progesterone concentrations (3.0 ± 0.4 ng/ml) between June and December (near hibernation). In conclusion, serial transrectal ultrasonography demonstrated yearly oestrous (ovulation) cycles via follicular dynamics and CL formation on ovaries, accordingly with vaginal cytology and hormonal level in the Asiatic black bear. © 2014 Blackwell Verlag GmbH.

  5. Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

    Science.gov (United States)

    Bachmann, Karin; Kutter, Annette Pn; Schefer, Rahel Jud; Marly-Voquer, Charlotte; Sigrist, Nadja

    2017-08-01

    Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

  6. SMALL SERIAL AND SERIAL PRODUCTION MANAGEMENT IN UNSTABLE DEMAND ENVIROUMENT

    Directory of Open Access Journals (Sweden)

    Tsomaeva I. V.

    2014-03-01

    Full Text Available The work presents the methodological approach to production program of the enterprise serial engineering for the current period in the conditions of uncertainty of demand. Here are two problems with this. The first is connected with the formation of the production program of the next quarter, year. Objective could be to stochastic programming, but this task is difficult. Therefore, in this paper we proposed a simple solution. On the basis of statistical historical information about the deviation of actual sales data products from predicted by Monte Carlo generated a lot of production programs. Fixed worst key performance (sales, profit etc. The difference between the values of the planned target and the settlement defines stochastic reserve, to be established at the expense of additional innovations. The second problem is connected with the formation of the production program production in the planned month, taking into account the creation of stocks of production in the conditions when for a short period of time is difficult to build a pattern of change in the quantity demanded by month for serial production, as in some months of the year the products are not produced nor sold. To justify the level of inventories of finished products is information on deviations from the fact plan for past periods. Built function of frequency distribution of the values of deviations. This allows you to further build the methodology for determining the level of production (taking into account the reserves and sales of products that deliver maximum economic effect from the sales in the conditions of a random process of realization of production.

  7. Criminal psychological profiling of serial arson crimes.

    Science.gov (United States)

    Kocsis, Richard N; Cooksey, Ray W

    2002-12-01

    The practice of criminal psychological profiling is frequently cited as being applicable to serial arson crimes. Despite this claim, there does not appear to be any empirical research that examines serial arson offence behaviors in the context of profiling. This study seeks to develop an empirical model of serial arsonist behaviors that can be systematically associated with probable offender characteristics. Analysis has produced a model of offence behaviors that identify four discrete behavior patterns, all of which share a constellation of common nondiscriminatory behaviors. The inherent behavioral themes of each of these patterns are explored with discussion of their broader implications for our understanding of serial arson and directions for future research.

  8. Viscous hydrophilic injection matrices for serial crystallography

    Directory of Open Access Journals (Sweden)

    Gabriela Kovácsová

    2017-07-01

    Full Text Available Serial (femtosecond crystallography at synchrotron and X-ray free-electron laser (XFEL sources distributes the absorbed radiation dose over all crystals used for data collection and therefore allows measurement of radiation damage prone systems, including the use of microcrystals for room-temperature measurements. Serial crystallography relies on fast and efficient exchange of crystals upon X-ray exposure, which can be achieved using a variety of methods, including various injection techniques. The latter vary significantly in their flow rates – gas dynamic virtual nozzle based injectors provide very thin fast-flowing jets, whereas high-viscosity extrusion injectors produce much thicker streams with flow rates two to three orders of magnitude lower. High-viscosity extrusion results in much lower sample consumption, as its sample delivery speed is commensurate both with typical XFEL repetition rates and with data acquisition rates at synchrotron sources. An obvious viscous injection medium is lipidic cubic phase (LCP as it is used for in meso membrane protein crystallization. However, LCP has limited compatibility with many crystallization conditions. While a few other viscous media have been described in the literature, there is an ongoing need to identify additional injection media for crystal embedding. Critical attributes are reliable injection properties and a broad chemical compatibility to accommodate samples as heterogeneous and sensitive as protein crystals. Here, the use of two novel hydrogels as viscous injection matrices is described, namely sodium carboxymethyl cellulose and the thermo-reversible block polymer Pluronic F-127. Both are compatible with various crystallization conditions and yield acceptable X-ray background. The stability and velocity of the extruded stream were also analysed and the dependence of the stream velocity on the flow rate was measured. In contrast with previously characterized injection media, both new

  9. Efficient collection of peripheral blood stem cells using the Fresenius AS104 in chronic myelocytic leukemia patients with very high numbers of platelets.

    Science.gov (United States)

    Komatsu, F; Ishida, Y

    1997-04-01

    For chronic myelocytic leukemia patients with very high numbers of platelets, we describe an efficient method for the collection of peripheral blood stem cells (PBSC) using the Fresenius AS104 cell separator. In these patients, it is difficult to collect a sufficient number of PBSC, due to the platelet band interfering with the machine's red cell interface sensor. We, therefore, tried a manual adjustment of the device. The collection phase was set automatically. When the whole blood began to separate into the red cell layer and plasma (plus mononuclear cell) layer, the red cell interface setting of "7:1" was changed to "OFF," and the plasma pump flow rate was controlled manually in order to locate the interface position 1 cm from the outside wall of the centrifuge chamber. After the collection phase, the procedure was returned to the automatic setting. By repeating this procedure, we were able to collect large numbers of PBSC.

  10. Whole-pattern fitting technique in serial femtosecond nanocrystallography

    Directory of Open Access Journals (Sweden)

    Ruben A. Dilanian

    2016-03-01

    Full Text Available Serial femtosecond X-ray crystallography (SFX has created new opportunities in the field of structural analysis of protein nanocrystals. The intensity and timescale characteristics of the X-ray free-electron laser sources used in SFX experiments necessitate the analysis of a large collection of individual crystals of variable shape and quality to ultimately solve a single, average crystal structure. Ensembles of crystals are commonly encountered in powder diffraction, but serial crystallography is different because each crystal is measured individually and can be oriented via indexing and merged into a three-dimensional data set, as is done for conventional crystallography data. In this way, serial femtosecond crystallography data lie in between conventional crystallography data and powder diffraction data, sharing features of both. The extremely small sizes of nanocrystals, as well as the possible imperfections of their crystallite structure, significantly affect the diffraction pattern and raise the question of how best to extract accurate structure-factor moduli from serial crystallography data. Here it is demonstrated that whole-pattern fitting techniques established for one-dimensional powder diffraction analysis can be feasibly extended to higher dimensions for the analysis of merged SFX diffraction data. It is shown that for very small crystals, whole-pattern fitting methods are more accurate than Monte Carlo integration methods that are currently used.

  11. Field Evaluation of Capillary Blood Samples as a Collection Specimen for the Rapid Diagnosis of Ebola Virus Infection During an Outbreak Emergency.

    Science.gov (United States)

    Strecker, Thomas; Palyi, Bernadett; Ellerbrok, Heinz; Jonckheere, Sylvie; de Clerck, Hilde; Bore, Joseph Akoi; Gabriel, Martin; Stoecker, Kilian; Eickmann, Markus; van Herp, Michel; Formenty, Pierre; Di Caro, Antonino; Becker, Stephan

    2015-09-01

    Reliable reverse transcription polymerase chain reaction (RT-PCR)-based diagnosis of Ebola virus infection currently requires a blood sample obtained by intravenous puncture. During the current Ebola outbreak in Guinea, we evaluated the usability of capillary blood samples collected from fingersticks of patients suspected of having Ebola virus disease (EVD) for field diagnostics during an outbreak emergency. A total of 120 venous and capillary blood samples were collected from 53 patients admitted to the Ebola Treatment Centre in Guéckédou, Guinea, between July and August 2014. All sample specimens were analyzed by RT-PCR using the RealStar Filovirus Screen RT-PCR Kit 1.0 from altona Diagnostics (Germany). We compared samples obtained by venipuncture and those obtained by capillary blood sampling absorbed onto swab devices. The resulting sensitivity and specificity of tests performed with capillary blood samples were 86.8% (95% confidence interval [CI], 71.9%-95.6%; 33/38 patients) and 100% (95% CI, 84.6%-100%; 22/22 patients), respectively. Our data suggest that capillary blood samples could serve as an alternative to venous blood samples for the diagnosis of EVD in resource-limited settings during a crisis. This can be of particular advantage in cases when venipuncture is difficult to perform-for example, with newborns and infants or when adult patients reject venipuncture for cultural or religious reasons. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America.

  12. Scientific and Technical Serials Holdings Optimization in an Inefficient Market: A LSU Serials Redesign Project Exercise.

    Science.gov (United States)

    Bensman, Stephen J.; Wilder, Stanley J.

    1998-01-01

    Analyzes the structure of the library market for scientific and technical (ST) serials. Describes an exercise aimed at a theoretical reconstruction of the ST-serials holdings of Louisiana State University (LSU) Libraries. Discusses the set definitions, measures, and algorithms necessary in the design of a computer program to appraise ST serials.…

  13. Serial Position Functions in General Knowledge

    Science.gov (United States)

    Kelley, Matthew R.; Neath, Ian; Surprenant, Aimée M.

    2015-01-01

    Serial position functions with marked primacy and recency effects are ubiquitous in episodic memory tasks. The demonstrations reported here explored whether bow-shaped serial position functions would be observed when people ordered exemplars from various categories along a specified dimension. The categories and dimensions were: actors and age;…

  14. The Serial Murderer's Motivations: An Interdisciplinary Review.

    Science.gov (United States)

    DeHart, Dana D.; Mahoney, John M.

    1994-01-01

    Defines serial killer as individual who murders two or more victims over an extended period of time, ranging from days to years, with the crimes often being sexually motivated. Reviews existing motivational theories of serial murder and proposes additional explications from range of disciplines. Presents suggestions for future research and…

  15. Modus operandi of female serial killers.

    Science.gov (United States)

    Wilson, W; Hilton, T

    1998-04-01

    The modus operandi of female serial killers was examined from a chronology of 58 cases in America and 47 cases in 17 other countries, compiled over 25-year intervals. Female serial killers in other countries accounted for a disproportionately greater number of victims, but those in America managed a longer killing career when associated with a low profile modus operandi.

  16. Female serial killing: review and case report.

    Science.gov (United States)

    Frei, Andreas; Völlm, Birgit; Graf, Marc; Dittmann, Volker

    2006-01-01

    Single homicide committed by women is rare. Serial killing is very infrequent, and the perpetrators are usually white, intelligent males with sadistic tendencies. Serial killing by women has, however, also been described. To conduct a review of published literature on female serial killers and consider its usefulness in assessing a presenting case. A literature review was conducted, after searching EMBASE, MEDLINE and PsycINFO. The presenting clinical case is described in detail in the context of the literature findings. Results The literature search revealed few relevant publications. Attempts to categorize the phenomenon of female serial killing according to patterns of and motives for the homicides have been made by some authors. The most common motive identified was material gain or similar extrinsic gratification while the 'hedonistic' sadistic or sexual serial killer seems to be extremely rare in women. There is no consistent theory of serial killing by women, but psychopathic personality traits and abusive childhood experiences have consistently been observed. The authors' case did not fit the description of a 'typical' female serial killer. In such unusual circumstances as serial killing by a woman, detailed individual case formulation is required to make sense of the psychopathology in each case. Publication of cases in scientific journals should be encouraged to advance our understanding of this phenomenon. Copyright (c) 2006 John Wiley & Sons, Ltd.

  17. Surface characterization and free thyroid hormones response of chemically modified poly(ethylene terephthalate) blood collection tubes

    Science.gov (United States)

    Jalali Dil, Ebrahim; Kim, Samuel C.; Saffar, Amir; Ajji, Abdellah; Zare, Richard N.; Sattayapiwat, Annie; Esguerra, Vanessa; Bowen, Raffick A. R.

    2018-06-01

    The surface chemistry and surface energy of chemically modified polyethylene terephthalate (PET) blood collection tubes (BCTs) were studied and the results showed a significant increase in hydrophilicity and polarity of modified PET surface. The surface modification created nanometer-sized, needle-like asperities through molecular segregation at the surface. The surface dynamics of the modified PET was examined by tracking its surface properties over a 280-day period. The results showed surface rearrangement toward a surface with lower surface energy and fewer nanometer-sized asperities. Thromboelastography (TEG) was used to evaluate and compare the thrombogenicity of the inner walls of various types of BCTs. The TEG tracings and data from various types of BCTs demonstrated differences in the reactionand coagulation times but not in clot strength. The performance of the modified tubes in free triiodothyronine (FT3) and free thyroxine (FT4) hormone tests was examined, and it was found that the interference of modified PET tubes was negligible compared to that of commercially available PET BCTs.

  18. Impact of Angiotensin Type 1A Receptors in Principal Cells of the Collecting Duct on Blood Pressure and Hypertension.

    Science.gov (United States)

    Chen, Daian; Stegbauer, Johannes; Sparks, Matthew A; Kohan, Donald; Griffiths, Robert; Herrera, Marcela; Gurley, Susan B; Coffman, Thomas M

    2016-06-01

    The main actions of the renin-angiotensin system to control blood pressure (BP) are mediated by the angiotensin type 1 receptors (AT1Rs). The major murine AT1R isoform, AT1AR, is expressed throughout the nephron, including the collecting duct in both principal and intercalated cells. Principal cells play the major role in sodium and water reabsorption. Although aldosterone is considered to be the dominant regulator of sodium reabsorption by principal cells, recent studies suggest a role for direct actions of AT1R. To specifically examine the contributions of AT1AR in principal cells to BP regulation and the development of hypertension in vivo, we generated inbred 129/SvEv mice with deletion of AT1AR from principal cells (PCKO). At baseline, we found that BPs measured by radiotelemetry were similar between PCKOs and controls. During 1-week of low-salt diet (hypertension, there was a modest but significant attenuation of hypertension in PCKOs (163±6 mm Hg) compared with controls (178±2 mm Hg; Phypertension and epithelial sodium channel activation. © 2016 American Heart Association, Inc.

  19. Reframing Serial Murder Within Empirical Research.

    Science.gov (United States)

    Gurian, Elizabeth A

    2017-04-01

    Empirical research on serial murder is limited due to the lack of consensus on a definition, the continued use of primarily descriptive statistics, and linkage to popular culture depictions. These limitations also inhibit our understanding of these offenders and affect credibility in the field of research. Therefore, this comprehensive overview of a sample of 508 cases (738 total offenders, including partnered groups of two or more offenders) provides analyses of solo male, solo female, and partnered serial killers to elucidate statistical differences and similarities in offending and adjudication patterns among the three groups. This analysis of serial homicide offenders not only supports previous research on offending patterns present in the serial homicide literature but also reveals that empirically based analyses can enhance our understanding beyond traditional case studies and descriptive statistics. Further research based on these empirical analyses can aid in the development of more accurate classifications and definitions of serial murderers.

  20. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus

    OpenAIRE

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E.; Elkins, William; Nardone, Glenn A.; Emerson, Suzanne U.; Purcell, Robert H.

    2007-01-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper disks from freshly killed deer. The disks were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of b...

  1. Serial killers with military experience: applying learning theory to serial murder.

    Science.gov (United States)

    Castle, Tammy; Hensley, Christopher

    2002-08-01

    Scholars have endeavored to study the motivation and causality behind serial murder by researching biological, psychological, and sociological variables. Some of these studies have provided support for the relationship between these variables and serial murder. However, the study of serial murder continues to be an exploratory rather than explanatory research topic. This article examines the possible link between serial killers and military service. Citing previous research using social learning theory for the study of murder, this article explores how potential serial killers learn to reinforce violence, aggression, and murder in military boot camps. As with other variables considered in serial killer research, military experience alone cannot account for all cases of serial murder. Future research should continue to examine this possible link.

  2. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    Science.gov (United States)

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  3. Serial powering of pixel modules

    International Nuclear Information System (INIS)

    Stockmanns, Tobias; Fischer, Peter; Huegging, Fabian; Peric, Ivan; Runolfsson, O.; Wermes, Norbert

    2003-01-01

    Modern pixel detectors for the next generation of high-energy collider experiments like LHC use readout electronics in deep sub-micron technology. Chips in this technology need a low supply voltage of 2-2.5 V alongside high current consumption to achieve the desired performance. The high supply current leads to significant voltage drops in the long and low mass supply cables so that voltage fluctuations at the chips are induced, when the supply current changes. This problem scales with the number of modules when connected in parallel to the power supplies. An alternative powering scheme connects several modules in series resulting in a higher supply voltage but a lower current consumption of the chain and therefore a much lower voltage drop in the cables. In addition the amount of cables needed to supply the detector is vastly reduced. The concept and features of serial powering are presented and studies of the implementation of this technology as an alternative for the ATLAS pixel detector are shown. In particular, it is shown that the potential risk of powering in series can be addressed and eliminated

  4. Serial powering of pixel modules

    CERN Document Server

    Stockmanns, Tobias; Hügging, Fabian Georg; Peric, I; Runólfsson, O; Wermes, Norbert

    2003-01-01

    Modern pixel detectors for the next generation of high-energy collider experiments like LHC use readout electronics in deep sub- micron technology. Chips in this technology need a low supply voltage of 2-2.5 V alongside high current consumption to achieve the desired performance. The high supply current leads to significant voltage drops in the long and low mass supply cables so that voltage fluctuations at the chips are induced, when the supply current changes. This problem scales with the number of modules when connected in parallel to the power supplies. An alternative powering scheme connects several modules in series resulting in a higher supply voltage but a lower current consumption of the chain and therefore a much lower voltage drop in the cables. In addition the amount of cables needed to supply the detector is vastly reduced. The concept and features of serial powering are presented and studies of the implementation of this technology as an alternative for the ATLAS pixel detector are shown. In par...

  5. Positive Reinforcement Training for Blood Collection in Grizzly Bears (Ursus arctos horribilis) Results in Undetectable Elevations in Serum Cortisol Levels: A Preliminary Investigation.

    Science.gov (United States)

    Joyce-Zuniga, Nicole M; Newberry, Ruth C; Robbins, Charles T; Ware, Jasmine V; Jansen, Heiko T; Nelson, O Lynne

    2016-01-01

    Training nonhuman animals in captivity for participation in routine husbandry procedures is believed to produce a lower stress environment compared with undergoing a general anesthetic event for the same procedure. This hypothesis rests largely on anecdotal evidence that the captive subjects appear more relaxed with the trained event. Blood markers of physiological stress responses were evaluated in 4 captive grizzly bears (Ursus arctos horribilis) who were clicker-trained for blood collection versus 4 bears who were chemically immobilized for blood collection. Serum cortisol and immunoglobulin A (IgA) and plasma β-endorphin were measured as indicators of responses to stress. Plasma β-endorphin was not different between the groups. Serum IgA was undetectable in all bears. Serum cortisol was undetectable in all trained bears, whereas chemically immobilized bears had marked cortisol elevations (p bears with extensive recent immobilization experience. These findings support the use of positive reinforcement training for routine health procedures to minimize anxiety.

  6. Serial radionuclide quantitative function studies for evaluation of renal transplants

    International Nuclear Information System (INIS)

    Martin, D.C.; Hunter, J.L.; Lawton, M.B.; Berke, R.A.; Morton, M.E.

    1974-01-01

    A new method of assessing renal function following transplantation has been presented. The calculated rate of transfer to the kidney expressed as percent per minute, effective renal blood flow in milliliters per minute and the percentage of the dose in the urine at 20 minutes are calculated from data derived from a scintillation probe over the heart following a single injection of radiohippuran. These indices provide a means of interpreting serial determinations of renal function in states in which the more conventional parameters of renal function are not reliable. (U.S.)

  7. Pediatric peripheral blood progenitor cell collection: haemonetics MCS 3P versus COBE Spectra versus Fresenius AS104.

    Science.gov (United States)

    Bambi, F; Faulkner, L B; Azzari, C; Gelli, A M; Tamburini, A; Tintori, V; Lippi, A A; Tucci, F; Bernini, G; Genovese, F

    1998-01-01

    An increasing number of apheresis machines are becoming available for peripheral blood progenitor cell (PBPC) collection in children. At the Children's Hospital of Florence (Italy), three apheresis machines were evaluated: MCS 3P (Haemonetics) (10 procedures in 4 patients, aged 10-12 years, weight 23.5-64 kg), Spectra, (COBE) (8 procedures in 3 patients, aged 4-17 years, weight 19-59 kg), and AS104 (Fresenius) (24 procedures in 9 patients, aged 2-16 years, weight 13.6-60 kg). For PBPC quantitative analysis, CD34 cytofluorimetry was employed. Relevant variables analyzed included efficiency of CD34+ cell extraction and enrichment, mononuclear cell purity and red cell contamination of the apheresis components, and platelet count decreases after leukapheresis. No significant differences in CD34+ cell-extraction abilities were found. However, the AS104 provided consistently purer leukapheresis components in terms of mononuclear cell and CD34+ cell enrichment (441 +/- 59%, vs. 240 +/- 35% and 290 +/- 42% for MCS 3P and Spectra, respectively). Postapheresis platelet counts dropped the least with the AS104. The smallest patient who underwent apheresis with MCS 3P (the only machine working on discontinuous flow and hence with greater volume shifts) weighed 23.5 kg and tolerated the procedure well, with no signs of hemodynamic instability. No significant complications were observed. All machines seem to have comparable PBPC extraction efficiency, but the AS104 seems to give the component with the greatest PBPC enrichment. This feature might be relevant for further ex vivo cell processing (CD34+ cell selection, expansion, and so on).

  8. The Productivity Advantage of Serial Entrepreneurs

    DEFF Research Database (Denmark)

    Shaw, Kathryn L.; Sørensen, Anders

    Serial entrepreneurs, who open more than one business, are found to have higher sales and higher productivity than novice entrepreneurs, who open one business. Using panel data on entrepreneurs and their firms from Denmark for 2001-2013, the serial entrepreneur has 67% higher sales than the novice......, but also opens firms that are larger in terms of the initial capital and labor, and thus is 39% more productive. There are subsets of firms that perform especially well – serial entrepreneurs that hold a portfolio of overlapping ongoing firms perform the best, as do those that open as limited liability...

  9. The American Serialization of Lord Jim

    Directory of Open Access Journals (Sweden)

    Stephen Donovan

    2017-12-01

    Full Text Available This essay presents the discovery of the American serialization of Joseph Conrad’s Lord Jim in New York’s Evening Telegram in 1903. This ‘lost’ serialization, it argues, invites a new perspective on Conrad’s early career by foregrounding the role of newspaper serialization and syndication in establishing his literary standing. After surveying the principal differences in the respective reading experiences of the periodical versus the book, it concludes by proposing that the prominence of women among Conrad’s first audiences requires us to reassess the basis for his success in North America and elsewhere.

  10. Lipidic cubic phase serial millisecond crystallography using synchrotron radiation

    Directory of Open Access Journals (Sweden)

    Przemyslaw Nogly

    2015-03-01

    Full Text Available Lipidic cubic phases (LCPs have emerged as successful matrixes for the crystallization of membrane proteins. Moreover, the viscous LCP also provides a highly effective delivery medium for serial femtosecond crystallography (SFX at X-ray free-electron lasers (XFELs. Here, the adaptation of this technology to perform serial millisecond crystallography (SMX at more widely available synchrotron microfocus beamlines is described. Compared with conventional microcrystallography, LCP-SMX eliminates the need for difficult handling of individual crystals and allows for data collection at room temperature. The technology is demonstrated by solving a structure of the light-driven proton-pump bacteriorhodopsin (bR at a resolution of 2.4 Å. The room-temperature structure of bR is very similar to previous cryogenic structures but shows small yet distinct differences in the retinal ligand and proton-transfer pathway.

  11. Serial murder in America: case studies of seven offenders.

    Science.gov (United States)

    Beasley, James O

    2004-01-01

    This article summarizes and compares information on seven interviewed serial killers in an ongoing project designed to study similarities and differences among these individuals. The aim of this article is to increase our collective knowledge of the dynamics of serial murder by examining the perpetrators' backgrounds, as well as the unique ways in which they view themselves and the world around them. Although qualitative interview research alone is not sufficient to fully understand such behavior, it is useful in many ways. Some of the information discussed based on the seven offenders interviewed is compared with broader epidemiological studies, and the strengths and limitations of each type of research are discussed. Published in 2004 by John Wiley & Sons, Ltd.

  12. Some Considerations on Seriality and Synchronicity

    OpenAIRE

    Elena Nechita

    2010-01-01

    This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  13. Some Considerations on Seriality and Synchronicity

    Directory of Open Access Journals (Sweden)

    Elena Nechita

    2010-01-01

    Full Text Available This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  14. Serial-omics characterization of equine urine.

    Directory of Open Access Journals (Sweden)

    Min Yuan

    Full Text Available Horse urine is easily collected and contains molecules readily measurable using mass spectrometry that can be used as biomarkers representative of health, disease or drug tampering. This study aimed at analyzing microliter levels of horse urine to purify, identify and quantify proteins, polar metabolites and non-polar lipids. Urine from a healthy 12 year old quarter horse mare on a diet of grass hay and vitamin/mineral supplements with limited pasture access was collected for serial-omics characterization. The urine was treated with methyl tert-butyl ether (MTBE and methanol to partition into three distinct layers for protein, non-polar lipid and polar metabolite content from a single liquid-liquid extraction and was repeated two times. Each layer was analyzed by high performance liquid chromatography-high resolution tandem mass spectrometry (LC-MS/MS to obtain protein sequence and relative protein levels as well as identify and quantify small polar metabolites and lipids. The results show 46 urine proteins, many related to normal kidney function, structural and circulatory proteins as well as 474 small polar metabolites but only 10 lipid molecules. Metabolites were mostly related to urea cycle and ammonia recycling as well as amino acid related pathways, plant diet specific molecules, etc. The few lipids represented triglycerides and phospholipids. These data show a complete mass spectrometry based-omics characterization of equine urine from a single 333 μL mid-stream urine aliquot. These omics data help serve as a baseline for healthy mare urine composition and the analyses can be used to monitor disease progression, health status, monitor drug use, etc.

  15. The post-occipital spinal venous sinus of the Nile crocodile (Crocodylus niloticus: Its anatomy and use for blood sample collection and intravenous infusions

    Directory of Open Access Journals (Sweden)

    Jan G. Myburgh

    2014-05-01

    Full Text Available The post-occipital sinus of the spinal vein is often used for the collection of blood samples from crocodilians. Although this sampling method has been reported for several crocodilian species, the technique and associated anatomy has not been described in detail in any crocodilian, including the Nile crocodile (Crocodylus niloticus. The anatomy of the cranial neck region was investigated macroscopically, microscopically, radiographically and by means of computed tomography. Latex was injected into the spinal vein and spinal venous sinus of crocodiles to visualise the regional vasculature. The spinal vein ran within the vertebral canal, dorsal to and closely associated with the spinal cord and changed into a venous sinus cranially in the post-occipital region. For blood collection, the spinal venous sinus was accessed through the interarcuate space between the atlas and axis (C1 and C2 by inserting a needle angled just off the perpendicular in the midline through the craniodorsal cervical skin, just cranial to the cranial borders of the first cervical osteoderms. The most convenient method of blood collection was with a syringe and hypodermic needle. In addition, the suitability of the spinal venous sinus for intravenous injections and infusions in live crocodiles was evaluated. The internal diameter of the commercial human epidural catheters used during these investigations was relatively small, resulting in very slow infusion rates. Care should be taken not to puncture the spinal cord or to lacerate the blood vessel wall using this route for blood collection or intravenous infusions.

  16. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus.

    Science.gov (United States)

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E; Elkins, William; Nardone, Glenn A; Emerson, Suzanne U; Purcell, Robert H

    2007-06-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper discs from freshly killed deer. The discs were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens.

  17. [Absolute numbers of peripheral blood CD34+ hematopoietic stem cells prior to a leukapheresis procedure as a parameter predicting the efficiency of stem cell collection].

    Science.gov (United States)

    Galtseva, I V; Davydova, Yu O; Gaponova, T V; Kapranov, N M; Kuzmina, L A; Troitskaya, V V; Gribanova, E O; Kravchenko, S K; Mangasarova, Ya K; Zvonkov, E E; Parovichnikova, E N; Mendeleeva, L P; Savchenko, V G

    To identify a parameter predicting a collection of at least 2·106 CD34+ hematopoietic stem cells (HSC)/kg body weight per leukapheresis (LA) procedure. The investigation included 189 patients with hematological malignancies and 3 HSC donors, who underwent mobilization of stem cells with their subsequent collection by LA. Absolute numbers of peripheral blood leukocytes and CD34+ cells before a LA procedure, as well as a number of CD34+ cells/kg body weight (BW) in the LA product stored on the same day were determined in each patient (donor). There was no correlation between the number of leukocytes and that of stored CD34+ cells/kg BW. There was a close correlation between the count of peripheral blood CD34+ cells prior to LA and that of collected CD34+ cells calculated with reference to kg BW. The optimal absolute blood CD34+ cell count was estimated to 20 per µl, at which a LA procedure makes it possible to collect 2·106 or more CD34+ cells/kg BW.

  18. New developments in electron microscopy for serial image acquisition of neuronal profiles.

    Science.gov (United States)

    Kubota, Yoshiyuki

    2015-02-01

    Recent developments in electron microscopy largely automate the continuous acquisition of serial electron micrographs (EMGs), previously achieved by laborious manual serial ultrathin sectioning using an ultramicrotome and ultrastructural image capture process with transmission electron microscopy. The new systems cut thin sections and capture serial EMGs automatically, allowing for acquisition of large data sets in a reasonably short time. The new methods are focused ion beam/scanning electron microscopy, ultramicrotome/serial block-face scanning electron microscopy, automated tape-collection ultramicrotome/scanning electron microscopy and transmission electron microscope camera array. In this review, their positive and negative aspects are discussed. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Psychology and Psychiatry Serials: A Bibliographic Aid for Collection Development.

    Science.gov (United States)

    Persson, Dorothy M., Ed.

    1990-01-01

    This bibliography is a guide to major psychology and psychiatry periodicals evaluated by subject relevance, scholarship level, and inclusion in major indexing and abstracting tools. Citations include date first published, frequency, publisher, ISSN, where indexed and abstracted, and an annotation. Indexes by subject and publisher are included.…

  20. Mosquito blood-meal analysis for avian malaria study in wild bird communities: laboratory verification and application to Culex sasai (Diptera: Culicidae) collected in Tokyo, Japan.

    Science.gov (United States)

    Kim, Kyeong Soon; Tsuda, Yoshio; Sasaki, Toshinori; Kobayashi, Mutsuo; Hirota, Yoshikazu

    2009-10-01

    We conducted laboratory experiments to verify molecular techniques of avian malaria parasite detection distinguishing between an infected mosquito (oocysts on midgut wall) and infective mosquito (sporozoites in salivary glands) in parallel with blood-meal identification from individual blood-fed mosquitoes prior to application to field survey for avian malaria. Domestic fowl infected with Plasmodium gallinaceum was exposed to a vector and non-vector mosquito species, Aedes aegypti and Culex pipiens pallens, respectively, to compare the time course of polymerase chain reaction (PCR) detection for parasite between competent and refractory mosquitoes. DNA of the domestic fowl was detectable for at least 3 days after blood feeding. The PCR-based detection of P. gallinaceum from the abdomen and thorax of A. aegypti corresponded to the microscopic observation of oocysts and sporozoites. Therefore, this PCR-based method was considered useful as one of the criteria to assess developmental stages of Plasmodium spp. in mosquito species collected in the field. We applied the same PCR-based method to 21 blood-fed C. sasai mosquitoes collected in Rinshi-no-mori Park in urban Tokyo, Japan. Of 15 blood meals of C. sasai successfully identified, 86.7% were avian-derived, 13.3% were bovine-derived. Plasmodium DNA was amplified from the abdomen of three C. sasai specimens having an avian blood meal from the Great Tit (Parus major), Pale Thrush (Turdus pallidus), and Jungle Crow (Corvus macrorhynchos). This is the first field study on host-feeding habits of C. sasai in relation to the potential role as a vector for avian malaria parasites transmitted in the Japanese wild bird community.

  1. Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle

    International Nuclear Information System (INIS)

    Krol, M.; Lankoff, A.; Buraczewska, I.; Derezinska, E.; Wojcik, A.

    2007-01-01

    Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiosensitivity of PBL is the hormonal status of female donors, which shows a regular pattern during the menstrual cycle. The aim of the present investigation was to verify whether the position within the menstrual cycle has an impact on the level of micronuclei in PBL. Blood was collected from 19 donors during the first and second half of the menstrual cycle and exposed to 2 Gy. Although statistically significant differences between the MN frequencies in PBL collected during the different time points were observed in the case of some donors, no reproducible trend that could find application in biological dosimetry could be detected. (authors)

  2. Developmental stages of fish blood flukes, Cardicola forsteri and Cardicola opisthorchis (Trematoda: Aporocotylidae), in their polychaete intermediate hosts collected at Pacific bluefin tuna culture sites in Japan.

    Science.gov (United States)

    Ogawa, Kazuo; Shirakashi, Sho; Tani, Kazuki; Shin, Sang Phil; Ishimaru, Katsuya; Honryo, Tomoki; Sugihara, Yukitaka; Uchida, Hiro'omi

    2017-02-01

    Farming of Pacific bluefin tuna (PBT), Thunnus orientalis, is a rapidly growing industry in Japan. Aporocotylid blood flukes of the genus Cardicola comprising C. orientalis, C. opisthorchis and C. forsteri are parasites of economic importance for PBT farming. Recently, terebellid polychaetes have been identified as the intermediate hosts for all these parasites. We collected infected polychaetes, Terebella sp., the intermediate host of C. opisthorchis, from ropes and floats attached to tuna cages in Tsushima, Nagasaki Prefecture, Japan. Also, Neoamphitrite vigintipes (formerly as Amphitrite sp. sensu Shirakashi et al., 2016), the intermediate host of C. forsteri, were collected from culture cages in Kushimoto, Wakayama Prefecture, Japan. The terebellid intermediate hosts harbored the sporocysts and cercariae in their body cavity. Developmental stages of these blood flukes were molecularly identified using species specific PCR primers. In this paper, we describe the cercaria and sporocyst stages of C. opisthorchis and C. forsteri and compare their morphological characteristics among three Cardicola blood flukes infecting PBT. We also discuss phylogenetic relations of the six genera of the terebellid intermediate hosts (Artacama, Lanassa, Longicarpus, Terebella, Nicolea and Neoamphitrite) of blood flukes infecting marine fishes, based on their morphological characters. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. Technical investigation of cerebral blood flow measurements using the Patlak plot method. A contrivance for positioning of the gamma camera at data collection in radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Akihiro; Okada, Kazuhiro; Urata, Johji; Yonehara, Toshiro [Saiseikai Kumamoto Hospital (Japan); Mizuta, Yoshihiko

    1999-02-01

    The time-activity curve for the aortic arch obtained from radionuclide angiography (RNA) is handled as an input function parameter according to the method of Matsuda et al., which determines regional cerebral blood flow non-invasively. The data are collected from a frontal view of the thorax captured by RNA by their method, however we encountered a case in which it was difficult to identify aortic arch in the data collection from the frontal view. The precise identification of the aortic arch was implemented when the RNA data were collected from the left anterior oblique view of the thorax. No significant difference was noted in the measured values between the data collection from the frontal view and from the left anterior oblique view. Our method seems to be useful modification of the Patlak plot method. (author)

  4. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis.

    Science.gov (United States)

    Moonens, F; el Alami, S; Van Gossum, A; Struelens, M J; Serruys, E

    1994-01-01

    The accuracy of Gram staining of blood drawn from catheters used to administer total parenteral nutrition was compared with paired quantitative blood cultures for the diagnosis of catheter-related sepsis. Gram staining was positive in 11 of 18 episodes of catheter-related sepsis documented by quantitative culture (sensitivity, 61%) but in none of the 5 episodes of fever unrelated to catheter infection. Thus, this procedure enabled the rapid presumptive diagnosis and guidance of antimicrobial therapy for total parenteral nutrition catheter sepsis, with a positive predictive value of 100% and a negative predictive value of 42%. PMID:7521359

  5. Acceptability of study procedures (self-collected introital swabs, blood draws and stool sample collection) by students 10-16 years for an HPV vaccine effectiveness study: a pilot study.

    Science.gov (United States)

    Nakalembe, Miriam; Mutyaba, Twaha; Mirembe, Florence

    2016-03-16

    A cohort study was planned to evaluate vaccine immunogenicity and effect of malaria and helminth co-infections on the bivalent Human papilloma virus (HPV) vaccine. The study would involve self collected introital swabs, blood draws and stool sample collection. We therefore conducted a pilot study to assess the acceptability of these procedures among the students and their parents. A cross-sectional study among forty four students from two purposively selected primary schools of Western Uganda. Exit interviews and two focus group discussions (FGD) (for parents) were conducted. Acceptability was measured by willingness to undergo the procedures again, recommending the procedures to others as well as proportion of introital swabs positive for β globulin. FGD determined acceptability of the parents and explored opinions and perceptions that would influence their decisions. HPV-16/18 and β globulin deoxyribonucleic acid (DNA) were analysed using a polymerase chain reaction (PCR) kit. All the students (100%) in the study were willing to provide a self- collected introital swab and a stool sample as well as recommending their friends while (86.3%) were willing for blood draws. There were 40/44 (90.1%) self collected introital swabs that had positive result for human β globulin though none of them was positive for HPV-16/18. In the FGD, it emerged that parents concerns were on the blood draws and introital swab collection which were addressed. The study procedures were highly acceptable among this study population of students and their parents. Follow-up to assess HPV vaccine effectiveness and factors that may influence the vaccine in this age group is feasible.

  6. [The serial murder: a few theoretical perspectives].

    Science.gov (United States)

    Leistedt, S; Linkowski, P

    2011-01-01

    Despite numbers of publications and effort to try to establish the definition, the classification, the epidemiology, the clinical aspects and the psychopathology of serial killers, a universal consensus seems to say the least. Crime, though reduced in some countries, appears to impact more and more consistent worldwide, generating controversial ideas and a multitude of possible explanations. The serial killer usually presents as a caucasian man, aged between 20 and 40 years, often embedded socially and in his family, but with serious psychiatric, personal and especially family history. Usually acting alone, the serial killer plans a crime well in advance, but sometimes within the scope of impulsivity for a minority, the victim not being previously selected. In the latter case, an actual mental illness like psychosis is found. It is clear from numerous psychopathological studies conducted so far that most serial killers are defined as psychopathic sexual sadists, whose childhood was difficult, if not flouted, punctuated by physical and psychological violence situations. In addition, pervasive fantasies combined with thoughts of death, sex and violence are as much in common with the original acts of which they are the instigators. Beyond a relentless media that is constantly watering the public with stories and pictures depicting them as such, serial killers remain an enigma. We can therefore attempt to answer the various questions raised by this phenomenon, the way these people operate and how we can curb the rise, thanks to the neurobiological and neurophysiological approaches that science offers us.

  7. A Study to Develop a Methodology Determining the Feasibility of Establishing a Blood Collection Program in an Army Healthcare Facility

    Science.gov (United States)

    1985-05-01

    Cross at which time the credit is deducted. The credit system is monitored by the Camp Memoria . Blood Center. 8. Combinations of the above...witaessi Fig. 1-1. Informed consent form (sample). 1. Additional identification such as social Donor Selection’ 3 security or

  8. Serial Expression Analysis: a web tool for the analysis of serial gene expression data

    Science.gov (United States)

    Nueda, Maria José; Carbonell, José; Medina, Ignacio; Dopazo, Joaquín; Conesa, Ana

    2010-01-01

    Serial transcriptomics experiments investigate the dynamics of gene expression changes associated with a quantitative variable such as time or dosage. The statistical analysis of these data implies the study of global and gene-specific expression trends, the identification of significant serial changes, the comparison of expression profiles and the assessment of transcriptional changes in terms of cellular processes. We have created the SEA (Serial Expression Analysis) suite to provide a complete web-based resource for the analysis of serial transcriptomics data. SEA offers five different algorithms based on univariate, multivariate and functional profiling strategies framed within a user-friendly interface and a project-oriented architecture to facilitate the analysis of serial gene expression data sets from different perspectives. SEA is available at sea.bioinfo.cipf.es. PMID:20525784

  9. Collection and composition of autologous peripheral blood stem cells graft in patients with acute myeloid leukemia: influence on hematopoietic recovery and outcome.

    Science.gov (United States)

    Raos, Mirela; Nemet, Damir; Bojanić, Ines; Sertić, Dubravka; Batinić, Drago; Dusak, Vesna; Dubravcić, Klara; Mazić, Sanja; Serventi-Seiwerth, Ranka; Mrsić, Mirando; Golubić-Cepulić, Branka; Labar, Boris

    2010-03-01

    Hematopoietic stem cell (HSC) transplantation is a standard approach in the treatment of hematological malignant diseases. For the last 15 years the main source of cells for transplantation have been peripheral blood stem cells (PBSC). With the availability of hematopoietic growth factors and understanding the advantages of treatment with PBSC, the application of bone marrow (BM) was supplanted. The aim of this survey was to explore the success of PBSC collection, the factors which influence the success of PBSC collection, the composition and the quality of graft and their influence on hematopoietic recovery and outcome after transplantation in patients with acute myeloid leukemia (AML). PBSC were collected by the method of leukapheresis after applying a combination of chemotherapy and growth factors or only growth factors. The quality of graft was determined with the clonogenic progenitor cell assay and with the flow cytometry analysis. Of the total 134 patients with AML, who were submitted to HSC mobilization, the collection was successful in 78 (58.2%) patients. The collection was more successful after the first than after the second attempt of HSC mobilization (49% vs. 11%). The criteria for effective mobilization were the number of leukocytes > 3 x 10(9)/L and the concentration of CD34+ cells > 20 x 10(3)/mL in the peripheral blood on the first day of leukapheresis. The number of CD34+ cells infused had the strongest impact on hematopoietic recovery. We noted significantly faster hematological recovery of neutrophils and platelets, fewer number of transfused units of red blood cells and platelets, shorter duration of the tranfusion support, shorter treatment with intravenous antibiotic therapy and shorter hospitalization after PBSC compared to BM transplantation. These advantages could provide their standard application in the treatment of patients with AML.

  10. Stochastic modeling of a serial killer.

    Science.gov (United States)

    Simkin, M V; Roychowdhury, V P

    2014-08-21

    We analyze the time pattern of the activity of a serial killer, who during 12 years had murdered 53 people. The plot of the cumulative number of murders as a function of time is of "Devil's staircase" type. The distribution of the intervals between murders (step length) follows a power law with the exponent of 1.4. We propose a model according to which the serial killer commits murders when neuronal excitation in his brain exceeds certain threshold. We model this neural activity as a branching process, which in turn is approximated by a random walk. As the distribution of the random walk return times is a power law with the exponent 1.5, the distribution of the inter-murder intervals is thus explained. We illustrate analytical results by numerical simulation. Time pattern activity data from two other serial killers further substantiate our analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Converting serial networks to Ethernet communications

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Elroy [Freewave Technologies, Inc., Boulder, CO (United States). Latin America

    2008-07-01

    Many oil and gas producers and pipeline companies find themselves in an awkward position. They have invested millions of dollars in legacy serial communications systems and in most cases, millions more in older SCADA remote terminal units and electronic flow meters. There is a desire throughout most of the industry to convert these systems to Ethernet. This presentation will explore how Ethernet protocol offers advantages over the older serial communications in terms of peer to peer communication, faster polling cycles, and the ability to poll multiple devices at the same time. (author)

  12. Multistage parallel-serial time averaging filters

    International Nuclear Information System (INIS)

    Theodosiou, G.E.

    1980-01-01

    Here, a new time averaging circuit design, the 'parallel filter' is presented, which can reduce the time jitter, introduced in time measurements using counters of large dimensions. This parallel filter could be considered as a single stage unit circuit which can be repeated an arbitrary number of times in series, thus providing a parallel-serial filter type as a result. The main advantages of such a filter over a serial one are much less electronic gate jitter and time delay for the same amount of total time uncertainty reduction. (orig.)

  13. Serial position effects in mild cognitive impairment.

    Science.gov (United States)

    Howieson, Diane B; Mattek, Nora; Seeyle, Adriana M; Dodge, Hiroko H; Wasserman, Dara; Zitzelberger, Tracy; Jeffrey, Kaye

    2011-03-01

    Mild cognitive impairment (MCI) is often associated with the preclinical phase of Alzheimer's disease (AD). Special scoring of word-list recall data for serial position has been suggested to improve discrimination of normal aging from dementia. We examined serial position effects in word-list recall for MCI participants compared to Alzheimer patients and controls. Individuals with MCI, like Alzheimer patients, had a diminished primacy effect in recalling words from a list. No alternative scoring system was better than standard scoring of word-list recall in distinguishing MCI patients from controls. Retention weighted scoring improved the discrimination of MCI and AD groups.

  14. The eyeball killer: serial killings with postmortem globe enucleation.

    Science.gov (United States)

    Coyle, Julie; Ross, Karen F; Barnard, Jeffrey J; Peacock, Elizabeth; Linch, Charles A; Prahlow, Joseph A

    2015-05-01

    Although serial killings are relatively rare, they can be the cause of a great deal of anxiety while the killer remains at-large. Despite the fact that the motivations for serial killings are typically quite complex, the psychological analysis of a serial killer can provide valuable insight into how and why certain individuals become serial killers. Such knowledge may be instrumental in preventing future serial killings or in solving ongoing cases. In certain serial killings, the various incidents have a variety of similar features. Identification of similarities between separate homicidal incidents is necessary to recognize that a serial killer may be actively killing. In this report, the authors present a group of serial killings involving three prostitutes who were shot to death over a 3-month period. Scene and autopsy findings, including the unusual finding of postmortem enucleation of the eyes, led investigators to recognize the serial nature of the homicides. © 2015 American Academy of Forensic Sciences.

  15. The effects of serial intravascular transfusions in ascitic/hydropic RhD-alloimmunized fetuses.

    Science.gov (United States)

    Craparo, F J; Bonati, F; Gementi, P; Nicolini, U

    2005-02-01

    To evaluate the effects of serial intravascular transfusions on RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion by measuring multiple hematological/biochemical blood variables. Thirty-one singleton pregnancies were referred for management of RhD alloimmunization. Seven fetuses had hydrops on presentation and were transfused immediately. The remainder underwent weekly ultrasound examinations, and fetal blood sampling and transfusion were performed on development of ascites. In the 104 samples collected overall from the 31 fetuses, glucose, uric acid, urea, creatinine, total protein, total and direct bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyltransferase, alkaline phosphatase, lactic dehydrogenase, amylase, pseudocholinesterase (PCHE), creatine kinase, triglycerides and cholesterol were measured and compared with a reference range for non-anemic fetuses. The median gestational age at first transfusion was 26 (range, 18-34) weeks. There were three fetal losses after the first transfusion, two of which were due to procedure-related complications; one further loss occurred. At the first transfusion fetal hematocrit, pO2, total protein, PCHE, creatinine and urea concentrations were significantly decreased compared to reference data, while total and direct bilirubin, AST, ALT, amylase, triglyceride and uric acid concentrations were increased. In all surviving fetuses ascites/hydrops had disappeared by the second transfusion. Fetal pO2, total protein, AST, ALT and PCHE concentrations had normalized by the third transfusion. Correction of fetal anemia did not affect the other variables. RhD-alloimmunized fetuses with ascites/hydrops at the time of the first transfusion had a survival rate of 87%. Alterations of several biochemical fetal blood indices are present at the first sampling/transfusion, but most variables normalize with intravascular transfusions. Copyright 2005 ISUOG.

  16. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  17. Recalling visual serial order for verbal sequences

    NARCIS (Netherlands)

    Logie, R.H.; Saito, S.; Morita, A.; Varma, S.; Norris, D.

    2016-01-01

    We report three experiments in which participants performed written serial recall of visually presented verbal sequences with items varying in visual similarity. In Experiments 1 and 2 native speakers of Japanese recalled visually presented Japanese Kanji characters. In Experiment 3, native speakers

  18. Serial analysis of gene expression (SAGE)

    NARCIS (Netherlands)

    van Ruissen, Fred; Baas, Frank

    2007-01-01

    In 1995, serial analysis of gene expression (SAGE) was developed as a versatile tool for gene expression studies. SAGE technology does not require pre-existing knowledge of the genome that is being examined and therefore SAGE can be applied to many different model systems. In this chapter, the SAGE

  19. Facial rejuvenation: Serial fat graft transfer

    African Journals Online (AJOL)

    Saad Mohamed Saad Ibrahiem

    2016-02-01

    Feb 1, 2016 ... This a clinical study carried out to test the aesthetic outcome of serial injection of the cryo-preserved fat cells for both aesthetic and reconstructive purposes. Methods: Clinical ..... ucts, devices, or drugs mentioned in this manuscript that might create a ... Adipose stem cells and regenerative medicine. 7th ed.

  20. Advances in Serials Management. Volume 6.

    Science.gov (United States)

    Hepfer, Cindy, Ed.; Gammon, Julia, Ed.; Malinowski, Teresa, Ed.

    In order to further discussion and support constructive change, this volume presents the following eight papers on various dimensions of serials management: (1) "CD-ROMs, Surveys, and Sales: The OSA [Optical Society of America] Experience" (Frank E. Harris and Alan Tourtlotte); (2) "Management and Integration of Electronic Journals into the…

  1. In vivo serial sampling of epididymal sperm in mice.

    Science.gov (United States)

    Del Val, Gonzalo Moreno; Robledano, Patricia Muñoz

    2013-07-01

    This study was undertaken to refine the techniques of in vivo collection of sperm in the mouse. The principal objective was to offer a viable, safe and reliable method for serial collection of in vivo epididimary sperm through the direct puncture of the epididymis. Six C57Bl/6J males were subjected to the whole experiment. First we obtain a sperm sample of the right epididymis, and perform a vasectomy on the left side. This sample was used in an in vitro fertilization (IVF) experiment while the males were individually housed for 10 days to let them recover from the surgery, and then their fertility was tested with natural matings until we obtained a litter of each one. After that, the animals were subjected another time to the same process (sampling, recover and natural mating). The results of these experiments were a fertilization average value of 56.7%, and that all the males had a litter in the first month after the natural matings. This study documented the feasibility of the epididimary puncture technique to in vivo serial sampling of sperm in the mouse.

  2. Comparison of manual methods of extracting genomic DNA from dried blood spots collected on different cards: implications for clinical practice.

    Science.gov (United States)

    Molteni, C G; Terranova, L; Zampiero, A; Galeone, C; Principi, N; Esposito, S

    2013-01-01

    Isolating genomic DNA from blood samples is essential when studying the associations between genetic variants and susceptibility to a given clinical condition, or its severity. This study of three extraction techniques and two types of commercially available cards involved 219 children attending our outpatient pediatric clinic for follow-up laboratory tests after they had been hospitalised. An aliquot of venous blood was drawn into plastic tubes without additives and, after several inversions, 80 microL were put on circles of common paper cards and Whatman FTA-treated cards. Three extraction methods were compared: the Qiagen Investigator, Gensolve, and Masterpure. The best method in terms of final DNA yield was Masterpure, which led to a significantly higher yield regardless of the type of card (p less than 0.001), followed by Qiagen Investigator and Gensolve. Masterpure was also the best in terms of price, seemed to be simple and reliable, and required less hands-on time than other techniques. These conclusions support the use of Masterpure in studies that evaluate the associations between genetic variants and the severity or prevalence of infectious diseases.

  3. Diagnostic Value of Serial Measurement of C-Reactive Protein in the Detection of a Surgical Complication after Laparoscopic Bowel Resection for Endometriosis

    DEFF Research Database (Denmark)

    Riiskjær, Mads; Forman, Axel; Kesmodel, Ulrik Schiøler

    2016-01-01

    AIMS: The study aimed to assess the diagnostic value of serial monitoring of biochemical inflammatory markers (C-reactive protein (CRP) and white blood cell (WBC) count) in the postoperative diagnosis of anastomotic leakage or ureteral injury after bowel resection for deep infiltrating endometrio......AIMS: The study aimed to assess the diagnostic value of serial monitoring of biochemical inflammatory markers (C-reactive protein (CRP) and white blood cell (WBC) count) in the postoperative diagnosis of anastomotic leakage or ureteral injury after bowel resection for deep infiltrating...... endometriosis. METHODS: This is a review of prospectively collected data from 217 patients who underwent laparoscopic bowel resection for endometriosis from January 2009 to April 2015. Patients with an anastomotic leakage or ureteral injury were identified and classified. RESULTS: The frequency of anastomotic...... leakage requiring reoperation was 8.3%. The frequency of ureteral injury was 4.6%. Median time to diagnosis was 6 days for anastomotic leakage and 8 days for ureteral injury. The daily mean values of serum CRP were significantly higher in patients with a surgical complication starting at the second...

  4. Determination of motive of serial invaders as a stage of serial murders investigation

    Directory of Open Access Journals (Sweden)

    Davydov A.B.

    2017-04-01

    Full Text Available the article discusses the existing classification of motives of serial murderers. The author provides the classification, which is based on the technique of extreme meanings offered by D.A. Leontyev.

  5. Serial position markers in space: visuospatial priming of serial order working memory retrieval.

    Directory of Open Access Journals (Sweden)

    Maya De Belder

    Full Text Available Most general theories on serial order working memory (WM assume the existence of position markers that are bound to the to-be-remembered items to keep track of the serial order. So far, the exact cognitive/neural characteristics of these markers have remained largely underspecified, while direct empirical evidence for their existence is mostly lacking. In the current study we demonstrate that retrieval from verbal serial order WM can be facilitated or hindered by spatial cuing: begin elements of a verbal WM sequence are retrieved faster after cuing the left side of space, while end elements are retrieved faster after cuing the right side of space. In direct complement to our previous work--where we showed the reversed impact of WM retrieval on spatial processing--we argue that the current findings provide us with a crucial piece of evidence suggesting a direct and functional involvement of space in verbal serial order WM. We outline the idea that serial order in verbal WM is coded within a spatial coordinate system with spatial attention being involved when searching through WM, and we discuss how this account can explain several hallmark observations related to serial order WM.

  6. Temporal stability of blood lead concentrations in adults exposed only to environmental lead

    Energy Technology Data Exchange (ETDEWEB)

    Delves, H T; Sherlock, J C; Quinn, M J

    1984-08-01

    The temporal stability of blood lead concentrations of 21 health adults (14 men and 7 women) exposed only to environmental lead was assessed by analysis of 253 blood specimens collected serially over periods from 7 to 11 months. The women had lower blood lead concentrations (mean 8.5, range 7.4-10.8 micrograms/100 ml) than did the men (mean 12.2, range 8.6-15.8 micrograms/100 ml). These are within the expected ranges for non-occupationally exposed persons. Blood lead concentrations in the serial specimens from both men and women changed very little over the study period, with standard deviations of less than 0.5 micrograms/100 ml for the majority of individual mean concentrations: for all except low subjects the standard deviations were less than 0.8 micrograms/100 ml. Two subjects showed significant changes in blood lead concentrations during the study. A temporary increase in oral lead intake was identified for one of these subjects. In the absence of substantial changes in lead exposure blood lead levels in adults are remarkably stable and for their environmental monitoring a single blood lead concentration is an excellent biological indicator.

  7. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... resource to help stay current with the latest advances in the field Hematology 2017 A collection of articles ... Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ...

  8. Susceptibility to antifungal agents of Candida spp. from blood and feces collected in Novi Sad in 3-year period (2008-2010

    Directory of Open Access Journals (Sweden)

    Jelesić Zora Z.

    2011-01-01

    Full Text Available Candidemia is an important emerging nosocomial infection in patients with risk factors. Candida species from nonsterile sites can give insight into the characteristics of strains that may cause invasive disease. The aim of this study was to evaluate antifungal susceptibility of Candida blood and fecal isolates in Novi Sad, Vojvodina. During a 3-year period (2008 to 2010, 424 isolates of Candida spp. were collected, 30 bloodstream isolates and 394 strains from fecal samples. In vitro susceptibility of these isolates to five antifungal agents was established using commercial ATB FUNGUS 3 (Bio-Mérieux. Predominant species was Candida albicans (6 isolates from blood and 269 from feces. Resistance to one or more antifungal agents was less common in Candida albicans (3.63% than in other species (24.83%. Resistance to itraconazole was the most commonly found in both groups of isolates, 9.64% strains from feces and 20% from blood samples. Twelve isolates were multiply resistant, usually to fluconazole, itraconazole, and voriconazole. Resistance to amphotericine B was extremely rare. Although resistance to antimycotics of Candida spp. is rare at present, continued surveillance of antifungal susceptibility is necessary in order to monitor trends, and to choose the right empiric therapy.

  9. A Look at Librarianship through the Lens of an Academic Library Serials Review

    Directory of Open Access Journals (Sweden)

    Annette Day

    2009-07-01

    Full Text Available Talk to any librarian or library vendor and you’ll hear the same thing – the global economic downturn is hitting hard. Libraries everywhere are taking an axe to their collections; libraries are cutting book budgets, canceling serials subscriptions, allowing institutional memberships to lapse, and letting go of databases. Libraries and their stakeholders are having to [...

  10. Automated blood-sample handling in the clinical laboratory.

    Science.gov (United States)

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  11. Determine the prevalence of Brucella spp. and Leptospira spp. in blood samples by multiplex polymerase chain reaction collected from cattle, sheep and goats in herds located in provinces of Iran

    OpenAIRE

    Faham Khamesipour; Shahin Nejat Dehkordi; Taghi Taktaz Hafshejani; Elahe Tajbakhsh; Shahrzad Azizi

    2014-01-01

    Leptospirosis and brucellosis are common zoonosis that affect many species of mammals mostly causing economical losses. Further, very important fact is huge danger for human and animal health around the world. The purpose of the study is to determine the prevalence of Brucella spp. and Leptospira spp. using multiplex polymerase chain reaction (mPCR) method, in blood samples collected from cattle, sheep and goats. In this study, a total number of 250 blood samples (5 cc of blood with ethilen d...

  12. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

    Science.gov (United States)

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth

    2018-02-15

    Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.

  13. [Blood cultures in the paediatric emergency department. Guidelines and recommendations on their indications, collection, processing and interpretation].

    Science.gov (United States)

    Hernández-Bou, S; Álvarez Álvarez, C; Campo Fernández, M N; García Herrero, M A; Gené Giralt, A; Giménez Pérez, M; Piñeiro Pérez, R; Gómez Cortés, B; Velasco, R; Menasalvas Ruiz, A I; García García, J J; Rodrigo Gonzalo de Liria, C

    2016-05-01

    Blood culture (BC) is the gold standard when a bacteraemia is suspected, and is one of the most requested microbiological tests in paediatrics. Some changes have occurred in recent years: the introduction of new vaccines, the increasing number of patients with central vascular catheters, as well as the introduction of continuous monitoring BC systems. These changes have led to the review and update of different factors related to this technique in order to optimise its use. A practice guideline is presented with recommendations on BC, established by the Spanish Society of Paediatric Emergency Care and the Spanish Society for Paediatric Infectious Diseases. After reviewing the available scientific evidence, several recommendations for each of the following aspects are presented: BC indications in the Emergency Department, how to obtain, transport and process cultures, special situations (indications and interpretation of results in immunosuppressed patients and/or central vascular catheter carriers, indications for anaerobic BC), differentiation between bacteraemia and contamination when a BC shows bacterial growth and actions to take with a positive BC in patients with fever of unknown origin. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  14. [Measures to prevent patient identification errors in blood collection/physiological function testing utilizing a laboratory information system].

    Science.gov (United States)

    Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji

    2013-08-01

    We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.

  15. An Investigation of Selective College and University Libraries' Serial Arrangement.

    Science.gov (United States)

    Kesler, Elizabeth Gates; Teborek, Gay

    Data from a survey on serials arrangement procedures and policies at academic libraries was used by the University of Rhode Island (URI) Library in changing current serials policies. Ten libraries, four of which have similar serial holdings and user populations to URI, responded to a questionnaire. Information was obtained on classification versus…

  16. Sensing the Opaque : Seriality and the Aesthetics of Televisual Form

    NARCIS (Netherlands)

    Dasgupta, S.; Kelleter, F.

    2017-01-01

    Recent work on TV seriality focuses on the deference of meaning through narrative extension. Contemporary seriality, it has been argued, exploits this expanding textuality to construct complicated narratives that tip the pleasures of seriality toward detecting the meaning of the plot's

  17. Serial Millisecond Crystallography of Membrane Proteins.

    Science.gov (United States)

    Jaeger, Kathrin; Dworkowski, Florian; Nogly, Przemyslaw; Milne, Christopher; Wang, Meitian; Standfuss, Joerg

    2016-01-01

    Serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) is a powerful method to determine high-resolution structures of pharmaceutically relevant membrane proteins. Recently, the technology has been adapted to carry out serial millisecond crystallography (SMX) at synchrotron sources, where beamtime is more abundant. In an injector-based approach, crystals grown in lipidic cubic phase (LCP) or embedded in viscous medium are delivered directly into the unattenuated beam of a microfocus beamline. Pilot experiments show the application of microjet-based SMX for solving the structure of a membrane protein and compatibility of the method with de novo phasing. Planned synchrotron upgrades, faster detectors and software developments will go hand-in-hand with developments at free-electron lasers to provide a powerful methodology for solving structures from microcrystals at room temperature, ligand screening or crystal optimization for time-resolved studies with minimal or no radiation damage.

  18. [Personality disorders, psychopathy and serial killers].

    Science.gov (United States)

    Morana, Hilda C P; Stone, Michael H; Abdalla-Filho, Elias

    2006-10-01

    To illustrate the basic characteristics of several specific personality disorders, focusing mainly in antisocial personality disorder. The differences between antisocial personality disorder and psychopathy are highlighted. Serial killers and its psychopathic aspects are also discussed. A bibliographic review was completed in order to outline convergences and divergences among different authors about this controversial issue, especially those concerning the possibility of treatment. While anti-social personality disorder is a medical diagnosis, the term "psychopathy" (which belongs to the sphere of forensic psychiatry) may be understood as a "legal diagnosis". It is not still possible to identify an effective treatment for serial killers. Personality disorders, especially of the antisocial type, still represent a formidable challenge to forensic psychiatry today. Questions as yet unanswered include the best and most humane place for patients with this condition and the nature of a standardised treatment recommendation.

  19. Oscillating in synchrony with a metronome: serial dependence, limit cycle dynamics, and modeling.

    Science.gov (United States)

    Torre, Kjerstin; Balasubramaniam, Ramesh; Delignières, Didier

    2010-07-01

    We analyzed serial dependencies in periods and asynchronies collected during oscillations performed in synchrony with a metronome. Results showed that asynchronies contain 1/f fluctuations, and the series of periods contain antipersistent dependence. The analysis of the phase portrait revealed a specific asymmetry induced by synchronization. We propose a hybrid limit cycle model including a cycle-dependent stiffness parameter provided with fractal properties, and a parametric driving function based on velocity. This model accounts for most experimentally evidenced statistical features, including serial dependence and limit cycle dynamics. We discuss the results and modeling choices within the framework of event-based and emergent timing.

  20. Non-invasive fetal RHD genotyping for RhD negative women stratified into RHD gene deletion or variant groups: comparative accuracy using two blood collection tube types.

    Science.gov (United States)

    Hyland, Catherine A; Millard, Glenda M; O'Brien, Helen; Schoeman, Elizna M; Lopez, Genghis H; McGowan, Eunike C; Tremellen, Anne; Puddephatt, Rachel; Gaerty, Kirsten; Flower, Robert L; Hyett, Jonathan A; Gardener, Glenn J

    2017-12-01

    Non-invasive fetal RHD genotyping in Australia to reduce anti-D usage will need to accommodate both prolonged sample transport times and a diverse population demographic harbouring a range of RHD blood group gene variants. We compared RHD genotyping accuracy using two blood sample collection tube types for RhD negative women stratified into deleted RHD gene haplotype and RHD gene variant cohorts. Maternal blood samples were collected into EDTA and cell-free (cf)DNA stabilising (BCT) tubes from two sites, one interstate. Automated DNA extraction and polymerase chain reaction (PCR) were used to amplify RHD exons 5 and 10 and CCR5. Automated analysis flagged maternal RHD variants, which were classified by genotyping. Time between sample collection and processing ranged from 2.9 to 187.5 hours. cfDNA levels increased with time for EDTA (range 0.03-138 ng/μL) but not BCT samples (0.01-3.24 ng/μL). For the 'deleted' cohort (n=647) all fetal RHD genotyping outcomes were concordant, excepting for one unexplained false negative EDTA sample. Matched against cord RhD serology, negative predictive values using BCT and EDTA tubes were 100% and 99.6%, respectively. Positive predictive values were 99.7% for both types. Overall 37.2% of subjects carried an RhD negative baby. The 'variant' cohort (n=15) included one novel RHD and eight hybrid or African pseudogene variants. Review for fetal RHD specific signals, based on one exon, showed three EDTA samples discordant to BCT, attributed to high maternal cfDNA levels arising from prolonged transport times. For the deleted haplotype cohort, fetal RHD genotyping accuracy was comparable for samples collected in EDTA and BCT tubes despite higher cfDNA levels in the EDTA tubes. Capacity to predict fetal RHD genotype for maternal carriers of hybrid or pseudogene RHD variants requires stringent control of cfDNA levels. We conclude that fetal RHD genotyping is feasible in the Australian environment to avoid unnecessary anti

  1. Working memory capacity and controlled serial memory search.

    Science.gov (United States)

    Mızrak, Eda; Öztekin, Ilke

    2016-08-01

    The speed-accuracy trade-off (SAT) procedure was used to investigate the relationship between working memory capacity (WMC) and the dynamics of temporal order memory retrieval. High- and low-span participants (HSs, LSs) studied sequentially presented five-item lists, followed by two probes from the study list. Participants indicated the more recent probe. Overall, accuracy was higher for HSs compared to LSs. Crucially, in contrast to previous investigations that observed no impact of WMC on speed of access to item information in memory (e.g., Öztekin & McElree, 2010), recovery of temporal order memory was slower for LSs. While accessing an item's representation in memory can be direct, recovery of relational information such as temporal order information requires a more controlled serial memory search. Collectively, these data indicate that WMC effects are particularly prominent during high demands of cognitive control, such as serial search operations necessary to access temporal order information from memory. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Comparison of Ahlstrom grade 226, Munktell TFN, and Whatman 903 filter papers for dried blood spot specimen collection and subsequent HIV-1 load and drug resistance genotyping analysis.

    Science.gov (United States)

    Rottinghaus, Erin; Bile, Ebi; Modukanele, Mosetsanagape; Maruping, Maruping; Mine, Madisa; Nkengasong, John; Yang, Chunfu

    2013-01-01

    Dried blood spots (DBS) collected onto filter paper have eased the difficulty of blood collection in resource-limited settings. Currently, Whatman 903 (W-903) filter paper is the only filter paper that has been used for HIV load and HIV drug resistance (HIVDR) testing. We therefore evaluated two additional commercially available filter papers, Ahlstrom grade 226 (A-226) and Munktell TFN (M-TFN), for viral load (VL) testing and HIVDR genotyping using W-903 filter paper as a comparison group. DBS specimens were generated from 344 adult patients on antiretroviral therapy (ART) in Botswana. The VL was measured with NucliSENS EasyQ HIV-1 v2.0, and genotyping was performed for those specimens with a detectable VL (≥ 2.90 log(10) copies/ml) using an in-house method. Bland-Altman analysis revealed a strong concordance in quantitative VL analysis between W-903 and A-226 (bias = -0.034 ± 0.246 log(10) copies/ml [mean difference ± standard deviation]) and W-903 and M-TFN (bias = -0.028 ± 0.186 log(10) copies/ml) filter papers, while qualitative VL analysis for virological failure determination, defined as a VL of ≥ 3.00 log(10) copies/ml, showed low sensitivities for A-266 (71.54%) and M-TFN (65.71%) filter papers compared to W-903 filter paper. DBS collected on M-TFN filter paper had the highest genotyping efficiency (100%) compared to W-903 and A-226 filter papers (91.7%) and appeared more sensitive in detecting major HIVDR mutations. DBS collected on A-226 and M-TFN filter papers performed similarly to DBS collected on W-903 filter paper for quantitative VL analysis and HIVDR detection. Together, the encouraging genotyping results and the variability observed in determining virological failure from this small pilot study warrant further investigation of A-226 and M-TFN filter papers as specimen collection devices for HIVDR monitoring surveys.

  3. Fungal myositis in children: serial ultrasonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jung Hwa; Lee, Hee Jung; Choi, Jin Soo [Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2003-08-01

    To evaluate serial ultrasonographic findings of fungal myositis in children. Eleven lesions caused by fungal myositis and occurring in six children were included in this study. Eight lesions in five children were histopathologically proven and the other three were clinically diagnosed. Serial ultrasonographic findings were retrospectively evaluated in terms of size, location, margin, internal echotexture and adjacent cortical change occurring during the follow-up period ranging from five days to two months. Three patients (50%) had multiple lesions. The sites of involvment were the thigh (n=4), calf (n=3), chest wall (n=2), abdominal wall (n=1) and forearm (n=1). Initially, diffuse muscular swelling was revealed, with ill-defined hypoechoic lesions confined to the muscle layer (n=8). Follow-up examination of eight lesions over a period of 5-10 days showed that round central echogenic lesions were surrounded by previous slightly echogenic lesions (n=6, 75%). Long-term follow-up of five lesions over a two-month period revealed periosteal thickening in one case (20%), and the peristence of echogenic solid nodules in four (80%). Pathologic examination showed that the central lesions correlated with a fungus ball and the peripheral slightly echogenic lesions corresponded to hematoma and necrosis. Serial ultrasonographic findings of fungal myositis in children revealed relatively constant features in each case. In particular, the findings of muscular necrosis and a fungus ball over a period of 5-14 days were thought to be characteristic.

  4. Fungal myositis in children: serial ultrasonographic findings

    International Nuclear Information System (INIS)

    Kwon, Jung Hwa; Lee, Hee Jung; Choi, Jin Soo

    2003-01-01

    To evaluate serial ultrasonographic findings of fungal myositis in children. Eleven lesions caused by fungal myositis and occurring in six children were included in this study. Eight lesions in five children were histopathologically proven and the other three were clinically diagnosed. Serial ultrasonographic findings were retrospectively evaluated in terms of size, location, margin, internal echotexture and adjacent cortical change occurring during the follow-up period ranging from five days to two months. Three patients (50%) had multiple lesions. The sites of involvment were the thigh (n=4), calf (n=3), chest wall (n=2), abdominal wall (n=1) and forearm (n=1). Initially, diffuse muscular swelling was revealed, with ill-defined hypoechoic lesions confined to the muscle layer (n=8). Follow-up examination of eight lesions over a period of 5-10 days showed that round central echogenic lesions were surrounded by previous slightly echogenic lesions (n=6, 75%). Long-term follow-up of five lesions over a two-month period revealed periosteal thickening in one case (20%), and the peristence of echogenic solid nodules in four (80%). Pathologic examination showed that the central lesions correlated with a fungus ball and the peripheral slightly echogenic lesions corresponded to hematoma and necrosis. Serial ultrasonographic findings of fungal myositis in children revealed relatively constant features in each case. In particular, the findings of muscular necrosis and a fungus ball over a period of 5-14 days were thought to be characteristic

  5. Perfluorooctane sulfonate (PFOS) and other fluorochemicals in fish blood collected near the outfall of wastewater treatment plant (WWTP) in Beijing

    International Nuclear Information System (INIS)

    Li Xuemei; Yeung, Leo Wai Yin; Xu Muqi; Taniyasu, Sachi; Lam, Paul K.S.; Yamashita, Nobuyoshi; Dai Jiayin

    2008-01-01

    Perfluorinated compounds (PFCs) were measured in zooplankton and five fish species collected from Gaobeidian Lake, which receives discharge from wastewater treatment plant (WWTP) in Beijing, China. The mean total PFCs in five fish were in the order: crucian carp > common carp > leather catfish > white semiknife carp > tilapia. Perfluorooctane sulfonate (PFOS) occurred at the greatest concentrations, with mean concentrations ranging from 5.74 to 64.2 ng/ml serum. Perfluorodecanoic acid (PFDA) was the second dominant PFC in fish samples except for common carp in which perfluorooctane sulfonamide (PFOSA) was dominant. A positive linear relationship (r 2 = 0.85, p 15 N) if tilapia was excluded. The risk assessment showed that PFOS might not pose an immediate risk to fish in Gaobeidian Lake. - Distribution of PFCs reveals varied composition profiles in zooplankton and fish from a recipient water affected by WWTPs in Beijing

  6. Cord Blood

    Directory of Open Access Journals (Sweden)

    Saeed Abroun

    2014-05-01

    Full Text Available   Stem cells are naïve or master cells. This means they can transform into special 200 cell types as needed by body, and each of these cells has just one function. Stem cells are found in many parts of the human body, although some sources have richer concentrations than others. Some excellent sources of stem cells, such as bone marrow, peripheral blood, cord blood, other tissue stem cells and human embryos, which last one are controversial and their use can be illegal in some countries. Cord blood is a sample of blood taken from a newborn baby's umbilical cord. It is a rich source of stem cells, umbilical cord blood and tissue are collected from material that normally has no use following a child’s birth. Umbilical cord blood and tissue cells are rich sources of stem cells, which have been used in the treatment of over 80 diseases including leukemia, lymphoma and anemia as bone marrow stem cell potency.  The most common disease category has been leukemia. The next largest group is inherited diseases. Patients with lymphoma, myelodysplasia and severe aplastic anemia have also been successfully transplanted with cord blood. Cord blood is obtained by syringing out the placenta through the umbilical cord at the time of childbirth, after the cord has been detached from the newborn. Collecting stem cells from umbilical blood and tissue is ethical, pain-free, safe and simple. When they are needed to treat your child later in life, there will be no rejection or incompatibility issues, as the procedure will be using their own cells. In contrast, stem cells from donors do have these potential problems. By consider about cord blood potency, cord blood banks (familial or public were established. In IRAN, four cord blood banks has activity, Shariati BMT center cord blood bank, Royan familial cord blood banks, Royan public cord blood banks and Iranian Blood Transfusion Organ cord blood banks. Despite 50,000 sample which storage in these banks, but the

  7. Serial High-Sensitivity Troponin T in Post-Primary Angioplasty Exercise Test

    Directory of Open Access Journals (Sweden)

    Humberto Andres Vaz

    2016-04-01

    Full Text Available Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET, and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h, 2 (TnT2h, 5 (TnT5h, and 8 hours (TnT8h after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance. Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h. After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002, 59% (p = 0.003 and 45% (p = 0.003 higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

  8. Serial High-Sensitivity Troponin T in Post-Primary Angioplasty Exercise Test

    Energy Technology Data Exchange (ETDEWEB)

    Vaz, Humberto Andres, E-mail: humbertovaz@cardiol.br; Vanz, Ana Paula; Castro, Iran [Instituto de Cardiologia - Fundação Universitária de Cardiologia, Porto Alegre, RS (Brazil)

    2016-04-15

    The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT{sub 0h}), 2 (TnT{sub 2h}), 5 (TnT{sub 5h}), and 8 hours (TnT{sub 8h}) after ET. The outcomes were peak hscTnT, TnT{sub 5h}/TnT{sub 0h} ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT{sub 0h}, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). This study included 95 patients. The highest geometric means were observed at 5 hours (TnT{sub 5h}). After adjustments, peak hscTnT, TnT{sub 5h}/TnT{sub 0h} and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

  9. From animal cruelty to serial murder: applying the graduation hypothesis.

    Science.gov (United States)

    Wright, Jeremy; Hensley, Christopher

    2003-02-01

    Although serial murder has been recorded for centuries, limited academic attention has been given to this important topic. Scholars have attempted to examine the causality and motivations behind the rare phenomenon of serial murder. However, scant research exists which delves into the childhood characteristics of serial murderers. Using social learning theory, some of these studies present supporting evidence for a link between childhood animal cruelty and adult aggression toward humans. Based on five case studies of serial murderers, we contribute to the existing literature by exploring the possible link between childhood cruelty toward animals and serial murder with the application of the graduation hypothesis.

  10. Perfluorooctane sulfonate (PFOS) and other fluorochemicals in fish blood collected near the outfall of wastewater treatment plant (WWTP) in Beijing

    Energy Technology Data Exchange (ETDEWEB)

    Li Xuemei [Key Laboratory of Animal Ecology and Conservation Biology, Institute of Zoology, Chinese Academy of Sciences, Datun Road, Chaoyang District, Beijing 100101 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Yeung, Leo Wai Yin [Department of Biology and Chemistry, City University of Hong Kong (China); National Institute of Advanced Industrial Science and Technology, 16-1 Onogawa, Tsukuba, Ibaraki 305-8569 (Japan); Xu Muqi [Key Laboratory of Animal Ecology and Conservation Biology, Institute of Zoology, Chinese Academy of Sciences, Datun Road, Chaoyang District, Beijing 100101 (China); Taniyasu, Sachi [National Institute of Advanced Industrial Science and Technology, 16-1 Onogawa, Tsukuba, Ibaraki 305-8569 (Japan); Lam, Paul K.S. [Department of Biology and Chemistry, City University of Hong Kong (China); Yamashita, Nobuyoshi [National Institute of Advanced Industrial Science and Technology, 16-1 Onogawa, Tsukuba, Ibaraki 305-8569 (Japan)], E-mail: nob.yamashita@aist.go.jp; Dai Jiayin [Key Laboratory of Animal Ecology and Conservation Biology, Institute of Zoology, Chinese Academy of Sciences, Datun Road, Chaoyang District, Beijing 100101 (China)], E-mail: daijy@ioz.ac.cn

    2008-12-15

    Perfluorinated compounds (PFCs) were measured in zooplankton and five fish species collected from Gaobeidian Lake, which receives discharge from wastewater treatment plant (WWTP) in Beijing, China. The mean total PFCs in five fish were in the order: crucian carp > common carp > leather catfish > white semiknife carp > tilapia. Perfluorooctane sulfonate (PFOS) occurred at the greatest concentrations, with mean concentrations ranging from 5.74 to 64.2 ng/ml serum. Perfluorodecanoic acid (PFDA) was the second dominant PFC in fish samples except for common carp in which perfluorooctane sulfonamide (PFOSA) was dominant. A positive linear relationship (r{sup 2} = 0.85, p < 0.05) was observed between ln PFOS concentrations (ln ng/ml) and trophic level (based on {delta}{sup 15}N) if tilapia was excluded. The risk assessment showed that PFOS might not pose an immediate risk to fish in Gaobeidian Lake. - Distribution of PFCs reveals varied composition profiles in zooplankton and fish from a recipient water affected by WWTPs in Beijing.

  11. Application of the CometChip platform to assess DNA damage in field-collected blood samples from turtles.

    Science.gov (United States)

    Sykora, Peter; Chiari, Ylenia; Heaton, Andrew; Moreno, Nickolas; Glaberman, Scott; Sobol, Robert W

    2018-05-01

    DNA damage has been linked to genomic instability and the progressive breakdown of cellular and organismal homeostasis, leading to the onset of disease and reduced longevity. Insults to DNA from endogenous sources include base deamination, base hydrolysis, base alkylation, and metabolism-induced oxidative damage that can lead to single-strand and double-strand DNA breaks. Alternatively, exposure to environmental pollutants, radiation or ultra-violet light, can also contribute to exogenously derived DNA damage. We previously validated a novel, high through-put approach to measure levels of DNA damage in cultured mammalian cells. This new CometChip Platform builds on the classical single cell gel electrophoresis or comet methodology used extensively in environmental toxicology and molecular biology. We asked whether the CometChip Platform could be used to measure DNA damage in samples derived from environmental field studies. To this end, we determined that nucleated erythrocytes from multiple species of turtle could be successfully evaluated in the CometChip Platform to quantify levels of DNA damage. In total, we compared levels of DNA damage in 40 animals from two species: the box turtle (Terrapene carolina) and the red-eared slider (Trachemys scripta elegans). Endogenous levels of DNA damage were identical between the two species, yet we did discover some sex-linked differences and changes in DNA damage accumulation. Based on these results, we confirm that the CometChip Platform allows for the measurement of DNA damage in a large number of samples quickly and accurately, and is particularly adaptable to environmental studies using field-collected samples. Environ. Mol. Mutagen. 59:322-333, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  12. Implementation of a Multichannel Serial Data Streaming Algorithm using the Xilinx Serial RapidIO Solution

    Science.gov (United States)

    Doxley, Charles A.

    2016-01-01

    In the current world of applications that use reconfigurable technology implemented on field programmable gate arrays (FPGAs), there is a need for flexible architectures that can grow as the systems evolve. A project has limited resources and a fixed set of requirements that development efforts are tasked to meet. Designers must develop robust solutions that practically meet the current customer demands and also have the ability to grow for future performance. This paper describes the development of a high speed serial data streaming algorithm that allows for transmission of multiple data channels over a single serial link. The technique has the ability to change to meet new applications developed for future design considerations. This approach uses the Xilinx Serial RapidIO LOGICORE Solution to implement a flexible infrastructure to meet the current project requirements with the ability to adapt future system designs.

  13. Analysis of XFEL serial diffraction data from individual crystalline fibrils

    Directory of Open Access Journals (Sweden)

    David H. Wojtas

    2017-11-01

    Full Text Available Serial diffraction data collected at the Linac Coherent Light Source from crystalline amyloid fibrils delivered in a liquid jet show that the fibrils are well oriented in the jet. At low fibril concentrations, diffraction patterns are recorded from single fibrils; these patterns are weak and contain only a few reflections. Methods are developed for determining the orientation of patterns in reciprocal space and merging them in three dimensions. This allows the individual structure amplitudes to be calculated, thus overcoming the limitations of orientation and cylindrical averaging in conventional fibre diffraction analysis. The advantages of this technique should allow structural studies of fibrous systems in biology that are inaccessible using existing techniques.

  14. Split-plot designs for robotic serial dilution assays.

    Science.gov (United States)

    Buzas, Jeffrey S; Wager, Carrie G; Lansky, David M

    2011-12-01

    This article explores effective implementation of split-plot designs in serial dilution bioassay using robots. We show that the shortest path for a robot to fill plate wells for a split-plot design is equivalent to the shortest common supersequence problem in combinatorics. We develop an algorithm for finding the shortest common supersequence, provide an R implementation, and explore the distribution of the number of steps required to implement split-plot designs for bioassay through simulation. We also show how to construct collections of split plots that can be filled in a minimal number of steps, thereby demonstrating that split-plot designs can be implemented with nearly the same effort as strip-plot designs. Finally, we provide guidelines for modeling data that result from these designs. © 2011, The International Biometric Society.

  15. Establishment of human iPSC line NCCSi003-A from CD34+cells of peripheral blood collected during apheresis of healthy donor from Indian ethnicity

    Directory of Open Access Journals (Sweden)

    Sophia Fernandes

    2018-03-01

    Full Text Available We present generation of iPSCs from CD34+ cells isolated from peripheral blood, collected during apheresis of a healthy female individual. We nucleofected the CD34+cells by episomal vectors containing Oct4, Sox2, L-Myc, Lin28, Klf4 and p53DD (dominant negative mutation in p53. The resultant colonies showed cobble-stone appearance and stained positive for alkaline phosphatase. The colonies demonstrated presence of pluripotency markers by immunofluorescence, flow-cytometry and PCR. The plasmids were lost from cells subsequently during passages as assessed by PCR. Karyotype analysis demonstrated a stable genome. The cells had capability to differentiate to cells from all three-germ lineages in vitro.

  16. Dried Blood Spots, an Affordable Tool to Collect, Ship, and Sequence gDNA from Patients with an X-Linked Agammaglobulinemia Phenotype Residing in a Developing Country

    Directory of Open Access Journals (Sweden)

    Gesmar R. S. Segundo

    2018-02-01

    Full Text Available BackgroundNew sequencing techniques have revolutionized the identification of the molecular basis of primary immunodeficiency disorders (PID not only by establishing a gene-based diagnosis but also by facilitating defect-specific treatment strategies, improving quality of life and survival, and allowing factual genetic counseling. Because these techniques are generally not available for physicians and their patients residing in developing countries, collaboration with overseas laboratories has been explored as a possible, albeit cumbersome, strategy. To reduce the cost of time and temperature-sensitive shipping, we selected Guthrie cards, developed for newborn screening, to collect dried blood spots (DBS, as a source of DNA that can be shipped by regular mail at minimal cost.MethodBlood was collected and blotted onto the filter paper of Guthrie cards by completely filling three circles. We enrolled 20 male patients with presumptive X-linked agammaglobulinemia (XLA cared for at the Vietnam National Children’s Hospital, their mothers, and several sisters for carrier analysis. DBS were stored at room temperature until ready to be shipped together, using an appropriately sized envelope, to a CLIA-certified laboratory in the US for sequencing. The protocol for Sanger sequencing was modified to account for the reduced quantity of gDNA extracted from DBS.ResultHigh-quality gDNA could be extracted from every specimen. Bruton tyrosine kinase (BTK mutations were identified in 17 of 20 patients studied, confirming the diagnosis of XLA in 85% of the study cohort. Type and location of the mutations were similar to those reported in previous reviews. The mean age when XLA was suspected clinically was 4.6 years, similar to that reported by Western countries. Two of 15 mothers, each with an affected boy, had a normal BTK sequence, suggesting gonadal mosaicism.ConclusionDBS collected on Guthrie cards can be shipped inexpensively by airmail across continents

  17. Cord blood collection and banking from a population with highly diverse geographic origins increase HLA diversity in the registry and do not lower the proportion of validated cord blood units: experience of the Marseille Cord Blood Bank.

    Science.gov (United States)

    Bordoni, C; Magalon, J; Gilbertas, C; Gamerre, M; Le Coz, P; Berthomieu, M; Chabannon, C; Di Cristofaro, J; Picard, C

    2015-04-01

    Several Cord Blood (CB) Bank studies suggested that ethnicity impaired CB unit (CBU) qualification. The Bone Marrow Donors Worldwide registries present an over-representation of unrelated donors (UD) from Northwestern European descent. This raises the question of equality of access to hematopoietic stem cells transplant, especially in the Mediterranean zone, which has taken in many waves of immigration. The aim of our study is to address whether, in the Marseille CB Bank, CBU qualification rate is impaired by geographic origin. The study compared biological characteristics of 106 CBU disqualified for total nucleated cell (TNC) count (dCBU) and 136 qualified CBU in relation to registry enrichment and haplotype origin. A high proportion (>80%) of both dCBU and CBU had at least one non-European haplotype and enrich CB and UD registries to a higher extent than those with two European haplotypes (Pdiverse Mediterranean origins do not have an impact on the CBU qualification rate. Partnership with Mediterranean birth clinics with highly trained staff is a reasonable option to increase the HLA diversity of CB Bank inventories and to improve the representation of minorities.

  18. Energy Information Data Base: serial titles

    International Nuclear Information System (INIS)

    1980-06-01

    The Department of Energy Technical Information Center (TIC) is responsible for creating bibliographic data bases that are used in the announcement and retrieval of publications dealing with all phases of energy. The TIC interactive information processing system makes use of a number of computerized authorities so that consistency can be maintained and indexes can be produced. One such authority is the Energy Information Data Base: Serial Titles. This authority contains the full and abbreviated journal title, country of publication, CODEN, and certain codes. This revision replaces previous revisions of this document

  19. Inverse Kinematics of a Serial Robot

    Directory of Open Access Journals (Sweden)

    Amici Cinzia

    2016-01-01

    Full Text Available This work describes a technique to treat the inverse kinematics of a serial manipulator. The inverse kinematics is obtained through the numerical inversion of the Jacobian matrix, that represents the equation of motion of the manipulator. The inversion is affected by numerical errors and, in different conditions, due to the numerical nature of the solver, it does not converge to a reasonable solution. Thus a soft computing approach is adopted to mix different traditional methods to obtain an increment of algorithmic convergence.

  20. Rapid serial visual presentation design for cognition

    CERN Document Server

    Spence, Robert

    2013-01-01

    A powerful new image presentation technique has evolved over the last twenty years, and its value demonstrated through its support of many and varied common tasks. Conceptually, Rapid Serial Visual Presentation (RSVP) is basically simple, exemplified in the physical world by the rapid riffling of the pages of a book in order to locate a known image. Advances in computation and graphics processing allow RSVP to be applied flexibly and effectively to a huge variety of common tasks such as window shopping, video fast-forward and rewind, TV channel selection and product browsing. At its heart is a

  1. CAR-T cells are serial killers.

    Science.gov (United States)

    Davenport, Alexander J; Jenkins, Misty R; Ritchie, David S; Prince, H Miles; Trapani, Joseph A; Kershaw, Michael H; Darcy, Phillip K; Neeson, Paul J

    2015-12-01

    Chimeric antigen receptor (CAR) T cells have enjoyed unprecedented clinical success against haematological malignancies in recent years. However, several aspects of CAR T cell biology remain unknown. We recently compared CAR and T cell receptor (TCR)-based killing in the same effector cell and showed that CAR T cells can not only efficiently kill single tumor targets, they can also kill multiple tumor targets in a sequential manner. Single and serial killing events were not sustained long term due to CAR down-regulation after 20 hours.

  2. Personality disorders, psychopathy and serial killers

    OpenAIRE

    Morana, Hilda C P; Stone, Michael H; Abdalla-Filho, Elias

    2006-01-01

    OBJETIVO: Apresentar as características básicas dos diversos transtornos específicos de personalidade, mas centrando-se no transtorno de personalidade anti-social, fazendo sua diferenciação com psicopatia. O estudo ainda se propõe a abordar a figura do serial killer, apontando a presença de aspectos psicopáticos no homicídio seriado. MÉTODO: Uma revisão bibliográfica foi feita no sentido de se abordar convergências e divergências entre diversos autores sobre um assunto tão polêmico, sobretudo...

  3. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

    Energy Technology Data Exchange (ETDEWEB)

    Coquelle, Nicolas [Université Grenoble Alpes, IBS, 38044 Grenoble (France); CNRS, IBS, 38044 Grenoble (France); CEA, IBS, 38044 Grenoble (France); Brewster, Aaron S. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Kapp, Ulrike; Shilova, Anastasya; Weinhausen, Britta [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Burghammer, Manfred, E-mail: burgham@esrf.fr [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Ghent University, Ghent B-9000 (Belgium); Colletier, Jacques-Philippe, E-mail: burgham@esrf.fr [Université Grenoble Alpes, IBS, 38044 Grenoble (France); CNRS, IBS, 38044 Grenoble (France); CEA, IBS, 38044 Grenoble (France)

    2015-05-01

    A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

  4. Serial crystallography captures enzyme catalysis in copper nitrite reductase at atomic resolution from one crystal

    Directory of Open Access Journals (Sweden)

    Sam Horrell

    2016-07-01

    Full Text Available Relating individual protein crystal structures to an enzyme mechanism remains a major and challenging goal for structural biology. Serial crystallography using multiple crystals has recently been reported in both synchrotron-radiation and X-ray free-electron laser experiments. In this work, serial crystallography was used to obtain multiple structures serially from one crystal (MSOX to study in crystallo enzyme catalysis. Rapid, shutterless X-ray detector technology on a synchrotron MX beamline was exploited to perform low-dose serial crystallography on a single copper nitrite reductase crystal, which survived long enough for 45 consecutive 100 K X-ray structures to be collected at 1.07–1.62 Å resolution, all sampled from the same crystal volume. This serial crystallography approach revealed the gradual conversion of the substrate bound at the catalytic type 2 Cu centre from nitrite to nitric oxide, following reduction of the type 1 Cu electron-transfer centre by X-ray-generated solvated electrons. Significant, well defined structural rearrangements in the active site are evident in the series as the enzyme moves through its catalytic cycle, namely nitrite reduction, which is a vital step in the global denitrification process. It is proposed that such a serial crystallography approach is widely applicable for studying any redox or electron-driven enzyme reactions from a single protein crystal. It can provide a `catalytic reaction movie' highlighting the structural changes that occur during enzyme catalysis. The anticipated developments in the automation of data analysis and modelling are likely to allow seamless and near-real-time analysis of such data on-site at some of the powerful synchrotron crystallographic beamlines.

  5. Galileo - The Serial-Production AIT Challenge

    Science.gov (United States)

    Ragnit, Ulrike; Brunner, Otto

    2008-01-01

    The Galileo Project is one of the most demanding projects of ESA, being Europe's autarkic navigation system and a constellation composed of 30 satellites. This presentation points out the different phases of the project up to the full operational capability and the corresponding launch options with respect to launch vehicles as well as launch configurations. One of the biggest challenges is to set up a small serial 'production line' for the overall integration and test campaign of satellites. This production line demands an optimization of all relevant tasks, taking into account also backup and recovery actions. A comprehensive AIT concept is required, reflecting a tightly merged facility layout and work flow design. In addition a common data management system is needed to handle all spacecraft related documentation and to have a direct input-out flow for all activities, phases and positions at the same time. Process optimization is a well known field of engineering in all small high tech production lines, nevertheless serial production of satellites are still not the daily task in space business and therefore new concepts have to be put in place. Therefore, and in order to meet the satellites overall system optimization, a thorough interface between unit/subsystem manufacturing and satellite AIT must be realized to ensure a smooth flow and to avoid any process interruption, which would directly lead to a schedule impact.

  6. Spatial serial order processing in schizophrenia.

    Science.gov (United States)

    Fraser, David; Park, Sohee; Clark, Gina; Yohanna, Daniel; Houk, James C

    2004-10-01

    The aim of this study was to examine serial order processing deficits in 21 schizophrenia patients and 16 age- and education-matched healthy controls. In a spatial serial order working memory task, one to four spatial targets were presented in a randomized sequence. Subjects were required to remember the locations and the order in which the targets were presented. Patients showed a marked deficit in ability to remember the sequences compared with controls. Increasing the number of targets within a sequence resulted in poorer memory performance for both control and schizophrenia subjects, but the effect was much more pronounced in the patients. Targets presented at the end of a long sequence were more vulnerable to memory error in schizophrenia patients. Performance deficits were not attributable to motor errors, but to errors in target choice. The results support the idea that the memory errors seen in schizophrenia patients may be due to saturating the working memory network at relatively low levels of memory load.

  7. Serial position curves in free recall.

    Science.gov (United States)

    Laming, Donald

    2010-01-01

    The scenario for free recall set out in Laming (2009) is developed to provide models for the serial position curves from 5 selected sets of data, for final free recall, and for multitrial free recall. The 5 sets of data reflect the effects of rate of presentation, length of list, delay of recall, and suppression of rehearsal. Each model accommodates the serial position curve for first recalls (where those data are available) as well as that for total recalls. Both curves are fit with the same parameter values, as also (with 1 exception) are all of the conditions compared within each experiment. The distributions of numbers of recalls are also examined and shown to have variances increased above what would be expected if successive recalls were independent. This is taken to signify that, in those experiments in which rehearsals were not recorded, the retrieval of words for possible recall follows the same pattern that is observed following overt rehearsal, namely, that retrieval consists of runs of consecutive elements from memory. Finally, 2 sets of data are examined that the present approach cannot accommodate. It is argued that the problem with these data derives from an interaction between the patterns of (covert) rehearsal and the parameters of list presentation.

  8. Malingering, coaching, and the serial position effect.

    Science.gov (United States)

    Suhr, Julie A

    2002-01-01

    The normal pattern of performance on list-learning tasks is to recall more words from the beginning (primacy) and end (recency) of the list. This pattern is also seen in patients with closed head injury, but malingerers tend to recall less words from the beginning of word lists, leading to a suppressed primacy effect. The present study examined this pattern on both learning trials and delayed recall of the Auditory Verbal Learning Test (AVLT) in 34 persons performing with normal effort, 38 naive malingerers, 33 warned malingerers, and 29 head-injured patients. Both malingering groups had lower scores on the primacy portion of the list during learning trials, while normals and head-injured patients had normal serial position curves. During delayed recall, normals and head-injured patients did better than the two malingering groups on middle and recency portions of the list. Findings suggest that the serial position effect during learning trials may be a useful pattern of performance to watch for when suspicious of malingering.

  9. Rapid-Sequence Serial Sexual Homicides.

    Science.gov (United States)

    Schlesinger, Louis B; Ramirez, Stephanie; Tusa, Brittany; Jarvis, John P; Erdberg, Philip

    2017-03-01

    Serial sexual murderers have been described as committing homicides in a methodical manner, taking substantial time between offenses to elude the authorities. The results of our study of the temporal patterns (i.e., the length of time between homicides) of a nonrandom national sample of 44 serial sexual murderers and their 201 victims indicate that this representation may not always be accurate. Although 25 offenders (56.8%) killed with longer than a 14-day period between homicides, a sizeable subgroup was identified: 19 offenders (43.2%) who committed homicides in rapid-sequence fashion, with fewer than 14 days between all or some of the murders. Six offenders (13.6%) killed all their victims in one rapid-sequence, spree-like episode, with homicides just days apart or sometimes two murders in the same day. Thirteen offenders (29.5%) killed in one or two rapid-sequence clusters (i.e., more than one murder within a 14-day period, as well as additional homicides with greater than 14 days between each). The purpose of our study was to describe this subgroup of rapid-sequence offenders who have not been identified until now. These findings argue for accelerated forensic assessments of dangerousness and public safety when a sexual murder is detected. Psychiatric disorders with rapidly occurring symptom patterns, or even atypical mania or mood dysregulation, may serve as exemplars for understanding this extraordinary group of offenders. © 2017 American Academy of Psychiatry and the Law.

  10. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  11. CMOS serial link for fully duplexed data communication

    Science.gov (United States)

    Lee, Kyeongho; Kim, Sungjoon; Ahn, Gijung; Jeong, Deog-Kyoon

    1995-04-01

    This paper describes a CMOS serial link allowing fully duplexed 500 Mbaud serial data communication. The CMOS serial link is a robust and low-cost solution to high data rate requirements. A central charge pump PLL for generating multiphase clocks for oversampling is shared by several serial link channels. Fully duplexed serial data communication is realized in the bidirectional bridge by separating incoming data from the mixed signal on the cable end. The digital PLL accomplishes process-independent data recovery by using a low-ratio oversampling, a majority voting, and a parallel data recovery scheme. Mostly, digital approach could extend its bandwidth further with scaled CMOS technology. A single channel serial link and a charge pump PLL are integrated in a test chip using 1.2 micron CMOS process technology. The test chip confirms upto 500 Mbaud unidirectional mode operation and 320 Mbaud fully duplexed mode operation with pseudo random data patterns.

  12. CAMAC serial highway interface for the LSI-11

    International Nuclear Information System (INIS)

    Lau, N.H.

    1980-01-01

    A CAMAC Serial Highway Interface has been designed for the Local Control and Instrumentation System of the Mirror Fusion Test Facility. There are over 50 distinguishable systems in the facility, each of which consists of the LSI-11 computer, fiber optic communication links, and the CAMAC system. The LSI-11 computer includes a 32k memory, serial modem interface and the CAMAC Serial Highway Interface

  13. Implementation of Serial and Parallel Bubble Sort on Fpga

    OpenAIRE

    Purnomo, Dwi Marhaendro Jati; Arinaldi, Ahmad; Priyantini, Dwi Teguh; Wibisono, Ari; Febrian, Andreas

    2016-01-01

    Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort r...

  14. Representation of the serial killer on the Italian Internet.

    Science.gov (United States)

    Villano, P; Bastianoni, P; Melotti, G

    2001-10-01

    The representation of serial killers was examined from the analysis of 317 Web pages in the Italian language to study how the psychological profiles of serial killers are described on the Italian Internet. The correspondence analysis of the content of these Web pages shows that in Italy the serial killer is associated with words such as "monster" and "horror," which suggest and imply psychological perversion and aberrant acts. These traits are peculiar for the Italian scenario.

  15. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    Science.gov (United States)

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  16. IMPLEMENTATION OF SERIAL AND PARALLEL BUBBLE SORT ON FPGA

    Directory of Open Access Journals (Sweden)

    Dwi Marhaendro Jati Purnomo

    2016-06-01

    Full Text Available Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort required smaller memory as well as utility compared to parallel bubble sort. Meanwhile, parallel bubble sort performed faster than serial bubble sort

  17. A psychological profile of a serial killer: a case report.

    Science.gov (United States)

    Dogra, T D; Leenaars, Antoon A; Chadha, R K; Manju, Mehta; Lalwani, Sanjeev; Sood, Mamta; Lester, David; Raina, Anupuma; Behera, C

    2012-01-01

    Serial killers have always fascinated society. A serial killer is typically defined as a perpetrator who murders three or more people over a period of time. Most reported cases of serial killers come from the United States and Canada. In India, there are few reported cases. We present, to the best of our knowledge, the first Indian case in the literature. The present case is of a 28-year-old man, Surinder Koli. The Department of Forensic Medicine & Toxicology, All India Institute of Medical Sciences, New Delphi handled the forensic study. We present a most unique psychological investigation into the mind of a serial killer.

  18. Malignant sex and aggression: an overview of serial sexual homicide.

    Science.gov (United States)

    Myers, W C; Reccoppa, L; Burton, K; McElroy, R

    1993-01-01

    Serial murderers have attracted considerable attention in the popular press and criminal justice field, but scientific literature about these individuals is limited. This article provides an overview, from a psychiatric perspective, of serial sexual homicide, one type of serial killing. Characteristics of this type of murder and of these offenders are discussed. Defining qualities and diagnoses applicable to serial sexual killers are reviewed. Various etiologic theories are discussed, with emphasis on the role of fantasy and psychodynamic explanations. Governmental agencies involved in combating this type of crime, along with the role of mental health professionals in criminal profiling, are presented. Finally, the authors explore the reaction of society to this phenomenon.

  19. AhR- and ER-mediated activities in human blood samples collected from PCB-contaminated and background region in Slovakia

    Energy Technology Data Exchange (ETDEWEB)

    Pliskova, M. [Veterinary Researcch Institute, Brno (Czech Republic); Canton, R.F.; Duursen, M.B.M. van [Utrecht Univ. (NL). Institute for Risk Assessment Sciences (IRAS)] (and others)

    2004-09-15

    Endocrine disruption mediated through activation of aryl hydrocarbon receptor (AhR) and estrogen receptor (ER) by polychlorinated biphenyls (PCBs) and other persistent organic pollutants (POPs) has been studied extensively both in vivo and in vitro. Non-ortho- and mono-ortho-substituted polychlorinated biphenyls (PCBs) are potent AhR agonists therefore, increased dioxin-like activity of complex blood samples might reflect an increased exposure to PCBs. The induction of expression of CYP1A1 and CYP1B1 in different tissues, including lymphocytes, also depends on activation of AhR and it could be useful as a potential biomarker of exposure to dioxin-like compounds. Using various in vivo and in vitro models, the exposure to PCBs or hydroxy-PCBs has been reported to lead to either induction of ER-mediated activity or to an antiestrogenic effect associated with a suppression of estradiol-induced ER-dependent gene expression. Nevertheless, relative (anti)estrogenic potencies of a large set of prevalent environmental PCBs have not been yet compared in a single bioassay. A cross-talk between AhR and ER has been suggested to lead to a suppression of ER-mediated gene expression. Therefore, presence of dioxin-like compounds in blood could potentially suppress the ER-mediated activity. Additionally, AhR-dependent induction of CYP1A1 and especially CYP1B1, two enzymes involved in oxidative metabolism of estradiol and other estrogens, might enhance the metabolism of estradiol and it has been suggested to cause a potential depression of estrogen levels in the body. The aim of the present study was to determine dioxin-like, estrogenic and antiestrogenic activities in human blood samples collected in two Eastern Slovakia regions differently polluted with PCBs using established in vitro bioassays. We also studied mRNA expression of CYP1A1 and 1B1 in lymphocytes and the genotypes of CYP1B1 as possible biomarkers of exposure for PCBs and related compounds. The biological data obtained

  20. Woody Allen, serial schlemiel ?

    Directory of Open Access Journals (Sweden)

    Frédérique Brisset

    2011-04-01

    Full Text Available Woody Allen a développé au fil des années une persona cinématographique de schlemiel new-yorkais aisément reconnaissable par le spectateur. Elle marque nombre de ses films, qu’il y apparaisse en tant qu’acteur ou y dirige des substituts comédiens comme déclinaisons de lui-même. Si cette figure prototypique est le fondement de la sérialité dans sa filmographie, il est des traits stylistiques qui en portent trace tout au long de son œuvre : la récurrence annuelle de ses réalisations, la signature formelle symbolisée par ses génériques à la typographie singulière, le rythme de ses dialogues ponctués d’interjections et l’usage de l’autocitation sont autant de procédés qui marquent son cinéma d’un sceau très personnel. Ils fonctionnent comme des clins d’œil au spectateur qui reçoit dès lors LE Woody Allen millésimé comme une invitation à retrouver son microcosme. Ainsi la sérialité se pose comme à la fois initiale et conséquentielle de son système filmique, processus de création unique dans le cinéma américain.Woody Allen has long constructed a cinematographic persona of schlemiel New- Yorker that the audience can easily identify. It impacts most of his films, whether he stars in them or directs “substitute” actors to impersonate his character. If this prototypical figure is the basis of seriality in his cinematography, serial stylistic features can also be found all along his career: the annual recurrence of his productions, the formal signature symbolised by the typography of his singular credit titles, his rhythmical interjection-punctuated dialogues and the use of self-quotation imprint a very personal seal upon his movies. They all work as a recognition signals for the audience who thus receive THE Woody Allen vintage as an invitation to re-enter his microcosm. Seriality is then both initial and consequential to his cinematographic system, a unique creative process in American film history.

  1. Serial binary interval ratios improve rhythm reproduction.

    Science.gov (United States)

    Wu, Xiang; Westanmo, Anders; Zhou, Liang; Pan, Junhao

    2013-01-01

    Musical rhythm perception is a natural human ability that involves complex cognitive processes. Rhythm refers to the organization of events in time, and musical rhythms have an underlying hierarchical metrical structure. The metrical structure induces the feeling of a beat and the extent to which a rhythm induces the feeling of a beat is referred to as its metrical strength. Binary ratios are the most frequent interval ratio in musical rhythms. Rhythms with hierarchical binary ratios are better discriminated and reproduced than rhythms with hierarchical non-binary ratios. However, it remains unclear whether a superiority of serial binary over non-binary ratios in rhythm perception and reproduction exists. In addition, how different types of serial ratios influence the metrical strength of rhythms remains to be elucidated. The present study investigated serial binary vs. non-binary ratios in a reproduction task. Rhythms formed with exclusively binary (1:2:4:8), non-binary integer (1:3:5:6), and non-integer (1:2.3:5.3:6.4) ratios were examined within a constant meter. The results showed that the 1:2:4:8 rhythm type was more accurately reproduced than the 1:3:5:6 and 1:2.3:5.3:6.4 rhythm types, and the 1:2.3:5.3:6.4 rhythm type was more accurately reproduced than the 1:3:5:6 rhythm type. Further analyses showed that reproduction performance was better predicted by the distribution pattern of event occurrences within an inter-beat interval, than by the coincidence of events with beats, or the magnitude and complexity of interval ratios. Whereas rhythm theories and empirical data emphasize the role of the coincidence of events with beats in determining metrical strength and predicting rhythm performance, the present results suggest that rhythm processing may be better understood when the distribution pattern of event occurrences is taken into account. These results provide new insights into the mechanisms underlining musical rhythm perception.

  2. Serial binary interval ratios improve rhythm reproduction

    Directory of Open Access Journals (Sweden)

    Xiang eWu

    2013-08-01

    Full Text Available Musical rhythm perception is a natural human ability that involves complex cognitive processes. Rhythm refers to the organization of events in time, and musical rhythms have an underlying hierarchical metrical structure. The metrical structure induces the feeling of a beat and the extent to which a rhythm induces the feeling of a beat is referred to as its metrical strength. Binary ratios are the most frequent interval ratio in musical rhythms. Rhythms with hierarchical binary ratios are better discriminated and reproduced than rhythms with hierarchical non-binary ratios. However, it remains unclear whether a superiority of serial binary over non-binary ratios in rhythm perception and reproduction exists. In addition, how different types of serial ratios influence the metrical strength of rhythms remains to be elucidated. The present study investigated serial binary vs. non-binary ratios in a reproduction task. Rhythms formed with exclusively binary (1:2:4:8, non-binary integer (1:3:5:6, and non-integer (1:2.3:5.3:6.4 ratios were examined within a constant meter. The results showed that the 1:2:4:8 rhythm type was more accurately reproduced than the 1:3:5:6 and 1:2.3:5.3:6.4 rhythm types, and the 1:2.3:5.3:6.4 rhythm type was more accurately reproduced than the 1:3:5:6 rhythm type. Further analyses showed that reproduction performance was better predicted by the distribution pattern of event occurrences within an inter-beat interval, than by the coincidence of events with beats, or the magnitude and complexity of interval ratios. Whereas rhythm theories and empirical data emphasize the role of the coincidence of events with beats in determining metrical strength and predicting rhythm performance, the present results suggest that rhythm processing may be better understood when the distribution pattern of event occurrences is taken into account. These results provide new insights into the mechanisms underlining musical rhythm perception.

  3. Catalog of the George Alan Connor Esperanto Collection.

    Science.gov (United States)

    Smith, Karin, Comp.; Haake, Susan, Comp.

    This catalog inventories the collection of books, monographs, serials and periodicals, dictionaries, pamphlets, ephemera, and correspondence concerning Esperanto in the collection of George Alan Connor housed at the University of Oregon Library. Overall, the catalog contains approximately 475 serial entries and 3,000 author entries. Connor was a…

  4. KANBAN allocation in a serial suply chain

    Directory of Open Access Journals (Sweden)

    Guillermo Andrés Sánchez C.

    2012-06-01

    Full Text Available The aim of this project is to simulate a Kanban system using N stages with the objective of maintaining an acceptable throughput and mean system time. The document shows the production systems where Kanban is applicable and what the potential benefits are. A serial of simulations will be done using a demand given by a poison distribution with rate λ ^ ext. The simulation aimed to find the best number of withdrawal Kanban on all stages when the values of μ (for exponential distribution of the process and λ ^ ext increase and decrease. At the end of this simulation, the best way to allocate the withdrawal Kanban over N stages with the objective of maintaining acceptable throughput and mean system time will be clearer thus the conclusions of this work will be done.

  5. Serial CT scannings in herpes simplex encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Fukushima, M.; Sawada, T.; Kuriyama, Y.; Kinugawa, H.; Yamaguchi, T. (National Cardivascular Center, Osaka (Japan))

    1981-10-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemiparesis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis.

  6. Serial CT scannings in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Fukushima, Masashi; Sawada, Tohru; Kuriyama, Yoshihiro; Kinugawa, Hidekazu; Yamaguchi, Takenori

    1981-01-01

    Two patients with serologically confirmed herpes simplex encephalitis were studied by serial CT scannings. Case 1, a 60-year-old woman, was admitted to National Cardiovascular Center because of headache, fever, and attacks of Jacksonian seizure. Case 2, a 54-year-old man, was admitted because of fever, consciousness disturbance and right hemipare sis. Pleocytosis (mainly lymphocytes) and elevation of protein content in cerebrospinal fluid were observed in both cases. Both patients presented ''das apallische Syndrom'' one month after admission. The diagnosis of herpes simplex encephalitis was confirmed by typical clinical courses and by greater than fourfold rises in serum antibody titer for herpes simplex virus as well as that in cerebrospinal fluid in case 1. Characteristic CT findings observed in these two cases were summarized as follows: Within a week after the onset, no obvious abnormalities could be detected on CT scans (Case 1). Two weeks after the onset, a large low-density area appeared in the left temporal lobe and in the contralateral insular cortex with midline shift toward the right side (Case 2). One month later, an ill-defined linear and ring-like high-density area (Case 1), or a well-defined high-density area (Case 2), that was enhanced after contrast administration, was observed in the large low-density area in the temporal lobe. These findings were considered as characteristic for hemorrhagic encephalitis. These high-density areas disappeared two months later, however, widespread and intensified low-density areas still remained. In both cases, the basal ganglia and thalamus were completely spared on CT scans. From these observations, it can be concluded that serial CT scannings are quite useful for diagnosis of herpes simplex encephalitis. (author)

  7. Handbook of serial communications interfaces a comprehensive compendium of serial digital input/output (I/O) standards

    CERN Document Server

    Frenzel, Louis

    2015-01-01

    This book catalogs the most popular and commonly used serial-port interfaces and provides details on the specifications and the latest standards, enabling you to select an interface for a new design or verify that an interface is working correctly. Each chapter is based on a different interface and is written in an easy to follow, standard format. With this book you will learn: The most widely used serial interfacesHow to select the best serial interface for a specific application or designThe trade-offs between data rate and distance (length or range)The operation and benefits of serial

  8. Is Serial Testing Required to Diagnose Imported Malaria in the Era of Rapid Diagnostic Tests?

    Science.gov (United States)

    Pasricha, Janet M.; Juneja, Surender; Manitta, Joseph; Whitehead, Susan; Maxwell, Ellen; Goh, Wai-Keong; Pasricha, Sant-Rayn; Eisen, Damon P.

    2013-01-01

    Exclusion of malaria traditionally requires three negative serial thick and thin blood films. However, many clinical laboratories now routinely perform rapid diagnostic tests (RDTs) in addition to blood films when malaria is suspected. We sought to determine whether serial testing is necessary in this setting. We examined 388 cases of malaria diagnosed during 1999–2010 at three laboratories in Melbourne, Australia. For each case, we ascertained whether the diagnosis was made on initial or follow-up testing. Nine cases (3.5%) were diagnosed after a negative initial blood film and RDT: 7 Plasmodium vivax, 1 P. ovale, and 1 P. falciparum. Of four case-patients with P. vivax in which clinical data were available, all had recent exposure to antimalarial medication. Our data suggest that among patients who have not received recent anti-malarial therapy, and when RDTs are performed and blood films are prepared, most malaria diagnoses are made by using the first set of tests. PMID:23208885

  9. Technical note: An inverse method to relate organic carbon reactivity to isotope composition from serial oxidation

    Directory of Open Access Journals (Sweden)

    J. D. Hemingway

    2017-11-01

    Full Text Available Serial oxidation coupled with stable carbon and radiocarbon analysis of sequentially evolved CO2 is a promising method to characterize the relationship between organic carbon (OC chemical composition, source, and residence time in the environment. However, observed decay profiles depend on experimental conditions and oxidation pathway. It is therefore necessary to properly assess serial oxidation kinetics before utilizing decay profiles as a measure of OC reactivity. We present a regularized inverse method to estimate the distribution of OC activation energy (E, a proxy for bond strength, using serial oxidation. Here, we apply this method to ramped temperature pyrolysis or oxidation (RPO analysis but note that this approach is broadly applicable to any serial oxidation technique. RPO analysis directly compares thermal reactivity to isotope composition by determining the E range for OC decaying within each temperature interval over which CO2 is collected. By analyzing a decarbonated test sample at multiple masses and oven ramp rates, we show that OC decay during RPO analysis follows a superposition of parallel first-order kinetics and that resulting E distributions are independent of experimental conditions. We therefore propose the E distribution as a novel proxy to describe OC thermal reactivity and suggest that E vs. isotope relationships can provide new insight into the compositional controls on OC source and residence time.

  10. Technical note: An inverse method to relate organic carbon reactivity to isotope composition from serial oxidation

    Science.gov (United States)

    Hemingway, Jordon D.; Rothman, Daniel H.; Rosengard, Sarah Z.; Galy, Valier V.

    2017-11-01

    Serial oxidation coupled with stable carbon and radiocarbon analysis of sequentially evolved CO2 is a promising method to characterize the relationship between organic carbon (OC) chemical composition, source, and residence time in the environment. However, observed decay profiles depend on experimental conditions and oxidation pathway. It is therefore necessary to properly assess serial oxidation kinetics before utilizing decay profiles as a measure of OC reactivity. We present a regularized inverse method to estimate the distribution of OC activation energy (E), a proxy for bond strength, using serial oxidation. Here, we apply this method to ramped temperature pyrolysis or oxidation (RPO) analysis but note that this approach is broadly applicable to any serial oxidation technique. RPO analysis directly compares thermal reactivity to isotope composition by determining the E range for OC decaying within each temperature interval over which CO2 is collected. By analyzing a decarbonated test sample at multiple masses and oven ramp rates, we show that OC decay during RPO analysis follows a superposition of parallel first-order kinetics and that resulting E distributions are independent of experimental conditions. We therefore propose the E distribution as a novel proxy to describe OC thermal reactivity and suggest that E vs. isotope relationships can provide new insight into the compositional controls on OC source and residence time.

  11. RProtoBuf: Efficient Cross-Language Data Serialization in R

    Directory of Open Access Journals (Sweden)

    Dirk Eddelbuettel

    2016-07-01

    Full Text Available Modern data collection and analysis pipelines often involve a sophisticated mix of applications written in general purpose and specialized programming languages. Many formats commonly used to import and export data between different programs or systems, such as CSV or JSON, are verbose, inefficient, not type-safe, or tied to a specific programming language. Protocol Buffers are a popular method of serializing structured data between applications - while remaining independent of programming languages or operating systems. They offer a unique combination of features, performance, and maturity that seems particularly well suited for data-driven applications and numerical computing. The RProtoBuf package provides a complete interface to Protocol Buffers from the R environment for statistical computing. This paper outlines the general class of data serialization requirements for statistical computing, describes the implementation of the RProtoBuf package, and illustrates its use with example applications in large-scale data collection pipelines and web services.

  12. Serial Analysis of Gene Expression: Applications in Human Studies

    Directory of Open Access Journals (Sweden)

    Tuteja Renu

    2004-01-01

    Full Text Available Serial analysis of gene expression (SAGE is a powerful tool, which provides quantitative and comprehensive expression profile of genes in a given cell population. It works by isolating short fragments of genetic information from the expressed genes that are present in the cell being studied. These short sequences, called SAGE tags, are linked together for efficient sequencing. The frequency of each SAGE tag in the cloned multimers directly reflects the transcript abundance. Therefore, SAGE results in an accurate picture of gene expression at both the qualitative and the quantitative levels. It does not require a hybridization probe for each transcript and allows new genes to be discovered. This technique has been applied widely in human studies and various SAGE tags/SAGE libraries have been generated from different cells/tissues such as dendritic cells, lung fibroblast cells, oocytes, thyroid tissue, B-cell lymphoma, cultured keratinocytes, muscles, brain tissues, sciatic nerve, cultured Schwann cells, cord blood-derived mast cells, retina, macula, retinal pigment epithelial cells, skin cells, and so forth. In this review we present the updated information on the applications of SAGE technology mainly to human studies.

  13. A Retrospective Review of the Clinical Characteristics and Blood Glucose Data from Cellnovo System Users using Data Collected from the Cellnovo Online Platform.

    Science.gov (United States)

    Hautier-Suply, Olivia; Friedmann, Yasmin; Shapley, Julian

    2018-04-01

    Technological advances have led to innovative insulin delivery systems for patients with type 1 diabetes mellitus. In particular, the combination of miniature engineering and software algorithms contained in continuous subcutaneous insulin infusion (CSII) system pumps provide the user and the healthcare practitioner with an opportunity to review and adjust blood glucose (BG) levels according to system feedback, and to modify or programme their regimen according to their needs. While CSII pumps record a number of data parameters such as BG level, carbohydrate intake, activity and insulin delivered, these data are generally 'locked in' and can only be accessed by uploading to a cloud-based system, thus information is not contemporaneous. The Cellnovo Diabetes Management System (Cellnovo, Bridgend, UK) allows data to be transmitted securely and wirelessly in real time to a secure server, which is then retrieved by an online platform, the Cellnovo Online platform, enabling continuous access by the user and by clinicians. In this article, the authors describe a retrospective review of the patient data automatically uploaded to the Cellnovo Online platform. Baseline clinical and demographic characteristics collected at the start of pump therapy are shown for all patients, and BG data from a sub-cohort of patients who have been using the system for at least 6 months and who take and record an average of three BG level tests per day are presented to demonstrate glycaemic data over time.

  14. Short- and long-term memory contributions to immediate serial recognition: evidence from serial position effects.

    Science.gov (United States)

    Purser, Harry; Jarrold, Christopher

    2010-04-01

    A long-standing body of research supports the existence of separable short- and long-term memory systems, relying on phonological and semantic codes, respectively. The aim of the current study was to measure the contribution of long-term knowledge to short-term memory performance by looking for evidence of phonologically and semantically coded storage within a short-term recognition task, among developmental samples. Each experimental trial presented 4-item lists. In Experiment 1 typically developing children aged 5 to 6 years old showed evidence of phonologically coded storage across all 4 serial positions, but evidence of semantically coded storage at Serial Positions 1 and 2. In a further experiment, a group of individuals with Down syndrome was investigated as a test case that might be expected to use semantic coding to support short-term storage, but these participants showed no evidence of semantically coded storage and evidenced phonologically coded storage only at Serial Position 4, suggesting that individuals with Down syndrome have a verbal short-term memory capacity of 1 item. Our results suggest that previous evidence of semantic effects on "short-term memory performance" does not reflect semantic coding in short-term memory itself, and provide an experimental method for researchers wishing to take a relatively pure measure of verbal short-term memory capacity, in cases where rehearsal is unlikely.

  15. The Effect of Concurrent Semantic Categorization on Delayed Serial Recall

    Science.gov (United States)

    Acheson, Daniel J.; MacDonald, Maryellen C.; Postle, Bradley R.

    2011-01-01

    The influence of semantic processing on the serial ordering of items in short-term memory was explored using a novel dual-task paradigm. Participants engaged in 2 picture-judgment tasks while simultaneously performing delayed serial recall. List material varied in the presence of phonological overlap (Experiments 1 and 2) and in semantic content…

  16. Effects of Serial Rehearsal Training on Memory Search

    Science.gov (United States)

    McCauley, Charley; And Others

    1976-01-01

    Half the subjects were trained to use a serial rehearsal strategy during target set storage and half were given no strategy training. The results indicate that the rate of memory search is IQ-related, and that serial rehearsal training facilitates memory search when rehearsal is covert. (Author/BW)

  17. Indexing Serialized Fiction: May the Force Be with You.

    Science.gov (United States)

    Barr, Melissa M.

    The adult novel offers indexers an unusual opportunity to create a serialized fiction index. This research paper involved designing and creating a Character Index, Thesaurus, Glossary, and Abstract (with descriptors) for 21 novels based on the "Star Wars" movies. The novels are an unusual example of serialized fiction featuring main…

  18. Infants' Memory Processing of a Serial List: List Length Effects.

    Science.gov (United States)

    Gulya, Michele; Sweeney, Becky; Rovee-Collier, Carolyn

    1999-01-01

    Three experiments demonstrated that increasing the length of a mobile serial list impaired 6-month olds' memory for serial order. Findings indicated that the primacy effect was absent on a 24-hour delayed recognition test and was exhibited on a reactivation test, adding to growing evidence that young infants possess two functionally distinct…

  19. Antisocial personality disorder, sexual sadism, malignant narcissism, and serial murder.

    Science.gov (United States)

    Geberth, V J; Turco, R N

    1997-01-01

    This paper examines the research on serial murder and its relationship to antisocial personality disorder and sexual sadism. The concept of malignant narcissism is also discussed. Case studies of serial killers are examined regarding the nature of sexual violation and crime scene behavior.

  20. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... in the field Hematology 2017 A collection of articles from the 2017 ASH Annual Meeting Education Program Blood: How I Treat A compendium of Blood articles updated to reflect the most recent scientific research ...

  1. Highlights in radiation measuring technique's - Serial Micro Channel SMC 2100

    International Nuclear Information System (INIS)

    Kandler, M.; Hoffmann, Ch.

    2002-01-01

    The Serial Micro Channel SMC 2100 offers an ''intelligent stand alone'' electronics for the radiation measuring technique's. First it is designed of being connected to a serial interface RS232 of a PC. With a RS485 serial interface on a PC, a network structure can be generated. It has all functional modules which are necessary for the measurement of detector signals. Hence it is possible to directly connect any detector for radiation measurement to a PC, laptop, or notebook. All variations can be operated without PC support too. It has a modular structure and consists of two blocks, the functional modules and the basic modules. The Serial Micro Channel SMC 2100 may be directly coupled to a detector, which therefore makes the realisation of an ''intelligent radiation detector'' with serial link RS232 or RS485. (orig.)

  2. Serial Entrepreneurship, Learning by Doing and Self-selection

    DEFF Research Database (Denmark)

    Rocha, Vera; Carneiro, Anabela; Varum, Celeste

    2015-01-01

    of the person-specific effect, using information on individuals’ past histories in paid employment, confirm that serial entrepreneurs exhibit, on average, a larger person-specific effect than non-serial business owners. Moreover, ignoring serial entrepreneurs’ self-selection overestimates learning by doing......It remains a question whether serial entrepreneurs typically perform better than their novice counterparts owing to learning by doing effects or mostly because they are a selected sample of higher-than-average ability entrepreneurs. This paper tries to unravel these two effects by exploring a novel...... empirical strategy based on continuous time duration models with selection. We use a large longitudinal matched employer-employee dataset that allows us to identify about 220,000 individuals who have left their first entrepreneurial experience, out of which over 35,000 became serial entrepreneurs. We...

  3. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  4. Task based synthesis of serial manipulators

    Directory of Open Access Journals (Sweden)

    Sarosh Patel

    2015-05-01

    Full Text Available Computing the optimal geometric structure of manipulators is one of the most intricate problems in contemporary robot kinematics. Robotic manipulators are designed and built to perform certain predetermined tasks. There is a very close relationship between the structure of the manipulator and its kinematic performance. It is therefore important to incorporate such task requirements during the design and synthesis of the robotic manipulators. Such task requirements and performance constraints can be specified in terms of the required end-effector positions, orientations and velocities along the task trajectory. In this work, we present a comprehensive method to develop the optimal geometric structure (DH parameters of a non-redundant six degree of freedom serial manipulator from task descriptions. In this work we define, develop and test a methodology to design optimal manipulator configurations based on task descriptions. This methodology is devised to investigate all possible manipulator configurations that can satisfy the task performance requirements under imposed joint constraints. Out of all the possible structures, the structures that can reach all the task points with the required orientations are selected. Next, these candidate structures are tested to see whether they can attain end-effector velocities in arbitrary directions within the user defined joint constraints, so that they can deliver the best kinematic performance. Additionally least power consuming configurations are also identified.

  5. Serial neuroradiological studies in focal cerebritis

    International Nuclear Information System (INIS)

    Hatta, S.; Mochizuki, H.; Kuru, Y.; Miwa, H.; Kondo, T.; Mori, H.; Mizuno, Y.

    1994-01-01

    We report serial neuroradiological studies in a patient with focal cerebritis in the head of the left caudate nucleus. On the day after the onset of symptoms, CT showed an ill-defined low density lesion. The lack of contrast enhancement appeared to be the most important finding for differentiating focal cerebritis from an encapsulated brain abscess or a tumour. MRI two days later revealed the centre of the lesion to be of slightly low intensity on T1-weighted inversion recovery (IR) images and very low intensity on T2-weighted spin echo images, which appeared to correspond to the early cerebritis stage of experimentally induced cerebritis and brain abscess. Ten days after the onset of symptoms, CT revealed a thin ring of enhancement in the head of the caudate nucleus, and a similar small ring was seen in the hypothalamus 16 days after the onset, corresponding to the late cerebritis stage. MRI nine days later revealed ill-defined high signal lesions within the involved area on the T1-weighted IR images. To our knowledge, this is the first published MRI documentation of the early cerebritis stage developing into an encapsulated brain abscess. The mechanisms underlying of these radiographic changes are discussed. (orig.)

  6. Identification of host blood-meal sources and Borrelia in field-collected Ixodes ricinus ticks in north-western Poland

    Directory of Open Access Journals (Sweden)

    Beata Wodecka

    2015-12-01

    Full Text Available Forest animals play fundamental roles in the maintenance of [i]Ixodes ricinus[/i] and [i]Borrelia[/i] species in the forest biotope. To identify the forest vertebrate species that are host for I. ricinus and for the recognition of the reservoirs of [i]Borrelia[/i] species, the blood-meal of 325 [i]I. ricinus[/i] ticks collected at two forest sites in north-western Poland were analysed. Nested PCR was used to detect polymorphisms in a fragment of the mitochondrial 12S rRNA gene for the identification of the hosts species. The products were digested with the restriction enzymes, a combination that allows the identification of 60 vertebrate species, comprising 17 bird, 4 reptile and 39 mammalian species. Host DNA was detected in 244 (75%[i] I. ricinus[/i] individuals, with the species being detected and classified for 210 (86% samples. The restriction patterns resulted in the identification of 14 vertebrate species, including 2 species of birds, lizard, badger, rabbit, deer; most of the samples contained DNA from wild boar ([i]Sus scrofa[/i], red fox ([i]Vulpes vulpes[/i], red deer ([i]Cervus elaphus[/i] and roe deer ([i]Capreolus capreolus[/i]. Identification of Borrelia species was based on the flaB gene using nested PCR coupled to RFLP. This method allows the identification of all [i]Borrelia[/i] species transmitted by [i]I. ricinus [/i]in Europe, including [i]B. miyamotoi[/i] and 3 genetic variants of [i]B. garinii[/i]. In the studied isolates, 2 species belonging to [i]B. burgdorferi[/i] sensu lato were identified – B. [i]garinii [/i]and B. [i]afzelii[/i], and B. [i]miyamotoi,[/i] which are related to relapsing fever borreliae.

  7. Evaluation of the clinical implementation of a large-scale online e-learning program on venous blood specimen collection guideline practices.

    Science.gov (United States)

    Willman, Britta; Grankvist, Kjell; Bölenius, Karin

    2018-05-11

    When performed erroneously, the venous blood specimen collection (VBSC) practice steps patient identification, test request management and test tube labeling are at high risk to jeopardize patient safety. VBSC educational programs with the intention to minimize risk of harm to patients are therefore needed. In this study, we evaluate the efficiency of a large-scale online e-learning program on personnel's adherence to VBSC practices and their experience of the e-learning program. An interprofessional team transformed an implemented traditional VBSC education program to an online e-learning program developed to stimulate reflection with focus on the high-risk practice steps. We used questionnaires to evaluate the effect of the e-learning program on personnel's self-reported adherence to VBSC practices compared to questionnaire surveys before and after introduction of the traditional education program. We used content analysis to evaluate the participants free text experience of the VBSC e-learning program. Adherence to the VBSC guideline high-risk practice steps generally increased following the implementation of a traditional educational program followed by an e-learning program. We however found a negative trend over years regarding participation rates and the practice to always send/sign the request form following the introduction of an electronic request system. The participants were in general content with the VBSC e-learning program. Properly designed e-learning programs on VBSC practices supersedes traditional educational programs in usefulness and functionality. Inclusion of questionnaires in the e-learning program is necessary for follow-up of VBSC participant's practices and educational program efficiency.

  8. Room-temperature macromolecular serial crystallography using synchrotron radiation

    Directory of Open Access Journals (Sweden)

    Francesco Stellato

    2014-07-01

    Full Text Available A new approach for collecting data from many hundreds of thousands of microcrystals using X-ray pulses from a free-electron laser has recently been developed. Referred to as serial crystallography, diffraction patterns are recorded at a constant rate as a suspension of protein crystals flows across the path of an X-ray beam. Events that by chance contain single-crystal diffraction patterns are retained, then indexed and merged to form a three-dimensional set of reflection intensities for structure determination. This approach relies upon several innovations: an intense X-ray beam; a fast detector system; a means to rapidly flow a suspension of crystals across the X-ray beam; and the computational infrastructure to process the large volume of data. Originally conceived for radiation-damage-free measurements with ultrafast X-ray pulses, the same methods can be employed with synchrotron radiation. As in powder diffraction, the averaging of thousands of observations per Bragg peak may improve the ratio of signal to noise of low-dose exposures. Here, it is shown that this paradigm can be implemented for room-temperature data collection using synchrotron radiation and exposure times of less than 3 ms. Using lysozyme microcrystals as a model system, over 40 000 single-crystal diffraction patterns were obtained and merged to produce a structural model that could be refined to 2.1 Å resolution. The resulting electron density is in excellent agreement with that obtained using standard X-ray data collection techniques. With further improvements the method is well suited for even shorter exposures at future and upgraded synchrotron radiation facilities that may deliver beams with 1000 times higher brightness than they currently produce.

  9. PORNOGRAFI DALAM SERIAL ANIME ANAK (ANALISIS SEMIOTIKA DALAM SERIAL CRAYON SHIN CHAN

    Directory of Open Access Journals (Sweden)

    - Sangidun

    2017-01-01

    Full Text Available Crayon Shin Chan, a Japanese two-dimension animation series broadcast in one of private Indonesian TVs, is categorized into child’s program since it is broadcast at child’s prime time, Sunday 08.30 a.m. In spite of its broadcast time, this series consist of symbols directed not for children, such as some acts that are not appropriate to be done by children, especially in Indonesia. Moreover, adult symbols of sex are also found in the program. For this reason it will be interesting to analyze it using semiotic analysis. Semiotics is the study of symbol and its meaning which its principle concept is that both signifier and signified consist of symbols and are related to denotation and connotation.   Crayon Shin Chan merupakan serial animasi dua dimensi yang tayang di salah satu stasiun televisi swasta di Indonesia. Ini merupakan produk animasi 2 dimensi yang diimpor dari Jepang. Di Indonesia, serial ini masuk dalam kategori acara anak. Hal ini dapat dilihat dari jam penayangannya yang merupakan waktu prime time bagi anak, yakni pada hari minggu pukul 08.30. Akan tetapi, pada serial ini banyak simbol-simbol yang mengarah pada tayangan yang bukan untuk anak-anak, yakni adeganadegan yang tidak pantas dilakukan oleh anak khususnya di Indonesia. Serta adanya pula simbol-simbol yang mengarah pada tayangan berbau dewasa. Tentu akan menarik jika tayangan ini diteliti menggunakan analisis semiotika. Semiotika sendiri merupakan kajian ilmu mengenai tanda dan makna. Yang pada prinsipnya, konsep penting seperti penanda (signifier dan petanda (signified sama-sama terdiri dari tanda dan terkait dengan denotasi dan konotasi.

  10. Transtornos de personalidade, psicopatia e serial killers Personality disorders, psychopathy and serial killers

    Directory of Open Access Journals (Sweden)

    Hilda C P Morana

    2006-10-01

    Full Text Available OBJETIVO: Apresentar as características básicas dos diversos transtornos específicos de personalidade, mas centrando-se no transtorno de personalidade anti-social, fazendo sua diferenciação com psicopatia. O estudo ainda se propõe a abordar a figura do serial killer, apontando a presença de aspectos psicopáticos no homicídio seriado. MÉTODO: Uma revisão bibliográfica foi feita no sentido de se abordar convergências e divergências entre diversos autores sobre um assunto tão polêmico, sobretudo quanto à viabilidade de tratamento dessa clientela forense. RESULTADOS: Enquanto o transtorno de personalidade anti-social é um diagnóstico médico, pode-se entender o termo "psicopatia", pertencente à esfera psiquiátrico-forense, como um "diagnóstico legal". Não se pode falar ainda de tratamento eficaz para os chamados "serial killers". CONCLUSÃO: Os transtornos de personalidade, especialmente o tipo anti-social, representam ainda hoje um verdadeiro desafio para a psiquiatria forense. O local mais adequado e justo para seus portadores, bem como recomendação homogênea e padronizada de tratamento são questões ainda não respondidas.OBJECTIVE: To illustrate the basic characteristics of several specific personality disorders, focusing mainly in antisocial personality disorder. The differences between antisocial personality disorder and psychopathy are highlighted. Serial killers and its psychopathic aspects are also discussed. METHOD: A bibliographic review was completed in order to outline convergences and divergences among different authors about this controversial issue, especially those concerning the possibility of treatment. RESULTS: While anti-social personality disorder is a medical diagnosis, the term "psychopathy" (which belongs to the sphere of forensic psychiatry may be understood as a "legal diagnosis". It is not still possible to identify an effective treatment for serial killers. CONCLUSION: Personality disorders

  11. Serial forced displacement in American cities, 1916-2010.

    Science.gov (United States)

    Fullilove, Mindy Thompson; Wallace, Rodrick

    2011-06-01

    Serial forced displacement has been defined as the repetitive, coercive upheaval of groups. In this essay, we examine the history of serial forced displacement in American cities due to federal, state, and local government policies. We propose that serial forced displacement sets up a dynamic process that includes an increase in interpersonal and structural violence, an inability to react in a timely fashion to patterns of threat or opportunity, and a cycle of fragmentation as a result of the first two. We present the history of the policies as they affected one urban neighborhood, Pittsburgh's Hill District. We conclude by examining ways in which this problematic process might be addressed.

  12. Serials cataloging at the turn of the century

    CERN Document Server

    Williams, James W

    2014-01-01

    An overview of the research topics and trends that have appeared over the last five years, Serials Cataloging at the Turn of the Century doesn't just tell you that there has been a lot of change--that the information environment is something of a chameleon, always beguiling and slipping out of grasp. Instead, it gives you the plain facts on the specific challenges serials catalogers have been facing and how they're meeting adversity head-on, ready to gain the advantage in the rumble with proliferating information and formats.Comprehensive, resource-packed, and easy-to-digest, Serials Catalogin

  13. The serial message-passing schedule for LDPC decoding algorithms

    Science.gov (United States)

    Liu, Mingshan; Liu, Shanshan; Zhou, Yuan; Jiang, Xue

    2015-12-01

    The conventional message-passing schedule for LDPC decoding algorithms is the so-called flooding schedule. It has the disadvantage that the updated messages cannot be used until next iteration, thus reducing the convergence speed . In this case, the Layered Decoding algorithm (LBP) based on serial message-passing schedule is proposed. In this paper the decoding principle of LBP algorithm is briefly introduced, and then proposed its two improved algorithms, the grouped serial decoding algorithm (Grouped LBP) and the semi-serial decoding algorithm .They can improve LBP algorithm's decoding speed while maintaining a good decoding performance.

  14. Serial CSTR digester configuration for improving biogas production from manure

    DEFF Research Database (Denmark)

    Boe, Kanokwan; Angelidaki, Irini

    2009-01-01

    distribution ratio of 80/20 and 90/10, and total HRT of 15 days. The results showed that the serial CSTR could obtain 11% higher biogas yield compared to the single CSTR. The increased biogas yield in the serial CSTR was mainly from the second reactor, which accounted for 16% and 12% of total biogas yield......A new configuration of manure digesters for improving biogas production has been investigated in laboratory scale. A single thermophilic continuous-flow stirred tank reactor (CSTR) operated with a hydraulic retention time (HRT) of 15 days was compared to a serial CSTR configuration with volume...

  15. Mapping the continuous reciprocal space intensity distribution of X-ray serial crystallography.

    Science.gov (United States)

    Yefanov, Oleksandr; Gati, Cornelius; Bourenkov, Gleb; Kirian, Richard A; White, Thomas A; Spence, John C H; Chapman, Henry N; Barty, Anton

    2014-07-17

    Serial crystallography using X-ray free-electron lasers enables the collection of tens of thousands of measurements from an equal number of individual crystals, each of which can be smaller than 1 µm in size. This manuscript describes an alternative way of handling diffraction data recorded by serial femtosecond crystallography, by mapping the diffracted intensities into three-dimensional reciprocal space rather than integrating each image in two dimensions as in the classical approach. We call this procedure 'three-dimensional merging'. This procedure retains information about asymmetry in Bragg peaks and diffracted intensities between Bragg spots. This intensity distribution can be used to extract reflection intensities for structure determination and opens up novel avenues for post-refinement, while observed intensity between Bragg peaks and peak asymmetry are of potential use in novel direct phasing strategies.

  16. Abutment region dosimetry for serial tomotherapy

    International Nuclear Information System (INIS)

    Low, Daniel A.; Mutic, Sasa; Dempsey, James F.; Markman, Jerry; Goddu, S. Murty; Purdy, James A.

    1999-01-01

    Purpose: A commercial intensity modulated radiation therapy system (Corvus, NOMOS Corp.) is presently used in our clinic to generate optimized dose distributions delivered using a proprietary dynamic multileaf collimator (DMLC) (MIMiC) composed of 20 opposed leaf pairs. On our accelerator (Clinac 600C/D, Varian Associates, Inc.) each MIMiC leaf projects to either 1.00 x 0.84 or 1.00 x 1.70 cm 2 (depending on the treatment plan and termed 1 cm or 2 cm mode, respectively). The MIMiC is used to deliver serial (axial) tomotherapy treatment plans, in which the beam is delivered to a nearly cylindrical volume as the DMLC is rotated about the patient. For longer targets, the patient is moved (indexed) between treatments a distance corresponding to the projected leaf width. The treatment relies on precise indexing and a method was developed to measure the precision of indexing devices. A treatment planning study of the dosimetric effects of incorrect patient indexing and concluded that a dose heterogeneity of 10% mm -1 resulted. Because the results may be sensitive to the dose model accuracy, we conducted a measurement-based investigation of the consequences of incorrect indexing using our accelerator. Although the indexing provides an accurate field abutment along the isocenter, due to beam divergence, hot and cold spots will be produced below and above isocenter, respectively, when less than 300 deg. arcs were used. A preliminary study recently determined that for a 290 deg. rotation in 1 cm mode, 15% cold and 7% hot spots were delivered to 7 cm above and below isocenter, respectively. This study completes the earlier work by investigating the dose heterogeneity as a function of position relative to the axis of rotation, arc length, and leaf width. The influence of random daily patient positioning errors is also investigated. Methods and Materials: Treatment plans were generated using 8.0 cm diameter cylindrical target volumes within a homogeneous rectilinear film

  17. Analyses of cardiac blood cells and serum proteins with regard to cause of death in forensic autopsy cases.

    Science.gov (United States)

    Quan, Li; Ishikawa, Takaki; Michiue, Tomomi; Li, Dong-Ri; Zhao, Dong; Yoshida, Chiemi; Chen, Jian-Hua; Komatsu, Ayumi; Azuma, Yoko; Sakoda, Shigeki; Zhu, Bao-Li; Maeda, Hitoshi

    2009-04-01

    To investigate hematological and serum protein profiles of cadaveric heart blood with regard to the cause of death, serial forensic autopsy cases (n=308, >18 years of age, within 48 h postmortem) were examined. Red blood cells (Rbc), hemoglobin (Hb), platelets (Plt), white blood cells (Wbc), total protein (TP) and albumin (Alb) were examined in bilateral cardiac blood. Blood cell counts, collected after turning the bodies at autopsy, approximated to the clinical values. Postmortem changes were not significant for these markers. In non-head blunt injury cases, Rbc counts, Hb, TP and Alb levels in bilateral cardiac blood were lower in subacute deaths (survival time, 1-12 h) than in acute deaths (survival time hematology analyzer than by using a blood smear test, suggesting Rbc fragmentation caused by deep burns, while increases in Wbc count and decreases in Alb levels were seen for subacute deaths. For asphyxiation, Rbc count, Hb, TP and Alb levels in bilateral cardiac blood were higher than other groups, and TP and Alb levels in the right cardiac blood were higher for hanging than for strangulation. These findings suggest that analyses of blood cells and proteins are useful for investigating the cause of death.

  18. Serial rotatostereography - A new diagnostic method

    International Nuclear Information System (INIS)

    Ottomo, Michinori; Nakanishi, Takeshi.

    1986-01-01

    In the previous study using cine, a cine film stereoprojector showed the adjacent two frames of cine film simultaneously, such as frames 1 and 2, 2 and 3, 3 and 4, and so on, consecutively. Because some intracranial lesions require emergency surgery immediately after angiography, a real time display method of serial rotatostereography was necessary. In order to show the consecutive adjacent two frames of a video disc simultaneously, using the same method as with the cine stereoprojector, a video disc recorder (VDR) (VM-1000M) and two video memories (Image Σ) were required. This VDR has the ability of advancing, stopping, and reversing the display of memories. A control unit was manufactured in order to display these memories advancing and reversing continuously. As a result of this continuous semirotation stereo display, the anteroposterior projection was reversed, showing the posteroanterior view during ''reversing mode''. Thus a lead relay circuit was manufactured to prevent this phenomenon. Recording was done using a memory disc recorder (FOM 2200F), which has the ability of recording 10,000 frames per disc. Each frame can also be recorded on imaging film using O · X Multi Camera 400X. Finally, stereoscopic views of cerebral circulation, using a single injection of contrast media and rapid rotation of the gantry, were obtained using two cathode-ray tubes (CRTs) and a stereoviewer (Continuous Semi-rotation Classical Stereo Display Method). Stereoscopic views were also obtained using a single CRT, which displayed the images in a semirotating fashion similar to a oscillating fan head (Continuous Semi-rotation New Stereo Display Method). (J.P.N.)

  19. The investigation of in-vivo measurement of individual renal blood perfusion, effective renal plasma flow and quantitation of renogram and 15 min bladder collection percentage

    International Nuclear Information System (INIS)

    Huang Kangchu

    1991-01-01

    25 normals and 43 renal diseases were examined by the RBF-I multifunctioning renography. The result showed that the determination of ERPF has no difference between blood sampling and noin-blood sampling method, and actually the lattrer can replace the former one. Above method can be also used for the measurement of the individual renal blood perfusion, the quantitation of renogram and the 15 min bladder coolection percentage at the same time. Thereby it provides more complete diagnostic information for the renal vascular diseases, renal pancren chymations and other urologic diseases

  20. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    Science.gov (United States)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Wu, Chun-Han; Lin, Yu-Cheng

    2014-09-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood.

  1. Using the developed cross-flow filtration chip for collecting blood plasma under high flow rate condition and applying the immunoglobulin E detection

    International Nuclear Information System (INIS)

    Yeh, Chia-Hsien; Hung, Chia-Wei; Lin, Yu-Cheng; Wu, Chun-Han

    2014-01-01

    This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood. (paper)

  2. Attractive Serial Dependence in the Absence of an Explicit Task.

    Science.gov (United States)

    Fornaciai, Michele; Park, Joonkoo

    2018-03-01

    Attractive serial dependence refers to an adaptive change in the representation of sensory information, whereby a current stimulus appears to be similar to a previous one. The nature of this phenomenon is controversial, however, as serial dependence could arise from biased perceptual representations or from biased traces of working memory representation at a decisional stage. Here, we demonstrated a neural signature of serial dependence in numerosity perception emerging early in the visual processing stream even in the absence of an explicit task. Furthermore, a psychophysical experiment revealed that numerosity perception is biased by a previously presented stimulus in an attractive way, not by repulsive adaptation. These results suggest that serial dependence is a perceptual phenomenon starting from early levels of visual processing and occurring independently from a decision process, which is consistent with the view that these biases smooth out noise from neural signals to establish perceptual continuity.

  3. Fast Grasp Contact Computation for a Serial Robot

    Science.gov (United States)

    Shi, Jianying (Inventor); Hargrave, Brian (Inventor); Diftler, Myron A. (Inventor)

    2015-01-01

    A system includes a controller and a serial robot having links that are interconnected by a joint, wherein the robot can grasp a three-dimensional (3D) object in response to a commanded grasp pose. The controller receives input information, including the commanded grasp pose, a first set of information describing the kinematics of the robot, and a second set of information describing the position of the object to be grasped. The controller also calculates, in a two-dimensional (2D) plane, a set of contact points between the serial robot and a surface of the 3D object needed for the serial robot to achieve the commanded grasp pose. A required joint angle is then calculated in the 2D plane between the pair of links using the set of contact points. A control action is then executed with respect to the motion of the serial robot using the required joint angle.

  4. BRAIN Journal - Some Considerations on Seriality and Synchronicity

    OpenAIRE

    Elena Nechita

    2017-01-01

    ABSTRACT This paper presents an overview of the results that have been obtained lately on seriality and synchronicity and their link, in the light of the new theories and within the frame of complexity science.

  5. Serials Management In Polytechnic Libraries in Nigeria: A ...

    African Journals Online (AJOL)

    Serials Management In Polytechnic Libraries in Nigeria: A Comparative Study of Kaduna Polytechnic And Yaba College of Technology Libraries. ... Samaru Journal of Information Studies. Journal Home · ABOUT THIS JOURNAL · Advanced ...

  6. Energy information data base. Serial titles, February 1978--June 1979

    International Nuclear Information System (INIS)

    1979-06-01

    This supplement contains changes and additions to TID-4579-R10 (the authority list for serial titles used by TIC), and is intended to be used with that publication. Supplements are cumulative until another revision is issued

  7. Fault tolerance based on serial communication of FPGA

    International Nuclear Information System (INIS)

    Peng Jing; Fang Zongliang; Xu Quanzhou; Hu Jiewei; Ma Guizhen

    2012-01-01

    There maybe appear mistake in serial communication. This paper was described the intellectual detector of γ dose ratemeter communication with FPGA. The software of FPGA designed the code about fault tolerance, prevented mistake effectively. (authors)

  8. Using Behavior Sequence Analysis to Map Serial Killers' Life Histories.

    Science.gov (United States)

    Keatley, David A; Golightly, Hayley; Shephard, Rebecca; Yaksic, Enzo; Reid, Sasha

    2018-03-01

    The aim of the current research was to provide a novel method for mapping the developmental sequences of serial killers' life histories. An in-depth biographical account of serial killers' lives, from birth through to conviction, was gained and analyzed using Behavior Sequence Analysis. The analyses highlight similarities in behavioral events across the serial killers' lives, indicating not only which risk factors occur, but the temporal order of these factors. Results focused on early childhood environment, indicating the role of parental abuse; behaviors and events surrounding criminal histories of serial killers, showing that many had previous convictions and were known to police for other crimes; behaviors surrounding their murders, highlighting differences in victim choice and modus operandi; and, finally, trial pleas and convictions. The present research, therefore, provides a novel approach to synthesizing large volumes of data on criminals and presenting results in accessible, understandable outcomes.

  9. How Do We Write about Performance in Serial Television?

    OpenAIRE

    Elliott Logan

    2015-01-01

    Television studies has produced few sustained analyses of performance in serial television. Yet film studies scholarship has shown how attending to the integration of performances with other aspects of film style is crucial to the interpretation and appreciation of expression and meaning in filmed narrative fictions. However, as a particle form of filmed serial narrative, series television raises a number of questions about performance that will not necessarily be satisfyingly addressed by th...

  10. Stem cell collection in unmanipulated HLA-haploidentical/mismatched related transplantation with combined granulocyte-colony stimulating factor-mobilised blood and bone marrow for patients with haematologic malignancies: the impact of donor characteristics and procedural settings.

    Science.gov (United States)

    Zhang, C; Chen, X-H; Zhang, X; Gao, L; Gao, L; Kong, P-Y; Peng, X-G; Sun, A-H; Gong, Y; Zeng, D-F; Wang, Q-Y

    2010-06-01

    Unmanipulated haploidentical/mismatched related transplantation with combined granulocyte-colony stimulating factor-mobilised peripheral blood stem cells (G-PBSCs) and granulocyte-colony stimulating factor-mobilised bone marrow (G-BM) has been developed as an alternative transplantation strategy for patients with haematologic malignancies. However, little information is available about the factors predicting the outcome of peripheral blood stem cell (PBSC) collection and bone marrow (BM) harvest in this transplantation. The effects of donor characteristics and procedure factors on CD34(+) cell yield were investigated. A total of 104 related healthy donors received granulocyte-colony stimulating factor (G-CSF) followed by PBSC collection and BM harvest. Male donors had significantly higher yields compared with female donors. In multiple regression analysis for peripheral blood collection, age and flow rate were negatively correlated with cell yield, whereas body mass index, pre-aphaeresis white blood cell (WBC) and circulating immature cell (CIC) counts were positively correlated with cell yields. For BM harvest, age was negatively correlated with cell yields, whereas pre-BM collection CIC counts were positively correlated with cell yield. All donors achieved the final product of >or=6 x10(6) kg(-1) recipient body weight. This transplantation strategy has been shown to be a feasible approach with acceptable outcomes in stem cell collection for patients who received HLA-haploidentical/mismatched transplantation with combined G-PBSCs and G-BM. In donors with multiple high-risk characteristics for poor aphaeresis CD34(+) cell yield, BM was an alternative source.

  11. Three more semantic serial position functions and a SIMPLE explanation.

    Science.gov (United States)

    Kelley, Matthew R; Neath, Ian; Surprenant, Aimée M

    2013-05-01

    There are innumerable demonstrations of serial position functions-with characteristic primacy and recency effects-in episodic tasks, but there are only a handful of such demonstrations in semantic memory tasks, and those demonstrations have used only two types of stimuli. Here, we provide three more examples of serial position functions when recalling from semantic memory. Participants were asked to reconstruct the order of (1) two cartoon theme song lyrics, (2) the seven Harry Potter books, and (3) two sets of movies, and all three demonstrations yielded conventional-looking serial position functions with primacy and recency effects. The data were well-fit by SIMPLE, a local distinctiveness model of memory that was originally designed to account for serial position effects in short- and long-term episodic memory. According to SIMPLE, serial position functions in both episodic and semantic memory tasks arise from the same type of processing: Items that are more separated from their close neighbors in psychological space at the time of recall will be better remembered. We argue that currently available evidence suggests that serial position functions observed when recalling items that are presumably in semantic memory arise because of the same processes as those observed when recalling items that are presumably in episodic memory.

  12. How Do We Write about Performance in Serial Television?

    Directory of Open Access Journals (Sweden)

    Elliott Logan

    2015-05-01

    Full Text Available Television studies has produced few sustained analyses of performance in serial television. Yet film studies scholarship has shown how attending to the integration of performances with other aspects of film style is crucial to the interpretation and appreciation of expression and meaning in filmed narrative fictions. However, as a particle form of filmed serial narrative, series television raises a number of questions about performance that will not necessarily be satisfyingly addressed by the direct adoption and application of approaches to writing about performance that have been honed in regard to film. How, then, do we write about performance in television serials in ways that recognise and accommodate the form’s relationship to film, while at the same time appropriately acknowledging and responding to long-form television’s serial status? To examine the difficulties and opportunities of approaching performance in serial television this way, the article conducts close readings of various pieces of television studies writing on performance, by scholars such as Jason Mittell, Sue Turnbull, George Toles, and Steven Peacock. Their work brings into view film and television’s points of common relation, and the distinctive challenges, achievements, and rewards of appreciating the best television serials, and the performances in them.

  13. Serial millisecond crystallography of membrane and soluble protein microcrystals using synchrotron radiation.

    Science.gov (United States)

    Martin-Garcia, Jose M; Conrad, Chelsie E; Nelson, Garrett; Stander, Natasha; Zatsepin, Nadia A; Zook, James; Zhu, Lan; Geiger, James; Chun, Eugene; Kissick, David; Hilgart, Mark C; Ogata, Craig; Ishchenko, Andrii; Nagaratnam, Nirupa; Roy-Chowdhury, Shatabdi; Coe, Jesse; Subramanian, Ganesh; Schaffer, Alexander; James, Daniel; Ketwala, Gihan; Venugopalan, Nagarajan; Xu, Shenglan; Corcoran, Stephen; Ferguson, Dale; Weierstall, Uwe; Spence, John C H; Cherezov, Vadim; Fromme, Petra; Fischetti, Robert F; Liu, Wei

    2017-07-01

    Crystal structure determination of biological macromolecules using the novel technique of serial femtosecond crystallography (SFX) is severely limited by the scarcity of X-ray free-electron laser (XFEL) sources. However, recent and future upgrades render microfocus beamlines at synchrotron-radiation sources suitable for room-temperature serial crystallography data collection also. Owing to the longer exposure times that are needed at synchrotrons, serial data collection is termed serial millisecond crystallography (SMX). As a result, the number of SMX experiments is growing rapidly, with a dozen experiments reported so far. Here, the first high-viscosity injector-based SMX experiments carried out at a US synchrotron source, the Advanced Photon Source (APS), are reported. Microcrystals (5-20 µm) of a wide variety of proteins, including lysozyme, thaumatin, phycocyanin, the human A 2A adenosine receptor (A 2A AR), the soluble fragment of the membrane lipoprotein Flpp3 and proteinase K, were screened. Crystals suspended in lipidic cubic phase (LCP) or a high-molecular-weight poly(ethylene oxide) (PEO; molecular weight 8 000 000) were delivered to the beam using a high-viscosity injector. In-house data-reduction (hit-finding) software developed at APS as well as the SFX data-reduction and analysis software suites Cheetah and CrystFEL enabled efficient on-site SMX data monitoring, reduction and processing. Complete data sets were collected for A 2A AR, phycocyanin, Flpp3, proteinase K and lysozyme, and the structures of A 2A AR, phycocyanin, proteinase K and lysozyme were determined at 3.2, 3.1, 2.65 and 2.05 Å resolution, respectively. The data demonstrate the feasibility of serial millisecond crystallography from 5-20 µm crystals using a high-viscosity injector at APS. The resolution of the crystal structures obtained in this study was dictated by the current flux density and crystal size, but upcoming developments in beamline optics and the planned APS

  14. Serial millisecond crystallography of membrane and soluble protein microcrystals using synchrotron radiation

    Directory of Open Access Journals (Sweden)

    Jose M. Martin-Garcia

    2017-07-01

    Full Text Available Crystal structure determination of biological macromolecules using the novel technique of serial femtosecond crystallography (SFX is severely limited by the scarcity of X-ray free-electron laser (XFEL sources. However, recent and future upgrades render microfocus beamlines at synchrotron-radiation sources suitable for room-temperature serial crystallography data collection also. Owing to the longer exposure times that are needed at synchrotrons, serial data collection is termed serial millisecond crystallography (SMX. As a result, the number of SMX experiments is growing rapidly, with a dozen experiments reported so far. Here, the first high-viscosity injector-based SMX experiments carried out at a US synchrotron source, the Advanced Photon Source (APS, are reported. Microcrystals (5–20 µm of a wide variety of proteins, including lysozyme, thaumatin, phycocyanin, the human A2A adenosine receptor (A2AAR, the soluble fragment of the membrane lipoprotein Flpp3 and proteinase K, were screened. Crystals suspended in lipidic cubic phase (LCP or a high-molecular-weight poly(ethylene oxide (PEO; molecular weight 8 000 000 were delivered to the beam using a high-viscosity injector. In-house data-reduction (hit-finding software developed at APS as well as the SFX data-reduction and analysis software suites Cheetah and CrystFEL enabled efficient on-site SMX data monitoring, reduction and processing. Complete data sets were collected for A2AAR, phycocyanin, Flpp3, proteinase K and lysozyme, and the structures of A2AAR, phycocyanin, proteinase K and lysozyme were determined at 3.2, 3.1, 2.65 and 2.05 Å resolution, respectively. The data demonstrate the feasibility of serial millisecond crystallography from 5–20 µm crystals using a high-viscosity injector at APS. The resolution of the crystal structures obtained in this study was dictated by the current flux density and crystal size, but upcoming developments in beamline optics and the

  15. Evaluation of droplet digital PCR for quantification of residual leucocytes in red blood cell concentrates.

    Science.gov (United States)

    Doescher, A; Loges, U; Petershofen, E K; Müller, T H

    2017-11-01

    Enumeration of residual white blood cells in leucoreduced blood components is essential part of quality control. Digital PCR has substantially facilitated quantitative PCR and was thus evaluated for measurements of leucocytes. Target for quantification of leucocytes by digital droplet PCR was the blood group gene RHCE. The SPEF1 gene was added as internal control for the entire assay starting with automated DNA extraction. The sensitivity of the method was determined by serial dilutions of standard samples. Quality control samples were analysed within 24 h, 7 days and 6 months after collection. Routine samples from leucodepleted red blood cell concentrates (n = 150) were evaluated in parallel by flow-cytometry (LeucoCount) and by digital PCR. Digital PCR reliably detected at least 0·4 leucocytes per assay. The mean difference between PCR and flow-cytometric results from 150 units was -0·01 (±1·0). DNA samples were stable for up to at least six months. PCR measurement of leucocytes in samples from plasma and platelet concentrates also provided valid results in a pilot study. Droplet digital PCR to enumerate leucocytes offers an alternative for quality control of leucoreduced blood products. Sensitivity, specificity and reproducibility are comparable to flow-cytometry. The option to collect samples over an extended period of time and the automatization introduce attractive features for routine quality control. © 2017 International Society of Blood Transfusion.

  16. The use of perioperative serial blood lactate levels, the APACHE II and the postoperative MELD as predictors of early mortality after liver transplantation O uso da dosagem seriada do lactato sérico no perioperatório, do APACHE II e do MELD pós-operatório como preditores de mortalidade precoce após transplante hepático

    Directory of Open Access Journals (Sweden)

    Anibal Basile-Filho

    2011-12-01

    Full Text Available PURPOSE: To evaluate the accuracy of different parameters in predicting early (one-month mortality of patients submitted to orthotopic liver transplantation (OLT. METHODS: This is a retrospective study of forty-four patients (38 males and 10 females, mean age of 52.2 ± 8.9 years admitted to the Intensive Care Unit of a tertiary hospital. Serial lactate blood levels, APACHE II, MELD post-OLT, creatinine, bilirubin and INR parameters were analyzed by receiver-operator characteristic (ROC curves as evidenced by the area under the curve (AUC. The level of significance was set at 0.05. RESULTS: The mortality of OLT patients within one month was 17.3%. Differences in blood lactate levels became statistically significant between survivors and nonsurvivors at the end of the surgery (pOBJETIVO: Avaliar qual parâmetro é o mais eficiente na predição de mortalidade precoce (um mês de pacientes submetidos a transplante ortotópico de fígado (OLT. MÉTODOS: Estudo retrospectivo em cinqüenta e oito pacientes adultos (44 homens e 14 mulheres, com uma idade média de 51,7 ± 10,1 anos admitidos na Unidade de Terapia Intensiva de um hospital terciário. Os parâmetros como a dosagem seriada de lactato no sangue, APACHE II, MELD pós-OLT, creatinina, bilirrubina e INR foram analisados por curvas ROC (Receiver-operator characteristic, evidenciado pela área abaixo da curva (AUC. O nível de significância foi definido em 0,05. RESULTADOS: A mortalidade dos pacientes OLT em até um mês foi de 17,3%. As diferenças no nível de lactato no sangue tornaram-se estatisticamente significantes entre sobreviventes e não sobreviventes no final da cirurgia (p < 0,05. A AUC foi de 0,726 (95%CI = 0,593-0,835 para APACHE II (p = 0,02; 0,770 (95%CI = 0,596-0,849 para o lactato sérico (L7-L8 (p = 0,03; 0,814 (95%CI = 0,690-0,904 para MELD post-OLT (p < 0,01; 0,550 (95%CI = 0,414-0,651 de creatinina (p = 0,64; 0,705 (95%CI = 0,571-0,818 de bilirrubina (p = 0,05 e 0

  17. “It’s Always the Same, and It’s Always Different” Mythologisation and the Serial Killer in Henry: Portrait of a Serial Killer.

    OpenAIRE

    Smyth, David A.

    2015-01-01

    Serial killers are important in American horror because of their ability to exist between ‘myth’ and ‘reality’. The serial killer is one of the most important American myths, but it is one firmly rooted in real life: unlike Paul Bunyan or Superman, serial killers do exist. This essay examines the relationship between the ‘myth’ and the ‘reality’ of serial killers, and the complex relationship between the American public and the serial killer, using Henry: Portrait of a Serial K...

  18. Determine the prevalence of Brucella spp. and Leptospira spp. in blood samples by multiplex polymerase chain reaction collected from cattle, sheep and goats in herds located in provinces of Iran

    Directory of Open Access Journals (Sweden)

    Faham Khamesipour

    2014-05-01

    Full Text Available Leptospirosis and brucellosis are common zoonosis that affect many species of mammals mostly causing economical losses. Further, very important fact is huge danger for human and animal health around the world. The purpose of the study is to determine the prevalence of Brucella spp. and Leptospira spp. using multiplex polymerase chain reaction (mPCR method, in blood samples collected from cattle, sheep and goats. In this study, a total number of 250 blood samples (5 cc of blood with ethilen diamin tetra asetic acid were collected randomly from 100 cattle, 80 sheep and 70 goats located on 6 herds in Chaharmahal Va Bakhtiari and Esfahan provinces, Iran. After DNA extraction and setting of mPCR for Brucella spp. and Leptospira spp. mPCR products were screened. The DNA of these microorganisms was detected by multiplex PCR from 31 and 21 out of 100 cattle, respectively. Four of 70 goat’s blood samples from goat breeding farms were positive for Leptospira spp. and 11 were positive for Brucella spp. Out of 80 sheep blood samples 23 were positive for Brucella spp. and 14 for Leptospira spp. The results of the present study show ruminant as an important reservoir for transmission of these zoonotic diseases to humans in Iran. mPCR has the ability to concurrently detect both Brucella and Leptospira species from blood samples of ruminants. The convenience and the possibility of detection of both bacteria at a time, strongly support the use of this mPCR for routine diagnostics.

  19. Detection and three-dimensional reconstruction of a vascular network from serial sections

    Energy Technology Data Exchange (ETDEWEB)

    Ip, H H.S.

    1983-07-01

    The process of three-dimensional reconstruction from serial sections includes aligning adjacent sections, segmenting the desired objects and constructing a computer internal model of the reconstructed object. Computational methodologies taking advantage of the parallel processing facilities of CLIP4 are presented for automating these tasks. The author is interested in the detailed structure of the carotid body which is a highly vascularized organ with the largest blood flow rate of any tissue in the body (Biscoe (1971), Seidl (1975), Lubbers et al. (1977), Clarke and Daly (1982)). It plays an important role in monitoring the chemical composition of arterial blood (p(o/sub 2/), p(co/sub 2/), ph). The aim of the investigation in the paper is to reconstruct the total vasculature of the organ and to make an analytical study of the geometrical configuration of its vessels. 15 references.

  20. Challenges of microtome‐based serial block‐face scanning electron microscopy in neuroscience

    Science.gov (United States)

    WANNER, A. A.; KIRSCHMANN, M. A.

    2015-01-01

    Summary Serial block‐face scanning electron microscopy (SBEM) is becoming increasingly popular for a wide range of applications in many disciplines from biology to material sciences. This review focuses on applications for circuit reconstruction in neuroscience, which is one of the major driving forces advancing SBEM. Neuronal circuit reconstruction poses exceptional challenges to volume EM in terms of resolution, field of view, acquisition time and sample preparation. Mapping the connections between neurons in the brain is crucial for understanding information flow and information processing in the brain. However, information on the connectivity between hundreds or even thousands of neurons densely packed in neuronal microcircuits is still largely missing. Volume EM techniques such as serial section TEM, automated tape‐collecting ultramicrotome, focused ion‐beam scanning electron microscopy and SBEM (microtome serial block‐face scanning electron microscopy) are the techniques that provide sufficient resolution to resolve ultrastructural details such as synapses and provides sufficient field of view for dense reconstruction of neuronal circuits. While volume EM techniques are advancing, they are generating large data sets on the terabyte scale that require new image processing workflows and analysis tools. In this review, we present the recent advances in SBEM for circuit reconstruction in neuroscience and an overview of existing image processing and analysis pipelines. PMID:25907464

  1. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  2. The cortisol awakening response is associated with performance of a serial sequence reaction time task.

    Science.gov (United States)

    Hodyl, Nicolette A; Schneider, Luke; Vallence, Ann-Maree; Clow, Angela; Ridding, Michael C; Pitcher, Julia B

    2016-02-01

    There is emerging evidence of a relationship between the cortisol awakening response (CAR) and the neural mechanisms underlying learning and memory. The aim of this study was to determine whether the CAR is associated with acquisition, retention and overnight consolidation or improvement of a serial sequence reaction time task. Salivary samples were collected at 0, 15, 30 and 45 min after awakening in 39 healthy adults on 2 consecutive days. The serial sequence reaction time task was repeated each afternoon. Participants completed the perceived stress scale and provided salivary samples prior to testing for cortisol assessment. While the magnitude of the CAR (Z score) was not associated with either baseline performance or the timed improvement during task acquisition of the serial sequence task, a positive correlation was observed with reaction times during the stable performance phase on day 1 (r=0.373, p=0.019). Residuals derived from the relationship between baseline and stable phase reaction times on day 1 were used as a surrogate for the degree of learning: these residuals were also correlated with the CAR mean increase on day 1 (r=0.357, p=0.048). Task performance on day 2 was not associated with the CAR obtained on this same day. No association was observed between the perceived stress score, cortisol at testing or task performance. These data indicate that a smaller CAR in healthy adults is associated with a greater degree of learning and faster performance of a serial sequence reaction time task. These results support recognition of the CAR as an important factor contributing to cognitive performance throughout the day. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  4. Blood Types

    Science.gov (United States)

    ... blood, safe blood transfusions depend on careful blood typing and cross-matching. There are four major blood ... cause exceptions to the above patterns. ABO blood typing is not sufficient to prove or disprove paternity ...

  5. Hemispatial neglect and serial order in verbal working memory.

    Science.gov (United States)

    Antoine, Sophie; Ranzini, Mariagrazia; van Dijck, Jean-Philippe; Slama, Hichem; Bonato, Mario; Tousch, Ann; Dewulf, Myrtille; Bier, Jean-Christophe; Gevers, Wim

    2018-01-09

    Working memory refers to our ability to actively maintain and process a limited amount of information during a brief period of time. Often, not only the information itself but also its serial order is crucial for good task performance. It was recently proposed that serial order is grounded in spatial cognition. Here, we compared performance of a group of right hemisphere-damaged patients with hemispatial neglect to healthy controls in verbal working memory tasks. Participants memorized sequences of consonants at span level and had to judge whether a target consonant belonged to the memorized sequence (item task) or whether a pair of consonants were presented in the same order as in the memorized sequence (order task). In line with this idea that serial order is grounded in spatial cognition, we found that neglect patients made significantly more errors in the order task than in the item task compared to healthy controls. Furthermore, this deficit seemed functionally related to neglect severity and was more frequently observed following right posterior brain damage. Interestingly, this specific impairment for serial order in verbal working memory was not lateralized. We advance the hypotheses of a potential contribution to the deficit of serial order in neglect patients of either or both (1) reduced spatial working memory capacity that enables to keep track of the spatial codes that provide memorized items with a positional context, (2) a spatial compression of these codes in the intact representational space. © 2018 The British Psychological Society.

  6. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  7. The relationship between serial sexual murder and autoerotic asphyxiation.

    Science.gov (United States)

    Myers, Wade C; Bukhanovskiy, Alexandr; Justen, Elle; Morton, Robert J; Tilley, John; Adams, Kenneth; Vandagriff, Virgil L; Hazelwood, Robert R

    2008-04-07

    This case series documents and examines the association between autoerotic asphyxiation, sadomasochism, and serial sexual murderers. Autoerotic asphyxiation, along with other paraphilias found in this population, is reviewed. Five cases of serial sexual killers who engaged in autoerotic asphyxiation were identified worldwide: four from the United States and one from Russia. Case reports for each are provided. All (100%) were found to have sexual sadism in addition to autoerotic asphyxiation. Furthermore, two (40%) had bondage fetishism, and two (40%) had transvestic fetishism, consistent with these paraphilias co-occurring in those with autoerotic asphyxiation. Overall the group averaged 4.0 lifetime paraphilias. Some possible relationships were observed between the offenders' paraphilic orientation and their modus operandi, e.g., all of these serial killers strangled victims-suggesting an association between their sadistic and asphyxiative paraphilic interests. The overlap of seemingly polar opposite paraphilias in this sample--sexual sadism and autoerotic asphyxiation--is explored from a historical and clinical perspective. Multiple commonalities shared between these five offenders and serial sexual murderers in general are addressed. A primary limitation of this study is its small sample size and empirical basis; the results may not be generalizable beyond the sample. The findings from this study support the supposition that crime scene behaviors often reflect paraphilic disturbances in those who commit serial sexual homicides.

  8. Increased blood clearance rate of indium-111 oxine-labeled autologous CD4+ blood cells in untreated patients with Hodgkin's disease

    International Nuclear Information System (INIS)

    Grimfors, G.; Holm, G.; Mellstedt, H.; Schnell, P.O.; Tullgren, O.; Bjoerkholm, M.

    1990-01-01

    Untreated patients with Hodgkin's disease (HD) have a blood T-lymphocytopenia mainly caused by a reduction of the CD4+ subset. Indirect support for a sequestration of T cells in the spleen and tumor-involved lymphoid tissue has accumulated. To test the hypothesis that the blood CD4 T-lymphocytopenia in patients with HD is caused by an altered lymphocyte traffic, 12 untreated HD patients and five in complete clinical remission (CCR) were studied. Blood lymphocytes were collected by leukapheresis and gradient centrifugation, and were further purified by an adherence step. The cells were labeled with indium-111 oxine and reinfused intravenously into the patient. The radioactivity of CD4+ and CD8+ blood lymphocytes separated by immunoabsorption was measured from serial blood samples. CD4+ cells were eliminated more rapidly in untreated patients than patients in CCR. Repeated gamma camera imaging after autotransfusion of indium-111 oxine labeled cells demonstrated an accumulation of radioactivity in tumor-involved tissue of untreated patients. These findings support the concept of an enhanced elimination of CD4+ cells in patients with active HD that may contribute to the observed blood T-lymphocytopenia and may reflect a biologic response to the tumor

  9. Faculty Decisions on Serials Subscriptions Differ Significantly from Decisions Predicted by a Bibliometric Tool.

    Directory of Open Access Journals (Sweden)

    Sue F. Phelps

    2016-03-01

    Full Text Available Objective – To compare faculty choices of serials subscription cancellations to the scores of a bibliometric tool. Design – Natural experiment. Data was collected about faculty valuations of serials. The California Digital Library Weighted Value Algorithm (CDL-WVA was used to measure the value of journals to a particular library. These two sets of scores were then compared. Setting – A public research university in the United States of America. Subjects – Teaching and research faculty, as well as serials data. Methods – Experimental methodology was used to compare faculty valuations of serials (based on their journal cancellation choices to bibliometric valuations of the same journal titles (determined by CDL-WVA scores to identify the match rate between the faculty choices and the bibliographic data. Faculty were asked to select titles to cancel that totaled approximately 30% of the budget for their disciplinary fund code. This “keep” or “cancel” choice was the binary variable for the study. Usage data was gathered for articles downloaded through the link resolver for titles in each disciplinary dataset, and the CDL-WVA scores were determined for each journal title based on utility, quality, and cost effectiveness. Titles within each dataset were ranked highest to lowest using the CDL-WVA scores within each fund code, and then by subscription cost for titles with the same CDL-WVA score. The journal titles selected for comparison were those that ranked above the approximate 30% of titles chosen for cancellation by faculty and CDL-WVA scores. Researchers estimated an odds ratio of faculty choosing to keep a title and a CDL-WVA score that indicated the title should be kept. The p-value for that result was less than 0.0001, indicating that there was a negligible probability that the results were by chance. They also applied logistic regression to quantify the association between the numeric score of CDL-WVA and the binary variable

  10. Accuracy of Transcutaneous CO2 Values Compared With Arterial and Capillary Blood Gases.

    Science.gov (United States)

    Lambert, Laura L; Baldwin, Melissa B; Gonzalez, Cruz Velasco; Lowe, Gary R; Willis, J Randy

    2018-05-08

    Transcutaneous monitors are utilized to monitor a patient's respiratory status. Some patients have similar values when comparing transcutaneous carbon dioxide ( P tcCO 2 ) values with blood gas analysis, whereas others show extreme variability. A retrospective review of data was performed to determine how accurately P tcCO 2 correlated with CO 2 values obtained by arterial blood gas (ABG) or capillary blood gas. To determine whether P tcCO 2 values correlated with ABG or capillary blood gas values, subjects' records were retrospectively reviewed. Data collected included the P tcCO 2 value at the time of blood gas procurement and the ABG or capillary blood gas P CO 2 value. Agreement of pairs of methods (ABG vs P tcCO 2 and capillary blood gas vs P tcCO 2 ) was assessed with the Bland-Altman approach with limits of agreement estimated with a mixed model to account for serial measurements per subject. A total of 912 pairs of ABG/ P tcCO 2 values on 54 subjects and 307 pairs of capillary blood gas/ P tcCO 2 values on 34 subjects were analyzed. The P CO 2 range for ABG was 24-106 mm Hg, and P tcCO 2 values were 27-133 mm Hg. The P CO 2 range for capillary blood gas was 29-108 mm Hg, and P tcCO 2 values were 30-103 mm Hg. For ABG/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.82, 95% CI was 0.80-0.84, and P was <.001. For capillary blood gas/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.77, 95% CI was 0.72-0.81, and P was <.001. For ABG/ P tcCO 2 , the estimated difference ± SD was -6.79 t± 7.62 mm Hg, and limits of agreement were -22.03 to 8.45. For capillary blood gas/ P tcCO 2 , the estimated difference ± SD was -1.61 ± 7.64 mm Hg, and limits of agreement were -16.88 to 13.66. The repeatability coefficient was about 30 mm Hg. Based on these data, capillary blood gas comparisons showed less variation and a slightly lower correlation with P tcCO 2 than did ABG comparisons. After accounting for serial measurements per patient

  11. Piezoelectric micromotor based on the structure of serial bending arms.

    Science.gov (United States)

    Tong, Jianhua; Cui, Tianhong; Shao, Peige; Wang, Liding

    2003-09-01

    This paper presents a new piezoelectric micromotor based on the structure of serial bending arms. Serial bending arms are composed of two piezoelectric bimorphs with one end fixed and the other end free, driven by two signals of a biased square wave with a phase difference of pi/2. The free end of a cantilever arm will move along an elliptic orbit so that the cantilever is used to drive a cylinder rotor. The rotor's end surface contacts the free end of the cantilever, resulting in the rotor's rotation. There are six serial bending arms anchored on the base. The driving mechanism of the micromotor is proposed and analyzed. A new micromotor prototype, 5 mm in diameter, has been fabricated and characterized. The maximum rotational speed reaches 325 rpm, and the output torque is about 36.5 microNm.

  12. Numerical discrepancy between serial and MPI parallel computations

    Directory of Open Access Journals (Sweden)

    Sang Bong Lee

    2016-09-01

    Full Text Available Numerical simulations of 1D Burgers equation and 2D sloshing problem were carried out to study numerical discrepancy between serial and parallel computations. The numerical domain was decomposed into 2 and 4 subdomains for parallel computations with message passing interface. The numerical solution of Burgers equation disclosed that fully explicit boundary conditions used on subdomains of parallel computation was responsible for the numerical discrepancy of transient solution between serial and parallel computations. Two dimensional sloshing problems in a rectangular domain were solved using OpenFOAM. After a lapse of initial transient time sloshing patterns of water were significantly different in serial and parallel computations although the same numerical conditions were given. Based on the histograms of pressure measured at two points near the wall the statistical characteristics of numerical solution was not affected by the number of subdomains as much as the transient solution was dependent on the number of subdomains.

  13. A combination strategy for tracking the serial criminal

    Science.gov (United States)

    He, Chuan; Zhang, Yuan-Biao; Wan, Jiadi; Yu, Wenjing

    2010-08-01

    We build a Geographic Profiling Model to generate the criminal's geographical profile, by combining two complementary strategies: the Spatial Distribution Strategy and the Probability Distance Strategy. In the first strategy, we designate the mean of all the known crime sites as the anchor point, and build a Standard Deviational Ellipse Model, considering the effect of landscape. In the second strategy, we take many factors such as the buffer zone and distance decay theory into consideration and calculate the probability of the offender's residence in a certain area by using the Bayesian Theorem and the Rossmo Algorithm. Then, we combine the result of two strategies and get three search areas suit different conditions of the police to track the serial criminal. Apply the model to the English serial killer Peter Sutcliffe's case, the calculation result shows that the model can effectively be used to track serial criminal.

  14. S3-1: The Serial Dependence of Visual Perception

    Directory of Open Access Journals (Sweden)

    David Whitney

    2012-10-01

    Full Text Available In our moment-to-moment perceptual experience, visual scenes can change, but objects rarely spontaneously come into or out of existence. The visual system may therefore delicately balance the need to optimize sensitivity to image changes (e.g., by adapting to changes in color, orientation, object identity, etc with the desire to represent the temporal continuity of objects—the likelihood that objects perceived at this moment tend to exist in subsequent moments. One way that the visual system may promote such stability is through the introduction of serial dependence to visual perception: by biasing the current percept toward what was seen at previous moments, the brain could compensate for variability in visual input that might otherwise disrupt perceptual continuity. Here, in two sets of experiments, we tested for serial dependence in visual perception of orientation and facial expression. We found that on a given trial, a subject's perception of the orientation of a grating reflected not only the currently viewed stimulus, but also a systematic attraction toward the orientations of the previously viewed stimuli. We found the same serial dependence in the perception of facial expression. This perceptual attraction extended over several trials and seconds, and displayed clear tuning to the difference (in orientation or facial expression between the sequential stimuli. Furthermore, serial dependence in object perception was spatially specific and selective to the attended object within a scene. Several control experiments showed that the perceptual serial dependence we report cannot be explained by effects of priming, known hysteresis effects, visual short-term memory, or expectation. Our results reveal a systematic influence of recent visual experiences on perception at any given moment: visual percepts, even of unambiguous stimuli, are attracted toward what was previously seen. We propose that such serial dependence helps to maintain

  15. Synchronic Seriality: The Dissolving of Diegetic Borders Through Metalepsis

    Directory of Open Access Journals (Sweden)

    Paige M. Piper

    2015-12-01

    Full Text Available In dialogue with Gérard Genette’s literary concept of metalepsis to television, this paper considers instances of meta-textual actor/character portrayals in serial narratives to show that meta-narrative intrusion fosters a greater empathetic link between the spectator and character, whilst simultaneously inviting the viewer to appreciate the technique as an artifice-aware gesture. The fluidity of diegetic borders brought on by the conflation of performer/performance replicates Baudrillard’s simulacra, creating a synchronic form of seriality and transcending rigid genre classifications.

  16. Quick, sensitive serial NMR experiments with Radon transform.

    Science.gov (United States)

    Dass, Rupashree; Kasprzak, Paweł; Kazimierczuk, Krzysztof

    2017-09-01

    The Radon transform is a potentially powerful tool for processing the data from serial spectroscopic experiments. It makes it possible to decode the rate at which frequencies of spectral peaks shift under the effect of changing conditions, such as temperature, pH, or solvent. In this paper we show how it also improves speed and sensitivity, especially in multidimensional experiments. This is particularly important in the case of low-sensitivity techniques, such as NMR spectroscopy. As an example, we demonstrate how Radon transform processing allows serial measurements of 15 N-HSQC spectra of unlabelled peptides that would otherwise be infeasible. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. IT-based Value Creation in Serial Acquisitions

    DEFF Research Database (Denmark)

    Henningsson, Stefan; Yetton, Philip

    2013-01-01

    serial acquirers realize IT-based value, we integrate and model the findings on individual acquisitions from the extant literature, and extend that model to explain the effects of sequential acquisitions in a growth-by-acquisition strategy. This extended model, drawing on the Resource-Based Theory......The extant research on post-acquisition IT integration analyzes how acquirers realize IT-based value in individual acquisitions. However, serial acquirers make 60% of acquisitions. These acquisitions are not isolated events, but are components in growth-by-acquisition programs. To explain how...

  18. Native sulfur/chlorine SAD phasing for serial femtosecond crystallography

    International Nuclear Information System (INIS)

    Nakane, Takanori; Song, Changyong; Suzuki, Mamoru; Nango, Eriko; Kobayashi, Jun; Masuda, Tetsuya; Inoue, Shigeyuki; Mizohata, Eiichi; Nakatsu, Toru; Tanaka, Tomoyuki; Tanaka, Rie; Shimamura, Tatsuro; Tono, Kensuke; Joti, Yasumasa; Kameshima, Takashi; Hatsui, Takaki; Yabashi, Makina; Nureki, Osamu; Iwata, So; Sugahara, Michihiro

    2015-01-01

    Sulfur SAD phasing facilitates the structure determination of diverse native proteins using femtosecond X-rays from free-electron lasers via serial femtosecond crystallography. Serial femtosecond crystallography (SFX) allows structures to be determined with minimal radiation damage. However, phasing native crystals in SFX is not very common. Here, the structure determination of native lysozyme from single-wavelength anomalous diffraction (SAD) by utilizing the anomalous signal of sulfur and chlorine at a wavelength of 1.77 Å is successfully demonstrated. This sulfur SAD method can be applied to a wide range of proteins, which will improve the determination of native crystal structures

  19. Postpartum Vaginal Blood Loss following Two Different Methods of Cervical Ripening

    Directory of Open Access Journals (Sweden)

    Okon Asuquo Okon

    2017-01-01

    Full Text Available Eighty women undergoing induction of labor at the University of Calabar Teaching Hospital were recruited and randomly allocated into two treatment groups (40 each, to receive either serial 50 µg doses of misoprostol or intracervical Foley catheter. Vaginal blood loss was collected and measured using an under buttocks plastic collection bag and by perineal pad weighing up to 6 hours postpartum. There were no significant differences between the two groups with respect to sociodemographic and obstetric characteristics. Comparison of blood loss in vaginal deliveries between the two groups revealed that subjects in the misoprostol group had significantly higher blood loss than subjects in the Foley catheter group (488 ± 222 versus 326 ± 106, p<0.05. In both groups, there was strong and statistically significant positive correlation between postpartum blood loss and induction delivery interval (r=0.75, p<0.0001; r=0.77, p<0.0001. There were no significant differences in maternal outcomes. In view of this, further study is required to ascertain if lower doses of misoprostol for induction of labor may result in lesser blood loss. This trial is registered with ISRCTN14479515.

  20. Serial correlation between the ultrasonographic and pathologic findings of intramuscular hemorrhaging in an experimental rabbit

    International Nuclear Information System (INIS)

    Ko, Kyung Ran; Ryu, Kyung Nam; Park, Ji Seon; Jin, Wook; Sung, Dong Wook; Park, Yong Koo

    2008-01-01

    To evaluate the serial ultrasonographic findings of experimental intramuscular hemorrhaging to determine if there is a correlation with the pathologic findings. An ultrasonography (US) was performed before and immediately after an intramuscular blood injection in nine rabbits. In addition, follow-up US images were obtained at 1, 4, 7, 10, 14, 21, and 28 days after the intramuscular blood injections in seven of the rabbits. The pathologic specimens, compared to the US findings on each date, and consisted of samples of left thigh muscle. A US, performed immediately after a blood injection, showed two patterns; 6 cases of hyperechoic muscle thickening and 3 cases of hyperechoic muscle thickening with extravasation between the epimysium and muscle bundle or within muscle bundle. A follow-up US showed a marked decrease in intramuscular hemorrhaging and microcalcifications, which appeared on the 4th, 7th and 10th day after the blood injection. The pathologic findings revealed several short echogenic lines in the muscular bundles which were hemosiderin. Moreover, a 28 day follow-up US revealed that the normal findings are correlated with the normal gross pathologic findings. The US findings of the intramuscular hemorrhaging, for each of the follow-up dates, in comparison to the pathologic findings, revealed a high correlation with the pathologic specimens. Consequently, a US transducer with high resolution can be considered as a helpful technique in the diagnosing and evaluating the follow-up treatment of intramuscular hemorrhaging

  1. Serial correlation between the ultrasonographic and pathologic findings of intramuscular hemorrhaging in an experimental rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kyung Ran [National Cancer Center, Seoul (Korea, Republic of); Ryu, Kyung Nam; Park, Ji Seon; Jin, Wook; Sung, Dong Wook; Park, Yong Koo [KyungHee University Medical Center, Seoul (Korea, Republic of)

    2008-05-15

    To evaluate the serial ultrasonographic findings of experimental intramuscular hemorrhaging to determine if there is a correlation with the pathologic findings. An ultrasonography (US) was performed before and immediately after an intramuscular blood injection in nine rabbits. In addition, follow-up US images were obtained at 1, 4, 7, 10, 14, 21, and 28 days after the intramuscular blood injections in seven of the rabbits. The pathologic specimens, compared to the US findings on each date, and consisted of samples of left thigh muscle. A US, performed immediately after a blood injection, showed two patterns; 6 cases of hyperechoic muscle thickening and 3 cases of hyperechoic muscle thickening with extravasation between the epimysium and muscle bundle or within muscle bundle. A follow-up US showed a marked decrease in intramuscular hemorrhaging and microcalcifications, which appeared on the 4th, 7th and 10th day after the blood injection. The pathologic findings revealed several short echogenic lines in the muscular bundles which were hemosiderin. Moreover, a 28 day follow-up US revealed that the normal findings are correlated with the normal gross pathologic findings. The US findings of the intramuscular hemorrhaging, for each of the follow-up dates, in comparison to the pathologic findings, revealed a high correlation with the pathologic specimens. Consequently, a US transducer with high resolution can be considered as a helpful technique in the diagnosing and evaluating the follow-up treatment of intramuscular hemorrhaging.

  2. [Prospects in blood transfusion].

    Science.gov (United States)

    Rouger, P

    2003-04-01

    What will be the evolution of blood transfusion in the next 10 years? What are the scientific and medical arguments to help the decision makers to propose the developments? Many scientific and clinical studies show that blood substitutes are not ready for use in man. So, for a long time, blood collection in man will still be a necessity to prepare cell concentrates (red blood cells and platelets) and fresh frozen plasma. During this period, blood safety will be based on development of testing technics and preparation processes of blood products. Another major point will be a better clinical use of blood derivates. Cellular therapy will be probably only a way of diversification in blood transfusion centers in partnership with hospitals.

  3. Recommendations for CAMAC Serial Highway drivers and LAM Graders for the SCC-L2 Serial Crate Controller

    International Nuclear Information System (INIS)

    1978-01-01

    The functional requirements of Drivers for the CAMAC Serial Highway defined in IEEE Standard 595-1976 are described. The description is independent of the implementation, and in particular no assumption is made about the boundary between hardware and software within the Driver. Topics covered are the user interface, the supporting system services required, demand handling, and a detailed discussion of the message analysis for various levels of error recovery. An appendix describes the recommended features of LAM Graders for use with the Serial Crate Controller Type L2 of IEEE Std 595-1976

  4. Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries.

    Science.gov (United States)

    Nurgalieva, Z Z; Almuchambetova, R; Machmudova, A; Kapsultanova, D; Osato, M S; Peacock, J; Zoltek, R P; Marchildon, P A; Graham, D Y; Zhangabylov, A

    2000-11-01

    Studies are difficult in areas lacking modern facilities due to the inability to reliably collect, store, and ship samples. Thus, we sought to evaluate the use of a dry plasma collection device for seroepidemiology studies. Plasma was obtained by fingerstick using a commercial dry plasma collection device (Chemcard Plasma Collection Device) and serum (venipuncture) from individuals in Kazakhstan. Plasma samples were air dried for 15 min and then stored desiccated in foil zip-lock pouches at 4 to 6 degrees C and subsequently shipped to the United States by air at ambient temperature. Serum samples remained frozen at -20 degrees C until assayed. Helicobacter pylori status was determined by enzyme-linked immunosorbent assay (HM-CAP EIA) for the dry plasma and the serum samples. The results were concordant in 250 of the 289 cases (86.5%). In 25 cases (8.6%), the dry plasma samples gave indeterminate results and could not be retested because only one sample was collected. Five serum samples were positive, and the corresponding dry plasma samples were negative; one serum sample was negative, and the corresponding plasma sample was positive. The relative sensitivity and specificity of the Chemcard samples to serum were 97.6 and 97.9%, respectively, excluding those with indeterminate results. Repeated freeze-thawing had no adverse effect on the accuracy of the test. We found the dry plasma collection device to provide an accurate and practical alternative to serum when venipuncture may be difficult or inconvenient and sample storage and handling present difficulties, especially for seroepidemiologic studies in rural areas or developing countries and where freeze-thawing may be unavoidable.

  5. Serial assessment of left ventricular function following coronary bypass surgery by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Kawasuji, Michio; Sawa, Shigeharu; Sakakibara, Naoki; Iwa, Takashi; Taki, Junichi; Bunko, Hisashi

    1988-01-01

    The serial change in left ventricular function was investigated by radionuclide angiocardiography in 25 patients undergoing coronary artery bypass grafting (CABG). Multiple gated equilibrium blood pool imaging was performed at rest before, and at 1, 2 and 4 weeks after the operation and also during exercise on a supine bicycle ergometer before and 4 weeks after surgery. Global ejection fraction at rest was unchanged after CABG while peak ejection rate increased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05 respectively) after the operation. Peak filling rate at rest was generally unchanged after surgery but peak filling rate during the first third of diastole at rest decreased significantly at 1 and 2 weeks (p < 0.01 and p < 0.05). After CABG, the increases in ejection fraction and peak ejection rate with exercise were significantly greater than those values measured before surgery. The increases, due to exercise, in peak filling rate and peak filling rate during the first third of diastole were unchanged after the operation. Radionuclide angiocardiography affords a safe, noninvasive, and highly reproducible procedure for serially assessing ventricular function in patients undergoing CABG. Our study revealed early diastolic dysfunction within 2 weeks of surgery and that CABG abolished abnormalities in left ventricular function induced by exercise. (author)

  6. The Influence of Serial Carbohydrate Mouth Rinsing on Power Output during a Cycle Sprint

    Directory of Open Access Journals (Sweden)

    Shaun M. Phillips, Scott Findlay, Mykolas Kavaliauskas, Marie Clare Grant

    2014-06-01

    Full Text Available The objective of the study was to investigate the influence of serial administration of a carbohydrate (CHO mouth rinse on performance, metabolic and perceptual responses during a cycle sprint. Twelve physically active males (mean (± SD age: 23.1 (3.0 years, height: 1.83 (0.07 m, body mass (BM: 86.3 (13.5 kg completed the following mouth rinse trials in a randomized, counterbalanced, double-blind fashion; 1. 8 x 5 second rinses with a 25 ml CHO (6% w/v maltodextrin solution, 2. 8 x 5 second rinses with a 25 ml placebo (PLA solution. Following mouth rinse administration, participants completed a 30 second sprint on a cycle ergometer against a 0.075 g·kg-1 BM resistance. Eight participants achieved a greater peak power output (PPO in the CHO trial, resulting in a significantly greater PPO compared with PLA (13.51 ± 2.19 vs. 13.20 ± 2.14 W·kg-1, p 0.05. No significant between-trials difference was reported for fatigue index, perceived exertion, arousal and nausea levels, or blood lactate and glucose concentrations. Serial administration of a CHO mouth rinse may significantly improve PPO during a cycle sprint. This improvement appears confined to the first 5 seconds of the sprint, and may come at a greater relative cost for the remainder of the sprint.

  7. Kiondo Bag Boutique: A Serial Case for Introductory Financial Accounting

    Science.gov (United States)

    Siriwardane, Harshini P.

    2014-01-01

    Kiondo Bag Boutique is a hypothetical serial case involving a start-up retail business. The case evolves from an ambitious business idea to a successful business. Through the evolving business, the importance of accounting information is highlighted. Different iterations are used to illustrate the role of accounting in serving and managing…

  8. 'American Psycho': a double portrait of serial yuppie Patrick Bateman

    NARCIS (Netherlands)

    Kooijman, J.; Laine, T.

    2003-01-01

    Kooijman and Laine analyze Mary Harron's "American Psycho," a 2000 film adaptation of the 1980s satirical novel by Bret Easton Ellis in which Patrick Bateman, a narcissistic Wall Street young urban professional ("yuppie"), assumes an alternate identity as a serial killer. The authors examine the

  9. The stand-alone test and decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Thorlund-Petersen, Lars

    2000-01-01

    The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability...

  10. Serial Comparison Processes and Sex Differences in Clerical Speed.

    Science.gov (United States)

    Majeres, Raymond L.

    1988-01-01

    Three experiments were conducted with 91 male and 91 female university students to assess sex differences in performance on speeded matching tests and theory on same-different judgments. Results are interpreted via the dual-process hypothesis of same-difference judgments with sex differences explained in terms of serial comparison processes rather…

  11. Serials Management by Microcomputer: The Potential of DBMS.

    Science.gov (United States)

    Vogel, J. Thomas; Burns, Lynn W.

    1984-01-01

    Describes serials management at Philadelphia College of Textiles and Science library via a microcomputer, a file manager called PFS, and a relational database management system called dBase II. Check-in procedures, programing with dBase II, "static" and "active" databases, and claim procedures are discussed. Check-in forms are…

  12. Phonological Similarity in Serial Recall: Constraints on Theories of Memory

    Science.gov (United States)

    Lewandowsky, Stephan; Farrell, Simon

    2008-01-01

    In short-term serial recall, similar-sounding items are remembered more poorly than items that do not sound alike. When lists mix similar and dissimilar items, performance on the dissimilar items is of considerable theoretical interest. Farrell and Lewandowsky [Farrell, S., & Lewandowsky, S. (2003). Dissimilar items benefit from phonological…

  13. Development of parallel/serial program analyzing tool

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Nagao, Saichi; Takigawa, Yoshio; Kumakura, Toshimasa

    1999-03-01

    Japan Atomic Energy Research Institute has been developing 'KMtool', a parallel/serial program analyzing tool, in order to promote the parallelization of the science and engineering computation program. KMtool analyzes the performance of program written by FORTRAN77 and MPI, and it reduces the effort for parallelization. This paper describes development purpose, design, utilization and evaluation of KMtool. (author)

  14. Auditory distraction and serial memory: The avoidable and the ineluctable

    Directory of Open Access Journals (Sweden)

    Dylan M Jones

    2010-01-01

    Full Text Available One mental activity that is very vulnerable to auditory distraction is serial recall. This review of the contemporary findings relating to serial recall charts the key determinants of distraction. It is evident that there is one form of distraction that is a joint product of the cognitive characteristics of the task and of the obligatory cognitive processing of the sound. For sequences of sound, distraction appears to be an ineluctable product of similarity-of-process, specifically, the serial order processing of the visually presented items and the serial order coding that is the by-product of the streaming of the sound. However, recently emerging work shows that the distraction from a single sound (one deviating from a prevailing sequence results in attentional capture and is qualitatively distinct from that of a sequence in being restricted in its action to encoding, not to rehearsal of list members. Capture is also sensitive to the sensory task load, suggesting that it is subject to top-down control and therefore avoidable. These two forms of distraction-conflict of process and attentional capture-may be two consequences of auditory perceptual organization processes that serve to strike the optimal balance between attentional selectivity and distractability.

  15. Asymmetric binding in serial memory for verbal and spatial information

    NARCIS (Netherlands)

    Guerard, Katherine; Morey, Candice C.; Lagace, Sebastien; Tremblay, Sebastien

    As the number of studies showing that items can be retained as bound representations in memory increases, researchers are beginning to investigate how the different features are bound together. In the present study, we examined the relative importances of the verbal and spatial features in serial

  16. FPGA based fast synchronous serial multi-wire links synchronization

    Science.gov (United States)

    Pozniak, Krzysztof T.

    2013-10-01

    The paper debates synchronization method of multi-wire, serial link of constant latency, by means of pseudo-random numbers generators. The solution was designed for various families of FPGA circuits. There were debated synchronization algorithm and functional structure of parameterized transmitter and receiver modules. The modules were realized in VHDL language in a behavioral form.

  17. Asymmetrical learning between a tactile and visual serial RT task

    NARCIS (Netherlands)

    Abrahamse, E.L.; van der Lubbe, Robert Henricus Johannes; Verwey, Willem B.

    2007-01-01

    According to many researchers, implicit learning in the serial reaction-time task is predominantly motor based and therefore should be independent of stimulus modality. Previous research on the task, however, has focused almost completely on the visual domain. Here we investigated sequence learning

  18. Serial assessment of doxorubicin cardiomyopathy with the computerized scintillation probe

    International Nuclear Information System (INIS)

    Strashun, A.; Goldsmith, S.J.; Horowitz, S.F.

    1982-01-01

    Cardiac function was serially monitored in 55 patients receiving adriamycin chemotherapy over 18 months with quantitative radionuclide assessment by both a nonimaging computerized scintillation probe and gamma camera-computer imaging. Interval ejection fraction change was comparable with both techniques and predicted incipient cardiotoxicity. Probe data revealed ejection fraction decline was antedated by decline left ventricular emptying and filling rates

  19. Using identification in entertainment-education drama serials to ...

    African Journals Online (AJOL)

    The study used two entertainment-education drama serials which were designed using Albert Bandura's theoretical framework to communicate positive messages of women's rights to real life audiences in select communities. The study sought to find out if there was any significant relationship i.e. identification between TV ...

  20. Counterbalancing for Serial Order Carryover Effects in Experimental Condition Orders

    Science.gov (United States)

    Brooks, Joseph L.

    2012-01-01

    Reactions of neural, psychological, and social systems are rarely, if ever, independent of previous inputs and states. The potential for serial order carryover effects from one condition to the next in a sequence of experimental trials makes counterbalancing of condition order an essential part of experimental design. Here, a method is proposed…

  1. Mixed-List Phonological Similarity Effects in Delayed Serial Recall

    Science.gov (United States)

    Farrell, Simon

    2006-01-01

    Recent experiments have shown that placing dissimilar items on lists of phonologically similar items enhances accuracy of ordered recall of the dissimilar items [Farrell, S., & Lewandowsky, S. (2003). Dissimilar items benefit from phonological similarity in serial recall. "Journal of Experimental Psychology: Learning, Memory, and Cognition," 29,…

  2. Electronic conductance of quantum wire with serial periodic potential structures

    International Nuclear Information System (INIS)

    Fayad, Hisham M.; Shabat, Mohammed M.; Abdus Salam International Centre for Theoretical Physics, Trieste

    2000-08-01

    A theory based on the total transfer matrix is presented to investigate the electronic conductance in a quantum wire with serial periodic potentials. We apply the formalism in computation of the electronic conductance in a wire with different physical parameters of the wire structure. The numerical results could be used in designing some future quantum electronic devices. (author)

  3. Analysis of aging in lager brewing yeast during serial repitching.

    Science.gov (United States)

    Bühligen, Franziska; Lindner, Patrick; Fetzer, Ingo; Stahl, Frank; Scheper, Thomas; Harms, Hauke; Müller, Susann

    2014-10-10

    Serial repitching of brewing yeast inoculates is an important economic factor in the brewing industry, as their propagation is time and resource intensive. Here, we investigated whether replicative aging and/or the population distribution status changed during serial repitching in three different breweries with the same brewing yeast strain but different abiotic backgrounds and repitching regimes with varying numbers of reuses. Next to bud scar numbers the DNA content of the Saccharomyces pastorianus HEBRU cells was analyzed. Gene expression patterns were investigated using low-density microarrays with genes for aging, stress, storage compound metabolism and cell cycle. Two breweries showed a stable rejuvenation rate during serial repitching. In a third brewery the fraction of virgin cells varied, which could be explained with differing wort aeration rates. Furthermore, the number of bud scars per cell and cell size correlated in all 3 breweries throughout all runs. Transcriptome analyses revealed that from the 6th run on, mainly for the cells positive gene expression could be seen, for example up-regulation of trehalose and glycogen metabolism genes. Additionally, the cells' settling in the cone was dependent on cell size, with the lowest and the uppermost cone layers showing the highest amount of dead cells. In general, cells do not progressively age during extended serial repitching. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Serials use in a College of Agriculture Education Library | Adzobu ...

    African Journals Online (AJOL)

    Serials use in a College of Agriculture Education Library. J Adzobu, JA Opare. Abstract. No Abstract. Ghana Library Journal Vol. 20 (1) 2008: pp. 81-88. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Article Metrics. Metrics Loading ... Metrics powered by PLOS ALM

  5. Child serial murder-psychodynamics: closely watched shadows.

    Science.gov (United States)

    Turco, R

    2001-01-01

    There is a malignant transformation in object relations resulting in an identification with an omnipotent and cruel object resulting in an identity transformation. If the tension, desperation, and dissociation increase, serial murder becomes spree murder. The presence of pathological narcissism and psychopathic tendencies are of diagnostic significance in understanding the murderer's personality functioning and motivation to kill. Meloy (1988) considered the degree of sadism and aggression combined with narcissistic qualities to reflect the "malignancy" of the psychopathic disturbance where gratification (of aggression) occurs in the service of narcissistic functioning--that is, cruelty toward others in the form of a triumphant victory over a rejecting object. Meloy also believes that dissociation is ubiquitious in the psychopath. The initial murder of the serial murderer may reflect a "new identity." The pathological object-relations of narcissism and the malignant narcissism are important diagnostic indicators in the personality functioning of serial killers and the occurrence of these phenomena is a significant factor in the formation of the personalities of serial killers, their inner motivations, and their pattern of commission.

  6. Serial Killers: Academic Libraries Respond to Soaring Costs.

    Science.gov (United States)

    McCarthy, Paul

    1994-01-01

    Discusses ways in which academic libraries are responding to rising costs of serials. Topics addressed include pricing by publishers; the effect of journal cancellations on research activities; interlibrary loans and document delivery services; coordinated cancelling; electronic journals; and experiences at the University of Arizona. (LRW)

  7. Effect of Blood Collection Tube Type and Time to Processing on the Enumeration and High-Content Characterization of Circulating Tumor Cells Using the High-Definition Single-Cell Assay.

    Science.gov (United States)

    Rodríguez-Lee, Mariam; Kolatkar, Anand; McCormick, Madelyn; Dago, Angel D; Kendall, Jude; Carlsson, Nils Anders; Bethel, Kelly; Greenspan, Emily J; Hwang, Shelley E; Waitman, Kathryn R; Nieva, Jorge J; Hicks, James; Kuhn, Peter

    2018-02-01

    - As circulating tumor cell (CTC) assays gain clinical relevance, it is essential to address preanalytic variability and to develop standard operating procedures for sample handling in order to successfully implement genomically informed, precision health care. - To evaluate the effects of blood collection tube (BCT) type and time-to-assay (TTA) on the enumeration and high-content characterization of CTCs by using the high-definition single-cell assay (HD-SCA). - Blood samples of patients with early- and advanced-stage breast cancer were collected into cell-free DNA (CfDNA), EDTA, acid-citrate-dextrose solution, and heparin BCTs. Time-to-assay was evaluated at 24 and 72 hours, representing the fastest possible and more routine domestic shipping intervals, respectively. - We detected the highest CTC levels and the lowest levels of negative events in CfDNA BCT at 24 hours. At 72 hours in this BCT, all CTC subpopulations were decreased with the larger effect observed in high-definition CTCs and cytokeratin-positive cells smaller than white blood cells. Overall cell retention was also optimal in CfDNA BCT at 24 hours. Whole-genome copy number variation profiles were generated from single cells isolated from all BCT types and TTAs. Cells from CfDNA BCT at 24-hour TTA exhibited the least noise. - Circulating tumor cells can be identified and characterized under a variety of collection, handling, and processing conditions, but the highest quality can be achieved with optimized conditions. We quantified performance differences of the HD-SCA for specific preanalytic variables that may be used as a guide to develop best practices for implementation into patient care and/or research biorepository processes.

  8. Using Dried Blood Spot Sampling to Improve Data Quality and Reduce Animal Use in Mouse Pharmacokinetic Studies

    Science.gov (United States)

    Wickremsinhe, Enaksha R; Perkins, Everett J

    2015-01-01

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959

  9. Blood, sweat and plaster casts: Reviewing the history, composition, and scientific value of the Raymond A. Dart Collection of African Life and Death Masks.

    Science.gov (United States)

    Houlton, T M R; Billings, B K

    2017-10-01

    This paper addresses the history, composition and scientific value of one of the most comprehensive facemask collections in Africa, the Raymond A. Dart Collection of African Life and Death Masks. Housed within the School of Anatomical Sciences at the University of the Witwatersrand (South Africa), it comprises 1110 masks (397 life, 487 death, 226 unknown). Life masks represent populations throughout Africa; death masks predominately southern Africa. Males preponderate by 75%. Recorded ages are error prone, but suggest most life masks are those of <35 year-olds, death masks of 36+ year-olds. A total of 241 masks have associated skeletons, 209 presenting a complete skull. Life masks date between 1927 and c.1980s, death masks 1933 and 1963. This historical collection presents uncanny associations with outmoded typological and evolutionary theories. Once perceived an essential scientific resource, performed craniofacial superimpositions identify the nose as the only stable feature maintained, with the remaining face best preserved in young individuals with minimal body fat. The facemask collection is most viable for teaching and research within the history of science, specifically physical anthropology, and presents some value to craniofacial identification. Future research will have to be conducted with appropriate ethical considerations to science and medicine. Copyright © 2017 Elsevier GmbH. All rights reserved.

  10. Blood Meal Analysis of and Virus Detection in Mosquitoes Collected during a Rift Valley fever Epizootic/Epidemic: Implications for epidemic disease transmission dynamics

    Science.gov (United States)

    Rift Valley fever (RVF) is a zoonosis of domestic ruminants in Africa. Bloodfed mosquitoes collected during the 2006-2007 RVF outbreak in Kenya were analyzed to determine the virus infection status and animal source of the bloodmeals. Bloodmeals from individual mosquito abdomens were screened for v...

  11. Serial MR imaging evaluation of effects of radiation therapy on bone marrow and liver

    International Nuclear Information System (INIS)

    Yankelevitz, D.; Henschke, C.I.; Chu, F.; Hayt, D.B.; Whalen, J.P.; Cahill, P.T.

    1989-01-01

    This paper reports on baseline and serial MR imaging studies obtained on 20 patients (lung cancer and lymphoma) who were receiving radiation therapy as their only form of treatment. Quantitative and qualitative MR signal intensity measurement were made on bone marrow and liver. Additionally, changes in signal intensity were correlated with laboratory values including both complete blood count and liver function tests. The spine showed increased signal intensity on T1-weighted images. MR signal intensity increased rapidly in the first 6 weeks and continued to rise slowly thereafter. In three of 10 cases in which the liver was included in the radiotherapy field, areas of increased activity in the liver were seen on T2-weighted images. These areas were in the field of radiation and sharply demarcated from nonirradiated liver. This area of abnormality gradually returned to normal after completion of therapy

  12. Reconstructing genealogies of serial samples under the assumption of a molecular clock using serial-sample UPGMA.

    Science.gov (United States)

    Drummond, A; Rodrigo, A G

    2000-12-01

    Reconstruction of evolutionary relationships from noncontemporaneous molecular samples provides a new challenge for phylogenetic reconstruction methods. With recent biotechnological advances there has been an increase in molecular sequencing throughput, and the potential to obtain serial samples of sequences from populations, including rapidly evolving pathogens, is fast being realized. A new method called the serial-sample unweighted pair grouping method with arithmetic means (sUPGMA) is presented that reconstructs a genealogy or phylogeny of sequences sampled serially in time using a matrix of pairwise distances. The resulting tree depicts the terminal lineages of each sample ending at a different level consistent with the sample's temporal order. Since sUPGMA is a variant of UPGMA, it will perform best when sequences have evolved at a constant rate (i.e., according to a molecular clock). On simulated data, this new method performs better than standard cluster analysis under a variety of longitudinal sampling strategies. Serial-sample UPGMA is particularly useful for analysis of longitudinal samples of viruses and bacteria, as well as ancient DNA samples, with the minimal requirement that samples of sequences be ordered in time.

  13. Smart grid serialization comparison: Comparision of serialization for distributed control in the context of the Internet of Things

    DEFF Research Database (Denmark)

    Petersen, Bo Søborg; Bindner, Henrik W.; You, Shi

    2017-01-01

    within a given timeframe, especially in the context of the Internet of Things, using low-bandwidth data connections and constrained devices. The paper shows that there are better alternatives than XML & JAXB and gives guidance in choosing the most appropriate serialization format and library depending...

  14. Can a barcode scanner for blood collection improve patient identification integrity in the emergency department? A prospective before-and-after study.

    Science.gov (United States)

    Spain, David; Crilly, Julia; Pierce, John; Steele, Michael; Scuffham, Paul; Keijzers, Gerben

    2015-02-01

    To describe the effect of interventions designed to improve patient identification (PI) during pathology collection in the ED. A prospective before-and-after intervention study was conducted between June 2009 and June 2010 in a regional ED in Queensland, Australia. Interventions aimed to improve PI and specimen labelling, and consisted of: (i) education alone; and (ii) education plus an armband scanner that voice-prompted collector behaviour. Main outcomes measured included: frequency of correct key behaviours (KBs) during specimen collection, pathology integrity errors and cost of interventions. Data from 282 ED pathology collections were analysed (before: n = 115, after with education: n = 95, after with education plus armband scanner: n = 72). KBs for PI and labelling improved significantly following education plus armband scanner use. Application of armbands before sample collection increased (36% vs 90%, P patient to state their name (25% vs 93%, P patient misidentification was detected in this small study. The annual costs for a hospital to adopt the education programme with and without the armband scanner were $104,045 and $5330 respectively. ED staff had poor behaviours for identifying patients and labelling pathology specimens before intervention. These safety behaviours were considered an assumed skill. Education alone improved critical KBs markedly that was further augmented by the armband scanner. The cost to adopt education alone is relatively low compared to the addition of armband scanner technology. © 2015 The Authors. Emergency Medicine Australasia published by Wiley Publishing Asia Pty Ltd on behalf of Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  15. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to help stay current with the latest advances in the field Hematology 2017 A collection of articles from ... Blood clots in pregnant women tend to form in the deep veins of the legs or in the ...

  16. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Abstracts Blood Advances A peer-reviewed, online only, open access ... to help stay current with the latest advances in the field Hematology 2017 A collection of articles from the ...

  17. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Assessment Program A comprehensive resource to help stay current with the latest advances in the field Hematology 2017 A collection of articles from the 2017 ASH Annual Meeting Education Program Blood: How I Treat A compendium of ...

  18. A novel system for providing compatible blood to patients during surgery: "self-service" electronic blood banking by nursing staff.

    Science.gov (United States)

    Cheng, G; Chiu, D S; Chung, A S; Wong, H F; Chan, M W; Lui, Y K; Choy, F M; Chan, J C; Chan, A H; Lam, S T; Fan, T C

    1996-04-01

    A good blood bank must be able to provide compatible blood units promptly to operating room patients with minimal wastage. A "self-service" by nursing staff blood banking system that is safe, efficient, and well-accepted has been developed. Specific blood units are no longer assigned to surgical patients who have a negative pretransfusion antibody screen, irrespective of the type of surgery. A computer-generated list of the serial numbers of all group-identical blood units currently in the blood bank inventory is provided for each patient. The units themselves are not labeled with a patient's name. The group O list will be provided for group O patients, the group A list for group A patients, and so forth. Should the patient require transfusion during surgery, the operating room nurses go to the refrigerator, remove any group-identical unit, and check the serial number of the unit against the serial numbers on the patient's list. If the serial number is on that list, the blood bank will accept responsibility for compatibility. The system was implemented in 1995. Since implementation, a total of 2154 patients have undergone operations at this hospital. Thirty-two patients received more than 10 units of red cells each. There were no transfusion errors. The crossmatch-to-transfusion ratio was reduced from 1.67 to 1.12. Turnaround time for supplying additional or urgent units to patients in operating room was shortened from 33 to 2.5 minutes. There was no incidence of a blood unit's serial number not being on the list. Work by nurses and technical staff was reduced by nearly 50 percent. The "self-service" (by nursing staff) blood banking system described is safe and efficient. It saves staff time and can be easily set up.

  19. Muscle atrophy and metal-on-metal hip implants: a serial MRI study of 74 hips.

    Science.gov (United States)

    Berber, Reshid; Khoo, Michael; Cook, Erica; Guppy, Andrew; Hua, Jia; Miles, Jonathan; Carrington, Richard; Skinner, John; Hart, Alister

    2015-06-01

    Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. We retrospectively reviewed 74 hips in 56 patients (32 of them women) using serial MRI. Median age was 59 (23-83) years. The median time post-implantation was 83 (35-142) months, and the median interval between scans was 11 months. Hip muscles were scored using the Pfirrmann system. The mean scores for muscle atrophy were compared between the first and second MRI scans. Blood cobalt and chromium concentrations were determined. The median blood cobalt was 6.84 (0.24-90) ppb and median chromium level was 4.42 (0.20-45) ppb. The median Oxford hip score was 34 (5-48). The change in the gluteus minimus mean atrophy score between first and second MRI was 0.12 (p = 0.002). Mean change in the gluteus medius posterior portion (unaffected by surgical approach) was 0.08 (p = 0.01) and mean change in the inferior portion was 0.10 (p = 0.05). Mean pseudotumor grade increased by 0.18 (p = 0.02). Worsening muscle atrophy and worsening pseudotumor grade occur over a 1-year period in a substantial proportion of patients with MOM hip implants. Serial MRI helps to identify those patients who are at risk of developing worsening soft-tissue pathology. These patients should be considered for revision surgery before irreversible muscle destruction occurs.

  20. Accounting for partiality in serial crystallography using ray-tracing principles

    International Nuclear Information System (INIS)

    Kroon-Batenburg, Loes M. J.; Schreurs, Antoine M. M.; Ravelli, Raimond B. G.; Gros, Piet

    2015-01-01

    Serial crystallography generates partial reflections from still diffraction images. Partialities are estimated with EVAL ray-tracing simulations, thereby improving merged reflection data to a similar quality as conventional rotation data. Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialities based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a ‘still’ Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R int factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R int of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography

  1. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy.

    Science.gov (United States)

    Burnett, T L; Kelley, R; Winiarski, B; Contreras, L; Daly, M; Gholinia, A; Burke, M G; Withers, P J

    2016-02-01

    Ga(+) Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga(+) FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe(+) Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC-Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga(+) FIB milling WC-Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60nA at 30kV. Xe(+) PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Accounting for partiality in serial crystallography using ray-tracing principles

    Energy Technology Data Exchange (ETDEWEB)

    Kroon-Batenburg, Loes M. J., E-mail: l.m.j.kroon-batenburg@uu.nl; Schreurs, Antoine M. M. [Utrecht University, Padualaan 8, 3584 CH Utrecht (Netherlands); Ravelli, Raimond B. G. [Maastricht University, PO Box 616, 6200 MD Maastricht (Netherlands); Gros, Piet [Utrecht University, Padualaan 8, 3584 CH Utrecht (Netherlands)

    2015-08-25

    Serial crystallography generates partial reflections from still diffraction images. Partialities are estimated with EVAL ray-tracing simulations, thereby improving merged reflection data to a similar quality as conventional rotation data. Serial crystallography generates ‘still’ diffraction data sets that are composed of single diffraction images obtained from a large number of crystals arbitrarily oriented in the X-ray beam. Estimation of the reflection partialities, which accounts for the expected observed fractions of diffraction intensities, has so far been problematic. In this paper, a method is derived for modelling the partialities by making use of the ray-tracing diffraction-integration method EVAL. The method estimates partialities based on crystal mosaicity, beam divergence, wavelength dispersion, crystal size and the interference function, accounting for crystallite size. It is shown that modelling of each reflection by a distribution of interference-function weighted rays yields a ‘still’ Lorentz factor. Still data are compared with a conventional rotation data set collected from a single lysozyme crystal. Overall, the presented still integration method improves the data quality markedly. The R factor of the still data compared with the rotation data decreases from 26% using a Monte Carlo approach to 12% after applying the Lorentz correction, to 5.3% when estimating partialities by EVAL and finally to 4.7% after post-refinement. The merging R{sub int} factor of the still data improves from 105 to 56% but remains high. This suggests that the accuracy of the model parameters could be further improved. However, with a multiplicity of around 40 and an R{sub int} of ∼50% the merged still data approximate the quality of the rotation data. The presented integration method suitably accounts for the partiality of the observed intensities in still diffraction data, which is a critical step to improve data quality in serial crystallography.

  3. Serial Learning Process: Test of Chaining, Position, and Dual-Process Hypotheses

    Science.gov (United States)

    Giurintano, S. L.

    1973-01-01

    The chaining, position, and dual-process hypotheses of serial learning (SL) as well as serial recall, reordering, and relearning of paired-associate learning were examined to establish learning patterns. Results provide evidence for dual-process hypothesis. (DS)

  4. Ranking serials in oceanography: An analysis based on the Indian contributions and their citations

    Digital Repository Service at National Institute of Oceanography (India)

    Tapaswi, M.P.; Maheswarappa, B.S.

    An analysis of serials preferred and cited in various communications by the Indian oceanographers during 1963 to 1992 is presented. A shift in preference of serials from general sciences to oceanography (interdisciplinary) and to core subject...

  5. Mobilization and collection of CD34+ cells for autologous transplantation of peripheral blood hematopoietic progenitor cells in children: analysis of two different granulocyte-colony stimulating factor doses

    Directory of Open Access Journals (Sweden)

    Kátia Aparecida de Brito Eid

    2015-06-01

    Full Text Available Introduction: The use of peripheral hematopoietic progenitor cells (HPCs is the cell choice in autologous transplantation. The classic dose of granulocyte-colony stimulating factor (G- CSF for mobilization is a single daily dose of 10 µg/kg of patient body weight. There is a theory that higher doses of granulocyte-colony stimulating factor applied twice daily could increase the number of CD34+ cells collected in fewer leukapheresis procedures. Objective: The aim of this study was to compare a fractionated dose of 15 µg G-CSF/kg of body weight and the conventional dose of granulocyte-colony stimulating factor in respect to the number of leukapheresis procedures required to achieve a minimum collection of 3 × 106 CD34+ cells/kg body weight. Methods: Patients were divided into two groups: Group 10 - patients who received a single daily dose of 10 µg G-CSF/kg body weight and Group 15 - patients who received a fractioned dose of 15 µg G-CSF/kg body weight daily. The leukapheresis procedure was carried out in an automated cell separator. The autologous transplantation was carried out when a minimum number of 3 × 106 CD34+ cells/kg body weight was achieved. Results: Group 10 comprised 39 patients and Group 15 comprised 26 patients. A total of 146 apheresis procedures were performed: 110 (75.3% for Group 10 and 36 (24.7% for Group 15. For Group 10, a median of three (range: 1-7 leukapheresis procedures and a mean of 8.89 × 106 CD34+ cells/kg body weight (±9.59 were collected whereas for Group 15 the corresponding values were one (range: 1-3 and 5.29 × 106 cells/kg body weight (±4.95. A statistically significant difference was found in relation to the number of apheresis procedures (p-value <0.0001. Conclusions: To collect a minimum target of 3 × 106 CD34+ cells/kg body weight, the administration of a fractionated dose of 15 µg G-CSF/kg body weight significantly decreased the number of leukapheresis procedures performed.

  6. The effect of changing stool collection processes on compliance in nationwide organized screening using a fecal occult blood test (FOBT) in Korea: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Shin, Hye Young; Suh, Mina; Baik, Hyung Won; Choi, Kui Son; Park, Boyoung; Jun, Jae Kwan; Lee, Chan Wha; Oh, Jae Hwan; Lee, You Kyoung; Han, Dong Soo; Lee, Do-Hoon

    2014-11-26

    Colorectal cancer (CRC) screening by fecal occult blood test (FOBT) significantly reduces CRC mortality, and compliance rates directly influence the efficacy of this screening method. The aim of this study is to investigate whether stool collection strategies affect compliance with the FOBT. In total, 3,596 study participants aged between 50 and 74 years will be recruited. The study will be conducted using a randomized controlled trial, with a 2 × 2 factorial design resulting in four groups. The first factor is the method of stool-collection device distribution (mailing vs. visiting the clinic) and the second is the type of stool-collection device (sampling kit vs. conventional container). Participants will be randomly assigned to one of four groups: (1) sampling kit received by mail; (2) conventional container received by mail; (3) sampling kit received at the clinic; (4) conventional container received at the clinic (control group). The primary outcome will be the FOBT compliance rate; satisfaction and intention to be rescreened in the next screening round will also be evaluated. The rates of positive FOBT results and detection of advanced adenomas or cancers through colonoscopies will also be compared between the two collection containers. Identifying a method of FOBT that yields high compliance rates will be a key determinant of the success of CRC screening. The findings of this study will provide reliable information for health policy makers to develop evidence-based strategies for a high compliance rate. KCT0000803 Date of registration in primary registry: 9 January, 2013.

  7. Donating Blood

    Science.gov (United States)

    ... The medical history includes questions that help blood bank staff decide if a person is healthy enough to donate blood. They'll ... Food and Drug Administration (FDA) regulates U.S. blood banks. All blood ... operating. Sometimes people who donate blood notice a few minor side ...

  8. Impact of Serials Management, Access and Use on Publication Output of Lecturers in Nigerian Universities

    Science.gov (United States)

    Akinbode, Rahmon O. Onaolapo; Nwalo, Kenneth Ivo Ngozi

    2017-01-01

    This study investigates serials management in university libraries, determines the extent to which serials are accessed and used and appraises the influence of availability, accessibility and use of serials on publications output of lecturers in federal universities in Nigeria. Questionnaire administration method was adopted to accumulate data for…

  9. A constrained rasch model of trace redintegration in serial recall.

    Science.gov (United States)

    Roodenrys, Steven; Miller, Leonie M

    2008-04-01

    The notion that verbal short-term memory tasks, such as serial recall, make use of information in long-term as well as in short-term memory is instantiated in many models of these tasks. Such models incorporate a process in which degraded traces retrieved from a short-term store are reconstructed, or redintegrated (Schweickert, 1993), through the use of information in long-term memory. This article presents a conceptual and mathematical model of this process based on a class of item-response theory models. It is demonstrated that this model provides a better fit to three sets of data than does the multinomial processing tree model of redintegration (Schweickert, 1993) and that a number of conceptual accounts of serial recall can be related to the parameters of the model.

  10. Plastic optical fiber serial communications link for distributed control system

    Science.gov (United States)

    Saxena, Piyush; Sharangpani, K. K.; Vora, H. S.; Nakhe, S. V.; Jain, R.; Shenoy, N. M.; Bhatnagar, R.; Shirke, N. D.

    2001-09-01

    One of the most common interface for communications specified is RS 232C standard. Though widely accepted, RS232 has limited transmission speed, range and networking capabilities. RS 422 standard overcomes limitations by using differential signal lines. In automation of the operation of gas discharge lasers, multiple processors are used for control of lasers, cooling system, vacuum system etc. High EMI generated by lasers interfere through galvanic transmission or by radiation over the length of cables, and hang up operation of processors or control PC. A serial communications link was designed eliminating copper transmission media, using plastic optical fiber cables and components, to connect local controllers with the master PC working on RS232 protocols. The paper discusses the design and implementation of a high ly reliable EMI harden serial communications link.

  11. Serial network simplifies the design of multiple microcomputer systems

    Energy Technology Data Exchange (ETDEWEB)

    Folkes, D.

    1981-01-01

    Recently there has been a lot of interest in developing network communication schemes for carrying digital data between locally distributed computing stations. Many of these schemes have focused on distributed networking techniques for data processing applications. These applications suggest the use of a serial, multipoint bus, where a number of remote intelligent units act as slaves to a central or host computer. Each slave would be serially addressable from the host and would perform required operations upon being addressed by the host. Based on an MK3873 single-chip microcomputer, the SCU 20 is designed to be such a remote slave device. The capabilities of the SCU 20 and its use in systems applications are examined.

  12. [Some criminological and psychopathologic reflexions about serial crimes].

    Science.gov (United States)

    Romi, Juan Carlos

    2011-01-01

    This article reviews the concept of serial crime, including murder as well as any action for the purpose of inflicting bodily harm upon any person. It characterizes three types of multi-murderers: serial killers, mass murderers, and spree killers. These offenders often have a specific (ritual) behavior that is idiosyncratic and repeated on each crime, which allows the psychological profiling of the murderer. Examples, a psychopathological background, and a description of both their criminal behavior and dynamics are provided for each of these criminals. They are further classified according to their different motivations: psychotic, prophetic or enlightened, pleasure, secondary or pecuniary profits, power or control. Finally, the author shares his personal experience over 20 years in the assessment of sexual offenders.

  13. What's Blood?

    Science.gov (United States)

    ... Body Make Blood? It's not made in a kitchen, but blood has ingredients, just like a recipe. ... these ingredients together and you have blood — an essential part of the circulatory system. Thanks to your ...

  14. Blood typing

    Science.gov (United States)

    ... detect these minor antigens. It is done before transfusions, except in emergency situations. Alternative Names Cross matching; Rh typing; ABO blood typing; Blood group; Anemia - immune hemolytic blood type; ...

  15. Blood smear

    Science.gov (United States)

    ... smear URL of this page: //medlineplus.gov/ency/article/003665.htm Blood smear To use the sharing features on this ... view of cellular parasites Malaria, photomicrograph of cellular parasites Red blood cells, sickle cells Red blood cells, sickle and ...

  16. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, T.L. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); FEI Company, Achtseweg Noord 5, Bldg, 5651 GG, Eindhoven (Netherlands); Kelley, R. [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124 (United States); Winiarski, B. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); FEI Company, Achtseweg Noord 5, Bldg, 5651 GG, Eindhoven (Netherlands); Contreras, L. [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124 (United States); Daly, M.; Gholinia, A.; Burke, M.G. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Withers, P.J., E-mail: P.J.Withers@manchester.ac.uk [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); BP International Centre for Advanced Materials, University of Manchester, Manchester M13 9PL (United Kingdom)

    2016-02-15

    Ga{sup +} Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga{sup +} FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe{sup +} Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC–Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24 h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga{sup +} FIB milling WC–Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60 nA at 30 kV. Xe{sup +} PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. - Highlights: • The uptake of dual beam FIBs has been rapid but long milling times have limited imaged volumes to tens of micron dimensions. • Emerging plasma Xe{sup +} PFIB-SEM technology offers materials removal rates at least 60× greater than conventional Ga{sup +} FIB systems with

  17. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy

    International Nuclear Information System (INIS)

    Burnett, T.L.; Kelley, R.; Winiarski, B.; Contreras, L.; Daly, M.; Gholinia, A.; Burke, M.G.; Withers, P.J.

    2016-01-01

    Ga + Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga + FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe + Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC–Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24 h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga + FIB milling WC–Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60 nA at 30 kV. Xe + PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. - Highlights: • The uptake of dual beam FIBs has been rapid but long milling times have limited imaged volumes to tens of micron dimensions. • Emerging plasma Xe + PFIB-SEM technology offers materials removal rates at least 60× greater than conventional Ga + FIB systems with comparable or less damage. • The

  18. Penerapan Metoda Serial Peripheral Interface (SPI pada Rancang Bangun Data Logger berbasis SD card

    Directory of Open Access Journals (Sweden)

    RATNA SUSANA

    2018-03-01

    Full Text Available ABSTRAK Serial Peripheral Interface (SPI adalah protokol komunikasi yang dapat digunakan sebagai interface komunikasi antara mikrokontroler dengan SD Card. Dengan menerapkan metoda SPI pada data logger berbasis SD Card, maka dapat diketahui karakteristik protokol komunikasi SPI antara mikrokontroler dengan SD Card. SD Card diformat dengan tipe FAT 16, dan data di dalam SD Card berupa sekumpulan paket data sensor yang diambil secara periodik dan disimpan dalam bentuk file dengan format.csv. Berdasarkan format paket data sensor yang dibuat, dapat dihitungwaktu perekaman data yang diperlukan agar kapasitas SD Card terisi penuh oleh data sensor. Hasil penelitian menunjukkan,bahwa metoda SPI yang diterapkan pada penelitian ini memiliki sifat akan melakukan pemeriksaan berulang pada pin MISO terhadap command yang dikirimkan oleh mikrokontroler melalui pin MOSI. Proses read/write data pada SD Card data logger memiliki keberhasilan 100%, karena SD Card telah terinisialisasi dalam mode SPI melalui perintah reset dan init SD Card. Komunikasi ini dapat dilakukan dengan menggunakan crystal 4 Mhz – 20 Mhz. Untuk pengujian konfigurasi SPI, hanya Independent Slave Configuration yang dapat digunakan pada komunikasi SPI dengan 2 SD card sebagai slave. Kata kunci: Serial Peripheral Interface (SPI, Data Logger, SD card, FAT16 ABSTRACT Serial Peripheral Interface (SPI is a communication protocol that can be applied as a communication interface between microcontroller to SD Card. By implementing the SPI method to a data logger based on SD Card, it can be known the characteristics of the SPI communications protocol between microcontroller to SD Card. SD Card formatted in FAT 16 type, and data on the SD Card is the form of sensor data packets collection which be captured periodically and saved in .csv format file. Based on the sensor data packet format is created, it can be calculated recording time data required so that the SD Card capacity completely filled by the

  19. Does the preference of peripheral versus central venous access in peripheral blood stem cell collection/yield change stem cell kinetics in autologous stem cell transplantation?

    Science.gov (United States)

    Dogu, Mehmet Hilmi; Kaya, Ali Hakan; Berber, Ilhami; Sari, İsmail; Tekgündüz, Emre; Erkurt, Mehmet Ali; Iskender, Dicle; Kayıkçı, Ömur; Kuku, Irfan; Kaya, Emin; Keskin, Ali; Altuntaş, Fevzi

    2016-02-01

    Central venous access is often used during apheresis procedure in stem cell collection. The aim of the present study was to evaluate whether central or peripheral venous access has an effect on stem cell yield and the kinetics of the procedure and the product in patients undergoing ASCT after high dose therapy. A total of 327 patients were retrospectively reviewed. The use of peripheral venous access for stem cell yield was significantly more frequent in males compared to females (p = 0.005). Total volume of the product was significantly lower in central venous access group (p = 0.046). As being a less invasive procedure, peripheral venous access can be used for stem cell yield in eligible selected patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Marine mammal health: Organochlorines in blubber, blood and milk of Tursiops truncatus

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, M.L.; Ridgway, S.H. [NCCOSC, San Diego, CA (United States). RDTE Division

    1995-12-31

    Marine mammals are potentially vulnerable organisms for the effects of hazardous man-made chemicals. Organochlorines (OCs) are suspected of causing reproductive failure and immunosuppression which may result in increased susceptibility to infectious disease. High levels of OCs have been found in victims of mass die offs of cetaceans world-wide. To determine baseline values of these organochlorine contaminants found in healthy reproductive dolphins, the authors collected samples of blood, blubber and milk from a population of Tursiops truncatus maintained by the US Navy. These animals are ideal for study because of the availability of relevant biological data which is often lacking in data from wild animals. The Navy dolphins are trained for medical behaviors like blood and milk collection. These behaviors allow them to collect data under controlled conditions preempting errors that occur when collecting similar data on dead and/or wild animals. Using gas chromatography and mass spectrometry (GC/MS) the authors have quantified 10 to 25 PCBs using congener-specific analysis and 19 chlorinated pesticides from microsamples of blubber, blood and milk collected from these animals. The authors also analyzed the fish in the diets of the dolphins. Serial sample collection of milk has allowed us to track the transfer of OCs over the course of lactation. They were also able to correlate OC levels found in blubber, blood and milk. This database should reveal baseline levels relating environmental toxins and marine mammal health to provide a potentially sensitive indicator of pollution and disease in the natural ocean environment and furnish an unparalleled historical pathway toward understanding the effects and consequences of these persistent contaminants and their impact on the marine ecosystem.

  1. Native sulfur/chlorine SAD phasing for serial femtosecond crystallography.

    Science.gov (United States)

    Nakane, Takanori; Song, Changyong; Suzuki, Mamoru; Nango, Eriko; Kobayashi, Jun; Masuda, Tetsuya; Inoue, Shigeyuki; Mizohata, Eiichi; Nakatsu, Toru; Tanaka, Tomoyuki; Tanaka, Rie; Shimamura, Tatsuro; Tono, Kensuke; Joti, Yasumasa; Kameshima, Takashi; Hatsui, Takaki; Yabashi, Makina; Nureki, Osamu; Iwata, So; Sugahara, Michihiro

    2015-12-01

    Serial femtosecond crystallography (SFX) allows structures to be determined with minimal radiation damage. However, phasing native crystals in SFX is not very common. Here, the structure determination of native lysozyme from single-wavelength anomalous diffraction (SAD) by utilizing the anomalous signal of sulfur and chlorine at a wavelength of 1.77 Å is successfully demonstrated. This sulfur SAD method can be applied to a wide range of proteins, which will improve the determination of native crystal structures.

  2. Counterbalancing for serial order carryover effects in experimental condition orders

    OpenAIRE

    Brooks, Joseph L

    2012-01-01

    Reactions of neural, psychological, and social systems are rarely, if ever, independent of previous inputs and states. The potential for serial order carryover effects from one condition to the next in a sequence of experimental trials makes counterbalancing of condition order an essential part of experimental design. Here, a method is proposed for generating counterbalanced sequences for repeated-measures designs including those with multiple observations of each condition on one participant...

  3. A matter of emphasis: Linguistic stress habits modulate serial recall

    OpenAIRE

    Taylor, John C.; Macken, Bill; Jones, Dylan M.

    2014-01-01

    Models of short-term memory for sequential information rely on item-level, feature-based descriptions to account for errors in serial recall. Transposition errors within alternating similar/dissimilar letter sequences derive from interactions between overlapping features. However, in two experiments, we demonstrated that the characteristics of the sequence are what determine the fates of items, rather than the properties ascribed to the items themselves. Performance in alternating sequences i...

  4. Serial MR imaging in Creutzfeldt-Jakob disease

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, A.; Hata, H.; Ohno, M. (Kyushu Rosai Hospital, Kitakyushu (Japan). Dept. of Radiology); Yoshinaga, M.; Shiokawa, O. (Kyushu Rosai Hospital, Kitakyushu (Japan). Stroke Care Unit)

    1991-08-01

    Serial magnetic resonance (MR) imagings of two autopsied patients with Creutzfeldt-Jakob disease (CJD) are presented. Both patients showed a dramatic progression of brain atrophy. The initial MR imagings were, however, interpreted as normal except for localized mild cortical atrophy in one patient. When a normal MR image is obtained in a demented middle-aged or aged patient, CJD may still need to be ruled out: follow up MR imaging may be useful. (orig.).

  5. Serial MR imaging in Creutzfeldt-Jakob disease

    International Nuclear Information System (INIS)

    Uchino, A.; Hata, H.; Ohno, M.; Yoshinaga, M.; Shiokawa, O.

    1991-01-01

    Serial magnetic resonance (MR) imagings of two autopsied patients with Creutzfeldt-Jakob disease (CJD) are presented. Both patients showed a dramatic progression of brain atrophy. The initial MR imagings were, however, interpreted as normal except for localized mild cortical atrophy in one patient. When a normal MR image is obtained in a demented middle-aged or aged patient, CJD may still need to be ruled out: follow up MR imaging may be useful. (orig.)

  6. Which serial killers commit suicide? An exploratory study.

    Science.gov (United States)

    Lester, David; White, John

    2012-11-30

    In a sample of 483 serial killers, 6.2% were documented to have committed suicide. Those who committed suicide were found to come from more dysfunctional homes characterized by more psychiatric disturbance in the parents. The sexual acts involved in the murders by the suicides seemed to be more deviant in some aspects, such as committing more bizarre sexual acts or more often taping the murder. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. High-Yield Purification, Preservation, and Serial Transplantation of Human Satellite Cells

    Directory of Open Access Journals (Sweden)

    Steven M. Garcia

    2018-03-01

    Full Text Available Summary: Investigation of human muscle regeneration requires robust methods to purify and transplant muscle stem and progenitor cells that collectively constitute the human satellite cell (HuSC pool. Existing approaches have yet to make HuSCs widely accessible for researchers, and as a result human muscle stem cell research has advanced slowly. Here, we describe a robust and predictable HuSC purification process that is effective for each human skeletal muscle tested and the development of storage protocols and transplantation models in dystrophin-deficient and wild-type recipients. Enzymatic digestion, magnetic column depletion, and 6-marker flow-cytometric purification enable separation of 104 highly enriched HuSCs per gram of muscle. Cryostorage of HuSCs preserves viability, phenotype, and transplantation potential. Development of enhanced and species-specific transplantation protocols enabled serial HuSC xenotransplantation and recovery. These protocols and models provide an accessible system for basic and translational investigation and clinical development of HuSCs. : Garcia and colleagues report methods for efficient purification of satellite cells from human skeletal muscle. They use their approaches to demonstrate stem cell functions of endogenous satellite cells and to make human satellite cells accessible for sharing among researchers. Keywords: human satellite cell purification, serial transplantation, satellite cell cryopreservation

  8. Effect of impurities and post-experimental purification in SAD phasing with serial femtosecond crystallography data.

    Science.gov (United States)

    Zhang, Tao; Gu, Yuanxin; Fan, Haifu

    2016-06-01

    In serial crystallography (SX) with either an X-ray free-electron laser (XFEL) or synchrotron radiation as the light source, huge numbers of micrometre-sized crystals are used in diffraction data collection. For a SAD experiment using a derivative with introduced heavy atoms, it is difficult to completely exclude crystals of the native protein from the sample. In this paper, simulations were performed to study how the inclusion of native crystals in the derivative sample could affect the result of SAD phasing and how the post-experimental purification proposed by Zhang et al. [(2015), Acta Cryst. D71, 2513-2518] could be used to remove the impurities. A gadolinium derivative of lysozyme and the corresponding native protein were used in the test. Serial femtosecond crystallography (SFX) diffraction snapshots were generated by CrystFEL. SHELXC/D, Phaser, DM, ARP/wARP and REFMAC were used for automatic structure solution. It is shown that a small amount of impurities (snapshots from native crystals) in the set of derivative snapshots can strongly affect the SAD phasing results. On the other hand, post-experimental purification can efficiently remove the impurities, leading to results similar to those from a pure sample.

  9. cDNA Microarray Analysis of Serially Sampled Cervical Cancer Specimens From Patients Treated With Thermochemoradiotherapy

    International Nuclear Information System (INIS)

    Borkamo, Erling Dahl; Schem, Baard-Christian; Fluge, Oystein; Bruland, Ove; Dahl, Olav; Mella, Olav

    2009-01-01

    Purpose: To elucidate changes in gene expression after treatment with regional thermochemoradiotherapy in locally advanced squamous cell cervical cancer. Methods and Materials: Tru-Cut biopsy specimens were serially collected from 16 patients. Microarray gene expression levels before and 24 h after the first and second trimodality treatment sessions were compared. Pathway and network analyses were conducted by use of Ingenuity Pathways Analysis (IPA; Ingenuity Systems, Redwood City, CA). Single gene expressions were analyzed by quantitative real-time reverse transcription-polymerase chain reaction. Results: We detected 53 annotated genes that were differentially expressed after trimodality treatment. Central in the three top networks detected by IPA were interferon alfa, interferon beta, and interferon gamma receptor; nuclear factor κB; and tumor necrosis factor, respectively. These genes encode proteins that are important in regulation cell signaling, proliferation, gene expression, and immune stimulation. Biological processes over-represented among the 53 genes were fibrosis, tumorigenesis, and immune response. Conclusions: Microarrays showed minor changes in gene expression after thermochemoradiotherapy in locally advanced cervical cancer. We detected 53 differentially expressed genes, mainly involved in fibrosis, tumorigenesis, and immune response. A limitation with the use of serial biopsy specimens was low quality of ribonucleic acid from tumors that respond to highly effective therapy. Another 'key limitation' is timing of the post-treatment biopsy, because 24 h may be too late to adequately assess the impact of hyperthermia on gene expression.

  10. Taking serial correlation into account in tests of the mean

    International Nuclear Information System (INIS)

    Zwiers, F.W.; Storch, H. von

    1993-01-01

    The comparison of means derived from samples of noisy data is a standard part of climatology. When the data are not serially correlated the appropriate statistical tool for this task is usually the conventional Student's t-test. However, data frequently are serially correlated in climatological applications with the result that the t-tests in its standard form is not applicable. The usual solution to this problem is to scale the t-statistic by a factor which depends upon the equivalent sample size n e . We show, by means of simulations, that the revised t-test is often conservative (the actual significance level is smaller than the specified significance level) when the equivalent sample size is known. However, in most practical cases the equivalent sample size is not known. Then the test becomes liberal (the actual significance level is greater than the specified significance level). This systematic error becomes small when the true equivalent sample size is large (greater than approximately 30). We re-examine the difficulties inherent in difference of means tests when there is serial dependence. We provide guidelines for the application of the 'usual' t-test and propose two alternative tests which substantially improve upon the 'usual' t-test when samples are small. (orig.)

  11. Cognitive, emotional and social markers of serial murdering.

    Science.gov (United States)

    Angrilli, Alessandro; Sartori, Giuseppe; Donzella, Giovanna

    2013-01-01

    Although criminal psychopathy is starting to be relatively well described, our knowledge of the characteristics and scientific markers of serial murdering is still very poor. A serial killer who murdered more than five people, KT, was administered a battery of standardized tests aimed at measuring neuropsychological impairment and social/emotional cognition deficits. KT exhibited a striking dissociation between a high level of emotional detachment and a low score on the antisocial behavior scale on the Psychopathy Checklist-Revised (PCL-R). The Minnesota Multiphasic Personality Inventory-2 showed a normal pattern with the psychotic triad at borderline level. KT had a high intelligence score and showed almost no impairment in cognitive tests sensitive to frontal lobe dysfunction (Wisconsin Card Sorting Test, Theory of Mind, Tower of London, this latter evidenced a mild impairment in planning performance). In the tests on moral, emotional and social cognition, his patterns of response differed from matched controls and from past reports on criminal psychopaths as, unlike these individuals, KT exhibited normal recognition of fear and a relatively intact knowledge of moral rules but he was impaired in the recognition of anger, embarrassment and conventional social rules. The overall picture of KT suggests that serial killing may be closer to normality than psychopathy defined according to either the DSM IV or the PCL-R, and it would be characterized by a relatively spared moral cognition and selective deficits in social and emotional cognition domains.

  12. DDCMP protocol on a DMA serial-line board

    International Nuclear Information System (INIS)

    Hunt, D.N.; Kessler, G.C.

    1982-01-01

    The Nuclear Chemistry Division of Lawrence Livermore National Laboratory is in the midst of an upgrade to their radiation counting facility. The result of this upgrade wil be a computer-based data acquisition network, the Nuclear Chemistry Counting Facility Network (NCCF-NET). This network will consist of forty dedicated LSI-11/2 based controllers, ten interactive LSI-11/23 based workstations and a VAX-11/750 central node for data reduction and storage. One of the data acquisition instruments used in this network is a Nuclear Data pulse-height analyzer, the ND66L. This analyzer communicates to a host system over a 9600-baud serial line, using the DDCMP link level protocol. In order to relieve the host computer from the overhead of handling the DDCMP protocol, an in-house designed DMA serial line board was implemented to communicate with the ND66L. The hardware used and its environment will be duscussed along with the design and implementation of the firmware, which implements the serial DDCMP link

  13. A matter of emphasis: Linguistic stress habits modulate serial recall.

    Science.gov (United States)

    Taylor, John C; Macken, Bill; Jones, Dylan M

    2015-04-01

    Models of short-term memory for sequential information rely on item-level, feature-based descriptions to account for errors in serial recall. Transposition errors within alternating similar/dissimilar letter sequences derive from interactions between overlapping features. However, in two experiments, we demonstrated that the characteristics of the sequence are what determine the fates of items, rather than the properties ascribed to the items themselves. Performance in alternating sequences is determined by the way that the sequences themselves induce particular prosodic rehearsal patterns, and not by the nature of the items per se. In a serial recall task, the shapes of the canonical "saw-tooth" serial position curves and transposition error probabilities at successive input-output distances were modulated by subvocal rehearsal strategies, despite all item-based parameters being held constant. We replicated this finding using nonalternating lists, thus demonstrating that transpositions are substantially influenced by prosodic features-such as stress-that emerge during subvocal rehearsal.

  14. The Effect of Concurrent Semantic Categorization on Delayed Serial Recall

    Science.gov (United States)

    Acheson, Daniel J.; MacDonald, Maryellen C.; Postle, Bradley R.

    2010-01-01

    The influence of semantic processing on the serial ordering of items in short-term memory was explored using a novel dual-task paradigm. Subjects engaged in two picture judgment tasks while simultaneously performing delayed serial recall. List material varied in the presence of phonological overlap (Experiments 1 and 2) and in semantic content (concrete words in Experiment 1 and 3; nonwords in Experiments 2 and 3). Picture judgments varied in the extent to which they required accessing visual semantic information (i.e., semantic categorization and line orientation judgments). Results showed that, relative to line orientation judgments, engaging in semantic categorization judgments increased the proportion of item ordering errors for concrete lists but did not affect error proportions for nonword lists. Furthermore, although more ordering errors were observed for phonologically similar relative to dissimilar lists, no interactions were observed between the phonological overlap and picture judgment task manipulations. These results thus demonstrate that lexical-semantic representations can affect the serial ordering of items in short-term memory. Furthermore, the dual-task paradigm provides a new method for examining when and how semantic representations affect memory performance. PMID:21058880

  15. Voltage balancing strategies for serial connection of microbial fuel cells

    Science.gov (United States)

    Khaled, Firas; Ondel, Olivier; Allard, Bruno; Buret, François

    2015-07-01

    The microbial fuel cell (MFC) converts electrochemically organic matter into electricity by means of metabolisms of bacteria. The MFC power output is limited by low voltage and low current characteristics in the range of microwatts or milliwatts per litre. In order to produce a sufficient voltage level (>1.5 V) and sufficient power to supply real applications such as autonomous sensors, it is necessary to either scale-up one single unit or to connect multiple units together. Many topologies of connection are possible as the serial association to improve the output voltage, or the parallel connection to improve the output current or the series/parallel connection to step-up both voltage and current. The association of MFCs in series is a solution to increase the voltage to an acceptable value and to mutualize the unit's output power. The serial association of a large number of MFCs presents several issues. The first one is the hydraulic coupling among MFCs when they share the same substrate. The second one is the dispersion between generators that lead to a non-optimal stack efficiency because the maximum power point (MPP) operation of all MFCs is not permitted. Voltage balancing is a solution to compensate non-uniformities towards MPP. This paper presents solutions to improve the efficiency of a stack of serially connected MFCs through a voltage-balancing circuit. Contribution to the topical issue "Electrical Engineering Symposium (SGE 2014)", edited by Adel Razek

  16. Evidence for spontaneous serial refreshing in verbal working memory?

    Science.gov (United States)

    Vergauwe, Evie; Langerock, Naomi; Cowan, Nelson

    2018-04-01

    Working memory (WM) keeps information temporarily accessible for ongoing cognition. One proposed mechanism to keep information active in WM is refreshing. This mechanism is assumed to operate by bringing memory items into the focus of attention, thereby serially refreshing the content of WM. We report two experiments in which we examine evidence for the spontaneous occurrence of serial refreshing in verbal WM. Participants had to remember series of red letters, while black probe letters were presented between these memory items, with each probe to be judged present in or absent from the list presented so far, as quickly as possible (i.e., the probe-span task). Response times to the probes were used to infer the status of the representations in WM and, in particular, to examine whether the content of the focus of attention changed over time, as would be expected if serial refreshing occurs spontaneously during inter-item pauses. In sharp contrast with this hypothesis, our results indicate that the last-presented memory item remained in the focus of attention during the inter-item pauses of the probe-span task. We discuss how these findings help to define the boundary conditions of spontaneous refreshing of verbal material in WM, and discuss implications for verbal WM maintenance and forgetting.

  17. Efficient multitasking: parallel versus serial processing of multiple tasks.

    Science.gov (United States)

    Fischer, Rico; Plessow, Franziska

    2015-01-01

    In the context of performance optimizations in multitasking, a central debate has unfolded in multitasking research around whether cognitive processes related to different tasks proceed only sequentially (one at a time), or can operate in parallel (simultaneously). This review features a discussion of theoretical considerations and empirical evidence regarding parallel versus serial task processing in multitasking. In addition, we highlight how methodological differences and theoretical conceptions determine the extent to which parallel processing in multitasking can be detected, to guide their employment in future research. Parallel and serial processing of multiple tasks are not mutually exclusive. Therefore, questions focusing exclusively on either task-processing mode are too simplified. We review empirical evidence and demonstrate that shifting between more parallel and more serial task processing critically depends on the conditions under which multiple tasks are performed. We conclude that efficient multitasking is reflected by the ability of individuals to adjust multitasking performance to environmental demands by flexibly shifting between different processing strategies of multiple task-component scheduling.

  18. Simple measuring rod method for the coaxiality of serial holes

    Science.gov (United States)

    Wang, Lei; Yang, Tongyu; Wang, Zhong; Ji, Yuchen; Liu, Changjie; Fu, Luhua

    2017-11-01

    Aiming at the rapid coaxiality measurement of serial hole part with a small diameter, a coaxiality measuring rod for each layer hole with a single LDS (laser displacement sensor) is proposed. This method does not require the rotation angle information of the rod, and the coaxiality of serial holes can be calculated from the measured values of LDSs after randomly rotating the measuring rod several times. With the mathematical model of the coaxiality measuring rod, each factor affecting the accuracy of coaxiality measurement is analyzed by simulation, and the installation accuracy requirements of the measuring rod and LDSs are presented. In the tolerance of a certain installation error of the measuring rod, the relative center of the hole is calculated by setting the over-determined nonlinear equations of the fitting circles of the multi-layer holes. In experiment, coaxiality measurement accuracy is realized by a 16 μm precision LDS, and the validity of the measurement method is verified. The manufacture and measurement requirements of the coaxiality measuring rod are low, by changing the position of LDSs in the measuring rod, the serial holes with different sizes and numbers can be measured. The rapid coaxiality measurement of parts can be easily implemented in industrial sites.

  19. A network-based Macintosh serial host interface program

    International Nuclear Information System (INIS)

    Wight, J.

    1991-03-01

    A program has been written for the Apple Macintosh to replace conventional host RS232 terminals with customizable user interfaces. Serial port NuBus cards in the Macintosh allow many simultaneous sessions to be maintained. A powerful system is attained by connecting multiple Macintoshes on a network, each running this program. Each is then able to share incoming data from any of its serial ports with any other Macintosh, as well as accept data from any other Macintosh for output to any of its serial ports. The program has been used to eliminate multiple host terminals, modernize the user interface, and to centralize operation of a complex control system. Minimal changes to host software have been required. By making extensive use of Macintosh resources, the same executable code serves in a variety of roles. An object oriented C language with a class library made the development straightforward and easy to modify. This program is used to control a 2 MW neutral beam system on the DIII-D magnetic fusion tokamak. 7 figs

  20. The neural signature of emotional memories in serial crimes.

    Science.gov (United States)

    Chassy, Philippe

    2017-10-01

    Neural plasticity is the process whereby semantic information and emotional responses are stored in neural networks. It is hypothesized that the neural networks built over time to encode the sexual fantasies that motivate serial killers to act should display a unique, detectable activation pattern. The pathological neural watermark hypothesis posits that such networks comprise activation of brain sites that reflect four cognitive components: autobiographical memory, sexual arousal, aggression, and control over aggression. The neural sites performing these cognitive functions have been successfully identified by previous research. The key findings are reviewed to hypothesise the typical pattern of activity that serial killers should display. Through the integration of biological findings into one framework, the neural approach proposed in this paper is in stark contrast with the many theories accounting for serial killers that offer non-medical taxonomies. The pathological neural watermark hypothesis offers a new framework to understand and detect deviant individuals. The technical and legal issues are briefly discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Riboflavin and ultraviolet light reduce the infectivity of Babesia microti in whole blood.

    Science.gov (United States)

    Tonnetti, Laura; Thorp, Aaron M; Reddy, Heather L; Keil, Shawn D; Goodrich, Raymond P; Leiby, David A

    2013-04-01

    Babesia microti is the parasite most frequently transmitted by blood transfusion in the United States. Previous work demonstrated the efficacy of riboflavin (RB) and ultraviolet (UV) light to inactivate B.microti in apheresis plasma and platelet units. In this study we investigated the effectiveness of RB and UV light to reduce the levels of B.microti in whole blood (WB). WB units were spiked with B. microti-infected hamster blood. Spearman-Karber methods were used to calculate infectivity of each sample in terms of hamster infectious dose 50% (HID50 ) value. After RB addition, the units were illuminated with 80 J/mLRBC UV light. Two samples were collected: one before illumination and one after illumination. The samples were serially diluted and dilutions injected into a group of five naive hamsters. Four weeks postinoculation (PI), blood was collected from the animals and evaluated by microscopic observation. One pilot study showed a good dose response in the animals and demonstrated that sample infectivity could be calculated in terms of an HID50 . Three additional replicates were performed in the same manner as the pilot study, but with fewer dilutions. Infectivity values were consistent between the experiments and were used to calculate log reduction. The posttreatment reduction of B. microti for all the experiments was more than 5 log. The data collected indicate that use of RB and UV is able to decrease the parasite load in WB units thus reducing the risk of transfusion-transmitted B. microti from blood components containing B. microti-infected RBCs. © 2012 American Association of Blood Banks.

  2. Blood Culture (For Parents)

    Science.gov (United States)

    ... Metabolic Panel (BMP) Blood Test: Complete Blood Count Basic Blood Chemistry Tests Getting a Blood Test (Video) Blood Test: Basic Metabolic Panel Blood Test: Comprehensive Metabolic Panel Blood ...

  3. The Integrity of the Corpus Callosum Mitigates the Impact of Blood Pressure on the Ventral Attention Network and Information Processing Speed in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Tatia M. C. Lee

    2017-04-01

    Full Text Available Hypertension is a risk factor for cognitive impairment in older age. However, evidence of the neural basis of the relationship between the deterioration of cognitive function and elevated blood pressure is sparse. Based on previous research, we speculate that variations in brain connectivity are closely related to elevated blood pressure even before the onset of clinical conditions and apparent cognitive decline in individuals over 60 years of age. Forty cognitively healthy adults were recruited. Each received a blood pressure test before and after the cognitive assessment in various domains. Diffusion tensor imaging (DTI and resting-state functional magnetic resonance imaging (rsfMRI data were collected. Our findings confirm that elevated blood pressure is associated with brain connectivity variations in cognitively healthy individuals. The integrity of the splenium of the corpus callosum is closely related to individual differences in systolic blood pressure. In particular, elevated systolic blood pressure is related to resting-state ventral attention network (VAN and information processing speed. Serial mediation analyses have further revealed that lower integrity of the splenium statistically predicts elevated systolic blood pressure, which in turn predicts weakened functional connectivity (FC within the VAN and eventually poorer processing speed. The current study sheds light on how neural correlates are involved in the impact of elevated blood pressure on cognitive functioning.

  4. Effects of blood contamination of cerebrospinal fluid on results of indirect fluorescent antibody tests for detection of antibodies against Sarcocystis neurona and Neospora hughesi.

    Science.gov (United States)

    Finno, Carrie J; Packham, Andrea E; David Wilson, W; Gardner, Ian A; Conrad, Patricia A; Pusterla, Nicola

    2007-05-01

    The purpose of this study was to determine the effect of blood contamination of cerebrospinal fluid (CSF) on the results of indirect fluorescent antibody tests (IFATs) for Sarcocystis neurona and Neospora hughesi. The in vitro study used antibody-negative CSF collected from non-neurologic horses immediately after euthanasia and blood samples from 40 healthy horses that had a range of IFAT antibody titers against S. neurona and N. hughesi. Serial dilutions of whole blood were made in seronegative CSF to generate blood-contaminated CSF with red blood cell (RBC) concentrations ranging from 10 to 100,000 RBCs/microl. The blood-contaminated CSF samples were then tested for antibodies against both pathogens using IFAT. Blood contamination of CSF had no detectable effect on IFAT results for S. neurona or N. hughesi at any serologic titer when the RBC concentration in CSF was or=5) for S. neurona and N. hughesi were detected only when the corresponding serum titers were >or=160 and >or=80, respectively. The IFAT performed on CSF is reliable for testing horses for equine protozoal myeloencephalitis caused by S. neurona or N. hughesi, even when blood contamination causes the RBC concentration in CSF to be up to 10,000 RBCs/microl.

  5. A Snapshot of Serial Rape: An Investigation of Criminal Sophistication and Use of Force on Victim Injury and Severity of the Assault.

    Science.gov (United States)

    de Heer, Brooke

    2016-02-01

    Prior research on rapes reported to law enforcement has identified criminal sophistication and the use of force against the victim as possible unique identifiers to serial rape versus one-time rape. This study sought to contribute to the current literature on reported serial rape by investigating how the level of criminal sophistication of the rapist and use of force used were associated with two important outcomes of rape: victim injury and overall severity of the assault. In addition, it was evaluated whether rapist and victim ethnicity affected these relationships. A nation-wide sample of serial rape cases reported to law enforcement collected by the Federal Bureau of Investigation (FBI) was analyzed (108 rapists, 543 victims). Results indicated that serial rapists typically used a limited amount of force against the victim and displayed a high degree of criminal sophistication. In addition, the more criminally sophisticated the perpetrator was, the more sexual acts he performed on his victim. Finally, rapes between a White rapist and White victim were found to exhibit higher levels of criminal sophistication and were more severe in terms of number and types of sexual acts committed. These findings provide a more in-depth understanding of serial rape that can inform both academics and practitioners in the field about contributors to victim injury and severity of the assault. © The Author(s) 2014.

  6. Serial measurements of serum human placental lactogen (hPL) and serial ultrasound examinations in the evaluation of fetal growth

    DEFF Research Database (Denmark)

    Sørensen, Steen; von Tabouillot, D; Schioler, V

    2000-01-01

    Serial serum hPL measurements and serial ultrasound fetometry were compared in the evaluation of fetal growth by relating these two parameters to size at birth and to clinical factors known to influence size at birth. The data were from a prospective study of 1000 consecutive pregnant women...... considered to be at risk for fetal growth retardation with retrospective analysis. Serum hPL was measured by radioimmunoassay and fetal weight estimated by ultrasound every 3 weeks during the last trimester. hPL values were expressed as multiples of the median (MoM) and linear regression analysis of the h......PL MoM values was carried out for each pregnancy to find the slope of the line (hPL-slope); at least 3 serum hPL values were required. The estimated fetal weight and weight-for-age at birth was expressed in Z-scores. The individual intrauterine growth velocity was calculated by regression analysis...

  7. Creating Complex Repository Collections, Such as Journals, with Manakin

    Science.gov (United States)

    Koenig, Jack; Mikeal, Adam

    2010-01-01

    Purpose: The purpose of this paper is to report on a devised method of collection organisation within a DSpace repository using a Manakin theme and descriptive metadata. Design/methodology/approach: Using a Manakin theme, a user interface for a repository collection containing the contents of a serial was created to divide the collection into…

  8. Serial studies of cerebral blood flow using 99Tcm-HMPAO

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Lassen, N A

    1987-01-01

    -HMPAO was measured after i.v. injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6 to 10 mm (HR) and 15 to 20 (LR). 99Tcm-HMPAO images showed close resemblance to xenon-133 CBF tomograms. Only about 20% of the (decay corrected) brain counts were lost during...

  9. The Influence of Serial Carbohydrate Mouth Rinsing on Power Output during a Cycle Sprint.

    Science.gov (United States)

    Phillips, Shaun M; Findlay, Scott; Kavaliauskas, Mykolas; Grant, Marie Clare

    2014-05-01

    The objective of the study was to investigate the influence of serial administration of a carbohydrate (CHO) mouth rinse on performance, metabolic and perceptual responses during a cycle sprint. Twelve physically active males (mean (± SD) age: 23.1 (3.0) years, height: 1.83 (0.07) m, body mass (BM): 86.3 (13.5) kg) completed the following mouth rinse trials in a randomized, counterbalanced, double-blind fashion; 1. 8 x 5 second rinses with a 25 ml CHO (6% w/v maltodextrin) solution, 2. 8 x 5 second rinses with a 25 ml placebo (PLA) solution. Following mouth rinse administration, participants completed a 30 second sprint on a cycle ergometer against a 0.075 g·kg(-1) BM resistance. Eight participants achieved a greater peak power output (PPO) in the CHO trial, resulting in a significantly greater PPO compared with PLA (13.51 ± 2.19 vs. 13.20 ± 2.14 W·kg(-1), p 0.05). No significant between-trials difference was reported for fatigue index, perceived exertion, arousal and nausea levels, or blood lactate and glucose concentrations. Serial administration of a CHO mouth rinse may significantly improve PPO during a cycle sprint. This improvement appears confined to the first 5 seconds of the sprint, and may come at a greater relative cost for the remainder of the sprint. Key pointsThe paper demonstrates that repeated administration of a carbohydrate mouth rinse can significantly improve peak power output during a single 30 second cycle sprint.The ergogenic effect of the carbohydrate mouth rinse may relate to the duration of exposure of the oral cavity to the mouth rinse, and associated greater stimulation of oral carbohydrate receptors.The significant increase in peak power output with the carbohydrate mouth rinse may come at a relative cost for the remainder of the sprint, evidenced by non-significantly lower mean power output and a greater fatigue index in the carbohydrate vs. placebo trial.Serial administration of a carbohydrate mouth rinse may be beneficial for

  10. Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans

    International Nuclear Information System (INIS)

    Freedman, Nanette M.T.; Sundaram, Senthil K.; Kurdziel, Karen; Carrasquillo, Jorge A.; Whatley, Millie; Carson, Joann M.; Sellers, David; Libutti, Steven K.; Yang, James C.; Bacharach, Stephen L.

    2003-01-01

    The standardized uptake value (SUV) and the slope of the Patlak plot (K) have both been proposed as indices to monitor the progress of disease during cancer therapy. Although a good correlation has been reported between SUV and K, they are not equivalent, and may not be equally affected by metabolic changes occurring during disease progression or therapy. We wished to compare changes in tumor SUV with changes in K during serial positron emission tomography (PET) scans for monitoring therapy. Thirteen patients enrolled in a protocol to treat renal cell carcinoma metastases were studied. Serial dynamic fluorodeoxyglucose (FDG) PET scans and computed tomography (CT) and magnetic resonance (MR) scans were performed once prior to treatment, once at 36±2 days after the start of treatment, and (in 7/13 subjects, 16/27 lesions) a third time at 92±9 days after the start of treatment. This resulted in a total of 33 scans, and 70 tumor Patlak and SUV values (one value for each lesion at each time point). SUV and K were measured over one to four predefined tumors/patient at each time point. The input function was obtained from regions of interest over the heart, combined, if necessary, with late blood samples. Over all tumors and scans, SUV and K correlated well (r=0.97, P<0.0001). However, change in SUV with treatment over all tumor scan pairs was much less well correlated with the corresponding change in K (r=0.73, P<0.0001). The absolute difference in % change was outside the 95% confidence limits expected from previous variability studies in 6 of 43 pairs of tumor scans, and greater than 50% in 2 of 43 tumor scan pairs. In four of the six cases, the two indices predicted opposing therapeutic outcomes. Similar results were obtained for SUV normalized by body weight or body surface area and for SUVs using mean or maximum count. Changes in CT and MR tumor cross-product dimensions correlated poorly with each other (r=0.47, P=NS), and so could not be used to determine the

  11. Learning of serial digits leads to frontal activation in functional MR imaging.

    Science.gov (United States)

    Karakaş, Hakki Muammer; Karakaş, Sirel

    2006-03-01

    Clinical studies have shown that performance on the serial digit learning test (SDLT) is dependent upon the mesial temporal lobes, which are responsible for learning and its consolidation. However, an effective SDLT performance is also dependent upon sequencing, temporal ordering, and the utilization of mnemonic strategies. All of these processes are among the functions of the frontal lobes; in spite of this, the relationship between SDLT performance and the frontal lobes has not been demonstrated with previously used mapping techniques. The aim of this study was to investigate the areas of the brain that are activated by SDLT performance. Ten healthy, right handed volunteers (mean age, 20.1 years; SD: 3.3) who had 12 years of education were studied with a 1.0 T MR imaging scanner. BOLD (blood oxygen level dependent) contrast and a modified SDLT were used. Activated loci were automatically mapped using a proportional grid. In learning, the most consistent activation was observed in B-a-7 of the right (80%) and the left hemispheres (50%). In recall, the most consistent activation was observed in B-a-7 of the right hemisphere (60%). Activations were observed in 2.5+/-0.97 Talairach volumes in learning, whereas they encompassed 1.7+/-0.95 volumes in recall. The difference between both phases (learning and recall) regarding total activated volume was significant (p SDLT performance was not related to learning or to recall, but to a function that is common to both of these cognitive processes. A candidate for this common factor may be the executive functions, which also include serial position processing and temporal ordering.

  12. Bilinear common spatial pattern for single-trial ERP-based rapid serial visual presentation triage

    Science.gov (United States)

    Yu, K.; Shen, K.; Shao, S.; Ng, W. C.; Li, X.

    2012-08-01

    Common spatial pattern (CSP) analysis is a useful tool for the feature extraction of event-related potentials (ERP). However, CSP is essentially time invariant, and thus unable to exploit the temporal information of ERP. This paper proposes a variant of CSP, namely bilinear common spatial pattern (BCSP), which is capable of accommodating both spatial and temporal information. BCSP generalizes CSP through iteratively optimizing bilinear filters. These bilinear filters constitute a spatio-temporal subspace in which the separation between two conditions is maximized. The method is unique in the sense that it is mathematically intuitive and simple, as all the bilinear filters are obtained by maximizing the power ratio as CSP does. The proposed method was evaluated on 20 subjects’ ERP data collected in rapid serial visual presentation triage experiments. The results show that BCSP achieved significantly higher average test accuracy (12.3% higher, p < 0.001).

  13. Theory of Visual Attention (TVA) applied to mice in the 5-choice serial reaction time task

    DEFF Research Database (Denmark)

    Fitzpatrick, C. M.; Caballero-Puntiverio, M.; Gether, U.

    2017-01-01

    Rationale The 5-choice serial reaction time task (5-CSRTT) is widely used to measure rodent attentional functions. In humans, many attention studies in healthy and clinical populations have used testing based on Bundesen’s Theory of Visual Attention (TVA) to estimate visual processing speeds...... on an individual level. Scopolamine HBr dose-dependently reduced 5-CSRTT attentional performance while also increasing reward collection latency at the highest dose. Upon TVA modelling, scopolamine HBr significantly reduced visual processing speed at both doses, while having less pronounced effects on visual...... modelled using a new three-parameter version of TVA to obtain estimates of visual processing speeds, visual thresholds and motor response baselines in each mouse. Results The parameter estimates for each animal were reliable across sessions, showing that the data were stable enough to support analysis...

  14. Feasibility of Serial Saliva Collection for Surveillance of Swimming-Associated Illness

    Science.gov (United States)

    BACKGROUND. The symptoms of many swimming-associated illnesses overlap, and clinical diagnoses often require serum or stool samples. Therefore, it has been difficult to determine the contributions of different etiologic agents to swimming-associated illness. OBJECTIVES. We collec...

  15. Word-serial Architectures for Filtering and Variable Rate Decimation

    Directory of Open Access Journals (Sweden)

    Eugene Grayver

    2002-01-01

    Full Text Available A new flexible architecture is proposed for word-serial filtering and variable rate decimation/interpolation. The architecture is targeted for low power applications requiring medium to low data rate and is ideally suited for implementation on either an ASIC or an FPGA. It combines the small size and low power of an ASIC with the programmability and flexibility of a DSP. An efficient memory addressing scheme eliminates the need for power hungry shift registers and allows full reconfiguration. The decimation ratio, filter length and filter coefficients can all be changed in real time. The architecture takes advantage of coefficient symmetries in linear phase filters and in polyphase components.

  16. Diffusion thermopower of a serial double quantum dot

    International Nuclear Information System (INIS)

    Thierschmann, H; Henke, M; Knorr, J; Maier, L; Buhmann, H; Molenkamp, L W; Heyn, C; Hansen, W

    2013-01-01

    We have experimentally studied the diffusion thermopower of a serial double quantum dot, defined electrostatically in a GaAs/AlGaAs heterostructure. We present the thermopower stability diagram for a temperature difference ΔT = (20 ± 10) mK across the device and find a maximum thermovoltage signal of several μV in the vicinity of the triple points. Along a constant energy axis in this regime, the data show a characteristic pattern which is in agreement with Mott's relation and can be well understood within a model of sequential transport. (paper)

  17. Hi-speed versatile serial crate controller for CAMAC

    International Nuclear Information System (INIS)

    Horelick, D.

    1984-10-01

    A serial crate controller, primarily for use in the SLC CAMAC control system, has been designed, and has been in use for about 2 years. The design supports a party line approach, with up to 16 crates on a single twisted pair for data transfers, plus another pair for prompt L response. The bit rate is 5 megabits/s, and complete transaction times of about 10 μs are achieved for 16-bit data transfers over cables up to 1000 feet long. One of the primary objects of the design was simplicity - there are approximately 60 chips in the two-board unit

  18. Lean buffering in serial production lines with Bernoulli machines

    Directory of Open Access Journals (Sweden)

    A. B. Hu

    2006-01-01

    Full Text Available Lean buffering is the smallest buffer capacity necessary to ensure the desired production rate of a manufacturing system. In this paper, analytical methods for selecting lean buffering in serial production lines are developed under the assumption that the machines obey the Bernoulli reliability model. Both closed-form expressions and recursive approaches are investigated. The cases of identical and nonidentical machines are analyzed. Results obtained can be useful for production line designers and production managers to maintain the required production rate with the smallest possible inventories.

  19. Key Conditions for Successful Serial Entrepreneurship in Healthcare.

    Science.gov (United States)

    Piron, Cameron

    2017-01-01

    As a serial entrepreneur in the medical device industry, the author embraces Snowdon's (2017) effort to create and stimulate dialogue among experts in health system innovation in an effort to define and support Canada's innovation agenda. In this paper, he outlines some of the attributes and skills that companies need to launch their products and scale their companies. He also identifies the main conditions of an innovation ecosystem that create the necessary infrastructure to enable and support highly successful companies while allowing them to accelerate their growth.

  20. Serial computed tomography findings in Creutzfeldt-Jakob disease

    International Nuclear Information System (INIS)

    Schlenska, G.K.; Walter, G.F.

    1989-01-01

    Serial CT investigations of 3 patients with histologically confirmed Creutzfeldt-Jakob disease revealed persisting slight brain atrophy to progressive extreme atrophy corresponding to the absolute, not the individual duration of illness. No correlation was observed between CT findings and the patients condition or electroencephalographic results. In one case with a duration of about 16 months and a terminal brain weight of 750 g a massive bilateral, later unilateral subdural hygroma appeared which probably was caused by retraction of the brain showing an enormous atrophy. (orig.)

  1. Serial computed tomography findings in Creutzfeldt-Jakob disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlenska, G.K.; Walter, G.F.

    1989-09-01

    Serial CT investigations of 3 patients with histologically confirmed Creutzfeldt-Jakob disease revealed persisting slight brain atrophy to progressive extreme atrophy corresponding to the absolute, not the individual duration of illness. No correlation was observed between CT findings and the patients condition or electroencephalographic results. In one case with a duration of about 16 months and a terminal brain weight of 750 g a massive bilateral, later unilateral subdural hygroma appeared which probably was caused by retraction of the brain showing an enormous atrophy. (orig.).

  2. Freeform Optics: current challenges for future serial production

    Science.gov (United States)

    Schindler, C.; Köhler, T.; Roth, E.

    2017-10-01

    One of the major developments in optics industry recently is the commercial manufacturing of freeform surfaces for optical mid- and high performance systems. The loss of limitation on rotational symmetry enables completely new optical design solutions - but causes completely new challenges for the manufacturer too. Adapting the serial production from radial-symmetric to freeform optics cannot be done just by the extension of machine capabilities and software for every process step. New solutions for conventional optics productions or completely new process chains are necessary.

  3. Long-distance configuration of FPGA based on serial communication

    International Nuclear Information System (INIS)

    Liu Xiang; Song Kezhu; Zhang Sifeng

    2010-01-01

    To solve FPGA configuration in some nuclear electronics, which works in radioactivity environment, the article introduces a way of long-distance configuration with PC and CPLD, based on serial communication. Taking CYCLONE series FPGA and EPCS configuration chip from ALTERA for example, and using the AS configuration mode, we described our design from the aspects of basic theory, hardware connection, software function and communication protocol. With this design, we could configure several FPGAs in the distance of 100 meters, or we could configure on FPGA in the distance of 150 meters. (authors)

  4. The essential guide to Serial ATA and SATA express

    CERN Document Server

    Deming, David A

    2014-01-01

    Used in laptop and desktop computers, low-end servers, and mobile devices, Serial ATA (Advance Technology Attachment), or SATA, is the pervasive disk storage technology in use today. SATA has also penetrated the enterprise computing environment by adding hardware components for fail-over, extending command processing capabilities, and increasing device performance and link speeds. If you work in a data center or manage your company's storage resources, you will likely encounter storage solutions that require SATA software or hardware.In this book, leading storage networking technologist David

  5. POSSIBILITIES OF INCREASING EFFICIENCY WITHIN SERIAL PRODUCTION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    CODRUŢA DURA

    2010-01-01

    Full Text Available Under the impact of transition to the new post-industrial society, massproduction recently faced the most numerous difficulties. They are caused by turbulences in theexternal environment in which companies operate, manifested in particular by enhancing thedynamism of markets and by deep changes in the structure of consumers’ demands. In thiscontext, specialized literature records the concerns for increasing the efficiency and flexibilityof products, elements involving radical changes of management and manufacturingtechnologies methods. Given these issues, the paper approaches two separate ways to improvethe management of serial production: increasing economic efficiency by optimizing the size ofbatches and flexible production systems by implementing techniques to reduce the change-overtime.

  6. Multidisciplinary team review of best practices for collection and handling of blood cultures to determine effective interventions for increasing the yield of true-positive bacteremias, reducing contamination, and eliminating false-positive central line-associated bloodstream infections.

    Science.gov (United States)

    Garcia, Robert A; Spitzer, Eric D; Beaudry, Josephine; Beck, Cindy; Diblasi, Regina; Gilleeny-Blabac, Michelle; Haugaard, Carol; Heuschneider, Stacy; Kranz, Barbara P; McLean, Karen; Morales, Katherine L; Owens, Susan; Paciella, Mary E; Torregrosa, Edwin

    2015-11-01

    A literature search was conducted using keywords for articles published in English from January 1990 to March 2015. Using criteria related to blood culture collection and handling, the search yielded 101 articles. References used also included Microbiology Laboratory standards, guidelines, and textbook information. The literature identified diverse and complex issues surrounding blood culture practices, including the impact of false-positive results, laboratory definition of contamination, effect on central line-associated bloodstream infection (CLABSI) reporting, indications for collecting blood cultures, drawing from venipuncture sites versus intravascular catheters, selection of antiseptics, use of needleless connectors, inoculation of blood culture bottles, and optimizing program management in emergency departments, education, and implementation of bundled practice initiatives. Hospitals should optimize best practice in the collection, handling, and management of blood culture specimens, an often overlooked but essential component in providing optimal care of patients in all settings and populations, reducing financial burdens, and increasing the accuracy of reportable CLABSI. Although universal concepts exist in blood culture practices, some issues require further research to determine benefit. Institutions undertaking a review of their blood culture programs are encouraged to use a checklist that addresses elements that encompass the research contained in this review. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Attenuation of Red Blood Cell Storage Lesions with Vitamin C

    Directory of Open Access Journals (Sweden)

    Kimberly Sanford

    2017-07-01

    Full Text Available Stored red blood cells (RBCs undergo oxidative stress that induces deleterious metabolic, structural, biochemical, and molecular changes collectively referred to as “storage lesions”. We hypothesized that vitamin C (VitC, reduced or oxidized would reduce red cell storage lesions, thus prolonging their storage duration. Whole-blood-derived, leuko-reduced, SAGM (saline-adenine-glucose-mannitol-preserved RBC concentrates were equally divided into four pediatric storage bags and the following additions made: (1 saline (saline; (2 0.3 mmol/L reduced VitC (Lo VitC; (3 3 mmol/L reduced VitC (Hi VitC; or (4 0.3 mmol/L oxidized VitC (dehydroascorbic acid, DHA as final concentrations. Biochemical and rheological parameters were serially assessed at baseline (prior to supplementation and Days 7, 21, 42, and 56 for RBC VitC concentration, pH, osmotic fragility by mechanical fragility index, and percent hemolysis, LDH release, glutathione depletion, RBC membrane integrity by scanning electron microscopy, and Western blot for β-spectrin. VitC exposure (reduced and oxidized significantly increased RBC antioxidant status with varying dynamics and produced trends in reduction in osmotic fragility and increases in membrane integrity. Conclusion: VitC partially protects RBC from oxidative changes during storage. Combining VitC with other antioxidants has the potential to improve long-term storage of RBC.

  8. Implementation of Bluetooth serial port based profiles in embedded systems

    Science.gov (United States)

    Liu, Guanglei; Qiu, Zhengding; Wang, Quanping; Gao, Qiang

    2001-10-01

    Bluetooth is a new short-range wireless communication technology developing rapidly in recent years. Bluetooth software architecture consists of stack and profiles. Serial Port Profile (SPP) is an underlying profile that emulates RS232 serial cable connections between two peer devices. Based on SPP, Dial-up Networking (DUN) Profile establishes PPP connection with remote dial-up server, Fax Profile realizes document facsimile function and LAN Access Profile (LAP) provides local area network access service. When it comes to their implementation in embedded systems, there are several challenges such as memory consumption, code efficiency, code reliability, and code portability onto different OS and hardware platforms to be attacked. In this paper, we propose integrated software architecture after discussing the great similarities shared among the three SPP based profiles. Then implementation of the architecture is given, in which OS-dependent and OS-independent parts are clearly separated. Profile interfaces with stack and OS are specified respectively so that the three profiles as a whole can be ported onto various software and hardware platforms easily. As a result, policy of transplanting our implementation onto different platforms is addressed at the end of the paper.

  9. Rethinking Conceptual Definitions of the Criminal Career and Serial Criminality.

    Science.gov (United States)

    Edelstein, Arnon

    2016-01-01

    Since Cesare Lombroso's days, criminology seeks to define, explain, and categorize the various types of criminals, their behaviors, and motives. This aim has theoretical as well as policy-related implications. One of the important areas in criminological thinking focuses chiefly on recidivist offenders who perform large numbers of crimes and/or commit the most dangerous crimes in society (rape, murder, arson, and armed robbery). These criminals have been defined as "habitual offenders," "professional criminals," "career criminals," and "serial offenders." The interest in these criminals is a rational one, given the perception that they present a severe threat to society. The main challenge in this area of research is a conceptual problem that has significant effects across the field. To this day, scholars have reused and misused titles to define and explain different concepts. The aim of this article is 3-fold. First, to review the concepts of criminal career, professional crime, habitual offenses, and seriality with a critical attitude on confusing terms. Second, to propose the redefinition of concepts mentioned previously, mainly on the criminal career. Third, to propose a theoretical model to enable a better understanding of, and serve as a basis for, further research in this important area of criminology. © The Author(s) 2015.

  10. Automated detection of multiple sclerosis lesions in serial brain MRI

    International Nuclear Information System (INIS)

    Llado, Xavier; Ganiler, Onur; Oliver, Arnau; Marti, Robert; Freixenet, Jordi; Valls, Laia; Vilanova, Joan C.; Ramio-Torrenta, Lluis; Rovira, Alex

    2012-01-01

    Multiple sclerosis (MS) is a serious disease typically occurring in the brain whose diagnosis and efficacy of treatment monitoring are vital. Magnetic resonance imaging (MRI) is frequently used in serial brain imaging due to the rich and detailed information provided. Time-series analysis of images is widely used for MS diagnosis and patient follow-up. However, conventional manual methods are time-consuming, subjective, and error-prone. Thus, the development of automated techniques for the detection and quantification of MS lesions is a major challenge. This paper presents an up-to-date review of the approaches which deal with the time-series analysis of brain MRI for detecting active MS lesions and quantifying lesion load change. We provide a comprehensive reference source for researchers in which several approaches to change detection and quantification of MS lesions are investigated and classified. We also analyze the results provided by the approaches, discuss open problems, and point out possible future trends. Lesion detection approaches are required for the detection of static lesions and for diagnostic purposes, while either quantification of detected lesions or change detection algorithms are needed to follow up MS patients. However, there is not yet a single approach that can emerge as a standard for the clinical practice, automatically providing an accurate MS lesion evolution quantification. Future trends will focus on combining the lesion detection in single studies with the analysis of the change detection in serial MRI. (orig.)

  11. Serial album validation for promotion of infant body weight control

    Directory of Open Access Journals (Sweden)

    Nathalia Costa Gonzaga Saraiva

    2018-05-01

    Full Text Available ABSTRACT Objective: to validate the content and appearance of a serial album for children aged from 7 to 10 years addressing the topic of prevention and control of body weight. Method: methodological study with descriptive nature. The validation process was attended by 33 specialists in educational technologies and/or in excess of infantile weight. The agreement index of 80% was the minimum considered to guarantee the validation of the material. Results: most of the specialists had a doctoral degree and a graduate degree in nursing. Regarding content, illustrations, layout and relevance, all items were validated and 69.7% of the experts considered the album as great. The overall agreement validation index for the educational technology was 0.88. Only the script-sheet 3 did not reach the cutoff point of the content validation index. Changes were made to the material, such as title change, inclusion of the school context and insertion of nutritionist and physical educator in the story narrated in the album. Conclusion: the proposed serial album was considered valid by experts regarding content and appearance, suggesting that this technology has the potential to contribute in health education by promoting healthy weight in the age group of 7 to 10 years.

  12. Forgetting in immediate serial recall: decay, temporal distinctiveness, or interference?

    Science.gov (United States)

    Oberauer, Klaus; Lewandowsky, Stephan

    2008-07-01

    Three hypotheses of forgetting from immediate memory were tested: time-based decay, decreasing temporal distinctiveness, and interference. The hypotheses were represented by 3 models of serial recall: the primacy model, the SIMPLE (scale-independent memory, perception, and learning) model, and the SOB (serial order in a box) model, respectively. The models were fit to 2 experiments investigating the effect of filled delays between items at encoding or at recall. Short delays between items, filled with articulatory suppression, led to massive impairment of memory relative to a no-delay baseline. Extending the delays had little additional effect, suggesting that the passage of time alone does not cause forgetting. Adding a choice reaction task in the delay periods to block attention-based rehearsal did not change these results. The interference-based SOB fit the data best; the primacy model overpredicted the effect of lengthening delays, and SIMPLE was unable to explain the effect of delays at encoding. The authors conclude that purely temporal views of forgetting are inadequate. Copyright (c) 2008 APA, all rights reserved.

  13. Automated detection of multiple sclerosis lesions in serial brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Llado, Xavier; Ganiler, Onur; Oliver, Arnau; Marti, Robert; Freixenet, Jordi [University of Girona, Computer Vision and Robotics Group, Girona (Spain); Valls, Laia [Dr. Josep Trueta University Hospital, Department of Radiology, Girona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain); Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Department of Radiology, Barcelona (Spain)

    2012-08-15

    Multiple sclerosis (MS) is a serious disease typically occurring in the brain whose diagnosis and efficacy of treatment monitoring are vital. Magnetic resonance imaging (MRI) is frequently used in serial brain imaging due to the rich and detailed information provided. Time-series analysis of images is widely used for MS diagnosis and patient follow-up. However, conventional manual methods are time-consuming, subjective, and error-prone. Thus, the development of automated techniques for the detection and quantification of MS lesions is a major challenge. This paper presents an up-to-date review of the approaches which deal with the time-series analysis of brain MRI for detecting active MS lesions and quantifying lesion load change. We provide a comprehensive reference source for researchers in which several approaches to change detection and quantification of MS lesions are investigated and classified. We also analyze the results provided by the approaches, discuss open problems, and point out possible future trends. Lesion detection approaches are required for the detection of static lesions and for diagnostic purposes, while either quantification of detected lesions or change detection algorithms are needed to follow up MS patients. However, there is not yet a single approach that can emerge as a standard for the clinical practice, automatically providing an accurate MS lesion evolution quantification. Future trends will focus on combining the lesion detection in single studies with the analysis of the change detection in serial MRI. (orig.)

  14. Serial sectioning methods for 3D investigations in materials science.

    Science.gov (United States)

    Zankel, Armin; Wagner, Julian; Poelt, Peter

    2014-07-01

    A variety of methods for the investigation and 3D representation of the inner structure of materials has been developed. In this paper, techniques based on slice and view using scanning microscopy for imaging are presented and compared. Three different methods of serial sectioning combined with either scanning electron or scanning ion microscopy or atomic force microscopy (AFM) were placed under scrutiny: serial block-face scanning electron microscopy, which facilitates an ultramicrotome built into the chamber of a variable pressure scanning electron microscope; three-dimensional (3D) AFM, which combines an (cryo-) ultramicrotome with an atomic force microscope, and 3D FIB, which delivers results by slicing with a focused ion beam. These three methods complement one another in many respects, e.g., in the type of materials that can be investigated, the resolution that can be obtained and the information that can be extracted from 3D reconstructions. A detailed review is given about preparation, the slice and view process itself, and the limitations of the methods and possible artifacts. Applications for each technique are also provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Improved Software to Browse the Serial Medical Images for Learning.

    Science.gov (United States)

    Kwon, Koojoo; Chung, Min Suk; Park, Jin Seo; Shin, Byeong Seok; Chung, Beom Sun

    2017-07-01

    The thousands of serial images used for medical pedagogy cannot be included in a printed book; they also cannot be efficiently handled by ordinary image viewer software. The purpose of this study was to provide browsing software to grasp serial medical images efficiently. The primary function of the newly programmed software was to select images using 3 types of interfaces: buttons or a horizontal scroll bar, a vertical scroll bar, and a checkbox. The secondary function was to show the names of the structures that had been outlined on the images. To confirm the functions of the software, 3 different types of image data of cadavers (sectioned and outlined images, volume models of the stomach, and photos of the dissected knees) were inputted. The browsing software was downloadable for free from the homepage (anatomy.co.kr) and available off-line. The data sets provided could be replaced by any developers for their educational achievements. We anticipate that the software will contribute to medical education by allowing users to browse a variety of images. © 2017 The Korean Academy of Medical Sciences.

  16. Volume imaging NDE and serial sectioning of carbon fiber composites

    Science.gov (United States)

    Hakim, Issa; Schumacher, David; Sundar, Veeraraghavan; Donaldson, Steven; Creuz, Aline; Schneider, Rainer; Keller, Juergen; Browning, Charles; May, Daniel; Ras, Mohamad Abo; Meyendorf, Norbert

    2018-04-01

    A composite material is a combination of two or more materials with very different mechanical, thermal and electrical properties. The various forms of composite materials, due to their high material properties, are widely used as structural materials in the aviation, space, marine, automobile, and sports industries. However, some defects like voids, delamination, or inhomogeneous fiber distribution that form during the fabricating processes of composites can seriously affect the mechanical properties of the composite material. In this study, several imaging NDE techniques such as: thermography, high frequency eddy current, ultrasonic, x-ray radiography, x-ray laminography, and high resolution x-ray CT were conducted to characterize the microstructure of carbon fiber composites. Then, a 3D analysis was implemented by the destructive technique of serial sectioning for the same sample tested by the NDE methods. To better analyze the results of this work and extract a clear volume image for all features and defects contained in the composite material, an intensive comparison was conducted among hundreds of 3D-NDE and multi serial sections' scan images showing the microstructure variation.

  17. Nonlinear Process Fault Diagnosis Based on Serial Principal Component Analysis.

    Science.gov (United States)

    Deng, Xiaogang; Tian, Xuemin; Chen, Sheng; Harris, Chris J

    2018-03-01

    Many industrial processes contain both linear and nonlinear parts, and kernel principal component analysis (KPCA), widely used in nonlinear process monitoring, may not offer the most effective means for dealing with these nonlinear processes. This paper proposes a new hybrid linear-nonlinear statistical modeling approach for nonlinear process monitoring by closely integrating linear principal component analysis (PCA) and nonlinear KPCA using a serial model structure, which we refer to as serial PCA (SPCA). Specifically, PCA is first applied to extract PCs as linear features, and to decompose the data into the PC subspace and residual subspace (RS). Then, KPCA is performed in the RS to extract the nonlinear PCs as nonlinear features. Two monitoring statistics are constructed for fault detection, based on both the linear and nonlinear features extracted by the proposed SPCA. To effectively perform fault identification after a fault is detected, an SPCA similarity factor method is built for fault recognition, which fuses both the linear and nonlinear features. Unlike PCA and KPCA, the proposed method takes into account both linear and nonlinear PCs simultaneously, and therefore, it can better exploit the underlying process's structure to enhance fault diagnosis performance. Two case studies involving a simulated nonlinear process and the benchmark Tennessee Eastman process demonstrate that the proposed SPCA approach is more effective than the existing state-of-the-art approach based on KPCA alone, in terms of nonlinear process fault detection and identification.

  18. Serial Contradictions. The Italian Debate on Tv Series

    Directory of Open Access Journals (Sweden)

    Daniela Cardini

    2016-06-01

    Full Text Available In the last decade the academic debate on television seriality has become lively and often quite animated, in the US as well as in Italy. The traditional hierarchic relation between cinema and television is clearly represented by the form of the most recent tv drama, whose boundaries are more and more difficult to locate. The main questions at stake seem to be the so-called “cinematic television” (Mills, 2013; Jaramillo, 2013, the umbrella definition of “quality tv” (McCabe and Akass, 2007 and its relation with the broadest concept of “complex tv” (Mittell, 2009, 2015. The essay will take into consideration these oxymorons, which are deeply rooted in the Italian tv series debate, with the aim of considering both their risks and their opportunities. A great variety of texts are grouped under the “tv series” label, but they are very different as far as content, production values and audience reactions are concerned. The academic discourse, however, only recently has tried to identify the differences between longstanding mainstream shows (such as, for instance, Grey’s Anatomy or CSI and some more recent, and supposedly “cinematic” series like True Detective or Fargo. Together with the analysis of the oxymoric nature of recent television seriality, the essay will explore the need to historicising what is proving to be one of the most dense and fruitful domains of recent television studies.

  19. Forgiveness and Suicidal Behavior: Cynicism and Psychache as Serial Mediators.

    Science.gov (United States)

    Dangel, Trever J; Webb, Jon R; Hirsch, Jameson K

    2018-02-17

    Research is burgeoning regarding the beneficial association of forgiveness with numerous health-related outcomes; however, its particular relationship to suicidal behavior has received relatively little attention. Both cynicism and psychache, or agonizing psychological pain, have displayed deleterious associations with suicidal behavior, but have rarely been incorporated into more comprehensive models of suicidal behavior. Consistent with the recent development of a theoretical model regarding the forgiveness-suicidal behavior association, the present study utilized an undergraduate sample of college students (N = 312) to test a mediation-based model of the cross-sectional association of forgiveness with suicidal behavior, as serially mediated by cynicism and psychache. Dispositional forgiveness of self and forgiveness of uncontrollable situations were each indirectly associated with less suicidal behavior via less psychache. Also, dispositional forgiveness of others was indirectly associated with less suicidal behavior via less cynicism and less psychache, in a serial fashion. The present results are consistent with the extent literature on the forgiveness-suicidal behavior association, cynicism, and psychache, and pending future studies, may be utilized to inform further treatment efforts for individuals at a high risk of attempting suicide.

  20. Blood transfusions

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000431.htm Blood transfusions To use the sharing features on this page, ... There are many reasons you may need a blood transfusion: After knee or hip replacement surgery, or other ...